Sie sind auf Seite 1von 31

GE Power & Water Water & Process Technologies

Analytical Instruments

Sievers Certified Reference Materials and Consumables Catalog

imagination at

work

imagination at work

www.geinstruments.com

Sievers Certified Reference Materials and Consumables


For more than 20 years, thousands of customers worldwide have relied on Sievers* Total Organic Carbon (TOC) Analyzers, Certified Reference Materials (Sievers Standards), and Consumables for their critical TOC measurement needs. GE Analytical Instruments, the recognized world leader in designing and manufacturing TOC measurement technology, combines this expertise with the renowned Six Sigma methodology to ensure the finest quality in its standards and consumables. Sievers Standards and Consumables provide unmatched performance and reliability in the marketplace. Sievers ready-to-use Standards are designed for calibration, validation, system suitability, and compendial test applications, and can be used with most other TOC analyzer brands. We also offer Certified (<10 ppb) TOC Vials, TOC Sample Vials for process monitoring, consumables, and replacement parts for Sievers TOC Analyzers.

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES

Contents
About Sievers Certified Reference Materials and Consumables Sievers Standards Benefits Sievers Standards Products and Applications How To Order Sievers Certified Reference Materials and Reagents Sievers Certified Reference Materials Sievers 900 Series TOC Analyzer Standards Sievers 500 RL Series TOC Analyzer Standards Sievers 5310 C Series TOC Analyzer Standards CheckPoint TOC Sensor Standards Sievers InnovOx Series TOC Analyzer Standards Standards for Other TOC Analyzer Brands Custom Standards TOC Sample Vials, Containers, and Cleaning Validation Kits Sample Vials, Containers, Cleaning Validation Kits Consumables, Reagents, and Replacement Parts Sievers 900 Series TOC Analyzers Sievers 5310 C Series TOC Analyzers Sievers 500 RL Series TOC Analyzers Sievers InnovOx Series TOC Analyzers CheckPoint TOC Sensor Index of Products Sievers Certified Reference Materials and Reagents TOC Sample Vials, Containers, and Cleaning Validation Kits Consumables, Reagents, and Replacement Parts How To Order 26 27 28 29 24 24 24 25 25 21 9 10 13 16 18 19 20 20 3 5 8

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

Sievers Standards Benefits


Certified and Traceable
With extensive expertise in supporting the pharmaceutical market, GE Analytical Instruments understands how critical compliance and traceability are when using analytical standards. Documentation for our certified and traceable reference materials is important in supporting your data and building confidence in your measurement results. To provide a base for your internal documentation needs, we supply a Certificate of Analysis with each standard that documents source material traceability, the accuracy of the solution, and the statistical uncertainty of measurement associated with production. To provide our customers with the highest level of confidence and the traceability they need, Sievers Standards are prepared from the highest purity raw materials available. Source materials for system suitability standards are traceable to the United States Pharmacopeial Convention (USP). Materials for Japanese Pharmacopoeia testing comply with the required specifications for purity. Other standards for calibration and validation are traceable to National Institute of Standards and Technology (NIST) Reference Materials. In addition, laboratory equipment and glassware are traceable to NIST.

Stringent Quality Control


GE Analytical Instruments makes continuous advancements in the materials science, contamination control procedures, automated processes, and clean room conditions required to produce sensitive, low-level reference materials and consumables. GE Analytical Instruments: Prepares Sievers Standards in accordance with USP Chapter <643>, USP Chapter <645>, EP Method <2.2.44>, and JP Method <2.59>. Incorporates the world-class Six Sigma methodology in an ISO 9001 environment with our manufacturing processes, while applying additional guidelines from ISO 17025 specific to reference material production. Produces Sievers Reference Materials in a class 100,000 clean room to minimize contamination. This standards manufacturing process is unique to the market. Uses only the highest grade raw materials (USP and NIST) available which have undergone rigorous quality control. Limits human error by using advanced, custom-designed, automated manufacturing throughout production.

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES | BENEFITS

Value and Convenience


The Sievers Standards Production Lab (see page 7) not only allows GE Analytical Instruments to maintain the most rigorous TOC standards manufacturing process in the industry, but also enables us to produce standards on a large scale. As a result, our customers benefit from significant cost savings. Moreover, Sievers Standards are designed to maximize productivity when used with Sievers TOC Analyzers. With no preparation required and an extended shelf life, these ready-to-use materials are available when you need them. With the convenience of overnight delivery and confidence that comes with GE Analytical Instruments guaranteed performance, Sievers Standards and Consumables are the logical choice for your business.

Flexible Ordering and Delivery


For your convenience, GE Analytical Instruments offers several programs and ordering methods to fit your needs. The Annual Blanket Standards Order allows you to minimize paperwork and delivery scheduling and save money. With a single purchase order, you can schedule a full year of standards shipments and rest assured they will arrive when needed. North American customers can also take advantage of our on-line store to conveniently order standards 24/7. (See page 8 for details on ordering.)

Why risk the performance of your critical instrumentation and the quality of measurement when you can rely on Sievers Standards?
Guaranteed Consumables and Replacement Parts GE Analytical Instruments provides consumables, reagents, and replacement parts that are certified and designed specific to our instrumentation. As the Original Equipment Manufacturer we provide warranty options and guarantees on consumables, reagents, and parts quality.

Sievers Standards for all TOC Instruments


The Sievers Standards product line is designed for all Sievers TOC instruments, as well as other instrument brands, including Shimadzu, OI Analytical, Skalar, and Teledyne-Tekmar. Custom standards are also available on request. (See page 20 for additional information.).

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

Sievers Standards Products and Applications


System Suitability and Compendial Test Standards GE Analytical Instruments can help you design a system suitability test program that meets your internal needs and satisfies compendial requirements.
System suitability sets are prepared in accordance with USP Chapter <643> and include 500-ppb 1,4-benzoquinone and sucrose solutions along with the associated reagent water blank. Sets are available for the Sievers 900, 500 RL, CheckPoint, 800, 2244, and 400 Series TOC instruments. System suitability standards are also available for use with other manufacturers TOC instruments. These standards allow users to comply not only with USP Chapter <643>, but also with European Pharmacopoeia (EP) <2.2.44>, Chinese Pharmacopoeia (ChP) Appendix VIII R, and Indian Pharmacopoeia (IP) <2.59>. The Japanese Pharmacopoeia requires the use of SDBS (Sodium Dodecyl Benzene Sulfonate) as the challenge of the TOC method. GE Analytical Instruments is the first company to offer reference materials to support the new Japanese Pharmacopoeia TOC requirements.

Only GE Analytical Instruments offers a complete TOC validation standard set in alignment with ICH Q2 (R1) guidance.

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES | PRODUCTS AND APPLICATIONS

Calibration and Verification Standards Sets


The purpose of instrument calibration is to minimize bias. Proper calibration is the critical first step to good instrument performance. Sievers Certified Reference Materials will ensure the optimal calibration of your TOC analyzer per GE Analytical Instruments recommendations. GE Analytical Instruments offers a full line of TOC and conductivity calibration standards for a variety of instruments and applications. For on-line instruments designed exclusively for high-purity water applications, specially-prepared Sievers Conductivity Standards are available. For laboratory instruments, such as the Sievers 800, 900, and 5310 C Series, Sievers Calibration Sets include both inorganic carbon and total carbon standards.

Verification Standards Sets


Verification standard sets are typically run if a change is made to the instrument or after maintenance. Calibration curve verification should be conducted on a regular basis with one or more standards within the linear range. GE Analytical Instruments offers a host of verification standards at concentrations across the operating range to demonstrate the accuracy and precision of the measurement system.

Validation Standards Sets


Validation standards are reference materials used for analytical instrument qualification. They help assure that the measurement system meets specifications and that it is suitable for its intended purpose. Validation is a critical component of a quality management system, cGMPs, and regulatory compliance. The Sievers Validation Standards Sets comprehensively address LOD, LOQ, linearity, precision, accuracy, specificity, and robustness as detailed in Sievers validation documentation. Each standards set is specifically designed for the individual instrument and its application.

