Features
Explosion-proof for hazardous locations High accuracy Remote, local or ambient sensing UL, CSA & ATEX approved NEMA 4, 7, 9 & IP65
Temperature
Series T1X, T2X, L1X
L1X T2X
Applications
Oil & gas Heat tracing Printing machinery Compressors Process equipment Machine tools and industrial equipment
General Specifications*
Accuracy: Switch: Single Setting: 1% of mid-60% of full range. At constant ambient +/- 0.5% of full scale. One (1) single pole double throw (SPDT) circuit. Two (2) independent single pole double throw (SPDT) circuits. All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. 304 stainless steel Single: 3-pin terminal strip Dual: 6-pin terminal strip AC value at 75% power factor 10 amps 125, 250 volts AC, 3 amps 480 volts AC. Automatically reset by snap-action of switch. Designed for hazardous locations: Class I, Division 1 & 2 NEMA 4, 7, 9 & IP65 tamper-proof external adjustment, enclosed terminal strip. UL (standard): CSA (standard): Local Mount: Bulb & Capillary: Approvals: Immersion length 2-1/16 inches 6 and 12 foot length standard. Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under Temperature indicating and regulating equipment, for use in hazardous locations, Class I, Groups B, C and D; Class II, Groups E, F and G. File No. E58658, Guide No. XBDV File No. LR34556, Guide 400-E-O.8. Class 4868. EX models are ATEX certied per ISSeP 03 ATEX 121 & maked as follows: CE 0081 II2 GD EEx d IIC T6 T85 C See product congurator Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. For thermowels, split nuts and union connections, see accessory pages. Single - approximate 3.0 lbs. Dual - approximate 7.0 lbs.
ATEX (optional):
Enclosure/Housing:
Wiring Code
Lead Normally Closed Common Normally Open Circuit #1 Blue Purple Red Circuit #2 Orange Brown Yellow
Wiring Diagram
NO (Red) C (Purple) NC (Blue)
T
Product Configurator
Hermetically Sealed
H Hermetically sealed limit switch option - Class I, Division II (requires AA, CC or HH limit switch)
Example
-HH
251
-12
-A
Options
-RD -EX -Sxxx Manual reset (must use when selecting G limit switch option) 3 Only available on T2X ATEX certication Factory pre-set (consult factory)
Sensing Type
T L Remote bulb & capillary Local mount
Wetted Material
Blank S Brass sensor 304 stainless steel (6ft capillary for remote sensing models)
Set Point
1 2 Single setpoint (SPDT) Dual setpoint (2 SPDT) 1
Blank = 6 foot capillary 12 ft capillary 25 ft stainless steel capillary with armor (use with the A options)
Limit Switch
-H -B -G -J -L -M -S -GH -AA -CC -HH
1
10 amps @ 125/250 VAC; 3 amps @ 480 VAC (standard) 10 amps @ 125/250/480 VAC; 2 amps @ 600 VAC; 0.05 amps @ 125 VDC; 0.03 amps @ 250 VDC 10 amps @ 125/250/480 VAC; 2 amps @ 600 VAC; 0.4 amps @ 125 VDC; MANUAL RESET (only available for T2X) 3 10 amps @ 125/250 VAC; 3 amps @ 480 VAC (with elastomer boot) 15 amps @ 125/250/480 VAC; 0.03 amps @ 125 VDC; 0.02 amps @ 250 VDC 10 amps @ 125/250 VAC; 3 amp @ 480 VAC; 0.5 amps @ 125 VDC; 0.25 amps @ 250 VDC 15 amps @ 125/250/480 VAC; 0.05 amps @ 125 VDC; adjustable differential 4 1 amp @ 125VAC; gold contacts Hermetically sealed; 4 amps @ 125/250 VAC Hermetically sealed; 10 amps @ 125/250 VAC Hermetically sealed; 5 amps @ 125/250 VAC
Temperature Range
Range Low 154 251 351 601 603 -50F +50F High +150F +250F Low
Adjustable Range
Media Temperature Limit (Proof) High +24C +60C +93C Low -100F -100F -100F -100F -100F -100F 0F High +250F +250F +250F +400F +250F +400F +500F Low -73C -73C -73C -73C -73C -73C -18C High +121C +121C +121C +205C +121C +205C +260C
Differential (Approx.) 2
F
1 to 3 1 to 3 1 to 3 6 to 9 1 to 3 6 to 9 3 to 6
C
.5 to 1.6 .5 to 1.6 .5 to 1.6 3.3 to 5.0 .5 to 1.6 3.3 to 5.0 1.6 to 3.3
Not available with local mount version. 2 Changing limit switch will effect deadband; See sales drawing 3 When selecting the manual reset option on dual setting switches (T2X), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. Only available with T2X.
When selecting the S adjustable differential limit switch option on a dual setting switch (T2X), a standard H switch will be paired with an S switch. Dual S pricing will apply.
See Barksdales Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0022-G 11/08 2008 Printed in the U.S.A.