Price List

lm

Cutler-Hammer

October 1997
Supersedes Price List 32-624
Pages l-1 6, dated April, 1995
Mail to: E/SMML; C/32-000
B

B.

Index
Page
Table
13
Automatic Throw-over ........ 7 .............
9
Breaker Accessories.. ......... 6 ............
4 ............
4
Bus Modifications.. .............
6 ............
7
Busway Risers.. .................
5 ..........
6A
Breakers, Draw-out ............
5 .............
6B
Breakers, Fixed ..................
7 .............
16
Compression Lugs.. ............
--Descnptmn / Application ..... 1 .............
7 .............
17
Documentatmn ...................
6 .........
8.9
Ground Fault ......................
14
High Resistance Ground ...... 7 .............
6 .............
10
IMPACC Devices ...............
2
Incoming Connections ......... 4 ............
7 .............
17
Instruction Books ...............
11
Instrument Transformers ..... 6 .............
10
Instruments and Meters ...... 6 .............
5 ...........
68
Interrupting Ratings ............
7 .............
15
Miscellaneous ....................
1 .............
--Ordering lnformatlon ...........
2 .............
--Pricing Example .................
1 .............
--Pricing Instructions .............
7 .............
12
Relays.. .............................
4 ............
5
Seismic.. ...........................
4 ............
2
Service Entrance ................
8 .............
18
Structure Layouts ...............
4 ............
5
Structure Options ...............
1
4 ............
Structure Pricing ................
14
System Ground Detection ... 7 .............
7 .............
17
Testing.. ............................
6 .............
11
Transducers.. .....................
6 ............
8
Trip Unit / Options .............
4 ............
3
Utility Sections ..................

Description and Application


A Type POW-R-M-S Switchboard is an assembly of metal enclosures, each housing
draw-out or fixed mounted low voltage insulated case circuit breakers. UL Standard 891
and NEMA Standard PB-2 govern the design
and construction of a Type POW-R-M-S Switchboard.
In addition to the drawout version and fixed
mounted version of System POW-R Breakers
(SPBI, the assemblies normally include control and measuring devices such as relays,
instruments, meters, instrument transformers. control
power transformers
and the
necessary power bus work and control wiring
for ac system applications up to 600 volts.
A type POW-R-M-S
Switchboard
is ideally
suited to applications calling for service entrance switchboards, secondary equipment in
coordinated secondary substations and auxiliary control and distribution switchboards by
all types of industrial, commercial and utihty
usars. A POW-R-M-S
Switchboard carries a
proven hlstory of reliable circuit protection

32-624

Page 1

Underwriters Laboratories, inc. labeled


600 Volts AC Maximum
200 kA, RMS Sym. Short Circuit Maximum
800-6000
Amps Continuous

and control, which is readily Integrated with


the PC-based IMPACC remote monitoring
and control package.
Cutler-Hammer offers a complete line of SPB
breakers rated from 400 to 5,000 Amperes.
These breakers come standard with the stateof-the-art true RMS sensing Digitrip trip units to
provide specified tripping characteristics.
For further application data, refer to CutlerHammer Catalog 55-000.
Pricing Instructions
This price list is to be used exclusively for
pricing low voltage, dead front, rear accessable, msulated case circuit breaker assemblies, and only as complete assemblies. The
items in the various tables are listed only for
application to, including with, or modification
of the base-unit also selected and priced from
this pnce hst. It IS not to be used in conjunction with any other price list to arrive at a total
price.
The procedure for pricing from this price list
consists of totaling the following price elements from the price tables in line with the
specified or proposed bill-of-material:
Base Unit IStructure) Price + Device Price +
Modification Price = Total List Price.
Before a POW-R-M-S Switchboard assembly
can be accurately priced, a complete layout
must be made based on layout Information
contained in Table 18. This is necessary to
determine the number of structures to be
priced. Layouts that are not shown in Table
18 are considered nonstandard and will increase the price. Special arrangements of this
type or any items which cannot be priced from
this price list will require that the entire billof-material,
including complete specifications, be referred to Cutler-Hammer for pricing.
All prices derived from this price list are
preliminary until final prices are approved by
Cutler-Hammer. Prices listed are F.O.B. manufacturlng point, with freight charges prepaid
to common carrier nearest to the first destination within continental U.S., or nearest
point of departure for export.
Prices reflected in this document are hst
prices subject to change without notification.
Where the proposed switchboard represents
an extension of existing switchboard manufactured by other than Cutler-Hammer where

Type POW-R-M-S
Low-Voltage
Distribution
Switchboards
mechanical match and line up is required, see
Table 4 for appropriate price addition. When
pricing a mechanmal match and line up to an
existing WestinghouseorCutler-Hammerswitchboard, refer to Cutler-Hammer for pricing.
All quotations from this price list will be par SP
25-000.
Ordering Information
When ordering, provide the following mformation:
1. Single-line diagram showing main connections and a layout sketch showing the
desired order of assembly of individual
sections.
2. Where incoming cables or metal enclosed
bus is to enter (top, rear, end, etc.).
3.

Electrical Service (i.e., 3.phase, 4.wire,


2771480 volts, etc.) and Ampere rating.

4.

Appropriate power company and the drawing reference which applies to this order. If
the factory does not have the appropriate
information, forward it with the order papars.

5. Interrupting and current ratings of each


circuit breaker. Type and rating of trip and
otherattachmentsforeachcircut
breaker.
6.

Manual or electric operation. For electrically operated devices, specify the ac or dc


voltage of the control source. 0

7. Number and size of power cables and


conduits for each circuit and where they
are to enter (top or bottom).
8.

Complete nameplate wording for each circuit identification nameplate.

9. Instrument transformer ratios. Indicate any


special instrument scales unless the manufacturer is to select them.
10

Complete

information

on equipment

fur-

nished by others, but required to be mounted


in, or coordinated with the switchboard.
11

Verification that the switchboard is 10 be


used as service entrance equipment.

12

Maximum length of shipping sectmn,


less than ten feet.

if

a Iftheac controlvoltageisabove 240volts. it will be


necessary
to include and price a control power
transformer.

Price

List

32-624
Page

Type POW-R-M-S

Low-Voltage

Distribution

Switchboards

Pricing Example
ipecification
ldoor secondary low voltage switchboard close coupled to (2) 2000 kVA liquid type power transformers wth 4BOY1277 volt secondary
I a double ended umt substation construction. The switchboard shall be equipped with 12) 3000 Ampere main draw-out, electrically
@rated encased power breakers and 11) 3000 Ampere draw-out electrically operated encased tie breaker. Each breaker shall be equipped
vith selective long and short time delay solid state trip units including 4.wire integral ground fault. A solid state automatic throw-over
theme shall be supplled to transfer all loads to remaimng energized bus section in the event of loss of voltage at the other source. Voltage
detection shall be three phase. Furnish microprocessor based multifunctional main metering devices for each main as shown on the one
ne diagram.
20 Volt Control power shall be integral to the switchboard
ceder breakers shall be drawout as shown on the drawings and shall have long time delay, short time delay. instantaneous and 4.wre
ltegral ground fault solid state true RMS sensing trip units. Interrupting capacity of each breaker shall be 100,000
Amperes. Each feeder
breaker shall have three current transformers, 2% accuracy ammeter and phase selector switch. Lugs for breakers shall be compressnn
vpe.
-he switchgear

Clne-Line

shall be braced to withstand

100,000

AIC symmetrical

Diagram

2000 KVA
LIOUIDFILLED
TRANSFORMER
4801277
3 PH. 4W

4801277
3 PH. 4W

CONTROLPOWERTRANSFER

MAINBREAKER

MAINBREAKER

I(1 DP-4000

IQ DP- 4000

3000A
TIE BREAKER
EO
IOOKAICBRACING
16ooA
MD

BUSRISER

BUS RISER

Price

32-624

List

Page 3

Type POW-R-M-S
Pricing

Example

INSTRUMENT

Switchboards

COMPARTMENT

COMPARTMENT

TRANSITION
TD
2000 KVA
LIQUID-FILLED
TRANSFORMER
4801277
3.PHASE
4 WIRE

3000A
E.O.
(LSG)
DRAWOUT

t-21

1600A
M.O.
(LSIG)
DRAWOUT

800A
M.O.
(LSIG)
DRAWOUT

3000A
E.O.
(LSG)
DRAWOUT

1600A
M.O.
(LSIG)
DRAWOUT

800A
M.O.
(LSIG)
DRAWOUT

t?OOA
M.O.
(LSIG)
W/RISER
DRAWOUT

.........

.........
.........
.........
.........
11.. ....
11.. .......
8 .........
3 .........
2 .........
2 .........
8 .........
8 .........
6
.......
2
3
4
4

12
12
6
1

.........
.........
.........
.........

1 .........
2 .........
2 .........
4 .........
Total

List

800A
M.O.
(LSIG)
W/RISER
DRAWOUT

2, -1

Equipment

TRANSITION
TD
2000 KVA
LIClUID-FILLED
TRANSFORMER
4801277
3PHASE
4WlRE

3000A
E.O.
(LSG)
DRAWOUT

21 +21+21+21+21+

w
5
2

COMPARTMENT

1600A
M.O.
(LSIG)
DRAWOUT

1600A
M.O.
(LSIG)
DRAWOUT

800A
M.O.
(LSIG)
W/RISER
DRAWOUT

INSTRUMENT
BLANK

BLANK

October 1997

Distribution

(continued)

INSTRUMENT

Pricing

Low-Voltage

Unit
List Price

Table

Total
List Price

Base.21W,3000A. 4W.Cu Bus


TransitiontoTransformer,21W,3000A,4WCu
Bus
114 High Blank Cell .................................
InstrumentatlonCompartment
......................
Tie BreakerStructureAdder.3000A
..................
Short Circuit Bracing 100 kA ........................
RisertoBusway.4W.800A..
........................
SPB-100 3000A E.O.Drawout..
........
..........
SPB-100 1600A M.O.Drawout......................
SPB-100 800A M.O.Drawout.......................
Dlgitrip RMS 51OlL. II ..............................

1..
$ 1,465
2..
4.900
5. .......
1,015
5 .........
100
4. ........
790
4 .........
475
7 .......
2.200
64.. .... 41,770
64.. .... 20,600
64.. .... 11,720

8 .........

STLI ........

ShonTimePickupandDelay
.........................
Integral GF Residual Type 4W 2000A ..................
Integral GF Residual Type 4W3000A
..................

8 .........

......

8. ........
8. ........

190
850

Key interlock System Per Lock .......................


IDDP-4000 ........................................
MiniatureACAmmeter2%.
..........................

9 .........
10 .......
10 ........

5,010
240

......

AmmeterSwitch
...................................
ms ..............................................
CurrentTransformer800A
...........................
CurrentTransformer
1600A
......................
CurrenrTransformer3000A
..........................
Main PowerTransfer:MainTieMain.ThreePhase
VoltageDetection
.................................
ControlPowerTransfer
....
........................

10 ........
ll........
11 ........

240
370
280

.......
.......

280
740

.......

ControlPowerTransformer.JkVA
.....................
CompressionLugs,EOOA
............................
CompressionLugs.1600A
..........................
Price

11
11

.......

......
......

13..
13
15
16
16

....

........
........
........
........

$
.. ...
........
........

.......
.......
.....
......
......

.......
850 .......
520 ......

24,135
550
825
240
310

.......
.......
.......
......

7,325
9.800
3;045

300

790
3,325
4,400
125,310
82,400
46,880

STll
2,090
6,800
2,550
1,040
10,020
1,920
1,920
2,220
3,360
3,360
4,440
24,135

........
.......
........
.......

550
1,650

480
1,240

351.350

Price List

32-624

Page 4

Type POW-R-M-S

Low-Voltage

Distribution

Switchboards

Table 1: Base Structures


Mains, Ties & Feeders
Each structure price includes an indoor steel enclosure with silverplated copper horizontal main bus of the ampacity shown. Price
does not include Incoming power connection or utility compartment
section. Refer to Tables 2 and 3 for pricing.
Main Bus
Ampere
Rating

structure
Width
(inches)

1600
2000
2500
3000
4000
4000
5000
5000
6000
6000

21
21
21
21
21
34
21
34
21
34

able 4: Bus Modifications


Per Structure
Tin plated

4W

$ 1,125

.._
$1,190
.,_
1,285
1,350
1,465
1,605
2,140
_.
1.910
2,445
..___
2,175
..__.
2.740

1,190
1.235
1,330
1,430..
1,860
1,630
2,090
1,860
2,340

_.
..__.,....

Tie Breaker Structure Adder @


1600A&8elow............................
ZOOOA...................................
2500/3000A
4000A...................................
5000A.................................
Match & Line Up With Other
(Per ConnectionI.

Table 5: Structure
tructure

List Price
#
Wires

2000&8el0w
2000 & Below
2500/3000
2500/3000
4000..
4000..

Cable

3 w
4 W
3W..
4 W..
3 W..
4W..

G 0)

$1.105..
1,480
1.635.
2,215.
2,265..
2,980..

Busway

ransformer
Transition

a Q

$ 2,230
_.
_.

C 3,155

2.970
2,690..
3,590.
3,395..
4,530..

. .
_.

Pnce

325

475
600
880

Reduced temp. rise (less than 65O C-ANSI and UL Standard) Consult
. . . . . . . . . . . . .._..........
Cutlar1000 Amps per square inch current density
Hammer

Table 2: Incoming Power Source Connection


Each price includes electrical and mechanical details of the power
source connectmn
to the switchboard.
In the case of a busway
connection,
the price includes the switchboard
bus riser to the
entrance
point and the necessary
cutout
in the switchboard
enclosure.
In the case of the transformer
connection
the price
includes the necessary buswork, flexible connectors,
and 21. wide
vertical structure
(if necessary).
Main Bus
Ampere
Rating

List

bus.

Short circuit bracing ratings: (75 kA is standard)


100 kA __......,....._.....,,.............
150kA
.._.........................
200 kA
.._..............

List Price
3w

Modification

copper

3,920
3.890
4,900
4,085
5,150

5000..
6000..
_._.
4W..
3W..
3,730..
2,825..
3.275..
4,245..
5,660..
5.390..
_. 6,050
6,915 I
7.780
6000. _.
4W.
_. 4;425.
_.
7;185..
8,925
UL Service Entrance
All Ratings
$ 416
Includes UL Service Entrance Label, incoming line isolation barriers and
neutral connection to ground bus.

