GENERAL CATALOGUE 2005

PEDROLLO S.p.A. Via Enrico Fermi 7 - P.O. BOX 58 37047 San Bonifacio (Verona) ITALY paid-up capital 30.000.000 Tel. +39 045 6136311 Fax +39 045 7614663 e-mail: sales@pedrollo.com www.pedrollo.com

Pedrollos aim is to move water all over the world, with creativeness and passion. Our pumps are suitable for all purposes, easy to use, ecological, accessible to everyone, everywhere. Our mission is to make water available everywhere, supporting life, development and comfort.

Organized on an area of 70,000 m2 our company makes use of a production process characterised by a high level of technology and automation, putting it at the top of its sector both for the amount of investments and for the ability to ensure quality throughout the production process. Pedrollo pumps are distributed in 160 countries, thus allowing our company to assume an international role that results in a yearly production of close to 2,000,000 units. The range comprises more than 60 families of pumps (drainage pumps, submerged and surface pumps) covering the majority of applications in the domestic, civil, agricultural and industrial sectors.

A highly advanced research and development centre, endowed with the most sophisticated work tools, both hardware and software, allows the continuous updating of the existing range as well as the planning of new products using materials of the latest generation.

The heart of the pump is certainly the electric motor. It is therefore necessary to guarantee not only the best quality of the components used, but also that the execution of the various passages of the winding (insulation, coils, impregnation, etc.) is carried out using the most advanced automatic machines, to guarantee the precision and constancy of the various steps.

Before obtaining approval for the production phase, a technologically advanced test room, equipped with the latest test benches, allows strict electrical and hydraulic testing to ensure the quality and effectiveness of the design phase.

The final assembly of our pumps is carried out on automatic lines which guarantee maximum precision in the assembly phase and a high speed of execution, to ensure that the finished product is available in a short time.

1979 - GOLD MEDAL:


Awarded by the Verona Chamber of Commerce for having achieved a top level on the technical and commercial plain, in both the national and international field.

1993 - MARCO POLO Prize:


Awarded by the Foreign Trade section of the Chamber of Commerce of the Veneto as the best firm, having distinguished itself in 1992 for its economic growth in the international field.

1994 - GOLD MEDAL:


Awarded by the Verona Chamber of Commerce for having carried out considerable technical improvements in the firm.

1995 - COMPANY TO WATCH:


Awarded by the DATABANK as company of the year for the results achieved.

1997 - PUMP TO WATCH:


Awarded by the DATABANK to the TOP submersible pump of the year for its design and advanced technology.

2000 - PUMP TO WATCH:


Awarded by the DATABANK to the 4SR submerged pump of the year for its advanced technological features.

2000 - QUALITY OF LIFE prize:


awarded the entrepreneur and the firm for greater sensitivity to the companys impact on the community and for the ability to integrate the growth of the company with continuous and coherent programmes for the support of culture, art, the environment and the social scene. (Milan - Assolombarda)

2001 - ENTREPRENEUR OF THE YEAR Prize 2001:


awarded, at national level, the entrepreneur and the firm for sensitivity to the social scene and continuous attention to the most needy populations, for the product which responds to the primary needs of man, such as certainly the availability of water. (Milan - Assolombarda)

2002 - ENTERPRISE AND CULTURE Prize:


Prize of the Italian Manufacturers Association, awarded to the project with the highest social value. For efficacy in using culture as a primary resource of social communication and cooperation, in some economically handicapped and problematic countries on the world scene. (Naples - Palazzo Reale)

2002 - CREATIVITY AND INNOVATION Prize:


Awarded by the Association of Industrialists of the province of Verona for having achieved world leadership in the sector of pumps.

2003 - CEREC Prize:


Awarded by the European Committee for the approach to Economy and Culture for the Pedrollo for life project in favour of developing countries, in particular for the recovery of Albanian culture and for commitment in favour of the development of Bangladesh. (Naples - Palazzo Reale)

2004 - DOMUS MERCATORUM Prize:


Awarded by the Verona Chamber of Commerce for the development of new technologies, taking the company to the top world levels in the production of pumps for civil, industrial and agricultural applications.

PERIPHERAL
PK PQ PQ 3000 PQA PV
page 16

VERTICAL

BRONZE
PK PQ CP
page 101 page 102 page 103

VL
page 20

page 118

page 22

VLE

page 122

SUBMERGED
4SK
page 108 page 110

page 24

5SK

page 26

STAINLESS STEEL
AL-RED
page 30

4BLOCK

page 126

CENTRIFUGAL
CP
page 28 page 32

PRO-NGA

SUMO
page 48

page 114

4SR 3-4 CR CP DIN


page 38 page 60

page 130

6SR JCR
page 72

page 144

HF

page 40

TOP MULTI page 112

SELF-PRIMING
NF
page 44

PKS

page 18

SUBMERSIBLE
NGA
page 46

JSW

page 62

TOP

page 156

TOP FLOOR page 158 F


page 82

JDW

page 68

TOP VORTEX page 160 PLURIJET


page 74

MULTI-STAGE
2CP CK RX
page 78 page 162

page 50

3-4CP

page 58

CKR

page 80

RX VORTEX page 164

ZD

page 166

MC

page 188

ZX

page 168

PVXC

page 190

page 170

PMC

page 192

VX

page 172

PORTABLE
BETTY
page 104

BETTYNOX page 107 MC


page 174

HYDROFRESH
VX-I
page 176 page 196

MC-I

page 178

COMBIPRESS
DC
page 180 page 201213

VXC

page 182

MOTORS
MC
page 184

Km1 5690 page 218

VXC

page 186

ACCESSORIES
page 220

pumps with peripheral impeller

RANGE OF PERFORMANCE Flow rate up to 90 l/min (5.4 m3/h) Head up to 100 m LIMITS OF USE Manometric suction lift up to 8 m Liquid temperature up to + 60C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


INSTALLATION AND USE


They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. FOR THEIR RELIABILITY, SIMPLICITY OF USE AND ECONOMY THEY ARE SUITABLE FOR DOMESTIC USE AND IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL PRESSURE SETS, FOR IRRIGATING GARDENS. The pumps must be installed in enclosed places, or at least protected against inclement weather.

PUMP BODY: cast iron, with threaded ports ISO 228/1. MOTOR BRACKET (patent n 1289150): aluminium with brass insert; reduces starting difficulties due to seizure of the impeller after long periods of inactivity. IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. PKm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. PK: three-phase 230/400 V- 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL n 72753. PKm 60 is a REGISTERED TRADE MARK n 602636.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz

16

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PK300

PK200 PK90 PK100

PK80 PK70

Head H (metres)

PK65

PK60

Flow rate Q

TYPE
Single-phase PKm 60 PKm 65 PKm 70 PKm 80 PKm 90 PKm 100 PKm 200 Three-phase PK 60 PK 65 PK 70 PK 80 PK 90 PK 100 PK 200 PK 300

POWER
kW HP

m3/h l/min

0 0

0.3 5 38 50 62 66 82 80 86 95

0.6 10 33.5 45.5 57 61 71 75 81 90

0.9 15 29 40.5 52 56 60 70 76 85

1.2 20 24 36 47 51 49 65 71 80

1.5 25 19.5 31 42 46 38 60 65.5 75

1.8 30 15 27 37 41 27 55 60 70

2.1 35 10 22 32 36.5 17 50 55 65

2.4 40 5 17 27 31 5 45 50 60

3.0 50 8 18 22 35 40 50

3.6 60

4.2 70

4.8 80

5.4 90

0.37 0.50 0.60 0.75 0.75 1.1 1.5 2.2

40 0.50 55 0.70 65 0.85 1 H metres 70 90 1 85 1.5 90 2 100 3

25 30 40

15 20 30

10 20

10

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


f
DN2

h2

DN1

h3

h1

n1 n

TYPE Single-phase Three-phase PKm 60 PK 60 PKm 65 PK 65 PKm 70 PK 70 PKm 80 PK 80 PKm 90 PK 90 PKm 100 PK 100 PKm 200 PK 200 PK 300

PORTS
DN1 DN2

1" 1" 1" 1" 1" 3/4" 1" 1" 1"

1" 1" 1" 1" 1" 3/4" 1" 1" 1"

a 42 48 55 55 55 58 55 55 55

f 243 258/250 285 285 285 288 322 348 342/322 342

h 152 152 152 179 179 179 203 212 203

h1 63 63 63 71 71 71 80 80 80

h2 75 80 85 85 85 95 94 94 94 94

DIMENSIONS mm h3 i m 138 20 80 80 143 20 80 156 20 90 156 156 20 90 20 166 20 90 174 20 100 174 174 20 100 174 20 100

kg n 120 120 120 138 138 138 158 158 158 n1 100 100 100 112 112 112 112 125 125 125 125 w 55 55 55 62 62 62 85 85 95 95 s 7 7 7 7 7 7 9 9 9 1~ 5.3 7.7 10.1 10.3 10.3 10.3 15.0 16.0 3~ 5.3 6.4 9.2 9.9 9.3 13.1 15.2 18.0

17

self-priming pumps with peripheral impeller

RANGE OF PERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 70 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 60C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. FOR THEIR COMPACTNESS, RELIABILITY AND ECONOMY THEY ARE SUITABLE FOR DOMESTIC USE AND IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL PRESSURE SETS, FOR IRRIGATING GARDENS, DRAWING WATER FROM TANKS OR WELLS DOWN TO A DEPTH OF 9 METRES AND IN ALL CASES WHERE THERE IS THE PRESENCE OF AIR OR GAS IN THE LIQUID TO BE PUMPED; the pump is provided with a check flap valve on the intake so that it is no longer necessary to fit a foot valve. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. CHECK FLAP VALVE: incorporated in the suction port. MOTOR BRACKET (patent n 1289150): aluminium with brass insert; reduces starting difficulties due to seizure of the impeller after long periods of inactivity. IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. PKSm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. PKS: three-phase 230/400 V- 50 Hz INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL n 72753.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz

18

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PKS80 PKS70

PKS65

Head H (metres)

PKS60

Flow rate Q

TYPE
Single-phase PKSm 60 PKSm 65 PKSm 70 PKSm 80 Three-phase PKS 60 PKS 65 PKS 70 PKS 80

POWER
kW HP

m3/h l/min

0 0 40 55 65 70

0.3 5 38 50 62 66

0.6 10 33.5 45.5 57 61

0.9 15 29 40.5 52 56

1.2 20 24 36 47 51

1.5 25 19.5 31 42 46

1.8 30 15 27 37 41

2.1 35 10 22 32 36.5

2.4 40 5 17 27 31

2.7 45 12.5 22 27

3.0 50 8 18 22

0.37 0.50 0.60 0.75

0.50 0.70 H metres 0.85 1

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

n f
DN2

k i

h2

DN1

h1

n1

TYPE Single-phase Three-phase PKSm 60 PKS 60 PKSm 65 PKS 65 PKSm 70 PKS 70 PKSm 80 PKS 80

PORTS
DN1 DN2

1" 1" 1" 1" 1"

1" 1" 1" 1" 1"

a f h 29 230 192 192 29 29 238/230 192 29 260 200 200 29 260 200

h1 156 156 156 164 164 164

h2 34 34 34 34 34

DIMENSIONS h3 i 190 110 190 190 110 110 198 110 198 198 110

mm m 80 80 80 90 90 90

h3

kg n 150 150 150 160 160 160 k 120 120 120 138 138 138 n1 100 100 100 112 112 112 w 55 55 55 62 62 62 s 7 7 7 7 7 1~ 6.1 7.7 10.7 10.8 3~ 6.1 7.1 9.6 9.7

19

pumps with peripheral impeller


recommended for industrial uses

RANGE OF PERFORMANCE Flow rate up to 90 l/min (5.4 m3/h) Head up to 100 m LIMITS OF USE Manometric suction lift up to 8 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. THE HYDRAULIC CHARACTERISTICS OF THESE PUMPS, TOGETHER WITH THEIR COMPACTNESS, MAKE THEM SUITABLE FOR USE IN THE INDUSTRIAL SECTOR. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. PUMP BODY: brass for PQ 81-Bs MOTOR BRACKET (patent n 1289150): aluminium with brass insert; reduces starting difficulties due to seizure of the impeller after long periods of inactivity. IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. PQm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. PQ: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL n 72753

OPTIONS ON REQUEST

pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal protection IP 55 other voltages or frequency 60 Hz

20

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PQ300

PQ200 PQ100

PQ80 PQ70

Head H (metres)

PQ65

PQ60

PQ81-81Bs PQ90

Flow rate Q

TYPE
Single-phase PQm 60 PQm 65 PQm 70 PQm 80 PQm 90 PQm 100 PQm 200 Three-phase PQ 60 PQ 65 PQ 70 PQ 80 PQ 90 PQ 100 PQ 200 PQ 300

POWER
kW HP

m3/h l/min

0 0

0.3 5 38 50 62 66 82 80 86 95

0.6 10 33.5 45.5 57 61 71 75 81 90 0.12 2 80 80

0.9 15 29 40.5 52 56 60 70 76 85 0.24 4 71 71

1.2 20 24 36 47 51 49 65 71 80

1.5 25 19.5 31 42 46 38 60 65.5 75

1.8 30 15 27 37 41 27 55 60 70 0.48 8 54 54

2.1 35 10 22 32 36.5 17 50 55 65 0.60 10 45 45

2.4 40 5 17 27 31 5 45 50 60

3.0 50 8 18 22 35 40 50 0.72 12 37 37

3.6 60

4.2 70

4.8 80

5.4 90

0.37 0.50 0.60 0.75 0.75 1.1 1.5 2.2

40 0.50 55 0.70 65 0.85 1 H metres 70 90 1 85 1.5 90 2 100 3 m /h


3

25 30 40 0.84 14 28 28

15 20 30 0.96 16 19 19

10 20

10 1.08 18 10 10

TYPE
Single-phase PQm 81 PQm 81-Bs Three-phase PQ 81 PQ 81-Bs

POWER
kW HP Q

0 0 90 90

0.36 6 63 63

l/min

0.50 0.50

0.70 H metres 0.70

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


f
DN2

h2

DN1

h3

h1

n1 n

TYPE Single-phase Three-phase PQm 60 PQ 60 PQm 65 PQ 65 PQm 70 PQ 70 PQm 80 PQ 80 PQm 81 PQ 81 PQm 81-Bs PQ 81-Bs PQm 90 PQ 90 PQm 100 PQ 100 PQm 200 PQ 200 PQ 300

PORTS
DN1 DN2

1" 1" 1" 1" 1" 1/2" 1/2" 1/2" 3/4" 1" 1" 1" 1"

1" 1" 1" 1" 1" 1/2" 1/2" 1/2" 3/4" 1" 1" 1" 1"

a 22 22 22 22 22 18 18 18 22 25 25 25 25

f 223 234/227 253 253 253 227/220 227/220 227/220 253 292 312/292 318 312

h 152 152 152 179 179 179 152 152 152 179 203 203 212 203

h1 108 113 121 121 121 118 118 118 126 140 140 140 140

h2 30 30 30 30 30 23 23 23 27 30 30 30 30

DIMENSIONS mm h3 i m 138 78 80 78 80 143 78 80 151 83 90 151 83 90 151 83 90 141 71 80 141 71 80 141 71 80 153 84 90 170 89 100 170 89 100 170 100 170 89 100

kg n 120 120 120 138 138 138 120 120 120 138 158 158 158 158 n1 100 100 100 112 112 112 100 100 100 112 125 125 125 w 55 57 62 62 62 58 58 58 62 85 85 85 85 s 7 7 7 7 7 7 7 7 9 9 9 9 1~ 5.3 7.1 9.9 10.0 6.7 6.8 10.0 14.8 15.7 3~ 5.3 6.3 8.9 8.8 6.8 6.8 9.0 14.3 14.8 15.7

21

pump with peripheral impeller


for industrial uses

RANGE OF PERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 180 m LIMITS OF USE Manometric suction lift up to 8 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
It is recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. THE HYDRAULIC CHARACTERISTICS OF THIS PUMP, TOGETHER WITH ITS COMPACTNESS AND STURDINESS, MAKE IT SUITABLE FOR USE IN THE INDUSTRIAL SECTOR. The pump must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: brass with front shim disk in stainless steel. MOTOR BRACKET (patent n 1289150): aluminium with brass and stainless steel insert; eliminates seizure of the impeller after long periods of inactivity. IMPELLER: bronze, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. PQ 3000: three-phase 230/400 V - 50 Hz. INSULATION: class H. PROTECTION: IP 55.

OPTIONS ON REQUEST

pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal other voltages or frequency 60 Hz

22

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PQ3000

Head H (metres)

Flow rate Q

TYPE
Three-phase PQ 3000

POWER
kW HP Q

m3/h l/min

0 0 180

0.6 10 160

0.9 15 145

1.2 20 132

1.5 25 118

1.8 30 105

2.1 35 92

2.4 40 78

2.7 45 63.5

3.0 50 50

2.2

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f
DN2

h2
DN1

h3

s a w m n1 n

TYPE Three-phase

PORTS
DN1 DN2

DIMENSIONS mm a 34 f 329 h 212 h1 142 h2 38 h3 180 i 65 m 100 n 166 n1 125 w 97 s 9

h1

kg 3~ 19.0

PQ 3000

3/4"

3/4"

23

pumps with peripheral impeller


recommended for industrial applications

RANGE OF PERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 90 m LIMITS OF USE Manometric suction lift up to 8 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. NON-FERROUS CONSTRUCTION WITH WETTED PARTS IN HIGH PERFORMANCE TECHNOPOLYMER AND BRASS TO ELIMINATE THE POSSIBILITY OF CORROSION. CONSEQUENTLY THEY ARE RECOMMENDED FOR INDUSTRIAL APPLICATIONS INCLUDING COOLING, CONDITIONING AND BOILER FEED. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS

PUMP BODY: high-performance technopolymer with metal threaded port insert ISO 228-1 for secure pipe connection without damage to the pump body. BODY BACK-PLATE: brass . MOTOR BRACKET (patent n 1289150): aluminium with brass insert; eliminates seizure of the impeller after long periods of inactivity. IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. PQAm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. PQA: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL

OPTIONS ON REQUEST

pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal protection IP 55 other voltages or frequency 60 Hz

24

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PQA90

PQA82 PQA80 PQA72 PQA70

Head H (metres)

PQA60

Flow rate Q

TYPE
Single-phase PQAm 60 PQAm 70 PQAm 72 PQAm 80 PQAm 82 PQAm 90 Three-phase PQA 60 PQA 70 PQA 72 PQA 80 PQA 82 PQA 90

POWER
kW HP

m3/h l/min

0 0 40 65 65 70 70 90

0.1 2 38 62 66 86

0.3 5 35 58 62 62 66 79

0.6 10 29 52 57 56 61 68

0.9 15 23.5 45.5 52 49.5 56 56.5

1.2 20 18 39.5 47 43 51 45.5

1.5 25 12.5 33 42 37 46 34

1.8 30 7 27 37.5 31 41.5 23

1.9 32 5 24 35.5 28 39.5 18.5

2.3 38 16.5 29.5 20.5 37.5 5

2.7 45 8 22.5 12 26.5

3.0 50

0.37 0.55 0.55 0.75 0.75 0.75

0.50 0.75 0.75 H metres 1 1 1

18 22

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f
DN2

h2
DN1

h3

h1

s a w m

n1 n

TYPE Single-phase Three-phase PQAm 60 PQA 60 PQAm 70 PQA 70 PQAm 72 PQA 72 PQAm 80 PQA 80 PQAm 82 PQA 82 PQAm 90 PQA 90

PORTS
DN1 DN2

1/2" 1/2" 1/2" 1" 1/2" 1" 1/2"

1/2" 1/2" 1/2" 1" 1/2" 1" 1/2"

a 25 28 28 28 28 28 27

f 226 258 258 258 258 258 257

h 152 179 179 179 179 179 179

h1 103 116.5 121 116.5 121 121 121

DIMENSIONS mm h2 h3 i 33 136 72.5 72.5 32.5 149 72.5 30 151 83 32.5 149 72.5 30 151 83 35 156 76

kg m 80 90 90 90 90 90 n 120 138 138 138 138 138 138 n1 100 112 112 112 112 112 112 w 55 62 62 62 62 62 s 7 7 7 7 7 7 7 1~ 4.8 10.3 10.4 10.5 10.5 10.4 10.4 3~ 4.8 9.3 9.4 9.5 9.5 9.4 9.4

25

pump with peripheral impeller


recommended for industrial applications

RANGE OF PERFORMANCE Flow rate up to 10 l/min (0.6 m3/h) Head up to 42 m LIMITS OF USE Manometric suction lift up to 8 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. THE CONSTRUCTION OF THIS PARTICULARLY COMPACT BRASS PUMP ELIMINATES THE POSSIBILITY OF RUST AND CORROSION. THIS MAKES IT SUITABLE FOR TRANSFERRING LIQUIDS IN THE MECHANICAL PROCESSING SECTOR, FOR CONTROLLING THE TEMPERATURE OF MOULDS, COOLING, CONDITIONING AND FOR BEVERAGE DISPENSING MACHINES. The pump must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: brass, with threaded ports ISO 228/1. MOTOR BRACKET (patent n 1289150): aluminium with brass insert; eliminates seizure of the impeller after long periods of inactivity. IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - EPDM. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. PVm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. PV: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL

OPTIONS ON REQUEST

pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanikcal seal pump body rotated 90 in anti-clockwise direction protection IP 55 other voltages or frequency 60 Hz

26

CURVES AND PERFORMANCE DATA AT n= 2900 1/min


0 40 0 0.5 0.5 1 1 1.5 1.5 2 2 2.5

120 35

PV55

30

100

25

80

Head H (metres)

20 60

15 40

10
20 5

0
0

1
0.1

3
0.2

5
0.3

6
0.4

8
0.5

10
0.6

Flow rate Q

TYPE
Single-phase PVm 55 Three-phase PV 55

POWER
kW HP

m3/h l/min

0 0 42

0.12 2 35

0.18 3 31

0.24 4 28

0.30 5 25

0.36 6 21.5

0.42 7 18

0.48 8 14.5

0.54 9 11

0.60 10 8

0.18

0.25 Hmetres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

i f
DN1 DN2

h2

h3

s a w m

h1

n1 n

TYPE Single-phase Three-phase

PORTS
DN1 DN2

DIMENSIONS mm a 10 f 203 h 141 h1 56 h2 42 h3 98 i 25 m 72 n 110 n1 90 w 67 s 6 1~ 4.1

kg 3~ 4.1

PVm 55

PV 55

1/4"

1/4"

27

centrifugal pumps

RANGE OF PERFORMANCE Flow rate up to 160 l/min (9.6 m3/h) Head up to 58 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Liquid temperature up to + 40C in the CPX version (with technopolymer impeller) Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. RELIABLE AND MAINTENANCE FREE THEY ARE WIDELY USED IN THE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR FOR WATEER DISTRIBUTION IN COMBINATION WITH SMALL OR MEDIUM PRESSURE SETS, FOR TRANSFER IN GENERAL, FOR IRRIGATING GARDENS. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 304 or cast iron on higher powered models. BRASS IMPELLER: CP 100-CP 132-CP 152-CP 150-CP 170-CP 190-CP 200 STAINLESS STEEL IMPELLER: CP 130-CP 158 MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. CPm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector built into the winding. CP: three-phase230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL n 72753.

OPTIONS ON REQUEST

impeller in technopolymer (CPm...X - CP...X) special mechanical seal other voltages or frequency 60 Hz

28

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

CP200

CP190

Head H (metres)

CP170 CP158 CP152 CP150 CP170M

CP130

CP132A CP132B

CP100

Flow rate Q

TYPE
Single-phase CPm 100 CPm 130 CPm 132B CPm 132A CPm 152 CPm 150 CPm 158 CPm 170 CPm 170M CPm 190 Three-phase CP 100 CP 130 CP 132B CP 132A CP 152 CP 150 CP 158 CP 170 CP 170M CP 190 CP 200

POWER
kW HP

m3/h l/min

0 0 16 23 20 23 33 29.5 36 41 36 50 58

0.6 10 15 22 32 34

1.2 20 14 21 18 22 31 29 33.5

1.8 30 12.5 20 17 21.5 29.5 28.5 33 38 35 46 55

2.4 40 11 19 16 21 28.5 28 32.5 37 34.5 44.5 54.5

3.0

3.6

4.2

4.8

5.4 90

6.0

6.6

7.2

7.8

8.4 140

9.0

9.6

0.25 0.37 0.45 0.60 0.55 0.75 0.75 1.1 1.1 1.5 2.2

0.33 0.50 0.60 0.85 0.75 H metres 1 1 1.5 1.5 2 3

50 60 70 80 9 7 18 17 15.5 14 15 13.5 12 10.5 20 19 18 17 27 25 23 19 27.5 26.5 26 24.5 31.5 30 28.5 27 36 35 33.5 32 33.5 33 32 31 43 41.5 40 38 53.5 52 51 49.5

100 110

120 130

150 160

9 16 23 25 30 30 36 48

7 14 21

12 18

9 15

27.5 25 22 29 28 26.5 25 23 34.5 32.5 30.5 28 26 46 44.5 42.5 40.5 38.5

21 36

19

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


f a
DN2

h2
DN1

w TYPE Single-phase Three-phase CPm 100 CP 100 CPm 130 CP 130 CPm 132B CP 132B CPm 132A CP 132A CPm 152 CP 152 CPm 150 CP 150 CPm 158 CP 158 CPm 170-170M CP 170-170M CPm 190 CP 190 CP 200 PORTS
DN1 DN2

n1 DIMENSIONS mm h1 h2 n 77 110 148 82 123 165 123 165 82 123 165 82 123 165 92 148 190 92 148 190 92 148 190 110 150 206 115 175 242 242 115 175 115 175 242

s kg n1 118 135 135 135 135 160 160 160 165 206 206 206 w 45 41 41 41 38 38 38 44.5 32.5 32.5 32.5 s 10 10 10 10 10 10 10 10 11 11 11 1~ 6.8 7.8 8.0 8.4 11.5 12.5 12.1 19.2 25.0 3~ 6.9 7.6 7.5 8.1 11.5 11.3 11.6 18.5 24.2 25.5

1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4"

1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"

a 34 42 42 42 42 42 42 42 51 51 51.5

f 247 259 259 259 266/259 285 285 285 367 338 364 338

h 187 205 205 205 240 240 240 260 290 290 290

h1

29

stainless steel centrifugal pumps

RANGE OF PERFORMANCE Maximum flow rate 160 l/min (9.6 m3/h) Maximum head 23 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Environment temperature up to + 55C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


INSTALLATION AND USE


It is recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. THE CONSTRUCTION OF THESE CENTRIFUGAL PUMPS MAKES THEM SUITABLE FOR USE IN THE DOMESTIC, AGRICULTURAL AND INDUSTRIAL SECTOR. ALL THE WETTED PARTS ARE IN STAINLESS STEEL AISI 340 TO GUARANTEE TOTAL HYGIENE AND MAXIMUM RESISTANCE TO CORROSION. The pump must be installed in enclosed places, or at least protected against inclement weather.

PUMP BODY: stainless steel AISI 304, with threaded ports ISO 228/1. BODY BACK-PLATE AND DIFFUSER: AISI 304. IMPELLER: stainless steel AISI 304, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. AL-RED 135m: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. AL-RED 135: three-phase 230/400 V - 50 Hz. INSULATION : class F. PROTECTION: IP 44. REGISTERED MODEL n 72753. AL-RED is a REGISTERED TRADE MARK

OPTIONS ON REQUEST

version in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal other voltages or frequency 60 Hz

30

CURVES AND PERFORMANCE DATA AT n= 2900 1/min


0 5 5 10 10 15 15 20 20 25 30 25 35 30 40 35 45 40 feet 90 0

30

25

80

AL-RED135

70
51 54

20
Head H (metres)

60

15

=56%

50

40
53

10
30

20

5
10

0
0 1

25
2

50
3 4

75
5

100
Flow rate Q
1.2 20 21 2.4 40 20.5
6 7

125
8

150
9 10

175
11

l/min
m3/h

TYPE
Single-phase Three-phase AL-RED 135m AL-RED 135

POWER
kW HP

m3/h l/min

0 0 23

3.6 60 20

4.8 80 18.5

6.0 100 17

7.2 120 15

8.4 140 13

9.6 160 10

0.75

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

DN1

h2
s w n1 TYPE Single-phase Three-phase PORTS
DN1 DN2

DIMENSIONS mm a 31.5 f 295 h 206 h1 97 h2 103 h3 200 n 182 n1 115 w 93 s 10 1~ 9.1

h1

h3

kg 3~ 9.1

AL-RED 135m AL-RED 135

11/4"

1"

31

close-coupled centrifugal pumps with threaded ports

Electric pumps with high efficiency motor for reduced energy consumption

RANGE OF PERFORMANCE Flow rate up to 900 l/min (54 m3/h) Head up to 75 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. RELIABLE AND MAINTENANCE FREE THEY ARE WIDELY USED IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL SECTORS, FOR SUPPLYING WATER, FOR CONDITIONING OR COOLING SYSTEMS, FOR IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: cast iron. IMPELLER: brass for pumps CP 220, CP 230. IMPELLER: cast iron for pumps CP 250. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, with high efficiency (class EFF1), quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. CP: three-phase 230/400 V - 50 Hz up to4 kW. 400/690 V - 50 Hz from 5.5 to 11 kW. INSULATION: class F. PROTECTION IP 44. REGISTERED MODEL n 72753 PATENTED ELECTRIC MOTOR

OPTIONS ON REQUEST

pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal protection IP 55 other voltages or frequency 60 Hz

32

PERFORMANCE RANGE AT n= 2900 1/min

Head H (metres)

Flow rate Q

33

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

CP220AH CP220A
50 54 56 57 58

=60%

Head H (metres)

CP220C

NPSH (metres)

Absorbed power P2 (kW)

AH A B C

Flow rate Q

TYPE
Single-phase Three-phase

POWER
kW HP

m3/h l/min

0 0 32 38 49 52

3 50 31.5 37.5 48.5 51.5

6 100 31 37 48 51

12 200 30 36 46 49

18 300 28 33.5 43.5 47

24 400 24 29 39.5 44

27 450 21 25 36 42

CPm 220C CPm 220B

CP 220C CP 220B CP 220A CP 220AH

2.2 3 4 5.5

3 4 5.5 7.5

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

34

P2 (HP)

NPSH (feet)

H (feet)

CP220B

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Single-phase Three-phase

POWER
kW HP

m3/h l/min

0 0 30 39 46

6 100 29.5 38.5 45.5

12 200 28.5 38 44.5

18 300 27 36 42

24 400 25 34 40

30 500 22 31 37

36 600 19.5 28 32.5

42 700 15.5 24 27.5

48 800 11.5 18.5 21.5

51 850 9 15 18

54 900 13 15

CPm 230C CP 230C CP 230B CP 230A

3 4 5.5

4 5.5 7.5

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

35

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase CP 250C CP 250B CP 250A CP 250CR CP 250BR CP 250AR

POWER
kW HP

m3/h l/min

0 0 57 66 74 57 66 74

6 100 56 65 73 56 65 73

12 200 54.5 62.5 71 54.5 62.5 71

18 300 52.5 60 68 52.5 60 68

24 400 49.5 57 65 49.5 57 65

30 500 46 53 61 46 53 61

36 600 41.5 49 57 41.5 49 57

42 700 35.5 43.5 51 35.5 43.5 51

48 800 30 37.5 45 30 37.5 45

54 900 24 30 37 24 30 37

7.5 9.2 11 7.5 9.2 11

10 12.5 15 H metres 10 12.5 15

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

36

P2 (HP)

NPSH (feet)

H (feet)

DIMENSIONS AND WEIGHTS


f a
DN2

h2
DN1

s w n1 n2

TYPE Single-phase
CPm 220C CPm 220B CPm 230C

PORTS
DN1 DN2

DIMENSIONS mm a
70 70 70 70 70 70 70 65 65 65 92 92 92

h1

kg n1
170 190 190 190 190 190 190 230 230 230 230 230 230 230

Three-phase
CP 220C CP 220B CP 220A CP 220AH CP 230C CP 230B CP 230A CP 250C CP 250B CP 250A CP 250CR CP 250BR CP 250AR

f
421/402 459 505 459 505 507 571 571 571 534 598 598 598

h
315 328 328 328 328 328 328 392 392 392 392 392 392 392

h1
132 136 136 136 136 136 136 160 160 160 160 160 160 160

h2
183 192 192 192 192 192 192 232 232 232 232 232 232 232

n
255 273 273 273 273 273 273 322 322 322 322 322 322 322

n2
230 250 250 250 250 250 250 294 294 294 294 294 294 294

w
40 40 40 40 40 40 40 40 45 45 45 45 45 45 45

s
14 14 14 14 14 14 14 14 14 14 14 14 14 14

1~ 33.3 44.0 41.3 -

3~ 30.5 33.3 41.0 47.6 33.0 41.3 47.6 74.0 96.0 103.0 78.0 100.0 107.0

2"
2" 2" 2" 2" 2" 2" 2" 2" 2" 4" 4" 4" 4"

2"
2" 2" 2" 2" 2" 2" 2" 2" 2" 3" 3" 3" 3"

459/421 328/315 136/132 192/183 273/255 190/170 250/230

2"

2"

459/421 328/315 136/132 192/183 273/255 190/170 250/230

37

standardised centrifugal pumps to EN 733 - DIN 24255

RANGE OF PERFORMANCE Flow rate up to 250 l/min (15 m3/h) Head up to 57 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. THE PUMPS IN THIS SERIES ARE MADE TO STANDARDS EN 733 - DIN 24255 AND ARE SPECIFICALLY USED IN THE CIVIL, INDUSTRIAL OR AGRICULTURAL SECTORS WHERE THEIR CHARACTERISTICS OF STURDINESS AND RELIABILITY CAN BE BEST APPRECIATED. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, made to standards EN 733 - DIN 24255 and UNI 7467- NF E-44-111, with threaded ports ISO 228/1. IMPELLER: brass, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. CPm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector up to 1.5 kW. CP: three-phase 230/400 V - 50 Hz. INSULATION : class F. PROTECTION: IP 44.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz

38

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

CP25/200A
42 45

CP25/200B

47

Head H (metres)

=49%
CP25/160AR CP25/160A CP25/160B
50 47 53 45

=56%
53 50

42

Flow rate Q

TYPE
Single-phase CPm 25/160B CPm 25/160A CPm 25/200B Three-phase CP 25/160B CP 25/160A CP 25/160AR CP 25/200B CP 25/200A

POWER
kW HP

m3/h l/min

0 0 33 38 42 49 57

3.0 50 32.5 37 41 48 56

3.6 60 32 36.8 41 47.5 55.8

4.2 70 31.5 36.5 40.5 47 55.5

4.8 80 31 36 40 46.5 55

5.4 90 30.5 35.5 39.5 45.5 54.5

6.0 100 30 35 39 45 53.5

6.6 110 29 34 38 44 53

7.5 125 28 33 37 43 52

8.4 140 26.5 31.5 36 41 50.5

9.6 160 24 29.5 34 38.5 48.5

10.8 180 21.5 27 31 36 46

12.0 200 18 24 28 32 43.5

13.2 220 20 24 28 40

15.0 250

1.1 1.5 2.2 2.2 3

1.5 2 3 3 4

H metres

22 33

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

h2
DN1

w1

w2

n1

TYPE Single-phase Three-phase CPm 25/160B CP 25/160B CPm 25/160A CP 25/160A CP 25/160AR CPm 25/200B CP 25/200B CP 25/200A

PORTS
DN1 DN2

11/2" 11/2" 11/2"" 1/2 11/2" 11/2"

1" 1" 1" 1" 1" 1"

a 56 56 56 56 60 60 60

f 360 386 380 384/359 384

h 260 260 260 260 305 305 305

h1 105 105 105 125 125 125

DIMENSIONS mm h2 n 155 206 206 155 155 206 180 252 252 180 180 252

h1

kg n1 150 150 150 210 210 210 w1 27.5 27.5 27.5 23.5 23.5 23.5 w2 27.5 27.5 27.5 39.5 39.5 39.5 s 10 10 10 10 11 11 11 1~ 20.7 21.7 31.0 3~ 18.7 21.0 21.8 28.6 30.7

39

centrifugal pumps
medium flow rates

RANGE OF PERFORMANCE Flow rate up to 600 l/min (36 m3/h) Heads up to 39 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
THE HF SERIES IS RECOMMENDED FOR CIVIL, AGRICULTURAL AND INDUSTRIAL APPLICATIONS. THE HIGH FLOW RATES AND CONTINUOUS RATING MAKE IT IDEAL FOR IRRIGATION WITH FLOWING AND SPRINKLING WATER, FOR DRAWING WATER FROM LAKES, RIVERS, WELLS, OR FOR INDUSTRIAL APPLICATIONS THAT NEED TO ACHIEVE LARGE FLOW RATES AT MEDIUM-LOW HEADS. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. IMPELLER: brass, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. HFm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. HF: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz

40

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

HF70A

HF70B

HF60

Head H (metres)

HF5AM HF51A HF51B HF5A HF5B HF5C HF5BM

HF50A HF50B

Flow rate Q

TYPE
Single-phase HFm 50B HFm 50A HFm 51B HFm 51A HFm 60 HFm 70B HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM Three-phase HF 50B HF 50A HF 51B HF 51A HF 60 HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM

POWER
kW HP

m3/h l/min

0 0 9 12 18.2 21.2 29 33 39 12.5 13.7 14.5 20.2 22.5

3 50 8.5 11.5 17.2 20.2 28 32 38

6 100 8.2 11.2 16 19 26.5 30.5 36.5 12 13.2 13.8 19.2 22

9 150 7.5 10.6 14 17 24.5 28.5 34.5 11.7 13 13.5 19 21.5

12 200 6.3 9.6 11.5 14.5 22 26 32 11 12.5 13.2 18 21

15 250 4.9 8 9 11.6 18.5 22.5 28.5 10.2 11.6 12.6 17 20

18 300 2.8 6 5.4 8.4 15 19 25 9.2 10.5 11.8 16 18.5

21 350

24 400

30 500

36 600

0.37 0.55 0.60 0.75 1.1 1.5 2.2 0.60 0.75 1.1 1.1 1.5

0.50 0.75 0.85 1 1.5 2 H metres 3 0.85 1 1.5 1.5 2

8 9.2 10.5 14 16.6

6.5 8 9.2 12 14.5

5 6.5 7.5 10

Q = Flow rate H = Total manometric head f a


DN2

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


n

h2
DN1

w TYPE Single-phase HFm 50B HFm 50A HFm 51B HFm 51A HFm 60 HFm 70B HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM PORTS Three-phase HF 50B HF 50A HF 51B HF 51A HF 60 HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM
DN1 DN2

n1 DIMENSIONS mm h1 h2 n 82 118 165 82 118 165 82 118 165 92 133 190 92 133 190 92 133 190 114 155 216 114 155 216 114 155 216 114 155 216 97 141 196 97 141 196 97 141 196 97 141 196 110 150 206 110 150 206 110 150 206

s kg n1 135 135 135 160 160 160 171 171 171 171 160 160 160 160 160 160 w 1 1 1 4 4 4 12 12 12 14 14 14 14 1 1 1 s 10 10 10 10 10 12 12 12 11 11 11 11 11 1~ 8.3 8.9 15.5 13.0 20.0 22.2 15.3 15.1 15.5 20.3 22.2 3~ 8.2 8.4 15.1 12.1 19.3 21.6 22.8 14.2 14.3 15.2 19.5 21.8

11/2" 11/2" 11/2" 11/2"" 1/2 11/2" 11/2" 11/2" 2" 2" 2" 2" 2" 2"

11/2" 11/2" 11/2" 11/2"" 1/2 11/2" 11/2" 11/2" 2" 2" 2" 2" 2" 2"

a 45 45 45 45 45 48.5 48.5 48.5 48.5 60 60 60 60 51 51 51

f 276 283/276 300 300 300 347 373 367 332 332 332 360 386 380/360

h 200 200 200 225 225 225 269 269 269 238 238 238 260 260 260

h1

41

centrifugal pumps
high flow rates

RANGE OF PERFORMANCE Flow rate up to 1800 l/min (108 m3/h) Head up to 24.5 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
THE HF SERIES IS RECOMMENDED FOR USE IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL FIELD. THE HIGH FLOW RATES AND CONTINUOUS RATING MAKE IT IDEAL FOR IRRIGATION WITH FLOWING AND SPRINKLING WATER, FOR DRAWING WATER FROM LAKES, RIVERS, WELLS, OR FOR INDUSTRIAL APPLICATIONS THAT NEED TO ACHIEVE LARGE FLOW RATES AT MEDIUM-LOW HEADS. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. IMPELLER: brass, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.. HFm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. HF: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz

42

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

HF8A HF30A HF8B

HF6A-6AR

HF20A HF30B

Head H (metres)

HF20B HF6B-6BR

HF6C-6CR

HF4

100

Flow rate Q

TYPE
Single-phase HFm 4 HFm 6C HFm 6B HFm 6CR HFm 6BR HFm 8B HFm 20B Three-phase HF 4 HF 6C HF 6B HF 6A HF 6CR HF 6BR HF 6AR HF 8B HF 8A HF 20B HF 20A HF 30B HF 30A

POWER
kW HP Q

m3/h l/min

12 200 9.3 11.7 14.5 18.1 11.7 14.5 18.1 21 24 -

18 300 8.7 11.3 14 17.8 11.3 14 17.8 20.7 23.5 -

24 400 8 10.7 13.5 17.2 10.7 13.5 17.2 20 23 15.5 18.5 -

30 500 7 10.2 12.8 16.8 10.2 12.8 16.8 19.5 22.5 15.4 18.4 -

36 600 6 9.2 12 16 9.2 12 16 18.8 21.8 15.3 18.3 18 23

42 700 4.7 8 11 15 8 11 15 17.8 20.8 15.2 18.2 18 23

48 800 3 6.7 9.7 13.8 6.7 9.7 13.8 16.5 19.5 15 18 18 23

54

60

66

72

84

96

102 108 120 132

0.75 1.1 1.5 2.2 1.1 1.5 2.2 3 4 3 4 5.5 7.5

1 1.5 2 3 1.5 2 3 4 5.5 4 5.5 7.5 10

0 10 11.9 14.7 18.5 11.9 14.7 H metres 18.5 21.5 24.5 16 19 18 23

900 1000 1100 1200 1400 1600 1700 1800 2000 2200 5 8.2 12.2 5 8.2 12.2 15 18.3 14.5 17.5 18 23 3 6.7 10.5 3 6.7 10.5 13.5 16.8 14 17 18 23

5 8.3

5 8.3 6 11.2 9 15 13 13 12 9 4.8 2 16.2 15.2 12 7.8 5 2 17.5 17 16.5 15.5 15 14.5 13 22.5 22.5 22.5 22 21.5 21 19.5

18

Q = Flow rate H = Total manometric head f a


DN2

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


n

h2
DN1

w TYPE Single-phase Three-phase HFm 4 HF 4 HFm 6C HF 6C HFm 6B HF 6B HF 6A HFm 6CR HF 6CR HFm 6BR HF 6BR HF 6AR HFm 6B HF 8B HF 8A HFm 20B HF 20B HF 20A HF 30B HF 30A PORTS
DN1 DN2

n1 a 55 68 68 68 68 70 70 70 70 80 80 80 80 80 82 82 82 f 323 385 405/385 411 405 387 407/387 413 407 462/429 462 462/429 462 585 585 585 h 240 312 312 312 312 312 312 312 312 312 312 312 370 370 370 DIMENSIONS mm h1 h2 n 97 143 190 120 192 240 120 192 240 120 192 240 120 192 240 120 192 240 120 192 240 120 192 240 132 180 245 132 180 245 132 180 245 132 180 245 132 180 245 160 210 292 160 210 292 160 210 292

s kg n1 155 190 190 190 190 190 190 190 190 190 190 190 212 212 212 w 0 6 6 6 6 6 6 6 30 30 30 30 30 30 30 s 10 12 12 12 12 12 12 12 14 14 14 14 14 14 14 1~ 15.6 28.1 29.1 29.7 32.0 41.0 40.5 3~ 14.2 26.2 28.5 29.4 29.2 31.4 32.3 36.1 41.0 35.3 40.5 60.9 65.2

21/2" 3" 3" 3" 3" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"

21/2" 3" 3" 3" 3" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"

h1

43

centrifugal pumps with flanged ports

RANGE OF PERFORMANCE Flow rate up to 1200 l/min (72 m3/h) Head up to 22.5 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
THE NF SERIES, FROM THE POINT OF VIEW OF BOTH PERFORMANCE AND MECHANICAL DIMENSIONS, HAS BEEN EXPRESSLY DESIGNED FOR USE IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL FIELD. THE HIGH FLOW RATES AND CONTINUOUS RATING MAKE IT IDEAL FOR IRRIGATION WITH FLOWING AND SPRINKLING WATER, FOR DRAWING WATER FROM LAKES, RIVERS, WELLS, AND FOR TRANSFER IN GENERAL. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded suction and delivery FLANGES ISO 228/1. IMPELLER: brass, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. NFm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. NF: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz

44

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

NF129A

NF129B

NF130A

Head H (metres)

NF130B

NF128 AR NF128A NF128B


NF130C

Flow rate Q

TYPE
Single-phase NFm 128B NFm 128A NFm 128AR NFm 129B NFm 129A NFm 130C NFm 130B Three-phase NF 128B NF 128A NF 128AR NF 129B NF 129A NF 130C NF 130B NF 130A

POWER
kW HP

m3/h l/min

0 0

6 100

9 150 11.7 13 13.5 19 21.5

12 200 11 12.5 13.2 18 21 11.7 14.5 18.1

15 250 10.2 11.6 12.6 17 20 11.5 14.2 18

18

21

24 400

30 500

36 600

42 700

48 800

54

60

66

72

300 350 9.2 10.5 11.5 16 18.5 11.3 14 17.8 8 9.2 10.5 14 16.6 11.1 13.7 17.5

900 1000 1100 1200

0.60 0.75 1.1 1.1 1.5 1.1 1.5 2.2

0.85 1 1.5 1.5 H metres 2 1.5 2 3

12.5 12 13.7 13.2 14.5 13.8 20.2 19.2 22.5 22 11.9 14.7 18.5

6.5 8 5 9.2 6.5 12 7.5 14.5 10 10.7 10.2 13.5 13.2 17.2 16.8

9.1 12 16

8 11 15

6.7 5 9.7 8.2 13.8 12.2

3 6.7 5 10.5 8.3

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

h2
DN1

w1

w2

n1 DIMENSIONS mm h2 h3 n 167 264 196 167 264 196 167 264 167 264 196 159 269 206 159 269 206 159 269 206 193 313 240 193 313 193 313 240 193 313 240

TYPE Single-phase Three-phase NFm 128B NF 128B NFm 128A NF 128A NFm 128AR NF 128AR NFm 129B NF 129B NFm 129A NF 129A NFm 130C NF 130C NFm 130B NF 130B NF 130A

PORTS
DN1 DN2

h1
2" 2" 2" 2" 2" 2" 3" 3" 3" 3" 2" 2" 2" 2" 2" 2" 3" 3" 3" 3" a 65 65 65 56 56 56 71 71 71 f 344 344 344 344 372 398 392/372 390 416 410/390 410 h 271 271 271 276 276 276 320 320 320 h1 97 97 97 110 110 110 120 120 120 n1 160 160 160 160 160 160 190 190 190 w1 8 8 8 1 1 1 6 6 6 kg* w2 s 1~ 3~ 60 12 19.8 17.1 60 12 18.3 17.0 60 12 18.3 18.3 62 11 23.3 22.7 62 11 62 11 26.0 24.6 66 12 33.5 31.5 12 34.4 33.4 66 66 12 34.6 (*weight includes counterflanges)

h3

45

centrifugal pumps with open impeller

Centrifugal pumps made of cast iron, equipped with open impeller, ideal for transferring liquids containing impurities.

