TTA LDCE QUESTION BANK 2012 DEPARTMENTAL PRACTICES

Question Bank - 1 1. SPC exchanges means a) Stored Programme Controlled Exchange b) Subscribers Private Controlled Exchange c) Special Programme Controlled Exchange d) Stored Programme Connected Exchange 2. The battery eliminator used in Plan 103 instrument requires electricity of a) 12V c) 415V b) 50V d) 230V 3. _____________ is used to check the specific gravity of electrolyte of the secondary cells. a) Lacto meter c) Ammeter b) Hydrometer d) Potentiometer 4. Specific gravity of the electrolyte should be a) 1000 b) 1200 c) 800 d) 100

5. Potential difference of a single cell installed in Battery room a) 2V c) 2.25V b) 3V d) 2.5V 6. Transformer used in Float- Rectifier a) Mini Transformer b) Step-Down Transformer

c) Step-Up Transformer d) Both Step-Down And Step-up

7. Voltage regulation in Float rectifier is carried out by a) Zener Diode c) SC Diode b) Junction Diode d) Photo Diode 8. Capacity of battery is expressed in a) Ampere b) Watt 9. Potential difference of a cell is measured by a) Ammeter b) Multi-meter

c) Volt d) Ampere Hour

c) Hydrometer d) Aplab Meter

10.The C-DOT (RAX) has a capacity of ----------- terminations a) 256 c) 1024 b) 512 d) None

11.In CDOT Exchanges LCC/CCB/CCM are a) Service Cards b) Subscriber Line Cards 12.In C-DOT RAP/RSC/SPC are a) Controller Cards b) Service Cards 13. 16 KHZ pulse generated in a) LCC card b) CCM card 14. Electrolyte used in secondary cells a) Diluted Sulphuric Acid b) Hydrochloric Acid

c) Controller Cards d) None

c) Subscribers Line Cards d) None

c) CCB card d) Controller card

c) Distilled Water d) None

15.One main and two internal extensions available in a) Plan 101 c) Plan 103 b) Plan 102 d) Plan 104 16.In E10B XEJ card ----------- subscribers can be terminated a) 8 c) 10 b) 16 d) 32 17.In Plan 103 the extension speech wire and buzzer wire a) are the same c) cannot be interchanged b) can be interchanged d) not available 18.For earthing, the metal of the wire, and the plate should be a) Same c) G.I Wire b) Different d) None 19.If exchange earth and tower earth are installed in the same building a) Both earth value should be the same b) Tower earth ohmic value should be less than exchange earth c) Exchange earth value should be less than tower earth d) None. 20.Output voltage of Float Rectifier should be ________ out put voltage of Battery a) Higher than c) Equal to b) Lower than d) 1/3 of 21._______________ is used to find earth resistance a) Ammeter c) Meggar d) Multimeter b) Aplap

22.IOP is basically handles all the input and out put functions in a) E10B c) 5ESS b) EWSD d) CDOT 23.UY connectors are used for jointing a) Jelly Filled Cable b) Paper Core Cable

c) OF Cable d) Switch Board Cable

24.------------ is used to remove sleeve of the conductor of U/G cable a) Cutting Plier c) Krone Tool b) Nose Plier d) Osatool 25.Inter communication is possible in ----- plan instrument a) 101 c) 104 b) 102 d) None 26.When the extension is external ---------- plan is used. a) 104 c) 102 b) 103 d) 101 27.Noise voltage is measured by a) Voltmeter b) Hydrometer 28.PCM means a) Pulse Communication Mode b) Phased Carrier Module

c) Ammeter d) Psophometer

c) Pulse Current Mode d) Pulse Code Modulation

29.One set of battery in a telephone Exchange will have ------- number of secondary cells a) 12 c) 20 b) 24 d) 16 30.The tool used for jointing jelly filled under ground cable conductors with UY connector is a) Crimping tool c) Osa tool b) Krone tool d) Connecting tool 31.Which one of the following is in correct ascending order a) TM,RM,TTA,SDE,JTO,AGM c) DGM,AGM,SDE,GM,PGM,CGM b) TTA, JTO, SDE, DE, DGM, GM d) SDE,AGM,DGM,CGM,PGM 32.ISDN stands for a) Integrated Services Digital Network b) Inter Services Digital Network c) Integrated Switch Digital Network d) Internal Services Digital Network

33.PSTN stands for a) Pocket Switched Telephone Network b) Public Switched Telephone Network c) Public Switched Trunk Network d) Private Switched Telephone Network 34.Which one of the following is not an electronic Exchange a) 5ESS c) EWSD b) C-DOT d) STROWGER 35.Pick the odd one out a) AXE10 b) 5ESS 36.AN-RAX is related to a) E10B b) C-DOT

c) C-DOT d) OCB283

c) OCB283 d) 5ESS

37.Which one of the following statement is not true? Access Network Rural Automatic Exchange (AN RAX) a) will provide the second level of remoting b) may be connected to RSU or directly to the local exchange c) Support V 5.2 protocol d) Is not able to handle call processing, charging and billing functionality 38.In ____________Exchange system CCS7 signaling and ISDN cannot be used. a) AXE10 c) E10B b) OCB283 d) EWSD 39.The most effective and practical method of reducing cross talk is a) Wire Configuration c) Resistance Unbalance b) Transpositions d) None 40.____________ is of paramount importance to effect the transfer of maximum energy from one telecom network into another a) Impedance matching c) Reduction of cross talk b) Transposition d) Reducing transmission loss 41.For temporary splicing of optical fibre cable in case of emergency ___ method is used a) Glue Splicing c) Fusion Splicing b) Mechanical Splicing d) None 42.WLL stands for a) Wireless in local line b) Wireless in line loop c) Wireless in local loop d) Wiring in local loop

43.MLLN stands for a) Managed Leased Line Network b) Managed Local Line Network c) Maintenance of Leased Line Network d) Multipoint Leased Line Network 44.Gauge of conductor of commonly used jelly filled U/G cable is a) 0.40 mm c) 0.63 mm b) 0.50 mm d) 0.90 mm 45.PIJF cables stands for a) Protected Insulated Jelly Filled b) Polythene Insulated Jelly Filled

c) Polymer Insulation Jelly Filled d) Primary Insulated Jelly Filled

46.Primary colours of JF cable conductors identification. Which one is not correct? a) White c) Brown b) Red d) Yellow 47.Secondary colors of JF cable pair identification. Which one is not correct? a) Blue d) Slate b) Black e) Green c) Orange 48.PTTC stands for a) Private Telecommunication Coordination Committee b) Power Telecommunication Cooperation Committee c) Power Telecommunication Coordination Committee d) Public Telecommunication Coordination Committee 49.When the insulation between conductor in the cable falls below 0.5 meg Ohms, the fault is known as a) Low insulation fault c) Foreign potential b) Disconnection fault d) Short circuit fault 50.The exchange earth resistance should not normally exceed________ ohms at any time for the year a) 5 c) 0.1 b) 2 d) 0.2

ANSWERS: