Junlong Fang
Agricultural Engineering Research Center
Northeast Agricultural University
Harbin, P.R.China
jlIangneau.edu.cn
Fulu Wang
Agricultural Engineering Research Center
Northeast Agricultural University
Harbin, P.R.China
ican0512163.com
$EVWUDFW $EVWUDFW $EVWUDFW $EVWUDFW In this paper, we studied Heilongjiang Province and
other cold regions as the research object, invested the greenhouse
operation condition oI monitoring system. In the Northeast
Agricultural University, Greenhouse oI Horticulture Center, we
designed a Greenhouse environment monitoring system. This
research introduces virtual instrument technology and wireless
sensor network technology into the greenhouse environment
supervisory system. Using virtual instrument technology soItware
development platIorm LabVIEW, combined with ZigBee-based
wireless sensor network protocol (WSN) technology, designed
remote monitoring platIorm, to achieve control PLC via OPC
SEVER. Ultimately, complete the real-time remote monitoring oI
greenhouse.
.H\ZRUGV .H\ZRUGV .H\ZRUGV .H\ZRUGV :61 *UHHQKRXVH /DE9,(: 23& 6(9(5
5HPRWH PRQLWRULQJ
I. ,,,,1752'8&7,21 1752'8&7,21 1752'8&7,21 1752'8&7,21

Jilin Province and Heilongjiang Province are the mainly
agricultural provinces in China, which are located at the
coldly area (higher than north latitude 43). At present along
with the solar greenhouse expand rapidly, the region Irom
abroad and to design a large greenhouse. This area has
introduced Irom the overseas and independently designed
the massive sunlight greenhouse. AIter the investigation and
study, because oI the severe cold weather conditions in
winter, in the actual operation, there are many problems,
such as high energy consumption, high Iailure rate when
automatically operation, high maintenance costs. So that
greenhouse production mainly relies on human manual
management by experience |1-3|. Which is the chieI
obstacle limits the greenhouse crops high production, high
quality, the highly eIIective production. This article
constructs a superior machine supervisory system based on
the LabVIEW soItware platIorm, combined with wireless
sensor based on ZigBee technology to achieve the
greenhouse environment inIormation acquisition, display,
storage. By OPC SEVER oI NI DSC module, easy to
implement read-write on the PLC. So implement real-time
monitoring oI Iield devices and remote monitoring through
the WEB SEVER.
Fund Project: Harbin Science and Technology Agency Foundation
oI Returned Overseas(2010RFLXN020)
II. 000021,725,1* 21,725,1* 21,725,1* 21,725,1* 6666<67(0 <67(0 <67(0 <67(0''''(6,*1 (6,*1 (6,*1 (6,*1
The overall system design plan as shown in Figure 1. The
wireless sensor network is composed by temperature sensor,
the humidity sensor, the soil moisture sensor, the carbon
dioxide sensor and the illumination sensor that arrangement
in the greenhouse, Various sensors transIorm the non-
electrical quantity to electric quantity which changed along
with the environment parameter, Wirelessly transmitted to
the Ethernet gateway receiver, Then transmitted to the host
computer through the Ethernet interIace. PC running
monitoring soItware based on LabVIEW to achieve
RS232
PLC
Input Output
Limit switch Manual switch
Control cabinet
S
k
y
w
i
n
d
o
w
s
S
i
d
e
w
i
n
d
o
w
s
W
a
t
e
r
p
u
m
p
S
h
a
d
e
s
y
s
t
e
m
W
e
t
c
u
r
t
a
i
n
Wireles
s sensor
network
system
Printing,
display,
PC sever
Remote client computer
Fig.1- System block diagram oI the system
Internet
S
k
y
w
i
n
d
o
w
s
S
i
d
e
w
i
n
d
o
w
s
W
a
t
e
r
p
u
m
p
S
h
a
d
e
s
y
s
t
e
m
W
e
t
c
u
r
t
a
i
n
S
k
y
w
i
n
d
o
w
s
S
i
d
e
w
i
n
d
o
w
s
W
a
t
e
r
p
u
m
p
S
h
a
d
e
s
y
s
t
e
m
W
e
t
c
u
r
t
a
i
n