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

Lab Equipment
3-Step Water System

C E 5 B A

A Pretreatment B Primary Purification C Proprietary Polishing

4 6 H F

D 2 1

3 Production Facility Floor Plan 1 - Stock Room 2 - Glassware Cleaning Room 3 - Pressurized Airlock 4 - Main Cleanroom Area 5 - Weighing Room 6 - Product Transfer Room D Automated Glassware Cleaning E Weighing Equipment F Automatic Vial Fillers G Vial Filling Station H Air-lock Pass-through Windows

Sievers Standards Production Lab


Committed to the highest quality, GE Analytical Instruments manufactures Sievers Standards in a stringent cleanroom environment designed to Class 100,000 specifications and using ISO 9001 and 17025 guidelines. Cleanroom and manufacturing processes have been designed to minimize contamination risks at each step in the production of the standards, using rigorous contamination control protocols, proprietary glassware cleaning methods, and custom-designed automated equipment.

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES | HOW TO ORDER

How To Order
The Americas
Tel: +1 800 255 6964 or +1 303 444 2009 Fax: +1 303 527 1797 Email: Send purchase orders to orders@geinstruments.com Email: Send general inquiries to geai@ge.com Web Store: http://www.geinstruments.com/store Office Hours: Monday through Friday, 10:00 am - 7:00 pm (EST)

Europe, Middle East and Africa


U.K. (European Headquarters) Tel: +44 (0) 161 864 6800 Fax: +44 (0) 161 864 6829 Email: geai.europe@ge.com Austria Tel: +0800 296133 Fax: +0800 296722 France Tel: +0800 90 53 64 Numro vert Fax: +44 161 864 68 29 Germany Tel: +0800 186 2054 Fax: +0800 182 2248 Ireland Tel: +1 800 812734 or 353 876461756 Fax: +44 161 864 6829 or 353 15241651

What to Expect from Sievers Standards and Consumables


Premium performance and accuracy Certified, traceable, and guaranteed Convenient and available whenever you need them (next-day delivery for most shipments) Savings in time, effort, operating budget, and avoidance of costly failures with these ready-to-use products

Asia Pacific
All Countries geai.asia@ge.com China Tel: +(8621) 38777735 Fax: +(8621) 387774695 Email: geai.china@ge.com India Tel: +91 900 434 3626 Email: geai.india@ge.com Japan Email: geai.japan@ge.com

Credit Cards
We accept Visa, MasterCard, and American Express.

Rapid Shipping
Same day shipping is available for most products in North America and Europe. GE Analytical Instruments can deliver your product throughout the world from one of our standards and consumables manufacturing facilities in the US, UK, China, and India.

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

Sievers Certified Reference Materials


The 900 Series Analyzers offer unsurpassed ease of use, analytical performance, versatility, and reliability, and are designed to meet diverse application needs and regulatory requirements. The 900 Series is available in three modelsthe 900 Laboratory, the 900 On-Line, and the 900 Portable. This sections lists the most commonly ordered standards for the 900 Series. See pages 2627 for a comprehensive list of Sievers Standards.

We run two shifts in the QC laboratory to support the production of a multi-million dollar drug. We cant afford any mistakes with system suitability testing because it would slow down production. Thats why we use Sievers Standards. - Analytical Chemistry Manager, API Manufacturer

Sievers 900 On-Line TOC Analyzer Sievers 900 Laboratory TOC Analyzer GE Autosampler

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS | SIEVERS 900 SERIES

Sievers 900 Series


How often should I Conduct a System Suitability Test?
The frequency of system suitability testing is at the users discretion, and really depends on the level of risk the user is willing to accept. Some users do a System Suitability Test before and after each batch, and some do weekly or monthly checks depending on their risk assessment. GE Analytical Instruments can help you design a test program that meets your internal needs and satisfies compendial requirements.

System Suitability and Compendial Standards


The United States Pharmacopeia (USP) Chapter <643>, European Pharmacopoeia (Ph. Eur.) Method <2.2.44>, Chinese Pharmacopoeia Appendix VIII R, and Indian Pharmacopoeia <2.4.30> require the analysis of sucrose and benzoquinone to demonstrate system suitability for TOC analysis. The Japanese Pharmacopoeia requires the use of SDBS (Sodium Dodecyl Benzene Sulfonate) as the test compound. GE Analytical Instruments offers certified reference materials to meet these test needs. Following are the most frequently used standards. For a full list, see pages 2627. When ordering kits, please use the applicable part number and quantity.

System Suitability (40-mL vials) GE Analytical Instruments is the first company to offer reference materials to support the Japanese Pharmacopoeia TOC requirements.
Part # STD KIT8D Description Annual Pharmaceutical Standards Kit for Daily Testing
260 x CSTD 31004-01 (System Suitability Set) 10 sets shipped every two weeks. System Suitability Set includes: (1) Reagent Water Control (Rw), (1) Standard Solution (Rs), and (1) System Suitability Solution (Rss).

STD KIT8W

Annual Pharmaceutical Standards Kit for Weekly Testing


52 x CSTD 31004-01 (System Suitability Set) Two sets shipped every two weeks. System Suitability Set includes: (1) Reagent Water Control (Rw), (1) Standard Solution (Rs), and (1) System Suitability Solution (Rss).

CSTD 31004-01

System Suitability Set


Set includes three vials: (1) Rw - Reagent Water Control, (1) Rs 500 g C/L as USP Sucrose, and (1) Rss 500 g C/L as USP 1,4 benzoquinone.

Japanese Pharmacopoeia (JP) Testing (40-mL vials)


Part # CSTD 90039-01 Description JP Protocol Standard Set
Standard set to meet new Japanese Pharmacopoeia requirements for TOC analysis. This standard set contains: (2) 40-mL glass vial standards, (1) Reagent water, and (1) 500 g C/L as SDBS standard.

Sievers 900 Portable TOC Analyzer

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

10

Sievers 900 Series (continued)


TOC Calibration Sets
Multi-point Calibration Set (40-mL vials)
Part # CSTD 90000-01 Description 900 Multi-point Calibration Standards Set, 40-mL vials
Set includes: (1) Calibration Blank, (5) TOC Calibration Standards (1, 5, 10, 25, 50 mg C/L TOC as KHP), and (5) IC Calibration Standards (1, 5, 10, 25, 50 mg C/L IC as Na2CO3).

Single-point Calibration Standards Sets (40-mL vials)


Part # CSTD 90001-01 Description
Set includes: (1) Calibration Blank, (1) 1 mg C/L TOC Calibration Standard (as KHP), and (1) 1-mg C/L IC Standard (as Na2CO3).

900 Single-point Calibration Standards Set, 1-mg/L

CSTD 90016-01

900 Single-point Calibration and Verification Set, 1-mg/L


Set includes: (1) TOC Calibration Set at 1 mg C/L and (1) Verification Standards Set at 1 mg C/L. Calibration set includes: (1) Calibration Blank, (1) 1-mg C/L TOC Calibration Standard (as KHP), and (1) 1-mg C/L IC Standard (as Na2CO3). Verification set includes: (1) Verification Blank, (1) 1-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 1-mg C/L IC standard (as Na2CO3).

CSTD 90017-01

900 Single-point Calibration and Verification Set, 5-mg/L


Set includes: (1) TOC Calibration Set at 5 mg C/L and (1) Verification Standards Set at 5 mg C/L. Calibration set includes: (1) Calibration Blank, (1) 5-mg C/L TOC Calibration Standard (as KHP), and (1) 5-mg C/L IC Standard (as Na2CO3). Verification set includes: (1) Verification Blank, (1) 5-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 5-mg C/L IC standard (as Na2CO3).

