BURNDY

Telecommunications Products
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Small Hydent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Small Hylug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
One Hole Hylug Code Conductor
Standard Barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Standard Barrel Narrow Tongue . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Long Barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Long Barrel With Inspection Window . . . . . . . . . . . . . . . . . . . . . . . .46
One Hole Hylug Flex Conductor
Standard Barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Standard Barrel Belled End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Standard Barrel Lead Plated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Long Barrel Belled End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Long Barrel With Inspection Window . . . . . . . . . . . . . . . . . . . . . . . .65
Two Hole Hylug Code Conductor
Standard Barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Standard Barrel Narrow Tongue . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Long Barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Long Barrel With Inspection Window . . . . . . . . . . . . . . . . . . . . . . . .82
Two Hole Hylug Flex Conductor
Standard Barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
Standard Barrel Lead Plated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Long Barrel Belled End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
Long Barrel With Inspection Window . . . . . . . . . . . . . . . . . . . . . . .105
Split Barrel Hylug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Two Hole Hylug Flex Conductor Double Barrel . . . . . . . . . . . . . . . . . . . . . .110
Type CUSA Hystack Terminal Stacking Adaptor . . . . . . . . . . . . . . . . . . . . . . . .111
Splices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Taps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Separable Power Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
Cable Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211
Installation Tooling System Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219

BURNDY
Telecommunications Products
BURNDY
Telecommunications
Connectors
The industrys first choice in
compression connections...
BURNDY provides a complete selection of
one and two hole compression terminals,
H-taps, C-taps, and other compression connection products specifically engineered to
meet the demanding applications of both the
Central Office and Wireless communications
markets.
All of BURNDYs compression products are
designed for reliable and controllable
electrical connections. All connectors are
made from high conductivity electrolytic
copper and operate at cooler temperatures
than the conductor on which they are
installed. The connectors are normally
tin-plated, lead-plated, or plated with a proprietary BURNDY brite finish to provide the
industry standard in long-lasting corrosion
resistance.
The complete installation is fully inspectable
and UL listed when installed with BURNDY
dies. Every die in the system is color-coded
and provides die index embossment for
complete inspectability.

The Circumferential Crimp

Circumferential compression is solid


and symmetrical. No sharp "Flash".

BURNDYs circumferential crimp provides a


solid, homogenous connection, with high pull
out values and is rated for high voltage applications, more than sufficient for the 48 V DC
operating voltage common in the telecom
market. In addition, the circumferential crimp
doesnt require the removal of the copper
flash produced by other die systems. This not
only saves time in installation but removes a
potential safety hazard from the job.
All of the dies in the system are color-coded
to match the connectors and feature die index
and die number matching to the connector for
ease of installation.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY Tooling
the right choice for the job
BURNDY tooling installs a wide range of
connectors, is reliable, cost effective, and precision engineered for durable, long-lasting
service and quality connections. BURNDYs
compression tooling system ranges from full
cycle ratchet hand tools to 12- and 15-ton
hydraulically-powered HYPRESS heads.
Hydraulic tools are available in selfcontained, battery powered, and AC service
electrically powered pump and remote head
designs to meet all possible installation situations.

Industry Standards
BURNDYs compression terminals, splices
and tap connectors requiring third party
testing and approval are listed by Underwriters
Laboratories, Inc. Many have also received
CSA approval, and all conform to the applicable sections of the National Electric Code.

BURNDY
Telecommunications Products
TYPES TP AND BA

WIRE
CRIMP

EXPANDED SHROUD
INSULATION CRIMP

VINYLUG
TERMINAL
POLYVINYLCHLORIDE
INSULATED, RING TONGUE

COLOR CODED
INSULATION
WIRE SIZE
RANGE

600 VOLTS MAX. 105 C MAX.


VINYLUG Type TP is designed for commercial and light duty industrial control and power
circuit applications. Supplied with an expanded
polyvinyl chloride (PVC) insulation shroud,
many tongue variations and rated 600V
makes TP terminals versatile and economical.

CATALOG
NUMBER
TP16-4
TP16-6
TP16-8
TP16-10
TP16-14
TP16-38
TP14-4
TP14-6
TP14-8
TP14-10
TP14-14
TP14-516
TP14-38
TP10-6
TP10-8
TP10-10
TP10-14
TP10-38

WIRE
RANGE
22-16
Max. Insul.
Dia. Accom.: .145
Color Code:
Red
16-14
Max. Insul.
Dia. Accom.: .180
Color Code:
Blue
12-10
Max. Insul.
Dia. Accom.: .260
Color Code:
Yellow

STUD
SIZE

3-4
4-6
6-8
8-10
12, 1/4
3/8
3-4
4-6
6-8
8-10
12, 1/4
5/16
3/8
4-6
6-8
8-10
12, 1/4
3/8

.22
.25
.31
.31
.40
.53
.22
.25
.31
.31
.40
.53
.53
.31
.36
.36
.53
.53

SMOOTH
ENTRY

RING
TONGUE

TIN
PLATED

DEEP V
SERRATIONS

Features and Benefits


Expanded insulation support accepts
standard and large wire diameters.
Lowers inventory requirements,
permits greater flexibility and provides
insulation support.
Funnel entry.
Easy wire insertion.
Manufactured of pure electrolytic copper.
Provides maximum conductivity, low
resistance and ductility for excellent
crimp forming properties.

DIMENSIONS
L
Y
.71
.74
.85
.85
.99
1.15
.71
.74
.85
.85
.99
1.15
1.15
.91
1.00
1.00
1.22
1.27

.61
.62
.70
.70
.79
.88
.61
.62
.70
.70
.79
.88
.88
.75
.81
.81
.95
1.00

BULK
CATALOG
NUMBER*

.17
.18
.26
.26
.36
.45
.17
.18
.26
.26
.36
.45
.45
.20
.26
.26
.40
.45

BA16E4
BA16E6
BA16E8
BA16E10
BA16E14
BA16E38
BA14E4
BA14E6
BA14E8
BA14E10
BA14E14
BA14E516
BA14E38
BA10E6
BA10E8
BA10E10
BA10E14
BA10E38

Deep V groove serrations in the


inner barrel.
Provides added holding strength and
better conductivity.
Electro-tin plated.
Provides durable long-lasting
corrosion resistance.

INSTALLATION
TOOLING

Plier Type:
Y10-22, Y10D
or
Ratchet Tool:
MR8-89-1,
MR8-G96,
MR15

Plier Type:
Y10-22, Y10D
or Ratchet:
MR8-89-1,
MR15

TAPE MOUNTED
WIRE
CATALOG NO. INSTALLATION STRIP
2000/Reel
TOOLING
LENGTH
BA16E4M
BA16E6M
BA16E8M
BA16E10M
BA16E14M
BA16E38M
BA14E4M
BA14E6M
BA14E8M
BA14E10M
BA14E14M
BA14E516M
BA14E38M
*BA10E6M
*BA10E8M
*BA10E10M
*BA10E14M
*BA10E38M

TFM
with
DFM3D-1
Die

13/64

TFM
with
DFM2D-1
Die

13/64

TFM
with
DFM1D5
Die

19/64

* 1000/Reel

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES TN, YAES

Features and Benefits

INSULUG
TERMINAL
NYLON INSULATED,
RING-TONGUE
300 VOLT MAX. 105C MAX.
INSULUG type TN Nylon-insulated terminals are designed for heavy duty industrial,
utility and military power and control-circuit
applications for wire sizes 26 AWG through
10 AWG. They offer high dielectric strength
and stability in oily conditions and meet military CLASS 1 and CLASS 2 requirements per
MS25036 and the requirements of military
specifications MIL-T-7928 (ASG).

DEEP "V"
SERRATIONS

An integral one-piece copper barrel/insulation grip and wire strain relief design.
Provides improved physical strength
characteristics over a multi-piece design.
Manufactured of pure electrolytic copper.
Provides maximum conductivity, low
resistance and ductility for excellent
crimp forming properties.
Brazed seam.
Provides a stronger barrel design to
minimize any possible splitting and
eliminates folding.
Deep inner barrel serrations.
Provides excellent electrical conductivity
and pullout strength values.

Smooth funnel entry.


Easy wire insertion.
The insulation is locked in place.
Will not twist off, thereby maintains
proper dielectric values.
Electro-tin plated.
Provides durable long-lasting resistance
to corrosion.
Color-coded and clearly marked.
Provides a secure termination under the
screw head that can not be removed
without complete removal of the screw.
Two or more terminals may be stacked on
a common stud easily.
Provides flexibility and versatility.

COLOR CODED
NYLON INSULATION
SMOOTH
FUNNEL ENTRY

INTEGRAL
ONE PIECE
COPPER,
TIN PLATED
DESIGN

INTEGRAL INSULATION
SUPPORT AND WIRE
STRAIN RELIEF
WIRE SIZE
AND STUD SIZE

CATALOG
NUMBER
TN18-4
TN18-6
TN18-8
TN18-10
TN18-14
TN18-516
TN18-38
TN14-4
TN14-6
TN14-8
TN14-10
TN14-14
TN14-516
TN14-38
TN10-6
TN10-8
TN10-10
TN10-14
TN10-516
TN10-38

WIRE
RANGE
22-18
Max. Insul.
Dia. Accom.: .120
Color Code:
Red

16-14
Max. Insul.
Dia. Accom.: .153
Color Code:
Blue
12-10
Max. Insul.
Dia. Accom.: .210
Color Code:
Yellow

STUD
SIZE

MIL. STD.
MS25036-

3-4
4-6
6-8
8-10
12, 1/4
5/16
3/8
3-4
4-6
6-8
8-10
12, 1/4
5/16
3/8
4-6
6-8
8-10
12, 1/4
5/16
3/8

-148
-102
-149
-103
-150
-104
-105
-152
-106
-153
-108
-154
-109
-110
-111
-156
-112
-157
-113
-114

.23
.25
.31
.31
.46
.46
.53
.25
.25
.31
.31
.45
.45
.53
.37
.37
.37
.53
.53
.58

For CUSTOMER SERVICE call 1-800-346-4175

DIMENSIONS
L MAX. Y MAX.
.76
.87
.91
.91
1.09
1.09
1.17
.79
.79
.89
.89
1.08
1.08
1.16
1.12
1.12
1.12
1.32
1.32
1.34

.64
.74
.76
.76
.87
.87
.91
.67
.67
.74
.74
.86
.86
.90
.94
.94
.94
1.06
1.06
1.05

Z MAX.

BULK
CAT. NO.

.20
.29
.29
.29
.41
.41
.45
.24
.24
.31
.31
.43
.43
.47
.26
.26
.26
.37
.37
.40

YAES18N48
YAES18N1
YAES18N49
YAES18N3
YAES18N50
YAES18N4
YAES18N5
YAE14N52
YAES14N6
YAES14N53
YAES14N8
YAES14N54
YAES14N9
YAES14N10
YAES10N11
YAES10N56
YAES10N12
YAES10N57
YAES10N13
YAES10N14

INSTALLATION
TOOLING

WIRE
STRIP
LENGTH

7/32
Non-Ratchet:
Y10D,
Y1022

7/32

Ratchet:
MR8-83

11/32

BURNDY
Telecommunications Products
TYPES YAE-G BOX
AND YAE-N BOX

DEEP "V"
SERRATIONS

INSULUG

TIN PLATED
INSULATION
CRIMP

TERMINAL
NYLON INSULATED,
RING-TONGUE

INSULUG Type YAE-N and YAE-G nylon


insulated terminals are designed with a multifinger insulation grip for paper, EPR and other
elastic or hard to grip insulations. The metal
fingers firmly grip the insulation providing
superior holding characteristics, cable support and strain relief. Type YAE-N and YAE-G
terminals are rated 105C and meet military
standard MS25036 class 2 and MIL-T-7928
(ASG) requirements.

YAE22G18 BOX
26-20
YAE22G12 BOX Max. Insul.
YAE22G16 BOX Dia. Accom.:
YAE22G13 BOX
.098
YAE22G14 BOX Color Code:
YAE22G15 BOX
Amber

RING TONGUE

Features and Benefits

300 VOLT MAX. 105 C MAX.

WIRE
RANGE

COLOR CODED
NYLON INSULATION

WIRE SIZE
RANGE

MULTI-FINGER
INSULATION GRIP

CATALOG
NUMBER

MULTI-FINGER
INSULATION GRIP

WIRE CRIMP

Multi-finger insulation grip.


Provides superior insulation holding
characteristics, especially on EPR
and other elastic-type insulations.
Brazed seam.
Provides stronger more durable
termination.
Manufactured of pure electrolytic copper.
Provides maximum conductivity, low
resistance and ductility for excellent
crimp forming properties.

STUD
SIZE

MIL.
STD.**
MS25036

1-2
1-2
3-4
4-6
6-8
8-10

-148

-144
-145
-146
-147

.15
.25
.18
.25
.32
.32

DIMENSIONS
L
Y
MAX. MAX.
.70
.75
.75
.75
.83
.83

.62
.62
.62
.62
.67
.67

Z
MAX.
.22
.22
.22
.22
.27
.27

Deep V groove, inner barrel serrations.


Provide optimum conductivity, reliability,
and holding power.
Smooth funnel entry.
Easy wire insertion.

BULK
TAPE MOUNTED
WIRE
CATALOG INSTALLATION CATALOG NO. INSTALLATION STRIP
NUMBER*
TOOLING
2000/Reel
TOOLING
LENGTH
YAE22G18
YAE22G12
YAE22G16
YAE22G13
YAE22G14
YAE22G15

M8ND
with
N14HET-25V1
Die

YAE22G18M
YAE22G12M
YAE22G16M
YAE22G13M
YAE22G14M
YAE22G15M

TFM
with
DFM11D1
Die

5/32

Not UL recognized

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES YAE-G BOX
AND YAE-N BOX
(Continued)

CATALOG
NUMBER
YAE18N29 BOX
YAE18N27 BOX
YAE18N7 BOX
YAE18N17 BOX
YAE18N26 BOX
YAE18N21 BOX
YAE18N25 BOX
YAE18G43 BOX
YAE18N24 BOX
YAE18N1 BOX
YAE18N BOX

WIRE
RANGE

22-16
Max. Insul.
Dia.
Accom.: .125
Color Code:
Red

YAE18N2 BOX
YAE18N3 BOX
YAE14N43 BOX
YAE14N1 BOX
YAE14N BOX
YAE14N2 BOX
YAE14N3 BOX
YAE14N4 BOX
YAE12N7 BOX
YAE12N9 BOX
YAE12N1 BOX
YAE12N BOX
YAE12N2 BOX

16-14
Max. Insul.
Dia.
Accom.: .156
Color Code:
Blue
14-12
Max. Insul.
Dia.
Accom.: .180
Color Code:
Green

YAE10N5 BOX
YAE10N11 BOX
YAE10N BOX
YAE10N3 BOX
YAE10N2 BOX
YAE10N4 BOX

12-10
Max. Insul.
Dia.
Accom.: .209
Color Code:
Yellow

STUD
SIZE

MIL STD.**
MS25036

Z MIN.

BULK
CATALOG
NUMBER

1-2
2
4
4
4
4-6
4-6
4-6
6-8
6-8
8-10
12,
1/4
5/16
4-6
6-8
8-10
1/4
5/16
3/8
10
6-8
6-8
8-10

-148

-102

-149
-103

.14
.19
.25
.25
.23
.25
.22
.25
.28
.31
.31

.75
.77
.80
.80
.78
.89
.79
.90
.92
.92
.92

.68
.66
.68
.68
.68
.77
.68
.68
.77
.77
.77

.19
.19
.19
.19
.19
.28
.19
.19
.28
.28
.28

YAE18N29
YAE18N27
YAE18-N7
YAE18N17
YAE18N26
YAE18N21
YAE18N25
YAE18G43
YAE18N24
YAE18N1
YAE18N

-150

.45

1.11

.88

.40

YAE18N2

-104
-106
-153
-108
-154
-109
-110

.45
.25
.31
.31
.45
.45
.53
.31
.31
.31
.31

1.11
.82
.92
.92
1.11
1.11
1.19
1.06
1.06
1.06
1.06

.88
.69
.75
.75
.88
.88
.93
.93
.90
.90
.90

.40
.20
.28
.28
.40
.40
.44
.29
.28
.28
.28

YAE18N3
YAE14N43
YAE14N1
YAE14N
YAE14N2
YAE14N3
YAE14N4
YAE12N7
YAE12N9
YAE12N1
YAE12N

1/4

.46

1.25

1.02

.40

YAE12N2

4-6

-111

.38

1.15

.96

.28

YAE10N5

DIMENSIONS
L MAX. Y MAX.

6-8

-156

.38

1.17

.98

.30

YAE10N11

8-10

-112

.38

1.15

.96

.28

YAE10N

1/4

-157

.54

1.39

1.12

.44

YAE10N3

5/16

-113

.54

1.39

1.12

.44

YAE10N2

3/8

-114

.54

1.39

1.12

.44

YAE10N4

TAPE
MOUNTED
INSTALLATION CATALOG NO.
TOOLING
2000/REEL

MR8-33T-1
(no extra dies
required)
M8ND
with one of
following dies:
N14HET-25V1
N10ET-9
N14HET-15
or
Y10D
Y10-22

MR8-33T-1
(no extra dies
required)
Y10D
M8ND
with die N12HET-1
MR8-33T-1
(no extra dies
required)
M8ND with one of
the following dies:
N10HET-15
N10ET-9
Y10D, Y10-22

YAE18N29M
YAE18N27M
YAE18-N7M
YAE18N17M
YAE18N26M
YAE18N21M
YAE18N25M
YAE18G43M
YAE18N24M
YAE18N1M
YAE18NM

INSTALLATION
TOOLING

WIRE
STRIP
LENGTH

TFM
with
DFM10D1
die

3/16

TFM
with
DFM9D1
die

3/16

YAE18N2M
YAE18N3M
YAE14N43M
YAE14N1M
YAE14NM
YAE14N2M
YAE14N3M
YAE14N4M
YAE12N7M
YAE12N9M
YAE12N1M
YAE12NM
YAE12N2M
* YAE10N5M
* YAE10N11M
* YAE10NM
* YAE10N3M

21/64
TFM
with
DFM7D1
die
3/8

* YAE10N2M
* YAE10N4M

* 1000/Reel
** Class 2
Use Y10D or Y10-22 only when crimping #16 AWG.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES YAEV
AND YAEV-L

COLOR CODED
NYLON INSULATION

INSPECTION
HOLE
RING
TONGUE

INSULUG

SEAMLESS
BARREL

TERMINAL
NYLON INSULATED
RING-TONGUE

DOUBLE THICK
TONGUE

TIN PLATED

300 VOLT MAX. 105 C MAX.

Features and Benefits

The INSULUG type YAEV is designed for


very demanding high vibration applications
encountered in aircraft and aboard ships as
well as motor lead applications in hospitals,
industrials and generating plants. The nylon
insulated seamless, electrolytic copper barrel
with double thick tongue provides an extra
strong insulated connection. The terminal
is rated 105C and meets MIL-T-7928
requirements.

Double thick tongue.


Provides maximum reliability and
electrical capacity plus an extra strong
terminal tongue.
Manufactured from one-piece pure
electrolytic copper.
Provides high conductivity, low resistance with no seams to split plus ductility
for excellent crimp forming properties.
Electro-tin plated.
Provides long-lasting corrosion
resistance.

CATALOG
NUMBER
YAEV18 BOX

YAEV14 BOX
YAEV10-T7 BOX
YAEV10-T11 BOX
YAEV10 BOX
YAEV10-L36 BOX
YAEV10-T3 BOX
YAEV10-T2 BOX
YAEV10-T4 BOX

WIRE RANGE
AWG AN
AIRCRAFT
22-18
Max. Insul.
Dia. Accom.: .125
Color Code: Red
18-14
Max. Insul.
Dia. Accom.: .154
Color Code: Blue
12-10
Max. Insul.
Dia. Accom.: .209
Color Code:
Yellow

DIMENSIONS
Z MIN.
Y MAX.

Nylon insulation is locked in place.


Insulation will not move or twist off.
300 volt nylon insulation
High dielectric strength and stability
in demanding oily environmental
conditions.
Color coded.
Provides quick, easy wire size
connector selection.

BULK
CATALOG
NUMBER

MS25036-*
DASH NO.

8-10

.31

.24

.77

.91

YAEV18

Ratchet:
MR8D94

1/4

8-10

.31

.24

.88

.94

YAEV14

Ratchet:
MR18,
MR8D94

1/4

4-5
6-8
8-10
8-10
1/4
5/16
3/8

.30
.37
.37
.30
.47
.53
.56

.24
.26
.26
.18
.38
.31
.35

.95
.97
.97
.89
1.12
1.12
1.12

1.09
1.14
1.14
1.04
1.30
1.30
1.35

YAEV10-T7
YAEV10-T11
YAEV10
YAEV10-L36
YAEV10-T3
YAEV10-T2
YAEV10-T4

Ratchet:
MR8D94
MR8-33-T1
M8ND
with N10ET-9 DIE
MR18*
MR4 10M

5/16

L MAX.

INSTALLATION
TOOLING

WIRE
STRIP
LENGTH

STUD
SIZE

* # 10 Str. Cu. only.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES YAEV
AND YAEV-L
(Continued)
INSULUG
CATALOG
NUMBER

WIRE RANGE

YAEV8C-L14 BOX

STUD MS25036
SIZE DASH NO.

DIMENSIONS
Z MIN. Y MAX. L MAX.

BULK
CATALOG
NUMBER

6-8

.41

.28

1.20

1.40

YAEV8C-L14
YAEV8C-L

YAEV8C-L BOX

8 Str.

8-10

-115

.41

.28

1.20

1.40

YAEV8C-L1 BOX

Max. Insul.

1/4

-116

.46

.33

1.24

1.47

YAEV8-L1

YAEV8C-L2 BOX

Dia. Accom.: .258

5/16

-117

.57

.35

1.28

1.55

YAEV8C-L2

YAEV8C-L3 BOX

Color Code: Red

YAEV8C-L4 BOX

6 Str.
Max. Insul.
Dia. Accom.: .313
Color Code:
Blue
4 Str.
Max. Insul.
Dia. Accom.: .374
Color Code:
Yellow
2 Str.
Max. Insul.
Dia. Accom.: .459
Color Code:
Red
1 Str.
Max. Insul.
Dia. Accom.: .516
Color Code:
White
1/0 Str.
Max. Insul.
Dia. Accom.: .564
Color Code:
Blue
2/0 Str.
Max. Insul.
Dia. Accom.: .628
Color Code:
Yellow

3/8

-118

.57

.35

1.39

1.55

YAEV8C-L3

1/2
8-10
1/4
5/16
3/8
1/2
8-10
1/4
5/16
3/8
1/2
10
1/4
5/16
3/8
1/2
1/4

-119**
-120**
-121**
-122**

-123
-124
-125

-126

-127
-128
-129

.73
.48
.48
.60
.60
.73
.55
.55
.63
.63
.73
.69
.69
.69
.69
.77
.76

.47
.29
.29
.36
.36
.47
.28
.28
.34
.34
.47
.35
.35
.35
.35
.47
.38

1.39
1.33
1.33
1.39
1.39
1.53
1.40
1.37
1.43
1.43
1.56
1.72
1.61
1.68
1.69
1.80
1.63

1.75
1.56
1.56
1.68
1.68
1.91
1.62
1.62
1.74
1.74
1.92
2.03
2.03
2.03
2.03
2.16
2.14

YAEV8C-L4
YAEV6C-L1**
YAEV6C-L**
YAEV6C-L4**
YAEV6C-L2**
YAEV6C-L10
YAEV4C-L3
YAEV4C-L
YAEV4C-L4
YAEV4C-L2
YAEV4C-L5
YAEV2C-L3
YAEV2C-L1
YAEV2C-L2
YAEV2C-L
YAEV2C-L4
YAEV1C-L1

5/16
3/8
1/2
1/4
5/16
3/8
1/2
5/8
1/4
5/16
3/8
1/2
5/8

-130
-131
-132

-133
-134

-135
-136
-137

.76
.76
.86
.83
.83
.83
.88
.88
.93
.93
.93
.93
.93

.38
.38
.47
.43
.43
.43
.47
.63
.49
.49
.49
.49
.63

1.71
1.72
1.86
1.97
1.97
1.97
2.02
2.17
2.19
2.19
2.19
2.27
2.43

2.14
2.14
2.27
2.40
2.40
2.40
2.46
2.67
2.72
2.72
2.72
2.72
2.72

YAEV1C-L2
YAEV1C-L
YAEV1C-L3
YAEV25-L1
YAEV25-L2
YAEV25-L
YAEV25-L3
YAEV25-L4
YAEV26-L1
YAEV26-L2
YAEV26-L
YAEV26-L3
YAEV26-L12

INSTALLATION
TOOLING
Ratchet:
M8ND with
N8CET-2 Die
Non-Ratchet:
MY28-6*
Hydraulic:
Y35, Y39 with
U8CET Die Set
Non-Ratchet:
MY28-6*
Hydraulic:
Y35, Y39 with
U6CET Die Set
Non-Ratchet:
MY28-6*
Hydraulic:
Y35, Y39 with
U4CET Die Set
Non-Ratchet:
MY28-6*
Hydraulic:
Y35, Y39 with
U2CET Die Set
Non-Ratchet:
MY28-6*
Hydraulic:
Y35, Y39 with
U1CET Die Set
Non-Ratchet:
MY28-6*
Hydraulic:
Y35, Y39 with
U25ET Die Set
Non-Ratchet:
MY28-6*
Hydraulic:
Y35, Y39 with
U26ET Die Set

WIRE
HYPRESS Y29NC
STRIP
NEST INDENTOR LENGTH

DEV8L

7/16

Y29PLE-1
DEV6L

1/2

DEV4L

1/2

DEV2L

5/8

DV26L

5/8
Y29PLE

DEV25L

11/16

DEV26L

13/16

Additional terminal stud sizes available.


* BMY, BNCH-MT bench mount adapter available.
** NOTE: Add suffix "M" to cat. number to conform to
MS25036 - standard for these items only
(example: YAEV6C-L1M).
Contact Burndy for UL listed products.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES YAEV-RS
INSULUG
RIGHT-ANGLE TERMINALS
NYLON-INSULATED
Factory formed right angle INSULUG connectors made of seamless pure copper tubing. These rugged terminals withstand the
most severe applications. Inspection hole in
barrel permits visual check of wire insertion.
Meets requirements of MIL-T-7928.

CATALOG
NUMBER
YAEV8C-RS
YAEV8C-RS1
YAEV6C-RS1
YAEV6C-RS
YAEV4C-RS
YAEV4C-RS2
YAEV2C-RS1
YAEV2C-RS
YAEV1C-RS2
YAEV1C-RS
YAEV25-RS

YAEV26-RS

WIRE SIZE
8
Max. Insul. Dia.: .258
Sleeve Color: Red
6
Max. Insul. Dia.: .313
Sleeve Color: Blue
4
Max. Insul. Dia.: .374
Sleeve Color: Yellow
2
Max. Insul. Dia.: .459
Sleeve Color: Red
1
Max. Insul. Dia.: .516
Sleeve Color: White
1/0
Max. Insul. Dia.: .564
Sleeve Color: Blue
2/0
Max. Insul. Dia.: .628
Sleeve Color: Yellow

STUD
SIZE

8-10

.20

.41

.25

.82

1.25

1/4

.25

.41

.28

.84

1.25

8-10

.25

.50

.28

.88

1.28

1/4

.25

.50

.28

.88

1.20

1/4

.25

.53

.28

.95

1.28

3/8

.31

.62

.34

1.02

1.28

Z MIN. Y MAX. L MAX.

1/4

.33

.68

.34

1.13

1.62

3/8

.33

.68

.34

1.13

1.62

5/16

.33

.73

.34

1.22

1.65

1/4

.33

.73

.34

1.22

1.65

INSTALLATION TOOLING
HYPRESS Y29NC
HYTOOL
NEST
INDENTOR

LENGTH

DEV8L

7/16

DEV6L

DEV4L

1/2

DEV2L

5/8

DEV26L

5/8

Y29PLE-1

1/2

Y29PLE
3/8

.39

.81

.43

1.46

1.88

DEV25L

11/16

3/8

.39

.92

.47

1.48

2.06

DEV26L

13/16

Ratchet:
M8ND
with
N8CET-2 Die
Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U8CET Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U6CET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U4CET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U2CET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U1CET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U25ET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U26ET
Die Set

BMY BNCH-MT bench mount adapter available.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YAEV-H
INSULUG
RING-TONGUE TERMINALS
NYLON-INSULATED FOR
EXPANDED INSULATION
Designed to accommodate larger conductor
insulation diameters. Made of one piece tin
plated pure electrolytic seamless copper tubing for maximum conductivity and ductility.
Color-coded insulating sleeves are locked
into position. Inspection hole permits visual
check of wire insertion. Meets requirements
of MIL-T-7928

BULK
CATALOG
NUMBER
YAEV8C-H14
YAEV8C-H
YAEV8C-H1
YAEV8C-H2
YAEV8C-H3
YAEV8C-H4
YAEV6C-H1
YAEV6C-H
YAEV6C-H4
YAEV6C-H2
YAEV6C-H10
YAEV4C-H3
YAEV4C-H
YAEV4C-H4
YAEV4C-H2
YAEV4C-H5
YAEV2C-H3
YAEV2C-H1
YAEV2C-H2
YAEV2C-H
YAEV2C-H4
YAEV1C-H1
YAEV1C-H2
YAEV1C-H
YAEV1C-H3

WIRE
RANGE
8
Max. Insul.
Dia.: .30
Sleeve
Color: Red
6
Max. Insul.
Dia.: .38
Sleeve
Color: Blue
4
Max. Insul.
Dia.: .44
Sleeve
Color: Yellow
2
Max. Insul.
Dia.: .52
Sleeve
Color: Red
1
Max. Insul.
Dia.: .58
Sleeve Color: White

STUD
SIZE

6-8
8-10
1/4
5/16
3/8
1/2
8-10
1/4
5/16
3/8
1/2
8-10
1/4
5/16
3/8
1/2
8-10
1/4
5/16
3/8
1/2
1/4
5/16
3/8
1/2

.41
.41
.46
.57
.57
.73
.48
.48
.60
.60
.73
.55
.55
.62
.62
.73
.69
.69
.69
.69
.77
.76
.76
.76
.86

Z
MIN.

Y
MAX.

L
MAX.

INSTALLATION TOOLING
HYTOOL
Y29NC
HYPRESS
NEST
INDENTOR

.25
1.32
1.54
M8ND
.25
1.34
1.54
with
.28
1.37
1.61
N8CET-2 Die
.33
1.39
1.68
MY28-6*
.33
1.39
1.68
Y35, Y39 with
.47
1.52
1.91
U8CET Die
.28
1.48
1.73
MY28-6*
.28
1.48
1.73
Y35, Y39
.33
1.54
1.85
with U6CET
CONSULT
.34
1.54 FACTORY
1.85
Die Set
.47
1.68
2.06
FOR
AVAILABILITY
.28
1.60
1.87
MY28-6*
.28
1.60
1.87
Y35, Y39
.34
1.66
1.98
with
.34
1.66
1.98
U4CET
.47
1.79
2.18
.35
1.98
2.34
MY28-6*
.35
1.98
2.34
Y35, Y39
.35
1.98
2.34
with
.35
1.98
2.34
U2CET Die
.47
2.10
2.49
.38
2.10
2.49
MY28-6*
.38
2.10
2.49
Y35, Y39
.38
2.10
2.49
with
.47
2.10
2.62
U1CET Die

WIRE
STRIP
LENGTH

DEV8L

Y29PLE-1

7/16

DEV6L

Y29PLE-1

1/2

DEV4L

Y29PLE-1

1/2

DEV2L

Y29PLE

5/8

DV26L

Y29PLE

5/8

* BMY BNCH-MT bench mount adapter available.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YAEV-H
(Continued)
BULK
CATALOG
NUMBER

WIRE
RANGE

STUD
SIZE

YAEV25-H1
YAEV25-H2
YAEV25-H
YAEV25-H3
YAEV25-H4
YAEV26-H1
YAEV26-H2
YAEV26-H
YAEV26-H3
YAEV26-H12

1/0
Max. Insul.
Dia.: .66
Sleeve
Color: Blue
2/0
Max. Insul.
Dia.: .73
Sleeve Color:
Yellow

1/4
5/16
3/8
1/2
5/8
1/4
5/16
3/8
1/2
5/8

.83
.83
.83
.88
.88
.94
.94
.94
.94
.94

Z
MIN.

Y
MAX.

L
MAX.

INSTALLATION TOOLING
HYTOOL
Y29NC
HYPRESS
NEST
INDENTOR

.43
2.39
2.82
MY28-6*
.43
2.39
2.82
Y35, Y39
.43
2.39
2.82
with U25ET
CONSULT
.47
2.43 FACTORY
2.88
Die Set
.62
2.59
3.10
FOR
AVAILABILITY
.48
2.65
3.13
MY28-6*
.48
2.65
3.13
Y35, Y39
.48
2.65
3.13
with U26ET
.48
2.65
3.13
Die Set
.62
2.70
3.33

WIRE
STRIP
LENGTH

DEV25L

Y29PLE

11/16

DEV26L

Y29PLE

13/16

* BMY BNCH-MT bench mount adapter available.

10

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YAEV-RH
INSULUG
RIGHT-ANGLE TERMINALS,
NYLON-INSULATED
DESIGNED TO
ACCOMMODATE
LARGER CONDUCTOR
INSULATION DIAMETERS
Factory formed right angle INSULUG connectors made of seamless pure copper
tubing. These rugged terminals withstand the
most severe applications. Inspection hole in
barrel permits visual check of wire insertion.
Tin plated to resist corrosion. Meets requirements of MIL-T-7928.

CATALOG
NUMBER
YAEV8C-RH
YAEV8C-RH1
YAEV6C-RH1
YAEV6C-RH
YAEV4C-RH
YAEV4C-RH2
YAEV2C-RH1
YAEV2C-RH
YAEV1C-RH2
YAEV1C-RH
YAEV25-RH

YAEV26-RH

WIRE SIZE
8
Max. Insul. Dia.: .30
Sleeve Color: Red
6
Max. Insul. Dia.: .38
Sleeve Color: Blue
4
Max. Insul. Dia.: .44
Sleeve Color: Yellow
2
Max. Insul. Dia.: .52
Sleeve Color: White
1
Max. Insul. Dia.: .52
Sleeve Color: White
1/0
Max. Insul. Dia.: .66
Sleeve Color: Blue
2/0
Max. Insul. Dia.: .73
Sleeve Color: Yellow

STUD
SIZE

8-10

.20

.41

.25

.87

1.38

1/4

.25

.41

.28

.90

1.38

Z MIN. Y MAX. L MAX.

8-10

.25

.50

.28

.97

1.43

1/4

.25

.50

.28

.97

1.43

1/4

.25

.53

.28

1.04

1.53

3/8

.31

.62

.34

1.11

1.53

.33

.67

.34

1.22

1.88

1/4

5/16

CONSULT
FACTORY
.67
.34
1.22
1.88
FOR
AVAILABILITY
.33
.73
.34
1.32
1.99

1/4

.33

3/8

INSTALLATION TOOLING
HYPRESS Y29NC
HYTOOL
NEST
INDENTOR

.33

.73

.34

1.32

1.99

LENGTH

DEV8L

7/16

DEV6L

DEV4L

1/2

DEV2L

5/8

DV26L

5/18

Y29PLE-1

1/2

Y29PLE
3/8

.39

.81

.43

1.50

2.29

DEV25L

11/16

3/8

.39

.92

.47

1.60

2.42

DEV26L

13/16

Ratchet:
M8ND
with
N8CET-2 Die
Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U8CET Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U6CET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U4CET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U2CET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U1CET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U25ET
Die Set

Non-Ratchet:
MY28-6
Hydraulic:
Y35, Y39 with
U26ET
Die Set

BMY BNCH-MT bench mount adapter available.

For CUSTOMER SERVICE call 1-800-346-4175

11

BURNDY
Telecommunications Products
TYPES YAV BOX
AND YAV

BEVELED
ENTRY

SEAMLESS
BARREL
INSPECTION
HOLE

HEAVY DUTY RING TONGUE


HYLUG
CRIMP

#22-10 STRANDED AND


SOLID COPPER
HYLUG type YAV is a seamless, heavy
duty uninsulated compression ring tongue
terminal manufactured from pure electrolytic
copper tubing and is for use on copper commercial (code) cable, type AN aircraft cable
and extra flexible conductors. Because of its
seamless design, the YAV HYLUG also
accommodates solid conductors.
The seamless tubing produces a double thick
tongue and a strong connector for demanding
applications that require high reliability.
Applications include industrials, hospitals,
electric utilities, aircraft, shipboard and
marine, computers, steel mills, mining equipment and other equipment that is subject to
vibration or requiring dependable electrical
performance.
The YAV HYLUG terminals meet the
requirements of MIL-T-7928 (ASG).

CATALOG
NUMBER
YAV18-T4 BOX
YAV18-L33 BOX
YAV18-T5 BOX
YAV18-T1 BOX
YAV18 BOX
YAV14-L33 BOX
YAV14-T5 BOX
YAV14-T1 BOX
YAV14-L36 BOX
YAV14 BOX
YAV14-T2 BOX
YAV14-T3 BOX
YAV12-G2 BOX
YAV12-G3 BOX
YAV10-T7 BOX
YAV10-T11 BOX
YAV10-L36 BOX
YAV10 BOX
YAV10-T3 BOX
YAV10-T2 BOX
YAV10-T4 BOX
YAV9C-L36 BOX
YAV9C-T9 BOX
YAV9C-T4 BOX

WIRE
RANGE
22-18
Str.
and
Sol.
20-14
Str.
20-12
Sol.
14-12
Str.
14 Str.
12-10
Str.
and
Sol.
10-9
Str.

Available in (90o) right angle design.


Use #14 groove

12

ELECTRO-TIN
PLATED

DOUBLE THICK
TONGUE

Features and Benefits


Manufactured from seamless pure
electrolytic copper tubing.
Provides maximum conductivity,
low resistance and excellent ductility
for crimping.
Seamless tubular crimp barrel design.
No seams to split resulting in a very high
quality electrical connection. Also can be
used on solid conductor.
Double thick tongue.
Provides a very strong terminal tongue.
Produced from tubular copper.
Extra copper material assures the compression connector will operate cooler
than the conductors it connects.

STUD
SIZE

3, 4
4-6
4-6
6-8
8-10
4-6
4-6
6-8
8-10
8-10
1/4
5/16
8-10
1/4
4-6
6-8
8-10
8-10
1/4
5/16
3/8
8-10
1/4
5/16

.19
.25
.31
.31
.31
.25
.31
.31
.29
.31
.42
.44
.30
.36
.30
.38
.29
.38
.47
.53
.56
.31
.44
.52

DIMENSIONS
L MAX. Y MAX.
.62
.67
.76
.76
.76
.71
.79
.79
.74
.79
.99
.99
.82
1.00
.93
.97
.86
.97
1.10
1.13
1.18
.97
1.19
1.27

.54
.55
.61
.61
.61
.59
.64
.64
.59
.64
.75
.75
.67
.76
.78
.79
.71
.79
.87
.87
.90
.83
.95
1.02

Internally bevelled barrel.


Provides easy cable entry, especially
for flexible conductors.
Inspection hole.
Provides easy visual check for proper
conductor insertion.
Electro-tin plated.
Provides long lasting durable corrosion
resistance.
Nickel plating available, add NK suffix.
Nickel plated HYLUGS provide high
temperature applications up to 650F
continuous service and 750F intermittent service.

WIRE
STRIP
LENGTH

Z MIN.

BULK
CAT. NO.

INSTALLATION
TOOLING

.16
.18
.24
.24
.24
.18
.24
.24
.18
.24
.32
.32
.24
.34
.24
.26
.23
.26
.32
.31
.35
.15
.31
.36

YAV18-T4
YAV18-L33
YAV18-T5
YAV18-T1
YAV18
YAV14-L33
YAV14-T5
YAV14-T1
YAV14-L36
YAV14
YAV14-T2
YAV14-T3
YAV12-G2
YAV12-G3
YAV10-T7
YAV10-T11
YAV10-L36
YAV10
YAV10-T3
YAV10-T2
YAV10-T4
YAV9C-L36
YAV9C-T9

Non-Ratchet:
Y10D, Y10-22
Ratchet:
MR8G98, MR8-9Q,
Y8MRB-1, MR20

9/32

Non-Ratchet:
Y10D, Y10-22
Ratchet:
MR8G98, MR8-9Q,
Y8MRB-1, MR20

9/32

Y10D, Y8MRB-1
M8ND w/N14HT

9/32

Non-Ratchet:
Y10, Y10-22
Ratchet:
MR8G98, MR8-9Q,
Y8MRB-1, MR20

7/16

Ratchet:
MR8-9Q,
Y8MRB-1

7/16

UL listed for 14 Str. to #10 Sol. & Str. when installed with
MR8G98 and Y8MRB-1 tools only.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES YAV-L BOX
AND YAV-L HYLUG
SEAMLESS UNINSULATED
COMPRESSION TERMINAL,
RING TONGUE

CATALOG
NUMBER

WIRE
RANGE

YAV8C-L BOX
8
YAV8C-L1 BOX
Aircraft
YAV8C-L2 BOX
AN 8
YAV8C-L3 BOX
Flex
YAV8C-L4 BOX
YAV6C-L1 BOX
5&6
YAV6C-L BOX
Aircraft
YAV6C-L4 BOX
AN 5 & 6
YAV6C-L2 BOX
Flex
YAV6C-L10 BOX
YAV4C-L3 BOX
4
YAV4C-L BOX
Aircraft
YAV4C-L4 BOX
AN 4
YAV4C-L2 BOX
Flex
YAV4C-L5 BOX

2
YAV2C-L1 BOX
Aircraft
YAV2C-L2 BOX
AN 2
YAV2C-L BOX
Flex
YAV2C-L4 BOX

STUD
SIZE

MS20659
DASH NO.

6-8
8-10
1/4
5/16
3/8
1/2
8-10
1/4
5/16
3/8
1/2
8-10
1/4
5/16
3/8
1/2
8-10
1/4
5/16
3/8
1/2

-140
-107
-141
-108
-129
-142
-130
-109
-131
-110
-143
-144
-111
-132
-112
-145
-146
-113
-147
-114
-133

Class 1.
Available in (90) right angle design. Suffix "RS"
REPLACES SUFFIX "L".
Use Y35P3 INDENTOR ADAPTER with Y35 and Y39 Tool.

DIMENSIONS (INCH)
L
Y
Z
C MAX. MAX. MIN.
.41
.41
.46
.57
.57
.73
.48
.48
.60
.60
.73
.55
.55
.63
.63
.73
.69
.69
.69
.69
.77

1.15
1.15
1.22
1.30
1.30
1.52
1.31
1.31
1.43
1.43
1.64
1.37
1.37
1.48
1.48
1.68
1.72
1.72
1.72
1.72
1.89

.94
.94
.99
1.01
1.01
1.14
1.06
1.06
1.13
1.13
1.26
1.11
1.11
1.17
1.17
1.30
1.37
1.37
1.37
1.37
1.49

.28
.28
.32
.34
.34
.48
.29
.29
.35
.35
.49
.28
.28
.33
.33
.47
.35
.35
.35
.35
.46

BULK
CAT. NO.
YAV8C-L14
YAV8C-L
YAV8C-L1
YAV8C-L2
YAV8C-L3
YAV8C-L4
YAV6C-L1
YAV6C-L
YAV6C-L4
YAV6C-L2
YAV6C-L10
YAV4C-L3
YAV4C-L
YAV4C-L4
YAV4C-L2
YAV4C-L5
YAV2C-L3
YAV2C-L1
YAV2C-L2
YAV2C-L
YAV2C-L4

INSTALLATION TOOLING
HYPRESS
WIRE
DIE
Y29B,
Y35, Y39, STRIP
HYTOOL
INDEX Y29NC
Y750 LENGTH
Non-Ratchet:
MY29-11
Ratchet:
MR4C, MR8-9Q,
Y8MR8-1, M8ND
w/ N8CT Die Set
Non-Ratchet:
MY28,
MY29-11
Ratchet:
MR4C
Non-Ratchet:
MY28,
MY29-11
Ratchet:
MR4C
Non-Ratchet:
MY28,
MY29-11

38

39

40

41

DV8L-1
Nest
Y29PL
Indentor
(1) Crimp

UV8L
Nest
Y34PL
Indentor
(1) Crimp

DV6L
Nest
Y29PL
Indentor
(1) Crimp
DV4L
Nest
Y29PL
Indentor
(1) Crimp
DV2L
Nest
Y29PL
Indentor
(1) Crimp

UV6L
Nest
Y34PLA
Indentor
(1) Crimp
UV4L
Nest
Y34PLA
Indentor
(1) Crimp
UV2L
Nest
Y34PLA
Indentor
(1) Crimp

1/2

1/2

1/2

5/8

Bench Mount Adapter - Cat. BMY-BCH-MT is available for


Type "MY" HYTOOLS.
Add "NK" sufix for nickel plated Hylugs for high temperature applications up to 650 F continuous service and 750
intermittent service.

For CUSTOMER SERVICE call 1-800-346-4175

13

BURNDY
Telecommunications Products
TYPES YAV-L BOX
AND YAV-L HYLUG
SEAMLESS UNINSULATED
COMPRESSION TERMINAL,
RING TONGUE
(Continued)

CATALOG
NUMBER

YAV1C-L1 BOX
YAV1C-L2 BOX
YAV1C-L BOX
YAV1C-L3 BOX
YAV25-L1 BOX
YAV25-L2 BOX
YAV25-L BOX
YAV25-L3 BOX
YAV25-L4 BOX
YAV26-L1 BOX
YAV26-L2 BOX
YAV26-L BOX
YAV26-L3 BOX
YAV26-L12 BOX
YAV27-L BOX
YAV27-L1 BOX
YAV27-L15 BOX
YAV28-L BOX
YAV28-L12 BOX
YAV28-L13 BOX
YAV28-L14 BOX

WIRE
RANGE
1
Aircraft
AN 1
Flex
1/0
Aircraft
AN 1/0
Flex
2/0
Aircraft
AN 2/0
Flex
3/0 Aircraft
AN 3/0
Flex
4/0
Aircraft
AN 4/0
Flex

STUD
SIZE

MS20659
DASH NO.

8-10
1/4
5/16
3/8
1/2
1/4
5/16
3/8
1/2
5/8
1/4
5/16
3/8
1/2
5/8
3/8
1/2
5/8
3/8
1/2
5/8
3/4

-115
-149
-116
-134
-117
-151
-118
-135

-153
-119
-120
-136

-121
-122

-123
-124
-159
-160

Class 1.
Available in (90) right angle design. Suffix "RS" replaces
suffix "L".
Use Y35P3 INDENTOR ADAPTER with Y35 and Y39 Tool.

14

DIMENSIONS (INCH)
L
Y
Z
C MAX. MAX. MIN.
.76
.76
.76
.76
.86
.83
.83
.83
.88
.88
.93
.93
.93
.93
.93
1.03
1.03
1.03
1.12
1.12
1.12
1.23

1.67
1.84
1.84
1.84
1.97
2.01
2.01
2.01
2.09
2.31
2.32
2.32
2.32
2.32
2.52
2.45
2.45
2.60
2.72
2.72
2.72
2.95

1.32
1.45
1.45
1.45
1.54
1.61
1.61
1.61
1.64
1.80
1.85
1.85
1.85
1.85
1.99
1.93
1.93
2.04
2.16
2.16
2.16
2.33

.25
.38
.38
.38
.46
.43
.43
.43
.46
.62
.48
.48
.48
.48
.62
.52
.52
.62
.60
.60
.60
.78

BULK
CAT. NO.
YAV1C-L6
YAV1C-L1
YAV1C-L2
YAV1C-L
YAV1C-L3
YAV25-L1
YAV25-L2
YAV25-L
YAV25-L3
YAV25-L4
YAV26-L1
YAV26-L2
YAV26-L
YAV26-L3
YAV26-L12
YAV27-L
YAV27-L1
YAV27-L15
YAV28-L
YAV28-L12
YAV28-L13
YAV28-L14

HYTOOL

INSTALLATION TOOLING
HYPRESS
DIE
Y29B,
Y35, Y39,
INDEX Y29NC
Y750

42

43
Non-Ratchet:
MY28,
MY29-11

44

DV1L
Nest
Y29PL
Indentor
(1) Crimp
DV25L
Nest
Y29PR
Indentor
(1) Crimp
DV26L
Nest
Y29PL
Indentor
(1) Crimp

45

46

UV1L
Nest
Y34PLA
Indentor
(1) Crimp
UV25L
Nest
Y34PA
Indentor
(1) Crimp
UV26L
Nest
Y34PA
Indentor
(1) Crimp
UV27L Nest
Y34PA Indentor
(1) Crimp
UV28L Nest
Y34PA
Indentor
(1) Crimp

WIRE
STRIP
LENGTH

5/8

11/16

13/16

13/16

7/8

Bench Mount Adapter - Cat. BMY-BCH-MT is available for


Type "MY" HYTOOLS.
Add "NK" sufix for nickel plated HYLUGS for high
temperature applications up to 650 F continuous service
and 750 intermittent service.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES YAV-R, YAV-RS
HEAVY DUTY RIGHT-ANGLE
HYLUG
Factory formed right angle HYLUG connectors made of seamless pure copper tubing. These rugged terminals withstand the
most severe applications. Inspection hole in
barrel permits visual check of wire insertion.
Tin plated to resist corrosion. Meets requirements of MIL-T-7928

CATALOG
NUMBER
YAV18-R
YAV14-RL33
YAV14-R
YAV10-R
YAV10-R3 BOX

BULK
CATALOG
NUMBER
YAV8C-RS
YAV8C-RS1
YAV8C-RS3
YAV6C-RS1
YAV6C-RS
YAV6C-RS4
YAV6C-RS2
YAV4C-RS3
YAV4C-RS
YAV4C-RS4
YAV4C-RS2
YAV2C-RS1
YAV2C-RS2
YAV2C-RS
YAV1C-RS1
YAV1C-RS2
YAV25-RS
YAV25-RS3
YAV26-RS
YAV26-RS3
YAV27-RS
YAV28-RS

WIRE
RANGE

STUD
SIZE

22-18

8-10
4-6
8-10
8-10
1/4

.31
.25
.31
.38
.47

20-14
12-10

WIRE
8

2
1
1/0
2/0
3/0
4/0

STUD

8-10
1/4
3/8
8-10
1/4
5/16
3/8
8-10
1/4
5/16
3/8
1/4
5/16
3/8
1/4
5/16
3/8
1/2
3/8
1/2
3/8
3/8

.41
.41
.56
.50
.50
.59
.59
.53
.53
.62
.62
1.27
.68
.68
.73
.73
.82
.88
.92
.92
1.02
1.13

DIMENSIONS
L MAX.
Y MAX.
Z MIN.
.35
.37
.38
.55
.57

.54
.45
.57
.58
.60

DIMENSIONS IN INCHES
L MAX.
Y MAX.
Z MIN.
1.00
1.00
1.00
1.02
1.02
1.02
1.02
1.04
1.04
1.04
1.04
1.05
1.27
1.27
1.35
1.35
1.51
1.51
1.63
1.63
1.65
1.80

.75
.79
.85
.81
.81
.89
.89
.87
.87
.95
.95
.34
1.05
1.05
1.15
1.15
1.29
1.32
1.40
1.40
1.54
1.54

.25
.28
.34
.28
.28
.34
.34
.28
.28
.34
.34
.33
.34
.34
.34
.34
.43
.47
.47
.47
.47
.47

.25
.21
.25
.25
.28

N
.20
.20
.20
.25
.25
.31
.31
.25
.25
.31
.31
.33
.33
.33
.33
.33
.39
.44
.39
.39
.48
.48

INSTALLATION
TOOLING

.16
.12
.16
.19
.23

Non-Ratchet:
Y10D
Ratchet:
Y8MRB-1, MR20,
MR8-G98, MR8-9Q

WIRE
STRIP
LENGTH
1/4
5/16

INSTALLATION TOOLING
HYPRESS Y29NC
HYTOOL
NEST
INDENTOR

WIRE
STRIP
LENGTH

DV8L-1*

7/16

DV6L
1/2
MY28
MY29-11

Y29PL
DV4L

DV2L

5/8

DV1L

5/8

DV25L

11/16
Y29PR

DV26L

13/16

7/8

* For aircraft applications (Flexible Cable) use die


DV8L-1

For CUSTOMER SERVICE call 1-800-346-4175

15

BURNDY
Telecommunications Products
TYPES TP-F
AND BA-EF

EXPANDED SHROUD
INSULATION CRIMP

WIRE
CRIMP
WIRE SIZE
RANGE

SMOOTH
ENTRY

VINYLUG
TERMINAL
POLYVINYLCHLORIDE
INSULATED, FORK TONGUE

FORK
TONGUE

COLOR CODED
INSULATION
DEEP V
SERRATIONS

TIN
PLATED

600 VOLT MAX. 105C MAX


The Type TP-F is a fork tongue variation of
the TP design and makes installation easier.

Features and Benefits


Fork tongue.
Faster installation screw needs only to
be loosened for termination.

CATALOG
NUMBER
TP16-2F
TP16-6F
TP16-8F
TP16-10F
TP14-2F
TP14-6F
TP14-8F
TP14-10F
TP10-6F
TP10-8F
TP10-10F

WIRE
RANGE

STUD
SIZE

22-16
Max. Insul.
Dia. Accom.: .145
Color Code: Red
16-14
Max. Insul.
Dia. Accom.: .180
Color Code: Blue
12-10
Max. Insul.
Color Code: Yellow

1-2
4-6
6-8
8-10
1-2
4-6
6-8
8-10
4-5
6-8
8-10

.17
.28
.31
.41
.17
.28
.31
.41
.28
.31
.41

DIMENSIONS
BULK
L
Y
Z
CATALOG
MAX. MAX. MIN. NUMBER
.75
.80
.86
.95
.75
.80
.86
.95
.95
.98
1.07

.66
.66
.69
.75
.66
.66
.69
.75
.81
.81
.87

.23
.23
.26
.31
.23
.23
.26
.31
.26
.26
.31

BA16EF2
BA16EF6
BA16EF8
BA16EF10
BA14EF2
BA14EF6
BA14EF8
BA14EF10
BA10EF6
BA10EF8
BA10EF10

INSTALLATION
TOOLING

Plier Type:
Y10-22

Ratchet Tool:
MR8-89-1,
MR15

TAPE MOUNTED
WIRE
CATALOG NO. INSTALLATION STRIP
2000/Reel
TOOLING
LENGTH
BA16EF2M
BA16EF6M
BA16EF8M
BA16EF10M
BA14EF2M
BA14EF6M
BA14EF8M
BA14EF10M
*BA10EF6M
*BA10EF8M
*BA10EF10M

TFM
with
DFM3D-1
Die
TFM
with
DFM2D-1
Die
TFM
with
DFM1D5 Die

13/64

13/64

19/64

UL and CSA listed with MR8-89-1 and MR15.


* 1000/Reel.

16

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES TP-Z
AND BA-EZ

EXPANDED SHROUD
INSULATION
CRIMP
WIRE
CRIMP

VINYLUG

WIRE SIZE
RANGE

TERMINAL
POLYVINYLCHLORIDE
INSULATED,
FLANGED FORK TONGUE

DEEP V
SERRATIONS
FLANGED
FORK

VINYLUG Type TP-Z is a variation of the


Type TP and employs a flanged fork tongue
for fast installation and security.

TP16-2Z
TP16-6Z
TP16-8Z
TP16-10Z
TP14-2Z
TP14-6Z
TP14-8Z
TP14-10Z
TP10-6Z
TP10-8Z
TP10-10Z

TIN PLATED

Features and Benefits

600 VOLT MAX. 105C MAX

CATALOG
NUMBER

FUNNEL
ENTRY

WIRE
RANGE

STUD
SIZE

22-16
Max. Insul.
Dia. Accom.: .145
Color Code: Red
16-14
Max. Insul.
Dia. Accom.: .180
Color Code: Blue
12-10 Max. Insul.
Dia. Accom.: .260
Color Code: Yellow

1-2
4-6
6-8
8-10
1-2
4-6
6-8
8-10
4-6
6-8
8-10

.17
.28
.31
.41
.17
.28
.31
.41
.28
.31
.41

Flanged fork tongue design.


Allows fast installationscrew only has
to be loosened for termination.
The flanges on the end of the fork terminal
aid in preventing a slightly loose terminal
from becoming fully disconnected from
the screw.
Flanges make re-securing a loose
terminal easier.

DIMENSIONS
BULK
L
Y
Z
CATALOG
MAX. MAX. MIN. NUMBER
.78
.83
.88
.96
.78
.83
.88
.96
.99
1.01
1.09

.66
.66
.69
.75
.66
.66
.69
.75
.81
.81
.81

.23
.23
.26
.31
.23
.23
.26
.31
.26
.26
.31

BA16EZ2
BA16EZ6
BA16EZ8
BA16EZ10
BA14EZ2
BA14EZ6
BA14EZ8
BA14EZ10
BA10EZ6
BA10EZ8
BA10EZ10

INSTALLATION
TOOLING

Plier Type:
Y10-22

Ratchet Tool:
MR8-89-1,
MR15

TAPE MOUNTED
WIRE
CATALOG NO. INSTALLATION STRIP
2000/Reel
TOOLING
LENGTH
BA16EZ2M
BA16EZ6M
BA16EZ8M
BA16EZ10M
BA14EZ2M
BA14EZ6M
BA14EZ8M
BA14EZ10M
*BA10EZ6M
*BA10EZ8M
*BA10EZ10M

TFM
with
DFM3D-1
Die
TFM
with
DFM2D-1
Die
TFM
with
DFM1D5 Die

13/64

13/64

19/64

* 1000/Reel.

For CUSTOMER SERVICE call 1-800-346-4175

17

BURNDY
Telecommunications Products
TYPES TP-LF AND
BA-EL

WIRE SIZE
RANGE

VINYLUG

LOCKING
FORK
COLOR CODED
INSULATION

TERMINAL
POLYVINYLCHLORIDE
INSULATED,
LOCKING FORK TONGUE

Features and Benefits

Type TP-LF is a variation of the Type TP


design and employs a locking fork tongue for
fast installation and security.

TP16-6LF
TP16-8LF
TP16-10LF
TP14-6LF
TP14-8LF
TP14-10LF
TP10-6LF
TP10-8LF
TP10-10LF

DEEP V
SERRATIONS

TIN PLATED

600 VOLT MAX. 105C MAX

CATALOG
NUMBER

EXPANDED SHROUD
INSULATION CRIMP

WIRE
CRIMP

Locking fork tongue design.


Allows fast installationscrew only has
to be loosened for termination.
Internal configuration of the fork.
Prevents the terminal from coming
off the screw without applying a
pulling force.
Locking fork is made from a copper alloy.
Permits many installations while maintaining proper spring retention of forks.

DIMENSIONS
L MAX. Y MAX. Z MIN.

BULK
CATALOG
NUMBER

WIRE
RANGE

STUD
SIZE

22-16
MAX. INSUL.
DIA. ACCOM.: .145
COLOR CODE: Red
16-14
MAX. INSUL.
DIA. ACCOM.: .180
COLOR CODE: Blue
12-10
MAX. INSUL.
DIA. ACCOM.: .260
COLOR CODE: Yellow

4-6

.28

.80

.66

.23

BA16EL6

6-8

.31

.86

.69

.26

BA16EL8

INSTALLATION
TOOLING

TAPE MOUNTED
WIRE
CATALOG NO. INSTALLATION STRIP
2000/Reel
TOOLING
LENGTH
BA16EL6M

PLIER TYPE:
Y10-22

BA16EL8M

8-10

.41

.95

.75

.31

BA16EL10

4-6

.28

.80

.66

.23

BA14EL6

BA14EL6M

6-8

.31

.86

.69

.26

BA14EL8

BA14EL8M

8-10

.41

.95

.75

.31

BA14EL10

4-6

.28

.95

.81

.26

BA10EL6

6-8

.31

.98

.81

.26

BA10EL8

8-10

.41

1.07

.87

.31

BA10EL10

RATCHET
TOOL:
MR8-89-1
MR15

BA16EL10M

BA14EL10M

TFM
WITH
DFM3D-1
DIE
TFM
WITH
DFM2D-1
DIE

* BA10EL6M

TFM

* BA10EL8M

WITH

* BA10EL10M

DFM1D5 DIE

13/64

13/64

19/64

UL and CSA listed with MR8-89-1 and MR15.


* 1000/Reel.

18

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES TN-F, YAE-F
AND YAES-F

WIRE CRIMP

INSULATION
CRIMP

BRAZED
SEAM

SMOOTH
FUNNEL
ENTRY

INSULUG
TERMINAL
NYLON INSULATED,
FORK TONGUE
300 VOLT MAX. 105C MAX
The type TN-F, nylon insulated fork tongue
terminal has the same high quality as the TN.
It is designed to meet the heavy-duty requirements of industrial and utility applications.

FORK
TONGUE
DEEP V
SERRATIONS

TIN
PLATED

Features and Benefits


Fork tongue.
Provides faster and easier installation
by permitting insertion under the screw
head without completely removing it.

Used on both power and control circuits for


wire sizes #26 AWG through #10 AWG. The
TN-F provides high dielectric strength and
stability in oily conditions.
The TN-F is identical to the TN with the addition of a fork tongue which allows installation
without complete removal of its supporting
screw.

CATALOG
NUMBER
TN20-2F*
TN20-6F*
TN18-6F
TN18-8F
TN18-10F
TN18-14F
TN14-6F
TN14-8F
TN14-10F
TN14-14F
TN10-6F
TN10-8F
TN10-10F
TN10-14F

WIRE
RANGE

STUD
SIZES

DIMENSIONS
L MAX. Y MAX.

26-20 Max. Insul.


Dia. Accom.: .098
Color Code: Amber
22-18
Max. Insul.
Dia. Accom.: .120
Color Code: Red
16-14
Max. Insul.
Dia. Accom.: .153
Color Code: Blue
12-10
Max. Insul.
Dia. Accom.: .209
Color Code: Yellow

1-2

.18

.76

.65

.24

4-6

.28

.80

.70

.28

4-6
6-8
8-10
1/4
4-6
6-8
8-10
1/4
4-6
6-8
8-10
1/4

.28
.31
.37
.47
.28
.31
.37
.47
.28
.31
.41
.50

.79
.84
.84
1.03
.79
.84
.84
1.03
.96
1.01
1.09
1.21

.65
.67
.68
.79
.65
.67
.68
.79
.82
.84
.89
.96

.24
.26
.27
.38
.24
.26
.27
.38
.24
.26
.31
.38

YAES18N1F
YAES18N49F
YAES18N3F
YAES18N50F
YAES14N6F
YAES14N53F
YAES14N8F
YAES14N54F
YAES10N11F
YAES10N56F
YAES10N12F
YAES10N57F

Z MIN.

BULK
CAT. NO.

INSTALLATION
TOOLING
M8ND with
N14HET-25V1
Die Set

Non-Ratchet:
Y10D, Y10-22

WIRE
STRIP
LENGTH
3/16

7/32

7/32
Ratchet:
MR8-83**, MR18

11/32

* These sizes not UL listed.


** Or other tool conforming to military specification MS25037
or MS90413

For CUSTOMER SERVICE call 1-800-346-4175

19

BURNDY
Telecommunications Products
TYPES YAE-N-F BOX
AND YAE-N-F

MULTI-FINGER
INSULATION GRIPS
AND CABLE SUPPORT

FUNNEL
ENTRY

WIRE SIZE

INSULUG
TERMINAL
NYLON INSULATED,
FORK TONGUE

INSULUG type YAE-N-F nylon insulated


terminals are designed with a Multi-Finger
Insulation grip, are rated 105C and are supplied with a fork tongue for easy terminal
insertion and removal.

24 - 20 Max. Insul.
Dia.: .098
Sleeve Color:
YAE22N66F BOX
Amber
YAE22N65F BOX

YAE18N60F BOX
YAE18G43F BOX
YAE18N56F BOX

22 - 16
Max. Insul.
Dia.: .125
Sleeve Color: Red

YAE18N57F BOX
YAE14N76F BOX
YAE14N77F BOX
YAE14N78F BOX

16 - 14
Max. Insul.
Dia.: .156
Sleeve Color: Blue

WIRE
CRIMP

Features and Benefits

300 VOLT MAX. 105C MAX

WIRE
RANGE

DEEP V
SERRATIONS

FORK
TONGUE

MULTI-FINGER
INSULATION GRIP

CATALOG
NUMBER

INSULATION
CRIMP

ELECTRO-TIN
PLATED

STUD
SIZE

Fork tongue.
Permits rapid easy installation of the
terminal under the screw head without
complete removal of the screw.

DIMENSIONS
BULK
L
Y
Z CATALOG
C MAX. MAX. MIN. NUMBER

1-2

.18

.73

.65

.24

YAE22N65F

4-6

.28

.80

.70

.28

YAE22N66F

.21

.92

.73

.24

YAE18N60F

.25

.78

.68

.19

YAE18G43F

.28

.83

.76

.23

YAE18N56F

6-8

.31

.96

.78

.29

YAE18N57F

4-6

.28

.87

.76

.26

YAE14N76F

6-8

.31

.96

.78

.29

YAE14N77F

8 - 10

.36

1.01

.83

.34

YAE14N78F

4-6

INSTALLATION
TOOLING
Ratchet:
M8ND
N14HET25V1
Die
Non-Ratchet: Y10D or
Ratchet: MR8-33T-1,
M8ND
With one of the
following Dies:
N14HET-25V1,
N10ET-9,
N14HET-15
Non-Ratchet:
Y10D or Y10-22 or
Ratchet:
MR8-33T1

TAPE MOUNTED
WIRE
CATALOG NO. INSTALLATION STRIP
2000/Reel
TOOLING
LENGTH
YAE22N65FM
YAE22N66FM

TFM
with
DFM11D1
Die

5/32

TFM
with
DFM10D1
Die

3/16

TFM
with
DFM9D1
Die

3/16

YAE18G60FM
YAE18G43FM
YAE18N56FM
YAE18N57FM
YAE14N76FM
YAE14N77FM
YAE14N78FM

Not UL recognized.

20

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES YAE-Z BOX
AND YAE-Z

MULTI-FINGER
INSULATION GRIPS
AND CABLE SUPPORT
WIRE SIZE

INSULUG
TERMINAL
NYLON INSULATED, FLANGED
FORK
MULTI-FINGER
INSULATION GRIP

INSULUG type YAE-Z is identical to type


YAE-N and employs a flanged fork tongue for
faster installation while maintaining security if
supporting screw becomes loose.

CATALOG
NUMBER

WIRE
RANGE

STUD
SIZE

YAE22Z1 BOX
YAE22Z2 BOX
YAE22Z3 BOX
YAE18Z1 BOX
YAE18Z2 BOX
YAE18Z3 BOX
YAE18Z4 BOX
YAE14Z2 BOX
YAE14Z3 BOX
YAE14Z4 BOX
YAE12Z2 BOX
YAE12Z3 BOX
YAE12Z4 BOX

26-20 Max. Insul.


Dia.: .098
Sleeve Color: Amber

1-2
4-6
6-8
1-2
4-6
6-8
8-10
4-6
6-8
8-10
4-6
6-8
8-10

.18
.28
.31
.18
.28
.31
.36
.28
.31
.36
.28
.31
.36

16-14 Max. Insul.


Dia. Accom.: (156)
Color Code: Blue
14-12 Max. Insul.
Dia. Accom.: (180)
Color Code: Green

ELECTRO-TIN
PLATED

INSULATION
CRIMP
WIRE CRIMP
DEEP V
SERRATIONS

FLANGED
FORK

Features and Benefits

300 VOLT MAX. 105C MAX

22-16 Max. Insul.


Dia. Accom.: (125)
Color Code: Red

FUNNEL
ENTRY

Flanged fork.
Permits rapid, easy installation of the
terminal under the screw head without
complete removal of the screw.
Additionally, it may not be removed with
only a slight loosening of the screw.

DIMENSIONS
BULK
Z
Y
L
CATALOG
MAX. MAX. MAX. NUMBER
.24
.28
.30
.22
.26
.29
.34
.26
.29
.34
.27
.32
.35

For CUSTOMER SERVICE call 1-800-346-4175

.65
.70
.72
.73
.76
.78
.83
.76
.78
.83
.90
.96
1.00

.75
.83
.92
.83
1.00
1.00
1.08
.90
1.00
1.08
1.04
1.16
1.23

YAE22Z1
YAE22Z2
YAE22Z3
YAE18Z1
YAE18Z2
YAE18Z3
YAE18Z4
YAE14Z2
YAE14Z3
YAE14Z4
YAE12Z2
YAE12Z3
YAE12Z4

INSTALLATION
TOOLING
M8ND with
N14HET-25V1 Die
Y10D, Y10-22
MR8-33T-1,
M8ND
with one of the
following Dies:
N14HET-15, N10HET-9,
Y10D, Y10-22
MR833T-1, M8ND
with N12HET-1,
Y10D, Y10-22

TAPE MOUNTED
WIRE
CATALOG NO. INSTALLATION STRIP
2000/Reel
TOOLING
LENGTH
YAE22Z1M
YAE22Z2M
YAE22Z3M
YAE18Z1M
YAE18Z2M
YAE18Z3M
YAE18Z4M
YAE14Z2M
YAE14Z3M
YAE14Z4M
YAE12Z2M
YAE12Z3M
YAE12Z4M

TFM with
DFM11D1
Die
TFM
with
DFM10D1
Die
TFM
with
DFM9D1 Die
TFM
with
DFM7D1 Die

5/32

3/16

13/16

21/64

21

BURNDY
Telecommunications Products
TYPES YAV-H-F BOX,
YAV-H-F AND YAV-Z

Type YAV-H-F

INSULATION
GRIP AND
CABLE SUPPORT

SEAMLESS
BARREL

INSPECTION
HOLE

FORK TONGUE HYLUG


UNINSULATED

ELECTRO-TIN
PLATED

CRIMP
CRIMP

The type "YAV-H-F" HYLUG is a seamless


heavy duty uninsulated compression fork
tongue terminal with a shroud for an insulation grip and cable support. Manufactured
from electrolytic copper tubing for use on copper commercial (code) cable, Type "AN" aircraft and extra flexible conductors.

WIRE RANGE
FORK TONGUE
DOUBLE THICK
TONGUE

SEAMLESS
BARREL

Type YAV-Z

INSULATION
GRIP AND
CABLE SUPPORT

INSPECTION
HOLE

The seamless tubing produces a double thick


tongue while the seamless barrel design provides a very strong connector for very
demanding applications that require highly
reliable connections.

ELECTRO-TIN
PLATED

CRIMP
CRIMP
WIRE RANGE

In addition to the benefits described for the


YAV box series of connectors the YAV-H- Box
and YAV-Z terminals provide the following
benefits.

FLANGED
FORK TONGUE

DOUBLE THICK
TONGUE

Features and Benefits


Fork tongue.
Allows installation of compression terminal under screw head without complete
removal of the screw thereby lowering
installation costs.
Flanged fork tongue.
Allows installation of compression terminal under screw head without complete
removal of the screw plus aids in maintaining the terminal on the stud should
the screw loosen slightly.

Fig. 1

Fig. 2

CATALOG
NUMBER

FIG.

YAV18-H6F BOX
YAV18-H19 BOX
YAV18-H21F BOX
YAV14-Z5 BOX
YAV14-H32F BOX
YAV14-H56F BOX
YAV14-H34F BOX
YAV14-HF BOX
YAV14-Z6 BOX
YAV10-HF BOX

1
1
1
2
1
1
1
1
2
1

WIRE
RANGE
22-18

20-14

12-10

STUD
SIZE

MAX. INSUL.
DIA. ACCOM.

4-6
4-6
8-10
4-6
4-6
6-8
8-10
8-10
8-10
8-10

.120
.120
.120
.150
.150
.150
.150
.150
.150
.192

.25
.30
.37
.31
.30
.30
.37
.31
.37
.38

DIMENSIONS
L MAX. Y MAX. Z MIN.
.89
.97
.97
.89
.96
.96
.96
.93
1.04
1.07

.80
.75
.76
.69
.78
.78
.78
.78
.78
.92

.19
.21
.22
.13
.23
.23
.23
.23
.21
.24

BULK
CAT. NO.

INSTALLATION
TOOLING

YAV18-H6F
YAV18-H19F
YAV18-H21F
YAV14-Z5
YAV14-H32F
YAV14-H56F
YAV14-H34F
YAV14-HF
YAV14-Z6
YAV10-HF

Plier:
Y10D*, Y14MV,
Y10-22*
Ratchet:
MR8-G98,
MR8-9Q,
Y8MRB-1*,
MR20, and M8ND
with N14HT-5 Die
N10HT Die

WIRE
STRIP
LENGTH

1/4

7/16

* Crimps conductor crimp only.

22

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES SP AND BS

INSULATION
SUPPORT
CRIMP

VINYLINK BUTT SPLICE


PVC INSULATED

CRIMP

600 VOLTS, 105C


VINYL
INSULATION

The type SP VINYLINK is a PVC insulated


seamless butt splice. Type SP VINYLINK is
designed to accommodate a broad range of
600 volt cables.

SMOOTH
ENTRY

Features and Benefits


Manufactured from seamless electrolytic
copper tubing.
Provides maximum conductivity and
tensil strength, in a high quality with
NO seams to split.
Funnel entry.
Provides easy wire insertion.
Electro-tin plated.
Provides durable long lasting
resistance to corrosion.

CATALOG
NUMBER

WIRE
RANGE

COLOR
CODE

BULK
CAT. NO.

SP16
SP14
SP10

22-16
16-14
12-10

Red
Blue
Yellow

BS16
BS14
BS10

For CUSTOMER SERVICE call 1-800-346-4175

Expanded insulation support.


Red wire range of 22-16.
Lower inventory requirements.
Vinyl insulator.
Economical means of providing
high dielectric values and cable
insulation support.

DIMENSION (INCHES)
L MAX.
MAX.
INSUL.
DIA.
1.00
1.00
1.23

.145
.180
.260

INSTALLATION
TOOLING
Non-Ratchet: Y10D-22, Y10D
Ratchet: MR8-9-1, MR15

WIRE
STRIP
LENGTH
1/4
1/4
21/64

23

BURNDY
Telecommunications Products
TYPES SN
AND YSE-HN

TRANSPARENT WINDOWS
FOR EASY INSPECTION

NYLON
INSULATION

INSULINK BUTT SPLICE,


NYLON-INSULATED
INTEGRAL METAL
CABLE SUPPORT
AND STRAIN RELIEF

600 VOLTS MAXIMUM,


105 MAXIMUM
The type SN INSULINK is a high quality
nylon-insulated butt splice designed to meet
heavy duty application requirements.
Meets the functional requirements of MIL-T7928 (ASG) and conforms to the requirements of NAS1388.

SEAMLESS ELECTRO-TIN
PLATED SPLICE

Features and Benefits


Manufactured from one-piece tin-plated
seamless copper tubing with an integral
barrel/insulation grip.
Provides maximum tensile strength, plus
excellent cable support and strain relief
and eliminates failures due to vibration.
Smooth funnel entry.
Provides easy wire insertion.
Window and transparent color-coded nylon
insulation.
Provides easy visual inspection for proper
wire insertion.

Window position locator for full cycle ratchet tool crimp.


Provides proper tool/connector alignment
for correct crimp.
Nylon insulation offers high dielectric
strength and stability in oily environmental
conditions.
Maintains a high quality connection in
demanding applications.
The nylon is locked into position.
The connector will not move.

600 VOLTS, 105 C


(1000 VOLTS, MAX. INSIDE SIGN OR FIXTURE)

24

CATALOG
NUMBER

WIRE
RANGE

COLOR
CODE

BULK
CAT. NO.

SN18
SN14
SN10

22-18
16-14
12-10

Red
Blue
Yellow

YSE18HN
YSE14HN
YSE10HN

DIMENSIONS
L MAX.
MAX.
INSUL.
DIA.
1.25
1.25
1.64

.115
.150
.220

INSTALLATION
TOOLING
Plier: Y10D
Ratchet: MR8-85, MR18

WIRE
STRIP
LENGTH
15/64
7/32
3/8

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES SNM
AND YSES

NYLON
INSULATION

LOCATOR RING
INSPECTION
WINDOW

INSULINK BUTT SPLICE,


NYLON INSULATED

INTEGRAL METAL
INSULATION GRIP
AND STRAIN RELIEF

MS25181, CLASS 1 SPLICE


300 VOLT 105C

Features and Benefits

The type SNM INSULINK is a high quality


nylon insulated butt splice designed to meet
military MS25181, class 1 requirements.

CATALOG
NUMBER

Manufactured from tin plated, seamless


copper tubing with an integral
barrel/insulation grip.
Provides maximum tensil strength, plus
excellent cable support and strain relief.
Smooth funnel entry.
Provides easy wire insertion.

DIMENSIONS
L
MAX.
MAX.
DIA. INSUL.

WIRE
RANGE

COLOR
CODE

BULK
CAT. NO.

MS25181
DASH NO.

SNM18

22-18

Red

YSES18-1

-1

1.53

.120

SNM14

16-14

Blue

YSES14-2

-2

1.53

.150

TYPES YSE BOX,


YSE-H BOX, YSE
AND YSE-H

Plier: Y10D
Ratchet: MR8-83 or
MR8-85 MS25037 TOOL

WIRE
STRIP
LENGTH
7/32
7/32

FUNNEL
ENTRY

SPLIT HEAVY
WALL INSULATION
GRIP

SEAMLESS

NYLON
INSULATION

Fig. 1

Features and Benefits

600 VOLT, 105C


The types YSE and YSE-H INSULINKS are
high quality nylon insulated butt splices
designed for splicing aircraft and commercial
flexible cables.

600 VOLTS 105C

YSE18H-BOX
YSE14H-BOX
YSE10-BOX

INSTALLATION
TOOLING

INSPECTION
WINDOW

INSULINK BUTT SPLICE,


NYLON-INSULATED

WIRE RANGE
CATALOG
NUMBER

Transparent nylon insulation.


Permits easy wire inspection.
External ring locator.
Provides proper tool alignment for
correct crimp.

Manufactured from tin plated, seamless


electrolytic copper tubing with integral barrel/insulation grip.
Provides maximum conductivity and tensile strength, plus excellent cable support
and strain relief.
Split heavy wall insulation grip.
Provides stronger insulation grip and
strain relief.
Smooth funnel entry.
Provides easy wire insertion.
Transparent nylon insulation.
Permits easy wire inspection.

FIG.

WIRE
CODE AWG.
AIRCRAFT AN

COLOR
CODE

BULK
CAT. NO.

1
1
2

22-18
16-14
12-10

Red
Blue
Yellow

YSE18H
YSE14H
YSE10

For CUSTOMER SERVICE call 1-800-346-4175

Fig. 2

DIMENSIONS
L MAX.
MAX.
INSUL.
DIA.
1.220
1.36
1.15

.115
.150
.209

INSTALLATION
TOOLING

WIRE
STRIP
LENGTH

Y10D
Ratchet:
MR8-33S-1

9/32
11/32
23/64

25

BURNDY
Telecommunications Products
TYPES YSV, YRV-L
HYREDUCER BUTT SPLICE
The HYREDUCER is a connector for splicing two different size wires. The larger conductor is inserted first and butts against the
center of the connector where the smaller
barrel begins. Constructed of pure electrolytic
copper tubing for maximum conductivity, tin
plated to resist corrosion, the HYREDUCER accommodates a wide range of cable
sizes.

Fig. 2

Fig. 1

Fig. 3

Dimensional information may be found in


Table 1. Table 2 is a comprehensive tooling
index for these connectors.

TABLE 1
BULK
CATALOG
NUMBER

TOTAL
WIRE
RANGE

FIG.
NO.

YSV1418

22 - 14

20 - 14

.27

22 - 18

YSV1214-G1

16 - 12

12

.31

B BARREL*
WIRE SIZE
B DIM.

TOOL
INDEX

BB BARREL*
WIRE SIZE
BB DIM.

TOOL
INDEX

L
MAX.

.27

.64

16 - 14

.27

.83

YSV1014-G2

20 - 10

12 - 10

.31

20 - 14

.27

.83

YRV8CV14-L

20 - 8

.44

20 - 14

.39

YRV8CV10-L

12 - 8

.44

12 - 10

.53

1.18

YRV6CV10-L

12 - 6

.50

12 - 10

.53

1.28

YRV6CV8C-L

8-6

.50

.53

1.21

YRV4CV6C-L

6-4

.50

.54

1.27

YRV2CV6C-L

6-2

.62

.51

1.63

* B and BB dimensions are wire strip lengths.

TABLE 2
INDEX
NUMBER

1
2
4
5
6
7
8

TOOL INDEX
HAND
TOOLS
MR8G98
Y8MRB-1
MR8-9Q
MR20
MR8G98
Y8MRB-1
MR8-9Q
MR20
MR8G98
Y8MRB-1
MR8-9Q
MR20
Y8MRB-1
MY28
MR4C
Y2MR
MY28
Y2MR
MR4C
MY28
Y2MR
MR4C
Y2MR
MY28

TOOLS WITH DIES


Y29NC

NEST

INDENTOR

DV8L-1*

Y29PL

DV6L

Y29PL

DV4L

Y29PL

DV2L

Y29PL

* For aircraft applications (flexible cables).

26

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE QP-F
FEMALE FINGRIP
VINYL INSULATED
QUICK DISCONNECT
TERMINALS
Easy entry shroud has smooth funnel which
assures no hang up wire insertion. Color
coded for quick and easy identification. Two
piece construction.

Features and Benefits


Butted seam.
Insulated connectors.
Eliminate the need for post installation
insulation.
Funnel entry barrel opening.
Assures quick and easy wire insertion.
Dimpled female socket detent.
Ensures firm grip.

FEMALE VINYL DISCONNECT TERMINAL


STANDARD
CATALOG NO.

STD. PKG.
QTY.

WIRE
RANGE

100

18-22

100

14-16

50

10-12

QP18F18X02D
QP18F25X03D
QP14F18X02D
QP14F25X03D
QP10F25X03D
* For UL listed applications consult

BURNDY

NEMA TAB
SIZE
.187  .020
.250  .032
.187  .020
.250  .032
.250  .032

(Mates with Type QP-M male disconnects)


DIMENSIONS
A
B
W
0.86
0.91
0.87
0.92
1.08

0.17
0.17
0.17
0.17
0.27

0.22
0.29
0.23
0.29
0.29

BULK
CATALOG NO.
QP18F18X02B
QP18F25X03B
QP14F18X02B
QP14F25X03B
QP10F25X03B

BULK PKG.
QTY.
1000

INSTALLATION
TOOL*

Y10D

500

factory.

TYPE QP-M
MALE FINGRIP
VINYL INSULATED
QUICK DISCONNECT
TERMINAL
Easy entry shroud has smooth funnel which
assures no hang up wire insertion. Color
coded for quick and easy identification. Two
piece construction.

Features and Benefits


Butted seam.
Funnel entry barrel opening.
Assures quick and easy wire insertion.
Mates with dimpled female socket detent.
Ensures firm grip.

MALE VINYL DISCONNECT TERMINAL


STANDARD
CATALOG NO.
QP18M18X02D
QP18M25X03D
QP14M18X02D
QP14M25X03D
QP10M250D

STD. PKG.
QTY.

WIRE
RANGE

100

18-22

100

14-16

50

10-12

(Mates with Type QP-F female disconnects)

NEMA TAB
SIZE

.187  .020
.250  .032
.187  .020
.250  .032
.250  .032

0.83
0.95
0.83
0.95
1.12

DIMENSIONS
B
W
0.17
0.17
0.17
0.17
0.17

0.19
0.25
0.19
0.25
0.25

BULK
CATALOG NO.
QP18M18X02B
QP18M25X03B
QP14M18X02B
QP14M25X03B

BULK PKG.
QTY.

INSTALLATION
TOOL*

1000
1000

Y10D

* For UL listed applications consult BURNDY factory.

For CUSTOMER SERVICE call 1-800-346-4175

27

BURNDY
Telecommunications Products
TYPE QN-F
FINGRIP
NYLON INSULATED FEMALE
QUICK DISCONNECTS
MATERIAL: TIN-PLATED
BRASS
300 VOLTS MAX. 105C MAX.

Features and Benefits


Sleeved barrel.
Insulated connectors.
Eliminate the need for post installation
insulation.
Funnel entry barrel opening.
Assures quick and easy wire insertion.
Dimpled female socket detent.
Ensures firm grip.

FEMALE NYLON DISCONNECT TERMINAL


STANDARD
CATALOG NO.

STD. PKG.
QTY.

WIRE
RANGE

100

18-22

100

14-16

50

10-12

QN18F18X02D
QN18F25X03D
QN14F11X02D
QN14F18X02D
QN14F25X03D
QN10F25X03D
* For UL listed applications consult

BURNDY

(Mates with Type QN-M male disconnects)

NEMA TAB
SIZE

.187  .020
.250  .032
.110  .020
.187  .020
.250  .032
.250  .032

0.86
0.91
0.84
0.87
0.92
1.02

DIMENSIONS
B
W
0.17
0.17
0.17
0.17
0.17
0.27

0.22
0.29
0.14
0.23
0.29
0.29

BULK
CATALOG NO.
QN18F18X02B
QN18F25X03B
QN14F11X02B
QN14F18X02B
QN14F25X03B
QN10F25X03B

BULK PKG.
QTY.

1000

INSTALLATION
TOOL*

Y10D

500

factory.

TYPE QN-M
FINGRIP
NYLON INSULATED MALE
QUICK DISCONNECTS
MATERIAL: TIN-PLATED
BRASS
300 VOLTS MAX. 105 C MAX.

Features and Benefits


Sleeved barrel.
Funnel entry barrel opening.
Assures quick and easy wire insertion.
Mates with dimpled female socket detent.
Ensures firm grip.

MALE NYLON DISCONNECT TERMINAL


STANDARD
CATALOG NO.
QN18M18X02D
QN18M25X03D
QN14M18X02D
QN14M25X03D
NQ10M250D

STD. PKG.
QTY.

WIRE
RANGE

100

18-22

100

14-16

50

10-12

NEMA TAB
SIZE
.187  .020
.250  .032
.187  .020
.250  .032
.250  .032

(Mates with Type QN-F female disconnects)


DIMENSIONS
A
B
W
0.82
0.91
0.84
0.91
1.12

0.17
0.17
0.17
0.17
0.17

0.19
0.25
0.19
0.25
0.25

BULK
CATALOG NO.
QN18M18X02B
QN18M25X03B
QN14M18X02B
QN14M25X03B

BULK PKG.
QTY.

INSTALLATION
TOOL*

1000
1000

Y10D

* For UL listed applications consult BURNDY factory.

28

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES FQN-F AND
FQN-M FINGRIP
NYLON FULLY INSULATED
FEMALE AND MALE QUICK
DISCONNECTS

Fig. 1

MATERIAL: TIN-PLATED
BRASS
300 VOLTS MAX. 105 C MAX.
Features and Benefits
Fully insulated connectors.
Eliminate the need for post installation
insulation.
Funnel entry barrel opening.
Assures quick and easy wire insertion.
Dimpled female socket detent.
Ensures firm grip.

Fig. 2

FULLY INSULATED FEMALE NYLON DISCONNECT TERMINAL (Fig. 1)


STANDARD
CATALOG NO.

STD. PKG.
QTY.

WIRE
RANGE

NEMA TAB
SIZE

FQN18F25X03D
FQN14F25X03D
FQN10F25X03D

50
50
25

18-22
14-16
10-12

.250  .032
.250  .032
.250  .032

DIMENSIONS
A
W
0.98
0.96
0.99

0.40
0.40
0.41

BULK
CATALOG NO.

BULK PKG.
QTY.

FQN18F25X03B
FQN14F25X03B
FQN10F25X03B

1000
1000
500

INSTALLATION
TOOL*
Y10D

FULLY INSULATED MALE NYLON DISCONNECT TERMINAL (Fig. 2)


STANDARD
CATALOG NO.

STD. PKG.
QTY.

WIRE
RANGE

NEMA TAB
SIZE

FQN18M25X03D
FQN14M25X03D
FQN10M25X03D

50
50
25

18-22
14-16
10-12

.250  .032
.250  .032
.250  .032

DIMENSIONS
A
W
1.05
1.03
1.03

0.48
0.48
0.48

BULK
CATALOG NO.

BULK PKG.
QTY.

FQN18M25X03B
FQN14M25X03B
FQN10M25X03B

1000
1000
500

INSTALLATION
TOOL*
Y10D

* For UL listed applications consult BURNDY factory.


** For Mylar tape reels consult BURNDY factory.

For CUSTOMER SERVICE call 1-800-346-4175

29

BURNDY
Telecommunications Products
TYPE Q-M FINGRIP
NON-INSULATED MALE
QUICK DISCONNECTS
MATERIAL: TIN-PLATED
BRASS
Features and Benefits
Butted seam.
Chamfered barrel opening.
Assures quick and easy wire insertion.
Mates with dimpled female socket detent.
Ensures firm grip.

MALE BARE DISCONNECT TERMINAL


STANDARD
CATALOG NO.
Q18M18X02D
Q18M25X03D
Q14M18X02D
Q14M25X03D

STD. PKG.
QTY.

WIRE
RANGE

100

18-22

100

14-16

(Mates with Type Q-F female disconnects)

NEMA TAB
SIZE

.187  .020
.250  .032
.187  .020
.250  .032

0.55
0.67
0.55
0.67

DIMENSIONS
B
W
0.17
0.17
0.17
0.17

0.19
0.25
0.19
0.25

BULK
CATALOG NO.
Q18M18X02B
Q18M25X03B
Q14M18X02B
Q14M25X03B

BULK PKG.
QTY.
1000
1000

INSTALLATION
TOOL*
MR20,
Y10D

* For UL listed applications consult BURNDY factory.

TYPE Q-F FINGRIP


NON-INSULATED FEMALE
QUICK DISCONNECTS
MATERIAL: TIN-PLATED
BRASS
Features and Benefits
Butted seam.
Chamfered barrel opening.
Assures quick and easy wire insertion.
Dimpled female socket detent.
Ensures firm grip.

FEMALE BARE DISCONNECT TERMINAL


STANDARD
CATALOG NO.
Q18F18X02D
Q18F25X03D
Q14F11X02D
Q14F18X02D
Q14F25X03D
Q10F25X03D

STD. PKG.
QTY.

WIRE
RANGE

100

18-22

100

14-16

50

10-12

(Mates with Type Q-M male disconnects)

NEMA TAB
SIZE

.187  .020
.250  .032
.110  .020
.187  .020
.250  .032
.250  .032

0.58
0.62
0.55
0.58
0.62
0.73

DIMENSIONS
B
W
0.17
0.17
0.17
0.17
0.17
0.27

0.23
0.29
0.14
0.20
0.29
0.29

BULK
CATALOG NO.
Q18F18X02B
Q18F25X03B
Q14F11X02B
Q14F18X02B
Q14F25X03B
Q10F25X03B

BULK
QTY.

INSTALLATION
TOOL*

1000

MR20,
Y10D

500

* For UL listed applications consult BURNDY factory.

30

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
INTRODUCTION
MEDIUM AND LARGE HYDENT
Copper and aluminum compression terminals
and splices for terminating conductors from
#8 AWG through 2000 kcmil.
The medium and large HYDENT line is
designed for terminating and splicing medium
and large conductors in electrical power
applications.

HYLUG
UNINSULATED COPPER
COMPRESSION TERMINALS
UL LISTED 90C,
600 VOLT TO 35kV

BURNDY's HYLUG terminals, types YA,


YA-TC, YA-L, YA-L-TC, YA-2N, YA-2TC, YA-LTC-FX, YA-L-2TC and YA-2LN are designed
for terminating copper conductors in a wide
variety of electrical connections, including
heavy-duty industrial, utility, commercial and
telecommunications applications.
The HYLUG terminals require simple cable
preparation for an easily installed permanent
and inspectable cable termination. The terminals are listed by UL (UL STD.486A) and CSA
certified to 600 volt, when applied with the
proper tool and die combination. The terminals may be used in applications to 35kV.
See each catalog page for UL 35kV listings.

Features and Benefits


Manufactured from seamless high
conductivity electrolytic copper tubing
with heavy duty wall thickness.
Provides maximum conductivity, low
resistance and ductility for an excellent
combination of electrical and crimp
forming properties.
Barrel diameter closely matches
commercial (code) cable and navy
cable diameters.
Provides an excellent relationship
of the conductor/connector combination
to produce a high quality electrical connection with the recommended tooling.
Electro-tin plated. Electro-lead plated.
Burndys proprietary brite finish.
Provides durable long-lasting
corrosion resistance.
Internally beveled barrel end.
Provides easy cable insertion.
Each connector is clearly marked with
the wire size and type, die index, and
color coding.
Provides easy identification and proper
tooling recommendation.

Marked with the proper number and


location of crimps.
Lowers installed costs. Provides for
proper installations.
Proper compression systems forms a
homogenous mass.
The result is an excellent electrical
connection.
Use up to 35kV as indicated.
Suitable for high voltage applications.
Expanded wire ranges when using
Y644M HYPRESS Dieless 1 Crimp.
Provides ability to complete emergency
repairs when connector and wire size
do not match.
Crimp areas clearly marked.
Provides correct number and location
of crimps for proper installation.
Hydraulic and Battery tooling crimp
embossment.
Provides permanent die index number
embossment on completed crimp for
inspection purposes.

For applications greater than 2000 Volts, consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

31

BURNDY
Telecommunications Products
THE BURNDY SYSTEM

HYLUG Terminals

Installation System:
Connectors Match Conductors

Installation System

Die Set Embossment

32

Installation System:
Wire, Connector & Die
ALL Match

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
Page No.

Standard Barrel
Lugs

Stranded
Code
Class B
Cable

Long Barrel
Lugs

Copper
Splices

YA-L

34

One Hole Narrow Tongue

YA-L-NT

40

Two Hole

YA-L,YA-2L

68

Two Hole Narrow Tongue

YA-L-2NT

75

Twin Barrel

YAS-FX

One Hole

YA

41

One Hole with Inspection Window

YAZ

46

Two Hole

YA

76

Two Hole with Inspection Window

YAZ

82

Standard Barrel

YS-L

112

Long Barrel

YS

114

110

Thin Wall C-Taps

YC-L

119

C-Taps

YCHC

120

H-Taps

YH

121

One Hole

YAV-L-FX

50

One Hole Belled End

YA-LB

56

One Hole Lead Plated

YAG-L-TC-LD

57

Two Hole

YAV-L

89

Two Hole Lead Plated

YAG-L-LD

96

Twin Barrel

YAS-FX

110

One Hole Belled End

YAV-FXB

63

One Hole with Inspection Window

YAZV-FX, YAZ-FX

65

Two Hole Belled End

YAV-FXB

103

Two Hole with Inspection Window

YAZV-FX, YAZ-FX

105

Copper
Splices

Long Barrel Belled Ends

YS-FXB

115

Copper
Taps

H-Taps

YH

121

Copper
Taps

Standard Barrel
Lugs

Flexible
Extra Flex
Cable
Accepts Code
and Flex Cables
up to 4/0

One Hole

Long Barrel
Lugs

For CUSTOMER SERVICE call 1-800-346-4175

33

BURNDY
Telecommunications Products
ONE HOLE HYLUG
CODE CONDUCTOR
STANDARD BARREL

DIE AND COLOR


CODE INFORMATION

BEVELED
ENTRY

INSPECTION
WINDOW

TYPES YA-L, YA-L-TC

CRIMP

COPPER COMPRESSION
TERMINAL

ELECTRO-TIN
PLATED

CABLE
ACCOMMODATION

UL LISTED 90C,
600 VOLT TO 35 KV
B

B
90

B
T

45
L

Fig. 1

Conductor
Catalog Number
YAV10-45-BOX
YAV10-BOX
YAV10R-BOX
YAV10R3-BOX
YAV10T2-BOX
YAV10T3-45-BOX
YAV10T3-BOX
YAV10T4-BOX
YA8CL1-BOX
YA8CL1-45
YA8CL1-90
YA8CL2-BOX
YA8CL2-45
YA8CL2-90
YA8CL3-BOX
YA8CL3-45
YA8CL3-90
YA8CL4-BOX
YA8CL4-45
YA8CL4-90
YA8CL-BOX
YA8CL-45
YA8CL-90
YA6CL-BOX
YA6CL-45
YA6CL-90
YA6CL1-BOX
YA6CL1-45
YA6CL1-90
YA6CL3-BOX
YA6CL3-45
YA6CL3-90

Fig #
AWG
1
1
#14-#10
3
STR
3
1
#12-#10
2
SOL
1
1
1
2
3
1
2
#8 AWG
3
1
#8 WELD
2
3
37/24
1
2 #6 SOLID
3
1
2
3
1
2
3
1
2
#6 AWG
3
1
2
3

***
MM2

10

Stud
Hole
Size

Tongue
Width

8-10

.38

1/4
5/16
1/4
1/4
3/8

.47
.53
.47
.47
.56

Figure
Dimensions
(B)
(T)
.405 .058
.405 .058
.375 .058
.405 .047
.38 .047
.405 .047
.405 .047
.38 .047

1/4

.44

.44

.08

5/16

.52

.44

.06

3/8

.58

.44

.06

1/2

.71

.44

.05

8-10

.41

.44

.08

1/4

.45

.54

.08

8-10

.41
.41
.42

.54
.54
.54

.09
.09
.09

5/16

.52

.54

.07

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

34

Fig. 3

Fig. 2

Dieless
(L)
.92
1.02
.77
.83
1.12
1.10
1.10
1.18
1.26
1.24
.80
1.38
1.34
.92
1.51
1.45
1.04
1.76
1.67
1.28
1.16
1.16
.71
1.18
1.08
.81
.99
.89
.72
1.24
1.06
.93

(# of crimps)

Y8MRB-1 (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

7/16

Y1MR (1)
Y8MRB-1 (1)
W8CVT (1) W8CVT (1)
Y2MR (1)
W8CRT (1) W8CRT (1)
MY29-3 (1)
X8CRT (1) X8CRT (1)
MY29-11 (1)
MRC840 (1)

U8CRT (1)

Red

49

7/16

Y1MR (1)
W5CVT (1) W5CVT (1)
MY29-3 (1)
W5CRT (1) W5CRT (1)
MY29-11 (1)
X5CRT (1) X5CRT (1)
MRC840 (1)
X8CART (1) X8CART (1)
Y2MR (1)

U5CRT (1)

Blue

7/8

The MM2 conductor size listed is for both Class 2 and


Class 5 conductor.
See tooling section of this catalog for complete tool and die
listings.

Wire
Color Die Strip
Code Index Length

For applications greater than 2000 Volts, consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
YA6CL4-BOX
YA6CL4-45
YA6CL4-90
YA6CL6-BOX
YA6CL6-45
YA6CL6-90
YA5CL-BOX
YA5CL-45
YA5CL-90
YA4CL-BOX
YA4CL-45
YA4CL-90
YA4CL1-BOX
YA4CL1-45
YA4CL1-90
YA4CL3-BOX
YA4CL3-45
YA4CL3-90
YA4CL4-BOX
YA4CL4-45
YA4CL4-90
YA4CL6-BOX
YA4CL6-45
YA4CL6-90
YA3CL
YA3CL-45
YA3CL-90
YA2CL2-BOX
YA2CL2-45
YA2CL2-90
YA2CL-BOX
YA2CL-45
YA2CL-90
YA2CL4-BOX
YA2CL4-45
YA2CL4-90
YA2CL6-BOX
YA2CL6-45
YA2CL6-90
YA1CL2
YA1CL2-45
YA1CL2-90
YA1CL-BOX
YA1CL-45
YA1CL-90
YA1CL4-BOX
YA1CL4-45
YA1CL4-90
YA1CL6-BOX
YA1CL6-45
YA1CL6-90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

#6 AWG

#5 AWG

#4 AWG

# 3 STR
# 2 SOL

#2 AWG

#1 AWG

Stud
Hole
Size

Tongue
Width

3/8

.63

25

1/2

.75

1/4

.44

1/4

.50

8-10

.50

5/16

.58

3/8

.58

1/2

.71

5/16

.55

1/4

.61

5/16

.61

35
3/8

.61

1/2

.73

1/4

.68

5/16

.68

50
3/8

.68

1/2

.73

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

T
45

Fig. 1

Fig. 2

Conductor
***
MM2

B
90

B
T

Figure
Dimensions
(B)
(T)
(L)
1.28
.54
.06
1.17
1.05
1.60
.54
.12
1.54
1.30
1.65
.81
.07
1.31
.81
1.74
.81
.09
1.44
.84
1.58
.81
.09
1.28
.75
1.92
.81
.08
1.68
.96
1.92
.81
.08
1.68
1.08
2.20
.81
.06
2.02
1.32
1.88
.88
.09
1.76
.98
1.88
.88
.11
1.55
.89
1.93
.88
.11
1.62
1.01
2.06
.88
.11
1.74
1.14
2.32
.88
.09
2.17
1.37
1.81
.88
.10
1.70
.91
1.94
.88
.01
1.82
1.03
2.06
.88
.10
1.95
1.16
2.37
.88
.09
2.22
1.40

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

W5CVT (1) W5CVT (1)


Y1MR (1) W5CRT (1) W5CRT (1)
MY29-3 (1) X5CRT (1) X5CRT (1)
MY29-11 (1) X8CART (1) X8CART (1)
MRC840 (1)
Y2MR (1) W5CRT (1) W5CRT (1)
W5CVT (1) X5CRT (1)
X5CRT (1) W5CVT (1)

W4CVT (1) W4CVT (1)


W4CRT (1) W4CRT (1)
X4CRT (1) X4CRT (1)

Y1MR (2)
MY29-3 (1)
MY29-11 (1)
MRC840 (1)
Y2MR (2) W3CRT (1) W3CRT (1)
Y644M (1)

W2CVT (1) W2CVT (1)


W2CRT (1) W2CRT (1)
X2CRT (1) X2CRT (1)

Y1MR (2)
MY29-3 (1) W1CVT (1) W1CVT (1)
MY29-11 (1) W1CRT-1 (1) W1CRT-1 (1)
MRC840 (1) X1CRT-1 (1) X1CRT-1 (1)
Y644M (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.

For CUSTOMER SERVICE call 1-800-346-4175

Fig. 3
Wire
Color Die Strip
Code Index Length

U5CRT (1)
UBCABT (1)

Blue

7/8

U5CRT (1)

Blue

7/8

U4CRT (1)
U6CABT (1)

Gray

7/8

U3CRT (1)

White

15/16

U2CRT (1)

Brown

10

15/16

U1CRT-1 (1)
U4CABT (1)

Green

11

15/16

For applications greater than 2000 Volts, consult cable


manufacturer for voltage stress relief instructions.