RANGE OF PERFORMANCE Flow rate up to 350 l/min (21 m3/h) Head up to 20 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Liquid temperature up to + 40C in the NGAX version (with technopolymer impeller) Environment temperature up to + 40C Passage of solid bodies 10 mm CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping water and liquids that are chemically non aggressive to the materials from which the pump is made. THE OPEN IMPELLER DESIGN ALLOWS THE PUMPING OF LIQUIDS WITH RELATIVELY HIGH LEVELS OF IMPURITIES WITHOUT RISK OF CLOGGING THE IMPELLER. FOR THIS REASON THE NGA SERIES ARE SUITABLE FOR USE IN INDUSTRY, FOR THE TRANSFER OF WATER FROM CANALS, RIVERS, RESERVOIRS, TANKS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 304. OPEN IMPELLER: stainless steel AISI 316. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. NGAm: single-phase 230V - 50 Hz with capacitor and thermal overload protector. NGA: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

OPTIONS ON REQUEST

impeller in technopolymer (NGAm...X - NGA...X) special mechanical seal other voltages or frequency 60 Hz

46

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

NGA1A NGA1B

Head H (metres)

Flow rate Q

TYPE
Single-phase NGAm 1B NGAm 1A Three-phase NGA 1B NGA 1A

POWER
kW HP

m3/h l/min

0 0 18 20

3 50 17 19.5

6 100 16 18

9 150 14.5 16.5

12 200 13 15

15 250 10.5 12.5

18 300 8 10

19.5 325 6 8

21 350 6

0.55 0.75

0.75 H metres 1

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

h2
DN1

n1

TYPE Single-phase Three-phase NGAm 1B NGA 1B NGAm 1A NGA 1A

PORTS
DN1 DN2

11/2" 11/2" 11/2" 11/2" 11/2" 11/2"

a 41 41 41

f 297 297 297

h 227 227 227

DIMENSIONS mm h1 h2 n 92 135 190 135 190 92 92 135 190

h1
s

kg n1 160 160 160 w 50 50 50 s 10 10 10 1~ 12.7 12.8 3~ 11.8 11.9

47

stainless steel pumps

Centrifugal pumps made of stainless steel AISI 316, equipped with an open impeller, ideal for transferring liquids containing impurities.

RANGE OF PERFORMANCE Flow rate up to 350 l/min (21 m3/h) Head up to 20 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Environment temperature up to + 40C Passage of solid bodies 10 mm CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping water and liquids that are chemically non aggressive to the materials from which the pump is made. THE OPEN IMPELLER DESIGN ALLOWS THE PUMPING OF LIQUIDS WITH RELATIVELY HIGH LEVELS OF IMPURITIES WITHOUT RISK OF CLOGGING THE IMPELLER. FOR THIS REASON THE PRO-NGA SERIES ARE SUITABLE FOR USE IN SYSTEMS FOR WASHING FRUIT, VEGETABLES, FISH, SHELLFISH, MEAT, IN INDUSTRIAL SYSTEMS FOR WASHING METAL PARTS, GLASS CONTAINERS, AND FOR THE CIRCULATION OF COOLING LIQUIDS. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: stainless steel AISI 316, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 316. OPEN IMPELLER: stainless steel AISI 316. MOTOR SHAFT: stainless steel AISI 316. MECHANICAL SEAL: ceramic - graphite - viton - AISI 316 ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. PRO-NGAm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. PRO-NGA: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz protection IP 55

48

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PRO-NGA1A PRO-NGA1B

Head H (metres)

Flow rate Q

TYPE
Single-phase Three-phase PRO-NGAm 1B PRO-NGA 1B PRO-NGAm 1A PRO-NGA 1A

POWER
kW HP

m3/h l/min

0 0 18 20

3 50 17 19.5

6 100 16 18

9 150 14.5 16.5

12 200 13 15

15 250 10.5 12.5

18 300 8 10

19.5 325 6 8

21 350 6

0.55 0.75

0.75 H metres 1.00

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

h2
DN1

s n1

TYPE Single-phase Three-phase PRO-NGAm 1B PRO-NGA 1B PRO-NGAm 1A PRO-NGA 1A

PORTS
DN1 DN2

11/2" 11/2" 11/2"

11/2" 11/2" 11/2"

a 41 41 41

f 297 297 297

h 227 227 227

DIMENSIONS mm h1 h2 n 92 135 190 135 190 92 92 135 190

h1

kg n1 160 160 160 w 50 50 50 s 10 10 10 1~ 13.0 13.1 3~ 12.0 12.1

49

two stage centrifugal pumps

Two stage pumps recognised for their high efficiency, versatility and quiet running.

RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 112 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 90C Liquid temperature up to + 40C in the 2CPX version (with technopolymer impeller) Environment temperature up to+ 40C CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. THEIR HIGH EFFICIENCY AND ADAPTABILITY TO THE MOST VARIED, EVEN UNUSUAL APPLICATIONS, MAKE THEM THE IDEAL CHOICE IN THE DOMESTIC, CIVIL AND INDUSTRIAL FIELD; IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH PRESSURE SETS, FOR INCREASING PRESSURE IN THE MAINS, FOR FIREFIGHTING SETS. The pumps must be installed in enclosed places, or at least protected against inclement weather.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, with high efficiency (class EFF1 for powers from 4 to 7.5 kW), quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. 2CPm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector (up to 1.5 kW). 2CP: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 7.5 kW. INSULATION: class F. PROTECTION: IP 44.

2CP 25/130N

PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 304. IMPELLER: stainless steel AISI 304 of the type with centrifugal radial flow.

Other 2CP

PUMP BODY: cast iron, with threaded ports ISO 228/1. IMPELLERS: brass, of the type with centrifugal radial flow.

OPTIONS ON REQUEST

impeller in technopolymer (2CPm...X - 2CP...X) special mechanical seal other voltages or frequency 60 Hz

50

RANGE OF PERFORMANCE AT n= 2900 1/min

Head H (metres)

Flow rate Q

51

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Single-phase 2CPm 25/130N 2CPm 25/140H 2CPm 160/160 Three-phase 2CP 25/130N 2CP 25/140H 2CP 160/160

POWER
kW HP

m3/h l/min

0 0 42 54 66

1.2 20 39 53 64

1.8 30 37 51 62

2.4 40 34 49 60

3.0 50 31 46 57

3.6 60 28.5 42 53

4.2 70 25.5 38 49

4.8 80 22 34 44

5.4 90 18 29 39.5

6.0 100 15 24 35

0.75 1.1 1.5

1 1.5 2

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

52

P2 (HP)
6.6 110 30

NPSH (feet)

H (feet)

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Single-phase
2CPm 25/140M 2CPm 25/160B

POWER
kW 1.1 1.5 2.2 HP 1.5 2 3 Q

m3/h l/min

0 0 47

1.2 20 46 56

1.8 30 45.5 55

2.4 40 44 54 65

3.0 50 43 53 63

3.6 60 42 52 62

4.2 70 41 50 60

4.8 80 38 48 58

5.4 90 36 46 56

6.0 100 34 44 54

6.6 110 31 41 51

7.5 125 27 37 47

8.4 140 22 33 42

9.6 160 26 35

Three-phase
2CP 25/140M 2CP 25/160B 2CP 25/160A

H metres 58 68

66.5 65.5

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)
10.8 180 28

NPSH (feet)

H (feet)

53

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Single-phase
2CPm 32/200C

POWER
kW 3 4 HP 4 5.5 Q

m3/h l/min

0 0 70 85

2.4 40 81

3.0 50 80

3.6 60 65 79

4.2 70 64 78

4.8 80 63 77

5.4 90 62 76

6.0 100 60.5 75

6.6 110 59 74

7.5 125 57 72

8.4 140 55 69

9.6 160 52 66

10.8 12.0 15.0 180 62 200 58 250 36 49

Three-phase
2CP 32/200C 2CP 32/200B

H metres

66.5 65.5

49.5 46.5

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

54

P2 (HP)

NPSH (feet)

H (feet)

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase 2CP 32/210B 2CP 32/210A

POWER
kW HP Q

m3/h l/min H metres

0 0 94 112

2.4 40 94 111

3.0 50 93.5

3.6 60 93

4.2 70 92

4.8 80 91 110

5.4 90 90 109

6.0 100 89 108

6.6 110 87 107

7.5 125 85 105

8.4 140 83 102

9.6 160 79 99

10.8 180 75 94

12.0 200 70 89

15.0 250 56 74

5.5 7.5

7.5 10

110.8 110.5 110.3

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

55

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase 2CP 40/180C 2CP 40/180B 2CP 40/180A

POWER
kW HP

m3/h l/min

0 0 64 76 88

6.0 100 62 73 85

6.6 110 61 72.5 84.5

7.5 125 60 72 84

8.4 140 59 71 83

9.6 160 58 70 82

10.8 180 56 69 81

12.0 200 54.5 67.5 79.5

15.0 250 49 64 76

18.0 300 43 59.5 72

21.0 350 35 54 67

24.0 400 46 60

4 5.5 7.5

5.5 7.5 10

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

56

P2 (HP)

NPSH (feet)

H (feet)

DIMENSIONS AND WEIGHTS

f a
DN2

h2
DN1

s n1

TYPE Single-phase
2CPm 25/130N 2CPm 25/140H 2CPm 160/160 2CPm 25/140M 2CPm 25/160B 2CPm 32/200C

PORTS
DN1 DN2

DIMENSIONS mm a
73 74 84 74 86 86 86 95 95 95 108 108 108 108 108 108

h1

kg n1
142 162 185 162 185 185 185 206 206 206 232 232 232 232 232 232

Three-phase
2CP 25/130N 2CP 25/140H 2CP 160/160 2CP 25/140M 2CP 25/160B 2CP 25/160A 2CP 32/200C 2CP 32/200B 2CP 32/210B 2CP 32/210A 2CP 40/180C 2CP 40/180B 2CP 40/180A

f
330 382 405 382 401/381 407 401 464 464 464 542 542 542 496 542 542 542

h
201 225 263 225 263 263 263 304 304 304 334 334 334 334 334 334

h1
92 93 110 93 110 110 110 132 132 132 139 139 139 139 139 139

h2
109 132 153 132 153 153 153 172 172 172 195 195 195 195 195 195

n
180 200 225 200 225 225 225 266 266 266 292 292 292 292 292 292

w
1 23 26 23 26 26 26 19 19 19 21 21 21 21 21 21

s
10 10 10 11 10 11 11 11 14 14 14 14 14 14 14

1~
14.5 20.1 24.8 20.1 24.6 42.9 -

3~
14.0 19.4 24.1 19.2 25.2 26.1 39.1 42.9 56.0 61.7 49.8 55.1 60.8

11/4" 11/4"" 11/4 11/4" 11/2" 11/2"

1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/2"

1"

11/2"" 1/2
11/2" 11/2" 2" 2"

11/4"

2" 2"
2" 2"

11/2 11/2" "


11/2"

57

multi-stage centrifugal pumps

Particularly quiet running with high efficiency and low power consumption. Suitable for domestic applications.

RANGE OF PERFORMANCE Flow rate up to 130 l/min (7.8 m3/h) Head up to 50 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 40C Environment temperature up to+ 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 304. IMPELLERS: of the type with centrifugal radial flow, made of technopolymer (approved for drinking water). MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104 MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.. 2-3-4CPm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. 2-3-4CP: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. DUE TO THEIR RELIABILITY, QUIET RUNNING AND LOW MAINTENANCE, THEY ARE SUITABLE FOR DOMESTIC APPLICATIONS INCLUDING WATER SUPPLIES (AS A PRESSURE SET), GARDEN IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

OPTIONS ON REQUEST

other voltages or frequency 60 Hz

58

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4CP80E

4CP100E

3CP80E

Head H (metres)

3CP100E

2CP80E

Flow rate Q

TYPE
Single-phase 2CPm 80E 3CPm 80E 4CPm 80E 3CPm 100E 4CPm 100E Three-phase 2CP 80E 3CP 80E 4CP 80E 3CP 100E 4CP 100E

POWER
kW HP

m3/h l/min

0 0 27 38 50 36 46

0.3 5 26 36 48 35.5 45

0.6 10 25 35 47 35 44

0.9 15 24 34 45 34 43

1.2

1.5

1.8

2.4

3.0

3.6

4.2 70 5 10 16 23 30

4.8 80

5.4 90

6.0

6.6

7.2

7.8

0.37 0.45 0.60 0.60 0.75

0.50 0.60 0.85 H metres 0.85 1

20 25 30 40 50 60 22.5 21 20 16.5 13 9 33.5 31 29 25 20 15.5 43 40.5 38.5 33.5 28 22.5 33.5 32.5 32 30 28 26 42 41 40 38 35.5 33

100 110

120 130

5 10 20 17 13.5 26.5 22.5 19

10 15

5 10

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

DN1

h2
w n1 s PORTS
DN1 DN2

TYPE Single-phase Three-phase 2CPm 80E 2CP 80E 3CPm 80E 3CP 80E 4CPm 80E 4CP 80E 3CPm 100E 3CP 100E 4CPm 100E 4CP 100E

1" 1" 1" 1" 1" 1"

1" 1" 1" 1" 1" 1"

a 110 110 110 135 110 135

f 334 334 334 367/359 342/334 378

h 172 172 172 172 172 191

DIMENSIONS mm h1 h2 n 134 38 158 134 38 158 158 38 134 38 158 134 38 158 134 61 158

h1

kg n1 116 116 116 116 116 116 w 2 2 2 2 2 s 9 9 9 9 9 1~ 8.6 9.4 10.8 10.2 13.4 3~ 8.6 8.9 10.2 9.4 12.3

59

multi-stage centrifugal pumps


stainless steel pump body

Particularly quiet running with high efficiency and low power consumption. Suitable for domestic applications.

RANGE OF PERFORMANCE Flow rate up to 120 l/min (7.2 m3/h) Head up to 50 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 40C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: stainless steel AISI 304, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 304. IMPELLERS: of the type with centrifugal radial flow, made of technopolymer (approved for drinking water). MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.. 3-4CRm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. 3-4CR: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. DUE TO THEIR RELIABILITY AND QUIET RUNNING, THEY ARE SUITABLE FOR DOMESTIC APPLICATIONS INCLUDING WATER SUPPLIES (AS A PRESSURE SET), GARDEN IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz

60

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4CR80

3CR80

Head H (metres)

3CR100

Flow rate Q

TYPE
Single-phase 3CRm 80 4CRm 80 3CRm 100 Three-phase 3CR 80 4CR 80 3CR 100

POWER
kW HP

m3/h l/min

0.3 5 36 48 35.5

0.6 10 35 47 35

0.9 15 34 45 34

1.2

1.5

1.8

2.4 40 25 33.5 30

3.0 50 20 28 28

3.6 60 15.5 22.5 25.5

4.2 70 10 16 23

4.8 80 5 10 20

5.4 90

6.0 100

6.6 110

7.2 120

0.45 0.60 0.60

0 0.60 38 0.85 H metres 50 36 0.85

20 25 30 32.5 31 29 43 40.5 38.5 33.5 32.5 32

17

13.5

10

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

h2 h h1
DN1

s n1

TYPE Single-phase Three-phase 3CRm 80 3CR 80 4CRm 80 4CR 80 3CRm 100 3CR 100

PORTS
DN1 DN2

1" 1" 1" 1"

1" 1" 1" 1"

a 90 90 90

f 345 353/345 353/345 353/345

h 174 174 174

DIMENSIONS mm h1 h2 n 122 52 160 52 160 122 52 160 122 52 160

kg n1 120 120 120 w 95 95 95 s 9 9 9 1~ 6.9 7.6 7.5 3~ 6.3 6.9 6.9

61

JET self-priming pumps

RANGE OF PERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 47 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 40C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 304. EJECTOR ASSEMBLY: technopolymer (approved for drinking water). IMPELLER: brass. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite -NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.. JSWm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. JSW: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL n 72753.

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. JSW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCTION LIFTS AND CAN BE POSITIONED ABOVE THE WATER SOURCE, INCLUDING APPLICATIONS WITH AIR ENTRAINED IN THE WATER. DUE TO THEIR RELIABILITY AND LOW MAINTENANCE, THEY ARE RECOMMENDED FOR DOMESTIC USE, INCLUDING WATER DISTRIBUTION (AS PART OF A PRESSURE SET), GARDEN IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

OPTIONS ON REQUEST

impeller in technopolymer (JSWm1...X - JSW1...X) other voltages or frequency 60 Hz

62

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

JSW1A
HS

JSW1B

JSW1C

Head H (metres)

Flow rate Q

TYPE
Single-phase JSWm 1C JSWm 1B JSWm 1A Three-phase JSW 1C JSW 1B JSW 1A

POWER
kW HP

m3/h l/min

0 0 35 41 47

0.3 5 32 36 42

0.6 10 27 31 38

0.9 15 24 27 34

1.2 20 21 24 31

1.5 25 19 22 28.5

1.8 30 17 20 26

2.1 35 16 19 24

2.4 40 15 17 22

2.7 45 14 16 21.5

3.0 50 13 15 19

0.37 0.50 0.60

0.50 0.70 H metres 0.85

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

h2
DN1

h3

h1

s n1

TYPE Single-phase Three-phase JSWm 1C JSW 1C JSWm 1B JSW 1B JSWm 1A JSW 1A

PORTS
DN1 DN2

1" 1" 1" 1"

1" 1" 1" 1"

a 115 115 115 115

f 379 379 379 387/379

h 171 171 171 171

h1 127 127 127

DIMENSIONS mm h2 h3 33.5 160.5 160.5 33.5 33.5 160.5

kg n 160 160 160 n1 124 124 124 w 24 24 24 s 10 10 10 1~ 9.3 10.0 10.2 3~ 9.1 9.5 10.1

63

JET self-priming pumps

RANGE OF PERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 70 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 40C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 304. EJECTOR ASSEMBLY: technopolymer (approved for drinking water). IMPELLER: brass. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite -NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. JSWm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. JSW: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL n 72753.

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. JSW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCTION LIFTS AND CAN BE POSITIONED ABOVE THE WATER SOURCE, INCLUDING APPLICATIONS WITH AIR ENTRAINED IN THE WATER. DUE TO THEIR RELIABILITY AND LOW MAINTENANCE, THEY ARE RECOMMENDED FOR DOMESTIC USE, INCLUDING WATER DISTRIBUTION (AS PART OF A PRESSURE SET), GARDEN IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

OPTIONS ON REQUEST

impeller in technopolymer (JSWm...X - JSW...X) other voltages or frequency 60 Hz

64

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

JSW15H

JSW12H

JSW10H JSW15M JSW12M

Head H (metres)

JSW10M

Flow rate Q

TYPE
Single-phase JSWm 10H JSWm 12H JSWm 15H JSWm 10M JSWm 12M JSWm 15M Three-phase JSW 10H JSW 12H JSW 15H JSW 10M JSW 12M JSW 15M

POWER
kW HP

m3/h l/min

0 0 56 64 70 46 50 55

0.3 5 51 58 66 42 48 52

0.6 10 47 54 62 40 46 50

0.9 15 44 51 58 38 44 48

1.2 20 41 48 54 37 42 46

1.5 25 39 45 51 35 41 45

1.8 30 36 43 48 33 39 43

2.4 40 32 38 43 30 36 40

2.7 45 30 36 41 29 35 39

3.0 50 28 34 38 27 33 37

3.6 60

4.2 70

4.8 80

0.75 0.90 1.1 0.75 0.90 1.1

1 1.25 1.5 H metres 1 1.25 1.5

25 31 35

23 29 33

21 27 30

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2

h2 h3
DN1

h1

n1

TYPE Single-phase Three-phase JSWm 10H JSW 10H JSWm 12H JSW 12H JSWm 15H JSW 15H JSWm 10M JSW 10M JSWm 12M JSW 12M JSWm 15M JSW 15M

PORTS
DN1 DN2

1" 1" 1" 1" 1" 1" 1"

1" 1" 1" 1" 1" 1" 1"

a 113.5 113.5 113.5 113.5 113.5 113.5 113.5

f 402 402 402 402 402 402 402

h 201 201 201 201 201 201 201

h1 147 147 147 147 147 147 147

DIMENSIONS mm h2 h3 35 182 35 182 35 182 35 182 35 182 35 182 35 182

kg n 180 180 180 180 180 180 180 n1 142 142 142 142 142 142 142 w 22 22 22 22 22 22 22 s 10 10 10 10 10 10 10 1~ 13.7 15.0 15.2 13.7 15.0 15.2 3~ 13.8 14.0 14.2 13.8 14.0 14.2

65

JET self-priming pumps

RANGE OF PERFORMANCE Flow rate up to 160 l/min (9.6 m3/h) Head up to 96 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 40C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded ports ISO 228/1. BODY BACK-PLATE: cast iron. EJECTOR ASSEMBLY: technopolymer (approved for drinking water). IMPELLER: brass. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. JSWm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. JSW: three-phase230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL n 72753.

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. JSW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCTION LIFTS AND CAN BE POSITIONED ABOVE THE WATER SOURCE, INCLUDING APPLICATIONS WITH AIR ENTRAINED IN THE WATER. DUE TO THEIR RELIABILITY AND LOW MAINTENANCE, THEY ARE RECOMMENDED FOR DOMESTIC USE, INCLUDING WATER DISTRIBUTION (AS PART OF A PRESSURE SET), GARDEN IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz

66

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

JSW3AH

JSW3BH

JSW3AM

Head H (metres)

JSW3CH

JSW3BM

JSW3AL

JSW3CM

JSW3BL

JSW3CL

Flow rate Q

TYPE
Single-phase JSWm 3CH JSWm 3BH JSWm 3CM JSWm 3BM JSWm 3CL JSWm 3BL Three-phase JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL

POWER
kW HP

m3/h l/min

0 0

0.6 10 60 70 90 50 58 70 40 48 60

0.9 15 55 67 86 48 56 68 39 46 58

1.2 20 51 64 82 45 54 67 38 45 57

1.5 25 48 61 79 44 52 65 37 44 56

1.8 30 45 58 75 42 51 63 36 43 55

2.1 35 42.5 55.5 71.5 40 49 61 35 42 54

2.4 40 40 53 69 38 47 59 34 41 53

2.7 45 39 51 66 37 46 58 33 40 52

3.0 50 37 49 64 35 45 56 32 39 51

3.6 60 34 45 58 32 42 54 30 37 49

4.2 70 31 41 54 29 39 51 28 35 47

4.8 80 39 50 27 37 49 26 33 45

6.0

7.2

8.4

9.6

100 120

140 160

1.1 1.5 2.2 1.1 1.5 2.2 1.1 1.5 2.2

1.5 2 3 1.5 2 3 1.5 2 3

64 76 96 52 H metres 60 74 42 51 62

23 33 44 23 30 42

20 30 40 20 27 39

17 24 36.5

15 22 35

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


f a
DN2

h2

DN1

h3

h1

n1

TYPE Single-phase Three-phase JSWm 3CH JSW 3CH JSWm 3BH JSW 3BH JSW 3AH JSWm 3CM JSW 3CM JSWm 3BM JSW 3BM JSW 3AM JSWm 3CL JSW 3CL JSWm 3BL JSW 3BL JSW 3AL

PORTS
DN1 DN2

11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"

1" 1" 1" 1" 1" 1" 1" 1" 1" 1"

a 155 155 155 155 155 155 155 155 155

f 497 517/497 517 497 523 517/497 517 497 517/497 517

h 233 233 233 233 242 233 233 233 233 233

h1 165 165 165 165 165 165 165 165 165 165

DIMENSIONS mm h2 h3 43 208 43 208 43 208 43 208 43 208 43 208 43 208 43 208 43 208

kg n 206 206 206 206 206 206 206 206 206 n1 164 164 164 164 164 164 164 164 164 w 30 30 30 30 30 30 30 30 30 s 11 11 11 11 11 11 11 11 11 11 1~ 25.4 26.5 25.4 26.5 25.4 26.5 3~ 23.5 25.7 26.8 23.5 25.7 26.8 23.5 25.7 26.8

67

JET self-priming pumps for deep boreholes

RANGE OF PERFORMANCE Flow rate up to 3600 l/h

CONSTRUCTION CHARACTERISTICS

LIMITS OF USE Manometric suction lift up to 45 m Liquid temperature up to + 40C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

PUMP BODY: cast iron, with threaded ports ISO 228/1. EJECTOR BODY: cast iron NOZZLE, VENTURI AND DIFFUSER: technopolymer. IMPELLER: brass. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.. JDWm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. JDW: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

OPTIONS ON REQUEST INSTALLATION AND USE


JDW SELF-PRIMING PUMPS ARE DESIGNED FOR LIFTING WATER FROM DEPTHS GREATER THAN 9M, INCLUDING CASES WITH ENTRAINED AIR. THEY ARE RECOMMENDED FOR DOMESTIC USE INCLUDING WATER DISTRIBUTION (AS PART OF A PRESSURE SET), GARDEN IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

impeller in technopolymer (JDWm...X - JDW...X) other voltages or frequency 60 Hz

DESCRIPTION
Series Single-phase motor Motor size Type of nozzle and venturi Min. well diameter in inches

JDW m 1C / 30 - 4

GUARANTEE 2 YEARS subject to our general terms of sale.

68

JDW self-priming pumps for 4" wells


(with immersed ejector)

PERFORMANCE DATA AT n= 2900 1/min

TYPE
Single-phase
JDWm 1C/30 -4 JDWm 1B/30 -4 JDWm 1A/30 -4 JDWm 2/30 -4 JDWm 1C/20 -4 JDWm 1B/20 -4 JDWm 1A/20 -4 JDWm 2/20 -4 JDWm 1C/10 -4 JDWm 1B/10 -4 JDWm 1A/10 -4 JDWm 2/10 -4 JDWm 1C/30 -4 JDWm 1B/30 -4 JDWm 1A/30 -4 JDWm 2/30 -4 JDWm 2/20 -4 JDWm 1C/30 -4 JDWm -1B/30 -4 JDWm 1A/30 -4 JDWm 2/30 -4 JDWm 1A/30 -4 JDWm 2/30 -4 JDWm 2/30 -4 JDWm 2/30 -4 HS = Suction height

POWER
kW
0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 1.1 0.50 0.60 0.75 1.1 0.75 1.1 1.1 1.1

HS
metres

FLOW RATE LITRES/HOUR


0 120 240 360 480 600 720 840 960 1080 1200 1440 1560 1680 1800 1920 2040 2160 2400 2700 3000 3300 3600

Three-phase
JDW 1C/30-4 JDW 1B/30-4 JDW 1A/30-4 JDW 2/30 -4 JDW 1C/20-4 JDW 1B/20-4 JDW 1A/20-4 JDW 2/20 -4 JDW 1C/10-4 JDW 1B/10-4 JDW 1A/10-4 JDW 2/10 -4 JDW 1C/30-4 JDW 1B/30-4 JDW 1A/30-4 JDW 2/30 -4 JDW 2/20 -4 JDW 1C/30-4 JDW 1B/30-4 JDW 1A/30-4 JDW 2/30 -4 JDW 1A/30-4 JDW 2/30 -4 JDW 2/30 -4 JDW 2/30 -4

HP
0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 1.5 0.70 0.85 1 1.5 1 1.5 1.5 1.5

TOTAL MANOMETRIC HEAD IN METRES 41 37 32 29 25 23 20 18 16 14 45 41 37 33 30 27 24 22 20 18 53 50 46 42 39 37 34 31 29 27 81 75 70 65 61 57 53 50 47 44 28 24 22 21 19 18 16 14 13 12 31 28 26 25 23 21.5 20 18.5 17 16 40 36 34 32 30 28 27 26 24.5 23 67 65 62 60 58 56 54 52.5 51 49 21 20 18 17 16 15.5 15 14 13 12 24 23 22 21 20 19.5 19 18 17 16 30 29 28 27 26 25.5 25 24 23 22 51 50 49 48 47 46 45 44.5 44 43 36 32 27 24 20 17 14 12 38 34 31 28 25 21.5 19 17 14 12 46 42 38 34 31 28 25 22 20 18 74 68.5 63 59 54 50 46 43 40 37.5 58 56 53 51 49 47 45.5 44 42 40 23 19 15 12 25 21 17 14 32 27 22 18 15.5 61 56 51 46.5 42 38 35 32.5 30 25 18.5 14 54 49 45 40 36 33 30 47 42.5 38 34 30 40 35 30 12 16 24 41 11 15 22 47 11.5 15.5 21 42

15

12 20 35 10 13 19 44 11 14 20 41

32.5 30 9 12.5 11.5 18 17 16 42.5 41 39.5 10 9.5 9 13.5 13 12 19.5 18.5 17.5 40 39 38

15 38

14 36

35

32

29

11 17 16 15 37 36.5 36 34.5 33 30.5 29

27

20

16 35 32.5 30 39 36 35

33

32

31

30

30

35 40 45

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


f a
DN2

DN1

a1 h2

TUBO DI ASPIRAZIONE

ALIMENTAZIONE UGELLO

E HS = SUCTION HEIGHT

DN3

SUCTION PORT NOZZLE FEED PORT

EJECTOR

De

a2

TYPE
DN4

Single-phase Three-phase DNp DN1 DN2 DN3 DN4 De JDWm 1C JDWm 1B JDWm 1A JDWm 2 JDW 1C JDW 1B JDW 1A JDW 2 4" 4" 4" 4" 4" 11/4" 11/4" 11/4" 11/4" 11/4" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 96 96 96 96 96

a 69.5 69.5 69.5 75

a1 46 46 46 46 46

a2 148 148 148 148 148

DIMENSIONS mm h h1 h2 n 181 92 201 92 201 92 242 108 181 181 181 207 180 180 180 206

n1

kg* 1~ 3~

FOOT VALVE

DNp

350 350 350 434

144 24 10 15.0 15.0 144 24 10 15.3 15.3 10 144 24 10 16.4 15.4 164 22 10 24.6 22.7 (*weight includes ejector)

69

JDW self-priming pumps for 3" wells


(with immersed ejector)

PERFORMANCE DATA AT n= 2900 1/min

TYPE
Single-phase
JDWm 1C -3 JDWm 1B -3 JDWm 1A -3 JDWm 2 -3 JDWm 1C -3 JDWm 1B -3 JDWm 1A -3 JDWm 2 -3 JDWm 1C -3 JDWm 1B -3 JDWm 1A -3 JDWm 2 -3 JDWm 2 -3 HS = Suction height

POWER
kW
0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 1.1

HS
0 120 240 metres 32 36 28 32 35 56 23 27 30 50 15 19 24 43 34 22 39 30 24 29 32 51 19 24 27 46

FLOW RATE LITRES/HOUR 360 480 600

720

840

960

Three-phase
JDW 1C -3 JDW 1B -3 JDW 1A -3 JDW 2 -3 JDW 1C -3 JDW 1B -3 JDW 1A -3 JDW 2 -3 JDW 1C -3 JDW 1B -3 JDW 1A -3 JDW 2 -3 JDW 2 -3

HP
0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 1.5

TOTAL MANOMETRIC HEAD IN METRES 22 26 29 46 17 21 23 41 18 21 37 17 33 30 19 24 27 42 18 22 25 38 15 19 22 35 17 20 33 17 30

15

39 61 26 30

20

33 55 19 23

25

27 47

36

33

30

39

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f a
DN2
DN1

a1 h2

TUBO DI ASPIRAZIONE

s HS = SUCTION HEIGHT

ALIMENTAZIONE UGELLO

DN3

SUCTION PORT NOZZLE FEED PORT

EJECTOR

De
a2

TYPE
DN4

Single-phase Three-phase DNp DN1 DN2 DN3 DN4 De JDWm 1C JDWm 1B JDWm 1A JDWm 2 JDW 1C JDW 1B JDW 1A JDW 2 4" 4" 3" 4" 4" 11/4" 11/4" 1" 11/4" 11/4" 1" 1" 1" 1" 1" 1" 1" 3/4" 1" 1" 1" 1" 1" 1" 1"

a1 46 46 46 46 46

a2 148 148 130 148 148

DIMENSIONS mm h h1 h2 n 181 92 201 92 201 92 242 108 181 181 181 207 180 180 180 206

n1

kg* 1~ 3~

FOOT VALVE

DNp

96 69.5 96 69.5 70 96 69.5 96 75

350 350 350 434

144 24 10 14.3 14.3 144 24 10 14.6 14.6 10 144 24 10 15.7 14.7 164 22 10 23.9 22.0 (*weight includes ejector)

70

JDW self-priming pumps for 2" wells


(with immersed ejector)

PERFORMANCE DATA AT n= 2900 1/min

TYPE
Single-phase
JDWm 1C -2 JDWm 1B -2 JDWm 1A -2 JDWm 2 -2 JDWm 1C -2 JDWm 1B -2 JDWm 1A -2 JDWm 2 -2 JDWm 1C -2 JDWm 1B -2 JDWm 1A -2 JDWm 2 -2 JDWm 1C -2 JDWm 1B -2 JDWm 1A -2 JDWm 2 -2 JDWm 1B -2 JDWm 1A -2 JDWm 2 -2 JDWm 2 -2 JDWm 2 -2 HS = Suction height

POWER
kW
0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.60 0.75 1.1 1.1 1.1

HS
0 120 240 360 metres 46 50 54 85 34 38 40 71 28 32 35 64 23 27 28 56 21 23 51 41 36 42 46 50 78 29 33 35 63 24 28 31 59 18 22 24 50 15 18 45 36 30 37 42 46 74 24 29 31 58 20 25 28 55 13 18 21 46 15 41 33

FLOW RATE LITRES/HOUR 480 600 720

840

960

1080

1200

Three-phase
JDW 1C JDW 1B JDW 1A JDW 2 JDW 1C JDW 1B JDW 1A JDW 2 JDW 1C JDW 1B JDW 1A JDW 2 JDW 1C JDW 1B JDW 1A JDW 2 JDW 1B JDW 1A JDW 2 JDW 2 JDW 2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2

HP
0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.85 1 1.5 1.5 1.5

TOTAL MANOMETRIC HEAD IN METRES 34 39 43 70 21 26 28 54 18 23 26 51 15 17 42 30 35 39 66 18 23 25 50 15 20 23 47 28 32 36 61 16 21 23 46 13 17 20 43 25 30 34 57 13 18 20 43 14 17 39 22 27 31 53 11 16 18 39 19 24 28 48 14 16 36 17 21 25 44 19 23 40

15

20

34

25

36

30

38

34

31

35 40 45

37

33

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


f a
DN2

h2

a1

E HS = SUCTION HEIGHT

w
DN1

s
SUCTION PORT NOZZLE FEED PORT

n1 n

EJECTOR

a2

De
GASKETS

TYPE
Single-phase Three-phase DNp DN1 JDWm 1C JDW 1C 4" 11/4" JDWm 1B JDW 1B 4" 11/4" 2" 11/4" JDWm 1A JDW 1A 4" 11/4" JDWm 2 JDW 2 4" 11/4" DN2 DN3 De 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" a a1 a2 148 148 123 148 148 96 69.5 46 96 132.5 46 49 96 69.5 46 46 96 138 46

h1

DIMENSIONS mm f h h1 h2 350 460 350 540 181 92 201 92 201 92 242 108 181 181 181 207

n 180 180 180 206

n1 144 144 144 164

w 24 24 24 22

s 10 10 10 10 10

kg* 1~ 3~ 15.9 16.2 17.3 25.5 15.9 16.2 16.3 23.2

DN3
FOOT VALVE

DNp

(*weight includes ejector and adaptor)

71

JET self-priming pumps


stainless steel pump body

RANGE OF PERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 72 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 40C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: stainless steel AISI 304, with threaded ports ISO 228/1. BODY BACK-PLATE: stainless steel AISI 304. EJECTOR ASSEMBLY: technopolymer (approved for drinking water). IMPELLER: technopolymer (for drinking water). MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104 MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.. JCRm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. JCR: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. JCR SELF-PRIMING PUMPS ARE DESIGNED FOR SUCTION LIFTS AND CAN BE POSITIONED ABOVE THE WATER SOURCE, INCLUDING APPLICATIONS WITH AIR ENTRAINED IN THE WATER. DUE TO THEIR RELIABILITY AND LOW MAINTENANCE, THEY ARE RECOMMENDED FOR DOMESTIC USE, INCLUDING WATER DISTRIBUTION (AS PART OF A PRESSURE SET), GARDEN IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.

OPTIONS ON REQUEST

other voltages or frequency 60 Hz

72

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

JCR15H

JCR12H

JCR10H

Head H (metres)

JCR15M JCR1A JCR12M JCR10M

JCR1B JCR1C

Flow rate Q

TYPE
Single-phase JCRm 1C JCRm 1B JCRm 1A JCRm 10H JCRm 12H JCRm 15H JCRm 10M JCRm 12M JCRm 15M Three-phase JCR 1C JCR 1B JCR 1A JCR 10H JCR 12H JCR 15H JCR 10M JCR 12M JCR 15M

POWER
kW HP

m3/h l/min

0 0 35 41 47 56 64 72 46 50 55

0.3 5 32 36 42 50 58 67 44 48 53

0.6 10 27 31 38 45 53 61 41 45 50

0.9 15 24 27 34 41 48 56 39 43 48

1.2 20 21 24 31 37 44 51 37 41 46

1.5 25 19 22 28.5 33 40 47 35 39 43

1.8 30 17 20 26 30 36 43 32 37 41

2.1 35 16 19 24 27 33 40 30 36 39

2.4 40 15 17 22 25 31 37 28 34 37

3.0 50 13 15 19 22 26 32 25 30 34

3.6 60

4.2 70

4.8 80

0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1

0.50 0.70 0.85 1 1.25 H metres 1.5 1 1.25 1.5

22 27 31

21 25 29

19 23 27

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


f a
DN2

h2 h h1
DN1

n1

TYPE Single-phase Three-phase JCRm 1C JCR 1C JCRm 1B JCR 1B JCRm 1A JCR 1A JCRm 10H-M JCR 10H-M JCRm 12H-M JCR 12H-M JCRm 15H-M JCR 15H-M

PORTS
DN1 DN2

1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4"

1" 1" 1" 1" 1" 1" 1" 1"

a 90 90 90 90 117 117 117 117

f 345 345 345 353/345 406 406 406

h 174 174 174 174 206 206 206

DIMENSIONS mm h1 h2 n 122 52 160 122 52 160 122 52 160 145 55 184 145 55 184 184 145 55 184

kg n1 120 120 120 135 135 135 w 95 95 95 110 110 110 110 s 9 9 9 10 10 10 1~ 5.6 5.7 6.9 9.4 10.5 10.8 3~ 5.8 6.0 6.5 9.6 9.6 10.4

73

self-priming multi-stage pumps

New self-priming pumps, quietrunning, reliable, high efficiency, patented.

RANGE OF PERFORMANCE Flow rate up to 200 l/min (12 m3/h) Head up to 120 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 40C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron and stainless steel AISI 304 (cast iron up to 0.75 kW), with threaded ports ISO 228/1. IMPELLER: technopolymer (approved for drinking water). MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104 MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. PLURIJETm: single-phase 230 V - 50 Hz with capacitor nd thermal overload protector. PLURIJET: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL.

INSTALLATION AND USE


They are recommended for clean water and liquids that are chemically non aggressive to the materials from which the pump is made. PLURIJET SELF-PRIMING PUMPS ARE DESIGNED FOR LIFTING WATER, EVEN IN CASES WITH ENTRAINED AIR. THEIR QUIET RUNNING, RELIABILITY AND LOW POWER CONSUMPTION MAKES THEM PARTICULARLY SUITABLE FOR DOMESTIC AND CIVIL USE, INCLUDING PRESSURISATION AND DISTRIBUTION OF WATER, IRRIGATION AND RAINWATER RECOVERY SYSTEMS. The pumps must be installed in enclosed places, or at least protected against inclement weather.

OPTIONS ON REQUEST

version in stainless steel EN 10088-3 - 1.4401 (AISI 316) other voltages or frequency 60 Hz

74

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PLURIJET 6/90

5/90

Head H (metres)

4/80 3/80

Flow rate Q

TYPE
Single-phase
PLURIJETm 3/80 PLURIJETm 4/80 PLURIJETm 5/90 PLURIJETm 6/90

POWER
kW HP

m3/h l/min

0 0 38 50 83 100

0.3 5 36 48 82 99

0.6 10 34.5 46.5 80 96

1.2 20 32 43 76 91.5

1.8 30 29 38.5 71 85

2.4 40 25 33.5 65 78

3.0 50 20 28 59 71

3.6 60 15.5 22.5 53 64

4.2 70 10.5 16.5 47 56

4.8 80 5 10 40 48

Three-phase
PLURIJET 3/80 PLURIJET 4/80 PLURIJET 5/90 PLURIJET 6/90

0.45 0.60 1.1 1.5

0.60 0.85 H metres 1.5 2

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

PLURIJET 80
f a
DN2

PLURIJET 90
n
DN2

DN1

h2

h2

DN1

h1 h

s a w

h1

s n1

TYPE Single-phase Three-phase

PORTS
DN1 DN2

PLURIJETm 3/80 PLURIJETm 4/80 PLURIJETm 5/90 PLURIJETm 6/90

PLURIJET 3/80 PLURIJET 4/80 PLURIJET 5/90 PLURIJET 6/90

1" 1" 1" 11/4" 11/4" 11/4"

1" 1" 1" 1" 1" 1"

a 110 135 69 69 69

f 334 367/359 634 665

h 172 172 172 234 230 234

DIMENSIONS mm h1 h2 n 134 38 158 134 158 38 134 38 158 166 46 185 153 46 185 166 46 185

kg n1 116 116 116 145 145 145 w 2 2 2 304 335 s 9 9 9 10 10 10 1~ 9.4 10.8 25.5 27.5 3~ 8.9 10.2 23.5 27.0

75

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PLURIJET 6/130

5/130

Head H (metres)

4/130

3/130 4/100 3/100

Flow rate Q

TYPE
Single-phase
PLURIJETm 3/100 PLURIJETm 4/100 PLURIJETm 3/130 PLURIJETm 4/130 PLURIJETm 5/130

POWER
kW HP

m3/h l/min

0 0 36 46 50 66 83 100

0.3 5 35.5 45 49.5 66 82.5 99

0.6 10 35 43 49 65 81 98

1.2 20 33.5 42 48 64 80 96

1.8 30 32 40 47 62 78 94

2.4 40 30 38 45.5 60.5 75.5 91

3.0 50 28 35.5 44 58.5 73 88

3.6 60 26 33 42.5 56.5 70.5 85

4.2 70 23 30 40.5 54 67.5 81

4.8 80 20 26.5 38.5 51 64 77

6.0 100 13.5 19 34 45 56.5 68

7.2 120 5 10 28 37 46.5 56

7.8 130 5 25 33 41 50

Three-phase
PLURIJET 3/100 PLURIJET 4/100 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130

0.60 0.75 1.1 1.5 1.8 2.2

0.85 1 1.5 H metres 2 2.5 3

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

PLURIJET 100

PLURIJET 130

f a
DN2

n
DN2

h2

h2

DN1

DN1

n1

h1

h1

s n1

TYPE Single-phase Three-phase

PORTS
DN1 DN2

PLURIJETm 3/100 PLURIJET 3/100 PLURIJETm 4/100 PLURIJET 4/100 PLURIJETm 3/130 PLURIJET 3/130 PLURIJETm 4/130 PLURIJET 4/130 PLURIJETm 5/130 PLURIJET 5/130 PLURIJET 6/130

1" 1" 1" 11/4" 11/4" 11/4"" 1/4 1 11/4"

1" 1" 1" 1" 1" 1" 1" 1"

a 110 135 69 69 69 69 69

f 342/334 378 571 602 634 665

h 172 191 234 234 230 234 234

DIMENSIONS mm h1 h2 n 134 38 158 134 158 134 61 158 166 46 185 166 46 185 153 46 185 166 46 185 166 46 185

kg n1 116 116 116 145 145 145 145 145 w 2 2 2 241 272 304 335 s 9 9 9 10 10 10 10 10 1~ 10.2 13.4 23.5 25.9 27.5 3~ 9.4 12.3 21.6 25.0 27.0 29.0

76

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PLURIJET 6/200

5/200

Head H (metres)

4/200

3/200

Flow rate Q

TYPE
Single-phase Three-phase
PLURIJETm 3/200 PLURIJET 3/200 PLURIJETm 4/200 PLURIJET 4/200 PLURIJETm 5/200 PLURIJET 5/200 PLURIJET 6/200

POWER
kW HP

m3/h l/min

0 0 45 60 75 90

1.2 20 44 58 73 88

2.4 40 43 57 71.5 86

3.0 50 42 56 70 84

3.6 60 41 54.5 68 82

4.8 80 39 52 65 78

6.0 100 36 48 60 72

7.2 120 32.5 43 54 65

8.4 140 29 38.5 48 58

9.6 160 25 33 41.5 50

10.8 180 20 26.5 33 40

12.0 200 15 20 25 30

1.1 1.5 1.8 2.2

1.5 2 2.5 3

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f
DN2

h2

DN1

h1

s n1

TYPE Single-phase Three-phase

PORTS
DN1 DN2

PLURIJETm 3/200 PLURIJET 3/200 PLURIJETm 4/200 PLURIJET 4/200 PLURIJETm 5/200 PLURIJET 5/200 PLURIJET 6/200

11/4" 11/4" 11/4" 11/4" 11/4"

1" 1" 1" 1" 1"

a 69 69 69 69 69

f 571 602 634 665

h 234 234 230 234 234

DIMENSIONS mm h1 h2 n 166 46 185 166 46 185 153 46 185 166 46 185 166 46 185

kg n1 145 145 145 145 145 w 241 272 304 335 s 10 10 10 10 10 1~ 23.5 25.9 27.5 3~ 21.6 25.0 27.0 29.0

77

self-priming liquid ring pumps

RANGE OF PERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 51 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 90C (+55C for diesel fuel) Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our genera terms of sale. CONSTRUCTION CHARACTERISTICS


INSTALLATION AND USE


THEY ARE RECOMMENDED FOR PUMPING DIESEL FUEL, CLEAN WATER WITHOUT ABRASIVE PARTICLES AND LIQUIDS THAT ARE CHEMICALLY NON AGGRESSIVE TO THE MATERIALS FROM WHICH THE PUMP IS MADE. DUE TO THEIR OPERATING PRINCIPLE, THEY ARE IDEAL WHERE A COMPACT SELF-PRIMING PUMP IS NEEDED OR WHERE LIQUID SUPPLY IS IRREGULAR OR CONTAINS AIR. The pumps must be installed in enclosed places, or at least protected against inclement weather.

PUMP BODY: cast iron, with threaded ports ISO 228/1. MOTOR BRACKET (patent n 1289150): aluminium with brass insert; reduces starting difficulties due to seizure of the impeller after long periods of inactivity. IMPELLER: brass of the star type with open radial vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - VITON. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. CKm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. CK: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL

OPTIONS ON REQUEST

CKm/INT version with switch and power cable with Schuko plug CKm 50-BP/NZ aluminium trigger dispensing nozzle and 4 metre spiral reinforced hose. special mechanical seal other voltages or frequency 60 Hz protection IP 55

78

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

CK90E CK80E

Head H (metres)

CK50

CK50BP

Flow rate Q

TYPE
Single-phase CKm 50 CKm 50-BP CKm 80-E CKm 90-E Three-phase CK 50 CK 50-BP CK 80-E CK 90-E

POWER
kW HP

m3/h l/min

0 0 35 20 48 51

0.3 5 31 20 46 49

0.6 10 27 20 42 45

0.9 15 24 20 38 41

1.2 20 20 20 34 37

1.5 25 16 16.5 30 33

1.8 30 13 13 26 29

2.1 35 9 9 22 25

2.4 40 5 5 18 21

3.0 50

0.37 0.25 0.60 0.75

0.50 0.33 H metres 0.85 1

10 13

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

i
DN2

h2

DN1

h3

h1

n1 n

TYPE Single-phase Three-phase CKm 50 CKm 50-BP CKm 80-E CKm 90-E CK 50 CK 50-BP CK 80-E CK 90-E

PORTS
DN1 DN2

3/4" 3/4" 3/4" 1" 1" 1"

3/4" 3/4" 3/4" 1" 1" 1"

a 41 44 50 50 50

f 260 263 296 296 296

h 159 159 159 179 179 179

h1 128 128 128 136 136 136

h2 25 25 25 31 31 31

DIMENSIONS mm h3 i 153 75 153 75 153 75 167 81 167 81 167 81

kg m 80 80 80 90 90 90 n 120 120 120 134 134 134 n1 100 100 100 112 112 112 w 69 69 69 77 77 77 s 7 7 7 7 7 1~ 7.3 7.3 7.3 11.6 11.8 3~ 6.8 6.8 6.8 10.8 11.0

79

self-priming liquid ring pumps


with double anti-seize inserts

Dependable priming and starting, even after long periods without use, thanks to anti seize inserts which prevent rusting around the impeller.

RANGE OF PERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 54 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 90C (+55C for diesel fuel) Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


INSTALLATION AND USE


THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER OR LIQUIDS WITHOUT ABRASIVE PARTICLES AND LIQUIDS THAT ARE CHEMICALLY NON AGGRESSIVE TO THE MATERIALS FROM WHICH THE PUMP IS MADE. DUE TO THEIR OPERATING PRINCIPLE, THEY ARE IDEAL WHERE A COMPACT SELF-PRIMING PUMP IS NEEDED OR WHERE LIQUID SUPPLY IS IRREGULAR OR CONTAINS AIR. The pumps must be installed in enclosed places, or at least protected against inclement weather.

PUMP BODY: cast iron with stainless steel insert to prevent the impeller seizing due to rust. Inlet ports threaded to ISO 228/1. MOTOR BRACKET (patent n 1289150): aluminium with brass insert; eliminates starting difficulties due to seizure of the impeller after long periods of inactivity. IMPELLER: brass of the star type with open radial vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - VITON. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty.. CKRm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector. CKR: three-phase 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44. REGISTERED MODEL

OPTIONS ON REQUEST

CKRm/INT version with switch and power cable with Schuko plug special mechanical seal other voltages or frequency 60 Hz protection IP 55

80

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Flow rate Q

TYPE
Single-phase CKRm 80-E CKRm 90-E CKRm 100-E Three-phase CKR 80-E CKR 90-E CKR 100-E

POWER
kW HP

m3/h l/min

0 0 48 51 54

0.3 5 46 49 52

0.6 10 42 45 48

0.9 15 38 41 44

1.2 20 34 37 40

1.5 25 30 33 36

1.8 30 26 29 32

2.1 35 22 25 28

2.4 40 18 21 24

3.0 50 10 13 16

0.60 0.75 0.90

0.85 1 H metres 1.25

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

i
DN2

h2

DN1

h3

h1

n1 n

TYPE Single-phase Three-phase CKRm 80-E CKR 80-E CKRm 90-E CKR 90-E CKRm 100-E CKR 100-E

PORTS
DN1 DN2

1"

1"

1"
1"

1"
1"

a 50 50 50

f 296 296 296

h 179 179 179

h1 136 136 136

h2 31 31 31

DIMENSIONS mm h3 i m 167 81 90 167 81 90 167 81 90

kg n 134 134 134 n1 112 112 112 w 77 77 77 s 7 7 7 1~ 11.6 11.8 11.8 3~ 10.8 11.0 12.0

81

standardised centrifugal pumps to EN 733 - DIN 24255

New patented motor design, high efficiency class EFF1, for maximum energy saving.

RANGE OF PERFORMANCE Flow rate up to 6000 l/min (360 m3/h) Head up to 95 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature from -10C to + 90C Environment temperature from -10C to + 40C Max. pressure in the pump body 10 bar (PN10) CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. THIS SERIES IS SUITABLE FOR SUPPLYING AND MOVING WATER, IN COOLING, HEATING, CIRCULATING AND CONDITIONING SYSTEMS, FOR FIRE FIGHTING, IRRIGATION, INDUSTRIAL AND AGRICULTURAL APPLICATIONS. Manifacture in accordance with dimensional standards EN 733 - DIN 24255 ensures models are fully interchangeable.The design allows the pump body to be removed without disconnecting it from the pipes (back pull out). The pumps must be installed in enclosed places, or at least protected against inclement weather.

PUMP BODY: cast iron, complies with dimensional standards EN 733 - DIN 24255 and UNI 7467-NF E-44-111, with flanged suction and delivery ports complete with threaded steel counterflanges. BODY BACK-PLATE: cast iron. IMPELLER: brass for models F32/160, F32/200, F40/160, F40/200, F50/125 e F50/160. IMPELLER: cast iron for models F40/250, F50/200, F50/250, F65/125, F 65/160, F65/200, F80/160, F100/160 MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are close-coupled to a carefully matched PEDROLLO electric motor, asynchronous type with high efficiency (class EFF1 for powers from 4 to 22 kW), quiet running, totally enclosed fan cooled (TEFC), suitable for continuous duty. Fm: single-phase 230 V - 50 Hz with capacitor and thermal overload protector (up to 1.5 kW). F: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 22 kW. INSULATION: class F. PROTECTION: IP 44.

OPTIONS ON REQUEST

pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal other voltages or frequency 60 Hz protection IP 55 for liquids with higher or lower temperatures for environments with higher or lower temperatures

82

RANGE OF PERFORMANCE AT n= 2900 1/min

Head H (m)

20

Flow rate Q

83

DN1= 50 DN2= 32

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

F32/160A

55 60 63

F32/160B

Head H (metres)

=65.5%
63

F32/160C
60

55

NPSH (metres)

Absorbed power P2 (kW)

B C

Flow rate Q

TYPE
Single-phase Fm 32/160C Fm 32/160B Fm 32/160A Three-phase F 32/160C F 32/160B F 32/160A

POWER
kW HP Q

m3/h l/min

0 0 25

6 100 24 30 37

9 150 23 29 36

12 200 21 28 34

15 250 19 26 32

18 300 16 23.5 30

21 350 13 20 27.5

24 400

27 450

1.5 2.2 3

2 3 4

H metres

31 38

16 24 20

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

84

P2 (HP)

NPSH (feet)

H (feet)

DN1= 50 DN2= 32

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase F 32/200C F 32/200B F 32/200A

POWER
kW HP Q

m3/h l/min

0 0 46

6 100 44 52 57

9 150 43 50.5 56.5

12 200 41.5 49 56

15 250 40 47 55

18 300 38 45 53

21 350 36 43 52

24 400 34 41 50

27 450 31.5 38.5 47

30 500

4 5.5 7.5

5.5 7.5 10

H metres

54 60

36 44

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

85

DN1= 50 DN2= 32

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Single-phase Fm 32/200BH Three-phase F 32/200BH F 32/200AH

POWER
kW HP

m3/h l/min

0 0 49 59

6 100 45 55

9 150 42 52

12 200 39 49

15 250 34 44

18 300 28 38

3 4

4 5.5

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

86

P2 (HP)

NPSH (feet)

H (feet)

DN1= 65 DN2= 40

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Single-phase Fm 40/160C Fm 40/160B

POWER
HP Q

m3/h l/min

0 0 27

6 100 27 32 38

9 150 26.5 31.5 37.8

12 200 26 31 37

15 250 25.5 30.5 36.5

18 300 25 30 36

24 400 22.5 27.5 33.5

30 500 19 24 30

36 600 14 20 26

42 700

Three-phase kW F 40/160C 2.2 F 40/160B 3 F 40/160A 4

3 4 5.5

H metres

32 38

20

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

87

DN1= 65 DN2= 40

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase F 40/200B F 40/200A

POWER
kW HP Q

m3/h l/min

0 0 48 56

6 100 47 55

9 150 46.5 55

12 200 46

15 250 45.5

18 300 44.5

24 400 42

30 500 38

36 600 34

42 700 28

5.5 7.5

7.5 H metres 10

Q = Flow rate H = Total manometric head

55 54.5 54 52.5 49.5 46 41 Tolerance of the performance curves according to EN ISO 9906 App. A.

88

P2 (HP)

NPSH (feet)

H (feet)

DN1= 65 DN2= 40

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase F 40/250C F 40/250B F 40/250A

POWER
kW HP Q

m3/h l/min

0 0 64 71 88

6 100 64 71 88

9 150 63.5 70.5 87.5

12 200 63 70 87

15 250 62.5 69.5 86.5

18 300 62 69 86

24 400 60 67 84

30 500 56.5 64 81

36 600 52.5 60 77

42 700 47 55 72

9.2 11 15

12.5 15 H metres 20

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

89

DN1= 65 DN2= 50

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Fm 50/125C F 50/125C Fm 50/125B F 50/125B F 50/125A

POWER
HP Q

m3/h l/min

0 0 18.5

18 300 17.5 20.7 23.5

24 400 17 20 23

30 500 16.5 19.5 22.5

36 600 15.5 18.8 21.8

42 700 14.8 17.8 20.8

48 800 13.5 16.5 19.5

54 900 12 15 18.3

60 1000 10.5 13.5 16.8

66 1100 8.2 11.2 15

72 1200 6 9 13

Single-phase Three-phase kW 2.2 3 4

3 4 5.5

H metres 21.5 24.5

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

90

P2 (HP)

NPSH (feet)

H (feet)

DN1= 65 DN2= 50

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase F 50/160C F 50/160B F 50/160A

POWER
kW HP Q

m3/h l/min

0 0 27 33 38

18 300 27 32 37

24 400 26.5 31.7 36.8

30 500 25 31 36.5

36 600 24.5 30 36

42 700 23 29 34

48 800 20 27 33

54 900 18.5 26 32

60 1000 16 24 30

66 1100 21 27

4 5.5 7.5

5.5 7.5 10

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

91

DN1= 65 DN2= 50

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase F 50/200C F 50/200B F 50/200A F 50/200AR

POWER
kW HP

m3/h l/min

24 400 44 52 61 69

36 600 44 52 61 69

48 800 44 52 60.5 68.5

60 1000 42 50 60 68

72 1200 39 47 57 65

84 1400 36 44 54 62

96 1600 33 40 50 58

102 1700 30 38 48 56

108 1800

11 15 18.5 22

15 20 25 30

H metres

45 53

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

92

P2 (HP)

NPSH (feet)

H (feet)

DN1= 65 DN2= 50

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

F50/250AR
48 51 52 54 55 58 59 =59%

F50/250A

60

F50/250B

Head H (metres)

F50/250C

F50/250D
57

54 52

NPSH (metres)

Absorbed power P2 (kW)

AR A

C D

Flow rate Q

TYPE
Three-phase F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR

POWER
kW HP

m3/h l/min

0 0 51 59 72 85 95

18 300 51 59 72 85 95

24 400 49 58 71 84 94

30 500 47 57 70 83 93

36 600 44 54 69 82 92

42 700 41 51 67 80 90

48 800 37 47 65 78 88

54 900 32 42 62 76 86

60 1000

9.2 11 15 18.5 22

12.5 15 20 H metres 25 30

59 73 83

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

93

DN1= 80 DN2= 65

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

F65/125A

78

83 87 87.5 =88%

87.5

Head H (metres)

F65/125B

F65/125C

NPSH (metres)

Absorbed power P2 (kW)

B C

Flow rate Q

TYPE
Three-phase F 65/125C F 65/125B F 65/125A

POWER
kW HP Q

m3/h l/min

0 0 16 18 23

36 600 16 18 23

48 800 16 18 23

60 1000 15.5 18 23

72 1200 14.5 17 22.5

84 1400 13.5 16.5 22.5

96 1600 12.5 15.5 22

108 1800 11 14.5 21

120 2000 13 19.5

132 2200

4 5.5 7.5

5.5 7.5 10

H metres

18

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

94

P2 (HP)

NPSH (feet)

H (feet)

87

DN1= 80 DN2= 65

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

F65/160A F65/160B

60

65

70

75

78 80 =81%

Head H (metres)

80 78

NPSH (metres)

Absorbed power P2 (kW)

B C

Flow rate Q

TYPE
Three-phase F 65/160C F 65/160B F 65/160A

POWER
kW HP Q

m3/h l/min

0 0 32 37 41

36 600 32 36.5 40.5

48 800 32 36.5 40.5

60 1000 32 36 40

72 1200 32 35.5 35.5

84 1400 30 34 39

96 1600 29 33 37.5

108 1800 27 31 36

120 2000 25 29 34

132 2200 22 26 31

144 2400

9.2 11 15

12.5 15 H metres 20

23 28

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

F65/160C

95

DN1= 80 DN2= 65

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

F65/200AR

60 65 71 73 74 76

F65/200A

=79%

76

Head H (metres)

74 73

F65/200B

71

NPSH (metres)

Absorbed power P2 (kW)

AR A B

Flow rate Q

TYPE
Three-phase F 65/200B F 65/200A F 65/200AR

POWER
kW HP Q

m3/h l/min

24 400 45 51 57

36 600 45 51 57

48 800 45 51 57

60 1000 45 51 57

72 1200 44 50 56

84 1400 42.5 49 55

96 1600 41 47 53

108 1800 38.5 44.5 50.5

120 2000 35.5 41.5 47.5

126 2100 40 46

15 18.5 22

20 25 30

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

96

P2 (HP)

NPSH (feet)

H (feet)

DN1= 100 DN2= 80

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase F 80/160D F 80/160C F 80/160B F 80/160A

POWER
kW HP

m3/h l/min

0 0 25 30 35 40

30 500 25 30 35 40

60 1000 25 30 35 40

90 1500 24.5 29.5 34.5 39.5

120 2000 23.5 28.5 33.5 38.5

150 2500 21 26 31 36

180 3000 18 23 28 33

210 3500 14.5 19.5 24.5 29.5

240 4000 10 15 20 25

11 15 18.5 22

15 20 25 30

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

P2 (HP)

NPSH (feet)

H (feet)

97

DN1= 125 DN2= 100

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

NPSH (metres)

Absorbed power P2 (kW)

Flow rate Q

TYPE
Three-phase F 100/160C F 100/160B F 100/160A

POWER
kW HP Q

m3/h l/min

0 0 28

60 1000 28 32 35

120 2000 25.5 30 34

180 3000 22 27 31

240 4000 17.5 22.5 27

270 4500 15 19.5 24.5

300 5000 12 17 22

330 5500

360 6000

15 18.5 22

20 25 30

H metres

32 35

13 18 15

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

98

P2 (HP)

NPSH (feet)

H (feet)

DIMENSIONS AND WEIGHTS


f a
DN2

h2
DN1

w1 w2

n1 n2

TYPE Single-phase Three-phase Fm 32/160C F 32/160C Fm 32/160B F 32/160B Fm 32/160A F 32/160A F 32/200C F 32/200B F 32/200A Fm 32/200BH F 32/200BH F 32/200AH Fm 40/160C F 40/160C Fm 40/160B F 40/160B F 40/160A F 40/200B F 40/200A F 40/250C F 40/250B F 40/250A Fm 50/125C F 50/125C Fm 50/125B F 50/125B F 50/125A F 50/160C F 50/160B F 50/160A F 50/200C F 50/200B F 50/200A F 50/200AR F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR F 65/125C F 65/125B F 65/125A F 65/160C F 65/160B F 65/160A F 65/200B F 65/200A F 65/200AR F 80/160D F 80/160C F 80/160B F 80/160A F 100/160C F 100/160B F 100/160A

PORTS
DN1 DN2

50 50 50 50 50 50 50 50 50 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 80 80 80 80 80 80 80 80 80 80 100 100 100 100 100 125 125 125 125

32 32 32 32 32 32 32 32 32 40 40 40 40 40 40 40 40 40 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 65 65 65 65 65 65 65 65 65 65 80 80 80 80 80 100 100 100 100

a 80 80 80 80 80 80 80 80 80 80 80 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 125 125 125 125 125 125 125

f 412 431/412 465/431 469 515 515 515 469 469 469 431/412 465/431 465 535 535 535 606 606 606 701 450/431 484/450 484 489 535 535 535 616 711 711 711 743 606 606 606 701 701 701 733 511 557 557 557 621 621 621 716 719 719 719 751 652 747 747 747 779 758 758 758 790

h 292 292 292 340 340 340 340 340 292 292 292 340 340 340 405 405 405 292 292 292 340 340 340 360 360 360 360 360 405 405 405 405 405 340 340 340 360 360 360 405 405 405 405 405 405 405 480 480 480

h1 132 132 132 160 160 160 160 160 132 132 132 160 160 160 180 180 180 132 132 132 160 160 160 160 160 160 160 160 160 180 180 180 180 180 160 160 160 160 160 160 180 180 180 180 180 180 180 200 200 200

DIMENSIONS h2 n 160 242 160 242 160 242 180 270 180 270 180 270 180 270 180 270 160 240 160 240 160 240 180 275 180 275 180 275 225 328 225 328 225 328 160 242 160 242 160 242 180 269 180 269 180 269 200 316 200 316 200 316 200 316 200 316 225 337 225 337 225 337 225 337 225 337 180 291 180 291 180 291 200 300 200 300 200 300 225 340 225 340 225 340 225 330 225 330 330 225 330 225 330 280 362 280 362 280 362
DN

mm n1 190 190 190 190 190 190 190 190 190 190 190 190 212 212 212 250 250 250 190 190 190 212 212 212 212 212 212 212 250 250 250 250 250 212 212 212 212 212 212 212 250 250 250 250 250 250 250 280 280 280

h1

kg* n2 240 240 240 240 240 240 240 240 240 240 240 240 265 265 265 320 320 320 240 240 240 265 265 265 265 265 265 265 320 320 320 320 320 280 280 280 280 280 280 280 320 320 320 320 320 320 320 360 360 360
DN

w1 35 35 35 35 35 35 35 35 35 35 35 35 35 47.5 47.5 47.5 35 35 35 35 35 35 35 35 35 35 35 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 60 60 60

w2 35 35 35 35 35 35 35 35 35 35 35 35 35 47.5 47.5 47.5 35 35 35 35 35 35 35 35 35 35 35 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 60 60 60

s 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 18 18 18

1~ 39.2 42.6 49.2 53.8 43.9 50.5 44.2 50.5 -

3~ 38.4 39.2 42.6 52.1 57.0 63.0 48.5 52.8 41.2 43.9 50.5 61.4 65.9 108.0 115.0 132.0 41.4 44.2 50.5 55.5 60.5 65.0 105.3 121.7 134.2 145.7 111.0 118.0 135.0 148.0 159.5 62.0 67.7 72.0 100.0 107.0 123.0 128.0 141.5 153.0 112.5 129.5 142.5 154.0 141.2 153.7 165.2

(*weight includes counterflanges)

DN FLANGES mm
32 40 50 65 80 100 125

t mm
140 150 165 185 200 220 250

u mm
100 110 125 145 160 180 210

N
4 4 4 18 8 8 8 8

HOLES (mm)
18 18 18 18 18

u t

u t

99

pumps with bronze body

RANGE OF PERFORMANCE Flow rate up to 90 l/min (5.4 m3/h) Head up to 55 m. LIMITS OF USE Liquid temperature up to + 90C Environment temperature up to + 40C

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. THE NON-FERROUS CONSTRUCTION GUARANTEES AGAINST RUST AND OXIDATION. THE COMPACT DESIGN AND HYDRAULIC CHARACTERISTICS SUIT INDUSTRIAL APPLICATIONS INCLUDING COOLING AND CONDITIONING SYSTEMS. The pumps must be installed in enclosed places, or at least protected against inclement weather.

PUMP BODY: bronze, with threaded ports ISO 228/1. MOTOR BRACKET (patent n 1289150) PK-Bz, PQ-Bz: aluminium with brass front insert. BODY BACK-PLATE: CP-Bz: stainless steel AISI 316. IMPELLER: PK-Bz, PQ-Bz: brass. CP-Bz: stainless steel AISI 316 MOTOR SHAFT: stainless steel AISI 316. MECHANICAL SEAL: ceramic - graphite - VITON. ELECTRIC MOTOR: induction motor, for continuous duty. Single-phase: 230 V - 50 Hz with capacitor and thermal overload protector. Three-phase: 230/400 V - 50 Hz. INSULATION: class F. PROTECTION: IP 44.

OPTIONS ON REQUEST

special mechanical seal other voltages or frequency 60 Hz protection IP 55 for liquids with higher temperatures for environments with higher temperatures

100

CURVES AND PERFORMANCE DATA AT n= 2900 1/min


1 1 2 2 3 3 4 4 5 6 5 7 6 8 7 9 8 10 9 11 12 10 13 11

PK65Bz

PK60Bz

Head H (metres)

Flow rate Q

TYPE
Single-phase PKm 60-Bz PKm 65-Bz Three-phase PK 60-Bz PK 65-Bz

POWER
kW HP

m3/h l/min

0 0 40 55

0.3 5 38 50

0.6 10 33.5 45.5

0.9 15 29 40.5

1.2 20 24 36

1.5 25 19.5 31

1.8 30 15 27

2.1 35 10 22

2.4 40 5 17

3.0 50 8

0.37 0.50

0.50 H metres 0.70

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f
DN2

h2

DN1

h3

h1

n1 n

TYPE Single-phase Three-phase PKm 60-Bz PK 60-Bz PKm 65-Bz PK 65-Bz

PORTS
DN1 DN2

1" 1" 1"

1" 1" 1"

a 42 48

f 243 258/250

h 152 152 152

h1 63 63 63

h2 75 80

DIMENSIONS mm h3 i m 138 20 80 20 80 143 20 80

kg n 120 120 120 n1 100 100 100 w 55 55 55 s 7 7 7 1~ 5.7 8.1 3~ 5.7 6.8

101

CURVES AND PERFORMANCE DATA AT n= 2900 1/min


1 1 2 2 3 3 4 4 5 6 5 7 6 8 7 9 8 10 9 11 12 10 13 11

PQ65Bz

PQ60Bz

Head H (metres)

Flow rate Q

TYPE
Single-phase PQm 60-Bz PQm 65-Bz Three-phase PQ 60-Bz PQ 65-Bz

POWER
kW HP

m3/h l/min

0 0 40 55

0.3 5 38 50

0.6 10 33.5 45.5

0.9 15 29 40.5

1.2 20 24 36

1.5 25 19.5 31

1.8 30 15 27

2.1 35 10 22

2.4 40 5 17

3.0 50 8

0.37 0.50

0.50 H metres 0.70

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

f
DN2

h2
DN1

h3

h1

s a w m

n1 n

TYPE Single-phase Three-phase PQm 60-Bz PQ 60-Bz PQm 65-Bz PQ 65-Bz

PORTS
DN1 DN2

1" 1" 1"

1" 1" 1"

a 22 22 22

f h 223 152 152 234/227 152

h1 108 113

h2 30 30 30

DIMENSIONS mm h3 i m 138 78 80 78 80 143 78 80

kg n 120 120 120 n1 100 100 100 w 55 57 s 7 7 7 1~ 5.5 7.4 3~ 5.5 6.6

102

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

CP158Bz

Head H (metres)

CP130Bz

Flow rate Q

TYPE
Single-phase CPm 130-Bz CPm 158-Bz Trifase CP 130-Bz CP 158-Bz

POWER
kW HP

m3/h l/min

0 0 23 36

0.6 10 22 34

1.2 20 21 33.5

1.8 30 20 33

2.4 40 19 32.5

3.0 50 18 31.5

3.6 60 17 30

4.2 70 15.5 28.5

4.8 80 14 27

5.4 90 25

0.37 0.75

0.50 H metres 1

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


f a
DN2

h2
DN1

w n1

TYPE Single-phase Three-phase CPm 130-Bz CPm 158-Bz CP 130-Bz CP 158-Bz

PORTS
DN1 DN2

a 42 42 42

f 259 285

h 205 240

h1 82 92

DIMENSIONS mm h2 n 123 148 165 190

h1

kg n1 135 160 w 41 38 s 10 10 10 1~ 8.5 12.8 3~ 8.3 12.3

1" 1" 1"

1" 1" 1"

103

portable self-priming pumps

RANGE OF PERFORMANCE Flow range up to 50 l/min (3 m3/h) Head up to 70 m LIMITS OF USE Manometric suction lift up to 9 m Liquid temperature up to + 40C Environment temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: BETTY: cast iron; BETTYNOX: stainless steel AISI 304. BETTY 60, 65, 70, 80: CHECK FLAP VALVE built into the suction port. IMPELLER: BETTY 60, 65, 70, 80: brass, type with radial peripheral vanes; BETTY 1, 2, 3 BETTYNOX: technopolymer, centrifugal type. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: induction motor, for continuous duty. Single-phase: 230 V - 50 Hz with capacitor and thermal overload protector. INSULATION: class F. PROTECTION: IP 44.

INSTALLATION AND USE


PORTABLE SELF-PRIMING PUMPS CAPABLE OF CLEARING ENTRAINED AIR FROM THE SUCTION PIPE. RECOMMENDED FOR GARDENING, VEGETABLE GARDENS, WASHING AND HOBBY APPLICATIONS THEY ARE SUITABLE FOR USE WITH ANY LIQUIDS COMPATIBLE WITH THE MATERIALS OF CONSTRUCTION.

STANDARD FEATURES: BETTY Carrying handle.


Hosetails 20 mm. 1.5 m power cable with Schuko plug.

104

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

BETTY 80 BETTY 70

BETTY 65

Head H (metres)

BETTY 60

Flow rate Q

TYPE
Single-phase BETTY 60 BETTY 65 BETTY 70 BETTY 80

POWER
kW HP

m3/h l/min

0 0 40 55 65 70

0.3 5 38 50 62 66

0.6 10 33.5 45.5 57 61

0.9 15 29 40.5 52 56

1.2 20 24 36 47 51

1.5 25 19.5 31 42 46

1.8 30 15 27 37 41

2.1 35 10 22 32 36.5

2.4 40 5 17 27 31

2.7 45 12.5 22 27

3.0 50 8 18 22

0.37 0.50 0.60 0.75

0.50 0.70 H metres 0.85 1

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

n1
2

h1

DN1

DN2

TYPE Single-phase BETTY 60 BETTY 65 BETTY 70 BETTY 80

PORTS
DN1 DN2

1 20

2 20

1" 1" 1 1" 1"

1" 1" 1 1" 1"

f 270 270 270 277 277 277

DIMENSIONS mm h h1 273 267 273 267 267 273 273 267 273 267

kg n 220 220 220 220 220 n1 160 160 160 160 160 7.9 9.5 12.6 12.8

105

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

BETTY 3

BETTY 2

BETTY 1

Head H (metres)

Flow rate Q

TYPE
Single-phase BETTY 1 BETTY 2 BETTY 3

POWER
kW HP

m3/h l/min

0 0 35 41 47

0.3 5 32 36 42

0.6 10 27 31 38

0.9 15 24 27 34

1.2 20 21 24 31

1.5 25 19 22 28.5

1.8 30 17 20 26

2.1 35 16 19 24

2.4 40 15 17 22

2.7 45 14 16 21.5

3.0 50 13 15 19

0.37 0.50 0.60

0.50 0.70 H metres 0.85

Q = Flow rate H = Total manometric head Hs = Suction height

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

h1

DN1

DN2

f1 f n

TYPE Single-phase BETTY 1 BETTY 2 BETTY 3

PORTS
DN1 DN2

1 20

2 20

1" 1" 1 1"

1" 1" 1 1"

f 439 439 439 447

DIMENSIONS mm f1 h 379 379 379 260 387

kg h1 255 n 230 10.0 10.7 10.9

106

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

BETTYNOX 3

BETTYNOX 2

BETTYNOX 1

Head H

(metres)

Flow rate Q

TYPE
Single-phase BETTYNOX 1 BETTYNOX 2 BETTYNOX 3

POWER
kW HP

m3/h l/min

0 0 35 41 47

0.3 5 32 36 42

0.6 10 27 31 38

0.9 15 24 27 34

1.2 20 21 24 31

1.5 25 19 22 28.5

1.8 30 17 20 26

2.1 35 16 19 24

2.4 40 15 17 22

2.7 45 14 16 21.5

3.0 50 13 15 19

0.37 0.50 0.60

0.50 0.70 H metres 0.85

Q = Flow rate H = Total manometric head Hs = Suction height

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

DN2

DN1

h1

f1 f n

TYPE Single-phase BETTYNOX 1 BETTYNOX 2 BETTYNOX 3

PORTS
DN1 DN2

1 20

2 20

1" 1" 1 1"

1" 1" 1 1"

f 439 405 439 413

DIMENSIONS mm f1 h 379 345 379 270 353

kg h1 260 n 198 7.9 8.0 9.2

107

4" submerged pump with peripheral impeller

Stainless steel submersible pump with peripheral impeller and anti-seize system. Standard version includes 10 m power cable and integral capacitor for ease of installation.

RANGE OF PERFORMANCE Flow rate up to 50 l/min (3.0 m3/h) Head up to 68 m LIMITS OF USE Submersion depth up to 40 m Liquid temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


DELIVERY BODY: stainless steel AISI 304. IMPELLER HOUSING WITH PATENTED DOUBLE ANTI-SEIZE INSERTS. IMPELLER: brass, type with radial peripheral vanes. MOTOR JACKET: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MOTOR: asynchronous, dry rewindable stator, for continuous duty 4SKm: single-phase 220240 V - 50 Hz. INSULATION: class F. PROTEZIONE: IP 68. MECHANICAL SEAL: ceramic - graphite - NBR.

STANDARD FEATURES:

4SKm 4SKm Thermal overload protector. INSTALLATION AND USE


It is recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. COMPACT AND ECONOMICAL, IT IS RECOMMENDED FOR DOMESTIC APPLICATIONS INCLUDING WATER SUPPLIES AND IRRIGATION. Internal capacitor Flat type 10 metre power cable.

OPTIONS ON REQUEST

20 metre power cable other voltages or frequency 60 Hz

108

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4SKm100E

Head H (metres)

Flow rate Q

TYPE
Single-phase 4SKm 100E

POWER
kW HP

m3/h l/min

0 0 68

0.3 5 62

0.6 10 55

0.9 15 49

1.2 20 43

1.5 25 37

1.8 30 30

2.1 35 24

2.4 40 17

3.0 50 5

0.75

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Typical installation
DN

Attachment point for safety cable

The 4SK pump may be installed in boreholes with a diameter not less than 4 (100 mm). The electropump is lowered into the borehole by means of the delivery pipe to such a depth as to guarantee its complete immersion (min. 50 cm and at least one metre from the bottom). It is good practice to secure the pump by means of a stainless steel or nylon cable, connected to the anchoring points on the

delivery body.

TYPE Single-phase 4SKm 100E

PORT
DN

DIMENSIONS mm 99.5 h 500

kg 13.1

1"

109

5" submerged pumps with peripheral impeller


with anti-seize inserts

Submerged pumps with peripheral impeller and patented anti-seize system (guarantees pump operation even after long periods of inactivity).

RANGE OF PERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 77 m LIMITS OF USE Submersion depth up to 40 m Liquid temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


DELIVERY BODY: brass with double anti-seize inserts IMPELLER: brass, type with radial peripheral vanes. MOTOR JACKET: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MOTOR: asynchronous, for continuous duty, may be removed and rewound, in an oil bath. 5SKm: single-phase 220240 V - 50 Hz. INSULATION: class F. PROTECTION IP 68. MECHANICAL SEAL: stainless steel - graphite - NBR.

STANDARD FEATURES: 5SKm 5SKm


Check valve. 20 metre neoprene power cable type H07 RN-F with removable connector. Control box with double pole power switch, capacitor and motor overload protector with manual reset.

INSTALLATION AND USE


They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive to the materials from which the pump is made. COMPACT AND ECONOMICAL, THEY ARE RECOMMENDED FOR DOMESTIC APPLICATIONS INCLUDING WATER SUPPLIES AND IRRIGATION.

OPTIONS ON REQUEST

other voltages or frequency 60 Hz

110

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

5SKm100

5SKm150

Head H (metres)

5SKm100M

Flow rate Q

TYPE
Single-phase 5SKm 100 5SKm 100M 5SKm 150

POWER
kW HP

m3/h l/min

0 0 77 42 53

0.3 5 70 40 50

0.6 10 63.5 37.5 47.5

0.9 15 57 35 45

1.2 20 50 32.5 42

1.5 25 43.5 30 39

1.8 30 37 27.5 37

2.1 35 30 25 34

2.4 40 23 22.5 31

3.0 50 10 17.5 26

3.6 60 13 21

4.2 70 8 15

4.8 80 3 10

0.75 0.75 1.1

1 1 1.5

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Typical installation

DN

Attachment point for safety cable

CONTROL BOX

5SK pumps may be installed in boreholes with a diameter not less than 5" (125 mm). The electropump is lowered into the borehole by means of the delivery pipe to such a depth as to guarantee its complete immersion (min. 50 cm and at least one metre from the bottom).

It is good practice to secure the pump by means of a stainless steel or nylon cable, fixed to the holes provided on the delivery body.

TYPE Single-phase 5SKm 100 5SKm 100M 5SKm 150

PORT
DN

11/4"

11/4"
11/4"

120 120 120

h 313 313 313

DIMENSIONS a 200 81 200

mm b 81 200 81

kg c 85 66 85 d 66 85 66 14.9 16.4 16.4

111

multi-stage submersible pumps


for clear water

RANGE OF PERFORMANCE Flow rate up to 100 l/min (6 m3/h) Head up to 42 m LIMITS OF USE Submersion depth up to 10 m Liquid temperature up to + 40C Maximum sand content 50 g/m3 Emptying level up to 30 mm from the bottom CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY AND SUCTION GRID: glass filled technopolymer, particularly resistant to impact and corrosion, with threaded port ISO 228/1. IMPELLERS and DIFFUSERS: technopolymer. DIFFUSER CONTAINER: stainless steel AISI 304. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal ceramic -silicon carbide-NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: asynchronous, for continuous duty. TOP MULTI: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. INSULATION: class F. PROTECTION: IP 68. REGISTERED MODEL n 72765.

STANDARD FEATURES: INSTALLATION AND USE


THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT NO HIGHER THAN 50 g/m3. THEIR HIGH EFFICIENCY AND RELIABILITY MAKES THEM SUITABLE FOR SUPPLYING DOMESTIC WATER FROM TANKS, RESERVOIRS OR RELATIVELY DEEP WELLS, DRAWING RAINWATER FROM CISTERNS, WATERING BY HAND OR FEEDING.

TOP-MULTI Float switch


Neoprene power cable H05 RN-F length 10 metres with Schuko plug. Hosetail. Coupling with non-return valve.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

other voltages or frequency 60 Hz

112

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

TOP-MULTI 3

TOP-MULTI 1

TOP-MULTI 2

Head H (metres)

Flow rate Q

TYPE
Single-phase TOP - MULTI 1 TOP - MULTI 2 TOP - MULTI 3

POWER
kW HP

m3/h l/min

0 0 36 30 42

0.6 10 33 29 38

1.2 20 30.5 28 35

1.8 30 26.5 27 31

2.4 40 21.5 26 25

3.0 50 14.5 24 17,5

3.6 60 5 22 8

4.2 70 19

4.8 80 15

5.4 90 10.5

6.0 100 5

0.37 0.55 0.55

0.50 0.75 H metres 0.75

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical portable application


DN

p minimum

h1 h

minimum

TYPE Single-phase TOP - MULTI 1 TOP - MULTI 2 TOP - MULTI 3

PORT
DN

N stages 6 5 7

a 176 176 176

h 380 380 380 400

DIMENSIONS mm h1 d 345 345 345 365 30 30 30

kg e regolabile regolabile p 350 350 350 350 350 350 8.4 8.1 8.9

11/4"

11/4"
11/4"

113

multi-stage submerged pumps

The best combination of performance, reliability and quiet running, robust and easy to use.

RANGE OF PERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 105 m LIMITS OF USE Liquid temperature up to +40C Maximum sand content 50 g/m3 Submersion depth up to 20 m

CONSTRUCTION CHARACTERISTICS

CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 IMPELLERS AND DIFFUSERS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. SCREWS AND FILTER: stainless steel AISI 304. MOTOR: asynchronous for continuous duty. SUMOm 2: single-phase 220240 V - 50 Hz with thermal overload protector built into windings below 1.5 kW. The 1.8 kW motor has an external overload protector (with manual reset) incorporated into the control box. SUMO 2: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: SUMOm SUMOm 2 (single-phase) control box with capacitor


20 m power cable type H07 RN-F with removable connector and Schuko plug.

INSTALLATION AND USE


THEIR HIGH EFFICIENCY AND RELIABILITY MAKE THEM SUITABLE FOR PUMPING CLEAN WATER IN DOMESTIC, CIVIL AND AGRICULTURAL APPLICATIONS, FOR DISTRIBUTING WATER IN COMBINATION WITH PRESSURE SETS, FOR IRRIGATING GARDENS, BOOSTING PRESSURE, ETC.

SUMO 2

(three-phase) 20 m power cable type H07 RN-F with removable connector.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subkect to our general terms of sale.

economy version 10 m power cable and capacitor, (without control box) single-phase pumps with external float switch (SUMOm 2...- GE) other voltages or frequency 60 Hz

114

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

SUMO2/18

SUMO2/15

Head H (metres)

SUMO2/11

SUMO2/7

SUMO2/6 SUMO2/5

Flow rate Q

TYPE
Single-phase Three-phase SUMOm 2/5 SUMOm 2/6 SUMOm 2/7 SUMO 2/7 SUMOm 2/11 SUMO 2/11 SUMOm 2/15 SUMO 2/15 SUMOm 2/18 SUMO 2/18

POWER
kW HP

m3/h l/min

0 0

0.6 10 35 46 58 72 87 102

1.2 20 33 44 55 70 83 98

1.8 30 31 41 51 66 78 92

2.4 40

2.7 45

3.0 50

3.3 55

3.6 60

3.9 65

4.2 70

4.5 75

4.8 80

0.45 0.55 0.75 1.1 1.5 1.8

0.6 36 0.75 48 1 H metres 60 1.5 75 2 90 105 2.5

Q = Flow rate H = Total manometric head

28 26 25 23 22 20 18 16 14 37.5 35 34 31 29 26 23 19.5 16 47 44 42 38 36 32 28 23 18 61 58 55 52 48 44 40 35 30 73 70 66 62 58 53 48 44 38 85 82 78 73 68 63 57 50 45 Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Single-phase with float switch Single-phase with control box
DN
Connection for safety cable

DN

Connection for safety cable

SUMO with float switch

TYPE Single-phase SUMOm 2/5 - GE SUMOm 2/6 - GE SUMOm 2/7 - GE SUMOm 2/11 - GE SUMOm 2/15 - GE SUMOm 2/18 - GE
TYPE Single-phase Three-phase SUMOm 2/5 SUMOm 2/6 SUMOm 2/7 SUMO 2/7 SUMOm 2/11 SUMO 2/11 SUMOm 2/15 SUMO 2/15 SUMOm 2/18 SUMO 2/18 PORT
DN

11/4" 11/4" 111/4" 1/4" 11/4" 11/4" 11/4"

N stages 3 4 5 5 5 6 7

384 135 482 543 153 648

DIMENSIONS h 384 458 482 543 573 648

mm a 200 200 200 81 200 200 200

kg b 81 81 81 200 81 81 81 c 66 66 66 66 66 66 66 1~ 11.9 14.0 17.3 24.5 25.4 31.2 3~ 15.8 22.8 23.8 27.1

115

SINGLE-PHASE CONTROL BOX

multi-stage submerged pumps

The perfect combination of performance, reliability and quiet running, robust and easy to use.