Table 3: Utility Section 8


Each utility section includes a structure
complete
with bus and
internal barriers and CT and PT mounting
provisions.
Doors are
prowded with necessary cutouts for mounting KWHM. The cost for
the &oming
Poxw Connection
needs to be priced from Table 2.
Use the pricmg for Uni-Camp
utility
type unless your utility
company falls in the other utility types shown.

Manufacturers

590
655
790
945
1.170

. .

Equipment
8,460

ODtions

Modification

List Price

4 High Blank Cell ..............................


$ 1,015
lstrumentation
Compartment
.........................
100
inged Instrument
Panel .............................
415
verhead Breaker Lifting Device (Included on Outdoor)
1,515
hermostat,
Fixed Calibration
.........................
160
hermostat.
Differential
..............................
335
umldlstat
..........................................
255
pace Heater On/Off Switch ...
.......................
130
pace Heater Contactor Control (Less Thermostat)
.........
445
eismic Certification
Certificate (Non Nuclear)
............
250
er Structure Adders
Segregation
Barriers Between Vertical Sections ........
355
Hinged Rear Door (34 Inch Wide Maximum) (Inc. on Outdoor). ... 440
3 Point Latch Mechanism
............................
180
ventscreens
......................................
195
CableSupports
....................................
215
Nonmagnetic
Gland Plate ............................
215
Steel Floor Plates ...................................
180
Steel Floor Channels,,
..............................
385
Cable Pull Box - 24 Inch High ........................
740
Drip Shield, Indoor Structure .........................
430
Space Heater, Indoor Structure, (Included on Outdoor)
.?
150
jutdoor
Enclosure,
Walk-in Type
End Sheets and Roof End Trim (Per Assembly)
......
21 Inch Wide Section or Transition
Section ..........
34 Inch Wide Section.
............................
Utility Section 50 Maximum
......................
ConduitHub(PerHub-Maximumof6HubsPerStructure)
.......

5,980
2,780
3,830
4,760
290

%I Add for base structure price from Table 1 11there IS no ma!n breaker
Con Ed
EUSERC
EUSERC

_. 38.

_.

38.
50 ,.....

!c Mechanical lugs are standard

3,330..
3,500..
N/A...

5.150..
6,210..
N/A..

6,950..
6,885..
N/A...

For compression lugs refer t0 Table

8,680
N/A
9,700

16.

@ Buswayconnectionis for top or bormm enrry only. Pnce 1sfor connecting to


Cutler-Hammer Busway only Refer to Cutler-Hammer if connecting to other
m?ifsctrers.

@ Price 1sfor connecting to a Cutler-Hammer sourced transformer only. Refer to


Cutler-Hammer 11connecting to other manufacturers.
% For bmtom cable entry add an additIonal base section from Table 1 for the
required cable pull sectmn.
%I For all double ended substations select the appmprlate pnce for the Ampere rating
of the ma, bus.
(ij Space heaters are located in the cable compartment. bus compartment and the
bottom breaker compartment of each structure. Each space heater IS rated 95
Watts at 125 Volts. Control power for the space heaters is not Included.
October 1997

Price List

32-624

Page 5

Type POW-R-M-S

Low-Voltage

Distribution

Switchboards

Table 6A: Draw-out


Mounted
Circuit Breaker Units
For complete
manual unit, price includes metal-enclosed
compartment
with cover, manually operated
breaker with Digitrip T-510
(L, I) Trip
Unit, a set of primary disconnects,
set of secondary
disconnects
(when necessary),
racking mechanism,
necessary
mechanical
interlocks.
manual push-to-trip
button,
necessary
small wiring and terminal blocks, and mechanical
cable termmals.
A complete
electrically
operated
unit price also includes closing relay, auxiliary switch and shunt trip device. Provision for future breakers includes all of the above less the
removable
breaker element.
Provisions
for future
electrically
operated
breaker
does not include the push-button
or control switch
and
indicating lights. Price for spare removable
unit IS for the breaker only. See Table 5 for pricing of one-quarter
high blank or instrumentation
compartment.
List Prices
Ampere

Breaker

ProvisionsOnly
For Future Breaker

CompleteUnit

Rating

Type

400

SPB50..

b 11.066

BOO

SPE50..

11.055

BOO

M%lllal

Electric

MaIllJal

13,145.

Electric

Manual

Electric
$ 11.190

$ 1.670

5 1.955..

5 8.365

1,670

1.955.

9,386

11,190
11.416

13,145.

_.

spare
RemovableLIne

SPBlOO.

11,720

13,370.

1.670

1,955.

10,050

1200

SPB66..

14.175

16,760.

2,660

3,005

11.525

13,755

1200

SP8 100.

20,600

23,235.

2,660

3,005

17.850

20.230

1600

SPB65..

19,060

22,145.

3,180

3,605.

15,900

18,540

1600

SPBlOO.

20,600

23,235.

3,180

3,605

17,420

19,630

2000

SPB65.

19,935

26,710.

3,705

4.205..

16,230

20.505

_.

2000

SPB 100.

34,410

37,345.

3,706

4,205

30.705

33,140

2500

SPB 100.

38.020

41,770.

6,665

7,235

31,355

34,535

3000

SPB 100

38.020

41,770.

6.665

7.235

31.355

34.535

4000

SPBlOO.

52,160

56,185.

12,740

13,210..

39,420

42.975

NOTE
FORINTERRUPTINGANDSHORTTIME
RATINGS SEE TABLE 68

Table 66: Fixed Mounted


Circuit Breaker Units
For complete
manual unit, price includes metal-enclosed
compartment
with cover, manually operated
breaker with Digitrip T-510
(L. I) Trip
Unit, manual push-to-trip
button,
necessary
small wiring and terminal
blocks,
and mechanical
cable terminals.
A complete
electrically
operated
unit price also includes closing relay. auxiliary switch and shunt trip device. Provision for future breakers includes all of the above
less the removable
breaker element.
Provision for future electrically
operated
breaker does not include the push-button
or control switch
and mdlcating lights. See Table 5 for pricing of one-quarter
high blank or instrumentation
compartment.
List Prices

4mpere

Breaker

Manual

jating

Tvpe

400..

SPB60..

$ 9,016

800

SPB50..

9.016

800

SPBIOO..

9,560

1200

SPB66..

11,610

1200

SPBlOO

17,635

,600

,.

FX,

..,
,..,

,.

Electric

MallUal

_. $

$ 10,685.
_.

10,885..

13.135

._...,

14,205

.._.._

._.
._

1.420

13.580

._.

18,890

_.

2.250

N/A

._.._.

1,686

N/A

.._...

1600

RDC ,..,

,600

SPB 65,

16.436

17,885

1600

SPBlOO.

17,636

19,880.

2000

RD .,..,

14.030

2000

RDC...

15.215

N/A

2000

SPB65.

17.810

20,740

2000

SPBIOO..

29,375

2500

SPBlOO.

3000

_.....

1,420

N,A

Electric

_.

2,250

._.
_.

.._.._

_...,,

_.._,

1,685
1,665

6OOV

42....

25

25..

25

65

50.

42

25

25..

25

100

100..

50..

25

25..

25

85

65..

42.

35

35..

35

2,555

100

100..

50..

35

35..

NIA.

125

65..

N/A...

200

_.

1,660

.._.

480v

100

3,066

85

65.

3,065.

100

N/A...
NIA...

6oov

35

50

N/A

N/A

N/A

65.

N/A

N/A..

N/A

42

35

35.

100..

85..

35

35

125

65

50...

N,A

NIA...

N,A

200

100..

65

N/A

N/A...

N/A

65

42

35

35

35

36

3,575

31,870..

3.150

3,675

_.

100

100..

85.

35

35.

35

32,440

35,630

6,665

6,150

._.

100

100

85

35

35..

35

SPBlOO.

32,440

35,630

4000

SPB100..

44,460

5000

SP8100..

50,300

L Higher short twne ratings are available

October 1997

._.

._.

85

35

3,150

_.

._.

480V

50.....

2,555,.

1,685

2,700

240v

65

1,680

2.700

._. ._

240V

5 1,680..

1,420

11,105

,_.

ShoRTimeRating
lnterruptlng Rating
I
( RMS Symmetrical Amperes (000) %,

ProvisionOnly
For Future Breaker

CompleteUnit

5,665

6,150.

100

100..

85..

35

35..

35

47,885..

10,825

16.885..

100

100..

85..

65

65

65

55,140..

12,890

19,885

100

100..

85..

65

65..

65

Refer to Cutler-Hammer

_.

Price List

32-624

Page 6

Type POW-R-M-S
Table 7: Riser to Busway
Main Bus
Ampere
Rating

Low-Voltage
- Outgoing

Distribution

Feeder

Switchboards

Table 10: Instruments.


cIevices

List Prices
3w

4w

800 ......
$1.660 .....
1600/2000 .. 2.230.
.....
2500/3000 ..
2.690 ......
4000 ......
3.395 ......
5000 ......
4.245 ......

$2,200
2,970
3,590
4.530
5,660

...

....
....

....
....

4w
$2,215

I
....

$1,670
2,240
2,715
3,420
4,265

.....

2,sso

.....
.....
.....

3,615
4,550
5,680

Table 8: Trip Units and options


Trip Unit I Option
Digitrip
Digitrip
Digitrip
Digitrip
Digitrip
Digitrip

List Price

RMS 510 (L.1) Trip Unit (Standard).


..........
RMS 610 (L.1) Trip Unit .. .@.....................
RMS 810 (L.1) Trip Unit .. .%. ..................
RMS 910 (L.1) Trip Unit .. .!?. ..................
OPTIM 750 Trip Unit .... !?. ..................
OPTIM 1050 Trip Unit ... .? ...................

Adjustable
Trip Function
Short Time Pickup and Delay ........................
Zone selective
interlocking
(Digitrip
Only).
Integral

Ground

Table 9: Breaker Attachments


Option

I Accessory

STD
640
2,760
3,445
2,240
3,550

190
655

..........

