Sie sind auf Seite 1von 36

Short Form Programmable Logic Controllers

09/2008

The Panasonic PLC range


Advantages of PLC control
PowerfuL Hardware SoLuTionS
Panasonic PLCs offer an outstanding price-performance ratio which incorporates numerous functions into a very compact body. Even in the smallest size they provide a powerful instruction set which allows the system to handle demanding tasks such as analog control, networking and positioning control.

innovaTive Programming SofTware


Our PLC programming software was one of the first on the market conforming to the international standard IEC 61131-3. Numerous libraries that incorporate a lot of our know-how ensure the reusability of ready-made functions and function blocks and save time for programming and debugging.

Operation speed in s
1.0

(Basic instructions per one step)

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.03

I/O Points

fP2
0.35s
A multifunctional PLC with a compact body. The FP2SH can execute a program of 20k steps in a scan time of 1ms.

fP2SH
0.03s

1600

384

The smart controller of the next generation. Mediumscale functionality provided in small size.

fP (Sigma)
0.32s

128

As slim as 25mm, this pocketsize controller can be installed anywhere.

fP0
0.9s

fP-X
0.32s

Advanced compact model with high speed, large capacity and multifunction capability.

fP-e
14
Timer, counter, temperature controller, HMI and PLC in one unit.

0.9s

09/2008

Long-Life QuaLiTy
As with all Panasonic products, the PLCs undergo extremely rigorous testing during development that far exceeds the demands that will actually be placed on them. This is a guarantee for the long life of the product in the application.

BenefiT from good ServiCe


In addition to a comprehensive PLC range, Panasonic also offers the high-quality care demanded from a service-oriented company certified according to ISO 9001. Highly trained application engineers can provide custom designed systems. The sales staff regularly participates in hardware and software training courses.

ConTenTS:
Selection of products . . . . . . . . . . . . . . . . . . . . . . . . 25 Networking technology . . . . . . . . . . . . . . . . . . . . . . . 67 FP0 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 812 FP (Sigma) series . . . . . . . . . . . . . . . . . . . . . . . 1315 FP-X series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1619 FP-e series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2021 FP2 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2228 FP Web-Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 FP Modem-EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Programming software FPWIN Pro . . . . . . . . . . . . . . 31 FP OPC server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 FP Data Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Control CommX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 GT series operator terminals . . . . . . . . . . . . . . . . . . . 35

09/2008

The Panasonic PLC range


Selection of products
model fP-e fP0 fPS (Sigma)

PLC + Display + Switch All-in-one controller with six functions


Mountable in a 48mm square cut in a panel 14 I/O points (input: 8, output: 6) Can serve as a temperature controller with a thermocouple input

Pocket-size ultra-compact controller Ideal for use in extremely narrow spaces


Wide selection of program capacity from 2.7k to 10k steps Wide selection of the number of I/O points from 10 to 128 Up to 24 thermocouple inputs connectable for multipoint temperature control Programs rewritable during RUN mode without stopping production

High performance ultra-compact controller Reliably supports the control of higher speed equipment with more functions featured
Excellent basic performance, including program capacity of 32k steps, operation speed of 0.32s/step, and 384 I/O points Built-in two-axis 100kHz pulse output capable of interpolation control Positioning units capable of controlling network servomotors Can be equipped with up to three ports for general-purpose serial communication Compatible with PROFIBUS, DeviceNet, and other open field networks

Features

Motor control by the built-in pulse output Heater control by the PWM output Serial communications by the RS232C/RS485 port

CPU (control unit) model Maximum controllable I/O points Connectable expansion units Program capacity Comment memory Operation speed Data register Internal relay Ethernet PROFIBUS DP DeviceNet CANopen Modbus-RTU Network compatibility CC-Link Computer link (MEWTOCOL) General-purpose serial (nonprocedural) PLC link W W0 W2 VE Remote I/O (MEWNET-F) S-LINK Built-in pulse output Motor control Positioning unit PWM output High-speed counter
Analog measurement

Basic type 14 points N/A

Thermocouple input type 12 points

C10/C14/C16 106 to 112 points

C32 128 points 3 units

T32 128 points

C24 376 points

C28 380 points 7 units (Right: 3 Left: 4)

C32 384 points

2.7k steps N/A 0.9s/step (basic instructions) 1660 words 1008 points (63 words) A (with FP Web-Server 2) N/A N/A N/A A (RS485 type) N/A A (Tool port, COM port) A (COM port) N/A N/A N/A N/A N/A N/A 2 axes/10kHz N/A 2 points/1kHz/1000 resolution 4 ch/10kHz N/A N/A N/A 2 ch (thermocouple) 4 ch/5kHz 2 axes/5kHz

2.7k steps

5k steps N/A

10k steps

32k steps A (Built-in memory) 0.32s/step (basic instructions) 32,765 words 4096 points (256 words) A (with FP Web-Server 2) A (Slave, FNS unit; master FMU) A (Slave, FNS unit; master FMU) A (Slave, FNS unit; master FMU) A (RS485 communication cassette) A (Slave, CC-Link unit) A (Tool port, communication cassette) A (Tool port, communication cassette) N/A A (RS485 communication cassette) N/A N/A A (64-point slave stations, I/O link unit) A (S-LINK unit) 2 axes/100kHz (Transistor output type) 2-axis/4-axis type unit, up to 16 axes 2 points/12kHz/1000 resolution (Transistor output type) 4 ch/50kHz 8 ch/unit 4 ch/unit 2-ch input and 1-ch output mixed unit

0.9s/step (basic instructions) 1660 words 6144 words 16,384 words

1008 points (63 words) A (with FP Web-Server 2) Slave N/A N/A N/A A (Slave, CC-Link unit) A (Tool port, COM port) A (COM port) N/A N/A N/A N/A A (64-point slave stations, I/O link unit) A (FP0-SL1 control unit) 2 axes/10kHz (C16,C32,T32) N/A 2 points/1kHz/1000 resolution (C16, C32, T32) 4 ch/10kHz 8 ch/unit 4 ch/unit 2-ch input and 1-ch output mixed unit

Voltage/current input Voltage/current output Temperature input

8 ch thermocouple unit, 6 ch RTD unit A (T32 only) Compatible with RS485 using C-NET adapter

8 ch thermocouple unit, 6 ch RTD unit A Potentiometer input: 2 points

Calendar timer (clock function) Others


N/A: Not available A: Available

A (calendar timer type) Front panel switch input: 8 points

09/2008

model

fP-X

fP2

fP2SH

High performance compact terminal-block type controller Wide selection of add-on cassettes allows space-saving use of the controller for a variety of purposes Features
Up to three add-on cassettes can be attached to the top of the control unit. The unit is of the terminal block type, but is space-saving and allows a variety of applications. Ethernet cassette available for data collection Built-in four-axis pulse output. Two axes for linear interpolation Comment memory for simple maintenance work USB port for direct connection to a PC

Standard of the compact medium-scale class Loaded with positioning and networking functions controller for a variety of purposes
Compact body of 140 x 100mm (WxH) (five modules) Wide selection of positioning units RTEX: Compatible with wire-saving network servomotors Multifunction type: Super-quick startup in 0.005ms Interpolation type (to be released): Three-axis helical interpolation, two-axis synchronization Compatible with Ethernet, CANopen, PROFIBUS, DeviceNet, CC-Link, and various other open field networks C1 C1D 2048 points 32 units (when the H type backplane is used) 16k steps (32k steps with expansion memory) A (optional memory) 0.35s/step (basic instructions) 6000 words (Exc. file register. See the end of this table.) 4048 points A (ET-LAN unit) A (Slave, FNS unit; master FMU) A (Slave, FNS unit; master FMU) A (Slave, FNS unit; master FMU) N/A N/A A (COM port, CCU, MCU) A (COM port, SDU, MCU) A (MW link unit) A (MCU) A (MW link unit) N/A A (Master: MW link unit) (Slave: RMS unit) A (FP2-C1SL, S-LINK unit) N/A RTEX, multifunction type, interpolation type 4 points/30kHz/100 resolution (Pulse I/O unit) 4 points/200kHz (FP2-HSCT, FP2-PXYT) 8 ch (FP2-AD8VI, FP2-AD8X) 4 ch (FP2-DA4) 8 ch thermocouple/RTD (FP2-AD8X, FP2-RTD) A (optional memory EM1, EM2, EM3) File register (0 to 14,333 words) C1SL

Scan time: 1ms/20k steps Advanced version of FP2 capable of ultrahigh speed processing
Ultra-high speed model that shares units with FP2, ideal for high-speed control of electronic device manufacturing equipment High program capacity of 120k steps 60k step type also available Compatible with Small PC Cards, which serve as a program backup or extended memory for processing a large volume of data 8192 I/O points max. (remote I/O system)

CPU (control unit) model Maximum controllable I/O points Connectable expansion units Program capacity Comment memory Operation speed Data register Internal relay Ethernet PROFIBUS DP DeviceNet CANopen Modbus-RTU Network compatibility CC-Link Computer link (MEWTOCOL) General-purpose serial (nonprocedural) PLC link W W0 W2 VE Remote I/O (MEWNET-F) S-LINK Built-in pulse output Motor control Positioning unit PWM output High-speed counter
Analog measurement

C14 336 points

C30 352 points

C60 382 points

C2

C2P

C3P

2048 points (8192 points with remote I/O system) 32 units (when the H type backplane is used) 32k steps A (built-in memory) 0.03s/step (basic instructions) 10,240 words (Exc. file register. See the end of this table.) 14,192 points A (ET-LAN unit) A (Slave, FNS unit; master FMU) A (Slave, FNS unit; master FMU) A (Slave, FNS unit; master FMU) N/A N/A A (COM port, CCU, MCU) A (COM port, SDU, MCU) A (MW link unit) A (MCU) N/A A (VE link unit) A (Master: MW link unit) (Slave: RMS unit) A (S-LINK unit) N/A RTEX, multifunction type, interpolation type 4 points/30kHz/100 resolution (Pulse I/O unit) 4 points/200kHz (FP2-HSCT, FP2-PXYT) 8 ch (FP2-AD8VI, FP2-AD8X) 4 ch (FP2-DA4) 8 ch thermocouple/RTD (FP2-AD8X, FP2-RTD) A (built-in type) File register (32,765 words, 3 banks)

8 units + add-on cassettes (up to 3) 16k steps 32k steps A (built-in memory) 0.32s/step (basic instructions) 12,285 words 32,765 words

