Power factor control systems are suitable to reduce high costs for reactive energy.
Furthermore, they decrease high loads of electrical cables and distributions and increase their life expectance. Besides of that, the environmental pollution is reduced by
avoiding unnecessary CO2 expulsion.
Capacitors
Assembly
The space saving assembly of small format systems allows to build smaller
systems for wall mounting (unchoked) or standing cabinets (choked) in low cost
form. The slide-in construction makes it possible to build systems up to the highest power range.
Responsible consultants of electrical plants know, that the life expectance of compensation systems is significantely increased by equipping the system with filter
chokes. The power factor controller with its various functions offers more than just
power factor correction. Putting the system into service has been made easy by the
automatic configuration. While maintenance, the measurement of the single stage
currents makes it easy to find defective capacitors.
As a unique application worldwide, the power factor control system in combination with the integrated Procont can be delivered as energy saving center. This combines power factor correction with perfect energy management, as Procont offers
multiple measurements, maximum demand control and yearly switching clock
additionally, so it is a low cost alternative for several costly applications.
Dynamic Compensation
Note
Unchoked systems may not be used when:
- the rectifier load is more but 15% of the total load
- the system power is more but 35% of the transformer power.
- other choked capacitors are connected in the mains.
- critical audio frequencies in the range of 270-425Hz and with audio frequency rejection filters.
Audio frequency
Choke degree
Resonance frequency
>168Hz
p=14%
fr=134Hz
168-183Hz
p=14/5,67%
fr=134/210Hz
>250Hz
p=7%
fr=189Hz
>350Hz
p=5,67%
fr=210Hz
Technical Data
Technical Data
Guidelines
DIN, VDE 0660 Teil 500, IEC 439-1 and VDE 0560 Teil 41
Construction
Construction
Rated voltage
Control voltage
230V, 50Hz
Capacitor voltage
at p=5,67-7%
8h daily
30 min daily
5 min
1 min
Loss
Version
FK 5,67
FK 7
FK 14
I250Hz
0,565 IN
0,31 IN
0,086 IN
U250Hz
5%
5%
5%
Switchings of capacitors
100.000
Unlimited
Current transformer
.. /1A, .. /5A
Stage ratio
Disconnection
With discharge resistors according to VDE 0560, part 41 optionally with discharge chokes.
Installation height
Ambient temperature
Protection class
Cooling
Colour
440V
484V
506V
528V
572V
I350Hz
0,186 IN
0,134 IN
0,051 IN
at p=14%
525V
577V
604V
630V
682V
U350Hz
5%
5%
5%
Rated
power
kvar
Stage
power
kvar
Stage
ratio
Type
Part no.
Weight
kg
7,5
10
12,5
15
17,5
20
25
27,5
31
35
40
45
50
55
60
70
75
80
90
100
100
110
120
2,5/5
2,5/2,5/5
2,5/5/5
5/10
2,5/5/10
5/5/10
5/10/10
2,5/5/10
6,2/12,5
5/10/20
10/10/20
5/10/15..
