Sie sind auf Seite 1von 40

Eddy Current Probes

for Nondestructive Testing


OLYMPUS NDT
Olympus NDT is a leading global
manufacturer of innovative nondestructive
testing instruments that are used in
industrial and research applications ranging
from aerospace, energy, automotive, and
electronics to manufacturing. Olympus
NDT instruments contribute to the quality
of products and add to the safety of
infrastructure and facilities. They include
flaw detectors, thickness gages, bond
testers, pulser-receivers, transducers, and
advanced systems for inline applications.
Our leading edge technologies include
ultrasound, ultrasound phased array, eddy
current, and eddy current array.
Olympus NDT offers products and
services from several high quality brands:
R/D Tech, Panametrics-NDT, NDT
Engineering, Sonic, and Nortec. For
many decades these brands have earned
excellent reputations for providing cost-
effective solutions and excellent support
and customer service.
Based in Waltham, Massachusetts, USA,
the company has sales and service
centers in all principal industrial locations
worldwide. Visit www.olympusNDT.com
for applications and sales assistance near
you.
NORTEC eddy current probes are designed
and manufactured by Olympus NDT in
Kennewick, WA, USA. We have a dedicated
staff of probe engineers available to help
you with your probe requirements - from
standard probes to application-specific
and custom designed probes. Optimal
performance in your eddy current test is
insured by selecting the right type of probe.
In addition to coil size and frequency, the
physical shape of a probe contributes to
a successful test. Flaw location and part
geometry determine whether a standard
probe can be used or if a custom design is
needed. This catalog features most of our
standard design probes that are available in
a wide range of diameters, frequencies, and
connector styles.
Tel: 509-736-2751 Fax: 509-735-4672
nortecsonic@olympusNDT.com
www.olympusNDT.com
Primary aPPlicaTioNs For sTaNDarD Probes
SuRfaCE pRObES are used for discovering faws both on and below
surfaces. Available in a broad frequency range, their diameters are
usually large for accommodating lower frequencies or scanning
large areas.
pENCil pRObES have smaller diameter housing coils built for
higher frequencies. Applications are usually limited to surface faws
because of higher frequency.
RighT aNglE pENCil pRObES reach areas inaccessible to pencil
probes. They normally employ the same coils and frequencies as
pencil probes.
haNd hEld bOlT hOlE pRObES have coils located at right
angles to the probe direction, and are rotated by hand with the
fastener removed. Standard and custom diameters are available
with absolute and differential coils.
SCaNNER dRivEN bOlT hOlE pRObES are used with mechanical
devices for automatically rotating and indexing into hole. Absolute
and differential coils are common at higher frequencies of 500 kHz
and 2 MHz. They bear close tolerances and are highly reliable.
dONuT pRObES are designed to inspect aircraft fastener holes
with fasteners in place, and can be used on uneven fastener holes.
Various inside/outside diameters and frequencies for different size
fasteners and differing materials are available.
SlidiNg pRObES are designed to inspect aircraft fastener holes
with fasteners in place, at higher scan rates than donut probes.
Common sizes and frequencies using the refection coil techniques
are often applied in major airframe inspection requirements.
id pRObES usually have a frequency range of 5 kHz to 100 kHz
made in absolute or differential confgurations. Many body styles
are available depending on the inside surfaces of tubes to be
inspected. Most probe diameters are made to meet customers
requirements.
Od pRObES are usually designed for a frequency range of 5 kHz
to 100 kHz and available in absolute, differential and switchable
confgurations. Tubes to be inspected are passed through the coil
for absolute or differential faw detection at high speeds.
Nortec Eddy Current Probes - Contents
Eddy Current Probe Selection 2
Eddy Current Probe Design 2
PowerLink Technology 3
Rotating Scanner Probes 4
Bolt Hole Probes for Spitfire, MiniMite (4 pin Fischer),
Hocking and Rohmann Scanners 4
Bolt Hole Probes for Spitfire, MiniMite (4 pin Fischer),
Hocking and Rohmann Scanners 5
Bolt Hole Probes for RA19, RA2000 and
MiniMite (4 pin Lemo) Hand Held Scanners 6
Bolt Hole Probes for RA19, RA2000 and
MiniMite (4 pin Lemo) Hand Held Scanners 7
Special Scanner Probes for RA19, RA2000, and
MiniMite (4 pin Lemo) Hand Held Scanners 8
Special Scanner Probes for Spitfire, MiniMite (4 pin Fischer),
Hocking and Rohmann Scanners 9
Bolt Hole Probes for Nortec

PS-5 Stainless Steel and


Aluminum Scanners 10
Bolt Hole Probes for Nortec

PS-5 Stainless Steel and


Aluminum Scanners 11
Bolt Hole Probes for PS-2 and PS-3 Scanners 12
Non-Contact Bolt Hole Probes
for RC RECHII Scanners 13
Bolt Hole Probes for PS-4 Scanner
(Contact and Non-Contact) 14
Scanner Probe Kits 15
RA19, RA2000 and MiniMite (4 pin Lemo)
Bolt Hole Probe Kits 15
Detachable Bolt Hole Probes 16
Standard Manual Bolt Hole Probes,
Absolute and Differential 16
PowerLink Manual Bolt Hole Probes,
Absolute and Differential 17
3551 Pencil Probes 18
Nortec

3551 Pencil Probes 18


Nortec

3551L PowerLink Pencil Probes 19


Detachable Pencil Probes 20
Nortec

Standard Detachable Pencil Probes 20


Nortec

PowerLink Detachable Pencil Probes 21


Nortec

Standard Detachable
Metal Shaft Pencil Probes 22
Nortec

PowerLink Detachable
Metal Shaft Pencil Probes 23
Detachable Surface Probes 24
Nortec

Standard Detachable Surface Probes 24


Nortec

PowerLink Detachable Surface Probes 25


Ring/Donut Probes 26
Nortec

Standard Ring/ Donut Probes (SPO Series) 26


Nortec

PowerLink Ring/ Donut Probes (SPO Series) 27


Nortec

Detachable Ring/ Donut Probes 28


Nortec

PowerLink Detachable Ring/ Donut Probes 29


Sliding Probes 30
Nortec

Standard Sliding Probes 30


Nortec

PowerLink Sliding Probes 31


Conductivity Probes 32
Nortec

Standard Conductivity Probes 32


Nortec

PowerLink Conductivity Probes 33


ID Probes 34
Nortec

ID Probes 34
OD Probes 35
Nortec

OD Probes 35
General Purpose Probe Kits 36
Documentation Inside Back Cover
wwwolympusNDTcom
Eddy Current Probes
GENERaL CONSIDERaTIONS
Likeothernondestructivetestingmethods,eddycurrentcanperformavarietyoftestsdependingonthetypeofprobebeing
used.Optimalperformancethereforeisensuredbycarefulprobeselection.Thiscatalogoffersinformationandspecifcations
forselectingprobestomeetyourinspectionrequirements.
INSTRumENTS
Impedance Plane Display EC instrumentstakethegreatestadvantageofthemanydifferentprobedesignsavailable.Mostcan
beusedwithbridgeandrefectionprobetypes,displayingphaseandamplitudechanges.Unitsfeaturingenhancedfltering,
frequencyrange,sensitivityandrecordingshouldbeconsideredforadditionalversatility.
maTERIaL aND TEST REquIREmENTS
ThematerialforinspectionoftendetermineswhetherECcanbeusedornot.Nonmagneticconductivematerialrangingfrom.6%
IACSto110%IACSoffersthebestopportunityforasuccessfulECtest.Testcriteriaarebasedonpenetrationdepth,sensitivity,
signaltonoiseratioandscanspeed.
Detectable faw size, resolution and accuracy requirements must also be determined. Eddy current is traditionally used to
determine material thickness, non-conductive coating thickness, conductivity and plating measurement, and cracks. Crack
detectionofsurfaceandsubsurfacefawsisthemostpopularapplication.
Frequencyoftheinstrumentandprobeisdecidedbythematerialbeinginspectedandthesizeofthedefectsrequestedfor
detection.The Nortec

EC Slide Rule can be of assistance in defning this test parameter by calculating the best depth of
penetration,fawangleandfrequency.
PROBE SELECTION
Advancededdycurrentinspectionrequirestheuseofmanydifferentcoilconfgurations.Absoluteanddifferentialcoilsare
available in both bridge and refection designs. Depending on the test, some are very small in diameter and others can be
quitelarge.Acompromiseisusuallymadetogivethebestdepthofpenetration,greatestsensitivitytothesmallestdefects,and
smallestcoildiameter.
Inadditiontocoilsizeandfrequency,thephysicalshapeofaprobecontributestoasuccessfulECtest.Flawlocationandpart
geometrydeterminewhetherastandardprobecanbeusedorifacustomdesignisneeded.Becausethecoilmustpassover
thefaworbeincloseproximitytoit,theprobebodyrequiresaccurategeometricspecifcations.
STaNDaRD PROBE DESIGNS
Cost,uniformityandavailabilitymakeitdesirabletousestandardprobeswheneverpossible.
Manystandarddesigns,withvariousfrequencies,diametersanddetectioncircuitsarelistedinthiscatalog.
nortecsonic@olympusNDTcom
PowerLink

Technology
Nortec

probeshavealwayssetthestandardforPerformance, rePeatability andQuality. Thenewgenerationof


Nortec

PowerLink Technology Sensors continuetobuildonitsreputation,nowprovidinganadditionalValueAdded
capabilitywhenusedonStaveleyInstrumentsnewlineofeddycurrentinstruments.
POwERLINK EDDy CuRRENT PROBE FEaTuRES
Automaticprobesetupincludingfrequency,gain,flters,horizontalandverticalposition,andalarmgates*.
Commoncableconfgurationallowsbothbridgeandrefectionprobestobeoperatedwiththesamecable.
Providesprobemodelnumber,serialnumber,screendataandspaceforcommentsonprintoutfromNortecneweddy
currentinstruments.
ProbesarebackwardcompatiblewithearlierversionsofNortec

instruments,liketheNDT-19eandNDT-4,withthe
appropriatecable.
Probesarecapableofbeingreprogrammedastheneedarises.
PowerLinkcanbebypassedtoallowtheprobetobeusedforanyapplicabletest.
LevelIIIprogramming(userprogrammable)supportedintheNortec

WorkStationandPowerStationinstrumentation.
*Any command featured in the instrument documentation may be programmed into the Nortec

PowerLinkprobes.
SPECIaL PROBE DESIGNS*
Probesaredesignedtomeetcustomersspecialrequirements.Theaccuracyofadesignistestedbyplacingatestcoilovera
defectthroughmatchingsurfacesofthepartandtheECprobe.
Specialconfgurationsareusedinmanyapplications.Thebroadestrangeisemployedintheinspectionofaircraftenginesand
airframes.ThesearedevelopedincooperationwiththecustomerandStaveleyInstrumentsdesigners.
CustomdevelopmentisdoneroutinelyatOlympusNDT.Morethanthirtyyearsofexperienceinsolvingdiffcultproblems
maximizestheperformanceofinstrumentandprobe.OurunderstandingofImpedance Plane Analysis andtheperformanceof
certainECcomponents,areaguidetoexpectedresultsshownonanECinstrumentliketheNortec