4096 points (256 words) A (Ethernet communication cassette) N/A N/A N/A A (RS485 communication cassette) A (Slave, FP0 CC-Link unit) A (Tool port, communication cassette) A (Tool port, communication cassette) N/A A (RS485 communication cassette) N/A N/A A (64-point slave stations, FP0 I/O link unit) N/A 2 axes/100kHz + 2 axes/20kHz (transistor output type) 1 axis/100kHz (pulse I/O add-on cassette) 4 points/12kHz/1000 resolution (transistor output type) 8 ch/50kHz 2 ch/cassette 2 ch/cassette 2-ch input and 1-ch output mixed cassette

Voltage/current input Voltage/current output Temperature input

2 ch thermocouple input cassette A (MRTC cassette) With a USB port (C30/C60)

Calendar timer (clock function) Others


N/A: Not available A: Available

09/2008

The Panasonic PLC range


Compatible network diagram
Ethernet
(Information) Ethernet

FP2SH

FP0

FP

FP-X

Other companys PLC

Open field networks


(Control)

PROFIBUS-DP DeviceNet

CANopen

PROFIBUS-DP DeviceNet

CANopen CC-Link

Connectable as masters

Connectable as slaves

FP2

FMU

FP

FMU

FP2 FP2SH

FP

FP2 FP2SH

FPX

FP0

Matsushita protocol PLC link


(Control)

MEWNET-W0

MEWNET-W2

MEWNET-W

FP-X

FP

FP2 FP2SH

FP2 FP2SH

FP2 FP2SH

FP2 FP2SH

FP2 FP2SH

Remote I/O
(Bit processing) MEWNET-F S-LINK

FP2 FP2SH

I/O terminal board

FP0 I/O link unit

FP I/O link unit

I/O terminal unit

Sensors and terminals for S-LINK

C-NET (RS485)
1:N serial communications

C-NET

FP-X

FP

FP0

FP-e

KT Temperature Controller

KW Eco-Power Meter

RS232C
1:1 serial communications RS232C

GT Display

PV Imagechecker

09/2008

Compatible network table


network applications and features
Connection to PCs or workstations by a standard LAN, Ethernet For data collection and operation control Capable of 10 Mbps high-speed or 1200m long distance communications One of the worlds most popular open fieldbuses 12Mbps high-speed communications Transmission up to 12km is possible by using a repeater Developed based on CAN, as popular as PROFIBUS. Master-slave configuration as well as peer-topeer configuration is possible. As with DeviceNet, CAN-based industrial network Widespread, particularly in Europe 128-station multi-master-slave communications PLC link capable of mixed connection of FP2SH, FP2, FP-X, and FPS (Sigma) Distributed control allows target PLCs to be selected. 32 stations, 1200m max. 4k bit link relay, 4k word link data 16 stations, 800m max. 1k bit link relay, 128 word link data Wire-saving I/O control through centralized program control Up to 32 slave stations and 2048 points can be controlled. 4-wire T-branch wiresaving I/O control system Easy to connect sensors and I/O terminals with a single motion Capable of 1:N computer links (MEWTOCOL communications) for small-size PLCs and other RS485 devices 1:1 computer links (MEWTOCOL communications) by RS232C For communications with GT Displays, PV Imagechecker, etc. Capable of monitoring PLCs in remote locations or updating programs via the public telephone line
A: Available

Transmission cable
UTP cable or transceiver cable CC-Link dedicated cable (twisted pair cable) Type A cable for PROFIBUS-DP (twisted pair cable)

Transmission speed
10Mbps/ 100Mbps

Transmission distance
Max segment: 500m Max. distance between nodes: 2500m

Supported function
PLC links MasterSlave Remote I/O systems Computer link FP2SH

Compatible PLCs
FP2 FP-X FPS (Sigma) FP0 FP-e

Ethernet

N/A

N/A

CC-Link

10Mbps (100m) 5Mbps (160m) 2.5Mbps (400m) 625kbps (900m) 156kbps (1200m)

N/A

N/A

N/A

N/A

N/A

PROFIBUS-DP Open networks

12Mbps

12km when using a repeater)

N/A

N/A

A (Master/slave)

N/A

A A (Master/ (Slave) slave)

N/A

DeviceNet

Dedicated 4-wire shielded cable (Thick/Thin)

500kbps (100 m) 250bps (250 m) 125kbps (500 m)

N/A

N/A

A (Master/slave)

N/A

A (Master/ slave)

N/A

N/A

CANopen

Twisted-pair shielded cable Also compatible with fourwire power bus cables.

1Mbps (25m) to 10kbps (500m)

N/A

N/A

A (Master/slave)

N/A

A (Master/ slave)

N/A

N/A

MEWNET-W0 PLC links

Twisted-pair cable

115 kbps

1200 m

N/A

N/A

N/A

N/A

N/A

MEWNET-W2 MEWNET-W

Twisted-pair cable Twisted-pair cable

500kbps (800m) 250kbps (1200m) 500kbps 800m

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Remote I/O systems

MEWNET-F

VCTF or twisted-pair cable

500kbps

VCTF 400m twisted-pair cable 700m

N/A

N/A

N/A

N/A

S-LINK

Dedicated 4-wire flat cable or cabtyre cable

28.5kbps

200m (400m when using a booster)

N/A

N/A

N/A

N/A

N/A

Serial communications

C-NET (RS485)

VCTF or twisted-pair cable

19,200bp/ 9600bps

1200m

N/A

N/A

CCU (RS232C)

RS232C

19200bp/ 9600bps

15m

N/A

N/A

Modem (phone line)

RS232C and phone line

2400kbps

To the modem: 3 to 15m

N/A

N/A

N/A: Not available

09/2008

CO M PACT BO DY 09/2008

fP0 series
Incredibly small, as single or even as multiple combined units
feaTureS
 Measures only 25 x 90 x 60mm (WxHxD)
Industrys smallest class ideal for installation in equipment and size reduction of control panels * The 32-point type control unit is 30mm wide. The stacking connector allows a base-less expansion. Even when three expansion units are added to the control unit, the total width is as small as 105mm.

 A wide variety of analog converter units ideal for measurement or temperature control
The lineup includes an 8-ch A/D converter unit, 4-ch D/A converter unit, mixed 2-ch A/D and 1-ch D/A converter unit, 4-ch and 8-ch type thermocouple units. Control of up to 24 ch of analog data is possible.

 Expandable to 128 I/O points by adding up to 3 units

Performance specifications
Model Programming method/ Control method Number of I/O points No expansion (control unit only) W/expansion 1
*Same type of control and expansion units Max. 58 points Max. 62 points Max. 112 points Max. 128 points Expansion section: Max. 96 points Max. 106 points Max. 110 points Max. 112 points Max. 128 points Max. 128 points Max. 128 points 10 points [Input: 6, relay output: 4] 14 points [Input: 8, relay output: 6] C10 series (Relay output type only) C14 series C16 series C32 series (Relay output type only) (Transistor output type only) (Transistor output type only) Relay symbol/Cyclic operation 16 points [Input: 8, PNP output: 8] 32 points [Input: 16, PNP output: 16] S-LINK section: max. 128 points [Input: 64, PNP output: 64] 32 points [Input: 16, NPN output: 16] S-LINK type T32 series (Transistor output type only)

W/expansion 2
*Mix type of relay and transistor units

Program memory Program capacity Processing speed


Number of instructions 2720 steps

EEPROM (no back-up battery required) 5000 steps 0.9s/step (basic instruction) 83 115 0.9s/step (for basic instruction) 1008 points 144 points 1660 words 2 words 32 64 Unlimited 128 16 1 phase / 4 points (10kHz) or 2 phases / 2 points (2kHz in total)*) 2 points (output frequency up to 10kHz) 0.15Hz to 38Hz (ver. 2 or later: 1kHz max.) 6 inputs (catches pulses of 50s) 7 programs (external 6 inputs + periodical interrupt) 0.5ms to 30s Available One RS232C port is mounted on each of the models FP0- C10CR, C14CR, C16CT, C32CT, T32CT and SL1 type (3P terminal block) Transmission speed (Baud rate): 300 to 19,200bit/s, Transmission distance: 3m Communication method: half duplex Stored program and system register in EEPROM Backup is provided by secondary battery. The holding range for the timers, counters, internal relays, and data registers are specified with the programming tool. 1 program (internal 1 point) Available (same as 32 points series) 704 100 255 6144 words 16,384 words 10,000 steps

Basic High-speed Internal relay (R) Timer/Counter (T/C) Data register (DT)

Operation speed (central value/step)


Memory area Relay

Operation memory points Special functions

Index register (IX,IY) Master control relay points (MCR) Labels (JMP + LOOP) Differential points Number of step ladder Number of subroutines High speed counter Pulse output PWM output Pulse catch input/ Interrupt input Interrupt program Periodical interrupt Constant scan RS232C port Program and system register
Stored fixed area in EEPROM Counter: 4 points Internal relay: 32 points Data register: 8 words

Memory back up

Maintenance

Operation memory

Stored fixed area in EEPROM Counter: 16 points Internal relay: 128 points Data register: 32 words Watchdog timer, program syntax check Not available Run time editing, password setting

Self-diagnostic function Clock/Calender function Other functions


* For limitations during operation, please refer to the manual.

Available

09/2008

fP0 series
A wide variety of both single and combined units
Control units
relay output type Transistor output type

10 points Input 6 points Output 4 points

10 points Input 6 points Output 4 points

14 points Input 8 points Output 6 points

14 points Input 8 points Output 6 points

16 points Input 8 points Output 8 points

16 points Input 8 points Output 8 points

32 points Input Output 16 points 16 points FP0-C32PA (PNP) FP0-C32TA (NPN)

32 points Input Output 16 points 16 points FP0-C32CPA (PNP) FP0-C32CTA (NPN) with 2nd RS232C

FP0-C10RSA

FP0-C10CRSA with 2nd RS232C

FP0-C14RSA

FP0-C14CRSA with 2nd RS232C

FP0-C16PA (PNP) FP0-C16TA (NPN)

FP0-C16CPA (PNP) FP0-C16CTA (NPN) with 2nd RS232C

Control units 10k


fP0-T32
This advanced fP0 CPu offers additional features: 10,000 steps program memory Battery backed RAM Real-time clock 16,383 words data register
32 points Input 16 points Output 16 points

fP memory Loader
afP8670
ead or write programs R (up to 60k steps) from or to a PLC ersonal computer is not P required pplicable with FP0, FP-e, A FP (Sigma), FP-X, FP2 and FP2SH

S-LinK maSTer CPu


fP0-SL1
ontrol of 64 input and 64 output C points is possible with one unit imple connection of S-LINK I/O S devices ensors can be easily connected S with plug-in connections

FP0T32CPA (PNP) with 2nd RS232C FP0T32CTA (NPN) with 2nd RS232C

Control u nit

from 10 i/os

up to 128 i/os

Expansio

n unit

25mm

The photo shows an example of expanding by adding three expansion units to an I/O 32-point control unit.

90mm

input/output terminal The photo shows an I/O 14-point control unit. This size is uniform for all except the I/O 32-point control unit. Com port: 2nd rS232C interface (optional for all CPU units for serial communication)

TooLport Hooks up by using the programming software Panasonic Control FPWIN Pro or FPWIN GR and a single cable.

10

09/2008

fP0 series
A maximum of 3 expansion units can be added to the CPU unit
digital i/o units
relay output type input only type Transistor output type

8 points Input Output 4 points 4 points FP0-E8RSA option Output 8 points FP0-E8YRSA

16 points Input Output 8 points 8 points FP0-E16RSA

32 points Input Output 16 points 16 points FP0-E32RS

8 points Input 8 points FP0-E8XA

16 points Input 16 points FP0-E16XA

8 points Output 8 points FP0-E8YPA (PNP) FP0-E8YTA (NPN)

16 points Input Output 8 points 8 points FP0-E16PA (PNP) FP0-E16TA (NPN)

16 points Output 16 points FP0-E16YPA (PNP) FP0-E16YTA (NPN)

32 points Input Output 16 points 16 points FP0-E32PA (PNP) FP0-E32TA (NPN)

analog i/o units

Temperature control units

3 points Input 2 points Output 1 point

4 points Output 4 points FP0-A04I

4 points Output 4 points FP0-A04V

8 points Input 8 points FP0-A80A

4 points Input 4 points FP0-TC4

8 points Input 8 points FP0-TC8

6 points Input 6 points FP0-RTD6

FP0-A21A

nput (12 bit): I 10V, 0 5V, 0 20mA utput (12 bit): O 10V, 0 20mA

4 20mA

10V

10V, 100mV 0 5V, 0 20mA

, J, T, R type thermocouples K can be used esolution: 0.1C R ccuracy: .8C (R type: 3C) A 0 emperature range: T -100 to 1500C

t100, Pt1000, P Ni1000 emperature range: T -200 to 500C

networking units
ethernet fPweB2 (Web-Server Unit) ProfiBuS fP0-dPS2 (DP Slave) mewneT-f fP0-ioL (MEWNET-F Slave)

easy expansion
The expansion unit can be attached easily without any cables to the control unit. Special expansion cables, backplanes, and so forth, are unnecessary as the expansion unit employs a stacking system that uses expansion connectors and lock levers on the surface of the unit itself.
09/2008
Expansion unit Expansion unit Expansion unit

Control unit

(Maximum possible expansion is with a total of three units)

11

fP0-PSa2 / fP-PS24-050e
24VDC power supplies
features
E incredibly small size: E multiple voltage input: E global approvals

FP0 power supply: FP power supply: FP0 power supply: FP power supply:
30.4mm

90 x 60 x 30.4mm 115 x 75 x 42mm 0.7A (24VDC) 2.1A (24VDC) Performance specifications


Part number: Primary side: Rated operating voltage Operating voltage range Rated operating frequency Operating frequency range Inrush current Current consumption Over voltage protection Secondary side: Rated output voltage Output voltage range Nominal output current Output current range

85 to 265VAC
E optimal protection:

UL/cUL, EN, CE-marking


E din-rail mounting

E maximum output current:

vervoltage, overcurrent, o overheating, etc.

FP0 power supply ( also sidemounting)

fP0-PSa2 115/230VAC 85 to 265VAC 50/60Hz 40 to 70Hz < 50A at 55C 145mA (at 230VAC and 0.7A output current) PROTECTED 24VDC 23.5V to 24.5VDC 0.7A 0 to 0.7A < 60mVpp Electronic, automatic restart mode Yes Yes (switch off at approx. 0.8A and more) Min. 20ms at 230VAC

fP-PS24-050e

90mm

< 50A at 25C/< 70A at 55C 400mA (at 230VAC and 2.1A output current)

2.1A 0 to 2.1A < 240mVpp Continuous Yes (switch off at approx. 3.5A and more) Min. 110ms at 230VAC Yes

fP0 Power Supply fP0-PSa2


42mm

Output ripple Short circuit protected Over voltage protected Over load protected Holding time Power OK signal

general specifications
Ambient temperature Storage temperature Ambient humidity 115mm Storage humidity Vibration resistance Shock resistance Life time min. Mounting Size Input connection AC side Output connection DC side Status display Efficiency
NOTES: 1) Mounting distance between the FP0 power supply and the FP0 CPU is needed to permit heat radiation for the FP0-CPU 2) For side mounting, 2 additional blue clips are needed: order part-no. 677021-17101 (1pce.) for FP0-PSA2 3) Mounting distance between the power supply FP-PS24-050E and other devices is needed for cooling/ heat radiation.

0C to +55C -20C to +70C 5 to 95% non-condensing 5 to 95% non-condensing 10 to 55Hz, 1 cycle/min.: double amplitude of 0.75mm, 10 min. on 3 axes 10g min., 4 times on 3 axes 7 years at nom. load, 25C ambient temperature, 20,000h at 55C with full load/continuous operation DIN rail or FP0 flat attachment plate 90 x 60 x 30.4mm MC connector, 2 pin MC connector, 6 pin, 3 pin for + and 3 pin for - 80% DIN rail 115 x 75 x 42mm 2 pin 5 pin, 2 pin for + and 2 pin for -; 1 pin Power OK 85%

fP Power Supply fP-PS24-050 e

LED (green) at the front side for the secondary voltage indication

Standards
EMC LVD Others Protection EN 50082-2, EN50082-1, EN 50081-2, EN 50081-1 EN 60950, EN 50178 (overvoltage category 3) EN 55011/B, EN 55022/B, EN 61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-11 EN 60950, EN 50178 (overvoltage category 2)

UL recognized according to UL 508, UL 1950, cUL recognized according to CAN/CSA-C22.2 No. 950.95 IP30 IP20 outside/IP67 inside

12

09/2008

fP (Sigma)
The next generation compact PLC
feaTureS
 Abundant program capacity 32k steps
The 32k step program capacity can accommodate an increase in the number of programs accompanying functionality enhancements, expansions, or changes of equipment. All of 100,000 I/O comments, 5000 lines of line-space comments, and 5000 lines of remark comments are saved in FPS (Sigma) together with programs. Equipped with a RISC processor, achieving high-speed processing with a scan time of less than 2ms for 5000 steps.

 High-speed positioning unit  Simple temperature control

 Equipped with an independent comment memory  Equipped with a high-speed RISC processor

The 4Mbps maximum frequency and startup speed of 0.005ms allow use for linear servo control. A temperature control program can be written in only one line by using the PID F356 (EZPID) instruction, facilitating temperature control by a PLC, which had previously been considered difficult.

Performance specifications
Part number Number of I/O points 32k type 12k type (discontinued in 2008) FPG-C32T2H-A FPG-C32T2HTM
32 points (DC input: 16, PNP output: 16) Max. 128 points (up to 3 units) When using transistor output type expansion units Max. 288 points (up to 4 units) When using transistor output type expansion units Max. 384 points When using transistor output type expansion units

FPG-C24R2H-A FPG-C24R2HTM
24 points (DC input: 16, relay output: 8) Max. 120 points (up to 3 units) When using transistor output type expansion units Max. 280 points (up to 4 units) When using transistor output type expansion units Max. 376 points When using transistor output type expansion units Relay symbol/cyclic operation Built-in flash ROM (without backup battery) 32k steps (32k type), 12k steps (12k type) 93

FPG-C28P2H-A FPG-C28P2HTM
28 points (DC input: 16, PNP output: 12) Max. 124 points (up to 3 units) When using transistor output type expansion units Max. 284 points (up to 4 units) When using NPN output type expansion units Max. 380 points When using NPN output type expansion units

Control unit
With FP0 expansion units With FPS (Sigma) expansion units With FP0 and FPS (Sigma) expansion units

Programming method/ Control method Program memory Program capacity


Number of instructions

Basic High-speed Internal relay (R)


218

216 Basic instruction: 0.32s/step (32k type), 0.4 s/step (12k type) 4096 points (32k type): R0 to R255F, 1568 points (12k type): R0 to R97F
1)

218

Operation speed
Relay 1024 points
1) 2)

Operation memory points

Timer/Counter (T/C) Link relays (L) Data register (DT) Link data register (LD)

(for initial setting, timer: 1008 points (T0 to T1007), counter: 16 points (C1008 to C1023) Timer: Counts each unit up to 32767 times (units: 1ms, 10ms, 100ms, or 1s). Counter: Counts 1 to 32,767 2048 points (32k type), 1024 points (12k type) 32,765 words (DT0 to DT32764)
1) 1) 1)

Memory area

256 words (32k type), 128 words (12k type) 14 words (I0 to ID) 256 256 Unlimited 1000 stages 100 8 points (X0 to X7)

Index register (IX,IY) Master Control Relay points (MCR) Labels (JMP + LOOP) Differential points Number of step ladder Number of subroutines Pulse catch input Interrupt program Self-diagnostic function Clock/Calender function Potentiometer (Volume) input Battery life Comment storage Link function Other functions Linear/Circular interpolation for positioning

9 programs (8 external input points (X0 to X7), 1 periodical interrupt point '0.5ms to 30s') E. g. watchdog timer, program syntax check Available (year, month, day, hour, minute, second and day of week); however, this function can only be used when a battery has been installed 3). 2 points, resolution: 10 bits (K0 to K1000) 220 days or more (actual usage value: approx. 840 days (25C). Suggested replacement interval: 1 year. Value applies when no power at all is supplied. All kinds of comments, including I/O comments, remarks, and block comments, can be stored (without backup battery). Computer link (1:1, 1:N)
4)

General-purpose communication (1:1, 1:N)

4) 5)

PLC link

6)

Program edition during RUN, constant scan, forced on/off, password, floating-point operation, and PID processing Available Not available Available

Notes: 1) If no battery is used, only the fixed area is backed up (counters 16 points: C1008 to C1023, internal relays 128 points: R900 to R97F, data registers 55 words: DT32710 to DT32764). When the optional battery is used, data can be backed up. Areas to be held and not held can be specified using the system registers. 2) The number of points can be increased by using an auxiliary timer. 3) Precision of calendar timer: - At 0C 32F, less than 119 seconds error per month. - At 25C, less than 51 seconds error per month. - At 55C, less than 148 seconds error per month.

4) An optional communication cassette (RS232C type) is required in order to use 1:1 communication. (Re-send processing is recommended.) 5) An optional communication cassette (RS485 type) is required in order to use 1:N communication. (Re-send processing is recommended.) 6) An optional communication cassette (RS485 type) is required. The number of points actually available for use is determined by the hardware configuration.

09/2008

13

fP (Sigma) CPus
Outstanding performance in a compact design
fPS (Sigma) Transistor output type fPS (Sigma) relay output type fPS (Sigma) i/o expansion units

28 points Input 16 points Output PNP 12 points

32 points Input 16 points Output NPN 16 points

24 points Input 16 points Output relay 8 points

64 points Input 32 points Output PNP 32 points

MIL connector type FPG-C28P2H-A

MIL connector type FPG-C32T2H-A

Screw terminal type FPG-C24R2H-A

MIL connector type FPG-XY64D2P-A

fPS (Sigma) Transistor output type with thermistor input

fPS (Sigma) relay output type with thermistor input

28 points Input 16 points Output PNP 12 points

32 points Input 16 points Output NPN 16 points

32 points Input 16 points Output relay 16 points

64 points Input 32 points Output NPN 32 points

2 thermistor inputs FPG-C28P2HTM

2 thermistor inputs FPG-C32T2HTM

2 thermistor inputs FPG-C24R2HTM

MIL connector type FPG-XY64D2T-A

HigH eXPanSion CaPaBiLiTy


FPS (Sigma) can use the expansion units of the FP0 on the right-hand side. New FPS (Sigma) units can be added to the left hand side.
Max. 4 expansion units each 64 I/Os = 256 I/Os

up to 384 i/o!
Parallel expansion BUS

CPU max. 32 I/Os Serial expansion BUS

Max. 3 expansion units each 32 I/Os = 96 I/Os

14

09/2008

fP (Sigma) expansion units


Wide variety of expansion units
fPS (Sigma) fieldbus master expansion units fPS (Sigma) fieldbus slave expansion units

fPg-dPv1-m

fPg-Can-m

fPg-dev-m

fPg-SL

fPg-CCSL

fPg-fnS Flexible network slave unit for PROFIBUS, DeviceNet, CANopen

PROFIBUS Master unit

CANopen Master unit

DeviceNet Master unit

S-LINK Master unit

CC-Link Slave unit

fPS (Sigma) positioning expansion units

fPS (Sigma) rTeX positioning expansion units

1-axis Transistor output FPG-PP11 Line driver output FPG-PP12

2-axis Transistor output FPG-PP21 Line driver output FPG-PP22

2-axis fPg-Pn2an

4-axis fPg-Pn4an

8-axis fPg-Pn8an

Simplifies multi-axis high precision positioning with Panasonic Minas A4N network servo drives.

fPS (Sigma) communication cassettes

Plug-in communication units for fPS (Sigma) fnS expansion units

fPS (Sigma) memory expansion unit

FPG-COM1-A: FPG-COM2-A: FPG-COM3-A: FPG-COM4-A:

1 channel RS232C 2 channels RS232C 1 channel RS485 1 channel RS232C & 1 channel RS485

AFPN-AB6200: PROFIBUS plug-in unit AFPN-AB6201: DeviceNet plug-in unit AFPN-AB6218: CANopen plug-in unit

fPg-em1 Memory: 256k words FPG-EM1

09/2008

15

XXXXXXXX
xxxxxxxxxxx xxxxx

16

09/2008

fP-X series
An advanced compact model
feaTureS
 Abundant program capacity 32k steps
The 32k step program capacity can accommodate an increase in the number of programs accompanying functionality enhancements, expansions, or changes of equipment. All of 100,000 I/O comments, 5000 lines of line-space comments and 5000 lines of remark comments are saved in FP-X together with programs. Equipped with a RISC processor, achieving high-speed processing with a scan time of less than 2ms for 5000 steps.

 Equipped with an independent comment memory  Equipped with a high-speed RISC processor

 Add-on cassettes can expand the functionality, maintaining the space-saving size
Up to three add-on cassettes can be attached to the control unit. Functionality can be enhanced without increasing the required footprint. The 16 types of add-on cassettes, including the communication and analog types, cover a wide variety of applications.

 Multi-axis control by the built-in pulse output

The transistor output type controller has a built-in pulse output that allows multi-axis control of the servo and stepping motors. C14: 3 axes, C30/C60: 4 axes.

HigH SeCuriTy uSB-PorT


* Not provided with a C14

Program protection with an 8-digit password and a function prohibiting uploads easy direct connection with a PC via a commercial uSB cable (aB type)

PLC type
Number of inputs Number of outputs Output capacity Max. number of digital I/O Max. number of analog I/O Processing speed Memory Memory type Program capacity Data register Special functions

afPX-C14
8 6 relays or transistors 366

afPX-C30
16 14 relays or transistors Relay outputs: 2A, transistor outputs: 0.5A 352 26 0.32s/step (basic instruction) Built-in Flash ROM C14: 16k steps, C30/C60: 32k steps C14: 12,285 words, C30/C60: 32,765 words Input of main unit: Transistor output types: Single-phase 8ch (50kHz x 4ch + 10kHz x 4ch), Two-phase 4ch (35kHz x 1ch, 25kHz x 1ch, 5kHz x 2ch) Relay output types: Single-phase 8ch (10kHz x 8ch), Two-phase 4ch (5kHz x 4ch) Input of pulse I/O cassette AFPX-PLS (for relay output types): Single-phase: 2 channels 80kHz or 4 channels 50kHz Two-phase: 1 channel: 30kHz or 2channels: 25 kHz

afPX-C60
32 28 relays or transistors 382

High-speed counter

Pulse output Serial interfaces Real-time clock Other functions Operating voltage range

Built-in transitor outputs: 100kHz x 2ch + 20kHz x 2ch Pulse I/O cassette AFPX-PLS (for relay output types only): One unit (one axis) 100kHz, or two units (two axes) 80kHz Up to 3 serial interfaces, C30/C60 also USB port Available when AFPX-MRTC installed Password (4 digits, 8 digits), upload protection, comment storage (328kByte) 85 to 264VAC (AC power), 20.4 to 28.8VDC (DC power)

09/2008

17

fP-X series
High adaptability
add THe CaSSeTTeS you need To meeT your individuaL needS
The add-on cassettes can easily be mounted onto the control unit, up to 2 cassettes on the C14 or 3 cassettes on the C30/C60. By using one communication cassette, which can be stacked on top of another expansion cassette, even the FP-Xs communication can be expanded.

BuiLT-in 4-aXiS PuLSe ouTPuT: 2-aXiS Linear inTerPoLaTion SimuLTaneouSLy in Two SeTS
The transistor output type C14 comes with 3-axis while C30/60 comes with 4-axis pulse output inside the control unit. The multi-axis control, which previously required a higher-level PLC or additional positioning unit, or two or more PLC units, can now be achieved with only one FP-X transistor output type unit in a small space at a low cost. FP-X transistor output type is capable of simultaneously controlling 2-axis linear interpolation, for the first time in the industry with a compact pulse-output PLC.

Easily removable (two screws to secure the unit)

THe maSTer memory CaSSeTTe maKeS TranSferring a Program eaSy, and a reaL-Time CLoCK iS aLSo inCLuded
The built-in 1MB flash-ROM can store a 32k step program as well as the comments of FPWIN Pro source file. The master memory cassette allows you to conveniently update a program on an FP-X in the field. Because the master memory cassette can store password information, you can easily enjoy all the security features the FP-X offers even when transferring program in the field. The built-in real-time clock enables repeated periodical control and data logging.
To the field operation Master memory

Program transfer Program transfer

Password used -> Password locked


FPWIN GR/Pro

Upload prohibited set -> Upload prohibited


FP-X FP-X

Upload prohibited not set -> Upload permitted

eXPenSive uSB ConverSion adaPTer/CaBLe unneCeSSary


Now you can connect your PC directly to the FP-X C30s or C60s USB port.
PC

Before

PC

RS232C/422 conversion adapter

FP1

afPX-C30/C60 AFPX-C30R/C60R

USB conversion cable

Now with USB direct connection

The conventionalRS232C port rS232C The conventional can also also be used port can be used

18

09/2008

fP-X series
Product lineup
THe HigHLy eXPandaBLe LineuP SaTiSfieS a wide range of demandS
Control unit
dC power supply afPX-C14rd
8-point input of 24VDC Program capacity: 16k steps 6-point output of 2A relay 2-point potentiometer

relay ouput aC power supply afPX-C14r


8-point input of 24VDC 6-point output of 2A relay

Transistor ouput dC power supply afPX-C14Td (nPn) afPX-C14Pd (PnP)


8-point input of 24VDC 0.5A/5 to 24VDC 6-point output of transistor

aC power supply afPX-C14T (nPn) afPX-C14P (PnP)


8-point input of 24VDC 0.5A/5 to 24VDC 6-point output of transistor

dC power supply afPX-C30rd


Program capacity: 32k steps 2-point potentiometer, equipped with a USB communication port 16-point input of 24VDC 14-point output of 2A relay

aC power supply afPX-C30r


16-point input of 24VDC 14-point output of 2A relay

dC power supply afPX-C30Td (nPn) afPX-C30Pd (PnP)


16-point input of 24VDC 0.5A/5 to 24VDC 14-point output of transistor

aC power supply afPX-C30T (nPn) afPX-C30P (PnP)


16-point input of 24VDC 0.5A/5 to 24VDC 14-point output of transistor

dC power supply afPX-C60rd


Program capacity: 32k steps 4-point potentiometer, equipped with a USB communication port 32-point input of 24VDC 28-point output of 2A relay

aC power supply afPX-C60r


32-point input of 24VDC 28-point output of 2A relay

dC power supply afPX-C60Td (nPn) afPX-C60Pd (PnP)


32-point input of 24VDC 0.5A/5 to 24VDC 28-point output of transistor

aC power supply afPX-C60T (nPn) afPX-C60P (PnP)


32-point input of 24VDC 0.5A/5 to 24VDC 28-point output of transistor

expansion unit

relay ouput

Transistor ouput afPX-e16T (nPn) afPX-e16P (PnP)


8-point input of 24VDC 0.5A/5 to 24VDC 8-point output of transistor

afPX-e16r
Remarks: 2 or more E16s cannot be connected serially because they cannot supply the power to other units. 8-point input of 24VDC 8-point output of 2A relay

dC power supply afPX-e30rd


Remarks: Addition of up to 8 units is possible including E16 and EFP0. 16-point input of 24VDC 14-point output of 2A relay

aC power supply afPX-e30r


16-point input of 24VDC 14-point output of 2A relay

dC power supply afPX-e30Td (nPn) afPX-e30Pd (PnP)


16-point input of 24VDC 0.5A/5 to 24VDC 14-point output of transistor

aC power supply afPX-e30T (nPn) afPX-e30P (PnP)


16-point input of 24VDC 0.5A/5 to 24VDC 14-point output of transistor

add-on cassette
application cassette afPX-in4T3 afPX-in8 afPX-Tr8 afPX-Tr6P
Input/output cassette (4-point input of 24VDC, NPN 0.3A/3-point output of 24VDC) Input cassette (8-point input of 24VDC) Output cassette (NPN 0.3A/8-point output of 24VDC) Output cassette (PNP 0.5A/6-point output of 24VDC) Pulse I/O cassette (High-speed counter input: single phase 80kHz 2ch, 2-phase 30kHz 1ch) (Pulse output: 1 axis 100kHz < CW/CCW, pulse + sign >) *Cannot be built into a transistor output type. Analog input cassette (2 points, 0 to 10 V/0 to 20mA 12-bit non-insulated) Analog I/O cassette Input: 2ch (0 to 5V/0 to 10V or 0 to 20mA 12-bit insulated) Output: 1ch (0 to 10V or 0 to 20mA 12-bit insulated) Analog output cassette 2ch (0 to 10V or 0 to 20mA 12-bit insulated 2ch) Thermocouple input cassette, (K/J type, resolution: 0.2C, insulated 2ch) Master memory cassette with a real-time clock* (32k steps program memory + real-time clock in year/month/day/hour/minute) *Real-time clock requires an optional battery. (Real-time clock Calendar timer)

Communication cassette afPX-Com1 afPX-Com2 afPX-Com3 afPX-Com4 afPX-Com5


Communication cassette (RS232C 1ch) Communication cassette (RS232C 2ch) Communication cassette (RS485/422 selectable 1ch insulated) Communication cassette (RS485 1ch insulated + RS232C 1ch) Communication cassette (Ethernet 1ch + RS232C 1ch)

afPX-PLS

afPX-ad2 afPX-a21 afPX-da2 afPX-TC2

afPX-Com6

Communication cassette (RS485 2ch insulated)

afPX-mrTC

expansion fP0 adapter


afPX-efP0
Up to 3 FP0 expansion units can be connected.

09/2008

19

fP-e series
Timer, counter, hour meter, temperature controller and PLC in one unit
features
 5-character, 2-line, 3-color display  Front operation switch  Equivalent to FP0-C14 intelligence of small PLCs  Easy programming using wizard  Smooth debug  Panel mounted type

display modes and functions


n mode (Normal mode)
FP-e
N S

S mode (Switch mode)


FP-e

r mode (Register mode)


FP-e
R
PROG.

i mode (I/O monitor mode)


FP-e
I
PROG.

PV

PROG.

PROG.

Displays any characters and numerical values, and numerical data can be changed.

Can also display characters and numerical values. Operation switches can be used for input.

Operation memory in the controller can be monitored and its data can be changed.

I/O status (X, Y) in the controller can be displayed.

Specifications
Performance specifications
Model Number of I/O points Control unit
Front switch input AFPE224300 Basic type (RS232C) AFPE224302 Basic type (RS485) AFPE224305 Calendar timer type (RS232C) AFPE214325 Thermocouple input type (RS232C) AFPE214322 Thermocouple input type (RS485)

14 points [Input: 8, Output: 6 (Tr. NPN: 5/Ry: 1)] 8 points Built-in EEPROM 2720 steps 0.9s/step (for basic instruction)

12 points [Input: 6, Output: 6 (Tr. NPN: 5/Ry: 1)]

Program Built-in memory memory Program capacity Processing speed Clock/Calender function Battery life Pulse catch input/ Interrupt input COM port note Periodical interrupt High speed counter Special functions
* The combination of 1-phase x 2ch and 2-phase x 1ch is also possible for the highspeed counter.

Available (year, month, day, hour, minute, second and day of week). However, this can only be used when a battery has been installed. 220 days or more (actual usage value: approx. 870 days (25C) (Periodic replacement interval: 1 year) (Value applies when no power is supplied at all.) 6 points in total (X0 and X1: 50 s, X2 to X5: 100 s)

RS232C

RS485

RS232C 0.5ms to 30s

RS232C

RS485

Counter mode: Addition/subtraction (1-phase) - input points: 4ch (max.)

Pulse output

Output points Outtput frequency Output points Output frequency


40Hz to 10kHz (Y0/Y1: 1-point)

2 independent points (Y0 and Y1) (No interpolation function) 40Hz to 5kHz (Y0/Y1: 2-points) 2 points (Y0 and Y1) Frequency: 0.15Hz to 1kHz Duty: 0.1% to 99.9% 40Hz to 5kHz (1-point) 40Hz to 2.5kHz (2-points)

20

PWM output

09/2008

fP-e series
Optimized for a wide range of applications
equipped with rS485 and rS232C interfaces
up to 99 computer link stations possible with rS485 (rS485 type) Up to 32 computer link stations are possible using a C-NET adaptor and up to 99 are possible using a commercially available adaptor. You can easily monitor operation status or perform control.
ComPuTer LinK
Personal Computer Personal Computer RS232C RS232C FP-e FP-e FP-e FP-e FP-eFP-e FP-e FP-e FP-e FP-e RS232C RS232C RS232C Commercially available adapter Commercially FP-e FP-e FP-e FP-e FP-e FP-e FP-e FP-e RS232C RS232C Computer Personal Personal Computer Personal Computer Personal Computer Personal Computer Personal Computer FP-e FP-e RS232C FP-e FP-e

with rS232C, communication possible with up to two ports (rS232C type)

Personal Computer Personal Computer Personal Computer Personal Computer Image Processing Device, etc. Image Processing Device, etc. Image Processing Image Processing FP-e Device, etc. FP-e Device, etc. RS232C RS232C RS232C RS232C
+ -

Image Processing Image Processing Device, etc. Device, etc.

RS232C RS232C
+ + + -

TooL PorT
RS485 RS485 RS232C RS232C

Com PorT
RS232C RS232C
+ + -

RS485 Commercially Commercially available adapter available available adapter RS485 adapter

Commercially Commercially available adapter available adapter

Can even handle temperature control


RS485 RS485

Two-point K-type thermocouple (-30 to 300C) connection possible (equipped with thermocouple input) Can be used in place of a temperature controller or used to control them. FP-e
FP-e FP-e FP-e

Pid instruction function High-performance temperature control can be achieved with PID instruction.

Y0

Y0PID instruction

As FP-e FP-e a temperature controller Y0 Y0


Temperature Temperature FP-e controller, etc. controller, etc. Temperature Temperature Temperature Temperature Temperature Temperature FP-e controller, etc. FP-e controller, controller, etc. controller, etc. etc. FP-e controller, etc. controller, etc.
PV OUT1 PV OUT1 OUT2 OUT2 SV PV A1 OUT1 EVT SV PV A1 OUT1 EVT PV PV OUT1 OUT1 PV PV OUT1 OUT1

PID instruction

Y0 Y0

PID instruction PID instruction Heater Heater Heater Heater

PID instruction PID instruction Thermocouple input

A0

A0

Thermocouple input

Thermocouple input Thermocouple input Heater A0 Heater A0

Temperature Temperature Temperature Temperature As a controller, FP-e FP-e controller etc. KT4controller, etc. KT4etc.Up to 32 controller, etc. controller, KT4 KT4 for temperature controllers controllersto KT4 KT4 Up 32 RS485
SV1 SV2 TX/RX AT OUT2 SV1 SV2 TX/RX AT OUT2 SV

MODE

OUT

SV

OUT2

OUT2

OUT2 SV SV A1

OUT2

A1

OFF

MODE

OUT

A1

SV

SV

OFF

A1

A1

A1

EVT

EVT

SV1

SV2

TX/RX

AT

SV1

SV2

TX/RX

AT

SV1

SV1 SV2

SV2 TX/RX

TX/RX AT

EVT AT

EVT

SV1

SV1 SV2

SV2 TX/RX

TX/RX AT

EVT AT

EVT

MODE

OUT

OFF

MODE

OUT

OFF

MODE

OUT MODE

OUT

OFF

OFF

MODE

OUT MODE OFF

OUT OFF

PV

PV

OUT1

PV

OUT1

PV

OUT1

KT4 KT4

OUT1

controllers RS485 * Compatible withRS485 MODBUS, it can be usedRS485 as a slave.


