Date; 02.09.2012 M/S PRATAP UNIVESITY CHANDWAJI JAIPUR


Subject: - Supply and Erection & Commissioning of:1. Reverse Osmosis based Packaged-drinking Water Treatment Plant Capacity 1000 LPH. 2. . Reverse Osmosis based Packaged-drinking Water Treatment Plant Capacity 750 LPH. 3. Reverse Osmosis based Packaged-drinking Water Treatment Plant Capacity 500 LPH. Kind ; RAJISTRAR SIR This is with reference to the discussion held with your good self regarding Your requirement of water treatment plant for packaged drinking. We thank you very much for your kind interest in our range of products. We acknowledge with thanks the receipt of your enquiry for the above subject matter. We are also pleased to introduce ourselves as one of the leading company in the field of water Treatment, Filling systems and all other relevant machines and components. We have designed the plant as per your requirement and shall meet all the Indian standard norms as per IS: 14543 for packaged drinking water. We have included all the necessary equipments to give you a well-engineered and reliable Water Treatment for Packaged Drinking Water. We have earned a high reputation in the industry for our quality, design and performance. Our technical expertise is always at your disposal to assist you in operating and maintaining systems for years to come. The enclosed bid index forms part of our detailed offer. We hope you will find our offer and business terms in the line of your requirement. Should you require any further clarifications/information we shall be glad to furnish the same. Yours truly, For WANTECHRO, Email : wantechro@gmail.com

Raj Choudhary 09335064768, 09235503333, 9415178237

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

BID INDEX

ANNEXURE I ANNEXURE II ANNEXURE III ANNEXURE IV

WATER TREATMENT PLANT SCHEDULE OF EXCLUSIONS & TERMINATION POINTS PRICE SCHEDULE COMMERCIAL TERMS & CONDITIONS

ANNEXURE I

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

WATER TREATMENT PLANT BASED ON REVERSE OSMOSIS TECHNOLOGY Capacity: 1,000 Lts. Per Hour (1 m3 per Hour)

BASIS OF DESIGN AND CAPACITY OBJECT: To commission a Reverse Osmosis System feed water 1000 liters of low TDS water per hour. ASSUMPTIONS: No. Of working days: No. Of working hours: Capacity utilization: INPUTS (Raw water Quality): 360 days 10 hours 91-95%

Total Dissolved Solids: OUTPUT (Treated Water Quality):

< 1000 PPM (Max)

Total Dissolved Solids: < 50 PPM FINAL OUTPUT TDS : As Per requirement

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.
TECHNICAL SPECIFICATIONS Flow Rate : Feed Water : 2000 LPH Treated Water : 1000 LPH Reject Water : 1000 LPH 1 RAW WATER PUMP Purpose Specifications

To feed the Dual Media Filter at pressure more than 2.0 bar, which is min. operating pressure for filter. a) MOC : CI b) Type : Horizontal Centrifugal c) Flow Rate : 2000 liters per hour d) Head : 35 m e) Power Required: 0.74 KW f) Electrical : 440 V, Three phase , 50 hz g) Cycle : 2900 rpm h) Make : Kirloskar i) Quantity : 1 No.

DUAL MEDIA FILTER Purpose Specifications

To remove the total suspended solids, dirt , iron and reduce silt density index which can foul the membranes Vessel : a) Make: Wave Cyber/Pentair b) Material of Construction : FRP c) Diameter : 350 mm d) Height : 1625 mm e) Testing Pressure : 10 kg/cm2 f) Opening : Top & Bottom g) Quantity : 1 No. Valve : a) Make: Initiative, India b) Material of Construction: Noryl c) Type : Multiport Single lever value d) Size : 1.0 inches e) Maximum Flow Rate : 4000 LPH f) Working Pressure : 2-4 Bar

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.
g) Working : Down-Flow Media : Mixed bed sand media consisting of the following i) Gravel ii) Pebbles iii) Quartz Sand iv) Anthracite Average Porosity 50 micron particulate size Bed depth: 600 mm Pipelines & Accessories: Pipe of PVC 10 Bar tested pressure 3 ACTIVTED CARBON FILTER Purpose Specifications

To remove the total color, smell, odur, from the water. Vessel: a) Make: Wave Cyber/Pentair b) Material of Construction: FRP c) Diameter: 350 mm d) Height: 1625 mm e) Testing Pressure: 10 kg/cm2 f) Opening: Top only g) Quantity: 1 No. Valve: a) Make: Initiative, India b) Material of Construction: Noryl c) Type: Multiport Single lever value d) Size: 1.0 inches e) Maximum Flow Rate: 4,000 LPH f) Working Pressure: 2-4 Bar g) Working: Down-Flow Media: Mixed bed sand media consisting of the following i) Gravel ii) Pebbles iii) Carbon Average Porosity 50 micron particulate size Bed depth: 600 mm Pipelines & Accessories: Pipe of PVC 10 Bar tested pressure Testing cock & pressure gauges at inlet-outlet of system