10/20/20
5/10/20
10/20/30
10/20/40
12/12/25
20/20/40
10/20/30
12/12/25
20/40/40
10/20/40
20/20/40
1:2
1:1:2
1:2:2
1:2
1:2:4
1:1:2
1:2:2
1:2:4:4
1:2:2
1:2:4
1:1:2
1:2:3:3
1:2:2
1:2:4:4
1:2:3
1:2:4
1:1:2:2
1:1:2
1:2:3:3
1:1:2:4
1:2:2
1:2:4:4
1:1:2:2
JF440/7,5ER3KB4*
JF440/10ER4KB4 *
JF440/12,5ER5KB4*
JF440/15ER3KB4 *
JF440/17,5/ER7KB4*
JF440/20ER4KB4 *
JF440/25ER5KB4 *
JF440/27,5ER11KB6**
JF440/31ER5KB4 *
JF440/35ER7KB4 *
JF440/40ER4KB4*
JF440/45ER9KB6 **
JF440/50ER5KB6 *
JF440/55ER11KB6**
JF440/60ER6KB6*
JF440/70ER7KB6*
JF440/75ER6KB8**
JF440/80ER4KB8*
JF440/90ER9KB10**
JF440/100ER8KB10**
JF440/100ER5KB10*
JF440/110ER11KB10**
JF440/120ER6KB10 **
50.09.005
50.09.015
50.09.030
50.09.045
50.09.060
50.09.075
50.09.095
50.09.120
50.09.145
50.09.175
50.09.195
50.09.220
50.09.235
50.09.270
50.09.295
50.09.320
50.09.345
50.09.370
50.09.395
50.09.420
50.09.430
50.09.440
50.09.450
25
25
25
26
26
29
27
27
35
35
36
37
38
77
78
78
70
92
94
95
95
96
97
50.81.020
50.81.000
50.81.050
50.81.075
50.81.090
50.81.115
50.81.150
50.81.170
50.81.200
122
122
123
125
125
125
147
147
147
JF440/150ER6ES8184 **
JF440/150ER12ES8184 **
JF440/150ER6ES8184 **
JF440/160ER8ES8184 **
JF440/175ER7ES8184 **
JF440/175ER14ES8184 ***
JF440/180ER9ES8184 **
JF440/200ER4ES8184 **
JF440/200ER8ES8184 **
JF440/200/ER16ES8184 **
JF440/200ER10ES8184 **
JF440/240ER12ES8184 ***
JF440/250ER5ES8184**
JF440/250ER10ES8184 **
JF440/250ER20ES8184***
JF440/300ER6ES8184**
JF440/300ER12ES8184***
JF440/300ER24ES8184***
50.81.400
50.81.415
50.81.425
50.81.450
50.81.475
50.81.490
50.81.515
50.81.540
50.81.550
50.81.560
50.81.570
50.81.600
50.81.625
50.81.635
50.81.645
50.81.670
50.81.680
50.81.690
208
208
208
209
210
210
211
212
212
212
212
232
233
233
233
236
236
236
SO 100/800/400
SO 200/800/400
2903317
2903322
5
10
10/20/20
12/12/25
12/12/25
25/25/25
10/10/20
12/12/25
25/25/50
12/12/25
25/25/25
1:2:2
1:1:2
1:1:2 ..
1:1:1 ..
1:1:2
1:1:2:4
1:1:2 ..
1:1:2:4 ..
1:1:1 ..
JF440/50ER5ES8124 **
JF440/50ER4ES8124 **
JF440/75ER6ES8124 **
JF440/100ER4ES8124 **
JF440/100/ER10ES8124 **
JF440/100ER8ES8124 **
JF440/150ER6ES8124 **
JF440/150ER12ES8124 **
JF440/150ER6ES8124 **
25/25/50
12/12/25
25/25/25
20/20/40
25/50/50
12/12/25
20/40/40
50/50
25/25/50
12/12/25
20/20/40
20/20/40
50
25/25/50
12/12/25
50/50
25/25/50
12/12/25
1:1:2 ..
1:1:2:4 ..
1:1:1 ..
1:1:2 ..
1:2:2 ..
1:1:2 ..
1:2:2 ..
1:1 ..
1:1:2 ..
1:1:2:4 ..
1:1:2 ..
1:1:2 ..
1:1:1 ..
1:1:2 ..
1:1.2:4 ..
1:1:1 ..
1:1:2 ..
1:1:2:4 ..
Accessories
ES8124: H=1235, W=800, D=400, A1=374, A2=25,
A3=700, A4=100, A5=962
ES8184: H=1835, W=800, D=400, A1=374, A2=25,
A3=700, A4=100, A5=1480
*with power factor controller Prophi 3R **with power factor controller Prophi 6R
***with power factor controller Prophi 12R, Expansion units upon request,
Systems in insulated housing upon request, Audio remote filtering systems upon request
Stage
power
kvar
Stage
ratio
Type
Part no.
Weight
kg
7,5
10
12,5
15
17,5
20
25
27,5
31
35
40
45
50
55
60
70
75
80
90
100
100
110
120
2,5/5
2,5/2,5/5
2,5/5/5
5/10
2,5/5/10
5/5/10
5/10/10
2,5/5/10
6,2/12,5
5/10/20
10/10/20
5/10/15
10/20/20
5/10/20
10/20/30
10/20/40
12/12/25
20/20/40
10/20/30
12/12/25
20/40/40
10/20/40
20/20/40
1:2
1:1:2
1:2:2
1:2
1:2:4
1:1:2
1:2:2
1:2:4:4
1:2:2
1:2:4
1:1:2
1:2:3:3
1:2:2
1:2:4:4
1:2:3
1:2:4
1:1:2:2
1:1:2
1:2:3
1:1:2:4
1:2:2
1:2:4
1:1:2:2
JF440/7,5ER3MP4*
JF440/10ER4MP4 *
JF440/12,5ER5MP4*
JF440/15ER3MP4 *
JF440/17,5/ER7MP4*
JF440/20ER4MP4 *
JF440/25ER5MP4 *
JF440/27,5ER11MP6**
JF440/31ER5MP4*
JF440/35ER7MP4*
JF440/40ER4MP4*
JF440/45ER9MP6 **
JF440/50ER5MP6 *
JF440/55ER11MP6**
JF440/60ER6MP6 *
JF440/70ER7MP6*
JF440/75ER6MP8 **
JF440/80ER4MP8*
JF440/90ER9MP10**
JF440/100ER8MP10**
JF440/100ER5MP10 *
JF440/110ER11MP10**
JF440/120ER6MP10 **
50.03.005
50.03.015
50.03.030
50.03.045
50.03.060
50.03.075
50.03.095
50.03.120
50.03.145
50.03.175
50.03.195
50.03.220
50.03.245
50.03.270
50.03.295
50.03.320
50.03.345
50.03.370
50.03.395
50.03.420
50.03.430
50.03.440
50.03.450
10
10
10
11
11
14
14
24
26
26
28
28
29
29
30
31
32
35
37
38
38
39
40
JF440/50EK1MO84
JF440/50/2EK2MO84
JF440/50/3EK5MO84
JF440/50/3/EK4MO84
JF440/60/2EK3MO84
JF440/60/4EK6MO84
JF440/75/2EK3MO84
JF440/75/3EK3MO84
JF440/75/4EK6MO84
JF440/80/2EK2MO84
JF440/80/3EK4MO84
JF440/100/2EK2MO84
JF440/100/3EK4MO84
JF440/100/4EK4MO84
JF440/100/3EK5MO84
JF440/100/4EK8MO84
50.80.700
50.80.740
50.80.770
50.80.774
50.80.775
50.80.776
50.80.800
50.80.810
50.80.811
50.80.835
50.80.837
50.80.875
50.80.880
50.80.900
50.80.902
50.80.903
22
22
22
22
23
23
24
24
24
24
24
25
25
25
25
25
50
25/25
10/20/20
12/12/25
20/40
10/10/20
25/50
25/25/25
12/12/25
40/40
20/20/40
50/50
25/25/50
25/25/25
20/40/40
12/12/25
1:1
1:2:2
1:1:2
1:2
1:1:2
1:2
1:1
1:1:2:2
1:1
1:1:2
1:1
1:1:2
1:1:1
1:2:2
1:1:2:4
50.80.002
50.80.003
50.80.004
Control module
Accessories
Fixing bars for Rittal cabinets, left
Fixing bars for Rittal cabinets, right
29.12.435
29.12.436
Rated
power
kvar
Stage
power
kvar
Stage
ratio
Type
Part no.
Weight
kg
15
20
25
31
35
43,75
50
60
75
5/10
5/5/10
5/10/10
6,25/12,5
5/10/20
6/12/25
10/20/20
10/20/30
12/25/37
1:2
1:1:2
1:2:2
1:2:2
1:2:4
1:2:4 ..
1:2:2
1:2:3
1:2:3
JF440/15ER3KB6124FK7*
JF440/20ER4KB6124FK7*
JF440/25ER5KB6124FK7*
JF440/31/ER5KB6124FK7*
JF440/35ER7KB6124FK7*
JF440/43,75ER7KB6124FK7*
JF440/50ER5KB6124FK7*
JF440/60ER6KB6124FK7*
JF440/75ER6KB6124FK7*
50.51.020
50.51.040
50.51.080
50.51.110
50.51.150
50.51.180
50.51.210
50.51.225
50.51.240
112
113
116
118
122
138
142
158
167
SO100/600/400
29.03.311
Accessories
Socket 100mm high
60
75
100
100
100
100
110
120
140
150
175
200
200
200
250
250
300
300
350
400
450
500
550
600
10/20/30 1:2:3 ..