SV OUT2 SV OUT2 SV A1 SV A1 A1 A1 EVT EVT SV1 SV2 TX/RX AT EVT SV1 SV2 TX/RX AT EVT SV1 SV2 TX/RX AT SV1 SV2 TX/RX AT

OUT2

OUT2

Up A0 Up to to 32 32 controllers controllers

A0

Thermocouple input input Thermocouple

* Compatible with MODBUS, it canitbe used used slave. * Compatible with MODBUS, can be as a as a slave.

equipped with high-speed counter for support of 2-axis independent positioning


High-speed counter function In single phase, the 4-channel total is 10kHz, and in 2-phase the Cutter 2-channel total is 2kHzFeederspeed, making the FP-e suitable for total roller Cutter Cutter Feeder roller Cutter Feeder roller inverter control, etc. (One half for the type Feederthermocouple with roller input.) Lead wire
Feeder rollerroller Cutter and tape wire Cutter Feeder Lead and tape Inverter Motor Inverter Inverter Inverter Motor Motor Lead wire START/STOP Motor Lead wire Stepping motor Stepping motor Encoder Cutter blade signalSTART/STOP and tape tape andSTART/STOP Servo motor Servo motor START/STOP control signal Encoder Cutter blade Encoder signal Encoder Inverter signal signal Motor Motor Input encoder Inverter control signal outputInput the into encoder Input encoder Input encoder START/STOP START/STOP high-speed into the output output into output into the Encoder Cutter blade the Encoder Cutter blade signal signal counter high-speed high-speed high-speed control signal control signal InputInput encoder encoder counter counter counter output into the the output into high-speed high-speed counter counter
Lead wire Lead wire and tape and tape

* Compatible withKT4 KT4 KT4 Compatible with a slave. MODBUS,*it can be used asMODBUS, can bebe used as slave. KT4 * Compatible with MODBUS, it it can used as a a slave. Up toUp to 32 32 controllers controllers RS485 RS485
MODE OFF MODE OUT MODE OFF OFF MODE OUT OFF

OUT

OUT

Pulse output function The unit comes equipped with 2 channels for pulse output of up to 10kHz pulses. Since these two channels can be separately controlled, the FP-e outputalso suitable for 2-axis independent is Pulse Motor positioning. Y0 Pulse output Pulse output
Y2
CW/CCW output Y0

Y2

CW/CCW output

driver 1 Motor Y0Pulse output Y0

Pulse output Y0 Y0 Pulse output

Y2 Y2

driver 1 CW/CCW output CW/CCW output

Motor Motor driver driver 1 1

CW/CCW output Y2 Y2 CW/CCW output Pulse output

MotorMotor driverdriver 1 1

Stepping motor Servo motor Stepping motor Servo motor Motor Motor driver driver 2 2

Y1 Y3

Pulse output CW/CCW output Y1

Y3

CW/CCW output

Motor Pulse output Y1Pulse outputStepping Y1driver 2 Stepping motormotor Motor Servo motor CW/CCW Servo driver 2output CW/CCW output motor

Cutter blade Cutter blade control sign control signal

Pulse output Y1 Y1 Pulse output

Y3 Y3

CW/CCW output Y3 Y3 CW/CCW output

MotorMotor driverdriver 2 2

09/2008

21

XXXXXXXX
xxxxxxxxxxx xxxxx

22

09/2008

fP2 series
Basic CPUs
feaTureS
 Compact body 140 x 100mm (WxH)*
The functions for a medium-scale PLC are squeezed into a compact body which requires minimal installation area for an overall reduction in the device size.

* The five-module type. D: 108.3mm

 Module specifications that allow you to design as you desire


Backplanes for 5, 7, 9, 12, and 14 modules are available, and since the units have the same width, you can choose the most economical design for your application. RS232C port allows connection with operation display panels and host computers, as well as remote surveillance using modems.

 Standard equipped with RS232C port

 Different memory options are available to meet your application


Memory units for comment, calendar timer, expansion RAM, and ROM operation are available so you can add just the options you need.

 Dedicated instructions for high level data processing

Real number data operation is supported, too, enabling you to simplify programs for data processing.

Performance specifications
PLC type Inputs / outputs Built-in memory Program memory capacity No. of instructions Basic instructions High-level instructions Operating speed Operation memory Internal relay (R) Timer/counter (T/C) Data register (DT) File register (FL) Master control relay (MCR) Jump labels (JMP + LOOP) Number of step ladders Number of subroutines Interrupt program Time interrupt Other functions 4048 points 1024 points in total 6000 words 0 to 14,333 words, optionally up to 30,717 words 256 256 1000 stages 100 1 0.5ms to 1.5s Runtime editing, watchdog function, I/O error check, battery, syntax, memory and password functions, test mode, machine code memory, constant cycle time 96 428 0.35s per basic instruction FP2-C1, FP2-C1D, FP2-C1SL Central: max. 1600 (with 25 units) locally expanded: max. 2048 (via MEWNET-F or S-LINK) RAM (EPROM or FROM optional) 16,000 steps, expandable to 32,000 steps

09/2008

23

fP2SH series
Ultra-high performance/Specifications
feaTureS
 Scanning time of 1ms for 20k steps
With an operating speed at the top of its class, super high-speed processing is made possible. The result is a dramatically decreased tact time and high-speed device. Both the large programming capacities of 60k and 120k are available depending on the model. The small PC card is available for programming backup or data memory expansion. This allows data processing of great amounts of data. These functions, options with the FP2, are built right into the FP2SH. The I/O unit and intelligent unit are the same for the FP2 series.

 Large programming capacity of up to 120k steps  Optional small PC card is also available

 Built-in comment and calendar timer functions

THe CPu for iC memory Card inTerfaCe iS aLSo avaiLaBLe


Compact body! The overall dimensions of the 5-unit combination are 140x100x108.3mm (WxHxD).

IC memory card 2MB SRAM

IC memory card 2MB F-ROM

Performance specifications
PLC type Inputs / outputs Built-in memory Program memory capacity No. of instructions Basic instructions High-level instructions Operating speed Operation memory Internal relay (R) Timer/counter (T/C) Data register (DT) File register (FL) Master control relay (MCR) Jump labels (JMP + LOOP) Number of step ladder Number of subroutines Interrupt program Time interrupt Other functions 14,192 points 3072 points in total 10,240 words 32,765 words x 3 banks 256 (1st program: 256 points / 2nd program: 256 points) 256 (1st program: 256 points / 2nd program: 256 points) 1000 100 1 0.5ms to 1.5s Test run operation, forced input/output, interrupt processing, batch conversion, function for multiple instructions in RUN mode, calendar time, computer link and modem control by the TOOL and COM port, IC card, 2MB SRAM, Flash-EEPROM, ROM operation, comment input function 95 434 0.03s per basic instruction FP2-C2, FP2-C2P, FP2-C3P Central: max. 1600 (with 25 units) locally expanded: max. 8192 (via MEWNET-F or S-LINK) RAM (EPROM or FROM and IC memory card optional) FP2-C2, FP2-C2P: 60,000 steps, FP2-C3P: 120,000 steps

24

09/2008

fP2 / fP2SH series


Expansion units and special intelligent units
Power supply units
Part number FP2-PSA1 FP2-PSA2 FP2-PSA3 FP2-PSD2 voltage 100120VAC 200240VAC 100240VAC 24VDC rating (at 5v side) 2.5A 2.5A 5A 5A

input units
i/o number 16 32 64 Part number FP2-X16D2 FP2-X32D2 FP2-X64D2 16 inputs 32 inputs 64 inputs voltage 1224VDC 24VDC 24VDC Connection Screw terminal MIL connector MIL connector

output units
i/o number 6 relays 16 relays voltage 250VAC 250VAC Connection rating Terminal Terminal Connector Connector 5A 2A 0.5A 0.1A 0.1A

16 transistors 1224VDC Terminal 32 transistors 524VDC 64 transistors 524VDC Part number FP2-Y6R FP2-Y16R FP2-Y16T FP2-Y16P FP2-Y32T FP2-Y32P FP2-Y64T FP2-Y64P 6 relay outputs 16 relay outputs 16 transistor outputs NPN 16 transistor outputs PNP 32 transistor outputs NPN 32 transistor outputs PNP 64 transistor outputs NPN 64 transistor outputs PNP

09/2008

25

fP2 / fP2SH series


Expansion units and special intelligent units
i/o mixed units
i/o number voltage Connection rating 0.1A 32 In / 32 Out 1224VDC Connector transistor

An additional input/output mixed unit with ON pulse catch function is available. This useful function makes it possible to read ON pulses with extremly small widths.

Part number FP2-XY64D2P FP2-XY64D7P FP2-XY64D2T FP2-XY64D7T 32 In / 32 Out PNP 32 In / 32 Out PNP pulse catch 32 In / 32 Out NPN 32 In / 32 Out NPN pulse catch

analog input units


Part number FP2-AD8VI inputs 8 input range 10V, 15V 20mA, 4-20mA 100mV, 10V, 1-5V, Thermocouple, RTD Pt100, JPt100, Pt1000

FP2-AD8X FP2-RTD

8 8

analog output unit


Part number FP2-DA4 outputs 4 output range 10V, 020mA

Twenty types of input range such as voltage and temperature sensor are selectable and available for various connection devices (FP2-AD8X). RTD device and thermocouple can be directly connected (FP2-AD8X, FP2-RTD).

High-speed counter unit


Counter Interrupt input Part number 4 channels, max. 200kHz 8 points FP2-HSCP (PNP type) FP2-HSCT (NPN type)

Pulse i/o unit


Counter Interrupt input PWM output Pulse output Part number 4 channels, max. 200kHz 8 points 4 points, 1Hz to 30kHz 4 points, 100kHz FP2-PXYP (PNP type) FP2-PXYT (NPN type)

26

09/2008

fP2 / fP2SH series


Expansion units and special intelligent units
Positioning units
For system-integrated 2 and 4-axis path control. Maximum 4Mpps speed command gives high-speed and high-accuracy positioning. 0.005ms high-speed drive reduces tact time. Feedback pulse count function makes output pulse counting possible for encoders, etc. 4 types of S-curve acceleration / deceleration control make smooth startup and stopping possible.

Part number
FP2-PP21 FP2-PP22 FP2-PP41 FP2-PP42 2 axes, transistor output 2 axes, line driver output 4 axes, transistor output 4 axes, line driver output

rTeX positioning units for minas a4n servo drives


Three types of positioning units allow easy control of network servos with an FP2 PLC. Multi-axis positioning using high speed 100Mbps communications. Reduction in wiring costs with using of commercial LAN cables. Total support from configuration and startup through to monitoring with the dedicated software tool ConfiguratorPM. Includes manual pulser input, allowing support for precision teaching.

Part number
FP2-PN2AN FP2-PN4AN FP2-PN8AN 2-axes positioning unit RTEX 4-axes positioning unit RTEX 8-axes positioning unit RTEX

Serial communication unit


multi communication unit fP2-mCu Detachable interface units make it easy to connect an FP2 PLC to a variety of serial communications devices such as operator terminals, sensor systems, vision systems, temperature controllers, remote maintenance or diagnostic systems or to additional PLCs. Fast communication speeds of up to 230kbps. Communication protocol options including: RS232C, RS422 or RS485 Double isolation of the communications channel. Up to 19 units can be connected in one system. Transmission distance of up to 1200m can be achieved.