2000S.Impedancechanges
(Z=X+R)aredirectresultsofchangesintheinductivereactanceorresistanceoftheECfeldinducedintoapart.Bothphase
andamplitudechangesareviewableontheinstrumentscreen.
Coilconfgurations,diameterandfrequencyaffectsensitivity,butcalibrationstandardsarealsoimportanttothesuccessofthe
ECtest.Calibrationstandardsareusuallybaseduponthematerialtobeinspectedcontainingknownnotchesofminimumsize
fordetection.ThesenotchesaremadebyEDMprocessingforbestresults,butanarrowsawcutisadequateincertainsituations.
ConductivitymeasurementscanbecertifedtoN.I.S.T.
4 wwwolympusNDTcom
Rotating Scanner Probes
BOLT HOLE PROBES FOR SPITFIRE, mINImITE (4 PIN FISCHER), HOCKING aND ROHmaNN SCaNNERS
SPO-5965expandingprobeshavealongwearing
plastictipandstainlesssteelbackshell.Probesare
fttedwitha4pinFischerconnector.Theseprobes
aresimilartoSPO-5000probesbutareexpanded
totheirlargerdiameter.Theyaredesignedtoallow
theuseofthesameprobewhenholesarereamed
toalargerdiameter.Theyarealsousefultocheck
unusualholesizeswhenafxedsizeprobeis
unavailable.
Theseprobesusearefectiondifferentialtypecoil
operatinginthe00kHztoMHzrange.This
makesthemsuitableforaluminumstructuresas
wellaslowconductivitymaterials.Theseprobes
arealsoavailableinkits.
SPO-5965
How to Order:ProvidePartNumber,Description,andWorkingLength.
Otherdiametersandworkinglengthsavailable.ContacttheSensorsdepartmentat509-76-751formoreinformation.
>0.250" 0.l00" - 0.249"
w/L w/L w/L
Probe Description Part number Working length (W/l)
SPO-5965.156-.187 90061 1.75 44mm
SPO-5965.187-.18 919979 1.75 44mm
SPO-5965.18-.50 919980 .00 50mm
SPO-5965.50-.81 919981 .00 50mm
SPO-5965.81-.1 91998 .00 50mm
SPO-5965.1-.75 91998 .00 50mm
SPO-5965.75-.47 919978 .00 50mm
SPO-5965.47-.500 919984 .00 50mm
SPO-5965.500-.56 919985 .00 50mm
SPO-5965.56-.65 90156 .00 50mm
SPO-5965.65-.687 90157 .00 50mm
SPO-5965.687-.750 90158 .00 50mm
SPO-5965.750-.81 90159 .00 50mm
nortecsonic@olympusNDTcom 5
BOLT HOLE PROBES FOR SPITFIRE, mINImITE (4 PIN FISCHER), HOCKING aND ROHmaNN SCaNNERS
SPO-59probesareahybridoftheoriginalRAprobesandare
fttedwitha4pinFischerconnector.
Theseprobesusearefectiondifferentialtypecoiloperatinginthe
00KHztoMHzrange.Thismakesthemsuitableforaluminum
structuresaswellaslowconductivitymaterials.
The standard stock types are identifed in fractions (1/).The
actualprobesizeisdiameter.010(.5mm)belowthissizeto
provideclearance.Identifyspecialorderswithdecimals(.505).
Theseprobeswillbemadetothediameterorderedwithoutunder-
sizing.Theworkinglength(WL)requiredshouldalsobestated.
Theseprobesarealsoavailableinkits.
>0.250" 0.l00" - 0.249"
w/L w/L
Rotating Scanner Probes
SPO-5393
How to Order:ProvidePartNumber,Description,andWorkingLength.
Otherdiametersandworkinglengthsavailable.ContacttheSensorsdepartmentat509-76-751formoreinformation.
Probe Description Part Number Working Length (W/L)
SPO-595/ 919999 .00 50mm
SPO-59/16 90000 .00 50mm
SPO-597/ 9005 .00 50mm
SPO-591/4 919987 .00 50mm
SPO-599/ 919988 .00 50mm
SPO-595/16 919989 .00 50mm
SPO-5911/ 919990 .00 50mm
SPO-59/8 919991 .00 50mm
SPO-591/ 91999 .00 50mm
SPO-597/16 91999 .00 50mm
SPO-591/ 919994 .00 50mm
SPO-599/16 919995 .00 50mm
SPO-595/8 919996 .00 50mm
SPO-5911/16 919997 .00 50mm
SPO-59/4 919998 .00 50mm
6 wwwolympusNDTcom
Ra Probes
How to Order:ProvidePartNumber,Description,andWorkingLength.
Rotating Scanner Probes
BOLT HOLE PROBES FOR Ra19, Ra2000 aND mINImITE (4 PIN LEmO) HaND HELD SCaNNERS
RAprobesaremadefromdurablestainlesssteel
and are non-contact probes. Probes are ftted
witha4pinLemoconnector.
Theseprobesusearefectiondifferentialtypecoil
operatinginthe00KHztoMHzrange.This
makesthemsuitableforaluminumstructuresas
wellaslowconductivitymaterials.
The standard stock types are identified in
fractions (1/). The actual probe size is
diameter .010 (.5mm) below this size to
provideclearance.Identifyspecialorderswith
decimals(.500).Theseprobeswillbemadeto
thediameterorderedwithoutunder-sizing.The
workinglength(WL)requiredshouldalsobestated.Theseprobesarealsoavailableinkits.
Otherdiametersandworkinglengthsavailable.ContacttheSensorsdepartmentat509-76-751formoreinformation.
Diameters
</ 0.250"
w/L
w/L
Diameters
>/ 0.25l"
0.40
Probe Description Part Number Probe Description Part Number Working Length (W/L)
RA-5/S 91690 RA-1/4S 90484 0.5 6mm
RA-5/16S 90486 0.0 8mm
RA-/16 90481 RA-1/4 9048 1.10 8mm
RA-7/ 9048 RA-9/ 91691 1.10 8mm
RA-5/16 90485 RA-11/ 9169 1.50 8mm
RA-/8 90487 RA-1/ 9169 1.50 8mm
RA-7/16 90488 RA-1/ 90489 1.50 8mm
RA-9/16 91694 RA-5/8 90490 1.50 8mm
RA-11/16 91695 RA-/4 91696 1.50 8mm
nortecsonic@olympusNDTcom 7
BOLT HOLE PROBES FOR Ra19, Ra2000 aND mINImITE (4 PIN LEmO) HaND HELD SCaNNERS
SPO-564 expanding probes have a long
wearingplastictipandstainlesssteelbackshell.
Probesarefttedwitha4pinLemoconnector.
Theseareexpandableto0%abovetheirnominal
diameter.Theyaredesignedtoallowtheuseof
thesameprobewhenholesarereamedtoalarger
diameter. They are also useful to check
unusualholesizeswhenafxedsizeprobeis
unavailable.
These probes use a reflection differential
type coil operating in the 500 KHz to
MHz range.This makes them suitable for
aluminumstructuresaswellaslowconductivity
materials.These probes are also available in
kits.
SPO-3564
How to Order:ProvidePartNumber,Description,andWorkingLength.
Rotating Scanner Probes
>0.25l" 0.l87" - 0.250"
w/L
0.l50" - 0.l86"
w/L
w/L
0.40
Otherdiametersandworkinglengthsavailable.ContacttheSensorsdepartmentat509-76-751formoreinformation.
Probe Description Part Number Working Length (W/L)
SPO-564.156-.187 90078 1.10 8mm
SPO-564.187-.18 91715 1.10 8mm
SPO-564.18-.50 917154 1.10 8mm
SPO-564.50-.81 917155 1.10 8mm
SPO-564.81-.1 917156 1.50 8mm
SPO-564.1-.75 917157 1.50 8mm
SPO-564.75-.47 917158 1.50 8mm
SPO-564.47-.500 917159 1.50 8mm
SPO-564.500-.56 917160 1.50 8mm
SPO-564.56-.65 918785 1.50 8mm
SPO-564.65-.687 918786 1.50 8mm
SPO-564.687-.750 918787 1.50 8mm
SPO-564.750-.81 918788 1.50 8mm
8 wwwolympusNDTcom
SPECIaL SCaNNER PROBES FOR Ra19, Ra2000, aND mINImITE (4 PIN LEmO) HaND HELD SCaNNERS
Theseprobesarefttedwitha4pinLemoconnectorandRAstylecoilsoperatinginthe500KHztoMHzrange.
Thismakesthemsuitableforfrstlayeraluminumstructures.
1. Surface inSPection ProbeS (raised head fasteners)- for
inspecting the immediate area surrounding a raised head
fastener.
. Surface inSPection ProbeS -foruseindetectingfaws
emanatingfromunderfastenerheads.Inspectioncanbedone
withfushfastenersinstalled.Probeusesballbearingguide
foralignment.
. Surface inSPection ProbeS (non counterSink)-for
inspectingtheimmediateareaoutsideofanoncountersink
hole(fastenermustberemoved).Allprobeshaveapilotshaft
foreaseinalignment.Fivesizesareavailable.
4. counterSink ProbeS-foruseindetectingfawsincountersinkswiththefastenersremoved.Allprobesaredesignedfor
thestandard100countersinkunlessotherwisespecifed.Allprobeshaveapilotshaftforeaseinalignment.Fivesizesare
available.
Special Probes
How to Order:ProvidePartNumberandDescription.
Rotating Scanner Probes

Countersink Part Number Non-Countersink Part Number
SPO-401-5/ 916594 SPO-986-5/ 916604
SPO-401-/16 916595 SPO-986-/16 916605
SPO-401-7/ 916596 SPO-986-7/ 916606
SPO-401-1/4 916597 SPO-986-1/4 916607
SPO-401-5/16 916598 SPO-986-5/16 916608
Surface Inspection Part Number Surface Inspection (Raised Fastener) Part Number
SPO-906-(5/to/16) 91660 SPO-408-5/ 91660
SPO-44-(/16to7/) 916599 SPO-407-5/16 916601
nortecsonic@olympusNDTcom 9
Rotating Scanner Probes
Special Probes
How to Order:ProvidePartNumberandDescription.
SPECIaL SCaNNER PROBES FOR SPITFIRE, mINImITE (4 PIN FISCHER), HOCKING aND ROHmaNN SCaNNERS
Theseprobesarefttedwitha4pinFischerconnectorandRAstylecoilsoperatinginthe500KHztoMHzrange.Thismakes
themsuitableforfrstlayeraluminumstructures.
1. Surface inSPection ProbeS (raised head
fasteners)- for inspecting the immediate area
surroundingaraisedheadfastener.
. Surface inSPection ProbeS-foruseindetecting
flaws emanating from under fastener heads.
Inspectioncanbedonewithfushfastenersinstalled.
Probeusesballbearingguideforalignment.
. Surface inSPection ProbeS(noncountersink)-
forinspectingtheimmediateareaoutsideofanon
countersink hole (fastener must be removed). All
probeshaveapilotshaftforeaseinalignment.Five
sizesareavailable.
4. counterSink ProbeS- for use in detecting
fawsincountersinkswiththefastenersremoved.
All probes are designed for the standard 100
countersinkunlessotherwisespecifed.Allprobes
haveapilotshaftforeaseinalignment.Fivesizesareavailable.

Countersink Part Number Non-Countersink Part Number
SPO-5787-5/ 981 SPO-5786-5/ 986
SPO-5787-/16 98 SPO-5786-/16 987
SPO-5787-7/ 98 SPO-5786-7/ 988
SPO-5787-1/4 984 SPO-5786-1/4 989
SPO-5787-5/16 985 SPO-5786-5/16 990
Surface Inspection Part Number Surface Inspection (Raised Fastener) Part Number
SPO-665-(5/to/16) 991 SPO-5784-5/ 99
SPO-666-(/16to7/) 99 SPO-5785-5/16 994
10 wwwolympusNDTcom
Rotating Scanner Probes
PS-5 Scanner Probes
How to Order:ProvidePartNumberandDescription.
BOLT HOLE PROBES FOR NORTEC PS-5 STaINLESS STEEL aND aLumINum SCaNNERS
Theseprobesaremanufacturedwithachoiceofbridge/absolute,bridge/differentialor
refection/differentialcoilsinavarietyoffrequencyranges.Theyhavealongwearing
plasticexpandabletipandstainlesssteelbackshell.Theseprobesareexpandableto0%
abovetheirnominaldiameter.Theyaredesignedtoallowtheuseofthesameprobe
whenholesarereamedtoalargerdiameter.Theyarealsousefultocheckunusualhole
sizeswhenafxedsizeprobeisunavailable.
Standardprobesareavailablewitha1.5(8mm)workinglength,otherworkinglengths
andprobediametersareavailable.
Theseprobesarealsoavailableinkits.Themostpopularkitislistedonpage14,other
kitsareavailable.

Probe Description Part # Probe Description Part # Probe Description Part #


PS5/100KHZ-500KHZ/A.156 91768 PS5/500KHZ-MHZ/D.156 917648 PS5/00KHZ-1MHZ/RD.156 917569
PS5/100KHZ-500KHZ/A.187 91769 PS5/500KHZ-MHZ/D.187 91750 PS5/00KHZ-1MHZ/RD.187 917570
PS5/100KHZ-500KHZ/A.18 91760 PS5/500KHZ-MHZ/D.18 917649 PS5/00KHZ-1MHZ/RD.18 917571
PS5/100KHZ-500KHZ/A.50 91761 PS5/500KHZ-MHZ/D.50 91751 PS5/00KHZ-1MHZ/RD.50 91757
PS5/100KHZ-500KHZ/A.81 9176 PS5/500KHZ-MHZ/D.81 917650 PS5/00KHZ-1MHZ/RD.81 91757
PS5/100KHZ-500KHZ/A.1 9176 PS5/500KHZ-MHZ/D.1 9175 PS5/00KHZ-1MHZ/RD.1 917574
PS5/100KHZ-500KHZ/A.4 91764 PS5/500KHZ-MHZ/D.4 917651 PS5/00KHZ-1MHZ/RD.4 917575
PS5/100KHZ-500KHZ/A.75 91765 PS5/500KHZ-MHZ/D.75 9175 PS5/00KHZ-1MHZ/RD.75 917576
PS5/100KHZ-500KHZ/A.406 91766 PS5/500KHZ-MHZ/D.406 91765 PS5/00KHZ-1MHZ/RD.406 917577
PS5/100KHZ-500KHZ/A.47 91767 PS5/500KHZ-MHZ/D.47 91754 PS5/00KHZ-1MHZ/RD.47 917578
PS5/100KHZ-500KHZ/A.468 91768 PS5/500KHZ-MHZ/D.468 91765 PS5/00KHZ-1MHZ/RD.468 917579
PS5/100KHZ-500KHZ/A.500 91769 PS5/500KHZ-MHZ/D.500 91755 PS5/00KHZ-1MHZ/RD.500 917580
PS5/100KHZ-500KHZ/A.51 917640 PS5/500KHZ-MHZ/D.51 917654 PS5/00KHZ-1MHZ/RD.51 917581
PS5/100KHZ-500KHZ/A.56 917641 PS5/500KHZ-MHZ/D.56 91756 PS5/00KHZ-1MHZ/RD.56 91758
PS5/100KHZ-500KHZ/A.59 91764 PS5/500KHZ-MHZ/D.59 917655 PS5/00KHZ-1MHZ/RD.59 91758
PS5/100KHZ-500KHZ/A.65 91764 PS5/500KHZ-MHZ/D.65 91757 PS5/00KHZ-1MHZ/RD.65 917584
PS5/100KHZ-500KHZ/A.656 917644 PS5/500KHZ-MHZ/D.656 917656 PS5/00KHZ-1MHZ/RD.656 917585
PS5/100KHZ-500KHZ/A.687 917645 PS5/500KHZ-MHZ/D.687 917657 PS5/00KHZ-1MHZ/RD.687 917586
PS5/100KHZ-500KHZ/A.718 917646 PS5/500KHZ-MHZ/D.718 917658 PS5/00KHZ-1MHZ/RD.718 917587
PS5/100KHZ-500KHZ/A.750 917647 PS5/500KHZ-MHZ/D.750 91758 PS5/00KHZ-1MHZ/RD.750 917588
nortecsonic@olympusNDTcom 11
Rotating Scanner Probes
PS-5 Scanner Probes
How to Order:ProvidePartNumberandDescription.
BOLT HOLE PROBES FOR NORTEC

PS-5 STaINLESS STEEL aND aLumINum SCaNNERS


Probe Kit, PS5 AF
Part # 9217666 NSN 6635-01-415-9099
Probe Kit, PS5 Absolute
Part # 9230230
Probe Kit, PS5 Differential
Part # 9230231
PS5/00KHZ-1MHZ/RD.156 PS5/100KHZ-500KHZ/A.156 PS5/500KHZ-MHZ/D.156
PS5/00KHZ-1MHZ/RD.187 PS5/100KHZ-500KHZ/A.187 PS5/500KHZ-MHZ/D.187
PS5/00KHZ-1MHZ/RD.18 PS5/100KHZ-500KHZ/A.18 PS5/500KHZ-MHZ/D.18
PS5/00KHZ-1MHZ/RD.50 PS5/100KHZ-500KHZ/A.50 PS5/500KHZ-MHZ/D.50
PS5/00KHZ-1MHZ/RD.81 PS5/100KHZ-500KHZ/A.81 PS5/500KHZ-MHZ/D.81
PS5/00KHZ-1MHZ/RD.1 PS5/100KHZ-500KHZ/A.1 PS5/500KHZ-MHZ/D.1
PS5/00KHZ-1MHZ/RD.4 PS5/100KHZ-500KHZ/A.4 PS5/500KHZ-MHZ/D.4
PS5/00KHZ-1MHZ/RD.75 PS5/100KHZ-500KHZ/A.75 PS5/500KHZ-MHZ/D.75
PS5/00KHZ-1MHZ/RD.406 PS5/100KHZ-500KHZ/A.406 PS5/500KHZ-MHZ/D.406
PS5/00KHZ-1MHZ/RD.47 PS5/100KHZ-500KHZ/A.47 PS5/500KHZ-MHZ/D.47
PS5/00KHZ-1MHZ/RD.468 PS5/100KHZ-500KHZ/A.468 PS5/500KHZ-MHZ/D.468
PS5/00KHZ-1MHZ/RD.500 PS5/100KHZ-500KHZ/A.500 PS5/500KHZ-MHZ/D.500
PS5/00KHZ-1MHZ/RD.51 PS5/100KHZ-500KHZ/A.51 PS5/500KHZ-MHZ/D.51
PS5/00KHZ-1MHZ/RD.56 PS5/100KHZ-500KHZ/A.56 PS5/500KHZ-MHZ/D.56
PS5/00KHZ-1MHZ/RD.59 PS5/100KHZ-500KHZ/A.59 PS5/500KHZ-MHZ/D.59
PS5/00KHZ-1MHZ/RD.65 PS5/100KHZ-500KHZ/A.65 PS5/500KHZ-MHZ/D.65
PS5/00KHZ-1MHZ/RD.656 PS5/100KHZ-500KHZ/A.656 PS5/500KHZ-MHZ/D.656
PS5/00KHZ-1MHZ/RD.687 PS5/100KHZ-500KHZ/A.687 PS5/500KHZ-MHZ/D.687
PS5/00KHZ-1MHZ/RD.718 PS5/100KHZ-500KHZ/A.718 PS5/500KHZ-MHZ/D.718
PS5/00KHZ-1MHZ/RD.750 PS5/100KHZ-500KHZ/A.750 PS5/500KHZ-MHZ/D.750
1 wwwolympusNDTcom
Rotating Scanner Probes
BOLT HOLE PROBES FOR PS-2 aND PS-3 SCaNNERS
The SA and SD scanner bolt hole probes are ftted with 4 pin Switchcraft
connectors and available with absolute or differential coils in bridge
confguration.
The SA t ype absol ut e probe has a shi el ded 100 kHz coi l f or
aluminumstructures.SDtypedifferentialprobeshave500kHzshieldedcoilsfor
aluminumand/orlowconductivitymaterials,andprovideincreasedsensitivity
tosmalldefects.
Otherfrequenciesareavailable.ProbebodymaterialisofblackDelrinunless
otherwisespecifed.
7,
7,
7,
example: 9216318 SD 16
Part# Absolute(SA) ProbeSizeinX/64
Differential(SD)
Sa and SD Scanner Probes
How to Order:ProvidePartNumberandDescription.
How to Order Nonstandard Probes:
example: SD r 0.325 500kHz 2
Absolute(SA) AddRifcoil ProbeDiameter Frequency WorkingLength
Differential(SD) isrecessed
Specialorderprobesshouldbeidentifedwithsizeindecimals(0.505)Workinglength(WL)requiredshouldbestatedifdifferentfromthe
standard.0.IfcoilisrecessedaddR.Note:Probesbelow0.160areunshieldedandhavenoexpansionslotorcheeks.Probesbelow
0.0havenoballend.
*Otherdiametersandworkinglengthscanbemadetospecialorder.StandardfrequencyrangeforSAabsoluteprobesis100KHzto500KHz.
StandardfrequencyrangeforSDdifferentialprobesis500KHztoMHz.
Diameter of Probe or Hole
SA Absolute
Shielded
Part Number
SD Differential
Shielded
Part Number Working Length
.156 4.0mm 5/ SA-10 91699 SD-10 91615 1.4 6mm
.187 4.7mm /16 SA-1 91601 SD-1 91616 1.4 6mm
.18 5.5mm 7/ SA-14 9160 SD-14 91617 1.4 6mm
.50 6.mm 1/4 SA-16 9160 SD-16 91618 1.4 6mm
.81 7.1mm 9/ SA-18 91604 SD-18 91619 1.4 6mm
.1 7.9mm 5/16 SA-0 91605 SD-0 9160 .0 76mm
.4 8.7mm 11/ SA- 91606 SD- 9161 .0 76mm
.75 9.5mm /8 SA-4 91607 SD-4 916 .0 76mm
.406 10.mm 1/ SA-6 91608 SD-6 916 .0 76mm
.47 11.1mm 7/16 SA-8 91609 SD-8 9164 .0 76mm
.500 1.7mm 1/ SA- 91610 SD- 9165 .0 76mm
.56 14.mm 9/16 SA-6 91611 SD-6 9166 .0 76mm
.65 15.9mm 5/8 SA-40 9161 SD-40 9167 .0 76mm
.687 17.5mm 11/16 SA-44 9161 SD-44 9168 .0 76mm
.750 19.0mm /4 SA-48 91614 SD-48 9169 .0 76mm
nortecsonic@olympusNDTcom 1
RC Scanner Probes
How to Order:ProvideProbeType,ProbeDiameter,andWorkingLength
example: rcb 0.240 Wl.800
ProbeType ProbeDiameter WorkingLength
NON-CONTaCT BOLT HOLE PROBES FOR RC RECHII SCaNNERS
TheRCScannerBoltholeprobesarefttedwitha4pinSwitchcraftconnector.
RCprobesaremadeofstainlesssteel.
Thestandardcoilsusedarerefectiondifferential.Theyofferawidefrequency
range(typically500KHztoMHz)withgoodsignal-to-noiseratio.
RCprobesaremanufacturedfortheRECHIIHighSpeed(1500rpm)Scanner.
TheseprobesarenotinterchangeablewiththePS-orPS-scanners.
Non-ContactRCstyleprobesarenormallyordered.010(.5mm)lessthanthe
holediameterforclearance.Theywilloperatewithmoreclearance(depending
ondefectsize)withreducedsensitivity.
AllRECHIIprobesarecustommadetocustomerspecifcations.
When ordering:
AllRCprobesizesshouldbeidentifedusingdecimals(.___).Theprobewillbemadetothediameterorderedwithoutunder
sizing.Workinglengthsshouldberequestedwhenplacinganorder.
RCScannerProbesareavailablefrom.050to1.500indiameter.TheyaredesignedtobeusedwiththeRECHIIIIscanner
andNDT-5LwithRECHIIoptioninstruments.Theyareusedtodetectminutecracksanddefectsintitanium,inconelandother
lowconductivityalloys.
RCS
Available
Diameters
RCA
Available
Diameters
RCB
Available
Diameters
RCC
Available
Diameters
0.050to0.19 0.10to0.169 0.170to0.64 0.65to1.500
Rotating Scanner Probes
14 wwwolympusNDTcom
Rotating Scanner Probes
BOLT HOLE PROBES FOR PS-4 SCaNNER (CONTaCT aND NON-CONTaCT)
ThestandardPS-4probesarefttedwitha6pinLemoconnector.Theseprobesaremadewithan
aluminumbackshellandahighqualityplastictip.
Thestandardcoilsusedarerefectiondifferential,double-ended,shielded.Theyofferawide
frequencyrange(typically500Khz-4Mhz)withoptimumsignaltonoiseratio.Theyareusedfor
detectingminutecracksanddefectsintitanium,inconelandotherlowconductivityalloys.These
probesareofferedinthreedifferentstyles:
1. Snc (Staveley non-contact)arenormallyordered.010(.5mm)lessthantheholediameter
forclearance.Thewilloperatewithmoreclearance(dependingonthedefectsize)withreduced
sensitivity.
. Scr (Staveley contact receSSeD) are expandable to maintain surface contact.They can
beexpandedupto10%oftheirnominalsize.SCRcoilsarerecessedslightlybelowthecontact
surfacewhichreducesscanningnoiseanddoesnotrequireprotectivetape.
. Sc (Staveley contact)arethesameasSCRprobesexceptthecoilisnotrecessed.Theyprovide
thebestsensitivitybutrequireprotectivetape.
SCR, SNC, and SC Scanner Probes
How to Order:ProvideProbeType,ProbeDiameter,andFrequency
example: Scr 0.239 -S/2
ProbeType ProbeDiameter FrequencyinMHz
-S/2 = 2MHz
-S/6 = 6MHz
Probe types:
Scr - Staveley Contact Recessed
Sc - Staveley Contact
Snc - Staveley Non-Contact
AllPS-4probesarecustommadetocustomerspecifcations.
nortecsonic@olympusNDTcom 15
minimite, Ra19 and Ra2000 4-Pin Lemo Scanner Kits
How to Order:ProvideStockPartNumberandDescription
Ra19, Ra2000 aND mINImITE (4 PIN LEmO) BOLT HOLE PROBE KITS
Stainless Steel, Non Contact Stainless Steel, Non Contact
TwoProbeKitsareavailable:
TheStanDarD kitbringstogethereightofourmostpopularsizesina
convenientcarryingcase.
TheDeluxe kitismadeof15sizesrangingfrom5/to/4ina
convenientcarryingcase.
Bothkitsarecomprisedofourstock,highquality,stainlesssteelprobes.Allaremanufactured.010
(.5mm)lessthanthefractionalsizesshown.Standardworkinglengthsaresupplied.
Expanding Probes, Contact Expanding Probes, Contact
exPanDable kitcontainseightSPO-564probestocoverholesizesfrom.187(5mm)toover
.500(1mm).Theseprobeshaveanexpansionrangeofabout0%.
Scanner Probe Kits
Standard RA Kit
Part Number 9216656
Deluxe RA Kit
Part Number 9216657
Expandable Kit (SPO-3564)
Part Number 9216658
90481 RA-/16 91690 RA-5/ 91715 SPO-564.187-.18
9048 RA-7/ 9169 RA-1/ 917154 SPO-564.18-.50
9048 RA-1/4 90481 RA-/16 917155 SPO-564.50-.81
91485 RA-5/16 90488 RA-7/16 917156 SPO-564.81-.1
90487 RA-/8 9048 RA-7/ 917157 SPO-564.1-.75
90488 RA-7/16 90489 RA-1/ 917158 SPO-564.75-.47
90489 RA-1/ 9048 RA-1/4 917159 SPO-564.47-.500
90490 RA-5/8 91694 RA-9/16 917160 SPO-564.500-.56
CarryingCase 91691 RA-9/ CarryingCase
90490 RA-5/8
90845 RA-5/16
91695 RA-11/16
9169 RA-11/
91696 RA-/4
90487 RA-/8
CarryingCase
16 wwwolympusNDTcom
Detachable Bolt Hole Probes
manual Bolt Hole Probes
How to Order:ProvidePartNumberandDescription
example: 9216156 b/ 100kHz-500kHz /a .250
PartNumber BoltHole FrequencyRange Absolute Probe/Hole
(*BR if Refection coil) (D if Differential coil) Diameter

