HI 9912 HI 9923
the controller to avoid any interference and are user-switchable between 0 to 20 mA or 4 to 20 mA. HIGH IMPEDANCE INPUT The HI 9912 and HI 9923 controllers come with high impedance 1012 ohm direct input from the electrode, ideal for applications with a distance of up to 33 (10 meters). The greater the distance between the controller and the sample, the greater the chance that line noise will occur causing faulty readings. Using an
The modular design isolates electrical connections in a closed compartment while the control settings are accessible and can be made through the adjacent compartment.
Side View
HI 9912
HI 9923
Specifications Range Resolution Accuracy (@20C/68F) Typical EMC Deviation Calibration Hysteresis Setpoint Proportional Control Dead Band Dosing Contact
Alarm Relay
HI 9912 HI 9923 0.00 to 14.00 pH and 0 to 1000 mV 0.00 to 14.00 pH and 0.00 to 10.00 mS/cm (mmho/cm) 0.01 pH and 1 mV 0.01 pH and 0.01 mS/cm (mmho/cm) 0.02 and 5 mV 0.02 pH and 2% F.S. 0.1 pH and 6 mV 0.1 pH and 2% F.S. Two points for pH and one for ORP through trimmers on front panel Two points for pH and for conductivity through ZERO and SLOPE CAL trimmers EC adjustable from 0 to 0.5 mS/cm Selectable from 6.00 to 8.00 pH and 500 to 900 mV Selectable from 5.00 to 10.00 pH and 1.00 to 6.00 mS/cm Adjustable: pH from 0.0 to 2.0, mV from 0 to 200 and time cycles from 0 to 90 seconds From 0.0 to 0.5 mS/cm (mmho/cm) Two powered terminals for pH and ORP correction (115 or 240V) Two powered terminals for alkaline pH and EC correction (115 or 240V) max. 2 A, 1,000,000 strokes; activated proportionally if pH (0.0 to 2.0) and/or max. 2 A, 1,000,000 strokes ORP (0 to 200 mV) varies by more than the user selectable interval from the set point One, activated when pH varies (selectable 0.0 to 2.0) or ORP varies (0 to 200 mV) One, activated when pH exceeds (selectable 0 to 2.0) the set point or mS/cm drops below from the setpoint and/or max. dosage time (1 to 10 minutes) elapses. (selectable 0 to 2 mS) the setpoint and/or max. dosage time (1 to 90 minutes) elapses. Isolated, max 2 A, Max 240V, resistive load, 1,000,000 strokes Isolated, max 2 A, Max 240V, resistive load, 1,000,000 strokes 14 to 122F (-10 to 50C); max. RH 95% non-condensing 110/115V or 220/240V; 50/60 Hz Fiber-reinforced, self-extinguishing ABS. 181L x 221W x 142H mm (7.1L x 8.7W x 5.6H) 3.5 lb. (1.6 Kg) Recommended Accessories HI 6101405 . . . . . . . . . . . . .Amplified Flat-tip combination pH electrode with matching pin, 5 m (16.5) cable, & BNC connector HI 6200405 . . .Amplified Flat-tip platinum combination ORP electrode with matching pin, 5 m (16.5) cable, & BNC connector HI 1002/5 . . . . . . . . . . . .Combination pH electrode with 16.5 (5 m) cable HI 2002/5 . . . . . . . . . . . . . . . . . .ORP Pt electrode with 16.5 (5 m) cable HI 3001D . . . . . . . . . . . . . . . . . . . . . . . . . . . .In-line conductivity/C probe HI 7004L . . . . . . . . . . . . . . . . . . . . . . . . .pH 4.01 buffer solution, 500 mL Hanna solutions are available in different sizes to fit any application. HI HI HI HI HI HI HI HI HI HI 7007L . . . . . . . . . . . . . . . . . . . . . . . . .pH 7.01 buffer solution, 500 mL 7010L . . . . . . . . . . . . . . . . . . . . . . . .pH 10.01 buffer solution, 500 mL 7020L . . . . . . . . . . . . . . . . .ORP testing solution 200/275 mV, 500 mL 7091L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Reducing solution, 500 mL 7031L . . . . . . . . . . . . . . . . .1413 S/cm conductivity solution, 460 mL 7039L . . . . . . . . . . . . . . . . .5000 S/cm conductivity solution, 460 mL 7092L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Oxidizing solution, 500 mL 70300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Storage solution, 460 mL 8427 . . . . . . . . . . . . . . . . . . . . . . . . . . .pH and ORP electrode simulator 931001 . . . . . . . . . . . . . . . . . . . . . . . . .pH and ORP electrode simulator
Ordering Information HI 9912 pH and ORP controller. HI 9923 pH and Conductivity controller.
www.hannainst.com
Conductivity Probes
HI 1002/5 HI 2002/5
Combination pH & ORP electrodes
HI 3001
Flow-thru Probe
(HI 2002/5)
Specifications Temp. Comp. Body Material Working Temperature Max Pressure (@25C/77F)
HI 7638
Submersion/in-line Conductivity Probe
Specifications Reference System Junction Type Electrolyte Temperature Max Pressure Lead Connector Cable
HI 1002/5 (pH) HI 2002/5 (ORP) Double Teflon Polymer 23 to 176F (-5 to 80C) 87 psi (6 bar) BNC 16.5 (5 m)
Specifications Temp. Comp. Body Material Working Temperature Max Pressure (@25C/77F)
HI 6101405
Amplified combination flat-tip pH electrode
HI 6200405
Amplified combination flat-tip platinum ORP electrode
Specifications Reference System Junction Type Electrolyte Temperature Max Pressure Lead Connector Cable
Specifications Reference System Junction Type Electrolyte Temperature Max Pressure Lead Connector Cable
Authorized Distributor:
ISO
Certified
9001
Hanna Instruments Water Analysis & Control Division 43180 Business Park Drive, Suite A-201, Temecula, CA 92590 Tel.: