Sie sind auf Seite 1von 4

HYKON GROUP COMPANIES

file:///E:/Project/28.7.12/HYKON GROUP COMPANIES.htm

Company Profile Group Companies Awards CSR Media Room Clientele Partners

1. What is power Quality? Power Quality is the interaction of electronic equipments with its electrical environment, including generators, transformers, breakers and electrical wiring and grounding.The term Power Quality broadly refers to maintaining a near sinusoidal power distribution bus voltage at rated magnitude and frequency. In addition the energy supplied to a customer must be uninterrupted from the reliability point of view. 2. How is Power Quality measured? Power Quality is measured by the consistency of the voltage supplied at your meter. The amount of voltage available may fluctuate or change due to controllable or uncontrollable circumstances. The measure of power quality depends up on the needs of the equipments that are being supplied. 3. Why is power quality such a problem today? In recent years there has been an increased use of non linear loads which has resulted in an increased fraction of non sinusoidal voltages and currents in electrical network. Therefore power quality problems to day are more frequent and costly than ever before, despite the overall improvements in electricity reliability.

Customer Care & Support AMC Service Centers

Power Electronics Solar FAQ Downloads

Careers What we offer ? Job Openings

4. What terms are commonly used in the measurements and descriptions of power quality? Voltage sags/swells Voltage dips Voltage distortion Voltage unbalance Voltage interruption Voltage flicker Impulse or surge Harmonics
Go to T op

Quote / Enquiry Customer Support Hykon Offices Site Feedback Company Profile Group Companies Awards CSR Media Room Clientele Partners

5. List out the power quality problems and causes? Broad Categories Specific Categories
Impulsive

Characterization Methods Typical Causes

Peak magnitude, rise time and duration


Transients Oscillatory

Lighting strike, Transformer energisation and capacitor switching

Peak magnitude, Frequency components

Line or Capacitor or Load Switching

Customer Care & Support AMC Service Centers

Sag

Magnitude duration

Ferro resonant transformers Single line to ground fault

Power Electronics Solar FAQ Downloads

Swell Short duration voltage variation

Magnitude duration

Ferro resonant transformers Single line to ground fault

Careers What we offer ? Job Openings

Interruption

Duration
Quote / Enquiry Customer Support

Temporary (self Clearing faults)

1 of 5

7/29/2012 8:45 PM

HYKON GROUP COMPANIES

file:///E:/Project/28.7.12/HYKON GROUP COMPANIES.htm

Hykon Offices Site Feedback Company Profile Group Companies Awards CSR Media Room Clientele Partners

Under voltage

Magnitude duration

Switching on loads, Capacitor de-energisation

Long duration voltage variation Over voltage

Magnitude duration
Customer Care & Support AMC Service Centers

Switching off loads, Capacitor energisation

Power Electronics Solar FAQ Downloads

Voltage Unbalance

Symmetrical components

Single-phase load, Single phasing condition

Harmonics

THD, Harmonic spectrum


Careers What we offer ? Job Openings

Adjustable speed drives and non linear loads

Waveform distortion Notching

THD, Harmonic spectrum


Quote / Enquiry Customer Support Hykon Offices Site Feedback

Power Electronics converter

Voltage Flicker

Frequency of occurrences, modulating frequency

Arc furnace, Arc Lamps

Go to T op

6. What kind of equipments can be affected by power quality problems? Any type of electrical equipment can be affected by power quality problems. However the most costly power quality problems involve more sensitive high tech equipments, such as computer and data systems, which can be affected by their direct power supply or through interactions with other electrical equipments. 7. Are power quality problems are always noticeable? No in many cases disturbances can cause damage to circuits and other components. Unfortunately many power quality problems go unsolved until a significant monetary loss is actualized, and even then masked problems like failed electrical or electronic equipments hide the underlying power quality problems tat are the root cause of these failures. 8. What causes power quality problems? Most power quality problem causes can be divided into two categories internal and external.
Internal factors: faults o lightning strikes on transmission lines or distribution feeders, equipment failures etc External factors: Transformer energisation. Capacitor or feeder switching, Power electronic loads, Arc furnace and induction heating systems switching on or off of large loads etc.

9. What are the types of electronic irregularities that cause power quality problems? Outage or Interruptions: An outage is a complete loss of voltage; it usually lasts for a few cycles to several hours. Ice storms, lightening or winds are some of the more typical causes of power failures. As different loads having different requirements, there is no universal standard for power acceptability considering outages. Voltage sags or under voltage A drop is service voltage below the proper nominal operating low voltage limit for several seconds in duration is an under voltage condition. Voltage sag may be caused by faults in the transmission system or by the switching loads with the large amount of initial starting / inrush current. Voltage swell or Over Voltage It is a steady state voltage for several seconds or longer which is above the upper source voltage limit. Over

2 of 5

7/29/2012 8:45 PM

HYKON GROUP COMPANIES

file:///E:/Project/28.7.12/HYKON GROUP COMPANIES.htm

voltage usually occurs due to improper adjustments of voltage regulators, capacitors etc. Line to ground fault in a three phase system may cause voltage swell in the un faulted phases. Surges or impulses: Surge is a transient voltage or current that can have a high magnitude for extremely shot duration. Causes include lightning, normal operation of utility protection devices, equipment start up and shut down, welding equipments. While lightning generates most impressive transients, switching large motors and transformers or capacitor creates transients sufficient o destroy todays delicate microprocessor based equipments. Harmonics The periodic steady state distortions of the standard sine wave due to equipment generating a frequency other than the standard 50 cycles per second. Causes include electronic ballasts, non linear loads like switch mode power supplies used in computers, variable frequency drives. In general harmonics cause magnetic portions of the electrical system to over heat. Such as transformers, line reactors, magnetic relays and power factor capacitors Flicker Flicker can be defined as the perceptible change in lamp output produced by a sudden change in supply voltage. Some of the loads like arc furnace load undergo rapid changes and generates variable voltage dip along the distribution feeder. The disturbance may affect some of the loads like incandescent lighting. 10. How is power quality problems diagnosed? Electrical engineers and technical team use sophisticated monitoring and testing to isolate the specific type of disturbances and pinpoint the root cause. Examples of the testing that can be used include harmonic studies, load studies, disturbance monitoring, wiring and grounding studies and power factor measurements.
Go to T op