RANGE OF PERFORMANCE Flow rate up to 120 l/min (7.2 m3/h) Head up to 105 m LIMITS OF USE Liquid temperature up to +40C Maximum sand content 50 g/m3 Submersion depth up to 20 m

CONSTRUCTION CHARACTERISTICS

CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 IMPELLERS AND DIFFUSERS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. SCREWS AND FILTER: stainless steel AISI 304. MOTOR asynchronous for continuous duty. SUMOm 4: single-phase 220240 V - 50 Hz with thermal overload protector built into windings below 1.5 kW. The 1.8 kW motor has an external overload protector (with manual reset) incorporated into the control box. SUMO 4: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTEctION: IP 68.

STANDARD FEATURES: SUMOm SUMOm 4 (single-phase) Control box with capacitor


20 m power cable type H07 RN-F with removable connector and Schuko plug.

INSTALLATION AND USE


THEIR HIGH EFFICIENCY AND RELIABILITY MAKE THEM SUITABLE FOR PUMPING CLEAN WATER IN DOMESTIC, CIVIL AND AGRICULTURAL APPLICATIONS, FOR DISTRIBUTING WATER IN COMBINATION WITH PRESSURE SETS, FOR IRRIGATING GARDENS, BOOSTING PRESSURE, ETC.

SUMO 4

(three-phase) 20 m power cable type H07 RN-F with removable connector.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

economy version 10 m power cable and capacitor, (without control box) single-phase pumps with external float switch (SUMOm 2...- GE) other voltages or frequency 60 Hz

116

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

SUMO4/22

SUMO4/18

Head H (metres)

SUMO4/15

SUMO4/11 SUMO4/7 SUMO4/6 SUMO4/5

Flow rate Q

TYPE
Single-phase SUMOm 4/5 SUMOm 4/6 SUMOm 4/7 SUMOm 4/11 SUMOm 4/15 SUMOm 4/18 SUMOm 4/22 Three-phase SUMO 4/7 SUMO 4/11 SUMO 4/15 SUMO 4/18 SUMO 4/22

POWER
kW HP

m3/h l/min

0 0

1.2 20 27 37 48 56 72 85 101

1.8 30 26 36 46 54 69 83 98

2.4 40 25 34.5 44 52 66 79 94

3.0 50 24 32.5 41 50 64 76 90

3.6 60 22.5 30 38 48 60 73 86

4.2 70 20.5 28 35 46 57 68 80

4.8 80 18 25 32 43 53 64 75

5.4 90 15.5 21.5 28 39 48 58 67

6.0 100 13 18.5 24 36 43 52 60

6.6 110 10 14.5 19 31 38 44 52

7.2 120 7 10 14 24 32 38 44

0.45 0.55 0.75 1.1 1.5 1.8 2.2

0.6 30 0.75 40 1 H metres 50 1.5 60 2 75 2.5 90 3 105

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Single-phase with float switch
DN

Single-phase with control box


DN
Attachment point for safety cable

Attachment point for safety cable

SUMO with float switch

TYPE Single-phase SUMOm 4/5 - GE SUMOm 4/6 - GE SUMOm 4/7 - GE SUMOm 4/11 - GE SUMOm 4/15 - GE SUMOm 4/18 - GE SUMOm 4/22 - GE
TYPE Single-phase Three-phase SUMOm 4/5 SUMOm 4/6 SUMOm 4/7 SUMOm 4/11 SUMOm 4/15 SUMOm 4/18 SUMOm 4/22 SUMO 4/7 SUMO 4/11 SUMO 4/15 SUMO 4/18 SUMO 4/22 PORT
DN

SINGLE-PHASE CONTROL BOX

N stages 3 4 5 4 5 6 7

11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"

384 135 482 513 543 153 573 648

DIMENSIONS h 384 458 482 513 543 573 648

mm a 200 200 200 81 200 200 200

kg b 81 81 81 200 81 81 81 c 66 66 66 66 66 66 66 1~ 11.9 14.0 17.3 23.4 24.5 25.4 31.0 3~ 15.8 21.4 22.8 23.8 27.1

117

vertical multi-stage pumps

Robust vertical multi-stage pumps in stainless steel, distinguished by their high efficiency and particularly quiet operation.

RANGE OF PERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 105 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports ISO 228-1. IMPELLERS AND DIFFUSERS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. SCREWS: stainless steel AISI 304. MOTOR: electric, asynchronous for continuous duty. VLm 2: single-phase 220240 V - 50 Hz with thermal overload protector built into windings below 1.5 kW. The 1.8 kW motor has an external (with manual reset) incorporated into the control box. VL 2: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressiveto to the materials from which the pump is made. THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLE FOR DOMESTIC AND CIVIL APPLICATIONS, BECAUSE THE PUMP IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY THE PUMPED LIQUID, IT CAN BE USED SAFELY IN WET ENVIRONMENTS AND IN SPACES WITH INSUFFICIENT VENTILATION.

STANDARD FEATURES: VLm VLm 2


(single-phase) 2 m power cable type H07 RN-F with removable connector. Control box with capacitor and Schuko plug (three-phase) 2 m power cable type H07 RN-F with removable connector.

VL 2

GUARANTEE 2 YEARS subject to our general terms of sale.

OPTIONS ON REQUEST

other voltages or frequency 60 Hz

118

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

VL2/18

VL2/15

Head H (metres)

VL2/11

VL2/7 VL2/6 VL2/5

Flow rate Q

TYPE
Single-phase VLm 2/5 VLm 2/6 VLm 2/7 VLm 2/11 VLm 2/15 VLm 2/18 Three-phase VL 2/7 VL 2/11 VL 2/15 VL 2/18

POWER
kW HP

m3/h l/min

0 0

0.6 10 35 46 58 72 87 102

1.2 20 33 44 55 70 83 98

1.8 30 31 41 51 66 78 92

2.4 40

2.7 45

3.0 50

3.3 55

3.6 60

3.9 65

4.2 70

4.5 75

4.8 80

0.45 0.55 0.75 1.1 1.5 1.8

0.6 36 0.75 48 1 H metres 60 1.5 75 2 90 2.5 105

Q = Flow rate H = Total manometric head

28 26 25 23 22 20 18 16 14 37.5 35 34 31 29 26 23 19.5 16 47 44 42 38 36 32 28 23 18 61 58 55 52 48 44 40 35 30 73 70 66 62 58 53 48 44 38 85 82 78 73 68 63 57 50 45 Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

a
DN2

SINGLE-PHASE CONTROL BOX

d
DN1

w1 n TYPE Single-phase Three-phase VLm 2/5 VLm 2/6 VLm 2/7 VL 2/7 VLm 2/11 VL 2/11 VLm 2/15 VL 2/15 VLm 2/18 VL 2/18 PORTS
DN1 DN2

s w1

w2 f

w2

11/4"

11/4"

11/4"
11/4" 11/2"

11/4" 11/4 11/4""


11/4" 11/4"

11/2"
11/2"

11/4"

N stages 3 4 5 5 5 6 7

a 90 90 90 100 100 100

b 200 200 200 81 200 200 200

c 81 81 81 200 81 81 81

d 66 66 66 66 66 66 66

DIMENSIONS f h 223 432 223 506 223 530 223 223 603 223 633 223 708

mm h1 50 50 50 60 60 60

h1

h2

kg h2 382 456 480 543 573 648 n 183 183 183 183 183 183 183 w1 62 62 62 62 62 62 62 w2 88.5 88.5 88.5 88.5 88.5 88.5 88.5 s 11 11 11 11 11 11 11 1~ 10.9 13.0 16.3 24.1 25.0 30.8 3~ 14.8 22.4 23.4 26.7

119

vertical multi-stage pumps

Robust vertical multi-stage pumps in stainless steel, distinguished by their high efficiency and particularly quiet operation.

RANGE OF PERFORMANCE Flow rate up to 120 l/min (7.2 m3/h) Head up to 105 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports ISO 228-1. IMPELLERS AND DIFFUSERS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. SCREWS: stainless steel AISI 304. MOTOR: electric, asynchronous for continuous duty. VLm 4: single-phase 220240 V - 50 Hz with thermal overload protector built into windings below 1.5 kW. The 1.8 kW motor has an external overload protector (with manual reset) incorporated into the control box. VL 4: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLE FOR DOMESTIC AND CIVIL APPLICATIONS, BECAUSE THE PUMP IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY THE PUMPED LIQUID, IT CAN BE USED SAFELY IN WET ENVIRONMENTS AND IN SPACES WITH INSUFFICIENT VENTILATION.

STANDARD FEATURES: VLm 4 VLm


(single-phase ) 2 mt power cable type H07 RN-F with removable connector. Control box with capacitor and Schuko plug. (three-phase ) 2 mt power cable type H07 RN-F with removable connector.

VL 4

GUARANTEE 2 YEARS subject to our general terms of sale.

OPTIONS ON REQUEST

other voltages or frequency 60 Hz

120

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

VL4/22

VL4/18

Head H (metres)

VL4/15

VL4/11 VL4/7 VL4/6 VL4/5

Flow rate Q

TYPE
Single-phase VLm 4/5 VLm 4/6 VLm 4/7 VLm 4/11 VLm 4/15 VLm 4/18 VLm 4/22 Three-phase VL 4/7 VL 4/11 VL 4/15 VL 4/18 VL 4/22

POWER
kW HP

m3/h l/min

0 0

1.2 20 27 37 48 56 72 85 101

1.8 30 26 36 46 54 69 83 98

2.4 40 25 34.5 44 52 66 79 94

3.0 50 24 32.5 41 50 64 76 90

3.6 60 22.5 30 38 48 60 73 86

4.2 70 20.5 28 35 46 57 68 80

4.8 80 18 25 32 43 53 64 75

5.4 90 15.5 21.5 28 39 48 58 67

6.0 100 13 18.5 24 36 43 52 60

6.6 110 10 14.5 19 31 38 44 52

7.2 120 7 10 14 24 32 38 44

0.45 0.55 0.75 1.1 1.5 1.8 2.2

0.6 30 0.75 40 1 50 1.5 H metres 60 2 75 2.5 90 105 3

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

a
DN2

SINGLE-PHASE CONTROL BOX

d
DN1

w1 n TYPE Single-phase Three-phase VLm 4/5 VLm 4/6 VLm 4/7 VL 4/7 VLm 4/11 VL 4/11 VLm 4/15 VL 4/15 VLm 4/18 VL 4/18 VLm 4/22 VL 4/22 PORTS
DN1

s w1 DIMENSIONS f h 223 432 223 506 223 530 223 573 223 603 223 633 223 708 mm h1 50 50 50 60 60 60 60 60

w2 f

w2

11/4"

11/4"
11/4" 11/2" 11/2" 11/2" 11/2" 11/2"

N DN2 stages 11/4" 3 111/4" 1/4" 4 11/4" 5 4 11/4"" 1/4 11/4" 5 11/4" " 1/4 1 6 11/4" 7

h1

h2

kg h2 382 456 480 513 543 573 648 n 183 183 183 183 183 183 183 w1 62 62 62 62 62 62 62 w2 88.5 88.5 88.5 88.5 88.5 88.5 88.5 s 11 11 11 11 11 11 11 1~ 10.9 13.0 16.3 23.0 24.1 25.0 30.7 3~ 14.8 21.0 22.4 23.4 26.7

a 90 90 90 100 100 100 100 100

b 200 200 200 81 200 200 200

c 81 81 81 200 81 81 81

d 66 66 66 66 66 66 66

121

in-line multi-stage pumps

Compact multi-stage pumps, in stainless steel, with suction and delivery ports in line. They can be installed in a horizontal or vertical position, or completely submerged. The enclosed design also eliminates any possibility of water escaping.

RANGE OF PERFORMANCE Maximum flow rate 80 l/min (4.8 m3/h) Head up to 105 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports ISO 228-1. IMPELLERS AND DIFFUSORS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. SCREWS: stainless steel AISI 304. MOTOR: electric, asynchronous for continuous duty. VLEm 2: single-phase 220240 V - 50 Hz with thermal overload protector built into windings below 1.5 kW. The 1.8 kW motor has an external overload protector (with manual reset) incorporated into the control box. VLE 2: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLE FOR DOMESTIC AND CIVIL APPLICATIONS AND, BECAUSE THE PUMP IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY THE PUMPED LIQUID, IT CAN BE USED SAFELY IN WET AREAS AND IN SPACES WITH INSUFFICIENT VENTILATION. THE ENCLOSED DESIGN ALSO ELIMINATES THE POSSIBILITY OF WATER ESCAPING AS A RESULT OF SEAL FAILURE, MAKING IT SUITABLE FOR USE IN CARPETED OR OTHER DELICATE ENVIRONMENTS.

STANDARD FEATURES: VLEm VLEm 2


(single-phase) 2 mt power cable type H07 RN-F with removable connector. Control box with capacitor and Schuko plug. (three-phase) 2 mt power cable type H07 RN-F with removable connector.

VLE 2

OPTIONS ON REQUEST

other voltages or frequency 60 Hz

GUARANTEE 2 YEARS subject to our general terms of sale.

122

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

VLE2/18

VLE2/15

Head H (metres)

VLE2/11

VLE2/7

VLE2/6

VLE2/5

Flow rate Q

TYPE
Single-phase VLEm 2/5 VLEm 2/6 VLEm 2/7 VLEm 2/11 VLEm 2/15 VLEm 2/18 Three-phase VLE 2/7 VLE 2/11 VLE 2/15 VLE 2/18

POWER
kW HP

m3/h l/min

0 0

0.6 10 35 46 58 72 87 102

1.2 20 33 44 55 70 83 98

1.8 30 31 41 51 66 78 92

2.4 40

2.7 45

3.0 50

3.3 55

3.6 60

3.9 65

4.2 70

4.5 75

4.8 80

0.45 0.55 0.75 1.1 1.5 1.8

0.6 36 0.75 48 1 H metres 60 1.5 75 2 90 2.5 105

Q = Flow rate H = Total manometric head

28 26 25 23 22 20 18 16 14 37.5 35 34 31 29 26 23 19.5 16 47 44 42 38 36 32 28 23 18 61 58 55 52 48 44 40 35 30 73 70 66 62 58 53 48 44 38 85 82 78 73 68 63 57 50 45 Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Vertical installation
DN2

Horizontal installation

SINGLE-PHASE CONTROL BOX

DN2

DN1

TYPE Single-phase Three-phase VLEm 2/5 VLEm 2/6 VLEm 2/7 VLE 2/7 VLEm 2/11 VLE 2/11 VLEm 2/15 VLE 2/15 VLEm 2/18 VLE 2/18 PORTS
DN

11/4" 11/4"

11/4" 11/4"
11/4" 11/4" 11/4"

N stages 3 4 5 5 5 6 7

397 135 495 547 153 652

DIMENSIONS mm h a 397 471 495 81 547 577 652

kg b c 1~ 8.4 10.5 13.8 20.6 21.5 27.3 3~ 12.3 18.9 19.9 23.2

200

66

DN1

123

in-line multi-stage pumps

Compact multi-stage pumps in stainless steel, with suction and delivery ports in line. They can be installed in a horizontal or vertical position or when completely submerged. The enclosed design also eliminates any possibility of water escaping.

RANGE OF PERFORMANCE Flow rate up to 120 l/min (7.2 m3/h) Head up to 105 m LIMITS OF USE Manometric suction lift up to 7 m Liquid temperature up to + 40C CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

INSTALLATION AND USE


They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made. THEIR RELIABILITY AND QUIET RUNNING MAKE THEM SUITABLE FOR DOMESTIC AND CIVIL APPLICATIONS AND, BECAUSE THE PUMP IS FULLY SUBMERSIBLE WITH THE MOTOR COOLED BY THE PUMPED LIQUID, IT CAN BE USED SAFELY IN WET AREAS AND IN SPACES WITH INSUFFICIENT VENTILATION. THE ENCLOSED DESIGN ALSO ELIMINATES THE POSSIBILITY OF WATER ESCAPING AS A RESULT OF SEAL FAILURE, MAKING IT SUITABLE FOR USE IN CARPETED OR OTHER DELICATE ENVIRONMENTS.

OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports ISO 228-1. IMPELLERS AND DIFFUSERS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide-NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. SCREWS: stainless steel AISI 304. MOTOR: electric, asynchronous for continuous duty. VLm 4: single-phase 220240V - 50 Hz with thermal overload protector built into windings below 1.5 kW. The 1.8 kW motor has an external overload protector (with manual reset) incorporated into the control box. VL 4: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: VLm VLm 4


(single-phase) 2 mt power cable type H07 RN-F with removable connector. Control box with capacitor and Schuko plug. (three-phase) 2 mt power cable type H07 RN-F with removable connector.

VL 4

OPTIONS ON REQUEST

other voltages or frequency 60 Hz

GUARANTEE 2 YEARS subject to our general terms of sale.

124

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

VLE4/22

VLE4/18

Head H (metres)

VLE4/15

VLE4/11 VLE4/7 VLE4/6 VLE4/5

Flow rate Q

TYPE
Single-phase VLEm 4/5 VLEm 4/6 VLEm 4/7 VLEm 4/11 VLEm 4/15 VLEm 4/18 VLEm 4/22 Three-phase VLE 4/7 VLE 4/11 VLE 4/15 VLE 4/18 VLE 4/22

POWER
kW HP

m3/h l/min

0 0

1.2 20 27 37 48 56 72 85 101

1.8 30 26 36 46 54 69 83 98

2.4 40

3.0 50

3.6 60

4.2 70

4.8 80

5.4 90

6.0 100

6.6 110

7.2 120

0.45 0.55 0.75 1.1 1.5 1.8 2.2

0.6 30 0.75 40 1 50 1.5 H metres 60 2 75 2.5 90 105 3

Q = Flow rate H = Total manometric head

25 24 22.5 20.5 18 15.5 13 10 7 34.5 32.5 30 28 25 21.5 18.5 14.5 10 44 41 38 35 32 28 24 19 14 52 50 48 46 43 39 36 31 24 66 64 60 57 53 48 43 38 32 79 76 73 68 64 58 52 44 38 94 90 86 80 75 67 60 52 44 Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Vertical installation
DN2

Horizontal installation

SINGLE-PHASE CONTROL BOX

DN2

DN1

TYPE Single-phase Three-phase VLEm 4/5 VLEm 4/6 VLEm 4/7 VLE 4/7 VLEm 4/11 VLE 4/11 VLEm 4/15 VLE 4/15 VLEm 4/18 VLE 4/18 VLEm 4/22 VLE 4/22 PORTS
DN

11/4" 11/4" 11/4"

11/4"
11/4" 11/4" 11/4"

N stages 3 4 5 4 5 6 7

397 135 495 517 547 153 577 652

DIMENSIONS mm h a 397 471 495 517 81 547 577 652

kg b c 1~ 8.4 10.5 13.8 19.5 20.6 21.5 27.2 3~ 12.3 17.5 18.9 19.9 23.2

200

66

DN1

125

4" monoblock submersible pumps


sand-resistant

4 monoblock submersible pumps designed as a more economic alternative to traditional borehole pumps without loss of performance and reliability. Supplied with integral capacitor and 20 m power cable for ease of installation.

RANGE OF PERFORMANCE Flow rate up to 150 l/min (9 m3/h) Head up to 135 m LIMITS OF USE Liquid temperature up to +30C Maximum sand content 150 g/m3 Submersion depth up to 40 m CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

INSTALLATION AND USE


THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT OF UP TO 150 g/m 3. DUE TO THEIR HIGH EFFICIENCY AND RELIABILITY, THEY ARE RECOMMENDED FOR DOMESTIC WATER SUPPLIES AS PART OF A PRESSURE SET, OR FOR IRRIGATION.

DELIVERY BODY: stainless steel AISI 304 with threaded port ISO 228-1. CASE: stainless steel AISI 304. IMPELLERS AND DIFFUSERS: technopolymer. DIFFUSER HOUSING: stainless steel AISI 304. PUMP SHAFT: stainless steel AISI 304. PUMP BEARINGS: housing in special technopolymer with stainless steel AISI 316 shaft bushes, chrome oxide coated to resist sand. DRIVE COUPLING: stainless steel AISI 316L. SCREWS AND CABLE COVER: stainless steel AISI 304. MOTOR SHAFT: stainless steel AISI 316 (EN 10088-3 - 1.4104 up to 0.75 kW). MOTOR: submersible for continuous duty (dry rewindable). 4BLOCKm: single-phase 220240 V - 50 Hz. 4BLOCK: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68. CHECK VALVE: built into the delivery body. DOUBLE SEAL: mechanical seal ceramic - graphite - NBR with oil barrier chamber and inner lip seal to protect the seal in the event of dry running.

STANDARD FEATURES: 4BLOCKm (single-phase) Motor thermal protection built into the winding.
Internal capacitor. 20 metre flat power cable.

GUARANTEE 2 YEARS subject to our general terms of sale. 4BLOCK

(three-phase) 20 metre flat power cable.

OPTIONS ON REQUEST

30 metre power cable other voltages or frequency 60 Hz

126

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

=54% 4BLOCK2/20
45

4BLOCK2/13

Head H (metres)

4BLOCK2/10

26

Flow rate Q

TYPE
Single-phase 4BLOCKm 2/10 4BLOCKm 2/13 4BLOCKm 2/20 Three-phase 4BLOCK 2/10 4BLOCK 2/13 4BLOCK 2/20

POWER
kW HP

m3/h l/min

0 0 70 90 135

0.6 10 68 88 130

1.2 20 63 82 122

1.8 30 57 74 111

2.4 40 48 62 93

3.0 50 36 46 71

3.6 60 20 26 39

0.55 0.75 1.1

0.75 1 H metres 1.5

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

DN

Typical installation

Attachment point for safety cable

STATIC LEVEL DYNAMIC LEVEL

min 1 metre

TYPE Single-phase Three-phase 4BLOCKm 2/10 4BLOCK 2/10 4BLOCKm 2/13 4BLOCK 2/13 4BLOCKm 2/20 4BLOCK 2/20

PORTS
DN

11/4"

11/4"
11/4"

N stages 10 13 20

DIMENSIONS mm 99.5

kg h 693/668 774/749 987/927 1~ 10.2 11.7 14.9 3~ 9.0 10.6 12.5

127

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4BLOCK4/18

=61%

50

4BLOCK4/14

Head H (metres)

35

4BLOCK4/9 4BLOCK4/7

Flow rate Q

TYPE
Single-phase Three-phase 4BLOCKm 4/7 4BLOCK 4/7 4BLOCKm 4/9 4BLOCK 4/9 4BLOCKm 4/14 4BLOCK 4/14 4BLOCK 4/18

POWER
kW HP

m3/h l/min

0 0 46 60 92 120

1.2 20 44 56 88 112

1.8 30 42 54.5 85 109

2.4 40 40 52 81 104

3.0 50 38 49 76 98

3.6 60 35 45 70 90

4.2 70 31.5 40.5 63 81

4.8 80 27 35 54.5 70

5.4 90 23 29 45 58

6.0 100 17 23 35 45

0.55 0.75 1.1 1.5

0.75 1 H metres 1.5 2

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

DN

Typical installation

Attachment point for safety cable

STATIC LEVEL DYNAMIC LEVEL

min 1 metre

TYPE Single-phase Three-phase 4BLOCKm 4/7 4BLOCK 4/7 4BLOCKm 4/9 4BLOCK 4/9 4BLOCKm 4/14 4BLOCK 4/14 4BLOCK 4/18

PORTS
DN

11/4" 11/4" 11/4" 11/4" 11/4"

N stages 7 9 14 18

DIMENSIONS mm 666/641 735/710 99.5 846/786 /958

kg h 663/638 732/707 901/841 /1014 1~ 9.9 11.3 14.3 3~ 8.7 10.2 11.9 15.0

128

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

=65% 4BLOCK6/13

55

50

4BLOCK6/9

Head H (metres)

4BLOCK6/6

4BLOCK6/4

Flow rate Q

TYPE
Single-phase 4BLOCKm 6/4 4BLOCKm 6/6 4BLOCKm 6/9 Three-phase 4BLOCK 6/4 4BLOCK 6/6 4BLOCK 6/9 4BLOCK 6/13

POWER
kW HP

m3/h l/min

0 0 27 40 61 87

1.5 25 26 38 58 83

3.0 50 24 36 54 78

4.5 75 22 33 50 71

6.0 100 19 29 44 61

7.5 125 15 24 35 49

9.0 150 11 17 26 35

0.55 0.75 1.1 1.5

0.75 1 1.5 H metres 2

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

DN

Typical installation

Attachment point for safety cable

STATIC LEVEL DYNAMIC LEVEL

min 1 metre

TYPE Single-phase Three-phase 4BLOCKm 6/4 4BLOCK 6/4 4BLOCKm 6/6 4BLOCK 6/6 4BLOCKm 6/9 4BLOCK 6/9 4BLOCK 6/13

PORTS
DN

11/4" 111/4" 1/4" 11/4" 11/4"

N stages 4 6 9 13

DIMENSIONS mm 633/608 718/693 99.5 867/807 /1012

kg h 629/604 714/689 864/804 /1008 1~ 9.7 11.3 13.9 3~ 8.5 10.2 11.5 15.4

129

4" submerbible pumps


sand-resistant

The combination of a hydraulic design with floating impellers and the materials used allows the pump to handle sand content of up to 150 g/m3 without risk of blockage or premature wear.

RANGE OF PERFORMANCE Flow rate up to 375 l/min (22.5 m3/h) Head up to 525 m LIMITS OF USE Liquid temperature up to +30C Maximum sand content 150 g/m3 Starts/hour: 20 at regular intervals CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY AND MOTOR BRACKET: stainless steel AISI 304. NON-RETURN VALVE: stainless steel AISI 304. IMPELLERS AND DIFFUSERS: technopolymer. DIFFUSER HOUSING: stainless steel AISI 304. PUMP CASING: stainless steel AISI 304. PUMP SHAFT: stainless steel AISI 304. PUMP BEARINGS: housing in special technopolymer with stainless steel AISI 316 shaft bushes, chrome oxide coated to resist sand. DRIVE COUPLING: stainless steel AISI 316L up to 2.2 kW; stainless steel AISI 304 for higher powers. SCREWS, FILTER AND CABLE COVER: stainless steel AISI 304. MOTOR: Pedrollo 4" submersible electric motor. 4SRm: single-phase220230 V - 50 Hz. 4SR: three-phase380415 V - 50 Hz. PROTECTION: IP 68.

INSTALLATION AND USE


THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT NO HIGHER THAN 150 g/m3. THEIR HIGH EFFICIENCY AND RELIABILITY MAKE THEM SUITABLE FOR USE IN THE DOMESTIC, CIVIL AND INDUSTRIAL SECTORS, INCLUDING FOR WATER SUPPLIES AS PART OF A PRESSURE SET, IRRIGATION, WASHDOWN SYSTEMS, PRESSURE BOOSTING AND FIRE FIGHTING SYSTEMS.

STANDARD FEATURES: 4SRm 4SRm (single-phase) Power cable 1.5 metres long (2.5 metres for motors
over 3 kW). Capacitor supplied loose with Pedrollo motors.

4SR

(three-phase) Power cable 1.5 metres long (2.5 metres for powers higher than 3 kW).

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

pumps for water with a sand content higher than 150 g/m3 pumps for sea water Franklin Electric 4" submersible electric motor other voltages or frequency 60 Hz

130

RANGE OF PERFORMANCE AT n= 2900 1/min

700 600 500 400 300 200

100

50
Head H (metres)

40 30 20

10

1 1 5 10 20 30 50 100 200 300 500

Flow rate Q

DESCRIPTION
Borehole diameter in inches Series Flow rate in m3/h in the point of highest efficiency Single-phase motor Number of stages

4 SR 1 m / 13

131

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

=43% 4SR1/64

35

32

4SR1/45
Head H (metres)

4SR1/35

4SR1/25

4SR1/18

4SR1/13

4SR1/8

Flow rate Q

TYPE
Single-phase 4SR1m/8 4SR1m/13 4SR1m/18 4SR1m/25 4SR1m/35 4SR1m/45 4SR1m/64 Three-phase 4SR1/13 4SR1/18 4SR1/25 4SR1/35 4SR1/45 4SR1/64

POWER
kW HP Q

m3/h l/min

0 0 47 77 107 148 206 266 379

0.3 5 45 73 101 140 197 254 362

0.6 10 42 67 93 129 182 234 332

0.9 15 37 60 83 115 161 207 295

1.2 20 31 51 71 98 136 176 250

1.5 25 24 40 55 77 107 137 195

1.8 30 16 26 36 50 70 90 128

0.25 0.37 0.55 0.75 1.1 1.5 2.2

0.33 0.50 0.75 H metres 1 1.5 2 3

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

132

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4SR1.5/60

=48% =48%

4SR1.5/46

31

28

Head H (metres)

4SR1.5/32

4SR1.5/25

4SR1.5/17

4SR1.5/13

4SR1.5/8 4SR1.5/6

Flow rate Q

TYPE
Single-phase 4SR1.5m/6 4SR1.5m/8 4SR1.5m/13 4SR1.5m/17 4SR1.5m/25 4SR1.5m/32 4SR1.5m/46 Three-phase 4SR1.5/8 4SR1.5/13 4SR1.5/17 4SR1.5/25 4SR1.5/32 4SR1.5/46 4SR1.5/60

POWER
kW HP Q

m3/h l/min

0 0 38 50 81 106 156 200 288 375

0.3 5 36 48 78 102 151 193 277 362

0.6 10 34 46 75 98 144 184 265 346

0.9 15 33 44 71 93 136 175 250 328

1.2 20 30 40 66 86 127 162 233 304

1.5 25 27 36 59 78 115 147 211 276

1.8 30 24 32 52 68 100 128 184 241

2.1 35 20 26 43 56 83 106 153 199

2.4 40 15 20 33 43 64 82 117 153

2.7 45 11 14 23 30 45 58 83 108

0.25 0.37 0.55 0.75 1.1 1.5 2.2 3

0.33 0.50 0.75 1 H metres 1.5 2 3 4

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

133

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4SR2/70

=54%

4SR2/50

45

Head H (metres)

4SR2/39

26

4SR2/27

4SR2/20

4SR2/13 4SR2/10 4SR2/7

Flow rate Q

TYPE
Single-phase 4SR2m/7 4SR2m/10 4SR2m/13 4SR2m/20 4SR2m/27 4SR2m/39 Three-phase 4SR2/7 4SR2/10 4SR2/13 4SR2/20 4SR2/27 4SR2/39 4SR2/50 4SR2/70

POWER
kW HP Q

m3/h l/min

0 0 48 70 90 135 180 260 335 465

0.6 10 46 68 88 130 173 250 322 448

1.2 20 44 63 82 122 164 238 306 427

1.8 30 39 57 74 111 150 216 277 388

2.4 40 33 48 62 93 126 183 235 328

3.0 50 25 36 46 71 96 138 177 248

3.6 60 14 20 26 39 52 75 96 135

0.37 0.55 0.75 1.1 1.5 2.2 3 4

0.50 0.75 1 1.5 H metres 2 3 4 5.5

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

134

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4SR4/78

=61%

4SR4/60

50

Head H (metres)

4SR4/46

35

4SR4/35

4SR4/26

4SR4/18 4SR4/14 4SR4/9 4SR4/7

Flow rate Q

TYPE
Single-phase 4SR4m/7 4SR4m/9 4SR4m/14 4SR4m/18 4SR4m/26 Three-phase 4SR4/7 4SR4/9 4SR4/14 4SR4/18 4SR4/26 4SR4/35 4SR4/46 4SR4/60 4SR4/78

POWER
kW HP Q

m3/h l/min

0 0 46 60 92 120 170 230 308 405 525

1.2 20 44 56 88 112 162 220 293 385 495

1.8 30 42 55 85 109 157 211 280 370 475

2.4 40 40 52 81 104 150 202 269 350 450

3.0 50 38 49 76 98 141 190 249 325 425

3.6 60 35 45 70 90 130 175 230 300 390

4.2 70 32 40 63 81 116 157 205 270 350

4.8 80 28 35 55 70 101 137 181 235 305

5.4 90 23 29 45 58 84 113 151 195 255

6.0 100 17 23 35 45 63 85 117 155 200

0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5

0.75 1 1.5 2 H metres 3 4 5.5 7.5 10

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

135

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4SR6/56

=65%

55

4SR6/42

50

Head H (metres)

4SR6/31

4SR6/23

4SR6/17

4SR6/13 4SR6/9 4SR6/6 4SR6/4

Flow rate Q

TYPE
Single-phase 4SR6m/4 4SR6m/6 4SR6m/9 4SR6m/13 4SR6m/17 Three-phase 4SR6/4 4SR6/6 4SR6/9 4SR6/13 4SR6/17 4SR6/23 4SR6/31 4SR6/42 4SR6/56

POWER
kW HP Q

m3/h l/min

0 0 27 40 61 87 114 154 210 285 380

1.5 25 26 38 58 83 107 148 200 276 365

3.0 50 24 36 54 78 100 138 186 258 340

4.5 75 22 33 50 71 91 128 170 240 315

6.0 100 19 29 44 61 79 112 149 212 280

7.5 125 15 24 35 49 62 92 121 170 233

9.0 150 11 17 26 35 45 67 86 124 173

0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5

0.75 1 1.5 2 3 H metres 4 5.5 7.5 10

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

136

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

=65% 4SR8/42

50

4SR8/31

Head H (metres)

4SR8/23

35

4SR8/17

4SR8/13

4SR8/9 4SR8/7 4SR8/4

Flow rate Q

TYPE
Single-phase 4SR8m/4 4SR8m/7 4SR8m/9 4SR8m/13 Three-phase 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42

POWER
kW HP Q

m3/h l/min

0 0 27 47 60 87 112 153 205 280

2.4 40 26 46 58 85 110 150 200 272

3.6 60 25 45 57 83 108 146 196 266

4.8 80 24 43 55 80 104 141 190 257

6.0 100 23 41 52 76 99 134 181 244

7.2 120 22 38 48 70 92 124 167 225

8.4 140 20 34 43 63 82 111 149 202

9.6 160 17 29 37 54 70 95 128 175

10.8 180 13 23 30 43 56 76 103 140

12.0 200 10 16 21 30 40 53 72 98

0.75 1.1 1.5 2.2 3 4 5.5 7.5

1 1.5 2 3 4 5.5 7.5 10

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

137

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4SR10/35

=63%

4SR10/26
44

40

Head H (metres)

4SR10/20

4SR10/15

4SR10/10

4SR10/7 4SR10/5

Flow rate Q

TYPE
Single-phase 4SR10m/5 4SR10m/7 4SR10m/10 Three-phase 4SR10/5 4SR10/7 4SR10/10 4SR10/15 4SR10/20 4SR10/26 4SR10/35

POWER
kW HP Q

m3/h l/min

0 0 33 46 66 98 130 170 230

3.0 50 31 43 62 92 123 160 216

4.5 75 30 41 59 88 118 154 208

6.0 100 28 39 56 84 112 147 197

7.5 125 26 37 53 79 106 138 184

9.0 150 24 34 48 72 96 126 168

10.5 175 21 30 42 64 85 110 148

12 200 18 25 36 53 71 94 126

13.5 225 14 20 28 42 56 72 100

15.0 250 10 15 20 30 40 52 70

1.1 1.5 2.2 3 4 5.5 7.5

1.5 2 3 4 5.5 7.5 10

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

138

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

=58%

4SR12/29

45

4SR12/22

40

Head H (metres)

4SR12/16

4SR12/12

4SR12/9

4SR12/6 4SR12/4

Flow rate Q

TYPE
Single-phase 4SR12m/4 4SR12m/6 4SR12m/9 Three-phase 4SR12/4 4SR12/6 4SR12/9 4SR12/12 4SR12/16 4SR12/22 4SR12/29

POWER
kW HP Q

m3/h l/min

0 0 25 38 56 75 100 138 182

3.0 50 24 37 55 73 97 135 176

6.0 100

9.0 150

12.0 200

13.2 220

14.4 240

15.6 260

16.8 280

18.0 300

1.1 1.5 2.2 3 4 5.5 7.5

1.5 2 3 4 5.5 7.5 10

H metres

Q = Flow rate H = Total manometric head

22 19 16 15 14 12 11 8 35 32 28 26 24 21 18 14 52 48 42 39 36 32 27 22 69 64 56 52 48 43 36 29 93 86 75 70 64 57 48 38 127 118 103 96 88 78 66 53 167 155 135 126 116 103 88 71 Tolerance of the performance curves according to EN ISO 9906 App. A.

139

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

4SR15/24

=53%

4SR15/18

40

36

Head H (metres)

4SR15/13

4SR15/10

4SR15/7

4SR15/5

Flow rate Q

TYPE
Single-phase 4SR15m/5 4SR15m/7 Three-phase 4SR15/5 4SR15/7 4SR15/10 4SR15/13 4SR15/18 4SR15/24

POWER
kW HP Q

m3/h l/min

0 0 31 44 62 80 112 150

3.0 50 30 42 60 77 108 145

6.0 100 28 40 57 72 102 138

9.0 150 26 37 52 68 95 126

12.0 200 23 32 46 60 85 112

15.0 250 20 27 38 50 71 95

18.0 300 15 20 30 40 55 75

21.0 350 10 13 20 25 37 50

22.5 375 7.5 10 15 19 27 36

1.5 2.2 3 4 5.5 7.5

2 3 4 5.5 7.5 10

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

140

4" submersible pumps with PEDROLLO motors

DN

DIMENSIONS AND WEIGHTS

Attachment for safety cable

h1

TYPE
Three-phase

PORT
DN

DIMENSIONS mm h1 h2
402 519 648 858 1065 1516 310 402 501 648 802 1134 1442 291 347 402 556 685 931 1208 1626 316 360 470 582 758 980 1295 1652 2097 282 342 432 577 696 901 1165 1519 2063 282 372 432 577 696 901 1165 1519 417 519 710 1002 1257 1600 2096 366 470 659 811 1053 1358 1752 422 526 720 875 1173 1522 294 294 319 344 404 454 294 294 319 344 404 454 560 294 294 319 344 404 454 560 660 294 319 344 404 454 560 660 745 850 294 319 344 404 454 560 660 745 850 319 344 404 454 560 660 745 850 344 404 454 560 660 745 850 344 404 454 560 660 745 850 404 454 560 660 745 850

h
696 813 967 1202 1469 1970 604 696 820 992 1206 1588 2002 585 641 721 900 1089 1385 1768 2286 610 679 814 986 1212 1540 1955 2397 2947 576 661 776 981 1150 1461 1825 2264 2913 601 716 836 1031 1256 1561 1910 2369 761 923 1164 1562 1917 2345 2946 710 874 1113 1371 1713 2103 2602 826 980 1280 1535 1918 2372

kg 3~
11.1 12.1 14.7 19.4 23.4 30.7 11.6 13.5 15.4 18.3 21.5 26.7 32.4 11.4 12.9 14.5 17.3 20.4 25.2 25.0 25.0 12.5 14.0 16.3 19.1 23.0 26.8 33.9 41.5 56.8 12.1 13.6 15.7 18.6 21.9 25.3 33.6 38.1 47.0 13.1 15.1 17.4 20.8 23.4 24.5 37.2 44.2 15.4 17.9 21.6 25.6 33.9 38.1 53.0 15.0 17.5 21.2 24.1 33.2 38.4 46.5 17.0 20.8 23.1 30.0 36.5 43.0

TYPE
Single-phase

PORT
DN

DIMENSIONS mm h1 h2
310 402 519 648 858 1065 1516 273 310 402 501 648 802 1134 291 347 402 556 685 931 316 360 470 582 758 282 342 432 577 696 282 372 432 577 417 519 710 366 470 659 422 526 294 294 319 344 404 454 600 294 294 319 344 404 454 600 294 319 344 404 454 600 319 344 404 454 600 319 344 404 454 600 344 404 454 600 404 454 600 404 454 600 454 600

h
604 696 838 992 1262 1519 2116 567 604 721 845 1052 1256 1734 585 666 746 960 1139 1531 635 704 874 1036 1358 601 686 836 1031 1296 626 776 886 1177 821 973 1310 770 924 1259 876 1126

kg 1~
9.3 11.1 13.3 15.8 21.8 25.6 35.4 9.0 12.6 14.5 16.7 20.0 23.7 31.4 12.4 13.2 15.8 19.0 22.6 29.9 13.5 15.3 18.0 21.3 27.7 13.1 14.9 17.4 20.8 26.6 14.4 16.8 19.6 25.5 17.1 20.1 26.3 16.7 19.7 25.9 19.2 25.5

4SR1m/8 - PD 4SR1m/13 - PD 4SR1m/18 - PD 4SR1m/25 - PD 4SR1m/35 - PD 4SR1m/45 - PD 4SR1m/64 - PD 4SR1.5m/6 - PD 4SR1.5m/8 - PD 4SR1.5m/13 - PD 4SR1.5m/17 - PD 4SR1.5m/25 - PD 4SR1.5m/32 - PD 4SR1.5m/46 - PD 4SR2m/7 - PD 4SR2m/10 - PD 4SR2m/13 - PD 4SR2m/20 - PD 4SR2m/27 - PD 4SR2m/39 - PD 4SR4m/7 - PD 4SR4m/9 - PD 4SR4m/14 - PD 4SR4m/18 - PD 4SR4m/26 - PD 4SR6m/4 - PD 4SR6m/6 - PD 4SR6m/9 - PD 4SR6m/13 - PD 4SR6m/17 - PD 4SR8m/4 - PD 4SR8m/7 - PD 4SR8m/9 - PD 4SR8m/13 - PD 4SR10m/5 - PD 4SR10m/7 - PD 4SR10m/10 - PD 4SR12m/4 - PD 4SR12m/6 - PD 4SR12m/9 - PD 4SR15m/5 - PD 4SR15m/7 - PD

11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"

98

4SR1/13 4SR1/18 4SR1/25 4SR1/35 4SR1/45 4SR1/64 4SR1.5/8 4SR1.5/13 4SR1.5/17 4SR1.5/25 4SR1.5/32 4SR1.5/46 4SR1.5/60 4SR2/7 4SR2/10 4SR2/13 4SR2/20 4SR2/27 4SR2/39 4SR2/50 4SR2/70 4SR4/7 4SR4/9 4SR4/14 4SR4/18 4SR4/26 4SR4/35 4SR4/46 4SR4/60 4SR4/78 4SR6/4 4SR6/6 4SR6/9 4SR6/13 4SR6/17 4SR6/23 4SR6/31 4SR6/42 4SR6/56 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42 4SR10/5 4SR10/7 4SR10/10 4SR10/15 4SR10/20 4SR10/26 4SR10/35 4SR12/4 4SR12/6 4SR12/9 4SR12/12 4SR12/16 4SR12/22 4SR12/29 4SR15/5 4SR15/7 4SR15/10 4SR15/13 4SR15/18 4SR15/24

- PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD

11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"

h2

98

141

4" submersible pumps with FRANKLIN ELECTRIC motors

DN

DIMENSIONS AND WEIGHTS

Attachment for safety cable

h1

TYPE
Trefazor

PORT
DN

DIMENSIONS mm h1 h2
402 519 648 858 1065 1516 310 402 501 648 802 1134 1442 291 347 402 556 685 931 1208 1626 316 360 470 582 758 980 1295 1652 2097 282 342 432 577 696 901 1165 1519 2063 282 372 432 577 696 901 1165 1519 417 519 710 1002 1257 1600 2096 366 470 659 811 1053 1358 1752 422 526 720 875 1173 1522 223 242 271 299 327 356 223 242 271 299 327 356 423 223 242 271 299 327 356 423 584 242 271 299 327 356 423 584 698 774 242 271 299 327 356 423 584 698 774 271 299 327 356 423 584 698 774 299 327 356 423 584 698 774 299 327 356 423 584 698 774 327 356 423 584 698 774

h
625 761 919 1157 1392 1872 533 644 772 947 1129 1490 1865 514 589 673 855 1012 1287 1631 2210 558 631 769 909 1114 1403 1879 2350 2871 524 613 731 904 1052 1324 1749 2217 2837 553 671 759 933 1119 1485 1863 2293 716 846 1066 1425 1841 2298 2870 665 797 1015 1234 1637 2056 2526 749 882 1143 1459 1871 2296

kg 3~
11.7 13.6 16.2 21.2 24.0 30.5 11.3 13.0 15.2 18.3 20.9 26.5 32.8 11.1 12.5 14.3 17.2 20.4 23.8 22.8 22.8 12.1 13.8 16.2 18.5 21.6 26.9 36.5 45.8 59.8 11.6 13.4 15.5 18.0 20.5 25.4 33.4 42.5 47.2 12.9 15.0 16.8 19.4 23.5 31.0 38.9 47.2 15.2 17.3 20.2 25.7 33.7 42.5 56.0 14.8 16.9 19.8 24.2 31.8 40.1 48.4 16.4 18.7 23.2 30.2 38.2 46.0

TYPE
Single-phase

PORT
DN

DIMENSIONS mm h1 h2
310 402 519 648 858 1065 1516 273 310 402 501 648 802 1134 291 347 402 556 685 931 316 360 470 582 758 282 342 432 577 696 282 372 432 577 417 519 710 366 470 659 422 526 223 242 271 299 327 356 461 223 242 271 299 327 356 461 242 271 299 327 356 461 271 299 327 356 461 271 299 327 356 461 299 327 356 461 327 356 461 327 356 461 356 461

h
533 644 790 947 1185 1421 1977 496 552 673 800 975 1158 1595 533 618 701 883 1041 1392 587 659 797 938 1219 553 641 759 933 1157 581 699 788 1038 744 875 1171 693 826 1120 778 987

kg 1~
11.2 13.0 15.3 18.1 23.0 25.9 35.6 10.9 12.1 14.2 16.6 19.9 23.3 31.6 11.9 13.6 15.7 19.8 21.5 28.9 13.2 15.2 18.8 20.9 26.7 12.8 14.8 18.2 20.4 25.6 14.3 17.6 19.2 25.6 17.9 19.7 25.3 17.5 19.3 24.9 18.8 23.8

4SR1m/8 - FK 4SR1m/13 - FK 4SR1m/18 - FK 4SR1m/25 - FK 4SR1m/35 - FK 4SR1m/45 - FK 4SR1m/64 - FK 4SR1.5m/6 - FK 4SR1.5m/8 - FK 4SR1.5m/13 - FK 4SR1.5m/17 - FK 4SR1.5m/25 - FK 4SR1.5m/32 - FK 4SR1.5m/46 - FK 4SR2m/7 - FK 4SR2m/10 - FK 4SR2m/13 - FK 4SR2m/20 - FK 4SR2m/27 - FK 4SR2m/39 - FK 4SR4m/7 - FK 4SR4m/9 - FK 4SR4m/14 - FK 4SR4m/18 - FK 4SR4m/26 - FK 4SR6m/4 - FK 4SR6m/6 - FK 4SR6m/9 - FK 4SR6m/13 - FK 4SR6m/17 - FK 4SR8m/4 - FK 4SR8m/7 - FK 4SR8m/9 - FK 4SR8m/13 - FK 4SR10m/5 - FK 4SR10m/7 - FK 4SR10m/10 - FK 4SR12m/4 - FK 4SR12m/6 - FK 4SR12m/9 - FK 4SR15m/5 - FK 4SR15m/7 - FK

11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 1/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"

98

4SR1/13 4SR1/18 4SR1/25 4SR1/35 4SR1/45 4SR1/64 4SR1.5/8 4SR1.5/13 4SR1.5/17 4SR1.5/25 4SR1.5/32 4SR1.5/46 4SR1.5/60 4SR2/7 4SR2/10 4SR2/13 4SR2/20 4SR2/27 4SR2/39 4SR2/50 4SR2/70 4SR4/7 4SR4/9 4SR4/14 4SR4/18 4SR4/26 4SR4/35 4SR4/46 4SR4/60 4SR4/78 4SR6/4 4SR6/6 4SR6/9 4SR6/13 4SR6/17 4SR6/23 4SR6/31 4SR6/42 4SR6/56 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42 4SR10/5 4SR10/7 4SR10/10 4SR10/15 4SR10/20 4SR10/26 4SR10/35 4SR12/4 4SR12/6 4SR12/9 4SR12/12 4SR12/16 4SR12/22 4SR12/29 4SR15/5 4SR15/7 4SR15/10 4SR15/13 4SR15/18 4SR15/24

- FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK

11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"

h2

98

142

EXAMPLES OF INSTALLATION

12 9 5 7 8 4 6 6 4
STATIC LEVEL

10

11

DYNAMIC LEVEL

2 3

min 1 metre

min 1 metre

1) 2) 3) 4) 5) 6)

4SR submersible pump Clamps for securing the power cable Level control probes for dry run protection Anchorage of the pump support cables to the cover of the borehole Pressure gauge Non return valve

7) 8) 9) 10) 11) 12)

Flow rate regulating gate valve Electric power cable Control panel with level probes Pressure vessel Pressure switch Electrovalve/electrocompressor

4SR pumps may be installed in boreholes with a diameter not less than 4 (100 mm). The pump is lowered into the borehole by means of the delivery pipe to such a depth as to guarantee its complete immersion (min. 50 cm and at least one metre from the bottom of the borehole) even during operation, when a lowering of the level of liquid in the borehole may occur. When the pump is installed in a borehole, it is recommended to secure it with a stainless steel or nylon cable, connected to the holes provided on the delivery body.

143

6" submersible pumps


sand-resistant

Innovative mechanical and fluid-dymanic design has produced the new 6SR, manufactured in selected materials for the best combination of reliability, performance and durability. The glass reinforced technopolymer impeller is covered in a specially developed rubber within a sturdy stainless steel housing for maximum resistance to erosion and corrosion.

RANGE OF PERFORMANCE Flow rate up to 1000 l/min (60 m3/h) Head up to 390 m LIMITS OF USE Liquid temperature up to +30C Sand content up to 100 g/m3 Starts/hour: 20 at regular intervals CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT NO HIGHER THAN 100 g/m3. THEIR HIGH EFFICIENCY AND RELIABILITY MAKE THEM SUITABLE FOR USE IN THE DOMESTIC, CIVIL AND INDUSTRIAL SECTORS, INCLUDING FOR WATER SUPPLIES AS PART OF A PRESSURE SET, IRRIGATION, WASHDOWN SYSTEMS, PRESSURE BOOSTING AND FIRE FIGHTING SYSTEMS.

NON-RETURN VALVE: stainless steel AISI 304. IMPELLERS: glass filled technopolymer covered with special rubber DIFFUSER HOUSING: stainless steel AISI 304. DIFFUSERS: technopolymer reinforced with glass fibre . PUMP CASING: stainless steel AISI 304. PUMP SHAFT: stainless steel AISI 304. PUMP BEARINGS: housing in special technopolymer with stainless steel AISI 316 shaft bushes, chrome oxide coated to resist sand. MOTOR BRACKET: nickel-plated cast iron, dimensions to NEMA standards. DRIVE COUPLING: stainless steel AISI 420. SCREWS, FILTER AND CABLE COVER: stainless steel AISI 304. MOTOR: Pedrollo 4" submerged electric motor(up to 3 kW) Pedrollo 6" submerged electric motor(from 4 to 30 kW) 6SR: three-phase380415 V - 50 Hz. PROTECTION: IP 68.

STANDARD FEATURES: 6SR Available in three-phase only.


4 motors have 1.5m power cable 6 motors have 4m power cable

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS

DELIVERY BODY: stainless steel AISI 304 for 6SR36-44, nickel-plated cast iron for 6SR9-12-18-27 with 3" gas threaded port UNI ISO 228-1.

Pedrollo 4" submersible electric motor (up to7.5 kW) Franklin Electric 4" submerged electric motor (up to7.5 kW) Franklin Electric6" submerged electric motor two cable covers to suit dual voltage / (star/ delta) dual voltage motor: 230/400 V or 400/690 V / (star/delta) (from 7.5 kW to 37 kW) other voltages or frequency 60 Hz

144

RANGE OF PERFORMANCE AT n= 2900 1/min

500

100

50

Head H (metres)

10

6SR9

6SR12 6SR18

6SR27 6SR36

6SR44

1 100 200 300 400 500 600 700 800 900

Flow rate Q

DESCRIPTION
Borehole diameter in inches Series Flow rate in m3/h in the point of highest efficiency Number of stages

6 SR 9 / 12

145

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

350
6SR9/24

300

=60% 6SR9/21

250
6SR9/17

40

200
Head H (metres)

35

6SR9/12

150
6SR9/9

100

6SR9/7

6SR9/5

50

Flow rate Q

TYPE
Three-phase 6SR9/5 6SR9/7 6SR9/9 6SR9/12 6SR9/17 6SR9/21 6SR9/24

POWER
kW HP Q

m3/h l/min

0 0 70 98 126 168 238 294 336

3 50

6 100

9 150

12 200

15 250

2.2 3 4 5.5 7.5 9.2 11

3 4 5.5 7.5 H metres 10 12.5 15

Q = Flow rate H = Total manometric head

66 61 53 38 15 92 85 74 53 21 119 110 95 68 27 158 146 127 91 36 224 207 180 129 51 278 256 222 160 63 317 293 255 182 72 Tolerance of the performance curves according to EN ISO 9906 App. A.

146

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

450
=67%

400

6SR12/28

350

6SR12/25
52

300

6SR12/21

47

Head H (metres)

250

6SR12/18

6SR12/15

200

150

6SR12/11

6SR12/8

100
6SR12/6 6SR12/4

50

0 0 50 100 150 200 250 300 350

Flow rate Q

TYPE
Three-phase 6SR12/4 6SR12/6 6SR12/8 6SR12/11 6SR12/15 6SR12/18 6SR12/21 6SR12/25 6SR12/28

POWER
kW HP Q

m3/h l/min

0 0 56 84 111 153 208 250 292 349 390

3.0 50 53 80 106 146 199 239 279 331 371

6.0 100 50 79 100 138 189 225 263 313 350

9.0 150 46 69 91 125 171 205 239 285 319

12.0 200 40 60 80 110 150 180 210 250 280

15.0 250 33 50 66 91 124 149 174 206 231

18.0 300 24 36 47 65 88 106 124 147 165

19.8 330 16 24 32 44 60 72 84 100 112

2.2 3 4 5.5 7.5 9.2 11 13 15

3 4 5.5 7.5 10 H metres 12.5 15 17.5 20

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

147

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

=71%

6SR18/26

58

6SR18/22
50

Head H (metres)

6SR18/18

6SR18/15 6SR18/13 6SR18/11 6SR18/9

6SR18/6 6SR18/4

Flow rate Q

TYPE
Three-phase 6SR18/4 6SR18/6 6SR18/9 6SR18/11 6SR18/13 6SR18/15 6SR18/18 6SR18/22 6SR18/26

POWER
kW HP Q

m3/h l/min

0 0 54 81 122 149 176 203 244 298 352

3 50 53.8 80.5 121 148 175 202 242 296 350

6 100 53 79 119 145.5 172 199 238 291 344

9 150 51 77 116 141 167 193 231 282 334

12 200 49 74 111 135 160 185 221 270 320

15 250 46 69 103 126 149 172 206 252 298

18 300 42 63 94 115 136 157 188 230 272

21 350 37 55 83 101 120 138 165 202 239

24 400 30 45 68 83 98 113 135 165 195

27 450 22 32 48 59 70 80 96 118 139

4 5.5 7.5 9.2 11 13 15 18.5 22

5.5 7.5 10 12.5 H metres 15 17.5 20 25 30

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

148

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

6SR27/27

=68%

56

6SR27/20

6SR27/17
Head H (metres)

41

6SR27/14

6SR27/12

6SR27/10 6SR27/8 6SR27/7

6SR27/5

Flow rate Q

TYPE
Three-phase 6SR27/5 6SR27/7 6SR27/8 6SR27/10 6SR27/12 6SR27/14 6SR27/17 6SR27/20 6SR27/27

POWER
kW HP Q

m3/h l/min

0 0 68 95 109 136 164 191 231 272 367

6 100

12 200

18 300

24 400

30 500

36 600

5.5 7.5 9.2 11 13 15 18.5 22 30

7.5 10 12.5 15 17.5 H metres 20 25 30 40

Q = Flow rate H = Total manometric head

66 62 57 50 37 22 92 87 80 70 52 31 106 99 91 80 59 35 132 124 114 100 74 44 159 149 137 120 89 53 185 174 160 140 104 62 224 211 194 170 126 75 264 248 228 200 148 88 356 335 308 270 205 119 Tolerance of the performance curves according to EN ISO 9906 App. A.

149

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

300
=73% 6SR36/23

275

250

225

6SR36/19
59

200
6SR36/15

175
Head H (metres)

6SR36/13

150
6SR36/11

125

6SR36/10
31

100

6SR36/8

75

6SR36/6

50

6SR36/4

25

0 0 100 200 300 400 500 600 700 800

Flow rate Q

TYPE
Three-phase 6SR36/4 6SR36/6 6SR36/8 6SR36/10 6SR36/11 6SR36/13 6SR36/15 6SR36/19 6SR36/23

POWER
kW HP Q

m3/h l/min

0 0 47 70 94 117 129 152 176 222 269

6 100 45 67 89 111 123 145 167 212 256

12 200 42 63 84 105 115 136 157 199 241

18 300 38 57 76 95 105 124 143 181 219

24 400 34 51 68 85 93 110 127 161 195

30 500 29 44 59 74 81 96 110 140 169

36 600 25 37 50 62 68 81 93 118 143

42 700 19 29 39 48 53 63 72 92 111

48 800 14 20 27 34 37 44 51 65 78

4 5.5 7.5 9.2 11 13 15 18.5 22

5.5 7.5 10 12.5 15 H metres 17.5 20 25 30

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

150

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

275
=73%

250

6SR44/21

225

200
6SR44/16

57

175
Head H (metres)

6SR44/13

150
40

6SR44/11

125
6SR44/9

100

6SR44/8

75

6SR44/6 6SR44/5

50

6SR44/4 6SR44/3

25

Flow rate Q

TYPE
Three-phase 6SR44/3 6SR44/4 6SR44/5 6SR44/6 6SR44/8 6SR44/9 6SR44/11 6SR44/13 6SR44/16 6SR44/21

POWER
kW HP Q

m3/h l/min

0 0 35 47 58 70 93 105 128 151 186 244

12 200 33 44 54 65 87 98 120 141 174 228

18 300 31 42 52 62 83 93 114 135 166 218

24 400 30 40 49 59 79 89 109 128 158 207

30 500 28 37 46 56 74 83 102 120 148 194

36 600 26 34 43 51 68 77 94 111 136 179

42 700 23 31 38 46 61 69 84 99 122 160

48 800 20 27 33 40 53 60 73 86 106 139

54 900 17 23 28 34 45 51 62 73 90 118

60 1000 13 18 22 26 35 39 48 57 70 92

4 5.5 7.5 9.2 11 13 15 18.5 22 30

5.5 7.5 10 12.5 15 H metres 17.5 20 25 30 40

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

151

6" submersible pumps with PEDROLLO motors

versions with 4" motors


TYPE Trhee-phase 6 SR 9/5 LR -PD 6 SR 9/7 LR -PD 6 SR 9/9 LR -PD 6 SR 9/12 LR -PD 6 SR 9/17 LR -PD 6 SR 12/4 LR -PD 6 SR 12/6 LR -PD 6 SR 12/8 LR -PD 6 SR 12/11 LR -PD 6 SR 12/15 LR -PD 6 SR 18/4 LR -PD 6 SR 18/6 LR -PD 6 SR 18/9 LR -PD 6 SR 27/5 LR -PD 6 SR 27/7 LR -PD PORT
DN

-Akg h 1025 1218 1405 1620 1987 982 1175 1362 1577 1901 1188 1360 1596 1364 1575 31.3 34.8 42.4 49.3 56.4 30.3 33.8 41.5 48.3 54.7 37.3 43.2 49.0 43.0 47.6

3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"

137

137

DIMENSIONS mm h1 h2 571 454 658 560 745 660 875 745 1137 850 528 454 615 560 702 660 832 745 1051 850 528 660 615 745 746 850 619 745 725 850

DIMENSIONS AND WEIGHTS

DN

DN

versions with 6" motors


TYPE Trhee-phase 6 SR 9/9 - PD 6 SR 9/12 - PD 6 SR 9/17 - PD 6 SR 9/21 - PD 6 SR 9/24 - PD 6 SR 12/8 - PD 6 SR 12/11 - PD 6 SR 12/15 - PD 6 SR 12/18 - PD 6 SR 12/21 - PD 6 SR 12/25 - PD 6 SR 12/28 - PD 6 SR 18/4 - PD 6 SR 18/6 - PD 6 SR 18/9 - PD 6 SR 18/11 - PD 6 SR 18/13 - PD 6 SR 18/15 - PD 6 SR 18/18 - PD 6 SR 18/22 - PD 6 SR 18/26 - PD 6 SR 27/5 - PD 6 SR 27/7 - PD 6 SR 27/8 - PD 6 SR 27/10 - PD 6 SR 27/12 - PD 6 SR 27/14 - PD 6 SR 27/17 - PD 6 SR 27/20 - PD 6 SR 27/27 - PD 6 SR 36/4 - PD 6 SR 36/6 - PD 6 SR 36/8 - PD 6 SR 36/10 - PD 6 SR 36/11 - PD 6 SR 36/13 - PD 6 SR 36/15 - PD 6 SR 36/19 - PD 6 SR 36/23 - PD 6 SR 44/3 - PD 6 SR 44/4 - PD 6 SR 44/5 - PD 6 SR 44/6 - PD 6 SR 44/8 - PD 6 SR 44/9 - PD 6 SR 44/11 - PD 6 SR 44/13 - PD 6 SR 44/16 - PD 6 SR 44/21 - PD PORT
DN

-Bkg h 1375 1535 1827 2030 2191 1331 1491 1740 1900 2060 2269 2429 1158 1274 1435 1551 1713 1835 1995 2229 2462 1278 1414 1497 1633 1819 1955 2173 2392 2887 1422 1678 1934 2190 2333 2594 2850 3362 387 1309 1452 1595 1738 1994 2142 2398 2684 3083 3773 54.5 59.2 67.4 80.1 86.3 53.6 60.4 65.7 71.4 83.2 89.5 94.6 49.9 53.7 60.0 66.2 71.0 73.4 84.1 92.3 102.6 53.5 58.6 62.6 68.4 72.5 82.1 90.1 99.9 129.4 55.4 62.1 69.2 76.2 81.2 87.2 93.3 105.4 119.4 54.0 57.4 63.1 68.1 75.2 79.2 85.2 98.2 103.3 136.4

3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"

146.5

149.5

DIMENSIONS mm h1 h2 776 599 906 629 1168 659 1341 689 1472 719 732 599 862 629 1081 659 1211 689 1341 719 1515 754 1645 784 559 599 645 629 776 659 862 689 994 719 1081 754 1211 784 1385 844 1558 904 649 629 755 659 808 689 914 719 1065 754 1171 784 1329 844 1488 904 1858 1029 823 599 1049 629 1275 659 1501 689 1614 719 1840 754 2066 784 2518 844 2970 904 710 599 823 629 936 659 1049 689 1275 719 1388 754 1614 784 1840 844 2179 904 2744 1029

h1

h1

h2

-A-

-B-

152

h2

6" submersible pumps with FRANKLIN ELECTRIC motors

versions with 4" motors


TYPE Three-phase 6 SR 9/5 LR - FK 6 SR 9/7 LR - FK 6 SR 9/9 LR - FK 6 SR 9/12 LR - FK 6 SR 9/17 LR - FK 6 SR 12/4 LR - FK 6 SR 12/6 LR - FK 6 SR 12/8 LR - FK 6 SR 12/11 LR - FK 6 SR 12/15 LR - FK 6 SR 18/4 LR - FK 6 SR 18/6 LR - FK 6 SR 18/9 LR - FK 6 SR 27/5 LR - FK 6 SR 27/7 LR - FK PORT
DN

-Akg h 927 1081 132 1573 1911 884 1038 1286 1530 1825 1112 1313 1520 1317 1499 26.6 31.4 38.8 47.0 59.4 25.7 30.5 37.9 46.1 57.7 34.3 41.6 52.0 41.4 50.6

3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"

137

137

DIMENSIONS mm h1 h2 571 356 658 423 745 584 875 698 1137 774 528 356 615 423 702 584 832 698 1051 774 528 584 615 698 746 774 619 698 725 774

DIMENSIONS AND WEIGHTS

DN

DN

versions with 6" motors


TYPE Three-phase 6 SR 9/9 - FK 6 SR 9/12 - FK 6 SR 9/17 - FK 6 SR 9/21 - FK 6 SR 9/24 - FK 6 SR 12/8 - FK 6 SR 12/11 - FK 6 SR 12/15 - FK 6 SR 12/18 - FK 6 SR 12/21 - FK 6 SR 12/25 - FK 6 SR 12/28 - FK 6 SR 18/4 - FK 6 SR 18/6 - FK 6 SR 18/9 - FK 6 SR 18/11 - FK 6 SR 18/13 - FK 6 SR 18/15 - FK 6 SR 18/18 - FK 6 SR 18/22 - FK 6 SR 18/26 - FK 6 SR 27/5 - FK 6 SR 27/7 - FK 6 SR 27/8 - FK 6 SR 27/10 - FK 6 SR 27/12 - FK 6 SR 27/14 - FK 6 SR 27/17 - FK 6 SR 27/20 - FK 6 SR 27/27 - FK 6 SR 36/4 - FK 6 SR 36/6 - FK 6 SR 36/8 - FK 6 SR 36/10 - FK 6 SR 36/11 - FK 6 SR 36/13 - FK 6 SR 36/15 - FK 6 SR 36/19 - FK 6 SR 36/23 - FK 6 SR 44/3 - FK 6 SR 44/4 - FK 6 SR 44/5 - FK 6 SR 44/6 - FK 6 SR 44/8 - FK 6 SR 44/9 - FK 6 SR 44/11 - FK 6 SR 44/13 - FK 6 SR 44/16 - FK 6 SR 44/21 - FK PORT
DN

-Bkg h 1358 1521 1815 2020 2184 1314 1477 1728 1890 2053 2292 2422 1141 1260 1423 1541 1706 1858 1988 2227 2465 1264 1402 1487 1626 1842 1948 2171 2395 2895 1405 1664 1922 2180 2326 2617 2843 3360 3877 1292 1438 1583 1728 1987 2165 2391 2682 3086 3781 56.0 62.3 71.6 83.6 90.2 55.1 63.5 69.9 74.9 87.1 97.2 100.3 51.4 56.8 64.2 69.7 74.9 81.1 89.8 100.6 110.9 56.6 62.8 66.1 72.3 80.2 87.8 98.4 108.2 131.3 56.9 65.2 73.4 79.7 85.1 94.9 99.0 113.7 127.7 55.5 60.5 67.3 71.6 79.1 86.9 90.9 101.5 111.6 138.3

3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"

143.5

146.5

DIMENSIONS mm h1 h2 776 582 906 615 1168 647 1341 679 1472 712 732 582 862 615 1081 647 1211 679 1341 712 1515 777 1645 777 559 582 645 615 776 647 862 679 994 712 1081 777 1211 777 1385 842 1558 907 649 615 755 647 808 679 914 712 1065 777 1171 777 1329 842 1488 907 1858 1037 823 582 1049 615 1275 647 1501 679 1614 712 1840 777 2066 777 2518 842 2970 907 710 582 823 615 936 647 1049 679 1275 712 1388 777 1614 777 1840 842 2179 907 2744 1037

h1

h1

h2

-A-

-B-

h2

153

PEDROLLO MOTORS

4PD
PEDROLLO 4 SUBMERSIBLE ELECTRIC MOTORS
TYPE Rated power
Axial load Revs

- 1~ Starting torque Rated torque Capacitor

Single-phase

P2

Rated current

Starting current

Efficiency

Power factor

h mm

Weight kg

(Vc=450V)

230 V / 50 Hz 4PDm / 0.50 4PDm / 0.75 4PDm / 1 4PDm / 1.5 4PDm / 2 4PDm / 3

0.37 0.55 0.75 1.1 1.5 2.2

0.50 0.75 1 1.5 2 3

1500

2810 2820 2840 2840 2850 2820

3.1 4.2 6.4 8.3 10.8 15.3

8.5 14.5 20.5 27 34 47

64% 66% 68% 70% 71% 69%

0.85 0.86 0.84 0.85 0.85 0.81

0.70 0.75 0.79 0.78 0.76 0.58

16 20 31.5 40 55 75

294 319 344 404 454 600

6.8 8.0 9.1 11.5 13.7 18.4

1500 2500 2500 2500 2500

PEDROLLO 4 SUBMERSIBLE ELECTRIC MOTORS


TYPE Rated power
Axial load Revs

- 3~ Power factor Starting torque Rated torque

Three-phase

P2

Rated current

Starting current

Efficiency

h mm

Weight kg

400 V / 50 Hz 4PD / 0.50 4PD / 0.75 4PD / 1 4PD / 1.5 4PD / 2 4PD / 3 4PD / 4 4PD / 5.5 4PD / 7.5 4PD / 10

kW

HP

1/min

67% 69% 70% 73% 75% 76% 77% 79% 79% 80%

cos

0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5

0.50 0.75 1 1.5 2 3 4 5.5 7.5 10

1500 1500 1500 1500 2500 2500 2500 2500 2500 4500 4500 4500 4500

2815 2815 2820 2835 2830 2840 2830 2840 2830 2840

1.2 1.7 2.1 2.9 4.1 5.6 7.4 9.9 12.9 18.2

4.5 6.4 8 12 16.5 23 35.2 45 62 94.3

0.68 0.69 0.74 0.75 0.75 0.75 0.76 0.75 0.76 0.75

2.20 2.00 2.30 2.60 2.80 3.10 3.20 2.44 2.10 2.73

294 294 319 344 404 454 560 660 745 850

6.8 6.8 8.0 9.1 11.5 13.7 16.1 21.5 25.0 30.0

96

PEDROLLO rewindable submersible motors, oil filled, suitable for food use, 50 Hz (n=2900 1/min) Insulation: class F. - Protection: IP 68. Power cable: 1.5 metres (2.5 metres for powers higher than 3 kW) submersible type, approved for drinking water. LIMITS OF USE: Water temperature: up to +30 C Starts/hour: 25 at regular intervals Cooling: water flow rate not less than 5 cm/s

6PD
PEDROLLO 6 SUBMERSIBLE ELECTRIC MOTORS
TYPE Rated power
Axial load Revs

h
143

38 h 73

kW

HP

1/min

cos

- 3~ Power factor Starting torque Rated torque

Three-phase

P2

Rated current

Starting current

Efficiency

h mm

Weight kg

400 V / 50 Hz 6PD / 5.5 6PD / 7.5 6PD / 10 6PD / 12.5 6PD / 15 6PD / 17.5 6PD / 20 6PD / 25 6PD / 30 6PD / 40 6PD / 50

kW

HP

1/min

79% 80% 81% 82% 82% 83% 83% 84% 85% 85% 86%

cos

4 5.5 7.5 9.2 11 13 15 18.5 22 30 37

5.5 7.5 10 12.5 15 17.5 20 25 30 40 50

10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 20000 20000 20000

2830 2840 2850 2830 2840 2820 2825 2870 2810 2820 2840

9 12.5 16 19.2 22.9 27 31.1 37.8 43.9 62.7 74.4

41.6 64 83 104 127 146 168 227 260 388 418

0.82 0.82 0.84 0.85 0.85 0.84 0.84 0.83 0.85 0.82 0.84

1.8 2 2 2.3 2.2 2.1 2.1 2.4 2.5 2.7 2.4

599 629 659 689 719 754 784 844 904 1029 1189

36.0 38.0 41.0 44.0 47.0 49.0 51.0 55.0 61.0 82.0 98.0

PEDROLLO rewindable submersible motors, oil filled, suitable for food use, 50 Hz (n=2900 1/min) Insulation: class F. - Protection: IP 68. Power cable: 4 metres long, submersible type, approved for drinking water. LIMITS OF USE: Water temperature: up to +30 C Starts/hour: 20 at regular intervals Cooling: water flow rate not less than 16 cm/s

154

FRANKLIN ELECTRIC MOTORS

4FK
FRANKLIN E. 4 SUBMERSIBLE ELECTRIC MOTORS
TYPE Rated power
Axial load Revs

- 1~ Starting torque Rated torque Capacitor

Single-phase

P2

Rated current

Starting current

Efficiency

Power factor

h mm

Weight kg

(Vc=450V)

230 V / 50 Hz 4FKm / 0.50 4FKm / 0.75 4FKm / 1 4FKm / 1.5 4FKm / 2 4FKm / 3

0.37 0.55 0.75 1.1 1.5 2.2

0.50 0.75 1 1.5 2 3

1500 1500 1500 1500 3000 3000 3000 4000

2860 2855 2855 2855 2825 2840

3.4 4.3 5.7 8.6 10.6 15.5

11.2 15.9 21.1 31.8 35 56.7

53% 63% 60% 62% 66% 66%

0.93 0.94 0.98 0.94 0.95 0.97

0.84 0.76 0.89 0.84 0.73 0.65

16 20 31.5 40 55 70

242 271 299 327 356 461

8.7 10.0 11.4 12.7 14.0 18.6

FRANKLIN E. 4 SUBMERSIBLE ELECTRIC MOTORS


TYPE Rated power
Axial load Revs

- 3~ Starting torque Rated torque

Three-phase

P2

Rated current

Starting current

Efficiency

Power factor

h mm

Weight kg

400 V / 50 Hz 4FK / 0.50 4FK / 0.75 4FK / 1 4FK / 1.5 4FK / 2 4FK / 3 4FK / 4 4FK / 5.5 4FK / 7.5 4FK / 10

kW

HP

1/min

66% 67% 69% 73% 73% 75% 76% 78% 76% 74%

cos

0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5

0.50 0.75 1 1.5 2 3 4 5.5 7.5 10

1500 1500 1500 2500 2500 2500 2500 2500 4500 4500 4500

2815 2815 2820 2835 2830 2840 2830 2840 2830 2840

1.1 1.6 2.1 3 4 5.9 7.8 10 13.7 18.4

4.8 6.4 9.3 14.4 19.2 28.9 41.3 58 75.4 101.2

0.70 0.75 0.75 0.76 0.76 0.75 0.75 0.78 0.79 0.79

2.1 1.9 2.1 2.8 2.5 3.1 3.2 3.4 2.8 3.6

223 242 271 299 327 356 423 584 698 774

7.4 8.3 9.5 10.9 12.1 13.5 16.5 24.1 29.4 33.0

95.5

FRANKLIN ELECTRIC resin-impregnated submersible motors, 50 Hz (n=2900 1/min) Insulation: class F. - Protection: IP 68. Power cable: 1.5 metres (2.5 metres for powers higher than 3 kW) submersible type, approved for drinking water. LIMITS OF USE: Water temperature: maximum 30 C Starts/hour: 20 at regular intervals Cooling: water flow rate not less than 8 cm/s

6FK
FRANKLIN E. 6 SUBMERSIBLE ELECTRIC MOTORS
TYPE Rated power
Axial load Revs

- 3~ Starting torque Rated torque

Three-phase

P2

Rated current

Starting current

Efficiency

Power factor

h mm

Weight kg

400 V / 50 Hz 6FK / 5.5 6FK / 7.5 6FK / 10 6FK / 12.5 6FK / 15 6FK / 20 6FK / 25 6FK / 30 6FK / 40 6FK / 50 6FK / 60

kW

HP

1/min

78% 79% 79% 81% 81% 81% 82% 83% 83% 84.5% 86%

cos

4 5.5 7.5 9.2 11 15 18.5 22 30 37 44

5.5 7.5 10 12.5 15 20 25 30 40 50 60

15500 15500 15500 15500 15500 15500 15500 15500 15500 27500 27500 27500 27500

2860 2870 2860 2870 2860 2860 2850 2860 2860 2880 2870

9.3 12.5 16 20.7 23.3 31.3 38.5 45.3 63.5 73 93.9

43 64 83 112 129 169 231 268 393 410 514

0.82 0.82 0.86 0.80 0.85 0.85 0.85 0.86 0.84 0.87 0.84

1.6 1.9 1.9 2.2 2.1 2.1 2.5 2.4 2.6 2.3 2.2

582 615 647 679 712 777 842 907 1037 1405 1558

37.5 41.1 45.2 47.5 50.9 56.7 63.3 69.3 83.9 135.0 148.0

FRANKLIN ELECTRIC resin-impregnated submersible motors, 50 Hz (n=2900 1/min) Insulation: class F. - Protection: IP 68. Power cable: 4 metres long, submersible type, approved for drinking water. LIMITS OF USE: Water temperature: maximum 30 C Starts/hour: 20 at regular intervals Cooling: water flow rate not less than 16 cm/s

137

73

38

kW

HP

1/min

cos

155

DRAINAGE submersible pumps


for clear water

Already recognised for their innovative design and safety features, TOP pumps combine a stainless steel internal motor housing with technologically advanced materials to give an exceptionally robust construction.

RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 14.5 m LIMITS OF USE Depth up to 5 metres (3 metres up to 0.55 kW) Liquid temperature up to + 40C (+90C for a maximum period of 3 minutes) Passage of solid bodies up to 10 mm Drainage level: 14 mm from the bottom for TOP 1-2-3 30 mm from the bottom for TOP 4-5 CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY: glass filled technopolymer, particularly resistant to impact and corrosion, with threaded port ISO 228/1. SUCTION GRID: technopolymer. IMPELLER: open type in technopolymer. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal ceramic -graphite - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous single-phase for continuous duty. TOP: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector built into the winding. INSULATION: class F. PROTECTION: IP 68. REGISTERED MODEL n 72765.

STANDARD FEATURES: TOP 1-2-3 (single-phase) Float switch.


Hosetail. Power cable in neoprene H05 RN-F length 5 metres with Schuko plug.

INSTALLATION AND USE


THE TOP SERIES IS SUITABLE FOR DRAINING CLEAR WATER WITHOUT ABRASIVE PARTICLES. THE CONSTRUCTION GUARANTEES SIMPLE AND SAFE OPERATION DUE TO THE COMPLETE COOLING OF THE MOTOR BY THE PUMPED WATER AND THE DOUBLE SEAL DESIGN. THEY ARE RECOMMENDED FOR EMERGENCY DRAINING OF SMALL FLOODED AREAS (ROOMS, CELLARS, GARAGES), FOR THE DISPOSAL OF WASTE WATER IN THE HOME (DISHWASHER, WASHING MACHINE) AND FOR EMPTYING DRAINAGE TRAPS.

TOP 4-5

(single-phase) Float switch. Hosetail. Couplingwith flap valve. Neoprene power cable H05 RN-F length 10 metres with Schuko plug.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

pumps for aggressive liquids TOP - LA special mechanical seal 10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 versions without float switch other voltages or frequency 60 Hz

156

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

TOP5

TOP4

TOP3

Head H (metres)

TOP2

TOP1

Flow rate Q

TYPE
Single-phase TOP 1 TOP 2 TOP 3 TOP 4 TOP 5

POWER
kW HP

m3/h

1.2 2.4 3.6 4.8 6.0 7.2 8.4 9.6 10.8 12 13.2 14.4 15.6 16.8 18.0 19.2 20.4 21.6 22.8 24 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 2.5 1.5 1 4.5 4 3 2.5 1.8 1 6.5 6 5.5 4.8 4 3.5 2.5 2 8.7 8 7.3 6.7 6 5.3 4.7 4 3.3 2.7 2 10.8 10.2 9.6 8.9 8.3 7.7 7.1 6.4 5.8 5.2 4.5 3.9 3.3 2.6

l/min 0

0.25 0.37 0.55 0.75 0.92

0.33 7 0.50 9 0.75 H metres 10.5 1 12.6 14.5 1.25

6 5.5 4.5 4 3 8 7.5 6.5 6 5.5 10 9 8.8 8 7.5 12 11.5 10.7 10 9.3 14 13.5 12.7 12.1 11.5

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

DN

Typical installation

TOP-LA* for aggressive liquids

TYPE
Single-phase TOP 1 - LA TOP 2 - LA TOP 3 - LA TOP 4 - LA TOP 5 - LA * Wetted metal parts in
AISI 316 stainless steel.

h1 h

p minimum

minimum

a TYPE Single-phase TOP 1 TOP 2 TOP 3 TOP 4 TOP 5 PORT


DN

1" 111/4" 1/4" 111/2" 1/2"


11/4" 11/2"

a 152 152 152 204 204 204

h 232 257 287 334 334 334

h1 217 237 267 310 310 310

DIMENSIONS mm d e 14 14 adjustable 14 21 21 21

kg p 350 350 350 450 450 450 350 350 350 450 450 450 4.1 5.0 6.4 9.8 10.8

157

DRAINAGE submersible pumps


for clear water

The particular constructive design of the TOP FLOOR pump allows draining down to a level of 2 mm above the floor.

RANGE OF PERFORMANCE Flow rate up to 220 l/min (13.2 m3/h) Head up to 9 m LIMITS OF USE Depth up to 3 m Liquid temperature up to +40C (+90 C for a maximum period of 3 minutes) Passage of solid bodies up to 5 mm Drainage level 2 mm from the bottom CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY: glass filled technopolymer, particularly resistant to impact and corrosion, with threaded port ISO 228/1. SUCTION GRID: technopolymer. IMPELLER: open type in technopolymer. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal ceramic - graphite - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous single-phase for continuous duty. TOP-FLOOR: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. INSULATION: class F. PROTECTION: IP 68. REGISTERED MODEL n 72765

STANDARD FEATURES: TOP-FLOOR Neoprene power cable H05 RN-F


length 5 metres with Schuko plug. Hosetail.

INSTALLATION AND USE


THE TOP-FLOOR SERIES IS SUITABLE FOR DRAINING CLEAR WATER WITHOUT ABRASIVE PARTICLES. THEIR ABILITY TO DRAIN WATER DOWN TO 2 MILLIMETRES FROM THE FLOOR MAKES THEM IDEAL FOR EMERGENCY DOMESTIC USE FOR SMALL FLOODED AREAS AND IN ALL THOSE APPLICATIONS WHERE MAXIMUM DRAINAGE IS REQUIRED.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

versions with external float switch special mechanical seal 10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 other voltages or frequency 60 Hz

158

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

TOP2-FLOOR

TOP1-FLOOR

Head H (metres)

Flow rate Q

TYPE
Single-phase TOP1 - FLOOR TOP2 - FLOOR

POWER
kW HP

m3/h l/min

0 0 7 9

1.2 20 6 8

2.4 40 5.5 7.5

3.6 60 4.5 6.5

4.8 80 4 6

6.0 100 3 5.5

7.2 120 2.5 4.5

8.4 140 1.5 4

9.6 160 1 3

10.8 180 2.5

12.0 200 1.8

13.2 220 1

0.25 0.37

0.33 H metres 0.50

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical installation
DN

TYPE Single-phase TOP1 - FLOOR TOP2 - FLOOR

PORT
DN

1" 11/4"

a 152 152 152

DIMENSIONS mm h 232 257

h1 217 237

Minimum drying level

Draining down to 2 mm

h1

kg 3.9 4.9

2 mm
2 mm

2 mm

159

VORTEX submersible pumps


for dirty water

Thanks to the proven VORTEX system, this submersible pump allows the clearing of dirty water containing suspended solid bodies without any risk of clogging the impeller.

RANGE OF PERFORMANCE Flow rate up to 180 l/min (10.8 m3/h) Head up to 7 m LIMITS OF USE Depth up to 3 m Liquid temperature up to + 40C (+90 C for a maximum period of 3 minutes) Passage of solid bodies up to 20 mm Drainage level 25 mm from the bottom CONSTRUCTION AND SAFETY STANDARDS

CONSTRUCTION CHARACTERISTICS

EN 60 335-1 IEC 335-1 CEI 61-150

EN 60034-1 IEC 34-1 CEI 2-3

DELIVERY BODY: glass filled technopolymer, particularly resistant to impact and corrosion, with threaded port ISO 228/1. SUCTION GRID: technopolymer. IMPELLER: technopolymer. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal ceramic - graphite - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous single-phase for continuous duty. TOP-VORTEX: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. INSULATION: class F. PROTECTION: IP 68. REGISTERED MODEL n 72765

STANDARD FEATURES: TOP-VORTEX Float switch.


Hosetail. Neoprene power cable H05 RN-F length 5 metres with Schuko plug.

INSTALLATION AND USE


THE TOP-VORTEX PUMP IS SUITABLE FOR DRAINING DIRTY WATER THAT IS CHEMICALLY NON AGGRESSIVE. THE CONSTRUCTION GUARANTEES SIMPLE AND SAFE OPERATION DUE TO THE COMPLETE COOLING OF THE MOTOR BY THE PUMPED WATER AND THE DOUBLE SEAL DESIGN. IT IS RECOMMENDED FOR DOMESTIC USE, FOR THE CLEARING OF DIRTY WATER, FOR EMPTYING TANKS, DOMESTIC DRAINS AND COLLECTION TRAPS, EVEN WITH SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO 20 mm.

OPTIONS ON REQUEST

special mechanical seal 10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 other voltages or frequency 60 Hz

GUARANTEE 2 YEARS subject to our general terms of sale.

160

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

TOP-VORTEX

Head H (metres)

Flow rate Q

TYPE
Single-phase TOP - VORTEX

POWER
kW HP

m3/h l/min

0 0 7

1.2 20 6.5

2.4 40 6

3.6 60 5.4

4.8 80 4.8

6.0 100 4.2

7.2 120 3.5

8.4 140 3

9.6 160 2.5

10.8 180 1.5

0.37

0.50 H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical installation
DN

h1

p minimum

minimum

TYPE Single-phase TOP - VORTEX

PORT
DN

a 152

h 288

h1 268

DIMENSIONS mm d 25

kg e p 350 350 5.0

11/4"

161

DRAINAGE submersible pumps


for clear water

Robust high-quality submersible pumps in stainless steel, for drainage of clear water. Recommended for fixed installations or for draining domestic water or rainwater, and for emptying tanks or reservoirs.

RANGE OF PERFORMANCE Flow rate up to 300 l/min (18 m3/h) Head up to 23 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 50C
Liquid temperature up to + 60C for intermittent duty. Liquid temperature up to + 90C for intermittent duty maximum 3 minutes.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


Passage of solid bodies up to 10 mm Drainage level: 14 mm from the bottom for RX 1-2 30 mm from the bottom for RX 3-4-5 CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

DELIVERY BODY: stainless steel AISI 304, with threaded port ISO 228/1. SUCTION GRID: stainless steel AISI 304. IMPELLER: stainless steel AISI 304. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal ceramic - graphite - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous single-phase for continuous duty. RXm: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. RX: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68. REGISTERED MODEL.

STANDARD FEATURES: INSTALLATION AND USE


RX PUMPS ARE SUITABLE FOR DRAINING CLEAR WATER WITHOUT ABRASIVE PARTICLES. THE CONSTRUCTION GUARANTEES SIMPLE AND SAFE OPERATION DUE TO THE COMPLETE COOLING OF THE MOTOR BY THE PUMPED WATER, AND THE DOUBLE SEAL DESIGN. THEY ARE RECOMMENDED FOR FIXED INSTALLATIONS, EMERGENCY DRAINING OF SMALL FLOODED AREAS (BASEMENT ROOMS, CELLARS, GARAGES), FOR DISPOSAL OF DIRTY WATER USED IN THE HOME BY WASHING MACHINES AND DISHWASHERS AND FOR DRAINING COLLECTION TRAPS.

RXm RXm (single-phase) float switch.


Neoprene power cable H05 RN-F length 5 metres with Schuko plug.

RX

(three-phase) Neoprene power cable H05 RN-F length 5 metres.

OPTIONS ON REQUEST

special mechanical seal 10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 control box for three-phase electropumps 1.1 kW single-phase versions without float switch other voltages or frequency 60 Hz

162

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

RX5

RX4

RX3

Head H (metres)

RX2

RX1

Flow rate Q

TYPE
Single-phase RXm 1 RXm 2 RXm 3 RXm 4 RXm 5 Three-phase RX 2 RX 3 RX 4 RX 5

POWER
kW HP

m3/h l/min

0 0 7.5 10 17 20 23

1.2 20 6.5 9.5 16 19 22

2.4 40

3.6 60

4.8 80

6.0 100

7.2 120

8.4 140

9.6 160

10.8 12.0 13.2 14.4 15.6 16.8 18.0 180 200 220 240 260 280 300

0.25 0.37 0.55 0.75 1.1

0.33 0.50 0.75 H metres 1 1.5

5.8 5 8.8 8 15 13.8 18 16.8 21 20

4.3 3.5 7.3 6.5 12.8 11.7 15.8 14.7 18.8 17.7

2.8 2 5.8 5 4.3 10.5 9.5 8.5 13.5 12.5 11.5 16.5 15.5 14.5

3.5 2.8 2 7.3 6.3 5.2 4 10.5 9.3 8.2 7.2 13.5 12.4 11.3 10.2

3 6 9

5 8

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical single-phase installation


DN

h1

p minimum

minimum

TYPE Single-phase Three-phase RXm 1 RXm 2 RX 2 RXm 3 RX 3 RXm 4 RX 4 RXm 5 RX 5

PORT
DN

11/4" 11/4" 11/4"

11/4" 11/2" 11/4"


11/4"

a 147 147 147 215 215 215

h 255 255 255 355 355 355

h1 247 247 247 336 336 336

DIMENSIONS mm d e 17 regolabile 17 17 regolabile 30 regolabile adjustable 30 regolabile 30 regolabile

kg p 350 350 350 500 500 500 350 350 350 500 500 500 1~ 4.7 5.7 12.0 13.0 14.0 3~ 5.5 10.7 11.7 12.7

163

VORTEX submersible pump


for dirty water

Robust high-quality VORTEX submersible pumps in stainless steel. The proven VORTEX system allows the clearing of dirty water containing suspended solids.

RANGE OF PERFORMANCE Flow rate up to 450 l/min (27 m3/h) Head up to 14.5 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 50C
Liquid temperature up to + 60C for intermittent duty. Liquid temperature up to + 90C for intermittent duty maximum 3 minutes.

CONSTRUCTION CHARACTERISTICS

Passage of solid bodies: up to 20 mm for RX2 - up to 40 mm for RX3-4-5 Drainage level from the bottom: 25 mm for RX2 - 40 mm forRX3-4-5 CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

DELIVERY BODY: stainless steel AISI 304, with threaded port ISO 228/1. SUCTION GRID: stainless steel AISI 304. IMPELLER: stainless steel AISI 304. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous single-phase for continuous duty. RXm: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. RX: three-phase380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68. REGISTERED MODEL.

STANDARD FEATURES: RXm RXm (single-phase) float switch.


Neoprene power cable H05 RN-F length 5 metres with Schuko plug.

INSTALLATION AND USE


RX-VORTEX PUMPS ARE SUITABLE FOR DRAINING DIRTY WATER. THE CONSTRUCTION GUARANTEES SIMPLE AND SAFE OPERATION, DUE TO THE COMPLETE COOLING OF THE MOTOR BY THE PUMPED WATER. THEY ARE RECOMMENDED FOR DOMESTIC USE, FOR DRAINING DIRTY WATER CONTAINING SUSPENDED SOLIDS.

RX

(three-phase) Neoprene power cable H05 RN-F length 5 metres.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

special mechanical seal 10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 control box for three-phase pumps 1.1 kW single-phase versions without float switch other voltages or frequency 60 Hz

164

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

RX5/40

RX4/40

Head H (metres)

RX3/40

RX2/20

Flow rate Q

TYPE
Single-phase RXm 2/20 RXm 3/40 RXm 4/40 RXm 5/40 Three-phase RX 2/20 RX 3/40 RX 4/40 RX 5/40

POWER
kW HP

m3/h l/min

0 0 7 9 11 15

1.2 20 6.5 8.5 10.5 14.5

2.4 40 6 8 10 14

3.6 60 5.4 7.4 9.4 13.3

4.8 80

7.2

8.4

9.6 10.8 160 180

12

15

18

19.5

21

24

27

100 120 140

200 250

300 325 350

400 450

0.37 0.55 0.75 1.1

0.50 0.75 H metres 1 1.5

Q = Flow rate H = Total manometric head

4.8 4.3 3.7 3.1 2.5 2 6.8 6.3 5.7 5.1 4.5 4 3.4 2 8.8 8.3 7.7 7.1 6.6 6 5.5 4 2.7 2 12.8 12.2 11.6 11 10.4 9.8 9.2 7.8 6.3 5.6 4.9 3.5 2 Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical single-phase installation


DN

h1 h

p minimum

minimum

TYPE Single-phase Three-phase RXm 2/20 RX 2/20 RXm 3/40 RX 3/40 RXm 4/40 RX 4/40 RXm 5/40 RX 5/40

PORT
DN

11/4"
11/2"

11/2"
11/2"

a 147 215 215 215

h 286 405 405 405

h1 278 386 386 386

DIMENSIONS mm d e 25 regolabile 40 regolabile adjustable 40 regolabile 40 regolabile

kg p 350 500 500 500 350 500 500 500 1~ 5.9 12.4 13.4 14.4 3~ 5.7 11.1 12.1 13.1

165

DRAINAGE submersible pumps


for clear water

Submersible pumps for domestic use, economic, compact and reliable. Recommended for draining clear or slightly dirty water.

RANGE OF PERFORMANCE Flow rate up to 300 l/min (18 m3/h) Head up to 14 m LIMITS OF USE Depth up to 5 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 10 mm Drainage level 15 mm from the bottom For continuous duty: minimum immersion 180 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


DELIVERY BODY: cast iron, with threaded port ISO 228/1. MOTOR CASING: stainless steel AISI 304. SUCTION GRID: stainless steel AISI 304. IMPELLER: open type, in technopolymer. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. MOTOR: submersible asynchronous single-phase for continuous duty. ZDm: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: ZDm ZDm Float switch.


Neoprene power cable H07 RN-F length 5 metres with Schuko plug.

INSTALLATION AND USE


DESIGNED FOR DRAINING CLEAR OR SLIGHTLY DIRTY WATER, THEY ARE SUITABLE FOR DOMESTIC USE, FOR DRAINING FLOODED AREAS SUCH AS CELLARS AND FOR EMPTYING TANKS AND RESERVOIRS; THEY ARE OUTSTANDING IN BOTH THEIR SIMPLICITY OF INSTALLATION AND THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.

OPTIONS ON REQUEST

special mechanical seal 10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 versions without float switch other voltages or frequency 60 Hz

166

CURVES AND PERFORMANCE DATA AT n= 2900 1/min


0 0 10 10 20 20 30 30 40 40 50 60 50 70 60 US g.p.m. Imp. g.p.m. feet 45

15 14 13 12 11 10
Head H (metesi)
ZD1A-E ZD1AR-E

40

35

9 8 7 6 5 4 3 2
ZD1B-E

30

25

20

15

10

1 0
0

0
0

25

50

75
5

100

125

150
10

175

200

225

250
15

275

300

l/min
m3/h

Flow rate Q
m3/h l/min 0 0 8.5 11 14 1.5 25 8 10.5 13.5 3.0 50 7.5 10 13 4.5 75 6.5 9 12.2 6.0 100 5.5 8.5 11.5 7.5 125 4.8 7.5 10.5 9.0 150 3.5 6.5 9.5 10.5 175 2.5 5.5 8.3

TYPE
Single-phase ZDm 1B-E ZDm 1A-E ZDm 1AR-E

POWER
kW HP

12.0 200 1 4 7

13.5 225 2.5 5.7

15.0 250 1.5 4.5

16.5 275

18.0 300

0.37 0.50 0.60

0.50 0.70 H metres 0.85

3.2

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical installation
a

h1

DN

p minimum

minimum

TYPE Single-phase ZDm 1B-E ZDm 1A-E ZDm 1AR-E

PORT
DN

11/2"

11/2"
11/2"

a 105 110 105

b 81 81 81

c 136 142 136

DIMENSIONS mm h h1 d 258 66 15 310 258 66 15 273 66 15

kg e regolabile regolabile adjustable regolabile p 450 450 450 450 450 450 9.8 10.4 11.3

167

VORTEX submersible pumps


for very dirty water

VORTEX submersible pumps, economic, compact, reliable, recommended for domestic use. The proven VORTEX system allows the clearing of dirty water containing suspended solid bodies.

RANGE OF PERFORMANCE Flow rate up to 300 l/min (18 m3/h) Head up to 10 m LIMITS OF USE Depth up to 5 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 40 mm Drainage level 40 mm from the bottom For continuous duty: minimum immersion 240 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


DELIVERY BODY: cast iron, with threaded port ISO 228/1. MOTOR CASING: stainless steel AISI 304. IMPELLER: open type, in glass filled technopolymer. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. MOTOR: submersible asynchronous single-phase for continuous duty. ZXm: single-phase 220240 V - 50 Hz with capacitorr and thermal overload protector. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: ZXm ZXm Float switch.


Neoprene power cable H07 RN-F length 5 metres with Schuko plug.

INSTALLATION AND USE


ZX PUMPS ARE RECOMMENDED FOR DRAINING WASTE WATER IN THE DOMESTIC SECTOR, FOR CLEARING DIRTY WATER, EVEN CONTAINING SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO 40 mm. THEY ARE OUTSTANDING IN BOTH THEIR SIMPLICITY OF INSTALLATION AND THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.

OPTIONS ON REQUEST

special mechanical seal 10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 versions without float switch other voltages or frequency 60 Hz

168

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

ZX1A

ZX1B

Head H (metres)

Flow rate Q

TYPE
Single-phase ZXm 1B/40 ZXm 1A/40

POWER
kW HP

m3/h l/min

0 0 9 11

1.5 25 8.5 10.5

3.0 50 8.3 10

4.5 75 8 9.5

6.0 100 7.5 9.2

9.0 150 6.5 8.2

12.0 200 5.2 7

15.0 250 4 5.7

18.0 300 2.5 4.3

21.0 350 1 2.8

24.0 400 1.5

0.50 0.60

0.70 H metres 0.85

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical installation

DN

p minimum

h1

minimum

TYPE Single-phase ZXm 1B/40 ZXm 1A/40

PORT
DN

passage of solid bodies

11/2"

11/2" 11/2"

35 mm 40 mm 35 mm

a 105 110 105

b 86 93 86

c 136 150 136

DIMENSIONS mm h h1 d 372 120 40 372 40 128 325 120 40

kg e regolabile adjustable regolabile p 450 450 450 450 450 450 10.8 12.4

169

DRAINAGE submersible pumps


for clear or slightly dirty water

DRAINAGE submersible pumps for professional use, particularly reliable with generous motor specification and hard-faced mechanical seal.

RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 27 m LIMITS OF USE Depth up to 5 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 10 mm Drainage level 15 mm from the bottom For continuous duty: minimum immersion 220 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY: cast iron, with threaded port ISO 228/1. MOTOR CASING: stainless steel AISI 304. SUCTION GRID: stainless steel AISI 304. IMPELLER: open type, in glass filled technopolymer MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous for continuous duty. Dm: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. D: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: Dm
(single-phase) Float switch. Neoprene power cable H07 RN-F length 5 metres with Schuko plug. (three-phase) Neoprene power cable H07 RN-F length 5 metres.

INSTALLATION AND USE


DESIGNED FOR DRAINING CLEAR OR SLIGHTLY DIRTY WATER WITH SMALL SOLIDS, THEY ARE RECOMMENDED FOR DOMESTIC, CIVIL AND PROFESSIONAL USE, FOR DRAINING FLOODED AREAS SUCH AS CELLARS AND GARAGES OR FOR EMPTYING SWIMMING POOLS OR TANKS AND FOR DISPOSING OF NON-SEWAGE WASTE WATER. THESE PUMPS ARE OUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 control box for three-phase pumps 1.1 kW single-phase pumps without float switch other voltages or frequency 60 Hz

170

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

D30

D20 D15

Head H (metres)

D18 D10

D8

D6

Flow rate Q

TYPE
Single-phase Dm 6 Dm 8 Dm 10 Dm 15 Dm 18 Dm 20 Dm 30 Three-phase D 10 D 15 D 20 D 30

POWER
kW HP

m3/h l/min

0 0

1.5 25

3.0 50

4.5 75

6.0 100

7.5 125

9.0 150

10.5 12.0 175 200

13.5 15.0 16.5 18.0 225 250 275 300

19.5 21.0 24.0 325 350 400

0.45 0.60 0.75 1.1 0.6 0.75 1.1

0.60 0.85 1 H metres 1.5 0.85 1 1.5

9 8.5 8 12 11.5 11 15 14.5 14 19.5 19 18.5 17 16.5 15 21 20 19 27 26 25

7.5 6.8 6 10.5 9.8 9 13.2 12.5 11.8 18 17.5 16.5 13.5 12 10.7 17.5 16 15 23.5 22 21

5.2 4 8.2 7.2 11 10 16 15 9 7.7 13.5 12 19.5 18

2.6 1 6 4.8 9 8 14 13 5 10 16 14.5

3.5 2 6.8 5.4 11.8 10.5

3.5 9.2

2 8

13

11.5

10

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Typical single-phase installation
a

DN

p minimo

h1

b TYPE Single-phase Three-phase Dm 6 Dm 8 Dm 10 D 10 Dm 15 D 15 Dm 18 Dm 20 D 20 Dm 30 D 30 PORT


DN

c DIMENSIONS mm h h1 d 320 66 15 320 66 15 320 66 15 15 340 80 320 66 15 320 66 320 66 15 340 80 15

minimum kg

11/2" 11/2" 11/2" 111/2" 1/2" 11/2" 11/2" 11/2"

a 105 105 105 110 105 105 105 110

b 81 81 81 90 81 81 81 90

c 136 136 136 140 136 136 136 140

e regolabile regolabile regolabile adjustable regolabile regolabile regolabile regolabile

p 500 500 500 500 500 500 500

500 500 500 500 500 500 500 500

1~ 10.6 11.9 13.0 15.2 12.0 13.0 15.2

3~ 11.9 14.1 11.9 14.1

171

VORTEX submersible pumps


for sewage water

VORTEX submersible pumps for professional use, particularly reliable with generous motor specification and hard-faced mechanical seal. The proven VORTEX system allows the clearing of dirty water containing suspended solids.

RANGE OF PERFORMANCE Flow rate up to 500 l/min (30 m3/h) Head up to 15 m LIMITS OF USE Depth up to 5 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 50 mm For continuous duty: minimum immersion 290 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY: cast iron, with threaded port ISO 228/1. MOTOR CASING: stainless steel AISI 304. BASE: stainless steel AISI 304. IMPELLER: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous for continuous duty. VXm: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. VX: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: INSTALLATION AND USE


THEY ARE RECOMMENDED FOR DOMESTIC, CIVIL AND INDUSTRIAL USE, IN APPLICATIONS WHERE THE WATER CONTAINS SUSPENDED SOLIDS WITH DIMENSIONS UP TO 50 mm. THEIR USE IS RECOMMENDED FOR DRYING FLOODED AREAS SUCH AS CELLARS, UNDERGROUND CAR PARKS, CAR WASHING AREAS, OR DOMESTIC DRAINS AND FOR EMPTYING CESSPITS OR SEWAGE DISPOSAL. THESE PUMPS ARE OUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.

VXm VXm (single-phase) Float switch.


Neoprene power cable H07 RN-F length 5 metres with Schuko plug.

VX

(three-phase) Neoprene power cable H07 RN-F length 5 metres.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

10 metre power cable. N.B. required for outdoor use to comply to standard EN 60335-2-41 control panel for three-phase pumps 1.1 kW single-phase pumps without float switch other voltages or frequency 60 Hz

172

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

VX15/35

VX15/50

Head H (metres)

VX10/35

VX8/35 VX10/50 VX8/50

Flow rate Q

TYPE
Single-phase VXm 8/35 VXm 10/35 VXm 15/35 VXm 8/50 VXm 10/50 VXm 15/50 Three-phase VX 10/35 VX 15/35 VX 10/50 VX 15/50

POWER
kW HP

m3/h l/min

0 0 8.4 10 15 6 7.5 11

3 50 7.5 9.5 14 5.5 7 10.5

6 100 6.5 8.5 13 5 6.5 10

9 150 5.2 7.2 11.8 4.4 5.8 9.5

12 200 3.7 5.8 10.5 3.6 5 9

15 250 2 4 9 2.8 4 8.3

18 300 2 7.5 2 3.2 7.5

21 350

24 400

27 450

30 500

0.60 0.75 1.1 0.60 0.75 1.1

0.85 1 1.5 H metres 0.85 1 1.5

6 1 2.4 6.8

4 1.5 6

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Typical single-phase installation
a

DN

p minimum

h1

minimum kg

TYPE Single-phase Three-phase VXm 8/35 VXm 10/35 VX 10/35 VXm 15/35 VX 15/35 VXm 8/50 VXm 10/50 VX 10/50 VXm 15/50 VX 15/50

PORT
DN

passage of solid bodies

11/2" 11/2" 11/2" 11/2" 2" 2" 2" 2"

35 mm 35 mm 35 mm 50 mm 50 mm 50 mm

a 105 105 105 110 110 110 120

b 87 87 87 92 90 90 90 97

c 137 137 137 143 150 150 150 163

DIMENSIONS mm h h1 380 123 380 123 380 123 400 133 410 153 410 153 410 153 430 158

d 40 40 40 55 55 55 55 65

e regolabile regolabile regolabile regolabile adjustable regolabile regolabile regolabile

p 500 500 500 500 500 500 500

500 500 500 500 500 500 500

1~ 12.4 13.5 15.7 13.4 13.9 16.1

3~ 12.1 14.6 12.1 15.0

173

DOUBLE-CHANNEL submersible pumps


for sewage water

DOUBLE-CHANNEL submersible pumps for professional use. Particularly efficient and reliable, with generous motor specification and hard-faced mechanical seal.

RANGE OF PERFORMANCE Flow rate up to 800 l/min (48 m3/h) Head up to 15 m LIMITS OF USE Depth up to 5 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 50 mm For continuous duty: minimum immersion 290 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY: cast iron, with threaded port ISO 228/1. MOTOR CASING: stainless steel AISI 304. BASE: stainless steel AISI 304. IMPELLER: double-channel in stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous for continuous duty. MCm: single-phase 220240 V - 50 Hz with capacitorr and thermal overload protector. MC: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: MCm MCm (single-phase) Float switch.


Neoprene power cable H07 RN-F length 5 metres with Schuko plug.

INSTALLATION AND USE


MC SUBMERSIBLE PUMPS ARE RECOMMENDED FOR DRAINING DIRTY WATER AND SEWAGE IN THE DOMESTIC AND CIVIL SECTORS. THEY ARE EQUIPPED WITH A DOUBLE-CHANNEL STAINLESS STEEL IMPELLER WHICH ALLOWS THE PUMPING OF LIQUIDS CONTAINING SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO 50 mm AND SHORT FIBRES. THEY ARE IDEAL FOR PUMPING DRAINAGE WATER, SEWAGE OR WASTE WATER FOR A SINGLE DWELLING, AND FOR CLEARING SUFACE OR NUISANCE WATER, EVEN IF MUDDY. THESE PUMPS ARE OUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.

MC

(three-phase) Neoprene power cable H07 RN-F length 5 metres.

OPTIONS ON REQUEST

10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 control box for three-phase pumps 1.1 kW single-phase pumps without float switch other voltages or frequency 60 Hz

GUARANTEE 2 YEARS subject to our general terms of sale.

174

CURVES AND PERFORMANCE DATA AT n= 2900 1/min


0 0 20 20 40 40 60 60 80 80 100 120 100 140 120 160 140 180 160 200 220 180 feet 50

16
MC12/50

14

45

12
MC10/50

40

35

10
Head H (metres)
30

25

20

15

4
10

2
5

0 0
0

100
10

200

300
20

400
Flow rate Q
3 50 10.7 14 6 100 9.7 13 9 150 8.7 12.3

500
30

600
40

700

800
50

TYPE
Single-phase MCm 10/50 MCm 12/50 Three-phase MC 10/50 MC 12/50

POWER
kW HP

m3/h l/min

0 0 12 15

12 200 7.8 11.5

15 250 6.8 10.5

18 300 5.9 9.7

21 350 5 8.8

24 400 4 8

27 450 3 7

30 500 2 6.2

36 600 4.5

42 700 2.7

48 800 1

0.75 1.1

1 1.5

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical single-phase installation


a

DN

p minimum

h1

minimum

TYPE Single-phase Three-phase MCm 10/50 MC 10/50 MCm 12/50 MC 12/50

PORT
DN

passage of solid bodies

2" 2" 2"

50 mm 50 mm 50 mm

a 110 120

b 90 97

c 150 163

DIMENSIONS mm h h1 d 410 153 55 430 158 65

kg e regolabile adjustable regolabile p 500 500 500 500 500 500 1~ 14.3 16.5 3~ 13.3 14.3

175

VORTEX submersible pumps


for sewage water

VORTEX stainless steel submersible pumps for professional use, particularly reliable with generous motor specification and hard-faced mechanical seal. The proven VORTEX system allows the clearing of dirty water containing suspended solids.

RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 10 m LIMITS OF USE Depth up to 5 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 50 mm For continuous duty: minimum immersion 280 mm from pump base. CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY: stainless steel AISI 304, with threaded port ISO 228/1. MOTOR CASING AND BASE: stainless steel AISI 304. IMPELLER: stainless steel AISI 304. MOTOR SHAFT: stainless steel AISI 316. DOUBLE SEAL: mechanical seal silicon carbide - NBR - stainless steal AISI 316, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous for continuous duty. VXm-I: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector . VX-I: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: INSTALLATION AND USE


THEY ARE RECOMMENDED FOR DRAINING WASTE WATER IN THE DOMESTIC, CIVIL AND INDUSTRIAL SECTORS, IN APPLICATIONS WHERE THE WATER CONTAINS SUSPENDED SOLIDS WITH DIMENSIONS UP TO 50 mm. THEIR USE IS RECOMMENDED FOR DRYING FLOODED AREAS SUCH AS CELLARS, UNDERGROUND CAR PARKS, CAR WASHING AREAS AND FOR EMPTYING CESSPITS OR SEWAGE DISPOSAL. THESE PUMPS ARE OUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.

VXm-I VXm-I (single-phase) Flow switch.


Neoprene power cable H07 RN-F length 5 metres with Schuko plug.

VX-I

(three-phase) Neoprene power cable H07 RN-F length 5 metres.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 single-phase pumps without float switch other voltages or frequency 60 Hz

176

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

VX10/35-I

VX8/35-I VX10/50-I

Head H (metres)

VX8/50-I

Flow rate Q

TYPE
Single-phase VXm 8/35-I VXm 10/35-I VXm 8/50-I VXm 10/50-I Three-phase VX 10/35-I VX 10/50-I

POWER
kW HP

m3/h l/min

0 0 8.4 10 6 7.5

3 50 7.5 9.5 5.5 7

6 100 6.5 8.5 5 6.5

9 150 5.2 7.2 4.4 5.8

12 200 3.7 5.8 3.6 5

15 250 2 4 2.8 4

18 300 2 2 3.2

21 350

24 400

0.60 0.75 0.60 0.75

0.85 1 H metres 0.85 1

1 2.4

1.5

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical single-phase installation

p minimum

DN

h1

minimum

TYPE Single-phase Three-phase VXm 8/35-I VXm 10/35-I VX 10/35-I VXm 8/50-I VXm 10/50-I VX 10/50-I

PORT
DN

passage of solid bodies

11/2"

11/2" 11/2" 2" 2" 2"

35 mm 35 mm 35 mm 50 mm 50 mm 50 mm

a 108 108 108 118 118 118

b 166 166 166 166 166

DIMENSIONS mm h h1 d 380 87 40 380 87 40 380 87 40 410 108 55 410 108 55 410 108 55

kg e regolabile regolabile adjustable regolabile regolabile p 500 500 500 500 500 500 500 500 500 500 1~ 9.7 9.6 12.8 10.7 3~ 9.3 9.7

177

DOUBLE-CHANNEL submersible pumps


for sewage water

DOUBLE-CHANNEL stainless steel submersible pumps for professional use. Particularly efficient and reliable, with generous motor specification and hard-faced mechanical seal.

RANGE OF PERFORMANCE Flow rate up to 800 l/min (48 m3/h) Head up to 15 m LIMITS OF USE Depth up to 5 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 50 mm For continuous duty: minimum immersion 280 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

DELIVERY BODY: stainless steel AISI 304, with threaded port ISO 228/1. MOTOR CASING AND BASE: stainless steel AISI 304. IMPELLER: double-channel, in stainless steel AISI 304. MOTOR SHAFT: stainless steel AISI 316. DOUBLE SEAL: mechanical seal silicon carbide - NBR - stainless steal AISI 316, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. . MOTOR: submersible asynchronous for continuous duty. MCm-I: single-phase 220240 V - 50 Hz with capacitor and thermal overload protector. MC-I: three-phase 380415V - 50 Hz. INSULATCION: class F. PROTECTION: IP 68.

STANDARD FEATURES: INSTALLATION AND USE


MC-I SUBMERSIBLE PUMPS ARE RECOMMENDED FOR DRAINING DIRTY WATER AND SEWAGE IN THE DOMESTIC AND CIVIL SECTORS. THEY ARE EQUIPPED WITH A DOUBLE-CHANNEL STAINLESS STEEL IMPELLER WHICH ALLOWS THE PUMPING OF LIQUIDS CONTAINING SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO 50 mm AND SHORT FIBRES. THEY ARE IDEAL FOR PUMPING DRAINAGE WATER, SEWAGE OR WASTE WATER FOR A SINGLE DWELLING, AND FOR CLEARING SUFACE OR NUISANCE WATER, EVEN IF MUDDY. THESE PUMPS ARE OUTSTANDING IN THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.

MCm-I MCm-I (single-phase) Float switch.


Neoprene power cable H07 RN-F length 5 metres with Schuko plug.

MC-I

(three-phase) Neoprene power cable H07 RN-F length 5 metres.

OPTIONS ON REQUEST

10 metre power cable. N.B. required for outdoor use to comply with standard EN 60335-2-41 control box for three-phase pumps 1.1 kW single-phase pumps without float switch other voltages or frequency 60 Hz

GUARANTEE 2 YEARS subject to our general terms of sale.

178

CURVES AND PERFORMANCE DATA AT n= 2900 1/min


0 0 20 20 40 40 60 60 80 80 100 120 100 140 120 160 140 180 160 200 220 180 feet 50

16
MC15/50-I

14

45

12
MC10/50-I

40

35

10
Head H (metres)
30

25

20

15

4
10

2
5

0 0
0

100
10

200

300
20

400
Flow rate Q
3 50 10.7 14 6 100 9.7 13 9 150 8.7 12.3

500
30

600
40

700

800
50

TYPE
Single-phase MCm 10/50-I Three-phase MC 10/50-I MC 15/50-I

POWER
kW HP

m3/h l/min

0 0 12 15

12 200 7.8 11.5

15 250 6.8 10.5

18 300 5.9 9.7

21 350 5 8.8

24 400 4 8

27 450 3 7

30 500 2 6.2

36 600 4.5

42 700 2.7

48 800 1

0.75 1.1

1 1.5

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical single-phase installation

p minimum

DN

h1

minimum

TYPE Single-phase Three-phase MCm 10/50-I MC 10/50-I MC 15/50-I

PORT
DN

passage of solid bodies

2" 2" 2"

50 mm 50 mm 50 mm

a 118 118 118

b 166 166 166

DIMENSIONS mm h h1 d 410 109 55 55 109 410 410 109 55

kg e regolabile adjustable regolabile p 500 500 500 500 500 500 1~ 12.8 3~ 9.8 12.8

179

DRAINAGE submersible pumps


for clear or slightly dirty water

DRAINAGE submersible pumps in cast iron, particularly robust and reliable. Ideal for fixed installations.

RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 27 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 10 mm Drainage level to 15 mm from the bottom For continuous duty: minimum immersion 210 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 EN 60 335-1 IEC 34-1 IEC 335-1 CEI 2-3 CEI 61-150 EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS

PUMP BODY: cast iron, with threaded port ISO 228/1. MOTOR CASING: cast iron. SUCTION GRID: stainless steel AISI 304. IMPELLER: cast iron. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous for continuous duty. DCm: single-phase 220240 V - 50 Hz with thermal overload protector. DC: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: DCm DCm


(single-phase) Float switch. Neoprene power cable H07 RN-F length 10 metres with Schuko plug. Electric panel with capacitor. (three-phase) Neoprene power cable H07 RN-F length 10 metres.

IINSTALLATION AND USE


DC SUBMERSIBLE PUMPS, MADE OF EXCEPTIONALLY STURDY HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONGLASTING, ARE RECOMMENDED FOR DRAINING CLEAR OR SLIGHTLY DIRTY WATER AND FOR DISPOSING OF NON-SEWAGE WASTE WATER; THEY ARE OUTSTANDING BOTH IN THEIR STURDINESS AND THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.

DC

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

control box for three-phase pumps 1.1 kW single-phase pumps without float switch other voltages or frequency 60 Hz

180

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

DC30

DC20 DC15

Head H (metres)

DC18 DC10

DC8

DC6

Flow rate Q

TYPE
Single-phase DCm 6 DCm 8 DCm 10 DCm 15 DCm 18 DCm 20 DCm 30 Three-phase DC 10 DC 15 DC 20 DC 30

POWER
kW HP

m3/h l/min

0 0

1.5 25

3.0 50

4.5 75

6.0 100

7.5 125

9.0 150

10.5 12.0 175 200

13.5 15.0 16.5 18.0 225 250 275 300

19.5 21.0 24.0 325 350 400

0.45 0.60 0.75 1.1 0.6 0.75 1.1

0.60 0.85 1 1.5 H metres 0.85 1 1.5

9 8.5 8 12 11.5 11 15 14.5 14 19.5 19 18.5 17 16.5 15 21 20 19 27 26 25

7.5 6.8 6 10.5 9.8 9 13.2 12.5 11.8 18 17.5 16.5 13.5 12 10.7 17.5 16 15 23.5 22 21

5.2 4 8.2 7.2 11 10 16 15 9 7.7 13.5 12 19.5 18

2.6 1 6 4.8 9 8 14 13 5 10 16 14.5

3.5 2 6.8 5.4 11.8 10.5

3.5 9.2

2 8

13

11.5

10

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


a

Typical single-phase installation

SINGLE-PHASE CONTROL BOX

DN

p minimum

o b c

h1

minimum kg

TYPE Single-phase Three-phase DCm 6 DCm 8 DCm 10 DC10 DCm 15 DC15 DCm 18 DCm 20 DC 20 DCm 30 DC 30

PORT
DN

11/2" 11/2" 11/2"

11/2"
11/2" 11/2" 11/2"

a 105 105 105 110 105 105 105 110

b 90 90 90 90 90 90 90

c 136 136 136 140 136 136 136 140

h 285 285 285 310 285 285 285 310

h1 66 66 66 80 66 66 66 80

DIMENSIONS mm m n o 81 200 66 81 200 66 81 200 66 81 200 66 81 200 66 81 200 66 81 200 66

d 15 15 15 15 15 15 15

e p regolabile 500 regolabile 500 regolabile 500 adjustable regolabile 500 regolabile 500 regolabile 500 regolabile 500

500 500 500 500 500 500 500

1~ 14.8 16.1 17.1 19.3 16.1 17.1 19.3

3~ 16.1 18.2 16.1 18.2

181

VORTEX submersible pumps


for sewage water

VORTEX submersible pumps made of cast iron, particularly robust and reliable, ideal for fixed installations. The proven VORTEX system allows the clearing of dirty water containing suspended solids.

RANGE OF PERFORMANCE Flow rate up to 500 l/min (30 m3/h) Head up to 15 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 40C Passage of solid bodies max 35 mm for VXC/35 Passage of solid bodies max 45 mm for VXC/45 For continuous duty: minimum immersion 290 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3

CONSTRUCTION CHARACTERISTICS
l

PUMP BODY: cast iron, with threaded port ISO 228/1. MOTOR CASING AND BASE: cast iron. IMPELLER: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous for continuous duty. VXCm: single-phase 220240 V - 50 Hz with thermal overload protector. VXC: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: VXCm VXCm (single-phase) Float switch.


Neoprene power cable H07 RN-F length 10 metres with Schuko plug. Control box with capacitor (Protection IP 64).

INSTALLATION AND USE


THE PUMPS IN THE VXC SERIES ARE MADE OF EXCEPTIONALLY ROBUST HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND ARE EQUIPPED WITH A VORTEX TYPE IMPELLER. THEY ARE RECOMMENDED FOR DRAINING WASTE WATER CONTAINING SUSPENDED SOLID BODIES, SEWAGE AND WATER MIXED WITH MUD.

VXC

(three-phase) Neoprene power cable H07 RN-F length 10 metres.

OPTIONS ON REQUEST

GUARANTEE 2 YEARS subject to our general terms of sale.

control box for three-phase pumps 1.1 kW single-phase pumps without float switch other voltages or frequency 60 Hz

182

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

VXC15/35

VXC15/45

Head H (metres)

VXC10/35

VXC8/35 VXC10/45 VXC8/45

Flow rate Q

TYPE
Single-phase VXCm 8/35 VXCm 10/35 VXCm 15/35 VXCm 8/45 VXCm 10/45 VXCm 15/45 Three-phase VXC 10/35 VXC 15/35 VXC 10/45 VXC 15/45

POWER
kW HP

m3/h l/min

0 0 8.4 10 15 6 7.5 11

3 50 7.5 9.5 14 5.5 7 10.5

6 100 6.5 8.5 13 5 6.5 10

9 150 5.2 7.2 11.8 4.4 5.8 9.5

12 200 3.7 5.8 10.5 3.6 5 9

15 250 2 4 9 2.8 4 8.3

18 300 2 7.5 2 3.2 7.5

21 350

24 400

27 450

30 500

0.60 0.75 1.1 0.60 0.75 1.1

0.85 1 1.5 H metres 0.85 1 1.5

6 1 2.4 6.8

4 1.5 6

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Typical single-phase installation
a

SINGLE-PHASE CONTROL BOX

DN

p minimum

o b c

h1

minimum

TYPE Single-phase Three-phase VXCm 8/35 VXCm 10/35 VXC 10/35 VXCm 15/35 VXC 15/35 VXCm 8/45 VXCm 10/45 VXC 10/45 VXCm 15/45 VXC 15/45

PORT
DN

passage of solid bodies

11/2"

11/2"
11/2" 2"

2"
2"

35 mm 35 mm 35 mm 45 mm 45 mm 45 mm

a 105 105 105 110 110 110 120

b 87 90 87 92 90 90 90 97

c 137 137 137 143 150 150 150 163

h 350 350 350 370 375 375 375 395

h1 123 123 123 133 148 148 148 153

DIMENSIONS mm m n o 81 200 66 81 200 66 81 200 66 66 81 200 81 200 66 81 200 66 81 200 66

kg d 40 40 40 55 55 55 e regolabile regolabile regolabile adjustable regolabile regolabile regolabile p 500 500 500 500 500 500 500 500 500 500 500 500 500 500 1~ 17.0 18.7 20.9 18.0 19.7 21.9 3~ 17.1 19.8 18.0 20.8

183

DOUBLE-CHANNEL submersible pumps


for sewage water

DOUBLE-CHANNEL cast iron submersible pumps for professional use. Particularly efficient and reliable, with generous motor specification and hard-faced mechanical seal.

RANGE OF PERFORMANCE Flow rate up to 800 l/min (48 m3/h) Head up to 15 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 40C Passage of suspended solid bodies up to 45 mm For continuous duty: minimum immersion 290 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS


PUMP BODY: cast iron, with threaded port ISO 228/1. MOTOR CASING AND BASE: cast iron. IMPELLER: double-channel, in stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE SEAL: mechanical seal silicon carbide - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous for continuous duty. MCm: single-phase 220240 V - 50 Hz with thermal overload protector. MC: three-phase 380415 V - 50 Hz. INSULATION: class F. PROTECTION: IP 68.

STANDARD FEATURES: MCm MCm (single-phase) Float switch.


Neoprene power cable H07 RN-F length 10 metres with Schuko plug. Control box with condenser.

INSTALLATION AND USE


THE PUMPS IN THE MC SERIES ARE MADE OF EXCEPTIONALLY ROBUST HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONG-LASTING. THEY ARE EQUIPPED WITH A DOUBLECHANNEL IMPELLER WHICH ALLOWS THE DRAINAGE OF LIQUIDS CONTAINING SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO 45 mm AND SHORT FIBRES. THEY ARE IDEAL FOR PUMPING DRAINAGE WATER AND SEWAGE, WASTE WATER INCLUDING WATER MIXED WITH MUD, GROUNDWATER AND SURFACE WATER IN APPLICATIONS SUCH AS: CONDOMINIUMS, MULTI-STOREY AND UNDERGROUND CAR PARKS, WASHING AREAS AND INDUSTRY.

MC

(three-phase) Neoprene power cable H07 RN-F length 10 metres.

OPTIONS ON REQUEST

control box for three-phase pumps 1.1 kW single-phase pumps without float switch other voltages or frequency 60 Hz

184

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

MC15/45

MC10/45

Head H (metres)

Flow rate Q

TYPE
Single-phase MCm 10/45 MCm 15/45 Three-phase MC 10/45 MC 15/45

POWER
kW HP

m3/h l/min

0 0 12 15

3 50 10.7 14

6 100 9.7 13

9 150 8.7 12.3

12 200 7.8 11.5

15 250 6.8 10.5

18 300 5.9 9.7

21 350 5 8.8

24 400 4 8

27 450 3 7

30 500 2 6.2

36 600 4.5

42 700 2.7

48 800 1

0.75 1.1

1 1.5

H metres

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical single-phase installation


a

SINGLE-PHASE CONTROL BOX

DN

p minimum

o b c

h1

minimum

TYPE Single-phase Three-phase MCm 10/45 MC 10/45 MCm 15/45 MC 15/45

PORT
DN

passage of solid bodies

2" 2" 2"

45 mm 45 mm 45 mm

a 110 120

b 90 97

c 150 163

h 375 395

h1 148 153

DIMENSIONS mm m n o 81 200 66 81 66 200 81 200 66

kg d 55 55 55 e regolabile adjustable regolabile p 500 500 500 500 500 500 1~ 19.9 22.1 3~ 18.3 21.0

185

VORTEX submersible pumps


for sewage water

VORTEX submersible pumps in cast iron, particularly robust and reliable, intended for continuous heavy duty use in fixed installations, in building services and industry. Recommended for sewage and waste water of all types with solid impurities.

RANGE OF PERFORMANCE Flow rate up to 1200 l/min (72 m3/h) Head up to 16 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 40C Passage of solid bodies max 50 mm for VXC 15-20-30/50 Passage of solid bodies max 70 mm for VXC 15-20-30/70 For continuous duty: minimum immersion 420 mm from pump base CONSTRUCTION AND SAFETY STANDARDS

CONSTRUCTION CHARACTERISTICS

PUMP BODY, MOTOR CASING: cast iron. IMPELLER: cast iron. BASE: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057. DOUBLE SEAL: mechanical seal silicon carbide - widia -NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous, 2 pole, for continuous duty. VXCm: single-phase 220240 V - 50 Hz Models up to 1.5 kW have built in thermal protection
- 2.2 kW single-phase versions have a thermal protector provided in the winding for connection to the control box.

VXC:

three-phase 380415 V - 50 Hz.


- Thermal protectors are provided in the winding for connection to the external control panel

EN 60034-1 IEC 34-1 CEI 2-3

INSULATION: class F.

PROTECTION: IP 68.

STANDARD FEATURES: INSTALLATION AND USE


VXC SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUST HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONGLASTING, AND HAVE A VORTEX TYPE IMPELLER. THEY ARE SUITABLE FOR SEWAGE, WASTE WATER AND SLUDGE, INCLUDING WATER CONTAINING SOLIDS OR MUD. THEY ARE IDEAL FOR SEWAGE INSTALLATION, TUNNELS AND OTHER EXCAVATIONS, UNDERGROUND CAR PARKS AND SIMILAR APPLICATIONS.

VXCm (single-phase) Float switch. VXCm


10m H07 RN-F submersible power cable with Schuko plug. 1.1 to 1.5 kW models are supplied with control box with capacitor and manual reset motor protector. 2.2 kW models are supplied with control box type QES 300 MONO.

VXC GUARANTEE 2 YEARS subject to our general terms of sale.

(three-phase) 10m H07 RN-F neoprene power cable

OPTIONS ON REQUEST

control box for three-phase pumps dual voltage: 230/400 V or 400/690 V single-phase versions without float switch other voltages or frequency 60 Hz

186

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

VXC30/50

VXC20/50

VXC15/50 VXC30/70

Head H (metres)

VXC20/70

VXC15/70

Flow rate Q

TYPE
Single-phase VXCm 15/50 VXCm 20/50 VXCm 30/50 VXCm 15/70 VXCm 20/70 VXCm 30/70 Three-phase VXC 15/50 VXC 20/50 VXC 30/50 VXC 15/70 VXC 20/70 VXC 30/70

POWER
kW HP

m3/h l/min

0 0

6 100 10.5 12 15

12 200 9.5 11 14 5.5 7.4 9.7

18 300 8.2 9.5 13 5 6.7 9

21 350 7.2 9 12.3 4.7 6.3 8.6

24 400 6.5 8 11.5 4.4 6 8.2

30 500 4.5 6.5 10 3.7 5.2 7.5

36 600 2 4.5 8 3 4.5 6.7

42 700 2 5.9 2.2 3.6 5.8

48 800

51 850

54 900

60 1000

66

72

1100 1200

1.1 1.5 2.2 1.1 1.5 2.2

1.5 2 3 1.5 2 3

11.5 13 H metres 16 6.5 8.5 11

3.3 1.5 2.8 5

2 1 2.4 4.6

2 4.2

1 3.3

2.5

1.5

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Typical single-phase installation
a

SINGLE-PHASE CONTROL BOX

DN

p minimum

o b c DIMENSIONS mm m n o

h1

minimum kg

TYPE Single-phase Three-phase VXCm 15/50 VXC 15/50 VXCm 20/50 VXC 20/50 VXCm 30/50 VXC 30/50 VXCm 15/70 VXC 15/70 VXCm 20/70 VXC 20/70 VXCm 30/70 VXC 30/70

PORT
DN

passage of solid bodies

21/2"

21/2"
21/2" 3"

3"
3"

50 mm 50 mm 50 mm 70 mm 70 mm 70 mm

a 162 162 162 180 180 180

b 135 135 135 150 150 150

c h h1 212 490 188 490 212 490 188 212 500/490 188 240 530 530 230 240 530 230 240 540/530 230

81

200

85

d 75 75 75 85 85 85

e p regolabile 800 regolabile 800 regolabile 800 adjustable 800 regolabile 800 regolabile 800 regolabile 800

800 75 800 800 800 85 800

1~ 33.3 34.8 40.7 38.9 40.8 47.0

3~ 31.0 33.3 34.8 36.6 38.9 41.1

187

SINGLE-CHANNEL submersible pumps


for sewage water

SINGLE-CHANNEL submersible pumps highly efficient and particularly robust and reliable. Ideal for fixed installations or for continuous heavy duty use, recommended for sewage and waste water with solid impurities in building services or industrial applications.

RANGE OF PERFORMANCE Flow rate up to 1600 l/min (96 m3/h) Head up to 24 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 40C Passage of solid bodies max 50 mm for MC 15-20-30/50 Passage of solid bodies max 70 mm for MC 30/70 For continuous duty: minimum immersion 420 mm from pump base CONSTRUCTION AND SAFETY STANDARDS

CONSTRUCTION CHARACTERISTICS

PUMP BODY, MOTOR CASING: cast iron. IMPELLER: single-channel, in cast iron. BASE: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057. DOUBLE SEAL: mechanical seal silicon carbide - widia - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous, 2 pole, for continuous duty. MCm: single-phase 220240 V - 50 Hz Models up to 1.5 kW have built in thermal protection
- 2.2 kW single-phase versions have a thermal protector provided in the winding for connection to the control box.

MC:

three-phase 380415 V - 50 Hz.


- Thermal protectors are provided in the winding for connection to the external control panel

EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE


MC SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUST HEAVY GAUGE CAST IRON, ABRASION RESISTANT AND LONG-LASTING, WITH A SINGLE-CHANNEL IMPELLER WHICH CAN HANDLE LIQUIDS WITH SUSPENDED SOLIDS AND SHORT FIBRES. THEY ARE IDEAL FOR SEWAGE, WASTE AND GROUND WATER, EVEN WITH SOLIDS OR MUD, AND ARE THEREFORE RECOMMENDED FOR BUILDING OR INDUSTRIAL EFFLUENT AND DRAINAGE OF LARGE AREAS SUCH AS CAR PARKS.

INSULATION: class F.

PROTECTION: IP 68.

STANDARD FEATURES: MCm MCm (single-phase) Float switch.


10m H07 RN-F submersible power cable with Schuko plug. 1.1 to 1.5 kW models are supplied with control box with capacitor and manual reset motor protector. 2.2 kW models are supplied with control box type QES 300 MONO.

MC

(three-phase) 10m H07 RN-F neoprene power cable

GUARANTEE 2 YEARS subject to our general terms of sale. OPTIONS ON REQUEST

control box for three-phase pumps dual voltage: 230/400 V or 400/690 V single-phase versions without float switch other voltages or frequency 60 Hz

188

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

MC30/50

MC20/50

Head H (metres)

MC15/50

MC30/70

Flow rate Q

TYPE
Single-phase MCm 15/50 MCm 20/50 MCm 30/50 MCm 30/70 Three-phase MC 15/50 MC 20/50 MC 30/50 MC 30/70

POWER
kW HP

m3/h l/min

0 0

3 50

6 100

12

18

24 400

30 500 7 9 14 9.5

36 600 5 7 12 8.8

42 700 3 5 10 8.2

48 800 1 3 8 7.6

54

60

66

72

84

96

200 300

900 1000 1100 1200 1400 1600 1 6 6.8

1.1 1.5 2.2 2.2

1.5 2 3 3

16 18 H metres 24 13

14 16 22

12.5 10.5 8.5 14 12.5 10.5 20 18 16 11.5 11 10.2

4 6

2 5.3

4.8

3.2

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS

Typical single-phase installation


a

SINGLE-PHASE CONTROL BOX

DN

p minimum

o b c

h1

minimum

TYPE Single-phase Three-phase MCm 15/50 MC 15/50 MCm 20/50 MC 20/50 MCm 30/50 MC 30/50 MCm 30/70 MC 30/70

PORT
DN

passage of solid bodies

21/2"

21/2"
21/2"

3"

50 mm 50 mm 50 mm 70 mm

a 162 162 162 180

b 135 135 135 150

c h h1 212 490 188 490 212 490 188 212 500/490 188 240 540/530 230

DIMENSIONS mm m n o 81 200 85

kg d 75 75 75 85 e regolabile regolabile regolabile regolabile regolabile p 800 800 800 800 800 800 800 800 800 800 1~ 34.0 35.7 41.7 48.0 3~ 31.8 34.0 35.8 42.1

189

VORTEX submersible pumps


for sewage water

stationary version
PVXC series pumps are supplied complete with base pedestal elbow (with mating flange), pump slide bracket and guide tube top support, for fixed sewer installations.