Fault Pickup / Dela~ZOOOA I3200

Residual Type 3 W ............


Residual Type 4 W ..............
Zone Selective
Interlocking
(Digitrip
Only) ................

(Indicating

Type1 and IMPACC

Equipment

1 Outdoor
1
3w

Indoor

Meters

Aj4000A15000A

$ 415

850

..

4155
415$
415
850 1,070
1,070

655

..

655

655.

655

And Accessories

.............................

List Price

Shunt Trip, Manually


Operated Breaker ..............
Operation
Counter ...................................
Auxiliary
Switch, 4.Pole@. ............................
OPTlMizer .........................................
Bell Alarm Switch, Electric or Manual Reset ...............
Mechanical
Interlock; Two Breakers ...................
Undervoltage
Release, Instantaneous
....................
Undervoltage
Release, Time Delay ....................
Key Interlock System, Per Lock .........................
Lockable Breaker Door Handle ..........................
Spring Release Solenoid
..............................
Manual Close Prevent ..................................
Padlockable Push to Trip Button .........................
Capacitor Trip Device .................................
Trip Unit Test Kit Digitrip ...........................
Digitrip Auxiliary
Power Module
APM ..................
Shuners ............................................
Position Indication & Interlock Switch (TOC) ..............
Zero Sequence Type Ground Fault @
Standard
Selective .............................
Zone Interlocking
..............................
Test Panel ....................................

615
430
445
1,395
610
1,400
645
1,095
520
215
595
65
75
335
9,145
210
355
600
2,930
3,625
1,820

List

IQ Data Digital Metering


(Including
Disconnect
Switch)
IQ DP-4000 Digital Metering and Protection Unit
(Incl. Disc. Switch). .................................
IQ Analyzer with waveform
capture
..................
IQ Analyzer without waveform
capture. ...............
Addressable
Relay II .................................
Assemblies Electronic Monitor II ......................
BIM (Breaker Interface Module) .......................
Product Operated Network Interface (INCOM) ..........
Product Operated Network Interface (RS2321 ............
Product Operated Network Interface (MODEM)
..........
Ac Voltmeter,
1%. ...................................
Ac Ammeter,
1% ....................................
Miniature AC Voltmeter, 2% ...........................
Miniature Ac Ammeter, 2% ...........................
Voltmeter Switch. ...................................
AmmeterSwitch..
..................................
Ac Wattmeter.
.....................................
Varmeter
.........................................
Frequency Meter ...................................
Power Factor Meter ..................................
Synchroscope
With Two Lamps ......................
Temperature
Meter Equipment,
Incl. Test Resistor &
RTD Selector Switch
..............................
Thermal Demand Ammeter,
1 PH ....................
Thermal Demand Ammeter,
3 PH ....................
Test Block .........................................
Test Plug ........................................
Watt-hour
Meter, 2 Element ........................
Watt-hour
Meter, 2 l/2 Element .....................
Watt-hour
Meter, 3 Element ........................
Watt-hour
Meter, Totalizing
.......................
Varhour Meter, 2 Element ..........................
Varhour Meter, 2 l/2 Element .......................
Varhour Meter, 3 Element ..........................
Demand Attachment
................................
Ratchet to Prevent Reverse Rotation ...................
Pulse Initiator
......................................
Elapse Time Meter ..................................
Table

11: Instrument

Transformers

m Requires control power source. Add for c~ntml power transformers from Table
15 if a separate control power swrce IS not wallable.
a Contacts are not field reversible. The number of available contacts 1sIlmlted.
Rewew speclflcatlon requirements with Cutler~Hammer
@ Control power transformer must be added from Table

EATON

15

-I

2,425
5.01~
12,705
11,615
775
2,705
8.27C
1,160
1,160
1,160
300
300
240
240
240
240
1,125
1,125
1,095
945
1,360
4,900
1,560
4,690
710
1,450
3,420
3.760
4,500
10,160
3.420
3.760
4.500
960
195
300
325

List Prices

..............
................

PotentialTransformerwithFuses.
150VAMaximum
PotentialTransformerwlthFuses.500VAMaximum

$ 370
630

CurrentTransformer.Single5AmpSecondary.
Instrument ...
WindoworBarType .............................
Class ......
2000AandBelow ................
.........
5 280 ....
2001 Ato6000A ..............
740 ......
...............
............................

...

............................
CurrentType ................................
FrequencyType ...........................
VoltageType.

a Buswayconnect~on~sforonetoporbottomexitrunonly.
PriceIsforconnecting
to Cutler-Hammer busway only. Refer to Cutler-Hammer If connecting to other
busway manufacturers or if there IS more than one riser per vemcal sewon.

Prices

and Transducers

Equpment

Transducers..

WansorVars-2Element..
WattsorVars-2112Element..
WattsorVars-3Element..

...................
...............
...................

0.1mA

...

5 270 ....
270 ......
1,200 .....
910 .....
1,050 .....
1,270 .....