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

DOSING SYSTEM Purpose Specifications

To dose antiscalant chemical to protect the scaling formation on RO membranes. a) MOC: PP b) Capacity: 5 LPH c) Pressure: 7 Bar d) Qty.: 1 No. e) Make: Seko/ Etatron DS, Italy To remove the fine particles up to 05 microns and reduce silt density index levels to acceptable level. Cartridge Filter & Housing Housing : a) Make: Pentair India b) MOC of Housing: PP c) Length : 20 d) Diameter: 4.5 e) Quantity : 1 No. Cartridge : f) Make : Filtermation g) Cartridge MOC : Polypropylene h) Length: 20 i) Diameter : 2.5 j) Quantity: 1 no. k) Micron rating: 05 micron

MICRON FILTER Purpose Specifications

HIGH PRESSURE PUMP Purpose To feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery. Specifications a) MOC : Stainless Steel b) Type : Vertical Multistage c) Flow Rate : 2000 liters per hour d) Head : 110 mwc e) Power Required : 1.5 KW

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.
f) Electrical : 440 V, three phase , 50 hz g) Cycle : 2900 rpm h) Make : Sumo/ CRI Eqv. 7 RO MEMBRANE Purpose

Specifications

To remove the major part of TDS upto 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and recovery. a) Type: Spiral Wounded b) Diameter of Membrane: 4.0 inch c) Length of Membranes: 1 Mt. d) No. of Membranes : 4 e) Recovery per Membrane: 15-17% f) Salt Rejection per Membrane: 98-99% g) Make of Membranes: Hydronautics/Dow, USA h) System Recovery: 50 % To pack Reverse Osmosis Membranes and operate at high pressure up to 300 psi a) MOC : ss Composite b) Diameter of Pressure Vessel : 4.2 inch c) Length of Pressure Vessel : 2.3 m d) No. Pressure Vessels : 2 e) No. of Membrane per Vessel : 2 f) Make : Wave Cyber/Pentair g) Position : Horizontal, Series h) Arrays : 1 No.

RO PRESSURE TUBE Purpose Specifications

RO CLEANING SYSTEM Purpose We provide a flushing system, which shall help to clean the membrane and get rid of the floulants that get deposited on the membranes. Specifications a) Flushing Time : 15 minutes b) Flushing Media : Treated Water / Chemical c) Flushing Tank Size : 300 L d) Tank MOC : HDPE e) Flushing Pump : SS Pump will be used

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.
f) Semi automatic with two ball valves operation 10 ELECTRICAL PANAL Purpose Specifications

A control panel is provided as a safety measure for the pumps & other electrical items. a) Complete Starters, Overload relays, and singlephase preventor for Pump. b) Voltmeter, Ammeter, MCBs, indicating lights c) Push Buttons d) Rocker Switches for Dosers e) Incomers, Auto-Manual Switches

11

INSTRUMENTATION Purpose

Specifications

a) Flow Meter : To measure the online flow of water b) TDS Meter : To measure the online TDS of water c) Low Pressure Switch : To protect RO pump from dry running e) High Pressure Switch : To protect RO pump from back pressure f) Pressure Gauges : For calculate ^P for each unit in RO system Rota Meter : Quantity : 2 Nos.( permeate & reject line) Range: 3.0 cu.m. per hour Make : Flow star / Aster, India Digital TDS meter : Quantity : 1 No.(permeate line) Range : 0 500 PPM Make : Aster, India Pressure Switch : Quantity : 2 No.(Low & High) Range : 0-450 psi Make : Indfos, India Pressure Gauges : Quantity : 6 No. Range : 0 7 bar

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.
Dail Size : 6 inches Type : Bourdon Make : Gluck/Guru, India

12

TREATED WATER TANK a) Capacity b) MOC c) Make d) Quantity : 2000 Liters : SS 304 : , India : 1 No

13(c) pH DOSING SYSTEM Purpose Specifications

To dose Sodium Bi-carbonate for enhance product water pH. a) MOC: PP b) Capacity: 5 LPH c) Pressure: 7 Bar c) Pressure: 7 Bar d) Qty.: 1 No. e) Make: Seko/ Etatron DS, Italy

14

PLUMBING & FITTINGS a) Valves, pipelines RO module is in upvc, and SS304, after MF till the permeate line termination point. b) NRV's, pressure relief valves, wherever needed c) The System will be on common MS base frame

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

UTILITIES:-S
We would require:

Stable Bore well supply to give 2500 LPH. Raw water storage tank for 2 hr. storage. Argon Gas Labour & Helper. Power: 4.75 KW Plant Area: 15 Ft. (L) x 7 Ft. (B) x 10 Ft. (H) Proper shed for the plant. Civil work as per recommendation. 1/3 Phase Electrical points. Stable electricity supply.