35

BURNDY
Telecommunications Products

ONE HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
YA25L2-BOX
YA25L2-45
YA25L2-90
YA25L4-BOX
YA25L4-45
YA25L4-90
YA25L6-BOX
YA25L6-45
YA25L6-90
YA25L-BOX
YA25L-45
YA25L-90
YA26L2-BOX
YA26L2-45
YA26L2-90
YA26L3-BOX
YA26L3-45
YA26L3-90
YA26L-BOX
YA26L-45
YA26L-90
YA26L60
YA26L60-45
YA26L60-90
YA26L6-BOX
YA26L6-45
YA26L6-90
YA26L7-BOX
YA26L7-45
YA26L7-90
YA26LNT516
YA27L2-BOX
YA27L2-45
YA27L2-90
YA27L3
YA27L3-45
YA27L3-90
YA27L4-BOX
YA27L4-45
YA27L4-90
YA27L-BOX
YA27L-45
YA27L-90
YA27LNT38
YA28L17-BOX
YA28L17-45
YA28L17-90
YA28L2-BOX
YA28L2-45

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2

AWG

1/0 AWG

2/0 AWG

3/0 AWG

4/0 AWG

Stud
Hole
Size

Tongue
Width

1/4

.75

3/8

.75

1/2

.75

5/16

.75

1/4

.83

5/16

.83

3/8

.83

70
3/4

.96

1/2

.83

5/8

.88

5/16

.62

1/4

1.00

5/16

.91

3/8

.91

1/2

.91

3/8

.76

5/8

1.02

1/4

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

36

T
45

Fig. 1

Fig. 2

Conductor
***
MM2

B
90

B
T

1.02

Figure
Dimensions
(B)
(T)
(L)
1.84
.88
.12
1.76
.94
2.09
.88
.12
2.01
1.19
2.34
.88
.12
2.26
1.44
1.96
.88
.12
1.88
1.07
1.94
.94
.12
1.78
.96
2.06
.94
.12
1.91
1.09
2.19
.94
.12
2.03
1.21
2.96
.94
.12
2.77
1.89
2.44
.94
.12
2.28
1.46
2.69
.94
.11
2.50
1.71
.94
.13
2.62
2.04
1.00 .13
1.91
.99
2.16
1.00 .13
2.03
1.12
2.29
1.00 .13
1.91
.99
2.54
1.00 .13
2.41
1.49
1.00 .12
2.73
2.71
.88
.14
2.64
1.79
1.96
.88
.14
1.89

Dieless
(# of crimps)

MY29-3 (1)
MY29-11 (1)
MRC840 (2)
Y644M (1)

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W25VT (2) W25VT (2)


W25RT (2) W25RT (2)
X25RT (2) X25RT (2)

U25RT (1)
U2CABT (1)

Pink

12

15/16

W26VT (2) W26VT (2)


W26RT (2) W26RT (2)
X26RT (2) X26RT (2)

U26RT (1)

Black

13

1

W27VT (2) W27VT (2)


W27RT (2) W27RT (2)
X27RT (3) X27RT (3)

U27RT (1)

Orange

14 1-1/16

W28VT (2) W28VT (2)


W28RT (2) W28RT (2)
X28RT (3) X28RT (3)

U28RT (1)

Purple

15

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.

1-1/8

For applications greater than 2000 Volts, consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
YA28L2-90
YA28L3-BOX
YA28L3-45
YA28L3-90
YA28L4-BOX
YA28L4-45
YA28L4-90
YA28L56-BOX
YA28L56-45
YA28L56-90
YA28L-BOX
YA28L-45
YA28L-90
YA28LNT38
YA29L2
YA29L2-45
YA29L2-90
YA29L4
YA29L4-45
YA29L4-90
YA29L7
YA29L7-45
YA29L7-90
YA29LTC78
YA29LTC78-45
YA29LTC78-90
YA29LNT38
YA29L-BOX
YA29L-45
YA29L-90
YA30L
YA30L-45
YA30L-90
YA30L1
YA30L1-45
YA30L1-90
YA30L24
YA30L24-45
YA30L24-90
YA30L27
YA30L27-45
YA30L27-90
YA30L28
YA30L7
YA30L7-45
YA30L7-90
YA31L
YA31L-45
YA31L-90

Fig #
AWG
3
1
2
3
1
2
3
4/0 AWG
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
250 kcmil
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
300 kcmil
3
1
2
3
1
1
2
3
1
2
350 kcmil
3

Stud
Hole
Size
1/4

Tongue
Width
1.02

5/16

1.02

3/8

1.02

3/4

1.05

1/2

1.02

3/8

.76

1/4

1.11

3/8

1.11

5/16

1.11

7/8

1.11

3/8

.96

1/2

1.11

1/2

1.20

5/16

1.20

3/8

1.20

7/8

1.20

3/4

1.20

5/8

1.20

1/2

1.29

150

185

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

T
45

Fig. 1

Fig. 2

Conductor
***
MM2

B
90

B
T

Figure
Dimensions
(B)
(T)
(L)
.88
.14
1.04
2.08
.88
.14
2.01
1.16
2.21
.88
.14
2.14
1.29
2.90
.88
.13
2.81
1.97
2.46
.88
.14
2.39
1.54
.88
.16
2.79
2.17
1.06 .16
2.07
1.08
2.42
1.06 .16
2.32
1.33
2.30
1.06 .16
2.20
1.20
3.36
1.06 .14
3.23
2.26
1.06 .16
2.96
2.67
1.06 .16
2.57
1.58
2.69
1.03 .16
2.60
1.61
2.31
1.03 .16
2.22
1.24
2.44
1.03 .16
2.35
1.36
3.37
1.03 .16
3.29
2.30
1.03 .16
3.12
2.94
1.03 .16
2.85
1.86
2.75
1.06 .18
2.75
1.65

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

MY29-3 (1)
W28VT (2) W28VT (2)
MY29-11 (1)
W28RT (2) W28RT (2)
MRC840 (2)
X28RT (2) X28RT (3)
Y644M (1)

U28RT (1)

Purple

15

1-1/8

MY29-3 (1)
W29VT (2)
MY29-11 (1)
X29RT (4)
Y644M (1)

W29VT (2)
W29RT (2)
X29RT (4)

U29RT (1)

Yellow

16

1-1/8

W30VT (2)

W30VT (2)
W30RT (2)

U30RT (2)
U28ART (2)

White

17 1-1/16

W31VT (2)

W31VT (2)
W31RT (2)

U31RT (2)
U29ART (2)

Red

18 1-3/16

Y644M (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.

For CUSTOMER SERVICE call 1-800-346-4175

Fig. 3

For applications greater than 2000 Volts, consult cable


manufacturer for voltage stress relief instructions.

37

BURNDY
Telecommunications Products

ONE HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
YA31L11
YA31L11-45
YA31L11-90
YA31L36
YA31L36-45
YA31L36-90
YA31L7
YA31L7-45
YA31L7-90
YA31LNT38
YA32L
YA32L-45
YA32L-90
YA32L1
YA32L1-45
YA32L1-90
YA32L14
YA32L14-45
YA32L14-90
YA32LTC78
YA32LTC78-45
YA32LTC78-90
YA33L
YA33L-45
YA33L-90
YA34L
YA34L-45
YA34L-90
YA34L20
YA34L20-45
YA34L20-90
YA34L37
YA34L37-45
YA34L37-90
YA34L6
YA34L6-45
YA34L6-90
YA34L8
YA34L8-45
YA34L8-90
YA34L9
YA34L9-45
YA34L9-90
YA35L
YA35L-45
YA35L-90
YA36L11
YA36L
YA36L-45
YA36L-90

Fig #
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3

AWG

350 kcmil

400 kcmil

450 kcmil

500 kcmil

550 kcmil

600 kcmil

185

Stud
Hole
Size

Tongue
Width

3/8

1.29

7/8

1.29

5/8

1.29

3/8

96

5/8

1.38

1/2

1.40

3/8

1.38

7/8

1.40

5/8

1.48

5/8

1.55

1

1.55

3/8

1.55

240

300

1/2

1.55

3/4

1.55

7/8

1.55

5/8

1.65

1/2

1.74

5/8

1.74

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

38

T
45

Fig. 1

Fig. 2

Conductor
***
MM2

B
90

B
T

Figure
Dimensions
(B)
(T)
(L)
2.50
1.06 .18
2.42
1.40
4.02
1.06 .18
4.02
3.94
3.00
1.06 .18
3.00
1.90
1.06 .18
3.37
3.18
1.19 .19
3.08
1.95
2.93
1.19 .19
2.83
1.70
2.68
1.19 .19
2.58
1.45
3.62
1.19 .19
3.52
2.38
3.57
1.50 .21
3.30
2.00
3.37
1.27 .23
3.30
2.03
4.05
1.27 .23
3.99
2.72
2.87
1.27 .23
2.80
1.53
3.12
1.27 .23
3.05
1.78
3.55
1.27 .23
3.49
2.22
3.80
1.27 .23
3.74
2.47
3.81
1.69 .25
3.67
2.08
1.38 .27
3.29
3.72
1.38 .27
3.51
2.11

Dieless
(# of crimps)

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W31VT (2)

W31VT (2)
W31RT (2)

U31RT (2)
U29ART (2)

Red

18 1-3/16

W32VT (2)

W32VT (2)
W32RT (2)

U32RT (2)
U30ART (2)

Blue

19

W33VT (2)

W33VT (2)
W33RT (2)

U33RT (2)

Gray

326 1-9/16

W34VT (2)

W34VT (2)
W34RT (2)

U34RT (2)
U31ART (2)

Brown

20 1-7/16

U35RT (2)

Yellow

21

1-3/4

U36RT (2)

Green

22

1-3/4

1-1/4

Y644M (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.

For applications greater than 2000 Volts, consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Fig #
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

Stud
Hole
Size

Tongue
Width

600 kcmil

300

7/8

1.74

650 kcmil

5/8

1.80

700 kcmil

5/8

1.84

5/8

1.91

7/8

1.91

750 kcmil

1-1/4 1.91
3/8

1.12

1/2

1.91

800 kcmil

400

5/8

1.98

850 kcmil

5/8

2.01

5/8

2.19

1000 kcmil

500
1/2
1

2.49
2.19

1250 kcmil

3/4

2.46

1300 kcmil

3/4

2.53

1500 kcmil

3/4

2.69

1750 kcmil

3/4

2.90

2000 kcmil

3/4

3.10

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

T
45

Fig. 1

Fig. 2

Conductor
Catalog Number
YA36LTC78
YA36LTC78-45
YA36LTC78-90
YA37L
YA37L-45
YA37L-90
YA37L1
YA38L
YA38L-90
YA38L-45
YA39L
YA39L-45
YA39L-90
YA39L2
YA39L2-45
YA39L2-90
YA39L9
YA39L9-45
YA39L9-90
YA39LNT38
YA39L6
YA39L6-45
YA39L6-90
YA40L
YA40L-45
YA40L-90
YA41L
YA41L-45
YA41L-90
YA44L
YA44L-45
YA44L-90
YA44L2
YA44L23
YA-45L
YA-45L-45
YA-45L-90
YA-453L
YA-453L-45
YA-453L-90
YA46L
YA46L-45
YA46L-90
YA47L
YA47L-45
YA47L-90
YA48L
YA48L-45
YA48L-90

B
90

B
T

Figure
Dimensions
(B)
(T)
(L)
3.97
1.38 .27
3.95
2.55
3.57
3.55
1.39 .27
2.14
3.76
3.66
1.45 .27
3.60
2.15
3.67
1.42 .27
3.61
2.17
4.10
1.42 .27
4.05
2.61
4.85
1.42 .27
4.80
3.36
1.42 .27
4.70
3.41
1.42 .27
3.36
1.92
3.81
1.42 .30
3.69
2.21
4.15
1.88 .31
4.03
2.23
4.04
1.65 .33
4.01
2.32
1.65 .33
3.98
1.65 .33
4.73
4.68
2.00 .38
4.64
2.62
4.71
2.00 .39
4.68
2.65
4.78
2.00 .40
4.75
2.71
5.05
2.19 .42
5.00
2.79
5.19
2.25 .46
5.19
2.89

Dieless
(# of crimps)

Y644M (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

U36RT (2)
U32ART (2)

Green

22

1-3/4

U37RT (2)

Orange

23

1-15/16

U38RT (2)

Pink

400 1-15/16

U39RT (2)
P39RT (2)
**

Black

24

1-15/16

P40RT(3)
**

Orange

25

1-15/16

Gold

26

1-15/16

P44RT(3)
**

White

27

1-15/16

P45RT(3)
**

Yellow

29

2-1/16

Orange

30

2-1/16

P46RT (3)
**
-

Green

31

2-1/16

Gray

33

2-1/4

Brown

34

2-1/4

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.

For CUSTOMER SERVICE call 1-800-346-4175

Fig. 3

For applications greater than 2000 Volts, consult cable


manufacturer for voltage stress relief instructions.

39

BURNDY
Telecommunications Products
ONE HOLE HYLUG
CODE CONDUCTOR
STANDARD BARREL
NARROW TONGUE

DIE AND COLOR


CODE INFORMATION

BEVELED
ENTRY

INSPECTION
WINDOW

TYPES YA-L-NT

CRIMP
ELECTRO-TIN
PLATED

COPPER COMPRESSION
NARROW TONGUE
TERMINAL

CABLE
ACCOMMODATION

UL Listed 90 C,
600 Volts to 35 KV
B

90

B
T

T
45
L

Fig. 1

Fig. 2

Fig. 3

Conductor
Catalog Number

Fig #

AWG

YA8CLNT6

#8 AWG

YA6CLNT6
YA4CLNT10

1
1

YA3CLNT516

#6 AWG
#4 AWG
#3 AWG
#2 SOL

YA2CLNT10
YA2CLNT14
YA2CLNT516
YA1CLNT10
YA1CLNT14
YA25LNT10
YA25LNT516
YA26LNT10
YA26LNT516
YA26LNT516U
YA26LNT38
YA27LNT38
YA28LNT38
YA29LNT38
YA29LENT38
YA30LNT38
YA31LNT38
YA32LNT38
YA34LNT38
YA36LNT38
YA39LNT38

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

***
MM2

Stud
Hole
Size

**
10

.29

.44

.09

1.08

6
# 10

.29
.40

.54
.81

.09
.09

1.17
1.73

25

5/16

.49

.88

.09

1.80

.48
.50
.49
.50
.50
.62
.62
.62
.62
.62
.72
.76
.76
.96
.76
.96
.96
.96
.96
1.12
1.12

.88
.88
.88
.88
.88
.88
.88
.94
.94
.94
.94
1.00
.88
1.06
1.06
1.03
1.06
1.19
1.27
1.38
1.42

.11
.11
.11
.10
.10
.12
.12
.13
.13
.13
.12
.12
.14
.16
.16
.16
.18
.20
.23
.27
.27

1.80
1.80
1.82
2.23
2.23
2.28
2.28
2.62
2.62
2.62
2.48
2.73
2.67
2.96
2.96
2.97
3.31
3.21
3.65
4.09
4.24

2/0 AWG

70

3/0 AWG
4/0 AWG

# 10
1/4
5/16
# 10
1/4
# 10
5/16
# 10
5/16
3/8
3/8
3/8

250 kcmil

3/8

300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
750 kcmil

150
185
240
300
-

3/8
3/8
3/8
3/8
3/8
3/8

*
#2 AWG

35

#1 AWG

50

1/0 AWG

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** The MM2 conductor size listed is for Class 2 and Class 5
conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

40

Tongue
Width

Figure
Dimensions
(B)
(T)
(L)

****
Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Y8MRB-1 (1)
Y2MR (1)
MY29-3 (1) W8CVT (1) X8CRT (1)
MY29-11 (1)
MRC840 (1)
Y1MR (1)
Y2MR (1)
MY29-3 (1)
MY29-11 (1)
MRC840 (1)
Y644M (1)

Wire
Color Die Strip
Code Index Length

U8CRT (1)

Red

49

1/2

W5CVT (1) X5CRT (1)


W4CVT (1) X4CRT (1)
W3CVT (1) W3CVT (1)

U5CRT (1)
U4CRT (1)
U3CRT (1)

Blue
Gray
White

7
8
9

7/8
7/8
15/16

W2CVT (1) X2CRT (1)

U2CRT (1)

Brown

10

15/16

W1CVT (1) X1CRT (1)

U1CRT (1)

Green

11

15/16

W25VT (2)

X25RT (2)

U25RT (1)

Pink

12

15/16

X26RT (2)

U26RT (1)

Black

13

1

X27RT (3)
X28RT (3)
X29RT (4)
X29RT (4)
-

U27RT (1)
U28RT (1)
U29RT (1)
U29RT (1)
U30RT (2)
U31RT (2)
U32RT (2)
U34RT (2)
U36RT (2)
U39RT (2)

Orange
Purple
Yellow
Yellow
White
Red
Blue
Brown
Green
Black

14 1-1/16
15 1-1/8
16 1-1/8
16 1-1/8
17 1-1/8
18 1-3/16
19 1-1/4
20 1-7/16
22 1-3/4
24 1-15/16

MY29-3 (1)
MY29-11 (1)
W26VT (2)
MRC840 (1)
Y644M (1)
W27VT (2)
W28VT (2)
W29VT (2)
W29VT (2)
W30VT (4)
W31VT (4)
W32VT (4)
Y644M (1)
W34VT (4)
-

**** Y644M is not recommended for standard barrel length #6


AWG HYLUGs.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FXconnectors. For nest/indentor system contact factory.

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
ONE HOLE HYLUG
CODE CONDUCTOR
LONG BARREL

BEVELED
ENTRY

DIE AND COLOR


CODE INFORMATION
NO INSPECTION
WINDOW

TYPES YA, YA-TC


CRIMPS

UNINSULATED COPPER
COMPRESSION TERMINAL

CABLE
ACCOMMODATION

ELECTRO-TIN
PLATED

UL Listed 90 C,
600 Volts to 35 KV
B

B
90

B
T

T
45

Conductor
Catalog Number
YA8C-TC10
YA8C-TC10-45
YA8C-TC10-90
YA8C-TC14
YA8C-TC14-45
YA8C-TC14-90
YA8C-TC38
YA8C-TC38-45
YA8C-TC38-90
YA6C-TC10
YA6C-TC10-45
YA6C-TC10-90
YA6C-N
YA6C-N-45
YA6C-N-90
YA6C
YA6C-45
YA6C-90
YA5C
YA5C-45
YA5C-90
YA5C-N
YA5C-N-45
YA5C-N-90
YA4C-TC10
YA4C-TC10-45
YA4C-TC10-90
YA4C
YA4C-45

Fig #
AWG
1
2
#8 AWG
3
1
#8 WELD
2
3
37/24
1
2
#6 SOL
3
1
2
3
1
2
#6 AWG
3
1
2
3
1
2
3
#5 AWG
1
2
3
1
2
3
#4 AWG
1
2

***
MM2

10

Stud
Hole
Size

Tongue
Width

# 10

.38

1/4

.41

3/8

.58

# 10

.41

1/2

.83

1/4

.41

1/4

.44

1/2

.83

# 10

.49

1/4

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

.50

Fig. 1

Fig. 2

Fig. 3

Figure
Dimensions
(B)
(T)
(L)
1.57
.81
.08
1.46
.68
1.69
.81
.08
1.57
.86
1.88
.81
.06
1.71
1.04
1.89
1.12 .09
1.72
.75
2.64
1.12 .12
2.53
1.52
1.81
1.12 .09
1.24
.81
1.98
1.12 .07
1.75
.81
2.67
1.12 .12
2.55
1.52
1.94
1.12 .09
1.94
1.75
1.87
1.12 .09
1.52

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

MRC840 (2)
W8CVT (2) X8CRT (2)
Y8MBR-1 (1)
W8CRT (2) W8CVT (2)
Y2MR (2)
X8CRT (2) W8CRT (2)
Y1MR (2)

U8CRT (2)

Red

49

1

MRC840 (2)
MY29-3 (2) W5CVT (2) W5CVT (2)
MY29-11 (2) W5CRT (2) W5CRT (2)
Y2MR (2)
X5CRT (2) X5CRT (2)
Y644M (1) X8CART (2) X8CART (2)
Y1MR (1)

U5CRT (2)
U8CABT (2)

Blue

1-3/16

W5CVT (2) W5CVT (2)


W5CRT (2) W5CRT (2)
X5CRT (2) X5CRT (2)

U5CRT (2)

Blue

1-3/16

W4CVT (2) W4CVT (2)


W4CRT (2) W4CRT (2)
X4CRT (2) X4CRT (2)

U4CRT (2)
U6CABT (2)

Gray

1-3/16

Y1MR (1)
MRC840 (2)
MY29-3 (2)
MY29-11 (2)
Y2MR (2)
Y644M (1)
MRC840 (2)
MY29-3 (2)
MY29-11 (2)
Y2MR (4)
Y644M (1)

The MM2 conductor size listed is for Class 2 and Class 5


conductor.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for "FX" connectors. For nest/indentor system contact factory.

For CUSTOMER SERVICE call 1-800-346-4175

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

41

BURNDY
Telecommunications Products

Conductor
Catalog Number
YA4C-90
YA4C-TC38
YA4C-TC38-45
YA4C-TC38-90
YA4C-N
YA4C-N-45
YA4C-N-90
YA3C-TC14
YA3C-TC14-45
YA3C-TC14-90
YA3C
YA3C-45
YA3C-90
YA3C-TC38
YA3C-TC38-45
YA3C-TC38-90
YA3CN
YA3CN-45
YA3CN-90
YA2C-TC10
YA2C-TC10-45
YA2C-TC10-90
YA2C-TC14
YA2C-TC14-45
YA2C-TC14-90
YA2C
YA2C-45
YA2C-90
YA2C-N
YA2C-N-45
YA2C-N-90
YA1C-TC10
YA1C-TC10-45
YA1C-TC10-90
YA1C
YA1C-45
YA1C-90
YA1C-N
YA1C-N-45
YA1C-N-90
YA25TC10
YA25TC10-45
YA25TC10-90
YA25
YA25-45
YA25-90
YA25TC38
YA25TC38-45
YA25TC38-90

Fig #
AWG
3
1
2
3
#4 AWG
1
2
3
1
2
3
1
2
#3 AWG
3
1 #2 SOLID
2
3
1
2
3
1
2
3
1
2
3
#2 AWG
1
2
3
1
2
3
1
2
3
1
2
#1 AWG
3
1
2
3
1
2
3
1
2
1/0 AWG
3
1
2
3

***
MM2

T
45

Stud
Hole
Size
1/4

Tongue
Width
.56

3/8

.58

1/2

.83

1/4

.55

5/16

.55

3/8

.61

1/2

.81

# 10

.61

1/4

.60

35
5/16

.61

1/2

.83

# 10

.68

5/16

.68

1/2

.83

# 10

.75

5/16

.75

3/8

.75

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

42

25

90

50

ONE HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)
Figure
Dimensions
(B)
(T)
(L)
1.12 .09
.84
2.25
1.12 .08
2.02
1.08
2.69
1.12 .12
2.56
1.54
2.23
1.25 .09
1.99
.92
2.30
1.25 .09
2.05
.98
2.42
1.25 .08
2.16
1.10
2.86
1.25 .12
2.68
1.56
2.10
1.25 .11
1.90
.82
2.23
1.25 .11
2.02
.95
2.29
1.25 .11
2.09
1.01
2.88
1.25 .12
2.70
1.58
2.27
1.38 .10
2.00
.84
2.45
1.38 .10
2.19
1.03
3.06
1.38 .12
2.82
1.60
2.30
1.38 .12
2.06
.88
2.48
1.38 .12
2.25
1.07
2.61
1.38 .12
2.37
1.19

Fig. 1

Fig. 2

Dieless
(# of crimps)

T
L

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Fig. 3
Wire
Color Die Strip
Code Index Length

MRC840 (2)
MY29-3 (2)
W4CVT (2) W4CVT (2)
MY29-11 (2)
W4CRT (2) W4CRT (2)
Y2MR (4)
X4CRT (2) X4CRT (2)
Y644M (1)
Y1MR (4)

U4CRT (2)
U6CABT (2)

Gray

1-3/16

MY29-3 (2)
MY29-11 (2) W3CRT (2) W3CRT (2)
Y644M (1)

U3CRT (2)

White

1-1/2

Y1MR (4)
MRC840 (2)
W2CVT (2) W2CVT (2)
MY29-3 (2)
W2CRT (2) W2CRT (2)
MY29-11 (2)
X2CRT (2) X2CRT (2)
Y2MR (4)
Y644M (1)

U2CRT (2)

Brown

10 1-5/16

Y1MR (4)
MRC840 (2) W1CVT (2) W1CVT (2)
MY29-3 (2) W1CRT-1 (2) W1CRT-1 (2)
MY29-11 (2) X1CRT-1 (2) X1CRT-1 (2)
Y644M (1)

U1CRT-1 (2)
U4CABT (2)

Green

11 1-7/16

MRC840 (4)
W25VT (4) W25VT (4)
MY29-3 (2)
W25RT (4) W25RT (4)
MY29-11 (2)
X25RT (4) X25RT (4)
Y644M (1)

U25RT (2)
U2CABT (2)

Pink

12 1-7/16

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

Conductor
Catalog Number
YA25N

Fig #
1

AWG
1/0
AWG

YA25N-45

YA25N-90
YA26
YA26-45
YA26-90
YA26N
YA26N-45
YA26N-90
YA27

3
1
2
3
1
2
3
1

2/0
AWG

YA27-45

3/0 AWG

YA27-90
YA28TC38
YA28TC38-45
YA28TC38-90
YA28
YA28-45
YA28-90
YA29
YA29-45
YA29-90
YA30
YA30-45
YA30-90
YA31
YA31-45
YA31-90
YA32N
YA32N-45
YA32N-90
YA32
YA32-45
YA32-90

3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

***
MM2
-

Stud
Hole
Size
1/2

3/8

Tongue
Width
.81

.83

Figure
Dimensions
(B)
(T)
(L)
3.05
1.38

1.50

.11

.12

1/2

.83

1.50

.12

1/2

.91

1.50

.13

1.02

1.62

.14

1/2

250 kcmil

1/2

1.11

1.62

.16

300 kcmil

150

1/2

1.20

2.00

.16

350 kcmil

185

1/2

1.29

2.00

.18

1/2

1.38

2.12

.19

400 kcmil

5/8

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

T
45

3/8
4/0 AWG

90

70

ONE HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)

1.38

2.12

.19

2.79
1.62
2.77
2.49
1.22
3.21
2.93
1.65
3.06
2.78
1.49
2.98
2.68
1.29
3.23
2.93
1.54
3.26
2.99
1.58
3.69
3.31
1.61
3.73
3.36
1.65
4.09
3.71
1.88
4.15
3.77
1.95

Fig. 1

Fig. 2

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Fig. 3
Wire
Color Die Strip
Code Index Length

MRC840 (4)
W25VT(4) W25VT (4)
MY29-3 (2)
W25RT (4) W25RT (4)
MY29-11 (2)
X25RT (4) X25RT (4)
Y644M (1)

U25RT (2)
U2CABT (2)

Pink

12

1-7/16

MRC840 (4)
W26VT (4) W26VT (4)
MY29-3 (2)
W26RT (4) W26RT (4)
MY29-11 (2)
X26RT (4) X26RT (4)
Y644M (1)

U26RT (2)

Black

13

1-9/16

MRC840 (4)
W27VT (4) W27VT (4)
MY29-3 (2)
W27RT (4) W27RT (4)
MY29-11 (2)
X27RT (6) X27RT (6)
Y644M (1)

U27RT (2)

Orange

14

1-9/16

MRC840 (4)
W28VT (4) W28VT (4)
MY29-3 (2)
W28RT (4) W28RT (4)
MY29-11 (2)
X28RT (6) X28RT (6)
Y644M (1)

U28RT (2)

Purple

15

1-1/16

MY29-3 (2)
W29VT (4)
MY29-11 (2)
X29RT (8)
Y644M (1)

W29VT (4)
W29RT (4)
X29RT (8)

U29RT (2)

Yellow

16

1-1/16

Y644M (1)

W30VT (4)

W30VT (4)
W30RT (4)

U30RT (4)
U28ART (4)

White

17 or
2-1/16
298

Y644M (1)

W31VT (4)

W31VT (4)
W31RT (4)

U31RT (4)
U29ART (4)

Red

18 or
2-1/16
324

Y644M (1)

W32VT (4)

W32VT (4)
W32RT (4)

U32RT (4)
U30ART (4)

Blue

19 or
2-3/16
470

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.

For CUSTOMER SERVICE call 1-800-346-4175

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

43

BURNDY
Telecommunications Products

Conductor
Catalog Number
YA33
YA33-45
YA33-90
YA33-N
YA33-N-45
YA33-N-90
YA34N
YA34N-45
YA34N-90
YA34
YA34-45
YA34-90
YA35
YA35-45
YA35-90
YA35-N
YA35-N-45
YA35-N-90
YA36N
YA36N-45
YA36N-90
YA36
YA36-45
YA36-90
YA37
YA37-45
YA37-90
YA37-N
YA37-N-45
YA37-N-90
YA38
YA38-45
YA38-90
YA38-N
YA38-N-45
YA38-N-90
YA39N
YA39N-45
YA39N-90
YA39
YA39-45
YA39-90
YA40
YA40-45
YA40-90
YA40-N
YA40-N-45
YA40-N-90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

450 kcmil

500 kcmil

550 kcmil

600 kcmil

***
MM2

650 kcmil

700 kcmil

750 kcmil

800 kcmil

1.48

1/2

1.48

1/2

1.52

240
5/8

1.52

5/8

1.65

1/2

1.65

1/2

1.69

300
1.69

5/8

1.80

1/2

1.80

5/8

1.84

1/2

1.84

1.89

5/8

1.89

5/8

1.98

400
1/2

T
45

5/8

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

44

Tongue
Width

1/2

90

Stud
Hole
Size

5/8

ONE HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)

1.98

Figure
Dimensions
(B)
(T)
(L)
4.24
2.13 .21
3.87
2.00
4.17
2.13 .21
3.81
1.94
4.32
2.25 .23
3.96
1.97
4.39
2.25 .23
4.02
2.03
4.79
2.63 .25
4.37
2.08
4.73
2.63 .25
4.30
2.01
4.83
2.69 .27
4.41
2.05
4.90
2.69 .27
4.47
2.11
5.05
2.81 .27
4.59
2.14
4.98
2.81 .27
4.53
2.08
5.07
2.81 .27
4.60
2.15
5.01
2.81 .27
4.53
2.08
5.11
2.88 .27
4.62
2.11
5.17
2.88 .27
4.68
2.17
5.25
2.94 .30
4.80
2.21
5.19
2.94 .30
4.74
2.15

Fig. 1

Fig. 2

Dieless
(# of crimps)

T
L

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
-

Fig. 3
Wire
Color Die Strip
Code Index Length

W33VT (4)

W33VT (4)
W33RT (4)

U33RT (4)

Gray

326 or
2-5/16
538

W34VT (4)

W34VT (4)
W34RT (4)

U34RT (4)
U31ART (4)

Brown

20 or
2-5/16
299

U35RT (4)

Yellow

U36RT (4)
U32ART (4)

Green

U37RT (4)

Orange

23

2-7/8

U38RT (4)

Pink

400

2-7/8

21

2-11/16

22 or
2-3/4
472

Y644M (1)

See tooling section of this catalog for complete tool and


die listings. Use ONLY color coded die recommendations
for "-FX" connectors. For nest/indentor system contact
factory.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).

U39RT (4)
P39RT (4)
**

Black

24

2-15/16

P40RT (4)
**

Orange

25

3

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

Conductor
Catalog Number
YA41
YA41-45
YA41-90
YA41-N
YA41-N-45
YA41-N-90
YA44
YA44-45
YA44-90
YA44-N
YA44-N-45
YA44-N-90
YA45
YA45-45
YA45-90
YA45-N
YA45-N-45
YA45-N-90
YA46
YA46-45
YA46-90
YA46-N
YA46-N-45
YA46-N-90
YA47
YA47-45
YA47-90
YA47-N
YA47-N-45
YA47-N-90
YA48
YA48-45
YA48-90
YA48-N
YA48-N-45
YA48-N-90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

850 kcmil

***
MM2

1000 kcmil

1250 kcmil

1500 kcmil

1750 kcmil

2000 kcmil

5/8

2.01

2.01

2.17

500
1/2

2.19

3/4

2.46

1/2

2.46

3/4

2.69

1/2

2.69

3/4

2.90

1/2

2.90

3/4

3.10

1/2

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.

45

Tongue
Width

5/8

90

Stud
Hole
Size

1/2

ONE HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)

3.10

Figure
Dimensions
(B)
(T)
(L)
5.26
2.94 .31
4.82
2.23
5.20
2.91 .31
4.76
2.17
5.45
3.00 .33
5.01
2.32
5.38
3.00 .33
4.95
2.26
5.93
3.19 .38
5.52
2.62
5.68
3.19 .38
5.27
2.37
6.04
3.19 .40
5.64
2.71
5.79
3.19 .40
5.39
2.46
6.38
3.44 .42
5.94
2.79
6.13
3.44 .42
5.69
2.54
6.47
3.44 .46
6.09
2.89
6.22
3.44 .46
5.84
2.64

Fig. 1

Fig. 2

Dieless
(# of crimps)

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

Gold

26

3

P44RT (4)
**

White

27 3-1/16

P45RT (6)
**

Yellow

29

P46RT (6)
**

Green

31 3-5/16

Gray

33

3-1/2

Brown

34

3-1/2

Y644M (1)

3-1/4

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

45

BURNDY
Telecommunications Products
ONE HOLE HYLUG
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW

DIE AND COLOR


CODE INFORMATION

BEVELED
ENTRY

INSPECTION
WINDOW

TYPE YAZ

CRIMP

UNINSULATED COPPER
COMPRESSION TERMINAL

CABLE
ACCOMMODATION

ELECTRO-TIN
PLATED

UL Listed 90 C,
600 Volts to 35 kV
B
90

B
T

Conductor
Catalog Number
YAZV10-TC14
YAZV10-TC14-45
YAZV10-TC14-90
YAZ8C-TC10
YAZ8C-TC10-45
YAZ8C-TC10-90
YAZ8C-TC14
YAZ8C-TC14-45
YAZ8C-TC14-90
YAZ8C-TC38
YAZ8C-TC38-45
YAZ8C-TC38-90
YAZ6C-TC14
YAZ6C-TC14-45
YAZ6C-TC14-90
YAZ6C-TC38
YAZ6C-TC38-45
YAZ6C-TC38-90
YAZ6C-TC12
YAZ6C-TC12-45
YAZ6C-TC12-90
YAZ5C-TC12
YAZ5C-TC12-45
YAZ5C-TC12-90
YAZ4C-TC14
YAZ4C-TC14-45
YAZ4C-TC14-90
YAZ4C-TC38
YAZ4C-TC38-45
YAZ4C-TC38-90
YAZ4C-TC12
YAZ4C-TC12-45
YAZ4C-TC12-90

Fig #
AWG
1
#14 - 10 Str
2
#12 - 10 Sol
3
1
2
3
#8 AWG
1
#8 WELD
2
37/24
3
#6 SOL
1
2
3
1
2
3
1
2
#6 AWG
3
1
2
3
1
2
#5 AWG
3
1
2
3
1
2
#4 AWG
3
1
2
3

***
MM2

Stud
Hole
Size

1/4

.41
.

#10

.41

1/4

.44

1/4

.58

1/4

.45
.

10

3/8

.58

1/2

1/2

.83
.
.
.83

1/4

.49

3/8

.58

1/2

.83

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

46

Tongue
Width

45

Fig. 1

Fig. 2

Fig. 3

Figure
Dimensions
(B)
(T)
(L)
1.54
.69
.05
1.41
.83
1.58
.75
.08
1.47
.75
1.71
.75
.08
1.58
.87
1.89
.75
.06
1.72
1.05
2.03
1.12 .08
1.83
.89
2.22
1.12 .06
1.97
1.06
2.65
1.12 .12
2.54
1.53
2.68
1.12 .12
2.56
1.53
2.05
1.12 .09
1.87
.92
2.23
1.12 .08
2.01
1.09
2.67
1.12 .12
2.55
1.55

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Y8MRB-1

Wire
Color Die Strip
Code Index Length

3/4

U8CRT (2)

Red

49

7/8

W5CVT (2)
W5CRT (2)
X5CRT (2)
X8CART (2)

U5CRT (2)
U8CABT (2)

Blue

7 or
1-3/16
374

W5CRT (2) W5CVT (2)


W5CVT (2) X5CRT (2)
X5CRT (2) W5CRT (2)

U5CRT (2)

Blue

7 or
1-3/16
374

Y1MR (4)
Y2MR (4)
W4CVT (2) W4CVT (2)
MY29-3 (2)
W4CRT (2) W4CRT (2)
MY29-11 (2)
X4CRT (2) X4CRT (2)
MRC840 (2)
Y644M (1)

U4CRT (2)
U6CABT (2)

Gray

8 or
1-3/16
346

W8CVT (2) W8CVT (2)


W8CRT (2) W8CRT (2)
X8CRT (2) X8CRT (2)
Y1MR (2)
Y2MR (2)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
W5CVT (2)
Y644M (1)
W5CRT (2)
X5CRT (2)
X8CART (2)

The MM2 conductor size listed is for Class 2 and Class 5


conductor.
See tooling section of this catalog for complete tool and
die listings.

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

Conductor
Catalog Number
YAZ3C-TC14
YAZ3C-TC14-45
YAZ3C-TC14-90
YAZ3C-TC38
YAZ3C-TC38-45
YAZ3C-TC38-90
YAZ3C-TC12
YAZ3C-TC12-45
YAZ3C-TC12-90
YAZ2C-TC14
YAZ2C-TC14-45
YAZ2C-TC14-90
YAZ2C-TC38
YAZ2C-TC38-45
YAZ2C-TC38-90
YAZ2C-TC12
YAZ2C-TC12-45
YAZ2C-TC12-90
YAZ1C-TC14
YAZ1C-TC14-45
YAZ1C-TC14-90
YAZ1C-TC38
YAZ1C-TC38-45
YAZ1C-TC38-90
YAZ1C-TC12
YAZ1C-TC12-45
YAZ1C-TC12-90
YAZ25-TC14
YAZ25-TC14-45
YAZ25-TC14-90
YAZ25-TC516
YAZ25-TC516-45
YAZ25-TC516-90
YAZ25-TC38
YAZ25-TC38-45
YAZ25-TC38-90
YAZ25-TC12
YAZ25-TC12-45
YAZ25-TC12-90
YAZ26-TC14
YAZ26-TC14-45
YAZ26-TC14-90
YAZ26-TC38
YAZ26-TC38-45
YAZ26-TC38-90
YAZ26-TC12
YAZ26-TC12-45
YAZ26-TC12-90
YAZ27-TC38
YAZ27-TC38-45
YAZ27-TC38-90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

ONE HOLE HYLUG


CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)

Stud
Hole
Size

Tongue
Width

1/4

.55

3/8

.58

1/2

.83

1/4

.60

3/8

.60

1/2

.83

1/4

.67

#3 AWG
25
#2 SOL

#2 AWG

#1 AWG

1/0 AWG

2/0 AWG

3/0 AWG

35

50

3/8

.67

1/2

.83

1/4

.75

5/16

.75

70

3/8

.75

1/2

.83

1/4

.83

3/8

.83

1/2

.83

3/8

.90

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

B
90

Figure
Dimensions
(B)
(T)
(L)
2.21
1.25 .09
1.97
.93
2.39
1.25 .08
2.13
1.11
2.83
1.25 .07
2.66
1.57
2.23
1.25 .11
2.03
.96
2.41
1.25 .11
2.21
1.14
2.85
1.25 .09
2.57
1.57
2.39
1.38 .10
2.13
.98
2.57
1.38 .10
2.31
1.16
3.01
1.38 .09
2.7
1.59
2.42
1.38 .12
2.19
1.02
2.47
1.38 .12
2.24
1.08
2.6
1.38 .12
2.37
1.2
3.04
1.38 .12
2.77
1.63
2.58
1.50 .12
2.3
1.04
2.76
1.50 .12
2.48
1.22
3.2
1.50 .12
2.92
1.66
2.8
1.50 .12
2.52
1.25

T
L

Fig. 1

Fig. 2

T
L

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W3CRT (2) W3CRT (2)

U3CRT (2)

White

1-5/16

W2CVT (2) W2CVT (2)


W2CRT (2) W2CRT (2)
X2CRT (2) X2CRT (2)

U2CRT (2)

Brown

10

1-5/16

Y1MR (4)
MY29-3 (2) W1CVT (2) W1CVT (2)
MY29-11 (2) W1CRT-1 (2) W1CRT-1 (2)
MRC840 (2) X1CRT-1 (2) X1CRT-1 (2)
Y644M (1)

U1CRT-1 (2)
U4CABT (2)

Green

11 or
1-7/16
375

W25VT (4) W25VT (4)


W25RT (4) W25RT (4)
X25RT (4) X25RT (4)

U25RT (2)
U2CABT (2)

Pink

12 or
1-7/16
348

W26VT (4) W26VT (4)


W26RT (4) W26RT (4)
X26RT (4) X26RT (4)

U26RT (2)

Black

13 1-9/16

W27RT (4) W27VT (4)


W27VT (4) W27RT (4)
X27RT (6) X27RT (6)

U27RT (2)

Orange

14 1-9/16

Dieless
(# of crimps)

Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
Y644M (1)

MY29-3 (2)
MY29-11 (2)
MRC840 (4)
Y644M (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.

For CUSTOMER SERVICE call 1-800-346-4175

45

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

47

BURNDY
Telecommunications Products

Conductor
Catalog Number
YAZ27-TC12
YAZ27-TC12-45
YAZ27-TC12-90
YAZ28-TC38
YAZ28-TC38-45
YAZ28-TC38-90
YAZ28-TC12
YAZ28-TC12-45
YAZ28-TC12-90
YAZ29-TC38
YAZ29-TC38-45
YAZ29-TC38-90
YAZ29-TC12
YAZ29-TC12-45
YAZ29-TC12-90
YAZ30-TC38
YAZ30-TC38-45
YAZ30-TC38-90
YAZ30-TC12
YAZ30-TC12-45
YAZ30-TC12-90
YAZ31-TC38
YAZ31-TC38-45
YAZ31-TC38-90
YAZ31-TC12
YAZ31-TC12-45
YAZ31-TC12-90
YAZ32-TC38
YAZ32-TC38-45
YAZ32-TC38-90
YAZ32-TC12
YAZ32-TC12-45
YAZ32-TC12-90
YAZ33-TC12
YAZ33-TC12-45
YAZ33-TC12-90
YAZ34-TC38
YAZ34-TC38-45
YAZ34-TC38-90
YAZ34-TC12
YAZ34-TC12-45
YAZ34-TC12-90
YAZ35-TC12
YAZ35-TC12-45
YAZ35-TC12-90
YAZ36-TC38
YAZ36-TC38-45
YAZ36-TC38-90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

Tongue
Width

3/0 AWG

1/2

.91

3/8

1.02

4/0 AWG
-

250 kcmil

300 kcmil

350 kcmil

1/2

1.02

3/8

1.10

1/2

1.10

3/8

1.20

150
1/2

1.20

3/8

1.29

185

1/2

1.29

3/8

1.40

400 kcmil

450 kcmil

500 kcmil

B
90

Stud
Hole
Size

1/2

1.40

1/2

1.48

3/8

1.55

240
1/2

1.55

550 kcmil

1/2

1.65

600 kcmil

300

3/8

1.74

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

48

ONE HOLE HYLUG


CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Figure
Dimensions
(B)
(T)
(L)
3.23
1.5 0.12 2.96
1.69
2.99
1.62 0.14 2.69
1.3
3.4
1.62 0.14 3.11
1.73
2.99
1.62 0.16 2.73
1.34
3.43
1.62 0.16 3.17
1.77
3.42
2
.16
3.04
1.37
3.85
2
.16
3.48
1.81
3.45
2
0.18
3.1
1.41
3.89
2
0.18 3.54
1.85
3.62
2.12 .19
3.25
1.46
4.06
2.12 .19
3.69
1.89
4.14
2.12 .21
3.79
1.95
3.85
2.25 .23
3.5
1.54
4.29
2.25 .23
3.94
1.98
4.7
2.62 .25
4.28
2.02
4.55
2.69 .26
4.14
1.81

45

Fig. 1

Fig. 2

Dieless
(# of crimps)

Mechanical
MD6, OUR840,
MD7-34R
W27RT (4)
W27VT (4)
X27RT (6)

Fig. 3

Installation Tooling
Hydraulic
BCT500HS,
Y35,Y39,Y750,
Y500CTHS
Y46*, PAT750
W27VT (4)
W27RT (4)
U27RT (2)
X27RT (6)

MY29-3 (2)
MY29-11 (2)
MRC840 (4) W28VT (4) W28VT (4)
Y644M (1) W28RT (4) W28RT (4)
X28RT (6) X28RT (6)

Wire
Color Die Strip
Code Index Length
Orange 14 1-9/16

U28RT (2)

Purple

15 1-11/16

MY29-3 (2)
W29VT (4)
MY29-11 (2)
X29RT (8)
Y644M (1)

W29VT (4)
W29RT (4)
X29RT (6)

U29RT (2)

Yellow

16 1-11/16

W30VT (4)

W30VT (4)
W30RT (4)

U30RT (4)
U28ART (4)

White

17 or
2-1/16
298

W31VT (4)

W31VT (4)
W31RT (4)

U31RT (4)
U29ART (4)

Red

18 or
2-1/16
324

W32VT (4)

W32VT (4)
W32RT (4)

U32RT (4)
U30ART (4)

Blue

19 or
2-3/16
470

W33VT (4)

W33VT (4)
W33RT (4)

U33RT (4)

Gray

326 2-5/16

W34VT (4)

W34VT (4)
W34RT (4)

U34RT (4)
U31ART (4)

Brown

20 or
2-5/16
299

U35RT (4)

Yellow

21 2-11/16

U36RT (4)
U32ART (4)

Green

Y644M (1)

See tooling section of this catalog for complete tool and


die listings.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).

22 or
472

2/4

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

Conductor
Catalog Number
YAZ36-TC12
YAZ36-TC12-45
YAZ36-TC12-90
YAZ37-TC12
YAZ37-TC12-45
YAZ37-TC12-90
YAZ38-TC12
YAZ38-TC12-45
YAZ38-TC12-90
YAZ39-TC38
YAZ39-TC38-45
YAZ39-TC38-90
YAZ39-TC12
YAZ39-TC12-45
YAZ39-TC12-90
YAZ39-NT12
YAZ39-NT12-45
YAZ39-NT12-90
YAZ40-TC12
YAZ40-TC12-45
YAZ40-TC12-90
YAZ41-TC12
YAZ41-TC12-45
YAZ41-TC12-90
YAZ44-TC38
YAZ44-TC38-45
YAZ44-TC38-90
YAZ44-TC12
YAZ44-TC12-45
YAZ44-TC12-90
YAZ45-TC12
YAZ45-TC12-45
YAZ45-TC12-90
YAZ453-TC12
YAZ453-TC12-45
YAZ453-TC12-90
YAZ46-TC12
YAZ46-TC12-45
YAZ46-TC12-90
YAZ47-TC12
YAZ47-TC12-45
YAZ47-TC12-90
YAZ48-TC12
YAZ48-TC12-45
YAZ48-TC12-90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

ONE HOLE HYLUG


CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)

AWG

***
MM2

Stud
Hole
Size

Tongue
Width

600 kcmil

300

1/2

1.74

650 kcmil

1/2

1.80

700 kcmil

1/2

1.84

3/8

1.91

1/2

1.91

750 kcmil

1/2

1.63

800 kcmil

400

1/2

1.98

850 kcmil

1/2

2.01

3/8

2.19

1000 kcmil

500
1/2

2.19

1250 kcmil

1/2

2.46

1300 kcmil

1/2

2.53

1500 kcmil

1/2

2.69

1750 kcmil

1/2

2.90

2000 kcmil

1/2

3.10

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.

B
90

Figure
Dimensions
(B)
(T)
(L)
4.80
2.69 .26
4.39
2.06
4.95
2.81 .27
4.51
2.09
4.97
2.81 .27
4.51
2.09
4.82
2.88 .27
4.34
1.87
5.07
2.88 .27
4.59
2.12
5.07
2.88 .27
4.59
2.12
5.14
2.94 .30
4.71
2.16
5.16
2.94 .31
4.73
2.18
5.09
3.00 .33
4.66
2.02
5.33
3.00 .33
4.91
2.27
5.63
3.19 .38
5.24
2.38
5.66
3.19 .39
5.28
2.41
5.73
3.19 .40
5.35
2.47
6.07
3.44 .42
5.65
2.55
6.14
3.44 .46
5.79
2.65

T
L

Fig. 1

Fig. 2

Dieless
(# of crimps)

45

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

22 or
472

U36RT (4)

Green

U37RT (4)

Orange 23

U38RT (4)

Pink

400 2-7/8

U39RT (4)
P39RT (4)
**

Black

24 2-15/16

P40RT (4)
**

P45RT (6)
**

P46RT (6)
**

Green

31 3-5/16

Gray

33

3-1/2

Brown

34

3-1/2

Y644M (1)

Wire
Color Die Strip
Code Index Length
2/4

2-7/8

Orange 25

3

Gold

26

3

P44RT (4)
**

White

27 3-1/16

Yellow

29

3-1/4

Orange 30 2-1/16

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

49

BURNDY
Telecommunications Products
ONE HOLE HYLUG
FLEX CONDUCTOR
STANDARD BARREL

DIE AND COLOR


CODE INFORMATION

BEVELED
ENTRY

INSPECTION
WINDOW

TYPES YA-L, YA-L-FX, YAV,


YAV-L-FX

CRIMP
ELECTRO-TIN
PLATED

CABLE
ACCOMMODATION

COPPER COMPRESSION
TERMINAL

UL Listed 90 C,
600 Volts to 35 kV
B

90
T

T
45

Conductor
Catalog Number
Fig #
AWG
YA8CL-BOX
1
YA8CL-45
2
YA8CL-90
3
YA8C-L1-BOX
1
YA8C-L1-45
2
YA8C-L1-90
3
37/24
YA8C-L2-BOX
1
YA8C-L2-45
2
#8 Weld
YA8C-L2-90
3
YA8C-L3-BOX
1
#8 AWG
YA8C-L3-45
2
YA8C-L3-90
3
YA8C-L4-BOX
1
YA8C-L4-45
2
YA8C-L4-90
3
YAV6CL-TC10-FX
1
YAV6CL-TC10-FX-45
2
YAV6CL-TC10-FX-90
3
YAV6CL-TC12-FX
1
YAV6CL-TC12-FX-45
2
YAV6CL-TC12-FX-90
3
61/24
YAV6CL-TC14-FX
1
YAV6CL-TC14-FX-45
2
#6 WELD
YAV6CL-TC14-FX-90
3
YAV6CL-TC38-FX
1
#6 AWG
YAV6CL-TC38-FX-45
2
YAV6CL-TC38-FX-90
3
YAV6CL-TC516-FX
1
YAV6CL-TC516-FX-45 2
YAV6CL-TC516-FX-90 3

***
MM2

Stud
Hole
Size

Tongue
Width

8-10

.41

1/4

.44

5/16

.52

3/8

.58

1/2

.71

8-10

.48

1/2

.75

**
10

**
1/4

.48

3/8

.60

5/16

.60

16

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** The MM2 conductor size listed is for both Class 2 and
Class 5 conductors.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

50

Fig. 1

Fig. 2

Fig. 3

Figure
Dimensions
(B)
(T)
(L)
1.16
.44
.08
1.16
.71
1.26
.44
.08
1.24
.80
1.38
.44
.08
1.34
.92
1.51
.44
.08
1.45
1.04
1.76
.44
.08
1.67
1.28
1.30
.50
.08
1.26
.76
1.86
.50
.12
1.92
1.34
1.43
.50
.08
1.39
.88
1.61
.50
.06
1.54
1.06
1.49
.50 0.07 1.44
.94

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

Y1MR (1)
W8CVT (1) W8CVT (1)
Y8MRB-1
W8CRT (1) W8CRT (1)
Y2MR (1)
X8CRT (1) X8CRT (1)
MY29-11 (1)

U8CRT (1)

Red

49

7/16

Y1MR (1)
W5CVT (1) W5CVT (1)
Y2MR (1)
W5CRT (1) W5CRT (1)
MY29-11 (1)
X5CRT (1) X5CRT (1)
Y644M (1)

U5CRT (1)

Blue

1/2

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
Fig #
YAV6CL-TC34-FX
1
YAV6CL-TC34-FX-45
2
YAV6CL-TC34-FX-90
3
YAV4CL-TC10-FX
1
YAV4CL-TC10-FX-45
2
YAV4CL-TC10-FX-90
3
YAV4CL-TC12-FX
1
YAV4CL-TC12-FX-45
2
YAV4CL-TC12-FX-90
3
YAV4CL-TC14-FX
1
YAV4CL-TC14-FX-45
2
YAV4CL-TC14-FX-90
3
YAV4CL-TC38-FX
1
YAV4CL-TC38-FX-45
2
YAV4CL-TC38-FX-90
3
YAV4CL-TC516-FX
1
YAV4CL-TC516-FX-45 2
YAV4CL-TC516-FX-90 3
YAV2CL-TC10-FX
1
YAV2CL-TC10-FX-45
1
YAV2CL-TC10-FX-90
1
YAV2CL-TC12-FX
1
YAV2CL-TC12-FX-45
1
YAV2CL-TC12-FX-90
1
YAV2CL-TC14-FX
1
YAV2CL-TC14-FX-45
2
YAV2CL-TC14-FX-90
3
YAV2CL-TC38-FX
1
YAV2CL-TC38-FX-45
2
YAV2CL-TC38-FX-90
3
YAV2CL-TC516-FX
1
YAV2CL-TC516-FX-45 2
YAV2CL-TC516-FX-90 3
YAV1CL-TC10-FX
1
YAV1CL-TC10-FX-45
2
YAV1CL-TC10-FX-90
3
YAV1CL-TC12-FX
3
YAV1CL-TC12-FX-45
2
YAV1CL-TC12-FX-90
3
YAV1CL-TC14-FX
2
YAV1CL-TC14-FX-45
3
YAV1CL-TC14-FX-90
3
YAV1CL-TC38-FX
1
YAV1CL-TC38-FX-45
2
YAV1CL-TC38-FX-90
3
YAV1CL-TC516-FX
1
YAV1CL-TC516-FX-45
2
YAV1CL-TC516-FX-90
3

AWG
61/24
#6 WELD
#6 AWG

***
MM2
**
16

91/24

Tongue
Width

3/4

1.05

10-8

.55

1/2

.71

1/4

.55

3/8

.58

5/16

.55

# 10

.68

1/2

.77

1/4

.68

3/8

.68

5/16

.68

# 10

.75

1/2

.75

1/4

.75

3/8

.75

5/16

.75

#4 WELD
#4 AWG

125/24
150/24
35
#2 WELD
#2 AWG

175/24
225/24
#1 WELD
#1 AWG

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


** The 16 MM2 is for both Class 2 and Class 5 conductors.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

T
45

105/24
-

90
T

T
L

Fig. 1

Fig. 2

Fig. 3

Conductor
Stud
Hole
Size

Figure
Dimensions
(B)
(T)
(L)
2.30
.50
.13
2.39
1.78
1.32
.50
.09
1.30
.79
1.92
.50
.07
1.84
1.34
1.44
.50
.09
1.43
.92
1.67
.50
.08
1.63
1.10
1.51
.50
.09
1.49
.98
1.50
.63
.10
1.46
.84
2.12
.63 0.09 2.03
1.40
1.62
.63
.10
1.58
.97
1.81
.63
.10
1.77
1.15
1.69
.63
.10
1.65
1.03
1.59
.69
.12
1.56
.88
2.15
.69
.12
2.12
144
1.71
.69
.12
1.69
1.00
1.90
.69
.12
1.87
1.19
1.78
.69
.12
1.75
1.07

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

Y2MR (1)
MY29-11 (1) W5CVT (1) X5CRT (1)
Y644M (1)

U5CRT (1)

Blue

1/2

W4CVT (1) W4CVT (1)


W4CRT (1) W4CRT (1)
X4CRT (1) X4CRT (1)

U4CRT (1)

Gray

1/2

W2CVT (1) W2CVT (1)


W2CRT (1) W2CRT (1)
X2CRT (1) X2CRT (1)

U2CRT (1)

Brown

10

11/16

W1CVT (1) W1CVT (1)


MY29-11 (1)
W1CRT-1 (1) W1CRT-1 (1)
Y644M (1)
X1CRT-1 (1) X1CRT-1 (1)

U1CRT (1)

Green

11

11/16

Y1MR (2)
Y2MR (2)
MY29-11 (1)
Y644M (1)

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

51

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
Fig #
AWG
YAV25L-TC12-FX
1
YAV25L-TC12-FX-45
2
YAV25L-TC12-FX-90
3
YAV25L-TC14-FX
1
275/24
YAV25L-TC14-FX-45
2
YAV25L-TC14-FX-90
3
1/0 WELD
YAV25L-TC38-FX
1
YAV25L-TC38-FX-45
2
1/0 AWG
YAV25L-TC38-FX-90
3
YAV25L-TC516-FX
1
YAV25L-TC516-FX-45 2
YAV25L-TC516-FX-90 3
YAV26L-TC10-FX
1
YAV26L-TC10-FX-45
2
YAV26L-TC10-FX-90
3
YAV26L-TC12-FX
1
YAV26L-TC12-FX-45
2
YAV26L-TC12-FX-90
3
YAV26L-TC14-FX
1
YAV26L-TC14-FX-45
2
YAV26L-TC14-FX-90
3
325/24
YAV26L-TC34-FX
1
YAV26L-TC34-FX-45
2 2/0 WELD
YAV26L-TC34-FX-90
3
YAV26L-TC38-FX
1
2/0 AWG
YAV26L-TC38-FX-45
2
YAV26L-TC38-FX-90
3
YAV26L-TC516-FX
1
YAV26L-TC516-FX-45 2
YAV26L-TC516-FX-90 3
YAV26L-TC58-FX
1
YAV26L-TC58-FX-45
1
YAV26L-TC58-FX-90
1
YAV27L-TC10-FX
1
YAV27L-TC10-FX-45
2
YAV27L-TC10-FX-90
3
YAV27L-TC12-FX
1
YAV27L-TC12-FX-45
2
YAV27L-TC12-FX-90
3
450/24
YAV27L-TC14-FX
1
YAV27L-TC14-FX-45
2 3/0 WELD
YAV27L-TC14-FX-90
3
YAV27L-TC38-FX
1
3/0 AWG
YAV27L-TC38-FX-45
2
YAV27L-TC38-FX-90
3
YAV27L-TC516-FX
1
YAV27L-TC516-FX-45 2
YAV27L-TC516-FX-90 3

95

Stud
Hole
Size

Tongue
Width

1/2

.83

1/4

.83

3/8

.83

5/16

.83

# 10

.93

1/2

.93

1/4

.93

3/4

1.10

3/8

.93

5/16

.93

5/8

.93

# 10

1.03

1/2

1.03

1/4

1.03

3/8

1.03

5/16

1.03

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

52

T
45

50

70

90
T

T
L

Fig. 1

Fig. 2

Fig. 3

Conductor
***
MM2

Figure
Dimensions
(B)
(T)
(L)
2.19
.69
.12
2.15
1.47
1.75
.69
.12
1.71
1.03
1.94
.69
.12
1.90
1.22
1.81
.69
.12
1.77
1.09
1.80
.81
.13
1.73
.94
2.36
.81
.13
2.29
1.51
1.92
.81
.13
1.85
1.07
2.89
.81
.11
2.75
1.93
2.11
.81
.13
2.04
1.26
1.98
.81
.13
1.92
1.13
2.61
.81
.13
2.54
1.76
2.03
1.00 .14
1.91
.98
2.59
1.00 .14
2.47
1.54
2.15
1.00 .14
2.04
1.10
2.34
1.00 .14
2.22
1.29
2.21
1.00 .14
2.10
1.17

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

W25VT (2) W25VT (2)


W25RT (2) W25RT (2)
X25RT (2) X25RT (2)

W26VT (2) W26VT (2)


W26RT (2) W26RT (2)
MY29-11 (1) X26RT (2) X26RT (2)
Y644M (1)

W27VT (2) W27VT (2)


W27RT (2) W27RT (2)
X27RT (3) X27RT (3)

Wire
Color Die Strip
Code Index Length

U25RT (1)

Pink

12

11/16

U26RT (1)

Black

13

13/16

U27RT (1)

Orange 14

1

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
Fig #
YAV28L-TC12-FX
1
YAV28L-TC12-FX-45
2
YAV28L-TC12-FX-90
3
YAV28L-TC14-FX
1
YAV28L-TC14-FX-45
2
YAV28L-TC14-FX-90
3
YAV28L-TC34-FX
1
YAV28L-TC34-FX-45
2
YAV28L-TC34-FX-90
3
YAV28L-TC38-FX
1
YAV28L-TC38-FX-45
2
YAV28L-TC38-FX-90
3
YAV28L-TC516-FX
2
YAV28L-TC516-FX-45 2
YAV28L-TC516-FX-90 3
YAV28L-TC58-FX
1
YAV28L-TC58-FX-45
2
YAV28L-TC58-FX-90
3
YAV29L-TC12-FX
1
YAV29L-TC12-FX-45
2
YAV29L-TC12-FX-90
3
YAV29L-TC14-FX
1
YAV29L-TC14-FX-45
2
YAV29L-TC14-FX-90
3
YAV29L-TC34-FX
1
YAV29L-TC34-FX-45
2
YAV29L-TC34-FX-90
3
YAV29L-TC38-FX
1
YAV29L-TC38-FX-45
2
YAV29L-TC38-FX-90
3
YAV29L-TC516-FX
2
YAV29L-TC516-FX-45 2
YAV29L-TC516-FX-90 3
YAV29L-TC58-FX
1
YAV29L-TC58-FX-45
2
YAV29L-TC58-FX-90
3
YA30L-TC516-FX
1
YA30L-TC516-FX-45
2
YA30L-TC516-FX-90
3
YA30L-TC38-FX
1
YA30L-TC38-FX-45
2
YA30L-TC38-FX-90
3
YA30L-TC12-FX
1
YA30L-TC12-FX-45
2
YA30L-TC12-FX-90
3
YA30L-TC58-FX
1
YA30L-TC58-FX-45
2
YA30L-TC58-FX-90
3

AWG

550/24
4/0 WELD

550/24

Stud
Hole
Size

Tongue
Width

1/2

1.14

1/4

1.14

3/4

1.14

3/8

1.14

5/16

1.14

5/8

1.14

1/2

1.14

1/4

1.14

3/4

1.14

3/8

1.14

5/16

1.14

4/0 WELD

5/8

1.14

5/16

1.20

3/8

1.20

1/2

1.20

5/8

1.20

250 FLEX
CLASS G
259 STR.

CLASS H
427 STR.

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


** The 120 MM2 referenced here is for both Class 2 and
Class 5.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

T
45

**
120

4/0 AWG

90
T

T
L

Fig. 1

Fig. 2

Fig. 3

Conductor
***
MM2

Figure
Dimensions
(B)
(T)
(L)
2.67
1.03 0.15
254
1.58
2.23
1.03 .15
2.11
1.14
3.11
1.03 .15
2.98
2.02
2.42
1.03 .15
2.29
1.33
2.29
1.03 .15
2.17
1.21
2.92
1.03 .15
2.79
1.83
2.67
1.03 .16
254
1.58
2.23
1.03 .16
2.11
1.14
3.11
1.03 .16
2.98
2.02
2.42
1.03 .16
2.29
1.33
2.29
1.03 .16
2.17
1.21
2.92
1.03 .16
2.79
1.83
2.31
1.03 .16
2.22
1.24
2.44
1.03 .16
2.35
1.36
2.69
1.03 .16
2.60
1.61
2.94
1.03 .16
2.85
1.86

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W28VT (2) W28VT (2)


MY29-11 (1)
W28RT (2) W28RT (2)
Y644M (1)
X28RT (2) X28RT (3)

U28RT (1)

Purple 15 1-1/16

W29VT (2)
W29RT (2)
X29RT (4)

U29RT (1)

Yellow

Y644M (1)

W29VT (2)
X29RT (4)

16 1-1/16

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

53

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG
250 FLEX
CLASS G 259 STR.
CLASS H 427 STR

***
MM2

Tongue
Width

3/4

1.20

1/4

1.29

5/16

1.29

3/8

1.29

1/2

.96

1/2

1.29

5/8

1.29

3/4

1.29

CLASS I, K, M

3/8

1.40

1/2

1.40

5/8

1.40

5/16

1.55

3/8

1.55

313.1 KCMIL
775/24

185

300 FLEX

373.7 KCMIL
925/24

240

350 FLEX

444.4 KCMIL
450 FLEX

1/2

1.55

5/8

1.55

1/2

1.74

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

54

Fig. 1

Stud
Hole
Size

150

T
45

250 FLEX
637/24

90

Conductor
Catalog Number
YA30L-TC34-FX
YA30L-TC34-FX-45
YA30L-TC34-FX-90
YA31L-TC14-FX
YA31L-TC14-FX-45
YA31L-TC14-FX-90
YA31L-TC516-FX
YA31L-TC516-FX-45
YA31L-TC516-FX-90
YA31L-TC38-FX
YA31L-TC38-FX-45
YA31L-TC38-FX-90
YA31L-NT12-FX
YA31L-NT12-FX-45
YA31L-NT12-FX-90
YA31L-TC12-FX
YA31L-TC12-FX-45
YA31L-TC12-FX-90
YA31L-TC58-FX
YA31L-TC58-FX-45
YA31L-TC58-FX-90
YA31L-TC34-FX
YA31L-TC34-FX-45
YA31L-TC34-FX-90
YA32L-TC38-FX
YA32L-TC38-FX-45
YA32L-TC38-FX-90
YA32L-TC12-FX
YA32L-TC12-FX-45
YA32L-TC12-FX-90
YA32L-TC58-FX
YA32L-TC58-FX-45
YA32L-TC58-FX-90
YA34L-TC516-FX
YA34L-TC516-FX-45
YA34L-TC516-FX-90
YA34L-TC38-FX
YA34L-TC38-FX-45
YA34L-TC38-FX-90
YA34L-TC12-FX
YA34L-TC12-FX-45
YA34L-TC12-FX-90
YA34L-TC58-FX
YA34L-TC58-FX-45
YA34L-TC58-FX-90
YA36L-TC12-FX
YA36L-TC12-FX-45
YA36L-TC12-FX-90

Figure
Dimensions
(B)
(T)
(L)
3.12
1.03 .16
3.04
2.05
2.31
1.06 .18
2.23
1.19
2.37
1.06 .18
2.30
1.27
2.50
1.06 .18
2.42
1.40
2.75
1.06 .18
2.67
1.65
2.75
1.06 .18
2.67
1.65
3.00
1.06 .18
2.92
1.90
3.19
1.06 .18
3.11
2.09
2.68
1.19 .19
2.58
1.45
2.93
1.19 .19
2.83
1.70
3.18
1.19 .19
3.08
1.95
2.74
1.27 .23
2.68
1.41
2.87
1.27 .23
2.80
1.53
3.12
1.27 .23
3.05
1.78
3.37
1.27 .23
3.30
2.03
3.29
1.38 .27
3.26
1.86

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
X29RT (4)
W29VT (2)
W29VT (2)
U29RT (1)
X29RT (4)
W29RT (2)

Wire
Color Die Strip
Code Index Length
Yellow

16 1-1/16

W30VT (2)

W30VT (2)
W30RT (2)

U30RT (2)

White

17

1-1/8

W31VT (2)

W31VT (2)
W31RT (2)

U31RT (2)

Red

18

1-1/4

W32VT (2)

W32VT (2)
W32RT (2)

U32RT (2)

Blue

19 1-5/16

U34RT (2)

Brown 20

Y644M (1)

1-3/8

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Fig #
AWG
1
2
1100/24
3
1
2
3
1
535.3 KCMIL
2
3
1325/24
1
2
500 FLEX
3
1
2
3
1
2
3
1
2
646 KCMIL
3
1
1600/24
2
3
1
2
3
1
2
3 777.7 KCMIL
1
1925/24
2
3

***
MM2

Tongue
Width

5/8

1.74

1/2

1.84

5/8

1.84

300
5/16

1.84

3/8

1.84

5/16

1.98

3/8

1.98

400
1/2

1.98

5/8

1.98

1/2

2.19

500

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

T
45

Stud
Hole
Size

5/8

90

T
L

Fig. 1

Fig. 2

Fig. 3

Conductor
Catalog Number
YA36L-TC58-FX
YA36L-TC58-FX-45
YA36L-TC58-FX-90
YA38L-TC12-FX
YA38L-TC12-FX-45
YA38L-TC12-FX-90
YA38L-TC58-FX
YA38L-TC58-FX-45
YA38L-TC58-FX-90
YA38L-TC516-FX
YA38L-TC516-FX-45
YA38L-TC516-FX-90
YA38L-TC38-FX
YA38L-TC38-FX-45
YA38L-TC38-FX-90
YA40L-TC516-FX
YA40L-TC516-FX-45
YA40L-TC516-FX-90
YA40L-TC38-FX
YA40L-TC38-FX-45
YA40L-TC38-FX-90
YA40L-TC12-FX
YA40L-TC12-FX-45
YA40L-TC12-FX-90
YA40L-TC58-FX
YA40L-TC58-FX-45
YA40L-TC58-FX-90
YA44L-TC12-FX
YA44L-TC12-FX-45
YA44L-TC12-FX-90
YA44L-TC58-FX
YA44L-TC58-FX-45
YA44L-TC58-FX-90

2.19

Figure
Dimensions
(B)
(T)
(L)
3.54
1.38 .27
3.51
2.11
3.41
1.45 .27
3.35
1.90
3.66
1.45 .27
3.60
2.15
3.03
1.45 .27
2.97
1.52
3.34
1.45 .27
3.29
1.83
3.05
1.42 .30
3.06
1.59
3.38
1.42 .30
3.38
1.91
3.43
1.42 .30
3.44
1.96
3.68
1.42 .30
3.69
2.21
3.79
1.65 .33
3.76
2.07
4.04
1.65 .33
4.01
2.32

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

U34RT (2)

Brown

20

U38XRT (2)

Pink

L99 1-7/16

U39RT (2)

Black

24 1-5/16

U44XRT (2)

Yellow L115 1-5/8

1-3/8

Y644M (1)

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

55

BURNDY
Telecommunications Products
ONE HOLE HYLUG
FLEX CONDUCTOR
STANDARD BARREL
BELLED END

DIE AND COLOR


CODE INFORMATION

BELLED END
ASSISTS FLEXIBLE
WIRE INSERTION

INSPECTION
WINDOW

ELECTRO-TIN
PLATED

TYPE YA-LB

CRIMPS
FLEXIBLE CONDUCTOR
ACCOMMODATION

COPPER COMPRESSION
TERMINAL
UL Listed 90 C,
600 Volts to 35 kV

CATALOG
NUMBER
YA8C-LB
YA5C-LB
YA4C-LB
YA3C-LB
YA2C-LB
YA1C-LB
YA25-LB
YA26-LB
YA27-LB
YA28-LB
YA29-LB
YA30-LB
YA31-LB
YA32-LB
YA34-LB
YA36-LB
YA38-LB

FLEXIBLE
CONDUCTOR
SIZE
AWG/KCMIL
8 AWG
6 AWG
5 AWG
4 AWG
3 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 kcmil
262.2 kcmil
300 kcmil
313.1 kcmil
350 kcmil
373.3 kcmil
400 kcmil
444.4 kcmil
450 kcmil
500 kcmil
535.3 kcmil
550 kcmil

YA39-LB

600 kcmil

YA40-LB

650 kcmil
750 kcmil
777.7 kcmil

YA44-LB

56

49

133

259
259
259
427
427
427
-

STRANDING CLASS (SIZE OF STRAND)


BATTERY WELDING
I
CABLE K CABLE M
H
(#24 STR.) (#30 STR.) (#34 STR.)
NUMBER OF STRANDS
41
168
420
63
266
665
84
336
836
133
105
420
1064
133
532
1323
161
665
1666
210
836
2107
266
1064
2646
259
342
1323
3325
418
1666
4256
427
532
2107
5320
637
2499
6384
427
735
2898
7851
3458
8806
427
980
1127
4522
11396
703
1372
5054
13664
703
1470
14945
703
-

LOCOMOTIVE
CABLE
37/24
61/24
91/24
105/24
125/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24

BOLT
SIZE
10
1/4
5/16
3/8

1/2

5/8

Dimensions
C
L
.41
1.12
.44
1.73
.50
1.92
.55
1.94
.61
1.97
.68
2.02
.75
2.26
.83
2.61
.91
2.67
1.02
2.77
1.11
2.82
1.20
2.93
1.29
3.31

DIE
INDEX
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025

WIRE
STRIP
LENGTH
7/16
7/8
5/16
1
1-1/16
1-1/8
1-3/16

1.40

3.56

1026

1-1/4

1.52

3.83

1027

1-7/16

1.69

4.31

1028

1-3/4

1.81

4.27

1029

1.89

4.27

1030

1.95

4.27

1031

2.17

4.5

1032

1-15/16

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
ONE HOLE HYLUG
FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED

DIE AND COLOR


CODE INFORMATION

BEVELED ENTRY

NO INSPECTION
WINDOW
CRIMPS

TYPE YAG-L-TC-LD
FLEXIBLE CONDUCTOR
ACCOMMODATION

LEAD PLATED

UL Listed 90 C,
600 Volts to 35 kV

B
T

90

45
L

Fig. 2

Fig. 3

Fig. 1

Conductor
Catalog Number
YAG18TC516LD
YAG8CLTC10LD
YAG8CLTC10LD45
YAG8CLTC10LD90
YAG8CLTC14LD
YAG8CLTC14LD45
YAG8CLTC14LD90
YAG8CLTC516LD
YAG8CLTC516LD45
YAG8CLTC516LD90
YAG8CLTC38LD
YAG8CLTC38LD45
YAG8CLTC38LD90
YAG8CLTC12LD
YAG8CLTC12LD45
YAG8CLTC12LD90
YAG6CLTC10LD
YAG6CLTC10LD45
YAG6CLTC10LD90
YAG6CLTC14LD
YAG6CLTC14LD45
YAG6CLTC14LD90
YAG6CLTC516LD
YAG6CLTC516LD45
YAG6CLTC516LD90
YAG6CLTC38LD
YAG6CLTC38LD45
YAG6CLTC38LD90
YAG6CLTC12LD
YAG6CLTC12LD45
YAG6CLTC12LD90

Fig #
AWG
1 22-18 AWG
1
2
3
1
2
3
37/24
1
2
#8 WELD
3
1
8 AWG
2
3
1
2
3
1
2
3
1
2
3
61/24
1
2
#6 WELD
3
1
#6 AWG
2
3
1
2
3

***
MM2

Stud
Hole Tongue
Size Width
5/16 .52
# 10

.41

1/4

.44

5/16

.52

3/8

.58

1/2

.71

# 10

.41

1/4

.48

5/16

.52

3/8

.58

1/2

.75

**
10

**
16

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


** The MM2 conductor size referenced here is for both Class
2 and Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

Figure
Dimensions
(B)
(T)
(L)
.25
.06
1.42
1.19
.44
.08
1.20
.74
1.32
.44
.08
1.31
.86
1.38
.44
.06
1.34
.92
1.51
.44
.06
1.45
1.04
1.76
.44
.05
1.67
1.28
1.30
.50
.08
1.26
.76
1.43
.50
.08
1.39
.88
1.49
.50
.07
1.44
.94
1.61
.50
.06
1.54
1.06
1.86
.50
.12
1.92
1.34

Dieless
(# of crimps)

MR20 (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

1/4

MY29-11 (1) W8CVT (1) W8CVT (1)


Y2MR (1) W8CRT (1) W8CRT (1)
Y1MR (1)
X8CRT (1) X8CRT (1)

U8CRT (1)

Red

49

7/16

Y1MR (1)
W5CVT (1) W5CVT (1)
MY29-11 (1)
W5CRT (1) W5CRT (1)
Y2MR (1)
X5CRT (1) X5CRT (1)
Y644M (1)

U5CRT (1)

Blue

1/2

See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

57

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
YAG4CLTC10LD
YAG4CLTC10LD45
YAG4CLTC10LD90
YAG4CLNT10LD
YAG4CLNT10LD45
YAG4CLNT10LD90
YAG4CLTC14LD
YAG4CLTC14LD45
YAG4CLTC14LD90
YAG4CLTC516LD
YAG4CLTC516LD45
YAG4CLTC516LD90
YAG4CLTC38LD
YAG4CLTC38LD45
YAG4CLTC38LD90
YAG4CLTC12LD
YAG4CLTC12LD45
YAG4CLTC12LD90
YAG2CLTC10LD
YAG2CLTC10LD45
YAG2CLTC10LD90
YAG2CLTC14LD
YAG2CLTC14LD45
YAG2CLTC14LD90
YAG2CLTC516LD
YAG2CLTC516LD45
YAG2CLTC516LD90
YAG2CLTC38LD
YAG2CLTC38LD45
YAG2CLTC38LD90
YAG2CLTC12LD
YAG2CLTC12LD45
YAG2CLTC12LD90
YAG1CLTC10LD
YAG1CLTC10LD45
YAG1CLTC10LD90
YAG1CLTC14LD
YAG1CLTC14LD45
YAG1CLTC14LD90
YAG1CLTC516LD
YAG1CLTC516LD45
YAG1CLTC516LD90
YAG1CLTC38LD
YAG1CLTC38LD45
YAG1CLTC38LD90
YAG1CLTC12LD
YAG1CLTC12LD45
YAG1CLTC12LD90

Fig #
AWG
1
2
3
1
2
3
1 91/24 - 105/24
2
#4 WELD
3
1
2
4 AWG
3
1
2
3
1
2
3
1
2
3
1
2
3
125/24
1
2
#2 WELD
3
2 AWG
1
2
3
1
2
3
1
2
3
1
2
3
225/24
1
2 175/24 - #1 WELD
3
1
1 AWG
2
3
1
2
3

45

Fig. 1

Stud
Hole
Size

Tongue
Width

# 10

.55

# 10

.41

1/4

.55

35

5/16

.55

3/8

.58

1/2

.71

#10

.68

1/4

.68

5/16

.68

3/8

.68

1/2

.77

# 10

.75

1/4

.83

5/16

.75

3/8

.75

1/2

.75

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

58

90

T
L

Conductor
***
MM2

B
T

Figure
Dimensions
(B)
(T)
(L)
1.36
.50
.09
1.33
.79
1.36
.50
.09
1.33
.79
1.48
.50
.09
1.46
.92
1.55
.50
.08
1.52
.98
1.67
.50
.08
1.63
1.10
1.92
.50
.07
1.84
1.34
1.52
.63
.10
1.47
.84
1.64
.63
.10
1.60
.97
1.70
.63
.10
1.66
1.03
1.83
.63
.10
1.78
1.15
2.12
.63
.10
2.03
1.40
1.61
.69
.12
1.57
.88
1.73
.69
.12
1.70
1.00
1.80
.69
.12
1.76
1.07
1.92
.69
.12
1.89
1.19
2.17
.69
.12
2.14
1.44

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

Y1MR (2)
W4CVT (1) W4CVT (1)
MY29-11 (1)
W4CRT (1) W4CRT (1)
Y2MR (2)
X4CRT (1) X4CRT (1)
Y644M (1)

U4CRT (1)

Gray

1/2

Y1MR (2)
W2CRT (1) W2CRT (1)
MY29-11 (1)
W2CVT (1) W2CVT (1)
Y2MR (2)
X2CRT (1) X2CRT (1)
Y644M (1)

U2CRT (1)

Brown

10

11/16

W1CVT (1) W1CVT (1)


MY29-11 (1)
W1CRT-1 (1) W1CRT-1 (1)
Y644M (1)
X1CRT-1 (1) X1CRT-1 (1)

U1CRT-1 (1)

Green

11

11/16

See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
YAG25LTC14LD
YAG25LTC14LD45
YAG25LTC14LD90
YAG25LTC516LD
YAG25LTC516LD45
YAG25LTC516LD90
YAG25LTC38LD
YAG25LTC38LD45
YAG25LTC38LD90
YAG25LTC12LD
YAG25LTC12LD45
YAG25LTC12LD90
YAG26LTC10LD
YAG26LTC10LD45
YAG26LTC10LD90
YAG26LTC14LD
YAG26LTC14LD45
YAG26LTC14LD90
YAG26LTC516LD
YAG26LTC516LD45
YAG26LTC516LD90
YAG26LTC38LD
YAG26LTC38LD45
YAG26LTC38LD90
YAG26LTC12LD
YAG26LTC12LD45
YAG26LTC12LD90
YAG26LTC58LD
YAG26LTC58LD45
YAG26LTC58LD90
YAG26LTC34LD
YAG26LTC34LD45
YAG26LTC34LD90
YAG27LTC10LD
YAG27LTC10LD45
YAG27LTC10LD90
YAG27LTC14LD
YAG27LTC14LD45
YAG27LTC14LD90
YAG27LTC516LD
YAG27LTC516LD45
YAG27LTC516LD90
YAG27LTC38LD
YAG27LTC38LD45
YAG27LTC38LD90
YAG27LTC12LD
YAG27LTC12LD45
YAG27LTC12LD90

Fig #
AWG
1
2
3
1
275/24
2
3
1/0 WELD
1
2
1/0 AWG
3
1
2
3
1
2
3
1
2
3
1
2
3
325/24
1
2 2/0 WELD
3
1
2/0 AWG
2
3
1
2
3
1
2
3
1
2
3
1
2
3
450/24
1
2 3/0 WELD
3
1
3/0 AWG
2
3
1
2
3

45

Fig. 1

Stud
Hole
Size

Tongue
Width

1/4

.83

5/16

.83

50

70

95

3/8

.83

1/2

.83

# 10

.93

1/4

.93

5/16

.93

3/8

.93

1/2

.93

5/8

.93

3/4

.93

#10

1.03

1/4

1.03

5/16

1.03

3/8

1.03

1/2

1.03

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

90

T
L

Conductor
***
MM2

B
T

Figure
Dimensions
(B)
(T)
(L)
1.77
.69
.12
1.73
1.03
1.84
.69
.12
1.79
1.09
1.96
.69
.12
1.92
1.22
2.21
.69
.12
2.17
1.47
1.82
.81
.13
1.75
.94
1.95
.81
.13
1.87
1.07
2.01
.81
.13
1.93
1.13
2.13
.81
.13
2.06
1.26
2.38
.81
.13
2.31
1.51
2.63
.81
.13
2.56
1.76
2.89
.81
.11
2.75
1.93
2.05
1.00 .14
1.93
.98
2.18
1.00 .14
2.06
1.10
2.24
1.00 .14
2.12
1.17
2.37
1.00 .14
2.24
1.29
2.62
1.00 .14
2.49
1.54

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W25RT (2) W25RT (2)


MY29-11 (1)
W25VT (2) W25VT (2)
Y644M (1)
X25RT (2) X25RT (2)

U25RT (1)

Pink

12

11/16

W26VT (2) W26VT (2)


MY29-11 (1)
W26RT (2) W26RT (2)
Y644M (1)
X26RT (2) X26RT (2)

U26RT (1)

Black

13

13/16

W27VT (2) W27VT (2)


X27RT (3) X27RT (3)
W27RT (2) W27RT (2)

U27RT (1)

Orange 14

MY29-11 (1)
Y644M (1)

1

See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

59

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
Fig #
YAG28LTC14LD
1
YAG28LTC14LD45
2
YAG28LTC14LD90
3
YAG28LTC516LD
1
YAG28LTC516LD45
2
YAG28LTC516LD90
3
YAG28LTC516N66LD 1
YAG28LTC38LD
1
YAG28LTC38LD45
2
YAG28LTC38LD90
3
YAG28LTC12LD
1
YAG28LTC12LD45
2
YAG28LTC12LD90
3
YAG28LTC58LD
1
YAG28LTC58LD45
2
YAG28LTC58LD90
3
YAG28LTC34LD
1
YAG28LTC34LD45
2
YAG28LTC34LD90
3
YAG29LTC14LD
1
YAG29LTC14LD45
2
YAG29LTC14LD90
3
YAG29LTC516LD
1
YAG29LTC516LD45
2
YAG29LTC516LD90
3
YAG29LTC38LD
1
YAG29LTC38LD45
2
YAG29LTC38LD90
3
YAG29LTC12LD
1
YAG29LTC12LD45
2
YAG29LTC12LD90
3
YAG29LTC58LD
1
YAG29LTC58LD45
2
YAG29LTC58LD90
3
YAG29LTC34LD
1
YAG29LTC34LD45
2
YAG29LTC34LD90
3
YAG30LTC516LD
1
YAG30LTC516LD45
2
YAG30LTC516LD90
3
YAG30LTC38LD
1
YAG30LTC38LD45
2
YAG30LTC38LD90
3
YAG30LTC12LD
1
YAG30LTC12LD45
2
YAG30LTC12LD90
3

AWG

45

Fig. 1

Stud
Hole
Size

Tongue
Width

1/4

1.14

5/16

1.14

3/8

1.14

550/24
**
4/0 WELD
120
4/0 AWG

550/24

1/2

1.14

5/8

1.14

3/4

1.14

1/4

1.14

5/16

1.14

3/8

1.14

4/0 WELD

1/2

1.14

5/8

1.14

3/4

1.14

5/16

1.20

3/8

1.20

1/2

1.20

250 FLEX
CLASS G - 259 STR.

CLASS H - 427 STR.

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


** The 120 MM2 referenced here is for both Class 2 and
Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

60

90

T
L

Conductor
***
MM2

B
T

Figure
Dimensions
(B)
(T)
(L)
2.26
1.03 .15
2.13
1.14
2.32
1.03 .15
2.19
1.21
2.64
2.45
1.03 .15
2.32
1.33
2.70
1.03 .15
2.57
1.58
2.95
1.03 .15
2.82
1.83
3.14
1.03 .15
3.00
2.02
2.26
1.03 .16
2.13
1.14
2.32
1.03 .16
2.19
1.21
2.45
1.03 .16
2.32
1.33
2.70
1.03 .16
2.57
1.58
2.95
1.03 .16
2.82
1.83
3.14
1.03 .16
3.00
2.02
2.34
1.03 .16
2.25
1.24
2.47
1.03 .16
2.37
1.36
2.72
1.03 .16
2.62
1.61

Dieless
(# of crimps)

MY29-11 (1)
Y644M (1)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W28VT (2) W28VT (2)


X28RT (3) X28RT (3)
W28RT (2) W28RT (2)

U28RT (1)

Purple 15 1-1/16

W29VT (2)
X29RT (4)

W29VT (2)
X29RT (4)
W29RT (2)

U29RT (1)

Yellow

16 1-1/16

W29VT (2)
X29RT (4)

W29VT (2)
X29RT (4)
W29RT (2)

U29RT (1)

Yellow

16 1-1/16

Y644M (1)

See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
YAG30LTC58LD
YAG30LTC58LD45
YAG30LTC58LD90
YAG30LTC34LD
YAG30LTC34LD45
YAG30LTC34LD90
YAG31LTC14LD
YAG31LTC14LD45
YAG31LTC14LD90
YAG31LTC516LD
YAG31LTC516LD45
YAG31LTC516LD90
YAG31LTC38LD
YAG31LTC38LD45
YAG31LTC38LD90
YAG31LTC12LD
YAG31LTC12LD45
YAG31LTC12LD90
YAG31LNT12LD
YAG31LNT12LD45
YAG31LNT12LD90
YAG31LTC58LD
YAG31LTC58LD45
YAG31LTC58LD90
YAG31LTC34LD
YAG31LTC34LD45
YAG31LTC34LD90
YAG32LTC38LD
YAG32LTC38LD45
YAG32LTC38LD90
YAG32LTC12LD
YAG32LTC12LD45
YAG32LTC12LD90
YAG32LTC58LD
YAG32LTC58LD45
YAG32LTC58LD90
YAG34LTC516LD
YAG34LTC516LD45
YAG34LTC516LD90
YAG34LTC516N66LD
YAG34LNT516N66LD
YAG34LTC38LD
YAG34LTC38LD45
YAG34LTC38LD90
YAG34LTC12LD
YAG34LTC12LD45
YAG34LTC12LD90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
2
3
1
2
3

AWG
250 FLEX
CLASS G - 259 STR.
CLASS H - 427 STR.

45

Fig. 1

Stud
Hole
Size

Tongue
Width

5/8

1.20

3/4

1.20

1/4

1.29

5/16

1.29

3/8

1.29

1/2

1.29

1/2

.96

5/8

1.29

637/259
250 FLEX

150

CLASS I, K, M

3/4

1.29

3/8

1.40

1/2

1.40

5/8

1.40

775/24-300 FLEX
185
313.1 kcmil

5/16
925/24-350 FLEX

1.55
.96

240
373.7 kcmil

3/8

1.55

1/2

1.73

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

90

T
L

Conductor
***
MM2

B
T

Figure
Dimensions
(B)
(T)
(L)
2.97
1.03 .16
2.87
1.86
3.16
1.03 .16
3.06
2.05
2.35
1.06 .18
2.26
1.19
2.41
1.06 .18
2.32
1.27
2.53
1.06 .18
2.45
1.40
2.78
1.06 .18
2.70
1.65
2.78
1.06 .18
2.70
1.65
3.03
1.06 .18
2.95
1.90
3.22
1.06 .18
3.13
2.09
2.72
1.19 .19
2.61
1.45
2.97
1.19 .19
2.86
1.70
3.22
1.19 .19
3.11
1.95
2.78
2.71
1.27 .23
1.41
3.09
1.27 .23
3.09
2.91
1.27 .23
2.83
1.53
3.16
1.27 .23
3.08
1.78

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W29VT (2)
X29RT (4)

W29VT (2)
X29RT (4)
W29RT (2)

U29RT (1)

Yellow

16 1-1/16

W30VT (2)

W30VT (2)
W30RT (2)

U30RT (2)

White

17

1-1/8

W31VT (2)

W31VT (2)
W31RT (2)

U31RT (2)

Red

18

1-1/4

W32VT (2)

W32VT (2)
W32RT (2)

U32RT (2)

Blue

19 1-5/16

Y644M (1)

See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

61

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG
925/24-350 FLEX
373.7 kcmil

45

***
MM2

Tongue
Width

5/8

1.73

1/2

1.73

444.4 kcmil

1325/24
500 FLEX

5/8

1.73

5/16

1.84

3/8

1.84

300

535.3 kcmil

1600/24-646 kcmil

1/2

1.84

5/8

1.84

5/16

1.96

3/8

1.96

400
650 FLEX

1925/24
750 FLEX
777.7 kcmil

1/2

1.96

5/8

1.96

1/2

2.18

500
5/8

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

62

Fig. 1

Stud
Hole
Size

1100/24-450 FLEX

90

Conductor
Catalog Number
YAG34LTC58LD
YAG34LTC58LD45
YAG34LTC58LD90
YAG36LTC12LD
YAG36LTC12LD45
YAG36LTC12LD90
YAG36LTC58LD
YAG36LTC58LD45
YAG36LTC58LD90
YAG38LTC516LD
YAG38LTC516LD45
YAG38LTC516LD90
YAG38LTC38LD
YAG38LTC38LD45
YAG38LTC38LD90
YAG38LTC12LD
YAG38LTC12LD45
YAG38LTC12LD90
YAG38LTC58LD
YAG38LTC58LD45
YAG38LTC58LD90
YAG40LTC516LD
YAG40LTC516LD45
YAG40LTC516LD90
YAG40LTC38LD
YAG40LTC38LD45
YAG40LTC38LD90
YAG40LTC12LD
YAG40LTC12LD45
YAG40LTC12LD90
YAG40LTC58LD
YAG40LTC58LD45
YAG40LTC58LD90
YAG44LTC12LD
YAG44LTC12LD45
YAG44LTC12LD90
YAG44LTC58LD
YAG44LTC58LD45
YAG44LTC58LD90

B
T

2.18

Figure
Dimensions
(B)
(T)
(L)
3.41
1.27 .23
3.33
2.03
3.34
1.38 .27
3.30
1.86
3.59
1.38 .27
3.55
2.11
3.08
1.45 .27
3.01
1.52
3.39
1.45 .27
3.32
1.83
3.46
1.45 .27
3.38
1.90
3.71
1.45 .27
3.63
2.15
3.11
1.42 .30
3.10
1.59
3.42
1.42 .30
3.42
1.91
3.48
1.42 .30
3.47
1.96
3.73
1.42 .30
3.72
2.21
3.85
1.65 .33
3.81
2.07
4.10
1.65 .33
4.06
2.32

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W32VT (2)

W32VT (2)
W32RT (2)

U32RT (2)

U34RT (2)

U38XRT (2)

Pink

L99 1-7/16

U39RT (2)

Black

24

U44XRT (2)

Yellow L115 1-5/8

Blue

19

1-5/16

Brown 20

1-3/8

Y644M (1)

1-5/16

See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
ONE HOLE HYLUG
FLEX CONDUCTOR
LONG BARREL
BELLED END

DIE AND COLOR


CODE INFORMATION

BELLED END
ASSISTS FLEXIBLE
WIRE INSERTION

NO INSPECTION
WINDOW

TYPES YA-TC-FXB,
YAV-TC-FXB

CRIMPS
ELECTRO-TIN
PLATED

FLEXIBLE CONDUCTOR
ACCOMMODATION

UL Listed 90 C,
600 Volts to 35 kV
B
T
L

Conductor

**

Stud
Hole
Size
8-10

10

1/4

***
MM2

Tongue
Width

Catalog Number
YA8C-TC10-FXB

AWG
37/24 #8 WELD

YA8C-TC14-FXB

YAV6C-TC14-FXB

8 AWG
61/24 #6 WELD
#6 AWG
91/24 #5 STR

**
16

1/4

YAV5C-TC14-FXB

#5 AWG

1/4

.44

YAV4C-TC10-FXB
YAV4C-TC14-FXB
YAV4C-TC516-FXB

91/24 105/24
#4 WELD
#4 AWG
125/24 150/24

8-10
1/4
5/16
8-10

.55
.55
.63

YAV6C-TC10-FXB

YAV2C-TC10-FXB

.41
8-10

35
YAV2C-TC516-FXB
YAV1C-TC10-FXB
YAV1C-TC516-FXB
YAV25-TC10-FXB
YAV25-TC516-FXB
YAV25-TC38-FXB
YAV25-TC12-FXB

#2 WELD #2 AWG
175/24 225/24
#1 WELD #1AWG

275/24
1/0 WELD
1/0 AWG

50

70

YAV26-TC12-FXB

352/24 2/0 WELD


2/0 AWG
450/24 3/0 WELD

YAV27-TC12-FXB

3/0 AWG

YAV28-TC38-FXB

550/24 4/0 WELD


4/0 AWG
250 FLEX
Class G 259 str.
Class H 427 str.
250 FLEX
637/24
Class I,K,M

YAV26-TC38-FXB

YAV28-TC12-FXB
YA30-TC12-FXB
YA31-TC12-FXB

.
48

.67
5/16
8-10
5/16
8-10
5/16
3/8
1/2

.69

.83

Figure
Dimensions
Dieless
(B)
(T)
(L)
(# of crimps)
1.64 MRC840 (2)
.90
.08
MY29-11 (2)
1.76 Y2MR + Y1MR (2)
1.90 MY29-11 (2)
1.22 .08
Y2MR + Y1MR (2)
2.11 Y644M (1)
MY29-11 (2)
1.22 .07
2.11 Y2MR + Y1MR (2)
Y644M (1)
1.22 .09
2.03 MY29-11 (2)
1.22 .09
2.16 Y2MR + Y1MR (4)
1.22 .09
2.22 Y644M (1)
2.23 MY29-11 (2)
1.35 .10
Y2MR + Y1MR (4)
2.42 Y644M (1)
2.40 MY29-11 (2)
1.50 .12
2.59 Y644M (1)
2.44
2.63 MY29-11 (2)
1.50 .12
2.75 Y644M (1)
3.19

.93

1.63

95

1/2

1.10

1.64

.14

**

3/8
1.12

1.77

.14

Wire
Color Die Strip
Code Index Length

W8CVT (2) W8CVT (2)

U8CRT (2)

Red

49

1

W5CVT (2) W5CVT (2)

U5CRT (2)

Blue

1-5/16

W5CVT (2) W5CVT (2)

U5CRT (2)

Blue

1-5/16

W4CVT (2) W4CVT (2)

U4CRT (2)

Gray

1-5/16

W2CVT (2) W2CVT (2)

U2CRT (2)

Brown

10 1-7/16

W1CVT (2) W1CVT (2)

U1CRT-1 (2)

Green

11 1-9/16

W25VT (4)

W25VT (4)

U25RT (2)

Pink

12 1-9/16

MY29-11 (2)
Y644M (1)

W26VT (4)

W26VT (4)

U26RT (2)

Black

13 1-13/16

MY29-11 (2)
Y644M (1)

W27VT (4)

W27VT (4)

U27RT (2)

Orange

14

1-13/16

MY29-11 (2)
Y644M (1)

W28VT (4)

W28VT (4)

U28RT (2)

Purple

15

1-7/8

3.61

2.94
3/8
1/2

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750
MD7-34R
Y500CTHS
Y46*, PAT750

.13
3.37
3.43
3.17

120

1/2

1/2

1.20

2.16

.16

4.02

Y644M (1)

W29VT (4)

W29VT (4)

U29RT (2)

Yellow

16

2-1/4

150

1/2

1.28

2.18

.18

4.08

Y644M (1)

W30VT (4)

W30VT (4)

U30RT (4)

White 17

2-1/4

* Use PUADP-1 adapter with U dies in Y46 HYPRESS


** The MM2 conductor sizes referenced here are for both
Class 2 and Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

P44RT for use with Y46 HYPRESS only.


PUADP-1 adapter not required.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.

For CUSTOMER SERVICE call 1-800-346-4175

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

63

BURNDY
Telecommunications Products
ONE HOLE HYLUG
FLEX CONDUCTOR
LONG BARREL
BELLED END
(Continued)

B
T
L

Conductor
Catalog Number
YA32-TC12-FXB
YA32-TC58-FXB
YA34-TC12-FXB
YA34-TC58-FXB
YA36-TC12-FXB
YA36-TC58-FXB
YA38-TC58-FXB
YA40-TC58-FXB
YA44-TC58-FXB
YA46-TC58-FXB

AWG

***
MM2

313.1 kcmil

185

373.7 kcmil
925/24
444.4 kcmil
1100/24
535.3 kcmil
1325/24
646 kcmil - 1600/24
777.7 kcmil - 1925/24
1111 kcmil

240

300
400
500

Stud
Hole
Size
1/2
5/8
1/2
5/8
1/2
5/8
5/8
5/8
5/8
5/8

* Use PUADP-1 adapter with U dies in Y46 HYPRESS


** The 16 MM2 and 120 MM2 referenced here are for both
Class 2 and Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.
P45RT for use with Y46 HYPRESS only.
PUADP-1 adapter not required.

64

Tongue
Width
1.38
1.50
1.69
1.81
1.95
2.17
2.69

Figure
Dimensions
(B)
(T)
(L)
4.28
2.32 .19
4.34
4.54
2.48 .23
4.60
5.09
2.95 .26
5.15
3.08 .27
5.32
3.24 .30
5.53
3.33 .33
5.71
3.58 .39
6.19

Dieless
(# of crimps)

Y644M (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W31VT (4)

W31VT (4)

U31RT (4)

Red

18

W32VT (4)

W32VT (4)

U32RT (4)

Blue

19 2-9/16

U34RT (4)

Brown

20 3-1/16

U38XRT (4)
U39RT (4)
U44XRT (4)
**P45RT (4)

Pink L99 3-3/16


Black 24 3-5/16
Yellow L115 3-7/16
Yellow 29 3-11/16

2-1/4

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
ONE HOLE HYLUG
FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW

BEVELED
ENTRY

DIE AND COLOR


CODE INFORMATION
INSPECTION
WINDOW

TYPES YAZ, YAZV

CRIMP
ELECTRO-TIN
PLATED

COPPER COMPRESSION
TERMINAL

CABLE
ACCOMMODATION

UL Listed 90 C,
600 Volts to 35 kV
B
90

B
T

T
L

Fig. 1
Conductor
AWG

***
MM2

Stud
Hole
Size

Tongue
Width

# 10

.41

1/4

.44

3/8

.58

1/4

.48

Figure
Dimensions
(B)
(T)
(L)
1.58
.75
.08
1.47
.75
1.7
.75
.08
1.58
.87
1.89
.75
.06
1.72
1.05
2.03
.75
.08
1.83
.89
2.22
.75
.06
1.97
1.06
2.21
1.25 .09
1.97
.93
2.39
1.25 .08
2.13
1.11
2.39
1.38 .10
2.13
.98
2.57
1.38 .10
2.31
1.16
3.01
1.38 .09
2.75
1.6
2.42

Dieless

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1

YAZV1CTC14FX45

YAZV1CTC14FX90

1.02

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


** The MM2 conductor size referenced here is for both Class
2 and Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.

37/24
#8 WELD
#8 AWG

61/24
#6 WELD
#6 AWG

91/24
105/24
#4 WELD
#4 AWG

125/24
150/24
#2 WELD
#2 AWG

175/24

**
10

**
16
3/8

.58

1/4

.55

35

3/8

.58

1/4

.68

3/8

.68

1/2

.83

1/4

.75

For CUSTOMER SERVICE call 1-800-346-4175

1.38

.12

2.19

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Catalog Number
YAZ8C-TC10
YAZ8C-TC10-45
YAZ8C-TC10-90
YAZ8C-TC14
YAZ8C-TC14-45
YAZ8C-TC14-90
YAZ8C-TC38
YAZ8C-TC38-45
YAZ8C-TC38-90
YAZV6CTC14FX
YAZV6CTC14FX45
YAZV6CTC14FX90
YAZV6CTC38FX
YAZV6CTC38FX45
YAZV6CTC38FX90
YAZV4CTC14FX
YAZV4CTC14FX45
YAZV4CTC14FX90
YAZV4CTC38FX
YAZV4CTC38FX45
YAZV4CTC38FX90
YAZV2CTC14FX
YAZV2CTC14FX45
YAZV2CTC14FX90
YAZV2CTC38FX
YAZV2CTC38FX45
YAZV2CTC38FX90
YAZV2CTC12FX
YAZV2CTC12FX45
YAZV2CTC12FX90
YAZV1CTC14FX

(# of crimps)

45

Wire
Color Die Strip
Code Index Length

Y1MR (2)
Y8MRB-1 (2)
W8CVT (2) W8CVT (2)
Y2MR (2)
W8CRT (2) W8CRT (2)
MY29-3 (2)
X8CRT (2) X8CRT (2)
MY29-11 (2)
MRC840 (2)

U8CRT (2)

Red

49

7/16

Y1MR(2)
Y2MR (2)
W5CVT (2) W5CVT (2)
MY29-3 (2)
W5CRT (2) W5CRT (2)
MY29-11 (2)
X5CRT (2) X5CRT (2)
MRC840 (2)
Y644M (1)

U5CRT (2)

Blue

1-3/16

W4CVT (2) W4CVT (2)


W4CRT (2) W4CRT (2)
X4CRT (2) X4CRT (2)

U4CRT (2)

Gray

1-5/16

U2CRT (2)

Brown

10 1-7/16

U1CRT-1 (2)

Green

11

Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
W2CVT (2) W2CVT (2)
Y644M (1)
W2CRT (2) W2CRT (2)
X2CRT (2) X2CRT (2)

MY29-3 (2) W1CRT-1 (2) W1CRT-1 (2)


MY29-11 (2)
MRC840 (2) W1CVT (2) W1CVT (2)
Y644M (1) X1CRT-1 (2) X1CRT-1 (2)

11/16

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

65

BURNDY
Telecommunications Products
B

ONE HOLE HYLUG


FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)

Catalog Number
YAZV1CTC516FX
YAZV1CTC516FX45
YAZV1CTC516FX90
YAZV1CTC38FX
YAZV1CTC38FX45
YAZV1CTC38FX90
YAZV25TC14FX
YAZV25TC14FX45
YAZV25TC14FX90
YAZV25TC38FX
YAZV25TC38FX45
YAZV25TC38FX90
YAZV25TC12FX
YAZV25TC12FX45
YAZV25TC12FX90
YAZV26TC14FX
YAZV26TC14FX45
YAZV26TC14FX90
YAZV26TC38FX
YAZV26TC38FX45
YAZV26TC38FX90
YAZV26TC12FX
YAZV26TC12FX45
YAZV26TC12FX90
YAZV27TC38FX
YAZV27TC38FX45
YAZV27TC38FX90
YAZV28NT38FX
YAZV28NT38FX-45
YAZV28NT38FX-90
YAZV28TC38FX
YAZV28TC38FX45
YAZV28TC38FX90
YAZV28TC12FX
YAZV28TC12FX45
YAZV28TC12FX90
YAZV29NT516FX
YAZV29NT516FX-45
YAZV29NT516FX-90
YAZ30TC38FX
YAZ30TC38FX-45
YAZ30TC38FX-90
YAZ31TC38FX
YAZ31TC38FX45
YAZ31TC38FX90
YAZ32TC38FX
YAZ32TC38FX45
YAZ32TC38FX90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG
225/24
#1 WELD
#1 AWG

275/24
1/0 WELD
1/0 AWG

325/24
2/0 WELD
2/0 AWG

450/24
3/0 WELD
3/0 AWG

550/24
4/0 WELD
4/0 AWG

550/24
4/0 WELD
250 FLEX
CLASS G 259 STR.
CLASS H 427 STR.
262.2 FLEX
637/24
CLASS I, K, M
775/24
313.1 kcmil
300 FLEX

Stud
Hole
Size

Tongue
Width

5/16

.75

3/8

.75

1/4

.83

3/8

.83

1/2

.83

1/4

.93

3/8

.93

1/2

.93

3/8

1.03

3/8

.94

3/8

1.14

1/2

1.14

5/16

.96

3/8

1.20

150

3/8

1.28

185

3/8

1.55

50

70

95

**
120

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS


** The 120 MM2 referenced here is for both Class 2 and
Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

66

Figure
Dimensions
(B)
(T)
(L)
2.47
1.38 .12
2.24
1.08
2.60
1.38 .12
2.37
1.20
2.58
1.50 .12
2.30
1.04
2.76
1.50 .12
2.48
1.23
3.20
1.50 .12
2.92
1.66
2.58
1.50 .13
2.30
1.04
2.76
1.50 .13
2.48
1.23
3.20
1.50: .13
2.92
1.66
2.80
1.50 .14
2.52
1.25
2.96
1.62 .14
2.67
1.30
2.96
1.62 .14
2.67
1.30
3.18
1.62 .14
2.89
1.52
2.87
2.00 .16
2.60
1.21
3.42
2.00 .16
3.05
1.37
3.45
2.00 .18
3.10
1.41
3.62
2.12 .19
3.25
1.46

45

Fig. 1

Fig. 2

Conductor
***
MM2

B
90

Dieless
(# of crimps)

T
L

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W1CRT-1 (2) W1CRT-1 (2)


W1CVT (2) W1CVT (2)
X1CRT-1 (2) X1CRT-1 (2)

U1CRT-1 (2)

Green

11 1-7/16

W25VT (4) W25VT (4)


W25RT (4) W25RT (4)
X25RT (4) X25RT (4)

U25RT (2)

Pink

12 1-9/16

W26VT (4) W26VT (4)


MY29-11 (2)
W26RT (4) W26RT (4)
Y644M (1)
X26RT (4) X26RT (4)

U26RT (2)

Black

13 1-9/16

W27RT (4) W27RT (4)


W27VT (4) W27VT (4)
X27RT (4) X27RT (4)

U27RT (2)

Orange 14 1-9/16

W28VT (4) W28VT (4)


W28RT (4) W28RT (4)
X28RT (6) X28RT (6)

U28RT (2)

Purple 15

U29RT (2)

Yellow

16 2-1/16

U29RT (2)

Yellow

16 2-1/16

W29VT (4)
X29RT (8)
W29VT (4)
X29RT (8)
Y644M (1)

W29RT (4)
W29VT (4)
X29RT (8)
W29RT (4)
W29VT (4)
X29RT (8)

1-11/16

W30VT (4)

W30VT (4)
W30RT (4)

U30RT (4)

White

17 2-1/16

W31VT (4)

W31VT (4)
W31RT (4)

U31RT (4)

Blue

19 2-3/16

See tooling section of this catalog for complete tool and


die listings. Use ONLY color-coded die recommendations
for -FX connectors. For nest/indentor system contact
factory.

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

ONE HOLE HYLUG


FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)

Catalog Number
YAZ34NT38FX
YAZ34NT38FX-45
YAZ34NT38FX-90
YAZ34TC38FX
YAZ34TC38FX45
YAZ34TC38FX90
YAZ34TC12FX
YAZ34TC12FX45
YAZ34TC12FX90
YAZ36TC38FX
YAZ36TC38FX45
YAZ36TC38FX90
YAZ38NT38FX
YAZ38NT38FX-45
YAZ38NT38FX-90
YAZ38TC38FX
YAZ38TC38FX45
YAZ38TC38FX90
YAZ38NT12FX
YAZ38NT12FX-45
YAZ38NT12FX-90
YAZ38TC12FX
YAZ38TC12FX45
YAZ38TC12FX90

Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

925/24
373.3 kcmil
350 FLEX

1100/24
444.4 kcmil
450 FLEX

1325/24
535.3 kcmil
500 FLEX

240

Stud
Hole
Size

Tongue
Width

3/8

.96

3/8

1.52

1/2

1.52

3/8

1.72

3/8

1.63

3/8

1.81

300
1/2

1.63

1/2

1.81

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


Catalog # PUADP-1 adapter is required to use U dies in
Y46 series tools.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

Figure
Dimensions
(B)
(T)
(L)
3.85
2.25 .23
3.5
1.54
3.85
2.25 .23
3.5
1.54
4.29
2.25 .23
3.94
1.98
4.55
2.69 .26
4.14
1.81
4.72
2.81 .27
4.26
1.84
4.72
2.81 .27
4.26
1.84
4.97
2.81 .27
4.51
2.09
4.97
2.81 .27
4.51
2.09

45

Fig. 1

Fig. 2

Conductor
***
MM2

B
90

Dieless
(# of crimps)

T
L

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W32VT (4)

W32VT (4)
W32RT (4)

U32RT (4)

Blue

19 2-5/16

U34RT (4)

Brown

20

U38XRT (4)

Pink

L99 2-7/8

2-3/4

Y644M (1)

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

67

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
STANDARD BARREL

DIE AND COLOR


CODE INFORMATION

BEVELED
ENTRY

INSPECTION
WINDOW

TYPES YAV-2TC, YA-L2L,


YA-2LN, AND YA-L-2TC

CRIMP

COPPER COMPRESSION
TERMINAL

CABLE
ACCOMMODATION

ELECTRO-TIN
PLATED

UL Listed 90 C,
600 Volts to 35 kV
B

B
T

Fig. 1

Conductor
Catalog Number
YAV102TC10
YAV102TC10-45
YAV102TC10-90
YAV102TC14
YAV102TC14-45
YAV102TC14-90
YAV102TC14E1
YAV102TC14E2
YAV102TC38
YAV102TC38-45
YAV102TC38-90
YA8CL-2TC10
YA8CL-2TC10-45
YA8CL-2TC10-90
YA8CL-2TC10E2
YA8CL-2TC10E2-45
YA8CL-2TC10E2-90
YA8CL-2TC14
YA8CL-2TC14-45
YA8CL-2TC14-90
YA8CL-2TC14E1
YA8CL-2TC14E1-45
YA8CL-2TC14E1-90
YA8CL-2TC14E2
YA8CL-2TC14E2-45
YA8CL-2TC14E2-90
YA8CL-2TC38
YA8CL-2TC38-45
YA8CL-2TC38-90
YA8C-2LN
YA8C-2LN-45
YA8C-2LN-90

Fig
#
AWG
1
2
3
1
2 #14-10 STR
3
1 #12-10 SOL
1
1
2
3
1
2
3
1
2
3
1
2 #8 AWG
3
1 #8 WELD
2
3
37/24
1
2
#6 SOL
3
1
2
3
1
2
3

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
# 10

5/8

.38

1/4

5/8

.47

1/4
1/4

1
3/4

.47
.47

3/8

1

.56

# 10

5/8

.41

# 10

3/4

.41

1/4

5/8

.41

1/4

1

.41

1/4

3/4

.41

3/8

1

.57

10

1/2 1-3/4 0.83

-- Color code not assigned.


* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

68

Figure
Dimensions
(B) (T)
(L)
1.72
.38 .06 1.70
1.33
1.84
.38 .06 1.81
1.45
.38 .05 2.22
.38 .05 1.97
2.40
.38 .04 2.34
2.01
1.83
.44 .08 1.83
1.37
1.95
.44 .08 1.96
1.50
1.95
.44 .08 1.94
1.49
2.33
.44 .08 2.32
1.87
2.08
.44 .08 2.07
1.62
2.52
.44 .06 2.46
2.05
3.75
.44 .12 3.83
3.27

Fig. 3

Fig. 2

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Y8MRB-1 (1)

Y1MR (1)
Y2MR (1)
W8CVT (1) W8CVT (1)
Y8MRB-1 (1)
W8CRT (1) W8CRT (1)
MY29-3 (1)
X8CRT (1) X8CRT (1)
MY29-11 (1)
MRC840 (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
The MM2 conductor size referenced here is for both Class
2 and Class 5.

Wire
Color Die Strip
Code Index Length

--

7/16

U8CRT (1)

Red

49

1/2

See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 volts consult cable manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
B

TWO HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Fig. 1

Conductor
Fig
Catalog Number
#
YA6C-2L
1
YA6C-2L-45
2
YA6C-2L-90
3
YA6C-2LN
1
YA6C-2LN-45
2
YA6C-2LN-90
3
YA6CL-2TC10
1
YA6CL-2TC10-45
2
YA6CL-2TC10-90
3
YA6CL-2TC14
1
YA6CL-2TC14-45
2
YA6CL-2TC14-90
3
YA6CL-2TC14E
1
YA6CL-2TC14E-45
2
YA6CL-2TC14E-90
3
YA6CL-2TC14E1
1
YA6CL-2TC14E1-45
2
YA6CL-2TC14E1-90
3
YA6CL-2TC14E2
1
YA6CL-2TC14E2-45
2
YA6CL-2TC14E2-90
3
YA6CL-2TC38
1
YA6CL-2TC38-45
2
YA6CL-2TC38-90
3
YA6C-2L51
1
YA6C-2L51-45
2
YA6C-2L51-90
3
YA6CL-2TC516
1
YA6CL-2TC516-45
2
YA6CL-2TC516-90
3
YA6CL-2TC516E2
1
YA6CL-2TC516E2-45 2
YA6CL-2TC516E2-90 3
YA6C-2L52
1
YA6C-2L52-45
2
YA6C-2L52-90
3
YA5C-2L
1
YA5C-2L-45
2
YA5C-2L-90
3
YA4C-2L
1
YA4C-2L-45
2
YA4C-2L-90
3
YA4CL-2TC14
1
YA4CL-2TC14-45
2
YA4CL-2TC14-90
3
YA4CL-2TC38
1
YA4CL-2TC38-45
2
YA4CL-2TC38-90
3
YA4CL-2TC14E1
1
YA4CL-2TC14E1-45
2
YA4CL-2TC14E1-90
3

AWG

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

6 AWG

5 AWG

4 AWG

5/8

.45

1/2 1-3/4

.81

# 10

5/8

.42

1/4

5/8

.45

1/4

1/2

.45

1/4

1

.45

1/4

3/4

.44

3/8

1

.63

# 10

1/2

.42

5/16

1

.52

5/16

3/4

.52

1/4

1/2

.45

1/4

5/8

.44

1/4

5/8

.49

1/4

5/8

.49

3/8

1

.58

1/4

1

.49

-- Color code not assigned.


See tooling section of this catalog for complete tool and
die listings.

B
T

Figure
Dimensions
(B) (T)
(L)
2.01
.08 1.98
1.45
3.87
.12 3.91
3.28
1.94
.09 1.94
1.39
2.07
.08 2.04
1.51
1.94
.08 1.91
1.38
2.44
.08 2.41
1.88
.54
2.19
.08 2.16
1.63
2.63
.06 2.56
2.06
1.79
.09 1.78
1.23
2.51
.07 2.45
1.94
2.26
.07 2.20
1.69
1.88
.08 1.85
1.32
2.28
.81 .07 2.15
1.44
2.30
.81 .09 2.21
1.48
2.36
.81 .09 2.27
1.54
2.96
.81 .08 2.82
2.09
2.74
.81 .09 2.65
1.91

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

Y1MR (1)
W5CVT (1) W5CVT (1)
Y2MR (1)
W5CRT (1) W5CRT (1)
MY29-3 (1)
X5CRT (1) X5CRT (1)
MY29-11 (1)
X8CART (1) X8CART (1)
MRC840 (1)

U5CRT (1)
U8CABT (1)

Blue

7/8

Y1MR (2)
Y2MR (2)
W4CVT (1) W4CVT (1)
MY29-3 (1)
W4CRT (1) W4CRT (1)
MY29-11 (1)
X4CRT (1) X4CRT (1)
MRC840 (1)
Y644M (1)

U4CRT (1)
U6CABT (1)

Gray

7/8

For applications greater than 2000 volts consult cable


manufacturer for voltage stress relief instructions.
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.

For CUSTOMER SERVICE call 1-800-346-4175

** P-RT die sets for use in Y46 HYPRESS only, PUADP-1


adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

69

BURNDY
Telecommunications Products
B

TWO HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Fig. 1

Conductor
Catalog Number
YA4C-2LN
YA4C-2LN-45
YA4C-2LN-90
YA4CL-2TC14E2
YA4CL-2TC14E2-45
YA4CL-2TC14E2-90
YA4CL-2TC516
YA4CL-2TC516-45
YA4CL-2TC516-90
YA3CL-2TC14
YA3CL-2TC14-45
YA3CL-2TC14-90
YA3C-2L
YA3C-2L-45
YA3C-2L-90
YA3CL-2TC38
YA3CL-2TC38-45
YA3CL-2TC38-90
YA2C-2L
YA2C-2L-45
YA2C-2L-90
YA2C-2LN
YA2C-2LN-45
YA2C-2LN-90
YA2CL-2TC14
YA2CL-2TC14-45
YA2CL-2TC14-90
YA2CL-2TC14E1
YA2CL-2TC14E1-45
YA2CL-2TC14E1-90
YA2CL-2TC14E2
YA2CL-2TC14E2-45
YA2CL-2TC14E2-90
YA2CL-2TC38
YA2CL-2TC38-45
YA2CL-2TC38-90
YA2CL-2TC516
YA2CL-2TC516-45
YA2CL-2TC516-90
YA1C-2LN
YA1C-2LN-45
YA1C-2LN-90
YA1C-2L
YA1C-2L-45
YA1C-2L-90
YA1CL-2TC14
YA1CL-2TC14-45
YA1CL-2TC14-90
YA1CL-2TC14E2
YA1CL-2TC14E2-45
YA1CL-2TC14E2-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

4 AWG

3 AWG

2 AWG

1 AWG

***
MM2

25

35

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2 1-3/4

.83

1/4

3/4

.49

5/16

1

.52

1/4

5/8

.55

5/16

5/8

.55

3/8

1

.58

5/16

3/4

.60

1/2 1-3/4

.83

1/4

5/8

.60

1/4

1

.60

1/4

3/4

.60

3/8

1

.60

5/16

1

.60

1/2 1-3/4

.81

5/16

.68

70

7/8

50
1/4

5/8

.68

1/4

3/4

.68

-- Color code not assigned.


See tooling section of this catalog for complete tool and
die listings.

B
T

Figure
Dimensions
(B) (T)
(L)
4.14
.81 .12 4.10
3.30
2.49
.81 .09 2.40
1.66
2.80
.81 .09 2.69
1.97
2.45
.81 .09 2.33
1.55
2.64
.88 .09 2.52
1.74
3.06
.88 .08 2.90
2.11
2.67
.88 .11 2.57
1.77
4.27
.88 .11 4.19
3.14
2.47
.88 .11 2.38
1.58
2.85
.88 .11 2.77
1.96
2.60
.88 .11 2.51
1.71
3.03
.88 .11 2.94
2.15
2.91
.88 .11 2.82
2.02
4.32
.88 .12 4.23
3.36
2.82
.88 .10 2.71
1.92
2.51
.88 .10 2.40
1.60
2.64
.88 .10 2.52
1.73

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W4CVT (1) X4CRT (1)

U4CRT (1)

Gray

7/8

W3CRT (1) W3CRT (1)

U3CRT (1)

White

15/16

W2CVT (1) W2CVT (1)


W2CRT (1) W2CRT (1)
X2CRT (1) X2CRT (1)

U2CRT (1)

Brown

10

15/16

U1CRT-1 (1)
U4CABT (1)

Green

11

15/16

Y1MR (2)
Y2MR (2)
MY29-3 (1)
MY29-11 (1)
MRC840 (1)
Y644M (1)

Y1MR (2)
MY29-3 (1) W1CVT (1) W1CVT (1)
MY29-11 (1) W1CRT-1 (1) W1CRT-1 (1)
MRC840 (1) X1CRT-1 (1) X1CRT-1 (1)
Y644M (1)

For applications greater than 2000 volts consult cable


manufacturer for voltage stress relief instructions.
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.

** P-RT die sets for use in Y46 HYPRESS only, PUADP-1


adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
B

TWO HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Fig. 1

Conductor
Catalog Number

Fig
#

YA1CL-2TC38

YA1CL-2TC38-45

YA1CL-2TC38-90
YA25-2L
YA25-2L-45
YA25-2L-90
YA252LN
YA252LN-45
YA252LN-90
YA25L-2TC14
YA25L-2TC14-45
YA25L-2TC14-90
YA25L-2TC14E1
YA25L-2TC14E1-45
YA25L-2TC14E1-90
YA25L-2TC14E2
YA25L-2TC14E2-45
YA25L-2TC14E2-90
YA25L-2TC38
YA25L-2TC38-45
YA25L-2TC38-90
YA26-2L
YA26-2L-45
YA26-2L-90
YA262LN
YA262LN-45
YA262LN-90
YA26L-2TC14
YA26L-2TC14-45
YA26L-2TC14-90
YA26L-2TC14E1
YA26L-2TC14E1-45
YA26L-2TC14E1-90
YA26L-2TC14E2
YA26L-2TC14E2-45
YA26L-2TC14E2-90
YA26L-2TC38
YA26L-2TC38-45
YA26L-2TC38-90
YA272LN
YA272LN-45
YA272LN-90
YA27L-2TC14E2
YA27L-2TC14E2-45
YA27L-2TC14E2-90
YA27L-2TC38
YA27L-2TC38-45
YA27L-2TC38-90

3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width

Figure
Dimensions
(B) (T)
(L)
3.07

3/8

5/16

1/0 AWG

2/0 AWG

3/0 AWG

.68

7/8

.88 .10 2.96

.75

.88 .12

1/2 1-3/4

.83

.88 .11

1/4

5/8

.75

.88 .12

1/4

.75

.88 .12

1/4

3/4

.75

.88 .12

3/8

.75

.88 .12

5/16

7/8

.83

.94 .12

1/2 1-3/4

.83

.94 .12

1/4

.83

.94 .12

5/8

70

1/4

.83

.94 .12

1/4

3/4

.83

.94 .12

3/8

.83

.94 .12

1/2 1-3/4

.91

1.00 .13

1/4

3/4

.91

1.00 .12

3/8

.91

1.00 .12

-- Color code not assigned.


See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 volts consult cable manufacturer for voltage stress relief instructions.

B
T

2.17
2.85
2.77
1.95
4.29
4.20
3.38
2.64
2.45
1.58
3.01
2.91
1.95
2.66
2.58
1.70
3.10
3.02
2.14
2.95
2.84
1.98
4.39
4.27
3.41
2.64
2.52
1.66
3.01
2.90
2.04
2.76
2.65
1.79
3.20
3.09
2.22
4.48
4.35
3.44
2.86
2.73
1.81
3.30
3.17
2.25

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

MY29-3 (1)
MY29-11 (1)
W1CVT (1) X1CRT-1 (1)
MRC840 (1)
Y644M (1)

U1CRT (1)

W25VT (2) W25VT (2)


W25RT (2) W25RT (2)
X25RT (2) X25RT (2)

U25RT (1)
U2CABT (1)

Pink

12

15/16

W26VT (2) W26VT (2)


W26RT (2) W26RT (2)
X26RT (2) X26RT (2)

U26RT (1)

Black

13

1

W27VT (2) W27VT (2)


W27RT (2) W27RT (2)
X27RT (3) X27RT (3)

U27RT (1)

Orange 14 1-1/16

Green 11

15/16

MY29-3 (1)
MY29-11 (1)
MRC840 (2)
Y644M (1)

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor

For CUSTOMER SERVICE call 1-800-346-4175

71

BURNDY
Telecommunications Products

TWO HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Fig. 1

Conductor
Catalog Number
YA28-2L516
YA28-2L516-45
YA28-2L516-90
YA282LN
YA282LN-45
YA282LN-90
YA28L-2TC14E1
YA28L-2TC14E1-45
YA28L-2TC14E1-90
YA28L-2TC14E2
YA28L-2TC14E2-45
YA28L-2TC14E2-90
YA28L-2TC38E2
YA28L-2TC38E2-45
YA28L-2TC38E2-90
YA28L-2TC38
YA28L-2TC38-45
YA28L-2TC38-90
YA292LN
YA292LN-45
YA292LN-90
YA29L-2TC38
YA29L-2TC38-45
YA29L-2TC38-90
YA302LN
YA302LN-45
YA302LN-90
YA30L-2TC-38
YA30L-2TC-38-45
YA30L-2TC-38-90
YA312LN
YA312LN-45
YA312LN-90
YA31L-2TC12
YA31L-2TC12-45
YA31L-2TC12-90
YA31L-2TC14E2
YA31L-2TC14E2-45
YA31L-2TC14E2-90
YA31L-2TC38
YA31L-2TC38-45
YA31L-2TC38-90
YA31L-2NTC516
YA31L-2NTC516-45
YA31L-2NTC516-90
YA322LN
YA322LN-45
YA322LN-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
5/16 1-3/4 1.02

1/2

1/4
4/0 AWG

250 kcmil

1.02

3/8

3/4

1.02

3/8

1

1.02

1-3/4 1.11

1

1.11

1-3/4 1.20

150
3/8

185

1

1.20

1/2

1-3/4 1.29

1/2

1-1/4

1.29

1/4

3/4

1.29

3/8

1

1.29

5/16 1-3/4 1.29

400 kcmil

1/2

-- Color code not assigned.


See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 volts consult cable manufacturer for voltage stress relief instructions.
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.

72

1.02

3/4

1/2

350 kcmil

1

1/4

3/8

300 kcmil

1-3/4 1.02

1/2

B
T

1-3/4 1.38

Figure
Dimensions
(B) (T)
(L)
3.84
.88 .14 3.77
2.92
4.41
.88 .14 4.34
3.49
3.03
.88 .14 2.96
2.11
2.78
.88 .14 2.71
1.86
2.97
.88 .14 2.90
2.05
3.22
.88 .14 3.15
2.30
4.62
1.06 .16 4.52
3.52
3.45
1.06 .16 3.33
2.34
4.63
1.03 .16 4.55
3.56
3.45
1.03 .16 3.36
2.37
4.70
1.06 .18 4.62
3.60
4.01
1.06 .18 3.93
2.91
3.07
1.06 .18 2.99
1.97
3.51
1.06 .18 3.43
2.41
4.13
1.06 .18 4.06
3.03
4.88
1.19 .19 4.78
3.64

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

MY29-3 (1)
MY29-11 (1)
MRC840 (2)
Y644M (1)

W28VT (2)
W28RT (2)
X28RT (3)

W28VT (2)
W28RT (2)
X28RT (3)

U28RT (1)

Purple 15

1-1/8

MY29-3 (1)
MY29-11 (1)
Y644M (1)

W29VT (2)
X29RT (4)

W29VT (2)
W29RT (2)
X29RT (4)

U29RT (1)

Yellow 16

1-1/8

W30VT (2)

W30VT (2)
W30RT (2)

U30RT (2)
U28ART (2)

White

17

1

W31VT (2)

W31VT (2)
W31RT (2)

U31RT (2)
U29ART (2)

Red

18

1-1/8

W32VT (2)

W32VT (2)
W32RT (2)

U32RT (2)
U30ART (2)

Blue

19

1-1/4

Y644M (1)

** P-RT die sets for use in Y46 HYPRESS only, PUADP-1


adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

TWO HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
YA32L-2TC38E5
YA32L-2TC38E5-45
YA32L-2TC38E5-90
YA32L-2TC38
YA32-2L
YA32-2L-45
YA32-2L-90
YA33-2LN
YA33-2LN-45
YA33-2LN-90
YA342LN
YA342LN-45
YA342LN-90
YA34L-2TC12
YA34L-2TC12-45
YA34L-2TC12-90
YA34L-2TC14E2
YA34L-2TC14E2-45
YA34L-2TC14E2-90
YA34L-2TC38
YA34L-2TC38-45
YA34L-2TC38-90
YA34-2L
YA34-2L-45
YA34-2L-90
YA35-2L
YA35-2L-45
YA35-2L-90
YA35-2LN
YA35-2LN-45
YA35-2LN-90
YA362LN
YA362LN45
YA362LN90
YA36L-2TC38
YA36L-2TC38-45
YA36L-2TC38-90
YA37-2L
YA37-2L-45
YA37-2L-90
YA37-2LN
YA37-2LN-45
YA37-2LN-90
YA38-2L
YA38-2L-45
YA38-2L-90
YA38-2LN
YA38-2LN-45
YA38-2LN-90

AWG

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8 1-1/16 1.40

400 kcmil

450 kcmil

3/8

1

1.38

3/8

1

1.40

1/2 1-3/4 1.48

1/2 1-3/4 1.52

1/2 1-1/4 1.52

500 kcmil 240

1/4

3/4

1.52

3/8

1

1.52

3/8

1

1.55

3/8 1-1/8 1.65


550 kcmil

1/2 1-3/4 1.65

1/2 1-3/4 1.74


600 kcmil 300
3/8

1

1.73

3/8 1-1/8 1.80


650 kcmil

1/2 1-3/4 1.80

3/8 1-1/8 1.84


700 kcmil

1/2 1-3/4 1.81

-- Color code not assigned.


See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 volts consult cable
manufacturer for voltage stress relief instructions.

Fig. 1

Conductor
Fig
#
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

B
T

Figure
Dimensions
(B) (T)
(L)
3.75
1.19 .19 3.66
2.52
1.19 .19 3.69
3.75
1.19 .19 3.66
2.52
5.23
1.50 .21 5.10
3.70
5.06
1.27 .23 5.00
3.73
4.38
1.27 .23 4.31
3.04
3.44
1.27 .23 3.37
2.10
3.88
1.27 .23 3.81
2.54
3.94
1.27 .23 3.87
2.59
4.64
1.69 .25 3.95
2.60
5.51
1.69 .25 5.07
3.73
4.36
1.38 .27 5.21
3.81
4.23
1.38 .27 4.21
2.81
4.40
1.39 .27 4.37
2.96
5.27
1.39 .27 5.25
3.84
4.48
1.45 .27 4.42
3.23
5.35
1.45 .27 5.29
3.84

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W32VT (2)

W32VT (2)
W32RT (2)

U32RT (2)
U30ART (2)

Blue

W33VT (2)

W33VT (2)
W33RT (2)

U33RT (2)

Gray 326 1-9/16

W34VT (2)

W34VT (2)
W34RT (2)

U34RT (2)
U31ART (2)

Brown

20 1-7/16

U35RT (2)

Yellow

21

1-3/4

U36RT (2)
U32ART (2)

Green

22

1-3/4

U37RT (2)

Orange 23

1-15/16

U38RT (2)

Pink

19

1-1/4

Y644M (1)

400 1-15/16

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

For CUSTOMER SERVICE call 1-800-346-4175

73

BURNDY
Telecommunications Products

TWO HOLE HYLUG


CODE CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
YA38L-2TC12
YA38L-2TC12-45
YA38L-2TC12-90
YA38L-2TC38
YA38L-2TC38-45
YA38L-2TC38-90
YA392L
YA392L-45
YA392L-90
YA392LN
YA392LN45
YA392LN-90
YA39L-2TC12E3
YA39L-2TC12E3-45
YA39L-2TC12E3-90
YA39L-2TC38
YA39L-2TC38-45
YA39L-2TC38-90
YA39L-2TC58
YA39L-2TC58-45
YA39L-2TC58-90
YA40-2L
YA40-2L-45
YA40-2L-90
YA402LN
YA402LN-45
YA402LN-90
YA40L-2TC38
YA40L-2TC38-45
YA40L-2TC38-90
YA41-2L
YA41-2L-45
YA41-2L-90
YA442LN
YA442LN-45
YA442LN-90
YA44-2L
YA44-2L-45
YA44-2L-90
YA44L-2TC12
YA44L-2TC12-45
YA44L-2TC12-90

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2 1-1/2 1.81

3/8

1.81

1/2 1-3/4 1.89

1/2 1-1/2 1.89

3/8

1

1.89

5/8 1-1/2 1.89

3/8 1-1/8 1.98

400

1/2 1-3/4 1.89

3/8

1

1.95

3/8 1-1/8 2.01

1/2 1-3/4 2.17

500

1/2 1-1/4 2.19

1/2 1-1/4 2.17

-- Color code not assigned.


See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 volts consult cable manufacturer for voltage stress relief instructions.
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.

74

1

3/8 1-1/8 1.91

Fig. 1

Conductor
Fig
#
AWG
1
2
3
700 kcmil
1
2
3
1
2
3
1
2
3
1
2 750 kcmil
3
1
2
3
1
2
3
1
2
3
1
2 800 kcmil
3
1
2
3
1
2 850 kcmil
3
1
2
3
1
2 1000 kcmil
3
1
2
3

B
T

Figure
Dimensions
(B) (T)
(L)
4.67
1.45 .27 4.61
3.16
4.35
1.45 .27 4.30
2.84
4.48
1.42 .27 4.43
3.00
5.36
1.42 .27 5.31
3.87
4.92
1.42 .27 4.87
3.43
4.36
1.42 .27 4.31
2.87
5.17
1.42 .27 5.12
3.68
4.63
1.42 .30 4.51
3.04
5.51
1.42 .30 5.39
3.91
4.51
1.42 .30 4.38
2.91
4.97
1.88 .31 4.86
3.05
5.74
1.65 .33 5.71
4.02
5.24
1.65 .33 5.21
3.52
5.05
1.65 .33 5.02
3.33

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

U38RT (2)

Pink

400 1-15/16

U39RT (2)
P39RT (2)
**

Black

24

1-15/16

P40RT (3)
**

Orange 25

1-15/16

Gold

26

1-15/16

**
P44RT (3)

White

27

1-15/16

Y644M (1)

** P-RT die sets for use in Y46 HYPRESS only, PUADP-1


adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
STANDARD BARREL
NARROW TONGUE

DIE AND COLOR


CODE INFORMATION

BEVELED
ENTRY

INSPECTION
WINDOW

TYPES YA-L-2NT

CRIMP
ELECTRO-TIN
PLATED

COPPER COMPRESSION
TERMINAL

CABLE
ACCOMMODATION

UL Listed 90 C,
600 Volts to 35 kV
B

B
T

Fig. 1

Fig. 2

Conductor
Catalog Number
YA2CL2NT14
YA2CL2NT1445
YA2CL2NT1490
YA2CL2NT14E2
YA2CL2NT14E1
YA2CL2NT14E145
YA2CL2NT14E190

Fig
#
1
2
3
1
1
2
3

YA1CL2NT14E2

YA25L2NT14E1

YA25L2NT14E145

YA25L2NT14E190

YA26L2NT14

AWG

#2 AWG

#1 AWG

***
MM2

35

50

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

5/8

.48

1/4

3/4

.48

1/4

1

.48

1/4

3/4

.50

Figure
Dimensions
(B) (T)
(L)
2.47
.88 .11 2.38
1.58
.88 .11 2.60
2.84
.88 .11 2.76
1.96

.88 .10 2.68

3.28
1/0 AWG

1/4

1

.48

.88 .12 2.83


1.95

70

1/4

5/8

.48

.94 0.12 2.66


.94 .12 3.03

2/0 AWG
YA26L2NT14E1

1/4

1

.48

YA31L2NT38
YA34L2NT38
YA39L2NT38
YA39L2NT3845
YA39L2NT3890

1
1
1
2
3

350 kcmil 185


500 kcmil 240

3/8
3/8

1
1

.96
.96

750 kcmil

3/8

1

1.06 .18 3.51


1.27 .23 3.65
4.34
1.63 1.42 .27 4.31
2.87

Dieless
(# of crimps)

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

MRC840 (1)
MY29-3 (1)
MY29-11 (1)
W2CVT (1) W2CVT (1)
Y2MR (2)
Y644M (1)
Y1MR (2)
MRC840 (1)
MY29-3 (1)
MY29-11 (1) W1CVT (1)
Y1MR (2)
Y644M (1)
MRC840 (2)
MY29-3 (1)
W25VT (2)
MY29-11 (1)
Y644M (1)
MRC840 (2)
MY29-3 (1)
W26VT (2)
MY29-11 (1)
Y644M (1)
W31VT (4)
W34VT (4)
Y644M (1)

Wire
Color Die Strip
Code Index Length

U2CRT (1)

Brown

10

15/16

W1CRT (1)

U1CRT (1)

Green

11

15/16

W25VT (1)

U25RT (1)

Pink

12

15/16

W26VT (1)
X26RT (1)

U26RT (1)

Black

13

1

W31VT (4)
W34VT (4)

U31RT (2)
U34RT (2)

Red
Brown

18 1-1/8
20 1-7/16

U39RT (2)

Black

24

1-1/2

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

For CUSTOMER SERVICE call 1-800-346-4175

75

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
LONG BARREL

DIE AND COLOR


CODE INFORMATION

BEVELED
ENTRY

NO INSPECTION
WINDOW

TYPES YA-2N, YA-2TC,


YA-4N

CRIMP

UL Listed 90 C,
600 Volts to 35 kV

ELECTRO-TIN
PLATED

CABLE
ACCOMMODATION

B
T

90

T
45

Fig. 1

Conductor
Catalog Number
YA8C2TC14
YA8C2TC14-45
YA8C2TC14-90
YA8C2TC14E2
YA8C2TC14E2-45
YA8C2TC14E2-90
YA8C2TC38
YA8C2TC38-45
YA8C2TC38-90
YA6C2N
YA6C2N-45
YA6C2N-90
YA6C2TC14
YA6C2TC14-45
YA6C2TC14-90
YA6C2TC14E1
YA6C2TC14E1-45
YA6C2TC14E1-90
YA6C2TC14E2
YA6C2TC14E2-45
YA6C2TC14E2-90
YA6C2TC38
YA6C2TC38-45
YA6C2TC38-90
YA6C2TC38E2
YA6C2TC38E2-45
YA6C2TC38E2-90
YA6C2TC38E6
YA6C2TC38E6-45
YA6C2TC38E6-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

#8 STR.

#6 SOL
10
37/24

#6 AWG

Stud Stud
Hole Hole Tongue
Size Spacing Width
.40
1/4 5/8 .40
.41
.41
1/4 3/4 .41
.41
.73
3/8
1
.73
.73
.81
1/2 1-3/4 .81
.81
.45
1/4 5/8 .45
.45
.45
1/4
1
.45
.45
.45
1/4 3/4 .45
.45
.63
3/8
1
.63
.63
.63
3/8 3/4 .63
.63
.63
3/8 7/8 .63
.63

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

76

Figure
Dimensions
(B) (T)
(L)
2.33
.81 .08 2.20
1.49
2.45
.81 .08 2.33
1.62
2.89
.81 .06 2.72
2.05
4.40
1.12 .12 4.29
3.28
2.65
1.12 .08 2.45
1.51
3.03
1.12 .08 2.83
1.88
2.78
1.12 .08 2.58
1.63
3.22
1.12 .06 2.97
2.06
2.97
1.12 .06 2.72
1.81
3.09
1.12 .06 2.85
1.94

Fig. 3

Fig. 2

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Y2MR (2)
Y8MRB-1 (2) W8CVT (2)
MY29-3 (2) W8CRT (2)
MY29-11 (2) X8CRT (2)
MRC840 (2)

Wire
Color Die Strip
Code Index Length

W8CVT (2)
W8CRT (2)
X8CRT (2)

U8CRT (1)

Red

49

1

Y1MR (2)
W5CVT (2) W5CVT (2)
Y2MR (2)
W5CRT (2) W5CRT (2)
MY29-3 (2)
X5CRT (2) X5CRT (2)
MY29-11 (2)
X8CART (2) X8CART (2)
MRC840 (2)

U5CRT (2)
U8CABT (2)

Blue

1-3/16

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
The MM2 conductor size listed here is for Class 2 and
Class 5 conductor.

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

Conductor
Catalog Number

Fig
#

YA5C2N
YA5C2N-45

1
2

YA5C2N-90
YA4C2N
YA4C2N-45
YA4C2N-90
YA4C2TC14
YA4C2TC14-45
YA4C2TC14-90
YA4C2TC14E2
YA4C2TC14E2-45
YA4C2TC14E2-90
YA4C2TC38
YA4C2TC38-45
YA4C2TC38-90
YA3C2N
YA3C2N-45
YA3C2N-90
YA3C2TC14
YA3C2TC14-45
YA3C2TC14-90
YA3C2TC14E2
YA3C2TC14E2-45
YA3C2TC14E2-90
YA3C2TC38
YA3C2TC38-45
YA3C2TC38-90
YA3C2TC38E2
YA3C2TC38E2-45
YA3C2TC38E2-90
YA2C2N
YA2C2N-45
YA2C2N-90
YA2C2TC14
YA2C2TC14-45
YA2C2TC14-90
YA2C2TC14E2
YA2C2TC14E2-45
YA2C2TC14E2-90
YA2C2TC38E2
YA2C2TC38E2-45
YA2C2TC38E2-90
YA2C2TC516E2
YA2C2TC516E2-45
YA2C2TC516E2-90
YA2C2NTC38
YA2C2NTC38-45
YA2C2NTC38-90

3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG
5 AWG

4 AWG

***
MM2

TWO HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)

Fig. 1

1-3/4

.83

Figure
Dimensions
(B) (T)
(L)
4.43
1.12 .12 4.31

1/2

1-3/4

.81

1.12 .12

1/4

5/8

.50

1.12 .09

25

1/4

3/4

.50

1.12 .09

3/8

1

.
.56

1.12 .08

1/2

1-3/4

.81

1.25 .12

1/4

5/8

.55

1.25 .09

1/4

3/4

.55

1.25 .09

3/8

1

.58

1.25 .08

3/8

3/4

.58

1.25 .08

1/2

1-3/4

.81

1.25 .12

1/4

5/8

.60

1.25 .11

1/4

3/4

.60

1.25 .11

#2 SOL

#2 AWG

35
3/8

3/4

.60

1.25 .11

5/16

3/4

.60

1.25 .11

3/8

1-3/4

.60

1.25 .11

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

T
45

#3 STR
# 3 AWG

90

T
L

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2

B
T

3.28
4.45
4.32
3.30
2.70
2.51
1.54
2.83
2.64
1.66
3.26
3.03
2.09
4.62
4.44
3.32
2.87
2.62
1.55
2.99
2.75
1.68
3.43
3.16
2.11
3.18
2.91
1.86
4.64
4.46
3.34
2.86
2.66
1.58
2.98
2.78
1.71
3.17
2.97
1.90
3.05
2.84
1.77
4.17
3.97
2.90

Dieless
(# of crimps)

MY29-3 (2)
MY29-1 (2)
MRC840 (2)
Y644M (1)

Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
Y644M (1)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W5CRT (2)
W5CVT (2)
X5CRT (2)

X5CRT (2)
X5CVT (2)
W5CRT (2)

U5CRT (2)

Blue

1-3/16

W4CVT (2)
W4CRT (2)
X4CRT (2)

W4CVT (2)
W4CRT (2)
X4CRT (2)

U4CRT (2)
U6CABT (2)

Gray

1-3/16

W3CRT (2)

W3CRT (2)

U3CRT (2)

White

1-5/16

W2CVT (2)
W2CRT (2)
X2CRT (2)

W2CVT (2)
W2CRT (2)
X2CRT (2)

U2CRT (2)

Brown 10

1-5/16

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

77

BURNDY
Telecommunications Products

Conductor
Catalog Number
YA2C2TC38
YA2C2TC38-45
YA2C2TC38-90
YA2C2TC38E6
YA2C2TC38E6-45
YA2C2TC38E6-90
YA2C2TC516E2
YA2C2TC516E2-45
YA2C2TC516E2-90
YA1C2N
YA1C2N-45
YA1C2N-90
YA1C2TC14
YA1C2TC14-45
YA1C2TC14-90
YA1C2TC14E2
YA1C2TC14E2-45
YA1C2TC14E2-90
YA1C2TC38
YA1C2TC38-45
YA1C2TC38-90
YA252N
YA252N-45
YA252N-90
YA252TC14
YA252TC14-45
YA252TC14-90
YA252TC14E2
YA252TC14E2-45
YA252TC14E2-90
YA252TC38
YA252TC38-45
YA252TC38-90
YA252TC516
YA252TC516-45
YA252TC516-90
YA252NTC38
YA252NTC38-45
YA252NTC38-90
YA262N
YA262N-45
YA262N-90
YA262TC14
YA262TC14-45
YA262TC14-90
YA262TC14E2
YA262TC14E2-45
YA262TC14E2-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

#2 AWG

1 AWG

1/0 AWG

***
MM2

35

78

T
45

Fig. 1

3/8

1

.60

3/8

7/8

.60

5/16

3/4

.60

1/2

1-3/4

.81

1/4

5/8

.68

1/4

3/4

.75

3/8

1

.68

1/2

1-3/4

.81

1/4

5/8

.75

1/4

3/4

.75

1

.75

5/16

1

.75

3/8

1-3/4

.75

1/2

1-3/4

.83

1/4

5/8

.
.83

1/4

3/4

.
.83

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

90

T
L

50

70

B
T

Stud Stud
Hole Hole Tongue
Size Spacing Width

3/8

2/0 AWG

TWO HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)
Figure
Dimensions
(B) (T)
(L)
3.42
1.25 .11 3.22
2.14
3.30
1.25 .11 3.10
2.02
3.05
1.25 .11 2.84
1.77
4.82
1.38 .12 4.58
3.36
3.03
1.38 .10 2.76
1.60
3.15
1.38 .10 2.88
1.73
3.59
1.38 .10 3.32
2.16
4.81
1.38 .11 4.56
3.38
3.05
1.38 .12 2.82
1.64
3.18
1.38 .12 2.94
1.76
3.62
1.38 .12 3.38
2.20
3.49
1.38 .12 3.26
2.08
4.37
1.38 .12 4.13
2.95
4.97
1.50 .12 4.69
3.41
3.22
1.50 .12 2.94
1.66
3.34
1.50 .12 3.06
1.79

Dieless
(# of crimps)

Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
Y644M (1)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

W2CVT (2)
W2CRT (2)
X2CRT (2)

Wire
Color Die Strip
Code Index Length

W2CVT (2)
W2CRT (2)
X2CRT (2)

U2CRT (2)

Brown 10

1-5/16

Y1MR (4)
MY29-3 (2) W1CVT (2) W1CVT (2)
MY29-11 (2) W1CRT-1 (2) W1CRT-1 (2)
MRC840 (2) X1CRT-1 (2) X1CRT-1 (2)
Y644M (1)

U1CRT-1 (2)
U4CABT (2)

Green 11

1-1/2

W25VT (4)
W25RT (4)
X25RT (4)

W25VT (4)
W25RT (4)
X25RT (4)

U25RT (2)
U2CABT (2)

Pink

12

1-7/16

W26VT (4)
W26RT (4)
X26RT (4)

W26VT (4)
W26RT (4)
X26RT (4)

U26RT (2)

Black

13

1-9/16

MY29-3 (2)
MY29-11 (2)
MRC840 (4)
Y644M (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

Conductor
Catalog Number
YA262TC38
YA262TC38-45
YA262TC38-90
YA272N
YA272N-45
YA272N-90
YA272TC14E2
YA272TC14E2-45
YA272TC14E2-90
YA272TC38
YA272TC38-45
YA272TC38-90
YA282N
YA282N-45
YA282N-90
YA282TC38
YA282TC38-45
YA282TC38-90
YA282TC14E2
YA282TC14E2-45
YA282TC14E2-90
YA282NTC38
YA282NTC38-45
YA282NTC38-90
YA292N
YA292N-45
YA292N-90
YA292TC38
YA292TC38-45
YA292TC38-90
YA302TC38
YA302TC38-45
YA302TC38-90
YA302N
YA302N-45
YA302N-90
YA312N
YA312N-45
YA312N-90
YA312TC14E2
YA312TC14E2-45
YA312TC14E2-90
YA312TC38
YA312TC38-45
YA312TC38-90
YA322N
YA322N-45
YA322N-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

TWO HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)

Fig. 1

AWG
2/0 AWG

70

3/8

1

.83

1/2

1-3/4

.91

1/4

3/4

.91

3/8

1

.90

1/2

3/8
4/0 AWG

250 kcmil

300 kcmil

350 kcmil

400 kcmil

1-3/4 1.02

1

1.02

1/4

3/4

1.02

3/8

1-3/4 1.02

1/2

1-3/4 1.11

3/8

1

1.10

3/8

1

1.20

150

185

1/2

1-3/4 1.20

1/2

1-3/4 1.29

1/4

3/4

1.29

3/8

1

1.29

1/2

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

T
45

***
MM2

90

T
L

Stud Stud
Hole Hole Tongue
Size Spacing Width

3/0 AWG

B
T

1-3/4 1.38

Figure
Dimensions
(B) (T)
(L)
3.78
1.50 .12 3.50
2.22
5.01
1.50 .13 4.73
3.44
3.38
1.50 .12 3.10
1.82
3.82
1.50 .12 3.54
2.25
5.17
1.62 .14 4.88
3.49
3.99
1.62 .14 3.69
2.30
3.55
1.62 .14 3.25
1.86
4.74
1.62 .14 4.44
3.05
5.21
1.62 .16 4.94
3.52
4.02
1.62 .16 3.75
2.34
4.45
2.00 .16 4.07
2.37
5.64
2.00 .16 5.26
3.56
5.68
2.00 .18 5.31
3.60
4.05
2.00 .18 3.68
1.97
4.49
2.00 .18 4.12
2.41
5.85
2.12 .19 5.47
3.64

Dieless
(# of crimps)

Mechanical
MD6, OUR840,
MD7-34R
W26VT (4)
W26RT (4)
X26RT (4)

Fig. 2

Fig. 3

Installation Tooling
Hydraulic
BCT500HS,
Y35,Y39,Y750,
Y500CTHS
Y46*, PAT750
W26VT (4)
W26RT (4)
U26RT (2)
X26RT (4)

Wire
Color Die Strip
Code Index Length
Black

13

1-9/16

W27VT (4)
W27RT (4)
X27RT (6)

W27VT (4)
W27RT (4)
X27RT (6)

U27RT (2)

Orange 14

1-9/16

W28VT (4)
W28RT (4)
X28RT (6)

W28VT (4)
W28RT (4)
X28RT (6)

U28RT (2)

Purple

15

1-11/16

W29VT (4)
X29RT (8)

W29VT (4)
W29RT (4)
X29RT (8)

U29RT (2)

Yellow 16

1-11/16

W30VT (4)

W30VT (4)
W30RT (4)

U30RT (4)
U28ART (4)

White

17

2

W31VT (4)

W31VT (4)
W31RT (4)

U31RT (4)
U29ART (4)

Red

18

2-1/16

W32VT (4)

W32VT (4)
W32RT (4)

U32RT (4)
U30ART (4)

Blue

19

2-3/16

MY29-3 (2)
MY29-11 (2)
MRC840 (4)
Y644M (1)

MY29-3 (2)
MY29-11 (2)
Y644M (1)

Y644M (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).

For CUSTOMER SERVICE call 1-800-346-4175

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

79

BURNDY
Telecommunications Products

Conductor
Catalog Number
YA322TC38
YA322TC38-45
YA322TC38-90
YA332N
YA332N-45
YA332N-90
YA342N
YA342N-45
YA342N-90
YA342TC14E2
YA342TC14E2-45
YA342TC14E2-90
YA342TC38
YA342TC38-45
YA342TC38-90
YA352N
YA352N-45
YA352N-90
YA362N
YA362N-45
YA362N-90
YA362TC38
YA362TC38-45
YA362TC38-90
YA372N
YA372N-45
YA372N-90
YA382N
YA382N-45
YA382N-90
YA382TC38
YA382TC38-45
YA382TC38-90
YA392N
YA392N-45
YA392N-90
YA392NT38
YA392NT38-45
YA392NT38-90
YA392TC38
YA392TC38-45
YA392TC38-90
YA402N
YA402N-45
YA402N-90
YA412N
YA412N-45
YA412N-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

Fig. 1

400 kcmil

3/8

450 kcmil

1/2

1-3/4 1.48

1/2

1-3/4 1.52

550 kcmil

600 kcmil

300

650 kcmil

700 kcmil

1.38

3/4

1.55

3/8

1

1.55

1/2

1-3/4 1.65

1/2

1-3/4 1.69

1

1.74

1/2

1-3/4 1.80

1/2

1-3/4 1.84

3/8

1/2

750 kcmil

1

1/4

3/8

T
45

AWG

240

90

T
L

***
MM2

500 kcmil

B
T

Stud Stud
Hole Hole Tongue
Size Spacing Width

1

1.84

1-3/4 1.89

3/8

1

1.63

3/8

1

1.91

800 kcmil

400

1/2

1-3/4 1.95

850 kcmil

1/2

1-3/4 2.01

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

80

TWO HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)
Figure
Dimensions
(B) (T)
(L)
4.66
2.12 .19 4.28
2.46
5.93
2.12 .21 5.57
3.70
6.06
2.25 .23 5.72
3.73
4.46
2.25 .23 4.09
2.10
4.90
2.25 .23 4.53
2.54
6.49
2.63 .25 6.06
3.77
6.59
6.17
2.69 .27 3.81
5.59
2.69 .26 5.17
2.81
6.74
2.81 .27 6.29
3.84
6.77
2.81 .27 6.29
3.84
5.76
2.81 .27 5.29
2.84
6.87
2.88 .27 6.38
3.87
5.87
2.88 .27 5.38
2.87
5.87
2.88 .27 5.38
2.87
6.95
2.94 .30 6.50
3.91
6.96
2.94 .31 6.52
3.93

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W32VT (4)

W32VT (4)
W32RT (4)

U32RT (4)
U30RT (4)

Blue

19

W33VT (4)

W33VT (4)
W33RT (4)

U33RT

Gray

326

W34VT (4)

W34VT (4)
W34RT (4)

U34RT (4)
U31ART (4)

Brown

20

2-1/2

U35RT (4)

Yellow

21

2-11/16

U36RT (4)
U32ART (4)

Green

22

2-3/4

U37RT (4)

Orange 23

2-7/8

U38RT (4)

Pink

400

2-7/8

U39RT (4)
P39RT (4)
**

Black

24

2-3/4

P40RT (4)
**

2-3/16
2-3/16
2-5/16

Y644M (1)

Orange 25

3

Gold

3

26

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

Conductor
Catalog Number
YA442N
YA442N-45
YA442N-90
YA442TC38
YA442TC38-45
YA442TC38-90
YA452N
YA452N-45
YA452N-90
YA4532N
YA4532N-45
YA4532N-90
YA462N
YA462N-45
YA462N-90
YA472N
YA472N-45
YA472N-90
YA482N
YA482N-45
YA482N-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

TWO HOLE HYLUG


CODE CONDUCTOR
LONG BARREL
(Continued)

Fig. 1

1-3/4 2.17

1

2.19

1250 kcmil

1/2

1-3/4 2.46

1300 kcmil

1/2

1-3/4 2.53

1500 kcmil

1/2

1-3/4 2.67

1750 kcmil

1/2

1-3/4 2.90

2000 kcmil

1/2

1-3/4 3.10

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

T
45

1000 kcmil 500


3/8

90

T
L

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2

B
T

Figure
Dimensions
(B) (T)
(L)
7.14
3.00 .33 6.71
4.02
6.14
3.00 .33 5.71
3.02
7.44
3.19 .38 7.03
4.13
7.48
3.19 .39 7.07
4.16
7.55
3.19 .40 7.15
4.22
7.89
3.44 .42 7.45
4.30
7.98
3.44 .46 7.60
4.40

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Y644M (1)

Wire
Color Die Strip
Code Index Length

P44RT (4)
**

White

27

3-1/16

P45RT (6)
**

Yellow

29

3-1/4

Orange 30

3-1/4
2-1/16

P46RT (6)
**

Green

31

3-1/4

Gray

33

3-1/2

Brown

34

3-1/2

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

81

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW

DIE AND COLOR


CODE INFORMATION

BEVELED
ENTRY

INSPECTION
WINDOW

CRIMP

TYPES YAZ-2N, YAZ-2TC


UL Listed 90 C,
600 Volts to 35 kV

ELECTRO-TIN
PLATED

CABLE
ACCOMMODATION

90

T
45

Conductor
Catalog Number
YAZV10-2TC14
YAZV10-2TC14-45
YAZV10-2TC14-90
YAZV10-2TC14E2
YAZV10-2TC14E2-45
YAZV10-2TC14E2-90
YAZ8C-2TC10
YAZ8C-2TC10-45
YAZ8C-2TC10-90
YAZ8C-2TC10E2
YAZ8C-2TC10E2-45
YAZ8C-2TC10E2-90
YAZ8C-2TC14
YAZ8C-2TC14-45
YAZ8C-2TC14-90
YAZ8C-2TC14E2
YAZ8C-2TC14E2-45
YAZ8C-2TC14E2-90
YAZ8C-2TC14E1
YAZ8C-2TC14E1-45
YAZ8C-2TC14E1-90
YAZ8C-2TC38
YAZ8C-2TC38-45
YAZ8C-2TC38-90
YAZ6C-2N
YAZ6C-2N-45
YAZ6C-2N-90
YAZ6C-2TC10E2
YAZ6C-2TC10E2-45
YAZ6C-2TC10E2-90

Fig
***
#
AWG
MM2
1
2
3
14-10 AWG 6
1
2
3
1
2
3
1
2
3
1
#8 STR
2

3
#6 SOL
1
10
2
37/24
3
1
2
3
1
2
3
1
2
3
#6 AWG
1
2
3

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

.41

1/4

3/4

.41

#10

5/8

.41

#10

3/4

.41

1/4

5/8

.44

1/4

3/4

.44

1/4

1

.44

3/8

1

.58

1/2

1-3/4

.83

#10

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

82

5/8

3/4

.42

Fig. 1

Fig. 2

Fig. 3

Figure
Dimensions
(B) (T)
(L)
2.16
.69 .05 2.03
1.45
2.28
.69 .05 2.16
1.58
2.20
.75 .08 2.09
1.37
2.33
.75 .08 2.22
1.50
2.33
.75 .08 2.20
1.49
2.45
.75 .08 2.33
1.62
2.70
.75 .08 2.58
1.87
2.89
.75 .06 2.72
2.05
4.40
1.12 .12 4.29
3.28
2.65
1.12 .09 2.48
1.51

Dieless
(# of crimps)

Y8MRB-1 (2)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

3/4

W8CVT (2)
W8CRT (2)
X8CRT (2)

U8CRT (2)

Red

49

7/8

Y2MR (2)
MY29-3 (2) W5CVT (2) W5CVT (2)
MY29-11 (2) W5CRT (2) X5CRT (2)
MRC840 (2) X5CRT (2) X5CRT (2)
Y644M (1) X8CART (2) X8CART (2)
Y1MR (2)

U5CRT (2)
U8CABT (2)

Blue

7 or
1-1/16
374

Y1MR (2)
Y8MRB-1 (2)
W8CVT (2)
Y2MR (2)
W8CRT (2)
MY29-3 (2)
X8CRT (2)
MY29-11 (2)
MRC840 (2)

The MM2 conductor size referred to here is for Class 2 and


Class 5 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
Catalog Number
YAZ6C-2TC14
YAZ6C-2TC14-45
YAZ6C-2TC14-90
YAZ6C-2TC14E2
YAZ6C-2TC14E2-45
YAZ6C-2TC14E2-90
YAZ6C-2TC14E1
YAZ6C-2TC14E1-45
YAZ6C-2TC14E1-90
YAZ6C-2TC38E2
YAZ6C-2TC38E2-45
YAZ6C-2TC38E2-90
YAZ6C-2TC38E6
YAZ6C-2TC38E6-45
YAZ6C-2TC38E6-90
YAZ6C-2TC38
YAZ6C-2TC38-45
YAZ6C-2TC38-90
YAZ5C-2N
YAZ5C-2N-45
YAZ5C-2N-90
YAZ4C-2N
YAZ4C-2N-45
YAZ4C-2N-90
YAZ4C-2TC10-E2
YAZ4C-2TC10-E245
YAZ4C-2TC10-E290
YAZ4C-2TC14
YAZ4C-2TC14-45
YAZ4C-2TC14-90
YAZ4C-2TC14E2
YAZ4C-2TC14E2-45
YAZ4C-2TC14E2-90
YAZ4C-2TC38
YAZ4C-2TC38-45
YAZ4C-2TC38-90
YAZ3C-2N
YAZ3C-2N-45
YAZ3C-2N-90
YAZ3C-2TC14
YAZ3C-2TC14-45
YAZ3C-2TC14-90
YAZ3C-2TC14E2
YAZ3C-2TC14E2-45
YAZ3C-2TC14E2-90
YAZ3C-2TC38E2
YAZ3C-2TC38E2-45
YAZ3C-2TC38E2-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

#6 AWG

#5 AWG

#4 AWG

***
MM2

B
T

#3 AWG

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

5/8

.45

1/4

3/4

.45

1/4

1

.45

3/8

3/4

.58

3/8

7/8

.58

3/8

1

.58

1/2

1-3/4

.83

1/2

1-3/4

.83

#10

3/4

.49

1/4

5/8

.49

1/4

3/4

.49

3/8

1

.
.58

1/2

1-3/4

.83

1/4

5/8

.55

25
#2 SOL

1/4

3/4

.55

3/8

3/4

.58

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

90
T

T
45

Figure
Dimensions
(B) (T)
(L)
2.65
1.12 .08 2.45
1.51
2.78
1.12 .08 2.58
1.63
3.03
1.12 .08 2.83
1.63
2.97
1.12 .06 2.72
1.81
3.09
1.12 .06 2.85
1.94
3.22
1.12 .06 2.97
2.06
4.43
1.12 .12 4.31
3.28
4.42
1.12 .12 4.30
3.30
2.67
1.12 .09 2.49
1.54
2.67
1.12 .09 2.49
1.54
2.80
1.12 .09 2.61
1.66
3.23
1.12 .08 3.01
2.09
4.58
1.25 .12 4.41
3.32
2.83
1.25 .09 2.59
1.55
2.95
1.25 .09 2.72
1.68
3.14
1.25 .08 2.88
1.86

Fig. 1

Fig. 2

Fig. 3

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Y1MR (2)
W5CVT (2) W5CVT (2)
Y2MR (2)
W5CRT (2) X5CRT (2)
MY29-3 (2) X5CRT (2) X5CRT (2)
MY29-11 (2) X8CART (2) X8CART (2)
MRC840 (2)
Y644M (2)

U5CRT (2)
U8CABT (2)

Blue

7 or
374

1-1/6

1/16

W5CRT (2)
W5CVT (2)
X5CRT (2)

W5CVT (2)
W5CRT (2)
X5CRT (2)

U5CRT (2)

Blue

7 or
374

W4CVT (2)
W4CRT (2)
X4CRT (2)

W4CVT (2)
W4CRT (2)
X4CRT (2)

U4CRT (2)
U6CABT (2)

Gray

8 or
1-1/16
346

W3CRT (2)

W3CRT (2)

U3CRT (2)

White

Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
Y644M (2)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).

For CUSTOMER SERVICE call 1-800-346-4175

Wire
Color Die Strip
Code Index Length

1-5/16

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

83

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
Catalog Number
YAZ3C-2TC38
YAZ3C-2TC38-45
YAZ3C-2TC38-90
YAZ2C-2N
YAZ2C-2N-45
YAZ2C-2N-90
YAZ2C-2TC10E2
YAZ2C-2TC10E2-45
YAZ2C-2TC10E2-90
YAZ2C-2TC14
YAZ2C-2TC14-45
YAZ2C-2TC14-90
YAZ2C-2TC14E2
YAZ2C-2TC14E2-45
YAZ2C-2TC14E2-90
YAZ2C-2TC14E1
YAZ2C-2TC14E1-45
YAZ2C-2TC14E1-90
YAZ2C-2TC516E2
YAZ2C-2TC516E2-45
YAZ2C-2TC516E2-90
YAZ2C-2TC38E2
YAZ2C-2TC38E2-45
YAZ2C-2TC38E2-90
YAZ2C-2TC38E6
YAZ2C-2TC38E6-45
YAZ2C-2TC38E6-90
YAZ2C-2TC38
YAZ2C-2TC38-45
YAZ2C-2TC38-90
YAZ2C-2NTC38
YAZ2C-2NTC38-45
YAZ2C-2NTC38-90
YAZ1C-2N
YAZ1C-2N-45
YAZ1C-2N-90
YAZ1C-2TC14
YAZ1C-2TC14-45
YAZ1C-2TC14-90
YAZ1C-2TC14E2
YAZ1C-2TC14E2-45
YAZ1C-2TC14E2-90
YAZ1C-2TC38
YAZ1C-2TC38-45
YAZ1C-2TC38-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

YAZ25-2N
YAZ25-2N-45
YAZ25-2N-90

1
2
3

AWG
#3 AWG
#2 SOL

#2 AWG

#1 AWG

1/0 AWG

***
MM2
25

3/8

1

.58

1/2 1-3/4

.83

#10

3/4

.60

1/4

5/8

.60

1/4

3/4

.60

1/4

1

.60

5/16

3/4

.60

3/8

3/4

.60

3/8

7/8

.60

3/8

1

.60

35

3/8 1-3/4

.60

1/2 1-3/4

.83

1/4

.67

5/8

50

B
90
T

T
45

Stud Stud
Hole Hole Tongue
Size Spacing Width

1/4

3/4

.67

3/8

1

.67

1/2 1-3/4

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.

84

B
B

.83

Figure
Dimensions
(B) (T)
(L)
3.39
1.25 .08 3.13
2.11
4.60
1.25 .12 4.32
3.32
2.85
1.25 .11 2.65
1.58
2.85
1.25 .11 2.65
1.58
2.97
1.25 .11 2.77
1.71
3.22
1.25 .11 3.02
1.96
3.03
1.25 .11 2.84
1.77
3.16
1.25 .11 2.96
1.90
3.28
1.25 .11 3.09
2.02
3.41
1.25 .11 3.21
2.14
4.16
1.25 .11 3.96
2.90
4.76
1.38 .12 4.45
3.34
3.01
1.38 .10 2.75
1.60
3.13
1.38 .10 2.87
1.73
3.57
1.38 .10 3.31
2.16
4.79
1.38 .11 4.52
3.38

Fig. 1

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W3CRT (2) W3CRT (2)

U3CRT (2)

White

U2CRT (2)

Brown

10 1-5/16

Y1MR (4)
MY29-3 (2) W1CVT (2) W1CVT (2)
MY29-11 (2) W1CRT-1 (2) W1CRT-1 (2)
MRC840 (2) X1CRT-1 (2) X1CRT-1 (2)
Y644M (1)

U1CRT-1 (2)
U4CABT (2)

Green

11 or
1-7/16
375

MY29-3 (2)
W25RT (4) W25VT (4)
MY29-11 (2)
MRC840 (4) W25VT (4) X25RT (4)
Y644M (1) X25RT (4) W25RT (4)

U25RT (2)
U2CABT (2)

Pink

12 or
1-7/16
348

Dieless
(# of crimps)

Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2) W2CVT (2) W2CVT (2)
Y644M (1) W2CRT (2) W2CRT (2)
X2CRT (2) X2CRT (2)

** P-RT die sets for use in Y46 HYPRESS only, PUADP-1


adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

1-5/16

Available undrilled. Add suffix "U" to catalog number


(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
Catalog Number
YAZ25-2TC14
YAZ25-2TC14-45
YAZ25-2TC14-90
YAZ25-2TC14E2
YAZ25-2TC14E2-45
YAZ25-2TC14E2-90
YAZ25-2TC14E1
YAZ25-2TC14E1-45
YAZ25-2TC14E1-90
YAZ25-2TC516E6
YAZ25-2TC516E6-45
YAZ25-2TC516E6-90
YAZ25-2TC516
YAZ25-2TC516-45
YAZ25-2TC516-90
YAZ25-2TC38
YAZ25-2TC38-45
YAZ25-2TC38-90
YAZ25-2NTC38
YAZ25-2NTC38-45
YAZ25-2NTC38-90
YAZ26-2N
YAZ26-2N-45
YAZ26-2N-90
YAZ26-2TC14
YAZ26-2TC14-45
YAZ26-2TC14-90
YAZ26-2TC14E2
YAZ26-2TC14E2-45
YAZ26-2TC14E2-90
YAZ26-2TC38
YAZ26-2TC38-45
YAZ26-2TC38-90
YAZ27-2N
YAZ27-2N-45
YAZ27-2N-90
YAZ27-2TC14E2
YAZ27-2TC14E2-45
YAZ27-2TC14E2-90
YAZ27-2TC38
YAZ27-2TC38-45
YAZ27-2TC38-90
YAZ28-2N
YAZ28-2N-45
YAZ28-2N-90
YAZ28-2TC14E2
YAZ28-2TC14E2-45
YAZ28-2TC14E2-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

1/0 AWG

2/0 AWG

3/0 AWG

4/0 AWG

***
MM2

B
T

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

5/8

1/4

3/4

1/4

1

5/16

7/8

5/16

1

3/8

1

3/8

1-3/4

1/2

1 3/4

1/4

5/8

1/4

3/4

3/8

1

1/2

1-3/4

1/4

3/4

3/8

1

1/2

1-3/4

1/4

See tooling section of this catalog for complete tool and


die listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

90
T

T
45

70

3/4

Figure
Dimensions
(B) (T)
(L)
3.04
.75 1.38 .12 2.81
1.64
3.16
.75 1.38 .12 2.93
1.76
3.41
.75 1.38 .12 3.18
2.01
3.35
.75 1.38 .12 3.12
1.95
3.47
.75 1.38 .12 3.24
2.08
3.60
.75 1.38 .12 3.37
2.20
4.35
.75 1.38 .12 4.12
2.95
4.95
.83 1.50 .12 4.67
3.41
3.20
.83 1.50 .12 2.92
1.66
3.32
.83 1.50 .12 3.05
1.79
3.76
.83 1.50 .12 3.48
2.22
4.98
.91 1.50 .13 4.71
3.44
3.36
.90 1.50 .12 3.08
1.82
3.80
.90 1.50 .12 3.52
2.25
5.15
1.02 1.62 .14 4.86
3.48
3.55
1.02 1.62 .14 3.25
1.86

Fig. 1

Fig. 2

Fig. 3

Dieless
(# of crimps)

MY29-3 (2)
MY29-11 (2)
MRC840 (4)
Y644M (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

W25RT (4)
W25VT (4)
X25RT (4)

W25VT (4)
W25RT (4)
W25RT (4)

U25RT (2)
U2CABT (2)

Pink

W26VT (4)
W26RT (4)
X26RT (4)

W26VT (4)
W26RT (4)
X26RT (4)

U26RT (2)

Black

13

1-9/16

W27VT (4)
W27RT (4)
X27RT (6)

W27VT (4)
W27RT (4)
X27RT (6)

U27RT (2)

Orange 14

1-9/16

W28VT (4)
W28RT (4)
X28RT (6)

W28VT (4)
W28RT (4)
X28RT (6)

U28RT (2)

Purple 15

1-11/16

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).

For CUSTOMER SERVICE call 1-800-346-4175

Wire
Color Die Strip
Code Index Length

12 or
1-7/16
348

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

85

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
Catalog Number
YAZ28-2TC38
YAZ28-2TC38-45
YAZ28-2TC38-90
YAZ28-2NTC38
YAZ28-2NTC38-45
YAZ28-2NTC38-90
YAZ29-2N
YAZ29-2N-45
YAZ29-2N-90
YAZ29-2TC38
YAZ29-2TC38-45
YAZ29-2TC38-90
YAZ30-2N
YAZ30-2N-45
YAZ30-2N-90
YAZ30-2TC38
YAZ30-2TC38-45
YAZ30-2TC38-90
YAZ31-2N
YAZ31-2N-45
YAZ31-2N-90
YAZ31-2TC14E2
YAZ31-2TC14E2-45
YAZ31-2TC14E2-90
YAZ31-2TC38
YAZ31-2TC38-45
YAZ31-2TC38-90
YAZ32-2N
YAZ32-2N-45
YAZ32-2N-90
YAZ32-2TC38
YAZ32-2TC38-45
YAZ32-2TC38-90
YAZ33-2N
YAZ33-2N-45
YAZ33-2N-90
YAZ34-2N
YAZ34-2N-45
YAZ34-2N-90
YAZ34-2TC14E2
YAZ34-2TC14E2-45
YAZ34-2TC14E2-90
YAZ34-2TC38
YAZ34-2TC38-45
YAZ34-2TC38-90
YAZ35-2N
YAZ35-2N-45
YAZ35-2N-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

250 kcmil

300 kcmil

1/2

1-3/4 1.10

185

550 kcmil

1

1.20

1-3/4 1.29

1.29

3/8

1

1.29

1-3/4 1.40

240

1

1.40

1/2

1-3/4 1.48

1/2

1-3/4 1.55

1/4

3/4

1.55

3/8

1

1.55

1/2

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

86

1-3/4 1.20

3/4

3/8

500 kcmil

1.10

1/4

1/2

450 kcmil

1

150

1/2

400 kcmil

1.02

1-3/4 1.02

3/8

350 kcmil

1

3/8

1/2

T
45

3/8

B
90

Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8

4/0 AWG

B
B

1-3/4 1.65

Figure
Dimensions
(B) (T)
(L)
3.99
1.62 .14 3.69
2.30
4.74
1.62 .14 4.44
3.05
5.18
1.62 .16 4.92
3.52
3.99
1.62 .14 3.73
2.34
5.60
2.00 .16 5.23
3.56
4.42
2.00 .16 4.04
2.37
5.64
2.00 .18 5.29
3.60
4.02
2.00 .18 3.66
1.97
4.45
2.00 .18 4.10
2.41
5.81
2.12 .19 5.44
3.64
4.62
2.12 .19 4.25
2.46
5.89
2.13 .21 5.54
3.70
6.04
2.25 .23 5.69
3.73
4.42
2.25 .23 4.06
2.10
4.85
2.25 .23 4.50
2.54
6.45
2.63 .25 6.03
3.77

Fig. 1

Fig. 2

Fig. 3

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

MY29-3 (2)
MY29-11 (2)
MRC840 (4)
Y644M (1)

W28VT (4)
W28RT (4)
X28RT (6)

W28VT (4)
W28RT (4)
X28RT (6)

U28RT (2)

Purple 15

1-11/16

MY29-3 (2)
MY29-11(2)
Y644M (1)

W29VT (4)
X29RT (8)

X29RT (8)
W29VT (4)
W29RT (4)

U29RT (2)

Yellow

1-11/16

W30VT (4)

W30VT (4)
W30RT (4)

U30RT (4)
U28ART (4)

White

17 or
2-1/16
298

W31VT (4)

W31VT (4)
W31RT (4)

U31RT (4)
U29ART (4)

Red

18 or
2-1/16
324

W32VT (4)

W32VT (4)
W32RT (4)

U32RT (4)
U30ART (4)

Blue

19 or
2/16
470

W33VT (4)

W33VT (4)
W33RT (4)

U33RT (4)

Gray

326 or
2-5/16
538

W34VT (4)

W34VT (4)
W34RT (4)

U34RT (4)
U31ART (4)

Brown

20 or
2-5/16
299

U35RT (4)

Yellow

Y644M (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).

16

21

2-11/16

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
Catalog Number
YAZ36-2N
YAZ36-2N-45
YAZ36-2N-90
YAZ36-2TC38
YAZ36-2TC38-45
YAZ36-2TC38-90
YAZ37-2N
YAZ37-2N-45
YAZ37-2N-90
YAZ38-2N
YAZ38-2N-45
YAZ38-2N-90
YAZ39-2N
YAZ39-2N-45
YAZ39-2N-90
YAZ39-2NT38
YAZ39-2NT38-45
YAZ39-2NT38-90
YAZ39-2TC38
YAZ39-2TC38-45
YAZ39-2TC38-90
YAZ39-2NNT
YAZ39-2NNT-45
YAZ39-2NNT-90
YAZ40-2N
YAZ40-2N-45
YAZ40-2N-90
YAZ41-2N
YAZ41-2N-45
YAZ41-2N-90
YAZ44-2N
YAZ44-2N-45
YAZ44-2N-90
YAZ44-2TC38
YAZ44-2TC38-45
YAZ44-2TC38-90
YAZ45-2N
YAZ45-2N-45
YAZ45-2N-90
YAZ453-2N
YAZ453-2N-45
YAZ453-2N-90
YAZ46-2N
YAZ46-2N-45
YAZ46-2N-90
YAZ47-2N
YAZ47-2N-45
YAZ47-2N-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

1-3/4 1.74

1

1.74

650 kcmil

1/2

1-3/4 1.80

700 kcmil

1/2

1-3/4 1.84

1/2

1-3/4 1.91

3/8
750 kcmil

1

1.63

3/8

1

1.91

1/2

1-3/4 1.63

800 kcmil

400

1/2

1-3/4 1.98

850 kcmil

1/2

1-3/4 2.01

1/2

1-3/4 2.19

1000 kcmil 500


3/8

1

2.19

1250 kcmil

1/2

1-3/4 2.46

1300 kcmil

1/2

1-3/4 2.53

1500 kcmil

1/2

1-3/4 2.69

1750 kcmil

1/2

1-3/4 2.90

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

T
45

300
3/8

B
90

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2

600 kcmil

B
B

Figure
Dimensions
(B) (T)
(L)
6.55
2.69 .27 6.14
3.81
5.55
2.69 .26 5.14
2.81
6.70
2.81 .27 6.26
3.84
6.72
2.81 .27 6.26
3.84
6.82
2.88 .27 6.34
3.87
5.82
2.88 .27 5.34
2.87
5.82
2.88 .27 5.34
2.87
6.82
2.88 .27 6.34
3.87
6.89
2.94 .30 6.46
3.91
6.91
2.94 .31 6.48
3.93
7.08
3.00 .33 6.66
4.02
6.09
3.00 .33 5.66
3.02
7.38
3.19 .38 6.99
4.13
7.41
3.19 .39 7.03
4.16
7.48
3.19 .40 7.10
4.22
7.82
3.44 .42 7.40
4.30

Fig. 1

Fig. 2

Fig. 3

Dieless
(# of crimps)

Y644M (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

U36RT (4)
U32ART (4)

Green

U37RT (4)

Orange 23

U38RT (4)

Pink

400

2-7/8

U39RT (4)
P39RT (4)
**

Black

24

2-15/16

P40RT (4)
**

Orange 25

3

Gold

3

P44RT (4)
**

White

27

3-1/16

P45RT (6)
**

Yellow

29

3-1/4

Orange 30

2-1/16

22 or
472

P46RT (6)
**

Green 31

3-5/16

Gray

3-1/2

2/4

2-7/8

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).

For CUSTOMER SERVICE call 1-800-346-4175

Wire
Color Die Strip
Code Index Length

33

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

87

BURNDY
Telecommunications Products
TWO HOLE HYLUG
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
Catalog Number
YAZ48-2N
YAZ48-2N-45
YAZ48-2N-90

Fig
***
#
AWG
MM2
1
2 2000 kcmil 3

B
90

T
45

Stud Stud
Hole Hole Tongue
Size Spacing Width

Figure
Dimensions
(B) (T)
(L)
7.89
1/2 1-3/4 3.10 3.44 .46 7.54
4.40

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adaptor with "U" dies in Y46 HYPRESS.
** P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

88

B
B
L

Fig. 1

Fig. 2

Fig. 3

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length
Brown

34

3-1/2

*** The MM2 conductor sizes listed are the recommendations


for Class 2 conductor.
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TWO HOLE HYLUG
FLEX CONDUCTOR
STANDARD BARREL

COLOR CODE AND


DIE INFORMATION

BEVELED
ENTRY

INSPECTION
WINDOW

TYPES YA-L-2TC, YA-L-2TC-FX,


YAV-L-2TC-FX
COPPER COMPRESSION
TERMINAL

CRIMP

ELECTRO-TIN
PLATED

CABLE
ACCOMMODATION

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

UL Listed 90 C,
600 Volts to 35 kV

B
T

Fig. 1

Catalog Number
YA8CL2TC10
YA8CL2TC10-45
YA8CL2TC10-90
YA8CL2TC14
YA8CL2TC14-45
YA8CL2TC14-90
YA8CL2TC14E1
YA8CL2TC14E1-45
YA8CL2TC14E1-90
YA8CL2TC14E2
YA8CL2TC14E2-45
YA8CL2TC14E2-90
YA8CL2TC38
YA8CL2TC38-45
YA8CL2TC38-90
YAV6C-L2TC10-FX
YAV6C-L2TC10-FX-45
YAV6C-L2TC10-FX-90
YAV6C-L2TC10E2-FX
YAV6C-L2TC10E2-FX-45
YAV6C-L2TC10E2-FX-90
YAV6C-L2TC10E4-FX
YAV6C-L2TC10E4-FX-45
YAV6C-L2TC10E4-FX-90
YAV6C-L2TC10E9-FX
YAV6C-L2TC10E9-FX-45
YAV6C-L2TC10E9-FX-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

# 10

5/8

.41

1/4

5/8

.44

1/4

1

.44

1/4

3/4

.44

3/8

1

.58

# 10

5/8

.44

# 10

3/4

.48

# 10

11/16

.44

# 10

1/2

.48

37/24
#8 WELD

**
10

#8 AWG

61/24
**
#6 WELD
#6 AWG

16

* Use PUADP-1 adaptor with "U" dies in Y46 HYPRESS.


** The MM2 conductor size referenced here is for both Class
2 and Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

Figure
Dimensions
(B) (T)
(L)
1.84
.44 .08 1.83
1.37
1.95
.44 .08 1.94
1.49
2.33
.44 .08 2.32
1.87
2.08
.44 .08 2.07
1.62
2.52
.44. .06 2.46
2.05
1.94
.50 .07 1.86
1.38
2.06
.50 .08 2.06
1.57
2.00
.50 .07 1.95
1.44
1.81
.50 .08 1.77
1.27

Fig. 3

Fig. 2

Conductor
Stud Stud
Hole Hole Tongue
Size Spacing Width

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

MRC840 (1)
MY29-3 (1)
MY29-11 (1)
Y8MRB-1 (1)
Y2MR (1)
Y1MR (1)

W8CVT (1)
W8CRT (1)
X8CRT (1)

W8CVT (1)
W8CRT (1)
X8CRT (1)

U8CRT (1)

Red

49

7/16

MRC840 (1)
MY29-11 (1)
Y2MR (1)
Y644M (1)
Y1MR (1)

W5CVT (1)
W5CRT (1)
X5CRT (1)

W5CVT (1)
W5CRT (1)
X5CRT (1)

U5CRT (1)

Blue

1/2

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

89

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Fig. 1

Conductor
Catalog Number
YAV6C-L2TC14-FX
YAV6C-L2TC14-FX-45
YAV6C-L2TC14-FX-90
YAV6C-L2TC14E2-FX
YAV6C-L2TC14E2-FX-45
YAV6C-L2TC14E2-FX-90
YAV6C-L2TC14E1-FX
YAV6C-L2TC14E1-FX-45
YAV6C-L2TC14E1-FX-90
YAV6C-L2TC516-FX
YAV6C-L2TC516-FX-45
YAV6C-L2TC516-FX-90
YAV6C-L2TC38-FX
YAV6C-L2TC38-FX-45
YAV6C-L2TC38-FX-90
YAV6C-L2NTC-FX
YAV6C-L2NTC-FX-45
YAV6C-L2NTC-FX-90
YAV4C-L2NT10-FX
YAV4C-L2NT10-FX-45
YAV4C-L2NT10-FX-90
YAV4C-L2NT10E1-FX
YAV4C-L2NT10E1-FX-45
YAV4C-L2NT10E1-FX-90
YAV4C-L2TC14-FX
YAV4C-L2TC14-FX-45
YAV4C-L2TC14-FX-90
YAV4C-L2TC14E2-FX
YAV4C-L2TC14E2-FX-45
YAV4C-L2TC14E2-FX-90
YAV4C-L2TC14E1-FX
YAV4C-L2TC14E1-FX-45
YAV4C-L2TC14E1-FX-90
YAV4C-L2TC516-FX
YAV4C-L2TC516-FX-45
YAV4C-L2TC516-FX-90
YAV4C-L2TC38-FX
YAV4C-L2TC38-FX-45
YAV4C-L2TC38-FX-90
YAV4C-L2NTC-FX
YAV4C-L2NTC-FX-45
YAV4C-L2NTC-FX-90
YAV2C-L2TC14-FX
YAV2C-L2TC14-FX-45
YAV2C-L2TC14-FX-90
YAV2C-L2TC14E2-FX
YAV2C-L2TC14E2-FX-45
YAV2C-L2TC14E2-FX-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

5/8

.48

1/4

3/4

.48

1/4

1

.48

61/24
**
#6 WELD
16
#6 AWG

5/16

1

.52

3/8

1

.58

1/2

1-3/4

.83

# 10

5/8

.41

# 10

1

.41

1/4

5/8

.55

1/4

3/4

.55

91/24
105/24

#4 WELD
1/4

1

.55

5/16

1

.55

3/8

1

.58

1/2

1-3/4

.83

1/4

5/8

.68

1/4

3/4

.68

#4 AWG

125/24
150/24
#2 WELD
#2 AWG

35

* Use PUADP-1 adaptor with "U" dies in Y46 HYPRESS.


** The 16 MM2 referenced here is for both Class 2 and Class
5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

90

B
T

Figure
Dimensions
(B) (T)
(L)
2.06
.50 .08 2.02
1.52
2.19
.50 .08 2.15
1.64
2.44
.50 .08 2.40
1.89
2.50
.50 .07 2.45
1.95
2.62
.50 .06 2.56
2.07
3.81
.50 .12 3.67
3.29
1.95
.50 .09 1.94
1.43
2.33
.50 .09 2.31
1.80
2.08
.50 .09 2.06
1.55
2.20
.50 .09 2.19
1.68
2.45
.50 .09 2.44
1.93
2.52
.50 .09 2.50
1.99
2.68
.50 .08 2.64
2.11
3.87
.50 .12 3.91
3.32
2.26
.63 .10 2.22
1.60
2.38
.63 .10 2.34
1.73

Dieless
(# of crimps)

MY29-11 (1)
Y2MR (1)
Y644M
Y1MR (1)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W5CVT (1)
W5CRT (1)
X5CRT (1)

W5CVT (1)
W5CRT (1)
X5CRT (1)

U5CRT (1)

Blue

7/16

W4CVT (1)
W4CRT (1)
X4CRT (1)

W4CVT (1)
W4CRT (1)
X4CRT (1)

U4CRT (1)

Gray

1/2

W2CVT (1)
W2CRT (1)
X2CRT (1)

W2CVT (1)
W2CRT (1)
X2CRT (1)

U2CRT (1)

Brown

10

11/16

MY29-11 (1)
Y2MR (2)
Y644M (1)
Y1MR (2)

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Fig. 1

Conductor
Catalog Number
YAV2C-L2TC14E1-FX
YAV2C-L2TC14E1-FX-45
YAV2C-L2TC14E1-FX-90
YAV2C-L2TC516-FX
YAV2C-L2TC516-FX-45
YAV2C-L2TC516-FX-90
YAV2C-L2TC38-FX
YAV2C-L2TC38-FX-45
YAV2C-L2TC38-FX-90
YAV2C-L2NTC-FX
YAV2C-L2NTC-FX-45
YAV2C-L2NTC-FX-90
YAV1C-L2TC14-FX
YAV1C-L2TC14-FX-45
YAV1C-L2TC14-FX-90
YAV1C-L2TC14E1-FX
YAV1C-L2TC14E1-FX-45
YAV1C-L2TC14E1-FX-90
YAV1C-L2TC14E2-FX
YAV1C-L2TC14E2-FX-45
YAV1C-L2TC14E2-FX-90
YAV1C-L2TC516-FX
YAV1C-L2TC516-FX-45
YAV1C-L2TC516-FX-90
YAV1C-L2TC38-FX
YAV1C-L2TC38-FX-45
YAV1C-L2TC38-FX-90
YAV1C-L2NTC-FX
YAV1C-L2NTC-FX-45
YAV1C-L2NTC-FX-90
YAV25-L2TC14-FX
YAV25-L2TC14-FX-45
YAV25-L2TC14-FX-90
YAV25-L2TC14E2-FX
YAV25-L2TC14E2-FX-45
YAV25-L2TC14E2-FX-90
YAV25-L2TC516E2-FX
YAV25-L2TC516E2-FX-45
YAV25-L2TC516E2-FX-90
YAV25-L2TC516-FX
YAV25-L2TC516-FX-45
YAV25-L2TC516-FX-90
YAV25-L2TC38-FX
YAV25-L2TC38-FX-45
YAV25-L2TC38-FX-90
YAV25-L2TC12E1-FX
YAV25-L2TC12E1-FX-45
YAV25-L2TC12E1-FX-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

150/24
#2 WELD

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

1

.68

5/16

1

.68

35

#2 AWG

3/8

1

.68

1/2

1-3/4

.83

1/4

5/8

.75

1/4

1

.75

1/4

3/4

.75

175/24
225/24

#1 WELD
5/16

1

.75

3/8

1

.75

1/2

1-3/4

.83

#1 AWG

1/4

5/8

.83

1/4

3/4

.83

5/16

3/4

.83

5/16

1

.
.83

3/8

1

.83

1/2

1

.83

275/24
1/0 WELD
1/0 AWG

50

* Use PUADP-1 adaptor with "U" dies in Y46 HYPRESS.


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.

B
T

Figure
Dimensions
(B) (T)
(L)
2.63
.63 .10 2.60
1.98
2.71
.63 .10 2.70
2.04
2.82
.63 .10 2.78
2.17
4.07
.63 .08 3.93
3.34
2.35
.69 .12 2.32
1.64
2.71
.69 .12 2.69
2.00
2.47
.69 .12 2.45
1.76
2.79
.69: .12 2.76
2.08
2.91
.69 .12 2.88
2.20
4.10
.69 .11 4.04
3.38
2.39
.69 .12 2.35
1.66
2.51
.69 .12 2.47
1.79
2.57
.69 .12 2.53
1.85
2.82
.69 .12 2.78
2.10
2.95
.69 .12 2.91
2.23
3.20
.69 .12 3.16
2.48

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

MY29-11 (1)
Y2MR (2)
Y644M (1)
Y1MR (2)

Wire
Color Die Strip
Code Index Length

W2CVT (1)
W2CRT (1)
X2CRT (1)

W2CVT (1)
W2CRT (1)
X2CRT (1)

U2CRT (1)

Brown

10

11/16

W1CVT (1)
W1CRT-1 (1)
X1CRT-1 (1)

W1CVT (1)
W1CRT-1 (1)
X1CRT-1 (1)

U1CRT-1 (1)

Green

11

11/16

W25VT (2)
W25RT (2)
X25RT (2)

W25VT (2)
W25RT (2)
X25RT (2)

U25RT (1)

Pink

12

11/16

MY29-11 (1)
Y644M (1)

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

91

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Fig. 1

Conductor
Catalog Number
YAV25-L2NTC-FX
YAV25-L2NTC-FX-45
YAV25-L2NTC-FX-90
YAV26-L2TC14-FX
YAV26-L2TC14-FX-45
YAV26-L2TC14-FX-90
YAV26-L2TC14E2-FX
YAV26-L2TC14E2-FX-45
YAV26-L2TC14E2-FX-90
YAV26-L2TC516-FX
YAV26-L2TC516-FX-45
YAV26-L2TC516-FX-90
YAV26-L2TC38-FX
YAV26-L2TC38-FX-45
YAV26-L2TC38-FX-90
YAV26-L2TC12E1-FX
YAV26-L2TC12E1-FX-45
YAV26-L2TC12E1-FX-90
YAV26-L2NTC-FX
YAV26-L2NTC-FX-45
YAV26-L2NTC-FX-90
YAV27-L2TC14-FX
YAV27-L2TC14-FX-45
YAV27-L2TC14-FX-90
YAV27-L2TC38-FX
YAV27-L2TC38-FX-45
YAV27-L2TC38-FX-90
YAV27-L2NTC-FX
YAV27-L2NTC-FX-45
YAV27-L2NTC-FX-90
YAV27-L2NTC516-FX
YAV27-L2NTC516-FX-45
YAV27-L2NTC516-FX-90
YAV28-L2TC14E2-FX
YAV28-L2TC14E2-FX-45
YAV28-L2TC14E2-FX-90
YAV28-L2TC14-FX
YAV28-L2TC14-FX-45
YAV28-L2TC14-FX-90
YAV28-L2TC516-FX
YAV28-L2TC516-FX-45
YAV28-L2TC516-FX-90
YAV28-L2TC38-FX
YAV28-L2TC38-FX-45
YAV28-L2TC38-FX-90
YAV28-L2NTC-FX
YAV28-L2NTC-FX-45
YAV28-L2NTC-FX-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG
275/24
1/0 AWG
1/0 WELD

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width

50

1/2

1-3/4

.83

1/4

5/8

.93

1/4

3/4

.93

5/16

1

.93

325/24
2/0 WELD

70

2/0 AWG

3/8

1

.93

1/2

1

.93

1/2

1-3/4

.93

1/4

5/8

1.03

3/8

1

1.03

450/24
3/0 WELD

95

3/0 AWG

1/2

1-3/4

1.03

5/16

1

1.03

1/4

3/4

1.12

1/4

5/8

1.12

5/16

1

1.12

3/8

1

1.12

1/2

1-3/4

1.20

550/24
**
4/0 WELD
120
4/0 AWG

* Use PUADP-1 adaptor with "U" dies in Y46 HYPRESS.


** The 120 MM2 referenced here is for both Class 2 and
Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

92

B
T

Figure
Dimensions
(B) (T)
(L)
4.14
.69 .12 4.10
3.41
2.56
.81 .13 2.49
1.70
2.68
.81 .13 2.61
1.83
2.99
.81 .13 2.93
2.14
3.12
.81 .13 3.05
2.26
3.37
.81 .13 3.30
2.51
4.31
.81 .13 4.24
3.45
2.83
1.00 .14 2.69
1.74
3.35
1.00 .14 3.23
2.30
4.54
1.00 .14 4.42
3.49
3.22
1.00 .14 3.11
2.18
2.91
1.03 .15 2.80
1.86
2.86
1.03 .15 2.74
1.78
3.30
1.03 .15 3.18
2.22
3.43
1.03 .15 3.30
2.34
4.18
1.03 .15 4.05
3.09

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W25VT (2)

W25VT (2)

U25RT (1)

Pink

12

11/16

W26VT (2)
W26RT (2)
X26RT (2)

W26VT (2)
W26RT (2)
X26RT (2)

U26RT (1)

Black

13

13/16

W27VT (2)
W27RT (2)
X27RT (3)

W27VT (2)
W27RT (2)
X27RT (3)

U27RT (1)

Orange

14

1

W28VT (2)
W28RT (2)
X28RT (3)

W28VT (2)
W28RT (2)
X28RT (3)

U28RT (1)

Purple

15

1-1/16

MY29-11 (1)
Y644M (1)

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Fig. 1

Conductor
Fig
***
Catalog Number
#
AWG
MM2
YAV28-L2TC14E2
1
YAV28-L2TC14E2-45
2
YAV28-L2TC14E2-90
3
YAV28-L2NT38-FX
1
YAV28-L2NT38-FX-45
2
YAV28-L2NT38-FX-90
3
550/24
YAV28-LTC12E1-FX
1
**
YAV28-LTC12E1-FX-45
2 4/0 WELD
YAV28-LTC12E1-FX-90
3
120
YAV28-L2TC12-FX
1
4/0 AWG
YAV28-L2TC12-FX-45
2
YAV28-L2TC12-FX-90
3
YAV28-L2NTC-FX
1
YAV28-L2NTC-FX-45
2
YAV28-L2NTC-FX-90
3
YAV29-L2TC14E2-FX
1
YAV29-L2TC14E2-FX-45 2
YAV29-L2TC14E2-FX-90 3
YAV29-L2TC14-FX
1
YAV29-L2TC14-FX-45
2
YAV29-L2TC14-FX-90
3
YAV29-L2TC516-FX
1
YAV29-L2TC516-FX-45
2
YAV29-L2TC516-FX-90
3
YAV29-L2TC38-FX
1
YAV29-L2TC38-FX-45
2
550/24
YAV29-L2TC38-FX-90
3

YAV29-L2NTC-FX
1 4/0 WELD
YAV29-L2NTC-FX-45
2
YAV29-L2NTC-FX-90
3
YAV29-L2NT38-FX
1
YAV29-L2NT38-FX-45
2
YAV29-L2NT38-FX-90
3
YAV29-LTC12E1-FX
1
YAV29-LTC12E1-FX-45
2
YAV29-LTC12E1-FX-90
3
YAV29-L2TC12-FX
1
YAV29-L2TC12-FX-45
2
YAV29-L2TC12-FX-90
3
YA30-L2TC38-FX
1
YA30-L2TC38-FX-45
2
YA30-L2TC38-FX-90
3
YA30-L2TC12-FX
1 250 FLEX
YA30-L2TC12-FX-45
2 CLASS G 259 STR
YA30-L2TC12-FX-90
3 CLASS H 427 STR
YA30-L2NTC-FX
1
YA30-L2NTC-FX-45
2
YA30-L2NTC-FX-90
3

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

3/4

1.14

3/8

1

.94

1/2

1

1.14

1/2

1-1/4

1.14

1/2

1-3/4

1.14

1/4

3/4

1.12

1/4

5/8

1.12

5/16

1

1.12

3/8

1

1.12

1/2

1-3/4

1.20

3/8

1

.94

1/2

1

1.14

1/2

1-1/4

1.14

3/8

1

1.20

1/2

1-1/4

1.20

1/2

1-3/4

1.20

* Use PUADP-1 adaptor with "U" dies in Y46 HYPRESS.


** The 120 MM2 referenced here is for both Class 2 and
Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

B
T

Figure
Dimensions
(B) (T)
(L)
2.99
1.03 .15 2.87
1.90
3.44
1.03 .15 3.36
2.36
3.68
1.03 .15 3.55
2.59
3.93
1.03 .15 3.80
2.84
4.62
1.03 .15 4.49
3.53
2.91
1.03 .16 2.80
1.86
2.86
1.03 .16 2.74
1.78
3.30
1.03 .16 3.18
2.22
3.43
1.03 .16 3.30
2.34
4.18
1.03 .16 4.05
3.09
3.44
1.03 .16 3.36
2.36
3.68
1.03 .16 3.55
2.59
3.93
1.03 .16 3.80
2.84
3.45
1.03 .16 3.36
2.37
3.95
1.03 .16 3.86
2.87
4.63
1.03 .16 4.55
3.56

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

MY29-11 (1)
Y644M (1)

W28VT (2)
W28RT (2)
X28RT (3)

W28VT (2)
W28RT (2)
X28RT (3)

U28RT (1)

Purple

15

1-1/16

Y644M (1)

W29VT (2)
X29RT (4)

W29VT (2)
W29RT (2)
X29RT (4)

U29RT (1)

Yellow

16

1-1/16

Y644M (1)

W29VT (2)
X29RT (4)

W29VT (2)
W29RT (2)
X29RT (4)

U29RT (1)

Yellow

16

1-1/16

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

93

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

Catalog Number
YA31-L2TC38-FX
YA31-L2TC38-FX-45
YA31-L2TC38-FX-90
YA31-L2TC12-FX
YA31-L2TC12-FX-45
YA31-L2TC12-FX-90
YA31-L2NTC-FX
YA31-L2NTC-FX-45
YA31-L2NTC-FX-90
YA31-L2NTC38-FX
YA31-L2NTC38-FX-45
YA31-L2NTC38-FX-90
YA32-L2TC38-FX
YA32-L2TC38-FX-45
YA32-L2TC38-FX-90
YA32-L2NTC-FX
YA32-L2NTC-FX-45
YA32-L2NTC-FX-90
YA34-L2TC38-FX
YA34-L2TC38-FX-45
YA34-L2TC38-FX-90
YA34-L2TC12-FX
YA34-L2TC12-FX-45
YA34-L2TC12-FX-90
YA34-L2NTC-FX
YA34-L2NTC-FX-45
YA34-L2NTC-FX-90
YA34-L2TC516-FX
YA34-L2TC516-FX-45
YA34-L2TC516-FX-90
YA34-L2NT38-FX
YA34-L2NT38-FX-45
YA34-L2NT38-FX-90
YA34-L2NTC38-FX
YA34-L2NTC38-FX-45
YA34-L2NTC38-FX-90
YA36-L2TC38-FX
YA36-L2TC38-FX-45
YA36-L2TC38-FX-90
YA36-L2NTC-FX
YA36-L2NTC-FX-45
YA36-L2NTC-FX-90
YA38-L2TC38-FX
YA38-L2TC38-FX-45
YA38-L2TC38-FX-90
YA38-L2TC12-FX
YA38-L2TC12-FX-45
YA38-L2TC12-FX-90

AWG

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8

250 FLEX

1.29

150
1/2 1-3/4 1.29

3/8 1-3/4 1.29

3/8

775/24

1

1.38

185
313.1 kcmil

1/2 1-3/4 1.38

3/8

1

1.52

1/2 1-1/4 1.52


373.7 kcmil
1/2 1-3/4 1.52
925/24

240

(350 MCM NOM)

5/16

1

1.55

3/8

1

.96

3/8 1-3/4 1.55

3/8

1100/24

1

1.72

444.4 kcmil

535.3 kcmil
1325/24 300
(500 MCM NOM)

1/2 1-3/4 1.72

3/8

1

1.81

1/2 1-1/4 1.81

* Use PUADP-1 adaptor with "U" dies in Y46 HYPRESS.


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.

94

1

1/2 1-1/4 1.29

637/24

Fig. 1

Conductor
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

B
T

Figure
Dimensions
(B) (T)
(L)
3.51
1.06 .18 3.43
2.41
4.01
1.06 .18 3.93
2.91
4.70
1.06 .18 4.62
3.60
4.26
1.06 .18 4.18
3.16
3.69
1.19 .19 3.59
2.45
4.88
1.19 .19 4.78
3.64
3.88
1.27 .23 3.81
2.54
4.38
1.27 .23 4.31
3.04
5.06
1.27 .23 5.00
3.73
3.75
1.27 .23 3.69
2.42
3.88
1.27 .23 3.81
2.54
4.63
1.27 .23 4.56
3.29
4.24
1.38 .27 4.21
2.81
5.24
1.38 .27 5.21
3.81
4.35
1.45 .27 4.30
2.84
4.67
1.45 .27 4.61
3.16

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W30VT (2)

W30VT (2)
W30RT (2)

U30RT (2)

White 17

1-1/8

W31VT (2)

W31VT (2)
W31RT (2)

U31RT (2)

Red

18

1-1/4

W32VT (2)

W32VT (2)
W32RT (2)

U32RT (2)

Blue

19 1-5/16

U34RT (2)

U38XRT (2)

Y644M (1)

Brown 20 1-7/16

Pink

L99 1-7/16

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
(Continued)

AWG

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2 1-3/4 1.81

535.3 kcmil
1325/24

5/16

1

1.84

300
3/8

(500 MCM NOM)

1

1.63

1/2 1-3/4 1.63

600 kcmil

1/2 1-3/4 1.91

1/2 1-3/4 1.95


646 kcmil
400

3/8

1

1.98

1600/24
1/2 1-3/4 1.63

3/8

1

2.19

1/2 1-3/4 2.19

5/8 1-1/2 2.19


777.7 kcmil
1925/24

500

1/2 1-1/4 2.19

(750 MCM NOM)


1/2 1-1/2 2.19

3/8

1

1.63

1/2 1-3/4 1.63

* Use PUADP-1 adaptor with "U" dies in Y46 HYPRESS.


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.

Fig. 1

Conductor
Fig
Catalog Number
#
YA38-L2NTC-FX
1
YA38-L2NTC-FX-45
2
YA38-L2NTC-FX-90
3
YA38-L2TC516-FX
1
YA38-L2TC516-FX-45 2
YA38-L2TC516-FX-90 3
YA38-L2NT38-FX
1
YA38-L2NT38-FX-45
2
YA38-L2NT38-FX-90
3
YA38-L2NNT-FX
1
YA38-L2NNT-FX-45
2
YA38-L2NNT-FX-90
3
YA39-L2NTC-FX
1
YA39-L2NTC-FX-45
2
YA39-L2NTC-FX-90
3
YA40-L2NTC-FX
1
YA40-L2NTC-FX-45
2
YA40-L2NTC-FX-90
3
YA40-L2TC38-FX
1
YA40-L2TC38-FX-45
2
YA40-L2TC38-FX-90
3
YA40-L2NNT-FX
1
YA40-L2NNT-FX-45
2
YA40-L2NNT-FX-90
3
YA44-L2TC38-FX
1
YA44-L2TC38-FX-45
2
YA44-L2TC38-FX-90
3
YA44-L2NTC-FX
1
YA44-L2NTC-FX-45
2
YA44-L2NTC-FX-90
3
YA44-L2TC58-FX
1
YA44-L2TC58-FX-45
2
YA44-L2TC58-FX-90
3
YA44-L2TC12-FX
1
YA44-L2TC12-FX-45
2
YA44-L2TC12-FX-90
3
YA44-L2TC12E3-FX
1
YA44-L2TC12E3-FX-45 2
YA44-L2TC12E3-FX-90 3
YA44-L2NT38-FX
1
YA44-L2NT38-FX-45
2
YA44-L2NT38-FX-90
3
YA44-L2NNT-FX
1
YA44-L2NNT-FX-45
2
YA44-L2NNT-FX-90
3

B
T

Figure
Dimensions
(B) (T)
(L)
5.35
1.45 .27 5.30
3.84
4.04
1.45 .27 3.98
2.53
4.35
1.45 .27 4.30
2.84
5.35
1.45 .27 5.30
3.84
5.36
1.42 .27 5.31
3.87
5.38
1.42 .30 5.38
3.91
4.28
1.42 .30 4.20
2.72
5.38
1.42 .30 5.38
3.91
4.74
1.65 .33 4.71
3.02
5.74
1.65 .33 5.71
4.02
5.55
1.65 .33 5.52
3.83
5.05
1.65 .33 5.02
3.33
5.30
1.65 .33 5.27
3.58
4.74
1.65 .33 4.71
3.02
5.74
1.65 .33 5.71
4.02

Dieless
(# of crimps)

Fig. 2

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

U38XRT (2)

Pink

L99 1-7/16

U38RT (2)

Purple 23

U39RT (2)

Black

U44XRT (2)

Yellow L115 1-5/8

1-3/8

24 1-5/16

Y644M (1)

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

95

BURNDY
Telecommunications Products
TWO HOLE HYLUG
FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED

BEVELED
ENTRY

DIE AND COLOR


CODE INFORMATION

NO INSPECTION
WINDOW
CRIMPS

TYPE YAG-L-2TC-LD
LEAD
PLATED

COPPER COMPRESSION
TERMINAL

CABLE
ACCOMMODATION

UL Listed 90 C,
600 Volts to 35 kV
B

B
T

90

45
L

Fig. 2

Fig. 3

Fig. 1

Conductor
Catalog Number
YAG8CL-2TC14-LD
YAG8CL-2TC14-LD-45
YAG8CL-2TC14-LD-90
YAG8CL-2TC38-LD
YAG8CL-2TC38-LD-45
YAG8CL-2TC38-LD-90
YAG8CL-2TC10-LD
YAG8CL-2TC10-LD-45
YAG8CL-2TC10-LD-90
YAG8CL-2TC14E1-LD
YAG8CL-2TC14E1-LD-45
YAG8CL-2TC14E1-LD-90
YAG8CL-2TC14E2-LD
YAG8CL-2TC14E2-LD-45
YAG8CL-2TC14E2-LD-90
YAG6CL-2TC10-LD
YAG6CL-2TC10-LD-45
YAG6CL-2TC10-LD-90
YAG6CL-2TC10E2-LD
YAG6CL-2TC10E2-LD-45
YAG6CL-2TC10E2-LD-90
YAG6CL-2TC10E4-LD
YAG6CL-2TC10E4-LD-45
YAG6CL-2TC10E4-LD-90
YAG6CL-2TC10E-LD
YAG6CL-2TC10E-LD-45
YAG6CL-2TC10E-LD-90
YAG6CL-2TC14-LD
YAG6CL-2TC14-LD-45
YAG6CL-2TC14-LD-90
YAG6CL-2TC14E1-LD
YAG6CL-2TC14E1-LD-45
YAG6CL-2TC14E1-LD-90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

5/8

.41

3/8

1

.57

# 10

5/8

.41

1/4

1

.44

1/4

3/4

.44

# 10

5/8

.44

# 10

3/4

.48

# 10

11/16

.44

#8 WELD
37/24

**
10

#8 AWG

#6 WELD
61/24

**
16

#6 AWG

# 10

1/2

.48

1/4

5/8

.48

1/4

1

.48

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** The MM2 conductor size referenced here is for both Class
2 and Class 5 conductor.