Relay
Class
t 595
900
4-20 mA
$ 800
800
3,375
1.270
1.340
1.560

@ Does nat include software. computer or field serwce

October 1997

Price List

32-624

Page 7

Type POW-R-M-S
Table
Device

......

......
Table

List Price

FUK!bOf-

50151 ..
51N ...
50 ....
50 ....
50 ....
50 ....
67 ....
67N ...
49150 ..
49150 ..
59 ....
59 ....
27159 ..
47 ....
27/47 ..
81 ....
25 ....
2.62 ..
46 ....
32 ....
87 ....
87 ....
87 ....
87 ....
86 ....

......
......
......

Table

12: Relays

Overcurrent
Phase, Ground ...............
$ 2,030
Overcurrent
Phase, Ground ...............
$ 2,030
Ground Overcurrent, 1 Element .............
3,455
Ground Overcurrent. 1 Element, Zero Seq. ....
3,455
Instantaneous Overcurrent,
2 Element ........
3,185
Instantaneous Overcurrent, 3 Element ........
5,600
Directional Phase Overcurrent (Time Delay) .. 13,900
Directional Ground Overcurrent
.............
5,485
Temperature
with Instantaneous,
1 Element ... 3,450
Temperature
with Instantaneous, 2 Element ... 6,520
Instantaneous Overvoltage,
1 Element ........
3,250
Instantaneous Overvoltage,
3 Element ........
5,175
Voltage - Under/Over
......................
5,485
Undervoltage
and Reverse Phase ............
8,155
Undervoltage,
Reverse Phase, 1 Phase Pmt. ... 8,155
Underfrequency
(Time Delay) ...............
7,225
Synch Check Relay .........................
9,595
Timing Relay ..............................
5,805
Phase Current Unbalance ...................
9,045
Reverse Power, 3 Phase .....................
4,990
Transformer
Differential, 1 Phase ............
5,515
Motor/Generator
Differential
...............
14,445
Transformer
Differential High Speed .........
24,455
3 Phase Differential Instantaneous ...........
5,375
Lockout Relay, Manual Reset ................
1,215
Auxiliary Relay, 4 Pole Fixed Mounted ..........
130
Auxiliary Relay, 2 Pole Drawout ................
445
Auxiliary Relay, 6 Pole Drawout, Self Reset ....
2,930
Auxiliary Relay, 6 Pole Drawout, Electric Reset
3.730
IQ 1000 Motor Protection Relay Package ......
2,945

13: Automatic

Type Throwover

Throwover

Systems

System

Switchboards

Equipment

Equipment

List Price

Control Power Transformer (Including Disconnect Switch, Primar)


& Secondary Fuse)
1 kVA ...................................................................................
$ 655
3 kVA .........................................................................................
825
5 kVA .....................................................................................
1,290
10 kVA ...................................................................................
1,900
Control Power Disconnect Switch (For Remote Control Power) ....... 310
Fuse Block, Pull Out, P-Pole, 600 Volts Maximum .................... 195
Fuse Block, Pull Out, 3-P&,
600 Volts Maximum .................... 240
Breaker Control Switch ................................................................
470
Type W-2 Switch ..........................................................................
580
Standard incandescent lamps. ...................................................
240
Standard LED lamps ....................................................................
330
Push-to-test incandescent
lamps.. ............................................
345
Push-to-test LED lamps ..............................................................
400
Transformer-type
incandescent lamp .......................................
330
Push-to-test transformer type ....................................................
400
Push-button .................................................................................
240
Alarm Horn or Bell ........................................................................
520
Time Switch ..................................................................................
960
Control Wire Markers (Nylon Tie, Flag Type, Standard)
Standard
Control Wire Markers, Sleeve (Per Breaker Compartment1 ...... 300
Control Wire Markers, Heat Shrink (Per Breaker Compartment) ..... 595
Special Paint Color (Standard is ANSI 61 Gra~)~
Per structure ...................................................................
3,475
Lighting Arresters (3) (Distribution Class) ................................
290
Surge Capacitor (3) ......................................................................
600
Mimic Bus, Tape (Per Device) .....................................................
180
Mimic Bus, Painted (Per Device) ................................................
300
Mimic Bus. Plastic Strip (Per Device) .........................................
595
Armored Cable Terminator.. ........................................................
735
Breaker Lifting/Transport Truck .............................................
4,345
Remote Test Cabinet ..................................................................
1,275
lmpactRecorder(PerShippingSplit)
..........................................
1,500
Table

18: Compression

Lugs.
List Price Per Connection

Feeder
24,135
16,255

Control Power Transfer

550

Table 14: Svstem Ground Detection

Ampere

3w
C-H Std.

1Non-Std.

