Service protection

Example with CESoP

Giulio Cavalli MWR SA 29-12-2010

For internal use only 1 Nokia Siemens Networks

Presentation / Author / Date

History

Date 19/11/2010 29/12/2010

Changes First issue Update of slide Configurations: CCI value and description

For internal use only 2 Nokia Siemens Networks

Presentation / Author / Date

Reference scenario

A1200 - A
Main path

A1200 - B A1200 - D

A1200 - C
Protection path

For internal use only 3 Nokia Siemens Networks

Presentation / Author / Date

Service creation
Service is created exactly as without protection
See CESoP service - 1xE1.ppt or CESoP service - nxE1.ppt or E-Line service.ppt

In the following, CESoP service - 1xE1.ppt is assumed


already configured

In addition protection path is configured as follow

For internal use only 4 Nokia Siemens Networks

Presentation / Author / Date

End points
LCT Menu: LCT Menu: Services Create Protection A1200-A

A1200-C

For internal use only 5 Nokia Siemens Networks

Presentation / Author / Date

Configurations
Ref. 1 2 3 4 5 6 7 8 Parameter Protection type MEP ID local main MEP ID remote main MEP ID local stand-by MEP ID remote stand-by MA name main MA name stand-by CCI Value in A1200-A Protected 1 2 1 2 60 61 100ms Value in A1200-C Protected 2 1 2 1 60 61 100ms Notes Monitor is just used for collecting statistics, not for protection It could be the same values for all the protected services It could be the same values for all the protected services It could be the same values for all the protected services It could be the same values for all the protected services Constraint is that MA name and stand-by are different. General rule is to use the S-VID Constraint is that MA name and stand-by are different. General rule is to use the stand-by S-VID This is the interarrival time of the monitoring messages. They are used for service performance monitoring. This value does not determine the switching time, since for CESoP service the protection switch is triggered by the absence of the data packets. This is the common setting Its the time that shall pass before the main link is switched back (if available) It shall be different from any other service.

9 10 11 12 13

Revertive/unrevertive Reversion timeout Service VLAN ID Stand-by Module Stand-by Port

Revertive 60 61 Module 0 6

Revertive 60 61 Module 0 4

For internal use only 6 Nokia Siemens Networks

Presentation / Author / Date

Middle point
LCT Menu: LCT Menu: Services Create

For internal use only 7 Nokia Siemens Networks

Presentation / Author / Date

Middle point configurations


Ref. Parameter Value in A1200-D E1-1-stby E-Line 61 1xE1_8fr NNI Module 0 5 NNI Module 0 6 Ethernet module Typically connected to FPR Ethernet module Typically connected to FPR Notes

14 15 16 17 18 19 20 21 22 23

Description Service type Service VLAN ID Profile name First Port First Port module First Port port First Port First Port module First Port port

Any value that describe the service For creating intermediate service protection carrying CESoP S-VID that identify the service protection in the transport network Profile to be associated to the service. For services contain more than 1xE1 a proper profile shall be associated.

For internal use only 8 Nokia Siemens Networks

Presentation / Author / Date