96

Figure
Dimensions
(B) (T)
(L)
1.95 
.44 .08 1.94
1.00
2.52
.44 .06 2.46
2.05
1.84
.44 .08 1.83
1.37
2.33
.44 .08 2.32
1.87
2.08
.44 .08 2.07
1.62
1.94
.50 .07 1.86
1.38
2.06
.50 .08 2.02
1.57
2.00
.50 .07 1.95
1.44
1.81
.50 .08 1.77
1.27
2.06
.50 .08 2.02
1.52
2.44
.50 .08 2.40
1.89

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
W8CVT
W8CVT
U8CRT

Wire
Color Die Strip
Code Index Length
Red 49
1/2

MRC840 (1)
MY29-3 (1)
MY29-11 (1)
Y8MRB-1 (1)
Y2MR (1)
Y1MR (1)

W8CVT (1)
W8CRT (1)
X8CRT (1)

W8CVT (1)
W8CRT (1)
X8CRT (1)

U8CRT (1)

Red

49

7/16

MY29-11 (1)
Y2MR (1)
Y644M (1)
Y1MR (1)

W5CVT (1)
W5CRT (1)
X5CRT (1)

W5CVT (1)
W5CRT (1)
X5CRT (1)

U5CRT (1)

Blue

1/2

*** The MM2 conductor sizes listed are the recommendations


for Class 5 conductor.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
YAG6CL-2TC14E2-LD
YAG6CL-2TC14E2-LD-45
YAG6CL-2TC14E2-LD-90
YAG6CL-2TC516-LD
YAG6CL-2TC516-LD-45
YAG6CL-2TC516-LD-90
YAG6CL-2TC38-LD
YAG6CL-2TC38-LD-45
YAG6CL-2TC38-LD-90
YAG6CL-2NTC-LD
YAG6CL-2NTC-LD-45
YAG6CL-2NTC-LD-90
YAG4CL-2NT10-LD
YAG4CL-2NT10-LD-45
YAG4CL-2NT10-LD-90
YAG4CL-2NT10E1-LD
YAG4CL-2NT10E1-LD-45
YAG4CL-2NT10E1-LD-90
YAG4CL-2TC14-LD
YAG4CL-2TC14-LD-45
YAG4CL-2TC14-LD-90
YAG4CL-2TC14E2-LD
YAG4CL-2TC14E2-LD-45
YAG4CL-2TC14E2-LD-90
YAG4CL-2TC14E1-LD
YAG4CL-2TC14E1-LD-45
YAG4CL-2TC14E1-LD-90
YAG4CL-2TC38-LD
YAG4CL-2TC38-LD-45
YAG4CL-2TC38-LD-90
YAG4CL-2TC516-LD
YAG4CL-2TC516-LD-45
YAG4CL-2TC516-LD-90
YAG4CL-2NTC-LD
YAG4CL-2NTC-LD-45
YAG4CL-2NTC-LD-90
YAG2CL-2TC14-LD
YAG2CL-2TC14-LD-45
YAG2CL-2TC14-LD-90
YAG2CL-2TC14E1-LD
YAG2CL-2TC14E1-LD-45
YAG2CL-2TC14E1-LD-90
YAG2CL-2TC14E2-LD
YAG2CL-2TC14E2-LD-45
YAG2CL-2TC14E2-LD-90
YAG2CL-2TC38-LD
YAG2CL-2TC38-LD-45
YAG2CL-2TC38-LD-90

AWG

***
MM2

#6 WELD
61/24

**
16

#6 AWG

45

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

3/4

.48

5/16

1

.52

3/8

1

.58

1/2

1-3/4

.83

# 10

5/8

.41

# 10

1

.41

1/4

5/8

.55

1/4

3/4

.55

#4 WELD
91/24
105/24

1/4

1

.55

3/8

1

.58

5/16

1

.55
.

1/2

1-3/4

.83

1/4

5/8

.68

1/4

1

.68

#4 AWG

#2 WELD
125/24
150/24

35
1/4

3/4

.68

3/8

1

.68

#2 AWG

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** The 16 MM2 referenced here is for both Class 2 and Class
5 conductor.

90

Fig. 1

Fig. 2

Fig. 3

Conductor
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

B
T

Figure
Dimensions
(B) (T)
(L)
2.18
.50 .08 2.15
1.64
2.50
.50 .07 2.45
1.95
2.62
.50 .06 2.56
2.07
3.81
.50 .12 3.67
3.29
1.99
.50 .09 1.97
1.43
2.37
.50 .09 2.34
1.80
2.11
.50 .09 2.09
1.55
2.24
.50 .09 2.22
1.68
2.49
.50 .09 2.47
1.93
2.68
.50 .08 2.64
2.11
2.56
.50 .09 2.53
1.99
3.87
.50 .12 3.91
3.32
2.28
.63 .10 2.23
1.60
2.63
.63 .10 2.60
1.98
2.40
.63 .10 2.36
1.73
2.84
.63 .10 2.79
2.17

Dieless
(# of crimps)

MY29-11 (1)
Y2MR (1)
Y644M (1)
Y1MR (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W5CVT (1)
W5CRT (1)
X5CRT (1)

W5CVT (1)
W5CRT (1)
X5CRT (1)

U5CRT (1)

Blue

1/2

W4CVT (1)
W4CRT (1)
X4CRT (1)

W4CVT (1)
W4CRT (1)
X4CRT (1)

U4CRT (1)

Gray

1/2

W2CVT (1)
W2CRT (1)
X2CRT (1)

W2CVT (1)
W2CRT (1)
X2CRT (1)

U2CRT (1)

Brown

10

11/16

MY29-11 (1)
Y2MR (2)
Y644M (1)
Y1MR (2)

*** The MM2 conductor sizes listed are the recommendations


for Class 5 conductor.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

97

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

AWG
#2 WELD
125/24
150/24
#2 AWG

***
MM2

45

Stud Stud
Hole Hole Tongue
Size Spacing Width
5/16

1

.68

1/2

1-3/4

.83

1/4

5/8

.75

1/4

3/4

.75

1/4

1

.75

35

#1 WELD
175/24
225/24

5/16

1

.75

3/8

1

.75

1/2

1-3/4

.83

1/4

5/8

.83

#1 AWG

1/4

3/4

.83

5/16

3/4

.83

5/16

1

.83

3/8

1

.83

1/2

1-3/4

.83

1/2

1

.83

1/4

5/8

.93

1/0 WELD
275/24

50

1/0 AWG

2/0 WELD
325/24
2/0 AWG

70

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

98

90

Fig. 1

Fig. 2

Fig. 3

Conductor
Fig
Catalog Number
#
YAG2CL-2TC516-LD
1
YAG2CL-2TC516-LD-45
2
YAG2CL-2TC516-LD-90
3
YAG2CL-2NTC-LD
1
YAG2CL-2NTC-LD-45
2
YAG2CL-2NTC-LD-90
3
YAG1CL-2TC14-LD
1
YAG1CL-2TC14-LD-45
2
YAG1CL-2TC14-LD-90
3
YAG1CL-2TC14E2-LD
1
YAG1CL-2TC14E2-LD-45 2
YAG1CL-2TC14E2-LD-90 3
YAG1CL-2TC14E1-LD
1
YAG1CL-2TC14E1-LD-45 2
YAG1CL-2TC14E1-LD-90 3
YAG1CL-2TC516-LD
1
YAG1CL-2TC516-LD-45
2
YAG1CL-2TC516-LD-90
3
YAG1CL-2TC38-LD
1
YAG1CL-2TC38-LD-45
2
YAG1CL-2TC38-LD-90
3
YAG1CL-2NTC-LD
1
YAG1CL-2NTC-LD-45
2
YAG1CL-2NTC-LD-90
3
YAG25L-2TC14-LD
1
YAG25L-2TC14-LD-45
2
YAG25L-2TC14-LD-90
3
YAG25L-2TC14E2-LD
1
YAG25L-2TC14E2-LD-45
2
YAG25L-2TC14E2-LD-90
3
YAG25L-2TC516E2-LD
1
YAG25L-2TC516E2-LD-45 2
YAG25L-2TC516E2-LD-90 3
YAG25L-2TC516-LD
1
YAG25L-2TC516-LD-45
2
YAG25L-2TC516-LD-90
3
YAG25L-2TC38-LD
1
YAG25L-2TC38-LD-45
2
YAG25L-2TC38-LD-90
3
YAG25L-2NTC-LD
1
YAG25L-2NTC-LD-45
2
YAG25L-2NTC-LD-90
3
YAG25L-2TC12E1-LD
1
YAG25L-2TC12E1-LD-45
2
YAG25L-2TC12E1-LD-90
3
YAG26L-2TC14-LD
1
YAG26L-2TC14-LD-45
2
YAG26L-2TC14-LD-90
3

B
T

Figure
Dimensions
(B) (T)
(L)
2.71
.63 .10 2.67
2.04
4.03
.63 .08 3.94
3.34
2.37
.69 .12 2.33
1.64
2.49
.69 .12 2.46
1.76
2.73
.69 .12 2.70
2.00
2.81
.69 .12 2.77
2.08
2.93
.69 .12 2.90
2.20
4.12
.69 .11 4.06
3.38
2.41
.69 .12 2.36
1.66
2.53
.69 .12 2.49
1.79
2.60
.69 .12 2.55
1.85
2.85
.69 .12 2.80
2.10
2.97
.69 .12 2.92
2.23
4.16
.69 .12 4.11
3.41
3.22
.69 .12 3.17
2.48
2.58
.81 .13 2.51
1.70

Dieless
(# of crimps)

MY29-11 (1)
Y2MR (2)
Y644M (1)
Y1MR (2)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W2CVT (1)
W2CRT (1)
X2CRT (1)

W2CVT (1)
W2CRT (1)
X2CRT (1)

U2CRT (1)

Brown

10

11/16

W1CVT (1)
W1CRT-1 (1)
X1CRT-1 (1)

W1CVT (1)
W1CRT-1 (1)
X1CRT-1 (1)

U1CRT-1 (1)

Green

11

11/16

W25VT (2)
W25RT (2)
X25RT (2)

W25VT (2)
W25RT (2)
X25RT (2)

U25RT (1)

Pink

12

11/16

W26RT (2)
W26VT (2)
X26RT (2)

W26RT (2)
W26VT (2)
X26RT (2)

U26RT (1)

Black

13

13/16

MY29-11 (1)
Y644M (1)

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
YAG26L-2TC14E2-LD
YAG26L-2TC14E2-LD-45
YAG26L-2TC14E2-LD-90
YAG26L-2TC516-LD
YAG26L-2TC516-LD-45
YAG26L-2TC516-LD-90
YAG26L-2TC38-LD
YAG26L-2TC38-LD-45
YAG26L-2TC38-LD-90
YAG26L-2NTC-LD
YAG26L-2NTC-LD-45
YAG26L-2NTC-LD-90
YAG27L-2TC14-LD
YAG27L-2TC14-LD-45
YAG27L-2TC14-LD-90
YAG27L-2TC14E2-LD
YAG27L-2TC14E2-LD-45
YAG27L-2TC14E2-LD-90
YAG27L-2TC516-LD
YAG27L-2TC516-LD-45
YAG27L-2TC516-LD-90
YAG27L-2TC38-LD
YAG27L-2TC38-LD-45
YAG27L-2TC38-LD-90
YAG27L-2NTC-LD
YAG27L-2NTC-LD-45
YAG27L-2NTC-LD-90
YAG28L-2TC14-LD
YAG28L-2TC14-LD-45
YAG28L-2TC14-LD-90
YAG28L-2TC14E2-LD
YAG28L-2TC14E2-LD-45
YAG28L-2TC14E2-LD-90
YAG28L-2TC516-LD
YAG28L-2TC516-LD-45
YAG28L-2TC516-LD-90
YAG28L-2TC38-LD
YAG28L-2TC38-LD-45
YAG28L-2TC38-LD-90
YAG28L-2NT38-LD
YAG28L-2NT38-LD-45
YAG28L-2NT38-LD-90
YAG28L-2TC12E1-LD
YAG28L-2TC12E1-LD-45
YAG28L-2TC12E1-LD-90
YAG28L-2TC12-LD
YAG28L-2TC12-LD-45
YAG28L-2TC12-LD-90

AWG

***
MM2

2/0 WELD
325/24

45

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4

3/4

.93

5/16

1

.93

70

2/0 AWG

3/8

1

.93

1/2

1-3/4

.93

1/4

5/8

1.03

1/4

3/4

1.03

5/16

1

1.03

3/8

1

1.03

3/0 WELD
450/24

95

3/0 AWG

1/2

1-3/4

1.03

1/4

5/8

1.14

1/4

3/4

1.14

5/16

1

1.14

3/8

1

1.14

3/8

1

.94

1/2

1

1.14

1/2

1-1/4

1.14

4/0 WELD
**
550/24
120
4/0 AWG

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** The 120 MM2 referenced here is for both Class 2 and
Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

90

Fig. 1

Fig. 2

Fig. 3

Conductor
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

B
T

Figure
Dimensions
(B) (T)
(L)
2.71
.81 .13 2.63
1.83
3.02
.81 .13 2.94
2.14
3.14
.81 .13 3.39
3.32
4.33
.81 .13 4.26
3.45
2.81
1.00 .14 2.67
1.74
2.94
1.00 .14 2.82
1.86
3.25
1.00 .14 3.13
2.18
3.38
1.00 .14 3.25
2.30
4.56
1.00 .14 4.44
3.49
2.90
1.03 .15 2.76
1.78
3.02
1.03 .15 2.89
1.90
3.33
1.03 .15 3.20
2.22
3.46
1.03 .15 3.33
2.34
3.48
1.03 .17 3.38
2.36
3.71
1.03 .17 3.58
2.59
3.96
1.03 .17 3.83
2.84

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

W26RT (2)
W26VT (2)
X26RT (2)

W26RT (2)
W26VT (2)
X26RT (2)

U26RT (1)

W27VT (2)
W27RT (2)
X27RT (3)

W27VT (2)
W27RT (2)
X27RT (3)

W28VT (2)
W28RT (2)
X28RT (3)

W28VT (2)
W28RT (2)
X28RT (3)

Wire
Color Die Strip
Code Index Length

Black

13

13/16

U27RT (1)

Orange 14

1.00

U28RT (1)

Purple

MY29-11 (1)
Y644M (1)

15

1-1/16

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

99

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
YAG28L-2NTC-LD
YAG28L-2NTC-LD-45
YAG28L-2NTC-LD-90
YAG29L-2TC14-LD
YAG29L-2TC14-LD-45
YAG29L-2TC14-LD-90
YAG29L-2TC14E2-LD
YAG29L-2TC14E2-LD-45
YAG29L-2TC14E2-LD-90
YAG29L-2TC516-LD
YAG29L-2TC516-LD-45
YAG29L-2TC516-LD-90
YAG29L-2TC38-LD
YAG29L-2TC38-LD-45
YAG29L-2TC38-LD-90
YAG29L-2NT38-LD
YAG29L-2NT38-LD-45
YAG29L-2NT38-LD-90
YAG29L-2TC12E1-LD
YAG29L-2TC12E1-LD-45
YAG29L-2TC12E1-LD-90
YAG29L-2TC12-LD
YAG29L-2TC12-LD-45
YAG29L-2TC12-LD-90
YAG29L-2NTC-LD
YAG29L-2NTC-LD-45
YAG29L-2NTC-LD-90
YAG30L-2TC38-LD
YAG30L-2TC38-LD-45
YAG30L-2TC38-LD-90
YAG30L-2TC12-LD
YAG30L-2TC12-LD-45
YAG30L-2TC12-LD-90
YAG30L-2NTC-LD
YAG30L-2NTC-LD-45
YAG30L-2NTC-LD-90
YAG31L-2TC38-LD
YAG31L-2TC38-LD-45
YAG31L-2TC38-LD-90
YAG31L-2NTC38-LD
YAG31L-2NTC38-LD-45
YAG31L-2NTC38-LD-90
YAG31L-2TC12-LD
YAG31L-2TC12-LD-45
YAG31L-2TC12-LD-90
YAG31L-2NTC-LD
YAG31L-2NTC-LD-45
YAG31L-2NTC-LD-90

45

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2

1-3/4

1.14

1/4

5/8

1.14

1/4

3/4

1.14

5/16

1

1.14

3/8

1

1.14

3/8

1

.94

1/2

1

1.14

1/2

1-1/4

1.14

1/2

1-3/4

1.14

3/8

1

1.20

1/2

1-1/4

1.20

1/2

1-3/4

1.20

3/8

1

1.29

3/8

1-3/4

1.29

1/2

1-1/4

1.29

1/2

1-3/4

1.29

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** The 120 MM2 referenced here is for both Class 2 and
Class 5 conductor.

100

90

Fig. 1

Fig. 2

Fig. 3

Conductor
Fig
***
#
AWG
MM2
1 4/0 WELD
**
2
550/24
120
3
4/0 AWG
1
2
3
1
2
3
1
2
3
1
2 4/0 WELD
3

1
550/24
2
3
1
2
3
1
2
3
1
2
3
1
2
3
250 kcmil
1
2 CLASS G 259 STR
3
1 CLASS H 427 STR
2
3
2
2
2
1
250 WELD
2
3
637/24
150
1
2
CLASS I,K,M
3
1
2
3

B
T

Figure
Dimensions
(B) (T)
(L)
4.65
1.03 .15 4.51
3.53
2.90
1.03 .16 2.76
1.78
3.02
1.03 .16 2.89
1.90
3.33
1.03 .16 3.20
2.22
3.46
1.03 .16 3.33
2.34
3.48
1.03 .16 3.38
2.36
3.71
1.03 .16 3.58
2.59
3.96
1.03 .16 3.83
2.84
4.65
1.03 .16 4.51
3.53
3.48
1.03 .16 3.38
2.37
3.98
1.03 .16 3.88
2.87
4.67
1.03 .16 4.57
3.56
3.54
1.06 .18 3.46
2.41
4.30
1.06 .18 4.20
3.20
4.04
1.06 .18 3.96
2.91
4.73
1.06 .18 4.64
3.60

Dieless
(# of crimps)

MY29-11(1)
Y644M (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
W28VT (2)
W28VT (2)
W28RT (2)
W28RT (2)
U28RT (1)
X28RT (3)
X28RT (3)

Wire
Color Die Strip
Code Index Length
Purple

15

1-1/16

W29VT (2)
X29RT (4)

W29VT (2)
W29RT (2)
X29RT (4)

U29RT (1)

Yellow

16

1-1/16

W29VT (2)
X29RT (4)

W29VT (2)
W29RT (2)
X29RT (4)

U29RT (1)

Yellow

16

1-1/16

W30VT (2)

W30VT (2)
W30RT (2)

U30RT (2)

White

17

1-1/8

Y644M (1)

*** The MM2 conductor sizes listed are the recommendations


for Class 5 conductor.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
YAG32L-2TC38-LD
YAG32L-2TC38-LD-45
YAG32L-2TC38-LD-90
YAG32L-2NTC-LD
YAG32L-2NTC-LD-45
YAG32L-2NTC-LD-90
YAG34L-2TC516-LD
YAG34L-2TC516-LD-45
YAG34L-2TC516-LD-90
YAG34L-2TC38-LD
YAG34L-2TC38-LD-45
YAG34L-2TC38-LD-90
YAG34L-2NT38-LD
YAG34L-2NT38-LD-45
YAG34L-2NT38-LD-90
YAG34L-2TC12-LD
YAG34L-2TC12-LD-45
YAG34L-2TC12-LD-90
YAG34L-2NTC-LD
YAG34L-2NTC-LD-45
YAG34L-2NTC-LD-90
YAG36L-2TC38-LD
YAG36L-2TC38-LD-45
YAG36L-2TC38-LD-90
YAG36L-2NTC-LD
YAG36L-2NTC-LD-45
YAG36L-2NTC-LD-90
YAG38L-2TC516-LD
YAG38L-2TC516-LD-45
YAG38L-2TC516-LD-90
YAG38L-2NT38-LD
YAG38L-2NT38-LD-45
YAG38L-2NT38-LD-90
YAG38L-2TC38-LD
YAG38L-2TC38-LD-45
YAG38L-2TC38-LD-90
YAG38L-2TC12-LD
YAG38L-2TC12-LD-45
YAG38L-2TC12-LD-90
YAG38L-2NTC-LD
YAG38L-2NTC-LD-45
YAG38L-2NTC-LD-90
YAG39L-2NTC-LD
YAG39L-2NTC-LD-45
YAG39L-2NTC-LD-90
YAG40L-2TC38-LD
YAG40L-2TC38-LD-45
YAG40L-2TC38-LD-90

AWG

***
MM2

45

Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8

775/24

1

1.40

185
313.1 kcmil

1/2

1-3/4

1.40

5/16

1

1.55

3/8

1

1.55

3/8

1-3/4

.96

1/2

1-1/4

1.55

1/2

1-3/4

1.55

3/8

1

1.73

1/2

1-3/4

1.73

5/16

1

1.82

3/8

1

1.63

3/8

1

1.82

1/2

1-1/4

1.82

1/2

1-3/4

1.82

373.7 kcmil
925/24

240

350 kcmil CLASS I

1100/24

444.4 kcmil

535.3 kcmil
1325/24

300

500 kcmil CLASS I

600 kcmil

1/2

1-3/4

1.90

646 kcmil
1600/24

400

3/8

1

1.98

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

90

Fig. 1

Fig. 2

Fig. 3

Conductor
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

B
T

Figure
Dimensions
(B) (T)
(L)
3.73
1.19 .19 3.62
2.45
4.91
1.19 .19 4.81
3.64
3.79
1.27 .23 3.72
2.42
3.92
1.27 .23 3.84
2.54
4.67
1.27 .23 4.59
3.29
4.42
1.27 .23 3.34
3.04
5.11
1.27 .23 5.03
3.73
4.28
1.38 .27 4.24
2.81
5.28
1.38 .27 5.24
3.81
4.09
1.45 .27 4.02
2.53
4.40
1.45 .27 4.33
2.84
4.28
1.45 .27 4.24
2.81
4.72
1.45 .27 4.64
3.16
5.28
1.45 .27 5.24
3.81
5.29
1.19 .27 5.26
3.87
4.33
1.42 .30 4.23
2.72

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Y644M (1)

Wire
Color Die Strip
Code Index Length

W31VT (2)

W31VT (2)
W31RT (2)

U31RT (2)

Red

18

1-1/4

W32VT (2)

W32VT (2)
W32RT (2)

U32RT (2)

Blue

19

1-5/16

U34RT (2)

Brown

20

1-3/8

U38XRT (2)

Pink

20

1-3/8

U38RT (2)

Purple 400

1-3/8

U39RT (2)

Black

1-5/16

24

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

101

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
STANDARD BARREL
LEAD PLATED
(Continued)

Catalog Number
YAG40L-2NNT-LD
YAG40L-2NNT-LD-45
YAG40L-2NNT-LD-90
YAG40L-2NTC-LD
YAG40L-2NTC-LD-45
YAG40L-2NTC-LD-90
YAG44L-2TC38-LD
YAG44L-2TC38-LD-45
YAG44L-2TC38-LD-90
YAG44L-2TC12-LD
YAG44L-2TC12-LD-45
YAG44L-2TC12-LD-90
YAG44L-2TC12E3-LD
YAG44L-2TC12E3-LD-45
YAG44L-2TC12E3-LD-90
YAG44L-2NTC-LD
YAG44L-2NTC-LD-45
YAG44L-2NTC-LD-90
YAG44L-2TC58-LD
YAG44L-2TC58-LD-45
YAG44L-2TC58-LD-90

45

Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2 1-3/4 1.63

1/2 1-3/4 1.98

3/8

102

1

2.18

1/2 1-1/4 2.18

1/2 1-1/2 2.18

1/2 1-3/4 2.18

5/8 1-1/2 2.18

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

90

Fig. 1

Fig. 2

Fig. 3

Conductor
Fig
***
#
AWG
MM2
1
2
646 kcmil
3

1
1600/24
2
3
1
2
3
1
2
3 777.7 kcmil
1
2
1925/24 500
3
1 750 kcmil CLASS I
2
3
1
2
3

B
T

Figure
Dimensions
(B) (T)
(L)
5.43
1.42 .30 5.42
3.91
5.43
1.42 .30 5.42
3.91
4.80
1.65 .33 4.75
3.02
5.11
1.65 .33 5.07
3.33
5.36
1.65 .33 5.32
3.58
5.80
1.65 .33 5.75
4.02
5.61
1.65 .33 5.57
3.83

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

U39RT (2)

Black

24 1-5/16

U44XRT (2)

Yellow L115 1-5/8

Y644M (1)

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TWO HOLE HYLUG
FLEX CONDUCTOR
LONG BARREL
BELLED END

DIE AND COLOR


CODE INFORMATION

BELLED END
ASSISTS
FLEXIBLE WIRE
INSERTION

NO INSPECTION
WINDOW
CRIMPS

TYPES YA-2TC-FXB,
YAV-2TC-FXB

CABLE
ACCOMMODATION

ELECTRO-TIN
PLATED

COPPER COMPRESSION
TERMINAL

UL Listed 90 C,
600 Volts to 35 kV

90

T
45

Fig. 1

Fig. 2

Fig. 3

Conductor
Catalog Number
YA8C2TC14E2-FXB
YA8C2TC14-FXB
YA8C2TC38-FXB
YAV6C2TC14E2-FXB
YAV6C2TC14-FXB
YAV6C2TC38-FXB
YAV6C2N-FXB
YAV5C2TC14-FXB
YAV4C2TC14E2-FXB
YAV4C2TC14E1-FXB
YAV4C2TC14-FXB
YAV4C2TC516-FXB
YAV4C2TC38-FXB
YAV4C2N-FXB
YA3C2TC516-FXB
YA3C2TC38-FXB
YA3C2N-FXB
YAV2C2TC14-FXB
YAV2C2TC14E2-FXB
YAV2C2TC14E1-FXB
YAV2C2TC516-FXB
YAV2C2TC38-FXB
YAV2C2NT38-FXB
YAV2C2N-FXB
YAV1C2TC14-FXB
YAV1C2TC14E2-FXB
YAV1C2TC38-FXB
YAV1C2N-FXB
YAV252TC14-FXB
YAV252TC14E2-FXB
YAV252TC38-FXB

Fig
#
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

AWG
37/24
# 8 WELD
#8 AWG

***
MM2
**
10

61/24
#6 WELD
#6 AWG

**
16

#5 AWG

91/24 - 105/24
#4 WELD

#4 AWG
105/24 - 125/24
#3 WELD
#3 AWG

125/24 - 150/24
#2 WELD

35

#2 AWG
175/24 - 225/24
#1 WELD
#1 AWG

275/24
50
1/0 WELD

Stud
Hole
Size
1/4
1/4
3/8
1/4
1/4
3/8
1/2
1/4
1/4
1/4
1/4
5/16
3/8
1/2
5/16
3/8
1/2
1/4
1/4
1/4
5/16
3/8
3/8
1/2
1/4
1/4
3/8
1/2
1/4
1/4
3/8

Consult cable manufacturers for stress relief instructions.


For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.
** The MM2 conductor sizes referenced here are for both
Class 2 and Class 5 conductors.

Stud
Hole
Spacing
3/4
5/8
1
3/4
5/8
1
1-3/4
5/8
3/4
1
5/8
1
1
1-3/4
1
1
1-3/4
5/8
3/4
1
1
1
1
1-3/4
5/8
3/4
1
1-3/4
5/8
3/4
1

Figure
Tongue
Dimensions
Dieless
Width (B) (T)
(L)
(# of crimps)
.41 .90 .08 2.54 Y8MRB-1 (2)
.41 .90 .08 2.41 Y2MR + Y1MR (2)
.57 .90 .06 2.98 MY29-11 (2)
.48 1.22 08 2.88
Y1MR (2)
.48 1.22 .08 2.76
Y2MR (2)
.60 1.22 .06 3.32 MY29-11 (2)
.77 1.22 .04 4.51
Y644M (1)
.44 1.22 .07 2.76
Y644M (1)
.55 1.22 .09 2.93
.55 1.22 .09 3.18
Y2MR (4)
.55 1.22 .09 2.81 MY29-11 (2)
.55 1.22 .09 3.24
Y644M (1)
.63 1.22 .09 3.37
Y1MR (4)
.77 1.22 .09 4.56
.55 1.48 .09 3.51
.58 1.48 .09 3.64
.77 1.48 .09 4.83
.67 1.35 .10 3.00
.67 1.35 .10 3.13
.67 1.35 .10 3.38
.67 1.35 .10 3.44
.67 1.35 .10 3.57
MY29-11 (2)
.48 1.35 .10 3.57
Y644M (1)
.77 1.35 .09 4.76
.75 1.50 .12 3.17
.75 1.50 .12 3.30
.75 1.50 .12 3.74
.77 1.50 .12 4.92
.83 1.50 .12 3.21
.83 1.50 .12 3.34
.83 1.50 .12 3.78

Mechanical
MD6, OUR840,
MD7-34R
W8CRT (2)
W8CVT (2)
X8CRT (2)

Wire
Color Die Strip
Code Index Length
Red

49

1

W5CVT (2) W5CVT (2)


W5CRT (2) W5CRT (2)
X5CRT (2) X5CRT (2)

U5CRT (2)

Blue

1-5/16

W4CVT (2) W4CVT (2)


W4CRT (2) W4CRT (2)
X4CRT (2) X4CRT (2)

U4CRT (2)

Gray

1-5/16

W3CRT (2) W3CRT (2)

U3CRT (2)

White

1-9/16

W2CVT (2) W2CVT (2)


W2CRT (2) W2CRT (2)
X2CRT (2) X2CRT (2)

U2CRT (2)

Brown

10 1-7/16

U1CRT-1 (2)

Green

11 1-9/16

U25RT (2)

Pink

12 1-9/16

W1CVT (2) W1CVT (2)


W1CRT-1 (2) W1CRT-1 (2)
X1CRT-1 (2) X1CRT-1 (2)
W25RT (4) W25RT (4)
W25VT (4) W25VT (4)
X25RT (4) X25RT (4)

*** The MM2 conductor sizes listed are the recommendations


for Class 5 conductor.
P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for FX connectors.

For CUSTOMER SERVICE call 1-800-346-4175

Installation Tooling
Hydraulic
BCT500HS,
Y35,Y39,Y750,
Y500CTHS
Y46*, PAT750
W8CVT (2)
W8CRT (2)
U8CRT (2)
X8CRT (2)

Consult shielded cable manufactures for stress relief


instructions.

103

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
LONG BARREL
BELLED END
(Continued)

Catalog Number
YAV252N-FXB
YAV262TC14-FXB
YAV262TC14E2-FXB
YAV262TC38-FXB
YAV262NTC38-FXB
YAV262N-FXB
YAV272TC14E2-FXB
YAV272TC38-FXB
YAV272N-FXB
YAV282TC14E2-FXB
YAV282NT38-FXB
YAV282TC38-FXB
YAV282TC38-FXB-45
YAV282TC38-FXB-90
YAV282NTC38-FXB
YAV282N-FXB
YAV292TC14E2-FXB
YAV292NT38-FXB
YAV292TC38-FXB
YAV292TC38-FXB-45
YAV292TC38-FXB-90
YAV292NTC38-FXB
YAV292N-FXB
YA302TC38-FXB
YA302N-FXB
YA312TC38-FXB
YA312N-FXB
YA322TC38-FXB
YA322N-FXB
YA342TC14E2-FXB
YA342TC38-FXB
YA342N-FXB
YA342N-FXB-45
YA342N-FXB-90
YA382TC38-FXB
YA382TC38-FXB-45
YA382TC38-FXB-90
YA382N-FXB
YA382N-FXB-45
YA382N-FXB-90
YA382-FXBG2
YA382-FXBG3
YA402N-FXB
YA442TC38-FXB
YA442N-FXB
YA462N-FXB

Fig
#
1
1
1
1
1
1
1
1
1
1
1
1
2
3
1
1
1
1
1
2
3
1
1
1
1
1
1
1
1
1
1
1
2
3
1
2
3
1
2
3
1
1
1
1
1

AWG
1/0 AWG

***
MM2
50

325/24
2/0 WELD
2/0 AWG

70

450/24
3/0 WELD
3/0 AWG

95

550/24
4/0 WELD
4/0 AWG

** 3/8
120

Tongue
Width
.83
.93
.93
.93
.93
.93
1.02
1.02
1.02
1.14
.75

1

1.14

1

1.14

1-3/4
1-3/4
1
1-3/4
1
1-3/4
1
1-3/4
3/4
1

1.14
1.14
1.20
1.20
1.29
1.29
1.40
1.40
1.55
1.55

4/0 WELD
3/8
1/2
250 FLEX - CLASS G 259 STR 3/8
CLASS H 427 STR 1/2
250 FLEX
3/8
150
637/24 CLASS I, K, M
1/2
775/24
3/8
185
313.1 kcmil
1/2
1/4
925/24
3/8
373.7 kcmil 240
(350 kcmil nom.)
1/2

3/8

1-3/4 1.55

1

1.84

1325/24
300
535.3 kcmil (500kcmil nom.)
1/2 1-3/4 1.84

Figure
Dimensions
(B) (T)
(L)
1.50 .12 4.96
1.63 .13 3.40
1.63 .13 3.52
1.63` .13 3.96
1.63 .13 4.71
1.63 .13 5.15
1.64 .14 3.58
1.64 .14 4.01
1.64 .14 5.20
1.77 .14 3.76
1.77 .14 4.20
4.20
1.77 .14 3.92
2.39
1.77 .14 4.20
1.77 .14 5.39
2.00 .15 3.76
2.00 .15 4.20
4.20
2.00 .15 3.92
2.39
2.00 .15 4.20
2.00 .15 5.39
2.16 .16 4.61
2.12 .16 5.80
2.18 .18 4.66
2.18 .18 5.85
2.32 .19 4.85
2.32 .19 6.04
2.48 .23 4.66
2.48 .23 5.10
6.29
2.48 .23 5.93
3.73
6.01
3.08 .26 5.46
2.86
7.01
3.08 .26 6.46
3.84
3.08 .27 6.82
3.08 .27 6.26
3.24 .30 7.22
3.33 .33 6.44
3.33 .33 7.44

3/8
2
1.84
1/2 1-7/8 1.84
1600/24 646 kcmil 400 1/2 1-3/4 1.98
1925/24
3/8
1
2.19
500
777.7 kcmil (750kcmil nom.)
1/2 1-3/4 2.19
2750/24
1
1/2 1-3/4 2.69 3.58 .39 7.91
1111 kcmil (1000kcmil nom.)

Consult cable manufacturers for stress relief instructions.


For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.

104

Stud
Hole
Spacing
1-3/4
5/8
3/4
1
1-3/4
1-3/4
3/4
1
1-3/4
3/4
1

550/24
3/8

T
45

3/8 1-3/4 1.14


1/2 1-3/4 1.14
1/4 3/4 1.14
3/8
1
.75
-

90

T
L

Fig. 1

Fig. 2

Fig. 3

Conductor
Stud
Hole
Size
1/2
1/4
1/4
3/8
3/8
1/2
1/4
3/8
1/2
1/4
3/8

B
T

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W26VT (4) W26VT (4)


W26RT (4) W26RT (4)
X26RT (4) X26RT (4)

U26RT (2)

Black

13

1-13/16

W27RT (4) W27RT (4)


MY29-11 (2) W27VT (4) W27VT (4)
Y644M (1) X27RT (4) X27RT (4)

U27RT (2)

Orange

14

1-13/16

W28VT (4) W28VT (4)


W28RT (4) W28RT (4)
X28RT (6) X28RT (6)

U28RT (2)

Purple

15

1-7/8

W29VT (4)
W29RT (4)
X29RT (6)

U29RT (2)

Yellow

16

1-7/8

U30RT (4)

White

17

2-1/4

U31RT (4)

Red

18

2-1/4

W29VT (4)
X29RT (6)

W30VT (4)
W31VT (4)
Y644M (1)

W30RT (4)
W30VT (4)
W31RT (4)
W31VT (4)

W32VT (4)

W32VT (4)
W32RT (4)

U32RT (4)

Blue

19 2-9/16

U38XRT (4)

Pink

L99 3-3/16

U39RT (4)

Black

24 3-5/16

U44XRT (4)

Yellow L115 3-7/16

P45RT (4)

Yellow

** The MM2 conductor sizes referenced here are for both


Class 2 and Class 5 conductors.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.
P-RT die sets for use in Y46 HYPRESS only, PUADP-1
adapter not required.

29

3-11/16

See tooling section of this catalog for complete tool and


die listings. Use ONLY color-coded die recommendations
for -FX connectors.
Consult shielded cable manufactures for stress relief
instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TWO HOLE HYLUG
FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW

BEVELED
ENTRY

DIE AND COLOR


CODE INFORMATION

INSPECTION
WINDOW
CRIMPS

TYPE YAZ-FX
ELECTRO-TIN
PLATED

CABLE
ACCOMMODATION

UL Listed 90 C,
600 Volts to 35 kV

90

T
45
L

Fig. 1

Fig. 2

Fig. 3

Conductor
Catalog Number
YAZ8C2TC10FX
YAZ8C2TC10FX45
YAZ8C2TC10FX90
YAZ8C2TC10E2FX
YAZ8C2TC10E2FX45
YAZ8C2TC10E2FX90
YAZ8C2TC14E1FX
YAZ8C2TC14E1FX45
YAZ8C2TC14E1FX90
YAZ8C2TC14FX
YAZ8C2TC14FX45
YAZ8C2TC14FX90
YAZ8C2TC14E2FX
YAZ8C2TC14E2FX45
YAZ8C2TC14E2FX90
YAZ8C2TC38FX
YAZ8C2TC38FX45
YAZ8C2TC38FX90
YAZV6C2TC10E2FX
YAZV6C2TC10E2FX45
YAZV6C2TC10E2FX90
YAZV6C2TC14FX
YAZV6C2TC14FX45
YAZV6C2TC14FX90
YAZV6C2TC14E2FX
YAZV6C2TC14E2FX45
YAZV6C2TC14E2FX90
YAZV6C2TC14E1FX
YAZV6C2TC14E1FX45
YAZV6C2TC14E1FX90
YAZV6C2TC38FX
YAZV6C2TC38FX45
YAZV6C2TC38FX90

Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

AWG

***
MM2

37/24
#8 WELD

Stud Stud
Hole Hole Tongue
Size Spacing Width
# 10

5/8

.41

# 10

3/4

.41

1/4

1

.44

**
10

#3 AWG

1/4

5/8

.44

1/4

3/4

.44

3/8

1

.58

# 10

3/4

.48

1/4

5/8

.48

1/4

3/4

.48

1/4

1

.48

3/8

1

.58

61/24
#6 WELD

**
16

#6 AWG

* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.


** The MM2 conductor size referenced here is for both Class
2 and Class 5 conductor.
*** The MM2 conductor size listed are the recommendations
for Class 5 conductor.

Figure
Dimensions
(B) (T)
(L)
2.20
.75 .08 2.09
1.37
2.33
.75 .08 2.22
1.50
2.70
.75 .08 2.60
1.87
2.32
.75 .08 2.20
1.
2.45
.75: .08 2.33
1.62
2.89
.75 .06 2.72
2.05
2.64
.75 .08 2.48
1.51
2.65
.75 .08 2.45
1.51
2.78
.75 .08 2.58
1.63
3.03
.75 .08 2.83
1.88
3.22
.75 .06 2.97
2.06

Dieless
(# of crimps)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

Y8MRB-1 (1)
W8CVT (2) W8CVT (2)
Y2MR (2)
W8CRT (2)) W8CRT (2)
MY29-11 (2)
X8CRT (2) X8CRT (2)
Y1MR (2)

U8CRT (2)

Red

49

1

Y2MR (2)
W5CVT (2) W5CVT (2)
MY29-11 (2)
W5CRT (2) W5CRT (2)
Y644M (1)
X5CRT (2) X5CRT (2)
Y1MR (2)

U5CRT (2)

Blue

1-3/16

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connecotrs. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

105

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Catalog Number
YAZV6C2TC38E2FX
YAZV6C2TC38E2FX-45
YAZV6C2TC38E2FX-90
YAZV6C2TC38E6FX
YAZV6C2TC38E6FX-45
YAZV6C2TC38E6FX-90
YAZV4C2TC38E2-FX
YAZV4C2TC38E2-FX-45
YAZV4C2TC38E2-FX-90
YAZV4C2TC38FX
YAZV4C2TC38FX45
YAZV4C2TC38FX90
YAZV4C2TC14FX
YAZV4C2TC14FX45
YAZV4C2TC14FX90
YAZV4C2TC14E2FX
YAZV4C2TC14E2FX45
YAZV4C2TC14E2FX90
YAZV2C2TC14FX
YAZV2C2TC14FX45
YAZV2C2TC14FX90
YAZV2C2TC14E2FX
YAZV2C2TC14E2FX45
YAZV2C2TC14E2FX90
YAZV2C2TC38FX
YAZV2C2TC38FX45
YAZV2C2TC38FX90
YAZV2C2NTCFX
YAZV2C2NTCFX45
YAZV2C2NTCFX90
YAZV1C2TC14FX
YAZV1C2TC14FX45
YAZV1C2TC14FX90
YAZV1C2TC14E1FX
YAZV1C2TC14E1FX45
YAZV1C2TC14E1FX90
YAZV1C2TC14E2FX
YAZV1C2TC14E2FX45
YAZV1C2TC14E2FX90
YAZV1C2TC38FX
YAZV1C2TC38FX45
YAZV1C2TC38FX90
YAZV1C2TC516E6FX
YAZV1C2TC516E6FX-45
YAZV1C2TC516E6FX-90
YAZV1C2TC516FX
YAZV1C2TC516FX45
YAZV1C2TC516FX90

106

3/4

.58

3/8

7/8

.58

3/8

3/4

.58

3/8

1

.58

1/4

5/8

.55

1/4

3/4

.55

1/4

5/8

.68

1/4

3/4

.68

3/8

1

.68

1/2

1-3/4

.83

1/4

5/8

.75

1/4

1

.75

1/4

3/4

.75

3/8

1

.75

5/16

7/8

.75

5/16

1

.75

* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.


** The MM2 conductor size referenced here is for both Class
2 and Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

T
45

Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8

90

T
L

Fig. 1

Fig. 2

Conductor
Fig
***
#
AWG
MM2
1
2
61/24
3
**
#6 WELD
1
16
#6 AWG
2
3
1
2
3
1
91/24-105/24
2
3
#4 WELD
1
2
#4 AWG
3
1
2
3
1
2
3
1
125/24-150/24
2
3
#2 WELD 35
1
2
#2 AWG
3
1
2
3
1
2
3
1
2
3
1
175/24-225/24
2
3
#1 WELD
1
2
#1 AWG
3
1
2
3
1
2
3

Figure
Dimensions
(B) (T)
(L)
2.97
.75 .06 2.72
1.81
3.09
.75 .06 2.85
1.94
3.14
1.25 08 2.88
1.86
3.39
1.25 .08 3.13
2.11
2.83
1.25 .09 2.59
1.55
2.95
1.25 .09 2.72
1.68
3.01
1.38 .10 2.75
1.60
3.13
1.38 .10 2.87
1.73
3.57
1.38 .10 3.31
2.16
4.76
1.38 .10 4.50
3.35
3.04
1.38 .12 2.81
1.64
3.41
1.38 .12 3.18
2.01
3.16
1.38 .12 2.93
1.76
3.60
1.38 .12 3.37
2.20
3.35
1.38 .12 3.12
1.95
3.47
1.38 .12 3.24
2.08

Dieless
(# of crimps)

Y1MR (2)
Y2MR (2)
MY29-11 (2)
Y644M (1)

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W5CVT (2)
W5CRT (2)
X5CRT (2)

W5CVT (2)
W5CRT (2)
X5CRT (2)

U5CRT (2)

Blue

1-3/16

W4CVT (2)
W4CRT (2)
X4CRT (2)

W4CVT (2)
W4CRT (2)
X4CRT (2)

U4CRT (2)

Gray

1-5/16

W2CVT (2)
W2CRT (2)
X2CRT (2)

W2CVT (2)
W2CRT (2)
X2CRT (2)

U2CRT (2)

Brown

10

1-7/16

W1CVT (2) W1CVT (2)


W1CRT-1 (2) W1CRT-1 (2)
X1CRT-1 (2) X1CRT-1 (2)

U1CRT-1 (2)

Green

11

1-7/16

Y1MR (4)
Y2MR (4)
MY29-11 (2)
Y644M (1)

MY29-11 (2)
Y644M (1)

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connecotrs. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)

Catalog Number
YAZV252TC14FX
YAZV252TC14FX45
YAZV252TC14FX90
YAZV252TC14E2FX
YAZV252TC14E2FX45
YAZV252TC14E2FX90
YAZV252TC38FX
YAZV252TC38FX45
YAZV252TC38FX90
YAZV252NTCFX
YAZV252NTCFX45
YAZV252NTCFX90
YAZV262TC14FX
YAZV262TC14FX45
YAZV262TC14FX90
YAZV262TC14E2FX
YAZV262TC14E2FX45
YAZV262TC14E2FX90
YAZV262TC38FX
YAZV262TC38FX45
YAZV262TC38FX90
YAZV262NTCFX
YAZV262NTCFX45
YAZV262NTCFX90
YAZV272TC14E2FX
YAZV272TC14E2FX-45
YAZV272TC14E2FX-90
YAZV272TC38FX
YAZV272TC38FX45
YAZV272TC38FX90
YAZV282TC14E2FX
YAZV282TC14E2FX45
YAZV282TC14E2FX90
YAZV282NT38FX
YAZV282NT38FX-45
YAZV282NT38FX-90
YAZV282TC38FX
YAZV282TC38FX45
YAZV282TC38FX90
YAZV282NTCFX
YAZV282NTCFX45
YAZV282NTCFX90
YAZV292NT516FX
YAZV292NT516FX-45
YAZV292NT516FX-90

AWG

***
MM2

275/24
1/0 WELD

325/24
2/0 WELD

5/8

.83

1/4

3/4

.83

1

.83

1/2 1-3/4

.83

1/4

5/8

.93

1/4

3/4

.93

3/8

1

.93

1/2 1-3/4

.93

1/4

1.03

3/4

95

550/24
4/0 WELD

1/4

70

2/0 AWG

450/24
3/0 WELD
3/0 AWG

Stud Stud
Hole Hole Tongue
Size Spacing Width

3/8

**
120

4/0 AWG

3/8

1

1.03

1/4

3/4

1.14

3/8

1

.94

3/8

1

1.14

1/2 1-3/4 1.14


550/24
4/0 WELD

5/16 1-3/4 1.20

* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.


** The MM2 conductor size referenced here is for both Class
2 and Class 5 conductor.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

T
45

50

1/0 AWG

90

Fig. 1

Fig. 2

Conductor
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

Figure
Dimensions
(B) (T)
(L)
3.20
1.50 .12 2.92
1.66
3.32
1.50 .12 3.04
1.79
3.76
1.50 .12 3.48
2.23
4.95
1.50 .12 4.67
3.41
3.20
1.50 .13 2.92
1.66
3.32
1.50 .13 3.05
1.79
3.76
1.50 .13 3.48
2.23
4.95
1.50 .13 4.67
3.41
3.36
1.50 .14 3.08
1.82
3.80
1.50 .14 3.52
2.25
3.52
1.62 .15 3.23
1.86
3.96
1.62 .15 3.67
2.30
3.96
1.62 .15 3.67
2.30
4.93
1.62 .15 4.64
3.27
4.62
2.00 .16 4.35
2.96

Dieless
(# of crimps)

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750

Wire
Color Die Strip
Code Index Length

W25VT (4) W25VT (4)


W25RT (4) W25RT (4)
X25RT (4) X25RT (4)

U25RT (2)

Pink

12 1-9/16

W26VT (4) W26VT (4)


W26RT (4) W26RT (4)
X26RT (4) X26RT (4)

U26RT (2)

Black

13 1-9/16

W27VT (4) W27VT (4)


W27RT (4) W27RT (4)
X27RT (4) X27RT (4)

U27RT (2)

Orange 14 1-9/16

W28VT (4) W28VT (4)


W28RT (4) W28RT (4)
X28RT (6) X28RT (6)

U28RT (2)

Purple 15 1-11/16

W29RT (4)
W29VT (4)
X29RT (8)

U29RT (2)

Yellow

MY29-11 (2)
Y644M (1)

Y644M (1)

W29VT (4)
X29RT (8)

16 1-11/16

See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connectors. For nest/indentor system contact factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

107

BURNDY
Telecommunications Products

TWO HOLE HYLUG


FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)

Catalog Number
YAZ302TC38FX
YAZ302TC38FX-45
YAZ302TC38FX-90
YAZ312TC38FX
YAZ312TC38FX45
YAZ312TC38FX90
YAZ312TC14E2FX
YAZ312TC14E2FX-45
YAZ312TC14E2FX-90
YAZ322TC38FX
YAZ322TC38FX45
YAZ322TC38FX90
YAZ342TC14E2FX
YAZ342TC14E2FX-45
YAZ342TC14E2FX-90
YAZ342NT38FX
YAZ342NT38FX-45
YAZ342NT38FX-90
YAZ342TC38FX
YAZ342TC38FX45
YAZ342TC38FX90
YAZ342NTCFX
YAZ342NTCFX45
YAZ342NTCFX90
YAZ362TC38FX
YAZ362TC38FX45
YAZ362TC38FX90
YAZ382NT38FX
YAZ382NT38FX-45
YAZ382NT38FX-90
YAZ382TC38FX
YAZ382TC38FX45
YAZ382TC38FX90
YAZ382NNTFX
YAZ382NNTFX-45
YAZ382NNTFX-90
YAZ382NTCFX
YAZ382NTCFX45
YAZ382NTCFX90

***
MM2

AWG
250 FLEX
CLASS G 259 STR.
CLASS H 427 STR.

250 FLEX
637/24 150
CLASS I, K, M

775/24
185
313.1 kcmil

373.3 kcmil
925/24

Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8

1

1.20

3/8

1

1.28

1/4

3/4

1.29

3/8

1

1.55

1/4

3/4

1.55

3/8

1

.96

3/8

1.55

535.3 kcmil
1325/24
(500 MCM NOM)

3/8

1

1.72

3/8

1

1.63

3/8

1

1.81

300
1/2 1-3/4 1.63

1/2 1-3/4 1.81

* Use PUADP-1 adaptor with "U" -dies in Y46 HYPRESS.


*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.
See tooling section of this catalog for complete tool and die
listings. Use ONLY color-coded die recommendations for
-FX connecotrs. For nest/indentor system contact factory.

108

1

1/2 1-3/4 1.55


1100/24
444.4 kcmil

T
45

240

(350 MCM NOM)

90

Figure
Dimensions
(B) (T)
(L)
4.42
2.00 .16 4.05
2.37
4.45
2.00 .18 4.10
2.41
4.02
2.00 .18 3.66
1.97
4.62
2.12 .19 4.25
2.46
4.42
2.25 .23 4.06
2.10
4.85
2.25 .23 4.50
2.54
4.85
2.25 .23 4.50
2.54
6.04
2.25 .23 5.69
3.73
5.55
2.69 .27 5.14
2.81
5.72
2.81 .27 5.26
2.84
5.72
2.81 .27 5.26
2.84
6.72
2.81 .27 6.26
3.84
6.72
2.81 .27 6.26
3.84

Fig. 1

Fig. 2

Conductor
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

Dieless
(# of crimps)

Fig. 3

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
W29RT (4)
W29VT (4) W29VT (4)
U29RT (2)
X29RT (8) X29RT (8)

Wire
Color Die Strip
Code Index Length
Yellow

16 2-1/16

W30VT (4)

W30VT (4)
W30RT (4)

U30RT (4)

White

17 2-1/16

W31VT (4)

W31VT (4)
W31RT (4)

U31RT (4)

Red

18 2-3/16

W32VT (4)

W32VT (4)
W32RT (4)

U32RT (4)

Blue

19 2-5/16

U34RT (4)

Brown

20

U38XRT (4)

Pink

L99 2-7/8

Y644M (1)

2-3/4

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YA-L-TCG1
SPLIT BARREL HYLUG
COPPER COMPRESSION
TERMINAL
UL Listed 90 C,
600 Volts to 35 kV

B
BURNDY
.12
YA25L 4TCG1
.75

1.38

1 0 AWG

DIE 12
.31
.62

Catalog
Number
YA25L-4TCG1
YA26L-4TCG1
YA27L-4TCG1
YA28L-4TCG1
YA29L-4TCG1
YA31L-4TCG1

Conductor
AWG
MM2
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 Kcmil
350 Kcmil

Metric
Bolt Bolt
Size Size

70mm2

1/4

2
120mm
180mm2

M6

B
0.88
0.94
1.00
1.00
1.06
1.06

For CUSTOMER SERVICE call 1-800-346-4175

Dimensions
Dieless (#
L Thickness of crimps)
3.05
3.15
3.25
3.29
3.39
3.46

0.11
0.21
0.21
0.21
0.21
0.21

Y644M (1)

Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS, Y35, Y39, Y750,
MD7-34R
Y500CTHS Y46*, PAT750
W25VT (1) or W25RT (1)
W26VT (1) or W26RT (1)
W27VT (1) or W27RT (1)
W28VT (1) or W28RT (1)
W29VT (1) or W29RT (1)
W31VT (1) or W31RT (1)

U25RT (1)
U26RT (1)
U27RT (1)
U28RT (1)
U29RT (1)
U31RT (1)

Wire
Color Die Strip
Code Index Length
Pink
Black
Orange
Purple
Yellow
Red

12
13
14
15
16
18

15/16
1
1-1/16
1-1/8
1-1/8
1-1/8

109

BURNDY
Telecommunications Products
TYPE YAS-L-2TC-FX,60
TWO HOLE HYLUG
DOUBLE BARREL
COPPER COMPRESSION
TERMINAL
UL Listed 90 C,
600 Volts to 35 kV

Fig. 1
CONDUCTOR

CATALOG NUMBER
YASG8CL-2TC14E2-FX
YASG8CL-2TC14E2-FX-60
YASG6CL-2TC14E2-FX
YASG6CL-2TC14E2-FX-60
YASV6CL-2TC14E2-FX**
YASV6CL-2TC14E2-FX-60**

FLEX AWG
#8
WELD
37/24
#6
WELD
61/24
#6
WELD
61/24

DIMENSIONS

*** BOLT FIG.


MM2 SIZE NO.

1
#8
AWG

10

1/4

.44
(11)

.44
(11)

.75
(19)

.50
(13)

.48
(12)

.75
(19)

.50
(13)

.48
(12)

.75
(19)

2
1
#6
AWG
#6
AWG

16

1/4
2
1

16

1/4
2

2.7
(70)

.66
(17)

.68
(17)

.68
(17)

2.6
(67)
3.0
(78)
2.9
(75)
3.0
(78)
2.9
(75)

Fig. 2
INSTALLATION TOOLING
MECHANICAL
HYDRAULIC
MD7-34 Y1MRTC
WIRE
T
Y
DIE COLOR MD6
Y2MR
Y750,Y35, STRIP
REF. MIN. INDEX CODE OUR840 Y8MRB-1 Y39,Y46* LENGTH
.08
(2)

1.14
(29)

49

RED

W8CVT
W8CRT
(1)

.08
(2)

1.14
(29)

7 or
374

BLUE

W5CVT
W5CRT
(1)

.08
(2)

1.14
(29)

7 or
374

BLUE

W5CVT
W5CRT
(1)

Y8MRB-1
Y2MR
(1)
Y1MRTC
(1)
Y2MR
(1)
Y1MRTC
(1)
Y2MR
(1)
Y1MRTC
(1)

U8CRT
(1)

1/2

U5CRT
(1)

9/16

U5CRT
(1)

9/16

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.
** Type YASV series have inspection hole.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 and Class 5 conductor.

110

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE CUSA
HYSTACK
TERMINAL STACKING
ADAPTOR
This HYSTACK adaptor is specially
designed to get terminals to the back end of a
bus bar or other areas that require terminals
to be elevated off the mounting surface. This
HYSTACK is made from high conductivity
copper and tin-plated to provide optimum corrosion resistance. It will accommodate #10
AWG through 750 kcmil HYLUGS.

Catalog
Number
CUSA442TC38
CUSA442NTC

Stud Hole
Size
3/8"
1/2"

Stud Hole
Spacing
1"
1 - 3/4"

Length
1.75"
2.50"

Width
1.12"
1.12"

Height
1.50"
1.50"

Reference: Catalog number TMH332.


This TMH332 Kit has just the right hardware
when using the CUSA442TC38 HYSTACK
on a 1/4" bus bar with a 4/0 through 750 kcmil
HYLUG.

For CUSTOMER SERVICE call 1-800-346-4175

111

BURNDY
Telecommunications Products
TYPE YS-L
HYLINK SPLICE
STANDARD BARREL
COPPER COMPRESSION
UL Listed 90 C,
600 Volts to 35 kV

Features and Benefits


Standard barrel length.
Ideal for limited space applications while
providing ample barrel length for proper
crimp.
Four (4) center conductor stops.
Provides a center wire stop for proper
conductor insertion.
CONDUCTOR

INSTALLATION TOOLING

DIMENSION

MD7-34R

MD6
OUR840

DIE NUMBER
(# CRIMPS)

COLOR
CODE

DIE INDEX
& EMBOSSMENT

WIRE
STRIP
LENGTH

W8CVT (1)

X8CRT (1)

U8CRT (1)

Red

49

1/2"

W5CVT (1)

X5CRT (1)

UCRT (1)

Blue

7 or 374

7/8"

W4CVT (1)

X4CRT (1)

U4CRT (1)

Gray

8 or 346

7/8"

U3CRT (1)

White

15/16"

W2CVT (1)

X2CRT (1)

U2CRT (1)

Brown

10

15/16"

W1CVT (1)
W25VT (2)
W26VT (2)
W27VT (2)
W28VT (2)
W29VT (2)
W30VT (2)
W31VT (2)
W32VT (2)
W34VT (2)

X1CRT (1)
X25RT (2)
X26RT (2)
X27RT (2)
X28RT (2)

U1CRT-1 (1)
U25RT (1)
U26RT (1)
U27RT (1)
U28RT (1)
U29RT (1)
U30RT (2)
U31RT (2)
U32RT (2)
U34RT (2)
U36RT (2)
U38RT (2)
U39RT (2)
P44RT** (2)

Green
Pink
Black
Orange
Purple
Yellow
White
Red
Blue
Brown
Green
Pink
Black
White

11 or 375
12 or 348
13
14
15
16
17 or 298
18 or 324
19 or 470
20 or 299
22 or 472
400
24
27

15/16"
15/16"
1"
1-1/16"
1-1/16"
1-1/8"
1-1/8"
1-3/16"
1-1/4"
1-7/16"
1-7/16"
1-7/16"
1-11/16"
1-15/16"

MECHANICAL
CATALOG
NUMBER

AWG

***
MM2

YS8C-L-BOX

8 str.

10

1.24

.44

YS6C-L BOX
YS5C-L BOX

6 str.
5 str.

16

1.75
1.90

.81
.81

YS4C-L BOX

4 str.

1.93

.81

YS3C-L

3 str.

25

2.05

.88

YS2C-L BOX

2 str.

2.07

.88

YS1C-L BOX
YS25-L BOX
YS26-L BOX
YS27-L BOX
YS28-L BOX
YS29-L BOX
YS30-L
YS31-L
YS32-L
YS34-L
YS36-L
YS38-L
YS39-L
YS44-L

1 str.
1/0 str.
2/0 str.
3/0 str.
4/0 str.
250 kcmil
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
700 kcmil
750 kcmil
1000 kcmil

50

70
95

120
150
185

240
300

500

2.06
2.08
2.17
2.30
2.32
2.46
2.47
2.60
2.74
3.15
3.22
3.22
3.72
4.28

.88
.88
.94
1.00
1.00
1.06
1.06
1.12
1.19
1.38
1.38
1.38
1.62
1.88

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.
** P44RT for use with Y46 HYPRESS only. PUADP-1
adaptor not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

112

Y1MRTC
Y2MR
Y2MR (1)
Y1MRTC (1)
Y2MR (1)
Y1MRTC (1)
Y2MR (2)
Y1MRTC (2)
Y1MRTC (2)
Y2MR (2)
Y1MRTC (2)
Y1MRTC (2)

Y35 , Y39, Y750, Y46*

The maximum size for the Y35 is 400 kcmil insulated code
cable.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instuctions.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YSCM

SEAMLESS
TUBING

ELECTRO-TIN
PLATED

HYLINK
COLOR-CODED UNINSULATED
PARALLEL SPLICE
Type YSCM HYLINK seamless parallel
splice connectors permit stranded wires to be
laid parallel inside the connector and spliced
together with BURNDY compression tools.
Each YSCM connector accommodates a
wide range of conductors and is color-coded
to ensure proper tool and die match. YSCM
connectors are UL 486A Listed for applications up to 600V and CSA Listed.

CATALOG
NUMBER

CONDUCTOR RANGE
CABLE
CIRCULAR MILS
MIN.
MAX.

YSCM17

13,060

16,910

YSCM27

16,910

26,890

YSCM42

29.970

41,520

YSCM66

42,750

66,040

YSCM80

67,980

80,020

YSCM104

82,870

103,630

YSCM133

104,960

133,220

YSCM167

134,340

166,560

YSCM212

167,380

211,820

YSCM231

230,800

DIMENSIONS
INCH [mm]
L
O.D.
.03
.01
.50
[13]
.50
[13]
.50
[13]
.62
[16]
.62
[16]
.69
[18]
.81
[21]
.81
[21]
.88
[22]
1.05
[27]

.27
[7]
.31
[8]
.38
[10]
.47
[12]
.52
[13]
.57
[14]
.64
[16]
.70
[18]
.78
[20]
.81
[21]

CIRCULAR MIL TABLE PER ASTM B8


SIZE
ASTM STRANDINGS
STRANDED
CIRCULAR
MILS
AWG
CLASS
1,022
20
B
1,624
18
B

RECOMMENDED INSTALLATION TOOLING


OUR840, Y500CTHS,
Y35, Y750,
BCT500HS SERIES
PAT750 SERIES

DIE
INDEX

Red

49

X8CRT, W8CRT

U8CRT

11/16

Blue

X5CRT, W5CRT

U5CRT

11/16

Gray

X4CRT, W4CRT

U4CRT

11/16

Brown

10

X2CRT, W2CRT

U2CRT

3/4

Green

11

X1CRT, W1CRT

U1CRT-1

3/4

Pink

12

X25RT, W25RT

U25RT

15/16

Black

13

X26RT, W26RT

U26RT

1-1/16

Orange

14

X27RT, W27RT

U27RT

1-1/16

Purple

15

X28RT, W28RT

U28RT

1-1/16

Yellow

16

X29RT, W29RT

U29RT

1-1/16

CABLE
DIAMETER
INCHES
0.036
0.045

16
14
12
10
9
8

B
B
B
B
B
B

0.057
0.072
0.091
0.116
0.130
0.146

20,820
26,250
33,100
41,740
41,740
52,630

7
6
5
4
4
3

B
B
B
AA
B&A
AA

0.164
0.184
0.206
0.254
0.232
0.285

CIRCULAR MIL TABLE PER ASTM B8


SIZE
ASTM STRANDINGS
STRANDED
CIRCULAR
MILS
AWG
CLASS
52,630
3
B&A
66,370
2
AA
66,370
2
B&A
83,690
1
AA
83,690
1
A
83,690
1
B

CABLE
DIAMETER
INCHES
0.260
0.320
0.292
0.360
0.328
0.332

105,500
105,500
105,500
133,100
133,100
133,100

1/0
1/0
1/0
2/0
2/0
2/0

A&A

B
A&A

0.368
0.390
0.373
0.414
0.438
0.419

167,800
167,800
167,800
211,600
211,600
211,600

3/0
3/0
3/0
4/0
4/0
4/0

A&A

B
A&A

0.464
0.492
0.470
0.522
0.522
0.528

Recommended strip length. Strip length dependant on

For CUSTOMER SERVICE call 1-800-346-4175

WIRE
STRIP
LENGTH

COLOR
CODE

2,583
4,107
6,530
10,380
13,090
16,510

1. Material: Copper per ASTM B75.


2. Finish: Tin plated. For nickel plating, add suffix NK to the
Catalog Number.
3. Dimensions in brackets [ ] are in millimeters rounded off to
the nearest millimeter, unless otherwise noted, and are for
reference only.

BEVELED
ENTRY

COLOR-CODE
AND DIE INDEX

size, no. of wires and insulation thickness.

Refer to Circular Mil Table per ASTM B8 for total Class B


Circular Mil calculations.

113

BURNDY
Telecommunications Products
TYPE YS

BEVELED
ENTRY

DIE AND COLOR


CODE INFORMATION

HYLINK SPLICE
LONG BARREL

ELECTRO-TIN
PLATED

COPPER COMPRESSION
SPLICE

CRIMP
CRIMP

UL Listed 90 C,
600 Volts to 35 kV

CRIMP
CRIMP

(4) CENTER
WIRE STOPS

Features and Benefits


Long barrel length.
Ideal for 600 volt heavy duty applications.
Also may be used at higher voltages up to
35KV.
Four (4) center conductor stops.
Provides a center wire stop for proper
conductor insertion.
High pull out force.
Provides added security for much greater
mechanical and electrical properties.
CONDUCTOR

INSTALLATION TOOLING

DIMENSION

MD7-34R
W8CVT (2)

MD6
OUR840
X8CRT (2)

DIE NUMBER
(# CRIMPS)
U8CRT (2)

COLOR
CODE
Red

DIE INDEX
& EMBOSSMENT
49

WIRE
STRIP
LENGTH
7/8"

W5CVT (2)

X5CRT (2)

U5CRT (2)

Blue

7 or 374

1-3/16"

W4CVT (2)

X4CRT (2)

U4CRT (2)

Gray

8 or 346

1-3/16"

MECHANICAL
CATALOG
NUMBER
YS8C
YS6C
YS5C
YS4C
YS3C
YR2C2WT
YS2C
YS1C
YS25
YS26
YS27
YS28
YS29
YS30
YS31
YS32
YS34
YS36
YS39
YS44
YS46
YS48

AWG
8 str.
6 str.
5 str.

***
MM2
10

16

L
1.75
2.38
2.55

B
.78
1.09
1.09

4 str.

2.55

1.09

3 str./2 sol.
2 str. - 2 sol.
2 str.
1 str.
1/0 str.
2/0 str.
3/0 str.
4/0 str.
250 kcmil
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
1500 kcmil
2000 kcmil

25
25
35
50

70

120
150
185

240
300

500

2.80
2.90
2.82
3.07
3.06
3.30
3.30
3.57
3.58
4.34
4.35
4.62
4.91
5.85
6.38
6.95
7.01
7.57

1.22
1.44
1.22
1.34
1.34
1.45
1.45
1.58
1.58
1.95
1.95
2.08
2.20
2.63
2.81
2.94
3.13
3.27

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P44RT for use with Y46 HYPRESS only. PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.

114

Y1MRTC
Y2MR
Y2MR (2)
Y1MRTC (2)
Y2MR (4)
Y1MRTC (4)
Y1MRTC (4)
Y2MR (4)
Y1MRTC (4)
Y1MRTC (4)

Y35 , Y39, Y750, Y46*

White

1-5/16"

W2CVT/W2CRT

W2CVT/W2CRT

W2CVT (2)
W1CVT (2)
W25VT (4)
W26VT (4)
W27VT (4)
W28VT (4)
W29VT (4)
W30VT (4)
W31VT (4)
W32VT (4)
W34VT (4)

X2CRT (2)
X1CRT (2)
X25RT (4)
X26RT (4)
X27RT (4)
X28RT (4)

U2CRT (2)
U2CRT (2)
U1CRT-1 (2)
U25RT (2)
U26RT (2)
U27RT (2)
U28RT (2)
U29RT (2)
U30RT (4)
U31RT (4)
U32RT (4)
U34RT (4)
U36RT (4)
U39RT (4)
P44RT** (4)
P46RT** (6)
L48RT (4)

Brown
Brown
Green
Pink
Black
Orange
Purple
Yellow
White
Red
Blue
Brown
Green
Black
White
Green
Brown

10
10
11 or 375
12 or 348
13
14
15
16
17 or 298
18 or 324
19 or 470
20 or 299
22 or 472
24
27
31
34

1-5/8"
1-5/16"
1-7/16"
1-7/16"
1-9/16"
1-9/16"
1-11/16"
1-11/16"
2-1/16"
2-1/16"
2-3/16"
2-5/16"
2-3/4"
2-15/16"
3-1/16"
3-1/4"
3-3/8"

The maximum size for the Y35 is 400 kcmil.


See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instuctions.
Requires Y60BHU HYPRESS with L48RT die set.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YS-FXB

Features and Benefits


Long barrel length.
High voltage terminations.
Four (4) center conductor stops.
Provides a center wire stop for proper
conductor insertion.
High pull out force.
Provides added security for greater
mechanical and electrical properties.
Belled cable entry.
A funnel type entry provide easy insertion of extra flexible cables plus offers
mechanical strain relief for individual
strands.

HYLINK SPLICE
BELLED LONG BARREL
UL Listed 90 C,
600 Volts to 35 kV

CONDUCTOR
CATALOG
NUMBER
YS8C-FXB
YSV6C-FXB
YS5C-FXB
YSV4C-FXB
YS3C-FXB
YSV2C-FXB
YSV1C-FXB
YSV25-FXB
YSV26-FXB
YSV27-FXB
YSV28-FXB
YS30-FXB
YS31-FXB
YS32-FXB
YS34-FXB
YS36-FXB
YS38-FXB
YS40-FXB
YS44-FXB

FLEXIBLE CABLE
CODE AWG
#8 STR. (37/24)
#8 AWG
#6 STR. (61/24)
#6 AWG
#5 STR. (91/24)
#5 AWG
#4 STR. (91/24-105/24)
#4 AWG
#3 STR. (105/24-125/24)
#3 AWG
#2 STR. (125/24-150/24)
#2 AWG
#1 STR. (175/24-225/24)
#1 AWG
1/0 STR. (275/24)
1/0 AWG
2/0 STR. (325/24)
2/0 AWG
3/0 STR. (450/24)
3/0 AWG
4/0 STR. (550/24)
4/0 AWG
250 kcmil Flex
Class G 259 STR.
Class H 427 STR.
263 kcmil (650/24)
250 FLEX CLASS I, K, M
313.1 kcmil (775/24)
300 kcmil NOM.
373 kcmil (925/24)
350 kcmil NOM.
444.4 kcmil (1100/24)
450 kcmil NOM.
535.3 kcmil (1325/24)
500 kcmil NOM.
646 kcmil (1600/24)
600 kcmil NOM.
777.7 kcmil (1925/24)
750 kcmil NOM.

DIMENSIONS
***
MM2
10

16

25
35

50
70
95

120

150
185
240
300

400
500

* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS.


** P44RT and P46RT dies sets are for use with Y46
HYPRESS only. PUADP-1 adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 5 conductor.

L
(mm)
1.99
(51)
2.62
(67)
2.62
(67)
2.62
(67)
2.87
(73)
2.89
(73)
3.18
(81)
3.18
(81)
3.44
(87)
3.46
(88)
3.72
(94)

B
(mm)
.90
(23)
1.22
(31)
1.22
(31)
1.22
(31)
1.47
(37)
1.35
(34)
1.50
(38)
1.50
(38)
1.63
(41)
1.64
(42)
1.77
(45)

4.51
(115)

2.16
(55)

4.54
(115)
4.82
(122)
5.14
(131)
6.09
(155)
6.34
(161)
6.66
(1.69)
6.84
(174)

2.18
(55)
2.32
(59)
2.48
(63)
2.95
(75)
3.08
(78)
3.24
(82)
3.33
(85)

INSTALLATION TOOLING
MECHANICAL
Y1MRTC
Y2MR
Y2MR (2)
Y1MR (2)
Y2MR (2)
Y1MR (2)
Y2MR (2)
Y1MR (2)
Y2MR (4)
Y1MR (4)

Y35 , Y39, Y750, Y46*

EMBOSSED
DIE INDEX

COLOR
CODE

49

Red

Blue

Blue

Gray

Y1MR (4)

White

Y2MR (4)
Y1MR (4)

10

Brown

11

Green

12

Pink

13

Black

14

Orange

15

Purple

16

Yellow

17

White

18

Red

19

Blue

20

Brown

L99

Pink

24

Black

L115

Yellow

16mm2 and 120mm2 referenced are for both Class 2 and


Class 5
The maximum size for the Y35 is 373.7 kcmil.
See tooling section of this catalog for complete tool and die
listings.

For CUSTOMER SERVICE call 1-800-346-4175

DIE NUMBER (# of
Crimps)
U8CRT
(2 Crimps/End)
U5CRT
(2 Crimps/End)
U5CRT
(2 Crimps/End)
U4CRT
(2 Crimps/End)
U3CRT
(2 Crimps/End)
U2CRT
(2 Crimps/End)
U1CRT-1
(4 Crimps/End)
U25RT
(4 Crimps/End)
U26RT
(4 Crimps/End)
U27RT
(4 Crimps/End)
U28RT
(4 Crimps/End)

CABLE
STRIP
LENGTH
1"
(25)
1-5/16"
(33)
1-5/16"
(33)
1-5/16"
(33)
1-9/16"
(40)
1-7/16"
(37)
1-9/16"
(40)
1-9/16"
(40)
1-11/16"
(43)
1-11/16"
(43)
1-7/8"
(48)

U29RT
(4 Crimps/End)

2-1/4"
(57)

U30RT
(4 Crimps/End)
U31RT
(4 Crimps/End)
U32RT
(4 Crimps/End)
U34RT
(4 Crimps/End)
U38XRT
(4 Crimps/End)
U39RT
(4 Crimps/End)
U44XRT
(4 Crimps/End)

2-1/4"
(57)
2-7/16"
(62)
2-9/16"
(65)
3-1/16"
(79)
3-3/16"
(81)
3-5/16"
(84)
3-7/16"
(87)

For applications greater than 2000 Volts consult cable


manufacturer for voltage stress relief instructions.

115

BURNDY
Telecommunications Products
TYPE YS-TC
HYSPLICE
In-line Splice Kits for
Telecommunications
Applications
YS-TC kits are for splicing cables and covering the connection with clear heat shrink.
Splices are constructed from seamless, high
conductivity electrolytic copper tubing for
maximum conductivity and tin-plated to resist
corrosion. Each YS-TC splice is provided with
inspection holes and cable stops. The YS-TC
family also features the BURNDY color code
system. Clear heat shrink kits.

Plastic
Bag/Kit

* Clear

Wire Size
AWG
750 kcmil
FLEX
750 kcmil
CODE
500 kcmil
FLEX
500 kcmil
CODE
350 kcmil
FLEX
350 kcmil
CODE
4/0 AWG
FLEX
4/0 AWG
CODE
2/0 AWG
FLEX or CODE
1/0 AWG
FLEX or CODE
#2 AWG
FLEX or CODE

mm2
500 mm2
Class 5

mm2

300
Class 5
240 mm2
Class 2
240 mm2
Class 5
185 mm2
Class 2

mm2

70
Class 5
50 mm2
Class 5
35 mm2
Class 5

Heat Shrink Kit


Catalog Number

Barrel
Type

YS44FXLTCKITC
YS44FXTCKITC
YS39LTCKITC
YS39TCKITC
YS38FXLTCKITC
YS38FXTCKITC
YS34LTCKITC
YS34TCKITC
YS34FXLTCKITC
YS34FXTCKITC
YS31LTCKITC
YS31TCKITC
YS29FXLTCKITC
YS29FXTCKITC
YS28LTCKITC
YS28TCKITC
YS26FXLTCKITC
YS26FXTCKITC
YS25FXLTCKITC
YS25FXTCKITC
YS2CFXLTCKITC
YS2CFXTCKITC

Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long

Connector
Dimensions
Barrel Length
Color Code
B
L
1.90
3.02
1.62
2.66
1.71
2.62
1.56
2.43
1.56
2.43
1.39
2.32
1.36
2.27
1.23
2.04
1.09
1.79
0.98
1.59
0.77
1.25

4.30
6.55
3.68
5.77
3.87
5.69
3.51
5.24
3.51
5.24
3.10
4.96
2.98
4.82
2.69
4.32
2.41
3.80
2.18
3.41
1.73
2.68

Die Index

Yellow

L115

Black

23

Pink

L99

Brown

20

Blue

19 or
L80

Red

17

Yellow

16

Purple

15

Black

13

Pink

12

Brown

10

Wire Strip
Length
1.96
3.09
1.67
2.71
1.77
2.68
1.60
2.47
1.60
2.47
1.42
2.34
1.38
2.29
1.24
2.06
1.10
1.80
1.00
1.61
0.78
1.26

All connectors are UL486A Listed.


* Clear Heat shrink UL224 VW1 Listed passes
TELCORDIA GR-347-CORE Abrasion and Cut Test.
(Up to 750 kcmil Class B code cable. Contact factory for
750 flex cable applications.)

116

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YSR-TC
HYREDUCER
In-line Reducer Splice Kits for
Telecommunications
Applications
YSR-TC reducing splice kits provide for splicing two different cable sizes with inspection
holes. The larger conductor is inserted first
and butts against the center of the connector
where the smaller barrel begins. Constructed
from seamless, high conductivity electrolytic
copper tubing for maximum conductivity, and
tin plated to resist corrosion. The YSR-TC
family also features the BURNDY color code
system. Clear heat shrink kits.

Plastic
Bag/Kit

Connector
Wire Range
Barrel A
AWG

750 kcmil
FLEX

750 kcmil
CODE

500 kcmil
FLEX

500 kcmil
CODE

Barrel B
mm2

500 mm2
Class 5

300 mm2
Class 5

240 mm2
Class 2

AWG
750 Kcmil
CODE
500 Kcmil
CODE
500 Kcmil
FLEX
350 Kcmil
CODE
350 Kcmil
FLEX
4/0 AWG
FLEX
500 Kcmil
FLEX
350 Kcmil
CODE
350 Kcmil
FLEX
4/0 AWG
CODE
4/0 AWG
FLEX
350 Kcmil
CODE
350 Kcmil
FLEX
4/0 AWG
CODE
4/0 AWG
FLEX
350 Kcmil
CODE
350 Kcmil
FLEX
4/0 AWG
CODE

mm2

240 mm2
Class 2
300 mm2
Class 5
185 mm2
Class 2
240 mm2
Class 5

300 mm2
Class 5
185 mm2
Class 2
240 mm2
Class 5

185 mm2
Class 2
240 mm2
Class 5

185 mm2
Class 2
240 mm2
Class 5

All connectors are UL486A Listed.


* These kits were developed in conjuction with TYCO
ELECTRONICS, Power System Division and will have
TYCO markings on them.

** Clear
Heat Shrink Kit
Catalog Number
YSR44FX39LTCKITC
YSR44FX39TCKITC
YSR44FX34LTCKITC
YSR44FX34TCKITC
YSR44FX38FXLTEL46*
YSR44FX38FXTEL48*
YSR44FX31LTCKITC
YSR44FX31TCKITC
YSR44FX34FXLTEL30*
YSR44FX34FXTEL32*
YSR44FX29FXLTEL6*
YSR44FX29FXTEL8*
YSR3938FXLTEL42*
YSR3938FXTEL44*
YSR3931LTCKITC
YSR3931TCKITC
YSR3934FXLTEL26*
YSR3934FXTEL28*
YSR3928LTCKITC
YSR3928TCKITC
YSR3929FXLTEL2*
YSR3929FXTEL4*
YSR38FX31LTCKITC
YSR38FX31TCKITC
YSR38FX34FXLTEL38*
YSR38FX34FXTEL40*
YSR38FX28LTCKITC
YSR38FX28TCKITC
YSR38FX29FXLTEL14*
YSR38FX29FXTEL16*
YSR3431LTCKITC
YSR3431TCKITC
YSR3434FXLTEL34*
YSR3434FXTEL36*
YSR3428LTCKITC
YSR3428TCKITC

Dimensions
Barrel
Type
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long

Barrel A Barrel B
2.09
3.22
2.09
3.22
2.09
3.22
2.09
3.22
2.09
3.22
2.09
3.22
1.78
2.82
1.78
2.82
1.78
2.82
1.78
2.82
1.78
2.82
1.88
2.79
1.88
2.79
1.88
2.79
1.88
2.79
1.69
2.56
1.69
2.56
1.69
2.56

1.78
2.82
1.69
2.56
1.88
2.79
1.49
2.42
1.69
2.56
1.44
2.36
1.88
2.79
1.49
2.42
1.69
2.56
1.30
2.11
1.44
2.36
1.49
2.42
1.69
2.56
1.30
2.11
1.44
2.36
1.49
2.42
1.69
2.56
1.30
2.11

Provided with 2 heat shrink tubings. One will overlap the


other. Install the smaller first and larger second.

For CUSTOMER SERVICE call 1-800-346-4175

L
4.38
6.55
4.91
6.91
4.61
6.64
5.18
7.24
4.91
6.91
5.33
7.38
3.79
5.74
4.36
6.33
4.09
6.00
4.65
6.51
4.51
6.47
4.33
6.17
4.06
5.83
4.62
6.34
4.48
6.30
3.66
5.45
3.39
5.12
3.95
5.63

Wire Strip
Length
Color Code
Die Index
Barrel A Barrel B Barrel A Barrel B Barrel A Barrel B
Yellow

Black

L115

24

Yellow

Brown

L115

20

Yellow

Pink

L115

L99

Yellow

Red

L115

18

Yellow

Blue

L115

19 or
L80

Yellow

Yellow

L115

16

Black

Pink

24

L99

Black

Red

24

18

Black

Blue

24

19 or
L80

Black

Purple

24

15

Black

Yellow

24

16

Pink

Red

L99

18

Pink

Blue

L99

19 or
L80

Pink

Purple

L99

15

Pink

Yellow

L99

16

Brown

Red

20

18

Brown

Blue

20

19 or
L80

Brown

Purple

20

15

1.96
3.09
1.96
3.09
1.96
3.09
1.96
3.09
1.96
3.09
1.96
3.09
1.67
2.71
1.67
2.71
1.67
2.71
1.67
2.71
1.67
2.71
1.77
2.68
1.77
2.68
1.77
2.68
1.77
2.68
1.60
2.47
1.60
2.47
1.60
2.47

1.67
2.71
1.60
2.47
1.77
2.68
1.41
2.34
1.60
2.47
1.38
2.29
1.77
2.68
1.41
2.34
1.60
2.47
1.24
2.06
1.38
2.29
1.41
2.34
1.60
2.47
1.24
2.06
1.38
2.29
1.41
2.34
1.60
2.47
1.24
2.06

** Clear Heat shrink UL224 VW1 Listed passes


TELCORDIA GR-347-CORE Abrasion and Cut Test.
(Up to 750 kcmil Class B code cable. Contact factory for
750 flex cable applications.)

117

BURNDY
Telecommunications Products
TYPE YSR-TC
HYREDUCER
(Continued)
In-line Reducer Splice Kits for
Telecommunications
Applications

Plastic
Bag/Kit

Connector
Wire Range
Barrel A
AWG
500 kcmil
CODE

350 kcmil
FLEX

Barrel B
mm2

240 mm2
Class 2

240 mm2
Class 5

350 kcmil
CODE

185 mm2
Class 2

300 kcmil
FLEX

185 mm2
Class 5

4/0 AWG
FLEX

4/0 AWG
CODE

2/0 AWG
FLEX or CODE
1/0 AWG
FLEX or CODE
#2 AWG
FLEX or CODE
#4 AWG
FLEX or CODE

70 mm2
Class 5
50 mm2
Class 5
35 mm2
Class 5

AWG
4/0 AWG
FLEX
1/0 AWG
FLEX or CODE
4/0 AWG
FLEX
4/0 AWG
CODE
4/0 AWG
FLEX
1/0 AWG
CODE
4/0 AWG
CODE
4/0 AWG
FLEX
1/0 AWG
FLEX or CODE
#2 AWG
FLEX or CODE
4/0 AWG
FLEX
1/0 AWG
FLEX or CODE
#2 AWG
FLEX or CODE
1/0 AWG
FLEX or CODE
#2 AWG
FLEX or CODE
#6 AWG
FLEX or CODE
#6 AWG
FLEX or CODE
#6 AWG
FLEX or CODE
#6 AWG
FLEX or CODE
#6 AWG
FLEX or CODE

mm2

50 mm2
Class 5
120 mm2
Class 5 or Class 2

50 mm2
Class 5

50 mm2
Class 5
35 mm2
Class 5 or Class 2
120 mm2
Class 5 or Class 2
50 mm2
Class 5
35 mm2
Class 5 or Class 2
50 mm2
Class 5
35 mm2
Class 5 or Class 2
16 mm2
Class 5 or Class 2
16 mm2
Class 5 or Class 2
16 mm2
Class 5 or Class 2
16 mm2
Class 5 or Class 2
16 mm2
Class 5 or Class 2

All connectors are UL486A Listed.


* These kits were developed in conjuction with TYCO
ELECTRONICS, Power System Division and will have
TYCO markings on them.

118

** Clear
Heat Shrink Kit
Catalog Number
YSR3429FXLTEL10*
YSR3429FXTEL12*
YSR3425FXLTCKITC
YSR3425FXTCKITC
YSR34FX28FXLTCKITC
YSR34FX28FXTCKITC
YSR34FX28LTCKITC
YSR34FX28TCKITC
YSR34FX29FXLTEL22*
YSR34FX29FXTEL24*
YSR34FX25FXLTCKITC
YSR34FX25FXTCKITC
YSR3128LTCKITC
YSR3128TCKITC
YSR3129FXLTEL18*
YSR3129FXTEL20*
YSR3125FXLTCKITC
YSR3125FXTCKITC
YSR312CFXLTCKITC
YSR312CFXTCKITC
YSR32FX29FXLTCKITC
YSR32FX29FXTCKITC
YSR29FX25FXLTCKITC
YSR29FX25FXTCKITC
YSR29FX2CFXLTCKITC
YSR29FX2CFXTCKITC
YSR2825FXLTCKITC
YSR2825FXTCKITC
YSR282CFXLTCKITC
YSR282CFXTCKITC
YSR286CFXLTCKITC
YSR286CFXTCKITC
YSR26FX6CFXLTCKITC
YSR26FX6CFXTCKITC
YSR25FX6CFXLTCKITC
YSR25FX6CFXTCKITC
YSR2CFX6CFXLTCKITC
YSR2CFX6CFXTCKITC
YSR4CFX6CFXLTCKITC
YSR4CFX6CFXTCKITC

Dimensions
Barrel
Type
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long
Standard
Long

Barrel A Barrel B
1.69
2.56
1.69
2.56
1.69
2.56
1.69
2.56
1.69
2.56
1.69
2.56
1.49
2.42
1.49
2.42
1.49
2.42
1.49
2.42
1.57
2.48
1.44
2.36
1.44
2.36
1.30
2.11
1.30
2.11
1.30
2.11
1.16
1.85
1.04
1.66
0.82
1.29
0.74
1.18

1.44
2.36
1.04
1.66
1.43
2.56
1.30
2.56
1.44
2.36
1.04
1.66
1.30
2.56
1.44
2.36
1.04
1.66
0.82
1.29
1.43
2.56
1.04
1.66
0.82
1.29
1.04
1.66
0.82
1.29
0.73
1.15
0.73
1.15
0.73
1.15
0.73
1.15
0.73
1.15

Provided with 2 heat shrink tubings. One will overlap the


other. Install the smaller first and larger second.

L
3.81
5.59
4.01
5.50
3.86
5.86
3.95
6.07
3.81
5.59
4.01
5.50
3.27
5.46
3.13
4.97
3.33
4.88
3.37
4.78
3.46
5.51
3.10
4.63
3.13
4.53
2.66
4.09
2.70
3.99
2.99
4.23
2.71
3.83
2.42
3.45
1.93
2.82
1.67
2.53

Wire Strip
Length
Color Code
Die Index
Barrel A Barrel B Barrel A Barrel B Barrel A Barrel B
Brown

Yellow

Brown

Pink

20

16

20

12

19 or
L80
19 or
L80
19 or
L80
19 or
L80

Blue

Purple

15

Blue

Purple

Blue

Yellow

Blue

Pink

Red

Purple

18

15

Red

Yellow

18

16

Red

Pink

18

12

Red

Brown

18

10

Red

Yellow

18

16

Yellow

Pink

16

12

Yellow

Brown

16

10

Purple

Pink

15

12

Purple

Brown

15

10

Purple

Blue

15

Black

Blue

13

Pink

Blue

12

Brown

Blue

10

Gray

Blue

15
16
12

1.60
2.47
1.60
2.47
1.60
2.47
1.60
2.47
1.60
2.47
1.60
2.47
1.41
2.34
1.41
2.34
1.41
2.34
1.41
2.34
1.48
2.40
1.38
2.29
1.38
2.29
1.24
2.06
1.24
2.06
1.24
2.06
1.10
1.80
1.00
1.61
0.78
1.26
0.71
1.15

1.38
2.29
1.00
1.61
1.36
1.36
1.24
2.47
1.38
2.29
1.00
1.61
1.24
2.47
1.38
2.29
1.00
1.61
0.78
1.26
1.36
2.47
1.00
1.61
0.78
1.26
1.00
1.61
0.78
1.26
0.70
1.12
0.70
1.12
0.70
1.12
0.70
1.12
0.70
1.12

** Clear Heat shrink UL224 VW1 Listed passes


TELCORDIA GR-347-CORE Abrasion and Cut Test.
(Up to 750 kcmil Class B code cable. Contact factory for
750 flex cable applications.)

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YC-L

THIN-WALL COPPER C-TAP


UL Listed to 600 Volts
D

Type YC-L is a thin-wall high conductivity


copper connector for making copper tap and
parallel connections from #14 to 3/0 AWG.

Features and Benefits


Manufactured from high conductivity
wrought copper.
Provides low resistance and excellent
electrical conductivity.
Range-taking connector.
Lowers inventory requirements.
Reinforced ribs.
Provides maximum pull-out values.
Compact size.
Easy to tape and insulate connection.
Economical.
Provides low installed cost.

RIBS

INSTALLATION TOOLING

CATALOG
NUMBER
YC10L12
YC8L12
YC6L12
YC4L12
YC3L12
YC2L12

YC1L12

YC25L12

YC26L12

YC27L12

ACCOMMODATES
RUN
TAP
14
16-14
12
16-14
10
14
10
10
8
12
8
10-8
6
12-10
6
8-6
5,4
12-8
5,4
6-5
3
12-6
4
4
3
5
2
12-6
3
4-3
2
5-4
1
12-5
2 Str.
2 Str. 2 Sol.
2 Sol.
3 Str. 3 Sol.
1 Str.
4 Str. 4 Sol.
1 Sol.
3 Str. 3 Sol.
1/0 Str. 12 Str. 12 Sol.
1/0 Sol. - 4 Str. 4 Sol.
1
2-1
1/0
3-2
2/0
12-3
1/0
1-1/0
2/0
2-1
3/0
12-2

NO.
OF
RIBS

DIMENSIONS
C
D

.18
[4.6]

.11
[2.8]

.40
[10.2]

.060
[1.65]

.25
[6.4]
.33
[8.4]
.38
[9.7]
.48
[11.4]

.21
[3.8]
.25
[5.1]
.28
[6.1]
.37
[6.4]

.60
[15.2]
.60
[15.2]
1.18
[30.2]
1.18
[30.2]

.072
[1.83]
.072
[1.83]
.072
[1.83]
.081
[2.06]

.50
[12.7]

.36
[7.6]

1.18
[30.2]

.56
[14.2]

.45
[8.6]

.62
[15.7]

0
0
0
1
1

COLOR
CODE
Red
Blue
Gray
Brown

MECHANICAL
MD6, OUR840 &
MD7-34R
DIE NO.
Y2MR
(# CRIMPS)
Red
(1)

W8CVT
(1)

Blue
(1)
Gray
(2)
Brown
(2)

W5CVT
(1)
W4CVT
(1)
W2CVT
(2)
W1CVT
(2)

DIE
INDEX
EMBOSSMENT

BCT500,
Y500CT,
BAT500
(# Crimps)

HYDRAULIC
Y35,Y39,
Y750,Y45
Y46*
(# Crimps)

DIE
INDEX
WIRE
EMBOSS- STRIP
MENT
LENGTH

49
7

3/8

WC4
(1)

UC4
(1)

8
10

5/8
5/8

10M

11

1-3/16

Green

1-3/16

.081
[2.06]

Pink

W25VT
(2)

12

WC2
(1)

UC2
(1)

12M

1-3/16

1.75
[44.4]

.081
[2.06]

Black

W26VT
(3)

13

WC1
(2)

UC1
(1)

13M

1-13/16

.50
[9.6]

1.75
[44.4]

.090
[2.29]

Orange

W27VT
(3)

14

WC25
(2)

UC25
(1)

14M

1-13/16

.69
.53
[17.5] [10.7]

1.75
[44.4]

.090
[2.29]

Purple

W28VT
(3)

15

.81
.54
[20.6] [11.9]

1.75
[44.4]

.090
[2.29]

Yellow

W29VT
(3)

16

1-13/16

1-13/16

See tooling section of this catalog for complete tool and die
listings.
* Use PUADP-1 adapter with U dies in Y46 HYPRESS
For Tin plating add TN suffix (example = YC10L12TN)

For CUSTOMER SERVICE call 1-800-346-4175

119

BURNDY
Telecommunications Products
TYPE YCHC
C-TAP COPPER CRIMPIT

90 C

Features and Benefits


Wide range of run/tap combinations including Class B code I and locomotive flexible
conductor combinations. All (B/B, B/I, I/I)
combinations are recommended.
Each connector accommodates many
cable combinations, allowing maximum
flexibility for the design and installation of
a system.
Color-coded on the connector that
matches the die.
Provides matched system for fast and
easy installation.

BURNDY
CATALOG
NUMBER

FLAME
RETARDANT
COVER
CAT. NO.

YCHC44TC44

CFR-FR

YCHC39TC39

CFR-FR

YCHC39TC31

CFR-FR

YCHC39TC2

CFR-FR

YCHC34TC34

CFN-FR

YCHC34TC29

CFN-FR

YCHC34TC2

CFN-FR

YCHC29TC29

CFD-FR

YCHC29TC2

CFD-FR

YCHC2TC2

CFO-FR

YCHC8TC8

CONDUCTOR SIZES CODE/(FLEX) CABLE


MAIN

TAP 1

1000-750
(750-500)
750-500
(550-500)
750-500
(550-500)
750-500
(550-500)
500-4/0
(350-4/0)
500-4/0
(350-4/0)
500-4/0
(350-4/0)
250-2
(4/0-2)
250-2
(4/0-2)
2-6 STR./SOL.
(2-8)
8-14
(8-14)

1000-750
(750-500)
750-350
(550-350)
350-2
(250-2)
2-6 STR./SOL.
(2-8)
500-4/0
(350-4/0)
250-2
(4/0-2)
2-6 STR./SOL.
(2-8)
250-2
(4/0-2)
2-6 STR./SOL.
(2-8)
2-6 STR./SOL.
(2-8)
8-14
(8-14)

NOTE: To properly use tap 2 and/or tap 3 conductors in YCHC


connector, a conductor from the tap 1 cable range must be
included in the tap 1 groove.
To obtain covers made of polyethylene remove suffix-FR
(example: CFO). CFO is not flame retardant.
* Use PUADP-1 adaptor with "U" dies in Y46.

120

TAP 2

Each connector has a recommended


insulating cover available. Flame retardant
type CF-FR covers meet oxygen index
28 and UL94 V-O requirements.
A complete insulated UL listed installation is provided.
Die index embossed on connector after
completion of crimp.
Permanent inspectability of installed
connector ensures consistently reliable
and dependable connections.

TOOLING ( NO. OF CRIMPS)


COLOR DIE INDEX &
TAP 3 Y35 Y750 Y46* CODE EMBOSSMENT

STRIP
LENGTH

P1102 1

White

1102

3.59

1.73 1.16

1-1/4

P1103 1

Blue

1103

3.12

1.53 1.06

1-1/8

2-6 STR./SOL.
(2-8)
8-14
(8-14)

8-14
(8-14)

P1103 1

Blue

1103

2.96

1.53 1.31

1-3/8

P1103 1

Blue

1103

2.66

1.53 1.31

1-3/8

U1104

P1104 1

Brown

1104

2.97

1.38 1.16

1-1/4

U1104

P1104 1

Brown

1104

2.45

1.26

.94

1

U1104

P1104 1

Brown

1104

2.45

1.26

.94

1

U997

U997

Orange

997

2.12

.98

.94

1

U251

U251

Red

251

1.78

.97

.81

1

U-C

U-C

U-C

Brown

1.22

.60

.81

1

U-240

Red

240

.53

.35

.56

5/8

2-6 STR./SOL.
(2-8)
8-14
(8-14)

8-14
(8-14)
8-14
(8-14)

U-240 1

U-240 1

See tooling section of Master Catalog for complete tool


and die listings.
For applications requiring flame retardant cover, use
CFBG-FR cover and YH8C8C connector by ordering
YH8C8CWC.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YH

COLOR CODE
DIE AND
CRIMP
INFORMATION

H-TAP COPPER CRIMPIT

ELECTRO-TIN
PLATED

Fig. 1
CONDUCTOR
RANGE

Features and Benefits


Accommodates a wide range of run/tap
copper cable combinations including both
flexible and code combinations. All (B/B,
B/I, I/B, I/I) combinations acceptable.
Each connector has many copper cable
combination applications allowing maximum flexibility for the design and installation of a system.
Tap grooves function independently of
each other. Use of one tap is required.
Balance may be used or left empty.
Provides maximum design and installation flexibility.
Color code on the connector matches
installation die.
Provides matched system for fast and
easy installation.
Die index embossed on connector after
completion of crimp.
Permanent inspectability of installed
connectors to ensure consistently
reliable and dependable connections.

THIRD HAND

PATENTED

Fig. 2

Fig. 3

Recommended flame retardant type CFFR insulating covers meet oxygen index
28 and UL94 V-O requirements.
A complete insulated UL listed installation is provided.
Third Hand constrains conductors while
installer completes crimp. Included with
each connector.
Simplifies installation, reducing
installed cost.

Fig. 4

Fig. 5

TABLE 1 CODE CONDUCTOR AND METRIC EQUIVALENT


Kit
Catalog
Number *

H-Tap
Connector

YH4444WC

YH4444

YH4434WC

YH4434

YH4429WC

Components
Flame Retardant Cover
Clear
Black

Fig. #

CCFR-FR

CFR-FR

YH4429

CCFR-FR

CFR-FR

YH3939WC

YH3939

CCFR-FR

CFR-FR

YH3931WC

YH3931

CCFR-FR

CFR-FR

YH3434WC

YH3434

CCFN-FR

CFN-FR

YH3429WC

YH3429

CCFN-FR

CFN-FR

YH2929WC

YH2929

CCFD-FR

CFD-FR

YH292CWC

YH292C

CCFD-FR

CFD-FR

YH298CWC

YH298C

CCFD-FR

CFD-FR

YH2C2CWC

YH2C2C

CCFO-FR

CFO-FR

YH6C6CWC

YH6C6C

CCFBG-FR

CFBG-FR

YH8C8CWC

YH8C8C

CCFBG-FR

CFBG-FR

* NOTE: To obtain connector and cover packaged together,


add suffix "-WC" to connector catalog number (example:
YH2929-WC includes (1) YH2929 and (1) CFD-FR in a
polybag).
Use PUADP-1 adaptor with "U" dies in Y46.

Conductor Sizes Code/(Flex Cable)


Main
Tap 1
Tap 2
Tap 3
1000-750
1000-750
(750-500)
(750-500)

(750)
(350)
1000-750
250-2

(777-500)
(4/0-2)
750-500
750-350

(550-500)
(550-350)
750-350
4/0-1/0
1-6 STR/SOL 2-14
(550-500)
(250-1/0)
(1-8)
(2-14)
500-250
500-4/0

(350-4/0)
(350-4/0)
500-4/0
250/1/0
1-6 STR/SOL 8-14
(350-4/0)
(4/0-1/0)
(1-8)
#8
250-2
250-2

(4/0-2)
(4/0-2)
250-2
2-6 STR/SOL
8-14

(4/0-2)
(2-8)
(8-14)
250-2
8-14
8-14

(4/0-2)
(8-14)
(8-14)
2-6 STR/SOL 2-6 STR/SOL
8-14
8-14
(2-8)
(2-8)
(8-14)
(8-14)
6-10
6-14

(6-10)
(6-14)
8-14
8-14

(8-14)
(8-14)

To obtain covers made of polyethylene remove suffix -FR


(example: CFO) CFO is not flame retardant.
See tooling section of this catalog for complete tool and die
listings.