WhenorderingcablesthestandardinstrumentconnectorsuppliedwillbetheNortec8pinBurndyunlessotherwisespecifed.
Adaptorsareavailabletomatchdifferentinstrumentmanufacturers.
Note:Probes0.156andbelowareunshieldedandhavenoexpansionslot.Probesbelow0.6havenoballend.Collaris
non-removableonprobes0.50to0.51indiameter.
STaNDaRD maNuaL BOLT HOLE PROBES, aBSOLuTE aND DIFFERENTIaL
Thedetachableboltholeprobesaremanualprobesavailablewithabsoluteordifferentialcoils
inbridgeorrefectionconfgurations.Internalreferencecoilsensureaccuratebalancewithout
externaladaptors.
Thedetachableconnectorallowstheprobetoberotatedwhileholdingthecablestationary.
Cablesaresoldseparately.
7,
7,
Probe
Diameter
Absolute Shielded
Part
Number
Differential Shielded
Part
Number
Working Length
.156 B/100KHZ-500KHZ/A.156 91615 B/500KHZ-MHZ/D.156 916168 1.0 5mm
.187 B/100KHZ-500KHZ/A.187 916154 B/500KHZ-MHZ/D.187 916169 1.0 5mm
.18 B/100KHZ-500KHZ/A.18 916155 B/500KHZ-MHZ/D.18 916170 1.0 5mm
.50 B/100KHZ-500KHZ/A.50 916156 B/500KHZ-MHZ/D.50 916171 .0 51mm
.81 B/100KHZ-500KHZ/A.81 916157 B/500KHZ-MHZ/D.81 91617 .0 51mm
.1 B/100KHZ-500KHZ/A.1 916158 B/500KHZ-MHZ/D.1 91617 .0 51mm
.4 B/100KHZ-500KHZ/A.4 916159 B/500KHZ-MHZ/D.4 916174 .0 51mm
.75 B/100KHZ-500KHZ/A.75 916160 B/500KHZ-MHZ/D.75 916175 .0 51mm
.406 B/100KHZ-500KHZ/A.406 916161 B/500KHZ-MHZ/D.406 916176 .0 51mm
.47 B/100KHZ-500KHZ/A.47 91616 B/500KHZ-MHZ/D.47 916177 .0 51mm
.500 B/100KHZ-500KHZ/A.500 91616 B/500KHZ-MHZ/D.500 916178 .0 51mm
.56 B/100KHZ-500KHZ/A.56 916164 B/500KHZ-MHZ/D.56 916179 . 8mm
.65 B/100KHZ-500KHZ/A.65 916165 B/500KHZ-MHZ/D.65 916180 . 8mm
.687 B/100KHZ-500KHZ/A.687 916166 B/500KHZ-MHZ/D.687 916181 . 8mm
.750 B/100KHZ-500KHZ/A.750 916167 B/500KHZ-MHZ/D.750 91618 . 8mm
ForBridgeProbesusedetachablecableC/SC/6(Stock#911016)orC/RA/6(Stock#911017).StandardfrequencyrangeforAbsolute
Probesis100KHzto500Khz.StandardfrequencyrangeforDifferentialProbesis500KHztoMHz.
*Whenorderingrefectioncoils(specialorder)omitpartnumberandorderbydescription.ForRefectionTypeProbes(specialorder)
usedetachablecableCR/SC/6(Stock#91149)orCR/RA/6(Stock#91140).Lengthsshownareapproximate.
nortecsonic@olympusNDTcom 17
PowerLink manual Bolt Hole Probes
How to Order:ProvidePartNumberandDescription
example: 9222218 bl/ 100kHz-500kHz /a .250
PartNumber BoltHole FrequencyRange Absolute Probe/Hole
(*BRL if Refection coil) (D if Differential coil) Diameter
note:Probes0.156andbelowareunshieldedandhavenoexpansionslot.Probesbelow0.6havenoballend.Collar
isnon-removableonprobes0.50to0.51indiameter.
POwERLINK maNuaL BOLT HOLE PROBES, aBSOLuTE aND DIFFERENTIaL
ThePowerLinkdetachableboltholeprobesaremanualprobesavailablewithabsoluteor
differentialcoilsinbridgeorrefectionconfgurations.Internalreferencecoilsensureaccurate
balancewithoutexternaladaptors.Allprobesaresuppliedwithanadjustablecollar.Common
cablecompatibilityamongmostPowerLinkeddycurrentprobesallowsonecabletooperate
probes in either bridge or refection confguration. All Nortec

PowerLink eddy current


probesarebackwardcompatibletoNortec

NDT-19andNDT-4instruments.CablesCL/
SC/6forNortec

000seriesandC/SC/67PforNDT-19andNDT-4instruments,aresold
seperately.
PowerLinktechnologyoffersunmatchedperformancewhenusedwithStaveleysneweddy
currentinstrumentation.PowerLinkfeaturesautomaticproberecognitionanddocumentation,
aswellasprovidingtheoptimumintegrationbetweeninstrumentandsensor.
7,
7,
*When or der i ng
r ef l ect i on coi l s
(special order) omit
part number and
orderbydescription.
Lengths shown are
approximate.
Detachable Bolt Hole Probes
Probe
Diameter
Absolute Shielded
Part
Number
Differential Shielded
Part
Number
Working Length
.156 B/100KHZ-500KHZ/A.156 91615 B/500KHZ-MHZ/D.156 916168 1.0 5mm
.187 B/100KHZ-500KHZ/A.187 916154 B/500KHZ-MHZ/D.187 916169 1.0 5mm
.18 B/100KHZ-500KHZ/A.18 916155 B/500KHZ-MHZ/D.18 916170 1.0 5mm
.50 B/100KHZ-500KHZ/A.50 916156 B/500KHZ-MHZ/D.50 916171 .0 51mm
.81 B/100KHZ-500KHZ/A.81 916157 B/500KHZ-MHZ/D.81 91617 .0 51mm
.1 B/100KHZ-500KHZ/A.1 916158 B/500KHZ-MHZ/D.1 91617 .0 51mm
.4 B/100KHZ-500KHZ/A.4 916159 B/500KHZ-MHZ/D.4 916174 .0 51mm
.75 B/100KHZ-500KHZ/A.75 916160 B/500KHZ-MHZ/D.75 916175 .0 51mm
.406 B/100KHZ-500KHZ/A.406 916161 B/500KHZ-MHZ/D.406 916176 .0 51mm
.47 B/100KHZ-500KHZ/A.47 91616 B/500KHZ-MHZ/D.47 916177 .0 51mm
.500 B/100KHZ-500KHZ/A.500 91616 B/500KHZ-MHZ/D.500 916178 .0 51mm
.56 B/100KHZ-500KHZ/A.56 916164 B/500KHZ-MHZ/D.56 916179 . 8mm
.65 B/100KHZ-500KHZ/A.65 916165 B/500KHZ-MHZ/D.65 916180 . 8mm
.687 B/100KHZ-500KHZ/A.687 916166 B/500KHZ-MHZ/D.687 916181 . 8mm
.750 B/100KHZ-500KHZ/A.750 916167 B/500KHZ-MHZ/D.750 91618 . 8mm
18 wwwolympusNDTcom
3551 Pencil Probes
NORTEC

3551 PENCIL PROBES


The551typepencilprobesaresuppliedwithabuilt-insmalldiameter,lownoisecableandanadjustablecollar.Theyare
availablewithabsoluteordifferentialcoilsinbothbridgeandrefectionconfgurations(shieldedandunshielded).Shielded
coilshaveaneffectivesensitiveareaofapproximately0.08(mm)indiameter.ProbeswillbesuppliedwithaNortec

8pin
Burndyconnectorunlessotherwisespecifed.
Nortec

3551 Pencil Probes


How to Order:ProvidePartNumberandDescription
example: 9204914 3551f 100kHz
PartNumber Type Frequency
The551probehasastandardO.D.=0.18
*Probediameter=0.5
Frequency Range Absolute Unshielded Part Number Absolute Shielded Part Number
Standard Absolute (Bridge type non-PowerLink)
50Khz-100Khz 55150Khz 918 551F50Khz 9184
100Khz-500Khz 551100Khz 904910 551F100Khz 904914
500Khz-1Mhz 551500Khz 904911 551F500Khz 904915
1Mhz-Mhz 5511Mhz 90491 551F1Mhz 904916
Mhz-4Mhz 551Mhz 90491 551FMhz 904917
4Mhz-6Mhz 5514Mhz 918 551F4Mhz 9185
Refection Absolute (non-PowerLink)
1Khz-100Khz 551R1Khz 91659* 551RF1Khz 91659*
100Khz-1Mhz 551R100Khz 9191 551RF100Khz 9194
1Mhz-Mhz 551R1Mhz 919 551RF1Mhz 9195
Mhz-6Mhz 551RMhz 919 551RFMhz 9196
Frequency Range Differential Unshielded Part Number Differential Shielded Part Number
Standard Differential (Bridge type non-PowerLink)
100Khz-500Khz 551D100Khz 916590 551DF100Khz 916591
500Khz-Mhz 551D500Khz 9186 551DF500Khz 9189
Mhz-4Mhz 551DMhz 9187 551DFMhz 9148
4Mhz-6Mhz 551D4Mhz 9188 551DF4Mhz 9190
Refection Differential (non-PowerLink)
500Khz-Mhz 551RD500Khz 9197 551RDF500Khz 9199
Mhz-6Mhz 551RDMhz 9198 551RDFMhz 91400
nortecsonic@olympusNDTcom 19
Nortec