12/12/25 1:1:2 ..
25/25/50 1:1:2 ..
20/40/40 1:2:2
12/12/25 1:1:2:4 ..
10/20/30/401:2:3:4
10/20/40 1:2:4 ..
20/20/40 1:1:2 ..
20/40/40 1:2:2 ..
25/25/50 1:1:2 ..
25/50/50 1:2:2 ..
50
1:1:1 ..
25/25
1:1:2 ..
12/12/25 1:1:2:4 ..
50
1:1:1 ..
25/25/50 1:1:2 ..
50
1:1:1 ..
25/25/50 1:1:2 ..
50
1:1:1 ..
50
1:1.1 ..
50
1:1:1 ..
50
1:1:1 ..
50
1:1:1 ..
50
1:1:1 ..
JF440/60ER6ES8206FK7 **
JF440/75ER6ES8206FK7 **
JF440/100ER4ES8206FK7 **
JF440/100/ER5ES8206FK7 **
JF440/100ER8ES8206FK7 **
JF440/100ER10ES8206FK7 **
JF440/110ER11ES8206FK7 **
JF440/120ER6ES8206FK7 **
JF440/140ER7ES8206FK7 **
JF440/150ER6ES8206FK7 **
JF440/175ER7ES8206FK7 **
JF440/200ER4ES8206FK7 **
JF440/200ER8ES8206FK7 **
JF440/200ER16ES8206FK7 **
JF440/250/ER5ES8206FK7 **
JF440/250ER10ES8206FK7 **
JF440/300ER6ES8206FK7 **
JF440/300ER12ES8206FK7 ***
JF440/350ER7ES8206FK7 ***
JF440/400ER8ES8206FK7 ***
JF440/450ER9ES8206FK7 ***
JF440/500ER10ES8206FK7 ***
JF440/550ER11ES8206FK7 ***
JF440/600ER12ES8206FK7 ***
50.89.040
50.89.080
50.89.120
50.89.160
50.89.200
50.89.250
50.89.280
50.89.320
50.89.360
50.89.400
50.89.440
50.89.480
50.89.520
50.89.560
50.89.600
50.89.640
50.89.685
50.89.687
50.89.722
50.89.740
50.89.770
50.89.800
50.89.805
50.89.820
278
278
288
288
288
288
329
340
361
344
367
314
314
314
437
437
487
498
352/347
2x370
437/347
479/359
2x431
2x481
SO 100/800/600
SO 200/800/600
2903325 & 26
2903327 & 19
Accessories
Socket 100mm high
Socket 200mm high
8
15
*With power factor controller Prophi 3R **with Prophi 6R ***with Prophi 12R
Expansion cabinets and other dimensions upon request
The above mentioned slide-in construction is available in 500mm depth as well
The systems can be delivered with a choke degree of 5.67% against additional price
M086FK7 / FK14
Stage
power
kvar
10
12,5
20
25
40
50
20/2
25/2
30/2
40/2
40/3
50/2
75/2
80/2
100/2
10
12,5
20
25
40
50
10
12,5
10/20
20
10/10/20
25
25/50
40
50
Stage
ratio
1:1
1:1
1:2
1:1
1:1:2
1:1
1:2
1:1
1:1
Type
Part no.