___________________________________
978-1-4244-8728-8/11/$26.00 2011 IEEE

environmental parameters display in real-time, database
storage, output print, parameter settings, alarms, historical
data query etc. Choose PLC as lower controller, ladder
programming is simple, the controller are high reliability in
the cold complex greenhouse environmental conditions.
III. 000021,725,1* 21,725,1* 21,725,1* 21,725,1* 6666<67(0 <67(0 <67(0 <67(0++++$5':$5( $5':$5( $5':$5( $5':$5( ,,,,17(*5$7,21 17(*5$7,21 17(*5$7,21 17(*5$7,21
Wireless sensor networks use NI WSN-3202. The
programmable NI WSN-3202 measurement node is a
wireless device that provides Iour +10 V analog input
channels and Iour bidirectional digital channels. The 18-
position screw-terminal connector delivers direct
connectivity to sensors, and the device oIIers a 12 V, 20mA
sensor power output that you can use to drive sensors
requiring external power. You can power the measurement
node with Iour 1.5 V, AA alkaline battery cells, with
operation up to three years on battery power, or you can
externally power the node with a 9 to 30 V supply (not
included). A 2.4 GHz radio is used to wirelessly transmit
data to the WSN gateway, where you can connect through
Ethernet to other network devices. You can conIigure the
WSN-3202 as a mesh router to increase network distance
and connect more nodes in your WSN system. You can
connect eight end nodes (star topology) or up to 36
measurement nodes (mesh topology) to a single WSN
gateway, with outdoor range up to 300 m with line oI sight
|4|.
Temperature sensor select SHT75, humidity sensor
select SHT75. The main perIormance indicators are:
temperature range -40 ~ 123.8; Accuracy + 0.3 (at
25); response time 8s;-power 20w (average); humidity
measuring range: 0-100 RH; accuracy oI + 1.8RH;
repeatability accuracy: + 0.1 RH; digital output. Soil
moisture sensor use 5TE. Light intensity sensors select
TBQ-6. The main perIormance indicators are: measuring
range 0-20million Lux; spectral range 400-700nm;
measurement error 2; supply voltage 12/24VDC; output
optional 4-20mA, 0-20mV. CO2 sensors used CGS-3100.
The main perIormance indicators are: measurement range 0-
2000ppm; measurement accuracy + 30ppm + 5 (0-50);
response time oI 30s; Power 9-18 VDC; the average
current consumption 50mA; digital output.
Lower machine controller selects OMRON PLC
CPM2AH 60CDR A, The controller has high reliability,
cost-eIIective, simple programming, design cycle is short
and so on. By calculating I / O, the system needs a total oI 29
inputs and 13 outputs.
IV. 7777+( +( +( +( 021,725,1* 021,725,1* 021,725,1* 021,725,1* 6<67(0 6<67(0 6<67(0 6<67(0 62)7:$5( 62)7:$5( 62)7:$5( 62)7:$5( '(6,*1 '(6,*1 '(6,*1 '(6,*1
The soItware design includes PC soItware design, and
slave ladder programming, this paper introduces the host
computer soItware design. PC monitoring interIace use NI
LabVIEW soItware programming. In order to Iacilitate the
operator to grasp the site conditions, design a simple, natural
and Iriendly supervisory control interIace, soItware
architecture shown in Figure 2, including user management
module, data acquisition module, parameter setting module,
the control output module, data processing and query
module.
Monitoring system login screen shown in Figure 3,
connected with the ACCESS database, users can be added,
landing rights and other management.
Fig.3- User login in screen
Real-time Data display screen shown in Figure 4, it can
display inIormation about the parameters oI greenhouse
environment, and by setting the upper and lower limits, to
achieve sound and light alarm management.
Fig.4- Graphical display oI sensor data Irom WSN network
User Login
Sensor
data
displa
y
Real-time monitoring
Fig.2- SoItware architecture
Status
display
and
control
oI
The
history
data and
curve
query
Alarm
record
inquiry
Paramet
ers
setting
Data Management
Remote
Publishin
g