CSTD 90026-01

900 1-mg/L Single-point Calibration and 500-g/L Verification Set


Set includes: (1) TOC Calibration Set at 1 mg C/L and (1) Verification Standards Set at 500 g C/L. Calibration set includes: (1) Calibration Blank, (1) 1-mg C/L TOC Calibration Standard (as KHP), and (1) 1-mg C/L IC Standard (as Na2CO3). Verification set includes: (1) Verification Blank, (1) 500-g C/L TOC Verification Standard (as NIST sucrose), and (1) 500-g C/L IC standard (as Na2CO3).

CSTD 90028

900 Autoreagents Calibration and Verification Set


Set includes: Autoreagents Calibration and Verification Standards Set for the Sievers 900 Series. Calibration includes: (1) TOC Calibration Blank, (1) 25-mg C/L TOC Calibration Standard (as KHP), (1) 25-mg C/L IC Calibration Standard (as Na2CO3), and (1) 50-mg C/L TOC Challenge Standard (as Nicotinamide). Verification includes: (1) TOC Verification Blank, (1) 25-mg C/L TOC Verification Standard (as NIST sucrose), (1) 50-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 50-mg C/L IC Verification Standard (as Na2CO3).

Turbo Standards
Calibration Turbo Standards Sets (250-mL bottles)
Part # CSTD 90021-01 Description 900 Turbo Calibration and Verification Set
Set includes: (1) Turbo Calibration Set at 4 mg/L C and (1) Verification Standards Set at 4 mg C/L. Calibration set includes: (1) 4-mg C/L TOC Calibration Standard (as KHP), and (1) 4-mg C/L IC Standard (as Na2CO3). Verification set includes: (1) 4-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 4-mg C/L IC standard (as Na2CO3).

11

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS | SIEVERS 900 SERIES

TOC Verification Sets


Verification Standards (40-mL vials)
Part # CSTD 90007-01 Description 900 Single-point Verification Set, 500 g/L
Set includes: (1) Verification Blank, (1) 500-g C/L TOC Verification Standard (as NIST Sucrose), and (1) 500-g C/L IC Standard (as Na2CO3).

CSTD 90008-01

900 Single-point Verification Set, 1 mg/L


Set includes: (1) Verification Blank, (1) 1-mg C/L TOC Verification Standard (as NIST Sucrose) and (1) 1-mg C/L IC Standard (as Na2CO3).

TOC Validation Sets


Validation Standards (40-mL vials)
Part # CSTD 31013-01 Description Accuracy/Precision Set
Set includes: (1) Reagent Water Control and (1) 500 g C as NIST Sucrose standard solution.

CSTD 90022-01

900 Validation Set Only


Set includes: (2) System Suitability Sets, (1) Linearity Set, (1) Precision and Accuracy Set, (1) Robustness Set, and (1) Specificity Set. (Note: Calibration and Verification sets must be ordered separately.)

CSTD 90025

900 Validation Set with Calibration and Verification


Set includes: (2) Single-point Calibration Sets at (1) 1 mg C/L, (1) Single-point Verification Set at 500 g C/L, (2) System Suitability Sets, (1) Linearity Set, (1) Accuracy and Precision Set, (1) Robustness Set, and (1) Specificity Set.

CSTD 31012-01

Linearity Standards Set


Set includes: (1) Reagent Water Blank and (1) each 250 g C/L, 500 g C/L, 750 g C/L as USP Sucrose.

CSTD 74409-01

Specificity Standards Set


Set includes: (1) Reagent Water Blank, (1) 500 g C/L as Methanol, (1) 500 g C/L as Nicotinamide, and (1) 500 g C/L as KHP.

CSTD 90037-01

Robustness Standards Set


Set includes: (1) Reagent Water BlankRw, (1) Standard Solution - Rs (500 g C/L as USP Sucrose), and (1) System Suitability Solution - Rss (500 g C/L as USP 1,4-Benzoquinone). Rw, Rs, and Rss standards are acidified.

Certified TOC Sample Vials are also available for Sievers and other instruments. See page 27 for more information.

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

12

Sievers 500 RL Series


The Sievers 500 RL On-Line Total Organic Carbon (TOC) Analyzer is a reagentless analyzer designed to continuously monitor organics in ultrapure water for pharmaceutical, microelectronics, power, and semiconductor applications. The 500 RL with Super iOS model offers standards unique to the Sievers product line. Our patented and convenient Super iOS vial set cartridges are pre-loaded with Sievers Standards and configured for a variety of protocols, including system suitability. The Super iOS automatically sequences through the various vials for a protocol unattended. The Sievers Super iOS enables the confidence and reliability of lab-based system suitability testing in an on-line analyzer.

Super Convenient Integrated Super iOS


With a Super iOS you plug in the combined standards pack, start your protocol, and walk away. Running the standards procedure has been completely automated.

Following are the most frequently used standards for the 500 RL Series. For the full list of standards, see pages 2627. When ordering kits, please use the applicable part number and quantity.

Standards for the 500 RL with Super iOS


System Suitability and Compendial Standards (40-mL vials)
Part # STD KIT5MS Description Annual Pharmaceutical Standards Kit for Monthly Testing Sievers 500 RL with Super iOS
12 x CSTD 74503 (System Suitability Set) Shipped one per month. System Suitability Set includes: (1) Reagent Water Control (Rw), (1) Standard Solution (Rs), and (1) System Suitability Solution (Rss). These standards are packaged in a vial cartridge for use with the Sievers Super iOS System.

Blanket Order Option


In addition to a full range of individual standard sets, we offer annual blanket orders at a discount that you can customize to meet your specific needs and have shipped at your desired intervals.

CSTD 74503

500 RL System Suitability SetSuper iOS


Set Includes: (1) Reagent Water Blank - Rw, (1) Standard Solution - Rs (500 g C/L as USP Sucrose), (1) Standard Solution - Rss (500 g C/L as USP 1,4-Benzoquinone), and (1) Rinse Water Standard. Super iOS standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

Japanese Pharmacopoeia Testing (30-mL vials)


Part # CSTD 74529-01 Description 500 RL with Super iOS JP Protocol Set (TOC)
Standard set for the Sievers 500 RL TOC Analyzer with Super iOS that meets the new Japanese Pharmacopoeia TOC requirements. Set includes: (2) 30-mL plastic vial standards: (1) reagent water blank and (1) 500-g C/L as SDBS standard. The set also includes (1) empty glass vial for alignment. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

13

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS | SIEVERS 500 SERIES

TOC and Conductivity Calibration Sets


Multi-point Calibration Set (40-mL vials)
Part # CSTD 74514 Description 500 RL with Super iOS Multi-point Calibration Set
Multi-point Calibration Set A and B for the Sievers 500 RL TOC Analyzer with Super iOS. Includes: (3) Calibration Blanks, (3) TOC Calibration Standards (500 g C/L, 1.0 mg C/L, 1.5 mg C/L as KHP) and (1) 25-S/cm Conductivity Standard (as HCl). These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

Single Point Calibration Set (40-mL vials and 30-mL vials)


Part # CSTD 74501 Description 500 RL with Super iOS Single-point Calibration Set
Single-point Calibration Set A for the Sievers 500 RL TOC Analyzer with Super iOS. Includes: (2) Calibration Blanks, (1) 1.5-mg C/L TOC Calibration Standard (as KHP), and (1) 25-S/cm Conductivity Standard (as HCl). These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

CSTD 30030-01

Conductivity Standard
Conductivity Standard for the Sievers 500 RL and CheckPoint Series. This standard consists of (1) 25 S/cm as HCl solution in a 30-mL plastic vial.