RANGE OF PERFORMANCE Flow rate up to 1200 l/min (72 m3/h) Head up to 16 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 40C Passage of solid bodies max 50 mm for PVXC 15-20-30/50 Passage of solid bodies max 70 mm for PVXC 15-20-30/70 For continuous duty: minimum immersion 430 mm from pump base CONSTRUCTION AND SAFETY STANDARDS

CONSTRUCTION CHARACTERISTICS

PUMP BODY, MOTOR CASING AND BASE PEDESTAL: cast iron. IMPELLER: cast iron. BASE: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057. DOUBLE SEAL: mechanical seal silicon carbide - widia - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous, 2 pole, for continuous duty. PVXCm: single-phase 220240 V - 50 Hz Models up to 1.5 kW have built in thermal protection
- 2.2 kW single-phase versions have a thermal protector provided in the winding for connection to the control box.

PVXC:

three-phase 380415 V - 50 Hz.


- Thermal protectors are provided in the winding for connection to the external control panel

EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE


PVXC SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUST HEAVY GAUGE CAST IRON, RESISTANT TO ABRASION AND LONG LASTING, AND HAVE A VORTEX TYPE IMPELLER. THEY ARE SUITABLE FOR SEWAGE, WASTE WATER AND SLUDGE, INCLUDING WATER CONTAINING SOLIDS OR MUD. THEY ARE IDEAL FOR FIXED SEWAGE INSTALLATIONS, TUNNELS, UNDERGROUND CARPARKS, SUMPS AND SIMILAR APPLICATIONS.

INSULATION: class F.

PROTECTION: IP 68.

STANDARD FEATURES:
Base pedestal elbow (duct foot) Threaded delivery counterflange Top supports for guide tubes

PVXCm (single-phase) Float switch. PVXCm


10m H07 RN-F submersible power cable with Schuko plug. 1.1 to 1.5 kW models are supplied with control box with capacitor and manual reset motor protector. 2.2 kW models are supplied with control box type QES 300 MONO.

GUARANTEE 2 YEARS subject to our general terms of sale. PVXC

(three-phase) 10m H07 RN-F neoprene power cable

OPTIONS ON REQUEST

control box for three-phase pumps dual voltage: 230/400 V or 400/690 V single-phase versions without float switch other voltages or frequency 60 Hz

190

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PVXC30/50

PVXC20/50

PVXC15/50

Head H (metres)

PVXC30/70

PVXC20/70

PVXC15/70

Flow rate Q

TYPE
Single-phase PVXCm 15/50 PVXCm 20/50 PVXCm 30/50 PVXCm 15/70 PVXCm 20/70 PVXCm 30/70 Three-phase PVXC 15/50 PVXC 20/50 PVXC 30/50 PVXC 15/70 PVXC 20/70 PVXC 30/70

POWER
kW HP

m3/h l/min

0 0

6 100 10.5 12 15

12 200 9.5 11 14 5.5 7.4 9.7

18 300 8.2 9.5 13 5 6.7 9

21 350 7.2 9 12.3 4.7 6.3 8.6

24 400

27 450

30 500

36

42

48 800

51 850

54

60

66

72

600 700 2 4.5 8 3 4.5 6.7 2 5.9 2.2 3.6 5.8

900 1000 1100 1200

1.1 1.5 2.2 1.1 1.5 2.2

1.5 2 3 1.5 2 3

11.5 13 H metres 16 6.5 8.5 11

6.5 5.6 4.5 8 7,2 6.5 11.5 10.8 10 4.4 4 3.7 6 5.6 5.2 8.2 7.8 7.5

3.3 1.5 2.8 5

2 1 2.4 4.6

2 4.2

1 3.3

2.5

1.5

Q = Flow rate H = Total manometric head a

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


Typical installation

Guide tubes
external 27 mm maximum internal 19.521.5 mm

w
DN

n PORT
DN
passage of solid bodies

TYPE Single-phase Three-phase PVXCm 15/50 PVXC 15/50 PVXCm 20/50 PVXC 20/50 PVXCm 30/50 PVXC 30/50 PVXCm 15/70 PVXC 15/70 PVXCm 20/70 PVXC 20/70 PVXCm 30/70 PVXC 30/70

21/2"

21/2"
21/2" 3"

3"
3"

50 mm 50 mm 50 mm 70 mm 70 mm 70 mm

a 60 60 60 60 60 60 60

b 116 116 116 150 150 150

c 51 51 51 70 70 70

d 501 501 501 585 585 585

DIMENSIONS e f 62 270 62 270 62 270 95 300 95 300 95 300

d
mm g h m 10 387 200 387 10 387 200 10 397/387 200 10 10 405 256 405 10 405 256 10 415/405 256

kg* n w 1~ 3~ 120 72 42.0 40.0 120 72 43.8 42.3 120 72 49.7 43.8 150 92 53.0 50.7 150 92 54.9 53.0 150 92 61.1 55.2 (*weight including counterflange)

191

SINGLE-CHANNEL submersible pumps


for sewage water

stationary version
PMC series pumps are supplied complete with base pedestal elbow (with mating flange), pump slide bracket and guide tube top support, for fixed sewer installations.

RANGE OF PERFORMANCE Flow rate up to 1600 l/min (96 m3/h) Head up to 24 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 40C Passage of solid bodies max 50 mm for PMC 15-20-30/50 Passage of solid bodies max 70 mm for PMC 30/70 For continuous duty: minimum immersion 430 mm from pump base CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3 INSTALLATION AND USE
PMC SERIES PUMPS ARE MADE OF EXCEPTIONALLY ROBUST HEAVY GAUGE CAST IRON, ABRASION RESISTANT AND LONGLASTING, WITH A SINGLE-CHANNEL IMPELLER WHICH CAN HANDLE LIQUIDS WITH SUSPENDED SOLIDS AND SHORT FIBRES. THEY ARE IDEAL FOR SEWAGE, WASTE AND GROUND WATER, EVEN WITH SOLIDS OR MUD, AND ARE THEREFORE RECOMMENDED FOR BUILDING OR INDUSTRIAL EFFLUENT AND DRAINAGE OF LARGE AREAS SUCH AS CAR PARKS.

CONSTRUCTION CHARACTERISTICS

PUMP BODY, MOTOR CASING AND BASE PEDESTAL: cast iron. IMPELLER: single-channel, in cast iron. BASE: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057. DOUBLE SEAL: mechanical seal silicon carbide - widia - NBR, with oil barrier chamber and inner lip seal to protect the seal in the event of dry running. MOTOR: submersible asynchronous, 2 pole, for continuous duty. PMCm: single-phase 220240 V - 50 Hz Models up to 1.5 kW have built in thermal protection
- 2.2 kW single-phase versions have a thermal protector provided in the winding for connection to the control box.

PMC:

three-phase 380415 V - 50 Hz.


- Thermal protectors are provided in the winding for connection to the external control panel

INSULATION: class F.

PROTECTION: IP 68.

STANDARD FEATURES:
Base pedestal elbow (duct foot) Threaded delivery counterflange Top supports for guide tubes

PMCm PMCm (single-phase) Float switch.


10m H07 RN-F submersible power cable with Schuko plug. 1.1 to 1.5 kW models are supplied with control box with capacitor and manual reset motor protector. 2.2 kW models are supplied with control box type QES 300 MONO.

PMC GUARANTEE 2 YEARS subject to our general terms of sale.

(three-phase) 10m H07 RN-F neoprene power cable

OPTIONS ON REQUEST

control box for three-phase pumps dual voltage: 230/400 V or 400/690 V single-phase versions without float switch other voltages or frequency 60 Hz

192

CURVES AND PERFORMANCE DATA AT n= 2900 1/min

PMC30/50

PMC20/50 PMC15/50

Head H (metres)

PMC30/70

Flow rate Q

TYPE
Single-phase PMCm 15/50 PMCm 20/50 PMCm 30/50 PMCm 30/70 Three-phase PMC 15/50 PMC 20/50 PMC 30/50 PMC 30/70

POWER
kW HP

m3/h l/min

0 0

6 100 14 16 22

12 200

15 250

18 300

24 400 8.5 10.5 16 10.2

30 500 7 9 14 9.5

36 600 5 7 12 8.8

42

48

54

60

66

72

84

96

700 800 3 5 10 8.2 1 3 8 7.6

900 1000 1100 1200 1400 1600 1 6 6.8

1.1 1.5 2.2 2.2

1.5 2 3 3

16 H metres 18 24 13

12.5 11.5 10.5 14 13 12.5 20 19 18 11.5 11.2 11

4 6

2 5.3

4.8

3.2

Q = Flow rate H = Total manometric head

Tolerance of the performance curves according to EN ISO 9906 App. A.

DIMENSIONS AND WEIGHTS


a

Typical installation Guide tubes


external 27 mm maximum internal 19.521.5 mm

w
DN

TYPE Single-phase Three-phase PMCm 15/50 PMC 15/50 PMCm 20/50 PMC 20/50 PMCm 30/50 PMC 30/50 PMCm 30/70 PMC 30/70

PORT
DN

passage of solid bodies

21/2"

21/2"
21/2"

3"

50 mm 50 mm 50 mm 70 mm

a 60 60 60 60 60

b 116 116 116 150

c 51 51 51 70

d 501 501 501 585

DIMENSIONS e f 62 270 62 270 62 270 95 300

d
mm kg* g h m n w 1~ 3~ 10 387 200 120 72 43.0 40.8 387 10 387 200 120 72 44.7 43.0 10 10 397/387 200 120 72 50.7 44.8 10 415/405 256 150 92 62.0 56.1 (*weight including counterflange)

193

Pumps with electronic controller

Domestic pumps with a pressure sensing electronic controller for automatic operation; the pump operates as required as a tap is opened or closed. The controller also provides protection for the pump against dry running.

TYPE

POWER

DIMENSIONS mm

Single-phase
PKm 60 - EP PKm 65 - EP PKm 70 - EP PKm 80 - EP PKm 100 - EP PKSm 60 - EP PKSm 65 - EP PKSm 70 - EP PKSm 80 - EP CPm 150 - EP CPm 158 - EP CPm 170 - EP CPm 170M -EP 2CPm 25/130N - EP 2CPm 25/140H - EP 2CPm 25/140M - EP 2CPm 80E - EP 3CPm 80E - EP 4CPm 80E - EP 3CPm 100E - EP 4CPm 100E - EP JSWm 1C - EP JSWm 1B - EP JSWm 1A - EP JSWm 10H - EP JSWm 12H - EP JSWm 15H - EP JSWm 10M - EP JSWm 12M - EP JSWm 15M - EP JSWm 3CH - EP JSWm 3CM - EP JSWm 3CL - EP PLURIJETm 3/80 - EP PLURIJETm 4/80 - EP PLURIJETm 3/100 - EP PLURIJETm 4/100 - EP

kW 0.37 0.50 0.60 0.75 1.1 0.37 0.50 0.60 0.75 0.75 0.75 1.1 1.1 0.75 1.1 1.1 0.37 0.45 0.60 0.60 0.75 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.45 0.60 0.60 0.75

HP 0.50 0.70 0.85 1 1.5 0.50 0.70 0.85 1 1 1 1.5 1.5 1 1.5 1.5 0.50 0.60 0.85 0.85 1 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.60 0.85 0.85 1

Weight1.1 kg

Typical installation

COMPONENTS
- Single-phase electropump 230V - 50Hz - EASYPRESS controller - 1.5 metre cable with Schuko plug
*maximum height approx. 15 metres

* For correct operation of the EASYPRESS device, the height of the column of water must not exceed 15 metres.

194

Pumps with pressure switch sub-assembly

Pumps with pressure switch sub-assembly - ready to be connected to a pressure vessel for automatic operation.

PERFORMANCE
TYPE PORTS POWER FLOW RATE (1) Q l/min
32 40 50 50 32 40 50 50 90 100 100 140 50 60 60 100 100 45 50 50 50 50 50 80 80 80 70 120 160 50 50 50 50 50 50 80 80 80 1.4 1.5 1.8 2.2 1.4 1.5 1.8 2.2 1.8 1.4 2.2 2.2 1.0 1.4 2.2 1.4 2.0 1.2 1.4 1.8 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 1.2 1.4 1.8 2.0 2.4 3.0 1.4 2.0 2.5

PR COMPONENTS
SETTING (2) bar
2.8 3.0 3.2 3.6 2.8 3.0 3.2 3.6 3.2 2.8 3.6 3.6 2.2 2.8 3.6 2.8 3.5 2.6 2.8 3.2 3.4 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 2.6 2.8 3.2 3.4 3.8 4.0 2.8 3.5 4.0

Single-phase
PKm 60 - PR PKm 65 - PR PKm 70 - PR PKm 80 - PR PKSm 60 - PR PKSm 65 - PR PKSm 70 - PR PKSm 80 - PR CPm 158 - PR 2CPm 25/130N - PR 2CPm 25/140H - PR 2CPm 25/140M - PR 2CPm 80E - PR 3CPm 80E - PR 4CPm 80E - PR 3CPm 100E - PR 4CPm 100E - PR JSWm 1C - PR JSWm 1B - PR JSWm 1A - PR JSWm 10H - PR JSWm 12H - PR JSWm 15H - PR JSWm 10M - PR JSWm 12M - PR JSWm 15M - PR JSWm 3CH - PR JSWm 3CM - PR JSWm 3CL - PR JCRm 1C - PR JCRm 1B - PR JCRm 1A - PR JCRm 10H - PR JCRm 12H - PR JCRm 15H - PR JCRm 10M - PR JCRm 12M - PR JCRm 15M - PR

suc.
1 1 1 1 1 1 1 1 1 11/4" 11/4" 11/2" 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11/4" 11/4" 11/4" 1 1 1 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"

deliv.
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

kW 0.37 0.50 0.60 0.75 0.37 0.50 0.60 0.75 0.75 0.75 1.1 1.1 0.37 0.45 0.60 0.60 0.75 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1

HP 0.50 0.70 0.85 1 0.50 0.70 0.85 1 1 1 1.5 1.5 0.50 0.60 0.85 0.85 1 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5

Single-phase pump 230V - 50Hz Pressure switch Pressure gauge 3 or 5-way brass connector 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended pressure switch setting (2) Pressure switch recommended range

195

Small pressure sets with 24 litre spherical vessel, for automatic operation. Suitable for the supply of pressurised water in the home or in holiday homes.

PERFORMANCE AND DIMENSIONS


TYPE Single-phase
PKm 60 - 24 SF PKm 65 - 24 SF PKm 70 - 24 SF PKm 80 - 24 SF PKm 100 - 24 SF PKSm 60 - 24 SF PKSm 65 - 24 SF PKSm 70 - 24 SF PKSm 80 - 24 SF CPm 152 - 24 SF CPm 158 - 24 SF CPm 170 - 24 SF CPm 170M-24 SF 2CPm 25/130N - 24 SF 2CPm 25/140H - 24 SF 2CPm 25/140M - 24 SF 3CPm 80E - 24 SF 4CPm 80E - 24 SF 3CPm 100E- 24 SF 4CPm 100E- 24 SF 3CRm 80 - 24 SF 4CRm 80 - 24 SF 3CRm 100 - 24 SF JSWm 1C - 24 SF JSWm 1B - 24 SF JSWm 1A - 24 SF JSWm 10H - 24 SF JSWm 12H - 24 SF JSWm 15H - 24 SF JSWm 10M - 24 SF JSWm 12M - 24 SF JSWm 15M - 24 SF JSWm 3CH - 24 SF JSWm 3CM- 24 SF JSWm 3CL - 24 SF JCRm 1C - 24 SF JCRm 1B - 24 SF JCRm 1A - 24 SF JCRm 10H - 24 SF JCRm 12H - 24 SF JCRm 15H - 24 SF JCRm 10M - 24 SF JCRm 12M - 24 SF JCRm 15M - 24 SF
PORTS POWER FLOW RATE (1) SETTING (recommended) (2) DIMENSIONS mm

suc. deliv.

kW 0.37 0.50 0.60 0.75 1.1 0.37 0.50 0.60 0.75 0.55 0.75 1.1 1.1 0.75 1.1 1.1 0.45 0.60 0.60 0.75 0.45 0.60 0.60 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1

HP 0.50 0.70 0.85 1 1.5 0.50 0.70 0.85 1 0.75 1 1.5 1.5 1 1.5 1.5 0.60 0.85 0.85 1 0.60 0.85 0.85 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5

l/min
32 40 50 50 50 32 40 50 50 80 90 120 150 100 100 140 60 60 100 100 60 60 100 45 50 50 50 50 50 80 80 80 70 120 160 50 50 50 50 50 50 80 80 80

min

max

1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/2" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"

1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"

1.4 1.5 1.8 2.2 3.5 1.4 1.5 1.8 2.2 1.4 1.8 2.2 2.0 1.4 2.2 2.2 1.4 2.2 1.4 2 1.4 2.2 1.4 1.2 1.4 1.8 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 1.2 1.4 1.8 2.0 2.4 3.0 1.4 2.0 2.5

2.8 3.0 3.2 3.6 4.5 2.8 3.0 3.2 3.6 2.8 3.2 3.5 3.5 2.8 3.6 3.6 2.8 3.6 2.8 3.5 2.8 3.6 2.8 2.6 2.8 3.2 3.2 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 2.6 2.8 3.2 3.4 3.8 4.0 2.8 3.5 4.0

381 389 409 409 447 381 389 409 409 434 434 470 470 437 462 462 401 408 408 423 435 443 423 434 434 441 460 460 460 460 460 460 522 522 522 435 435 443 460 460 460 460 460 460

360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360

513 518 531 531 549 565 565 577 577 617 617 635 635 576 599 599 550 550 550 550 548 548 548 536 536 536 555 555 555 555 555 555 583 583 583 548 548 548 579 579 579 579 579 579

DN2

HYDROFRESH 24 SF COMPONENTS - Single-phase pump 230 V - 50 Hz - 24 litre spherical vessel - Pressure switch SQUARE-D - Pressure gauge - 3 or 5-way brass connector - 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended pressure switch settings (2) Pressure switch recommended rate

N.B. The pre-charge of air in diaphragm tanks must be set to a value 0.2 bar lower than the minimum setting of the pressure switch.

196

DN1

Small pressure sets with 20 litre cylindrical vessel, for automatic operation. Suitable for the supply of pressurised water in the home or in holiday homes.

PERFORMANCE AND DIMENSIONS


TYPE Single-phase
PKm 60 - 24 CL PKm 65 - 24 CL PKm 70 - 24 CL PKm 80 - 24 CL PKm 100 - 24 CL PKSm 60 - 24 CL PKSm 65 - 24 CL PKSm 70 - 24 CL PKSm 80 - 24 CL CPm 152 - 24 CL CPm 158 - 24 CL CPm 170 - 24 CL CPm 170M-24 CL 2CPm 25/130N - 24 CL 2CPm 25/140H - 24 CL 2CPm 25/140M - 24 CL 3CPm 80E - 24 CL 4CPm 80E - 24 CL 3CPm 100E- 24 CL 4CPm 100E- 24 CL 3CRm 80 - 24 CL 4CRm 80 - 24 CL 3CRm 100 - 24 CL JSWm 1C - 24 CL JSWm 1B - 24 CL JSWm 1A - 24 CL JSWm 10H - 24 CL JSWm 12H - 24 CL JSWm 15H - 24 CL JSWm 10M - 24 CL JSWm 12M - 24 CL JSWm 15M - 24 CL JSWm 3CH - 24 CL JSWm 3CM- 24 CL JSWm 3CL - 24 CL JCRm 1C - 24 CL JCRm 1B - 24 CL JCRm 1A - 24 CL JCRm 10H - 24 CL JCRm 12H - 24 CL JCRm 15H - 24 CL JCRm 10M - 24 CL JCRm 12M - 24 CL JCRm 15M - 24 CL
PORTS POWER FLOW RATE (1) SETTING (recommended) (2) DIMENSIONS mm

suc. deliv.

kW 0.37 0.50 0.60 0.75 1.1 0.37 0.50 0.60 0.75 0.55 0.75 1.1 1.1 0.75 1.1 1.1 0.45 0.60 0.60 0.75 0.45 0.60 0.60 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1

HP 0.50 0.70 0.85 1 1.5 0.50 0.70 0.85 1 0.75 1 1.5 1.5 1 1.5 1.5 0.60 0.85 0.85 1 0.60 0.85 0.85 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5

l/min
32 40 50 50 50 32 40 50 50 80 90 120 150 100 100 140 60 60 100 100 60 60 100 45 50 50 50 50 50 80 80 80 70 120 160 50 50 50 50 50 50 80 80 80

min

max

DN2

1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/2" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"

1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"

1.4 1.5 1.8 2.2 3.5 1.4 1.5 1.8 2.2 1.4 1.8 2.2 2.0 1.4 2.2 2.2 1.4 2.2 1.4 2 1.4 2.2 1.4 1.2 1.4 1.8 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 1.2 1.4 1.8 2.0 2.4 3.0 1.4 2.0 2.5

2.8 3.0 3.2 3.6 4.5 2.8 3.0 3.2 3.6 2.8 3.2 3.5 3.5 2.8 3.6 3.6 2.8 3.6 2.8 3.5 2.8 3.6 2.8 2.6 2.8 3.2 3.2 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 2.6 2.8 3.2 3.4 3.8 4.0 2.8 3.5 4.0

540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540

255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 265 265 265 315 315 315 315 315 315 290 290 290 255 255 255 255 255 255 255 255 255

475 480 490 490 510 540 540 550 550 580 580 595 595 538 562 562 510 510 510 510 509 509 509 497 497 497 515 515 515 515 515 515 545 545 545 509 509 509 539 539 539 539 539 539

DN1

HYDROFRESH 24 CL COMPONENTS - Single-phase pump - 20 litre cylindrical vessel - Hose - Pressure switch SQUARE-D - Pressure gauge - 3 or 5-way brass connector - 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended pressure switch setting (2) Pressure switch recommended rate

N.B. The pre-charge of air in diaphragm tanks must be set to a value 0.2 bar lower than the minimum setting of the pressure switch.

197

Pressure sets with 60 litre cylindrical vessel, for automatic operation. Suitable for the supply of pressurised water in the home.

PERFORMANCE AND DIMENSIONS


TYPE Single-phase
PKSm 80 - 60 CL CPm 158 - 60 CL CPm 170 - 60 CL CPm 170M-60 CL 2CPm 25/130N - 60 CL 2CPm 25/140H - 60 CL 2CPm 25/140M - 60 CL 4CPm 100E- 60 CL JSWm 10H - 60 CL JSWm 12H - 60 CL JSWm 15H - 60 CL JSWm 10M - 60 CL JSWm 12M - 60 CL JSWm 15M - 60 CL JSWm 3CH - 60 CL JSWm 3CM- 60 CL JSWm 3CL - 60 CL JCRm 10H - 60 CL JCRm 12H - 60 CL JCRm 15H - 60 CL JCRm 10M - 60 CL JCRm 12M - 60 CL JCRm 15M - 60 CL

PORTS

POWER

FLOW RATE (1)

SETTING (recommended) (2)

DIMENSIONS mm

suc. deliv.

kW 0.75 0.75 1.1 1.1 0.75 1.1 1.1 0.75 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.75 0.90 1.1 0.75 0.90 1.1

HP 1 1 1.5 1.5 1 1.5 1.5 1 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 1 1.25 1.5 1 1.25 1.5

l/min
50 90 120 150 100 100 140 100 50 50 50 80 80 80 70 120 160 50 50 50 80 80 80

min

max

DN2

1" 1" 11/4" 11/4" 11/4" 11/4" 11/2" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"

1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"

2.2 1.8 2.2 2.0 1.4 2.2 2.2 2 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 2.0 2.4 3.0 1.4 2.0 2.5

3.6 3.2 3.5 3.5 2.8 3.6 3.6 3.5 3.2 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 3.4 3.8 4.0 2.8 3.5 4.0

750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750

380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380 380

630 720 735 735 678 702 702 650 655 655 655 655 655 655 685 685 685 679 679 679 679 679 679
l a
DN1

HYDROFRESH60CLCOMPONENTS - Single-phase pump - 60 litre cylindrical vessel - Hose - Pressure switchSQUARE-D - Pressure gauge - 3 or 5-way brass connector - 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended pressure switch setting (2) Pressure switch recommended rate N.B. The pre-charge of air in diaphragm tanks must be set to a value 0.2 bar lower than the minimum setting of the pressure switch.

198

Pressure sets with 100 litre cylindrical vessel, for automatic operation. Suitable for the supply of pressurised water in the home.

PERFORMANCE AND DIMENSIONS


TYPE Single-phase
CPm 170
- 100 CL

PORTS

POWER

FLOW RATE (1)

SETTING (recommended) (2)

DIMENSIONS mm
DN2

suc. deliv.

kW 1.1 1.1 0.75 1.1 1.1 0.75 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.75 0.90 1.1 0.75 0.90 1.1

HP 1.5 1.5 1 1.5 1.5 1 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 1 1.25 1.5 1 1.25 1.5

l/min
120 150 100 100 140 100 50 50 50 80 80 80 70 120 160 50 50 50 80 80 80

min

max

11/4" 11/4"

1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"

2.2 2.0 1.4 2.2 2.2 2 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 2.0 2.4 3.0 1.4 2.0 2.5

3.5 3.5 2.8 3.6 3.6 3.5 3.2 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 3.4 3.8 4.0 2.8 3.5 4.0

860 860 860 860 860 860 860 860 860 860 860 860 860 860 860 860 860 860 860 860 860

450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450

800 800 767 767 715 720 720 720 720 720 720 750 750 750 744 744 744 744 744 744
l a
DN1

CPm 170M - 100 CL

2CPm 25/130N - 100 CL 11/4" 2CPm 25/140H - 100 CL 11/4" 2CPm 25/140M -100 CL 11/2" 4CPm 100E - 100 CL JSWm 10H - 100 CL JSWm 12H - 100 CL JSWm 15H - 100 CL JSWm 10M - 100 CL JSWm 12M - 100 CL JSWm 15M - 100 CL JSWm 3CH - 100 CL JSWm 3CM - 100 CL JSWm 3CL - 100 CL JCRm 10H - 100 CL JCRm 12H - 100 CL JCRm 15H - 100 CL JCRm 10M - 100 CL JCRm 12M - 100 CL JCRm 15M - 100 CL 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"

743
h

HYDROFRESH 100 CL COMPONENTS - Single-phase pump - 100 litre cylindrical vessel - Hose - Pressure switch SQUARE-D - Pressure gauge - 3 or 5-way brass connector - 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended pressure switch setting (2) Pressure switch recommended rate N.B. The pre-charge of air in diaphragm tanks must be set to a value 0.2 bar lower than the minimum setting of the pressure switch.

199

Pressure Boosting Sets

CB2-F

CB2-VL

CB2-CP

CB2-2CP

CB2-JSW

COMBIPRESS are twin pump sets for water pressurisation, with a range to suit the requirements of domestic, civil agricultural and industrial applications.

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS

PRINCIPLE OF OPERATION
COMBIPRESS pressure booster sets are pre-assembled ready for

installation. The sets operate as duty-assist, with one or both pumps starting automatically in succession as demand for water increases. This system is energy efficient as it only starts the pumps necessary to meet the demand. The lead pump is alternated automatically by the control panel.

USE
Clean water and chemically non aggressive liquids. - Water supply: pressure boosting for industry, condominiums, hotels, communities, water treatment plants, camping sites, schools, hospitals, barracks, etc. - Irrigation: football and sports grounds, golf courses, agriculture and artifical snow systems.

PUMPS complete with suction and delivery manifolds, ball valves and non return valves. BASE made of powder-painted metal sections. Control systems pre-installed on the delivery manifold, comprising of pressure gauge, connection for pressure vessel (not supplied), and two user adjustable pressure switches. The factory settings are shown in the following tables. CONTROL PANEL with door interlocked power switch, low voltage pressure switch control circuit, automatic pump changeover, thermal motor protector and anti-bounce system to ensure that the pumps run for an acceptable period once started. CB2m: single-phase 230 V - 50 Hz including capacitor, and with integral thermal overload protection. CB2: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 18.5 kW.

200

sets with two single-stage centrifugal pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - CPm 150 CB2 - CPm 158 CB2 - CPm 170 CB2 - CPm 170M CB2 - CPm 190 Three-phase CB2 - CP 150 CB2 - CP 158 CB2 - CP 170 CB2 - CP 170M CB2 - CP 190 CB2 - CP 200
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 14.4 10.8 14.4 19.2 16.8 18 l/min 240 180 240 320 280 300

MAXIMUM HEAD metres 29.5 36 41 36 50 58

PRESSURE SWITCH FACTORY SETTING

-1bar 1.52.5 23 23 23 34 45

-2bar 12 1.52.5 1.52.5 1.52.5 2.53.5 3.54.5

0.75 + 0.75 0.75 + 0.75 1.1 + 1.1 1.1 + 1.1 1.5 + 1.5 2.2 + 2.2

1+1 1+1 1.5 + 1.5 1.5 + 1.5 2+2 3+3

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

201

sets with two single-stage centrifugal pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Three-phase CB2 - CP 220C CB2 - CP 220B CB2 - CP 220A CB2 - CP 220AH
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 54 54 54 54 l/min 900 900 900 900

MAXIMUM HEAD metres 32 38 49 52

PRESSURE SWITCH FACTORY SETTING

-1bar 1.52.5 2.53.5 34 3.54.5

-2bar 12 23 2.53.5 34

2.2 + 2.2 3+3 4+4 5.5 + 5.5

3+3 4+4 5.5 + 5.5 7.5 + 7.5

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

202

sets with two single-stage centrifugal pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - CPm 25/160B CB2 - CPm 25/160A CB2 - CPm 25/200B Three-phase CB2 -CP 25/160B CB2 - CP 25/160A CB2 - CP 25/160AR CB2 - CP 25/200B
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 24 26.4 26.4 26.4 l/min 400 440 440 440

MAXIMUM HEAD metres 33 38 42 49

PRESSURE SWITCH FACTORY SETTING

-1bar 1.52.5 23 2.53.5 3.54.5

-2bar 12 1.52.5 23 34

1.1 + 1.1 1.5 + 1.5 2.2 + 2.2 2.2 + 2.2

1.5 + 1.5 2+2 3+3 3+3

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

203

sets with two twin-stage centrifugal pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - 2CPm 25/130N CB2 - 2CPm 25/140H CB2 - 2CPm 25/140M CB2 - 2CPm 25/160B Three-phase CB2 - 2CP 25/130N CB2 - 2CP 25/140H CB2 - 2CP 25/140M CB2 - 2CP 25/160B CB2 - 2CP 25/160A CB2 - 2CP 32/200C
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 12 10.8 15 18 19.2 27.6 l/min 200 180 250 300 320 460

MAXIMUM HEAD metres 42 54 47 58 68 70

PRESSURE SWITCH FACTORY SETTING

-1bar 23 3.54.5 34 3.54.5 45 4.55.5

-2bar 1.52.5 34 2.53.5 34 3.54.5 45

0.75 + 0.75 1.1 + 1.1 1.1 + 1.1 1.5 + 1.5 2.2 + 2.2 3+3

1+1 1.5 + 1.5 1.5 + 1.5 2+2 3+3 4+4

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

204

sets with two twin-stage centrifugal pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Three-phase CB2 - 2CP 32/200B CB2 - 2CP 32/210B CB2 - 2CP 32/210A CB2 - 2CP 40/180C CB2 - 2CP 40/180B CB2 - 2CP 40/180A
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 27.6 26.4 26.4 38.4 48 48 l/min 460 440 440 640 800 800

MAXIMUM HEAD metres 85 94 112 64 76 88

PRESSURE SWITCH FACTORY SETTING

-1bar 67 78 910 4.55.5 56 67

-2bar 5.56.5 6.57.5 8.59.5 45 4.55.5 5.56.5

4+4 5.5 + 5.5 7.5 + 7.5 4.0 + 4.0 5.5 + 5.5 7.5 + 7.5

5.5 + 5.5 7.5 + 7.5 10 + 10 5.5 + 5.5 7.5 + 7.5 10 + 10

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

205

sets with two multi-stage pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - 3CPm 80E CB2 - 3CPm100E CB2 - 4CPm 80E CB2 - 4CPm100E
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 7.2 12 7.2 10.8 l/min 120 200 120 180

MAXIMUM HEAD metres 38 36 50 46

PRESSURE SWITCH FACTORY SETTING

-1bar 23 23 34 34

-2bar 1.52.5 1.52.5 2.53.5 2.53.5

0.45 + 0.45 0.60 + 0.60 0.60 + 0.60 0.75 + 0.75

0.60 + 0.60 0.85 + 0.85 0.85 + 0.85 1+1

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

206

sets with two multi-stage pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - 3CRm 80 CB2 - 3CRm 100 CB2 - 4CRm 80
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 7.2 12 7.2 l/min 120 200 120

MAXIMUM HEAD metres 38 36 50

PRESSURE SWITCH FACTORY SETTING

-1bar 23 23 34

-2bar 1.52.5 1.52.5 2.53.5

0.45 + 0.45 0.60 + 0.60 0.60 + 0.60

0.60 + 0.60 0.85 + 0.85 0.85 + 0.85

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

207

sets with two self-priming pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - JSWm 10M CB2 - JSWm 12M CB2 - JSWm 3CM CB2 - JSWm 3BM Three-phase CB2 - JSW 3CM CB2 - JSW 3BM CB2 - JSW 3AM CB2 - JSW 3AL
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 9.6 9.6 12 14.4 14.4 19.2 l/min 160 160 200 240 240 320

MAXIMUM HEAD metres 46 50 52 60 74 62

PRESSURE SWITCH FACTORY SETTING

0.75 + 0.75 0.90 + 0.90 1.1 + 1.1 1.5 + 1.5 2.2 + 2.2 2.2 + 2.2

1+1 1.25 + 1.25 1.5 + 1.5 2+2 3+3 3+3

-1bar 23 2.53.5 34 3.54.5 45 45

-2bar 1.52.5 23 2.53.5 34 3.54.5 3.54.5

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

208

sets with two self-priming pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - JCRm 10M CB2 - JCRm 12M
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h l/min

MAXIMUM HEAD metres

PRESSURE SWITCH FACTORY SETTING

-1bar

-2bar

0.75 + 0.75 0.90 + 0.90

1+1 1.25 + 1.25

9.6 9.6

160 160

46 50

23 2.53.5

1.52.5 23

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

209

sets with two single-stage centrifugal pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Three-phase CB2 - F 32/200C CB2 - F 32/200B CB2 - F 32/200A CB2 - F 40/200B CB2 - F 40/200A CB2 - F 50/200C
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 54 60 60 84 84 204 l/min 900 1000 1000 1400 1400 3400

MAXIMUM HEAD metres 46 54 60 48 56 44

PRESSURE SWITCH FACTORY SETTING

-1bar 34 3.54.5 4.55.5 34 3.54.5 34

-2bar 2.53.5 34 45 2.53.5 34 2.53.5

4+4 5.5 + 5.5 7.5 + 7.5 5.5 + 5.5 7.5 + 7.5 11 + 11

5.5 + 5.5 7.5 + 7.5 10 + 10 7.5 + 7.5 10 + 10 15 + 15

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

210

sets with two single-stage centrifugal pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Three-phase CB2 - F 50/200B CB2 - F 50/200A CB2 - F 50/250D CB2 - F 50/250C CB2 - F 50/250B CB2 - F 50/250A
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 204 216 108 108 120 120 l/min 3400 3600 1800 1800 2000 2000

MAXIMUM HEAD metres 52 61 51 59 72 85

PRESSURE SWITCH FACTORY SETTING

-1bar 3.54.5 4.55.5 3.54.5 4.55.5 5.56.5 78

-2bar 34 45 34 45 56 6.57.5

15 + 15 18.5 + 18.5 9.2 + 9.2 11 + 11 15 + 15 18.5 + 18.5

20 + 20 25 + 25 12.5 + 12.5 15 + 15 20 + 20 25 + 25

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

211

sets with two single-stage centrifugal pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Flow rate Q

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Three-phase CB2 - F 65/200B CB2 - F 65/200A
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 240 252 l/min 4000 4200

MAXIMUM HEAD metres 45 51

PRESSURE SWITCH FACTORY SETTING

-1bar 34 3.54.5

-2bar 2.53.5 34

15 + 15 18.5 + 18.5

20 + 20 25 + 25

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

212

sets with two vertical multi-stage pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - VLm 2/7 CB2 - VLm 2/11 CB2 - VLm 2/15 CB2 - VLm 2/18 Three-phase CB2 - VL 2/7 CB2 - VL 2/11 CB2 - VL 2/15 CB2 - VL 2/18
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 7.8 7.8 7.2 7.2 l/min 130 130 120 120

MAXIMUM HEAD metres 60 75 90 105

PRESSURE SWITCH FACTORY SETTING

-1bar 3.54.5 56 6.57.5 78

-2bar 34 4.55.5 67 6.57.5

0.75 + 0.75 1.1 + 1.1 1.5 + 1.5 1.8 + 1.8

1+1 1.5 + 1.5 2+2 2.5 + 2.5

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

213

sets with two vertical multi-stage pumps


CURVES AND PERFORMANCE DATA AT n= 2900 1/min

Head H (metres)

Head H (metres)

1 pompa

2 pompe

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Head H (metres)

1 pompa

2 pompe

Flow rate Q

Flow rate Q

Head H (metres)

1 pompa

2 pompe

Flow rate Q Tolerance of the performance curves according to EN ISO 9906 App. A.

TYPE
Single-phase CB2 - VLm 4/7 CB2 - VLm 4/11 CB2 - VLm 4/15 CB2 - VLm 4/18 Three-phase CB2 - VL 4/7 CB2 - VL 4/11 CB2 - VL 4/15 CB2 - VL 4/18 CB2 - VL 4/22
kW

POWER
HP

MAXIMUM FLOW RATE* m3/h 13.2 13.2 12 10.8 10.8 l/min 220 220 200 180 180

MAXIMUM HEAD metres 50 60 75 90 105

PRESSURE SWITCH FACTORY SETTING

-1bar 2.53.5 3.54.5 4.55.5 67 78

-2bar 23 34 45 5.56.5 6.57.5

0.75 + 0.75 1.1 + 1.1 1.5 + 1.5 1.8 + 1.8 2.2 + 2.2

1+1 1.5 + 1.5 2+2 2.5 + 2.5 3+3

* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -

214

DIMENSIONS AND WEIGHTS


g g d d
DN2 DN2

DN1 DN1

h a b

h a b

CB2 - CP

CB2 - 2CP

DN2

DN1

h b

CB2 - 3-4CP
TYPE Single-phase CB2 - CPm 150 CB2 - CPm 158 CB2 - CPm 170 CB2 - CPm 170M CB2 - CPm 190 CB2 - CPm 25/160B CB2 - CPm 25/160A CB2 - CPm 25/200B CB2 - 2CPm 25/130N CB2 - 2CPm 25/140H CB2 - 2CPm 25/140M CB2 - 2CPm 25/160B CB2 - 3CPm 80E CB2 - 3CPm 100E CB2 - 4CPm 80E CB2 - 4CPm 100E Three-phase CB2 - CP 150 CB2 - CP 158 CB2 - CP 170 CB2 - CP 170M CB2 - CP 190 CB2 - CP 200 CB2 - CP 220C CB2 - CP 220B CB2 - CP 220A CB2 - CP 220AH CB2 - CP 25/160B CB2 - CP 25/160A CB2 - CP 25/160AR CB2 - CP 25/200B CB2 - 2CP 25/130N CB2 - 2CP 25/140H CB2 - 2CP 25/140M CB2 - 2CP 25/160B CB2 - 2CP 25/160A CB2 - 2CP 32/200C CB2 - 2CP 32/200B CB2 - 2CP 32/210B CB2 - 2CP 32/210A CB2 - 2CP 40/180C CB2 - 2CP 40/180B CB2 - 2CP 40/180A PORTS
DN1 DN2

11/2" 11/2" 11/2" 2" 2" 2" 2" 2" 100 100 100 100 100 2" 2" 2" 2" 2" 11/2" 2" 2" 2" 2" 2" 3" 3" 3" 3" 3" 4" 100 4" 4" 11/2" 11/2" 11/2" 11/2" 11/2"

11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 80 80 80 80 80 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2"" 11/2 11/2" 11/2" 2" 2" 2" 2" 2" 3" 80 3" 3" 11/2" 11/2" 11/2" 11/2" 11/2"

a 520 520 520 615 615 615 615 615 700 700 700 700 700 615 615 615 615 615 520 615 615 615 615 615 700 700 700 700 700 700 700 520 520 520 520 520

b 560 560 560 625 625 625 625 625 1000 1000 1000 1000 1000 645 645 645 645 645 600 595 596 670 625 910 910 910 920 920 920 980 980 980 600 596 595 670

c 620 620 620 630 630 630 630 630 780 780 780 780 780 630 630 630 680 620 630 630 630 630 630 780 780 780 895 895 895 780 780 780 620 630 630 630

DIMENSIONS mm d e 255 160 160 255 255 160 280 190 280 280 190 190 300 190 300 300 190 430 220 430 220 430 220 430 220 430 220 320 180 320 180 320 180 320 180 350 200 300 155 330 170 170 350 170 340 190 385 130 400 200 400 400 200 200 430 200 430 430 200 420 210 420 420 210 420 210 300 155 350 170 170 330 170 340 190

kg f 450 450 450 480 480 480 520 520 520 650 650 650 650 650 480 480 480 480 530 420 455 445 495 490 600 600 600 590 590 590 610 610 610 420 445 455 495 g 500 500 500 500 500 500 500 700 700 700 700 700 500 500 500 500 500 500 500 500 500 700 700 700 700 700 700 700 700 500 500 500 500 500 h 305 305 305 370 370 370 370 370 560 560 560 560 560 370 370 370 370 370 305 370 370 370 370 370 565 565 565 565 565 565 565 565 305 305 305 305 305 1~ 45.0 45.0 65.0 65.0 77.0 70.0 70.0 85.5 51.0 67.5 67.5 77.5 51.0 67.5 67.5 77.5 3~ 43.8 45.5 64.3 64.3 76.0 80.0 173.0 175.0 181.0 181.0 69.0 69.0 70.0 83.0 50.5 67.0 67.0 77.0 80.0 119.0 125.0 156.0 163.0 175.0 185.0 195.0 -

215

DIMENSIONS AND WEIGHTS

g d
DN2

DN2

h b

h b

CB2 - 3-4CR

CB2 - JSW

g g d
DN2 DN2

DN1

DN1

h b a

h b

CB2 - JCR

CB2 - F

TYPE Single-phase CB2 - 3CRm 80 CB2 - 3CRm100 CB2 - 4CRm 80 CB2 - JSWm 10M CB2 - JSWm 12M CB2 - JSWm 3CM CB2 - JSWm 3BM CB2 - JCRm 10M CB2 - JCRm 12M Three-phase CB2 - JSW 3CM CB2 - JSW 3BM CB2 - JSW 3AM CB2 - JSW 3AL CB2 - F 32/200C CB2 - F 32/200B CB2 - F 32/200A CB2 - F 40/200B CB2 - F 40/200A CB2 - F 50/200C CB2 - F 50/200B CB2 - F 50/200A CB2 - F 50/250D CB2 - F 50/250C CB2 - F 50/250B CB2 - F 50/250A CB2 - F 65/200B CB2 - F 65/200A

PORTS
DN1 DN2

11/2" 11/2" 1/2 11/2"" 11/2" 11/2" 2" 2" 2" 2" 2" 11/2" 11/2" 11/2" 4" 4" 100 4" 4" 4" 125 125 125 125 125 125 125 150 150 150

11/2" 11/2" 1/2 11/2"" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 3" 3" 80 3" 3" 3" 100 100 100 100 100 100 100 125 125 125

a 520 520 520 520 520 520 520 520 520 520 520 520 700 700 700 700 700 800 800 800 800 800 800 800 800 800 800

b 600 596 595 630 630 630 710 710 710 710 710 700 700 700 910 910 910 920 920 920 1200 1200 1200 1200 1200 1200 1200 1300 1300 1300

c 620 630 630 630 620 620 620 620 620 620 620 620 620 780 780 780 895 780 895 1330 1330 1330 1330 1330 1330 1330 1330 1330

DIMENSIONS mm d e 300 155 350 170 170 330 170 340 220 220 340 340 220 400 230 400 230 400 230 400 230 400 230 350 210 210 350 350 210 440 230 440 230 440 230 440 230 440 230 450 310 450 310 450 310 450 330 450 330 330 450 330 450 330 520 320 520 320 520 320

kg f 420 445 455 400 400 400 425 425 425 425 425 420 420 420 660 660 660 660 660 725 725 725 770 770 770 770 770 800 800 800 g 500 500 500 500 500 500 500 500 500 500 500 500 700 700 700 700 700 700 800 800 800 800 800 800 800 800 780 780 780 h 305 305 305 305 305 305 305 305 305 305 305 565 565 565 565 565 700 700 700 700 700 700 700 700 700 1~ 51.0 67.5 67.5 48.0 48.0 78.5 78.5 41.0 41.0 3~ 76.5 76.5 78.5 78.5 161.0 173.0 181.0 182.0 189.0 383.0 415.0 440.0 398.0 408.0 442.0 468.0 455.0 475.0

216

DN1

DN1

DIMENSIONS AND WEIGHTS

g d
DN2

DN1

h a b

CB2 - VL

TYPE Single-phase CB2 - VLm 2/7 CB2 - VLm 2/11 CB2 - VLm 2/15 CB2 - VLm 2/18 CB2 - VLm 4/7 CB2 - VLm 4/11 CB2 - VLm 4/15 CB2 - VLm 4/18 Three-phase CB2 - VL 2/7 CB2 - VL 2/11 CB2 - VL 2/15 CB2 - VL 2/18 CB2 - VL 4/7 CB2 - VL 4/11 CB2 - VL 4/15 CB2 - VL 4/18 CB2 - VL 4/22 2" 2" 2" 2" 2" 2" 2" 2" 2"

PORTS
DN1 DN2

2" 2" 2" 2" 2" 2" 2" 2" 2"

a 615 615 615 615 615 615 615 615 615

b 700 700 700 700 700 700 700 700 700 700

c 835 908 938 1000 835 880 880 880 938 1000

DIMENSIONS mm d e 500 130 500 140 500 140 500 140 500 500 130 500 140 500 140 140 500 140 500 140

kg f 765 838 868 943 765 810 810 810 868 943 g 350 350 350 350 350 350 350 350 350 350 h 370 370 370 370 370 370 370 370 370 370 1~ 65.3 76.0 78.0 80.0 65.3 75.0 77.0 79.0 3~ 63.8 71.0 74.0 76.0 63.8 70.0 73.0 75.0 87.0

217

asynchronous single-phase electric motors

Asynchronous single-phase electric motors, high quality, robust and with high efficiencies.

