Alarm Reference
Issue Date
02 2012-05-24
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Issue 02 (2012-05-24)
Change History
Change History
Change History
Changes between document issues are cumulative. Therefore, the latest document issue contains all changes made in previous issues.
Issue 02(2012-05-24)
Changes compared with version 01 (2012-03-05) are as follows: Revise contact information.
Issue 01 (2012-03-05)
Initial field final release.
Issue 02 (2012-05-24)
ii
Contents
Contents
Change History ................................................................................................................................ ii 1 Alarm Reference ............................................................................................................................ 1
1.1 linkDown_1.3.6.1.6.3.1.1.5.2 linkDown .......................................................................................................... 1 1.2 linkUp_1.3.6.1.6.3.1.1.5.3 linkUp .................................................................................................................... 2 1.3 hwOpticalRemove _1.3.6.1.4.1.2011.5.25.219.2.4.1 hwOpticalRemove ......................................................... 3 1.4 hwOpticalInsert _1.3.6.1.4.1.2011.5.25.219.2.4.2 hwOpticalInsert ................................................................. 4 1.5 hwOpticalPowerAlarm _1.3.6.1.4.1.2011.5.25.219.2.4.7 hwOpticalPowerAlarm........................................... 5 1.6 hwOpticalPowerAlarmResume_ 1.3.6.1.4.1.2011.5.25.219.2.4.8 hwOpticalPowerAlarmResume ................. 6 1.7 CPU_1.3.6.1.4.1.2011.5.25.219.2.14 hwCPUTrap .......................................................................................... 7 1.8 STP _1.3.111.2.802.1.1.3.0.1 newRoot ............................................................................................................ 8 1.9 STP_1.3.111.2.802.1.1.3.0.2 topologyChagne ................................................................................................. 9 1.10 lldpRemTablesChange 1.0.8802.1.1.2.0.0.1 ................................................................................................. 10 1.11 lldpXMedTopologyChangeDetected 1.0.8802.1.1.2.1.5.4795.0.1 ............................................................... 11 1.12 coldStart_1.3.6.1.6.3.1.1.5.0......................................................................................................................... 12 1.13 warmStart_1.3.6.1.6.3.1.1.5.1 ...................................................................................................................... 13 1.14 authenticationFailure 1.3.6.1.6.3.1.1.5.4 ...................................................................................................... 13 1.15 hwFanInvalid_ 1.3.6.1.4.1.2011.5.25.219.2.6.5 ........................................................................................... 14 1.16 hwFanInvalidResume _ 1.3.6.1.4.1.2011.5.25.219.2.6.6 ............................................................................. 15 1.17 hwBrdTempAlarm _ 1.3.6.1.4.1.2011.5.25.219.2.10.13 .............................................................................. 16 1.18 hwBrdTempResume _ 1.3.6.1.4.1.2011.5.25.219.2.10. 14 ........................................................................... 17
Issue 02 (2012-05-24)
iii
1 Alarm Reference
1
Description
An Ethernet interface goes Down.
Alarm Reference
Attribute
Alarm ID 1.3.6.1.6.3.1.1.5.2 Alarm Severity Notification Alarm Type -
Parameters
Name ifIndex ifAdminStatus ifOperStatus Meaning Indicates the interface index. Indicates the administrative status of an interface. Indicates the current status of an interface:
Issue 02 (2012-05-24)
1 Alarm Reference
Possible Causes
The administrator has shut down the interface or modified configuration of the interface. The Ethernet interface is disconnected. The administrator has shut down the remote interface or modified configuration of the remote interface. The interface is shut down by a protection function on the switch.
Procedure
Step 1 Check the cable connection on the interface and ensure that the interface is properly connected to the remote interface. Step 2 Check whether the interface has been manually shut down on the Device Information page of the web NMS. If the interface needs to transmit data, start the interface. Step 3 Check whether the interface has been shut down by any of the following functions: Bridge protocol data unit (BPDU) protection Dynamic ARP inspection (DAI) Broadcast storm suppression Port security If so, ignore the alarm. ----End
Related Information
None
Attribute
Alarm ID 1.3.6.1.6.3.1.1.5.3 Alarm Severity Notification Alarm Type -
Issue 02 (2012-05-24)
1 Alarm Reference
Parameters
Name ifIndex ifAdminStatus ifOperStatus Meaning Indicates the interface index. Indicates the administrative status of an interface. Indicates the current status of an interface:
Possible Causes
The Ethernet interface is properly connected to the remote interface using a network cable. A loopback test is performed on the Ethernet interface.