CSTD 74512

500 RL with Super iOS Single-point Calibration and Verification Set


Single-point Calibration Set A and Verification Standards Set for the Sievers 500 RL TOC Analyzer with Super iOS. Includes: (1) Single-point Calibration Set and (1) Accuracy, Precision, and Verification Set. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

Accuracy, Precision, and Verification Sets (40-mL Vials)


Part # CSTD 74502 Description 500 RL with Super iOS Accuracy, Precision and Verification Set
Accuracy, Precision and Verification Set for the Sievers 500 RL TOC Analyzer with Super iOS. Includes: (1) Verification Blank, (1) 500-g C/L TOC Verification Standard (as NIST Sucrose), and (1) 25-S/cm Conductivity Standard (as HCl). These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

CSTD 74507

500 RL with Super iOS Accuracy, Precision, and Verification Set (TOC Only)
Accuracy, Precision, and Verification Set for the Sievers 500 RL TOC Analyzer with Super iOS. Includes: (1) Verification Blank and (1) 500-g C/L TOC Verification Standard (as NIST Sucrose) packaged in a vial set cartridge for use with the Sievers Super iOS System. Not compatible with 500 RL instruments equipped with the conductivity option.

Validation Sets (40-mL Vials)


Part # CSTD 74513 Description 500 RL with Super iOS Single-point Validation Set
Validation Standards Set with Single-point Calibration Set A for the Sievers 500 RL TOC Analyzer with Super iOS. Includes: (1) Single-point Calibration Set, (2) Accuracy, Precision, and Verification Sets, (1) System Suitability Set, (1) Linearity Set, (1) Robustness Set, and (1) Specificity Set. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

14

Sievers 500 RL Series (continued)


Validation Sets (continued)
Part # CSTD 74515 Description 500 RL with Super iOS Multi-point Validation Set
Validation Standards Set with Multi-point Calibration Set A and B for the Sievers 500 RL TOC Analyzer with Super iOS. Includes: (1) Multi-point Calibration Set, (2) Accuracy, Precision, and Verification Sets, (1) System Suitability Set, (1) Linearity Set, (1) Robustness Set, and (1) Specificity Set. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

CSTD 74506

500 RL with Super iOS Linearity Set


Linearity Set for the Sievers 500 RL TOC Analyzers with Super iOS. Includes: (1) Reagent Water Blank and (1) each 250 g C/L, 500 g C/L, and 750 g C/L as KHP. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

CSTD 74509-01

500 RL with Super iOS Specificity Set


Specificity Set for the Sievers 500 RL TOC Analyzers with Super iOS. Includes: (1) Reagent Water Blank, (1) 500 g C/L as Methanol, (1) 500 g C/L as Nicotinamide, and (1) 500 g C/L as KHP. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

CSTD 74508-01

500 RL with Super iOS Robustness Set


Robustness Standard Set for the Sievers 500 RL TOC Analyzer with Super iOS. Includes: (1) Reagent Water Blank - Rw, (1) Standard Solution - Rs (500 g C/L as USP Sucrose), (1) System Suitability Solution - Rss (500 g C/L as USP 1,4 Benzoquinone), and (1) Flush Standard. Rw, Rs, and Rss standards are non-acidified and are packaged in 30-mL HDPE vials. The Flush Standard is non-acidified and packaged in a 40-mL glass vial. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.

Standards for the 500 RL with Standard iOS


Part # CSTD 74403 STD KIT5M CSTD 74429-01 CSTD 74614 CSTD 74401 CSTD 74612 CSTD 74402 CSTD 74613 CSTD 74615 CSTD 74406 CSTD 74409 CSTD 74408-01 Description 500 RL System Suitability Set Standard iOS Annual Pharmaceutical Standards Kit for Monthly Testing Standard iOS 500 RL JP Protocol Standard Set Standard iOS 500 RL Multi-point Calibration Set Standard iOS 500 RL Single-point Calibration Set A Standard iOS 500 RL Single-point Calibration and Verification Set Standard iOS 500 RL Accuracy, Precision, and Verification Set Standard iOS 500 RL Single-point Validation Set Standard iOS 500 RL Multi-point Validation Set Standard iOS 500 RL Linearity Set Standard iOS 500 RL/900 Specificity Set Standard iOS 500 RL Robustness Set Standard iOS

15

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS | SIEVERS 5310 C SERIES

Sievers 5310 C Series


GE Analytical Instruments offers 40-mL sample vials suitable for environmental and drinking water monitoring at competitive market pricing.
The Sievers 5310 C Laboratory, Portable, and On-Line TOC Analyzers were designed specifically for the municipal drinking water market for continuous monitoring of raw, finished, and plant process waters. The 5310 C has an analytical range of 4 parts-per-billion (ppb) to 50 parts-per-million (ppm) and uses SM 5310 C for USEPA compliance monitoring of raw and finished drinking water. The 5310 C provides unsurpassed ease of use, industry-best analytical performance, and a low cost of ownership for water quality analysis.

Sievers 5310 C On-Line, Portable, and Laboratory TOC Analyzers

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

16

Sievers 5310 C Series (continued)


Following are the most frequently used standards for the 5310 C Series. For the full list of standards, see pages 2627. When ordering kits, please use the applicable part number and quantity.

TOC Calibration Sets (40-mL vials)


Part # CSTD 90001-01 Description
Set includes: (1) Calibration Blank, (1) 1-mg C/L TOC Calibration Standard (as KHP), and (1) 1-mg C/L IC Standard (as Na2CO3).

900 Single-point Calibration Standards Set 1 mg/L

CSTD 90003-01

Single-point Calibration Standards Set 10 mg/L


Set Includes: (1) Calibration Blank, (1) 10-mg C/L TOC Calibration Standard (as KHP), and (1) 10-mg C/L IC Standard (as Na2CO3).

CSTD 96000-01

Multi-point Calibration Set


Set Includes: (1) Calibration Blank, (5) TOC Calibration Standards (250 g C/L, 1, 5, 25, 50 mg C/L TOC as KHP), and (5) IC Calibration Standards (1, 5, 10, 25, 50 mg C/L IC as Na2CO3).

CSTD 90028

Autoreagents Calibration and Verification Set


Set includes: Autoreagents Calibration and Verification Standards Set. Calibration includes (1) TOC Calibration Blank, (1) 25-mg C/L TOC Calibration Standard (as KHP), (1) 25-mg C/L IC Calibration Standard (as Na2CO3), and (1) 50-mg C/L TOC Challenge Standard (as Nicotinamide). Verification includes: (1) TOC Verification Blank, (1) 25-mg C/L TOC Verification Standard (as NIST sucrose), (1) 50-mg C/L TOC Verification Standard (as NIST sucrose), and (1) 50-mg C/L IC Verification Standard (as Na2CO3).

Verification Standards Set (40-mL vials)


Part # CSTD 90031 Description Municipal TOC Verification Set
Municipal TOC Standards Set for the Sievers 5310 C Analyzers equipped with firmware versions 1.40 or greater. Set Includes: (1) 1-mg C/L, (1) 5-mg C/L and (1) 10-mg C/L as KHP standard.

CSTD 90011-01

Single-point Verification Set 10 mg/L


Includes: (1) Verification Blank, (1) 10-mg C/L TOC Verification Standard (as NIST Sucrose), and (1) 10-mg C/L IC Standard (as Na2CO3).

CSTD 90009-01

Single-point Verification Set 2 mg/L


Includes: (1) Verification Blank, (1) 2-mg C/L TOC Verification Standard (as NIST Sucrose), and (1) 2-mg C/L IC Standard (as Na2CO3).

17

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS | CHECKPOINT ON-LINE / PORTABLE

CheckPoint Pharma and CheckPointe On-Line/Portable TOC Sensors


The affordable CheckPoint Pharma and CheckPointe On-Line/Portable Total Organic Carbon (TOC) Sensors provide unsurpassed flexibility in measuring low-level total organic carbon (TOC) online for microelectronics, pharmaceutical, and power applications. They can be used online for continuous monitoring or hand-carried to any point in a water system for rapid diagnostic sampling and troubleshooting. CheckPoint/CheckPointe is the first and only battery-powered TOC measuring device. Following are the most frequently used standards for the CheckPoint. For the full list of standards, see pages 2627. When ordering, please use the applicable part number and quantity.