3551L Pencil Probes


How to Order:ProvidePartNumberandDescription
example: 9230122 3551fl 100kHz
PartNumber Type Frequency
3551 Pencil Probes
NORTEC

3551L POwERLINK PENCIL PROBES


The551Ltypepencilprobesaresuppliedwithabuilt-insmalldiameter,lownoisecableandanadjustablecollar.Theyare
availablewithabsoluteordifferentialcoilsinbothbridgeandrefectionconfgurations(shieldedandunshielded).Shielded
coilshaveaneffectivesensitiveareaofapproximately0.08(mm)indiameter.Probeswillbesuppliedwitha16pinLemo
connector.
The551probehasastandardO.D.=0.18
*Probediameter=0.5
frequency range absolute unshielded Part number absolute Shielded Part number
Standard absolute (bridge type )
50Khz-100Khz 551L50Khz 90115 551FL50Khz 9011
100Khz-500Khz 551L100Khz 90116 551FL100Khz 901
500Khz-1Mhz 551L500Khz 90117 551FL500Khz 901
1Mhz-Mhz 55L11Mhz 90118 551FL1Mhz 9014
Mhz-4Mhz 55L1Mhz 90119 551FLMhz 9015
4Mhz-6Mhz 55L14Mhz 9010 551FL4Mhz 9016
refection absolute
1Khz-100Khz 551RL1Khz 9010* 551RFL1Khz 90107*
100Khz-1Mhz 551RL100Khz 90104 551RFL100Khz 90108
1Mhz-Mhz 551RL1Mhz 90105 551RFL1Mhz 90109
frequency range Differential unshielded Part number Differential Shielded Part number
Standard Differential (bridge type)
100Khz-500Khz 551DL100Khz 9017 551DFL100Khz 9011
500Khz-Mhz 551DL500Khz 9018 551DFL500Khz 901
Mhz-4Mhz 551DLMhz 9019 551DFLMhz 901
4Mhz-6Mhz 551DL4Mhz 9010 551DFL4Mhz 9014
refection Differential
500Khz-Mhz 551RDL500Khz 90111 551RDFL500Khz 9011
Mhz-6Mhz 551RDLMhz 9011 551RDFLMhz 90114
0 wwwolympusNDTcom
Detachable Pencil Probes

Nortec

Standard Detachable Pencil Probes


How to Order:ProvidePartNumberandDescription
example: 9213408 P /100kHz-500kHz/ a
PartNumber Pencil FrequencyRange Absolute
(PRifRefection) (DifDifferential)
NORTEC

STaNDaRD DETaCHaBLE PENCIL PROBES


TheNortec

standarddetachablepencilprobesaresuppliedwithanadjustablecollarandahighqualityquickrelease
connector.
Theyareavailablewithabsoluteordifferentialcoilsinbothbridgeandrefectionconfgurations(shieldedandunshielded).
Shieldedcoilshaveaneffectivesensitiveareaofapproximately.08(mm)indiameter.
Cablessoldseparately.
For bridge probes use cables C/SC/6 (P/N 911016) or C/RA/6 (P/N 911017). For reflection probes use cables CR/SC/6
(P/N91149)orCR/RA/6(P/N91140).TheaboveprobeshaveastandardO.D.=0.18,*Probediameter=0.5
frequency range absolute unshielded Part number absolute Shielded Part number
Detachable absolute (bridge type )
50Khz-100Khz P/50Khz-100Khz/AU 91401 P/50Khz-100Khz/A 91407
100Khz-500Khz P/100Khz-500Khz/AU 9140 P/100Khz-500Khz/A 91408
500Khz-1Mhz P/500Khz-1Mhz/AU 9140 P/500Khz-1Mhz/A 91014
1Mhz-Mhz P/1Mhz-Mhz/AU 91404 P/1Mhz-Mhz/A 91409
Mhz-4Mhz P/Mhz-4Mhz/AU 91405 P/Mhz-4Mhz/A 91410
4Mhz-6Mhz P/4Mhz-6Mhz/AU 91406 P/4Mhz-6Mhz/A 91411
Detachabl
e refection absolute
1Khz-100Khz PR/1Khz-100Khz/AU 91658* PR/1Khz-100Khz/A 91659*
100Khz-1Mhz PR/100Khz-1Mhz/AU 91417 PR/100Khz-1Mhz/A 9140
1Mhz-Mhz PR/1Mhz-Mhz/AU 91418 PR/1Mhz-Mhz/A 9141
frequency range Differential unshielded Part number Differential Shielded Part number
Detachable Differential (bridge type)
500Khz-Mhz P/500Khz-Mhz/DU 9141 P/500Khz-Mhz/D 91015
Mhz-4Mhz P/Mhz-4Mhz/DU 9141 P/Mhz-4Mhz/D 91415
4Mhz-6Mhz P/4Mhz-6Mhz/DU 91414 P/4Mhz-6Mhz/D 91416
Detachable refection Differential
500Khz-Mhz PR/500Khz-Mhz/DU 914 PR/500Khz-Mhz/D 9145
Mhz-6Mhz PR/Mhz-6Mhz/DU 9144 PR/Mhz-6Mhz/D 9146
nortecsonic@olympusNDTcom 1

Nortec

PowerLink Detachable Pencil Probes


How to Order:ProvidePartNumberandDescription
example: 9222180 Pl /100kHz-500kHz/ a
PartNumber Pencil FrequencyRange Absolute
(PRLifRefection) (DifDifferential)
Detachable Pencil Probes
NORTEC

POwERLINK DETaCHaBLE PENCIL PROBES


The Nortec

PowerLink detachable pencil probes are supplied with an adjustable collar and a high quality quick release
connector.
Theyareavailablewithabsoluteordifferentialcoilsinbothbridgeandrefectionconfgurations(shieldedandunshielded).
Shieldedcoilshaveaneffectivesensitiveareaofapproximately0.08(mm)indiameter.
Cablessoldseparately.
frequency range absolute unshielded Part number absolute Shielded Part number
Detachable absolute (bridge type )
50Khz-100Khz PL/50Khz-100Khz/AU 9411 PL/50Khz-100Khz/A 9179
100Khz-500Khz PL/100Khz-500Khz/AU 941 PL/100Khz-500Khz/A 9180
500Khz-1Mhz PL/500Khz-1Mhz/AU 941 PL/500Khz-1Mhz/A 916
1Mhz-Mhz PL/1Mhz-Mhz/AU 9414 PL/1Mhz-Mhz/A 9181
Mhz-4Mhz PL/Mhz-4Mhz/AU 9415 PL/Mhz-4Mhz/A 9416
4Mhz-6Mhz PL/4Mhz-6Mhz/AU 9417 PL/4Mhz-6Mhz/A 9418
Detachable refection absolute
1Khz-100Khz PRL/1Khz-100Khz/AU 9419* PRL/1Khz-100Khz/A 940*
100Khz-1Mhz PRL/100Khz-1Mhz/AU 941 PRL/100Khz-1Mhz/A 9188
1Mhz-Mhz PRL/1Mhz-Mhz/AU 94 PRL/1Mhz-Mhz/A 94
frequency range Differential unshielded Part number Differential Shielded Part number
Detachable Differential (bridge type)
500Khz-Mhz PL/500Khz-Mhz/DU 946 PL/500Khz-Mhz/D 9184
Mhz-4Mhz PL/Mhz-4Mhz/DU 947 PL/Mhz-4Mhz/D 9185
4Mhz-6Mhz PL/4Mhz-6Mhz/DU 948 PL/4Mhz-6Mhz/D 9186
Detachable refection Differential
500Khz-Mhz PRL/500Khz-Mhz/DU 940 PRL/500Khz-Mhz/D 916
Mhz-6Mhz PRL/Mhz-6Mhz/DU 941 PRL/Mhz-6Mhz/D 94
wwwolympusNDTcom
Detachable Pencil Probes
NORTEC

STaNDaRD DETaCHaBLE mETaL SHaFT PENCIL PROBES


Thesegeneralpurposeprobesareusedforsurfaceornearsurfacecrackdetection.Theyarealsousedforconductivityandcoating
thicknessmeasurements.Theyareavailablewithabsolutecoilsinthebridgeconfguration(shielded,unshieldedandrefection
shielded).Referencecoilsareinternal,insuringthebestmatchtothetestcoilwithoutanexternaladapter.Theseprobesinclude
ahighqualityquickreleaseconnector.
Cablessoldseparately.
Nortec

Standard Detachable metal Shaft Probe


How to Order:ProvidePartNumberandDescription
example:9222180 P /100kHz-500kHz/ a /90 .5 /6
PartNumber Pencil FrequencyRange Absolute Angleattip Dropattip TotalLength
(PRifRefection) (DifDifferential)
ForbridgeprobesusecablesC/SC/6(P/N911016)orC/RA/6(P/N911017).ForrefectionprobesusecablesCR/SC/6(P/N91149)
orCR/RA/6(P/N91140).Otherangles,dropsandlengthsavailable.
4OTAL,ENGTH
$ROP
Frequency Range Absolute Shielded Part Number Refection Absolute Shielded Part Number
Straight Shaft
50Khz-100Khz P/50Khz-100Khz/A/0.0/4 916190 PR/50Khz-500Khz/A/0.0/4 916194
100Khz-500Khz P/100Khz-500Khz/A/0.0/4 916191
500Khz-1Mhz P/500Khz-1Mhz/A/0.0/4 91619 PR/500Khz-Mhz/A/0.0/4 916195
1Mhz-Mhz P/1Mhz-Mhz/A/0.0/4 91619
Right Angle Shaft 0.03 Drop
50Khz-100Khz P/50Khz-100Khz/A/90.0/6 91600 PR/50Khz-500Khz/A/90.0/6 91604
100Khz-500Khz P/100Khz-500Khz/90.0/6 91601
500Khz-1Mhz P/500Khz-1Mhz/A/90.0/6 9160 PR/500Khz-Mhz/A/90.0/6 91605
1Mhz-Mhz P/1Mhz-Mhz/A/90.0/6 9160
Right Angle Shaft 0.25 Drop
50Khz-100Khz P/50Khz-100Khz/A/90.5/6 91610 PR/50Khz-500Khz/A/90.5/6 91614
100Khz-500Khz P/100Khz-500Khz/90.5/6 91611
500Khz-1Mhz P/500Khz-1Mhz/A/90.5/6 9161 PR/500Khz-Mhz/A/90.5/6 91615
1Mhz-Mhz P/1Mhz-Mhz/A/90.5/6 9161
Right Angle Shaft 0.50 Drop
50Khz-100Khz P/50Khz-100Khz/A/90.5/6 9160 PR/50Khz-500Khz/A/90.5/6 916
100Khz-500Khz P/100Khz-500Khz/90.5/6 9101
500Khz-1Mhz P/500Khz-1Mhz/A/90.5/6 9161 PR/500Khz-Mhz/A/90.5/6 9164
1Mhz-Mhz P/1Mhz-Mhz/A/90.5/6 916
nortecsonic@olympusNDTcom
Nortec

PowerLink

Detachable metal Shaft Probes


How to Order:ProvidePartNumberandDescription
example: 9222180 ml /100kHz-500kHz/ a /90 .5 /6
PartNumber ML=Bridge FrequencyRange Absolute Angleattip Dropattip TotalLength
MRL=Refection
4OTAL,ENGTH
$ROP
Detachable Pencil Probes
NORTEC

POwERLINK DETaCHaBLE mETaL SHaFT PENCIL PROBES


PowerLinkMetalShaftprobesareusedforsurfaceornearsurfacecrackdetection.Theyarealsousedforconductivityand
coatingthicknessmeasurements.Theyareavailablewithabsolutecoilsinthebridgeconfguration(shielded,unshieldedand
refectionshielded).Referencecoilsareinternal,insuringthebestmatchtothetestcoilwithoutanexternaladapter.Common
cablecompatibilityamongmostPowerLinkeddycurrentprobesallowsonecabletooperateprobesineitherbridgeorrefection
confguration.AllNortec