Procedure
None
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.4.1 Alarm Severity Critical Alarm Type equipmentAlarm(5)
Issue 02 (2012-05-24)
1 Alarm Reference
Parameters
Name hwEntityPhysicalIndex entPhysicalName hwEntityTrapFaultID Meaning Indicates the interface index. Indicates the interface name. Indicates the error code. The error code in this alarm is 616.
Possible Causes
The optical model is removed from the interface.
Procedure
None
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.4.2 Alarm Severity Critical Alarm Type equipmentAlarm(5)
Parameters
Name hwEntityPhysicalIndex Meaning Indicates the interface index.
Issue 02 (2012-05-24)
1 Alarm Reference
Meaning Indicates the interface name. Indicates the error code. The error code in this alarm is 616.
Possible Causes
An optical module is installed on the interface.
Procedure
None
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.4.7 Alarm Severity Critical Alarm Type -
Parameters
Name entPhysicalName hwUserDefAlarmName hwEntityTrapFaultID Meaning Indicates the interface name. Indicates the alarm name. Indicates the error code. The error code in this alarm is 617.
Issue 02 (2012-05-24)
1 Alarm Reference
Possible Causes
The optical module is used for long-distance transmission but is connected to a fiber with a short transmission distance.
Procedure
Use an attenuator on the fiber connected to the optical module.
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.4.8 Alarm Severity Critical Alarm Type
Parameters
Name entPhysicalName hwUserDefAlarmName hwEntityTrapFaultID Meaning Indicates the interface name. Indicates the alarm name. Indicates the error code. The error code in this alarm is 617.
Issue 02 (2012-05-24)
1 Alarm Reference
Possible Causes
None
Procedure
None
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.14.1 1.3.6.1.4.1.2011.5.25.219.2.14.2 Alarm Severity Warning Warning Alarm Type hwCPUUtilizationRising hwCPUUtilizationResume
Parameters
Name oid hwEntityPhysicalIndex entPhysicalName hwEntityThresholdType hwEntityThresholdWarning hwEntityThresholdCurrent hwEntityTrapFaultID Meaning Indicate the alarm index. Indicates the device index. Indicates the device name. Indicates the alarm type. Indicates the CPU usage alarm threshold. Indicates the average CPU usage in the last 5 minutes. Indicates the error code. The error code in this alarm is 620.
Issue 02 (2012-05-24)
1 Alarm Reference
Possible Causes
The switch receives a large number of protocol packets because it undergoes an attack, for example a denial-of-service (DoS) attack.
Procedure
Step 1 If the alarm persists for a long time, capture packets on interfaces to check whether the switch receives a large number of protocol packets. Step 2 If an attack occurs, contact Huawei technical support personnel. ----End
Related Information
None
Attribute
Alarm ID 1.3.111.2.802.1.1.3.0.1 Alarm Severity Information Alarm Type newRoot
Parameters
Name oid Meaning Indicate the alarm index.
1 Alarm Reference
Possible Causes
A device is added to or removed from the network. Bridge priorities of some devices are changed.
Procedure
None
Related Information
None
Attribute
Alarm ID 1.3.111.2.802.1.1.3.0.2 Alarm Severity Information Alarm Type topologyChagne
Parameters
Name oid Meaning Indicate the alarm index.
Possible Causes
A device is added to or removed from the network. Bridge priorities of some devices are changed. Some interfaces are disconnected or costs of some interfaces are changed.
Procedure
None
Issue 02 (2012-05-24)
1 Alarm Reference
Related Information
None
Attribute
Alarm ID 1.0.8802.1.1.2.0.0.1 Alarm Severity Information Alarm Type lldpRemTablesChange
Parameters
Name lldpStatsRemTablesInserts Meaning Indicates the number of entries added to the LLDP remote table. The local switch adds an entry when receiving a message from a new neighbor. Indicates the number of entries deleted from the LLDP remote table. The local switch deletes an entry when receiving a message indicating that the corresponding neighbor is shut down. Indicates the number of received messages that are discarded. The local switch discards messages received from neighbors if the storage device has no sufficient space to save the messages. Indicates the number of entries aged out from the LLDP remote table.
lldpStatsRemTablesDeletes
lldpStatsRemTablesDrops
lldpStatsRemTablesAgeouts
Issue 02 (2012-05-24)
10
1 Alarm Reference
Possible Causes
A new neighbor is discovered or the entry matching a neighbor ages out.