For CUSTOMER SERVICE call 1-800-346-4175

Metric Conductor Sizes (mm2)


Main
Tap 1
Tap 2 Tap 3
500-400

500-400

500-400

150-35

300-300

300-185

300-185

95-70

35-16

35-2.5

240-150

240-120

240-120

120-70

35-16

6-2.5

120-35

120-35

120-35

35-16

6-2.5

120-35

6-2.5

6-2.5

35-16

35-16

6-2.5

6-2.5

10-6

10-2.5

6-2.5

6-2.5

Use CFN-FR for single tap installation and CFR-FR for


multiple tap installation

750 Flex, main, is the only wire that may be used with a
350 FLEX TAP in the YH4444 connector.

121

BURNDY
Telecommunications Products
TYPE YH
H-TAP COPPER CRIMPIT
(Continued)

COLOR CODE
DIE AND
CRIMP
INFORMATION

ELECTRO-TIN
PLATED

CONDUCTOR
RANGE

THIRD HAND

TABLE 2 FLEX AND METRIC CONDUCTOR RANGES

CATALOG
NUMBER
YH4444

YH4429
YH3939

YH3931

YH3434

YH3429

YH2929
YH292C

YH298C

YH2C2C

YH6C6C
YH8C8C

Main
Tap 1
Main
Tap 1
Main
Tap 1
Main
Tap 1
Main
Tap1
Tap 2
Tap 3
Main
Tap 1
Main
Tap 1
Tap 2
Tap 3
Main
Tap 1
Main
Tap1
Tap 2
Main
Tap1
Tap 2
Main
Tap 1
Tap 2
Tap 3
Main
Tap 1
Main
Tap 1

MAXIMUM
CONDUCTOR IN
RANGE
FLEX
CONDUCTOR
(AWG/kcmil)
777
777
777

777
4/0
550
550
550
250
1
2
350
350
350
4/0
1
8
4/0
4/0
4/0
2
8
4/0
8
8
2
2
8
8
6
6
8
8

Use CFN-FR for single tap installation and CFR-FR for multiple tap installation
Use PUADP-1 adaptor with "U" dies in Y46
NOTE: To obtain connector and cover packaged together, add
suffix "-WC" to connector catalog number.
Example: YH2929-WC includes (1) YH2929 and (1) CFDFR in a polybag.

122

MAXIMUM METRIC
DIMENSIONS
mm2
393
393
393

393
107
278
278
278
126
42
33.6
177
177
177
107
42
8
107
107
107
33.6
8
107
8
8
33.6
33.6
8
8
13
13
8
8

DIAMETER
mm
28
28
28

28
15.5
25
25
25
17
9
8
20
20
20
15.5
9
4
15.5
15.5
15.5
8
4
15.5
4
4
8
8
4
4
5
5
4
4

MINIMUM
CONDUCTOR IN
RANGE
FLEX
CONDUCTOR
(AWG/kcmil)
500
500
750
350
500
2
500
350
500
1/0
8
14
4/0
4/0
4/0
1/0
8
14
2
2
2
8
14
2
14
14
8
8
14
14
10
14
14
14

MINIMUM METRIC
DIMENSIONS
mm2
253
253
380
177
253
33.6
253
177
253
53.5
8
2
107
107
107
53
8
2
33.6
33.6
33.6
8
2
33.6
2
2
8
8
2
2
5
2
2
2

DIAMETER
mm
24
24
31
20
24
8
24
20
24
11
4
2
15.5
15.5
15.5
11
4
2
8
8
8
4
2
8
2
2
4
4
2
2
3
2
2
2

To obtain covers made of polyethylene remove suffix -FR


(ex. CFO) CFO is not flame retardant.
See tooling section of this catalog for complete tool and
die listings.
* Will accommodate 750 Flex (Main) to 350 Flex (TAPI)
Please consult factory regarding UL listings with metric
conductor.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YH

COLOR CODE
DIE AND
CRIMP
INFORMATION

H-TAP COPPER CRIMPIT


(Continued)

ELECTRO-TIN
PLATED

Fig. 1
CONDUCTOR
RANGE

THIRD HAND

Fig. 2

Fig. 4

Fig. 3

Fig. 5

TABLE 3 INSTALLATION TOOLING + DIMENSIONS


Tooling ( No. of Crimps)
Catalog
Number
YH4444
YH4434
YH4429
YH3939
YH3931

Flame Retardant Cover


Clear
Black

Fig. No.

Y35

Y750

Y46*

Color Die Index &


Code Embossment

P1102

White

1102

3.38

1.70 1.00

1-1/8

PYFR
PYFR
PYFR
P1104
U1104M
P1104
U1104M
U654
P654
U654
P654
U654
P654
U-C
UBGRT
U11T-1

1
1
1

Yellow
Yellow
Yellow

K-R
K-R
K-R

3.22
2.97
2.97

1.70 1.00
1.50 1.25
1.50 .95

1-3/8
1-3/8
1-1/16

Brown

1104

2.43

1.15 1.00

1-1/8

Brown

1104

2.23

1.31 1.00

1-1/8

Purple

654

1.85

.90

.90

1-1/16

Purple

654

1.52

.90

.90

1-1/16

Purple

654

1.52

.90

.90

1-1/16

1
1
1

Brown
Orange
Green

C
BG
11

1.25
.81
.63

.60
.39
.40

.75
.60
.60

7/8
3/4
3/4

CCFR-FR

CFR-FR

CCFR-FR
CCFR-FR
CCFR-FR

CFR-FR
CFR-FR
CFR-FR

5
1
2

YH3434

CCFN-FR

CFN-FR

YH3429

CCFN-FR

CFN-FR

U1104M
U1104
U1104M
U1104

1
2
1
2

YH2929

CCFD-FR

CFD-FR

U654

YH292C

CCFD-FR

CFD-FR

U654

YH298C

CCFD-FR

CFD-FR

U654

YH2C2C
YH6C6C
YH8C8C

CCFO-FR
CCFBG-FR
CCFBG-FR

CFO-FR
CFBG-FR
CFBG-FR

4
1
1

U-C
UBGRT
U11T-1

1
1
1

U-C
UBGRT
U11T-1

1
1
1

Use CFN-FR for single tap installation and CFR-FR for


multiple tap installation
* Use PUADP-1 adaptor with "U" dies in Y46
NOTE: To obtain connector and cover packaged together, add
suffix "-WC" to connector catalog number (example:
YH2929-WC includes (1) YH2929 and (1) CFD-FR in a
polybag).

Strip
Length

To obtain covers made of polyethylene remove suffix -FR


(example: CFO) CFO is not flame retardant.
See tooling section of this catalog for complete tool and
die listings.

For CUSTOMER SERVICE call 1-800-346-4175

123

BURNDY
Telecommunications Products
TYPE CF-FR
H-TAP
FLAME RETARDANT COVER
UL Listed to 600 Volts

Features and Benefits

600 VOLT 90 C

One-piece design.
No extra parts or hardware required.
Slips over connector and latches
securely shut.
Fast, easy, reliable insulation of
H-Tap compression connectors.
Eliminates taping.
Economical, fast, easy installation.

CATALOG
NUMBER

MAX. CONDUCTOR
ACCOMMODATED

MATCHED H COPPER CRIMPIT

#8 AWG
#6 AWG
#2 AWG
250 kcmil
500 kcmil
750 kcmil
1000 kcmil

YH8C8C
YH6C6C
YH2C2C
YH292C, YH298C, YH2929
YH3434, YH3429*
YH3939, YH3931, YH4429
YH4434 ,YH4444

CFBG-FR
CFO-FR
CFD-FR
CFN-FR
CFR-FR

Flash barriers.
Protects against electrical flashover.
CF-FR flame retardant design.
Self-extinguishing retardant properties.
Minimum 28 oxygen index.
Self-extinguishing retardant properties.
UL 94 V-O rated.
Self-extinguishing retardant properties.

MAX. CONNECTOR
LENGTH

CONNECTOR
COLOR CODE

.80
.95
1.10
1.30
1.10

Green
Orange
Brown
Purple
Brown
Yellow
White

MAX. CONNECTOR
LENGTH

CONNECTOR
COLOR CODE

.65

* Use CFR-FR WHEN MULTIPLE TAPS ARE USED.


Two-piece design packaged together.

TYPE CCF-FR
CLEAR H-TAP
FLAME RETARDANT COVER
UL Listed to 600 Volts

Coming Soon

600 VOLT 90 C
CATALOG
NUMBER
CCFBG-FR
CCFO-FR
CCFD-FR
CCFN-FR
CCFR-FR

MAX. CONDUCTOR
ACCOMMODATED

MATCHED H COPPER CRIMPIT

#8 AWG
#6 AWG
#2 AWG
250 kcmil
500 kcmil
750 kcmil
1000 kcmil

YH8C8C
YH6C6C
YH2C2C
YH292C, YH298C, YH2929
YH3434, YH3429*
YH3939, YH3931, YH4429
YH4434, YH4444

.65
.80
.95
1.10
1.30
1.10

Green
Orange
Brown
Purple
Brown
Yellow
White

* Use CCFR-FR WHEN MULTIPLE TAPS ARE USED.


Two-piece design packaged together.

124

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE PP & YP
QikPwr
SEPARABLE POWER
CONNECTORS
QikPwr Separable Power Connectors are
designed to allow for quickly mating and
unmating two-pole applications. Available for
use in 50, 175, and 350 Amp applications.
Rated for up to 600 volt continuous AC or DC
operations. Each contact is silver-plated to
ensure high conductivity. Housings are
UL94VO rated.
For sizes and colors not shown, contact our
world class customer service department.

Kits: Contacts & Housing Packaged Together


CATALOG NUMBER
YPK14SV50GRY
YPK10SV50GRY
YPK8CSV50GRY
YPK6CSV50GRY
YPK1CSV175GRY
YPK25SV175GRY
YPK26SV350BLU
YPK26SV350GRY

AMPS

HOUSING
QTY. = 1

CONTACT
QTY. = 2

35
50
50
50
175
175
350
350

PPH50GRY
PPH50GRY
PPH50GRY
PPH50GRY
PPH175GRY
PPH175GRY
PPH350BLU
PPH350GRY

YPP14SV50
YPP10SV50
YPP8CSV50
YPP6CSV50
YPP1CSV175
YPP25SV175
YPP26SV350
YPP26SV350

Standard packaging = 1 housing and 2 contacts in bag.


Bulk packaging available, contact factory.
Customer specific kits available, contact factory.

Housings
CATALOG NUMBER
PPH50BLK
PPH50GRY
PPH50RED
PPH175GRY
PPH350BLU
PPH350GRY

AMPS

COLOR

50
50
50
175
350
350

Black
Gray
Red
Gray
Blue
Gray

Standard packaging = 1 per box.


Bulk packaging available, contact factory.
Other colors/amperages available upon request, contact factory.

Contacts
CATALOG NUMBER
YPP14SV50
YPP10SV50
YPP8CSV50
YPP6CSV50
YPP1CSV175*
YPP25SV175*
YPP26SV350

AMPS
35
50
50
50
175
175
350

CONDUCTOR
AWG & FLEX CU
METRIC
#14 AWG & FLEX
#12-10 AWG & FLEX
#8 AWG & FLEX
#6 AWG & FLEX
#1 AWG & FLEX
1/0 AWG & FLEX
2/0 AWG & FLEX

Standard packaging = 2 per bag.


Bulk packaging available, contact factory.
Other conductor/amperage sizes available upon request,
contact factory.

2.5 mm2
4-6 mm2
10 mm2
16 mm2
50 mm2
50 mm2
70 mm2

INSTALLATION TOOLING

Y1MR-TC, Y1MR, & Y2MR


U1CRT, W1CRT & W1CVT Dies
U26RT, W26RT, & W26VT Dies

COLOR
CODE

DIE INDEX
(# OF CRIMPS)

Red

49 (2)

Blue

7 (2)

Green

11 (1)

Black

13 (1)

* Y1MR and Y1MRTC tools are not specified for use with this
connector.

For CUSTOMER SERVICE call 1-800-346-4175

125

BURNDY
Telecommunications Products

126

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
THE HYGROUND
IRREVERSIBLE
COMPRESSION
SYSTEM
Features and Benefits
Irreversible compression.
Meets NEC code, section 250-81 and
250-91.
Material pure wrought copper extrusions,
rod and seamless tubing identical
material to the conductor.
Completely eliminates the possibility of
corrosion due to dissimilar metals.
Heavy duty connector design.
All connectors will carry the equivalent
or greater current carrying capacity
of the conductor while maintaining
high mechanical strength and
electrical integrity.
Range taking design minimum number of
connector combinations required to install
a conductor range of #6 solid to 500 kcmil
plus 1/2", 5/8", 3/4", and 1" ground rods
and rebar.
Inventories are kept to a minimum and
product selection is simplified.
System engineered tooling.
Each tooling recommendation has
been designed to ensure reliability
of the connection.
Compression connectors can be installed
in all kinds of weather.
Eliminates costly construction delays and
enables the installer to better schedule
their job.

May be installed without special training


or special tools. Y750 crimps entire range.
Low installed cost.
Simplified installation.
Each connection can be made in less
than 3 minutes.
Low installed cost
Simplified installation.
Non-hazardous process installation. Does
not produce heat or dangerous particles.
Safe.
No need for special protective equipment
or clothing.
Each connector is clearly marked with
catalog number, conductor size and
installation die information.
Easy and accurate identification.
Inspection ports are provided to assure
proper insertion of the conductor.
Built-in quality assurance.
The die index number is embossed on the
connector after completion of the crimp.
Facilitates speedy inspection of installed
connectors to ensure consistently
reliable and sound connections.
Most HYGROUND irreversible compression elements are prefilled with
PENETROX and individually sealed
in clear polyethylene sheet.
Ensures that all contact surfaces are in
the proper condition for installation.
Ensures the electrical integrity of the
finished connection by inhibiting moisture
and contaminates from entering the
contact area.

For CUSTOMER SERVICE call 1-800-346-4175

All HYGROUND irreversible compression connectors are listed in conformance


with Underwriters Laboratories Standard
UL467 and conform to applicable sections
of the National Electrical Code.
May be used in direct burial or concrete
imbedded grounding applications.
All HYGROUND connectors (with the
exception of type YGA & YGS) have
been tested successfully according to
requirements of Standard IEEE 837
latest revision.
Meets tough industry performance
requirements.
Ground Rod Connections can withstand
power installation and retain IEEE, and
UL performance.
UPRECRIMP dies give added
mechanical strength. UPRECRIMP 34
for 3/4" rod, UPRECRIMP 12 for 1/2"
rod, and UPRECRIMP58 for 5/8" rod
(now includes undersized U.S. marketplace rods).
Allows connection to most sizes of
structural steel with no drilling, tapping,
or welding
Safely installed as low cost hot work
permits are not required to install in
hazardous areas.

127

BURNDY
Telecommunications Products
TYPICAL WIRELESS
COMMUNICATIONS
GROUND RING
USING THE
HYGROUND
GAR-TC
IRREVERSIBLE
Pg. 154
COMPRESSION
SYSTEM

YGHA
Pg. 139

YG-B
Pg. 144

YGIB
Pg. 142

YGHC-C
Pg. 134

YGHP-C
Pg. 132
KSU
Pg. 150
128

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

YGHA
Pg. 139

YC-L
Pg. 119

YGHP-C
Pg. 132

KS-DB
Pg. 149

YC-L
Pg. 119

YGL-C
Pg. 137

YGS
Pg. 141

For CUSTOMER SERVICE call 1-800-346-4175

GD
Pg. 155

GG
Pg. 157

B
Pg. 158
129

BURNDY
Telecommunications Products
TYPICAL
COMMUNICATIONS
INSIDE PLANT

YC-L
Pg. 119

YH
Pg. 121

YGHA
Pg. 139

YG-B
Pg. 144

YGIB
Pg. 142

YGC
Pg. 135

YGHP-C
Pg. 133

130

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products

GAR-BU
Pg. 153

YAG-LD
Pg. 57

GAR-TC
Pg. 154

YGHR-C
Pg. 138

GP-RT
Pg. 161

YGHP-C
Pg. 132

For CUSTOMER SERVICE call 1-800-346-4175

131

BURNDY
Telecommunications Products
TYPE YGHP-C

PREFILLED WITH
PENETROX-E

HYTAP CONNECTOR

THIRD HAND

TAP (B)

High Strength
Copper Irreversible
Compression
DIE INDEX
AND CONDUCTOR
INFORMATION

Ground Rod Tap


Connector

TAP (A)

PATENTED

Type YGHP-C irreversible compression


ground tap figure 6 can be used as a ground
rod tap connector for both continuous run and
tapping applications. An open groove allows
ground rod to be connected to a continuous
run or tap. The second groove is for a tap
only. Prefilled with PENETROX-E and strip
sealed. UL467 Listed for direct burial in earth
or concrete.
MEETS ALL

IEEE

837 REQUIREMENTS

Features and Benefits


Tap (A) accepts a continuous run on
tap conductor.
Tap (B) accepts a tap conductor only.
One connector style can be used for
many applications, reducing number
of connectors in inventory.
Material is high conductivity wrought
copper extrusion, identical material to
the conductor.
High-conductivity copper minimizes
resistance and voltage drop. Eliminates
the possibility of corrosion due to
dissimiliar metals.
System engineered tooling.
The tooling recommendation has been
designed to ensure a reliable, dependable connection every time.
The die index number is embossed on
conductor after completion of crimp.
Facilitates speedy inspection of installed
connectors to ensure consistently
reliable and dependable connections.

Prefilled with PENETROX and individually sealed in clear polyethylene sheet.


Ensures the electrical integrity of the
finished connection by inhibiting moisture
and contaminates from entering the
contact area. Maintains long-term
high-conductivity.
UL467 Listed.
May be used in direct burial or concrete
embedded grounding applications.
Provides quality assurance to recognized
industry NEC standards from an
independent party.
Third Hand constrains conductors while
installer completes crimp. Included with
each connector.
Simplifies installation, reducing
installed cost.

CONTINUOUS RUN

CONTINUOUS RUN AND TAP

SINGLE TAP

INSTALLATION TOOLING
Y35/Y750
Y46
CATALOG
NUMBER

GROUND
ROD DIA.

YGHP58C2W-2
YGHP58C2W-2TN

1/2 - 5/8

#2 Sol. - #6 Sol. Copper


(1) Continuous run and (1) tap or
up to (2) taps may be connected.

1.90

NOTE: A 12" bend radius is recommended for the conductor.


Use PUADP-1 with U-dies in Y46.
See tooling section in Master Catalog for complete tool and
die listing.
+ Either tap position may be left void when fewer than (2)
conductors are used.

132

DIMENSIONS
L
W

TAP CONDUCTOR +

.75

.94

DIE
NO.

NO. OF
CRIMPS

DIE
NO.

NO. OF
CRIMPS

DIE
INDEX

U997

(1)

U997

(1)

997

Ground rod must be precrimped with die U2CABT (Index


No. 348).
For even greater rotational resistance use UPRECRIMP die.
For Galvanized Steel Rods order YGHP58C2W-2TN.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YGHP-C
HYTAP CONNECTOR
Irreversible compression ground tap figure 6
can be used as a tap connector or as a tap
splice connector. Four die sets and eight connectors can accommodate a conductor range
from #8 solid through 500 kcmil plus 1/2",
5/8", and 3/4" copper bonded ground rods.
UL467 Listed. Acceptable for direct burial in
earth and concrete. Prefilled with PENETROX compound and strip sealed.

UL96 Listed for Lightning Protection.

MEETS ALL

IEEE

837 REQUIREMENTS

467

Fig. 1

96

CATALOG
NUMBER

FIG.
NO.

YGHP2C2

YGHP2C6W6W

YGHP29C6W6W

YGHP29C2

YGHP29C26

YGHP29C29

YGHP34C2

YGHP34C26

YGHP34C29
YGHP34C34

1
1

ACCOMMODATES
RUN
TAP
#6 SOL. (0.162) {59500} #6 SOL. (0.162) {#2 STR.}
#2 STR. (0.292) {59500}
#2 STR. (0.292) {#2 STR.}
#6 SOL. (0.162)
#8 SIK. (0.128)
#2 STR. (0.292)
6 STR. (0.184) QTY. 2
#8 SOL. (0.128)
6 STR. (0.184) QTY. 2
#4 SOL. (0.204) {#4 SOL.}
1/0 STR. (0.372) {98500}
#2 STR. (0.292) {#2 STR.}
250 kcmil (0.575) {131500}
1/0 STR. (0.372) {98500}
1/2" 5/8" ROD
2/0 STR. (0.419) {98500}
3/0 STR. (0.470) {131500}
250 kcmil (0.575) {211500}
#4 SOL. (0.204)
#2 STR. (0.292)
250 kcmil (0.575) {250 kcmil}
1/0 STR. (0.372) {98500}
500 kcmil (0.813) {500 kcmil}
2/0 STR. (0.419) {98500}
5/8" 3/4" ROD
3/0 STR. (0.470) {131500}
250 kcmil (0.575) {211500}
250 kcmil (0.575)
350 kcmil (0.681)
500 kcmil (0.813)
500 kcmil (0.843)
5/8" 3/4" ROD

CABLE TO REBAR
RUN
TAP

#3 REBAR
3/8

#5 REBAR
5/8

INSTALLATION DATA
DIE Y750/Y35

INDEX
Y39
Y45
Y46
NO. OF
B NO. HYPRESS PAT750-18V HYPRESS HYPRESS CRIMPS
0

U0

U0

U0

U0

997

U997

U997P

U997

U997

998

PU998

PU998

PU998 or
S998

PU998 or
P998

U1011

S1011

P1011

#8 SOL. 6 STR.
#2 STR.

THRU
1/2
#4 REBAR

Fig. 2

1/0 STR. 2/0 STR.

.75
[19]

3/0 STR. 250 kcmil

1/0 STR. 2/0 STR.

THRU
3/0 STR. 250 kcmil
3/4
#6 REBAR 350 kcmil 500 kcmil

1.10
1011 U1011
[28]

Dimensions in brackets { } represent lightning protection


conductors.
NOTES:

When using #6 Sol. in tap, fold conductor double to improve

Clean rust and protective coatings from rebar before con-

fill in YGHP2C2.
For YGHP29C29 when using 3/0 in tap, minimum run
conductor is 2/0 STR.
Where a 'U' or 'PU' die is recommended with the Y45
HYPRESS, a PT6515 adapter must be used.
Where a 'U' or 'PU' die is recommended with the Y46
HYPRESS, a P-UADP-1 adapter must be used.

nector installation to provide a proper ground connection.


Precrimping is not required.
These connectors can only be installed using the Y750, Y45
or Y46 HYPRESS with the recommended dies. These
connectors can not be installed with the Y35 and Y39
HYPRESS.
Polarized die for the PAT750-18V.

Not UL96/CSA.

GROUND ROD
DIA.
1/2
5/8
3/4

UPRECRIMP DIES
UPRECRIMP 12
UPRECRIMP 58
UPRECRIMP 34

U2CABT

For increased rotational resistance on ground rods,


precrimp ground rod with U2CABT die Index 348 or
UPRECRIMP dies may be used for even greater
rotation and vibration resistance on ground rods.

CABLE TO GROUND ROD


CABLE TO REBAR
CABLE TO CABLE
FOR CONCRETE ENCASED
ELECTRODE GROUNDING
APPLICATIONS
For CUSTOMER SERVICE call 1-800-346-4175

133

BURNDY
Telecommunications Products
TYPE YGHC-C
HYTAP CONNECTOR
Irreversible compression ground tap figure
"C" connectors. Accommodates all cable
combinations from #6 solid through 500
kcmil. "C"- shaped opening permits placing
two continuous parallel cables into conductor
groove. UL 467 Listed. Acceptable for direct
burial in earth or concrete. Prefilled with
PENETROX compound and strip sealed.

UL96 Listed for Lightning Protection.

MEETS ALL

IEEE

837 REQUIREMENTS

467

96

COMMERCIAL COPPER
STRANDED COPPER
CATALOG
CABLE RANGE
CABLE RANGE
NUMBER
RUN
TAP
RUN
TAP
#6 SOL. (0.162) #6 SOL. (0.162) 10 mm2 (4.12 mm) 10 mm2 (4.12 mm)
YGHC2C2
#2 STR. (0.292) #2 STR. (0.292) 35 mm2 (7.62 mm) 35 mm2 (7.62 mm)
1 STR. (0.328) #6 SOL. (0.162)
35 mm2 (7.62 mm) 10 mm2 (4.12 mm)
{98500}
{#6 SOL.}
YGHC26C2
2/0 STR. (0.419)
#2 STR. (0.292)
70 mm2 (10.9 mm) 35 mm2 (7.62 mm)
{98500}
{#2 STR.}
1 STR. (0.328)
1 STR. (0.328)
35 mm2 (7.62 mm) 35 mm2 (7.62 mm)
{98500}
{98500}
YGHC26C26
2/0 STR. (0.419) 2/0 STR. (0.419)
70 mm2 (10.9 mm) 70 mm2 (10.9 mm)
{98500}
{98500}
3/0 STR. (0.470) 6 SOL. (0.419)
95 mm2 (12.5 mm) 10 mm2 (4.12 mm)
{3/0 STR.}
{59500}
YGHC29C26
250 kcmil (0.575) 2/0 STR. (0.419)
120 mm2 (14.4 mm) 70 mm2 (10.9 mm)
{250 kcmil}
{98500}
3/0 STR. (0.470) 3/0 STR. (0.470) 95 mm2 (12.5 mm) 95 mm2 (12.5 mm)
YGHC29C29
250 kcmil (0.575) 250 kcmil (0.575) 120 mm2 (14.4 mm) 120 mm2 (14.4 mm)
300 kcmil (0.630) #6 SOL. (0.162)
150 mm2 (16 mm) 10 mm2 (4.12 mm)
{300 kcmil}
{59500}
YGHC34C26
500 kcmil (0.813) 2/0 STR. (0.419)
240 mm2 (20.35 mm) 70 mm2 (10.9 mm)
{500 kcmil}
{98500}
300 kcmil (0.630) 3/0 STR. (0.470) 150 mm2 (16 mm) 95 mm2 (12.5 mm)
YGHC34C29
500 kcmil (0.813) 250 kcmil (0.575) 240 mm2 (20.35 mm) 120 mm2 (14.4 mm)
300 kcmil (0.630) 300 kcmil (0.630) 150 mm2 (16 mm) 150 mm2 (16 mm)
YGHC34C34
500 kcmil (0.813) 500 kcmil (0.813) 240 mm2 (20.35 mm) 240 mm2 (20.35 mm)

A
1.16
[30]

B
0.75
[19]

1.41
[36]

DIE
INDEX
NO.

INSTALLATION DATA
Y750/Y35

Y39
Y45
Y46
HYPRESS HYPRESS HYPRESS

NO. OF
CRIMPS

U-C

U-C

U-C

0.75
[19]

U-O

U-O

U-O

1.54
[39]

0.75
[19]

U-O

U-O

U-O

1.97
[50]

0.75
[19]

997

U997

U997

U997

2.06
[52]

0.88
[22]

997

U997

U997

U997

2.42
[62]

0.88
[22]

1011

U1011

S1011

P1011

2.67
[66]
2.91
[74]

0.88
[22]
1.1
[28]

1011

U1011

S1011

P1011

1011

U1011

S1011

P1011

Dimensions in brackets { } represent lightning


protection conductors.

NOTES:
Where a "U" or "PU" die is recommended with
the Y45 HYPRESS, PT6515 adapter must be
used.
Where a "U" or "PU" die is recommended with
the Y46 HYPRESS, a PUADP-1 adapter must
be used.
3. Listed under UL486A for copper wire connectors
. Dimensions in brackets [ ] are in millimeters.

134

5. In referencing connectors without PENETROX


oxide inhibitor add suffix "NP" to the end of the
Catalog Number.
These connectors can only be installed using
the Y750, Y45 or Y46 HYPRESS with the
recommended dies.
These connectors cannot be installed with the
Y35 and Y39 HYPRESS.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YGC
COPPER CRIMPIT
UL 467 Listed for direct burial in earth or
concrete. Prefilled with PENETROX E2
oxide inhibitor.

CATALOG
NUMBER
YGC8C8
YGC6C8
YGC6C6

COPPER
CONDUCTOR
RUN
TAP
#8 SOL.
#8 STR.
#6 SOL.
#6 STR.
#6 SOL.
#6 STR.

#8 SOL.
#8 STR.
#8 SOL.
#8 STR.
#6 SOL.
#6 STR.

HEIGHT

LENGTH

INDEX

OUR840

MD6/MD7

CRIMPS

.46

.52

162

W162

W162

.73

.62

BG

XBG

WBG

.76

.62

BG

XBG

WBG

For CUSTOMER SERVICE call 1-800-346-4175

135

BURNDY
Telecommunications Products
TYPE YSHG
HIGH STRENGTH
COPPER IRREVERSIBLE
COMPRESSION
Double H-Tap Connector
Type YSHG Double H-Tap grounding series is
comprised of five connectors designed to
accommodate wire range sizes #14 through
500 kcmil, including ground rod sizes: 3/4",
1", and rebar sizes: #6, #8 and #9. Prefilled
with PENETROX E2 and strip sealed.

Features and Benefits


UL467 Listed.
Suitable for direct burial in earth
or concrete.
Material is high conductivity
copper extrusion.
Minimizes resistance, eliminates
corrosion due to dissimilar metals.
Grooves are prefilled with PENETROX E2
oxide inhibitor and individually sealed.
Inhibits moisture and contaminants
ensuring electrical integrity.

Fig. 2

Fig. 1

CATALOG
NUMBER
YSHG4429
* YSHG3939
* YSHG3931
YSHG3434
YSHG3429

FIG.
NO.
3
1
2

1
2

CONDUCTOR SIZES
MAIN
TAP 1
#9 & #8 REBAR, 1 [25] GROUND
ROD
1 [25] Cu CLAD GROUND ROD
500 kcmil COPPER
#6 REBAR, 1 [25] Cu CLAD
GROUND ROD, 3/4 GROUND ROD
500 - 350 kcmil COPPER
#6 REBAR, 3/4 [19] GROUND ROD
400 - 250 kcmil COPPER
#6 REBAR, 3/4 [19] GROUND ROD
400 - 4/0 kcmil COPPER

TAP 2

Fig. 3

TAP 3

TOOLING
INDEX
(*NUMBER OF CRIMPS) EMBOSS- W
Y750
*
Y46
*
MENT
.06

250 - 2

PYFR

K-R

500 - 350

PYFR

K-R

PYFR

K-R

P1104
U1104
P1104
U1104

2
4
2
4

4/0 - 1/0

1-6

2 - 14

400 - 4/0
3/0 - 1/0

1-4

8 - 14

U1104

U1104

1104
1104

T
.04

L
.06

3.22
[82]
2.97
[75]

1.70
[43]
1.50
[38]

2.44
[62]
2.94
[75]

2.97
[75]

1.50
[38]

2.34
[59]

2.43
[62]
2.23
[57]

1.15
[29]
1.31
[33]

2.44
[62]
2.44
[62]

* NOTE: Not for use on 1 steel ground rod.


Use PUADP-1 adapter.

136

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YGL-C
HYGRID CROSS CONNECTOR
An irreversible compression ground grid
cross connector which allows adjustment of
the compression elements prior to installation. Only six connectors and four dies are
required to install all combinations from #6
solid through 500 kcmil. UL467 Listed.
Acceptable for direct burial in earth and concrete. Prefilled with PENETROX compound
and strip sealed.

CATALOG
NUMBER
YGL2C2
YGL29C2
YGL29C29
YGL34C2
YGL34C29
YGL34C34

CATALOG
NUMBER
YGL2C2
YGL29C2
YGL29C29
YGL34C2
YGL34C29
YGL34C34

B-B

MEETS ALL

IEEE
467

C
1.09

.75

.75

1.66
2.09

1.10

1.10

2.28

837 REQUIREMENTS

96

C-C

1.09

.313

1.66
1.09
1.66
2.28

.500
.313
.500
.750

CABLE TO CABLE
ELEMENT A
ELEMENT B
#6 SOL. (.162) #2 STR. (.292)
{59500} {59500}
#6 SOL. (.162) #2 STR. (.292)
#1 STR. (.332) 250 kcmil (.575)
{59500} {59500}
{98500} {131500}
#2 STR. (.292) 250 kcmil (.575)
#2 STR. (.292) 250 kcmil (.575)
{65500} {131500}
{65500} {131500}
#6 SOL. (.162) #2 STR. (.292)
250 kcmil (.575) 500 kcmil (.813)
#2 STR. (.292) 250 kcmil (.575)
250 kcmil (.575) 500 kcmil (.813)

R
.31
.50
.31
.50
.75

2.50

UL96 Listed for Lightning Protection.

CABLE TO GROUND ROD


ELEMENT A
ELEMENT B

TO REBAR
ELEMENT A

#6 SOL. (.162) #2 STR. (.292)

3/8" 1/2"

#2 STR. (.292) 250 kcmil (.575)

#3 4 Rebar

#6 SOL. (.162) #2 STR. (.292)


#2 STR. (.292) 250 kcmil (.575)
250 kcmil (.575) 500 kcmil (.813)

5/8" 3/4"
#5 6 Rebar

1/2" 5/8" Rod

5/8" 3/4" Rod

Dimensions in brackets { } represent lightning


protection conductors.

CATALOG
NUMBER

INSTALLATION TOOLS, DIE SET CAT. NO. (NUMBER OF CRIMPS)


Y750/Y35/Y39 HYPRESS
PAT750-18V
Y45 HYPRESS
Y46 HYPRESS
ELEMENT A ELEMENT B ELEMENT A ELEMENT B ELEMENT A ELEMENT B ELEMENT A ELEMENT B

YGL2C2
YGL29C2
YGL29C29

U-0 (1)
U997 (1)
U997 (1)

U-0 (1)
U-0 (1)
U997 (1)

U-0 (1)
U997P (1)
U997P (1)

U-0 (1)
U-0 (1)
U997P (1)

YGL34C2*

PU998 (1)

U-0 (1)

PU998 (1)

U-0 (1)

YGL34C29*

PU998 (1)

U997 (1)

PU998 (1)

U997P (1)

YGL34C34*

U1011 (3)

U1011 (3)

U1011 (3)

U1011 (3)

1. Where a "U" or "PU" die is recommended with Y45


HYPRESS, a PT6515 adapter must be used.
2. Where a "U" or "PU" die is recommended with the Y46
HYPRESS, a PUADP-1 adapter must be used.
Polarized die for the PAT750-18V.

NOTES:
Before crimping, both connector elements can
be turned on rod diameter "D" to any desired
position.
Clean rust and/or protective coatings from rebar
prior to installation.

U-0 (1)
U997 (1)
U997 (1)
S998 or
PU998 (1)
S998 or
PU998 (1)
S1011 (3)

U-0 (1)
U-0 (1)
U997 (1)
U-0 (1)
U997 (1)
S1011 (3)

U-0 (1)
U997 (1)
U997 (1)
P998 or
PU998 (1)
PU998 or
PU998 (1)
P1011 (3)

U-0 (1)
U-0 (1)
U997 (1)
U-0 (1)
U997 (1)
P1011 (3)

* These connectors can only be installed using the Y750,


Y45, or Y46 HYPRESS with the recommended dies.
These connectors CANNOT be installed with the Y35 and
Y39 HYPRESS.

When attaching connector to ground rod, ground


rod must be embossed with appropriate UPRECRIMP die. For connections that must meet
IEEE 837 requirements UPRECRIMP - type
PRE crimp dies must be used for maximum
clamping retention.

For CUSTOMER SERVICE call 1-800-346-4175

GROUND ROD
DIA.
1/2
5/8
3/4

UPRECRIMP DIES
UPRECRIMP 12
UPRECRIMP 58
UPRECRIMP 34

U2CABT

137

BURNDY
Telecommunications Products
TYPE YGHR-C
HYTAIL
High Strength
Irreversible
Compression Ground Rod Tap
Connectors
Type YGHR-C irreversible compression
grounding connector is engineered specifically for the Telecommunications Industry for
(1, 2 or 3) #2 solid, tinned or bare conductor
taps. UL467 Listed. Acceptable for direct burial
in earth or concrete. BURNDY has designed
this connector to meet the stringent requirements of OSHA, the National Electric Code
(NEC), UL, and the Telecommunications
Industry. Performance and long life are this
connectors basic design guidelines.

Features and Benefits


Tap side 1, 2 or 3 conductors.
One connector style can be used for
many applications.
Material is high conductivity wrought
copper extrusion, identical material to
the conductor.
High-conductivity copper minimizes
resistance and voltage drop. Eliminates
the possibility of corrosion due to
dissimilar metals.
System engineered tooling.
Each tooling recommendation has
been designed to provide a reliable,
dependable connection.

YGHR58C2W-3

GROUND ROD
DIAMETER
5/8

Contact BURNDY for other ground rod diameters.


* PU998 and U1011 die sets require PUADP-1 adapter for
use in the Y46 HYPRESS.
Tap positions may be left void when fewer than (3) conductors are used.
+ To order electro-tin plated connector for use on galvanized
steel ground rod add suffix -TN to the catalog number.
NOTE: The ground rod hole diameter is larger for galvanized
steel ground rod in the tin plated connector.

138

TAP

RUN

TAP

CATALOG
NUMBER+

The die index number is embossed on


connector after completion of crimp.
Facilitates speedy inspection of installed
connectors to ensure consistently
reliable and dependable connections.
Prefilled with PENETROX and individually
sealed in clear polyethylene sheet.
Ensures the electrical integrity of the
finished connection by inhibiting moisture
and contaminates from entering the
contact area. Maintains long-term
high-conductivity.
UL 467 Listed. Acceptable for direct burial.
May be used in direct burial or concrete
embedded grounding applications.
Provides quality assurance to recognized
industry NEC standards from an
independent party.

TAP CONDUCTOR
#2 Sol. Copper 1, 2, or 3
may be connected

INSTALLATION TOOLING
Y35/Y750**
Y46*
DIE
NO. OF
DIE
NO.
CRIMPS
NO.
PU998

(1)

U1011

(2)

PU998
U1011
P998
P1011

AND

RUN

NO. OF
CRIMPS

DIE
INDEX

(1)
(2)
(1)
(2)

998 or
1011

Ground rod must be precrimped with die U2CABT (Index


No. 348) when PU998 die set is used in the Y35, Y750 or
Y46
HYPRESS tools. For even greater mechanical resistance
use UPRECRIMP 58 dies.
** The Y750 utilizes PU dies and the U1011 die. The Y35 only
uses PU998 die set.
NOTE: A 12" bend radius is recommended for the conductor.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YGHA
HYLUG
Heavy Duty Irreversible
Compression Terminals
Heavy duty HYLUG irreversible compression terminals are designed not only to carry
short circuit load, but to also withstand high
mechanical stress. Each conductor element
has an inspection probe hole to insure proper
cable insertion. UL467 Listed. Acceptable for
direct burial in earth or concrete. UL486A
Listed. Prefilled with PENETROX compound and strip sealed.

CATALOG
NUMBER
YGHA2C-2N
YGHA25-2N
YGHA26-2N
YGHA27-2N
YGHA28-2N
YGHA29-2N
YGHA31-2N
YGHA34-2N

MEETS ALL

IEEE

837 REQUIREMENTS

COPPER CONDUCTOR SIZE

INSTALLATION TOOLS, DIE SET CAT. NO.,


AND (NUMBER OF CRIMPS)
HYPRESS Y35/Y39/Y45 /Y46 /Y750

2 str.
1/0 str.
2/0 str.
3/0 str.
4/0 str.
250 kcmil
350 kcmil
500 kcmil

U1CRT (1)
U27RT (1)
U28RT (1)
U29RT (1)
U30RT (2)
U31RT (2)
U34RT (2)
U36RT (3)

.75
.83
.83
1.18
1.18
1.18
1.18
1.48

.97
.91
.97
1.08
1.22
1.28
1.62
1.72

4.21
4.60
4.38
4.94
4.94
4.94
5.00
5.42

.26
.19
.26
.29
.30
.34
.43
.40

Where a U or PU die is recommended with the Y45


HYPRESS, a PT6515 adapter must be used.
Where a U or PU die is recommended with the Y46
HYPRESS, a PUADP-1 adapter must be used.

TYPE YGHS
HYLINK
Heavy Duty Irreversible
Compression Terminals
Heavy duty HYLINK ground splices are
designed not only to carry short circuit load,
but to also withstand high mechanical stress.
Each conductor element has an inspection
probe hole and a center stop to ensure
proper cable insertion. UL467 Listed.
Acceptable for direct burial in earth or
concrete. UL486A Listed. Prefilled with
PENETROX compound and strip sealed.

CATALOG
NUMBER
YGHS2C
YGHS25
YGHS26
YGHS27
YGHS28
YGHS29
YGHS31
YGHS34

KNURLED
RINGS
INSPECTION PROBE HOLES
FOR CABLE STOP

MEETS ALL

IEEE

837 REQUIREMENTS

COPPER CONDUCTOR SIZE

INSTALLATION TOOLS, DIE SET CAT. NO.,


AND (NUMBER OF CRIMPS)
HYPRESS Y35/Y39/Y45 /Y46 /Y750

2 str.
1/0 str.
2/0 str.
3/0 str.
4/0 str.
250 kcmil
350 kcmil
500 kcmil

U1CRT (1)
U27RT (1)
U28RT (1)
U29RT (1)
U30RT (2)
U31RT (2)
U34RT (2)
U36RT (3)

.75
.83
.83
1.18
1.18
1.18
1.18
1.48

1.73
1.89
1.89
2.59
2.59
2.59
2.59
3.19

Where a U or PU die is recommended with the Y45


HYPRESS, a PT6515 adapter must be used.
Where a U or PU die is recommended with the Y46
HYPRESS, a PUADP-1 adapter must be used.

For CUSTOMER SERVICE call 1-800-346-4175

139

BURNDY
Telecommunications Products
TYPE YGA
HYLUG
Grounding Irreversible
Compression Terminals
Irreversible compression HYLUG ground
terminal specifically designed for grounding
applications. Each connector has an inspection probe hole to ensure proper cable insertion. UL467 Listed. Acceptable for direct
burial in earth or concrete. UL486A Listed.
Prefilled with PENETROX compound and
strip sealed.

Fig. 2

Fig. 1

CATALOG
NUMBER

FIG.
NO.

COPPER
CONDUCTOR
SIZE

INSTALLATION TOOLS, DIE SET CAT. NO., AND


(NUMBER OF CRIMPS)
MECHANICAL
HYDRAULIC
Y35, Y39, Y45,
Y2MR
MD7-34R
OUR840
Y46, Y750
DIE # (# OF
DIE # (# OF
DIE # (# OF
DIE # (# OF STUD
CRIMPS)
CRIMPS)
CRIMPS)
CRIMPS)
SIZE

YGA8C-TC10

8 sol./8 str.

Red (4)

YGA8C-TC14

8 sol./8 str.

Red (4)

YGA8C-TC516

8 sol./8 str.

Red (4)

YGA8C-2N

8 sol./8 str.

Red (4)

YGA6C-TC10

6 sol./6 str.

Blue (4)

YGA6C-TC14

6 sol./6 str.

Blue (4)

YGA6C-TC516

6 sol./6 str.

Blue (4)

YGA6C-2TC38E2G1

6 sol./6 str.

Blue (4)

YGA6C-2N

6 sol./6 str.

Blue (4)

YGA2C-2TC38

2 sol./2 str.

Brown (4)

YGA2C-2TC38E2G1

2 sol./2 str.

Brown (4)

YGA2C-2N

2 str.

Brown (4)

YGA25-2N

1/0 str.

YGA26-2N

2/0 str.

YGA28-2N

4/0 str.

YGA29-2N
YGA34-2N

1
1

250 kcmil
500 kcmil

Where a U or PU die is recommended with the Y45


HYPRESS, a PT6515 adapter must be used.

140

W8CVT (2)
X8CRT (2)
W8CVT (2)
X8CRT (2)
W8CVT (2)
X8CRT (2)
W8CVT (2)
X8CRT (2)
W5CVT (2)
X5CRT (2)
W5CVT (2)
X5CRT (2)
W5CVT (2)
X5CRT (2)
W5CVT (2)
X5CRT (2)
W5CVT (2)
X5CRT (2)
W2CVT (2)
X2CRT (2)
W2CVT (2)
X2CRT (2)
W2CVT (2)
X2CRT (2)
W25VT (4)
X25RT (4)
W26VT (4)
X26RT (4)
W28VT (4)
X28RT (4)
W29VT (4)
W34VT (4)

U8CRT (2)

#10

.81

.41

1.57

.08

U8CRT (2)

1/4

.81

.44

1.69

.08

U8CRT (2)

5/16

.81

.51

1.75

.06

U8CRT (2)

1/2

.81

.71

4.09

.05

1.75

U5CRT (2)

#10

1.12

.42

1.89

.09

U5CRT (2)

1/4

1.12

.45

2.02

.08

U5CRT (2)

5/16

1.12

.51

2.08

.07

U5CRT (2)

3/8

1.12

.58

3.42

.06

.75

U5CRT (2)

1/2

1.12

.83

4.40

.12

1.75

U2CRT (2)

3/8

1.25

.60

3.48

.12

1.00

U2CRT (2)

3/8

1.25

.60

3.66

.12

.75

U2CRT (2)

1/2

1.22

.81

4.71

.12

1.75

U25RT (2)

1/2

1.35

.81

4.91

.12

1.75

U26RT (2)

1/2

1.45

.81

4.89

.12

1.75

U28RT (2)

1/2

1.57 1.00 5.06

.14

1.75

U29RT (2)
U34RT (4)

1/2
1/2

1.57 1.09 5.16


2.20 1.52 5.94

.16
.23

1.75
1.75

Where a U or PU die is recommended with the Y46


HYPRESS, a PUADP-1 adapter must be used.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YGS
HYLINK
Grounding Irreversible
Compression Splices
Irreversible compression HYLINK ground
splices specifically designed for grounding
applications. Each conductor element has an
inspection probe hole and a center stop to
ensure proper cable insertion. UL467 Listed.
Acceptable for direct burial in earth or
concrete. UL486A Listed. Prefilled with
PENETROX compound and strip sealed.

CATALOG
NUMBER

COPPER
CONDUCTOR
SIZE

Y2MR
DIE # (# OF
CRIMPS)

YGS2C

2 str.

Brown (4)

YGS8C
YGS6C

#8 sol./str.
#6 sol./str.

YGS25

1/0 str.

YGS26

2/0 str.

YGS28

4/0 str.

YGS29
YGS34

250 kcmil
500 kcmil

INSTALLATION TOOLS, DIE SET CAT. NO., AND


(NUMBER OF CRIMPS)
MECHANICAL
HYDRAULIC
MD7-34R
OUR840
Y35, Y39, Y45,
DIE # (# OF
DIE # (# OF
Y46, Y750
CRIMPS)
CRIMPS)
DIE # (# OF CRIMPS)
W2CVT (2)
X2CRT (2)
X8CRT, W8CRT, W8CVT
X5CRT, W5CRT, W5CVT
W25VT (4)
X25RT (4)
W26VT (4)
X26RT (4)
W28VT (4)
X28RT (4)
W29VT (4)
W34VT (4)

U2CRT (2)

1.22

2.67

U8CRT (2)
U6CRT (2)

.78
1.09

1.75
2.38

U25RT (2)

1.35

2.97

U26RT (2)

1.45

3.13

U28RT (2)

1.57

3.37

U29RT (2)
U34RT (4)

1.57
2.20

3.37
4.63

Where a U or PU die is recommended with the Y45


HYPRESS, a PT6515 adapter must be used.

Where a U or PU die is recommended with the Y46


HYPRESS, a PUADP-1 adapter must be used.

Use "X" with OUR840, "W" with MD6/MD7. Up to 4/0


would be any MD- style tool (example: MD6-8).

For CUSTOMER SERVICE call 1-800-346-4175

141

BURNDY
Telecommunications Products
TYPE YGIB

MEETS ALL

GROUNDLINK CONNECTOR

837 REQUIREMENTS

IEEE

An irreversible compression ground connection which allows attachment to a structural


steel standard (angled) or wide flange
(parallel) beam. Installed with a required
5-piece die set, Catalog PIBEAMKIT or
UIBEAMKIT.
Die
index
1105.
GROUNDLINK connectors are made of
high-conductivity wrought copper and come
pre-filled with PENETROX E compound
and strip sealed. Order terminal mounting
hardware separately.

1.84 IN. Minimum flange depth.


3.06 IN. Minimum flange width.

Connector shipped with thread protection studs only. Order


TMHG kits separately.

Fig. 1

Y46 SERIES
USE PIBEAMKIT

Y750 SERIES
USE UIBEAMKIT

Fig. 2
T REF MAXIMUM
TERMINAL PAD
THICKNESS

2 HOLE NEMA
SPACING

STANDARD BEAMS
(FLANGE ANGLED) USE YGIBS)

TERMINAL
MOUNTING HARDWARE
CATALOG NUMBER
T
TMHG-42

.42

TMHG-92

.92

NOTE: Use TMHG-D92 to double stack lugs.


WIDE FLANGE BEAMS
(FLANGE PARALLEL) USE YGIBW

NOTES:
1. Terminal conector to be ordered separately. When I-beam
connector is used with type "YGHA" terminal, the connection meets IEEE 837-1989 requirements. YGA-2N, YA-2N
and other BURNDY 2-hole NEMA copper terminals are
suitable.
2. Order "TMHG" Terminal Mounting Hardware Kit separately. Kit consists of 2 studs, 2 flat washers, 2 lockwashers
and 2 hex nuts.

Dimensions shown reflect the minimum dimensions


required on a beam to properly install the I-beam
connector.

5. To correctly determine the appropriate YGIB connector to


use based on flange thickness, order either
YGIBGAUGE1 or YGIBKIT1 (KIT1 contains wiremike).

3. Using the 1/4 hex key wrench, screw the stud into the
connector until stud bottoms out in connector. Install a
"YGHA" terminal, flat washer, lockwasher and hex nut
onto stud. Tighten and torque to 480 pound-inches.

142

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE YGIB
(Continued)
GROUNDLINK CONNECTOR
COPPER
CONDUCTOR
RANGE

CATALOG NUMBER

FIG.
NO.

YGIBS28-338-2N

3.00

YGIBW28-338-2M

3.00

YGIBS34-338-2N
YGIBW34-338-2N

1
2

6.00

YGIBS28-400-2N

3.00

YGIBW28-400-2N

3.00

YGIBS34-400-2N
YGIBW34-400-2N

1
2

6.00

YGIBS28-462-2N

3.00

YGIBW28-462-2N

3.00

YGIBS34-462-2N
YGIBW34-462-2N

1
2

6.00

YGIBS28-550-2N

3.00

YGIBW28-550-2N

3.00

YGIBS34-550-2N
YGIBW34-550-2N

1
2

6.00

YGIBS28-613-2N

3.00

YGIBW28-613-2N

3.00

YGIBS34-613-2N
YGIBW34-613-2N

1
2

6.00

YGIBS28-675-2N

3.00

YGIBW28-675-2N

3.00

YGIBS34-675-2N
YGIBW34-675-2N

1
2

6.00

2 - 4/0 AWG

250 - 500 kcmil

.250
to
.338

2 - 4/0 AWG

250 - 500 kcmil

2 - 4/0 AWG
250 - 500 kcmil

2 - 4/0 AWG

250 - 500 kcmil

2 - 4/0 AWG

250 - 500 kcmil

For CUSTOMER SERVICE call 1-800-346-4175

.338
to
.400

.400
to
.462
1/2 - 13

2 - 4/0 AWG

250 - 500 kcmil

iBEAM
FLANGE
THICKNESS

4.62
to
.550

.550
to
.613

.613
to
.675

SUGGESTED TERMINALS
COPPER CONDUCTOR
TERMINAL
#2 STR.
1/0 STR.
2/0 STR.
4/0 STR.
250 kcmil
500 kcmil
#2 STR.
1/0 STR.
2/0 STR.
4/0 STR.
250 kcmil
500 kcmil
#2 STR.
1/0 STR.
2/0 STR.
4/0 STR.
250 kcmil
500 kcmil
#2 STR.
1/0 STR.
2/0 STR.
4/0 STR.
250 kcmil
500 kcmil
#2 STR
1/0 STR.
2/0 STR.
4/0 STR.
250 kcmil
500 kcmil
#2 STR.
1/0 STR.
2/0 STR.
4/0 STR.
250 kcmil
500 kcmil

YGHA2C-2N
YGHA25-2N
YGHA26-2N
YGHA28-2N
YGHA29-2N
YGHA34-2N
YGHA2C-2N
YGHA25-2N
YGHA26-2N
YGHA28-2N
YGHA29-2N
YGHA34-2N
YGHA2C-2N
YGHA25-2N
YGHA26-2N
YGHA28-2N
YGHA29-2N
YGHA34-2N
YGHA2C-2N
YGHA25-2N
YGHA26-2N
YGHA28-2N
YGHA29-2N
YGHA34-2N
YGHA2C-2N
YGHA25-2N
YGHA26-2N
YGHA28-2N
YGHA29-2N
YGHA34-2N
YGHA2C-2N
YGHA25-2N
YGHA26-2N
YGHA28-2N
YGHA29-2N
YGHA34-2N

T REF.
.26
.19
.26
.30
.34
.40
.26
.19
.26
.30
.34
.40
.26
.19
.26
.30
.34
.40
.26
.19
.26
.30
.34
.40
.26
.19
.26
.30
.34
.40
.26
.19
.26
.30
.34
.40

143

BURNDY
Telecommunications Products
TYPE YG-B
BUS BAR CONNECTOR
BURNDYs YG-B type Compression Bus Bar
Connector is ideally suited for cellular tower
applicatons and is easier to use than exothermic connections. This high conductivity
wrought copper connector allows attachment
of the ground conductor to the ground bus
with just one crimp using the BURNDY Y750
HYPRESS Hydraulic Compression tool
and the U1105 die set. This exclusive patent
pending design allows the user to attach #2
AWG sol./str. and/or #6 sol./str. copper conductor to 1/4 thick copper bus bar. This connection is suitable using (1) or (2) conductors
for power, grounding and bonding applictions.
UL Listed to both UL486 and UL467 (suitable
for direct burial) ensures that this connector
will meet the rigors of either application.
Prefilled with PENETROX E compound and
strip sealed.

Fig. 1

Fig. 3

FIG NO.

GROUND BAR
THICKNESS

YG14B2TC2C6C

1/4"

YG14B2TC2C2C*

1/4"

YG14BTC26

1/4"

YG14BTC28

1/4

CATALOG NUMBER

Fig. 2

BUS BAR
TAP CONDUCTORS
#2 SOL/and/or STR COPPER
#6 SOL/and/or STR COPPER
#2
#2
#1 FLEX CABLE
through
2/0 FLEX CABLE
4/0 AWG STR to 1/0
AWG STR COPPER

TOOLING

INSTALLATION
DIE NO.

NO. OF CRIMPS

Y750

U1105

Y750

U1105

Y750

U1105

Y750

U1105

NOTE: Suitable for use with either (1) or (2) conductors


(excluding YG14BTC26 and YG14BTC28).
* For continuous uncut conductor applications.

144

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE HFB-P1
BAR CLAMP ASSEMBLY
COMPONENTS
FOR COPPER BAR
To build your own high strength clamp assembly for multiple flat bar using type HFB-P1 bar
clamps & clamping hardware, the following
tables have been provided. The clamp
assembly eliminates the need for drilling the
flat bar and is used in indoor and outdoor
applications.

ONE CLAMP HALF


BUS BAR
J
RUN
TAP
BOLT
A
AA
DIA.

BAR CLAMP
CATALOG
NUMBER
HFB33P1
HFB44P1
HFB63P1
HFB66P1
HFB88P1

3.00
4.00
6.00
6.00
8.00

COPPER
BUS BAR
WIDTH (INCHES)
RUN-A
TAP-AA
3
4
6
6
8

Position for assembly


(2) Reqd
for assembly

3
4
3
6
8

3.00
4.00
3.00
6.00
8.00

3/8
1/2
1/2
5/8
3/4

4.38
5.75
7.75
8.12
10.50

4.38
5.75
4.75
8.12
10.50

Bar Clamp
Assembly

BAR CLAMP ASSEMBLY COMPONENTS


SILICON BRONZE CLAMPING HARDWARE
BAR CLAMP
BOLTS**
NUTS
SPLIT LOCKWASHERS
QTY.
CAT. NO.
QTY.
CAT. NO.
QTY.
CAT. NO.
QTY.
CAT. NO.
2
2
2
2
2

HFB33P1
HFB44P1
HFB63P1
HFB66P1
HFB88P1

4
4
4
4
4

38 X (*) HEB
50 X (*) HEB
50 X (*) HEB
62 X (*) HEB
75 X (*) HEB

4
4
4
4
4

38CHEN
50CHEN
50CHEN
62CHEN
75CHEN

4
4
4
4
4

38SW
50SW
50SW
62SW
75SW

WHEN
Z=2.25*

WHEN
Z=2.50*

WHEN
Z=2.75*

WHEN
Z=3.00*

4.00
4.50
4.50
4.50
5.00

4.50
4.50
4.50
5.00
5.00

4.50
5.00
5.00
5.00
5.50

5.00
5.00
5.00
6.00
5.50

Ordered separately from BURNDY.


* Z = Space between the bar clamp contact surfaces.
* * See table below when ordering assembly clamping bolts to
specify correct bolt length in Cat. #.

CLAMP
NUMBER

J
BOLT DIA.

WHEN
Z=1.25*

WHEN
Z=1.50*

HFB33P1
HFB44P1
HFB63P1
HFB66P1
HFB88P1

3/8(-16)
1/2(-13)
1/2(-13)
5/8(-11)
3/4(-10)

3.00
3.25
3.25
3.50
3.75

3.25
3.50
3.50
4.00
4.00

For CUSTOMER SERVICE call 1-800-346-4175

BOLT LENGTH**
WHEN
WHEN
Z=1.75*
Z=2.00*
3.50
3.75
3.75
4.00
4.50

4.00
4.00
4.00
4.50
4.50

145

BURNDY
Telecommunications Products
TYPE HFBW
BAR CLAMP
FOR COPPER BAR
The clamp assembly eliminates the need for
drilling the flat bar and is used in indoor and
outdoor applications.
The open web design provides a uniform
clamping pressure while minimizing the
weight of the connector.

Fig. 1

CATALOG
NUMBER *
HFBW86T20CG1
HFBW66T16CG1
HFBW64T17CG1
HFBW63T10CG1
HFBW62T10CG1
HFBW44T17CG1
HFBW43T10CG1
HFBW42T10CG1
HFBW32T5CG1

CONDUCTOR
RUN
TAP
8.0
6.0
6.0
6.0
6.0
4.0
4.0
4.0
3.0

6.0
6.0
4.0
3.0
2.0
4.0
3.0
2.0
2.0

Fig. 2

FEATURES

BENEFITS

Web design cast copper body.


Fully threaded yellow galvanized bolts with
split-lockwashers and nuts included.
Flat bar accommodation molded into body.

Increased torsional resistance.


Reduced weight.
Simple installation.
Easy identification.

FIG.
NO.

STD.
MAX. Z
DIM.

TOTAL NO.
OF FLAT
BARS (STD.
1/4 THICK)

BOLT SIZE

2
2
2
1
1
2
2
1
1

5.00
4.00
4.25
2.50
2.50
4.25
2.50
2.50
1.25

20
16
17
10
10
17
10
10
5

5/8-11
1/2-13
1/2-13
3/8-16
3/8-16
1/2-13
3/8-16
3/8-16
3/8-16

8.13
7.75
5.75
4.70
3.44
5.68
4.42
3.54
3.54

10.13
7.75
7.75
7.63
7.44
5.68
5.42
5.55
4.55

DIMENSIONS

* Catalog number based on standard maximum Z


dimension. Refer to your representative for nonstandard Z dimensions.
Add TN suffix for tin plating (example: HFBW86T20CG1TN).
All dimensions in inches.

146

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE HFB-N
BAR CLAMP TAP PAD
ADAPTER
FOR COPPER BAR
High conductivity copper, tap pad adapter
provides a NEMA drilled contact pad when
assembled to the HFB-P1 clamps. Tap connections can be made from copper bus bar(s)
without drilling by bolting standard mechanical or compression terminal pads directly to
the pre-drilled tap pad adapter.

Fig. 1
Fig. 2
USE WITH H

CATALOG
NUMBER

FIG.
NO.

A-C

E&F

CLAMP CAT. NO.

HFB33-4N
HFB44-4N
HFB66-6N

1
1
2

3.00
4.00
6.00

1.75
1.75
1.75

7.00
9.12
11.31

.62
1.12
1.12

HFB33P1
HFB44P1
HFB66P1

H Clamp (two required per assembly) and hardware


(as shown) not included with bar clamp tap pad, order
separately.

For CUSTOMER SERVICE call 1-800-346-4175

147

BURNDY
Telecommunications Products
MECHANICAL
GROUNDING
CONNECTORS
More than 60 years of technological innovation has made BURNDY mechanical
grounding connectors one of the most widely
used, highly respected lines in the industry.
There is virtually no grounding application
problem that this diversified line cannot help
solve.

All BURNDY mechanical grounding connectors have been designed for easy installation
and for outstanding durability. Only the finest
high copper alloys are used in their manufacture, ensuring top performance under the
most extreme environmental conditions.

TYPES KC, K2C


SERVIT POST
For Copper Cable to Flat
SERVIT POST used to ground one or two
cables to steel structures, fence posts, transformers. Also used to tap one or two cables
from bus bar. One-wrench installation.

KC

CATALOG NUMBER
TYPE KC
TYPE K2C
KC15
KC15B1
KC17
KC17B1
KC20
KC20B1
KC22
KC22B1
KC23
KC23B1
KC25
KC25B1
KC26
KC26B1
KC28
KC28B1
KC31
KC31B1
KC34
KC34B1

K2C15
K2C15B1
K2C17
K2C17B1
K2C20
K2C20B1
K2C22
K2C22B1
K2C23
K2C23B1
K2C25
K2C25B1
K2C26
K2C26B1
K2C28
K2C28B1
K2C31
K2C31B1
K2C34
K2C34B1

CONDUCTOR
STRANDED
SOLID

STUD
DIAMETER

12 - 9

12 - 8

1/4 - 20

10 - 7

10 - 6

1/4 - 20

10 - 5

10 - 4

5/16 - 18

10 - 3

10 - 2

3/8 - 16

8-2

10 - 1

3/8 - 16

2 - 1/0

2 - 2/0

1/2 - 13

2 - 2/0

2 - 3/0

1/2 - 13

1 - 4/0

1 - 4/0

5/8 - 11

1 - 350

5/8 - 11

3/0 - 500

3/4 - 10

B
3/8
7/8
3/8
7/8
13/32
27/32
15/32
31/32
15/32
31/32
9/16
1-1/16
17/32
1-1/16
3/4
1-1/4
3/4
1-1/4
1
1-1/2

K2C

CFx

CFy

1/2

3/8

5/8

7/16

11/16

1/2

3/4

5/8

13/16

5/8

15/16

3/4

7/8

1-1/2

1-3/16

1-11/16

1-3/8

1-5/8

D
1/2
1
1/2
1
5/8
1
5/8
1-1/8
5/8
1-1/8
3/4
1-1/4
3/4
1-1/4
1
1-1/2
1
1-1/2
1-1/4
1-3/4

HH

5/8

7/8

7/8

7/8

1-1/8

1-1/4

1-3/8

1-1/8

1-5/8

1-3/8

1-7/8

1-3/4

2-1/4

2-1/4

2-7/8

2-3/8

3-1/4

Add NSP suffix to have connector supplied w/split lockwasher


and nut.

148

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE KS-DB
SERVIT
For Copper
UL467 Listed for direct burial applications in
earth or concrete. Compact, high-strength,
high copper alloy SERVIT split-bolt has
free-running threads and easy to grip wrench
flats. Highly resistant to cracking and
corrosion.

Catalog
Number

Cross Flats

KS15-DB
KS17-DB
KS20-DB
KS22-DB
KS23-DB
KS25-DB

.50
.63
.69
.75
.82
.94

.85
1.14
1.20
1.50
1.54
1.77

.38
.45
.51
.60
.62
.73

KS26-DB

1.05

1.94

.82

KS27-DB

1.36

1.86

1.17

KS29-DB

1.36

2.07

1.17

KS31-DB

1.70

2.51

1.41

KS34-DB

1.82

2.79

1.48

For CUSTOMER SERVICE call 1-800-346-4175

Copper Conductor Range


(Sol. - Str.)

Rebar w/ (1)
No. 8 Sol. Cu

Recommended
Torque In. Lb.

12 AWG - 8 AWG
8 AWG - 6 AWG
8 AWG - 4 AWG
6 AWG - 3 AWG
6 AWG - 2 AWG
4 AWG - 1/0
2 AWG - 2/0
6 AWG - 8 AWG Str./Sol.
1 AWG - 3/0
1 AWG - 250 kcmil
6 AWG - 8 AWG Str./Sol.
1/0 AWG - 350 kcmil
6 AWG - 8 AWG Str./Sol.
2/0 AWG - 500 kcmil
6 AWG - 8 AWG Str./Sol.

N/A
N/A
N/A
N/A
N/A
N/A
#3
(3/8)
N/A
#4
(1/2)
#5
(5/8)
#6
(3/4)

80
165
165
275
275
385
385
500
650
650
825

149

BURNDY
Telecommunications Products
TYPE KSU
UNIVERSAL SERVIT
For All Combinations of
Copper, Aluminum, ACSR,
AAAC, 5005, & Steel
Tin-plated, high strength copper alloy
SERVIT with spacer. Spacer separates
dissimilar conductors and provides long contact length that prevents high pressure point
contacts between run and tap conductors.

Use of PENETROX joint compound recommended with aluminum or ACSR.


486A
Copper Only

CONDUCTOR

RUN
CATALOG CROSS
NUMBER
FLAT L
KSU17
KSU20
KSU22
KSU23
KSU25
KSU26
KSU27
KSU29
KSU31
KSU34

150

.62
.69
.74
.81
.93
1.04
1.38
1.38
1.69
2.00

.92
1.05
1.25
1.48
1.77
1.93
2.34
2.50
2.88
3.12

COPPER &
ALUMINUM

.70 12 Sol. - 6 Sol.


.78 10 Sol. - 4 Sol.
.84 10 Sol. - 2 Sol.
.94
8 Str. - 2 Str.
1.06 2 Str. - 1/0 Str.
1.19 1/0 Str. - 2/0 Str.
1.58 1 Str. - 3/0 Str.
1.58
1 Str. - 250
1.91
4/0 Str. - 350
2.28
400 - 500

TAP
ACSR, AAAC,
5005

COPPER &
ALUMINUM

8 (6 - 1)
12 Sol. - 6 Sol.
6 (6 - 1)
10 Sol. - 4 Sol.
6 (6 - 1) - 4 (7 - 1)
10 Sol. - 2 Sol.
3 (6 - 1) - 2 (6 - 1)
8 Sol. - 2 Str.
3 (6 - 1) - 1 (6 - 1)
10 Str. - 1/0 Str.
1 (6 - 1) - 1/0 (6 - 1)
8 Str. - 2/0 Str.
1 (6 - 1) - 2/0 (6 - 1)
8 Sol. - 3/0 Str.
2/0 (6 - 1) - 4/0 (6 - 1)
8 Str. - 250
3/0 (6 - 1) - 4/0 (6 - 1)
4 Str. - 350
336 (30 - 7) - 477 (18 - 1)
2 Str. - 500

ACSR, AAAC,
5005
8 (6 - 1)
6 (6 - 1)
6 (6 - 1) - 4 (7 - 1)
6 (6 - 1) - 2 (6 - 1)
6 (6 - 1) - 1 (6 - 1)
6 (6 - 1) - 1/0 (6 - 1)
8 (6 - 1) - 2/0 (6 - 1)
6 (6 - 1) - 4/0 (6 - 1)
4 (6 - 1) - 4/0 (6 - 1)
2 (6 - 1) - 477 (18 - 1)

MAXIMUM
CONDUCTOR
STEEL
SOL. 3 STR. RECOMMENDED
NOM. BWG
TIGHTENING
BWG DIA.
TORQUE in.-lb.
8
6
4

8
6
4

5/32
7/32
1/4
5/16
3/8
7/16
1/2
1/2
5/8

165
275
275
385
385
500
650
650
825

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE GAR
FENCE POST GROUNDING
CONNECTOR
For Parallel or 90
Copper Cable
Connection
To Rod or Pipe with
the Same Connector
High copper alloy ground connector for joining a range of cable, parallel or at right angles
to rod or tube. Especially good for fence
posts. High copper alloy cast body with
DURIUM U-bolts, nuts and lockwashers,
permit entire connection to be buried in
ground or concrete without danger of
corrosion.
One-wrench installation.
UL467 Listed.
Acceptable for direct burial.

Catalog
Number
GAR114C
GAR1126
GAR1129
GAR644C
GAR6426
GAR6429
GAR6434
GAR144C
GAR1426
GAR1429
GAR1434
GAR154C
GAR1526
GAR1529
GAR1534
GAR164C
GAR1626
GAR1629
GAR1634
GAR174C
GAR1726
GAR1729
GAR1734
GAR184C
GAR1826
GAR1829
GAR1834
GAR194C
GAR1926
GAR1929
GAR1934

Tube I.P.S.
1/4

3/8

1/2 - 3/4

1-1/4

1-1/2

2-1/2

Conductor
Rod Size or O.D. Range
1/2

5/8 - 3/4

7/8 - 1

1-1/8 - 1-1/4

1-3/8 - 1-1/2

1-5/8 - 1-7/8

2 - 2-3/8

2-1/2 - 2-7/8

For CUSTOMER SERVICE call 1-800-346-4175

Cable
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500

2-1/2

W
1-7/8

3/8
2-7/8
3-1/2
2-3/4
3
3-3/4
2-7/8

2-1/8
1/2

2-1/2

3/8

2-3/8

1/2

2-3/4

3/8

2-5/8

3-3/8
4-1/2

1/2

3-1/2

3/8

4-1/4

1/2

3-3/8

3/8

3-1/4

4-5/8

1/2

2-5/8

4-1/4

3/8

3-3/4

4-1/2
5-1/4

1/2

4-1/8

3/8

4-1/4

5-5/8

1/2

4-5/8

151

BURNDY
Telecommunications Products
TYPE GAR
(Continued)
FENCE POST GROUNDING
CONNECTOR
Catalog
Number
GAR204C
GAR2026
GAR2029
GAR2034
GAR214C
GAR2126
GAR2129
GAR2134
GAR224C
GAR2226
GAR2229
GAR2234
GAR244C
GAR2426
GAR2429
GAR2434
GAR8629

Tube I.P.S.

Conductor
Rod Size or O.D. Range

3-1/2

5
6

3 - 3-1/2

3-1/2 - 4

4 - 4-1/2

Cable
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
2/0 Sol. - 250

5-5/8

3/8

4-3/4

6-3/8

1/2

5-1/4

6-1/4

3/8

5-3/8

6-3/4

1/2

5-3/4

6-3/8

3/8

5-7/8

6-7/8

1/2

6-1/4

3/8

6-7/8

1/2

7-1/4

1/2

8-3/8

7-3/4
8-5/8
8-13/16

Contact BURNDY for additional pipe and wire size


combinations not shown.

152

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES GAR-BU AND
GAR3902 SERIES
GROUND CONNECTORS
Type GAR-BU is a high-conductivity copper
ground connector for connecting a small to
medium range copper ground conductor to
water pipe as well as structural and reinforcing rod shapes. Universal acceptance of
several sizes of cylindrical shapes makes this
suitable for industrial construction and maintenance work as well as cathodic protection.
Cable clamp swivels to permit parallel
grounding of one pipe or 90 degree cable
run for grounding several parallel pipes.
Single wrench installation. UL467 Listed and
CSA certified.

CATALOG
NUMBER *
GAR3902-BU
GAR3903-BU
GAR3904-BU
GAR3905-BU
GAR3906-BU
GAR3907-BU
GAR3908-BU
GAR3909-BU
GAR3902
GAR3903
GAR3904
GAR3905
GAR3906
GAR3907
GAR3908
GAR3909

CABLE RANGE

#4 - 4/0 AWG

#4 - 4/0 AWG

Features and Benefits


Cable clamp swivels at 90.
Permits parallel grounding of one pipe
or a 90 cable run for grounding several
parallel pipes.
One-wrench installation.
Simplified installation.
DURIUM silicon bronze hardware (-BU
Series)*.
Long lasting corrosion resistance and
acceptable for direct burial in earth
or concrete.
UL467 Listed.
Provides quality assurance to recognized
industry NEC standards from an
independent party.

IPS SIZE

O.D. RANGE

1/2 - 1
1-1/4 - 2
2-1/2 - 3-1/2
4 - 5
6
8
10
12
1/2 - 1
1-1/4 - 2
2-1/2 - 3-1/2
4 - 5
6
8
10
12

.840 - 1.32
1.66 - 2.38
2.88 - 4.00
4.50 - 5.56
6.62
8.62
10.75
12.75
.840 - 1.32
1.66 - 2.38
2.88 - 4.00
4.50 - 5.56
6.62
8.62
10.75
12.75

3.50
4.00
6.50
7.50
8.50
10.00
12.00
14.00
3.50
4.00
6.50
7.50
8.50
10.00
12.00
14.00

3/8 - 16

3/8 - 16

RECOMMENDED
TIGHTENING TORQUE

W
3.25
4.25
6.00
7.50
8.62
10.62
12.75
14.75
3.25
4.25
6.00
7.50
8.62
10.62
12.75
14.75

240 in. - lbs.

240 in. - lbs.

* Type GAR-BU is supplied with DURIUM silicon bronze


hardware and is listed for direct burial.

TYPE GAR-RB
For Reinforcement Bar
CATALOG
NUMBER
GAR644C-RB

REBAR

IPS SIZE

O.D. RANGE

ROD

#3 - 6 (.375 - .750)

3/8

.625 - .75

5/8 - 3/4

COPPER CONDUCTOR
MIN.
MAX.
8 Sol.

4 Str.

UL467 listed for direct burial in earth or concrete.

For CUSTOMER SERVICE call 1-800-346-4175

153

BURNDY
Telecommunications Products
TYPE GAR-TC
WATER PIPE GROUND
CONNECTOR
Type GAR-TC is a high-conductivity copper
ground connector that features a pre-drilled
pad, allowing a 2-hole compression terminal
to be directly connected to water pipe as well
as structural and reinforcing rod shapes.
Universal acceptance of several sizes of
cylindrical shapes makes this suitable for
industrial construction and maintenance work
as well as telecommunications grounding.
Terminal may be mounted parallel, 45 or 90
degrees to the pipe. Acceptable for direct
burial.

Fig. 1

PATENTED

Features and Benefits


DURIUM silicon bronze hardware.
Provide long lasting corrosion resistance
acceptable for direct burial in earth
or concrete.
One-wrench installation.
Simplified installation.
UL467 Listed.
Provides quality assurance to recognized
industry NEC standards from an
independent party. Type GAR-TC is
acceptable for direct burial.

Large, smooth connector contact area


between pipe and ground clamp.
Provides large surface contact area
to maximize contact area between
connector and pipe.
The GAR-TC mounting pad permits
parallel, 45 or 90 angle connections
to the pipe.
Provides maximum flexibility for
field installation.
Pre-drilled pad for (2) 3/8 bolts on
1 centers.
Allows direct mounting of 2-hole
compression terminal up to 750 kcmil
to pipe.

MOUNTING PAD
FOR (2) 3/8"
BOLTS - 1" L
CAST HIGH COPPER ALLOY SADDLE

PIPE DIA.

COMPRESSION LUG WITH PAD


FOR (2) 3/8" DIA. BOLTS
ON 1" CENTERS. 750 KCMIL MAX.

J
MOUNTING PAD
DURIUM 3/8"
SILICON BRONZE
HARDWARE

Fig. 2
CATALOG
NUMBER

FIG.
NO.

GAR3902TC
GAR3903TC
GAR3904TC
GAR3905TC
GAR3906TC
GAR3907TC
GAR3908TC
GAR3909TC

1
1
1
1
1
2
2
2

ACCOMMODATES
I.P.S.
O.D. SIZE
1/2 - 1
1-1/4 - 2
2-1/2 - 3-1/2
4 - 5
6
8
10
12

Add suffix -TNET for electro-tin plated connector and


electro-tin plated DURIUM silicon bronze hardware. Tin
plated catalog number includes mounting hardware for
second bolt hole.
TMH-289 includes (1) 38 x 125 HEB, (1) 38 CHEN, (1) 38
SW and (2) 38 FW. Order separately.

154

.840 - 1.32
1.66 - 2.38
2.88 - 4.00
4.50 - 5.56
6.62
8.62
10.75
12.75

H
3.50
4.00
6.50
7.50
8.50
10.00
12.00
14.00

3/8 - 16

3/8 - 16

3.75
4.75
6.50
8.00
9.12
11.25
13.25
15.25

RECOMMENDED
TIGHTENING TORQUE

240 in. - lbs.

240 in. - lbs.

NOTE: Clean pipe surface beneath saddle until virgin metal is


exposed, install GAR-TC ground connector and for
maximum conductivity, apply PENETROX-E oxide
inhibiting compound around perimeter of the saddle.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE GD
CABLE TO ROD/TUBE
GROUND CONNECTOR
For Two Copper Cables to Rod
or Tube
High copper alloy ground connector for joining a range of two parallel cables to rod or
pipe. Especially good for grounding fence
posts. High copper alloy cast body with
DURIUM U-bolts, nuts, and lockwashers
make the GD suitable for burial in ground or
concrete. One-wrench installation. UL467
Listed. Acceptable for direct burial in earth
or concrete.

Catalog
Number
GD1526
GD1529
GD1626
GD1629
GD174C
GD1726
GD1729
GD1734
GD184C
GD1826
GD1829
GD1834
GD194C
GD1926
GD1929
GD1934
GD204C
GD2026
GD2029
GD2034
GD214C
GD2126
GD2129
GD2134
GD224C
GD2226
GD2229
GD2234

Tube I.P.S.

Conductor
Rod Size or O.D. Range

1-1/8 - 1-1/4

1-1/4

1-3/8 - 1-1/2

1-1/2

1-5/8 - 1-7/8

2-1/2

3-1/2

2 - 2-3/8

2-1/2 - 2-7/8

3 - 3-1/2

3-1/2 - 4

4 - 4-1/2

Cable
4 Sol. - 2/0 Str.
2/0 Sol. - 250
4 Sol. - 2/0 Str.
2/0 Sol. - 250
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500

3-3/8
3-1/2

W
2-5/8
3

3/8
3-1/4

4
4-5/8

1/2

3-5/8

4-3/8

3/8

3-3/4

5-3/8

1/2

4-1/8

3/8

4-1/4

1/2

4-5/8

5-5/8

3/8

4-7/8

6-3/8

1/2

5-1/4

6-1/4

3/8

5-3/8

6-7/8

1/2

5-3/4

6-3/8

3/8

5-7/8

6-7/8

1/2

6-1/4

Complies with NFPA 78-86 HEAVY DUTY stacks.


Add suffix -LD (order: LD for lead plating for HEAVY DUTY
stack applications).

For CUSTOMER SERVICE call 1-800-346-4175

155

BURNDY
Telecommunications Products
TYPE GP
GROUND CONNECTOR
For Two Copper Cables
to Rod or Pipe
High copper alloy ground connector for joining a range of parallel cables perpendicular to
rod, pipe or column. Also used with one
groove for run, the other for tap to equipment.
High copper alloy cast body and DURIUM
U-bolts, nuts, and lockwashers make the GP
suitable for direct burial in the ground or
concrete. One-wrench installation. UL467
Listed. Acceptable for direct burial in earth
or concrete.

Catalog
Number
GP114C
GP1126
GP1129
GP644C
GP6426
GP6429
GP6434
GP144C
GP1426
GP1429
GP1434
GP164C
GP1629
GP1726
GP184C
GP1826
GP2026
GP2226

Tube I.P.S.
1/4

3/8

Conductor
Rod Size or O.D. Range
1/2

5/8 - 3/4

1/2 - 3/4

7/8 - 1

1-1/4

1-5/8

1-1/2

1-7/8

Cable
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2 Sol. - 250
300 - 500
8 Sol. - 4 Str.
2 Sol. - 250
4 Sol. - 2 Str.
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
4 Sol. - 2/0 Str.
4 Sol. - 2/0 Str.

2-3/8

3
4

3-1/2
4-1/2

Tube I.P.S.

Conductor
Rod Size or O.D. Range

W
1-7/8

2-1/2

3/8
2-1/8

2-7/8
3-1/2
2-3/4
3
3-3/4

1/2

2-1/2

38

2-3/8

1/2

2-3/4

3-1/2
4
4-1/8
4-3/8
5-1/2
6-3/8

3
3-1/4
3/8

3-11/16
4-13/16
5-13/16

TYPE GK
GROUND CONNECTOR
For Three Copper Cables to
Rod or Pipe
High copper alloy ground connector for joining three equal cables to rod or tube. Cable
grooves take a wide range of cable. High
copper alloy cast body and DURIUM
U-bolts, nuts, and lockwashers make the GK
suitable for direct burial in soil or concrete.
One-wrench installation. UL467 Listed.
Acceptable for direct burial in earth or
concrete.

156

Catalog
Number
GK114C
GK1126
GK1129
GK644C
GK6426
GK6429
GK6434
GK1426
GK1429
GK1434
GK1526
GK1529
GK1626
GK1629
GK1726
GK1729
GK1826
GK1829
GK1926
GK1929

1/4

3/8

1/2 - 3/4

1/2

5/8 - 3/4

7/8 - 1

1-1/8 - 1-1/4

1-1/4

1-3/8 - 1-1/2

1-1/2

1-5/8 - 1-7/8

2 - 2-3/8

2-1/2

2-1/2 - 2-7/8

Cable
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
8 Sol. - 4 Str.
4 Sol. - 2/0 Str.
2/0 Sol. - 250
300 - 500
4 Sol. - 2/0 Str.
2 Sol. - 250
300 - 500
4 Sol. - 2/0 Str.
2/0 Sol. - 250
4 Sol. - 2/0 Str.
2/0 Sol. - 250
4 Sol. - 2/0 Str.
2/0 Sol. - 250
4 Sol. - 2/0 Str.
2/0 Sol. - 250
4 Sol. - 2/0 Str.
2/0 Sol. - 250

H
2-1/2

J
3/8
1/2

2-7/8
3-1/2
2-3/4

3/8
1/2
38

3-3/4

1/2

3-3/8
3-3/4
3-1/2
4-1/4
4
4-5/8
4-1/4
4-3/8
5
5

3/8
1/2
3/8
1/2
3/8
1/2
3/8
1/2
3/8
1/2

W
2-1/2
2-3/4
3-3/8
2-5/8
3
3-1/2
4
3-1/4
3-7/8
4-3/8
3-1/2
4-1/8
3-7/8
4-1/2
4-1/8
4-3/4
4-5/8
5-1/8
5-1/8
5-5/8

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE GG
GROUND CONNECTOR
For Copper Bar, Strap, Braid or
Cable to Rod or Tube
High copper alloy ground connector for joining bar, strap, braid or cable to rod or tube.
High copper alloy cast body, DURIUM
U-bolts, nuts and lockwashers make the GG
particularly effective for use with braid for
ground rods, switch handles, fence posts and
gates. One-wrench installation.

Catalog
Number
GG15-1
GG16-1
GG17-1
GG17-15
GG18-1
GG18-15
GG18-2
GG19-2
GG19-25
GG20-2
GG20-25
GG20-3
GG21-2
GG21-25
GG21-3
GG21-35
GG22-2
GG22-25
GG22-3
GG22-35
GG22-4
GG24-2

Conductor
Tube I.P.S.

Rod

1
1-1/4

1-1/8 - 1-1/4
1-3/8 - 1-1/2

1-1/2

1-5/8 - 1-7/8

2 - 2-3/8

2-1/2

2-1/2 - 2-7/8

3 - 3-1/2

3-1/2

3-1/2 - 4

4 - 4-1/2

3-1/2
1-1/2
1
1-1/2

2-1/2
2
2-1/2
3
2
2-1/2
3
3-1/2
2
2-1/2
3
3-1/2
4
2

W
2-5/8
3

For CUSTOMER SERVICE call 1-800-346-4175

H
3-3/8

3/8

4-1/4

3-1/4
3-3/4

4-3/8

4-1/8

4-5/8

6-3/8

5-1/4

5-7/8

1/2

5-3/4

6-1/2

6-1/4

7-5/8

7-1/4

157

BURNDY
Telecommunications Products
TYPE B
FLEXIBLE COPPER BRAID
Flexible copper braid jumpers designed to
take up linear expansion and contraction,
compensate for misalignment and absorb
vibratory movement of electrical equipment
and devices.
Made of flat extra flexible, tinned, pure copper
braid, with unplated, seamless, pure copper
ferrules formed into a rectangular shape on
each end.
Last two numbers in catalog number indicate
total length of braid in inches (e.g., BD12N or
BD12 is 12 long braid jumper).
Other lengths, plating and drilling may be
available. Refer to factory.

CATALOG
NUMBER
BD12
BD12N**
BD18
BD18N**
BD24
BD24N**
BE12
BE12N**
BE18
BE18N**
BE24
BE24N**
BF12
BF12N**
BF18
BF18N**
BF24
BF24N**
BG12
BG12N**
BG18
BG18N**
BG24
BG24N**

NUMBER OF
BRAIDS IN
FERRULES

.94

2.50
3.00
2.50
3.00
2.50
3.00

1.25
1.75
1.25
1.75
1.25
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75

.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56

12
12
18
18
24
24
12
12
18
18
24
24
12
12
18
18
24
24
12
12
18
18
24
24

1.50

3.00

1.19

3.00

1.50

3.00

APPROXIMATE AMP *
INDOOR
OUTDOOR

.62

.13

190

225

.17

340

405

.25

360

430

.25

415

495

.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.75
.62

* This rating may vary with ambient conditions, orientation of


the braid and other service conditions.
** Tongue drilled per (2) hole NEMA standard.

158

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
FLEXIBLE COPPER
BRAID
(Continued)
TYPE B
CATALOG
NUMBER
B2D12
B2D12N**
B2E12
B2E12N**
B2F12
B2F12N**
B2G12
B2G12N**
B3D12
B3D12N**
B3E12
B3E12N**
B3F12
B3F12N**
B3G12
B3G12N**
B4D12
B4D12N**
B4E12
B4E12N**
B4F12
B4F12N**
B4G12
B4G12N**

NUMBER OF
BRAIDS IN
FERRULES

C
.94
1.62

2
1.38
1.50
1.19
1.64
3
1.44
1.69
1.19
1.64
4
1.50
1.69

2.50
3.00
3.00
3.00
3.00
3.00
3.00
3.00
2.50
3.00
3.00
3.00
3.00
3.00
3.00
3.00
2.50
3.00
3.00
3.00
3.00
3.00
3.00
3.00

1.25
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.25
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.25
1.75
1.50
1.75
1.50
1.75
1.50
1.75

.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

.62
.62
.75
.62
.75
.62
.75
.62
.62
.62
.75
.62
.75
.62
.75
.62
.62
.62
.75
.62
.75
.62
.75
.62

APPROXIMATE AMP *
INDOOR
OUTDOOR

.25

380

455

.25

530

635

.38

600

720

.50

700

840

.25

470

560

.31

700

840

.56

820

980

.69

960

1150

.32

600

720

.36

850

1020

.78

1000

1200

.94

1200

1440

* This rating may vary with ambient conditions, orientation of


the braid and other service conditions.
** Tongue drilled per (2) hole NEMA standard.

For CUSTOMER SERVICE call 1-800-346-4175

159

BURNDY
Telecommunications Products
TYPE GRF
UNIGROUND RAISED FLOOR
GROUNDING CONNECTOR
The BURNDY UNIGROUND is a universal
grounding clamp, specifically designed for all
raised flooring systems. It can be installed on
round or square pedestals and can
accommodate one or two grounding wires to
make an efficient grid. The underfloor signal
reference grid provides the low impedance
ground path that attenuates high frequency
static and 60 Hz transient noise for cleaner
data output. UL467 Listed.

CATALOG
NUMBER
GRF4C-3
GRF4C-4

160

Features and Benefits


One connector fits all applications.
Ease of specification and installation.
Single bolt design.
Ease of installation:
No need to disassemble.
Single wrench installation.
Accepts 1 or 2 ground conductors.
Requires less connectors to install
signal reference grid.
Tin plated cast bronze construction.
Resists corrosion and provides extended
life ground connection.

NUMBER OF
CONDUCTORS

CONDUCTOR
SIZE SOL. & STR.

1 or 2
1 or 2

#8 - #2
#8 - #2

PEDESTAL TYPE
ROUND
SQUARE
Up to 1
Up to 3/4

Up to 7/8
Up to 5/8

Grounds all pedestals (round or square).


Will handle up to 7/8 square and 1 round.
Ease of installation. One connector
does it all.
Serves 3 needs:
1. Signal Reference Grid.
2. Static Ground.
3. Fault Current Ground.
UNIGROUND solves possible grounding problems found in computer applications today.

1.96
1.79

3.14
3.13

3/8
3/8

1.76
1.40

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES GP-G1, GP-RT
RAISED FLOOR
GROUNDING CLAMPS
High copper alloy ground connector for raised
floor computer grounding applications. These
connectors can be installed on round and
square pedestal applications and will accommodate one or two grounding wires to make
an efficient grid. The underfloor signal reference grid provides the low impedance ground
path that attenuates high frequency static and
60 Hz transient noise for cleaner data output.
UL467 Listed.
In addition we offer the GP1726RT, which is
especially designed for penetrating epoxy
paint on pedestals. This patented connector
offers a low impedance, time saving connection between conductors and the pedestal.

GP1726RT

Features and Benefits


Accepts 1 or 2 Ground Conductors
Requires less connectors to install signal
reference grid.
Made of copper alloy.
DURIUM U-Bolts, nuts and lockwashers.
Provides a low impedance ground path
for maximum performance.
Grounds all pedestals (round or square).
Will handle from 34 to 1 round or square.
Ease of installation.
Serves 3 needs.
1. Signal Reference Grid.
2. Static Ground.
3. Fault Current Ground.
Connectors solves possible grounding
problems found in computer applications
today.

CATALOG
NUMBER

NUMBER OF
CONDUCTORS

CONDUCTOR
SIZE SOL. & STR.

PEDESTAL TYPE
ROUND OR SQUARE

GP654CG1
GP64526G1
GP1526G1
GP1726RT

1 or 2
1 or 2
1 or 2
1 or 2

#8 Sol. - 4 Str.
#4 Sol. - 2/0 Str.
#4 Sol. - 2/0 Str.
#6 Sol. - 2/0 Str.

3/4 - 1 Round
3/4 - 1 Square
1-1/4 Round
2 Round

1.5
1.5
1.75
2.12

3/8
3/8
3/8
3/8

1.31
1.69
1.69
1.50

2.38
2.38
2.62
3.22

For CUSTOMER SERVICE call 1-800-346-4175

161

BURNDY
Telecommunications Products
DURIUM BOLT
SILICON BRONZE
BURNDY introduced silicon-bronze bolts,
nuts, and other hardware items on outdoor
connector applications in 1927. Today the
DURIUM trademark is a standard for
this use.
DURIUM bolts combine high strength with
corrosion resistance. Bolts up to 2 inches
long are fully threaded; longer bolts are
threaded for two inches. Heads have
American Standard dimension, and the
threads are per American National Coarse
Series, Class #2 fit. The silicon bronze is per
ASTM B99.

Catalog Number

Thread
Size

B
Length

Catalog Number

Thread
Size

B
Length

Catalog Number

Thread
Size

B
Length

25x50 HEB BOX


25x62 HEB BOX
25x75 HEB BOX
25x100 HEB BOX
25x125 HEB BOX
25x150 HEB BOX
25x200 HEB BOX
25x250 HEB BOX
25x300 HEB BOX
31x50 HEB BOX
31x62 HEB BOX
31x75 HEB BOX
31x100 HEB BOX
31x125 HEB BOX
31x150 HEB BOX
31x175 HEB BOX
31x200 HEB BOX
31x250 HEB BOX
31x300 HEB BOX
38x50 HEB BOX
38x62 HEB BOX
38x75 HEB BOX
38x88 HEB BOX
38x100 HEB BOX

1/4-20
1/4-20
1/4-20
1/4-20
1/4-20
1/4-20
1/4-20
1/4-20
1/4-20
5/16-18
5/16-18
5/16-18
5/16-18
5/16-18
5/16-18
5/16-18
5/16-18
5/16-18
5/16-18
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16

1/2
5/8
3/4
1
1-1/4
1-1/2
2
2-1/2
3
1/2
5/8
3/4
1
1-1/4
1-1/2
1-3/4
2
2-1/2
3
1/2
5/8
3/4
7/8
1

38x125 HEB BOX


38x150 HEB BOX
38x175 HEB BOX
38x200 HEB BOX
38x225 HEB BOX
38x250 HEB BOX
38x275 HEB BOX
38x300 HEB BOX
38x325 HEB BOX
38x350 HEB BOX
38x400 HEB BOX
38x450 HEB BOX
38x500 HEB BOX
44x150 HEB BOX
44x200 HEB BOX
50x75 HEB BOX
50x100 HEB BOX
50x125 HEB BOX
50x150 HEB BOX
50x175 HEB BOX
50x200 HEB BOX
50x225 HEB BOX
50x250 HEB BOX
50x275 HEB BOX

3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
7/16-14
7/16-14
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13

1-1/4
1-1/2
1-3/4
2
2-1/4
2-1/2
2-3/4
3
3-1/4
3-1/2
4
4-1/2
5
1-1/2
2
3/4
1
1-1/4
1-1/2
1-3/4
2
2-1/4
2-1/2
2-3/4

50x300 HEB BOX


50x325 HEB BOX
50x350 HEB BOX
50x375 HEB BOX
50x400 HEB BOX
50x450 HEB BOX
50x500 HEB BOX
50x550 HEB BOX
50x600 HEB BOX
62x100 HEB BOX
62x125 HEB BOX
62x150 HEB BOX
62x175 HEB BOX
62x200 HEB BOX
62x225 HEB BOX
62x250 HEB BOX
62x275 HEB BOX
62x300 HEB BOX
62x325 HEB BOX
62x350 HEB BOX
62x400 HEB BOX
62x450 HEB BOX
62x500 HEB BOX
62x600 HEB BOX

1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
1/2-13
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11
5/8-11

3
3-1/4
3-1/2
3-3/4
4
4-1/2
5
5-1/2
6
1
1-1/4
1-1/2
1-3/4
2
2-1/4
2-1/2
2-3/4
3
3-1/4
3-1/2
4
4-1/2
5
6

DURIUM NUT
SILICON BRONZE
DURIUM hexagon regular nuts are nonmagnetic and are made to American
Standard dimensions. American National
Coarse Series threads, #2 fit.

162

Catalog Number

Thread Size

25C HEN BOX


31C HEN BOX
38C HEN BOX
44C HEN BOX
50C HEN BOX
62C HEN BOX
75C HEN BOX

1/4-20
5/16-18
3/8-16
7/16-14
1/2-13
5/8-11
3/4-10

BURNDY
Telecommunications Products
DURIUM SPLIT
LOCKWASHER
SILICON BRONZE
DURIUM spring type lockwasher has high
resiliency and exerts constant pressure on
the face of the nut, preventing vibration from
loosening the nut.

DURIUM
INTERNAL TOOTH
LOCKWASHER
SILICON BRONZE

Catalog Number

For Bolt Size

25 SW BOX
31 SW BOX
38 SW BOX
44 SW BOX
50 SW BOX
62 SW BOX

1/4
5/16
3/8
7/16
1/2
5/8

Catalog Number

For Bolt Size

25 NW BOX
31 NW BOX
38 NW BOX
44 NW BOX
50 NW BOX
62 NW BOX

1/4
5/16
3/8
7/16
1/2
5/8

DURIUM Internal Tooth Lockwashers are


available as illustrated. The teeth are twisted
slightly and present biting edges which grip
the nut and the part being clamped, preventing the nut from backing off.

DURIUM
FLAT WASHER
SILICON BRONZE
High strength DURIUM Flat Washers are
non-magnetic and free from galvanic action
when in contact with copper. Conforms to
SAE standards.

For CUSTOMER SERVICE call 1-800-346-4175

Catalog Number

For Bolt
Size

25 FW BOX
31 FW BOX
38 FW BOX
44 FW BOX
50 FW BOX
62 FW BOX

1/4
5/16
3/8
7/16
1/2
5/8

Nominal Dimensions in Inches


A
B
1/16
1/16
1/16
1/16
3/32
3/32

5/8
11/16
13/16
15/16
1-1/16
1-5/16

163

BURNDY
Telecommunications Products
TYPE TMH
DURIUM SILICON BRONZE
HARDWARE KITS
Type TMH are DURIUM silicon bronze
hardware kits. The kits can be ordered for
specific applications ensuring the proper type
and amount of hardware for each installation.
Packaged in separate sealed bags, they are
convenient to use, eliminating mismatched
quantities. DURIUM silicon bronze material
provides long lasting corrosion resistance.

Catalog
Number
TMH262
TMH263
TMH264
TMH265
TMH323
TMH266
TMH267
TMH268
TMH269
TMH270
TMH271
TMH332 2
TMH261
TMH289
TMH295
TMH272
TMH294
TMH69

Size

1/4-20

3/8-16

1/2-13

Bolt
Length
0.75
1.00
1.25
1.50
0.75
0.75
1.00
1.25
1.50
1.75
2.00
2.75
3.00
1.25
1.25
1.50
1.75
2.00

Each TMH Kit Includes:


Flat
Split
Qty.
Washer Washer
2
4
2
2
4
2
2
4
2
2
4
2
1
0
1
2
4
2
2
4
2
2
4
2
2
4
2
2
4
2
2
4
2
2
4
2
2
4
2
1
2
1
2
4
2
2
4
2
2
4
2
2
4
2

For use with CUSA750-2TC38 copper spacer adaptor, (2)


terminals and " thick equipment bus bar.
For other combinations contact BURNDY.
For use with all GAR-TC connectors. "R" dimension is
allowable pad thickness of terminal

TYPE TMH-SS
STAINLESS STEEL
HARDWARE KITS
Type TMH-SS are Grade 5 stainless steel
hardware kits. Just like the standard TMH kits,
these kits can be ordered for specific applications ensuring the proper type and amount of
hardware for each installation. They are packaged in separate sealed bags and convenient
for use and ordering.

Catalog
Number
TMH322SS
TMH262SS
TMH263SS
TMH264SS
TMH265SS
TMH323SS
TMH266SS
TMH267SS
TMH268SS
TMH269SS
TMH270SS
TMH271SS
TMH261SS
TMH289SS
TMH295SS
TMH272SS
TMH294SS
TMH69SS

Size
10 - 32

1/4-20

3/8-16

1/2-13

Hex
Nut
2
2
2
2
1
2
2
2
2
2
2
2
2
1
2
2
2
2

Working
Range
R
0.09 - 0.34
0.34 - 0.59
0.59 - 0.84
0.84 - 1.09

0.00 - 0.19
0.19 - 0.44
0.44 - 0.69
0.69 - 0.94
0.94 - 1.19
1.19 - 1.44

2.15 - 2.40
0.02 - 0.27
0.27 - 0.49
0.49 - 0.74
0.74 - 0.99
0.99 - 1.24

Installation
Torque
(In-lbs)

80

240

480

* For other combinations contact BURNDY.


"L" dimension never exceeds .25"
2 For use with CUSA442TC38 on 1/4" bus bar and
HYLUG 4/0 - 750 kcmil.

Each TMH Kit Includes:


Bolt
Flat
Split
Length Qty.
Washer Washer
0.875
1
0
1
0.75
2
4
2
1.00
2
4
2
1.25
2
4
2
1.50
2
4
2
0.75
1
0
1
0.75
2
4
2
1.00
2
4
2
1.25
2
4
2
1.50
2
4
2
1.75
2
4
2
2.00
2
4
2
3.00
2
4
2
1.25
1
2
1
1.25
2
4
2
1.50
2
4
2
1.75
2
4
2
2.00
2
4
2

Hex
Nut
1
2
2
2
2
1
2
2
2
2
2
2
2
1
2
2
2
2

Working
Range
R

0.09 - 0.34
0.34 - 0.59
0.59 - 0.84
0.84 - 1.09

0.00 - 0.19
0.19 - 0.44
0.44 - 0.69
0.69 - 0.94
0.94 - 1.19
1.19 - 1.44
2.15 - 2.40
0.02 - 0.27
0.27 - 0.49
0.49 - 0.74
0.74 - 0.99
0.99 - 1.24

Installation
Torque
(In-lbs)
45

80

240

480

For use with CUSA750-2TC38 copper spacer adaptor, (2)


terminals and " thick equipment bus bar.
For other combinations contact BURNDY.
For use with all GAR-TC connectors. "R" dimension is
allowable pad thickness of terminal

164

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
UNIRAP
STANDARD CABLE TIES

18 Lb. Minimum
Tensile Strength
STANDARD
PACKAGE
CATALOG
NUMBER
CT18075C
CT18075C0
CT18125C
CT18125C0
CT18200C
CT18200C0

MATERIAL
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

.75 [19]
1.25 [32]

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION
TOOL

TOOL
SETTING

4.00 [102]
18 (80)

2.00 [51]

5.67 [144]

.10 [2.5]

TWT1, MK7

Mini

8.00 [203]

BULK
PACKAGE
CATALOG
NUMBER
CT18075M
CT18075M0
CT18125M
CT18125M0
CT18200M
CT18200M0

30 Lb. Minimum
Tensile Strength
STANDARD
PACKAGE
CATALOG
NUMBER
CT30125C
CT30125C0

MATERIAL
Natural Nylon 6/6
Black Nylon 6/6 UV

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION
TOOL

TOOL
SETTING

1.25 [32]

30 (133)

6.00 [152]

.14 [3.6]

TWT1, MK7

Intermediate

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

BULK
PACKAGE
CATALOG
NUMBER
CT30125M
CT30125M0

40 Lb. Minimum
Tensile Strength
STANDARD
PACKAGE
CATALOG
NUMBER
CT40200C
CT40200C0
CT40300C
CT40300C0
CT40400C
CT40400C0

MATERIAL
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

2.00 [51]
3.00 [76]

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION
TOOL

TOOL
SETTING

8.50 [216]
40 (178)

4.00 [102]

11.50 [292]

.15 [3.8]

TWT1, MK7

Intermediate

14.50 [368]

BULK
PACKAGE
CATALOG
NUMBER
CT40200M
CT40200M0
CT40300M
CT40300M0
CT40400M
CT40400M0

50 Lb. Minimum
Tensile Strength
STANDARD
PACKAGE
CATALOG
NUMBER
CT50175C
CT50175C0
CT50300C
CT50300C0
CT50400C
CT50400C0

MATERIAL
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

1.75 [44]
3.00 [76]
4.00 [102]

For CUSTOMER SERVICE call 1-800-346-4175

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION
TOOL

TOOL
SETTING

8.00 [203]
50 (222)

11.75 [298]
15.50 [394]

.18 [4.6]

TWT1, MK7

Standard

BULK
PACKAGE
CATALOG
NUMBER
CT50175M
CT50175M0
CT50300M
CT50300M0
CT50400M
CT50400M0

165

BURNDY
Telecommunications Products
UNIRAP
STANDARD CABLE TIES
(Continued)

120 Lb. Minimum


Tensile Strength
STANDARD
PACKAGE
CATALOG
NUMBER

MATERIAL

CT120200L
CT120200L0
CT120300L
CT120300L0
CT120400L
CT120400L0
CT120900L
CT120900L0

Natural Nylon 6/6


Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

2.00 [51]

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION
TOOL

TOOL
SETTING

8.87 [226]

3.00 [76]

11.87 [302]
120 (534)

.30 [7.6]

4.00 [102]

15.25 [387]

9.00 [229]

29.75 [776]

TWT2, MK9

Standard

BULK
PACKAGE
CATALOG
NUMBER
CT120200D
CT120200D0
CT120300D
CT120300D0
CT120400D
CT120400D0
CT120900D
CT120900D0

175 Lb. Minimum


Tensile Strength
STANDARD
PACKAGE
CATALOG
NUMBER

MATERIAL

CT175400Q
CT175400Q0
CT175600Q
CT175600Q0
CT175900Q
CT175900Q0
CT1751100Q
CT1751100Q0
CT1751400Q
CT1751400Q0

Natural Nylon 6/6


Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

4.00 [102]

15.00 [381]

6.00 [152]

21.00 [533]

9.00 [229]

175 (778)

32.00 [813]

11.00 [279]

36.00 [914]

14.00 [356]

52.00 [1321]

WIDTH
In. [mm]

.35 [8.9]

INSTALLATION
TOOL

TWT2, MK9

TOOL
SETTING

Heavy

BULK
PACKAGE
CATALOG
NUMBER

250 Lb. Minimum


Tensile Strength
STANDARD
PACKAGE
CATALOG
NUMBER

MATERIAL

CT250600Q
CT250600Q0
CT250800Q
CT250800Q0
CT2501000Q
CT2501000Q0
CT2501200Q
CT2501200Q0

Natural Nylon 6/6


Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

166

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

6.00 [152]

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION
TOOL

TOOL
SETTING

23.00 [584]

8.00 [203]

29.00 [737]
250 (1112)

.50 [12.7]

10.00 [254]

35.00 [889]

12.00 [305]

40.00 [1016]

TWT2, MK9

Heavy

BULK
PACKAGE
CATALOG
NUMBER

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
UNIRAP
RELEASABLE CABLE TIES
Perfect for prototype construction, releasable
cable ties are ideal for temporary installations. Releasable ties are also good for
applications where service requires adding or
subtracting wires from an existing wire
bundle.