ANNEXURE- V SCHEDULE OF EXCLUSIONS & TERMINATIONS


SCHEDULE OF EXCLUSIONS 1. All civil works, such as plant building, shed, foundation of equipments, bolts, pipe Supports, supporting structures, platforms and mass concreting.

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.
2. 3. 4. 5. 6. 7. Construction of drain sump and drain channels and any special lining. Plant area, building illumination, ventilation and earthing. Supply of power to motors and water. Raw water storage tank and pump, product water storage tank and pump. All pipe work beyond our termination Points. Layout of the equipments, piping, cabling and erection has been considered as per our standard layout design. All piping, cabling, erection etc. required, as per client's specific requirement subsequent to order finalization shall be at extra cost. Design codes standards, features, specifications and supply of all items, quantity, make etc. shall be as per our standard or as per the scope & specifications finalized at the time of order. Any changes in design codes, standards, features, specifications, quantity, makes, addition of items other than specified in the order shall be extra cost which shall be finalized before the same is supplied. Transit insurance shall be client's responsibility. Insurance has been arranged by us on behalf of the client for their convenience.

8.

9.

10. All equipments, work and services not specifically mentioned as forming part of our offer. 11. Erection, commissioning and handling over of the plant shall be considered to have been completed as described below: 11.1 The plant shall be considered once the equipments, media, interconnecting piping, Instruments and accessories essential to the plant operation are in place. Minor job completions, not affecting commissioning, shall not be the reason to consider it not completed. The plant shall be considered as commissioned on attaining the required water output and quality. Minor corrections, modifications like leakages; component rectification etc. not affecting commissioning shall be completed later. The plant shall be considered as handed over to client once the commissioning runs/ cycles have been completed as referred above.

11.2

11.3

TERMINATION POINTS 1. Inlet of Multigrade Sand Filter (MSF) of Reverse Osmosis Plant.

2. Permeate outlet of Reverse Osmosis Plant. 3. Reject of Reverse Osmosis Plant. 4. Overflow, backwash, drain of all vessels of R.O. Plant.

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.
5. Inlet of all measuring tanks. 6. Inlet of Water treatment plant. 7. Outlet of Water treatment plant. 8. Power Terminals to control panel. CIVIL WORK REQUIREMENT Being a set- up of food industry, the plant and machinery require utmost hygienic conditions : Water Treatment Plant Flooring & Ceiling : Proper Shed with dust proof atmosphere. : Colour should be white. The floor should be properly tiled. * There is no exhaust and is completely pollution free plant.

ANNEXURE V

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

PRICE SCHEDU
S. No. DESCRIPTION REVERSE OSMOSIS Plant (1,000 lts/hr. capacity) as stated in Annexure-I REVERSE OSMOSIS Plant (750 lts/hr. capacity) as stated in Annexure-I REVERSE OSMOSIS Plant (500 lts/hr. capacity) as stated in Annexure-I SS TANK 1000Ltr.Storage QTY. RATE (Indian Rs.) AMOUNT (Indian Rs.)

1.

2,78,900.00

2,78,900.00

2. 3. 4.

2,30,900.00 1,88,500.00 55,000.00

2,30,900.00 1,88,500.00 55,000.00

5. 6. 7. 8. 9.

Pipes & fintting upvc pipes

1lott

Extra charges

Extra charges

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

ANNEXURE VI COMMERCIAL TERMS & CONDITIONS


PRICE BASIS: The prices of machines/ plant are net and Ex-factory KANPUR and Delhi

Exclusive of Packing. @ 2% Exclusive of freight.

TAX & DUTIES: C.S.T. 2% against form C else 13.5% OCTROI & INSURANCE: At actual. ERECTION & COMMISSIONING CHARGES: All the To & Fro Traveling & all the lodging, boarding, Hotel charges of our Engineer shall be borne by the client. TERMS OF PAYMENT:

70% Advance alongwith the Purchase Order. 30% Against Performa Invoice before dispatch.
TRAINING: Training at Site in Factory. Training duration minimum 5 working days. All the expenses during the training period shall be borne by the client. DELIVERY: We shall supply the Plant within 15 20 DAYS from the date of receipt of Purchase Order and advance as per terms. VALIDITY: This offer is valid for 1 month.