CheckPoint Portable/On-Line TOC Sensor

System Suitability Standards (30-mL plastic vials)


Part # CSTD 31003-01 Description System Suitability Set
Set includes: (1) RwReagent Water Control, (1) RsStandard Solution and (1) RssSystem Suitability Solution.

TOC and Conductivity Calibration Standards (30-mL plastic vials)


Part # CSTD 97010-01 Description TOC Calibration Set
Set includes: (2) Calibration Blanks and (1) 500 g C/L as NIST sucrose.

CSTD 30030-01

Conductivity Standard
Set includes: Conductivity Standard for the Sievers 500 RL and CheckPoint Series. This standard consists of a 25-S/cm as HCl solution in a 30-mL plastic vial.

Performance Qualification Standards (30-mL plastic vials)


Part # CSTD 97006-01 Description TOC Linearity Set
Set includes: (1) Linearity Blank and (1) each of 250 g C/L, 375 g C/L, and 500 g C/L as NIST sucrose.

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

18

InnovOx Laboratory and On-Line TOC Analyzers


The Sievers InnovOx Laboratory and On-Line Total Organic Carbon (TOC) Analyzers represent a true breakthrough in high TOC measurement technology and reliability. The InnovOx (short for innovative oxidation) can consecutively handle thousands of commonas well as difficult samples such as brine and cellulosewith unprecedented system uptime. The InnovOx offers unparalleled oxidation robustness, a dynamic linear working range of 0.5 to 50,000 ppm, and calibration curve stability for TOC analysis of process, environmental, and wastewater samples. Following are the most frequently used standards for the InnovOx. For the full list of standards, see pages 2627. When ordering, please use the applicable part number and quantity.
InnovOx On-Line and Laboratory TOC Analyzers

TOC Calibration Standards (250-mL bottles)


Part # CSTD 68310-01 Description Calibration 100 mg/L
Set includes: (1) 250-mL bottle containing 100 mg C/L as KHP.

CSTD 68410-01

Calibration 1,000 mg/L


Set includes: (1) 250-mL bottle containing 1,000 mg C/L as KHP.

CSTD 68450-01

Calibration 5,000 mg/L


Set includes: (1) 250-mL bottle containing 5,000 mg C/L as KHP.

CSTD 68520-01

Calibration 20,000 mg/L


Set includes: (1) 250-mL bottle containing 20,000 mg C/L as KHP.

CSTD 68100-01

Calibration Reagent Water


Set includes: (1) 250-mL bottle containing Reagent Water (<0.1 mg C/L at preparation).

TOC Calibration and Verification Standards (250-mL bottles)


Part # CSTD 68020-02 Description Calibration and Verification Kit 0 to 1,000-ppm range
Set includes: 250-mL bottles with the following standards: Calibration Reagent Water, 1-mg C/L KHP, 10-mg C/L KHP, 25-mg C/L KHP, 100-mg C/L KHP, 1,000-mg C/L KHP. Verification 50-mg C/L Sucrose, 500-mg C/L Sucrose.

CSTD 68551-01

Calibration and Verification 50,000 mg/L


Set includes: (1) 250-mL bottle containing 50,000-mg C/L Sucrose.

19

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS | STANDARDS FOR NON-SIEVERS BRANDS

The Convenience of Ready-made Standards


Producing standards in-house that comply with regulations and quality systems can be a challenge. Organizations must consider and control many variables, such as: Skilled, trained, and consistent performance of technicians Standard Operating Procedure (SOP) adherence and development Validated and wellmaintained equipment Purity of reagent water Purity of raw material Cleaning and maintaining dedicated glassware Cleanliness of vials Documentation development and maintenance for NIST traceability, GLPs, and/or cGMPs Many organizations have eliminated these variables and the costs, time, and complexity associated with in-house standards production by using Sievers Certified Reference Materials. They benefit from having reliable, ready-to-use standards at hand as needed, eliminating potential production delays and throughput reductions.

Standards for Non-Sievers Brand TOC Instruments


Sievers Standards are also compatible with most other laboratory-based TOC analyzers, such as: Shimadzu OI Analytical Skalar Teledyne-Tekmar

For more information, please contact us at geai@ge.com, or see page 8 for other options.

Custom Reference Materials for all TOC Instruments


If you need standards that are not listed, please contact us. We can produce any TOC reference material you may need. After reviewing your requirements, we can typically turn around a custom order within 48 hours. To fulfill your custom standard set request, please provide the following information: Source material (USP/NIST, Sucrose, KHP, etc.) and desired concentration Instrument make/model for which the standard will be used Container typically 40-mL glass vials Estimated number of sets required

Please send your request to orders@geinstruments.com, or see page 8 for other contact options.

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

20

TOC Sample Vials, Containers, and Cleaning Validation Kits


Sievers Certified (<10 ppb) TOC Vials
Sievers Certified (<10 ppb) TOC Vials are designed for use in critical pharmaceutical applications such as USP and EP Water testing as well as municipal water testing. Our certification to below 10 ppb TOC gives you confidence in the quality of your TOC measurements. In addition, they are: scrupulously cleaned in an ISO 9001 environment using a validated, automated process. manufactured by the global leader in TOC measurement technology and TOC standards. economical, with added savings on volume orders. reliable, with guaranteed performance.

21

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS | TOC SAMPLE VIALS, CONTAINERS AND CLEANING VALIDATION KITS

Sievers Certified TOC Vials are compatible with most TOC analyzer brands, including Sievers, Shimadzu, OI Analytical, Teledyne-Tekmar, and Skalar.
Part # CHMI 90606 Description Certified TOC Vials, 40-mL, 72 per case
Pre-cleaned and certified (<10 ppb) 40-mL glass vials with caps and Teflon-lined septa, 72 per case. These vials are the right choice for strict regulatory compliance testing.

CHMI 90207-01

Pre-cleaned 17-mL Glass Vials with Caps and Septa, 200 per case
Pre-cleaned 17-mL glass vials with caps and Teflon-lined septa, 200 per case. Certified (<10 ppb) TOC. Vial dimensions: 18 mm x 100 mm.

GE TOC Sample Vials


For environmental, municipal, and process applications, GE Analytical Instruments offers pre-cleaned 40-mL TOC sample vials. These vials are cleaned of organic residues with our advanced automated process in an ISO 9001 environment to ensure the quality of your TOC measurements. GE Analytical Instruments guarantees the performance of these vials.
Part # CHMI 90707-01 Description 40-mL Sample Vials, 72 per case
40-mL glass vials with Teflon-lined septa, 72 per case. These are non-certified sample vials suitable for general process monitoring. They are guaranteed to be (<100 ppb) TOC.

Additional Sample Containers


Part # CHMI 90810-01 Description
Pre-cleaned 60-mL glass vials with caps and septa, 72 per case. These Volatile Organic Analysis (VOA) vials are certified to meet EPA requirements. Vial dimensions: 26.5 mm x 144.5 mm. Teflon-lined septa thickness: 0.125 (3.2 mm). 35-mL Polypropylene Test Tubes for general sampling. These uncleaned, disposable containers have a round bottom with an open top. The test tubes are autoclavable. Tube dimensions: 20 mm x 150 mm. 30-mL Polysulfone Vials, 10 vials per pack. (1) pack containing 10 pre-cleaned 30-mL Polysulfone vials. Caps and septa must be ordered separately as HMI 90224-01. Pre-cleaned Septa and Cap Bonded. (1) pack containing 10 pre-cleaned 30-mL Polysulfone vials. Caps and septa must be ordered separately as HMI 90224-01.

CHMI 90800-01

CHMI 90303-01 HMI 90224-01

TOC Cleaning Validation Kits


Sievers TOC Cleaning Validation Kits feature low TOC background sampling swabs. Each kit includes (72) 40-mL Sievers Certified TOC Vials and (80) low-TOC Alpha Sampling Swabs. Alpha Sampling Swabs are manufactured and certified by the worldwide leader in critical cleaning products to assure extremely low-background TOC levels.
Part # CAPK 90600-01 Description
Cleaning Validation Kit contains (72) Sievers Certified TOC Vials (<10 ppb TOC) and (80) Certified Sampling Swabs (<50 ppb TOC).