Standard Releasable Ties

Extended Pawl Releasable Ties

Standard Releasable Cable Ties


STANDARD
PACKAGE
CATALOG
NUMBER

MATERIAL

CT40200RC
CT40200RC0
CT50137RC
CT50137RC0
CT50400RC
CT50400RC0

Natural Nylon 6/6


Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

WIDTH
In. [mm]

2.00 [51]

40 (178)

8.50 [216]

.16 [4]

1.38 [35]

6.50 [165]
50 (222)

4.00 [102]

.18 [4.6]
15.50 [394]

Extended Pawl
Releasable Cable Ties
STANDARD
PACKAGE
CATALOG
NUMBER
CT50137EPRC
CT50137EPRC0
CT50250EPRC
CT50250EPRC0

MATERIAL
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

1.38 [35]

LENGTH
In. [mm]

WIDTH
In. [mm]

5.50 [140]
50 (222)

2.50 [64]

.291 [7.4]
9.80 [249]

Heavy Duty
Releasable Cable Ties
STANDARD
PACKAGE
CATALOG
NUMBER
CT250200RQ
CT250200RQ0
CT250500RQ
CT250500RQ0
CT250600RQ
CT250600RQ0
CT250800RQ
CT250800RQ0
CT2501000RQ
CT2501000RQ0
CT2501200RQ
CT2501200RQ0

MATERIAL
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

For CUSTOMER SERVICE call 1-800-346-4175

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

2.00 [51]

9.00 [229]

5.00 [127]

20.00 [508]

6.00 [152]

WIDTH
In. [mm]

23.00 [584]
250 (1112)

.50 [12.7]

8.00 [203]

29.00 [737]

10.00 [254]

35.00 [889]

12.00 [305]

40.00 [1016]

167

BURNDY
Telecommunications Products
UNIRAP
IDENTIFICATION CABLE TIES
Identification cable ties are used in both
bundling and identifying wire groups at the
same time.

STANDARD
PACKAGE
CATALOG
NUMBER
CT18075IDC
CT18075FLC
CT50175IDC
CT50175ID2L
CT50175ID3L
CT50400IDC

MATERIAL

FIG. NO.

MARKING PAD SIZE


In. [mm]

Natural Nylon 6/6

1
2
3
4
5
6

1  19/64 [25.4  7.5]


13/16  5/16 [20.5  7.9]
1  7/16 [25.4  11.1]
1-11/16  5/16 [29.8  23.8]
1-13/16  15/16 [46  23.8]
1/2  2-1/8 [12.7  54]

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

.75 [19]

18 (80)

1.75 [44]

WIDTH
In. [mm]

INSTALLATION
TOOL
& (SETTING)

4.00 [102]
4.25 [108]

.10 [2.5]

MK7 (MIN)

.18 [4.6]

MK7 (STD)

8.00 [203]

50 (222)

4.00 [107]

LENGTH
In. [mm]

15.00 [381]

UNIRAP
MOUNTING HOLE
CABLE TIES
STANDARD
PACKAGE
CATALOG
NUMBER
CT18075MH4C
CT18075MH4C0
CT30125MH8C
CT30125MH8C0
CT50175MH10C
CT50175MH10C0
CT50400MH10C
CT50400MH10C0
CT120400MH14L
CT120400MH14L0

168

MATERIAL
Natural Nylon 6/6
Black Nylon 6/6 UV
Nylon 6/6
Nylon 6/6 UV
Nylon 6/6
Nylon 6/6 UV
Nylon 6/6 GP
Nylon 6/6 UV
Nylon 6/6
Nylon 6/6 UV

SCREW
SIZE

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION
TOOL
& (SETTING)

#4 (M2,5)

.75 [19]

18 (80)

4.25 [108]

.10 [2.5]

MK7 (MIN)

#8 (M4)

1.25 [32]

30 (133)

6.25 [159]

.14 [3.6]

MK7 (INT)

#10 (M5)

1.75 [44]

50 (222)

8.50 [216]
.18 [4.6]

MK7 (STD)

#10 (M5)

4.00 [102]

50 (222)

16.00 [406]

1/4 (M6)

4.00 [102]

120 (534)

16.25 [413]

.30 [7.6]

MK9 (STD)

BULK
PACKAGE
CATALOG
NUMBER
CT18075MH4M
CT18075MH4M0
CT30125MH8M
CT30125MH8M0
CT50175MH10M
CT50175MH10M0
CT50400MH10M
CT50400MH10M0
CT120400MH14D
CT120400MH14D0

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
UNIRAP
HALAR TIES
Halar ties meet NEC regulations and can be
used in applications where low smoke and
low flame are a concern, as in air handling
spaces. The raw material used to manufacture FCI BURNDY Halar cable ties is
UL 94V-0 rated. These ties come in a distinct
color of red for easy identification.

Halar Cable Ties


STANDARD
PACKAGE
CATALOG
NUMBER
CTH18075C
CTH30200C
CTH50175C
CTH120400L

MATERIAL
Halar

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

WIDTH
In. [mm]

.75 [19]
2.00 [51]
1.75 [44]
4.00 [102]

18 (80)
30 (133)
50 (222)
120 (534)

4.00 [102]
8.00 [203]
8.00 [203]
15.25 [387]

.10 [2.5]
.14 [3.6]
.18 [4.6]
.18 [4.6]

INSTALLATION TOOL

TOOL
SETTING

MK7

Mini
Intermediate

MK9

Standard

BULK
PACKAGE
CATALOG
NUMBER
CTH18075M
CTH30200M
CTH50175M
CTH120400D

UNIRAP
TEFZEL TIES
Tefzel ties provide excellent protection
against radiation, ultraviolet light, and a wide
range of chemicals. It is also rated for low outgassing applications. FCI BURNDY Tefzel
ties offer temperature stability to 150 C and
come in a standard color of blue for easy
identification.

Tefzel Cable Ties


STANDARD
PACKAGE
CATALOG
NUMBER
CTZ18075C
CTZ30200C
CTZ50175C
CTZ120400L

MATERIAL
Tefzel

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

WIDTH
In. [mm]

.75 [19]
2.00 [51]
1.75 [44]
4.00 [102]

18 (80)
30 (133)
50 (222)
120 (534)

4.00 [102]
8.00 [203]
8.00 [203]
15.25 [387]

.10 [2.5]
.14 [3.6]
.18 [4.6]
.18 [4.6]

For CUSTOMER SERVICE call 1-800-346-4175

INSTALLATION TOOL

TOOL
SETTING

MK7

Mini
Intermediate

MK9

Standard

BULK
PACKAGE
CATALOG
NUMBER
CTZ18075M
CTZ30200M
CTZ50175M
CTZ120400D

169

BURNDY
Telecommunications Products
UNIRAP
PUSH MOUNT CABLE TIES
Standard Push Mount Ties
STANDARD
PACKAGE
CATALOG
NUMBER

MATERIAL

MOUNTING
HOLE DIA.
In. [mm]

CT30125PMC
CT30125PMC0
CT50175PMC
CT50175PMC0

Natural Nylon 6/6


Black Nylon 6/6 UV
Natural Nylon 6/6
Black Nylon 6/6 UV

.187 - .220
[4.8 - 5.6]
.250 - .280
[6.4 - 7]

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION
TOOL
& (SETTING)

1.25 [32]

30 (133)

6.50 [165]

.14 [3.6]

MK7 (INT)

1.75 [44]

50 (222)

8.50 [216]

.18 [4.6]

MK7 (STD)

BULK
PACKAGE
CATALOG
NUMBER
CT30125PMM
CT30125PMM0
CT50175PMM
CT50175PMM0

UNIRAP
STAINLESS STEEL TIES
BURNDY's Stainless Steel ties are designed
to secure hoses, cables, poles, pipes, and
more when harsh environmental conditions
may adversely affect the bundling application.
Used where corrosion, vibration, weathering,
radiation, and temperature extremes are a
concern, BURNDY's Stainless Steel ties can
be used in virtually any indoor, outdoor, and
underground application.

Features

BURNDY Stainless Steel ties are made from


Grade 304 Stainless Steel. This tie is
designed with a low profile clamping bearing
head with fully adjustable strap accommodating many bundle diameters.

STANDARD
PACKAGE
CATALOG
NUMBER
CTSS100200C
CTSS100400C
CTSS100600C
CTSS100800C
CTSS1001000C
CTSS250200L
CTSS250400L
CTSS250600L
CTSS250800L
CTSS2501000Q

170

MATERIAL

304 SS

304 SS

MAXIMUM
BUNDLE
DIAMETER
In. [mm]
1.96 [50]
3.93 [100]
5.90 [150]
7.87 [200]
9.84 [250]
1.96 [50]
3.93 [100]
5.90 [150]
7.87 [200]
9.84 [250]

Smooth, rounded edges help ensure safe,


efficient handling.
Ergonomically designed installation tool
consistently tensions and cuts off ties
leaving flush edges.
Flame retardant and non-toxic for applications where safety from fire is critical.

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

100 (444)

250 (1112)

LENGTH
In. [mm]
7.90 [201]
14.30 [363]
20.50 [521]
26.80 [681]
33.00 [838]
7.90 [201]
14.30 [363]
20.50 [521]
26.80 [681]
33.00 [838]

HEAD
WIDTH
In. [mm]

STRAP
WIDTH
In. [mm]

INSTALLATION
TOOL
& (SETTING)

.26 [4.6]

.18 [4.6]

MK9SST (INT)

.39 [9.8]

.31 [7.9]

MK9SST (STD)

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
UNIRAP
AERIAL SUPPORT
SPACER TIES
Aerial Support Spacer ties are one-piece ties
designed for standard spacing applications.
These ties are pre-grouped in handy
multiples of 5 to save installation time. The
strap is molded from special high impact
nylon 6/6. The spacers are made from a highdensity outdoor black polypropylene. Both
materials in this one-piece tie offer resistance
to sunlight, saltwater, and harsh chemical
environments.

STANDARD
PACKAGE
CATALOG
NUMBER
CTAS750
CTAS1000
CTAS1600

MATERIAL

MAXIMUM
BUNDLE
DIAMETER
In. [mm]

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION TOOL
& (SETTING)

Polypropylene
Polypropylene
Polypropylene

1.75 [44]
2.75 [70]
4.50 [114]

100 (445)
100 (445)
100 (445)

7.5 [190]
10.00 [254]
16.00 [406]

.50 [12.7]

MK9 (INT)

UNIRAP
EXTENDED LENGTH TIES
BURNDY Extended Length ties are a high
strength strapping system used for supporting, securing, fastening, and spacing cable,
as well as a variety of other applications
requiring extra long, extremely durable
strapping.
The Extended Length tie consists of a smooth
strap and a separate, compact plastic head,
which encloses a stainless steel gripper. The
stackable spacer works with the Extended
Length tie for a versatile, easy to install
spacing system. It has a minimum loop
tensile strength of 250 pounds and has a
continuous operating temperature range of
40 C to 85 C.

STANDARD
PACKAGE
CATALOG
NUMBER
BETHEAD
BETSPACER
BETSTRAP
BET13
BET27

The Extended Length tie complies with


Bellcore Specification Reference TR-TSY00789. The Extended Length strap and head
are manufactured from black, acetal
homopolymer with excellent dielectric properties, UV and chemical resistance, with a
UL94-HB flame rating. It has been tested for
excellent weatherability against moisture,
sunlight, and other environmental conditions.

MATERIAL

DESCRIPTION

Acetal

Double entry double locking heads


Spacer
Strap on reel
13.5 inches of strap and double locking head
27 inches of strap and double locking head

For CUSTOMER SERVICE call 1-800-346-4175

MINIMUM
TENSILE
STRENGTH
Lbs. (N)

250 (1112)

LENGTH
In. [mm]

WIDTH
In. [mm]

INSTALLATION TOOL
& (SETTING)

.80 [20.3]
2.10 [53.3]
50 ft. [15.24 m]
13.50 [343]
27.00 [686]

.62 [15.7]
1.20 [30.5]

.50 [12.7]

MK9 (INT)

171

BURNDY
Telecommunications Products
TYPE TFV-B
UNIRAP
HOOK AND LOOP STRAPS
Reusable and flexible BURNDY Hook and
Loop Straps are a unique self-gripping
fastening system. Cables can be added or
subtracted easily.
The TFV-V2 series straps are UL Listed Wire
Positioning Devices (ZODZ), UL94-V2 rated
for use in air handling spaces in accordance
with the NEC section 300-22 (c) and (d).
Perfect for plenum areas.

CATALOG
NUMBER
TFV3B12V2**
TFV3B18V2**
TFV3BLU12
TFV3BLU18

PRODUCT DESCRIPTION

VELCRO hook and loop strap, 3/4  12, Black, 25pk


VELCRO hook and loop strap, 3/4  18, Black, 25pk
VELCRO hook and loop strap, 3/4  12, Royal Blue, 25pk
VELCRO hook and loop strap, 3/4  18, Royal Blue, 25pk

0.75
0.75
0.75
0.75

12.00
18.00
12.00
18.00

.50
.50
.50
.50

.09
.09
.09
.09

MAX.
AVG. SHEER AVG. PEEL PKG.
BUNDLE DIA.
(PSI)
(PIW)
QTY.
3.0
5.0
3.0
5.0

29
29
23
23

.6
.6
.5
.5

*1
*1
*1
*1

* Straps sold by the package, quantity 1 package equals 25


straps.
** UL94-V2 listed.
VELCRO is a registered trademark of Velcro USA, Inc.

172

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
MOUNTING BASES
BURNDY offers a wide variety of mounting
bases suited for many applications. Mounting
bases are used in conjunction with cable ties
to stabilize and secure wire bundles, both
indoors and outdoors. Mounting bases can be
secured to a surface using rubber based
adhesive, acrylic adhesive, or also can be
screw mounted.
BURNDYs 4-way mounting bases are available in four sizes to accommodate CT18
through CT150 series cable ties. Insertion of
ties can be made from all sides. Each mount
may be secured with two screws, with
adhesive backing, or both, for ease of application and stability. For applications where
higher temperatures, certain chemicals, or
UV radiation are a concern and an adhesive
is the preferred method for securing, the
acrylic adhesive 4-way mounting bases are
recommended.

The 2-way mounting bases may be secured


with one screw, with adhesive backing, or
both, and allow ties to be inserted from two
sides.

4-Way
CATALOG
NUMBER
CTB075S4C
CTB075S4M
CTB075AA4C
CTB075AA4M
CTB075RA4C
CTB075RA4M
CTB125S4C
CTB125S4D
CTB125AA4C
CTB125AA4D
CTB125RA4C
CTB125RA4L
CTB125RA4D
CTB150S4C
CTB150S4B
CTB150AA4C
CTB150AA4B
CTB150RA4C
CTB150RA4B

MOUNTING
METHOD

MAX. TIE
SLOT WIDTH

DIMENSION
A

DIMENSION
B

DIMENSION
C

PKG.
QTY.

#4 Screw
#4 Screw
Acrylic Adhesive
Acrylic Adhesive
Rubber Adhesive
Rubber Adhesive
#8 Screw
#8 Screw
Acrylic Adhesive
Acrylic Adhesive
Rubber Adhesive
Rubber Adhesive
Rubber Adhesive
#8 Screw
#8 Screw
Acrylic Adhesive
Acrylic Adhesive
Rubber Adhesive
Rubber Adhesive

.14
.14
.14
.14
.14
.14
.20
.20
.20
.20
.20
.20
.20
.35
.35
.35
.35
.35
.35

.75
.75
.75
.75
.75
.75
1.125
1.125
1.125
1.125
1.125
1.125
1.125
1.5
1.5
1.5
1.5
1.5
1.5

.75
.75
.75
.75
.75
.75
1.125
1.125
1.125
1.125
1.125
1.125
1.125
1.5
1.5
1.5
1.5
1.5
1.5

.15
.15
.15
.15
.15
.15
.19
.19
.19
.19
.19
.19
.19
.25
.25
.25
.25
.25
.25

100
1000
100
1000
100
1000
100
500
100
500
100
50
500
100
250
100
250
100
250

MOUNTING
METHOD

MAX. TIE
SLOT WIDTH

DIMENSION
A

DIMENSION
B

DIMENSION
C

PKG.
QTY.

#6 Screw
Rubber Adhesive

.18
.18

1.125
1.125

1.125
1.125

.21
.21

100
100

All bases listed above are natural. UV Black mounting bases


are also available in nearly every size, insert 0 after the part
number.

2-Way
CATALOG
NUMBER
CTB125S2C
CTB125RA2C

All bases listed above are natural. UV Black mounting bases


are also available in nearly every size, insert 0 after the part
number.

For CUSTOMER SERVICE call 1-800-346-4175

173

BURNDY
Telecommunications Products
LIMITED WARRANTY
The full line of FCI BURNDY Products tools
is warranted to be free of defects in materials
and workmanship for a period of five (5) years
from the date of shipment. If inspection by an
FCI BURNDY products certified tool technician shows the trouble is caused by defective
workmanship or material, BURNDY will
repair, or at its option, replace the tool.

This Warranty does not apply


where:

Repairs or alterations have been made or


attempted by others.
Repairs are required because of normal
wear and tear.
The tool has been abused, misused or
improperly maintained.
The use of non-BURNDY products has
resulted in damage to the tool.

WARRANTY REPAIRS
Tools within the warranty period are repaired
at no cost to the owner, and receive a limited
warranty for the balance of the initial warranty period or one (1) year warranty whichever
is greater.

NON-WARRANTY REPAIRS
All non-warranty repaired tools are reconditioned at a maximum cost of 40% of a new
tool and receive a limited 1-year warranty. A
nominal service charge of $5.00 is applied to
all repairs to cover shop supplies, oil disposal
and other miscellaneous services not covered as part of the standard repair.

RETURN PROCEDURE
All tools sent to the BURNDY Tool Center or
an authorized repair center must be accompanied by a purchase order authorizing repair
and must include a detailed bill to and ship to
address. Requests for repair estimates before
work is done must be clearly stated on the
purchase order. All tools sent to the
BURNDY Tool Center or an authorized
repair center as a warranty claim must be
accompanied by a proof of purchase such as
an FCI invoice or invoice from any FCI distributor. All tools must be shipped at the
owner's expense, prepaid. BURNDY pays
for the return freight for all repaired tools,
same surface freight as received. Airfreight
returns will be returned in the same way, collect for non-warranty repair and prepaid for
warranty repairs.
This warranty and repair policy supercedes
all previous policies and is in effect January 1,
2005.

DISCLAIMER AND LIMITATION


OF LIABILITY
FCI'S SOLE OBLIGATION (AND BUYER'S
SOLE AND EXCLUSIVE REMEDY) FOR
ANY BREACH OF WARRANTY UNDER
THE FOREGOING WARRANTY SHALL BE
TO REPAIR (AT LOCATION DESIGNATED
BY FCI) OR, AT FCI'S OPTION TO
REPLACE FOB THE ORIGINAL POINT OF
DELIVERY ANY GOODS WHICH ARE
DEFECTIVE AND ARE SO SPECIFIED BY
BUYER IN A WRITTEN NOTICE TO FCI
WITHIN THE APPLICABLE WARRANTY
PERIOD. FCI EXPRESSLY DISCLAIMS
ANY AND ALL EXPRESS OR IMPLIED
WARRANTIES OTHER THAN THE WARRANTY OF ITS TITLE TO GOODS AND THE
WARRANTY HEREINABOVE SET FORTH.
SUCH DISCLAIMER INCLUDES, WITHOUT
LIMITATION, WARRANTY OF FITNESS
FOR A PARTICULAR PURPOSE AND
WARRANTY OF MERCHANTABLE QUALITY. LIMITATION OF LIABILITY FCI WILL
NOT, UNDER ANY CIRCUMSTANCES, BE
LIABLE FOR THE COST OF REMOVAL OR
REINSTALLATION OF GOODS OR THE
COST OF DISASSEMBLY OR REASSEMBLY OF EQUIPMENT IN CONNECTION
THEREWITH, OR FOR LOSS OF THE USE
OF BUYER'S EQUIPMENT OR FACILITIES,
OR FOR LOSS OF BUSINESS OR GOOD
WILL OR PROFITS, OR FOR COST OF
INSPECTION OR STORAGE, OR FOR ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE OR DESCRIPTION
WHATEVER WHICH MAY ARISE FROM
FCI'S SALE OF GOODS TO BUYER.

If the decision is made not to repair, a handling charge of $25.00 will be applied plus
return freight costs.

174

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE Y10D

SPECIFICATIONS
Length: 9-3/4
Weight: 13.5 oz.

HYTOOL
TWO TOOLS IN ONE
#22-10 AWG NYLON
INSULATED CONNECTORS
#22-10 AWG UNINSULATED
CONNECTORS

FOR USE ON
BOX CAT. TYPES

BULK CAT. TYPES

#10-22 AWG nylon insulated terminals


TN
TN-F
YAE-N BOX
YAE-N-F BOX
YAE-Z BOX
YAEV BOX

Hand-held plier type tool that will install #1022 AWG nylon insulated and uninsulated
terminals and splices, with a precision
machined wire cutter for aluminum and copper wire in the nose of the tool. Long handles
provide greater mechanical advantage.
5-year limited warranty.

YAES
YAES-E
YAE-N
YAE-N-F
YAE-Z
YAEV

#10-22 AWG nylon insulated splices


SN
SNM
YSE-H BOX *

YSE-HN *
YSES
YSE-H *

#10-22 AWG uninsulated (bare) terminals

BENEFITS

BENEFITS

Easy wire cutting with precision machined


cutting blade.
Save time, money and lower installed costs
with one tool for both nylon insulated and
uninsulated (bare) connectors.
Easy tool operation out of the carton.
No need to break in the tool prior to
actual usage.
A heavy duty forged steel tool, that has
a rust resistant finish will provide a long
durable life.

Easier crimping on #22-10 bare and nylon


insulated connectors because of the longer
handles that provides greater mechanical
advantage.*
Comfort grip handles fit hands comfortably
helping make the tool easy to use.
Terminals and splice connectors are UL
listed and CSA certified when installed
with the Y10D HYTOOL.
5-year limited warranty.

(CONTINUED)

T
T-F
YAV BOX
YAV-T-F BOX
YAV-H BOX
YAV-H-F BOX
YAV-Z BOX

YAD
YAD-F
YAV
YAV-T-F
YAV-H
YAV-H-F
YAV-Z

#10-22 AWG uninsulated (bare) splices


YSV BOX
YSV-H BOX

YSV
YSV-H

* Conductor crimp only.

Features

COMFORT
GRIP HANDLES

READY TO USE
LUBRICATED PIVOT

HEAVY DUTY
FORGED STEEL

PRECISION
MACHINED
WIRE CUTTER

LONG HANDLES
FOR GREATER
MECHANICAL
ADVANTAGE

For CUSTOMER SERVICE call 1-800-346-4175

RUST RESISTANT FINISH

#22-10
UNINSULATED
(BARE)

#22-10
NYLON
INSULATED

175

BURNDY
Telecommunications Products
TYPE Y10-22

SPECIFICATIONS
Length: 8-5/8
Weight: 11 oz.

HYTOOL
#22-10 AWG INSULATED
CONNECTORS
#22-10 AWG UNINSULATED
CONNECTORS

FOR USE ON
BOX CAT. TYPES BULK CAT. TYPES
#10-22 AWG NYLON INSULATED
TERMINALS
TN
YAES
TN-F
YAES-F
YAE-N BOX
YAE-N
YAE-N-F BOX
YAE-N-F
YAE-Z BOX
YAE-Z
YAEV BOX
YAEV

Hand-held plier type tool to install #10-22


AWG insulated and uninsulated terminals
and splices with a wire cutter in the nose of
the tool. Will strip #10-22 AWG wire and cut
common size mild steel and non-ferrous
screws. 5-year limited warranty.

#10-22 AWG NYLON INSULATED


SPLICES

BENEFITS
Easy wire cutting with anvil type wire
cutter design.
Crimps full range of insulated terminals
and splices #22-10 AWG.
Cut off dies for common size mild steel
and non-ferrous screws.
Crimps full range of uninsulated terminals
and splices #22-10 AWG.
Full range insulation strippers for wire
sizes #22-10. One step stripping.
Comfort grip handles fit hands comfortably
helping make the tool easy to use.
5-year limited warranty.
* Conductor crimp only.

SN
SNM
YSE-H BOX

YSE-HN *
YSES
*YSE-H *

#10-22 AWG VINYL INSULATED


TERMINALS
TP
TP-F
TP-ZBA-EZ

BA
BA-EF

#10-22 AWG VINYL INSULATED SPLICES


SP

BS

#10-22 AWG UNINSULATED


(BARE) TERMINALS
T
T-F
YAV BOX
YAV-T-F BOX
YAV-H-F BOX *
YAV-Z BOX

YAD
YAD-F
YAV
YAV-T-F
YAV-H-F *
YAV-Z

#10-22 AWG UNINSULATED


(BARE) SPLICES
YSV BOX
YSV-H BOX *

YSV
YSV-H *

Features
ONE STEP INDIVIDUALLY
SIZED WIRE STRIPPERS

COMFORT GRIP
PLASTIC HANDLES

176

#12-10 INSULATED
COLOR CODE YELLOW
SCREW AND
BOLT CUTTERS

#22-10
UNINSULATED

WIRE CUTTER

#22-14 INSULATED
COLOR CODE
RED & BLUE

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE Y8MRB-1

SPECIFICATIONS
Length: 9-1/2
Weight: 1.21 lbs.

HYTOOL
#22-8 AWG

FOR USE ON
BOX CAT. TYPES BULK CAT. TYPES

Hand-held full cycle ratchet tool for #8-22


AWG uninsulated terminals and splices. Full
cycle feature builds in reliability and removes
the human factor from the finished installation. 5-year limited warranty.

UNINSULATED TERMINALS
T
T-F
YAV BOX
YAV-L BOX
YAV-T-F BOX
YAV-Z BOX

YAD
YAD-F
YAV
YAV-L
YAV-T-F
YAV-Z

UNINSULATED SPLICES
YSV BOX
YSV-L BOX

YSV
YSV-L

BENEFITS

One tool to accommodate #22-8 AWG.


Lightweight.
Full cycle ratchet for positive crimping.
Inspection (PG) gauges available to check
each groove.

Groove
#18
#14
#10
# 8

Gauge#
PG395-1
PG396-1
PG397-1
PG398-1

Each indentor has its own identifying mark


for inspectability.
Jaw opening orientation, molded finger and
palm grips and the easy reach frame minimize user fatigue.

Features

FULL CYCLE
RATCHET
MECHANISM

NEST/INDENTORS
SIZE RANGE
#22-8 AWG

For CUSTOMER SERVICE call 1-800-346-4175

EMERGENCY
RELEASE

COMFORT GRIPS
STEEL
BODY

MOLDED FINGER GRIPS

177

BURNDY
Telecommunications Products
TYPES MR15, MR18,
MR20

FOR USE ON
MR15 Vinyl Insulated Terminals and
Splices (Wire Range 22-10 AWG)
Vinyl Terminals

HYTOOL

TP
TP-F
TP-Z
TP-LF

FULL CYCLE RATCHET


HAND TOOLS
The Types MR15, MR18 and MR20 series
HYTOOL incorporate a full cycle ratchet
mechanism that provides a complete, positive
crimp each time. Once started, the ratchet
mechanism does not allow the handles to be
opened until after the full ratcheting cycle is
completed, unless the user actuates the
emergency release lever. This provides for a
completed crimp before a connector can be
removed from the tool.

UL listed for use with BURNDY connectors.


Fully ratcheted tool to assure properly
crimped connections.
Easy groove indentification with color
coded dies.
Maximum crimping comfort grips.
Compact, narrow nose to work in confined
areas.
5-year limited warranty.

Vinyl Splices
SP

BS

MR18 Nylon Insulated Terminals and


Splices
Nylon Terminals
TN
TN-F
YAES
YAES-F

MR15
MR18
MR20

SN
SNM
YSE-HN
YSES

Terminals

Length:
Weight:
Open:
Closed
Wire Range:

Nylon Splices

MR20 Uninsulated Terminals and Splices


T
T-F
YAV
YAD
YAV-T-F

SPECIFICATIONS
BENEFITS

BA
BA-EF
BA-EZ
BA-EL

8.86
1.10 lbs.
5.90
2.50
#22-10 Awg.

YAD-F
YAV-H*
YAV-H-F*

Splices
YSV
YSV-H*

*Conductor crimps only.

MRTOOLKIT
Includes: MR Tool frame
MR18, MR15, and MR20 dies
and carrying case

Features

PERMANENT DIE SETS


HEAVY DUTY FORGED
STEEL FRAME

FULL CYCLE
RATCHET MECHANISM
EMERGENCY RELEASE

COMFORT GRIP HANDLES

178

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE Y1MRTC
HYTOOL

SPECIFICATIONS
Length:
Height:
Width:
Weight:
Wire Range:

#8 #1 COPPER HYDENT
TERMINALS, SPLICES, AND
#6#6 THIN-WALL C-TAPS
Type Y1MRTC mechanical full cycle ratchet
HYTOOL will accommodate copper compression HYDENT connectors for #8
through #1 code conductor and #8 through #2
Class I flexible strand copper conductor. The
Y1MRTC version adds the ability to crimp #2
solid copper and #3 strand copper conductors. The color coded die wheel rotates to
provide a proper match of the die and color
coded connector. The die index is embossed
on the crimped connector for permanent
inspectability. A ratchet mechanism assures
the tool must complete a full cycle before
releasing.

BENEFITS

Y1MRTC

Rotating die is color coded to match color


coded connectors
Die index embossment allows permanent
inspectability of installed connectors to
insure consistently reliable and dependable
connections.
Molded comfort grips reduce fatigue during
continuous use.
Ratchet mechanism assures a complete
crimp every time.
Emergency release mechanism allows tool
to be removed from connector in case of
mistaken die choice or to reposition tool.
5-year limited warranty.

Wire Range: #8-#1 AWG Class B,


#8-#2 Class I Flex.
#2 Solid & #3 Stranded

Cu Lug and Splice Connectors

Copper
Wire Size
# 8 AWG
Code & Flex
#6 AWG
Code
#6 AWG
Code & Flex
#4 AWG
Code
#4 AWG
Code & Flex
#3 AWG
#2 Sol.
#2 AWG
Code
#2 AWG
Code & Flex
#1 AWG
Code

Connector
Catalog
Types
YA8CYS8CYAV8CYSV8CYA6CYS6CYAV6CYSV6CYA4CYS4CYAV4CYSV4CYA3CYS3CYA2CYS2CYAV2CYSV2CYA1CYS1C-

9.875
2.72 (closed)
.73
1.7 lbs.
#8-#1 code conductor,
#8-#2 Class I Flex,
Up to #6-#6 (Brown)
type YC-L C-TAP

Die
Index #
Color

# of Crimps
Per Barrel
Length
Std
Long

49
Red

7
Blue

8
Grey

9*
White

10**
Brown

11**
Green

Y1MRTCKIT
Kit Contains:
Y1MRTC Full-cycle Ratchet Tool
Sturdy Metal Carrying Case
Terminals:
YA8CL2TC14, YA8CL2TC38,
YA6C2TC38, YA6CL2TC14,
YA6CL2TC14E1, YA6CL2TC14E2,
YA6CL2TC38, YAV6CL2TC14E2FX,
YAV6CL2TC14FX, YA4CL2TC14,
YA4CL2TC38, YA3C2TC38,
YA2C2TC28, YA2CL2TC38
Thin-Wall C-Taps:
YC4L12

* White die groove only available with Y1MR-TC model.


** Die Index 10 (Brown Die) and 11 (Green Die) use the same
die wheel crimp groove.
Die Index Number embossment on connector after crimp for
inspection verification.

For CUSTOMER SERVICE call 1-800-346-4175

179

BURNDY
Telecommunications Products
TYPE MD7-34R
POSI-PRESS
HYTOOL

SPECIFICATIONS
Crimp force:
Length:
Width:
Jaw Covering:

9,000 lbs.
26
8 at handles 4-1/2 at jaws
EPDM Rubber
(MD7-34RC).
Handle Material : Reinforced composite
polymer
Warranty: 5 years

HAND-OPERATED FULL
CYCLE RATCHET TOOL
The MD7-34R POSI-PRESS HYTOOL has
a full stroke ratchet that assures the user has
cycled the tool completely for a consistent
crimp every time. The tool handles are manufactured from a new reinforced composite
polymer that requires no adjustment for the
life of the tool. This new tool design assures
users that all connections installed with the
MD7-34R are consistent and reliable over the
life of the tool. A visual wear indicator
provides easy verification of the tool's condition. An emergency ratchet release allows
tool removal in case of mistaken die choice or
to reposition tool. The MD7-34R crimps color
coded lugs and splices for #8-500 kcmil class
B code conductor and #8-350 kcmil Cu Flex
conductor. It will also crimp thin wall C-Taps
from #12 - 3/0 AWG class B code conductor.
The color coded W-VT dies snap into the jaw
grooves easily with only one hand and lock
securely into the tool with the spring loaded,
positive lock, die retainer buttons. The die
index number is engraved in the crimping
groove to emboss the finished connection.
This makes inspection and verification of
proper installation an easy process. Due to
the one piece handle design, if the tool ever
wears beyond its useful life, it can be returned
to BURNDY's Tool Repair Center for refitting
at a fraction of the price of a new tool. A rubber covered version, the MD7-34R-C,
is available.

MD7-34 Tool Variations


MD7-34R - #8-500 Cu HYDENT, Full
Stroke Ratchet
MD7-34R-KIT 1 - MD7-34R, metal carrying
case and all dies for #8-500 kcmil Cu
HYDENT and C-Taps
MD7-34 - Supplied without the ratchet
mechanism
MD7-34-KIT1 - MD7-34, metal carrying
case, and all dies for #8-500 kcmil Cu
HYDENT and C-Taps for #12 - 3/0 AWG.

FEATURES
Full Stroke Ratchet Mechanism.
Ergonomically designed, one piece,
composite polymer handles.
Comfort grip handles.
Time-proven forged steel jaw designs.
No tool adjustment required.
Positive lock, spring loaded die retainer
buttons.
PTFE impregnated steel/bronze bushings
and stainless steel pins.
Color Coded Dies.
Die Index embossed on finished
connection.

FULL STROKE
RATCHET
MECHANISM
EMERGENCY
RATCHET RELEASE

BLANK INSERT PROVIDED FOR


PERSONALIZING TOOL FOR IDENTIFICATION
AND INVENTORY PURPOSES

REINFORCED POLYMER COMPOSITE HANDLES RATED


FOR 100 KV PER FOOT FOR FIVE MINUTES WHEN NEW
AND WHEN PROPERLY CLEANED

180

Copper Lugs and Splices #8-500 kcmil.


Types YA, YA-L, YA-L-TC, YA-L-NT,
YS-L, YS, YST, YA-TC
Copper Lugs and Splices #8-350 kcmil
Flex. Types YAV-L-TC-FX, YA-LB,
YA-TC-FXB, YSV-L, YAV-L-NT-FX,
YAV-L-FX, YAV-FXB
Copper Battery Lugs #8-350 kcmil Flex.
Types YAG-TC-LD
Thin wall C-taps #12 - 3/0 AWG.
Types YC-L

BENEFITS

Features
COMFORT GRIP DESIGN WITH CHECKERED
SURFACE AND ERGONOMIC HANDLE ENDS
PROVIDE A POSITIVE, SLIP-FREE GRIP

FOR USE ON

SPRING LOADED
POSITIVE LOCK
DIE RETAINER
BUTTONS

JAWS BUTT AT
COMPLETED
CRIMP

Easier tool operation due to unique handle


design, and anti-slip grips.
Grips and handle knobs improve operation
by preventing slipping.
Butting jaws assure proper crimps.
Wear indicator allows instant inspection
of calibration.
Full cycle ratchet assures complete
consistent crimp.
High grade hardware increases tool life
and durability.
Allows use of complete line of BURNDY
W-VT, W-RT and X-RT series dies.
Color coded dies simplify selection of
correct connector and die combinations.
Die Index embossment on crimp provides
easy inspection and quality assurance.
99,000 crimps without needing adjustment.
5-year limited warranty.

HIGH STRENGTH
STAINLESS STEEL PINS
RESIST CORROSION
AND HELP PROVIDE
LONG TOOL LIFE

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE MD6/MD7
TOOLING ACCESSORIES
Dies for Special Applications
(See present installation tool index in reference section for complete W-Die listing.)

Cat. No. PT4946


Compact Steel Die Case
Compact die case for (12) "W"
or "X" die sets. Dies purchased separately.

W-BG
The W-BG die is a double groove die set
requiring only one (1) crimp per end on
service entrance sleeves and only 1/2 the
number of crimps on other 5/8 sleeves.
W-28K
The W-28K cutter die permits use of
MD6/MD7 type tools as a cable cutter.
Conductor range: 4-4/0 ACSR, Aluminum
or Copper.

Non-Bowing Dies
Cat. Nos. W-687 and W-702
The Non-Bowing die sets install one-piece,
full-tension UNISPLICE sleeves on ACSR
conductors without bowing.
UNISPLICE ONE-PIECE SLEEVES:

Protective Jaw Covers

W-687 Installs: #4 ACSR 6/1, 7/1-YDS4RL


and YDS4RLY
#2 ACSR 6/1-YDS2RL
and YDS2RLY
W-702 Installs: #2 ACSR 7/1-YDSO21RL
and YDS021RLY
1/0 ACSR-YDS25RL
and YDS25RLY

Cat. No. MD6-CP1


The laminated vinyl covers, a non-conductive
material, are provided for the MD6/MD7
HYTOOL to avoid damage. Compact in
size, the covers snap easily into place over
the jaw edges without obstructing vision.
The MD6-CP1 fits all MD6/MD7 tool variations except the Snub-Nose MD6-6/MD7-6
type design. Supplied as a set.

PT4931-1
Die Button Repair Kit

Cat. No. PT6744


The semi-rigid Neoprene cover, a nonconductive material, is provided for the MD6-6
Snub-Nose HYTOOL to avoid damage.
Fits all MD6-6 Snub-Nose variations.

Cat. No. PT4925


Canvas Bag
The PT4925 is a sturdy canvas bag for protecting the MD6/MD7 tools with or without
rubber covers plus up to (9) die sets. Dies
purchased separately.

For CUSTOMER SERVICE call 1-800-346-4175

Cat. No. WDIETREE


W Die Holder
This innovative W-Die Holder replaces the
standard metal carrying case designed for
BURNDY W-Dies. Its straight forward design
allows for easy insertion of the W-Dies onto
the holder, providing greater flexibility and
secure storage.

Cat. No. PT4952-1


Steel Carrying Case
The PT4952-1 steel carrying case provides
storage and protection for the MD6 tools with
or without rubber covers plus up to (18) die
sets. Tool and die sets not included. Fits MD6,
MD6-6, MD6-8, MD6-14, MD6-37 , MD6-38,
MD7 and MD7-6.

Cat. No. PT6733


Hot-Line Tool Carrying Bag
The PT6733 is a heavy-duty, adjustable canvas bag for the storage and protection of HotLine Tools. The bag accommodates 48, 60
and 72 variations of the MD6 and Y35 HotLine Tools.

181

BURNDY
Telecommunications Products
TYPE MD6R

SPECIFICATIONS
Output force:
Handle input force:
Number of strokes:
Weight:
Length :

HYTOOL
FULL-CYCLE RATCHET TOOL
Installs full range of connectors (Taps,
Splices, Terminals): #6 through 4/0 AWG.

FOR USE ON

Applications: Overhead and underground


full-tension and non-tension. Use MD6-6R2
for code cable terminals and splices through
500 kcmil copper.
The MD6R full-cycle ratchet tool installs all
the same connectors using the same Wtype dies as the MD6 tool, plus the addition of
code cable connectors through 500 kcmil
copper.
A maximum handle force of 40 lbs. plus short
handle opening and angled head combine to
provide an ideal tool for difficult overhead
and tight underground applications. Fiveyear limited warranty.

12,000 lbs.
40 lbs.
5
10 lbs.
24

BENEFITS
Precise crimping everytime is provided
with the ratchet mechanism and automatic
release only after five (5) handle strokes.
Easy tool operation is provided with
40 lbs. maximum handle force reducing
possible back strain.
Convenient operator usage for difficult to
reach overhead and tight underground
trench applications is provided with the
angled head, short handle stroke and
minimal handle force requirements.
Easy handling and insertion is provided
with spring loaded handles.
The D3 groove accommodates the
complete line of W die inserts.
5-year limited warranty

Copper, Aluminum, ACSR, Copperweld,


Alumoweld, Steel, 6201, 5005,
Compressed and compact conductors.
Copper Taps: #10 sol.- 2/0 str.
Aluminum, ACSR Taps: #14 sol.4/0 ACSR.
Stirrups: #6 ACSR- 4/0 ACSR.
Overhead Full Tension Deadends, Full
Tension Splices, Non Tension Splices,
and Terminals Conductor Range:
#10 str.-4/0 ACSR.
Code conductor connectors:
#6-500kcmil. Copper.

Features
12,000 LBS.
CRIMP
FORCE

STANDARD
MD6 JAW
VARATIONS
HEAVY
GAUGE ABS
PLASTIC
PROTECTS
RATCHET
MECHANISM

MD6R Variations:
Cat. No.
MD6R
MD6-6R
MD6-6R-2

MD6-8R

Permanent Die Grooves


BG (5/8) and D3
D3 Snub-Nose
D3 Modified for copper
color coded dies #8 through
500 kcmil.
O and D3

45 ANGLED
HEAD

FIVE (5)
STROKES
REQUIRED
FOR COMPLETED
CRIMP AND
AUTOMATIC
RELEASE

Accessories:
Cat. No. PT4925
The PT4925 is a heavy-duty canvas carrying
bag for the storage and protection of the
MD6...R tools. Pockets for dies are included.
Cat. No. PT17188
ABS Cover Kit
The PT17188 is the heavy-duty ABS plastic
cover kit including (3) piece ABS cover, label
and hardware.

40 LB. MAX
HANDLE
FORCE
REQUIRED

SPRING
LOADED
STRAIGHT
HICKORY
HANDLES

FULL CYCLE
RATCHET
MECHANISM

PLASTIC
COMFORT
GRIPS
60 HANDLE
OPENING

182

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE Y500CT-HS

SPECIFICATIONS
Output Force:
Tool Weight:
Total Strokes:
Height:
Length:

L'IL CRIMP
6 TON - HYDRAULIC
CRIMP TOOL
The BURNDY Y500CT-HS HYPRESS
connector installation tool provides 6 U.S.
Short tons of force in a compact and easy to
use, hand-held hydraulic tool. The Y500CTHS incorporates a specialized latch style
head with a generous working stroke for a
wide variety of crimping applications. The
specialized head allows interference-free closures on tap connectors up to the BURNDY
YHD-400 size. The head is fitted onto a lightweight tool body with handles that are
ergonomically designed to provide slip-free
grip and easier crimping. The tool features a
patented high speed ram advance mechanism that minimizes crimp cycle time along
with an ergonomic trigger drain mechanism
that allows the ram to return to the preset
position. The tool accommodates all
BURNDY X, W, and W-VT style dies
that seat in the permanent D3 crimping
groove. Installation applications include #6
AWG to 500 kcmil copper lugs and splices, #6
AWG to 4/0 AWG aluminum lugs and splices,
and up to 4/0 aluminum tap connections. The
permanent D3 groove and 180 degree rotatable head are standard on the Y500CT-HS.
Each Y500CT-HS HYPRESS tool uses
BURNDY dies and off-the-shelf connectors
that are available worldwide. Your Y500CT-HS
HYPRESS comes equipped with a durable
metal carry case to hold the tool and a
multitude of die sets.

6 tons (5.4 metric tons)


7.8 lbs. (3.5 kg)
7 (w/o connector)
6.0 (152 mm)
17.6 (447 mm)

FOR USE ON
Copper, Aluminum, ASCR, Steel,
Copperweld, Alumoweld, 6201, 5005,
Compressed, Compact, Stranded &
Solid conductors
Installs splices, taps, or terminals:
#8 - 500 kcmil Copper Str
#8 - 350 kcmil Flex
#8 - 4/0 AWG Aluminum

Features and Benefits


Light weight latch head design.
Provides enhanced clearance for tap
connectors.
180 head rotation.
Versatile tool head allowing user crimp
access into tight spaces.
Ergonomic handle design.
Easier operation, helping reduce fatigue.
Audible pressure "pop-off" valve.
Indicates properly completed crimp.
Permanent "D3" crimp groove accepts all
BURNDY W and X dies.
Standard die design with proven
performance.
Durable metal carrying case.
Provides superior protection and stores
all accessories.
High speed ram advance.
Provides faster crimps.
Handle trigger drain.
Convenient ram retraction.
5-year limited warranty.
Customer satisfaction and technical
support.

RANGE TAKING DIES


WDC4500:

#4-500 Cu STR.
#2-4/0 Cu FLEX
UL and CSA for use on YA and YS series.
Also for use on YAV and YSV series.
WDA8300: #8-300 Al
#6-400 Cu STR.
#2-4/0 Cu FLEX
UL and CSA for use on YA, YS, YA-A, and
YS-A series. Also for use on
YAV and YSV series.

Features
ERGONOMIC
HANDLE DESIGN
SPRING LOADED DIE RETAINING PINS

LATCH HEAD RELEASE


6.0
[152]

FUNCTIONAL
D3 DIE GROOVE

180 ROTATABLE HEAD


SPECIALIZED LATCH DESIGN
17.6
[447]

For CUSTOMER SERVICE call 1-800-346-4175

183

BURNDY
Telecommunications Products
TYPE Y35 AND
Y35-2 HYPRESS

SPECIFICATIONS
Force developed:
Operating pressure:
Weight (less case):
Overall length:
Head width:
Molded Covering:

HAND-OPERATED HYDRAULIC TOOL


The Y35 HYPRESS Tool incorporates a
C-shaped, rotatable head for overhead line
work and compression grounding applications. The hook style head with extensive ram
travel provides for easy tapping and splicing
of overhead lines as well as HYGROUND
compression grounding systems.

Y35-2
12 tons
10,000 psi
13-1/2 lbs.
24
6
Head, Body
and Handles

FOR USE ON
Copper
#8 str.-500 kcmil
Code Cables

The Y35-2 HYPRESS head, body and


handles are covered with 3/16 rubber for tool
impact protection.

Copper
#8 str.-500 kcmil and
up to 3/4 ground rod
Copper
#8 str.-750 kcmil
Code Cables
N30-N500
Navy Cables
Flexible and
Extra Flex

Order the hot-line handle assembly, U dies


and accessories separately. 5-year limited
warranty.

BENEFITS
Compact C shaped head allows easy
placement and removal from continuous
conductor lengths.
Easy to position tool for work with 180
head rotation.
Versatile and economical-tool works with
all commonly used copper, aluminum and
ACSR conductors from #6 str. to #556.5
26/7 stranding.
Body and handles covered with 3/16
molded rubber for tool impact protection.
Easy die change accomplished with push
button die locks.
Quality assurance is provided with automatic 10,000 PSI blow-off pressure release
valve for positive crimping.

Y35
12 tons
10,000 psi
13 lbs.
23-1/4
4-3/4
Body &
Handles

BENEFITS (CONTINUED)
Rapid ram advance reduces installation
time by eliminating need to pump handles
to advance ram to connector.
Saves installation time with trigger controlled return release which returns ram to
its preset starting point.
Long continuous usage is aided with
comfort grip handles.
Compression terminal and splice connectors are UL listed and CSA certified when
installed with recommended die set.
Five year limited warranty.

Aluminum
#8 str.-750 kcmil
Code Cables

ACSR

Terminals-grounding
YGH, YGHA, YGF
Splices-grounding
YGS, YGHS
Taps-grounding
YGHC-C, YGHP-C
YGHR-C
Terminals Uninsulated
YA, YA-2N, YA-L, YA-LB
YA-2LN
Terminals Insulated
YAEV-L Box, YAEV-L
YAEV-H, YAEV-RS,
YAEV-RH
Splices To Size
400 kcmil
YS, YS-T, YS-L
YS-LB, YSV-L Box
YSV-L, YSM
Terminals
YA-A
AYP, AYPO
Splices To Size
350 kcmil
YSA, YRB, YS-AT
See Burndy Overhead
Transmission and
Distribution Catalog
Module

Features
COMFORT GRIP HANDLES

TRIGGER
CONTROLLED
RAM RELEASE

SHORT
HANDLE
THROW

RUBBER
COVERED
HANDLES

180 HEAD
ROTATION

C SHAPED HEAD

HOLE FOR LIFTING


EYE

BUILT-IN AUTOMATIC
10,000 PSI BLOW-OFF
RAPID RAM
PRESSURE RELEASE
ADVANCE
VALVE
HANDLE
(Y35-2 HAS RUBBER COVERED HEAD)

184

RUBBER
BODY
COVERING

POSITIVE PUSH
BUTTON DIE LOCKS

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
Y35 SERIES
ACCESSORIES

Cat. No. PT29291


Die Case
Steel case designed for storage and protecton of U dies used with the Y35 and other
BURNDY tools. Holds 15 die sets. Length 9
1/2, width 6, height 1-1/2. Dies sold
separately.

PT 29279-2
Force Test Gauge
The PT 29279-2 Force Test Gauge is
designed to provide an accurate visual reading of the output force produced by the handhydraulic Y35, Y35-2, Y39 and Y750
HYPRESS tools. It is not recommended for
any remote powered HYPRESS heads
such as the Y35BH. The PT 29279-2 Force
Test Gauge is factory calibrated and inspected to very stringent tolerances providing the
customer accuracy and an excellent means
for quality assurance control. Supplied with
padded storage case.

Cat. No. HH5-RL48


Hot-Line Handle Assembly
The HH5-RL48 is a 48" long fiberglass
handle assembly that easily attaches to a
standard Y35 HYPRESS tool. Rotation of
the handles controls the rapid ram advance
and release mechanisms. The handles are
rated at 100KV per foot for five minutes. The
Catalog Number does not include the Y35.
For factory assembled unit order Catalog
Number Y35-16.

Y34A INDENTOR ADAPTOR:


To use Y34A indentors in a Y35, Y39,
or Y750 tool.
Cat. No. Y35P3
SEAL REPAIR KIT:
Cat. No. Y35/Y39 REP KIT A
Steel Carrying Case
Cat. No. PT2972 for Y35
Cat. No. PT29360 for Y35-2

BENEFITS
Easy to read
Provides means for quality assurance
control.
Blank (test) U dies are provided for
testing procedure.
Tool output force is applied to load cell
for visual read out of the resulting force
on the dial.
The blank (test) U set is included with
the Force Test Gauge.
An easy to read operating and maintenance manual is included.

Cat. No. PT6733


Hot-Line Tool (Heavy-Duty)
Carrying Bag
The PT6733 is a heavy-duty, adjustable
canvas bag for the storage and protection of
hot-line tools. The bag accommodates 48
through 72 variations of the Y35 and MD6
hot-line tools.

For CUSTOMER SERVICE call 1-800-346-4175

185

BURNDY
Telecommunications Products
TYPE Y39
HYPRESS

SPECIFICATIONS
Force developed:
Operating force:
Weight - less case:
Overall length:
Max. head width:
Die accommodation:

HYDRAULIC TOOL HAND-OPERATED


The versatile, lightweight Y39 weighs 12 lbs.,
and its small 3-1/8 wide head rotates 180
for convenience and flexibility. The tool provides 12 tons of crimping power, while its
built-in overload valve automatically releases
pressure when the crimp is completed.

FOR USE ON
COPPER
#6 AWG -750 Kcmil str.
Code Cable
N30 - N650 Navy Cable
Flexible and Extra Flexible
Terminals -Uninsulated
YA, YA-L, YA-LB, YGH, YGHA
Splices & Tees - Uninsulated
YS, YS-L, YS-LB, YS-T, YSP-T, YST

The Y39 is designed for easy die insertion


and removal without ball checks or set
screws. Its rapid ram advance and triggercontrolled release eliminate unnecessary
pumping after every crimp. 5-year limited
warranty.

BENEFITS

BENEFITS

Easy to work in small tight spaces with


only a 3-1/8 wide compression head
and short handle throw.
Easy to position tool for work with 180
head rotation.
Versatile and economical-tool works on
all commonly used copper and aluminum
conductors from #6 str. to 750 kcmil.
Body and handles covered with 3/16
rubber.
Easy to locate and hold dies in position
with the positive push button die locks
plus die changing is accomplished easily
without ball checks or set screws.
Easy to remove or lock into position die
holder with recessed spring latch plus
leather strap to prevent loss.

Quality assurance is provided with


automatic 10,000 psi blow off pressure
release valve for positive crimping.
Rapid ram advance elmininates requirement for pumping handles to advance
ram to connector.
Trigger release allows ram to return to
preset position.
Long continuous usage is aided with
comfort grip handles.
Compression terminal, tap and splice
connectors are UL listed and CSA certified
when installed with the Y39 tool and
recommended die set.
Five year limited warranty.

(CONTINUED)

COPPER- AN or AIR
#6 AWG-#4/0 str. Code Cable
AN6-AN #4/0 Aircraft Cable
Flexible and Extra Flexible
Terminals - Uninsulated
YAV-L Box, YAV-L, YAV-Rs Box, YAV-RS
Splices - Uninsulated
YSV-L Box, YSV-L
COPPER-INSULATED TERMINALS
#8 AWG - #2/0 str. Code Cable
AN8 - AN #2/0 Aircraft Cable
Flexible and Extra Flexible
Terminals-Insulated
YAEV- L Box, YAEV- L, YAEV- RS Box,
YAEV- RS, YAEV-RH
COPPER-TAPS
#12 AWG Solid-250 kcmil
Taps -YC-C, YGHC -C, YGHP -C, YGHR -C,
YH, YCHC -TC
ALUMINUM
#8 AWG-750 kcmil str.
Code Cable
Terminals-YA-A
Splices-YS-A, YS-AT, YRB

Features
LEATHER DIE
RUBBER
RETAINER
BODY
STRAP
180 HEAD COVER
ROTATION

12 tons
10,000 PSI
12 lbs.
23
3-1/8
U-dies

BUILT IN AUTOMATIC
10,000 PSI BLOW-OFF
PRESSURE RELEASE
VALVE

ALUMINUM
#6 str.-500 kcmil
Taps -YFD, YFN, YFO

RAPID RAM
ADVANCE
HANDLE

SHORT
HANDLE
STROKE
POSITIVE PUSH
BUTTON DIE LOCKS
RECESSED
DIE RETAINER
SPRING LATCH

186

RUBBER
COVERED
HANDLES

TRIGGER
CONTROLLED
RAM RELEASE

COMFORT
GRIP HANDLES

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES Y750HS AND
Y750-2HS RUBBER
COVERED HEAD

SPECIFICATIONS
Force developed:
Weight:
Length:
Height:
Width:
Jaw opening:

750 REVOLVER HYPRESS

12 tons
14.5 lbs. (5.4 kg)
23.5 (7162 mm)
2.75 (838 mm)
8.0 (2438 mm)
1.65 (42 mm)

HYDRAULIC HAND OPERATED


TOOL 12 TON CRIMP FORCE

FOR USE ON

CONDUCTOR RANGE:
#8-750 KCMIL CU/AL
AND #4-556.5 KCMIL ACSR

Tension Sleeves
Copper
Aluminum
ACSR

#8 sol.-500 kcmil
#8 sol.-587-2 kcmil
#4-556.5 kcmil

Taps
Copper
Aluminum

#14 sol.-500 kcmil


#8-500 kcmil

Aerial Cable
Copper

#6-500 kcmil

The BURNDY Y750HS Series HYPRESS


is a wide mouth (1.65) hand operated
hydraulic 12 ton crimping tool for use on
virtually all compression applications. The
C-shaped head rotates 355 relative to the
handle and is mated to a patented rapid
advance pump. The Y750HS provides easy
tapping, splicing, and terminating of overhead
lines, the full line of HYGROUND compression grounding connectors, NEC cable
connections, and N30-N650 Navy cable
connections.
The Y750HS accepts all BURNDY U dies
for use on conductor ranges of
#12-750 kcmil AL/CU and #4-556.5 kcmil
ACSR conductors.
The Y750-2HS HYPRESS has a rubbercovered head and handles for tool impact
protection.

BENEFITS
Covers a wide range of applications with
a lightweight, self-contained system and
provides easy tool removal from continuous conductors with its C-shaped head.
Easy tool positioning with its 355 head
rotation.
Patented rapid advance pump for faster
crimps.
Exposed positive die lock buttons for easy
die change out and die retention.
Handle trigger drain for convenient ram
retraction.
Quality assurance is provided with an audible Pop-Off pressure relief valve.
Comfort grip handles help ease operator
fatigue with continuous use.

Features

Terminals & Splices


Aluminum
#8-750 kcmil
Copper
#8-750 kcmil
ACSR
#4-556 kcmil
HYGROUND (Compression Ground)
Copper
#8-500 kcmil
(cable/ground rod)
Ground Rods
1/2 - 1 Diameter

ACCESSORIES:
Cat. No.
Y750HSCASE

Description
Plastic Carrying Case for
Y750HS and Y750-2HS

BENEFITS (Continued)
Long life expectancy from the company
that provided the industry with the first selfcontained hydraulic tool in 1934.
Rubber covered head and handles on
Y750-2HS for tool impact protection.
Supplied with high impact plastic carrying
case.
Five year limited warranty.

For CUSTOMER SERVICE call 1-800-346-4175

187

BURNDY
Telecommunications Products
TYPE PATRIOT
PAT750C-18V

SPECIFICATIONS
Crimp Force: 12 Tons
(10.9 metric tons)
Tool Weight: 16.5 lbs (7.5 kg)
Length: 15-1/2 (39.37 cm)
Width: 3-1/2 (8.89 cm)
Height: 13-7/8 (35.24 cm)
Operating Voltage: 18 V-DC
Recharge Time: < 45 mins.

BATTERY ACTUATED TOOL


Hydraulic Self-Contained
12 Ton
The BURNDY PATRIOT can be operated
with only one hand, making them the only
true, one-handed battery powered crimping
tools available in the world today.
The BURNDY PATRIOT PAT750C-18V
incorporates
the
latest
engineering
technology with patent pending pump, transmission and piston component designs. Our
self-contained hydraulic tool provides a consistent, reliable connection every time. The
PAT750C-18V features BURNDYs Y750 tool
head, capable of using all U style dies, and
incorporates a patent pending bearing and
alignment guide for use on HYGROUND
and other asymmetrical connectors. Features
reliable head rotation design for operation in
virtually any position.
Each PATRIOT uses standard BURNDY
dies and off-the-shelf connectors available
worldwide. Supplied with a durable high
impact formed carrying case to hold the tool,
battery charger, two batteries, tool retention
lanyard, and die compartment to hold U die
sets. (Dies sold separately.) All BURNDY
PATOOL 18V series tools are provided with
a 5-year limited warranty.

FOR USE ON

FEATURES
True, one-handed operation for advance,
retract, and hold.
12-ton output force.
State of the art crimping head design,
360 head rotation.
Audible pop-off and Green indicator
indicates properly completed crimps.
Ergonomically balanced tool design.
Durable High Impact Formed carrying
case.
PAT750C-18V with rubber covered head
is available.
Ni-MH battery eliminates voltage
depression (memory issues).
5-year limited warranty on tool.
1-year warranty on battery and charger.

Features
AUDIBLE POP-OFF WITH
GREEN INDICATOR

SAFETY LANYARD
CONNECTION

Tension Sleeves
Copper
Aluminum
ACSR

#8 sol.500 kcmil
#8 sol.587-2 kcmil
#4556.5 kcmil

Taps
Copper
Aluminum

#14 sol.500 kcmil


#8 sol.500 kcmil

Aerial Cable
Copper

#6500 kcmil

Terminals and Splices


Aluminum
#8750 kcmil
Copper
#8750 kcmil
ACSR
#4556 kcmil
HYGROUND (Compression Ground)
Copper
#8500 kcmil
(cable/ground rods)
Ground Rods
1/2 1 Diameter

ACCESSORIES
Battery:
Hi-capacity Ni-MH
(2200 mA-hr)
Cat# BAT18V
Charger:
120V-AC
12/24V-DC

Cat# BATCHGR-18V
Cat# BCT/PATDCCHGR

Lanyard:

Cat# PT208620

LARGE JAW OPENING


TO ACCOMMODATE
ASYMMETRICAL
CONNECTORS

BENEFITS
ROTATIONAL HEAD
FOR USE WITH U
STYLE DIES

12 TON OUTPUT FORCE

ERGONOMICALLY
BALANCED TOOL
DESIGN

Easier tool operation.


Versatile tool head positioning lets user
get into tight areas easier.
Allows use of standard BURNDY dies
already in use.
Less down-time due to high capacity,
high voltage 18 volt battery.
Assures proper crimps with both audible
and visual indicators, leaving no doubt for
the tool user.
Ergonomically balanced tool eases
operation and helps lessen fatigue.
Smoother, quieter, more efficient tool
operation.
Durable high impact formed case provides
superior protection and stores all
accessories.

NI-MH 18 VOLT BATTERY

188

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE PATRIOT
PAT600C-18V

SPECIFICATIONS
Crimp Force: 6 Tons (US)
(5.4 metric tons)
Tool Weight: 10.9 lbs (4.9 kg)
Length: 14.5 (36.8 cm)
Width: 3.5 (8.9 cm)
Height: 13.75 (34.9 cm)
Operating Voltage: 18 V-DC
Crimp Time: Approx. 3 seconds
Recharge Time: < 45 mins.

BATTERY ACTUATED TOOL


Hydraulic Self-Contained
6 Ton
The BURNDY PAT600C-18V battery powered crimping tool provides a powerful 6 tons
of crimping force and completes a crimp in
approximately 3 seconds. The PAT600C-18V
is compact, easy to use and incorporates the
latest in battery tool technology. The
PAT600C-18V tool incorporates a specialized
latch style head with enhanced working
stroke and clearance capabilities. The specialized head allows interference-free closure
on tap connections up to the BURNDY YHD400 size including 350 kcmil aluminum connectors. Die selection with this tool includes
all BURNDY W and W-VT style dies which
seat in the permanent D3 crimping groove.
Installation applications include #8 AWG to
600 kcmil copper lugs and splices, #8 AWG to
350 kcmil aluminum lugs and splices (YA-A
and YS-A), and up to 4/0 aluminum tap connections. The permanent D3 groove and 180
degree rotatable head are standard on the
PAT600C-18V.
Each PAT600C-18V tool uses BURNDY dies
and off-the-shelf connectors available worldwide. The PAT600C-18V comes equipped
with a high impact formed carrying case to
hold the tool, a battery charger and two batteries. The case houses up to 10 W dies
(dies purchased separately). The PAT60018V uses industry standard batteries and
chargers. The PAT600C-18V comes complete
with a 5-year limited warranty and one year
on batteries and charger.

FOR USE ON

Features and Benefits


Battery powered crimp technology.
Easy tool operation and portability.
Advance design high speed pump completes crimp in approximately 3 seconds.
Longer life, efficiency, and reliability.
Ergonomic design allows one hand operation for ram advance and ram retraction.
User always has one hand free to
manipulate connector and conductor.
Variable speed trigger.
Provides flexibility in speed of ram
advance.
Ram holds position when trigger is
released.
Provides ability to hold the connector
between dies and check for proper
alignment prior to crimping action.
Mechanical ram release.
Reliable ram release (no battery power
consumption).
Specialized latch head design.
Provides enhanced clearance on tap
connectors when compared with competitive designs.

SAFETY LANYARD
CONNECTION

180 HEAD ROTATION


FUNCTIONAL D3
DIE GROOVE

6 TON OUTPUT FORCE

SPRING LOADED DIE


RETAINING PINS

ERGONOMICALLY BALANCED
TOOL DESIGN

TRIGGER GUARD

Copper, Aluminum, ACSR, Steel,


Copperweld, Alumoweld, 6201, 5005,
Compressed, Compact, Stranded & Solid
Installs splices, taps, or terminations:
#8 - 600 kcmil Copper Str. (YA, YA-L,YS,
YS-L)
#8 - 350 kcmil Flex
#8 - 350 kcmil Aluminum (YA-A & YS-A)

ACCESSORIES
Lanyard:

Cat# PT208620

W Die Holder

Cat# WDIETREE

Battery:
Hi-capacity
(2200 mA-hr)

Cat# BAT18V

Battery with LED light:


(3000 mA-hr)
Cat# BAT18VLED
Charger:
120V-AC
12/24V-DC
240/250V-AC

Cat# PATCHGR18V
Cat# BCT/PATDCCHGR
Cat# PATCHGR250V

180 degree head rotation.


Versatile tool head positioning lets user
get into tight areas easier.
Uses 18 volt Ni-MH batteries.
Eliminates voltage depression or
memory.
Audible pressure pop-off valve.
Indicates properly completed crimp.
Permanent D3 crimp groove accepts all
W-Dies.
Uses standard die design with proven
performance.
PAT600C-18V with covered head is available.
Covered head for impact protection.
Durable high impact formed carrying case.
Provides tool protection and stores all
accessories.
5-year limited warranty on tool, 1 year on
batteries and charger.
Customer satisfaction and support.

NI-MH 18 VOLT
BATTERY

For CUSTOMER SERVICE call 1-800-346-4175

189

BURNDY
Telecommunications Products
TYPE PATRIOT
PATCUT129ACSR-18V

SPECIFICATIONS
Tool Weight:
Length:
Width:
Height:
Operating Voltage:
Recharge Time:

BATTERY ACTUATED TOOL


Hydraulic Self-Contained
Cutter
The BURNDY PATCUT129ACSR-18V battery powered cutting tool is compact, fast,
easy to use and incorporates the latest in battery tool technology. The ergonomic design
allows one hand operation so that the other is
free to manipulate the conductor in the proper cutting position. The PATCUT129ACSR18V incorporates a specialized latch style
cutting head that allows interference-free closure for mid-span cuts. The cutter head
rotates 180 degrees to allow users to get into
tight areas easier. The PATCUT129ACSR18V is capable of cutting up to 1.29 diameter
copper and aluminum cable, 1113 ACSR,
5/8 ground rod, 1/2 rebar, 5/8 diameter soft
steel bolts, up to 1/2 standard guy strand,
and up to 3/8 EHS guy strand.
The PATCUT129ACSR-18V operates on
industry standard 18-volt Ni/MH batteries that
eliminate voltage depression or "memory"
issues. The PATCUT129ACSR-18V comes
equipped with a high impact formed carrying
case to hold the tool, a tool retention lanyard,
a battery charger and two batteries. The PATCUT129ACSR-18V is provided with a 5-year
limited warranty (excluding blades), and 1year on batteries and charger.
Made in the USA.

190

11 lbs.
14.5
3.5
13.5
18 V-DC
< 45 mins.

FOR USE ON

Features and Benefits


Battery powered cutting technology.
Easy tool operation and portability.
Advance design high-speed pump completes tough cuts faster.
Longer life, efficiency, and reliability.
Specialized latch head design.
Interference free closure for mid-span
cuts.
Ergonomic design allows one hand operation.
User has one hand free to manipulate
material to be cut.
180 degree head rotation.
Versatile head positioning allows user to
get into tight areas easier.
Mechanical ram release.
Reliable ram release (no battery power
consumption).
Operates on 18 volt Ni-MH batteries.
Eliminates voltage depression or
memory issues.
Durable high impact formed carrying case.
Provides tool protection and stores all
accessories.
5-year limited warranty on tool (excluding
blades) and 1 year on batteries and
charger.
Customer satisfaction and support.

Copper Cable: up to 1.29


Aluminum Cable: up to 1.29
ACSR: up to 1113 ACSR
Ground Rod: up to 5/8
Rebar: up to 1/2
Soft Steel Bolts: up to 5/8
Standard Guy Strand: up to 1/2
EHS Guy Strand: up to 3/8

ACCESSORIES
Lanyard:

Cat# PT208620

Battery:
Hi-capacity
(2200 mA-hr)

Cat# BAT18V

Battery with LED light:


(3000 mA-hr)
Cat# BAT18VLED
Charger:
120V-AC
12/24V-DC
240/250V-AC

Cat# PATCHGR18V
Cat# BCT/PATDCCHGR
Cat# PATCHGR250V

Replacement Blades:
Cat# PT10037388
(Moving Blade)
Cat# PT10037384
(Fixed Blade)

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
PATRIOT
PATCUT245CUAL-18V

SPECIFICATIONS
Tool Weight: 14.5 lbs (5.4 kg)
With Battery
Length: 18 (45.7 cm)
Width: 3.75 (9.5 cm)
Height: 14.75 (37.5 cm)
Operating Voltage: 18 V-DC
Recharge Time: < 45 mins.

BATTERY ACTUATED TOOL


Hydraulic Self Contained
Cutter
The BURNDY PATCUT245CUAL-18V battery powered cutting tool is compact, fast,
easy to use and incorporates the latest in battery tool technology. The ergonomic design
allows one hand operation so that the other is
free to manipulate the conductor in the proper cutting position. The PATCUT245CUAL18V incorporates a specialized latch style
cutting head that allows interference-free closure for mid-span cuts. The cutter head
rotates 180 degrees to allow users to get into
tight areas easier. The PATCUT245CUAL18V is capable of cutting up to 2.45 diameter
copper and aluminum cable.
The PATCUT245CUAL-18V operates on
industry standard 18-volt Ni-MH batteries that
eliminate voltage depression or "memory"
issues. The PATCUT245CUAL-18V comes
equipped with a high impact formed carrying
case to hold the tool, a tool retention lanyard,
a battery charger and two batteries. The PATCUT245CUAL-18V is provided with a 5-year
limited warranty (excluding blades), and 1year on batteries and charger.

FOR USE ON
Copper and
Aluminum Cable:

FOR COPPER AND ALUMINUM CABLE


ONLY. DO NOT CUT STEEL, GROUND
ROD, REBAR, OR GUY WIRE.

Features and Benefits


Battery powered cutting technology.
Easy tool operation and portability.
Advance design high-speed pump completes tough cuts faster.
Longer life, efficiency, and reliability.
Specialized latch head design.
Interference free closure for mid-span
cuts.
Ergonomic design allows one hand operation.
User has one hand free to manipulate
material to be cut.
180-degree head rotation.
Versatile head positioning allows user to
get into tight areas easier.
Mechanical ram release.
Reliable ram release (no battery power
consumption).
Operates on 18-volt Ni-MH batteries.
Eliminates voltage depression or
"memory" issues.
Durable high impact formed carrying case.
Provides tool protection and stores all
accessories.
5-year limited warranty on tool (excluding
blades) and 1-year on batteries and
charger.
Customer satisfaction and support.

SAFETY LANYARD
ATTACHMENT

180 HEAD
ROTATION

Up to 2.45 O.D
(62.2 mm)

ACCESSORIES
Carrying Case:

Cat# PT10044980

Lanyard:

Cat# PT208620

Battery:
Hi-capacity
(2200 mA-hr)

Cat# BAT18V

Battery with LED light:


(3000 mA-hr)
Cat# BAT18VLED
Charger:
120V-AC
12/24V-DC
240/250V-AC

Cat# PATCHGR18V
Cat# BCT/PATDCCHGR
Cat# PATCHGR250V

Replacement Blades:
Cat# PT10038657
(Moving Blade)
Cat# PT10040663
(Fixed Blade)

SPECIALIZED LATCH
HEAD DESIGN
PRECISION
CUTTING BLADES

2.45 CUTTING
CAPACITY
ERGONOMICALLY BALANCED
TOOL DESIGN

TRIGGER GUARD

18 VOLT Ni-MH
BATTERY

For CUSTOMER SERVICE call 1-800-346-4175

191

BURNDY
Telecommunications Products
YCUT129ACSR

SPECIFICATIONS
Force Developed:
Tool Weight:
Length:
Width:
Height:

Hydraulic Hand Operated


Cutter
The BURNDY YCUT129ACSR incorporates
a specialized latch style cutting head that
allows interference-free closure for mid-span
cuts. The cutter head rotates 180 degrees to
allow users to get into tight areas easier. The
YCUT129ACSR weighs only 11.4 pounds,
yet delivers 7 tons of cutting force. The
YCUT129ACSR with its hardened steel
blades is capable of cutting up to 1.29 diameter bare or insulated copper and aluminum
cable, 1113 ACSR, 5/8" ground rod, 1/2
rebar and 5/8 diameter soft steel bolts 1/2
standard guy strand and up to 3/8 EHS guy
strand.
The YCUT129ACSR comes equipped with a
high impact formed carrying case to hold the
tool and accessories. The BURNDY
YCUT129ACSR is provided with a 5-year limited warranty (excluding blades).

SPECIALIZED
LATCH HEAD
DESIGN

FOR USE ON

Copper Cable: up to 1.29


Aluminum Cable: up to 1.29
ACSR: up to 1113 ACSR
Ground Rod: up to 5/8
Rebar: up to 5/8
Soft Steel Bolts: up to 5/8
Standard Guy Strand: up to 1/2
EHS Guy Strand: up to 3/8

ACCESSORIES
Carrying Case:

Features and Benefits


Patented rapid advance pump.
Faster cuts with less hand strokes.
Specialized latch head design.
Interference free closure on mid-span
cuts.
Handle trigger drain
For convenient blade retraction.
Hardened steel blades.
Ability to cut ACSR, ground rods, rebar
and guy wire.
Comfort grip handles.
Help ease fatigue with continuous use.
180-degree head rotation.
Versatile head positioning to get into tight
areas easier.
Durable high impact formed carrying case.
Provides tool protection and stores
accessories.
5-year limited warranty on tool (excluding
blades).
Customer satisfaction and support.

Cat# PT10024162

Replacement Blades:
Cat# PT10037388
(Moving Blade)
Cat# PT10037384
(Fixed Blade)

ERGONOMIC HANDLE DESIGN

PRECISION
CUTTING
BLADES

1.29 CUTTING
CAPACITY

7 U.S. short tons


11.4 lbs. (5.1 kg)
22.4 (56.9 cm)
2.5 (6.4 cm)
6.6 (16.8 cm)

HANDLE TRIGGER
DRAIN

COMFORT
GRIP HANDLES

PATENTED RAPID
ADVANCE PUMP
180 HEAD DESIGN

192

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE BCC1000CUAL
BATTERY ACTUATED
CABLE CUTTER
The BURNDY BCC1000CUAL is a 12-V-DC
battery actuated cable cutter capable of cutting up to 750 kcmil hard drawn copper cable,
and up to 1000 kcmil soft drawn copper and
up to 2 O.D. aluminum cable. DO NOT CUT
STEEL or ACSR. The BCC1000CUAL comes
with battery powered cutting tool, sealed nickel cadmium 12V battery, 120V AC charger,
carrying case, and wrist loop which provides
added security when making cuts overhead.
The BURNDY BCC1000CUAL is designed
to cut copper and aluminum cables in a limited amount of space. The BCC1000CUAL
makes fast reliable cuts without stress to the
user. Just squeeze the trigger and it will cut
through your toughest copper and aluminum
cables. The BCC1000CUAL has a three-way
switch (forward, reverse, and neutral) which
allows the user to make partial cuts, back off
cables, or make adjustments during cutting.
The battery charge time is approximately 1
hour for a fast charge (80%), 4 to 6 hours for
a quick charge, and 14 to 16 hours for a standard charge (100%). The 12V battery can be
recharged approximately 1,000 times.
The BCC1000CUAL (excluding cutting
blades) is warranted to be free of defects in
material and workmanship for a period of 90
days, except in the case of abuse or
modification.

FEATURES

Hook head design.


Three way switch.
Hardened steel blades.
Ergonomic design.
Wrist loop.

SPECIFICATIONS
Specifications
Cutting Tool:
Drive Unit:
Dimensions:
Weight:
Cutting Capacity:

BENEFITS
Simplifies conductor cutting and allows
working in tight spaces.
Allows backing off cable, partial cuts,
and adjusting during cutting.
Helps ensure consistent cuts and longer
blade life.
Prevents hand/wrist injury.
Withstands rugged use. Resists oil
and solvents.
Added security when cutting cables
overhead.

Description
12.0V DC Motor
4L  4.5W  14.5 H
6 lb
1000 kcmil soft drawn
copper, 750 kcmil hard
drawn copper and up to
2 O.D. aluminum

Battery:
Battery Type:
Voltage:
Rated Capacity:
Charge Time:

Sealed nickel cadmium


12.0V DC
1.2A/hr
Fast, approx. 1 hour
Quick, 4-6 hours
Standard, 14-16 hours
Dimensions: 2.75L  2.7W  4.75H
Weight: 1.4 lb

Battery Charger:
Input Voltage:
Input Frequency:
Input Current
Dimensions:
Weight:

120V AC
60 Hz
110/120V
5.7L  3W  2.8H
2.2 lb

FOR USE ON
Maximum conductors accommodated:
750 kcmil hard drawn copper
1000 kcmil soft drawn copper
1000 kcmil alumimum

ACCESSORIES
Catalog Number
BCCBAT12V
BCCCHGR
BCCCASE
RP50RP03
RP50RP02

For CUSTOMER SERVICE call 1-800-346-4175

Item Description
BCC1000CUAL Battery
BCC1000CUAL Charger
BCC1000CUAL
Carrying Case
BCC1000CUAL
Fixed Blade
BCC1000CUAL
Moving Blade

193

BURNDY
Telecommunications Products
TYPES Y700DC-1B
AND Y420DC-1B

SPECIFICATIONS
MOTOR
Type:
Power Source:
Max Output:
Max Draw:
PUMP
Operating PSI:

Y-DC SERIES BATTERY


POWERED HYDRAULIC PUMP
HYDRAULIC OUTPUT
PRESSURES OF:
10,000 PSI AND 6,000 PSI
The lightweight, portable, battery powered
hydraulic pump unit for use with almost all
BURNDY HYPRESS remote tool heads
and cutters. The pump will provide approximately 30 operations before requiring a
recharge of the batteries, which can be
recharged in under 15 minutes, utilizing the
rapid charger provided. The high capacity 12
VDC batteries and charging system will allow
1,000 charge/discharge cycles per battery
providing more than double the life of other
batteries. The pump is supplied with a dielectric grade 6 long hydraulic hose, 1 rapid battery charger, and 2 rechargeable batteries.
Also included is an air-bulb control switch that
allows remote operation of the pump, or users
may opt for the built-in switch to operate the
unit. Both the Y700DC-1B and the Y420DC1B provide consistent, reliable compression
connections due to the factory-set pop-off
pressure relief valve. The full automatic operation allows the operator to control functions
such as Advance, Hold, and Retract at
will, truly making the Y-DC Series a versatile,
go-anywhere pump unit.

FEATURES

Lightweight, easy to carry.


Two modes of operation.
Transparent reservoir.
Charged/Low battery indicator.
Rapid battery recharger
(less than 15 mins.).
Allows use of wide range of remote
tool heads and cutters.

PUSH BUTTON CONTROL SWITCH


BATTERY STATUS INDICATOR
ON/OFF CONTROL SWITCH

SINGLE OR DUAL
BATTERY OPERABLE

194

FOR USE ON
Battery
Pump

Psi

Tools and Cutters

Y700DC-1B 10,000

Y420DC-1B 6,000

AIR BULB CONTROL

Y34BH, Y35BH, Y35BH-4,


Y39BH, Y75OBH, Y75OBH-2,
Y644MBH, Y45, Y45-1, Y46,
Y46-C
Y35L, Y35L-1, Y45L

ACCESSORIES
Steel Carry Case: Cat# YDC-CASE
Holds pump (w/2 batteries), Charger,
6 Hose, and air-bulb control
Batteries: Cat# BAT12B
Charger: Cat# BATCHGR

BENEFITS

Features
CARRY STRAP

Low-0.98 Mpa
High -68.6 + 3.4 Mpa
Hydraulic Fluid: BURNDY ALFLUID
Control Type: Air-bulb or switch
COMPLETE UNIT
DIMENSIONS
Weight: 15-1/2 lbs. with fluid
and two batteries
Height: 11.5
Width: 8.25
Depth: 6.5

BENEFITS
Lightweight and easy to lift, carry, and
transport to/around job site.
Advance and hold feature permits final
inspection before completing crimp cycle.
Transparent reservoir allows viewing for
daily checking of fluid level.
Choice of operation method with either
mounted switch or remote air-bulb
control devices.

Electric (12V-DC)
12V-DC batteries (2)
280 watt
35 amp

(CONTINUED)

Unit allows operation with only 1 battery


while the other recharging the other.
Built-in device prevents operation when
batteries have insufficient power to complete crimping cycle.
Able to operate in remote locations without
electric power source.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE Y35BH
HYPRESS
10,000 PSI

SPECIFICATIONS
Operating pressure:
Jaw Opening:
Force developed:
Weight (less case):
Maximum width:
Maximum height:
Molded covering:

REMOTE POWER OPERATED


COMPRESSION TOOLS
The Y35BH...series remote head is designed
for remote power operation and incorporates
the same C-shaped head as the Y35. The
hook style head with extensive ram travel provides for easy tapping and splicing of overhead lines as well as HYGROUND compression grounding systems.
The remote power operated Y35 heads are
available covered with 3/16 molded rubber
cover for tool impact protection.
Order head, hose, pump, dies and accessories separately. Five-year limited warranty.

Y35BH
10,000 psi
.95
12 tons
8 lbs.
4-3/4
9-1/4

Y35BH-4
10,000 psi
.95
12 tons
9 lbs.
6
10-1/2
Yes

FOR USE ON
CONNECTOR
TYPE

CONDUCTOR
RANGE

Tension Sleeves Copper


#8 sol.-500 kcmil
Aluminum #6 sol.-636 kcmil
ACSR
#4 -556.5 (26/7)

BENEFITS
Easy tool removal from line conductor after
compression taps are installed with the
open C shaped head.
Easily lifted into working position using
the lifting eye.
Easy die changing plus secure die alignments provided with the positive die
lock buttons.
Long life expectancy is provided with
heavy duty reinforced back.
Mates with all universal type Hot-stick
tooling.
Rapid assembly and disassembly is
provided with the quick disconnect
hydraulic fitting.
Type Y35BH-4 head is covered with
3/16 molded rubber.
5-year limited warranty.

FEATURES
HEAVY-DUTY
REINFORCED BACK

C-SHAPE HEAD
LIFTING EYE

POSITIVE DIE
LOCK BUTTONS

Taps
Aerial Cable
Connectors

#14-556.5 ACSR (18/1)


Copper
#6 str.-500 kcmil
Aluminum #4 str.-600 kcmil

Code Conductors Copper

#8 str.-750 kcmil Term


(400 kcmil splice)
Aluminum #6 str.-750 kcmil Term
(400 kcmil splices)

HYGROUND
Compression
Grounding

Copper
(cable/cable)

#6-500 kcmil

Copper
#6-250 kcmil
(cable/grd. rod)
Ground Rods

1/23/4

Y35BH Variations:
Y35BH

Head Only.

Y35H

Includes the Y35BH HYPRESS


head, PT29402-1 universal
hot-stick adapter, and steel
carrying case.

Y35B

Includes the Y35BH HYPRESS


head, PT91 steel reinforced
hydraulic hose and an FP10
foot pump in a steel carrying
case. Note: NOT for use on
energized conductors.

Y35BH-4 Permanent Molded Rubber Head.


The Y35BH-4 is covered with
3/16 molded rubber for tool
impact protection (not insulation).

QUICK DISCONNECT
HYDRAULIC FITTING
LARGE JAW
OPENING

For CUSTOMER SERVICE call 1-800-346-4175

195

BURNDY
Telecommunications Products
TYPE Y750BH
HYPRESS
10,000 PSI

SPECIFICATIONS
Operating pressure:
Force developed:
Jaw opening:
Length:

12 TON REMOTE
POWER OPERATED
HYDRAULIC TOOL

All standard BURNDY Y35 series U dies fit


the Y750BH HYPRESS. Dies and accessories sold separately.
The Y750BH-2 has a permanently molded
rubber head and includes a separate rubber
molded boot that covers the lower body and
hydraulic fitting for tool impact protection.
Five-year limited warranty

Y750BH-2
10,000 psi
12 tons
1.65
18.93
(includes boot)

Weight: 10.3 lbs.


Head width: 4.43
Molded Covering:

CONDUCTOR RANGE:
#14-750 kcmil AL/CU
#4-556.5 kcmil ACSR
12 ton remote power operated hydraulic tool.
The Y750BH HYPRESS incorporates a
wide mouth (1.65") C-shaped head for all
compression applications. The hook style
head provides for easy tapping, splicing, and
terminating of overhead lines as well as the
full range of HYGROUND compression
grounding system connectors, NEC cable
connections and N30-N650 Navy cable applications.

Y750BH
10,000 psi
12 tons
1.65
12

11.8 lbs.
4.92
Yes

FOR USE ON
Tension Sleeves
Copper
#8 sol-500 kcmil
Aluminum
#6 sol.-587-2 kcmil
ACSR
#4-556.5 kcmil

BENEFITS
Covers a wide range of applications and
provides easy tool removal from continuous conductors with its C-shaped head
(1.65 opening).
Easy die change out and retention within
exposed positive die lock buttons.
Uses all standard BURNDY U-dies.
Y750BH-2 provides molded rubber covering on head, body and hose fittings.
Hot stick adapter sold separately.
Infinitely rotatable head, so hydraulic
couplers wont easily loosen.
5-year limited warranty.

Taps
Copper
Aluminum

#14 solid 500 kcmil


#6-500 kcmil

Aerial Cable
Copper

#6-500 kcmil

Terminals and Splices


Aluminum
#8-750 kcmil
Copper
#8-750 kcmil
ACSR
#4-556 kcmil
HYGROUND (Compression Ground)
Copper
#6-500 kcmil
(cable/grd. rod)
Ground Rods 1/2 1 Diameter

ACCESSORIES:
Cat. No.:
PT23484

Patented.

Description:
Hot stick adapter.

FEATURES
MODULAR
COMPONENT
DESIGN

LIFTING EYE HOLE

HOT STICK
ATTACHMENT
STANDARD ON
ALL VERSIONS

HEAVY DUTY HEAD ROTATES


360 SO HYDRAULIC COUPLERS
WONT LOOSEN

196

BOTH DIE
RELEASE
BUTTONS
EXPOSED

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE KOMPRESSOR
LPHY750

SPECIFICATIONS
LPHY750
Flow Rate: 3 - 9 GPM
(11 - 34 LPM)
Operating Pressure: 1,500 - 2,500 psi
(103 - 172 BAR)
Force Developed: 12 Tons
Weight: 21 lbs (9.5 kg)
Overall Length: 20.65 in (524 mm)
Width: 15 in (381 mm)
Jaw Opening: 1.65 in (42 mm)
Max. Back Pressure: 250 psi (17 BAR)
Crimp Time: Approximately
2 seconds

REMOTE OPERATED 12 TON


LOW PRESSURE HYDRAULIC
COMPRESSION TOOL
The BURNDY LPHY750 KOMPRESSOR
is a lightweight, compact, low pressure,
hydraulic 12 ton crimping tool. The LPHY750
is double acting for hydraulic ram advance
and retract. The KOMPRESSOR also has
an industry exclusive spring back up for ram
retraction in case of loss of hydraulic pressure. The LPHY750 comes equipped with an
ergonomic handle designed for better
balance, which helps lessen fatigue to the
operator.
The LPHY750 KOMPRESSOR features
the BURNDY Y750 tool head with a 1.65
jaw opening capable of using all industry
standard BURNDY U dies. The LPHY750
also has an industry exclusive visual crimp
indicator to assure the operator of a properly
completed crimp. The LPHY750 also has an
audible crimp indicator.
The LPHY750 is powered directly from open
center or closed center hydraulic tool circuits
present on most utility line trucks or can be
operated from individual low-pressure
hydraulic power units. The LPHY750 can be
switched from open center to closed center
operation with a simple external adjustment.
The LPHY750 does not require any additional
tooling such as boosters, intensifiers, or hand
controls in the bucket. Five-year limited
warranty.

BENEFITS

FOR USE ON

Visual and audible crimp indicator assures


properly completed crimps with 12 tons of
force.
Covers a wide range of applications with
its 1.65 jaw opening.
350 head rotation for versatile tool head
positioning allowing the user to get into
tight areas easier.
Uses all standard BURNDY U dies.
Operates on open center or closed center
hydraulic systems.
Ergonomic handle design for better
balance and helps lessen fatigue.
Double acting tool for hydraulic ram
advance and retraction.
Spring back up for ram retraction if
hydraulic system shuts down.
5-year limited warranty.

Tension Sleeves
Copper
Aluminum
ACSR

#8 sol - 500 kcmil


#8 sol - 587.2 kcmil
#4 - 556.5 kcmil

Taps
Copper
Aluminum

#14 sol - 500 kcmil


#8 sol - 500 kcmil

Aerial Cable
Copper

#6 - 500 kcmil

Terminals and Splices


Copper
#8 - 750 kcmil
Aluminum
#8 - 750 kcmil
ACSR
#4 - 556.5 kcmil
HYGROUND
Copper
Ground Rods

#8 - 500 kcmil
1/2 - 1 diameter

ACCESSORIES
Hoses:
Cat No. LPHTHOSNCR66668OP
Direct connect 8 non-conductive hose set

Activation Trigger
Ergonomically Balanced Tool
and Handle Design
Large 1.65 Jaw
Opening
Exposed Die
Release Buttons
for BURNDY
Style U dies

Visual Crimp
Indicator
Open Center,
Closed Center
Adjustment

Cat No. LPHTHOSNCR666610OP


Direct connect 10 non-conductive hose set
*Cat No. LPHTHOSNCR66668
8 non-conductive hose set
*Cat No. LPHTHOSNCR666610
10 non-conductive hose set
Hydraulic Fittings:
Cat No. LPHTHTMANOSE66
Male coupler 3/8 HTMA
Cat No. LPHTHTMABODY66
Female coupler 3/8 HTMA
Cat No. LPHTADPSMFOP66
Swivel Adapter

Y750 Tool Head


12 Tons of
Output Force

*These hoses are used with the


LPHTADPSMFOP66 swivel adapter.

Internal Ram Retraction


Backup Spring

For CUSTOMER SERVICE call 1-800-346-4175

197

BURNDY
Telecommunications Products
TYPE KOMPRESSOR
LPHY46

SPECIFICATIONS
LPHY46
Flow Rate: 3-9 GPM (11-34 LPM)
Operating Pressure: 1,550-2,500 psi
(107-172 BAR)
Force Developed: 15 Tons
Weight: 28.5 lbs (13 kg)
Overall Length: 18 in (465 mm)
Width: 6 in (153 mm)
Max. Back Pressure: 250 psi (17 BAR)
Crimp Time: Approximately
2 seconds

REMOTE OPERATED 15 TON


LOW PRESSURE HYDRAULIC
COMPRESSION TOOL
The BURNDY LPHY46 KOMPRESSOR is
a compact, low pressure, hydraulic 15 ton
crimping tool. The LPHY46 is double acting
for hydraulic ram advance and retract. The
KOMPRESSOR also has an industry
exclusive spring back up for ram retraction in
case of loss of hydraulic pressure. The
LPHY46 comes equipped with an ergonomic
handle designed for better balance, which
helps lessen fatigue to the operator.
The LPHY46 KOMPRESSOR features the
BURNDY Y46 tool head with a 2 jaw opening capable of using all industry standard
BURNDY P dies, and U dies, with
PUADP-1 adapter. The LPHY46 has a visual
and audible crimp indicator that assures
properly completed crimps with 15 tons of
force.
The LPHY46 is powered directly from open
center or closed center hydraulic tool circuits
present on most utility line trucks or can be
operated from individual low-pressure
hydraulic power units. The LPHY46 can be
switched from open center to closed center
operation with a simple external adjustment.
The LPHY46 does not require any additional
tooling such as boosters, intensifiers, or hand
controls in the bucket. Five-year limited
warranty.

Large 2 Jaw Opening

Y46 Tool Head

FOR USE ON
BENEFITS
Visual and audible crimp indicator assures
properly completed crimps with 15 tons of
force.
Covers a wide range of applications with
its 2 jaw opening.
350 head rotation for versatile tool head
positioning allowing the user to get into
tight areas easier.
Uses all standard BURNDY P dies, and
U dies with PUADP-1 adapter.
Operates on open center or closed center
hydraulic systems.
Ergonomic handle design for better
balance and helps lessen fatigue.
Double acting tool for hydraulic ram
advance and retraction.
Spring back up for ram retraction if
hydraulic system shuts down.
5-year limited warranty.

CONNECTOR
TYPE

CONDUCTOR
RANGE

Copper
#8-AWG str. 1500 kcmil
Code Cable
Navy Cables
Flexible and
Extra Flexible
1/2-1 Ground
Rods

Terminals-grounding to 500 kcmil


YGA, YGHA, YGF
Terminals-Uninsulated #8 to
1500 kcmil YA, YA-2N, YA-L
YA-LB, YA-TC, YA-2LN, YAB-4N

Aluminum
#8 AWG1250 kcmil
Code Cables

ACSR

YAV-L Box, YAV-L,


YAV-RS Box, YAV-RS,
YA-TC-FX
Terminals-Insulated #8 to 2/0
YAEV-L Box, YAEV-L,
YAEV-H, YAEV-RS, YAEV-RH
Splices #8 to 1500 kcmil
YS, YS-T, YS-L, YS-LB, YST,
YSP-T, YGS, YGHS
Taps
YH, YCHC #14 to 1000 kcmil
YC-C to 4/0 AWG
Taps-Grounding to 500 kcmil
YGHC-C, YGHP-C, YGHR-C
Terminals
YA-A, AYP, AYPO
Splices
YS-A, YS-AT, YRB
Taps
YFD, YFN, YFO, YFR
See Burndy Overhead
Transmission and Distribution
Catalog Module

Variable Speed Trigger


Ergonomically Balanced Tool
and Handle Design
Visual Crimp
Indicator

ACCESSORIES
Cat No. PUADP-1
U - Die adapter
Cat No. P15K
Cutter die (max. 1.2 dia.)
Hoses:

Open Center,
Closed Center
Adjustment

Exposed Die
Release Buttons
for BURNDY
Style P Dies or
U Dies with
Adapter
Lifting Eyes

Cat No. LPHTHOSNCR66668OP


Direct connect 8 non-conductive hose set
Cat No. LPHTHOSNCR666610OP
Direct connect 10 non-conductive hose set
*Cat No. LPHTHOSNCR66668
8 non-conductive hose set
*Cat No. LPHTHOSNCR666610
10 non-conductive hose set
Hydraulic Fittings:
Cat No. LPHTHTMANOSE66
Male coupler 3/8 HTMA

350 Head Rotation

Cat No. LPHTHTMABODY66


Female coupler 3/8 HTMA

15 Tons of Output Force

Cat No. LPHTADPSMFOP66


Swivel Adapter
*These hoses are used with the
LPHTADPSMFOP66 swivel adapter.

198

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE Y46 AND Y46C
HYPRESS
10,000 PSI

SPECIFICATIONS
Force developed:
Operating pressure:
Jaw opening:
Maximum width:
Overall length:

15 TON FORCE REMOTE OPERATED


HYDRAULIC TOOL

Y46
15 Tons
10,000 psi
2
4-1/2
15

Weight (less case): 16 lbs.


Molded Covering: No

The Y46 standard tool and Y46C rubber covered tools are lightweight, compact and
versatile with installation dies for both circumferential and nest-indentor types. Accessories
include U- die adapter, a cable cutting die
for 1.2 diameter non-steel conductors, plus a
lifting eye and universal hot-stick adapter for
overhead line construction. 5-year limited
warranty.

Y46C
15 Tons
10,000 psi
2
4-3/4
21-3/4
(incl. boot)
17-1/2 lbs.
Yes

FOR USE ON
CONNECTOR
TYPE

BENEFITS
Compact C shaped head allows easy
placement and removal from continuous
conductor lengths.
Versatile and economical-HYPRESS
tools work on all commonly used copper
and aluminum products.
Dies and adapters lock into or remove from
tool head easily with the positive push button die locks.
Safety, strength and high quality is provided with strong forged steel and precision
machined components.
Excellent for HYGROUND compression
grounding applications through 1" ground
rods and up to 500 kcmil taps, terminals
and splices.
Compression terminal, splice and tap connectors are UL listed and CSA certified
when installed with the Y46 and Y46C
HYPRESS and recommended die set.
Y46C has a permanently molded head
of 3/16" rubber and includes a separate
molded rubber boot to cover the lower
HYPRESS body and hydraulic coupler
for impact protection.

Copper
#8 AWG str.1500 kcmil
Code Cable
Navy Cables
Flexible and
Extra Flexible
1/2"-1" Ground Rods

CONDUCTOR
RANGE
Terminals-grounding to 500 kcmil
YGA, YGHA, YGF
Terminals-Uninsulated #8 to
1500 kcmil YA, YA-2N, YA-L,
YA-LB, YA-TC, YA-2LN, YAB-4N,
YAV-L Box, YAV-L, YAV-RS Box,
YAV-RS, YA-TC-FX
Terminals-Insulated #8 to 2/0
YAEV-L Box, YAEV-L, YAEV-H,
YAEV-RS, YAEV-RH
Splices #8 to 1500 kcmil
YS, YS-T, YS-L, YS-LB, YST,
YSP-T, YGS, YGHS
Taps
YH, YCHC #14 to 1000 kcmil
YC-C to 4/0 AWG
Taps-Grounding to 500 kcmil
YGHC-C, YGHP-C, YGHR-C

Aluminum
#8 AWG1250 kcmil
Code Cables

Terminals
YA-A, AYP, AYPO
Splices
YS-A, YS-AT, YRB
Taps
YFD, YFN, YFO, YFR

ACSR

See Burndy Overhead


Transmission and
Distribution Catalog Module

ACCESSORIES:
Cat. No.
P15K
PUADP-1
PT10121
PT10128
PT10131

FEATURES
POSITIVE
PUSH
BUTTON
DIE LOCK

LARGE 2
JAW
OPENING

Y46-2

FORGED
STEEL
BODY

Cutter die max. 1.2 dia.


U-die adapter
Lifting eye
Universal hotstick adapter-Y46
Universal hotstick adapter-Y46C
Same as Y46 with Female
coupler

MALE QUICK
DISCONNECT
10,000 PSI
HYDRAULIC FITTING
STRONG
REINFORCED
BACK

PRECISION
MACHINED STEEL
COMPONENTS

For CUSTOMER SERVICE call 1-800-346-4175

199

BURNDY
Telecommunications Products
TYPE RHCC129ACSR

SPECIFICATIONS
Operating Pressure:
Tool Weight:
Length:
Width:

10,000 PSI Remote Cable


Cutter
REMOTE POWER OPERATED
HYDRAULIC CABLE CUTTER
The BURNDY RHCC129ACSR remote
hydraulic cable cutter incorporates a specialized latch style cutting head that allows interference-free closure for mid-span cuts. The
RHCC129ACSR with its precision cutting
blades is capable of cutting up to 1.29 diameter bare or insulated copper and aluminum
cable, 1113 ACSR, 5/8 ground rod, 1/2
rebar, 5/8 diameter soft steel bolts, 1/2 standard guy strand, and up to 3/8 EHS guy
strand.
The RHCC129ACSR is provided with a
5-year limited warranty (excluding blades).

10,000 psi (700 bar)


5.85 lbs. (2.65 kg)
11.25 (286 mm)
3.7 (94 mm)

FOR USE ON

Copper Cable: up to 1.29


Aluminum Cable: up to 1.29
ACSR: up to 1113 ACSR
Ground Rod: up to 5/8
Rebar: up to 1/2
Soft Steel Bolts: up to 5/8
Standard Guy Strand: up to 1/2
EHS Guy Strand: up to 3/8

ACCESSORIES
Features and Benefits
Specialized latch head design.
Interference free closure for mid-span
cuts.
Precision cutting blades.
For clean cuts on Cu/Al, ACSR, ground
rods, rebar, guy strand, and soft steel
bolts.
High strength steel cylinder.
For durability and long life.
Lightweight ergonomic design allows one
hand operation.
User has one hand free to manipulate
material to be cut.
Durable canvas carrying bag.
Provides tool protection and stores all
accessories.
5-year limited warranty on tool (excluding
blades).
Customer satisfaction and support.

Canvas Bag:

Cat# PT10043890

Replacement Blades:

Cat# PT10037388
(Moving Blade)
Cat# PT10037384
(Fixed Blade)

PRECISION CUTTING BLADES


HIGH STRENGTH
STEEL CYLINDER

QUICK DISCONNECT
HYDRAULIC FITTING

SPECIALIZED LATCH
HEAD DESIGN
1.29 CUTTING
CAPACITY

200

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPE MCC500
AND MCC1000

SPECIFICATIONS
Catalog
Number

MANUAL CABLE CUTTERS

Overall
Length

Capacity Max.
Copper and Insulation
Aluminum Diameter Weight

MCC500 21
500 kcmil
(533 mm)

The MCC500 and MCC1000 manual cable


cutters are precision high quality tools
designed to cut up to 500 kcmil and 1000 kcmil
copper and aluminum cables respectively.
Rugged steel blades and fiberglass handle
construction provide cutting ease, minimum
cable distortion and long life. The MCC500 and
MCC1000 cable cutters are warranted to be
free of defects in material (excluding blades)
and workmanship for five years except in the
case of abuse or modification.

1.25
(32 mm)

3.5 lbs
(1.5 kg)

MCC1000 32
1000 kcmil 1.90
(813 mm)
(48 mm)

9.0 lbs
(4.0 kg)

FOR USE ON

MCC500

Maximum conductors accommodated:


MCC500:
500 kcmil Copper and Aluminum

MCC1000

MCC1000:
1000 kcmil Copper and Aluminum

FEATURES
High quality design and construction.
Rugged high quality steel blades.
Fiberglass handles with soft grips.

BENEFITS
Easy cutting with minimum cable distortion
and long life.
Excellent cutting edge performance.
Provides comfortable tool operation and
long life.

HANDLES
REPLACEMENT
BLADES

HANDLE GRIPS

For CUSTOMER SERVICE call 1-800-346-4175

201

BURNDY
Telecommunications Products
TYPE RCC556
AND RCC1000

FEATURES
Patented, high strength steel blades.
Bi-directional ratchet mechanism.
Thumb-controlled rapid blade movement
feature (fast action mode).
Fiberglass handles with soft grips.
Stiffener bar (RCC556 only).

RATCHET CABLE CUTTERS


The RCC556 and RCC1000 ratchet cable
cutters are precision high quality tools
designed to cut up to 556 ACSR and 1000
kcmil copper and aluminum cables respectively. The tools are equipped with rugged
steel blades, a precision bi-directional ratchet
mechanism for positive blade control, a fast
action thumb slide collar for fast blade movement (when not cutting) and rugged fiberglass handles. The RCC556 and RCC1000
ratchet cable cutters are warranted to be free
of defects in material (excluding blades) and
workmanship for five years except in the case
of abuse or modification.