GUARANTEE/ WARRANTY:

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.
The equipments supplied are guaranteed for a period of one year from the date of commissioning. Equipment Guarantee is valid against defective workmanship and/or poor performance of the system only. Our liability is limited to repair or replace the same and subject to any wear & tear or supply of consumables and spares due to regular operation of the system.

Cancellation of P.O.
In any case due to whatsoever reason if the P.O is cancelled the advance paid will be forfeited and no claims will be entertained. STATUARY VARIATION: Any change in Govt. duties, levies, taxes or policies having direct effect on our above quoted prices will be at client's account. Kindly sign the duplicate as your acceptance of our offer and terms.

For WANTECHRO ,
111/337 ASHOK NAGAR KANPUR.

Raj Choudhary 09335064768 ,9415178237, 9235003333,

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

ANNEXURE I
REQUIREMENT :
You have indicated the requirement of Packaged Drinking Water Plant (REVERSE OSMOSIS) of 750,500, Ltrs./hr.

PROPOSAL :
Based on the above, we have envisaged the following Packaged Drinking Water Plant scheme to cater to your requirement.

Sand filter Storage tank


Filling Station
MULTIGRADE SAND FILTER :

Carbon filter Ultraviolet

Micron filter Micron filter

H.P.P. R.O.

The raw water shall be subjected to coarse filtration on being passed through Multigrade sand filter, so as to get outlet water quality.

ACTIVATED CARBON FILTER : The raw water shall be subjected to coarse filtration on being passed through Activated Carbon filter, so as to get outlet water quality of Free for Chlorine and smell.

R.O. FEED WATER PRESSURIDSATION: Since the R.O. Plant work on higher pressure because the Osmotic, therefore the feed water to R.O. is first pressurized by pumping it through a high pressure pump. DESALATION BY R.O. :

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

The pressurized water from the high pressure pump shall be feed to the R.O. Membranes held in R.O. Tubes. Wherein there will be a rejection of the dissolved solid and the permeate you will get will be with reduced dissolved solid. Water shall be taken in a breakup tank and shall be pumped to point of use after necessary correction for various applications.
The Mineral water shall than be confirming to the following specification :

pH T.D.S. Odour Conductivity Appearance Turbidity Chromium Arsenic Calcium Magnesium

: : : : : : : : : :

7.0 0.2 80 to 150 PPM Colourless 62 PPM to 104 PPM Clear Less < 0.4 NTU Less then 0.006 mg/L Less then 0.002 mg/L Less then 8.0 mg/L Less then 5.0 mg/L

ANNEXURE II,500ltr SCOPE OF SUPPLY

The Plant shall consists of the following equipment : Sl. No. Item Qty.
Description

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

1. 2. 3. 4.

Raw Water Pump

1 No. C.I. Monoblock 1 No. Vessel with Frontal pipe valves media etc. 1 No. Activated Carbon Vessel. 1 Set Housing with cartridge of 5 micron rating.

Dual Media Filter Activated Carbon Filter Unit Micron Filtration Unit High Pressure Pump R.O. Housing R.O. Membrane Flow Indicators

5. 6. 7. 8.

1 No. S.S. Vertical Multistage Pump . 2 No. SS Pressure Vessel altima make. 2 No. TFC Spiral Wound Hydranautics, USA. 1 Set membrane

Online Digital indicator for Draine & Re circulation.

9. 10.

TDS Meter Electrical Control

1 No. On Line TDS indicator 1 No. For semi-auto operation of unit with inter locking.

WANTECH RO
ROSYSTEM&PLANT ISO : 9001- 2008.

Tin No.09537515279

Ph. 09235-503333 09415178237 111/337 Ashok Nagar, 80, Feet Road Kanpur (near Post Office). Email : wantechro@gmail.com.

ANNEXURE -750ltr. SCOPE OF SUPPLY

The Plant shall consists of the following equipment : Sl. No. 1. 2. 3. 4. Item
Raw Water Pump

Qty. Description 1 No. C.I. Monoblock 1 No. Vessel with Frontal pipe valves media etc. 1 No. Activated Carbon Vessel. 1 Set Housing with cartridge of 5 micron rating.

Dual Media Filter Activated Carbon Filter Unit Micron Filtration Unit High Pressure Pump R.O. Housing R.O. Membrane Flow Indicators

5. 6. 7. 8.

1 No. S.S. Vertical Multistage Pump . 3 No. SS Vessel altima make. 3 No. TFC Spiral Wound membrane. 1 Set Online Digital indicator for Draine & Re circulation.

9. 10.

TDS Meter Electrical Control

1 No. On Line TDS indicator 1 No. For semi-auto operation of unit with inter locking.