Beruflich Dokumente
Kultur Dokumente
FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldServer.com Website: www.fieldServer.com Page 1 of 7
Protocol Driver
Connection Information Connection type: Baud Rates: Data Bits: Stop Bits: Parity: Flow Control: Multidrop Capability Devices tested Device Envirotronics Systems Plus Controller Tested (FACTORY, SITE) Factory RS-232 300; 600; 1200; 2400; 4800; 9600; 19200 Baud 7,8 1,2 Odd, Even, None RTS / CTS No
FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldServer.com Website: www.fieldServer.com Page 2 of 7
Protocol Driver
Connection configurations
8917-01 WIRE LIST DB25M FUNCTION RX CTS DSR GND GND DTR RTS TX FROM RJ45-01 RJ45-02 RJ45-03 RJ45-04 RJ45-05 RJ45-06 RJ45-07 RJ45-08 TO COLOUR DB25M-03 WHITE DB25M-05 BROWN YELLOW DB25M-07 GREEN RED BLACK DB25M-04 ORANGE DB25M-02 BLUE
DB9F
8917-02 WIRE LIST FUNCTION FROM Rx RJ45-01 GND RJ45-04 Tx RJ45-08 TO DB9F-03 DB9F-05 DB9F-02 COLOUR WHITE GREEN BLUE
OR
(408)-262-2299
Connection Notes Additional Systems Plus Controllers may be connected each to a separate serial port on the FieldServer. FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldServer.com Website: www.fieldServer.com Page 3 of 7
Protocol Driver
Communications functions - Supported functions at a glance: Data Types Supported FieldServer Data Type Analog Input Binary Input Analog Output Binary Output FieldServer as a Client Read Analog Read Binary Parameter Data: Parameter Status: Read Setpoint Read PV Read Deviation Read Program Read Event Status Read Events Read Remaining Step Time Read Aux Read Auxs Read Remaining Read Start Time Step Cycles Enabled Read Selected Read Stop Time Program Enabled Read Step Number Read Alarm Status Read Step Time Read Alarm Log Read Start Step Read Audible Alarm Read Initial Setpoint Read Start Time Read Stop Time Read Software Version Description (or Device Data Type) Device parameter data Device parameter statuses Device parameter data Device parameter statuses
Set Setpoint Select Program Set Start Step Set Initial Setpoint Set Start Time Set Stop Time Set Date Set Time
Set Event Set Aux Set Circulators Set Lights Set Start Time Enabled Set Stop Time Enabled Set Audible Alarm
FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldServer.com Website: www.fieldServer.com Page 4 of 7
Protocol Driver
FieldServer as a Client System Control System Editing Commands: Commands: Emergency Stop Editing Set Auxs Hold Program Programs: Set Cycles End Edit Resume Program Set Next Edit Program Start Program Read Program Read Units Start System Set Analog Min Edit Step Stop Program Set Analog Max Read Step Stop System Set Analog Type Remove Step Alarm Reset Set Engineering Min Alarm Acknowledge Insert Step Set Engineering Max Add Step Use Keypad Clear Program Set Analog Address Set Units Read Number Steps Read Setpoint Editing Channel Read Gsoak Configuration Enabled Parameters: Edit Analog Read Gsoak Read Duration Read Analog Min Read Analog Max Read Events Read Analog Type Read Aux Read Engineering Min Read Cycles Read Engineering Max Read Next Read Analog Address Set Setpoint Set Gsoak Enabled Set Gsoak Set Duration Set Events Unsupported Functions and Data Types Function Use Emulator Mode
Editing Alarm Configuration Parameters: Edit Alarms Read Scan Set Scan Editing Fuzzy Configuration Parameters: Edit Fuzzy Read Fuzzy Set Fuzzy Fuzzy phrases allowed: Heat Cycle Time Cool Cycle Time Heat Sensitivity Cool Sensitivity Heat Max Power Cool Max Power Heat Min Time Cool Min Time Heat Stage Delay Cool Stage Delay Dead Band
Reason Emulator mode is used for remote user access via the devices system menu and cannot be used against a FieldServer for status monitoring and control.
FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldServer.com Website: www.fieldServer.com Page 5 of 7
Protocol Driver
Functions Described The functions listed are read, write or control type command functions. Read functions request data from the Systems Plus device and store the data in data arrays made accessible to other protocol drivers. Read functions normally run continuously to update data from the Systems Plus device to the FieldServer. Write functions take dynamic or static preloaded data from data arrays and request the Systems Plus device to update the relevant data internally. Data for write may be set up by other protocol drivers or be available as static data. Write functions may be set to write once, continuously or be triggered by other protocol drivers on the FieldServer Control type functions usually do not transfer data but are used to effect system control such as starting and stopping the device. Control functions are normally triggered from other protocol drivers on the FieldServer.
FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldServer.com Website: www.fieldServer.com Page 6 of 7
Protocol Driver
FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldServer.com Website: www.fieldServer.com Page 7 of 7