Weight
kg
JF440/10EK1MO86FK7
JF440/12,5EK1MO86FK7
JF440/20EK1MO86FK7
JF440/25/EK1MO86FK7
JF440/40EK1MO86FK7
JF440/50EK1MO86FK7
JF440/20/2EK2MO86FK7
JF440/25/2EK2MO86FK7
JF440/30/2EK2MO86FK7
JF440/40/2EK2MO86FK7
JF440/40/3EK2MO86FK7
JF440/50/2EK2MO86FK7
JF440/75/2EK2MO86FK7
JF440/80/2EK2MO86FK7
JF440/100/2EK2MO86FK7
50.88.650
50.88.680
50.88.710
50.88.740
50.88.770
50.88.800
50.88.801
50.88.830
50.88.860
50.88.890
50.88.891
50.88.930
50.88.932
50.88.933
50.88.931
24
26
33
33
43
45
36
38
42
55
55
56
72
72
86
50.92.650
50.92.680
50.92.710
50.92.740
50.92.770
50.92.800
50.92.803
50.92.804
50.92.849
50.92.850
50.92.890
50.92.893
50.92.896
50.92.892
34
35
40
40
52
54
53
60
45
67
69
78
78
92
10
12,5
20
25
40
50
20/2
25/2
30/2
40/2
50/2
75/2
80/2
100/2
10
12,5
20
25
40
50
10
12,5
10/20
20
25
25/50
40
50
1:1
1:1
1:2
1:1
1:1
1:2
1:1
1:1
JF525/10EK1MO86FK14
JF525/12,5EK1MO86FK14
JF525/20EK1MO86FK14
JF525/25EK1MO86FK14
JF525/40EK1MO86FK14
JF525/50EK1MO86FK14
JF525/20/2E2MO86FK14
JF525/25/2EK2MO86FK14
JF525/30/2EK2MO86FK14
JF525/40/2EK2MO86FK14
JF525/50/2EK2MO86FK14
JF525/75/2EK2MO86FK14
JF525/80/2EK2MO86FK14
JF525/100/2EK2MO86FK14
50.80.002
50.80.003
50.80.004
Control module
M086FK7 / FK 14 Thy *1
Accessories
Fixing bars for Rittal cabinets, left
Fixing bars for Rittal cabinets, right
29.12.435
29.12.436
Rated
power
kvar
Stage
power
kvar
Stage
ratio
Type
Part no.
Weight
kg
15
20
25
31
35
43,75
50
60
75
5/10
5/5/10
5/10/10
6,25/12,5
5/10/20
6/12/25
10/20/20
10/20/30
12/25/37
1:2
1:1:2
1:2:2
1:2:2
1:2:4
1:2:4
1:2:2
1:2:3
1:2:3
JF525/15ER3KB6124FK14*
JF525/20ER4KB6124FK14*
JF525/25ER5KB6124FK14*
JF525/31/ER5KB6124FK14*
JF525/35ER7KB6124FK14*
JF525/43,75ER7KB6124FK14*
JF525/50ER5KB6124FK14*
JF525/60ER6KB6124FK14*
JF525/75ER6KB6124FK14*
50.51.520
50.51.540
50.51.580
50.51.610
50.51.650
50.51.680
50.51.710
50.51.725
50.51.729
123
124
128
130
134
152
173
184
195
SO100/600/400
29.03.311
Accessories
Socket 100mm high
60
75
100
100
100
100
110
120
140
150
175
200
200
200
250
250
300
300
350
400
450
500
550
600
10/20/30 1:2:3
12/12/25 1:1:2 ..
25/25/50 1:1:1 ..
20/40/40 1:2:2
12/12/25 1:1:2:4 ..
10/20/30/40 1:2:3:4
10/20/40 1:2:4:4
20/20/40 1:1:2 ..
20/40/40 1:2:2 ..
25/25/50 1:1:2 ..
25/50/50 1:2:2 ..
50
1:1:1 ..
25/25
1:1:2 ..
12/12/25 1:1:2:4 ..
50
1:1:1 ..
25/25/50 1:1:2 ..
50
1:1:1 ..
25/25/50 1:1:2 ..
50
1:1:1 ..
50
1:1.1 ..
50
1:1:1 ..
50
1:1:1 ..
50
1:1:1 ..
50
1:1:1 ..