BENEFITS
Provides ease of cutting and long life.
Provides positive control of blade
movement and greater cutting capacity.
Provides convenient quick closing or
opening of blades when cutting is not
being done.
Provides comfortable tool operation
and long life.
Increases operator safety when cutting
ACSR cable.

RCC556

RCC1000

FOR USE ON

SPECIFICATIONS

Maximum conductors accommodated:

Catalog
Number

Overall
Length

Capacity: ACSR,
Copper and Aluminum

Max. Insulation
Diameter

RCC556

21
(533 mm)

556 ACSR
600 kcmil Al/Cu
(32 mm)

1.25
(1.5 kg)

3.5 lbs

32
(813 mm)

1000 kcmil AL/Cu


(48 mm)

1.90
(4.0 kg)

9.0 lbs

RCC1000

MOVABLE
JAWS

STATIONARY
JAW

Weight

RCC556:

556 ACSR
600 kcmil Copper
and Aluminum

RCC1000:

1000 kcmil Copper


and Aluminum
Do not cut steel or ACSR

DIRECTION
OPEN/CLOSE

COVER

HANDLE GRIPS

RAPID ADVANCE
FEATURE

202

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES HP10, HP8,
AND HP6
HP SERIES MANUAL
HYDRAULIC HAND PUMPS
HYDRAULIC OUTPUT
PRESSURES OF: 10,000 PSI,
8,800 PSI, AND 6,000 PSI
Hand pumps are designed to match the output pressure requirements of HYPRESS
heads and cutters. Each pump is equipped
with a built-in, factory set pressure release
valve with audible click to signal completion of
crimp cycle.

BENEFITS

SPECIFICATIONS

Durable, long life expectancy.


Easy to transport and move tool around
job site with built in handle.
Maximum mechanical advantage provided
with long handle.
Solid tool base provided with sturdy broad
leg stabilizers.
Save time with quick disconnect
hydraulic fitting.
High quality crimps provided with built-in,
factory set pressure release valve and
audible click to signal completion of crimp.
5-year limited warranty.

Reservoir volume:
Length:
Width:
Weight:
Closed height:
Height (with handle open):

1-1/8 qts.
24-3/4
5
18 lbs.
6-3/4
20

FOR USE ON
HP10 10,000 Y34BH, Y35BH, Y35BH-4,
Y750BH, Y750BH-2, Y39BH,
Y45, Y45-1, Y46C, Y46,
Y60BH, Y60BHU, RHCC
Series Cutters, Y750BH
HP8

8,800

Y48BH, Y486RBH

HP6

6,000

Y35-L, Y35-L-1, Y45-L,


HCC Series cutters

ACCESSORIES
Extended leg pad stablilizes (w/hardware)
Cat # BP10PADKIT

FEATURES

HANDLE GRIP

LONG ARM

BUILT-IN FACTORY
SET PRESSURE
RELIEF VALVE
HANDLE

STURDY LEG
STABILIZERS

For CUSTOMER SERVICE call 1-800-346-4175

LIGHTWEIGHT
RUGGED DESIGN
PORTABLE

QUICK DISCONNECT
HYDRAULIC FITTING

203

BURNDY
Telecommunications Products
TYPES FP10, FP8,
AND FP6
FP SERIES MANUAL
HYDRAULIC FOOT PUMPS
HYDRAULIC OUTPUT
PRESSURES OF: 10,000 PSI,
8,800 PSI, AND 6,000 PSI
Foot pumps are designed to match the output
pressure requirements for use with all
HYPRESS heads and cutters. Each pump
is equipped with a built-in, factory set pressure release valve with audible click to signal
completion of a crimp cycle.

BENEFITS

SPECIFICATIONS

Easy to lift and carry.


Durable. Long life expectancy.
Easy to transport and move tool around
job site with built in handle.
Easy operation provided with spring
assisted return arm.
Maximum mechanical advantage
provided with long arm extending
beyond pump body.
Quality, heavy duty foot pad provided
with diamond plate steel.
Solid tool base provided with sturdy
broad leg stabilizers.
Time saving quick disconnect hydraulic
fitting.
High quality crimps provided with factory
set pressure release valve with audible
click to signal completion of crimp.
5-year limited warranty.

Reservoir volume:
Length:
Width:
Weight:
Closed height:
Height (with handle open):

1-1/8 qts.
24-3/4
5
19 lbs.
6-1/2
17

FOR USE ON
FP-10 10,000 Y34BH, Y35BH, Y35BH-4,
Y750BH, Y750BH-2, Y39BH,
Y45, Y45-1, Y46C, Y46,
Y60BH, Y60BHU, Y750BH,
RHCC Series Cutters
FP-8 8,800

Y48BH, Y486RBH

FP-6 6,000

Y35-L, Y35-L-1, Y45L,


HCC Series cutters

ACCESSORIES
Extended leg pad stablilizes (w/hardware)
Cat # BP10PADKIT

FEATURES

LONG ARM
SPRING
LOADED ARM

DIAMOND PLATE
STEEL FOOT PAD

BUILT-IN
FACTORY SET
PRESSURE
RELIEF VALVE

STURDY LEG
STABILIZERS

204

LIGHTWEIGHT
RUGGED DESIGN
PORTABLE

QUICK
DISCONNECT
HYDRAULIC
FITTING

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES EPP10 AND
EPP6

SPECIFICATIONS
Motor: 115 V-AC/60 Hz
1/2 HP @ 3450 RPM
Maximum
current draw: 12.5 amperes
Reservoir volume: 2 qts.
Height: 16
Base: 6  8
Weight: 30 lbs.

EPP SERIES ELECTRIC/


HYDRAULIC PUMP
HYDRAULIC OUTPUT
PRESSURE OF:
10,000 PSI AND 6,000 PSI
The lightweight and durable EPP10 electric/hydraulic pump is for use with all
BURNDY HYPRESS remote heads and
cutters requiring 10,000 PSI operating pressure. Both the EPP10 and the EPP6 are
equipped with a built-in, factory set pressure
relief valve. An audible pop and recycling of
the pump and relaxing of the hose, signals
completion of the crimping/cutting cycle. Both
pumps are supplied with a durable hand-held
electric pendant switch, for remote operation
of the unit, and have a manual selection
switch mounted for operation of the unit at the
pump. The operator can select which method
is best suited for the application.
An optional carry/shipping case can be
ordered. All EPP Series pumps have been life
cycle tested to over 100,000 cycles without
failure, and are warranted to be free of defects
in materials and workmanship for five (5) years
when properly maintained and operated.

FOR USE ON

FEATURES

Lightweight.
Small size.
Factory set relief valve.
100,000 (+) life cycles.
Sealed electric pendant switch.

BENEFITS
High quality crimps are achieved with
built in, factory set pressure release valve
and audible recycling of pump to signal
completion of crimp cycle.
Easy to lift, carry and transport tool
around job site with lightweight body
and handle.
Convenient 115 V-AC electric powered
motor.
Durable remote pendent switch.
Easy operation controlled with pendent
switch, or manual switch.
Saves time with quick disconnect
hydraulic fitting.
Long durable life expectancy with lightweight cast aluminum reservoir body.
5-year limited warranty.

For CUSTOMER SERVICE call 1-800-346-4175

EPP10 10,000 Y34BH, Y35BH, Y35BH-4,


Y39BH, Y45, Y45-1, Y46,
Y46C, Y60BH, Y60BHU,
750BH, Y750BH-2,
Y644MBH, RHCC Series
Cutters
EPP6

6,000

Y35L, Y28B, Y45L, HCC


Series Cutters

ACCESSORIES
Cat. No. EPPCASE-1
Steel carrying case with handle and locking
latch.

205

BURNDY
Telecommunications Products
TYPES EPAC10,
EPAC8, AND EPAC6

SPECIFICATIONS
Motor: 1/2 HP 115/230 V-AC,
60 Cycle
(EPAC**-2 versions): 1/2 HP 220/230 V-AC,
50 Cycle
Maximum current
draw: 10 amperes
Reservoir volume: 8 quarts max,
2 quarts min
Height: 17-1/2
Base: 11-3/4  18-1/2
Dry weight: 68 lbs
(82 lbs w/max fluid)
(1/2 HP @ 3450 RPM)

EPAC SERIES ELECTRIC/


HYDRAULIC PUMP,
AIR CONTROL
HYDRAULIC OUTPUT
PRESSURES OF: 10,000 PSI,
8,800 PSI, AND 6,000 PSI
The EPAC10, EPAC8, and EPAC6 electrically
driven hydraulic pumps feature exclusive
automatic or manual jog and hold operation
control provided by a unique air control
switch, which provides the safest operation
method of any pump available. All EPACs are
remotely controlled by an improved air control
switch which electrically isolates the operator
from the unit, and can be operated by either
hand or foot activation. A three (3) position
toggle switch mounted on the control box
allows the operator to select either full
automatic, off, or manual operation.
The automatic mode advances the remote
tool into a hold position without crimping the
connector so the operator can inspect the
orientation before completing the crimp. Once
the crimp is completed, the pump automatically turns off, allowing the retraction of
the remote tool and resets itself for the next
operation.
The manual position allows the operator to
jog the tool forward without the tool ram
retracting. To retract the tool prior to completing the crimp, turn the control switch to off,
the pump will stop and the tool will retract. In
the manual mode the pump advances only
while the control is being depressed. To
complete a crimp, squeeze and hold the air
control switch until the pump reaches the preset pressure and shuts off.

FEATURES

FOR USE ON

EPAC10
10,000 Y34BH, Y35BH,
EPAC10-2
Y35BH-4,Y39BH,
Y45,Y45-1,Y46,Y46-C,
Y60BH,Y60BHU,
Y750BH, Y750BH-2,
Y644MBH, RHCC
Series Cutters

Roll cage
3 position switch and control box
Factory set output pressure
Quick disconnect hydraulic coupler
Oil level window
8 quart reservoir

BENEFITS
Permits final inspection of connector
before completing crimp cycle.
Extra supply hydraulic fluid 8-quart
reservoir.
Full automatic or manual Jog and
Hold cycles.
Operator safety with power loss smart
circuit, freezes unit in event of power
disruption.
Method of operation desired is permitted
with 3-position selection switch.
Safety is provided against hazardous
shock with airbulb actuator and air line.
Saves time with quick disconnect
hydraulic fitting.
Windows allows easy inspection of
proper oil level.
High quality crimps are achieved with builtin factory set pressure release valve.
5-year limited warranty.

EPAC-8

8,800

Y48BH

EPAC-6

6,000

Y35L,Y35L-1,Y45L,
RHCC Series Cutters

The EPAC Series of electrically driven


hydraulic pumps incorporate a heavy-duty roll
cage design that is both rugged and portable.
All EPAC Series pumps have been life cycle
tested to over 100,000 cycles without failure,
and are warranted to be free of defects in
material and workmanship for five (5) years
when properly maintained and operated.

206

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES EP10, EP8,
EP6 AND EP10-2,
EP8-2, EP6-2

SPECIFICATIONS
Motor: 1/2 HP 115/230 V-AC,
60 cycle
(EP**-2 versions): 1/2 HP 220/230 V-AC,
50 cycle
Maximum current
draw: 10 amperes
Reservoir volume: 8 quarts max,
2 quarts min
Height: 17-1/2
Base: 11-3/4  18-1/2
Dry weight: 68 lbs (86 lbs with
max fluid)
(1/2 hp @ 3450 rpm)

EP SERIES ELECTRIC/
HYDRAULIC PUMPS
HYDRAULIC OUTPUT
PRESSURES OF 10,000 PSI,
8,800 PSI, AND 6,000 PSI
Electrically driven hydraulic pumps are
supplied with a durable, hand-held electric
pendent switch that remotely controls the
pump and matches the output requirements
of all HYPRESS remote heads and cutters.
Each pump is equipped with a built-in, factory
set, pressure relief valve. An audible pop
and recycling of the pump and relaxing of the
hose, signals completion of the crimping/cutting cycle.
All EP series pumps are supplied with 115/230
- 220/230 voltage, 60/50 hertz, 1/2 horsepower
motor and can be wired for use with any electric power source worldwide. A three prong,
grounded plug is wired standard on the units.
All EP Series pumps have been life cycle
tested to over 100,000 cycles without failure,
and are warranted to be free of defects in
materials and workmanship for five (5) years
when properly maintained and operated.

BENEFITS

FOR USE ON

Provides fast sure pump action plus a long


life expectancy.
Its portable. Roll cage allows easy moving
on the job site.
Durable 1/2 HP dual voltage motor.
Extra supply of hydraulic fluid with
8 quart reservoir.
Saves time with quick-disconnect
hydraulic fitting.
Easy operator control is provided with
remote pendent switch.
Easy inspection of proper oil level is
provided by see through window.
High quality crimps are achieved with
built-in, factory set, pressure release
valve and audible recycling of pump
which signals completion of crimp.
5-year limited warranty.

EP10 10,000 Y34BH, Y35BH, Y35BH-4,


EP10-2
Y39BH, Y45, Y45-1, Y46,
Y46-C, Y60BH, Y60BHU,
Y750BH, Y750BH-2, RHCC
Series Cutters
EP8
8,800
EP8-2

Y48BH

EP6
6,000
EP6-2

Y35L, Y35L-1, Y45L, RHCC


Series Cutters

FEATURES
1/2 HP MOTOR
DUAL VOLTAGE/HERTZ
ROLL CAGE

QUICK DISCONNECT
HYDRALIC COUPLER

OIL LEVEL WINDOW

8 QUART
RESERVOIR

FACTORY
SET OUTPUT
PRESSURE

For CUSTOMER SERVICE call 1-800-346-4175

207

BURNDY
Telecommunications Products
TYPES EP10-1HP,
EP8-1HP, EP6-1HP
AND EP10-1HP-2,
EP8-1HP-2, EP6-1HP-2

SPECIFICATIONS
Motor: 1/2 HP 115/230 V-AC,
60 cycle
(EP**-2 versions): 1/2 HP 220/230 V-AC,
50 cycle
Maximum current
draw: 10 amperes
Reservoir volume: 8 quarts max,
2 quarts min
Height: 17-1/2
Base: 11-3/4  18-1/2
Dry weight: 68 lbs (86 lbs
with max fluid)
(1/2 hp @ 3450 rpm)

EP-1HP SERIES ELECTRIC/


HYDRAULIC PUMPS
HYDRAULIC OUTPUT
PRESSURES OF:
10,000 PSI, 8,800 PSI,
AND 6,000 PSI
Heavy duty electrically driven hydraulic
pumps are supplied with a durable, hand-held
electric pendent switch that remotely controls
the pump and matches the output requirements of all HYPRESS remote heads and
cutters. Each pump is equipped with a builtin, factory set, pressure relief valve. An
audible pop and recycling of the pump and
relaxing of the hose, signals completion of the
crimping/cutting cycle.
All EP-1HP series pumps are supplied with
115/230 - 220/230 voltage, 60/50 hertz,
1 horsepower motors and can be wired for use
with any electric power source worldwide. A
three prong, grounded plug is wired standard
on the units. All EP-1HP Series pumps have
been life cycle tested to over 100,000 cycles
without failure, and are warranted to be free
of defects in materials and workmanship for
five (5) years when properly maintained and
operated.

208

FEATURES

FOR USE ON

EP10-1HP 10,000 Y34BH, Y35BH,


EP10-1HP-2
Y35BH-4, Y39BH,
Y45, Y451, Y46,
Y46-C, Y60BH,
Y60BHU, Y750BH,
Y750BH-2,, RHCC
Series Cutters

Heavy duty design.


Roll cage.
Quick disconnect hydraulic coupler.
Oil level window.
8 quart reservoir.
Factory set output pressure.
1 HP motor dual voltage/hertz.

BENEFITS
Provides fast sure pump action plus a long
life expectancy.
Its portable roll cage allows easy moving
on the job site.
Strong durable motor provided with
(1) H.P. dual voltage design.
Extra supply of hydraulic fluid with
8 quart reservoir.
Saves time with quick-disconnect
hydraulic fitting.
Easy operator control is provided with
remote pendant switch.
Easy inspection of proper oil level is
provided by see through window.
High quality crimps are achieved with
built-in, factory set, pressure release valve
and audible recycling of pump which
signals completion of crimp.
5-year limited warranty.

EP8-1HP
EP8-1HP-2

8,800

Y48BH

EP6-1HP

6,000

Y35L, Y35L-1, Y45L,


RHCC Series Cutters

EP6-1HP-2

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TYPES GP10,
GP8, AND GP6

Specifications
Engine:
Reservoir volume:
Pump height:
Pump width:
Pump length:
Overall height:
Overall width:
Overall length:
Pump and motor
dry weight:
Overall dry weight:

GP SERIES GASOLINE
ENGINE DRIVEN
HYDRAULIC PUMP
HYDRAULIC OUTPUT
PRESSURES OF: 10,000 PSI,
8,800 PSI, AND 6,000 PSI
The GP series gasoline engine driven
hydraulic pump is a heavy-duty design that is
rugged and portable. Supplied with a four (4)
HP engine, the pump operates all BURNDY
remote compression heads and cable cutters.
All GP style pumps have a built-in, factory
pre-set, automatic pressure release overload
valve with a definite pulsing and recycling to
signal the completion of a crimp. The manual
control valve allows user to "Jog and Hold"
due to the unique check valve design that
keeps pressure in the output line until
retracted.

4 HP, 4 cycle
2 gallons (8 qts.)
19-3/4
13
18
22-1/4
16
21
64-1/4 lbs.
77-3/4 lbs.

FOR USE ON
Pump PSI
GP10

10,000 Y34BH, Y35BH, Y35BH-4,


Y39BH, Y45, Y45-1, Y46,
Y46C, Y60BHU, Y60BHU-D,
Y750BH, Y750BH-2, RHCC
Series Cutters

GP8

8,800

Y48BH, Y486RBH

GP6

6,000

Y35L, Y35L-1, Y45L,


RHCC Series Cutters

BENEFITS
Portable pump with sturdy steel roll cage.
Durable heavy-duty four (4) H.P. engine
for all HYPRESS applications and long
life expectancy.
Manual control valve permits easy control
of crimping or cutting operations.
Manual control valve permits easy control
of crimping or cutting operations.
Fast hose assembly with quick disconnect
pressure matched hydraulic couplers.
Ample hydraulic capacity with (8) quart
reservoir.
5-year limited warranty.

Hydraulic Tools and Cutter

FEATURES
STURDY STEEL ROLL
CAGE DESIGN
HEAVY-DUTY
GASOLINE
ENGINE

MANUAL CONTROL VALVE


QUICK DISCONNECT
HYDRAULIC COUPLER

8 QUART
RESERVOIR

For CUSTOMER SERVICE call 1-800-346-4175

OIL LEVEL
INSPECTION WINDOW

209

BURNDY
Telecommunications Products
HYDRAULIC HOSES
NON CONDUCTIVE HOSES*

NON CONDUCTIVE HOSES*

CONDUCTIVE HOSES*

10,000 PSI

6,000 PSI

10,000 PSI

Cat. No.

Cat. No.

Description

PT 29900-10 10 - 3/16 diameter - non


conductive hose with stackable couplers (male/female) orange
PT 29900-15 15 - 3/16 diameter - non
conductive hose with stackable couplers (male/female) orange
PT 29900-25 25 - 3/16 diameter - non
conductive hose with stackable couplers (male/female) orange
PT 29901-10 10 - 1/4 diameter - non
conductive hose with stackable couplers (male/female) orange
PT 29901-15 15 - 1/4 diameter - non
conductive hose with stackable couplers (male/female) orange

Description

PT 29902-10 10 - non conductive hose


with stackable couplers
(male/female) - orange

Cat. No.

Description

PT 91

8 - steel braided hose


with steel spring reinforced
ends. Stackable couplers
(male/female) - Black. No
electrical rating. DO NOT
use on energized conductor.

PT 29902-15 15 - non conductive hose


with stackable couplers
(male/female) - orange
PT 29902-25 25 - non conductive hose
with stackable couplers
(male/female) - orange
PT 29074-1

Non conductive hose carrying


bag

* For proper care and maintenance of hydraulic


hoses, consult the Hydraulic Hose Care manual,
Form No. 7828

8,800 PSI
Cat No.

Description

PT 76

8 - steel braided hose


with steel spring reinforced
ends. Stackable couplers
(male/female) - Black. No
electrical rating. DO NOT
use on energized conductor.

* For proper care and maintenance of hydraulic


hoses, consult the Hydraulic Hose Care manual,
Form No. 7828.

PT 29901-25 25 - 1/4 diameter - non


conductive hose with stackable couplers (male/female) orange
NOTE: 1/4 diameter hose provides higher
flow rate for faster ram movement.
* For proper care and maintenance of hydraulic
hoses, consult the Hydraulic Hose Care manual,
Form No. 7828

Do not attempt to repair or recouple the hose yourself!


210

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
ACCESSORIES

PT 29074-1 Insulated hose carrying bag


Designed to provide protection and cleanliness of non conductive hoses. Accommodates 100 ft. of non conductive coiled to
17-1/2 O.D. and 3-3/4 wide. Max. carrying
capacity: 10 lbs.

Adjustable Head Grip For joining


HYPRESS heads to universal hot sticks
PT 29075 (for Y35L)
PT 29402-1 (for Y35BH)
PT 6547-2 (for Y45)
PT 10128 (for Y46)
PT 10131 (for Y46C)

ALFLUID
ALFLUID QT.
ALFLUID GAL.
(available in quart and gallon size containers)
Use ALFLUID in hand operated tools during extended use below 32 degrees.
All weather HYDRAULIC fluid for BURNDY
pumps:

Pressure Tee*
Y106PSI
Y108PSI

(10,000 to 6,000 PSI)


(10,000 to 8,800 PSI)

Allows use of 10,000 PSI pumps in conjunction with BURNDY 6,000 PSI and 8,800 PSI
HYPRESS tools.
Replacement Coupler 6,000 PSI operating
pressure
PT 29091 (male)
PT 29214-1 (female)

HP hand pump
FP foot pump
GP gasoline pump
EPP electric pump
AC-3H auto/man. elect. pump
DC-3H auto/man. elect. pump

* For proper care and maintenance of


hydraulic hoses, consult the Hydraulic
Hose Care manual, Form No. 7828

HYFLUID
Replacement Coupler 10,000 PSI operating
pressure
PT 94 (male)
PT 93 (female)

HYFLUID QT
HYFLUID GAL
(available in quart and gallon size containers)
Hydraulic fluid for BURNDY HYPRESS
hand operated tools:
Y35 and Y35-2 HYPRESS tools
Y39 HYPRESS tool
Y750 REVOLVER HYPRESS tools

In-line Pressure Gauge 10,000 PSI operating pressure for hydraulic pumps
PT 11018

TOOL
Y35 HYPRESS
Y35-2, Non Conductive version Y35
Y39 HYPRESS
Y750 & Y750-2, Revolver HYPRESS
Y644M, Die-less HYPRESS
(Y644 tool, obsolete)
Y35BH, 12 Ton Remote Y35
Y35BH-4, Non Conductive Y35BH tool
Y39BH, 12 Ton Remote Y39
Y750BH, 12 Ton Remote Y750
Y750BH2, Non Conductive Y750BH

For CUSTOMER SERVICE call 1-800-346-4175

TOOL CARRY CASE CAT#


#PT2972 - Steel w/ 13 die holder tray
#PT29360 - Steel w/ 13 die holder tray
#PT12814 - Steel w/ 13 die holder tray
#PT23490 - Steel w/ 13 die holder tray
#PT30539 - Steel case, no die holder tray
(#PT30007 - Steel carry case)
#PT29413 - Steel w/ 6 die holder tray
N/A, (use Y50BH-2 case, # PT23607)
#PT12821 - Steel w/ 6 die holder tray
#PT23492 - Steel w/ 6 die holder tray
#PT23607 - Steel w/ 6 die holder tray

DIE CASES (dies purchased separately)


PT 29291
(Y750, Y35/Y39) die case for
U -type die sets
PT 6545
(Y45) die case for
S -type die sets
TOOL
Y644MBH, Dieless remote
Y45, 15 Ton Remote HYPRESS
Y45, 15 Ton Remote HYPRESS
(Y45L-1, old style press)
Y46, 15 Ton Remote HYPRESS
Y46C, Non Conductive version Y46
Y60BHU, 60 Ton Remote HYPRESS
YCC-1, YCC-8, YCC-11, YCC13 Remote
Cable Cutters
YCC-22, Remote Cable Cutter
Y29BH, Remote HYPRESS
FP/HP Series Foot & Hand Pumps
(new style pumps)

TOOL CARRY CASE CAT#


#PT207190-01 - Steel, no die holder
#411-206016-014 - Steel, 1 die holder
#411-206091-018 - Steel, w/ 1 die holder
(#PT6573 - Steel, w/ 1 die holder)
#433-206016-010 - Steel, w/ 1 die holder
#433-206071-012 - Steel, w/ 1 die holder
#PT22648 - Steel, no die holders
#YCC-CASE - Steel, fits one cutter
#PT6340-1 - Steel, fits one cutter
#PT30250 - Steel, w/ die holder
#PT8 - Steel, fits Pump, Hose, and Head

211

BURNDY
Telecommunications Products
TYPE RK147-2
CONSTRUCTION/
MAINTENANCE
WIRE STRIPPERS
These lightweight strippers feature precision
ground blades that give a precise and rapid
strip for small wire applications. The RK147-2
is an adjustable stripper cutter with a simple
cam screw adjustment for multi-varied wire
sizes and insulation thickness up to #12 AWG
solid or stranded wire. The RK147-2 is part of
BURNDYs convenience package program
and is shipped on merchandising rack cards.

RK147-2
Wire Stripping Range:
Overall Length:
Weight:

212

No minimum,
up to #12 AWG
5.31
.18 lbs.

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
Y29NC
PNEUMATIC HYPRESS
The Y29NC Pneumatic
ates on 85-100 PSI and
and
uninsulated
#8-2/0 copper. Uses DV
type indentor.

HYPRESS operwill install insulated


terminals
from
type nest with Y29

BENEFITS
Portable or bench mounted.
Adjustable blow off valve to ensure proper
indenting force.
Uses DV type nest with Y29 type indentor.
Hand operated.
5-year limited warranty.

SPECIFICATIONS
Weight: 12-1/2 lbs.
Length: 17-1/2
Air line pressure: 85 100 psi

FOR USE ON
Wire Range: #82/0 Cu
YAEV-L, YAEV-H, YAEV-RS, YAEV-RH,
YAV-L,YAV-R
YAV-RS, YSV-L, YSM
DIE INDEX

NEST/INDENTER

38/631
6/631
39/632
7
40/633
9
41/634
42
43
13
44
49

DV8L/Y29PL
DV8L/Y29PL
DV6LY29PL
D6CL/Y29PL
DV4L/Y29PL
D3CL/Y29PR
DV2CL/Y29PL
DV1L/Y29PR
DV256/Y29PR
DV26L/Y29PR
DV26L/Y29PR
DV8L/Y29PL

HAND ACTUATOR
STEEL CONSTRUCTION

REMOVABLE
DIE SETS

For CUSTOMER SERVICE call 1-800-346-4175

213

BURNDY
Telecommunications Products
TFM TAPE FED
MACHINE

SPECIFICATIONS
Height:
Width:
Depth:
Weight:

FOR AUTOMATIC
INSTALLATION OF TAPE
MOUNTED TERMINALS

16
13
6
35 lbs.

FOR USE ON
#26 - #10 AWG Cu

The BURNDY TFM machine installs vinyl


insulated, nylon insulated and uninsulated
terminal sizes #26-#10 without timeconsuming die changes. A rotating turret die
holder consists of three die sets. With the new
TFM, your operators can crimp from 1,500 to
2,500 terminals per hour.
BURNDY has made a breakthrough in die
changing the TFM is the first and only turret
die holder to crimp terminals automatically.
No long complicated setups or paying for
duplicate machines: Once the dies are secure
to the die holder theres never a need to
remove them. No adjustments. No calibrations. Just a simple twist of the wrist. An
operator can change reels, terminals and
dies in seconds flat.

VINYL INSULATED TERMINALS:


BA-EF-M, BA-EL-M, BA-EM, BA-EZ-M
NYLON INSULATED TERMINALS:
YAE-M, YAE-FM, YAE-ZM
NON-INSULATED TERMINALS:
YAD-M, YAD-FM
VINYL INSULATED DISCONNECTS:
PQ-M

FEATURES

BENEFITS

Positive wire locator.


Foot-actuated crimp.
Lightweight Reel.
Quiet operation.
Lease policy.
Can crimp up to 1,500 to 2,500 terminals
per hour.
An operator can change reels, terminals
and dies in 30 seconds.
Rotating turret die holder permits terminal
change over in seconds.

Ensures proper wire termination.


Minimizes repetitive hand motion injuries.
Smooth rotation advance of connectors.
Eliminates need for earplugs/noise
dampeners.
Inexpensive alternative to buying.
High volume production capability.
Minimizes production downtime.

CAT.# TFM1D5R
(LEASE ONLY)
TWO POSITON REEL HOLDER FITS
LIGHTWEIGHT, CARDBOARD REEL.
HOLDS UP TO 2000 TERMINALS.

3-WAY
ADJUSTABLE
STAND

WARNING
LIGHT
TOOL IS IN
TFM

80-100 PSI SHOP


AIR IN (HOSE
NOT PROVIDED)

ROTATING
DIE TURRETS FOR
FASTER CHANGEOVERS

TERMINALS ARE SECURED MOUNTED


TO MYLAR FILM AND RELEASED
FROM THE FILM AFTER THE CRIMP

SMALL OPENING, FOR SAFER WIRE


INSERTION, ELIMINATES ACCIDENTS. NO FINGER CAN GET IN.

OSHA APPROVED
FOOT ACTUATED
CRIMP PEDAL
(NOT SHOWN)

110 V/AC POWER IN


(POWER CORD SUPPLIED)

214

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
TFM INSTALLATION TOOLING CHART
TAPE MOUNTED
CATALOG NO.
2000/REEL
BA16E4M
BA16E6M
BA16E8M
BA16E10M
BA16E14M
BA16E38M
BA14E4M
BA14E6M
BA14E8M
BA14E10M
BA14E14M
BA14E516M
BA14E38M
*BA10E6M
*BA10E8M
*BA10E10M
*BA10E14M
*BA10E38M

BA16EF2M
BA16EF6M
BA16EF8M
BA16EF10M
BA14EF2M
BA14EF6M
BA14EF8M
BA14EF10M
*BA10EF6M
*BA10EF8M
*BA10EF10M

INSTALLATION
TOOLING
TFM
WITH
DFM3-1
DIE

TFM
WITH
DFM2-1

TFM
WITH
DFM1D5
DIE

TFM
WITH
DFM3-1
DIE
TFM
WITH
DFM2-1
DIE
TFM
WITH
DFM1D5
DIE

TAPE MOUNTED
CATALOG NO.
2000/REEL
YAD18-4M
YAD18-6M
YAD18-8M
YAD18-10M
YAD18-14M
YAD18-516M
YAD18-38M
YAD14-4M
YAD14-6M
YAD14-8M
YAD14-10M
YAD14-14M
YAD14-516M
YAD14-38M
*YAD10-6M
*YAD10-8M
*YAD10-10M
*TAD10-14M
*YAD10-516M
*YAD10-38M

YAE22N65FM
YAE22N66FM
YAE18N60FM
YAE18G43FM
YAE18N56FM
YAE18N57FM
YAE14N76FM
YAE14N77FM
YAE14N78FM

BA16EL6M
BA16EL8M
BA16EL10M
BA14EL6M
BA14EL8M
BA14EL10M
*BA10EL6M
*BA10EL8M
*BA10EL10M

TFM WITH
DFM20D1
(20-22 AWG)
DFM3-1
(16-10 AWG)
TFM
WITH
DFM2-1
DIE
TFM
WITH
DFM1D5
DIE

* 1000 per Reel

INSTALLATION
TOOLING
TFM
WITH
DFM6-1
DIE

TFM
WITH
DFM5D1
DIE

TFM
WITH
DFM4D1
DIE

TFM
WITH
DFM11D1
DIE
TFM
WITH
DFM10D1
DIE
TFM
WITH
DFM9D1
DIE

TAPE MOUNTED
CATALOG NO.
2000/REEL
YAE22G18M
YAE22G12M
YAE22G16M
YAE22G13M
YAE22G14M
YAE22G15M
YAE18N29M
YAE18N27M
YAE18-N7M
YAE18N17M
YAE18N26M
YAE18N21M
YAE18N25M
YAE18G43M
YAE-18N24M
YAE18N1M
YAE18NM
YAE18N2M
YAE18N3M
YAE14N43M
YAE14N1M
YAE14NM
YAE14N2M
YAE14N3M
YAE14N4M
YAE12N7M
YAE12N9M
YAE12N1M
YAE12NM
YAE12N2M
YAE12N3M
*YAE10N5M
*YAE10N11M
*YAE10NM
*YAE10N3M
*YAE10N2M
*YAE10N4M
* 1000 per Reel

INSTALLATION
TOOLING

TAPE MOUNTED
CATALOG NO.
2000/REEL
YAE22Z1M

TFM
WITH
DFM11D1
DIE

YAE22Z2M
YAE22Z3M
YAE18Z1M
YAE18Z2M
YAE18Z3M
YAE18Z4M
YAE14Z2M
YAE14Z3M

TFM
WITH
DFM10D1
DIE

YAE14Z4M
YAE12Z2M
YAE12Z3M
YAE12Z4M

TFM
WITH
DFM9D1
DIE

BA16EZ2M
BA16EZ6M
BA16EZ8M
BA16EZ10M
BA14EZ2M
BA14EZ6M
BA14EZ8M
BA14EZ10M
*BA10EZ6M
*BA10EZ8M

TFM
WITH
DFM7D1
DIE

*BA10EZ10M

PQ18R257M
PQ18R258M
PQ14R257M
PQ14R258M
PQ10R258M

PQ18R256M
PQ14R256M

PQ18R187M
* 1000 per Reel

PQ18R188M
PQ14R187M
PQ14R188M

INSTALLATION
TOOLING
TFM
WITH
DFM11D1
DIE
TFM
WITH
DFM10D1
DIE
TFM
WITH
DFM9D1
DIE
TFM
WITH
DFM7D1
DIE
TFM
WITH
DFM3-1
DIE
TFM
WITH
DFM2-1
DIE
TFM
WITH
DFM1D5
DIE

TFM WITH
DFM13D1
DIE
TFM WITH
DFM12D1
DIE
TFM WITH
DFM16D1 DIE
TFM WTIH
DFM15D1 WITH
TFM WITH
DFM14D1 DIE
TFM WITH
DFM13D1
DIE
TFM WITH
DFM12D1
DIE

* 1000 per Reel

For CUSTOMER SERVICE call 1-800-346-4175

215

BURNDY
Telecommunications Products
12-TON U DIES*
BURNDY Die Sets
Fits Y35, Y39, Y750, BAT35,
BAT750, PAT750, Y46
(With PUADP-1 Adapter)
Wire Size
Small

#8
#6
#4
#3
#2
#1
1/0
2/0
3/0
4/0
250 MCM
300 MCM
350 MCM
400 MCM
500 MCM
535 Flex MCM
600 MCM
750 MCM
Large
777 Flex

Copper

Aluminum

U8CRT
U5CRT
U4CRT
U3CRT
U2CRT
U1CRT-1
U25RT
U26RT
U27RT
U28RT
U29RT
U30RT
U31RT
U32RT
U34RT
U38XRT
U36RT
U39RT
U44XRT

U8CABT
U6CABT
U4CABT
N/A
U2CABT
U1CART
U25ART
U26ART
U27ART
U28ART
U29ART
U30ART
U31ART
U32ART
U34ART
N/A
U36ART
U39ART-2
N/A

U die case Catalog# PT29291, holds up to 15 dies.

* Non-tension U-type 12-ton dies for YA, YS, YA-A, YS-A style
connectors.
NOTE: N/A = not applicable.

W DIES
BURNDY Die Sets
Fits Tools MD6, MD7,
Y500CTHS, BAT500,
BCT500HS

Small

Large

Wire Size

Copper

Aluminum

#8
#6
#4
#3
#2
#1
1/0
2/0
3/0
4/0
250
300
350
400
500

W8CVT
W5CVT
W4CVT
W3CRT
W2CVT
W1CVT
W25VT
W26VT
W27VT
W28VT
*W29VT
*W30VT
*W31VT
*W32VT
*W34VT

X8CRT
W161
W162
N/A
W239
W163
W241
W245
W166
W660
N/A
N/A
*W31ART
N/A
N/A

W die case Catalog# PT4946, holds up to 12 dies.

* These sizes (250-500) for Y500CTHS, MD7-34(R), BAT500,


BCT500 only.
NOTE: N/A = not applicable.
Suitable for use on YA, YS, YA-A, YS-A type non-tension
connectors.

216

For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
CABLE DATA
ALUMINUM-COATED STEEL CABLE
(ASTM A474)
NOMINAL DIAMETER NUMBER OF WIRES
OF STRAND (IN.)
IN STRAND
3/16
7
3/16
7
1/4
3
1/4
3
1/4
7
9/32
7
5/16
3
5/16
7
5/16
7
3/8
3
3/8
7
7/16
7
1/2
7

MINIMUM BREAKING STRENGTH, lbf


SIEMANS-MARTIN
HIGH-STRENGTH
GRADE
GRADE
COMMON GRADE
1 150
1 900
2 850

UTILITIES GRADE*

2 400
3 150
4 500

EXTRA HIGHSTRENGTH GRADE

1 900

3 150

4 750

6 650

4 600
6 500

3 200

5 350

8 000

11 200

6 000
8 500
11 500
18 000
25 000

4 250
5 350
7 400

6 950
9 350
12 100

10 800
14 500
18 800

15 400
20 800
26 900

* The Utilities Grade is used principally by communications and power and light industries.

AWG VS. METRIC WIRE SIZES


CIRC.
MILS

1020

1620
1620

2580
2580

4110
4110

6530
6530

10380
10380

13000
13090
16510
16510

20520
20520

EQUIVALENT
CIRC.
MILS
937

1480

1974
1974

2960
2960

4934
4934

7894
7894

11840
11840

19740
19740

26240
26240

33090
41740

52620
66300

STRANDING/WIRE
DIAMETER PER
STRAND

AWG.
SIZE

20

18
18

16
16

14
14

12
12

10
10

9
9
8
8

7
7

METRIC
WIRE
SIZE
MM
0.50

.075

1.0
1.0

1.5
1.5

2.5
2.5

4
4

6
6

10
10

1/.032
7/.0121
1/.039
1/.0103
7/.0152
1/.045
7/.017
1/.0503
7/.0192
1/.055
7/.021
1/.0641
7/.0242
1/.071
7/.027
1/.0308
7/.0305
1/.089
7/.034
1/.1019
7/.0355
1/.109
7/.042
1/.1144
7/.0432
1/.1285
7/.0486
1/.141
7/.054
1/.1443
7/.0545

31580

6
6

5
4

16

49340
49340

69070
69070

3
2

25
25

35
35

APPROXIMATE
OVERALL
DIAMETER
IN.

MM

1/.813
1/.307
1/.091
1/1.02
7/.386
1/1.14
7/.422
1/1.29
7/.468
1/1.40
7/5.33
1/1.63
7/.615
1/1.80
7/6.66
1/2.05
7/.775
1/2.26
7/.864
1/2.59
7/.978
1/2.77
7/.107
1/2.91
7/1.10
1/3.26
7/1.23
1/3.58
7/1.37
1/3.67
7/1.38

.032
.036
.039
.040
.046
.045
.061
.051
.058
.055
.063
.064
.073
.071
.081
.081
.092
.089
.102
.102
.116
.109
.126
.114
.130
.128
.146
.141
.162
.144
.164

.061
0.91
0.99
1.02
1.16
1.14
1.30
1.29
1.46
1.40
1.60
1.63
1.84
1.80
2.06
2.05
2.32
2.26
2.59
2.59
2.93
2.77
3..21
2.91
3.30
3.25
3.70
3.58
4.12
3.67
4.15

CIRC.
MILS
83690

10500
133100

167800
167800

211600

250 MCM
300 MCM
350 MCM

400MCM

500 MCM
500MCM

600 MCM
700MCM
750 MCM
750 MCM

800 MCM
800 MCM
1000 MCM
1000 MCM

1/.162
7/.0612
7/.008
7/.0688
7/.0772

1/4.11
7/1.55
7/1.73
7/1.75
7/1.96

.162
.184
.204
.206
.232

4.11
4.66
5.13
5.24
5.88

1250 MCM
1250 MCM
1500 MCM
1500 MCM

7/.085
19/.052
7/.0867
7/.0974
7/.100
19/.001

7/2.16
10/1.32
7/2.20
7/2.47
7/2.54
19/1.55

.255
.260
.260
.292
.300
.305

6.48
6.60
6.61
7.42
7.62
7.75

2000 MCM
2000 MCM

IN.

MM

For CUSTOMER SERVICE call 1-800-346-4175

EQUIVALENT
CIRC.
MILS

98680

138100

187500
187500

237.8 MCM

365.1 MCM

473.6 MCM
473.6 MCM

592.1 MCM

789.4 MCM

986.8 MCM

1233.7 MCM

1578.8 MCM
1973.5 MCM

AWG.
SIZE
1

1/0
2/0

3/0
3/0

4/0

STRANDING/WIRE
DIAMETER PER
STRAND

APPROXIMATE
OVERALL
DIAMETER

METRIC
WIRE
SIZE
MM

50

70

95
95

120

150

185

240
240

300

400

500

625

IN.

MM

19/.0064
19/.073
19/.0745
19/.0837
19/.086
19/.094
36/.0673
19/.101
37/.072
19/.1055
37/.081
37/.0822
37/.090
37/.0973
37/.100
37/104
37/.114
61/.089
37/.1162
61/.0905
61/.099
61/.0992
61/.1071
61/.1109
91/.0908
61/.114
61/.1145
91/.0938
61/.1280
91/.1048
91/.117

19/1.50
19/1.85
19/1.59
19/2.13
19/2.18
19/2.59
37/1.71
19/2.57
37/1.83
19/2.89
37/2.06
37/2.07
37/2.29
37/2.47
37/2.54
37/2.64
37/2.90
61/2.26
37/2.95
61/2.30
61/2.51
61/2.52
61/2.72
61/2.82
91/2.31
61/2.90
61/2.91
91/2.38
61/3.25
91/2.66
91/2.97

.332
.365
.373
.419
.430
.470
.471
.505
.504
.528
.567
.575
.630
.681
.700
.728
.798
.801
.813
.814
.891
.893
.964
.998
.998
1.026
1.031
1.032
1.152
1.153
1.287

8.43
9.27
9.46
10.6
10.9
11.9
12.0
12.8
12.5
13.4
14.4
14.6
16.0
17.3
17.8
18.5
20.3
20.3
20.7
20.7
22.6
22.7
24.5
25.4
25.4
26.1
26.2
26.2
28.3
29.3
32.7

800

91/.1172
127/.0992
91/.1284
127/.1087
91/.132

91/2.93
127/2.52
91/3.26
127/2.76
91/3.35

1.289
1.200
1.412
1.413
1.452

32.7
32.8
36.9
36.9
36.9

1000

91/.147
127/.1255
169/.1088

91/3.73
127/3.19
169/2.76

1.617
1.632
1.632

41.1
41.5
41.5

IN.

MM

217

BURNDY
Telecommunications Products
INCHES & MILLIMETERS CONVERSION CHART
INCHES
1
64
1
32

1
16

3
32

1
9
64
5
32

3
16

7
32

1
17
64
9
32

5
16

11
32

3
8

13
32

7
16

15
32

5.556

6.350

3
4
64
25
32

7.144

7.938

64
13
16
64
27
32

8.731

9.525

7
8

29
32

10.319

11.113

15
16

31
32

11.906

.5000

12.700

1
1mm = .03937

218

23.019

.921875 23.416
23.813

.953125 24.209
.96875

63
64

.484375 12.303

22.225

.890625 22.622

.9375
61
64

21.431

.859375 21.828

.90625
59
64

20.638

.828125 21.034

.8750
57
64

19.844

.796875 20.241

.84375
55
64

19.050

.765625 19.447

.8125
53

18.256

.734375 18.653

.78125
51

17.463

.703125 17.859

.7500
49

16.669

.671875 17.066

.71875
47
64

.453125 11.509
.46875

31
64

23
32

.421875 10.716
.4375

29
64

45
64

15.875

.640625 16.272

.6875

.390625 9.922
.40625

27
64

4.763

11
16

15.081

.609375 15.478

.65625
43
64

.359375 9.128
.3750

25
64

3.969

.328125 8.334
.34375

23
64

21
32

.296875 7.541
.3125

21
64

41
64

14.288

.578125 14.684

.6250

.265625 6.747
.28125

19
64

3.175

5
8

13.494

.546875 13.891

.59375
39
64

.234375 5.953
.2500

19
32

.203125 5.159
.21875

15
64

37
64

2.381

.515625 13.097

.5625

.171875 4.366
.1875

13
64

9
16

.140625 3.572
.15625

11
64

1.588

MILLIMETERS

.53125
35
64

.109375 2.778
.1250

17
32

0.794

.078125 1.984
.09375

7
64

33
64

.046875 1.191
.0625

5
64

INCHES

.015625 0.397
.03125

3
64

1
2

MILLIMETERS

24.606

.984375 25.003
1.000

25.400

MM
.1
.2
.3
.4
.5
.6
.7
.8
.9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45

INCHES

MM

.0039
.0079
.0118
.0157
.0197
.0236
.0276
.0315
.0354
.0394
.0787
.1181
.1575
.1969
.2362
.2756
.3150
.3543
.3937
.4331
.4724
.5118
.5512
.5906
.6299
.6693
.7087
.7480
.7874
.8268
.8661
.9055
.9449
.9843
1.0236
1.0630
1.1024
1.1417
1.1811
1.2205
1.2598
1.2992
1.3386
1.3780
1.4173
1.4567
1.4961
1.5354
1.5748
1.6142
1.6535
1.6929
1.7323
1.7717

46
47
48
48
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100

INCHES

1.8110
1.8504
1.8898
1.9291
1.9685
2.0079
2.0472
2.0866
2.1260
2.1654
2.2047
2.2441
2.2835
2.3228
2.3622
2.4016
2.4409
2.4803
2.5197
2.5591
2.5984
2.6378
2.6772
2.7165
2.7559
2.7953
2.8346
2.8740
2.9134
2.9528
2.9921
3.0315
3.0709
3.1102
3.1496
3.1890
3.2283
3.2677
3.3071
3.3465
3.3858
3.4252
3.4646
3.5039
3.5433
3.5827
3.6220
3.6614
3.7008
3.7402
3.7795
3.8189
3.8583
3.8976
3.9370

.001 = .0254 mm.


For CUSTOMER SERVICE call 1-800-346-4175

BURNDY
Telecommunications Products
ALPHA-NUMERIC INDEX
CATALOG NO.
25 FW BOX
25 NW BOX
25 SW BOX
25C HEN BOX
25x100 HEB BOX
25x125 HEB BOX
25x150 HEB BOX
25x200 HEB BOX
25x250 HEB BOX
25x300 HEB BOX
25x50 HEB BOX
25x62 HEB BOX
25x75 HEB BOX
29279-2
31 FW BOX
31 NW BOX
31 SW BOX
31C HEN BOX
31x100 HEB BOX
31x125 HEB BOX
31x150 HEB BOX
31x175 HEB BOX
31x200 HEB BOX
31x250 HEB BOX
31x300 HEB BOX
31x50 HEB BOX
31x62 HEB BOX
31x75 HEB BOX
38 FW BOX
38 NW BOX
38 SW BOX
38 X (*) HEB
38C HEN BOX
38CHEN
38SW
38x100 HEB BOX
38x125 HEB BOX
38x150 HEB BOX
38x175 HEB BOX
38x200 HEB BOX
38x225 HEB BOX
38x250 HEB BOX
38x275 HEB BOX
38x300 HEB BOX
38x325 HEB BOX
38x350 HEB BOX
38x400 HEB BOX
38x450 HEB BOX
38x50 HEB BOX
38x500 HEB BOX
38x62 HEB BOX
38x75 HEB BOX
38x88 HEB BOX
411-206016-014
411-206091-018
433-206016-010
433-206071-012
44 FW BOX
44 NW BOX
44 SW BOX
44C HEN BOX
44x150 HEB BOX
44x200 HEB BOX
50 FW BOX
50 NW BOX
50 SW BOX
50 X (*) HEB
50C HEN BOX
50CHEN
50SW
50x100 HEB BOX
50x125 HEB BOX
50x150 HEB BOX
50x175 HEB BOX

PAGE NO.
163
163
163
162
162
162
162
162
162
162
162
162
162
185
163
163
163
162
162
162
162
162
162
162
162
162
162
162
163
163
163
145
162
145
145
162
162
162
162
162
162
162
162
162
162
162
162
162
162
162
162
162
162
211
211
211
211
163
163
163
162
162
162
163
163
163
145
162
145
145
162
162
162
162

CATALOG NO.
50x200 HEB BOX
50x225 HEB BOX
50x250 HEB BOX
50x275 HEB BOX
50x300 HEB BOX
50x325 HEB BOX
50x350 HEB BOX
50x375 HEB BOX
50x400 HEB BOX
50x450 HEB BOX
50x500 HEB BOX
50x550 HEB BOX
50x600 HEB BOX
50x75 HEB BOX
62 FW BOX
62 NW BOX
62 SW BOX
62 X (*) HEB
62C HEN BOX
62CHEN
62SW
62x100 HEB BOX
62x125 HEB BOX
62x150 HEB BOX
62x175 HEB BOX
62x200 HEB BOX
62x225 HEB BOX
62x250 HEB BOX
62x275 HEB BOX
62x300 HEB BOX
62x325 HEB BOX
62x350 HEB BOX
62x400 HEB BOX
62x450 HEB BOX
62x500 HEB BOX
62x600 HEB BOX
75 X (*) HEB
75C HEN BOX
75CHEN
75SW
ALFLUID GAL
ALFLUID QT
B2D12
B2D12N
B2E12
B2E12N
B2F12
B2F12N
B2G12
B2G12N
B3D12
B3D12N
B3E12
B3E12N
B3F12
B3F12N
B3G12
B3G12N
B4D12
B4D12N
B4E12
B4E12N
B4F12
B4F12N
B4G12
B4G12N
BA10E10
BA10E10M
BA10E14
BA10E14M
BA10E38
BA10E38M
BA10E6
BA10E6M

PAGE NO.
162
162
162
162
162
162
162
162
162
162
162
162
162
162
163
163
163
145
162
145
145
162
162
162
162
162
162
162
162
162
162
162
162
162
162
162
145
162
145
145
211
211
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
159
2
2
2
2
2
2
2
2

CATALOG NO.
BA10E8
BA10E8M
BA10EF10
BA10EF10M
BA10EF6
BA10EF6M
BA10EF8
BA10EF8M
BA10EL10
BA10EL10M
BA10EL6
BA10EL6M
BA10EL8
BA10EL8M
BA10EZ10
BA10EZ10M
BA10EZ6
BA10EZ6M
BA10EZ8
BA10EZ8M
BA14E10
BA14E10M
BA14E14
BA14E14M
BA14E38
BA14E38M
BA14E4
BA14E4M
BA14E516
BA14E516M
BA14E6
BA14E6M
BA14E8
BA14E8M
BA14EF10
BA14EF10M
BA14EF2
BA14EF2M
BA14EF6
BA14EF6M
BA14EF8
BA14EF8M
BA14EL10
BA14EL10M
BA14EL6
BA14EL6M
BA14EL8
BA14EL8M
BA14EZ10
BA14EZ10M
BA14EZ2
BA14EZ2M
BA14EZ6
BA14EZ6M
BA14EZ8
BA14EZ8M
BA16E10
BA16E10M
BA16E14
BA16E14M
BA16E38
BA16E38M
BA16E4
BA16E4M
BA16E6
BA16E6M
BA16E8
BA16E8M
BA16EF10
BA16EF10M
BA16EF2
BA16EF2M
BA16EF6
BA16EF6M

PAGE NO.
2
2
16
16
16
16
16
16
18
18
18
18
18
18
17
17
17
17
17
17
2
2
2
2
2
2
2
2
2
2
2
2
2
2
16
16
16
16
16
16
16
16
18
18
18
18
18
18
17
17
17
17
17
17
17
17
2
2
2
2
2
2
2
2
2
2
2
2
16
16
16
16
16
16

CATALOG NO.
PAGE NO.
BA16EF8
16
BA16EF8M
16
BA16EL10
18
BA16EL10M
18
BA16EL6
18
BA16EL6M
18
BA16EL8
18
BA16EL8M
18
BA16EZ10
17
BA16EZ10M
17
BA16EZ2
17
BA16EZ2M
17
BA16EZ6
17
BA16EZ6M
17
BA16EZ8
17
BA16EZ8M
17
BAT12B
194
BAT18V
188, 189, 190, 191
BAT18VLED
189, 190, 191
BATCHGR
194
BATCHGR-18V
188
BCC1000CUAL
193
BCCBAT12V
193
BCCCASE
193
BCCCHGR
193
BCT/PATDCCHGR 188, 189,
190, 191
BD12
158
BD12N
158
BD18
158
BD18N
158
BD24
158
BD24N
158
BE12
158
BE12N
158
BE18
158
BE18N
158
BE24
158
BE24N
158
BET13
171
BET27
171
BETHEAD
171
BETSPACER
171
BETSTRAP
171
BF12
158
BF12N
158
BF18
158
BF18N
158
BF24
158
BF24N
158
BG12
158
BG12N
158
BG18
158
BG18N
158
BG24
158
BG24N
158
BP10PADKIT
203, 204
BS10
23
BS14
23
BS16
23
CCFBC-FR
121
CCFBG-FR
123, 124
CCFD-FR
121, 123, 124
CCFN-FR
121, 123, 124
CCFO-FR
121, 123, 124
CCFR-FR
121, 123, 124
CFBG-FR
121, 123, 124
CFD-FR
120
CFD-FR
121, 123, 124
CFN-FR
120
CFN-FR
121, 123, 124
CFO-FR
120
CFO-FR
121, 123, 124
CFR-FR
120

CATALOG NO.
PAGE NO.
CFR-FR
121, 123, 124
CT120200D
166
CT120200D0
166
CT120200L
166
CT120200L0
166
CT120300D
166
CT120300D0
166
CT120300L
166
CT120300L0
166
CT120400D
166
CT120400D0
166
CT120400L
166
CT120400L0
166
CT120400MH14D
168
CT120400MH14D0
168
CT120400MH14L
168
CT120400MH14L0
168
CT120900D
166
CT120900D0
166
CT120900L
166
CT120900L0
166
CT1751100Q
166
CT1751100Q0
166
CT1751400Q
166
CT1751400Q0
166
CT175400Q
166
CT175400Q0
166
CT175600Q
166
CT175600Q0
166
CT175900Q
166
CT175900Q0
166
CT18075C
165
CT18075C0
165
CT18075FLC
168
CT18075IDC
168
CT18075M
165
CT18075M0
165
CT18075MH4C
168
CT18075MH4C0
168
CT18075MH4M
168
CT18075MH4M0
168
CT18125C
165
CT18125C0
165
CT18125M
165
CT18125M0
165
CT18200C
165
CT18200C0
165
CT18200M
165
CT18200M0
165
CT2501000Q
166
CT2501000Q0
166
CT2501000RQ
167
CT2501000RQ0
167
CT2501200Q
166
CT2501200Q0
166
CT2501200RQ
167
CT2501200RQ0
167
CT250200RQ
167
CT250200RQ0
167
CT250500RQ
167
CT250500RQ0
167
CT250600Q
166
CT250600Q0
166
CT250600RQ
167
CT250600RQ0
167
CT250800Q
166
CT250800Q0
166
CT250800RQ
167
CT250800RQ0
167
CT30125C
165
CT30125C0
165
CT30125M
165
CT30125M0
165
CT30125MH8C
168

219

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
CT30125MH8C0
168
CT30125MH8M
168
CT30125MH8M0
168
CT30125PMC
170
CT30125PMC0
170
CT30125PMM
170
CT30125PMM0
170
CT40200C
165
CT40200C0
165
CT40200M
165
CT40200M0
165
CT40200RC
167
CT40200RC0
167
CT40300C
165
CT40300C0
165
CT40300M
165
CT40300M0
165
CT40400C
165
CT40400C0
165
CT40400M
165
CT40400M0
165
CT50137EPRC
167
CT50137EPRC0
167
CT50137RC
167
CT50137RC0
167
CT50175C
165
CT50175C0
165
CT50175ID2L
168
CT50175ID3L
168
CT50175IDC
168
CT50175M
165
CT50175M0
165
CT50175MH10C
168
CT50175MH10C0
168
CT50175MH10M
168
CT50175MH10M0
168
CT50175PMC
170
CT50175PMC0
170
CT50175PMM
170
CT50175PMM0
170
CT50250EPRC
167
CT50250EPRC0
167
CT50300C
165
CT50300C0
165
CT50300M
165
CT50300M0
165
CT50400C
165
CT50400C0
165
CT50400IDC
168
CT50400M
165
CT50400M0
165
CT50400MH10C
168
CT50400MH10C0
168
CT50400MH10M
168
CT50400MH10M0
168
CT50400RC
167
CT50400RC0
167
CTAS1000
171
CTAS1600
171
CTAS750
171
CTB075AA4C
173
CTB075AA4M
173
CTB075RA4C
173
CTB075RA4M
173
CTB075S4C
173
CTB075S4M
173
CTB125AA4C
173, 206
CTB125AA4D
173
CTB125RA2C
173
CTB125RA4C
173
CTB125RA4D
173
CTB125RA4L
173
CTB125S2C
173
CTB125S4C
173
CTB125S4D
173
CTB150AA4B
173

220

CATALOG NO.
CTB150AA4C
CTB150RA4B
CTB150RA4C
CTB150S4B
CTB150S4C
CTH120400D
CTH120400L
CTH18075C
CTH18075M
CTH30200C
CTH30200M
CTH50175C
CTH50175M
CTSS1001000C
CTSS100200C
CTSS100400C
CTSS100600C
CTSS100800C
CTSS2501000Q
CTSS250200L
CTSS250400L
CTSS250600L
CTSS250800L
CTZ120400D
CTZ120400L
CTZ18075C
CTZ18075M
CTZ30200C
CTZ30200M
CTZ50175C
CTZ50175M
CUSA442NTC
CUSA442TC38
EP10
EP10-1HP
EP10-1HP-2
EP10-2
EP6
EP6-1HP
EP6-1HP-2
EP6-2
EP8
EP8-1HP
EP8-1HP-2
EP8-2
EPAC-8
EPAC10
EPAC10-2
EPAC6
EPP10
EPP6
EPPCASE-1
FP10
FP6
FP8
FQN10F25X03B
FQN10F25X03D
FQN10M25X03B
FQN10M25X03D
FQN14F25X03B
FQN14F25X03D
FQN14M25X03B
FQN14M25X03D
FQN18F25X03B
FQN18F25X03D
FQN18M25X03B
FQN18M25X03D
GAR1126
GAR1129
GAR114C
GAR1426
GAR1429
GAR1434
GAR144C
GAR1526
GAR1529

PAGE NO.
173
173
173
173
173
169
169
169
169
169
169
169
169
170
170
170
170
170
170
170
170
170
170
169
169
169
169
169
169
169
169
111
111
207
208
208
207
207
208
208
207
207
208
208
207
206
206
206
206
205
205
205
204
204
204
29
29
29
29
29
29
29
29
29
29
29
29
151
151
151
151
151
151
151
151
151

CATALOG NO.
GAR1534
GAR154C
GAR1626
GAR1629
GAR1634
GAR164C
GAR1726
GAR1729
GAR1734
GAR174C
GAR1826
GAR1829
GAR1834
GAR184C
GAR1926
GAR1929
GAR1934
GAR194C
GAR2026
GAR2029
GAR2034
GAR204C
GAR2126
GAR2129
GAR2134
GAR214C
GAR2226
GAR2229
GAR2234
GAR224C
GAR2426
GAR2429
GAR2434
GAR244C
GAR3902
GAR3902-BU
GAR3902TC
GAR3903
GAR3903-BU
GAR3903TC
GAR3904
GAR3904-BU
GAR3904TC
GAR3905
GAR3905-BU
GAR3905TC
GAR3906
GAR3906-BU
GAR3906TC
GAR3907
GAR3907-BU
GAR3907TC
GAR3908
GAR3908-BU
GAR3908TC
GAR3909
GAR3909-BU
GAR3909TC
GAR6426
GAR6429
GAR6434
GAR644C
GAR644C-RB
GAR8629
GD1526
GD1529
GD1626
GD1629
GD1726
GD1729
GD1734
GD174C
GD1826
GD1829
GD1834
GD184C

PAGE NO.
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
152
152
152
152
152
152
152
152
152
152
152
152
152
152
152
152
153
153
154
153
153
154
153
153
154
153
153
154
153
153
154
153
153
154
153
153
154
153
153
154
151
151
151
151
153
152
155
155
155
155
155
155
155
155
155
155
155
155

CATALOG NO.
GD1926
GD1929
GD1934
GD194C
GD2026
GD2029
GD2034
GD204C
GD2126
GD2129
GD2134
GD214C
GD2226
GD2229
GD2234
GD224C
GG15-1
GG16-1
GG17-1
GG17-15
GG18-1
GG18-15
GG18-2
GG19-2
GG19-25
GG20-2
GG20-25
GG20-3
GG21-2
GG21-25
GG21-3
GG21-35
GG22-2
GG22-25
GG22-3
GG22-35
GG22-4
GG24-2
GK1126
GK1129
GK114C
GK1426
GK1429
GK1434
GK1526
GK1529
GK1626
GK1629
GK1726
GK1729
GK1826
GK1829
GK1926
GK1929
GK6426
GK6429
GK6434
GK644C
GP10
GP1126
GP1129
GP114C
GP1426
GP1429
GP1434
GP144C
GP1526G1
GP1629
GP164C
GP1726
GP1726RT
GP1826
GP184C
GP2026
GP2226
GP6

PAGE NO.
155
155
155
155
155
155
155
155
155
155
155
155
155
155
155
155
157
157
157
157
157
157
157
157
157
157
157
157
157
157
157
157
157
157
157
157
157
157
156
156
156
156
156
156
156
156
156
156
156
156
156
156
156
156
156
156
156
156
209
156
156
156
156
156
156
156
161
156
156
156
161
156
156
156
156
209

CATALOG NO.
PAGE NO.
GP6426
156
GP6429
156
GP6434
156
GP644C
156
GP64526G1
161
GP654CG1
161
GP8
209
GRF4C-3
160
GRF4C-4
160
HFB33-4N
147
HFB33P1
145, 147
HFB44-4N
147
HFB44P1
145, 147
HFB63P1
145
HFB66-6N
147
HFB66P1
145, 147
HFB88P1
145
HFBW32T5CG1
146
HFBW42T10CG1
146
HFBW43T10CG1
146
HFBW44T17CG1
146
HFBW62T10CG1
146
HFBW63T10CG1
146
HFBW64T17CG1
146
HFBW66T16CG1
146
HFBW86T20CG1
146
HH5-RL48
185
HP10
203
HP6
203
HP8
203
HYFLUID GAL
211
HYFLUID QT
211
K2C15
121, 123, 148
K2C15B1
121, 123, 148
K2C17
121, 123, 148
K2C17B1
121, 123, 148
K2C20
121, 123, 148
K2C20B1
121, 123, 148
K2C22
148
K2C22B1
148
K2C23
148
K2C23B1
148
K2C25
148
K2C25B1
148
K2C26
148
K2C26B1
148
K2C28
148
K2C28B1
148
K2C31
148
K2C31B1
148
K2C34
148
K2C34B1
148
KC15
148
KC15B1
121, 148
KC17
121, 148
KC17B1
121, 148
KC20
121, 148
KC20B1
121, 148
KC22
121, 148
KC22B1
121, 148
KC23
121, 148
KC23B1
121, 148
KC25
121, 148
KC25B1
121, 148
KC26
121, 148
KC26B1
121, 123, 148
KC28
121, 123, 148
KC28B1
121, 123, 148
KC31
121, 123, 148
KC31B1
121, 123, 148
KC34
148
KC34B1
121, 123, 148
KS15-DB
149
KS17-DB
149
KS20-DB
149
KS22-DB
149

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
KS23-DB
149
KS25-DB
149
KS26-DB
149
KS27-DB
149
KS29-DB
149
KS31-DB
149
KS34-DB
149
KSU17
150
KSU20
150
KSU22
150
KSU23
150
KSU25
150
KSU26
150
KSU27
150
KSU29
150
KSU31
150
KSU34
150
LPHTADPSMFOP66 197, 198
LPHTHOSNCR666610 197, 198
LPHTHOSNCR666610OP 197, 198
LPHTHOSNCR66668 197, 198
LPHTHOSNCR66668OP197, 198
LPHTHTMABODY66 197, 198
LPHTHTMANOSE66 197, 198
LPHY46
198
LPHY750
197
MCC1000
201
MCC500
201
MD6-6R
182
MD6-6R-2
182
MD6-8R
182
MD6-CP1
181
MD6R
182
MD7-34
180
MD7-34-KIT1
180
MD7-34R
180
MD7-34R-KIT 1
180
MR15
178
MR18
178
MR20
178
MRTOOLKIT
178
NQ10M250D
28
P15K
198, 199
PAT600C-18V
189
PAT750C-18V
188
PATCHGR18V 189, 190, 191
PATCHGR250V 189, 190, 191
PATCUT129ACSR-18V
190
PATCUT245CUAL-18V
191
PPH175GRY
125
PPH350BLU
125
PPH350GRY
125
PPH50BLK
125
PPH50GRY
125
PPH50RED
125
PT 10128
211
PT 10131
211
PT 11018
211
PT 29074-1
210, 211
PT 29075
211
PT 29091
211
PT 29214-1
211
PT 29291
211
PT 29402-1
211
PT 29900-10
210
PT 29900-15
210
PT 29900-25
210
PT 29901-10
210
PT 29901-15
210
PT 29901-25
210
PT 29902-10
210
PT 29902-15
210
PT 29902-25
210
PT 6545
211
PT 6547-2
211
PT 76
210

CATALOG NO.
PAGE NO.
PT 91
210
PT 93
211
PT 94
211
PT10024162
192
PT10037384
190, 192, 200
PT10037388
190, 192, 200
PT10038657
191
PT10040663
191
PT10043890
200
PT10044980
191
PT10121
199
PT10128
199
PT10131
199
PT12814
211
PT12821
211
PT17188
182
PT207190-01
211
PT208620
188-191
PT22648
211
PT23484
196
PT23490
211
PT23492
211
PT23607
211
PT29291
185, 216
PT29360
185, 211
PT29413
211
PT2972
185, 211
PT30007
211
PT30250
211
PT30539
211
PT4925
181, 182
PT4931-1
181
PT4946
181, 216
PT4952-1
181
PT6340-1
211
PT6573
211
PT6733
181, 185
PT6744
181
PT8
211
PUADP-1
198, 199
Q10F25X03B
30
Q10F25X03D
30
Q14F11X02B
30
Q14F11X02D
30
Q14F18X02B
30
Q14F18X02D
30
Q14F25X03B
30
Q14F25X03D
30
Q14M18X02B
30
Q14M18X02D
30
Q14M25X03B
30
Q14M25X03D
30
Q18F18X02B
30
Q18F18X02D
30
Q18F25X03B
30
Q18F25X03D
30
Q18M18X02B
30
Q18M18X02D
30
Q18M25X03B
30
Q18M25X03D
30
QN10F25X03B
28
QN10F25X03D
28
QN14F11X02B
28
QN14F11X02D
28
QN14F18X02B
28
QN14F18X02D
28
QN14F25X03B
28
QN14F25X03D
28
QN14M18X02B
28
QN14M18X02D
28
QN14M25X03B
28
QN14M25X03D
28
QN18F18X02B
28
QN18F18X02D
28
QN18F25X03B
28
QN18F25X03D
28

CATALOG NO.
QN18M18X02B
QN18M18X02D
QN18M25X03B
QN18M25X03D
QP10F25X03B
QP10F25X03D
QP10M250D
QP14F18X02B
QP14F18X02D
QP14F25X03B
QP14F25X03D
QP14M18X02B
QP14M18X02D
QP14M25X03B
QP14M25X03D
QP18F18X02B
QP18F18X02D
QP18F25X03B
QP18F25X03D
QP18M18X02B
QP18M18X02D
QP18M25X03B
QP18M25X03D
RCC1000
RCC556
RHCC129ACSR
RK147-2
RP50RP02
RP50RP03
SN10
SN14
SN18
SNM14
SNM18
SP10
SP14
SP16
TFM1D5R
TFV3B12V2
TFV3B18V2
TFV3BLU12
TFV3BLU18
TMH261
TMH261SS
TMH262
TMH262SS
TMH263
TMH263SS
TMH264
TMH264SS
TMH265
TMH265SS
TMH266
TMH266SS
TMH267
TMH267SS
TMH268
TMH268SS
TMH269
TMH269SS
TMH270
TMH270SS
TMH271
TMH271SS
TMH272
TMH272SS
TMH289
TMH289SS
TMH294
TMH294SS
TMH295
TMH295SS
TMH322SS
TMH323
TMH323SS
TMH332

PAGE NO.
28
28
28
28
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
202
202
200
212
193
193
24
24
24
25
25
23
23
23
214
172
172
172
172
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
164
111

CATALOG NO.
TMH332
TMH69
TMH69SS
TMHG-42
TMHG-92
TN10-10
TN10-10F
TN10-14
TN10-14F
TN10-38
TN10-516
TN10-6
TN10-6F
TN10-8
TN10-8F
TN14-10
TN14-10F
TN14-14
TN14-14F
TN14-38
TN14-4
TN14-516
TN14-6
TN14-6F
TN14-8
TN14-8F
TN18-10
TN18-10F
TN18-14
TN18-14F
TN18-38
TN18-4
TN18-516
TN18-6
TN18-6F
TN18-8
TN18-8F
TN20-2F
TN20-6F
TP10-10
TP10-10F
TP10-10LF
TP10-10Z
TP10-14
TP10-38
TP10-6
TP10-6F
TP10-6LF
TP10-6Z
TP10-8
TP10-8F
TP10-8LF
TP10-8Z
TP14-10
TP14-10F
TP14-10LF
TP14-10Z
TP14-14
TP14-2F
TP14-2Z
TP14-38
TP14-4
TP14-516
TP14-6
TP14-6F
TP14-6LF
TP14-6Z
TP14-8
TP14-8F
TP14-8LF
TP14-8Z
TP16-10
TP16-10F
TP16-10LF
TP16-10Z
TP16-14

PAGE NO.
164
164
164
142
142
3
19
3
19
3
3
3
19
3
19
3
19
3
19
3
3
3
3
19
3
19
3
19
3
19
3
3
3
3
19
3
19
19
19
2
16
18
17
2
2
2
16
18
17
2
16
18
17
2
16
18
17
2
16
17
2
2
2
2
16
18
17
2
16
18
17
2
16
18
17
2

CATALOG NO.
TP16-2F
TP16-2Z
TP16-38
TP16-4
TP16-6
TP16-6F
TP16-6LF
TP16-6Z
TP16-8
TP16-8F
TP16-8LF
TP16-8Z
U1CART
U1CRT-1
U25ART
U25RT
U26ART
U26RT
U27ART
U27RT
U28ART
U28RT
U29ART
U29RT
U2CABT
U2CRT
U30ART
U30RT
U31ART
U31RT
U32ART
U32RT
U34ART
U34RT
U36ART
U36RT
U38XRT
U39ART-2
U39RT
U3CRT
U44XRT
U4CABT
U4CRT
U5CRT
U6CABT
U8CABT
U8CRT
W-28K
W-687
W-702
W-BG
W161
W162
W163
W166
W1CVT
W239
W241
W245
W25VT
W26VT
W27VT
W28VT
W29VT
W2CVT
W30VT
W31ART
W31VT
W32VT
W34VT
W3CRT
W4CVT
W5CVT
W660
W8CVT
WDA8300

PAGE NO.
16
17
2
2
2
16
18
17
2
16
18
17
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
181
181
181
181
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
216
183

221

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
WDC4500
183
WDIETREE
181, 189
X8CRT
216
Y10-22
176
Y106PSI
211
Y108PSI
211
Y10D
175
Y1MRTC
179
Y1MRTCKIT
179
Y29NC
213
Y34A
185
Y35
184
Y35-16
185
Y35-2
184
Y35/Y39 REP KIT A
185
Y35B
195
Y35BH
195
Y35BH-4
195
Y35H
195
Y35P3
185
Y39
186
Y420DC-1B
194
Y46
199
Y46-2
199
Y46C
199
Y500CT-HS
183
Y700DC-1B
194
Y750-2HS
187
Y750BH
196
Y750BH-2
196
Y750HS
187
Y750HSCASE
187
Y8MRB-1
177
YA-453L
39
YA-453L-45
39
YA-453L-90
39
YA-45L
39
YA-45L-45
39
YA-45L-90
39
YA1C
42
YA1C-2L
70
YA1C-2L-45
70
YA1C-2L-90
70
YA1C-2LN
70
YA1C-2LN-45
70
YA1C-2LN-90
70
YA1C-45
42
YA1C-90
42
YA1C-LB
56
YA1C-N
42
YA1C-N-45
42
YA1C-N-90
42
YA1C-TC10
42
YA1C-TC10-45
42
YA1C-TC10-90
42
YA1C2N
78
YA1C2N-45
78
YA1C2N-90
78
YA1C2TC14
78
YA1C2TC14-45
78
YA1C2TC14-90
78
YA1C2TC14E2
78
YA1C2TC14E2-45
78
YA1C2TC14E2-90
78
YA1C2TC38
78
YA1C2TC38-45
78
YA1C2TC38-90
78
YA1CL-2TC14
70
YA1CL-2TC14-45
70
YA1CL-2TC14-90
70
YA1CL-2TC14E2
70
YA1CL-2TC14E2-45
70
YA1CL-2TC14E2-90
70
YA1CL-2TC38
71
YA1CL-2TC38-45
71
YA1CL-2TC38-90
71

222

CATALOG NO.
PAGE NO.
YA1CL-45
35
YA1CL-90
35
YA1CL-BOX
35
YA1CL2
35
YA1CL2-45
35
YA1CL2-90
35
YA1CL2NT14E2
75
YA1CL4-45
35
YA1CL4-90
35
YA1CL4-BOX
35
YA1CL6-45
35
YA1CL6-90
35
YA1CL6-BOX
35
YA1CLNT10
40
YA1CLNT14
40
YA25
42
YA25-2L
71
YA25-2L-45
71
YA25-2L-90
71
YA25-45
42
YA25-90
42
YA25-LB
56
YA252LN
71
YA252LN-45
71
YA252LN-90
71
YA252N
78
YA252N-45
78
YA252N-90
78
YA252NTC38
78
YA252NTC38-45
78
YA252NTC38-90
78
YA252TC14
78
YA252TC14-45
78
YA252TC14-90
78
YA252TC14E2
78
YA252TC14E2-45
78
YA252TC14E2-90
78
YA252TC38
78
YA252TC38-45
78
YA252TC38-90
78
YA252TC516
78
YA252TC516-45
78
YA252TC516-90
78
YA25L-2TC14
71
YA25L-2TC14-45
71
YA25L-2TC14-90
71
YA25L-2TC14E1
71
YA25L-2TC14E1-45
71
YA25L-2TC14E1-90
71
YA25L-2TC14E2
71
YA25L-2TC14E2-45
71
YA25L-2TC14E2-90
71
YA25L-2TC38
71
YA25L-2TC38-45
71
YA25L-2TC38-90
71
YA25L-45
36
YA25L-4TCG1
109
YA25L-90
36
YA25L-BOX
36
YA25L2-45
36
YA25L2-90
36
YA25L2-BOX
36
YA25L2NT14E1
75
YA25L2NT14E145
75
YA25L2NT14E190
75
YA25L4-45
36
YA25L4-90
36
YA25L4-BOX
36
YA25L6-45
36
YA25L6-90
36
YA25L6-BOX
36
YA25LNT10
40
YA25LNT516
40
YA25N
43
YA25N-45
43
YA25N-90
43

CATALOG NO.
PAGE NO.
YA25TC10
42
YA25TC10-45
42
YA25TC10-90
42
YA25TC38
42
YA25TC38-45
42
YA25TC38-90
42
YA26
43
YA26-2L
71
YA26-2L-45
71
YA26-2L-90
71
YA26-45
43
YA26-90
43
YA26-LB
56
YA262LN
71
YA262LN-45
71
YA262LN-90
71
YA262N
78
YA262N-45
78
YA262N-90
78
YA262TC14
78
YA262TC14-45
78
YA262TC14-90
78
YA262TC14E2
78
YA262TC14E2-45
78
YA262TC14E2-90
78
YA262TC38
79
YA262TC38-45
79
YA262TC38-90
79
YA26L-2TC14
71
YA26L-2TC14-45
71
YA26L-2TC14-90
71
YA26L-2TC14E1
71
YA26L-2TC14E1-45
71
YA26L-2TC14E1-90
71
YA26L-2TC14E2
71
YA26L-2TC14E2-45
71
YA26L-2TC14E2-90
71
YA26L-2TC38
71
YA26L-2TC38-45
71
YA26L-2TC38-90
71
YA26L-45
36
YA26L-4TCG1
109
YA26L-90
36
YA26L-BOX
36
YA26L2-45
36
YA26L2-90
36
YA26L2-BOX
36
YA26L2NT14
75
YA26L2NT14E1
75
YA26L3-45
36
YA26L3-90
36
YA26L3-BOX
36
YA26L6-45
36
YA26L6-90
36
YA26L6-BOX
36
YA26L60
36
YA26L60-45
36
YA26L60-90
36
YA26L7-45
36
YA26L7-90
36
YA26L7-BOX
36
YA26LNT10
40
YA26LNT38
40
YA26LNT516
36, 40
YA26LNT516U
40
YA26N
43
YA26N-45
43
YA26N-90
43
YA27
43
YA27-45
43
YA27-90
43
YA27-LB
56
YA272LN
71
YA272LN-45
71
YA272LN-90
71
YA272N
79

CATALOG NO.
PAGE NO.
YA272N-45
79
YA272N-90
79
YA272TC14E2
79
YA272TC14E2-45
79
YA272TC14E2-90
79
YA272TC38
79
YA272TC38-45
79
YA272TC38-90
79
YA27L-2TC14E2
71
YA27L-2TC14E2-45
71
YA27L-2TC14E2-90
71
YA27L-2TC38
71
YA27L-2TC38-45
71
YA27L-2TC38-90
71
YA27L-45
36
YA27L-4TCG1
109
YA27L-90
36
YA27L-BOX
36
YA27L2-45
36
YA27L2-90
36
YA27L2-BOX
36
YA27L3
36
YA27L3-45
36
YA27L3-90
36
YA27L4-45
36
YA27L4-90
36
YA27L4-BOX
36
YA27LNT38
36, 40
YA28
43
YA28-2L516
72
YA28-2L516-45
72
YA28-2L516-90
72
YA28-45
43
YA28-90
43
YA28-LB
56
YA282LN
72
YA282LN-45
72
YA282LN-90
72
YA282N
79
YA282N-45
79
YA282N-90
79
YA282NTC38
79
YA282NTC38-45
79
YA282NTC38-90
79
YA282TC14E2
79
YA282TC14E2-45
79
YA282TC14E2-90
79
YA282TC38
79
YA282TC38-45
79
YA282TC38-90
79
YA28L-2TC14E1
72
YA28L-2TC14E1-45
72
YA28L-2TC14E1-90
72
YA28L-2TC14E2
72
YA28L-2TC14E2-45
72
YA28L-2TC14E2-90
72
YA28L-2TC38
72
YA28L-2TC38-45
72
YA28L-2TC38-90
72
YA28L-2TC38E2
72
YA28L-2TC38E2-45
72
YA28L-2TC38E2-90
72
YA28L-45
37
YA28L-4TCG1
109
YA28L-90
37
YA28L-BOX
37
YA28L17-45
36
YA28L17-90
36
YA28L17-BOX
36
YA28L2-45
36
YA28L2-90
37
YA28L2-BOX
36
YA28L3-45
37
YA28L3-90
37
YA28L3-BOX
37
YA28L4-45
37

CATALOG NO.
PAGE NO.
YA28L4-90
37
YA28L4-BOX
37
YA28L56-45
37
YA28L56-90
37
YA28L56-BOX
37
YA28LNT38
37, 40
YA28TC38
43
YA28TC38-45
43
YA28TC38-90
43
YA29
43
YA29-45
43
YA29-90
43
YA29-LB
56
YA292LN
72
YA292LN-45
72
YA292LN-90
72
YA292N
79
YA292N-45
79
YA292N-90
79
YA292TC38
79
YA292TC38-45
79
YA292TC38-90
79
YA29L-2TC38
72
YA29L-2TC38-45
72
YA29L-2TC38-90
72
YA29L-45
37
YA29L-4TCG1
109
YA29L-90
37
YA29L-BOX
37
YA29L2
37
YA29L2-45
37
YA29L2-90
37
YA29L4
37
YA29L4-45
37
YA29L4-90
37
YA29L7
37
YA29L7-45
37
YA29L7-90
37
YA29LENT38
40
YA29LNT38
37, 40
YA29LTC78
37
YA29LTC78-45
37
YA29LTC78-90
37
YA2C
42
YA2C-2L
70
YA2C-2L-45
70
YA2C-2L-90
70
YA2C-2LN
70
YA2C-2LN-45
70
YA2C-2LN-90
70
YA2C-45
42
YA2C-90
42
YA2C-LB
56
YA2C-N
42
YA2C-N-45
42
YA2C-N-90
42
YA2C-TC10
42
YA2C-TC10-45
42
YA2C-TC10-90
42
YA2C-TC14
42
YA2C-TC14-45
42
YA2C-TC14-90
42
YA2C2N
77
YA2C2N-45
77
YA2C2N-90
77
YA2C2NTC38
77
YA2C2NTC38-45
77
YA2C2NTC38-90
77
YA2C2TC14
77
YA2C2TC14-45
77
YA2C2TC14-90
77
YA2C2TC14E2
77
YA2C2TC14E2-45
77
YA2C2TC14E2-90
77
YA2C2TC38
78
YA2C2TC38-45
78

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YA2C2TC38-90
78
YA2C2TC38E2
77
YA2C2TC38E2-45
77
YA2C2TC38E2-90
77
YA2C2TC38E6
78
YA2C2TC38E6-45
78
YA2C2TC38E6-90
78
YA2C2TC516E2
77, 78
YA2C2TC516E2-45
77, 78
YA2C2TC516E2-90
77, 78
YA2CL-2TC14
70
YA2CL-2TC14-45
70
YA2CL-2TC14-90
70
YA2CL-2TC14E1
70
YA2CL-2TC14E1-45
70
YA2CL-2TC14E1-90
70
YA2CL-2TC14E2
70
YA2CL-2TC14E2-45
70
YA2CL-2TC14E2-90
70
YA2CL-2TC38
70
YA2CL-2TC38-45
70
YA2CL-2TC38-90
70
YA2CL-2TC516
70
YA2CL-2TC516-45
70
YA2CL-2TC516-90
70
YA2CL-45
35
YA2CL-90
35
YA2CL-BOX
35
YA2CL2-45
35
YA2CL2-90
35
YA2CL2-BOX
35
YA2CL2NT14
75
YA2CL2NT1445
75
YA2CL2NT1490
75
YA2CL2NT14E1
75
YA2CL2NT14E145
75
YA2CL2NT14E190
75
YA2CL2NT14E2
75
YA2CL4-45
35
YA2CL4-90
35
YA2CL4-BOX
35
YA2CL6-45
35
YA2CL6-90
35
YA2CL6-BOX
35
YA2CLNT10
40
YA2CLNT14
40
YA2CLNT516
40
YA30
43
YA30-45
43
YA30-90
43
YA30-L2NTC-FX
93
YA30-L2NTC-FX-45
93
YA30-L2NTC-FX-90
93
YA30-L2TC12-FX
93
YA30-L2TC12-FX-45
93
YA30-L2TC12-FX-90
93
YA30-L2TC38-FX
93
YA30-L2TC38-FX-45
93
YA30-L2TC38-FX-90
93
YA30-LB
56
YA30-TC12-FXB
63
YA302LN
72
YA302LN-45
72
YA302LN-90
72
YA302N
79
YA302N-45
79
YA302N-90
79
YA302N-FXB
104
YA302TC38
79
YA302TC38-45
79
YA302TC38-90
79
YA302TC38-FXB
104
YA30L
37
YA30L-2TC-38
72
YA30L-2TC-38-45
72
YA30L-2TC-38-90
72

CATALOG NO.
PAGE NO.
YA30L-45
37
YA30L-90
37
YA30L-TC12-FX
53
YA30L-TC12-FX-45
53
YA30L-TC12-FX-90
53
YA30L-TC34-FX
54
YA30L-TC34-FX-45
54
YA30L-TC34-FX-90
54
YA30L-TC38-FX
53
YA30L-TC38-FX-45
53
YA30L-TC38-FX-90
53
YA30L-TC516-FX
53
YA30L-TC516-FX-45
53
YA30L-TC516-FX-90
53
YA30L-TC58-FX
53
YA30L-TC58-FX-45
53
YA30L-TC58-FX-90
53
YA30L1
37
YA30L1-45
37
YA30L1-90
37
YA30L24
37
YA30L24-45
37
YA30L24-90
37
YA30L27
37
YA30L27-45
37
YA30L27-90
37
YA30L28
37
YA30L7
37
YA30L7-45
37
YA30L7-90
37
YA30LNT38
40
YA31
43
YA31-45
43
YA31-90
43
YA31-L2NTC-FX
94
YA31-L2NTC-FX-45
94
YA31-L2NTC-FX-90
94
YA31-L2NTC38-FX
94
YA31-L2NTC38-FX-45
94
YA31-L2NTC38-FX-90
94
YA31-L2TC12-FX
94
YA31-L2TC12-FX-45
94
YA31-L2TC12-FX-90
94
YA31-L2TC38-FX
94
YA31-L2TC38-FX-45
94
YA31-L2TC38-FX-90
94
YA31-LB
56
YA31-TC12-FXB
63
YA312LN
72
YA312LN-45
72
YA312LN-90
72
YA312N
79
YA312N-45
79
YA312N-90
79
YA312N-FXB
104
YA312TC14E2
79
YA312TC14E2-45
79
YA312TC14E2-90
79
YA312TC38
79
YA312TC38-45
79
YA312TC38-90
79
YA312TC38-FXB
104
YA31L
37
YA31L-2NTC516
72
YA31L-2NTC516-45
72
YA31L-2NTC516-90
72
YA31L-2TC12
72
YA31L-2TC12-45
72
YA31L-2TC12-90
72
YA31L-2TC14E2
72
YA31L-2TC14E2-45
72
YA31L-2TC14E2-90
72
YA31L-2TC38
72
YA31L-2TC38-45
72
YA31L-2TC38-90
72
YA31L-45
37

CATALOG NO.
PAGE NO.
YA31L-4TCG1
109
YA31L-90
37
YA31L-NT12-FX
54
YA31L-NT12-FX-45
54
YA31L-NT12-FX-90
54
YA31L-TC12-FX
54
YA31L-TC12-FX-45
54
YA31L-TC12-FX-90
54
YA31L-TC14-FX
54
YA31L-TC14-FX-45
54
YA31L-TC14-FX-90
54
YA31L-TC34-FX
54
YA31L-TC34-FX-45
54
YA31L-TC34-FX-90
54
YA31L-TC38-FX
54
YA31L-TC38-FX-45
54
YA31L-TC38-FX-90
54
YA31L-TC516-FX
54
YA31L-TC516-FX-45
54
YA31L-TC516-FX-90
54
YA31L-TC58-FX
54
YA31L-TC58-FX-45
54
YA31L-TC58-FX-90
54
YA31L11
38
YA31L11-45
38
YA31L11-90
38
YA31L2NT38
75
YA31L36
38
YA31L36-45
38
YA31L36-90
38
YA31L7
38
YA31L7-45
38
YA31L7-90
38
YA31LNT38
38, 40
YA32
43
YA32-2L
73
YA32-2L-45
73
YA32-2L-90
73
YA32-45
43
YA32-90
43
YA32-L2NTC-FX
94
YA32-L2NTC-FX-45
94
YA32-L2NTC-FX-90
94
YA32-L2TC38-FX
94
YA32-L2TC38-FX-45
94
YA32-L2TC38-FX-90
94
YA32-LB
56
YA32-TC12-FXB
64
YA32-TC58-FXB
64
YA322LN
72
YA322LN-45
72
YA322LN-90
72
YA322N
79
YA322N-45
79
YA322N-90
79
YA322N-FXB
104
YA322TC38
80
YA322TC38-45
80
YA322TC38-90
80
YA322TC38-FXB
104
YA32L
38
YA32L-2TC38
73
YA32L-2TC38E5
73
YA32L-2TC38E5-45
73
YA32L-2TC38E5-90
73
YA32L-45
38
YA32L-90
38
YA32L-TC12-FX
54
YA32L-TC12-FX-45
54
YA32L-TC12-FX-90
54
YA32L-TC38-FX
54
YA32L-TC38-FX-45
54
YA32L-TC38-FX-90
54
YA32L-TC58-FX
54
YA32L-TC58-FX-45
54
YA32L-TC58-FX-90
54

CATALOG NO.
PAGE NO.
YA32L1
38
YA32L1-45
38
YA32L1-90
38
YA32L14
38
YA32L14-45
38
YA32L14-90
38
YA32LNT38
40
YA32LTC78
38
YA32LTC78-45
38
YA32LTC78-90
38
YA32N
43
YA32N-45
43
YA32N-90
43
YA33
44
YA33-2LN
73
YA33-2LN-45
73
YA33-2LN-90
73
YA33-45
44
YA33-90
44
YA33-N
44
YA33-N-45
44
YA33-N-90
44
YA332N
80
YA332N-45
80
YA332N-90
80
YA33L
38
YA33L-45
38
YA33L-90
38
YA34
44
YA34-2L
73
YA34-2L-45
73
YA34-2L-90
73
YA34-45
44
YA34-90
44
YA34-L2NT38-FX
94
YA34-L2NT38-FX-45
94
YA34-L2NT38-FX-90
94
YA34-L2NTC-FX
94
YA34-L2NTC-FX-45
94
YA34-L2NTC-FX-90
94
YA34-L2NTC38-FX
94
YA34-L2NTC38-FX-45
94
YA34-L2NTC38-FX-90
94
YA34-L2TC12-FX
94
YA34-L2TC12-FX-45
94
YA34-L2TC12-FX-90
94
YA34-L2TC38-FX
94
YA34-L2TC38-FX-45
94
YA34-L2TC38-FX-90
94
YA34-L2TC516-FX
94
YA34-L2TC516-FX-45
94
YA34-L2TC516-FX-90
94
YA34-LB
56
YA34-TC12-FXB
64
YA34-TC58-FXB
64
YA342LN
73
YA342LN-45
73
YA342LN-90
73
YA342N
80
YA342N-45
80
YA342N-90
80
YA342N-FXB
104
YA342N-FXB-45
104
YA342N-FXB-90
104
YA342TC14E2
80
YA342TC14E2-45
80
YA342TC14E2-90
80
YA342TC14E2-FXB
104
YA342TC38
80
YA342TC38-45
80
YA342TC38-90
80
YA342TC38-FXB
104
YA34L
38
YA34L-2TC12
73
YA34L-2TC12-45
73
YA34L-2TC12-90
73

CATALOG NO.
PAGE NO.
YA34L-2TC14E2
73
YA34L-2TC14E2-45
73
YA34L-2TC14E2-90
73
YA34L-2TC38
73
YA34L-2TC38-45
73
YA34L-2TC38-90
73
YA34L-45
38
YA34L-90
38
YA34L-TC12-FX
54
YA34L-TC12-FX-45
54
YA34L-TC12-FX-90
54
YA34L-TC38-FX
54
YA34L-TC38-FX-45
54
YA34L-TC38-FX-90
54
YA34L-TC516-FX
54
YA34L-TC516-FX-45
54
YA34L-TC516-FX-90
54
YA34L-TC58-FX
54
YA34L-TC58-FX-45
54
YA34L-TC58-FX-90
54
YA34L20
38
YA34L20-45
38
YA34L20-90
38
YA34L2NT38
75
YA34L37
38
YA34L37-45
38
YA34L37-90
38
YA34L6
38
YA34L6-45
38
YA34L6-90
38
YA34L8
38
YA34L8-45
38
YA34L8-90
38
YA34L9
38
YA34L9-45
38
YA34L9-90
38
YA34LNT38
40
YA34N
44
YA34N-45
44
YA34N-90
44
YA35
44
YA35-2L
73
YA35-2L-45
73
YA35-2L-90
73
YA35-2LN
73
YA35-2LN-45
73
YA35-2LN-90
73
YA35-45
44
YA35-90
44
YA35-N
44
YA35-N-45
44
YA35-N-90
44
YA352N
80
YA352N-45
80
YA352N-90
80
YA35L
38
YA35L-45
38
YA35L-90
38
YA36
44
YA36-45
44
YA36-90
44
YA36-L2NTC-FX
94
YA36-L2NTC-FX-45
94
YA36-L2NTC-FX-90
94
YA36-L2TC38-FX
94
YA36-L2TC38-FX-45
94
YA36-L2TC38-FX-90
94
YA36-LB
56
YA36-TC12-FXB
64
YA36-TC58-FXB
64
YA362LN
73
YA362LN45
73
YA362LN90
73
YA362N
80
YA362N-45
80
YA362N-90
80

223

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YA362TC38
80
YA362TC38-45
80
YA362TC38-90
80
YA36L
38
YA36L-2TC38
73
YA36L-2TC38-45
73
YA36L-2TC38-90
73
YA36L-45
38
YA36L-90
38
YA36L-TC12-FX
54
YA36L-TC12-FX-45
54
YA36L-TC12-FX-90
54
YA36L-TC58-FX
55
YA36L-TC58-FX-45
55
YA36L-TC58-FX-90
55
YA36L11
38
YA36LNT38
40
YA36LTC78
39
YA36LTC78-45
39
YA36LTC78-90
39
YA36N
44
YA36N-45
44
YA36N-90
44
YA37
44
YA37-2L
73
YA37-2L-45
73
YA37-2L-90
73
YA37-2LN
73
YA37-2LN-45
73
YA37-2LN-90
73
YA37-45
44
YA37-90
44
YA37-N
44
YA37-N-45
44
YA37-N-90
44
YA372N
80
YA372N-45
80
YA372N-90
80
YA37L
39
YA37L-45
39
YA37L-90
39
YA37L1
39
YA38
44
YA38-2L
73
YA38-2L-45
73
YA38-2L-90
73
YA38-2LN
73
YA38-2LN-45
73
YA38-2LN-90
73
YA38-45
44
YA38-90
44
YA38-L2NNT-FX
95
YA38-L2NNT-FX-45
95
YA38-L2NNT-FX-90
95
YA38-L2NT38-FX
95
YA38-L2NT38-FX-45
95
YA38-L2NT38-FX-90
95
YA38-L2NTC-FX
95
YA38-L2NTC-FX-45
95
YA38-L2NTC-FX-90
95
YA38-L2TC12-FX
94
YA38-L2TC12-FX-45
94
YA38-L2TC12-FX-90
94
YA38-L2TC38-FX
94
YA38-L2TC38-FX-45
94
YA38-L2TC38-FX-90
94
YA38-L2TC516-FX
95
YA38-L2TC516-FX-45
95
YA38-L2TC516-FX-90
95
YA38-LB
56
YA38-N
44
YA38-N-45
44
YA38-N-90
44
YA38-TC58-FXB
64
YA382-FXBG2
104
YA382-FXBG3
104

224

CATALOG NO.
PAGE NO.
YA382N
80
YA382N-45
80
YA382N-90
80
YA382N-FXB
104
YA382N-FXB-45
104
YA382N-FXB-90
104
YA382TC38
80
YA382TC38-45
80
YA382TC38-90
80
YA382TC38-FXB
104
YA382TC38-FXB-45
104
YA382TC38-FXB-90
104
YA38L
39
YA38L-2TC12
74
YA38L-2TC12-45
74
YA38L-2TC12-90
74
YA38L-2TC38
74
YA38L-2TC38-45
74
YA38L-2TC38-90
74
YA38L-45
39
YA38L-90
39
YA38L-TC12-FX
55
YA38L-TC12-FX-45
55
YA38L-TC12-FX-90
55
YA38L-TC38-FX
55
YA38L-TC38-FX-45
55
YA38L-TC38-FX-90
55
YA38L-TC516-FX
55
YA38L-TC516-FX-45
55
YA38L-TC516-FX-90
55
YA38L-TC58-FX
55
YA38L-TC58-FX-45
55
YA38L-TC58-FX-90
55
YA39
44
YA39-45
44
YA39-90
44
YA39-L2NTC-FX
95
YA39-L2NTC-FX-45
95
YA39-L2NTC-FX-90
95
YA39-LB
56
YA392L
74
YA392L-45
74
YA392L-90
74
YA392LN
74
YA392LN-90
74
YA392LN45
74
YA392N
80
YA392N-45
80
YA392N-90
80
YA392NT38
80
YA392NT38-45
80
YA392NT38-90
80
YA392TC38
80
YA392TC38-45
80
YA392TC38-90
80
YA39L
39
YA39L-2TC12E3
74
YA39L-2TC12E3-45
74
YA39L-2TC12E3-90
74
YA39L-2TC38
74
YA39L-2TC38-45
74
YA39L-2TC38-90
74
YA39L-2TC58
74
YA39L-2TC58-45
74
YA39L-2TC58-90
74
YA39L-45
39
YA39L-90
39
YA39L2
39
YA39L2-45
39
YA39L2-90
39
YA39L2NT38
75
YA39L2NT3845
75
YA39L2NT3890
75
YA39L6
39
YA39L6-45
39
YA39L6-90
39

CATALOG NO.
PAGE NO.
YA39L9
39
YA39L9-45
39
YA39L9-90
39
YA39LNT38
39, 40
YA39N
44
YA39N-45
44
YA39N-90
44
YA3C
42
YA3C-2L
70
YA3C-2L-45
70
YA3C-2L-90
70
YA3C-45
42
YA3C-90
42
YA3C-LB
56
YA3C-TC14
42
YA3C-TC14-45
42
YA3C-TC14-90
42
YA3C-TC38
42
YA3C-TC38-45
42
YA3C-TC38-90
42
YA3C2N
77
YA3C2N-45
77
YA3C2N-90
77
YA3C2N-FXB
103
YA3C2TC14
77
YA3C2TC14-45
77
YA3C2TC14-90
77
YA3C2TC14E2
77
YA3C2TC14E2-45
77
YA3C2TC14E2-90
77
YA3C2TC38
77
YA3C2TC38-45
77
YA3C2TC38-90
77
YA3C2TC38-FXB
103
YA3C2TC38E2
77
YA3C2TC38E2-45
77
YA3C2TC38E2-90
77
YA3C2TC516-FXB
103
YA3CL
35
YA3CL-2TC14
70
YA3CL-2TC14-45
70
YA3CL-2TC14-90
70
YA3CL-2TC38
70
YA3CL-2TC38-45
70
YA3CL-2TC38-90
70
YA3CL-45
35
YA3CL-90
35
YA3CLNT516
40
YA3CN
42
YA3CN-45
42
YA3CN-90
42
YA40
44
YA40-2L
74
YA40-2L-45
74
YA40-2L-90
74
YA40-45
44
YA40-90
44
YA40-L2NNT-FX
95
YA40-L2NNT-FX-45
95
YA40-L2NNT-FX-90
95
YA40-L2NTC-FX
95
YA40-L2NTC-FX-45
95
YA40-L2NTC-FX-90
95
YA40-L2TC38-FX
95
YA40-L2TC38-FX-45
95
YA40-L2TC38-FX-90
95
YA40-LB
56
YA40-N
44
YA40-N-45
44
YA40-N-90
44
YA40-TC58-FXB
64
YA402LN
74
YA402LN-45
74
YA402LN-90
74
YA402N
80
YA402N-45
80

CATALOG NO.
PAGE NO.
YA402N-90
80
YA402N-FXB
104
YA40L
39
YA40L-2TC38
74
YA40L-2TC38-45
74
YA40L-2TC38-90
74
YA40L-45
39
YA40L-90
39
YA40L-TC12-FX
55
YA40L-TC12-FX-45
55
YA40L-TC12-FX-90
55
YA40L-TC38-FX
55
YA40L-TC38-FX-45
55
YA40L-TC38-FX-90
55
YA40L-TC516-FX
55
YA40L-TC516-FX-45
55
YA40L-TC516-FX-90
55
YA40L-TC58-FX
55
YA40L-TC58-FX-45
55
YA40L-TC58-FX-90
55
YA41
45
YA41-2L
74
YA41-2L-45
74
YA41-2L-90
74
YA41-45
45
YA41-90
45
YA41-N
45
YA41-N-45
45
YA41-N-90
45
YA412N
80
YA412N-45
80
YA412N-90
80
YA41L
39
YA41L-45
39
YA41L-90
39
YA44
45
YA44-2L
74
YA44-2L-45
74
YA44-2L-90
74
YA44-45
45
YA44-90
45
YA44-L2NNT-FX
95
YA44-L2NNT-FX-45
95
YA44-L2NNT-FX-90
95
YA44-L2NT38-FX
95
YA44-L2NT38-FX-45
95
YA44-L2NT38-FX-90
95
YA44-L2NTC-FX
95
YA44-L2NTC-FX-45
95
YA44-L2NTC-FX-90
95
YA44-L2TC12-FX
95
YA44-L2TC12-FX-45
95
YA44-L2TC12-FX-90
95
YA44-L2TC12E3-FX
95
YA44-L2TC12E3-FX-45
95
YA44-L2TC12E3-FX-90
95
YA44-L2TC38-FX
95
YA44-L2TC38-FX-45
95
YA44-L2TC38-FX-90
95
YA44-L2TC58-FX
95
YA44-L2TC58-FX-45
95
YA44-L2TC58-FX-90
95
YA44-LB
56
YA44-N
45
YA44-N-45
45
YA44-N-90
45
YA44-TC58-FXB
64
YA442LN
74
YA442LN-45
74
YA442LN-90
74
YA442N
81
YA442N-45
81
YA442N-90
81
YA442N-FXB
104
YA442TC38
81
YA442TC38-45
81

CATALOG NO.
PAGE NO.
YA442TC38-90
81
YA442TC38-FXB
104
YA44L
39
YA44L-2TC12
74
YA44L-2TC12-45
74
YA44L-2TC12-90
74
YA44L-45
39
YA44L-90
39
YA44L-TC12-FX
55
YA44L-TC12-FX-45
55
YA44L-TC12-FX-90
55
YA44L-TC58-FX
55
YA44L-TC58-FX-45
55
YA44L-TC58-FX-90
55
YA44L2
39
YA44L23
39
YA45
45
YA45-45
45
YA45-90
45
YA45-N
45
YA45-N-45
45
YA45-N-90
45
YA452N
81
YA452N-45
81
YA452N-90
81
YA4532N
81
YA4532N-45
81
YA4532N-90
81
YA46
45
YA46-45
45
YA46-90
45
YA46-N
45
YA46-N-45
45
YA46-N-90
45
YA46-TC58-FXB
64
YA462N
81
YA462N-45
81
YA462N-90
81
YA462N-FXB
104
YA46L
39
YA46L-45
39
YA46L-90
39
YA47
45
YA47-45
45
YA47-90
45
YA47-N
45
YA47-N-45
45
YA47-N-90
45
YA472N
81
YA472N-45
81
YA472N-90
81
YA47L
39
YA47L-45
39
YA47L-90
39
YA48
45
YA48-45
45
YA48-90
45
YA48-N
45
YA48-N-45
45
YA48-N-90
45
YA482N
81
YA482N-45
81
YA482N-90
81
YA48L
39
YA48L-45
39
YA48L-90
39
YA4C
41
YA4C-2L
69
YA4C-2L-45
69
YA4C-2L-90
69
YA4C-2LN
70
YA4C-2LN-45
70
YA4C-2LN-90
70
YA4C-45
41
YA4C-90
42
YA4C-LB
56