PowerLinkeddycurrentprobesarebackwardcompatibletoNortec

NDT-19andNDT-4instruments.
CablesCL/SC/6forNortec000seriesandC/SC/67PforNDT-19andNDT-4instruments,aresoldseperately.
ProbesuseCL/SC/6cable(P/N9108).Otherangles,dropsandlengthsavailable.
Frequency Range Absolute Shielded Part Number Refection Absolute Shielded Part Number
Straight Shaft
50Khz-100Khz ML/50Khz-100Khz/A/0.0/4 9165 MRL/50Khz-500Khz/A/0.0/4 909
100Khz-500Khz ML/100Khz-500Khz/A/0.0/4 90
500Khz-1Mhz ML/500Khz-1Mhz/A/0.0/4 90 MRL/500Khz-Mhz/A/0.0/4 910
1Mhz-Mhz ML/1Mhz-Mhz/A/0.0/4 947
Right Angle Shaft 0.03 Drop
50Khz-100Khz ML/50Khz-100Khz/A/90.0/6 947 MRL/50Khz-500Khz/A/90.0/6 9477
100Khz-500Khz ML/100Khz-500Khz/90.0/6 904
500Khz-1Mhz ML/500Khz-1Mhz/A/90.0/6 905 MRL/500Khz-Mhz/A/90.0/6 9478
1Mhz-Mhz ML/1Mhz-Mhz/A/90.0/6 900
Right Angle Shaft 0.25 Drop
50Khz-100Khz ML/50Khz-100Khz/A/90.5/6 9474 MRL/50Khz-500Khz/A/90.5/6 91
100Khz-500Khz ML/100Khz-500Khz/90.5/6 906
500Khz-1Mhz ML/500Khz-1Mhz/A/90.5/6 907 MRL/500Khz-Mhz/A/90.5/6 914
1Mhz-Mhz ML/1Mhz-Mhz/A/90.5/6 90004
Right Angle Shaft 0.50 Drop
50Khz-100Khz ML/50Khz-100Khz/A/90.5/6 9476 MRL/50Khz-500Khz/A/90.5/6 915
100Khz-500Khz ML/100Khz-500Khz/90.5/6 9164
500Khz-1Mhz ML/500Khz-1Mhz/A/90.5/6 908 MRL/500Khz-Mhz/A/90.5/6 916
1Mhz-Mhz ML/1Mhz-Mhz/A/90.5/6 90071
4 wwwolympusNDTcom
Detachable Surface Probes
NORTEC

STaNDaRD DETaCHaBLE SuRFaCE PROBES


Detachablesurfaceprobesareavailableinavarietyofdiametersandfrequencyranges.Theyareshieldedtoprovide
maximumsensitivityandareusedforcrackdetection,thicknessmeasurement,conductivity,andcoatingthickness
measurements.Theseprobesincludeahighqualityquickreleaseconnector.Cablessoldseparately.
Nortec

Standard Detachable Surface Probes


How to Order:ProvidePartNumberandDescription
example: 9213012 S /1kHz-50kHz /.31
PartNumber Surface FrequencyRange Diameter
(SRifRefection)
ForbridgeprobesusecablesC/SC/6(P/N911016)orC/RA/6(P/N911017).
ForrefectionprobesusecablesCR/SC/6(P/N91149)orCR/RA/6(P/N91140).
Standard bridge
Frequency Range Diameter Description
Eqivalent to Non-Detachable
SPO Probe
Part Number
100Hz-Khz .75 S/100Hz-Khz/.75 91549
00Hz-10Khz .6 S/00Hz-10Khz/.6 SPO-565,SPO-115 91011
400Hz-0Khz .50 S/400Hz-0Khz/.50 SPO-565A 91548
500Hz-40Khz .44 S/500Hz-40Khz/.44 SPO-140,SPO-191 91547
1Khz-50Khz .1 S/1Khz-50Khz/.1 SPO-184,SPO-1598 9101
5Khz-100Khz .5 S/5Khz-100Khz/.5 SPO-1 91546
100Khz-500Khz .5 S/100Khz-500Khz/.5 916541
Standard Refection
Frequency Range Diameter Description
Eqivalent to Non-Detachable
Alcoprobe & SPO Probes
Part Number
100Hz-5Khz .75 SR/100Hz-5Khz/.75 APS/0/S 91555
100Hz-0Khz .6 SR/100Hz-0Khz/.6 APG/16/S,SPO-14 91554
00Hz-40Khz .50 SR/00Hz-40Khz/.50 APB/1.5/S,SPO-16 9155
400Hz-60Khz .44 SR/400Hz-60Khz/.44 APBK/10.5/S,SPO-05 9155
700Hz-80Khz .1 SR/700Hz-80Khz/.1 APR/8/S,SPO-06 91551
Khz-00Khz .5 SR/Khz-00Khz/.5 APR/7/S,SPO-404 91550
nortecsonic@olympusNDTcom 5
Nortec

PowerLink Detachable Surface Probes


How to Order:ProvidePartNumberandDescription
example: 9222161 Sl /1kHz-50kHz /.31
PartNumber Surface FrequencyRange Diameter
(SRLifRefection)
ProbesuseCL/SC/6cable(P/N9108).
NORTEC

POwERLINK DETaCHaBLE SuRFaCE PROBES


Detachablesurfaceprobesareavailableinavarietyofdiametersandfrequencyranges.Theyareshieldedtoprovidemaximum
sensitivity and are used for crack detection, thickness measurement, conductivity and coating thickness measurements.
Common cable compatibility among most PowerLink eddy current probes allows one cable to operate probes in either
bridgeorrefectionconfguration.AllNortec

PowerLinkeddycurrentprobesarebackwardcompatibletoNortec

NDT-19
andNDT-4instruments.CablesCL/SC/6forNortec000seriesandC/SC/67PforNDT-19andNDT-4instruments,are
soldseperately.
Detachable Surface Probes
Standard Bridge
Frequency Range Diameter Description
Eqivalent to Non-Detachable
SPO Probe
Part Number
100Hz-Khz .75 SL/100Hz-Khz/.75 919
00Hz-10Khz .6 SL/00Hz-10Khz/.6 SPO-565,SPO-115 919
100Khz-500Khz .6 SL/100Khz-500Khz/.6 98
400Hz-0Khz .50 SL/400Hz-0Khz/.50 SPO-565A 9457
500Hz-40Khz .44 SL/500Hz-40Khz/.44 SPO-140,SPO-191 9456
1Khz-50Khz .1 SL/1Khz-50Khz/.1 SPO-184,SPO-1598 9161
5Khz-100Khz .5 SL/5Khz-100Khz/.5 SPO-1 9196
100Khz-500Khz .5 SL/100Khz-500Khz/.5 908
Standard Refection
Frequency Range Diameter Description
Eqivalent to Non-Detachable
Alcoprobe & SPO Probes
Part Number
100Hz-5Khz .75 SRL/100Hz-5Khz/.75 APS/0/S 9458
100Hz-0Khz .6 SRL/100Hz-0Khz/.6 APG/16/S,SPO-14 9160
00Hz-40Khz .50 SRL/00Hz-40Khz/.50 APB/1.5/S,SPO-16 9198
400Hz-60Khz .44 SRL/400Hz-60Khz/.44 APBK/10.5/S,SPO-05 9199
700Hz-80Khz .1 SRL/700Hz-80Khz/.1 APR/8/S,SPO-06 900
Khz-00Khz .5 SRL/Khz-00Khz/.5 APR/7/S,SPO-404 901
6 wwwolympusNDTcom
Nortec

Standard Ring/Donut Probes


How to Order:ProvidePartNumberandDescription
example: 9203307 SPo-996 ring/Donut Probe
PartNumber SPONumber
Ring/Donut Probes
I.D.
O.D.
NORTEC

STaNDaRD RING/DONuT PROBES (SPO SERIES)


Ring/Donut(encircling)probesaremadetoftvariousfastenerheaddiameters.Theyaremostlyusedforsubsurfacecrack
detectionwiththefastenerinplace.Theseprobesaresuppliedwithabuilt-insmalldiameterlownoisecable.Theyareavailable
inbothbridgeorrefectionconfgurations.
ProbeswillbesuppliedwithNortec8pinBurndyconnectorunlessotherwisespecifed.Othersizesandfrequenciesareavailable
tomeetspecifcrequirements.ContacttheSensorsdepartmentatStaveleyInstrumentsformoredetails.
*Probesintwohalvesforlimitedaccessarea.
Bridge Ring/Donut Probes Refection Ring/Donut Probes
Frequency
Range
I.D. O.D. Description Part # Frequency Range I.D. O.D. Description Part #
500Hz-5Khz .0 .75 SPO-996 9007 100Hz-10Khz .0 .80 SPO-01 91670
100Hz-1Khz . .8 SPO-1589 914019 100Hz-10Khz .40 .80 SPO-11 91670
100Hz-1Khz . 1.00 SPO-1747 91400 100Hz-10Khz .50 1.5 SPO-00 916704
100Hz-1Khz .4 1.00 SPO-71 90950 100Hz-10Khz .54 .88 SPO-44 916705
100Hz-1Khz .8 1.00 SPO-1746 91401 100Hz-10Khz .54 1.15 SPO-4 916706
00Hz-1Khz .40 .80 SPO-1074 904788* 100Hz-10Khz .6 1.40 SPO-0 916707
00Hz-1Khz .4 .80 SPO-5 9140 100Hz-10Khz .6 1.56 SPO-4 916708
100Hz-1Khz .46 1.00 SPO-1745 91404 100Hz-10Khz .80 1.40 SPO-064 916709
100Hz-1Khz .50 1.00 SPO-7 91405 100Hz-10Khz .87 1.40 SPO-45 916710
100Hz-1Khz .50 1.5 SPO-78 90951
100Hz-1Khz .56 1.15 SPO-1744 91406
100Hz-1Khz .6 1.1 SPO-140 91400*
100Hz-1Khz .6 1.40 SPO-1154 90955
100Hz-1Khz .64 1.15 SPO-174 91407
100Hz-1Khz .65 1.40 SPO-89 91408
100Hz-1Khz .75 1.40 SPO-18 9094
100Hz-1Khz .80 1.40 SPO-174 90956
100Hz-1Khz .87 1.40 SPO-5 91409
nortecsonic@olympusNDTcom 7
Nortec

PowerLink Ring/Donut Probes


How to Order:ProvidePartNumberandDescription
example: 9230154 SPo-996l ring/Donut Probe
PartNumber SPONumber
Ring/Donut Probes
NORTEC

POwERLINK RING/ DONuT PROBES (SPO SERIES)


Ring/Donut(encircling)probesaremadetoftvariousfastenerheaddiameters.Theyaremostlyusedforsubsurfacecrack
detectionwiththefastenerinplace.Theseprobesaresuppliedwithabuilt-insmalllownoisecable.Theyareavailableinboth
bridgeorrefectionconfgurations.
Probeswillbesuppliedwitha16pinLemoconnector.Othersizesandfrequenciesareavailabletomeetspecifcrequirements.
ContacttheSensorsdepartmentatStaveleyInstrumentsformoredetails.
I.D.
O.D.
*Probesintwohalvesforlimitedaccessarea.
Bridge Ring/Donut Probes Refection Ring/Donut Probes
Frequency Range I.D. O.D. Description Part # Frequency Range I.D. O.D. Description Part #
500Hz-5Khz .0 .75 SPO-996L 90154 100Hz-10Khz .0 .80 SPO-01L 90076
100Hz-1Khz . .8 SPO-1589L 9015 100Hz-10Khz .40 .80 SPO-11L 90
100Hz-1Khz . 1.00 SPO-1747L 9016 100Hz-10Khz .50 1.5 SPO-00L 90
100Hz-1Khz .4 1.00 SPO-71L 9017 100Hz-10Khz .54 .88 SPO-44L 904
100Hz-1Khz .8 1.00 SPO-1746L 9018 100Hz-10Khz .54 1.15 SPO-4L 905
00Hz-1Khz .40 .80 SPO-1074L 9019* 100Hz-10Khz .6 1.40 SPO-0L 906
00Hz-1Khz .4 .80 SPO-5L 900 100Hz-10Khz .6 1.56 SPO-4L 907
100Hz-1Khz .46 1.00 SPO-1745L 901 100Hz-10Khz .80 1.40 SPO-064L 908
100Hz-1Khz .50 1.00 SPO-7L 90 100Hz-10Khz .87 1.40 SPO-45L 909
100Hz-1Khz .50 1.5 SPO-78L 90
100Hz-1Khz .56 1.15 SPO-1744L 904
100Hz-1Khz .6 1.1 SPO-140L 905*
100Hz-1Khz .6 1.40 SPO-1154L 906
100Hz-1Khz .64 1.15 SPO-174L 907
100Hz-1Khz .65 1.40 SPO-89L 908
100Hz-1Khz .75 1.40 SPO-18L 909
100Hz-1Khz .80 1.40 SPO-174L 900
100Hz-1Khz .87 1.40 SPO-5L 901
8 wwwolympusNDTcom
NORTEC