Procedure
None
Related Information
None
Attribute
Alarm ID 1.0.8802.1.1.2.1.5.4795.0.1 Alarm Severity Information Alarm Type lldpXMedTopologyChangeDe tected
Parameters
Name lldpRemChassisIdSubtype lldpRemChassisId lldpXMedRemDeviceClass Meaning Indicates the remote device ID type. Indicates the remote device ID. Indicates the remote device type.
Issue 02 (2012-05-24)
11
1 Alarm Reference
Possible Causes
A MED device is added to or removed from the network.
Procedure
None
Related Information
None
1.12 coldStart_1.3.6.1.6.3.1.1.5.0
Description
A coldStart trap signifies that the sending protocol entity is reinitializing itself such that the agent's configuration or the protocol entity implementation may be altered. The switch is powered and started.
Attribute
Alarm ID 1.3.6.1.6.3.1.1.5.0 Alarm Severity Critical Alarm Type -
Parameters
None
Possible Causes
The switch was powered off. A user pressed the reset button.
Procedure
Check the power supply and operating environment of the switch.
Related Information
None
Issue 02 (2012-05-24)
12
1 Alarm Reference
1.13 warmStart_1.3.6.1.6.3.1.1.5.1
Description
A warmStart trap signifies that the SNMP entity, supporting a notification originator application, is reinitializing itself such that its configuration is unaltered. The switch is manually restarted.
Attribute
Alarm ID 1.3.6.1.6.3.1.1.5.1 Alarm Severity Critical Alarm Type -
Parameters
None
Possible Causes
The switch is manually restarted.
Procedure
None
Related Information
None
Issue 02 (2012-05-24)
13
1 Alarm Reference
Attribute
Alarm ID 1.3.6.1.6.3.1.1.5.4 Alarm Severity Information Alarm Type authenticationFailure(5)
Parameters
None
Possible Causes
An authorized user uses an invalid community to access an SNMP node.
Procedure
None
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.6.5 Alarm Severity Warning Alarm Type equipmentAlarm(5)
Parameters
Name hwEntityPhysicalIndex entPhysicalName Meaning Indicates the fan index. Indicates the fan name.
Issue 02 (2012-05-24)
14
1 Alarm Reference
Name hwEntityTrapFaultID
Meaning Indicates the error code. The error code in this alarm is 622.
Possible Causes
The fan is faulty.
Procedure
Replace the fan.
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.6.5 Alarm Severity Information Alarm Type equipmentAlarm(6)
Parameters
Name hwEntityPhysicalIndex entPhysicalName hwEntityTrapFaultID Meaning Indicates the fan index. Indicates the fan name. Indicates the error code. The error code in this alarm is 622.
Issue 02 (2012-05-24)
15
1 Alarm Reference
Possible Causes
The fan is fixed or is replaced with a new one.
Procedure
None
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.6.5 Alarm Severity Warning Alarm Type equipmentAlarm(13)
Parameters
Name hwEntityPhysicalIndex entPhysicalName hwEntityThresholdType Meaning Indicates the device index. Indicates the device name. Indicates the relationship between the device temperature and the alarm threshold. The value is riseOver(1), indicating that the device temperature exceeds the alarm threshold. Indicates the temperature alarm threshold. Indicates the current temperature.
hwEntityThresholdWarning hwEntityThresholdCurrent
Issue 02 (2012-05-24)
16
1 Alarm Reference
Name hwEntityTrapFaultID
Meaning Indicates the error code. The error code in this alarm is 618.
Possible Causes
The fan does not work. The ambient temperature exceeds the operating temperature range of the switch.
Procedure
Step 1 Check that the fan works normally. Step 2 Check that the ambient temperature is within the operating temperature range of the switch. ----End
Related Information
None
Attribute
Alarm ID 1.3.6.1.4.1.2011.5.25.219.2.6.5 Alarm Severity Warning Alarm Type equipmentAlarm(13)
Parameters
Name hwEntityPhysicalIndex Meaning Indicates the device index.
Issue 02 (2012-05-24)
17
1 Alarm Reference
Meaning Indicates the device name. Indicates the relationship between the device temperature and the alarm threshold. The value is fallBelow(1), indicating that the device temperature falls below the alarm threshold. Indicates the temperature alarm threshold. Indicates the current temperature. Indicates the error code. The error code in this alarm is 618.
Possible Causes
None
Procedure
None
Related Information
None
Issue 02 (2012-05-24)
18