400/800 ._.___.__._.....
5 180
$ 615
1600 .._....._._._._._._......240
1.025
2000/2500 _..._._._..._....300
1.225
3000
495
2,045
4000 ,,.,.._,.._._._._._....1,655 _._._.. 3,970
5000
.._..__._......2,020
4,850
6000
3,520
11,495

I
1

4w
C-H Std.
$

240
310
400
660
2,205
2,700
4,695

1 Non-Std
$

820
1.365
1,630
2,730
6,355
7,780
15.325

List Price

Equipment

Neutral Grounding Resistor 10 Ampere Rating Max.


Ground Detector Lamps Resistance Type W/Test Push-button
Transformer
Type WlTest Push-button
_
Pulsing High Resistance Grounding Systed
Wye Source, Current Sensing
Wye Source, Voltage Sensing _._._._._...............................
Delta Source, Current Sensing
Delta Source, Voltage Sensing
.._._._..............................
Audible Alarm
.._..................................................................
Clamp-On Meter
Meter Relay 2% (Voltage)
.._._._......................................

section

required.

695
1.090
1,530
11,005
12,885
12,470
14,350
810
4,240
2,265

Far exceptions. contact factory.

2 Outdoor encloSureS only. Check factory for avallablllty of pant types.


a Standard dravmg format ISAutoCAD 13 DWG and ISsubject to change. Check
Cutler-Hammer for current dmwng format or for other formats.
October 1997

Optional

$23,120

Main Power Transfer: Main, Tie, Main


3 Phase Voltage Detection
3 Phase Voltage Detection (PLC Logic).

awl~ary

15: Miscellaneous

Distribution

List Price

Main Power Transfer: Two Mains


3 Phase Voltage Detection

a 21

Low-Voltage

Table 17: Testino


Description

and Documentation
List Price

Customer Witness Test (per day) ............................................


$5,710
Certified Test Report-Standard
Tests ......................................
655
Instruction Books (For the Assembly and Breakers Only) ..........................
Standard
(For the Assembly, Breakers and Other Major Components)
15 Copies Maximum .............................................................
430
Each additional 5 Copies .....................................................
145
Approval Drawings .......................................................................
2%
Approval Drawings Iresubmittal) ................................................
3%
Mylar Drawings (Per Order Item) ....................................................
95
Auto-Cad Disks of Drawings (Per Order Item) .. . ..................... 1,790
Special Drawings (Per Order Item) ...........................................
3,815
Quality Assurance Procedure Brochure.. ..................................
6,620

Price List

32-624

Page 8

Type POW-R-M-S
Table

18:

Structure

Layout

Instrument
or Blank
Instrument
or Blank

Main
8OOAmp
16OOAmp
POOOAmp
800Amp
1600ArnP
2000Amp

Aain
8OOAmp
16OOAmp
2000Amp
800Amp
1600Amp
2000Amp
8OOAmp
1600Amp
2OOOAmp

Low-Voltage
Guide

Indoor

SPB Circuit

Breakers

0 @0

Utility

r
4000Amp

8OOAmp
16OOAmp
2000Amp

34

Fig.=

- Fixed or Drawout

-I

--2l

l&

4000Amp

Otherwise

800 Amp
1600AlnP
2000 Amp

800Amp

this

All vertical sections are 92 in. high plus 4 m ventilators. When top-of-gearmounted breaker lifter IS used, height is 104 in.

a Fixed mounted and drawout mounted SPB breakers cannot be mounted in the same
vertical section.
Q Fixed mounted SF8 breakers and fixed mounted Sews C R-frame breakers may
be mounted I the same wrtical section.
0

800 Amp
16OOAmp
2000Amp

1600Amp
2000Amp

-I

0 Maximum mdoor shwping group is five (5) vemcal sectIons lncludmg transition
sections or 120 inches. For outdoor refer to Cutler-Hammer.

(Tie)
800Amp
1600Amp
20OOAmp
0

--I

Series C R-Frame
Circuit
Breakers

Instr%lent

(Tie1

Full
Height
Auxiliary
Section
With
Hinged
Front
Door

Figure 6

--_I

when used.
Ampere.

lstrz%?t

2500Amp
3OOOAmp

Auxiliary/
Transition
Section

8OOAmp
16OOAmp
2OOOAmp

Blank

800 Amp
1600 Amp

Tie)

Compartment

Utility CT
Companment
AddAdjacent
ToMainSection
When Required
Depth Dimension
ame as Main Sectiol

Main

2500Amp
3OOOAmp

800Amp
16OOAmp

800 Amp
1600 Amp
2000 Amp

Sections

Switchboards

Instrument
or Blank

Main

FeederBand
Tie Sections -(Tie) position
position can be used as feeder of same

(Tie)
8OOAmp
1M)OAmp
2OOOAmp

Main

Instrument
or Blank

il+

Distribution

For 5000A appltcatlons. Refer to factory.

0 When bus ducts out of feeder sections are specified. the depth of the secondary
lmeup will increase and the stacklng maybe affected. Refer to Cutler-Hammer.

NOTE: Dimensions are in inches Imillimeters)

Cutler-Hammer
221 HeywoodRoad
Arden,North Carolina, USA 28704
Prlnted in USA

October 1997