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YA4C-N
42
YA4C-N-45
42
YA4C-N-90
42
YA4C-TC10
41
YA4C-TC10-45
41
YA4C-TC10-90
41
YA4C-TC38
42
YA4C-TC38-45
42
YA4C-TC38-90
42
YA4C2N
77
YA4C2N-45
77
YA4C2N-90
77
YA4C2TC14
77
YA4C2TC14-45
77
YA4C2TC14-90
77
YA4C2TC14E2
77
YA4C2TC14E2-45
77
YA4C2TC14E2-90
77
YA4C2TC38
77
YA4C2TC38-45
77
YA4C2TC38-90
77
YA4CL-2TC14
69
YA4CL-2TC14-45
69
YA4CL-2TC14-90
69
YA4CL-2TC14E1
69
YA4CL-2TC14E1-45
69
YA4CL-2TC14E1-90
69
YA4CL-2TC14E2
70
YA4CL-2TC14E2-45
70
YA4CL-2TC14E2-90
70
YA4CL-2TC38
69
YA4CL-2TC38-45
69
YA4CL-2TC38-90
69
YA4CL-2TC516
70
YA4CL-2TC516-45
70
YA4CL-2TC516-90
70
YA4CL-45
35
YA4CL-90
35
YA4CL-BOX
35
YA4CL1-45
35
YA4CL1-90
35
YA4CL1-BOX
35
YA4CL3-45
35
YA4CL3-90
35
YA4CL3-BOX
35
YA4CL4-45
35
YA4CL4-90
35
YA4CL4-BOX
35
YA4CL6-45
35
YA4CL6-90
35
YA4CL6-BOX
35
YA4CLNT10
40
YA5C
41
YA5C-2L
69
YA5C-2L-45
69
YA5C-2L-90
69
YA5C-45
41
YA5C-90
41
YA5C-LB
56
YA5C-N
41
YA5C-N-45
41
YA5C-N-90
41
YA5C2N
77
YA5C2N-45
77
YA5C2N-90
77
YA5CL-45
35
YA5CL-90
35
YA5CL-BOX
35
YA6C
41
YA6C-2L
69
YA6C-2L-45
69
YA6C-2L-90
69
YA6C-2L51
69
YA6C-2L51-45
69
YA6C-2L51-90
69
YA6C-2L52
69

CATALOG NO.
PAGE NO.
YA6C-2L52-45
69
YA6C-2L52-90
69
YA6C-2LN
69
YA6C-2LN-45
69
YA6C-2LN-90
69
YA6C-45
41
YA6C-90
41
YA6C-N
41
YA6C-N-45
41
YA6C-N-90
41
YA6C-TC10
41
YA6C-TC10-45
41
YA6C-TC10-90
41
YA6C2N
76
YA6C2N-45
76
YA6C2N-90
76
YA6C2TC14
76
YA6C2TC14-45
76
YA6C2TC14-90
76
YA6C2TC14E1
76
YA6C2TC14E1-45
76
YA6C2TC14E1-90
76
YA6C2TC14E2
76
YA6C2TC14E2-45
76
YA6C2TC14E2-90
76
YA6C2TC38
76
YA6C2TC38-45
76
YA6C2TC38-90
76
YA6C2TC38E2
76
YA6C2TC38E2-45
76
YA6C2TC38E2-90
76
YA6C2TC38E6
76
YA6C2TC38E6-45
76
YA6C2TC38E6-90
76
YA6CL-2TC10
69
YA6CL-2TC10-45
69
YA6CL-2TC10-90
69
YA6CL-2TC14
69
YA6CL-2TC14-45
69
YA6CL-2TC14-90
69
YA6CL-2TC14E
69
YA6CL-2TC14E-45
69
YA6CL-2TC14E-90
69
YA6CL-2TC14E1
69
YA6CL-2TC14E1-45
69
YA6CL-2TC14E1-90
69
YA6CL-2TC14E2
69
YA6CL-2TC14E2-45
69
YA6CL-2TC14E2-90
69
YA6CL-2TC38
69
YA6CL-2TC38-45
69
YA6CL-2TC38-90
69
YA6CL-2TC516
69
YA6CL-2TC516-45
69
YA6CL-2TC516-90
69
YA6CL-2TC516E2
69
YA6CL-2TC516E2-45
69
YA6CL-2TC516E2-90
69
YA6CL-45
34
YA6CL-90
34
YA6CL-BOX
34
YA6CL1-45
34
YA6CL1-90
34
YA6CL1-BOX
34
YA6CL3-45
34
YA6CL3-90
34
YA6CL3-BOX
34
YA6CL4-45
35
YA6CL4-90
35
YA6CL4-BOX
35
YA6CL6-45
35
YA6CL6-90
35
YA6CL6-BOX
35
YA6CLNT6
40
YA8C-2LN
68
YA8C-2LN-45
68

CATALOG NO.
PAGE NO.
YA8C-2LN-90
68
YA8C-L1-45
50
YA8C-L1-90
50
YA8C-L1-BOX
50
YA8C-L2-45
50
YA8C-L2-90
50
YA8C-L2-BOX
50
YA8C-L3-45
50
YA8C-L3-90
50
YA8C-L3-BOX
50
YA8C-L4-45
50
YA8C-L4-90
50
YA8C-L4-BOX
50
YA8C-LB
56
YA8C-TC10
41
YA8C-TC10-45
41
YA8C-TC10-90
41
YA8C-TC10-FXB
63
YA8C-TC14
41
YA8C-TC14-45
41
YA8C-TC14-90
41
YA8C-TC14-FXB
63
YA8C-TC38
41
YA8C-TC38-45
41
YA8C-TC38-90
41
YA8C2TC14
76
YA8C2TC14-45
76
YA8C2TC14-90
76
YA8C2TC14-FXB
103
YA8C2TC14E2
76
YA8C2TC14E2-45
76
YA8C2TC14E2-90
76
YA8C2TC14E2-FXB
103
YA8C2TC38
76
YA8C2TC38-45
76
YA8C2TC38-90
76
YA8C2TC38-FXB
103
YA8CL-2TC10
68
YA8CL-2TC10-45
68
YA8CL-2TC10-90
68
YA8CL-2TC10E2
68
YA8CL-2TC10E2-45
68
YA8CL-2TC10E2-90
68
YA8CL-2TC14
68
YA8CL-2TC14-45
68
YA8CL-2TC14-90
68
YA8CL-2TC14E1
68
YA8CL-2TC14E1-45
68
YA8CL-2TC14E1-90
68
YA8CL-2TC14E2
68
YA8CL-2TC14E2-45
68
YA8CL-2TC14E2-90
68
YA8CL-2TC38
68
YA8CL-2TC38-45
68
YA8CL-2TC38-90
68
YA8CL-45
34
YA8CL-45
50
YA8CL-90
34
YA8CL-90
50
YA8CL-BOX
34
YA8CL-BOX
50
YA8CL1-45
34
YA8CL1-90
34
YA8CL1-BOX
34
YA8CL2-45
34
YA8CL2-90
34
YA8CL2-BOX
34
YA8CL2TC10
89
YA8CL2TC10-45
89
YA8CL2TC10-90
89
YA8CL2TC14
89
YA8CL2TC14-45
89
YA8CL2TC14-90
89
YA8CL2TC14E1
89
YA8CL2TC14E1-45
89
YA8CL2TC14E1-90
89

CATALOG NO.
PAGE NO.
YA8CL2TC14E2
89
YA8CL2TC14E2-45
89
YA8CL2TC14E2-90
89
YA8CL2TC38
89
YA8CL2TC38-45
89
YA8CL2TC38-90
89
YA8CL3-45
34
YA8CL3-90
34
YA8CL3-BOX
34
YA8CL4-45
34
YA8CL4-90
34
YA8CL4-BOX
34
YA8CLNT6
40
YAE10N
5
YAE10N BOX
5
YAE10N11
5
YAE10N11 BOX
5
YAE10N11M
5
YAE10N2
5
YAE10N2 BOX
5
YAE10N2M
5
YAE10N3
5
YAE10N3 BOX
5
YAE10N3M
5
YAE10N4
5
YAE10N4 BOX
5
YAE10N4M
5
YAE10N5
5
YAE10N5 BOX
5
YAE10N5M
5
YAE10NM
5
YAE12N
5
YAE12N BOX
5
YAE12N1
5
YAE12N1 BOX
5
YAE12N1M
5
YAE12N2
5
YAE12N2 BOX
5
YAE12N2M
5
YAE12N7
5
YAE12N7 BOX
5
YAE12N7M
5
YAE12N9
5
YAE12N9 BOX
5
YAE12N9M
5
YAE12NM
5
YAE12Z2
21
YAE12Z2 BOX
21
YAE12Z2M
21
YAE12Z3
21
YAE12Z3 BOX
21
YAE12Z3M
21
YAE12Z4
21
YAE12Z4 BOX
21
YAE12Z4M
21
YAE14N
5
YAE14N BOX
5
YAE14N1
5
YAE14N1 BOX
5
YAE14N1M
5
YAE14N2
5
YAE14N2 BOX
5
YAE14N2M
5
YAE14N3
5
YAE14N3 BOX
5
YAE14N3M
5
YAE14N4
5
YAE14N4 BOX
5
YAE14N43
5
YAE14N43 BOX
5
YAE14N43M
5
YAE14N4M
5
YAE14N52
3
YAE14N76F
20
YAE14N76F BOX
20
YAE14N76FM
20

CATALOG NO.
YAE14N77F
YAE14N77F BOX
YAE14N77FM
YAE14N78F
YAE14N78F BOX
YAE14N78FM
YAE14NM
YAE14Z2
YAE14Z2 BOX
YAE14Z2M
YAE14Z3
YAE14Z3 BOX
YAE14Z3M
YAE14Z4
YAE14Z4 BOX
YAE14Z4M
YAE18-N7
YAE18-N7M
YAE18G43
YAE18G43 BOX
YAE18G43F
YAE18G43F BOX
YAE18G43FM
YAE18G43M
YAE18G60FM
YAE18N
YAE18N BOX
YAE18N1
YAE18N1 BOX
YAE18N17
YAE18N17 BOX
YAE18N17M
YAE18N1M
YAE18N2
YAE18N2 BOX
YAE18N21
YAE18N21 BOX
YAE18N21M
YAE18N24
YAE18N24 BOX
YAE18N24M
YAE18N25
YAE18N25 BOX
YAE18N25M
YAE18N26
YAE18N26 BOX
YAE18N26M
YAE18N27
YAE18N27 BOX
YAE18N27M
YAE18N29
YAE18N29 BOX
YAE18N29M
YAE18N2M
YAE18N3
YAE18N3 BOX
YAE18N3M
YAE18N56F
YAE18N56F BOX
YAE18N56FM
YAE18N57F
YAE18N57F BOX
YAE18N57FM
YAE18N60F
YAE18N60F BOX
YAE18N7 BOX
YAE18NM
YAE18Z1
YAE18Z1 BOX
YAE18Z1M
YAE18Z2
YAE18Z2 BOX
YAE18Z2M
YAE18Z3
YAE18Z3 BOX
YAE18Z3M

PAGE NO.
20
20
20
20
20
20
5
21
21
21
21
21
21
21
21
21
5
5
5
5
20
20
20
5
20
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
20
20
20
20
20
20
20
20
5
5
21
21
21
21
21
21
21
21
21

225

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YAE18Z4
21
YAE18Z4 BOX
21
YAE18Z4M
21
YAE22G12
4
YAE22G12 BOX
4
YAE22G12M
4
YAE22G13
4
YAE22G13 BOX
4
YAE22G13M
4
YAE22G14
4
YAE22G14 BOX
4
YAE22G14M
4
YAE22G15
4
YAE22G15 BOX
4
YAE22G15M
4
YAE22G16
4
YAE22G16 BOX
4
YAE22G16M
4
YAE22G18
4
YAE22G18 BOX
4
YAE22G18M
4
YAE22N65F
20
YAE22N65F BOX
20
YAE22N65FM
20
YAE22N66F
20
YAE22N66F BOX
20
YAE22N66FM
20
YAE22Z1
21
YAE22Z1 BOX
21
YAE22Z1M
21
YAE22Z2
21
YAE22Z2 BOX
21
YAE22Z2M
21
YAE22Z3
21
YAE22Z3 BOX
21
YAE22Z3M
21
YAES10N11
3
YAES10N11F
19
YAES10N12
3
YAES10N12F
19
YAES10N13
3
YAES10N14
3
YAES10N56
3
YAES10N56F
19
YAES10N57
3
YAES10N57F
19
YAES14N10
3
YAES14N53
3
YAES14N53F
19
YAES14N54
3
YAES14N54F
19
YAES14N6
3
YAES14N6F
19
YAES14N8
3
YAES14N8F
19
YAES14N9
3
YAES18N1
3
YAES18N1F
19
YAES18N3
3
YAES18N3F
19
YAES18N4
3
YAES18N48
3
YAES18N49
3
YAES18N49F
19
YAES18N5
3
YAES18N50
3
YAES18N50F
19
YAEV10
6
YAEV10 BOX
6
YAEV10-L36
6
YAEV10-L36 BOX
6
YAEV10-T11
6
YAEV10-T11 BOX
6
YAEV10-T2
6
YAEV10-T2 BOX
6
YAEV10-T3
6

226

CATALOG NO.
YAEV10-T3 BOX
YAEV10-T4
YAEV10-T4 BOX
YAEV10-T7
YAEV10-T7 BOX
YAEV14
YAEV14 BOX
YAEV18
YAEV18 BOX
YAEV1C-H
YAEV1C-H1
YAEV1C-H2
YAEV1C-H3
YAEV1C-L
YAEV1C-L1
YAEV1C-L2
YAEV1C-L3
YAEV1C-RH
YAEV1C-RH2
YAEV1C-RS
YAEV1C-RS2
YAEV25-H
YAEV25-H1
YAEV25-H2
YAEV25-H3
YAEV25-H4
YAEV25-L
YAEV25-L1
YAEV25-L2
YAEV25-L3
YAEV25-L4
YAEV25-RH
YAEV25-RS
YAEV26-H
YAEV26-H1
YAEV26-H12
YAEV26-H2
YAEV26-H3
YAEV26-L
YAEV26-L1
YAEV26-L12
YAEV26-L2
YAEV26-L3
YAEV26-RH
YAEV26-RS
YAEV2C-H
YAEV2C-H1
YAEV2C-H2
YAEV2C-H3
YAEV2C-H4
YAEV2C-L
YAEV2C-L1
YAEV2C-L2
YAEV2C-L3
YAEV2C-L4
YAEV2C-RH
YAEV2C-RH1
YAEV2C-RS
YAEV2C-RS1
YAEV4C-H
YAEV4C-H2
YAEV4C-H3
YAEV4C-H4
YAEV4C-H5
YAEV4C-L
YAEV4C-L2
YAEV4C-L3
YAEV4C-L4
YAEV4C-L5
YAEV4C-RH
YAEV4C-RH2
YAEV4C-RS
YAEV4C-RS2
YAEV6C-H
YAEV6C-H1
YAEV6C-H10

PAGE NO.
6
6
6
6
6
6
6
6
6
9
9
9
9
7
7
7
7
11
11
8
8
10
10
10
10
10
7
7
7
7
7
11
8
10
10
10
10
10
7
7
7
7
7
11
8
9
9
9
9
9
7
7
7
7
7
11
11
8
8
9
9
9
9
9
7
7
7
7
7
11
11
8
8
9
9
9

CATALOG NO.
PAGE NO.
YAEV6C-H2
9
YAEV6C-H4
9
YAEV6C-L
7
YAEV6C-L1
7
YAEV6C-L10
7
YAEV6C-L2
7
YAEV6C-L4
7
YAEV6C-RH
11
YAEV6C-RH1
11
YAEV6C-RS
8
YAEV6C-RS1
8
YAEV8-L1
7
YAEV8C-H
9
YAEV8C-H1
9
YAEV8C-H14
9
YAEV8C-H2
9
YAEV8C-H3
9
YAEV8C-H4
9
YAEV8C-L
7
YAEV8C-L BOX
7
YAEV8C-L1 BOX
7
YAEV8C-L14
7
YAEV8C-L14 BOX
7
YAEV8C-L2
7
YAEV8C-L2 BOX
7
YAEV8C-L3
7
YAEV8C-L3 BOX
7
YAEV8C-L4
7
YAEV8C-L4 BOX
7
YAEV8C-RH
11
YAEV8C-RH1
11
YAEV8C-RS
8
YAEV8C-RS1
8
YAG18TC516LD
57
YAG1CL-2NTC-LD
98
YAG1CL-2NTC-LD-45
98
YAG1CL-2NTC-LD-90
98
YAG1CL-2TC14-LD
98
YAG1CL-2TC14-LD-45
98
YAG1CL-2TC14-LD-90
98
YAG1CL-2TC14E1-LD
98
YAG1CL-2TC14E1-LD-45 98
YAG1CL-2TC14E1-LD-90 98
YAG1CL-2TC14E2-LD
98
YAG1CL-2TC14E2-LD-45 98
YAG1CL-2TC14E2-LD-90 98
YAG1CL-2TC38-LD
98
YAG1CL-2TC38-LD-45
98
YAG1CL-2TC38-LD-90
98
YAG1CL-2TC516-LD
98
YAG1CL-2TC516-LD-45
98
YAG1CL-2TC516-LD-90
98
YAG1CLTC10LD
58
YAG1CLTC10LD45
58
YAG1CLTC10LD90
58
YAG1CLTC12LD
58
YAG1CLTC12LD45
58
YAG1CLTC12LD90
58
YAG1CLTC14LD
58
YAG1CLTC14LD45
58
YAG1CLTC14LD90
58
YAG1CLTC38LD
58
YAG1CLTC38LD45
58
YAG1CLTC38LD90
58
YAG1CLTC516LD
58
YAG1CLTC516LD45
58
YAG1CLTC516LD90
58
YAG25L-2NTC-LD
98
YAG25L-2NTC-LD-45
98
YAG25L-2NTC-LD-90
98
YAG25L-2TC12E1-LD
98
YAG25L-2TC12E1-LD-45 98
YAG25L-2TC12E1-LD-90 98
YAG25L-2TC14-LD
98
YAG25L-2TC14-LD-45
98
YAG25L-2TC14-LD-90
98

CATALOG NO.
PAGE NO.
YAG25L-2TC14E2-LD
98
YAG25L-2TC14E2-LD-45 98
YAG25L-2TC14E2-LD-90 98
YAG25L-2TC38-LD
98
YAG25L-2TC38-LD-45
98
YAG25L-2TC38-LD-90
98
YAG25L-2TC516-LD
98
YAG25L-2TC516-LD-45
98
YAG25L-2TC516-LD-90
98
YAG25L-2TC516E2-LD
98
YAG25L-2TC516E2-LD-45 98
YAG25L-2TC516E2-LD-90 98
YAG25LTC12LD
59
YAG25LTC12LD45
59
YAG25LTC12LD90
59
YAG25LTC14LD
59
YAG25LTC14LD45
59
YAG25LTC14LD90
59
YAG25LTC38LD
59
YAG25LTC38LD45
59
YAG25LTC38LD90
59
YAG25LTC516LD
59
YAG25LTC516LD45
59
YAG25LTC516LD90
59
YAG26L-2NTC-LD
99
YAG26L-2NTC-LD-45
99
YAG26L-2NTC-LD-90
99
YAG26L-2TC14-LD
98
YAG26L-2TC14-LD-45
98
YAG26L-2TC14-LD-90
98
YAG26L-2TC14E2-LD
99
YAG26L-2TC14E2-LD-45 99
YAG26L-2TC14E2-LD-90 99
YAG26L-2TC38-LD
99
YAG26L-2TC38-LD-45
99
YAG26L-2TC38-LD-90
99
YAG26L-2TC516-LD
99
YAG26L-2TC516-LD-45
99
YAG26L-2TC516-LD-90
99
YAG26LTC10LD
59
YAG26LTC10LD45
59
YAG26LTC10LD90
59
YAG26LTC12LD
59
YAG26LTC12LD45
59
YAG26LTC12LD90
59
YAG26LTC14LD
59
YAG26LTC14LD45
59
YAG26LTC14LD90
59
YAG26LTC34LD
59
YAG26LTC34LD45
59
YAG26LTC34LD90
59
YAG26LTC38LD
59
YAG26LTC38LD45
59
YAG26LTC38LD90
59
YAG26LTC516LD
59
YAG26LTC516LD45
59
YAG26LTC516LD90
59
YAG26LTC58LD
59
YAG26LTC58LD45
59
YAG26LTC58LD90
59
YAG27L-2NTC-LD
99
YAG27L-2NTC-LD-45
99
YAG27L-2NTC-LD-90
99
YAG27L-2TC14-LD
99
YAG27L-2TC14-LD-45
99
YAG27L-2TC14-LD-90
99
YAG27L-2TC14E2-LD
99
YAG27L-2TC14E2-LD-45 99
YAG27L-2TC14E2-LD-90 99
YAG27L-2TC38-LD
99
YAG27L-2TC38-LD-45
99
YAG27L-2TC38-LD-90
99
YAG27L-2TC516-LD
99
YAG27L-2TC516-LD-45
99
YAG27L-2TC516-LD-90
99
YAG27LTC10LD
59

CATALOG NO.
PAGE NO.
YAG27LTC10LD45
59
YAG27LTC10LD90
59
YAG27LTC12LD
59
YAG27LTC12LD45
59
YAG27LTC12LD90
59
YAG27LTC14LD
59
YAG27LTC14LD45
59
YAG27LTC14LD90
59
YAG27LTC38LD
59
YAG27LTC38LD45
59
YAG27LTC38LD90
59
YAG27LTC516LD
59
YAG27LTC516LD45
59
YAG27LTC516LD90
59
YAG28L-2NT38-LD
99
YAG28L-2NT38-LD-45
99
YAG28L-2NT38-LD-90
99
YAG28L-2NTC-LD
100
YAG28L-2NTC-LD-45
100
YAG28L-2NTC-LD-90
100
YAG28L-2TC12-LD
99
YAG28L-2TC12-LD-45
99
YAG28L-2TC12-LD-90
99
YAG28L-2TC12E1-LD
99
YAG28L-2TC12E1-LD-45 99
YAG28L-2TC12E1-LD-90 99
YAG28L-2TC14-LD
99
YAG28L-2TC14-LD-45
99
YAG28L-2TC14-LD-90
99
YAG28L-2TC14E2-LD
99
YAG28L-2TC14E2-LD-45 99
YAG28L-2TC14E2-LD-90 99
YAG28L-2TC38-LD
99
YAG28L-2TC38-LD-45
99
YAG28L-2TC38-LD-90
99
YAG28L-2TC516-LD
99
YAG28L-2TC516-LD-45
99
YAG28L-2TC516-LD-90
99
YAG28LTC12LD
60
YAG28LTC12LD45
60
YAG28LTC12LD90
60
YAG28LTC14LD
60
YAG28LTC14LD45
60
YAG28LTC14LD90
60
YAG28LTC34LD
60
YAG28LTC34LD45
60
YAG28LTC34LD90
60
YAG28LTC38LD
60
YAG28LTC38LD45
60
YAG28LTC38LD90
60
YAG28LTC516LD
60
YAG28LTC516LD45
60
YAG28LTC516LD90
60
YAG28LTC516N66LD
60
YAG28LTC58LD
60
YAG28LTC58LD45
60
YAG28LTC58LD90
60
YAG29L-2NT38-LD
100
YAG29L-2NT38-LD-45
100
YAG29L-2NT38-LD-90
100
YAG29L-2NTC-LD
100
YAG29L-2NTC-LD-45
100
YAG29L-2NTC-LD-90
100
YAG29L-2TC12-LD
100
YAG29L-2TC12-LD-45
100
YAG29L-2TC12-LD-90
100
YAG29L-2TC12E1-LD
100
YAG29L-2TC12E1-LD-45 100
YAG29L-2TC12E1-LD-90 100
YAG29L-2TC14-LD
100
YAG29L-2TC14-LD-45
100
YAG29L-2TC14-LD-90
100
YAG29L-2TC14E2-LD
100
YAG29L-2TC14E2-LD-45 100
YAG29L-2TC14E2-LD-90 100
YAG29L-2TC38-LD
100

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YAG29L-2TC38-LD-45
100
YAG29L-2TC38-LD-90
100
YAG29L-2TC516-LD
100
YAG29L-2TC516-LD-45 100
YAG29L-2TC516-LD-90 100
YAG29LTC12LD
60
YAG29LTC12LD45
60
YAG29LTC12LD90
60
YAG29LTC14LD
60
YAG29LTC14LD45
60
YAG29LTC14LD90
60
YAG29LTC34LD
60
YAG29LTC34LD45
60
YAG29LTC34LD90
60
YAG29LTC38LD
60
YAG29LTC38LD45
60
YAG29LTC38LD90
60
YAG29LTC516LD
60
YAG29LTC516LD45
60
YAG29LTC516LD90
60
YAG29LTC58LD
60
YAG29LTC58LD45
60
YAG29LTC58LD90
60
YAG2CL-2NTC-LD
98
YAG2CL-2NTC-LD-45
98
YAG2CL-2NTC-LD-90
98
YAG2CL-2TC14-LD
97
YAG2CL-2TC14-LD-45
97
YAG2CL-2TC14-LD-90
97
YAG2CL-2TC14E1-LD
97
YAG2CL-2TC14E1-LD-45 97
YAG2CL-2TC14E1-LD-90 97
YAG2CL-2TC14E2-LD
97
YAG2CL-2TC14E2-LD-45 97
YAG2CL-2TC14E2-LD-90 97
YAG2CL-2TC38-LD
97
YAG2CL-2TC38-LD-45
97
YAG2CL-2TC38-LD-90
97
YAG2CL-2TC516-LD
98
YAG2CL-2TC516-LD-45
98
YAG2CL-2TC516-LD-90
98
YAG2CLTC10LD
58
YAG2CLTC10LD45
58
YAG2CLTC10LD90
58
YAG2CLTC12LD
58
YAG2CLTC12LD45
58
YAG2CLTC12LD90
58
YAG2CLTC14LD
58
YAG2CLTC14LD45
58
YAG2CLTC14LD90
58
YAG2CLTC38LD
58
YAG2CLTC38LD45
58
YAG2CLTC38LD90
58
YAG2CLTC516LD
58
YAG2CLTC516LD45
58
YAG2CLTC516LD90
58
YAG30L-2NTC-LD
100
YAG30L-2NTC-LD-45
100
YAG30L-2TC12-LD
100
YAG30L-2TC12-LD-45
100
YAG30L-2TC12-LD-90
100
YAG30L-2TC38-LD
100
YAG30L-2TC38-LD-45
100
YAG30L-2TC38-LD-90
100
YAG30LTC12LD
60
YAG30LTC12LD45
60
YAG30LTC12LD90
60
YAG30LTC34LD
61
YAG30LTC34LD45
61
YAG30LTC34LD90
61
YAG30LTC38LD
60
YAG30LTC38LD45
60
YAG30LTC38LD90
60
YAG30LTC516LD
60
YAG30LTC516LD45
60
YAG30LTC516LD90
60

CATALOG NO.
PAGE NO.
YAG30LTC58LD
61
YAG30LTC58LD45
61
YAG30LTC58LD90
61
YAG31L-2NTC-LD
100
YAG31L-2NTC-LD-45
100
YAG31L-2NTC-LD-90
100
YAG31L-2NTC38-LD
100
YAG31L-2NTC38-LD-45 100
YAG31L-2NTC38-LD-90 100
YAG31L-2TC12-LD
100
YAG31L-2TC12-LD-45
100
YAG31L-2TC12-LD-90
100
YAG31L-2TC38-LD
100
YAG31L-2TC38-LD-45
100
YAG31L-2TC38-LD-90
100
YAG31LNT12LD
61
YAG31LNT12LD45
61
YAG31LNT12LD90
61
YAG31LTC12LD
61
YAG31LTC12LD45
61
YAG31LTC12LD90
61
YAG31LTC14LD
61
YAG31LTC14LD45
61
YAG31LTC14LD90
61
YAG31LTC34LD
61
YAG31LTC34LD45
61
YAG31LTC34LD90
61
YAG31LTC38LD
61
YAG31LTC38LD45
61
YAG31LTC38LD90
61
YAG31LTC516LD
61
YAG31LTC516LD45
61
YAG31LTC516LD90
61
YAG31LTC58LD
61
YAG31LTC58LD45
61
YAG31LTC58LD90
61
YAG32L-2NTC-LD
101
YAG32L-2NTC-LD-45
101
YAG32L-2NTC-LD-90
101
YAG32L-2TC38-LD
101
YAG32L-2TC38-LD-45
101
YAG32L-2TC38-LD-90
101
YAG32LTC12LD
61
YAG32LTC12LD45
61
YAG32LTC12LD90
61
YAG32LTC38LD
61
YAG32LTC38LD45
61
YAG32LTC38LD90
61
YAG32LTC58LD
61
YAG32LTC58LD45
61
YAG32LTC58LD90
61
YAG34L-2NT38-LD
101
YAG34L-2NT38-LD-45
101
YAG34L-2NT38-LD-90
101
YAG34L-2NTC-LD
101
YAG34L-2NTC-LD-45
101
YAG34L-2NTC-LD-90
101
YAG34L-2TC12-LD
101
YAG34L-2TC12-LD-45
101
YAG34L-2TC12-LD-90
101
YAG34L-2TC38-LD
101
YAG34L-2TC38-LD-45
101
YAG34L-2TC38-LD-90
101
YAG34L-2TC516-LD
101
YAG34L-2TC516-LD-45 101
YAG34L-2TC516-LD-90 101
YAG34LNT516N66LD
61
YAG34LTC12LD
61
YAG34LTC12LD45
61
YAG34LTC12LD90
61
YAG34LTC38LD
61
YAG34LTC38LD45
61
YAG34LTC38LD90
61
YAG34LTC516LD
61
YAG34LTC516LD45
61
YAG34LTC516LD90
61

CATALOG NO.
PAGE NO.
YAG34LTC516N66LD
61
YAG34LTC58LD
62
YAG34LTC58LD45
62
YAG34LTC58LD90
62
YAG36L-2NTC-LD
101
YAG36L-2NTC-LD-45
101
YAG36L-2NTC-LD-90
101
YAG36L-2TC38-LD
101
YAG36L-2TC38-LD-45
101
YAG36L-2TC38-LD-90
101
YAG36LTC12LD
62
YAG36LTC12LD45
62
YAG36LTC12LD90
62
YAG36LTC58LD
62
YAG36LTC58LD45
62
YAG36LTC58LD90
62
YAG38L-2NT38-LD
101
YAG38L-2NT38-LD-45
101
YAG38L-2NT38-LD-90
101
YAG38L-2NTC-LD
101
YAG38L-2NTC-LD-45
101
YAG38L-2NTC-LD-90
101
YAG38L-2TC12-LD
101
YAG38L-2TC12-LD-45
101
YAG38L-2TC12-LD-90
101
YAG38L-2TC38-LD
101
YAG38L-2TC38-LD-45
101
YAG38L-2TC38-LD-90
101
YAG38L-2TC516-LD
101
YAG38L-2TC516-LD-45 101
YAG38L-2TC516-LD-90 101
YAG38LTC12LD
62
YAG38LTC12LD45
62
YAG38LTC12LD90
62
YAG38LTC38LD
62
YAG38LTC38LD45
62
YAG38LTC38LD90
62
YAG38LTC516LD
62
YAG38LTC516LD45
62
YAG38LTC516LD90
62
YAG38LTC58LD
62
YAG38LTC58LD45
62
YAG38LTC58LD90
62
YAG39L-2NTC-LD
101
YAG39L-2NTC-LD-45
101
YAG39L-2NTC-LD-90
101
YAG40L-2NNT-LD
102
YAG40L-2NNT-LD-45
102
YAG40L-2NNT-LD-90
102
YAG40L-2NTC-LD
102
YAG40L-2NTC-LD-45
102
YAG40L-2NTC-LD-90
102
YAG40L-2TC38-LD
101
YAG40L-2TC38-LD-45
101
YAG40L-2TC38-LD-90
101
YAG40LTC12LD
62
YAG40LTC12LD45
62
YAG40LTC12LD90
62
YAG40LTC38LD
62
YAG40LTC38LD45
62
YAG40LTC38LD90
62
YAG40LTC516LD
62
YAG40LTC516LD45
62
YAG40LTC516LD90
62
YAG40LTC58LD
62
YAG40LTC58LD45
62
YAG40LTC58LD90
62
YAG44L-2NTC-LD
102
YAG44L-2NTC-LD-45
102
YAG44L-2NTC-LD-90
102
YAG44L-2TC12-LD
102
YAG44L-2TC12-LD-45
102
YAG44L-2TC12-LD-90
102
YAG44L-2TC12E3-LD
102
YAG44L-2TC12E3-LD-45 102
YAG44L-2TC12E3-LD-90 102

CATALOG NO.
PAGE NO.
YAG44L-2TC38-LD
102
YAG44L-2TC38-LD-45
102
YAG44L-2TC38-LD-90
102
YAG44L-2TC58-LD
102
YAG44L-2TC58-LD-45
102
YAG44L-2TC58-LD-90
102
YAG44LTC12LD
62
YAG44LTC12LD45
62
YAG44LTC12LD90
62
YAG44LTC58LD
62
YAG44LTC58LD45
62
YAG44LTC58LD90
62
YAG4CL-2NT10-LD
97
YAG4CL-2NT10-LD-45
97
YAG4CL-2NT10-LD-90
97
YAG4CL-2NT10E1-LD
97
YAG4CL-2NT10E1-LD-45 97
YAG4CL-2NT10E1-LD-90 97
YAG4CL-2NTC-LD
97
YAG4CL-2NTC-LD-45
97
YAG4CL-2NTC-LD-90
97
YAG4CL-2TC14-LD
97
YAG4CL-2TC14-LD-45
97
YAG4CL-2TC14-LD-90
97
YAG4CL-2TC14E1-LD
97
YAG4CL-2TC14E1-LD-45 97
YAG4CL-2TC14E1-LD-90 97
YAG4CL-2TC14E2-LD
97
YAG4CL-2TC14E2-LD-45 97
YAG4CL-2TC14E2-LD-90 97
YAG4CL-2TC38-LD
97
YAG4CL-2TC38-LD-45
97
YAG4CL-2TC38-LD-90
97
YAG4CL-2TC516-LD
97
YAG4CL-2TC516-LD-45
97
YAG4CL-2TC516-LD-90
97
YAG4CLNT10LD
58
YAG4CLNT10LD45
58
YAG4CLNT10LD90
58
YAG4CLTC10LD
58
YAG4CLTC10LD45
58
YAG4CLTC10LD90
58
YAG4CLTC12LD
58
YAG4CLTC12LD45
58
YAG4CLTC12LD90
58
YAG4CLTC14LD
58
YAG4CLTC14LD45
58
YAG4CLTC14LD90
58
YAG4CLTC38LD
58
YAG4CLTC38LD45
58
YAG4CLTC38LD90
58
YAG4CLTC516LD
58
YAG4CLTC516LD45
58
YAG4CLTC516LD90
58
YAG6CL-2NTC-LD
97
YAG6CL-2NTC-LD-45
97
YAG6CL-2NTC-LD-90
97
YAG6CL-2TC10-LD
96
YAG6CL-2TC10-LD-45
96
YAG6CL-2TC10-LD-90
96
YAG6CL-2TC10E-LD
96
YAG6CL-2TC10E-LD-45
96
YAG6CL-2TC10E-LD-90
96
YAG6CL-2TC10E2-LD
96
YAG6CL-2TC10E2-LD-45 96
YAG6CL-2TC10E2-LD-90 96
YAG6CL-2TC10E4-LD
96
YAG6CL-2TC10E4-LD-45 96
YAG6CL-2TC10E4-LD-90 96
YAG6CL-2TC14-LD
96
YAG6CL-2TC14-LD-45
96
YAG6CL-2TC14-LD-90
96
YAG6CL-2TC14E1-LD
96
YAG6CL-2TC14E1-LD-45 96
YAG6CL-2TC14E1-LD-90 96
YAG6CL-2TC14E2-LD
97

CATALOG NO.
PAGE NO.
YAG6CL-2TC14E2-LD-45 97
YAG6CL-2TC14E2-LD-90 97
YAG6CL-2TC38-LD
97
YAG6CL-2TC38-LD-45
97
YAG6CL-2TC38-LD-90
97
YAG6CL-2TC516-LD
97
YAG6CL-2TC516-LD-45
97
YAG6CL-2TC516-LD-90
97
YAG6CLTC10LD
57
YAG6CLTC10LD45
57
YAG6CLTC10LD90
57
YAG6CLTC12LD
57
YAG6CLTC12LD45
57
YAG6CLTC12LD90
57
YAG6CLTC14LD
57
YAG6CLTC14LD45
57
YAG6CLTC14LD90
57
YAG6CLTC38LD
57
YAG6CLTC38LD45
57
YAG6CLTC38LD90
57
YAG6CLTC516LD
57
YAG6CLTC516LD45
57
YAG6CLTC516LD90
57
YAG8CL-2TC10-LD
96
YAG8CL-2TC10-LD-45
96
YAG8CL-2TC10-LD-90
96
YAG8CL-2TC14-LD
96
YAG8CL-2TC14-LD-45
96
YAG8CL-2TC14-LD-90
96
YAG8CL-2TC14E1-LD
96
YAG8CL-2TC14E1-LD-45 96
YAG8CL-2TC14E1-LD-90 96
YAG8CL-2TC14E2-LD
96
YAG8CL-2TC14E2-LD-45 96
YAG8CL-2TC14E2-LD-90 96
YAG8CL-2TC38-LD
96
YAG8CL-2TC38-LD-45
96
YAG8CL-2TC38-LD-90
96
YAG8CLTC10LD
57
YAG8CLTC10LD45
57
YAG8CLTC10LD90
57
YAG8CLTC12LD
57
YAG8CLTC12LD45
57
YAG8CLTC12LD90
57
YAG8CLTC14LD
57
YAG8CLTC14LD45
57
YAG8CLTC14LD90
57
YAG8CLTC38LD
57
YAG8CLTC38LD45
57
YAG8CLTC38LD90
57
YAG8CLTC516LD
57
YAG8CLTC516LD45
57
YAG8CLTC516LD90
57
YASG6CL-2TC14E2-FX 110
YASG6CL-2TC14E2-FX-60 110
YASG8CL-2TC14E2-FX 110
YASG8CL-2TC14E2-FX-60 110
YASV6CL-2TC14E2-FX 110
YASV6CL-2TC14E2-FX-60 110
YAV10
12
YAV10 BOX
12
YAV10-45-BOX
34
YAV10-BOX
34
YAV10-HF
22
YAV10-HF BOX
22
YAV10-L36
12
YAV10-L36 BOX
12
YAV10-R
15
YAV10-R3 BOX
15
YAV10-T11
12
YAV10-T11 BOX
12
YAV10-T2
12
YAV10-T2 BOX
12
YAV10-T3
12
YAV10-T3 BOX
12
YAV10-T4
12

227

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YAV10-T4 BOX
12
YAV10-T7
12
YAV10-T7 BOX
12
YAV102TC10
68
YAV102TC10-45
68
YAV102TC10-90
68
YAV102TC14
68
YAV102TC14-45
68
YAV102TC14-90
68
YAV102TC14E1
68
YAV102TC14E2
68
YAV102TC38
68
YAV102TC38-45
68
YAV102TC38-90
68
YAV10R-BOX
34
YAV10R3-BOX
34
YAV10T2-BOX
34
YAV10T3-45-BOX
34
YAV10T3-BOX
34
YAV10T4-BOX
34
YAV12-G2
12
YAV12-G2 BOX
12
YAV12-G3
12
YAV12-G3 BOX
12
YAV14
12
YAV14 BOX
12
YAV14-H32F
22
YAV14-H32F BOX
22
YAV14-H34F
22
YAV14-H34F BOX
22
YAV14-H56F
22
YAV14-H56F BOX
22
YAV14-HF
22
YAV14-HF BOX
22
YAV14-L33
12
YAV14-L33 BOX
12
YAV14-L36
12
YAV14-L36 BOX
12
YAV14-R
15
YAV14-RL33
15
YAV14-T1
12
YAV14-T1 BOX
12
YAV14-T2
12
YAV14-T2 BOX
12
YAV14-T3
12
YAV14-T3 BOX
12
YAV14-T5
12
YAV14-T5 BOX
12
YAV14-Z5
22
YAV14-Z5 BOX
22
YAV14-Z6
22
YAV14-Z6 BOX
22
YAV18
12
YAV18 BOX
12
YAV18-H19 BOX
22
YAV18-H19F
22
YAV18-H21F
22
YAV18-H21F BOX
22
YAV18-H6F
22
YAV18-H6F BOX
22
YAV18-L33
12
YAV18-L33 BOX
12
YAV18-R
15
YAV18-T1
12
YAV18-T1 BOX
12
YAV18-T4
12
YAV18-T4 BOX
12
YAV18-T5
12
YAV18-T5 BOX
12
YAV1C-L
14
YAV1C-L BOX
14
YAV1C-L1
14
YAV1C-L1 BOX
14
YAV1C-L2
14
YAV1C-L2 BOX
14
YAV1C-L2NTC-FX
91

228

CATALOG NO.
PAGE NO.
YAV1C-L2NTC-FX-45
91
YAV1C-L2NTC-FX-90
91
YAV1C-L2TC14-FX
91
YAV1C-L2TC14-FX-45
91
YAV1C-L2TC14-FX-90
91
YAV1C-L2TC14E1-FX
91
YAV1C-L2TC14E1-FX-45 91
YAV1C-L2TC14E1-FX-90 91
YAV1C-L2TC14E2-FX
91
YAV1C-L2TC14E2-FX-45 91
YAV1C-L2TC14E2-FX-90 91
YAV1C-L2TC38-FX
91
YAV1C-L2TC38-FX-45
91
YAV1C-L2TC38-FX-90
91
YAV1C-L2TC516-FX
91
YAV1C-L2TC516-FX-45
91
YAV1C-L2TC516-FX-90
91
YAV1C-L3
14
YAV1C-L3 BOX
14
YAV1C-L6
14
YAV1C-RS1
15
YAV1C-RS2
15
YAV1C-TC10-FXB
63
YAV1C-TC516-FXB
63
YAV1C2N-FXB
103
YAV1C2TC14-FXB
103
YAV1C2TC14E2-FXB
103
YAV1C2TC38-FXB
103
YAV1CL-TC10-FX
51
YAV1CL-TC10-FX-45
51
YAV1CL-TC10-FX-90
51
YAV1CL-TC12-FX
51
YAV1CL-TC12-FX-45
51
YAV1CL-TC12-FX-90
51
YAV1CL-TC14-FX
51
YAV1CL-TC14-FX-45
51
YAV1CL-TC14-FX-90
51
YAV1CL-TC38-FX
51
YAV1CL-TC38-FX-45
51
YAV1CL-TC38-FX-90
51
YAV1CL-TC516-FX
51
YAV1CL-TC516-FX-45
51
YAV1CL-TC516-FX-90
51
YAV25-L
14
YAV25-L BOX
14
YAV25-L1
14
YAV25-L1 BOX
14
YAV25-L2
14
YAV25-L2 BOX
14
YAV25-L2NTC-FX
92
YAV25-L2NTC-FX-45
92
YAV25-L2NTC-FX-90
92
YAV25-L2TC12E1-FX
91
YAV25-L2TC12E1-FX-45 91
YAV25-L2TC12E1-FX-90 91
YAV25-L2TC14-FX
91
YAV25-L2TC14-FX-45
91
YAV25-L2TC14-FX-90
91
YAV25-L2TC14E2-FX
91
YAV25-L2TC14E2-FX-45 91
YAV25-L2TC14E2-FX-90 91
YAV25-L2TC38-FX
91
YAV25-L2TC38-FX-45
91
YAV25-L2TC38-FX-90
91
YAV25-L2TC516-FX
91
YAV25-L2TC516-FX-45
91
YAV25-L2TC516-FX-90
91
YAV25-L2TC516E2-FX
91
YAV25-L2TC516E2-FX-45 91
YAV25-L2TC516E2-FX-90 91
YAV25-L3
14
YAV25-L3 BOX
14
YAV25-L4
14
YAV25-L4 BOX
14
YAV25-RS
15
YAV25-RS3
15

CATALOG NO.
PAGE NO.
YAV25-TC10-FXB
63
YAV25-TC12-FXB
63
YAV25-TC38-FXB
63
YAV25-TC516-FXB
63
YAV252N-FXB
104
YAV252TC14-FXB
103
YAV252TC14E2-FXB
103
YAV252TC38-FXB
103
YAV25L-TC12-FX
52
YAV25L-TC12-FX-45
52
YAV25L-TC12-FX-90
52
YAV25L-TC14-FX
52
YAV25L-TC14-FX-45
52
YAV25L-TC14-FX-90
52
YAV25L-TC38-FX
52
YAV25L-TC38-FX-45
52
YAV25L-TC38-FX-90
52
YAV25L-TC516-FX
52
YAV25L-TC516-FX-45
52
YAV25L-TC516-FX-90
52
YAV26-L
14
YAV26-L BOX
14
YAV26-L1
14
YAV26-L1 BOX
14
YAV26-L12
14
YAV26-L12 BOX
14
YAV26-L2
14
YAV26-L2 BOX
14
YAV26-L2NTC-FX
92
YAV26-L2NTC-FX-45
92
YAV26-L2NTC-FX-90
92
YAV26-L2TC12E1-FX
92
YAV26-L2TC12E1-FX-45 92
YAV26-L2TC12E1-FX-90 92
YAV26-L2TC14-FX
92
YAV26-L2TC14-FX-45
92
YAV26-L2TC14-FX-90
92
YAV26-L2TC14E2-FX
92
YAV26-L2TC14E2-FX-45 92
YAV26-L2TC14E2-FX-90 92
YAV26-L2TC38-FX
92
YAV26-L2TC38-FX-45
92
YAV26-L2TC38-FX-90
92
YAV26-L2TC516-FX
92
YAV26-L2TC516-FX-45
92
YAV26-L2TC516-FX-90
92
YAV26-L3
14
YAV26-L3 BOX
14
YAV26-RS
15
YAV26-RS3
15
YAV26-TC12-FXB
63
YAV26-TC38-FXB
63
YAV262N-FXB
104
YAV262NTC38-FXB
104
YAV262TC14-FXB
104
YAV262TC14E2-FXB
104
YAV262TC38-FXB
104
YAV26L-TC10-FX
52
YAV26L-TC10-FX-45
52
YAV26L-TC10-FX-90
52
YAV26L-TC12-FX
52
YAV26L-TC12-FX-45
52
YAV26L-TC12-FX-90
52
YAV26L-TC14-FX
52
YAV26L-TC14-FX-45
52
YAV26L-TC14-FX-90
52
YAV26L-TC34-FX
52
YAV26L-TC34-FX-45
52
YAV26L-TC34-FX-90
52
YAV26L-TC38-FX
52
YAV26L-TC38-FX-45
52
YAV26L-TC38-FX-90
52
YAV26L-TC516-FX
52
YAV26L-TC516-FX-45
52
YAV26L-TC516-FX-90
52
YAV26L-TC58-FX
52

CATALOG NO.
PAGE NO.
YAV26L-TC58-FX-45
52
YAV26L-TC58-FX-90
52
YAV27-L
14
YAV27-L BOX
14
YAV27-L1
14
YAV27-L1 BOX
14
YAV27-L15
14
YAV27-L15 BOX
14
YAV27-L2NTC-FX
92
YAV27-L2NTC-FX-45
92
YAV27-L2NTC-FX-90
92
YAV27-L2NTC516-FX
92
YAV27-L2NTC516-FX-45 92
YAV27-L2NTC516-FX-90 92
YAV27-L2TC14-FX
92
YAV27-L2TC14-FX-45
92
YAV27-L2TC14-FX-90
92
YAV27-L2TC38-FX
92
YAV27-L2TC38-FX-45
92
YAV27-L2TC38-FX-90
92
YAV27-RS
15
YAV27-TC12-FXB
63
YAV272N-FXB
104
YAV272TC14E2-FXB
104
YAV272TC38-FXB
104
YAV27L-TC10-FX
52
YAV27L-TC10-FX-45
52
YAV27L-TC10-FX-90
52
YAV27L-TC12-FX
52
YAV27L-TC12-FX-45
52
YAV27L-TC12-FX-90
52
YAV27L-TC14-FX
52
YAV27L-TC14-FX-45
52
YAV27L-TC14-FX-90
52
YAV27L-TC38-FX
52
YAV27L-TC38-FX-45
52
YAV27L-TC38-FX-90
52
YAV27L-TC516-FX
52
YAV27L-TC516-FX-45
52
YAV27L-TC516-FX-90
52
YAV28-L
14
YAV28-L BOX
14
YAV28-L12
14
YAV28-L12 BOX
14
YAV28-L13
14
YAV28-L13 BOX
14
YAV28-L14
14
YAV28-L14 BOX
14
YAV28-L2NT38-FX
93
YAV28-L2NT38-FX-45
93
YAV28-L2NT38-FX-90
93
YAV28-L2NTC-FX
92, 93
YAV28-L2NTC-FX-45 92, 93
YAV28-L2NTC-FX-90 92, 93
YAV28-L2TC12-FX
93
YAV28-L2TC12-FX-45
93
YAV28-L2TC12-FX-90
93
YAV28-L2TC14-FX
92
YAV28-L2TC14-FX-45
92
YAV28-L2TC14-FX-90
92
YAV28-L2TC14E2
93
YAV28-L2TC14E2-45
93
YAV28-L2TC14E2-90
93
YAV28-L2TC14E2-FX
92
YAV28-L2TC14E2-FX-45 92
YAV28-L2TC14E2-FX-90 92
YAV28-L2TC38-FX
92
YAV28-L2TC38-FX-45
92
YAV28-L2TC38-FX-90
92
YAV28-L2TC516-FX
92
YAV28-L2TC516-FX-45
92
YAV28-L2TC516-FX-90
92
YAV28-LTC12E1-FX
93
YAV28-LTC12E1-FX-45
93
YAV28-LTC12E1-FX-90
93
YAV28-RS
15

CATALOG NO.
PAGE NO.
YAV28-TC12-FXB
63
YAV28-TC38-FXB
63
YAV282N-FXB
104
YAV282NT38-FXB
104
YAV282NTC38-FXB
104
YAV282TC14E2-FXB
104
YAV282TC38-FXB
104
YAV282TC38-FXB-45
104
YAV282TC38-FXB-90
104
YAV28L-TC12-FX
53
YAV28L-TC12-FX-45
53
YAV28L-TC12-FX-90
53
YAV28L-TC14-FX
53
YAV28L-TC14-FX-45
53
YAV28L-TC14-FX-90
53
YAV28L-TC34-FX
53
YAV28L-TC34-FX-45
53
YAV28L-TC34-FX-90
53
YAV28L-TC38-FX
53
YAV28L-TC38-FX-45
53
YAV28L-TC38-FX-90
53
YAV28L-TC516-FX
53
YAV28L-TC516-FX-45
53
YAV28L-TC516-FX-90
53
YAV28L-TC58-FX
53
YAV28L-TC58-FX-45
53
YAV28L-TC58-FX-90
53
YAV29-L2NT38-FX
93
YAV29-L2NT38-FX-45
93
YAV29-L2NT38-FX-90
93
YAV29-L2NTC-FX
93
YAV29-L2NTC-FX-45
93
YAV29-L2NTC-FX-90
93
YAV29-L2TC12-FX
93
YAV29-L2TC12-FX-45
93
YAV29-L2TC12-FX-90
93
YAV29-L2TC14-FX
93
YAV29-L2TC14-FX-45
93
YAV29-L2TC14-FX-90
93
YAV29-L2TC14E2-FX
93
YAV29-L2TC14E2-FX-45 93
YAV29-L2TC14E2-FX-90 93
YAV29-L2TC38-FX
93
YAV29-L2TC38-FX-45
93
YAV29-L2TC38-FX-90
93
YAV29-L2TC516-FX
93
YAV29-L2TC516-FX-45
93
YAV29-L2TC516-FX-90
93
YAV29-LTC12E1-FX
93
YAV29-LTC12E1-FX-45
93
YAV29-LTC12E1-FX-90
93
YAV292N-FXB
104
YAV292NT38-FXB
104
YAV292NTC38-FXB
104
YAV292TC14E2-FXB
104
YAV292TC38-FXB
104
YAV292TC38-FXB-45
104
YAV292TC38-FXB-90
104
YAV29L-TC12-FX
53
YAV29L-TC12-FX-45
53
YAV29L-TC12-FX-90
53
YAV29L-TC14-FX
53
YAV29L-TC14-FX-45
53
YAV29L-TC14-FX-90
53
YAV29L-TC34-FX
53
YAV29L-TC34-FX-45
53
YAV29L-TC34-FX-90
53
YAV29L-TC38-FX
53
YAV29L-TC38-FX-45
53
YAV29L-TC38-FX-90
53
YAV29L-TC516-FX
53
YAV29L-TC516-FX-45
53
YAV29L-TC516-FX-90
53
YAV29L-TC58-FX
53
YAV29L-TC58-FX-45
53
YAV29L-TC58-FX-90
53

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YAV2C-L
13
YAV2C-L BOX
13
YAV2C-L1
13
YAV2C-L1 BOX
13
YAV2C-L2
13
YAV2C-L2 BOX
13
YAV2C-L2NTC-FX
91
YAV2C-L2NTC-FX-45
91
YAV2C-L2NTC-FX-90
91
YAV2C-L2TC14-FX
90
YAV2C-L2TC14-FX-45
90
YAV2C-L2TC14-FX-90
90
YAV2C-L2TC14E1-FX
91
YAV2C-L2TC14E1-FX-45 91
YAV2C-L2TC14E1-FX-90 91
YAV2C-L2TC14E2-FX
90
YAV2C-L2TC14E2-FX-45 90
YAV2C-L2TC14E2-FX-90 90
YAV2C-L2TC38-FX
91
YAV2C-L2TC38-FX-45
91
YAV2C-L2TC38-FX-90
91
YAV2C-L2TC516-FX
91
YAV2C-L2TC516-FX-45
91
YAV2C-L2TC516-FX-90
91
YAV2C-L3
13
YAV2C-L4
13
YAV2C-L4 BOX
13
YAV2C-RS
15
YAV2C-RS1
15
YAV2C-RS2
15
YAV2C-TC10-FXB
63
YAV2C-TC516-FXB
63
YAV2C2N-FXB
103
YAV2C2NT38-FXB
103
YAV2C2TC14-FXB
103
YAV2C2TC14E1-FXB
103
YAV2C2TC14E2-FXB
103
YAV2C2TC38-FXB
103
YAV2C2TC516-FXB
103
YAV2CL-TC10-FX
51
YAV2CL-TC10-FX-45
51
YAV2CL-TC10-FX-90
51
YAV2CL-TC12-FX
51
YAV2CL-TC12-FX-45
51
YAV2CL-TC12-FX-90
51
YAV2CL-TC14-FX
51
YAV2CL-TC14-FX-45
51
YAV2CL-TC14-FX-90
51
YAV2CL-TC38-FX
51
YAV2CL-TC38-FX-45
51
YAV2CL-TC38-FX-90
51
YAV2CL-TC516-FX
51
YAV2CL-TC516-FX-45
51
YAV2CL-TC516-FX-90
51
YAV4C-L
13
YAV4C-L BOX
13
YAV4C-L2
13
YAV4C-L2 BOX
13
YAV4C-L2NT10-FX
90
YAV4C-L2NT10-FX-45
90
YAV4C-L2NT10-FX-90
90
YAV4C-L2NT10E1-FX
90
YAV4C-L2NT10E1-FX-45 90
YAV4C-L2NT10E1-FX-90 90
YAV4C-L2NTC-FX
90
YAV4C-L2NTC-FX-45
90
YAV4C-L2NTC-FX-90
90
YAV4C-L2TC14-FX
90
YAV4C-L2TC14-FX-45
90
YAV4C-L2TC14-FX-90
90
YAV4C-L2TC14E1-FX
90
YAV4C-L2TC14E1-FX-45 90
YAV4C-L2TC14E1-FX-90 90
YAV4C-L2TC14E2-FX
90
YAV4C-L2TC14E2-FX-45 90
YAV4C-L2TC14E2-FX-90 90

CATALOG NO.
PAGE NO.
YAV4C-L2TC38-FX
90
YAV4C-L2TC38-FX-45
90
YAV4C-L2TC38-FX-90
90
YAV4C-L2TC516-FX
90
YAV4C-L2TC516-FX-45
90
YAV4C-L2TC516-FX-90
90
YAV4C-L3
13
YAV4C-L3 BOX
13
YAV4C-L4
13
YAV4C-L4 BOX
13
YAV4C-L5
13
YAV4C-L5 BOX
13
YAV4C-RS
15
YAV4C-RS2
15
YAV4C-RS3
15
YAV4C-RS4
15
YAV4C-TC10-FXB
63
YAV4C-TC14-FXB
63
YAV4C-TC516-FXB
63
YAV4C2N-FXB
103
YAV4C2TC14-FXB
103
YAV4C2TC14E1-FXB
103
YAV4C2TC14E2-FXB
103
YAV4C2TC38-FXB
103
YAV4C2TC516-FXB
103
YAV4CL-TC10-FX
51
YAV4CL-TC10-FX-45
51
YAV4CL-TC10-FX-90
51
YAV4CL-TC12-FX
51
YAV4CL-TC12-FX-45
51
YAV4CL-TC12-FX-90
51
YAV4CL-TC14-FX
51
YAV4CL-TC14-FX-45
51
YAV4CL-TC14-FX-90
51
YAV4CL-TC38-FX
51
YAV4CL-TC38-FX-45
51
YAV4CL-TC38-FX-90
51
YAV4CL-TC516-FX
51
YAV4CL-TC516-FX-45
51
YAV4CL-TC516-FX-90
51
YAV5C-TC14-FXB
63
YAV5C2TC14-FXB
103
YAV6C-L
13
YAV6C-L BOX
13
YAV6C-L1
13
YAV6C-L1 BOX
13
YAV6C-L10
13
YAV6C-L10 BOX
13
YAV6C-L2
13
YAV6C-L2 BOX
13
YAV6C-L2NTC-FX
90
YAV6C-L2NTC-FX-45
90
YAV6C-L2NTC-FX-90
90
YAV6C-L2TC10-FX
89
YAV6C-L2TC10-FX-45
89
YAV6C-L2TC10-FX-90
89
YAV6C-L2TC10E2-FX
89
YAV6C-L2TC10E2-FX-45 89
YAV6C-L2TC10E2-FX-90 89
YAV6C-L2TC10E4-FX
89
YAV6C-L2TC10E4-FX-45 89
YAV6C-L2TC10E4-FX-90 89
YAV6C-L2TC10E9-FX
89
YAV6C-L2TC10E9-FX-45 89
YAV6C-L2TC10E9-FX-90 89
YAV6C-L2TC14-FX
90
YAV6C-L2TC14-FX-45
90
YAV6C-L2TC14-FX-90
90
YAV6C-L2TC14E1-FX
90
YAV6C-L2TC14E1-FX-45 90
YAV6C-L2TC14E1-FX-90 90
YAV6C-L2TC14E2-FX
90
YAV6C-L2TC14E2-FX-45 90
YAV6C-L2TC14E2-FX-90 90
YAV6C-L2TC38-FX
90
YAV6C-L2TC38-FX-45
90

CATALOG NO.
PAGE NO.
YAV6C-L2TC38-FX-90
90
YAV6C-L2TC516-FX
90
YAV6C-L2TC516-FX-45
90
YAV6C-L2TC516-FX-90
90
YAV6C-L4
13
YAV6C-L4 BOX
13
YAV6C-RS
15
YAV6C-RS1
15
YAV6C-RS2
15
YAV6C-RS4
15
YAV6C-TC10-FXB
63
YAV6C-TC14-FXB
63
YAV6C2N-FXB
103
YAV6C2TC14-FXB
103
YAV6C2TC14E2-FXB
103
YAV6C2TC38-FXB
103
YAV6CL-TC10-FX
50
YAV6CL-TC10-FX-45
50
YAV6CL-TC10-FX-90
50
YAV6CL-TC12-FX
50
YAV6CL-TC12-FX-45
50
YAV6CL-TC12-FX-90
50
YAV6CL-TC14-FX
50
YAV6CL-TC14-FX-45
50
YAV6CL-TC14-FX-90
50
YAV6CL-TC34-FX
51
YAV6CL-TC34-FX-45
51
YAV6CL-TC34-FX-90
51
YAV6CL-TC38-FX
50
YAV6CL-TC38-FX-45
50
YAV6CL-TC38-FX-90
50
YAV6CL-TC516-FX
50
YAV6CL-TC516-FX-45
50
YAV6CL-TC516-FX-90
50
YAV8C-L
13
YAV8C-L BOX
13
YAV8C-L1
13
YAV8C-L1 BOX
13
YAV8C-L14
13
YAV8C-L2
13
YAV8C-L2 BOX
13
YAV8C-L3
13
YAV8C-L3 BOX
13
YAV8C-L4
13
YAV8C-L4 BOX
13
YAV8C-RS
15
YAV8C-RS1
15
YAV8C-RS3
15
YAV9C-L36
12
YAV9C-L36 BOX
12
YAV9C-T4 BOX
12
YAV9C-T9
12
YAV9C-T9 BOX
12
YAZ1C-2N
84
YAZ1C-2N-45
84
YAZ1C-2N-90
84
YAZ1C-2TC14
84
YAZ1C-2TC14-45
84
YAZ1C-2TC14-90
84
YAZ1C-2TC14E2
84
YAZ1C-2TC14E2-45
84
YAZ1C-2TC14E2-90
84
YAZ1C-2TC38
84
YAZ1C-2TC38-45
84
YAZ1C-2TC38-90
84
YAZ1C-TC12
47
YAZ1C-TC12-45
47
YAZ1C-TC12-90
47
YAZ1C-TC14
47
YAZ1C-TC14-45
47
YAZ1C-TC14-90
47
YAZ1C-TC38
47
YAZ1C-TC38-45
47
YAZ1C-TC38-90
47
YAZ25-2N
84
YAZ25-2N-45
84

CATALOG NO.
PAGE NO.
YAZ25-2N-90
84
YAZ25-2NTC38
85
YAZ25-2NTC38-45
85
YAZ25-2NTC38-90
85
YAZ25-2TC14
85
YAZ25-2TC14-45
85
YAZ25-2TC14-90
85
YAZ25-2TC14E1
85
YAZ25-2TC14E1-45
85
YAZ25-2TC14E1-90
85
YAZ25-2TC14E2
85
YAZ25-2TC14E2-45
85
YAZ25-2TC14E2-90
85
YAZ25-2TC38
85
YAZ25-2TC38-45
85
YAZ25-2TC38-90
85
YAZ25-2TC516
85
YAZ25-2TC516-45
85
YAZ25-2TC516-90
85
YAZ25-2TC516E6
85
YAZ25-2TC516E6-45
85
YAZ25-2TC516E6-90
85
YAZ25-TC12
47
YAZ25-TC12-45
47
YAZ25-TC12-90
47
YAZ25-TC14
47
YAZ25-TC14-45
47
YAZ25-TC14-90
47
YAZ25-TC38
47
YAZ25-TC38-45
47
YAZ25-TC38-90
47
YAZ25-TC516
47
YAZ25-TC516-45
47
YAZ25-TC516-90
47
YAZ26-2N
85
YAZ26-2N-45
85
YAZ26-2N-90
85
YAZ26-2TC14
85
YAZ26-2TC14-45
85
YAZ26-2TC14-90
85
YAZ26-2TC14E2
85
YAZ26-2TC14E2-45
85
YAZ26-2TC14E2-90
85
YAZ26-2TC38
85
YAZ26-2TC38-45
85
YAZ26-2TC38-90
85
YAZ26-TC12
47
YAZ26-TC12-45
47
YAZ26-TC12-90
47
YAZ26-TC14
47
YAZ26-TC14-45
47
YAZ26-TC14-90
47
YAZ26-TC38
47
YAZ26-TC38-45
47
YAZ26-TC38-90
47
YAZ27-2N
85
YAZ27-2N-45
85
YAZ27-2N-90
85
YAZ27-2TC14E2
85
YAZ27-2TC14E2-45
85
YAZ27-2TC14E2-90
85
YAZ27-2TC38
85
YAZ27-2TC38-45
85
YAZ27-2TC38-90
85
YAZ27-TC12
48
YAZ27-TC12-45
48
YAZ27-TC12-90
48
YAZ27-TC38
47
YAZ27-TC38-45
47
YAZ27-TC38-90
47
YAZ28-2N
85
YAZ28-2N-45
85
YAZ28-2N-90
85
YAZ28-2NTC38
86
YAZ28-2NTC38-45
86
YAZ28-2NTC38-90
86

CATALOG NO.
PAGE NO.
YAZ28-2TC14E2
85
YAZ28-2TC14E2-45
85
YAZ28-2TC14E2-90
85
YAZ28-2TC38
86
YAZ28-2TC38-45
86
YAZ28-2TC38-90
86
YAZ28-TC12
48
YAZ28-TC12-45
48
YAZ28-TC12-90
48
YAZ28-TC38
48
YAZ28-TC38-45
48
YAZ28-TC38-90
48
YAZ29-2N
86
YAZ29-2N-45
86
YAZ29-2N-90
86
YAZ29-2TC38
86
YAZ29-2TC38-45
86
YAZ29-2TC38-90
86
YAZ29-TC12
48
YAZ29-TC12-45
48
YAZ29-TC12-90
48
YAZ29-TC38
48
YAZ29-TC38-45
48
YAZ29-TC38-90
48
YAZ2C-2N
84
YAZ2C-2N-45
84
YAZ2C-2N-90
84
YAZ2C-2NTC38
84
YAZ2C-2NTC38-45
84
YAZ2C-2NTC38-90
84
YAZ2C-2TC10E2
84
YAZ2C-2TC10E2-45
84
YAZ2C-2TC10E2-90
84
YAZ2C-2TC14
84
YAZ2C-2TC14-45
84
YAZ2C-2TC14-90
84
YAZ2C-2TC14E1
84
YAZ2C-2TC14E1-45
84
YAZ2C-2TC14E1-90
84
YAZ2C-2TC14E2
84
YAZ2C-2TC14E2-45
84
YAZ2C-2TC14E2-90
84
YAZ2C-2TC38
84
YAZ2C-2TC38-45
84
YAZ2C-2TC38-90
84
YAZ2C-2TC38E2
84
YAZ2C-2TC38E2-45
84
YAZ2C-2TC38E2-90
84
YAZ2C-2TC38E6
84
YAZ2C-2TC38E6-45
84
YAZ2C-2TC38E6-90
84
YAZ2C-2TC516E2
84
YAZ2C-2TC516E2-45
84
YAZ2C-2TC516E2-90
84
YAZ2C-TC12
47
YAZ2C-TC12-45
47
YAZ2C-TC12-90
47
YAZ2C-TC14
47
YAZ2C-TC14-45
47
YAZ2C-TC14-90
47
YAZ2C-TC38
47
YAZ2C-TC38-45
47
YAZ2C-TC38-90
47
YAZ30-2N
86
YAZ30-2N-45
86
YAZ30-2N-90
86
YAZ30-2TC38
86
YAZ30-2TC38-45
86
YAZ30-2TC38-90
86
YAZ30-TC12
48
YAZ30-TC12-45
48
YAZ30-TC12-90
48
YAZ30-TC38
48
YAZ30-TC38-45
48
YAZ30-TC38-90
48
YAZ302TC38FX
108

229

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YAZ302TC38FX-45
108
YAZ302TC38FX-90
108
YAZ30TC38FX
66
YAZ30TC38FX-45
66
YAZ30TC38FX-90
66
YAZ31-2N
86
YAZ31-2N-45
86
YAZ31-2N-90
86
YAZ31-2TC14E2
86
YAZ31-2TC14E2-45
86
YAZ31-2TC14E2-90
86
YAZ31-2TC38
86
YAZ31-2TC38-45
86
YAZ31-2TC38-90
86
YAZ31-TC12
48
YAZ31-TC12-45
48
YAZ31-TC12-90
48
YAZ31-TC38
48
YAZ31-TC38-45
48
YAZ31-TC38-90
48
YAZ312TC14E2FX
108
YAZ312TC14E2FX-45
108
YAZ312TC14E2FX-90
108
YAZ312TC38FX
108
YAZ312TC38FX45
108
YAZ312TC38FX90
108
YAZ31TC38FX
66
YAZ31TC38FX45
66
YAZ31TC38FX90
66
YAZ32-2N
86
YAZ32-2N-45
86
YAZ32-2N-90
86
YAZ32-2TC38
86
YAZ32-2TC38-45
86
YAZ32-2TC38-90
86
YAZ32-TC12
48
YAZ32-TC12-45
48
YAZ32-TC12-90
48
YAZ32-TC38
48
YAZ32-TC38-45
48
YAZ32-TC38-90
48
YAZ322TC38FX
108
YAZ322TC38FX45
108
YAZ322TC38FX90
108
YAZ32TC38FX
66
YAZ32TC38FX45
66
YAZ32TC38FX90
66
YAZ33-2N
86
YAZ33-2N-45
86
YAZ33-2N-90
86
YAZ33-TC12
48
YAZ33-TC12-45
48
YAZ33-TC12-90
48
YAZ34-2N
86
YAZ34-2N-45
86
YAZ34-2N-90
86
YAZ34-2TC14E2
86
YAZ34-2TC14E2-45
86
YAZ34-2TC14E2-90
86
YAZ34-2TC38
86
YAZ34-2TC38-45
86
YAZ34-2TC38-90
86
YAZ34-TC12
48
YAZ34-TC12-45
48
YAZ34-TC12-90
48
YAZ34-TC38
48
YAZ34-TC38-45
48
YAZ34-TC38-90
48
YAZ342NT38FX
108
YAZ342NT38FX-45
108
YAZ342NT38FX-90
108
YAZ342NTCFX
108
YAZ342NTCFX45
108
YAZ342NTCFX90
108
YAZ342TC14E2FX
108
YAZ342TC14E2FX-45
108

230

CATALOG NO.
PAGE NO.
YAZ342TC14E2FX-90
108
YAZ342TC38FX
108
YAZ342TC38FX45
108
YAZ342TC38FX90
108
YAZ34NT38FX
67
YAZ34NT38FX-45
67
YAZ34NT38FX-90
67
YAZ34TC12FX
67
YAZ34TC12FX45
67
YAZ34TC12FX90
67
YAZ34TC38FX
67
YAZ34TC38FX45
67
YAZ34TC38FX90
67
YAZ35-2N
86
YAZ35-2N-45
86
YAZ35-2N-90
86
YAZ35-TC12
48
YAZ35-TC12-45
48
YAZ35-TC12-90
48
YAZ36-2N
87
YAZ36-2N-45
87
YAZ36-2N-90
87
YAZ36-2TC38
87
YAZ36-2TC38-45
87
YAZ36-2TC38-90
87
YAZ36-TC12
49
YAZ36-TC12-45
49
YAZ36-TC12-90
49
YAZ36-TC38
48
YAZ36-TC38-45
48
YAZ36-TC38-90
48
YAZ362TC38FX
108
YAZ362TC38FX45
108
YAZ362TC38FX90
108
YAZ36TC38FX
67
YAZ36TC38FX45
67
YAZ36TC38FX90
67
YAZ37-2N
87
YAZ37-2N-45
87
YAZ37-2N-90
87
YAZ37-TC12
49
YAZ37-TC12-45
49
YAZ37-TC12-90
49
YAZ38-2N
87
YAZ38-2N-45
87
YAZ38-2N-90
87
YAZ38-TC12
49
YAZ38-TC12-45
49
YAZ38-TC12-90
49
YAZ382NNTFX
108
YAZ382NNTFX-45
108
YAZ382NNTFX-90
108
YAZ382NT38FX
108
YAZ382NT38FX-45
108
YAZ382NT38FX-90
108
YAZ382NTCFX
108
YAZ382NTCFX45
108
YAZ382NTCFX90
108
YAZ382TC38FX
108
YAZ382TC38FX45
108
YAZ382TC38FX90
108
YAZ38NT12FX
67
YAZ38NT12FX-45
67
YAZ38NT12FX-90
67
YAZ38NT38FX
67
YAZ38NT38FX-45
67
YAZ38NT38FX-90
67
YAZ38TC12FX
67
YAZ38TC12FX45
67
YAZ38TC12FX90
67
YAZ38TC38FX
67
YAZ38TC38FX45
67
YAZ38TC38FX90
67
YAZ39-2N
87
YAZ39-2N-45
87
YAZ39-2N-90
87

CATALOG NO.
PAGE NO.
YAZ39-2NNT
87
YAZ39-2NNT-45
87
YAZ39-2NNT-90
87
YAZ39-2NT38
87
YAZ39-2NT38-45
87
YAZ39-2NT38-90
87
YAZ39-2TC38
87
YAZ39-2TC38-45
87
YAZ39-2TC38-90
87
YAZ39-NT12
49
YAZ39-NT12-45
49
YAZ39-NT12-90
49
YAZ39-TC12
49
YAZ39-TC12-45
49
YAZ39-TC12-90
49
YAZ39-TC38
49
YAZ39-TC38-45
49
YAZ39-TC38-90
49
YAZ3C-2N
83
YAZ3C-2N-45
83
YAZ3C-2N-90
83
YAZ3C-2TC14
83
YAZ3C-2TC14-45
83
YAZ3C-2TC14-90
83
YAZ3C-2TC14E2
83
YAZ3C-2TC14E2-45
83
YAZ3C-2TC14E2-90
83
YAZ3C-2TC38
84
YAZ3C-2TC38-45
84
YAZ3C-2TC38-90
84
YAZ3C-2TC38E2
83
YAZ3C-2TC38E2-45
83
YAZ3C-2TC38E2-90
83
YAZ3C-TC12
47
YAZ3C-TC12-45
47
YAZ3C-TC12-90
47
YAZ3C-TC14
47
YAZ3C-TC14-45
47
YAZ3C-TC14-90
47
YAZ3C-TC38
47
YAZ3C-TC38-45
47
YAZ3C-TC38-90
47
YAZ40-2N
87
YAZ40-2N-45
87
YAZ40-2N-90
87
YAZ40-TC12
49
YAZ40-TC12-45
49
YAZ40-TC12-90
49
YAZ41-2N
87
YAZ41-2N-45
87
YAZ41-2N-90
87
YAZ41-TC12
49
YAZ41-TC12-45
49
YAZ41-TC12-90
49
YAZ44-2N
87
YAZ44-2N-45
87
YAZ44-2N-90
87
YAZ44-2TC38
87
YAZ44-2TC38-45
87
YAZ44-2TC38-90
87
YAZ44-TC12
49
YAZ44-TC12-45
49
YAZ44-TC12-90
49
YAZ44-TC38
49
YAZ44-TC38-45
49
YAZ44-TC38-90
49
YAZ45-2N
87
YAZ45-2N-45
87
YAZ45-2N-90
87
YAZ45-TC12
49
YAZ45-TC12-45
49
YAZ45-TC12-90
49
YAZ453-2N
87
YAZ453-2N-45
87
YAZ453-2N-90
87
YAZ453-TC12
49

CATALOG NO.
PAGE NO.
YAZ453-TC12-45
49
YAZ453-TC12-90
49
YAZ46-2N
87
YAZ46-2N-45
87
YAZ46-2N-90
87
YAZ46-TC12
49
YAZ46-TC12-45
49
YAZ46-TC12-90
49
YAZ47-2N
87
YAZ47-2N-45
87
YAZ47-2N-90
87
YAZ47-TC12
49
YAZ47-TC12-45
49
YAZ47-TC12-90
49
YAZ48-2N
88
YAZ48-2N-45
88
YAZ48-2N-90
88
YAZ48-TC12
49
YAZ48-TC12-45
49
YAZ48-TC12-90
49
YAZ4C-2N
83
YAZ4C-2N-45
83
YAZ4C-2N-90
83
YAZ4C-2TC10-E2
83
YAZ4C-2TC10-E245
83
YAZ4C-2TC10-E290
83
YAZ4C-2TC14
83
YAZ4C-2TC14-45
83
YAZ4C-2TC14-90
83
YAZ4C-2TC14E2
83
YAZ4C-2TC14E2-45
83
YAZ4C-2TC14E2-90
83
YAZ4C-2TC38
83
YAZ4C-2TC38-45
83
YAZ4C-2TC38-90
83
YAZ4C-TC12
46
YAZ4C-TC12-45
46
YAZ4C-TC12-90
46
YAZ4C-TC14
46
YAZ4C-TC14-45
46
YAZ4C-TC14-90
46
YAZ4C-TC38
46
YAZ4C-TC38-45
46
YAZ4C-TC38-90
46
YAZ5C-2N
83
YAZ5C-2N-45
83
YAZ5C-2N-90
83
YAZ5C-TC12
46
YAZ5C-TC12-45
46
YAZ5C-TC12-90
46
YAZ6C-2N
82
YAZ6C-2N-45
82
YAZ6C-2N-90
82
YAZ6C-2TC10E2
82
YAZ6C-2TC10E2-45
82
YAZ6C-2TC10E2-90
82
YAZ6C-2TC14
83
YAZ6C-2TC14-45
83
YAZ6C-2TC14-90
83
YAZ6C-2TC14E1
83
YAZ6C-2TC14E1-45
83
YAZ6C-2TC14E1-90
83
YAZ6C-2TC14E2
83
YAZ6C-2TC14E2-45
83
YAZ6C-2TC14E2-90
83
YAZ6C-2TC38
83
YAZ6C-2TC38-45
83
YAZ6C-2TC38-90
83
YAZ6C-2TC38E2
83
YAZ6C-2TC38E2-45
83
YAZ6C-2TC38E2-90
83
YAZ6C-2TC38E6
83
YAZ6C-2TC38E6-45
83
YAZ6C-2TC38E6-90
83
YAZ6C-TC12
46
YAZ6C-TC12-45
46

CATALOG NO.
PAGE NO.
YAZ6C-TC12-90
46
YAZ6C-TC14
46
YAZ6C-TC14-45
46
YAZ6C-TC14-90
46
YAZ6C-TC38
46
YAZ6C-TC38-45
46
YAZ6C-TC38-90
46
YAZ8C-2TC10
82
YAZ8C-2TC10-45
82
YAZ8C-2TC10-90
82
YAZ8C-2TC10E2
82
YAZ8C-2TC10E2-45
82
YAZ8C-2TC10E2-90
82
YAZ8C-2TC14
82
YAZ8C-2TC14-45
82
YAZ8C-2TC14-90
82
YAZ8C-2TC14E1
82
YAZ8C-2TC14E1-45
82
YAZ8C-2TC14E1-90
82
YAZ8C-2TC14E2
82
YAZ8C-2TC14E2-45
82
YAZ8C-2TC14E2-90
82
YAZ8C-2TC38
82
YAZ8C-2TC38-45
82
YAZ8C-2TC38-90
82
YAZ8C-TC10
46, 65
YAZ8C-TC10-45
46, 65
YAZ8C-TC10-90
46, 65
YAZ8C-TC14
46, 65
YAZ8C-TC14-45
46, 65
YAZ8C-TC14-90
46, 65
YAZ8C-TC38
46, 65
YAZ8C-TC38-45
46, 65
YAZ8C-TC38-90
46, 65
YAZ8C2TC10E2FX
105
YAZ8C2TC10E2FX45
105
YAZ8C2TC10E2FX90
105
YAZ8C2TC10FX
105
YAZ8C2TC10FX45
105
YAZ8C2TC10FX90
105
YAZ8C2TC14E1FX
105
YAZ8C2TC14E1FX45
105
YAZ8C2TC14E1FX90
105
YAZ8C2TC14E2FX
105
YAZ8C2TC14E2FX45
105
YAZ8C2TC14E2FX90
105
YAZ8C2TC14FX
105
YAZ8C2TC14FX45
105
YAZ8C2TC14FX90
105
YAZ8C2TC38FX
105
YAZ8C2TC38FX45
105
YAZ8C2TC38FX90
105
YAZV10-2TC14
82
YAZV10-2TC14-45
82
YAZV10-2TC14-90
82
YAZV10-2TC14E2
82
YAZV10-2TC14E2-45
82
YAZV10-2TC14E2-90
82
YAZV10-TC14
46
YAZV10-TC14-45
46
YAZV10-TC14-90
46
YAZV1C2TC14E1FX
106
YAZV1C2TC14E1FX45
106
YAZV1C2TC14E1FX90
106
YAZV1C2TC14E2FX
106
YAZV1C2TC14E2FX45
106
YAZV1C2TC14E2FX90
106
YAZV1C2TC14FX
106
YAZV1C2TC14FX45
106
YAZV1C2TC14FX90
106
YAZV1C2TC38FX
106
YAZV1C2TC38FX45
106
YAZV1C2TC38FX90
106
YAZV1C2TC516E6FX
106
YAZV1C2TC516E6FX-45 106
YAZV1C2TC516E6FX-90 106

BURNDY
Telecommunications Products
CATALOG NO.
PAGE NO.
YAZV1C2TC516FX
106
YAZV1C2TC516FX45
106
YAZV1C2TC516FX90
106
YAZV1CTC14FX
65
YAZV1CTC14FX45
65
YAZV1CTC14FX90
65
YAZV1CTC38FX
66
YAZV1CTC38FX45
66
YAZV1CTC38FX90
66
YAZV1CTC516FX
66
YAZV1CTC516FX45
66
YAZV1CTC516FX90
66
YAZV252NTCFX
107
YAZV252NTCFX45
107
YAZV252NTCFX90
107
YAZV252TC14E2FX
107
YAZV252TC14E2FX45
107
YAZV252TC14E2FX90
107
YAZV252TC14FX
107
YAZV252TC14FX45
107
YAZV252TC14FX90
107
YAZV252TC38FX
107
YAZV252TC38FX45
107
YAZV252TC38FX90
107
YAZV25TC12FX
66
YAZV25TC12FX45
66
YAZV25TC12FX90
66
YAZV25TC14FX
66
YAZV25TC14FX45
66
YAZV25TC14FX90
66
YAZV25TC38FX
66
YAZV25TC38FX45
66
YAZV25TC38FX90
66
YAZV262NTCFX
107
YAZV262NTCFX45
107
YAZV262NTCFX90
107
YAZV262TC14E2FX
107
YAZV262TC14E2FX45
107
YAZV262TC14E2FX90
107
YAZV262TC14FX
107
YAZV262TC14FX45
107
YAZV262TC14FX90
107
YAZV262TC38FX
107
YAZV262TC38FX45
107
YAZV262TC38FX90
107
YAZV26TC12FX
66
YAZV26TC12FX45
66
YAZV26TC12FX90
66
YAZV26TC14FX
66
YAZV26TC14FX45
66
YAZV26TC14FX90
66
YAZV26TC38FX
66
YAZV26TC38FX45
66
YAZV26TC38FX90
66
YAZV272TC14E2FX
107
YAZV272TC14E2FX-45 107
YAZV272TC14E2FX-90 107
YAZV272TC38FX
107
YAZV272TC38FX45
107
YAZV272TC38FX90
107
YAZV27TC38FX
66
YAZV27TC38FX45
66
YAZV27TC38FX90
66
YAZV282NT38FX
107
YAZV282NT38FX-45
107
YAZV282NT38FX-90
107
YAZV282NTCFX
107
YAZV282NTCFX45
107
YAZV282NTCFX90
107
YAZV282TC14E2FX
107
YAZV282TC14E2FX45
107
YAZV282TC14E2FX90
107
YAZV282TC38FX
107
YAZV282TC38FX45
107
YAZV282TC38FX90
107
YAZV28NT38FX
66

CATALOG NO.
PAGE NO.
YAZV28NT38FX-45
66
YAZV28NT38FX-90
66
YAZV28TC12FX
66
YAZV28TC12FX45
66
YAZV28TC12FX90
66
YAZV28TC38FX
66
YAZV28TC38FX45
66
YAZV28TC38FX90
66
YAZV292NT516FX
107
YAZV292NT516FX-45
107
YAZV292NT516FX-90
107
YAZV29NT516FX
66
YAZV29NT516FX-45
66
YAZV29NT516FX-90
66
YAZV2C2NTCFX
106
YAZV2C2NTCFX45
106
YAZV2C2NTCFX90
106
YAZV2C2TC14E2FX
106
YAZV2C2TC14E2FX45
106
YAZV2C2TC14E2FX90
106
YAZV2C2TC14FX
106
YAZV2C2TC14FX45
106
YAZV2C2TC14FX90
106
YAZV2C2TC38FX
106
YAZV2C2TC38FX45
106
YAZV2C2TC38FX90
106
YAZV2CTC12FX
65
YAZV2CTC12FX45
65
YAZV2CTC12FX90
65
YAZV2CTC14FX
65
YAZV2CTC14FX45
65
YAZV2CTC14FX90
65
YAZV2CTC38FX
65
YAZV2CTC38FX45
65
YAZV2CTC38FX90
65
YAZV4C2TC14E2FX
106
YAZV4C2TC14E2FX45
106
YAZV4C2TC14E2FX90
106
YAZV4C2TC14FX
106
YAZV4C2TC14FX45
106
YAZV4C2TC14FX90
106
YAZV4C2TC38E2-FX
106
YAZV4C2TC38E2-FX-45 106
YAZV4C2TC38E2-FX-90 106
YAZV4C2TC38FX
106
YAZV4C2TC38FX45
106
YAZV4C2TC38FX90
106
YAZV4CTC14FX
65
YAZV4CTC14FX45
65
YAZV4CTC14FX90
65
YAZV4CTC38FX
65
YAZV4CTC38FX45
65
YAZV4CTC38FX90
65
YAZV6C2TC10E2FX
105
YAZV6C2TC10E2FX45
105
YAZV6C2TC10E2FX90
105
YAZV6C2TC14E1FX
105
YAZV6C2TC14E1FX45
105
YAZV6C2TC14E1FX90
105
YAZV6C2TC14E2FX
105
YAZV6C2TC14E2FX45
105
YAZV6C2TC14E2FX90
105
YAZV6C2TC14FX
105
YAZV6C2TC14FX45
105
YAZV6C2TC14FX90
105
YAZV6C2TC38E2FX
106
YAZV6C2TC38E2FX-45 106
YAZV6C2TC38E2FX-90 106
YAZV6C2TC38E6FX
106
YAZV6C2TC38E6FX-45 106
YAZV6C2TC38E6FX-90 106
YAZV6C2TC38FX
105
YAZV6C2TC38FX45
105
YAZV6C2TC38FX90
105
YAZV6CTC14FX
65
YAZV6CTC14FX45
65

CATALOG NO.
PAGE NO.
YAZV6CTC14FX90
65
YAZV6CTC38FX
65
YAZV6CTC38FX45
65
YAZV6CTC38FX90
65
YC10L12
119
YC1L12
119
YC25L12
119
YC26L12
119
YC27L12
119
YC2L12
119
YC3L12
119
YC4L12
119
YC6L12
119
YC8L12
119
YCC-CASE
211
YCHC29TC2
120
YCHC29TC29
120
YCHC2TC2
120
YCHC34TC2
120
YCHC34TC29
120
YCHC34TC34
120
YCHC39TC2
120
YCHC39TC31
120
YCHC39TC39
120
YCHC44TC44
120
YCHC8TC8
120
YCUT129ACSR
192
YDC-CASE
194
YG14B2TC2C2C
144
YG14B2TC2C6C
144
YG14BTC26
144
YG14BTC28
144
YGA25-2N
140
YGA26-2N
140
YGA28-2N
140
YGA29-2N
140
YGA2C-2N
140
YGA2C-2TC38
140
YGA2C-2TC38E2G1
140
YGA34-2N
140
YGA6C-2N
140
YGA6C-2TC38E2G1
140
YGA6C-TC10
140
YGA6C-TC14
140
YGA6C-TC516
140
YGA8C-2N
140
YGA8C-TC10
140
YGA8C-TC14
140
YGA8C-TC516
140
YGC6C6
135
YGC6C8
135
YGC8C8
135
YGHA25-2N
139
YGHA26-2N
139
YGHA27-2N
139
YGHA28-2N
139
YGHA29-2N
139
YGHA2C-2N
139
YGHA31-2N
139
YGHA34-2N
139
YGHC26C2
134
YGHC26C26
134
YGHC29C26
134
YGHC29C29
134
YGHC2C2
134
YGHC34C26
134
YGHC34C29
134
YGHC34C34
134
YGHP29C2
133
YGHP29C26
133
YGHP29C29
133
YGHP29C6W6W
133
YGHP2C2
133
YGHP2C6W6W
133
YGHP34C2
133
YGHP34C26
133

CATALOG NO.
PAGE NO.
YGHP34C29
133
YGHP34C34
133
YGHP58C2W-2
132
YGHP58C2W-2TN
132
YGHR58C2W-3
138
YGHS25
139
YGHS26
139
YGHS27
139
YGHS28
139
YGHS29
139
YGHS2C
139
YGHS31
139
YGHS34
139
YGIBS28-338-2N
143
YGIBS28-400-2N
143
YGIBS28-462-2N
143
YGIBS28-550-2N
143
YGIBS28-613-2N
143
YGIBS28-675-2N
143
YGIBS34-338-2N
143
YGIBS34-400-2N
143
YGIBS34-462-2N
143
YGIBS34-550-2N
143
YGIBS34-613-2N
143
YGIBS34-675-2N
143
YGIBW28-338-2M
143
YGIBW28-400-2N
143
YGIBW28-462-2N
143
YGIBW28-550-2N
143
YGIBW28-613-2N
143
YGIBW28-675-2N
143
YGIBW34-338-2N
143
YGIBW34-400-2N
143
YGIBW34-462-2N
143
YGIBW34-550-2N
143
YGIBW34-613-2N
143
YGIBW34-675-2N
143
YGL29C2
137
YGL29C29
137
YGL2C2
137
YGL34C2
137
YGL34C29
137
YGL34C34
137
YGS25
141
YGS26
141
YGS28
141
YGS29
141
YGS2C
141
YGS34
141
YGS6C
141
YGS8C
141
YH2929
122
YH292C
122
YH298C
122
YH2C2C
122
YH3429
122
YH3434
122
YH3931
122
YH3939
122
YH4429
122
YH4434
121, 123
YH4434WC
121
YH4444
122
YH6C6C
122
YH8C8C
122
YPK10SV50GRY
125
YPK14SV50GRY
125
YPK1CSV175GRY
125
YPK25SV175GRY
125
YPK26SV350BLU
125
YPK26SV350GRY
125
YPK6CSV50GRY
125
YPK8CSV50GRY
125
YPP10SV50
125
YPP14SV50
125
YPP1CSV175
125

CATALOG NO.
YPP25SV175
YPP26SV350
YPP6CSV50
YPP8CSV50
YR2C2WT
YRV2CV6C-L
YRV4CV6C-L
YRV6CV10-L
YRV6CV8C-L
YRV8CV10-L
YRV8CV14-L
YS1C
YS1C-L BOX
YS25
YS25-L BOX
YS25FXLTCKITC
YS25FXTCKITC
YS26
YS26-L BOX
YS26FXLTCKITC
YS26FXTCKITC
YS27
YS27-L BOX
YS28
YS28-L BOX
YS28LTCKITC
YS28TCKITC
YS29
YS29-L BOX
YS29FXLTCKITC
YS29FXTCKITC
YS2C
YS2C-L BOX
YS2CFXLTCKITC
YS2CFXTCKITC
YS30
YS30-FXB
YS30-L
YS31
YS31-FXB
YS31-L
YS31LTCKITC
YS31TCKITC
YS32
YS32-FXB
YS32-L
YS34
YS34-FXB
YS34-L
YS34FXLTCKITC
YS34FXTCKITC
YS34LTCKITC
YS34TCKITC
YS36
YS36-FXB
YS36-L
YS38-FXB
YS38-L
YS38FXLTCKITC
YS38FXTCKITC
YS39
YS39-L
YS39LTCKITC
YS39TCKITC
YS3C
YS3C-FXB
YS3C-L
YS40-FXB
YS44
YS44-FXB
YS44-L
YS44FXLTCKITC
YS44FXTCKITC
YS46
YS48
YS4C

PAGE NO.
125
125
125
125
114
26
26
26
26
26
26
114
112
114
112
116
116
114
112
116
116
114
112
114
112
116
116
114
112
116
116
114
112
116
116
114
115
112
114
115
112
116
116
114
115
112
114
115
112
116
116
116
116
114
115
112
115
112
116
116
114
112
116
116
114
115
112
115
114
115
112
116
116
114
114
114

231

BURNDY
Telecommunications Products
CATALOG NO.
YS4C-L BOX
YS5C
YS5C-FXB
YS5C-L BOX
YS6C
YS6C-L BOX
YS8C
YS8C-FXB
YS8C-L-BOX
YSCM104
YSCM133
YSCM167
YSCM17
YSCM212
YSCM231
YSCM27
YSCM42
YSCM66
YSCM80
YSE10
YSE10-BOX
YSE10HN
YSE14H
YSE14H-BOX
YSE14HN

232

PAGE NO.
112
114
115
112
114
112
114
115
112
113
113
113
113
113
113
113
113
113
113
25
25
24
25
25
24

CATALOG NO.
PAGE NO.
YSE18H
25
YSE18H-BOX
25
YSE18HN
24
YSES14-2
25
YSES18-1
25
YSHG3429
136
YSHG3434
136
YSHG3931
136
YSHG3939
136
YSHG4429
136
YSR25FX6CFXLTCKITC 118
YSR25FX6CFXTCKITC 118
YSR26FX6CFXLTCKITC 118
YSR26FX6CFXTCKITC 118
YSR2825FXLTCKITC
118
YSR2825FXTCKITC
118
YSR282CFXLTCKITC
118
YSR282CFXTCKITC
118
YSR286CFXLTCKITC
118
YSR286CFXTCKITC
118
YSR29FX25FXLTCKITC 118
YSR29FX25FXTCKITC
118
YSR29FX2CFXLTCKITC 118
YSR29FX2CFXTCKITC 118
YSR2CFX6CFXLTCKITC 118

CATALOG NO.
PAGE NO.
YSR2CFX6CFXTCKITC 118
YSR3125FXLTCKITC
118
YSR3125FXTCKITC
118
YSR3128LTCKITC
118
YSR3128TCKITC
118
YSR3129FXLTEL18
118
YSR3129FXTEL20
118
YSR312CFXLTCKITC
118
YSR312CFXTCKITC
118
YSR32FX29FXLTCKITC 118
YSR32FX29FXTCKITC
118
YSR3425FXLTCKITC
118
YSR3425FXTCKITC
118
YSR3428LTCKITC
117
YSR3428TCKITC
117
YSR3429FXLTEL10
118
YSR3429FXTEL12
118
YSR3431LTCKITC
117
YSR3431TCKITC
117
YSR3434FXLTEL34
117
YSR3434FXTEL36
117
YSR34FX25FXLTCKITC 118
YSR34FX25FXTCKITC
118
YSR34FX28FXLTCKITC 118
YSR34FX28FXTCKITC
118

CATALOG NO.
PAGE NO.
YSR34FX28LTCKITC
118
YSR34FX28TCKITC
118
YSR34FX29FXLTEL22
118
YSR34FX29FXTEL24
118
YSR38FX28LTCKITC
117
YSR38FX28TCKITC
117
YSR38FX29FXLTEL14
117
YSR38FX29FXTEL16
117
YSR38FX31LTCKITC
117
YSR38FX31TCKITC
117
YSR38FX34FXLTEL38
117
YSR38FX34FXTEL40
117
YSR3928LTCKITC
117
YSR3928TCKITC
117
YSR3929FXLTEL2
117
YSR3929FXTEL4
117
YSR3931LTCKITC
117
YSR3931TCKITC
117
YSR3934FXLTEL26
117
YSR3934FXTEL28
117
YSR3938FXLTEL42
117
YSR3938FXTEL44
117
YSR44FX29FXLTEL6
117
YSR44FX29FXTEL8
117
YSR44FX31LTCKITC
117

CATALOG NO.
PAGE NO.
YSR44FX31TCKITC
117
YSR44FX34FXLTEL30
117
YSR44FX34FXTEL32
117
YSR44FX34LTCKITC
117
YSR44FX34TCKITC
117
YSR44FX38FXLTEL46
117
YSR44FX38FXTEL48
117
YSR44FX39LTCKITC
117
YSR44FX39TCKITC
117
YSR4CFX6CFXLTCKITC 118
YSR4CFX6CFXTCKITC 118
YSV1014-G2
26
YSV1214-G1
26
YSV1418
26
YSV1C-FXB
115
YSV25-FXB
115
YSV26-FXB
115
YSV27-FXB
115
YSV28-FXB
115
YSV2C-FXB
115
YSV4C-FXB
115
YSV6C-FXB
115

INSTALLATION TOOLING SYSTEM


LUGS & SPLICES
One & Two
HOLE

Conductor
AWG

FLEX

Die

Color

Index

#8/#6
sol

#8

W8CVT
U8CRT

RED

49

#6

#6

W5CVT
U5CRT

BLUE

#4

#4

W4CVT
U4CRT

#3/#2
sol

T&B
Index
Code
(Flex)

TAPS
Thin-Wall C-taps
Run=Tap, AWG only

TAPS
Heavy Duty C-Taps
Run=Tap

TAPS
H-Taps
Run=Tap

Die

Color

Index

Die

Color

Index

Die

Color

Index

21

W4CVT

GRAY

U240

RED

240

U11T-1

GREEN

11

24

W2CVT

BROWN

10

UC

BROWN

GRAY

29

W25VT

PINK

12

UC

BROWN

UC

BROWN

W3CRT
U3CRT

WHITE

W26VT

BLACK

13

UC

BROWN

UC

BROWN

W27VT

ORANGE

14

UC

BROWN

UC

BROWN

W28VT

PURPLE

15

U997

ORANGE

997

U654

PURPLE

654

W29VT

YELLOW

16

U997

ORANGE

997

U654

PURPLE

654

U997

ORANGE

997

U654

PURPLE

654

U997

ORANGE

997

U654

PURPLE

654

#2

#2

W2CVT
U2CRT

BROWN

10

#1

#1

W1CVT
U1CRT-1

GREEN

11

1/0

1/0

W25VT
U25RT

PINK

12

42
(45)

2/0

2/0

W26VT
U26RT

BLACK

13

45
(50)

3/0

3/0

W27VT
U27RT

ORANGE

14

4/0

4/0

W28VT
U28RT

PURPLE

15

W29VT
U29RT

YELLOW

W30VT
U30RT

313

33

54
(62)

REFER
TO
CATALOG

UBGRT ORANGE

BG

U997

ORANGE

997

U654

PURPLE

654

16

U997

ORANGE

997

U654

PURPLE

654

WHITE

17

U1104

BROWN

1104 U1104 BROWN 1104

W31VT
U31RT

RED

18

U1104

BROWN

1104 U1104 BROWN 1104

350/
373

W32VT
U32RT

BLUE

19

U1104

BROWN

1104 U1104 BROWN 1104

444

W34VT
U34RT

BROWN

20

U1104

BROWN

1104 U1104 BROWN 1104

500/
535

U38XRT

PINK

L99

P1103

BLUE

1103

PYFR YELLOW

KR

600

U36RT

GREEN

22

P1103

BLUE

1103

PYFR YELLOW

KR

700

U38RT

PINK

400

P1103

BLUE

1103

PYFR YELLOW

KR

646

U39RT

BLACK

24

106

P1103

BLUE

1103

PYFR YELLOW

KR

750/
777

U44XRT

YELLOW

L115

800

P40RT

ORANGE

25

(115)

P1102

WHITE

1102

PYFR YELLOW

KR

1000

P44RT

WHITE

27

P1102

WHITE

1102

PYFR YELLOW

KR

250

300

350

500

750

4/0/
250
class
G&H
262/
250
class
I, K & M

71

87

(99)

INSTALLATION TOOLING SYSTEM


LUGS & SPLICES
One & Two
HOLE

Conductor
AWG

FLEX

Die

Color

Index

#8/#6
sol

#8

W8CVT
U8CRT

RED

49

#6

#6

W5CVT
U5CRT

BLUE

#4

#4

W4CVT
U4CRT

#3/#2
sol

T&B
Index
Code
(Flex)

TAPS
Thin-Wall C-taps
Run=Tap, AWG only

TAPS
Heavy Duty C-Taps
Run=Tap

TAPS
H-Taps
Run=Tap

Die

Color

Index

Die

Color

Index

Die

Color

Index

21

W4CVT

GRAY

U240

RED

240

U11T-1

GREEN

11

24

W2CVT

BROWN

10

UC

BROWN

GRAY

29

W25VT

PINK

12

UC

BROWN

UC

BROWN

W3CRT
U3CRT

WHITE

W26VT

BLACK

13

UC

BROWN

UC

BROWN

W27VT

ORANGE

14

UC

BROWN

UC

BROWN

W28VT

PURPLE

15

U997

ORANGE

997

U654

PURPLE

654

W29VT

YELLOW

16

U997

ORANGE

997

U654

PURPLE

654

U997

ORANGE

997

U654

PURPLE

654

U997

ORANGE

997

U654

PURPLE

654

#2

#2

W2CVT
U2CRT

BROWN

10

#1

#1

W1CVT
U1CRT-1

GREEN

11

1/0

1/0

W25VT
U25RT

PINK

12

42
(45)

2/0

2/0

W26VT
U26RT

BLACK

13

45
(50)

3/0

3/0

W27VT
U27RT

ORANGE

14

4/0

4/0

W28VT
U28RT

PURPLE

15

W29VT
U29RT

YELLOW

W30VT
U30RT

313

33

54
(62)

REFER
TO
CATALOG

UBGRT ORANGE

BG

U997

ORANGE

997

U654

PURPLE

654

16

U997

ORANGE

997

U654

PURPLE

654

WHITE

17

U1104

BROWN

1104 U1104 BROWN 1104

W31VT
U31RT

RED

18

U1104

BROWN

1104 U1104 BROWN 1104

350/
373

W32VT
U32RT

BLUE

19

U1104

BROWN

1104 U1104 BROWN 1104

444

W34VT
U34RT

BROWN

20

U1104

BROWN

1104 U1104 BROWN 1104

500/
535

U38XRT

PINK

L99

P1103

BLUE

1103

PYFR YELLOW

KR

600

U36RT

GREEN

22

P1103

BLUE

1103

PYFR YELLOW

KR

700

U38RT

PINK

400

P1103

BLUE

1103

PYFR YELLOW

KR

U39RT

BLACK

24

106

P1103

BLUE

1103

PYFR YELLOW

KR

(115)

P1102

WHITE

1102

PYFR YELLOW

KR

P1102

WHITE

1102

PYFR YELLOW

KR

250

300

350

500

750

4/0/
250
class
G&H
262/
250
class
I, K & M

646
750/
777

U44XRT
P44XRT-1 YELLOW

71

87

(99)

L115

800

P40RT

ORANGE

25

1000

P44RT

WHITE

27