JF525/60ER6ES8206FK14**
JF525/75ER6ES8206FK14**
JF525/100ER4ES8206FK14**
JF525/100/ER5ES8206FK14**
JF525/100ER8ES8206FK14**
JF525/100ER10ES8206FK14**
JF525/110ER11ES8206FK14**
JF525/120ER6ES8206FK14**
JF525/140ER7ES8206FK14**
JF525/150ER6ES8206FK14**
JF525/175ER7ES8206FK14**
JF525/200ER4ES8206FK14**
JF525/200ER8ES8206FK14**
JF525/200ER16ES8206FK14**
JF525/250/ER5ES8206FK14**
JF525/250ER10ES8206FK14**
JF525/300ER6ES8206FK14**
JF525/300ER12ES8206FK14***
JF525/350ER7ES8206FK14***
JF525/400ER8ES8206FK14***
JF525/450ER9ES8206FK14***
JF525/500ER10ES8206FK14***
JF525/550ER11ES8206FK14***
JF525/600ER12ES8206FK14***
50.93.040
50.93.080
50.93.120
50.93.160
50.93.200
50.93.250
50.93.280
50.93.320
50.93.360
50.93.400
50.93.440
50.93.480
50.93.520
50.93.560
50.93.600
50.93.640
50.93.685
50.93.690
50.93.722
50.93.742
50.93.770
50.93.800
50.93.805
50.93.920
317
318
368
413
380
387
397
379
400
375
407
420
421
371
478
490
500
500
424/365
2x424
2x478
364/484
3x365
3x424
SO 100/800/600
SO 200/800/600
2903325 & 26 8
2903327 & 19 15
Accessories
Socket 100mm high
Socket 200mm high
*with power factor controller Prophi 3R **with Prophi 6R ***with Prophi 12R
Expansion cabinets or other dimensions upon request
The combinded filtering system 14/5,67% is available under the type description FKK instead of FK14.
Type
Part no.
Capacity Dimensions
in F
+10% -5%
Weight
kg
525V
MKP5,8-620-D52
MKP4,3-525-D52
MKP9,8-570-D52
MKP8,6-525-D52
MKP10-525-D52
MKP7,6-440-D52
MKP12,5-525-D52
MKP9,1-440-D52
MKP8,0-610-D52
MKP11,2-440-D52
MKP12,1-440-D52
MKP15,1-440-D52
19.02.575
19.02.505
19.02.549
19.02.510
19.02.550
19.02.511
19.02.580
19.02.515
19.02.570
19.02.519
19.02.520
19.02.525
3x16
3x16,6
3x32
3x33,2
3x38,5
3x41,7
3x47,9
3x49,9
3x22
3x61,4
3x66,3
3x82,9
0,71
0,48
0,93
0,77
0,80
0,69
1,13
0,71
0,75
1,10
1,04
1,03
SK60
SK70
ASS
19.02.610
2,4
2,5
4,8
5
5,8
6,25
7,2
7,5
3,5
9,3
10
12,5
400V
2,6
2,7
5,2
5,4
6,3
6,8
7,8
8,1
3,77
10
10,8
13,4
415V
2,9
3,0
5,8
6
7
7,6
8,7
9,1
4,17
11,2
12,1
15,1
440V
3,5
3,6
7
7,2
8,33
10,5
5
-
480V
4,17
4,3
8,33
8,6
10
12,5
5,9
-
D60xH225mm
D60xH150mm
D70xH225mm
D60xH225mm
D70xH225mm
D60xH225mm
D70xH225mm
D60xH225mm
D60xH225mm
D70xH225mm
D70xH253mm
D70xH293mm
Type
Part no.
Weight
kg
2,5
5
8,3
10
12,5
15
16,7
20
25
30
33
40
50
60
70
75
80
90
100
JF440/2,5H/LK
JF440/5H/LK
JF440/8,3H/LK
JF440/10H/LK
JF440/12,5H/LK
JF440/15H/LK
JF440/16,7H/LK
JF440/20H/LK
JF440/25H/LK
JF440/30H/LK
JF440/33H/LK
JF440/40H/LK
JF440/50H/LK
JF440/60I/LK
JF440/70I/LK
JF440/75I/LK
JF440/80K/LK
JF440/90K/LK
JF440/100K/LK
50.61.000
50.61.050
50.61.100
50.61.150
50.61.200
50.61.250
50.61.300
50.61.350
50.61.400
50.61.450
50.61.600
50.61.650
50.61.700
50.61.750
50.61.780
50.61.820
50.61.860
50.61.900
50.61.945
5
5
7
8
8
9
9
10
10
15
15
19
19
20
20
20
21
21
21
Drawing H:
A1=120,
A5=395,
A1=120,
A5=395,
Type
Part no.