DETaCHaBLE RING/ DONuT PROBES


Ring/ Donut (encircling) probes are made to ft
various fastener head diameters.They are mostly
usedforsubsurfacecrackdetectionwiththefastener
in place. They are available in both bridge or
refectionconfgurations.
Theseprobesincludeahighqualityquickrelease
connector.Cablessoldseparately.
Ring/Donut Probes
Nortec

Detachable Ring/Donut Probes


How to Order:ProvidePartNumberandDescription
example: 9215653 r /100Hz - 1kHz /.50 1.00
PartNumber Surface FrequencyRange InternalDiameter ExternalDiameter
(RRifrefection)
ForbridgeprobesusecablesC/SC/6(P/N911016)orC/RA/6(P/N911017).
ForrefectionprobesusecablesCR/SC/6(P/N91149)orCR/RA/6(P/N91140).
Bridge Ring/Donut Probes
Frequency Range I.D. O.D. Description Part # Equivalent to Non-Detachable SPO Probes
500Hz-5Khz .0 .75 R/500Hz-5Khz/.0-.75 915650 SPO-996
100Hz-1Khz . 1.00 R/100Hz-1Khz/.-1.00 915651 SPO-1747
100Hz-1Khz .4 1.00 R/100Hz-1Khz/.4-1.00 91565 SPO-71
100Hz-1Khz .50 1.00 R/100Hz-1Khz/.50-1.00 91565 SPO-7
100Hz-1Khz .50 1.5 R/100Hz-1Khz/.50-1.15 915654 SPO-78
00Hz-1Khz .56 1.15 R/100Hz-1Khz/.56-1.15 915655 SPO-1744
00Hz-1Khz .6 1.40 R/100Hz-1Khz/.6-1.40 915656 SPO-1154
100Hz-1Khz .75 1.40 R/100Hz-1Khz/.75-1.40 915657 SPO-18
100Hz-1Khz .80 1.40 R/100Hz-1Khz/.80-1.40 915658 SPO-174
Refection Ring/Donut Probes
Frequency Range I.D. O.D. Description Part # Equivalent to Alcoprobe or SPO Probes
100Hz-10Khz .0 .80 RR/100Hz-10Khz/.0-.80 915659 ARP/8/PSPO-01
100Hz-10Khz .40 .80 RR/100Hz-10Khz/.40-.80 915660 ARP/9.5/PSPO-11
100Hz-10Khz .50 1.5 RR/100Hz-10Khz/.50-1.5 915661 ARP/1.5/1PSPO-00
100Hz-10Khz .54 .88 RR/100Hz-10Khz/.54-.88 91566 ARP/1.5/4PSPO-44
100Hz-10Khz .54 1.15 RR/100Hz-10Khz/.54-1.15 91566 ARP/1.5/9PSPO-4
100Hz-5Khz .6 1.40 RR/100Hz-5Khz/.6-1.40 915664 ARP/16/6PSPO-0
100Hz-5Khz .6 1.56 RR/100Hz-5Khz/.6-1.56 915665 ARP/16/40PSPO-
100Hz-5Khz .80 1.40 RR/100Hz-5Khz/.80-1.40 915666 ARP/0/6PSPO-064
100Hz-5Khz .87 1.40 RR/100Hz-5Khz/.87-1.40 915667 ARP//6PSPO-45
)$
/$
nortecsonic@olympusNDTcom 9
NORTEC

POwERLINK DETaCHaBLE RING/ DONuT PROBES


Ring/ Donut (encircling) probes are made to fit
variousfastenerheaddiameters.Theyareusedmostly
for subsurface crack detection with the fastener in
place.Theyareavailableinbothbridgeorrefection
confgurations.Commoncablecompatibilityamong
most PowerLink eddy current probes allows one
cabletooperateprobesineitherbridgeorrefection
confguration.AllNortec

PowerLinkeddycurrent
probesarebackwardcompatiblewithNortec

NDT-
19 and NDT-4 instruments. Cables CL/SC/6 for
Nortec

000seriesandC/SC/67PforNDT-19and
NDT-4instruments,aresoldseperately.
Nortec

Detachable PowerLink Ring/Donut Probes


How to Order:ProvidePartNumberandDescription
example: 9222233 rl /500Hz - 5kHz /.30- .75
PartNumber Surface FrequencyRange InternalDiameter ExternalDiameter
(RRLifrefection)
Ring/Donut Probes
)$
/$
Other sizes and frequencies are available to meet specific requirements. Contact the Sensors department at Staveley Instruments
formoredetails.ProbesuseCL/SC/6cable(9108).
Bridge Ring/Donut Probes
Frequency Range I.D. O.D. Description Part # Equivalent to Non-Detachable SPO Probes
500Hz-5Khz .0 .75 RL/500Hz-5Khz/.0-.75 9 SPO-996
100Hz-1Khz . 1.00 RL/100Hz-1Khz/.-1.00 9479 SPO-1747
100Hz-1Khz .4 1.00 RL/100Hz-1Khz/.4-1.00 9480 SPO-71
100Hz-1Khz .50 1.00 RL/100Hz-1Khz/.50-1.00 9481 SPO-7
100Hz-1Khz .50 1.5 RL/100Hz-1Khz/.50-1.15 948 SPO-78
00Hz-1Khz .56 1.15 RL/100Hz-1Khz/.56-1.15 948 SPO-1744
00Hz-1Khz .6 1.40 RL/100Hz-1Khz/.6-1.40 9484 SPO-1154
100Hz-1Khz .75 1.40 RL/100Hz-1Khz/.75-1.40 9485 SPO-18
100Hz-1Khz .80 1.40 RL/100Hz-1Khz/.80-1.40 9486 SPO-174
Refection Ring/Donut Probes
Frequency Range I.D. O.D. Description Part # Equivalent to Alcoprobe or SPO Probes
100Hz-10Khz .0 .80 RRL/100Hz-10Khz/.0-.80 97 ARP/8/PSPO-01
100Hz-10Khz .40 .80 RRL/100Hz-10Khz/.40-.80 9487 ARP/9.5/PSPO-11
100Hz-10Khz .50 1.5 RRL/100Hz-10Khz/.50-1.5 98 ARP/1.5/1PSPO-00
100Hz-10Khz .54 .88 RRL/100Hz-10Khz/.54-.88 9488 ARP/1.5/4PSPO-44
100Hz-10Khz .54 1.15 RRL/100Hz-10Khz/.54-1.15 9489 ARP/1.5/9PSPO-4
100Hz-5Khz .6 1.40 RRL/100Hz-5Khz/.6-1.40 9490 ARP/16/6PSPO-0
100Hz-5Khz .6 1.56 RRL/100Hz-5Khz/.6-1.56 9491 ARP/16/40PSPO-
100Hz-5Khz .80 1.40 RRL/100Hz-5Khz/.80-1.40 949 ARP/0/6PSPO-064
100Hz-5Khz .87 1.40 RRL/100Hz-5Khz/.87-1.40 949 ARP//6PSPO-45
0 wwwolympusNDTcom
Nortec

Standard Sliding Probes


How to Order:ProvidePartNumberandDescription
example: 9215653 SPo-3806
PartNumber Description
Sliding Probes
NORTEC
SPO-3806
NORTEC
SPO-2664
NORTEC
SPO-1958
NORTEC
SPO-1994
Fixed Type Adjustable Type
NORTEC

STaNDaRD SLIDING PROBES


Fixedandadjustabletypesareavailable.Operatingintherefectionmode,theyallowinspectionoffastenerrowsforsurface
andsubsurfacecracks.Slidingprobesaredirectionallysensitiveandfeatureengravedgreenlinestoassistscanorientationtothe
expecteddirectionofthecracks.Fixedtypesaremostlyusedinrivetedjointstodetectcracksemanatingfromholes.Penetration
issuffcientforfuselagethicknessupto0.15(4mm).Adjustabletypesareusedforthickerstructuresupto0.75(19mm).They
operatesatisfactorilywithvariousfastenersincludingmagnetictypes.
Fixed Types
SPO # Part # Frequency Range Cable Type
Probe Size
LxWxH
Application
SPO-10 906409 1Khz-100Khz
Microdot
(Dual)
1.5x0.5x1.0
Forsurfacecracksandsecondlayer
nearsurfacecracks.
SPO-806 91166 1Khz-100Khz
CR/SC/6
(Detachable)
1.5x0.8x1.0
Forsurfaceandsecond
layercracks.
SPO-99 91618 1Khz-100Khz
CR/SC/6
(Detachable)
1.7x1.0x1.
SameasSPO-806but
willacceptlargerfastenerheads.
SPO-664 9060 1Khz-100Khz
CR/SC/6
(Detachable)
1.5x.5x1.0
Forsurfacecracksandsecondlayer
nearsurfacecracks.
Adjustable Types
SPO-1958 906405 100Hz-50Khz
Microdot
(Dual)
1.8x1.0x0.7 Penetrationupto0.5
SPO-1994 906406 100Hz-0Khz
Microdot
(Dual)
.x1.0x0.8 Penetrationupto0.5
SPO-1957 906404 100Hz-10Khz
Microdot
(Dual)
.8x1.x0.9 Penetrationupto0.7
Cables
Cable Part # Description Cable Part # Description
ForMicrodotType 9116184 SPO-18 ForDetachableType 91149 CR/SC/6
ForMicrodotType
(RightAngle)
9116185 SPO-419
ForDetachableType
(RightAngle)
91140 CR/RA/6
nortecsonic@olympusNDTcom 1
Nortec

PowerLink Sliding Probes


How to Order:ProvidePartNumberandDescription
example: 9222242 SPo-3806l
PartNumber Description
NORTEC
SPO-3806
NORTEC
SPO-2664
NORTEC
SPO-1958
NORTEC
SPO-1994
Fixed Type Adjustable Type
NORTEC

POwERLINK SLIDING PROBES


Fixedandadjustabletypesareavailable.Operatingintherefectionmode,theyallowinspectionoffastenerrowsforsurface
andsubsurfacecracks.Slidingprobesaredirectionallysensitiveandfeatureengravedgreenlinestoassistscanorientationtothe
expecteddirectionofthecracks.Fixedtypesaremostlyusedinrivetedjointstodetectcracksemanatingfromholes.Penetration
issuffcientforfuselagethicknessupto0.15(4mm).Adjustabletypesareusedforthickerstructuresupto0.75(19mm).They
operatesatisfactorilywithvariousfastenersincludingmagnetictypes.
Sliding Probes
fixed types
SPo # Part #
frequency
range
cable type Probe Size lxWxH application
SPO-10L 941 1Khz-100Khz
16pinto
Microdot
1.5x0.5x1.0
Forsurfacecracksandsecondlayer
nearsurfacecracks.
SPO-806L 94 1Khz-100Khz CL/SC/6 1.5x0.8x1.0 Forsurfacecrackssecondlayercracks.
SPO-99L 94 1Khz-100Khz CL/SC/6 1.7x1.0x1.
SameasSPO-806but
willacceptlargerfastenerheads.
SPO-664L 90101 1Khz-100Khz CL/SC/6 1.5x.5x1.0
Forsurfacecracksandsecondlayer
nearsurfacecracks.
adjustable types
SPO-1958L 90616 100Hz-50Khz
16pinto
Microdot
1.8x1.0x0.7 Penetrationupto0.5
SPO-1994L 90617 100Hz-0Khz
16pinto
Microdot
.x1.0x0.8 Penetrationupto0.5
SPO-1957L 90618 100Hz-10Khz
16pinto
Microdot
.8x1.x0.9 Penetrationupto0.7
cables
cable Part # Description cable Part # Description
16pintoMicrodot 9074 16pinLemotoDualMicrodot CL/SC/6 9108 16pinLemoto7pinLemo
wwwolympusNDTcom
Nortec