RATED POWERS AT 50 Hz 0.25 2.2 kW (0.33 3 HP) 2 pole 0.37 1.5 kW (0.50 2 HP) 4 pole LIMITS OF USE Rated voltage 5% Environment temperature up to +40 C Altitude up to 1000 metres a.s.l. CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 34-1 CEI 2-3
CE I 1110

GUARANTEE 2 YEARS subject to our general terms of sale. CONSTRUCTION CHARACTERISTICS

the motor casing is made of die-cast aluminium with a top terminal box containing the capacitor and power cable connections. the stator pack is made of magnetic sheet metal with a low loss figure. the stator is machine wound using class H double insulated wire with the head precision tied and shaped. Resin impregnation is carried out in a continuous automated process using class F polyester resin for reliable insulation and optimum heat transmission. MOTOR CASING: aluminium SHIELDS: die-cast aluminium. SHIELD: fan end in technopolymer for motor H 56. FAN: in glass-filled thermoplastic. ROTOR: die-cast, dynamically balanced, with shielded bearings, greased for life. TERMINAL BOX: with cable clamp. CAPACITOR: permanent, to standard VDE-IMQ. INSULATION: class F. PROTECTION: IP 44 complying with IEC 34-5 BALANCING: complying degree N of standard IEC 34-14. PAINTING: the surface protection of the motor is obtained through a process of pickling, phosphating, passivation and a two coat electrostatic paint, oven cured. Km 1: single-phase 230 V - 50 Hz.

MOTOR: The asynchronous single-phase motors of the Km1 series are of closed type, with external ventilation and permanent capacitor, suitable for continuous duty.

OPTIONS ON REQUEST

protection IP 55 different voltages motors for frequency 60 Hz

218

TECHNICAL CHARACTERISTICS
TYPE Rated power Revs Rated current A Condenser capacity F Power factor cos Yield Static torque Rated torque Static current Rated current J WEIGHT

kW

HP

1/min

kgm2

kg

2 POLE SINGLE-PHASE - 230 V - 50 Hz Km1 - 56 A/2 0.25 0.33 2730 Km1 - 63 B/2 0.37 0.50 2730 Km1 - 71 A/2 0.37 0.50 2800 Km1 - 71 B/2 0.55 0.75 2800 Km1 - 71 C/2 0.75 1 2800 Km1 - 80 B/2 1.1 1.5 2800 Km1 - 80 C/2 1.5 2 2800 Km1 - 90 S/2 1.5 2 2850 Km1 - 90 LB/2 2.2 3 2840 4 POLE SINGLE-PHASE - 230 V - 50 Hz Km1 - 71 B/4 Km1 - 80 A/4 Km1 - 80 B/4 Km1 - 90 S/4 Km1 - 90 LA/4 0.37 0.55 0.75 1.1 1.5 0.50 0.75 1 1.5 2 1380 1400 1400 1420 1420

1.8 2.75 3.0 4.2 5.2 7.5 9.7 9.6 16.0

8 12.5 10 20 25 35 45 45 50

0.90 0.90 0.83 0.86 0.93 0.90 0.93 0.93 0.83

63% 67% 65% 66% 68% 72% 74% 74% 76%

0.70 0.70 0.72 0.70 0.71 0.77 0.70 0.72 0.70

2.5 3.1 3.4 3.0 3.2 3.3 3.5 3.6 3.6

0.00020 0.00035 0.00045 0.00053 0.00058 0.00120 0.00140 0.00130 0.00260

3.35 4.6 6.8 8.0 8.0 11.6 12.6 15.7 17.2

3.1 4.5 5.5 7.8 10.8

14 20 25 31.5 40

0.91 0.93 0.95 0.98 0.95

62% 62% 65% 67% 70%

0.75 0.78 0.73 0.72 0.75

2.6 2.6 2.7 2.6 2.8

0.00073 0.00220 0.00280 0.00370 0.00490

7.8 9.8 11.5 14.0 17.0

DIMENSIONS
FRAME SIZE B3 (IM 1001)
l e e

FRAME SIZE B5 (IM 3001)


l

hd

ha

p n d

ga

bc c b bb

k ba

aa a ab f

s t la

ga

FRAME SIZE B14 (IM 3601)


l e

C E Italian Electrical I 1110 C o m m i t t e e


p1 n1 d

m1

Authorisation n prot. 1064 / 27.3.87

t1

s1

TYPE

DIMENSIONS mm
c
36 40 45 45 45 50 50 60 56 56 56

2 Pole Km1-56 A/2 Km1-63 B/2 Km1-71 A/2 Km1-71 B/2 Km1-71 C/2 Km1-80 B/2 Km1-80 C/2 Km1-90 S/2 Km1-90 LB/2

4 Pole a aa ab b ba bb bc 90 20 110 71 20 90 10.5 100 22 120 80 23.5 98 9 112 23 134 90 24.5 110 10 Km1-71 B/4 112 23 134 90 24.5 110 10 112 23 134 90 24.5 110 10 Km1-80 A/4 125 27.5 152 100 32 124 12 Km1-80 B/4 125 27.5 152 100 32 124 12 125 27.5 152 100 32 124 12 Km1-90 S/4 140 30 170 100 32.5 125 12.5 Km1-90 LA/4 140 30 170 125 32.5 150 12.5 140 30 170 125 32.5 150 12.5

d
9 11 14 14 14 19 19 19 24 24 24

e
20 23 30 30 30 40 40 40 50 50 50

f
3 4 5 5 5 6 6 6 8 8 8

ga
10.2 12.5 16 16 16 21.5 21.5 21.5 27 27 27

h
56 63 71 71 71 80 80 80 90 90 90

ga

ha
8 8 8 8 8

hd
121 152

he
65 91

k
7 7 7 7 9 9 9 9 9 9

l
209 243 243 243

la
8 9 9 9 9

m
100 115 130 130 130

m1
65 75 85 85 85

n
80 95 110 110 110

n1

p1

s
7 9 9.5 9.5 9.5

s1
M5 M5

t
3 3

t1
2.5

14 181

50 120 80 60 140 90 70 160 105 70 160 105 70 160 105

2.5 49.5 61 61 61 69 69 69 75 75 75

162.5 91.5 162.5 91.5 162.5 91.5

M6 3.5 2.5 M6 3.5 2.5 M6 3.5 2.5 3 3 3 3 3 3

10 202.5 122.5 10 202.5 122.5 10 202.5 122.5 10 218.5 128.5 10 218.5 128.5 10 218.5 128.5

279 10.5 165 100 130 279 10.5 165 100 130 299 10.5 165 100 130 297 10 322 10 322 10 165 115 130 165 115 130 165 115 130

80 200 120 11.5 M6 3.5 80 200 120 11.5 M6 3.5 80 200 120 11.5 M6 3.5 95 200 140 11.5 M8 3.5 95 200 140 11.5 M8 3.5 95 200 140 11.5 M8 3.5

219

he

he

z
45

ACCESSORIES
SPHERICAL TANK
TYPE 24 SF
Maximum working pressure 8 bar. Replaceable diaphragm in butyl rubber.

FITTING

CAPACITY 24 litres

1"

CYLINDRICAL TANKS
TYPE 24 CL 60 CL 100 CL 200 CL 300 CL
Maximum working pressure 10 bar. Replaceable diaphragm in butyl rubber.

FITTING

CAPACITY 20 litres 60 litres 100 litres 200 litres 300 litres

1" 1" 1" 11/2" 11/2"

VERTICAL TANKS
TYPE 8 VT 18 VT 60 VT 100 VT 200 VT 300 VT 500 VT
Maximum working pressure 10 bar. Replaceable diaphragm in butyl rubber.

FITTING

CAPACITY 8 litres 18 litres 60 litres 100 litres 200 litres 300 litres 500 litries

1" 1" 1" 1" 11/2" 11/2" 11/2"

SPHERICAL KIT
TYPE KS 24
24 litre spherical tank pressure gauge 0 6 bar 5-way fitting - 1" gas pressure switch SQUARE D
Maximum working pressure 8 bar. Replaceable diaphragm in butyl rubber.

220

ACCESSORIES
CYLINDRICAL KIT
TYPE KC 24
20 litre cylindrical tank pressure gauge 0 6 bar 5-way fitting - 1" gas pressure switch SQUARE D hose 1" gas (600 mm)
Maximum working pressure 10 bar. Replaceable diaphragm in butyl rubber.

TYPE KC 60
60 litre cylindrical tank pressure gauge 0 6 bar 5-way fitting - 1" gas pressure switch SQUARE D hose 1" gas (600 mm)

AUTOMATIC AIR FEEDERS


TYPE AIRFLO 1 AIRFLO 2
SUITABLE FOR TANKS: 100 500 litres 600 1000 litres

Automatic air feeders suitable for maintaining the air cushion in pressure vessels without diaphragm

3-WAY NIPPLE FOR AIR FEEDERS


TYPE NA 1.00 NA 1.25 NA 1.50 NA 2.00
FITTING 1" x 1" 11/4" x 11/4" 11/2" x 11/2" 2" x 2" DOUBLE CENTRAL FITTING
1/2" 1/2" 1/2" 1/2"

x 1/4" (male/female) x 1/4" (male/female) x 1/4" (male/female) x 1/4" (male/female)

3-way brass fittings for connections with air feeders (AIRFLO)

PRESSURE SWITCHES
TYPE FSG2 FYG 22 FYG 32 PM/5 PM/5 SK(1)
* Adjustable (1) Approved pressure switch

MANUFACTURER
SQUARE D SQUARE D SQUARE D ITALTECNICA ITALTECNICA

STANDARD SETTING* 1.4 2.8 bar 5.4 7.0 bar 8 10.5 bar 1.4 2.8 bar 1.4 2.8 bar

221

ACCESSORIES
PRESSURE GAUGES
TYPE MC 6 MR 6 MR 10
FITTING
1/4" - central 1/4" - radial 1/4" - radial

DIAMETER 50 mm 63 mm 63 mm

SCALE 0 6 bar 0 6 bar 0 10 bar

PRESSURE GAUGES GLYCERINE FILLED


TYPE MCG 6 MRG 6 MRG 10
FITTING 1/4" - central 1/4" - radial 1/4" - radial DIAMETER 50 mm 63 mm 63 mm SCALE 0 6 bar 0 6 bar 0 10 bar

3 - 5 WAY FITTINGS
TYPE R 3 - 3 way R 5 - 5 way
R 3: three-way fittings in moulded brass with 1" gas.connections R 5: five-way fittings in moulded brass with 1" gas and 1/4" gas connections.

FITTING 1" 1"

HOSES
TYPE TF 5 TF 6 TF 10
PIPE 1" 1" 1" FITTINGS 1" X 1" 1" X 1" 1" X 1" LENGTH 500 mm 600 mm 1000 mm

Hoses with 1" gas male/female fittings, in non-toxic EPDM rubber reinforced on the outside with blue spiral galvanised steel wire suitable for cold water. Maximum working pressure 10 bar.

HOSES COMPLETE WITH ELBOW


TYPE TFG 5 TFG 6
PIPE
3/4"

FITTINGS 1" X 1" 1" X 1"

LENGTH 500 mm 600 mm

1"

Hoses with 1" gas male/female fittings, in non-toxic EPDM rubber reinforced on the outside with blue spiral galvanised steel wire suitable for cold water. Maximum working pressure 10 bar.

222

ACCESSORIES
*ELECTRONIC PUMP CONTROLLERS execution
TYPE
EKO EASYPRESS
VOLT 230 10% Hz 50/60

approved
CURRENT max 6 A FITTINGS 1 x 1 FLOW RATE 8 m3/h

The pressure generated by the pump must be minimum 2.5 bar and maximum 10 bar. The column of water between the appliance and the highest user must not exceed 6 metres. Liquid temperature up to +60C. Protection IP 65.

TYPE
EASYPRESS

VOLT 230 10%

Hz 50/60

CURRENT max 8 A

FITTINGS 1 x 1

FLOW RATE 10 m3/h

The pressure generated by the pump must be minimum 3 bar and maximum 10 bar. The column of water between the appliance and the highest user must not exceed 15 metres. Liquid temperature up to +65C. Protection IP 65.

TYPE
MAXI EASYPRESS

VOLT 230 10%

Hz 50/60

CURRENT max 16 A

FITTINGS 11/4 x 11/4

FLOW RATE 12 m3/h

The pressure generated by the pump must be minimum 3 bar and maximum 10 bar. The column of water between the appliance and the highest user must not exceed 15 metres. Liquid temperature up to +65C. Protection IP 65.

TYPE
EASYPRESS VARIO

VOLT 230 10%

Hz 50/60

CURRENT max 16 A

FITTINGS 11/4 x 11/4

FLOW RATE 12 m3/h

Electronic device with possibility of manually regulating the system pressure from 3 to 6.5 bar (complete with pressure gauge). For the system pressure regulated at 3 bar the pressure generated by the pump must be minimum 4.5 bar and maximum 12 bar and the column of water between the appliance and the highest user must not exceed 12 metres; for the system pressure regulated at 6.5 bar the pressure generated by the pump must be minimum 8 bar and maximum12 bar and the column of water between the appliance and the highest user must not exceed 45 metres. Liquid temperature up to +65C. Protection IP 65.

* Electronic devices for starting (when the tap is turned on) and stopping (when the tap is turned off) single-phase pumps. In the event of lack of water, they automatically stop the pump.

223

ACCESSORIES
FLOATS
TYPE 0315/3 0315/5 0315/10
With H07 RN-F cable: With PVC cable:

(APPROVED V.D.E.- I.M.Q.)


CABLE
H07 RN-F or PVC H07 RN-F or PVC H07 RN-F or PVC floats with single function (emptying) and 10 A switch. floats with dual function (emptying and filling) and 10 A switch.

LENGTH
3 metres 5 metres 10 metres

TYPE T 80/3 T 80/5 T 80/10


With H07 RN-F cable: With PVC cable:

CABLE
H07 RN-F or PVC H07 RN-F or PVC H07 RN-F or PVC floats with single function (emptying), with double watertight protection chamber and 10 A switch. floats with dual function (emptying and filling). Double watertight protection chamber and 10 A switch.

LENGTH
3 metres 5 metres 10 metres

TYPE SMALL 3 SMALL 5


With H07 RN-F cable: With PVC cable:

CABLE
H07 RN-F or PVC H07 RN-F or PVC

LENGTH
3 metres 5 metres

floats with single function (emptying), with simple protection and 20 A switch. floats with dual function (emptying and filling). With simple protection and 20 A switch.

FLOATS WITH PLUG SOCKET


TYPE 0315 SI/3 0315 SI/5 0315 SI/10
Floats with emptying function and 10 A switch.

(APPROVED V.D.E.- I.M.Q.)


CABLE
H07 RN-F H07 RN-F H07 RN-F

LENGTH
3 metres 5 metres 10 metres

TYPE T 80 SI/3 T 80 SI/5 T 80 SI/10

CABLE
H07 RN-F H07 RN-F H07 RN-F

LENGTH
3 metres 5 metres 10 metres

Floats with emptying function, with double watertight protection chamber and 10 A switch.

TYPE SMALL SI/3 SMALL SI/5 SMALL SI/10

CABLE
H07 RN-F H07 RN-F H07 RN-F

LENGTH
3 metres 5 metres 10 metres

Floats with emptying function, with simple protection and 20 A switch.

224

ACCESSORIES
FOOT VALVES
TYPE VF 0.5 VF 0.75 VF 1 VF 1.25 VF 1.5 VF 2
Brass foot valves, stainless steel suction filter.

FITTINGS
1/2" 3/4"

1" 11/4" 11/2" 2"

CHECK VALVES
TYPE VR 0.5 VR 0.75 VR 1 VR 1.25 VR 1.5 VR 2
Brass check valves.

FITTINGS
1/2" 3/4"

1" 11/4" 11/2" 2"

BALL CHECK VALVES WITH THREADED FITTINGS


TYPE VR-FT 1.25 VR-FT 1.5 VR-FT 2
Check valves for submersible pumps (sewage and waste water).

FITTINGS

11/4" 11/2" 2"

BALL CHECK VALVES WITH FLANGED FITTINGS


TYPE VR-FF DN 65 VR-FF DN 80
Check valves for submersible pumps (sewage and waste water).

FITTINGS 65 mm 80 mm

225

ACCESSORIES
FILTER HOLDERS WITH PLASTIC HEAD
TYPE MEDIUM MEDIUM JUNIOR JUNIOR SENIOR SENIOR CARTRIDGE HEIGHT THREADED FITTINGS
3/4"

F 0.75 F1 F 0.75 F1 F 0.75 F1

5" 5" 7" 7" 10" 10"

1"
3/4"

1"
3/4"

1"

Maximum working pressure 5 bar (at temp. +20C) Maximum temperature + 45C (at pressure 2 bar). - Filter holder for RL, FA and LA cartridges.

FILTER HOLDERS WITH BRASS HEAD AND AIR VENT


TYPE MEDIUM MEDIUM JUNIOR JUNIOR SENIOR SENIOR CARTRIDGE HEIGHT THREADED FITTINGS
3/4"

K 0.75 K1 K 0.75 K1 K 0.75 / K 1 K 1.5 / K 2

5" 5" 7" 7" 10" 10"

1"
3/4"

1" 1" 11/2" / 2"


3/4" /

Maximum working pressure 10 bar (at temp. +20C) Maximum temperature + 50C (at pressure 3 bar). - Filter holder for RL and FA (K 0.75, K 1) cartridges.

MOBILE FILTER
TYPE DEPURAL 10
CARTRIDGE HEIGHT 10" CARTRIDGE RL 10, FA 10, HA 10

Head in ABS for use with foodstuffs. Cup in AS for use with foodstuffs. It is suitable for connection by means of a hose to any tap in order to supply filtered water, free from impurities.

WRENCHES FOR FILTER HOLDERS


TYPE WRENCH F WRENCH K WRENCH DEPURAL
Suitable for fitting and removing the cartridge from the filter holder.

FILTER HOLDER
F K DEPURAL 10

226

ACCESSORIES
POLYESTER FILTER CARTRIDGES
TYPE RL 5 RL 7 RL 10
FILTRATION 50 50 50 HEIGHT 5" 7" 10"

Cartridge suitable for filter holders type F - K - DEPURAL 10.

POLYPROPYLENE FILTER CARTRIDGES


TYPE FA 5 FA 7 FA 10
FILTRATION 50 50 50 HEIGHT 5" 7" 10"

Cartridge suitable for filter holders type F - K 0.75 - K 1 - DEPURAL 10.

FILTER CARTRIDGE WITH POLYPHOSPHATE CRYSTALS


TYPE HA 10
Cartridge suitable for filter holders type DEPURAL 10.

HEIGHT 10

FILTER CARTRIDGE WITH ACTIVATED CARBON


TYPE LA 10
Cartridge suitable for filter holders type F - K 0.75 - K 1.

HEIGHT 10

227

ACCESSORIES
FLAT PVC HOSE
TYPE TP 1.25 TP 1.50 TP 2.00 TP 2.50 TP 3.00
FITTING LENGTHS 5 - 10 - 20 metres 5 - 10 - 20 metres 5 - 10 - 20 metres 5 - 10 - 20 metres 5 - 10 - 20 metres

11/4" 11/2" 2" 21/2" 3"

Plasticized flat delivery hose, complete with PVC hosetail, resistant to abrasion and to atmospheric agents. Ideal for irrigation even with fertilisers and for draining water in combination with DRAINAGE PUMPS.

SUCTION HOSE
TYPE GARDEN KIT
FITTING LENGTH 7 metres

1"

Hose, complete with foot valve. RECOMMENDED FOR PORTABLE GARDEN PUMPS, BETTY TYPE

MECHANICAL FLOW METER


TYPE MT 1
MAXIMUM FLOW RATE 80 l/min MAXIMUM PRESSURE 3.5 bar FITTINGS

1" x 1"

Mechanical flow meter for private use, suitable for measuring diesel fuel. RECOMMENDED FOR USE WITH TYPE CK PUMPS

DISPENSING NOZZLE WITH HOSE


TYPE NZ 0.75 NZ 1.00
Aluminium dispensing nozzle complete with hose, reinforced with steel spiral, 4 metres long, with threaded fittings. RECOMMENDED FOR USE WITH TYPE CK PUMPS

ELBOW FITTING
3/4"

1"

228

ACCESSORIES
STRAIGHT HOSETAIL FITTINGS
TYPE RP 0.75 RP 1 RP 1.25 RP 1.5 RP 2
Nylon fittings.

HOSETAIL
25 mm 30 mm 35 mm 40 mm 50 mm

THREADED FITTING
3/4"

1" 11/4" 11/2" 2"

CURVED HOSETAIL FITTINGS


TYPE RPG 0.75 RPG 1 RPG 1.25 RPG 1.5 RPG 2
Nylon fittings.

HOSETAIL
25 mm 30 mm 35 mm 40 mm 50 mm

THREADED FITTING
3/4"

1" 11/4" 11/2" 2"

TEFLON TAPE FOR HYDRAULIC JOINS


TYPE TFN 1 TFN 2
LENGTH 12 metres 50 metres

PAINT AEROSOL
TYPE SPRAY 1
COLOUR pedrollo blue CAPACITY 400 ml

229

ACCESSORIES
CAPACITORS FOR SURFACE PUMPS
TYPE 06 F 10 F 12 F 14 F 16 F 16 F 20 F 20 F 25 F 25 F 30 F 30 F 31 F 40 F 45 F 50 F 55 F 60 F 70 F 80 F 80 F
CAPACITY 6.3 F 10 F 12.5 F 14 F 16 F 16 F 20 F 20 F 25 F 25 F 30 F 30 F 31.5 F 40 F 45 F 50 F 55 F 60 F 70 F 80 F 80 F VOLTAGE 450 V 450 V 450 V 450 V 450 V 250 V 450 V 250 V 450 V 250 V 450 V 250 V 450 V 450 V 450 V 450 V 450 V 450 V 450 V 450 V 250 V FREQUENCY 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz

type F= FASTON

- Capacitors with CE marking and VDE-IMQ approval

CAPACITORS FOR SUBMERSIBLE PUMPS TYPE 08 C 10 C 12 C 14 C 16 C 20 C 25 C 30 C 30 C 31 C 35 C 40 C 45 C 50 C 60 C 75 C 80 C


CAPACITY 8 F 10 F 12.5 F 14 F 16 F 20 F 25 F 30 F 30 F 31.5 F 35 F 40 F 45 F 50 F 60 F 75 F 80 F VOLTAGE 450 V 450 V 450 V 450 V 450 V 450 V 450 V 450 V 250 V 450 V 450 V 450 V 450 V 450 V 250 V 450 V 250 V FREQUENCY 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz

type C= OUTGOING CABLES

- Capacitors with CE marking and VDE-IMQ approval

230

ACCESSORIES
BEARINGS
TYPE 6201 ZZ 6201 ZZ 6202 ZZ 6203 6203 ZZ 6203 ZZ 6203 2RS 6204 ZZ 6204 ZZ 6205 ZZ 6206 ZZ 6304 ZZ 6304 ZZ 6304 2RS 6306 ZZ 6307 ZZ 6308 ZZ 6310 ZZ 7203 B 7303 B
INTERNAL PLAY Normal C3 (increased) Normal Normal Normal C3 (increased) Normal Normal C3 (increased) Normal C3 (increased) Normal C3 (increased) Normal C3 (increased) C3 (increased) C3 (increased) C3 (increased) Normal Normal DIMENSIONS 12 x 32 x 10 mm 12 x 32 x 10 mm 15 x 35 x 11 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 20 x 47 x 14 mm 20 x 47 x 14 mm 25 x 52 x 15 mm 30 x 62 x 16 mm 20 x 52 x 15 mm 20 x 52 x 15 mm 20 x 52 x 15 mm 30 x 72 x 19 mm 35 x 80 x 21 mm 40 x 90 x 23 mm 40 x 90 x 23 mm 17 x 40 x 12 mm 17 x 47 x 14 mm

SEALS FOR SURFACE PUMPS


TYPE
Fixed ring

MATERIALS
Rotating ring Grafite Grafite Grafite Grafite Grafite Graphite Grafite Grafite Grafite Grafite Grafite Elastomer NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR NBR Spring AISI 304 AISI 304 AISI 304 AISI 304 AISI 304 AISI 316 AISI 316 AISI 316 AISI 316 AISI 316 AISI 316 AISI 316 Ceramica Ceramica Ceramica Ceramica Ceramica Ceramic Ceramica Ceramica Ceramica Ceramica Ceramica

SHAFT 12 mm 13 mm 14 mm 12 mm 14 mm 18 mm 18 mm 20 mm 24 mm 32 mm 38 mm

AR

PNL

AR 12 AR 13 AR 14 PNL 12 FN 14 FN 18 FN 18 NU (Dimensions DIN 24960) FN 20 FN 24 FN 32 NU (Dimensions DIN 24960) FN 38

FN

RN

SEALS FOR SUBMERSIBLE PUMPS


TYPE
Fixed ring

MATERIALS
Rotating ring Graphite Carburundum Graphite Carburundum AISI 431 Graphite Elastomer NBR NBR NBR NBR NBR NBR NBR Spring AISI 304 AISI 304 AISI 304 AISI 316 AISI 316 AISI 316 AISI 431 AISI 316 AISI 316 AISI 316 Ceramica Ceramic Ceramica Widia Graphite Ceramic

SHAFT 12 mm 13 mm 16 mm 20 mm 17 mm 14 mm 14 mm

MG

FN DV

AR 12/R AR 13/R PNL 16 FN 20 DV RN 15/17 MG1S1/14 MG1S2/14

Carburundum Carburundum

Special mechanical seals on request.

231

ACCESSORIES
CABLE FOR LEVEL PROBES
TYPE CSL
SECTION 1.5 mm
2

WEIGHT PER METRE 0.019 kg

CABLES FOR SUBMERSIBLE PUMPS


TYPE 4x1 4 x 1.5 4 x 2.5 4x4 4x6 4 x 10 4 x 16
WEIGHT PER METRE mm2 H07 RN-F mm2 H07 RN-F mm2 H07 RN-F mm2 H07 RN-F mm2 H07 RN-F mm2 H07 RN-F mm2 H07 RN-F 0,165 kg 0,205 kg 0,290 kg 0,420 kg 0,505 kg 1,030 kg 2,050 kg

3M RESIN JOINT KIT FOR ELECTRIC CABLES


TYPE RPS 1 RPS 2 RPS 3 RPS 4 RPS 5 RPS 6
No. OF CORES 4 4 4 4 4 4 CABLE SECTION 1 2.5 mm2 1 10 mm2 4 16 mm2 14 25 mm2 16 35 mm2 35 95 mm2 EXT. JUNCTION 32 mm 42 mm 48 mm 60 mm 65 mm 80 mm

3M HEAT-SHRINK JOINT KIT FOR ELECTRIC CABLES


TYPE GPS 1 GPS 2 GPS 3 GPS 4 GPS 5 GPS 6
No. OF CORES 4 4 4 4 4 4 CABLE SECTION 1 2.5 mm2 4 6 mm2 10 mm2 16 mm2 25 mm2 35 mm2

232

ACCESSORIES
CABLES WITH PLUG FOR SINGLE-PHASE SURFACE PUMPS
TYPE H05 VV-F (PVC) H07 RN-F (NEOPRENE)
CABLE SECTION 3 x 0.75 mm2 3 x 1 mm
2

LENGTH 150 cm 150 cm

PLUG Schuko Schuko

FANS
TYPE 14VN05 14VN06 14VN07 14VN08 14VN08L 14VN09 14VN10 14VN1062 14VN13
DIMENSIONS 85 x 18 mm 104 x 21 mm 125 x 24 mm 138 x 27 mm 138 x 27 mm 162 x 32 mm 176 x 38 mm 155 x 37 mm 165 x 45 mm SHAFT DIAMETER 12 mm 12 mm 14.5 mm 20 mm 20 mm 24 mm 28 mm 28 mm 36 mm

233

ELECTRIC PANEL
FOR 4 SINGLE-PHASE BOREHOLE PUMPS
TYPE QEM 033 QEM 050 QEM 075 QEM 100 QEM 150 QEM 200 QEM 300
MOTOR POWER kW HP 0.25 0.37 0.55 0.75 1.1 1.5 2.2 0.33 0.50 0.75 1 1.5 2 3 CAPACITOR F 12.5 16 20 30 40 50 75 RATED CURRENT 3.5 4.5 6 7 11 13 18 A A A A A A A

- Single-phase 220 230V 50 Hz The control panel is supplied in a flame retardant plastic box; it protects the pump against overloads and short circuits and may be connected to a float or a pressure switch. COMPONENTS: Isolating switch with fuse Start-stop switch Terminals for connecting the pump and a float or a pressure switch Thermal protection with manual reset Green pump running lamp For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.

FOR 4 AND 6 THREE-PHASE BOREHOLE PUMPS


TYPE QET QET QET QET QET QET QET QET QET QET QET QET QET QET QET QET QET 050 075 100 150 200 300 400 550 750 1000 1250 1500 1750 2000 2500 3000 4000
MOTOR POWER kW HP 0.37 0.50 0.55 0.75 0.75 1 1.1 1.5 1.5 2 2.2 3 3 4 4 5.5 5.5 7.5 7.5 10 9.2 12.5 11 15 13 17.5 15 20 18.5 25
22 30

RATED CURRENT 1.7 A 2 A 2.5 A 3.9 A 4.8 A 7 A 9 A 11.5 A 15.5 A 21.5 A 23.5 A 27.5 A 31.5 A 36 A 45 A
54 A

30

40

68 A

- Three-phase 380 415V 50 Hz The control panel is supplied in a flame retardant plastic box; it protects the pump against overloads and short circuits and has a selector for manual or automatic operation (with float, pressure switch, etc.). COMPONENTS: Isolating switch with fuse Selector for manual or automatic operation Three-pole contactor Adjustable three-pole thermal relay with manual reset Terminals for connecting the pump and a float or a pressure switch Green pump running lamp. For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.

234

ELECTRIC PANEL
FOR 4 SINGLE-PHASE PUMPS WITH LEVEL PROBES
TYPE QSM QSM QSM QSM QSM QSM QSM 033 050 075 100 150 200 300
MOTOR CURRENT kW HP 0.25 0.37 0.55 0.75 1.1 1.5 2.2 0.33 0.50 0.75 1 1.5 2 3 CAPACITOR F 12.5 16 20 30 40 50 75 RATED CURRENT 3.5 4.5 6 7 11 13 A A A A A A

17.5 A

- Single-phase 220 230V 50 Hz The control panel is supplied in a flame retardant plastic box; it protects the pump against overloads and short circuits. It has a selector for manual or automatic operation (with float, pressure swich, etc.) and may be connected to level probes that protect the pump against dry operation. COMPONENTS: Isolating switch with fuse Selector for manual or automatic operation Three-pole contactor Thermal protection with manual reset Capacitor Terminals for connecting the pump, a float or a pressure switch, and the level probes Green pump running lamp Red cut-out warning lamp Level probes (the CSL type cables for connection of the probes are excluded) For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.

Level probes

FOR 4 AND 6 THREE-PHASE PUMPS WITH LEVEL PROBES


TYPE QST QST QST QST QST QST QST QST QST QST QST QST QST QST QST QST 050 075 100 150 200 300 400 550 750 1000 1250 1500 1750 2000 2500 3000
MOTOR POWER kW HP 0.37 0.50 0.55 0.75 0.75 1 1.1 1.5 1.5 2 2.2 3 3 4 4 5.5 5.5 7.5 7.5 10 9.2 12.5 11 15 13 17.5 15 20 18.5 25 22 30 RATED CURRENT 1.7 A 2 A 2.5 A 3.9 A 4.8 A 7 A 9 A 11.5 A 15.5 A 21.5 A 23.5 A 27.5 A 31.5 A 36 A 45 A 54 A

Sonde Level probes di livello

- Three-phase 380 415V 50 Hz The control panel is supplied in a flame retardant plastic box; it protects the pump against overloads and short circuits. It has a selector for manual or automatic operation (with float, pressure swich, etc.) and may be connected to level probes that protect the pump against dry operation. COMPONENTS: Isolating switch with fuse Selector for manual or automatic operation Three-pole connector Adjustable three-pole thermal relay with manual reset Terminals for connecting the pump, a float or a pressure switch and the level probes Green pump running lamp Red cut-out warning lamp Level probes (the CSL type cables for connection of the probes are excluded) For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.

235

ELECTRIC PANEL
CURRENT SENSING - FOR 4 AND 6 BOREHOLE PUMPS
TYPE EVOLUTION MONO EVOLUTION TRI/1 EVOLUTION TRI/2
ADJUSTABLE POWER kW HP
from 0.37 to 2.2 from 0.5 to 3 from 0.55 to 7.5 from 0.75 to 10 from 7.5 to 10 from 10 to 15

VOLTAGE single-phase three-phase three-phase

RATED CURRENT
from 2 to 16 A from 2 to 15 A from 16 to 24 A

- Single-phase 220 230V 50 Hz - Three-phase 380 415V 50 Hz Contained within a flame retardant enclosure, the Evolution offers protection against overloads and short circuits, and monitors the power factor (cos) to protect the pump against dry running without the need for level probes. There is also a connection provided for an external float or pressure switch. COMPONENTS:

Isolating switch with fuse Start-stop switch with door interlock Trimmer controls for user adjustment of the electronic protectors Three-pole contactor (three-phase versions only) Terminals for connecting the pump Terminals for connecting a float or pressure switch External display with warning led.
N.B. For single-phase models, the capacitor is not included and should be selected to suit the pump. For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.

FOR SINGLE -PHASE DRAINAGE PUMPS


TYPE QES 300 MONO
MOTOR POWER kW HP 2.2 3 CAPACITOR F 60 RATED CURRENT 16 A

- Single-phase 220 230V 50 Hz Contained within a flame retardant IP55 enclosure, the panel protects the pump against overloads and short circuits. It also has provision for the connection of the thermal cut-outs provided in the winding of drainage pump models VXCm30, PVXCm30, MCm30, PMCm30. COMPONENTS: Isolating switch with fuse Start-stop switch Three-pole contactor Adjustable three-pole thermal relay with manual reset Capacitor Terminals for connecting the pump Terminals for connecting pump thermal protection circuits Green pump running lamp Red cut-out warning lamp. COMPONENTS ON REQUEST:

Auxiliary contacts for level alarm Red high level warning lamp Output (230V) for external warning lamp/
sounder. For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.

FOR THREE-PHASE DRAINAGE PUMPS


TYPE QES 150 QES 200 QES 300
MOTOR POWER kW HP 1.1 1.5 2.2 1.5 2 3 RATED CURRENT 4.2 A 5.2 A 6.5 A

- Three-phase 380 415V 50 Hz Contained within a flame retardant IP55 enclosure, the panel protects the pump against overloads and short circuits. It has a selector for manual or automatic (floatswitch) operation and provision for the connection of the thermal protection circuit provided in pump models VXC, PVXC, MC, PMC. COMPONENTS: Isolating switch with fuses Selector for manual or automatic operation Three-pole contactor Adjustable three-pole thermal relay with manual reset Terminals for connecting the pump Terminals for connecting the pump thermal protection circuit (VXC, PVXC, MC, PMC) Terminals for connecting the float Green pump running lamp For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.

236

CABLE SIZES FOR SUBMERSIBLE MOTORS DIMENSIONAMENTO DEI CAVI PER MOTORI SOMMERSI
SINGLE-PHASE 230 V - 50 Hz
MOTOR POWER
kW HP

cable section in mm2

4x1
0,33 0,50 0,75 1 1,5 2 3 70 60 45 35 25

4 x 1.5
105 90 70 50 35 30

4 x 2.5
170 140 110 85 60 45 30

4x4

4x6

4 x 10

4 x 16

maximum cable length in metres

0,25 0,37 0,55 0,75 1,1 1,5 2,2

180 140 95 75 50

210 145 115 75

240 190 125

305 200

THREE-PHASE 230 V - 50 Hz
MOTOR POWER
kW HP

cable section in mm2

4x1
100 83 65 48

4 x 1.5
152 126 99 72 53

4 x 2.5
255 210 165 120 88 60 47

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

4 x 70

maximum cable length in metres 338 265 192 142 97 73 55

0,37 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 9,2 11 13 15 18,5 22 30

0,50 0,75 1 1,5 2 3 4 5,5 7,5 10 12,5 15 17,5 20 25 30 40

405 292 215 147 110 83 60 45

485 360 245 183 138 100 73 64 54

392 295 220 160 114 100 87 75 65

510 380 275 195 157 135 117 102 82 69

385 275 220 190 164 144 114 95 70

395 315 270 236 205 162 137 102

378 330 287 225 190 142

THREE-PHASE 400 V - 50 Hz
MOTOR POWER
kW HP

cable section in mm2

4x1
300 250 195 145 105 70 55 40

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

4 x 70

maximum cable length in metres 380 295 215 160 110 85 60 45 35

0,37 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 9,2 11 13 15 18,5 22 30

0,50 0,75 1 1,5 2 3 4 5,5 7,5 10 12,5 15 17,5 20 25 30 40

360 265 180 140 105 75 55 47 40

425 290 220 165 120 95 75 65 60 50

440 330 250 180 135 115 95 85 75 58 49 36

415 300 220 190 160 140 125 100 85 63

480 340 300 260 225 195 155 130 96

585 470 405 350 305 245 205 152

490 430 340 285 210

485 410 305

570 425

Voltage drop 3% - Maximum environment temperature + 30 C

237

DIAGRAMDIA DELLE PERDITE DI CARICO DIAGRAM OF LOAD LOSSES


per tubazioni diritte di 15-250 mm di diametro and flow rate from 8 a 8330 l/min. For straight pipes 15-250 mm internal diameterinterno e portate da 8 to 8330 l/min.

100

50

30 20

10

Losses in metres for each 100 metres of pipe

4.6

3 2

0.5

0.3 0.2

0.1

0.05 0.03 0.02

0.01 8 0.5 16 1 30 2 50 3 83 5 160 10 330 20 500 30 830 50 1660 100 3330 5000 200 300 8330 Q l/min 500 Q m3/h

Flow rate Q

The data in the table refer to cold water and to liquids with the same kinematic viscosity, for new cast iron pipes. The losses (hv) shown in the table must be multiplied by: 0.8 for new steel pipes, 1.25 for old and slightly rusty iron pipes, and 1.7 for heavily corroded pipes - for which the reduction in actual bore should also be considered. EXAMPLE: Flow rate data Q = 500 l/min, new steel pipe 80 mm, pipe length 50 m. Find the flow rate on the horizontal axis and continue vertically until you meet the line DN 80 mm. The load losses can then be read on the vertical axis. hv = 4.6 m every 100 m of pipe. hv1 = 4.6 x 0.8 = 3.68 m/100 (steel pipe). To consider the real length of the pipe: hv2 = 3.68 x 50:100 = 1.84 m (for 50 m of pipe). The speed of flow is determined considering the point of intersection which is between the oblique lines with value 1.5-2 m/sec. So in the case considered that gives: C = 1.7 metres/sec.

238

Ve lW oc ate i rde l in spa m/ leed s cqu

CONVERSIONE UNITS UNIT DI MISURA CONVERSION OF DELLE OF MEASUREMENT

LENGTH
millimetre mm 1 10 1000 25.4 304.8 914.4 centimetre cm 0.1 1 100 2.54 30.48 91.44 metre m 0.001 0.01 1 0.0254 0.3048 0.9144 inch in 0.0394 0.3937 39.3701 1 12 36 foot ft 0.0033 0.0328 3.2808 0.0833 1 3 yard yd 0.0011 0.0109 1.0936 0.0278 0.3333 1

1 kilometre = 1000 metres = 0.62137 miles - 1 mile = 1609.34 metres = 1.60934 kilometres

VOLUME
cubic metre m3 1 0.001 1 x 10-6 0.00455 0.00378 0.0283 litre l 1000 1 0.001 4.546 3.785 28.317 millilitre ml 1 x 10 1000 1 4546 3785 28.317
6

imperial gallon Imp. gal 220 0.22 2.2 x 10-4 1 0.8327 6.2288

US gallon US gal 264.2 0.2642 2.642 x 10-4 1.201 1 7.4805

cubic foot ft3 35.3147 0.0353 3.53 x 10-5 0.1605 0.1337 1

WEIGHT
kilogram kg 1 0.454 50.802 1000 1016 907.2 pound lb 2.205 1 112 2204.6 2240 2000 hundredweight cwt 0.0197 0.0089 1 19.684 20 17.857 ton t 0.001 4.54 x 10-4 0.0508 1 1.0161 0.9072 long ton tn 9.84 x 10-4 4.46 x 10-4 0.05 0.9842 1 0.8929 short ton sh. tn 0.0011 5.0 x 10-4 0.056 1.1023 1.102 1

VOLUMETRIC FLOW RATE


litres second litres minute cubic metres hour cubic feet hour cubic feet minute Imp. gal. minute US gal. minute US barrel day (oil) l/s 1 0.017 0.278 0.008 0.472 0.076 0.063 0.002 l/min 60 1 16.667 0.472 28.317 4.546 3.785 0.110 m /h 3.6 0.06 1 0.0283 1.6990 0.2728 0.2271 0.0066
3

ft /h 127.133 2.1189 35.3147 1 60 9.6326 8.0209 0.2339

ft /min 2.1189 0.0353 0.5886 0.0167 1 0.1605 0.1337 0.0039

Imp. gal/min 13.2 0.22 3.666 0.104 6.229 1 0.833 0.024

US gal/min 15.85 0.264 4.403 0.125 7.480 1.201 1 0.029

US barrel/g 543.439 9.057 150.955 4.275 256.475 41.175 34.286 1

PRESSURE AND HEAD


Newton square metre N/m2 (Pa) 1 1000 100000 98067 6895 2984 9789 133.3 3386 kPa 0.001 1 100 98.07 6.895 2.984 9.789 0.133 3.386 bar 1 x 10 0.01 1 0.981 0.069 0.03 0.098 0.0013 0.0338
5

kiloPascal

bar

kilogram force square centimetre kgf/cm2 1.02 x 105 1.02 x 105 1.02 1 0.0703 0.0305 0.1 0.0014 0.0345

pound force square inch psi 1.45 x 10-4 0.145 14.5 14.22 1 0.433 1.42 0.019 0.491

foot of water

metre of water

millimetre mercury

inch mercury

ft H20 3.35 x 10-4 0.335 33.52 32.81 2.31 1 3.28 0.045 1.133

m H20 1.02 x 10-4 0.102 10.2 10 0.703 0.305 1 0.014 0.345

mm Hg 0.0075 7.5 750.1 735.6 51.72 22.42 73.42 1 25.4

In Hg 2.95 x 10-4 0.295 29.53 28.96 2.036 0.882 2.891 0.039 1