Weight
in kg
5
10
12,5
20
25
30
40
50
JF440/5LK-KB4-FK7
JF440/10LK-KB4-FK7
JF440/12,5LK-KB4-FK7
JF440/20LK-KB6-FK7
JF440/25LK-KB6-FK7
JF440/30LK-KB6-FK7
JF440/40LK-KB8-FK7
JF440/50LK-KB8-FK7
50.14.050
50.14.100
50.14.130
50.14.170
50.14.220
50.14.280
50.14.350
50.14.450
23
28
29
36
38
40
49
82
Power Capacitors
10
Rated
power
kvar
Type
Part no.
Weight
kg
5
10
12,5
20
25
30
40
50
JF525/5LK-KB4-FK14
JF525/10LK-KB4-FK14
JF525/12,5LK-KB4-FK14
JF525/20LK-KB6-FK14
JF525/25LK-KB6-FK14
JF525/30LK-KB6-FK14
JF525/40LK-KB8-FK14
JF525/50LK-KB8-FK14
50.15.050
50.15.100
50.15.130
50.15.170
50.15.220
50.15.280
50.15.350
50.15.420
24
29
30
37
39
51
63
83
Connection diameters
and fuses
Selection table for feeding cables and fuses
Power
kvar
Rated
current
A
Fuse per
phase
Feeding cablediameter
NYY-J
2
mm
Rated
current
A
Fuse per
phase
Feeding cable
diameter
NYY-J
2
mm
Rated
current
A
Fuse per
phase
Feeding cable
diameter
NYY-J
2
mm
5
7,5
10
12,5
17,5
25
30
37,5
40
45
50
55
65
70
75
80
100
110
125
150
160
175
200
225
250
275
300
7
11
14
18
25
36
43
54
58
65
72
79
94
101
108
116
144
159
181
217
231
253
289
325
361
397
433
20
20
25
36
50
63
63
80
80
100
100
125
160
160
160
200
200
250
315
315
400
400
400
500
500
630
630
4x2,5
4x2,5
4x4
4x6
4x10
4x16
4x16
4x25
4x25
3x35/16
3x35/16
3x35/16
3x35/16
3x70/35
3x70/35
3x70/35
3x95/50
3x120/70
3x150/70
3x185/95
2"3x95/50
2"3x95/50
2"3x120/70
2"3x120/70
2"3x150/70
2"3x185/95
2"3x185/95
6
8
11
14
19
28
33
41
44
50
55
61
72
77
83
88
110
121
138
165
176
193
220
248
275
303
330
10
20
20
25
36
50
63
63
63
80
100
100
125
125
125
200
200
200
200
250
315
315
400
400
400
500
500
4x2,5
4x2,5
4x2,5
4x4
4x6
4x10
4x16
4x16
4x16
4x25
4x25
3x35/16
3x35/16
3x35/16
3x50/25
3x70/35
3x70/35
3x70/35
3x70/35
3x120/70
3x150/70
3x150/70
2"3x95/50
2"3x95/50
2"3x120/70
2"3x120/70
2"3x150/70
4
6
8
10
15
21
25
31
34
38
42
46
54
59
63
67
84
92
105
126
134
147
168
188
209
230
251
20
20
20
20
25
36
50
50
50
63
63
80
80
100
100
100
125
160
200
200
200
250
250
315
315
400
400
4x2,5
4x2,5
4x2,5
4x2,5
4x4
4x6
4x10
4x16
4x16
4x16
4x16
4x16
4x25
3x35/16
3x35/16
3x35/16
3x50/25
3x70/35
3x70/35
3x70/35
3x70/35
3x120/70
3x120/70
3x120/70
3x185/95
2"3x95/50
2"3x95/50
Note:
1.) This table is valid for unchoked and choked compensation systems.
2.) The feeding cables are based on PVC-three phase cables with copper conductor and free laying in air at ambient temperature of +35.
3.) In case of differs, the respective regulations ( DIN VDE 0298 part 2) have to be respected. Compensation systems with a power over 300kvar have two separated
busbars and require two separated feedings.