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

22

Consumables, Reagents, and Replacement Parts


GE Analytical Instruments manufactures consumable parts and reagents (acid and oxidizer) for use with TOC instrumentation. Our parts and reagents are designed and built to exact specifications for GE Analytical Instruments analyzers and sensors. To manufacture the purest reagent for TOC measurement and prevent any contribution of TOC, we use ultrapure water from our proprietary water system. We also manage raw material purity through rigorous testing and control. Lot records, TOC background testing, and quality controls are in place to limit contamination. Each reagent comes with a Certificate of Analysis.

23

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

SIEVERS CERTIFIED REFERENCE MATERIALS | CONSUMABLES, REAGENTS, AND REPLACEMENT PARTS | 900 SERIES, 500 SERIES

Following are the most frequently used consumables, reagents, and replacement parts. For the full list, see page 28. When ordering kits, please use the applicable part number and quantity.

900 and 5310 C Series


Part # C900 MAINT Description 12-month 900 and 5310 C Series Consumable Kit
12-month Consumables Kit for the Sievers 900 and 5310 C Series. Includes: (4) Persulfate Reagents (150 mL ea.), (2) Acid Reagents, (2) UV Lamps, (1) Pump Tubing, and (1) Ion Exchange Resin Bed. Items delivered and billed on a quarterly schedule.

CAPF 90310-01

Acid Reagent Cartridge


300-mL Acid Reagent Cartridge for the Sievers 900 and 5310 C Series. Replacement is recommended after 6 months.

CAPF 90150-01

Low-capacity Oxidizer Cartridge


Low-capacity, 150-mL, Oxidizer Reagent Cartridge for the Sievers 900, 5310 C, and 800 Series. Replace after 3 months of use.

CAPF 90300-01

High-capacity Oxidizer Cartridge


High-capacity, 300-mL, Oxidizer Reagent Cartridge for the Sievers 900 and 5310 C Series. Replace after 3 months.

CARK 35001-01

UV Lamp, Multiple Instruments


UV Lamp for the Sievers 900 and 5310 C Series; Lamp lifetime is 6 months of operation.

CAPK 96004-01

Resin Bed Replacement


Replacement Resin Cartridge for the Sievers 900 and 5310 C Series Analyzers.

CATU 96200

Sample Pump Tubing


Sample Pump Tubing for the Sievers 900 and 5310 C Series Analyzers.

CPMK 36000-01

ICR Preventive Maintenance Kit


Annual Preventive Maintenance Kit for the 900 Inorganic Carbon Remover (ICR). Kit includes the degassing module, chemical trap, diaphragm replacement kit, and a 25-ppm C as sodium carbonate standard to verify operation of the ICR after maintenance.

CAPK 43030-01

Standalone Degasser Replacement


Degassing Module for the Inorganic Carbon Remover (ICR) used with the 900 Series and 5310 C Laboratory.

CAPK 43040-01

5310 C On-Line ICR Degassing Replacement


Degassing Module for the Inorganic Carbon Remover (ICR) used with the 5310 C On-Line.

500 RL Series
Part # CARK 35001-01 Description UV Lamp, Multiple Instruments
UV Lamp for the Sievers PPT, 900 Series, 500 RL Series, and CheckPoint. Average Lamp life is 6 months of operation.

CAPK 74160

500 RL DI Reservoir/Resin Replacement


DI Reservoir/Resin Replacement part. This part is a consumable that needs to be replaced every 2 years.

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

24

SIEVERS CERTIFIED REFERENCE MATERIALS | CONSUMABLES, REAGENTS, AND REPLACEMENT PARTS 5310 C SERIES, INNOVOX, CHECKPOINT

Consumables, Reagents, and Replacement Parts (continued)


Following are the most frequently used consumables, reagents, and replacement parts. For the full list, please see page 28. When ordering kits, please use the applicable part number and quantity.

InnovOx Series
Part # CAPK 68050-01 Description Reagent, Na2S2O8, 6-pack
Kit contains six pouches of dry sodium persulfate reagent. Each pouch makes 2L of 30% sodium persulfate solution.

CAPK 68051-01

Reagent, Na2S2O8, Single-pack


Kit contains one pouch of dry sodium persulfate reagent. The pouch makes 2L of 30% sodium persulfate solution. This kit is provided with new instrument shipments.

CSCH 68110-01

3M Hydrochloric Acid 2.5L


3M HCl acid container for the InnovOx Analyzer. This 2.5L reagent container can only be purchased and shipped in Europe, the Middle East, and Africa.

CSCH 68100-01

Hydrochloric Acid, 3M, 500 mL


0.5 liters of 3M HCl acid reagent for the InnovOx Analyzer. This container is drop shipped to the customers location within North America only.

CAPK 68120-01

Kit, Air Purifier, InnovOx


Replacement Air Filter Cartridge for the optional air filter system.

CAPK 68021-01

Kit, Sample Pump, InnovOx


Replacement Peristaltic Pump for the InnovOx Analyzer.

CheckPoint and CheckPointe


Part # CARK 35001-01 Description UV Lamp, Multiple Instruments
UV Lamp for the CheckPoint. Average lamp life is 6 months of operation.

CAPK 97010-01

CheckPoint Consumables Kit


(2) UV Lamps and (2) Pump Heads.

CAPK 97000-01

Pump Head Kit


Sample Pump Head Assembly Kit for CheckPoint.

25

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

Product Index
Sievers Certified Reference Materials
Part # Description Model
400 400 400 400 400 400 400 400 400 400 400 400

Part #
CSTD 74506 CSTD 74507 CSTD 74508-01 CSTD 74509-01 CSTD 74512 CSTD 74513 CSTD 74514 CSTD 74515 CSTD 74516 CSTD 74522 CSTD 74524 CSTD 74526 CSTD 74527-01 CSTD 74529-01 CSTD 74612 CSTD 74613 CSTD 74614 CSTD 74615 CSTD 74616 CSTD 74622 CSTD 74624 CSTD 74626 MIS 99999 STD KIT5M STD KIT5MS STD KIT5Q STD KIT5QS STD KIT5W STD KIT5WS CSTD 74409-01 CSTD 90000-01 CSTD 90001-01 CSTD 90002-01 CSTD 90003-01 CSTD 90004-01 CSTD 90005-01 CSTD 90007-01 CSTD 90008-01 CSTD 90009-01 CSTD 90010-01 CSTD 90011-01

Description
500 RL Super iOS Linearity Set 500 RL Super iOS Acc/Prec/Ver (TOC Only) 500 RL Super iOS Robustness Set 500 RL Super iOS Specificity Set 500 RL Super iOS Single-pt. Cal. A/Ver 500 RL Super iOS Single-pt. Validation 500 RL Super iOS Multi-pt. Validation

Model
500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL

CSTD 30021-03400 Standard SolutionRs CSTD 30022-02 CSTD 30023-03 CSTD 30024-02 CSTD 31005-02 CSTD 31006-02 CSTD 31010-03 CSTD 33000-01 CSTD 34001-03 CSTD 34005-03 STD 30025-03 STD 34002-01 STD KIT4M STD KIT4Q STD KIT4W CSTD 30001-01 CSTD 30002-01 CSTD 30003-01 CSTD 30004-01 CSTD 30005-01 CSTD 30006-01 CSTD 30007-01 CSTD 30008-01 CSTD 31001-01 CSTD 31002-01 CSTD 31007-01 CSTD 31015-01 CSTD 38001-02 CSTD 38101-02 CSTD 74401 CSTD 74402 CSTD 74403 CSTD 74405 CSTD 74406 CSTD 74407 CSTD 74408-01 CSTD 74429-01 CSTD 74501 CSTD 74502 CSTD 74503 CSTD 74505 400 TOC Calibration Standard 400 Reagent Water ControlRw 400 TOC Calibration Blank 400 TOC Calibration Standards Set 400 Linearity Standards Set 400 DI Accuracy and Precision Set 400 Equilibrated Water 400 DI Validation Set, CDI Firmware 400 Calibration Standards Set 400 System Suitability Solution 400 Validation Set, CUE