09/2008

27

fP2 / fP2SH series


Expansion units and special intelligent units
multi wire-link unit fP2-mw
PLC Link Function: Link communication can be carried out between various programmable controllers using link relays and link registers. Data Transfer Function: PLCs in the same system send and receive information pertaining to contacts and registers, using programs. Remote Programming Function: If the PLCs are in the same system which is connected by the link unit, the programming PLC can be used to program other PLCs, and for monitoring the various contacts and registers.

S-LinK unit fP2-SL2


The S-LINK unit is used by assigning inputs (X) and outputs (Y). The inputs/outputs on the FP2 side that result from these assignments are treated as corresponding to the I/O-adresses (S-LINK I/O-devices in the S-LINK). It controls up to 2048 remote I/Os per FP2 system.

fieldbus master units


The expansion Fieldbus Master Units (FMU) allow you to integrate FP2 PLCs into your network with a maximum degree of flexibility. Wide range of connectivity solutions for FP2/FP2SH One PLC hardware platform for several bus systems Gateway function between fieldbus types simply by connecting the corresponding expansion units to the same CPU

Part number
FP2-DPVI-M FP2-DEV-M FP2-CAN-M Master unit for PROFIBUS Master unit for DeviceNet Master unit for CANopen

flexible network slave unit


Detachable network units make it easy to connect an FP2 PLC to a variety of networks, e.g. PROFIBUS, DeviceNet or CANopen as a slave. Multiple units can be connected to an FP2 CPU. The number of the units is limited by the current consumption only. The change to another network is a matter of minutes. Only a new FPWIN Pro function block is needed for each network type.

Part number
FP2-FNS AFPN-AB6200 AFPN-AB6201 AFPN-AB6218 FP2 FNS expansion unit PROFIBUS plug-in unit DeviceNet plug-in unit CANopen plug-in unit

28

09/2008

fP web-Server
Safe, easy and cost-effective M2M communication
wordwide CommuniCaTionS
The FP Web-Server unit connects all FP-series controllers to the Ethernet. No changes to the PLC programs are necessary. Simply assign an IP address to the FP Web-Server and connect the PLC to the FP Web-Server via the serial RS232C interface. A standard browser, e.g. MS Internet Explorer, can be used for access at the PC. Configuration of the unit is easily done with the FP Web Configurator Tool, which has to be ordered once separately. fP web-Server main features: web-Server: PLC data presented as HTML pages Access via standard Internet browser HTML entry field for PLC data change Optional password protection Java applet functions library email: PLC can send Emails, also with PLC data attachments Email server access via LAN or Internet dial-up PLC defined or pre-stored mail text rS232C device server: Ethernet RS-232C conversion (MEWTOCOL) Transparent RS232C data tunnelling via Ethernet Programming and visualization access via Ethernet modem / ethernet gateway: FP Web-Server can be dialed up via modem for local or network access One remote gateway for multiple FP Web-Servers in a local Ethernet network Remote password handling modbus-TCP communication: Modbus-TCP server or client for a PLC Modbus-TCP server for multiple PLCs Modbus-TCP server gateway for Modbus-RTU slave unit(s) Modbus-TCP client gateway for any Modbus-RTU master Modbus-TCP master or slave interface for a PLC other functions: XML file delivery for PLC data exchange Network time server functions Part number
FP Web-Server Licence to upgrade an FP Web-Server to an IEC60870 Communicator FP Web Configurator Tool FPWEB2 Flash memory IEC60870LIS RAM memory Compliance with standards Dimensions (WxHxD)

fP web-Server advantages: Uses existing Intranet, saves wiring Uses standard browser, saves Scada software Remote control Remote monitoring Remote programming Alarm information via Email Interface / protocol converter

ieC60870 CommuniCaTor
Based on the same hardware as the FP Web-Server safe and easy telecontrol with FP-series PLCs using the widespread IEC 60870-5 telecontrol standard is possible. Thus remote process stations can easily be linked to supervisory control systems or telecontrol main stations. The IEC60870 Communicator supports both IEC 60870-5-101 communication via RS232C or modem and IEC 60870-5-104 communication via Ethernet in one unit.

Specifications
Operating voltage Current consumption LEDs Ambient temperature Ethernet connection PLC connection Modem connection Protocols and standards 24VDC (10.8 to 26.4VDC) 75mA Power, COM Ethernet connection, COM data exchange 0 to +55C Ethernet-COM: 100 BaseTX (via RJ 45 connector) PLC COM: RS232C (via 3-pin Phoenix screw terminal) Modem COM: RS232C (via 9-pin SUB-D with RTS, CTS) TCP/IP, UDP/IP, DHCP, FTP, TELNET, HTTP, SMTP, PPP, XML, IEC60870-5-101, IEC60870-5-104, Modbus-TCP 8 MB 8 MB CE, UL, cUL 25 x 90 x 64mm

FPWEBTOOL2

09/2008

29

fP modem-eu
Telecontrol
fP modem-eu
The FP Modem-EU is a universal device offering not only dial-up communication but also dedicated/leased line and multidropdedicated line communication. Also ASCII text facsimiles can be easily created without special fax software. A short text message (SMS) can be sent using special function blocks designed for the Control FPWIN Pro PLC programming software. Special features of the fP modem-eu for industrial telecontrol: Very small size Operating voltage 24VDC Attachable to a 35mm DIN rail Password protection and call back function Leased line mode (pier-to-pier) Multidrop-leased line mode according to V.23 at 1200 bps DCD output for connection to the digital input of a PLC DTMF-send function and DTMF-receive function for a simplified telecontrolling ASCII fax mode CLIP decoder for calling line identification Using the FP Web-Server (see previous page) there are different strong features which can be accomplished in combination with the FP Modem-EU. Compliant and certified, the CTR21 modem can be used in the following countries: Belgium, Denmark, Germany, Finland, France, Greece, Ireland, Iceland, Italy, Luxembourg, Netherlands, Norway, Austria, Portugal, Sweden, Switzerland, Spain, United Kingdom. The modem is not licensed for the US. User libraries make the integration of communication functions into PLC programs easy, saving programming time and money. Mistakes can be avoided by using well proven function blocks and program examples created by experienced programmers, e.g. Panasonic CONTROL LIBRARY MODEM (NCL-CM-LIB).

Specifications
Part number Operating voltage Current consumption LEDs Ambient temperature Connection to PLC, PC or FP Web-Server Connection to the telephone network Carrier detect connection Error correction Data compression Dialing method Control / Operation Operation modes DTE speed (RS232C baud rate) Line transmission speed Compliance with standards Dimensions (WxHxD) FPMODEMEUD 24VDC (16.6 to 26.4VDC) Approx. 90mA / max. 120mA Power, DCD (Carrier detect) 0 to +55C RS232C (Sub-D 9-pin female) RJ12 jack and RJ12 - RJ12 cable, national adapter is not enclosed 3-pin Phoenix screw terminal port plug V.42, LAPM, MNP4 V.42bis and MNP5 Pulse dialing, tone dialing (DTMF) Extended AT command set, Hayes compatible Automatic selection, V.17, V.21, V.22, V.23, V.22bis, V.27, V.29, V.32, V.32bis 600, 1200, 2400, 4800, 9600, 14,400, 19,200, 38,400, 57,600, 115,200 bps 14,400 bps, 300 (V.21) to 57,600 bps (V.32bis and V.42bis compression, depending on the type of data) CTR21 for PSTN CTR15 for dedicated / leased line CE 25 x 90 x 64mm EN60950 EN50082-2 EN50081-1 Electric safety Industrial E.M. immunity domestic E.M. emission

30

09/2008

Control fPwin Pro


Programming according to the international standard IEC 61131-3
FPWIN Pro is the Panasonic programming software developed according to the international standard IEC 61131-3 (for Windows 98, NT V4.0, 2000, ME or XP). The current version is a result of experience gained over many years. We were one of the first PLC manufacturers to offer an IEC 61131-3 programming software, and we are a leading member of the international organization PLCopen.
Input and output variables are defined once in the global variable list Multiple address assigment is caught automatically by the compiler Type safe programming using simple or complex data types

Comfortable programming in the graphical LD editor (ladder diagram)

Functions can be saved in libraries for future reuse One instruction for different data types (overloaded instructions) Navigator with tree representation of called functions provides an overview even for very complex projects Long variable names make the program self-explanatory

The SFC editor (Sequential Function Chart) allows you to easily visualize processes

Additional window for monitoring and forcing variables

Special functions for controlling the SFC program from another program

Using alliases names for PLC-independent access on the special data registers, e.g. RTC Structuring with selection statements The ST editor (Structured Text) solves complex programming tasks

Using loops for running through incoming data

Using STRING functions for analyzing incoming data or for generating formatted output strings

Easy handling of formulas and arithmetic expressions

free demonstration disc

The most important highlights at a glance: One software for all FP-series PLCs 5 programming languages (instruction list, ladder diagram, function block diagram, sequential function chart, structured text) available for all PLCs Program organization units, task and project management provide clear structure. Reuse of ready-made functions and function blocks saves time for programming and debugging. Online monitoring and diagnostics Part numbers: Forcing turning off input and output contacts via the PC FPWINPROF: Full version supports all FP-series PLCs Modem and Ethernet communication for remote programming, service and diagnostics FPWINPROS: Small version, Extensive comments online documentation created hand in hand with the program supports FP-e, FP0, 6 languages are supported: English, German, French, Italian, Spanish and Japanese. FP-X and FPS (Sigma)
09/2008

31

fP oPC Server
Standardized connection to SCADA/HMI software
ConneCTS your favoriTe induSTriaL aPPLiCaTion To THe fP-SerieS PLCS
The Panasonic OPC server allows high-performance data transfer between applications supporting the universally accepted OPC DA Standard (v1-v3) and Panasonic FP-series PLCs.

Navigator pane shows the hierarchical structure of channel, device and tag group elements.

Tag pane shows the tag elements in a list structure. Multiple rows can be selected and changes applied to all selected elements.

System log pane displays information, warnings and error event messages.

Server staus pane shows actual status information about the server application, e.g. server time, up time, connected clients and number of tags.

feaTureS of THe fP oPC Server


Modern and intuitive user interface allows you to configure the server. While creating the application, sophisticated user assistance and help is omnipresent. The server complies to the following OPC DA client/server technologies: OPC DA 1.0a OPC DA 2.05a OPC DA 3.0 The PLCs can be accessed via serial, modem and Ethernet communication lines. State-of-the-art import / export mechanism allows you to save, exchange or edit data in XML format. Data can also be exchanged with other Panasonic software products, e. g. FPWIN Pro, using a CSV file. An icon or tool tip notifies the user about possible errors in configuration. The FP OPC Server allows you to clearly structure your application, e.g. by grouping elements in meaningful hierarchies. Tolerant of interruptions: if a connected device stops responding, e. g. because the line is interrupted, the communication is carried on for the other connected devices.