PowerLink Sliding Probes


How to Order:ProvidePartNumber,Type,andFrequency
example: 9202932 3049a 100kHz
PartNumber Type Frequency
Conductivity Probes
NORTEC

STaNDaRD CONDuCTIvITy PROBES


Conduct i vi t y pr obes ar e desi gned f or sor t i ng met al s and
al umi num al l oys , det er mi ni ng heat - t r eat ment condi t i on
or damage. These pr obes wer e devel oped f or Nor t ec
conductivityinstruments.StandardfrequencyoftheprobesfortheNDT-5
and5Ais100KHz(60KHzmanufacturedatcustomerrequest).
These pr obes ar e suppl i ed onl y wi t h connect or s f or t he
instruments specified, and are not interchangeable with other
instruments.
Pr obes r equi r e i ns t r ument t o be cal i br at ed by St avel ey
InstrumentsServiceDepartmentforaccurateoperation.
*HeavyDutyCable
For Use With NDT-5 (8% to 110% IACS)
Part # Probe Frequency Diameter Length
909 049A 100KHZ .75 0mm .75 70mm
9095* 049E 100KHZ .75 0mm .75 70mm
91665 SPO-897 100KHZ .1 8mm .75 70mm
For Use With NDT-5A (26% to 65% IACS)
909 049C 100KHZ .75 0mm .75 70mm
9094* 049D 100KHZ .75 0mm .75 70mm
91664 SPO-887 100KHZ .1 8mm .75 70mm
For Use With NDT-17 (24% to 65% IACS)
906106(1) SPO-460 60KHZ .75 0mm 1.00 6mm
906414() SPO-1688 60KHZ .1 8mm .75 70mm
nortecsonic@olympusNDTcom
Nortec

PowerLink Conductivity Probes


How to Order:ProvidePartNumber,Type,andFrequency
example: 9222340 lt. Wt. conductivity Probe 60kHz
PartNumber Type Frequency
Conductivity Probes
NORTEC

POwERLINK CONDuCTIvITy PROBES


Nortec

PowerLinkconductivityprobesaredesignedtobeusedwithNortec

1700,000,000,andWorkStationinstruments.
Theyaredesignedforsortingmetalsandaluminumalloys,determiningheat-treatmentconditionordamage.
Standardfrequenciesoftheprobesis60Khzand480Khz.
Theseprobesaresuppliedwitha16pinLemoconnectorandarenotinterchangeablewithotherinstruments.
60 kHz Lt. wt. Conductivity Probe
*NotforusewithNortec

000instrument.
For Use With Nortec 1700, 2000, 3000 and WorkStation (8% to 110% IACS)
Part # Description Frequency Diameter Height
940 Lt.Wt.60KhzConductivityProbe 60Khz 0.75 0mm 1.0 6mm
941* Lt.Wt.480KhzConductivityProbe 480Khz 0.75 0mm 1.0 6mm
960 SPO-887L60KhzConductivityProbe 60Khz 0.1 8mm .75 70mm
961* SPO-887L480KhzConductivityProbe 480Khz 0.1 8mm .75 70mm
4 wwwolympusNDTcom
ID Probes
NORTEC

ID PROBES
Theseprobeshaveacircumferentialwoundcoilavailableinthreecoilconfgurationsandtwobodystyles.Probesareavailable
withorwithoutPowerLink

technology.
1.Absolutestyle-thesedetectchangesinconductivityandisusedtocheckforheattreatingandmonitoringwallthickness.
.Differentialstyle-primarilyusedtodetectpits,cracksandinclusionsinsidetubes.
.Switchable-thesecanbeusedineithermode.
Thereisnochargeforcablelengthsupto40.Polyshaftsareincludedonallcablesunlessotherwisespecifed.Duetothewide
varietyofsizesandfrequencies,IDprobesarebuilttocustomerspecifcationswhenordered.
ID PROBE HOuSING STyLES (order using example charts)
Straight Delrin-lowcostallplasticIDprobes,goodforusewithcleantubes.
Stainless Steel-longlastingheavyduty,canbepushedorpulled.
NOTE: Diameters ordered will be the size manufactured without undersizing. Diameter ordered should be approximately
10%smallerthanthetubesinternaldiameter.Standardsizesrangefrom0.80to1.500.Specifyoperatingfrequencywhen
ordering.Anyfrequencyfrom1kHztoMHzcanbemanufactured.Specialsizes*canbebuilt,downto0.100diameter.
*ContacttheSensorsDepartmentatStaveleyInstrumentsformoredetailsandreferencestandardavailability.
Nortec

ID Probes
Straight Delrin
ID/ D/ 5kHz / A/ .500/ 35
ProbeType Delrin Frequency
CoilType:absolute-
(a)Differential-(D)
Switchable-(S)
ProbeDiameter Lengthofpoly-coveredcable
Stainless Steel
ID/ SS/ 5kHz / A/ .500/ 35
ProbeType StainlessSteel Frequency
CoilType:absolute-
(a)Differential-(D)
Switchable-(S)
ProbeDiameter Lengthofpoly-coveredcable
PowerLink Technology Probes
IDL/ SS/ 5kHz / A/ .500/ 35
ProbeType
HousingType:
StainlessSteel
(SS)Delrin(D)
Frequency
CoilType:absolute-
(a)Differential-(D)
Switchable-(S)
ProbeDiameter Lengthofpoly-coveredcable
nortecsonic@olympusNDTcom 5
OD Probes
NORTEC

OD PROBES
Theseprobeshaveencirclingtypecoilstosurroundrodsortubes.ODprobesare
availableinthreedifferentcoilconfgurations.
1.absoute style-Thesedetectchangesinconductivityandarealsousedin
monitoringtheheattreatingprocess.Theabsolutecoilcanalsobeusedto
monitorwallthicknesstodetectthinningintubewalls.
.Differential style-Primarilyusedforpitandcrackdetection.
.Switchable-Thesecanbeusedineithermode.
ODcoilsaremanufacturedwithlongwearingstainlesssteel
faceplates.Standardprobeholesizesrangefrom0.015to1.50.Duetothe
widevarietyofsizesandfrequencies,ODcoilsaremanufacturedtocustomer
specifcationswhenordered.
Nortec

OD Probes
How to Order:ProvideProbeType,Frequency,ProbeDiameter,andCoilType.
example: oD(1) /10kHz /.525 a
ProbeType Frequency ActualProbeDiameter() CoilType:
absolute-(a)
Differential-(D)
Switchable-(S)
(1)ToorderthePowerLinkversionofthisprobeorderasODL
()Theamountofclearanceneededisdictatedbythefrequencyandmaterialtobeinspected.Ifyouareunsureplease
contacttheSensorsDepartmentatStaveleyInstrumentsformoredetails.
Probesaremanufacturedforeasymounting.Probesize,L=.0xW=1.xH=.1.
ThestandardprobesarefttedwithadetachableLemotriaxleconnector.PowerLinkT probeswillbefttedwitha7pinLemo
connector.Cablesaresoldseperately.Forstandardprobes(Lemotriaxial)usethestandarddetachablecableC/SC/6
(P/N911016).
ForPowerLink probesusethedetachablecableCL/SC/6(P/N9108).
6 wwwolympusNDTcom
GENERaL PuRPOSE KITS
The Nortec

probe kits contain fve of our most widely used probes,


analuminumcrackstandardandablockofsixconductivitysamples.
Thekitsareavailableineitherthestandardprobeserieswithintegral
6cableswith8pinBurndyconnectors,orthedetachableserieswith
aC/SC/6cableincluded(8pinBurndy)
DETaCHaBLE TRaINING KIT
Thiskitcontainstwosurfaceprobes(coveringawidefrequencyrange),
two pencil and two bolt hole probes (absolute and differential), one
right angle pencil probe, two detachable bridge cables (straight and
rightangle),andoneSPO-806slidingrefectionprobewithcable.Also
includedareasetofplasticshimstocks,analuminumcrackstandard,
a thinning standard, a second layer crack standard, aTB-16 hole
standard,andonesetofsixconductivitysamples.Thiskitisavailable
withDetachableProbesonly.
General Purpose Probe Kits
Nortec

Probe Kits
How to Order:ProvidePartNumberandDescription
example: 9216632 Standard Probe kit
PartNumber Description
Standard Probe kit -Stock P/n 9216632 Detachable training kit -Stock P/n 9216655
1)904899 SP-10A10KHzSurfaceProbe 1)91011 S/00KHz-10KHz/.6SurfaceProbe
1)90490 SP-100100KHzSurfaceProbe 1)9101 S/1KHz-50KHz/.1SurfaceProbe
1)904905 SP-500500KHzSurfaceProbe 1)9101 P/100KHz-500KHz/A/90.5/6RightAnglePencilProbe
1)904915 551F500KHzPencilProbe 1)91014 P/500KHz-1MHz/APencilProbe
1)9148 551DFMHzPencilProbe 1)91015 P/500KHz-MHz-DPencilProbe
1)190474 SetofSixConductivitySamples 1)911016 C/SC/66?CableStraightConnector
1)190510 TB-SIAluminumCrackStandard 1)190474 SetofSixConductivitySamples
CarryingCase 1)190510 TB-SIAluminumCrackStandard
Detachable Probe kit -Stock P/n 9216633 1)519540 SetofPlasticShims
1)91011 S/00KHz-10KHz/.6SurfaceProbe 1)190477 TB-16HoleStandard
1)9101 S/1KHz-50KHz/.1SurfaceProbe 1)916156 B/100KHz-500KHz/A.50BoltHoleProbe
1)9101
P/100KHz-500KHz/A/90.5/6Right
AnglePencilprobe
1)1916915
SPO-9SecondLayerCrackStandard
(1/16on1/16Aluminumw/fasteners)
1)91014 P/500KHz-1MHz/APencilProbe 1)916171 B/500KHz-MHz/D.50BoltHoleProbe
1)91015 P/500KHz-MHz/DPencilProbe 1)911017 C/RA/66CableRightAngleConnector
1)911016 C/SC/66CableStraightConnector 1)91166 SPO-806SlidingProbe
1)190474 SetofSixConductivitySamples 1)1916914 SPO-404ThinningSample.09to.164
1)190510 TB-S1AluminumCrackStandard CarryingCase
CarryingCase
nortecsonic@olympusNDT.com
Olympus NDT
TECHNICAL
DATA SHEET
Calibration Screen
Frequency
Horiz Gain
Vert Gain
Phase Angle
LO Filter
HI Filter
Horiz
Vert
Display Mode
Probe Drive
Continuous Sweep Mode
100 KHZ
65.0 dB
65.0 dB
24.0
100
OFF
67.5%
50.0%
MID
OFF
SINGLE
INSTRUMENT SETTINGS
CALIBRATION INFORMATION
Instrument
Instrument Serial
Production Order
Probe Model No.
Probe Serial No.
Probe Part No.
Probe Frequency
Test Standard
Notch Size
Comments:
NORTEC WORKSTATION
NM00G051042
M27515/1
ML/100KHZ-500KHZ/A/90.5/6
J06830
9222164
100KHZ
.040
TB-S1
Instrument Part No. 8500025.02
Technician
QA
Date & Time Tested 10/7/2003 2:26:48 PM
Date
Date
PROBE TEST DATA
Documentation
Probe DocumeNTaTioN
A Test Documentation Form is supplied with all standard Eddy Current Probes. Each probe is tested on a sample or standard
relevant to the probe diameter and frequency, for proper signal response. In addition a Certifcate of Conformance is available
upon request.
Printed 9/2006
2006 Olympus NDT, All Rights Reserved.
*All specifcations are subject to change without notice.
Olympus and the Olympus logo are registered trademarks of Olympus Corporation.
Innovation in NDT is a trademark if Olympus NDT Corporation.
Nortec and Sonic are trademarks of Staveley Instruments Inc.
Other company or product names mentioned in this document may be trademarks or registered
trademarks of their respective companies.
www.olympusNDT.com
Tel: 509-736-2751
Fax: 509-735-4672
E-mail: nortecsonic@olympusNDT.com

Das könnte Ihnen auch gefallen