11. How do I know a certain problem is caused by power quality issues? Determining the exact problems related to power quality issues requires sophisticated electronic test equipments. The following questions are general indicators of power quality problems. Are you experiencing premature failures of electronic equipments or motors or drives? Do you have adjustable speed drives that frequently trip off-line? Do your computers lock up inexplicably? Does your computer monitor screens jitter? Do you have equipments problems during or shortly after lightning storms? Is interruptible power supplies frequently go to battery? Are circuit breakers tripping without being overloaded? Are transformers caught extremely hot to the touch? Do equipments frequently malfunction at the same time of the day? Do automated systems fail for no apparent reason? Do certain electronic systems work in one location but not in another location? Do light dim or flicker? 12. How is power quality problems fixed? The solution to a power quality issue depend on the nature of the problem, but may include the installation of power conditioning devices such as uninterruptible power supplies, transient voltage surge suppressors or isolation transformers. Other potential solutions include facility rewiring or replacement of damaged or degraded equipment. 13. How do I perform a power quality audit of my business? The objective of a power quality audit is to find a solution to a problem. This is accomplished by checking the wiring and grounding, which causes a significant amount of most commercial and industrial problems, and checking the quality of both the internal and external voltage. This data is then used to determine an appropriate solution. In conducting an audit, the power quality professional must find answers to four questions viz; Does the facilities wiring and grounding meet code and more importantly is it adequate to meet their power needs from a power quality stand point? What is the quality of the ac voltage supplying the equipment? What is the impact of electric utilities power system? What solutions are indicated by the audit data? The last question off course is the most important. The best out come of any power quality audit is whether the problem was solved or not.
Go to T op

14. Is there a solution to the power quality problem? Yes. HYKON UPQC can solve all the power quality problems Hykon Power Quality Products Power factor, voltage UPQC - Unified sags/swells, voltage Power Quality interruptions, over voltage, Conditioner under voltage Power Quality Issues Benefits Regulates load voltage against sag/ swell and other voltage fluctuations. Individual phase compensation of the load voltages to eliminate voltage unbalance

3 of 5

7/29/2012 8:45 PM

HYKON GROUP COMPANIES

file:///E:/Project/28.7.12/HYKON GROUP COMPANIES.htm

Reactive current filtering by STATCOM Maintains Grid Power Factor near to unity and brings down Maximum Demand ( MD) Uninterrupted production and supply

15. What is UPQC? UPQC stands for Unified Power Quality Conditioner. UPQC is an active series / shunt power line conditioner. It is used to compensate power quality issues such as Voltage sags, swells, Voltage imbalance, flicker, harmonics and reactive current. It is a combination of a STATCOM as well as a series compensating stage connected before the load in series with the power network using a matching transformer. 16. What is the basic function of UPQC? Load voltage regulation be series voltage injection Dynamic current Injection for reactive power compensation UPQC is used to compensate voltage sags and current harmonics, control input power factor near to unity as well as to regulate the load voltage. It can be installed by the electric utilities to damp out harmonic propagation caused by resonance with line impedance and passive shunt compensators. 17. What is the basic topology of UPQC? UPQC consists of 1 x 3 phase and 3 x 1 phase Voltage source converters sharing the same capacitive DC link. The 3 phase converter will act as an Active Filter while the other is a series filter (Dynamic Voltage Regulator) The basic block diagram of a UPQC is shown below:

18. What is the role of Series Active Filter and Shunt Active Filter in UPQC? The Shunt Active Filter is primarily a Voltage Source Converter connected to Point of Common Coupling (PCC) through series inductors. The Series Filter (DVR) is primarily a Voltage Source Inverter connected to Power network with LC filter and isolation transformer. The secondary of the transformer is connected in series with Power Network. 19. Where UPQC can be installed? IT Parks Commercial Office Complexes Semiconductor industries Machine Tool plants Process Industries 20. Can I use a Power Conditioner instead of UPS? Your question involves two different technologies used for differing reasons. 95% of all power quality problems are caused by transient noise, voltage surges, harmonics or frequently changing voltage conditions. Unified Power Quality Conditioner provides solution for most of the power quality problems.The primary function of any uninterruptible power supply ( UPS) is to provide an alternate voltage source ( batteries) to a critical load for some period of time should a complete power failure occur. Complete power failure accounts less than 5% of all power quality problems. For the other 955 of all the power quality problems unless the UPS is the on-line version is of no help. 21. Does the UPQC need much on going service and maintenance? No. Depending up on the environment that the HYKON UPQC located only preventive maintenance would be required and that involves ensuring that the door and internal fans are fully operational and that all filters are free of dust and not blocked. 22. Is the technology is developed by HYKON? The technology is transferred from CDAC which is a project supported by Dept of IT, Ministry of Communication and Information Technology, Govt. of India and manufactured at HYKON. 23. Whether the HYKON UPQC technology field proven? Yes. The 250 KVA proto model of UPQC is working in the Power Electronics Lab of C DAC Thiruvananthapuram with light and fan loads of the centre connected for the past one year. 24. My question is not on the list how can I get an answer to my question? Please go to our FAQ form. We will answer your questions directly as quickly as possible.