500 RL Super iOS Multi-pt. Cal. Set A&B 500 RL 500 RL Super iOS Multi-pt. Cal. A&B/Ver 500 RL 500 RL SiOS Single-pt. Cal/Ver (TOC Only) 500 RL 500 RL SiOS Multi-pt. Cal. Set (TOC Only) 500 RL 500 RL SiOS Multi-pt. Cal/Ver (TOC Only) 500 RL 500 RL Super iOS Rinse Vial Set 500 RL Super iOS JP Protocol Set (TOC) 500 RL Single-pt. Cal/Ver Set 500 RL Single-pt. Validation Set 500 RL Multi-pt. Calibration Set A & B 500 RL Multi-pt. Validation Set 500 RL Multi-pt. Cal. A&B/Ver Set 500 RL Single-pt. Cal/Ver Set TOC Only 500 RL Multi-pt. Cal/Ver Set (TOC Only) 500 RL Custom Standards Kit Annual Pharma Stds. Kit, monthly Annual Pharma Stds. Kit, quarterly Annual Pharma Stds. Kit, quarterly SiOS Annual Pharma Stds. Kit, weekly Annual Pharma Stds. Kit, weekly SiOS Specificity Set 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL/900

Annual Pharma Standards Kit, monthly 400


Annual Pharma Standards Kit, quarterly 400

Annual Pharma Standards Kit, weekly 800 TOC Calibration Standard 800 IC Calibration Standard 800 Calibration Blank Standard SolutionRs 800 TOC Standard Reagent Water ControlRw 800 TOC Standard Blank System Suit SolutionRss 800 Cal. Standards Set, Grab Mode 800 Cal. Standards Set, Autosampler 800 System Suitability Set, AS 800 TOC Standard Set 800 Validation Standards Set, Grab 800 Validation Standards Set, AS 500 RL Single-point Calibration Set A 500 RL Accuracy/Precision/Verification Set 500 RL System Suitability Set 500 RL Linearity Set 500 RL Acc/Prec/Ver Set (TOC Only) 500 RL Robustness Set 500 RL JP Protocol Standard Set (TOC) 500 RL Super iOS Acc/Prec/Ver Set 500 RL Super iOS System Suitability

400 800 800 800 800/900 800 800/900 800 800/900 800 800 800 800 800 800 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL 500 RL

500 RL Multi-pt. Cal. Set A&B (TOC Only) 500 RL

Annual Pharma Stds. Kit, monthly SiOS 500 RL

900 Multi-pt. Calibration Standards Set 900 900 Single-pt. Calibration Standards Set 900 900 Single-pt. Calibration Set, 5 mg/L 900 900 Single-pt. Calibration Set, 10 mg/L 900 900 Single-pt. Calibration Set, 25 mg/L 900 900 Single-pt. Calibration Set, 50 mg/L 900 900 Single-pt. Verification Set, 500 g/L 900 900 Single-pt. Verification Set, 1 mg/L 900 Single-pt. Verification Set, 2 mg/L 900 Single-pt. Verification Set, 5 mg/L 900 900 900

500 RL Single-point Cal. Set A (TOC Only) 500 RL

500 RL Super iOS Single-point Cal. Set A 500 RL

500 RL Super iOS Single-pt. Cal. A (TOC Only) 500 RL

900 Single-pt. Verification Set, 10 mg/L 900

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

26

Product Index
Sievers Certified Reference Materials
Part #
CSTD 90012-01 CSTD 90013-01 CSTD 90014-01 CSTD 90015-01 CSTD 90016-01 CSTD 90017-01 CSTD 90018-01 CSTD 90019-01 CSTD 90020-01 CSTD 90021-01 CSTD 90022-01 CSTD 90025 CSTD 90026 CSTD 90028 CSTD 90034 CSTD 90036 CSTD 90037-01 CSTD 90039-01 CSTD 31004-01 CSTD 31012-01 CSTD 31013-01 STD KIT8D STD KIT8M STD KIT8Q STD KIT8W CSTD 90031 CSTD 96000-01 CSTD 31003-03 CSTD 97006-01 CSTD 97010-01 CSTD 68020-02 CSTD 68040-02 CSTD 68100-01 CSTD 68310-01 CSTD 68410-01 CSTD 68450-01 CSTD 68520-01 CSTD 68551-01 CSTD 30030-01 STD 99999-01 CSTD 35050-01

Description

Model

Part #
CSTD 35051-01 CSTD 35052-01 STD 35053-01 STD 35054-01

Description
PPT, Cal. Standard, 400-mg/L Sucrose PPT, Verification Standard, 4 mg/L PPT, 4-mg/L TOC Challenge PPT 4-mg/L TOX Challenge

Model
PPT PPT PPT PPT

900 Single-pt. Verification Set, 25 mg/L 900 900 Single-pt. Verification Set, 50 mg/L 900 900 Turbo Calibration Set, 4 mg/L 900 Turbo Verification Set, 4 mg/L 900 Single-pt. Cal/Ver Set, 1 mg/L 900 Single-pt. Cal/Ver Set, 5 mg/L 900 Single-pt. Cal/Ver Set, 10 mg/L 900 Single-pt. Cal/Ver Set, 25 mg/L 900 Single-pt. Cal/Ver Set, 50 mg/L 900 Turbo Cal/Ver Set, 4 mg/L 900 Validation Set Only 900 Validation Set with Cal/Ver 900 1 mg/L Cal, 500 g/L Ver 900 Autoreagents Cal/Ver 900 Autoreagents Verification Set 900 Autoreagents Calibration Set 900 Robustness Set 900 JP Protocol Standard Set System Suitability Set Linearity Standard Set Accuracy and Precision Set Annual Pharma Standards Kit, daily Annual Pharma Stds. Kit, quarterly Annual Pharma Standards Kit, weekly 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 800/900 800/900 800/900 800/900 800/900 800/900

TOC Sample Vials, Containers, Cleaning Validation Kits


Part #
HMI 90224-01 HMI 90204-01 CHMI 90303-01 CHMI 90207 CAPK 90600-01 CHMI 90810 CHMI 90800 CHMI 90707-01 CHMI 90606

Description
Pre-cleaned Septa Pre-cleaned, 40-m/L Vials, 9-pack Polysulfone Vials, 10-pack Cleaning Validation Kit Pre-cleaned, 60-mL Glass Vials Polypropylene Test Tubes, 35 mL 40-mL Sample Vials, 72 per case Certified TOC Vials, 40 mL, 72 per case

Model
400 400 400 900 InnovOx InnovOx Multiple Multiple

Pre-cleaned, 17-mL Glass Vials with Caps 900

Annual Pharmal Standards Kit, monthly 800/900

Municipal TOC Verification Set (V1.40+) 5310 C 5310 C MP Calibration Set (V1.40 or later) 5310 C CheckPoint System Suitability Set CheckPoint TOC Linearity Set CheckPoint TOC Calibration Set InnovOx 0-1,000 ppm Cal. and Ver. InnovOx TOC Service Kit InnovOx Reagent Water InnovOx TOC Calibration, 100 mg/L InnovOx TOC Calibration, 1,000 mg/L InnovOx TOC Calibration, 5,000 mg/L InnovOx TOC Calibration, 20,000 mg/L InnovOx TOC Cal/Ver, 50,000 mg/L 400/500/CheckPoint Conductivity Std. TOC Custom Standards 400/CheckPoint CheckPoint CheckPoint InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx Multiple Multiple