Part number
FP OPC Server software with one license Additional FP OPC Server license AFPS03510D AFPS03517D

32

09/2008

fP data analyzer
Read and display PLC data
The FP Data Analyzer is a software tool for acquisition, logic analysis and representation of recorded data on multiple channels connected to any Panasonic PLC. The software is a stand-alone tool. You need not install any other software to run the FP Data Analyzer.

The FP Data Analyzer can be connected to any Panasonic PLC by utilizing the integrated MEWNET Manager, for instance via any COM port. Recording and analyzing remote PLCs, sensors, actuators, etc. via LAN or modem is just a matter of seconds. In addition, not only PLCs can be analyzed with the FP Data Analyzer! Via the integrated OLE interface, the P500 image processing software can also send samples to the analyzer.

feaTureS of THe fP daTa anaLyZer


LAN and modem connection for remote control via LAN, Internet or telephone line Concurrent data acquisition from several independent PLCs Acquisition of all internal and external PLC registers, relays, counters, timers, arrays and even DUTs Connection to P500 image processing software Data types can be recorded and displayed as: BOOL, INT, DINT, WORD, DWORD, REAL, STRING, ARRAY of type. Adding new channels while recording Variable list compatible to FPWIN Pro GVL export Trigger functions with pre-trigger, post-trigger User-defined sampling rate from a few milliseconds to hours or even days Each channel can be displayed in any color and trace width. Display signals graphically as single channels, in XY-mode or in tables Time measuring function with up to 4 markers plus 2 trigger markers Jump to time Jump to an analog value Virtually unlimited number of samples Part number
FP Data Analyzer software AFPS04510D

09/2008

33

Control CommX
The connection in ActiveX technology
Connects your visual Basic application to Panasonic PLCs
feaTureS
 No need for knowledge of Panasonics PLC communication Protocol (MEWTOCOL). Communication programs can be made simply by dropping a Control on to a form.  Ethernet or modem connection is possible. Can be started simply by inputting a command.  Your own application and Panasonic software can communicate at the same time. Length of time for starting is shortened drastically by using Panasonic PLC software.

SeTuP ProCeSS

Initial setup in Visual Basic

Configuration of communication

Register of various communication types

Programming

Part number
Control CommX software with USB port dongle AFW20031

PCway data monitoring, logging and setting software based on excel


PCWAY is a unique add-in software for Microsoft Excel. With PCWAY, it is possible to display PLC data on the Excel sheet. Thereby animated visual displays are possible. It is also possible to display internal matters, such as accumulating data on a file, or a sound. A trigger, which can be a relay or an event, can be used to start such internal tasks. When the trigger changes from OFF to ON, the internal processing tasks start.

feaTureS
Real time display of the PLC memory area in the Excel cell Changing the PLC memory area directly from the Excel cell Saving the PLC data on the file and displaying the data that have been saved in the file Booting Excel macros automatically By combining the macro with PCWAY, it is possible to automatically generate reports or to change the colors of the charts based on the PLC information. Email function PCWAY monitors internal relays of the PLC and sends the equipment status information to a PC or a cellular phone via e-mail when the internal relay changes from OFF to ON. Part number
PCWAY software with USB port dongle USB port dongle for PCWAY and CommX AFW10031 AFW1033

34

09/2008

Completion

other factory automation Products


Product overview
fa ComPonenTS
Components such as Eco-power meters, timers/counters, temperature controllers, limit switches and fans round off our wide Factory Automation product range.

oPeraTor TerminaLS (gT)


GT touch terminals are available in different sizes and colors, and with different features. With Panasonic touch terminals, projects can be designed flexibly, quickly and in many languages.

Servo driveS
Panasonic servo drives enable high performance motion control to be applied to almost all types of machines, including chip mounting machines and general industrial machines.

inverTerS
Easy to operate, ultra compact inverters offer cost-effective solutions for simple speed control up to sophisticated motion control applications.

LaSer marKing SySTemS


SUNX laser markers are ideal for non-contact, permanent labelling of most materials, e.g. plastics, glass, paper, wood and leather. Several CO2 laser marking systems and a unique FAYb laser marker can be easily integrated into existing production systems for a great variety of labelling tasks.

SenSorS
SUNX is the brand name for our sensor products. Whatever type of sensor is required, our wide product range offers you the right solution.

maCHine viSion SySTemS


Panasonic offers the complete range of high quality industrial Machine Vision Systems. From the easy Vision-Sensor to the high-end inspection machine, 100% quality inspection and process control is assured.

09/2008

35

global network

North America

Europe

Asia Pacific

China

Japan

Panasonic electric works


Please contact our Global Sales Companies in:
Europe Headquarters Austria Panasonic Electric Works Europe AG Panasonic Electric Works Austria GmbH PEW Electronic Materials Europe GmbH Benelux Czech Republic France Germany Hungary Ireland Italy Panasonic Electric Works Sales Western Europe B.V. Panasonic Electric Works Czech s.r.o. Panasonic Electric Works Sales Western Europe B.V. Panasonic Electric Works Deutschland GmbH Panasonic Electric Works Europe AG Panasonic Electric Works UK Ltd. Panasonic Electric Works Italia srl
Rudolf-Diesel-Ring 2, 83607 Holzkirchen, Tel. +49 (0) 8024 648-0, Fax +49 (0) 8024 648-111, www.panasonic-electric-works.com Rep. of PEWDE, Josef Madersperger Str. 2, 2362 Biedermannsdorf, Tel. +43 (0) 2236-26846, Fax +43 (0) 2236-46133 www.panasonic-electric-works.at Ennshafenstrae 30, 4470 Enns, Tel. +43 (0) 7223 883, Fax +43 (0) 7223 88333, www.panasonic-electronic-materials.com De Rijn 4, (Postbus 211), 5684 PJ Best, (5680 AE Best), Netherlands, Tel. +31 (0) 499 372727, Fax +31 (0) 499 372185, www.panasonic-electric-works.nl Prumyslov 1, 34815 Plan, Tel. (+420-)374 799 990, Fax (+420-)374 799 999, www.panasonic-electric-works.cz Succursale franaise, 10, rue des petits ruisseaux, 91370 Verrires Le Buisson, Tl. +33 (0) 1 6013 5757, Fax +33 (0) 1 6013 5758, www.panasonic-electric-works.fr Rudolf-Diesel-Ring 2, 83607 Holzkirchen, Tel. +49 (0) 8024 648-0, Fax +49 (0) 8024 648-555, www.panasonic-electric-works.de Magyarorszgi Kzvetlen Kereskedelmi Kpviselet, 1117 Budapest, Neumann Jnos u. 1., Tel. +36 (0) 1482-9258, Fax +36 (0) 1482-9259, www.panasonic-electric-works.hu Dublin, Tel. +353 (0) 14600969, Fax +353 (0) 14601131, www.panasonic-electric-works.co.uk Via del Commercio 3-5 (Z.I. Ferlina), 37012 Bussolengo (VR), Tel. +39 (0) 456752711, Fax +39 (0) 456700444, www.panasonic-electric-works.it Building Materials Division, Piazza della Repubblica 24, 20154 Milano MI, Tel. +39-02-2900-5391, Fax +39-02-2900-3466 Sjngsvgen 10, 19272 Sollentuna, Sweden, Tel. +46 859476680, Fax +46 859476690, www.panasonic-electric-works.se Citadellsvgen 23, 21118 Malm, Tel. +46 40 697 7000, Fax +46 40 697 7099, www.panasonic-fire-security.com Al. Krakowska 4/6, 02-284 Warszawa, Tel. +48 (0) 22 338-11-33, Fax +48 (0) 22 338-12-00, www.panasonic-electric-works.pl Portuguese Branch Office, Avda Adelino Amaro da Costa 728 R/C J, 2750-277 Cascais, Tel. +351 214812520, Fax +351 214812529 Barajas Park, San Severo 20, 28042 Madrid, Tel. +34 913293875, Fax +34 913292976, www.panasonic-electric-works.es Grundstrasse 8, 6343 Rotkreuz, Tel. +41 (0) 41 7997050, Fax +41 (0) 41 7997055, www.panasonic-electric-works.ch Sunrise Parkway, Linford Wood, Milton Keynes, MK14 6 LF, Tel. +44 (0) 1908 231555, Fax +44 (0) 1908 231599, www.panasonic-electric-works.co.uk

Panasonic Electric Works Italia Srl Nordic Countries Panasonic Electric Works Nordic AB PEW Fire & Security Technology Europe AB Poland Panasonic Electric Works Polska sp. z o.o Portugal Panasonic Electric Works Espaa S.A. Spain Panasonic Electric Works Espaa S.A. Switzerland Panasonic Electric Works Schweiz AG United Kingdom Panasonic Electric Works UK Ltd. North & South America USA PEW Corporation of America

629 Central Avenue, New Providence, N.J. 07974, Tel. 1-908-464-3550, Fax 1-908-464-8513, www.pewa.panasonic.com

Asia Pacific / China / Japan China Hong Kong Japan Singapore Panasonic Electric Works (China) Co., Ltd.
Level 2, Tower W3, The Towers Oriental Plaza, No. 2, East Chang An Ave., Dong Cheng District, Beijing 100738, Tel. (010) 8518-5988, Fax (010) 8518-1297 RM1205-9, 12/F, Tower 2, The Gateway, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong, Tel. (0852) 2956-3118, Fax (0852) 2956-0398

Panasonic Electric Works (Hong Kong) Co., Ltd. 1048 Kadoma, Kadoma-shi, Osaka 571-8686, Japan, Tel. (06) 6908-1050, Fax (06) 6908-5781, www.mew.co.jp/e-acg/ Matsushita Electric Works, Ltd. Panasonic Electric Works Asia Pacific Pte. Ltd. 101 Thomson Road, #25-03/05, United Square, Singapore 307591, Tel. (06255) 5473, Fax (06253) 5689

 

09/2008

Copyright2008PrintedinGermany 4104euen08/08

Das könnte Ihnen auch gefallen