Machine status display and control module shown in


Figure 5, by selecting the manual and automatic operation.
By using this way, virtual instruments achieve remote
control oI a variety oI Iield devices
Fig.5- Device operation and control panel
Using database access toolkit LabSQL, users access the
database by MircosoIt ADO database access language.
Monitor system storage the Real-time data such as
temperature, humidity, light, carbon dioxide concentration
and the state oI the actuator into the Access database,
operator can query the data by date in query interIace. Front
panel shown in Figure 6.
Fig.6- Historical data query
V. COMMUNICATION BETWEEN PC AND PLC
NI LabVIEW soItware can communicate with any
programmable logic controller (PLC) in a variety oI ways.
OLE Ior Process Control (OPC) deIines the standard Ior
communicating real-time plant data between control devices
and human machine interIaces (HMIs). OPC Servers are
available Ior virtually all PLCs and programmable
automation controllers (PACs). In this tutorial, learn how to
use LabVIEW to communicate with a networked PLC using
OPC |5|.
The program uses the traditional serial based PLC
OMRON CPM2AH. First complete write the ladder
program by Omron PLC programming soItware CX-
Programmer, then connects the PC to PLC through the
RS232 serial cable, power on, loads the ladder program to
PLC. Then set the NI OPC server. Select Start~program~
National Instruments ~NI OPCServers~ NI OPCServers.
Start the NI OPC Server, Shown in Figure 8. Right-click the
device area to create channel, device drivers select OMRON
host link, and gradually select Next to complete the set.
Right click the channel that just created, select Create
devices, Enter the device name CPM2AH. Then in the right
box, as shown in leIt-click, add tag, enter the tag name and
address, conIigure PLC address, Figure 7. OPC server
settings basically completed.
Fig.7- OPC SEVER setting and address oI the PLC
LabVIEW implies a NI oI OPC Client in DataSocket,
OPC Client communicate with OMRON through the OPC
Sever, interaction data. Here's how to use OPC SEVER to
establish a data connection with the PLC. Generated the
needed communicate controls in the Front Panel; the
controls type oI data should be consistent with the data type
in the OPC. Right click the control, pop-up shortcut menu,
select Properties ~ Data Binding ~ Data Binding select ~
DataSocket, set the appropriate access type and the path,
this will connect Iront panel controls to the PLC address to

realize the PLC control, LabVIEW program is running,


change the value oI the Iront panel controls, data changing
can be observed corresponding to the address on the PLC in
the OPC SEVER; The value oI the variable in LabVIEW
will also change corresponding to the PLC address. At this
point, the PC and PLC achieve real-time communication
based OPC SEVER.
VI. REMOTE MONITORING IMPLEMENTATION
By using the LabVIEW Web server, LabVIEW
program can be posted on the web, the local or remote client
computers can browse or control remote panel, to achieve
remote control oI greenhouse environment equipment.
Using the Web publishing tools, select Tools / Options,
completing the Web server-related settings and the
publishing oI LabVIEW program, shown in Figure 11,
setting Web Server: ConIiguration; Web Server: Visible VI;
Web server: browser access. By setting the Tools / Web
Publishing Tools dialog box, you can publish program in
memory on a web page, the browser client. Users can
remotely monitor and control |6|.
According to the diIIerent soItware installed on the
client, clients have diIIerent methods to access the remote
panels. For example, browse Iront panel on the Web page;
browse HTML Iiles on the Web page; remote monitor Iront
panel in LabVIEW; remote monitor use LabVNC panel.
This paper chose to use a Web browser in a web page
to operator the remote panel. Note that the client computer
should install the Iree LabVIEW Run-Time Engine,
installation space size about 90M. In the LAN, the remote
panel address Iormat is: http:// computer name: port /
viname.htm; in the Internet, the remote panel address Iormat
is http://ip address: port/viname.htm.
When the remote panel appears in the browser, you can
right-click the mouse. In the pop-up menu, you can request
VI control, shown in Figure 8. When multiple clients
monitor the server side simultaneously, sever can be
monitored by multiple simultaneous, but only one client has
control right, the other should wait to obtain control aIter
post-release.
Fig.8- Remote Monitoring InterIace
In the Web server, by using the Tools / Remote Panel
Connection Manager, you can view and control the state and
computer's connection inIormation link to the client.
VII. &&&&21&/86,21 21&/86,21 21&/86,21 21&/86,21
Using advanced NI hardware and soItware platIorm, we
developed a cold greenhouse control system that reliable,
stable operation in a very short period oI time. Through
theoretical analysis and experiments conIirmed that the
system can eIIiciently capture the greenhouse environmental
parameters, including temperature, humidity, light intensity,
and has strong adaptability, security and reliability. The
system has a very large practical value in complex
Greenhouse Environmental monitoring.
REFERENCES
|1| Shigang Cheng. Modern greenhouse environment control |J|.
Agricultural Equipment & Technology. 2004,30(6):7-9
|2| Peng He. Greenhouse environmental control technology development
and application |J|. Sensors World. 2002,8(2):8-11
|3| Zhiquan Zhao. Israel Modern Agriculture Development |J|. Jiangsu
Science and Technology InIormation, 2007 (3) :33-34
|4| W S N Programmable Analog Input Measurement Node,
http://www.ni.com/pdI/products/us/catwsn32xxprog.pdI.2010.03
|5| Connect LabVIEW to Any PLC Using OPC sever,
Itp://Itp.ni.com/pub/devzone/pdI/tut10860.pdI.2009.12
|6| How to import web server in LabVIEW.
http://zone.ni.com/wv/app/doc/p/id/wv-2012.2009.03

Das könnte Ihnen auch gefallen