PPT Conductivity Standard, 100 S/cm PPT

27

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

Product Index
Consumables, Reagents, and Replacement Parts
Part #
CATU 30100 C CATU 30150-01 CHFL 00063-01 PMK 33000-01 PMK 33001-01 SOL 33001-01 CACT 00060-01 CAPF 80010-02 CAQC 89300 CARE 00020-01 CASM 19200 G CATU 00646 CHMI 90221 CHMI 90225 A CPMK 34000-01 CPMK 35000-01 HMI 90224-01 HMI 90232-01 TOC MAINT CATU 00648-01 C900 MAINT CACT 00070-02 CAPF 90150-01 CAPF 90300-01 CAPF 90310-01 CAPK 43030-01 CAPK 43040-01 CAPK 96004-01 CAPK 96300-01 CAPK 96301-01 CAPK 96510 CAPK 96900-01 CAQC 89300 CARK 35001-01 CASM 96630 CATU 96200 CHFL 00081 CHFL 61000-01 CHFL 61010-01 CHTF 34000

Description
Pump Tubing Pump Tubing, 400/2244OL Fan Filter, 5-pack Maintenance Kit, 400, Black Pump Maintenance Kit, 400ES, Silver Pump 400 Vial, HCl Rinse Solution Chemical TrapIC Remover Acid Reservoir for 800/2244AP 800 Degassing Module UV Lamp Needle Assembly Pump Tubing Septa, 40 mL, 144-pack Autosampler Shuttle Diaphragm Pump Rebuild Kit 800 ICR Preventive Maintenance Kit Precleaned Septa and CapBonded 18-mm Tube Racks, 19 per set 12-month 800 Consumables Kit Pump Tubing 12-month 900 Series Consumable Kit ICR Chemical Trap Oxidizer Cartridge, 150 mL Oxidizer Cartridge, Hi Capacity, 300 mL Acid Cartridge Standalone Degasser Replacement 5310 C OL, ICR Degasser Replacement Kit, Resin Bed Replacement Ozone Destruct Kit for 900 Portable Ozone Destruct Kit for 900 On-line 900 AS Needle Assembly Kit On-line Municipal Water Add-On Degassing Module UV Lamp, Multiple Instruments Multi-holed Sipper Tube Assembly Sample Pump Tubing 50-micron Cartridge Filter 50-micron Bag Filter, PPE Disc Filter

Model
400 400 400 400 400 400 800 800 800 800/400 800 800 800 800 800 800 800 800 800 PPT 900/5310 C 900/5310 C 800/900/5310 C 900/5310 C 900/5310 C 900/5310 C 5310 C 900/5310 C 900 900 900/5310 C 5310 C 800/900/5310 C 900/500 /CkPt 900/5310 C 900/5310 C 900/5310 C 900/5310 C 900

Part #
CPMK 36000-01 CPMK 36000-01 CPMK 36100-01 ASM 71220-01 ASM 71235-01 ASM 71255-01 ASM 71260-01 ASM 71265-01 HMI 71125-01 HTF 71140-01 HTF 71141-01 CAPK 74010 CAPK 74160 CAPK 97000-01 CAPK 97010-01 CAPK 97310-01 CEMI 20240-01 CAPK 68021-01 CAPK 68050-01 CAPK 68051-01 CAPK 68100-01 CAPK 68110-01 CAPK 68120-01 CASM 68500-01 CATU 68002-01 CATU 68003-01 CATU 68500-01 CHFL 68100-01 CHMI 68340-03 CHMI 68341-01 CSCH 68100-01 CSCH 68110-01 CARK 34110 CHMI 89070 CHTF 94401 CHTF 94402

Description
900 ICR Preventive Maintenance Kit 900 ICR Preventive Maintenance Kit 900 ICR Reclaim Maintenance Kit Boron Reagent Refill Boron Pump Tubing Boron Set of Columns Boron Zero Column Boron Reagent Column 80-mm Filter Media, 5-pack Boron Inline 15-micron Filter Boron 15-micron SS Inline Filter Media 500 RL Sample Pump Heads Kit, Pump Head Assembly Consumables Kit Filter Element Kit Spare Battery InnovOx, Peristaltic Pump Assembly InnovOx, Oxidizer Reagent, 6-pack InnovOx, Oxidizer Reagent, Single InnovOx, Pinch Tubing Kit InnovOx, Reactor Seal Kit InnovOx, Air Filter Cartridge InnovOx, Autosampler Needle Kit InnovOx, Reagent Line, One Fitting InnovOx, Reagent Line, Two Fittings InnovOx, Autosampler Tubing Kit InnovOx, NDIR Filter InnovOx, 20-Mesh Coarse Screen InnovOx, 100-Mesh Fine Screen Disc InnovOx, 0.5L Acid (N. America Only) InnovOx, 2.5L Acid (Europe Only) Pump Diaphram Maintanance Kit Epson Thermal Printer Paper In-Line SS Filter, 60 micron Replacement Filter, 60 micron

Model
900 900/5310 C 900 Boron Boron Boron Boron Boron Boron Boron Boron 500 RL CheckPoint CheckPoint CheckPoint CheckPoint InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx InnovOx Multiple Multiple Multiple Multiple

500 RL DI Reservoir/Resin Replacement 500 RL

Capsule Filter, High Capacity, 40 micron 900/5310 C

AMERICAS T: +1 800 255 6964 E: orders@geinstruments.com | EUROPE, MIDDLE EAST, AFRICA T: +44 (0) 161 864 6800 E: geai.europe@ge.com

28

SIEVERS CERTIFIED REFERENCE MATERIALS AND CONSUMABLES | HOW TO ORDER

How To Order
The Americas
Tel: +1 800 255 6964 or +1 303 444 2009 Fax: +1 303-527 1797 Email: Send purchase orders to: orders@geinstruments.com Email: Send general inquiries to: geai@ge.com Web Store: http://www.geinstruments.com/store Office Hours: Monday through Friday, 10:00 am - 7:00 pm (EST)

Europe, Middle East and Africa


U.K. (European Headquarters) Tel: +44 (0) 161 864 6800 Fax: +44 (0) 161 864 6829 Email: geai.europe@ge.com Austria Tel: +0800 296133 Fax: +0800 296722 France Tel: +0800 90 53 64 Numro vert Fax: +44 161 864 68 29 Germany Tel: +0800 186 2054 Fax: +0800 182 2248 Ireland Tel: +1800 812734 or 353 876461756 Fax: +44 161 864 6829 or 353 15241651

Asia Pacific
All Countries geai.asia@ge.com China Tel: +(8621) 38777735 Fax: +(8621) 387774695 Email: geai.china@ge.com India Tel: +91 900 434 3626 Email: geai.india@ge.com Japan Email: geai.japan@ge.com

Credit Cards
We accept Visa, MasterCard, and American Express.

Rapid Shipping
Same day shipping is available for most products in North America and Europe. GE Analytical Instruments can deliver your product throughout the world from one of our standards and consumables manufacturing facilities in the US, UK, China, and India.

29

TO ORDER: ASIA PACIFIC E: geai.asia@ge.com

geai.china@ge.com geai.india@ge.com

geai.japan@ge.com

* Trademark of general Electric Company; may be registered in one or more countries.

The Americas GE Analytical Instruments 6060 Spine Road Boulder, CO 80301-3687 USA T +1 800 255 6964 T +1 303 444 2009 F +1 303 527 1797 geai@ge.com www.geinstruments.com

Europe/Middle East/Africa GE Analytical Instruments Unit 3, Mercury way Urmston, Manchester UK M41 7LY T +44 (0) 161 864 6800 F +44 (0) 161 864 6829 geai.europe@ge.com

Asia Pacific GE Analytical Instruments 7/F, Building 2, No. 5 Hua Tuo Rd. Seat No 001 ZhangJiang Hi-Tech Park, Pudong Shanghai, China 201203 T +(8621) 38777735 F +(8621) 38777469 geai.asia@ge.com

ISO

9001:2008
QUALITY MANAGEMENT SYSTEM

2011 General Electric Company. All rights reserved.

Das könnte Ihnen auch gefallen