Beruflich Dokumente
Kultur Dokumente
Welcome, Mastervolt
Actuant Corporation, the parent company of Marinco, acquired the Mastervolt brand in December 2010 to complement its line of the marine and harsh-duty products. Since Marinco and Mastervolt have branded products and services that support the marine and mobile markets, these elements have been folded into a single entity that provide a number of benefits: A broader product selection, A single solution for virtually every marine electrical need, Enhanced customer service Global distribution
Table of Contents
Connect
Inlets Cordsets & Adapters Devices & Accessories International DC Connections
4
6 17 23 28 33
Generate
GPX Hybrid Generator Alternators & Regulators
38
40 43
Convert
Battery Chargers Sine Wave Inverters Inverter / Charger Combinations DCDC Converters Shore Transformers
48
50 62 68 74 80
Store
Batteries
84
86
Manage
Battery Switches Circuit Protection & Panels Distribution Components Transfer Switches MasterBus CZone Monitoring Wire & Wire Management
92
94 113 145 150 154 164 181 188
Propel
Electric Propulsion
224
226
Accessories
Wiper Systems Horns Lighting Ventilation
232
234 248 257 268
Index
274
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect Marinco Shore Power Systems ______________________ 6 Marinco Power Inlets _______________________________ 8 30 Amp/125V Inlets ________________________________10 50 Amp/125V Inlets ________________________________11 50 Amp 125V/250V Inlets ___________________________12 ELCI Inlets & Ignition Protected Breakers _____________13 Cable TV/Internet __________________________________15 Cordsets _________________________________________17 Shore Power Adapters _____________________________18 30 Amp Devices ___________________________________23 50 Amp Devices ___________________________________24 15 & 20 Amp Devices ______________________________25 20 Amp Devices & Accessories _____________________26 Boxes / Covers / Replacement Parts _________________27 International Shore Power ___________________________28 100 Amp Devices __________________________________32 DC Connections ___________________________________33 5
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
l Dockside Products
Marine Receptacles
Corrosion resistant reinforced nylon construction
l Cordsets
Male Plugs
Superior strain-relief system. Dust seal keeps contaminants out of terminals
Weatherproof Covers
Yellow LEXAN polycarbonate with lift lid, for use with Marinco receptacles
Weatherproof Covers
Heavy duty vinyl construction, use with male plugs for superior seal
Marine Grade cable, watertight molded plug and connector, line-up ridge for easy blade alignment
30A
305CRR
7420CR
305CRPN
102N
50SPP
50A
6370CR
7788CR
6361CRN
7717N
6153SPP
50A
6369CR
7788CR
6365CRN
7717N
6152SPP
Cable TV / Internet
TV97
PH6623
TVHD
Marinco Color Coding System products for products for products for products for products for
15 AMP
20 AMP
30 AMP
50 AMP 125V
50 AMP 125V/250V
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
l Boatside Products
Weatherproof Covers
Heavy duty vinyl construction, use with female connector for superior seal
Connect | Inlets
Female Connectors
Styled to complement any boat, Marinco power inlets are simple to install and feature a protective rear safety enclosure that provides safe, reliable strain relief
Power Inlets
103RN
305CRCN
303SSEL-B
301EL-B
304EL-B
7715CRN
6360CRN
6371EL-B
6351EL-B
6343EL-B
7715CRN
6364CRN
6373EL-B
6353EL-B
6344EL-B
PH6624
TV6592
TV6574
TV6444
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Inlets
Marinco Power Inlets are the industry standard. Offered in three styles, they all feature robust construction and corrosion-resistant materials for long life in the harsh marine environment. Each has technical features that make them easy to install and a pleasure to use for the marine professional or the casual recreational boater.
Stainless Steel Marinco stainless steel inlets are solid cast marine grade 316 stainless steel and include a heavy duty cap strap for strength and durability.
Contoured Marinco contoured inlets feature UV stabilized glass-filled polyester construction for long-lasting strength.
Standard Marinco standard inlets feature UV stabilized glass-filled polyester construction for long-lasting strength.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect | Inlets
1 Easy LockMarincos exclusive Easy Lock System has been designed to make hook-up quick and easy. Just connect the cordset (with an Easy Lock locking ring installed) to the inlet and turn the locking ring less than a quarter turn. The tabs on the locking ring lock into the inlet for a positive watertight hook-up while eliminating any chance of cross threading. The locking ring features lock locators positioned at 180 to improve finger grip during attachment. Easy Lock inlets have a threaded boss that will accept threaded cordsets as well. The Easy Lock system is a standard feature on some Marinco 30 amp and 50 amp inlets and cordsets.
2 The covers on all Marinco inlets are designed to stay hinged open when the cover is lifted up. This allows the boater to connect their shore power cord while the cover remains open and out of the way. A soft touch unlocks it for closing. 3 Blades are nickel plated brass for maximum corrosion resistance. 4 Interior hardware is marine-grade stainless steel.
Rear Enclosure Made of flame-resistant UL94V plastic. All rear enclosures are glass-filled polyester for strength. Integral strain relief complies with ABYC requirements. Multiple positions allow for maximum installation flexibility.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
NEMA G L5-30R
Meets or Exceeds
Standards
30 AMP
125V
30 AMP
125V
30 AMP
125V
trim
30 AMP
125V
30 AMP
125V
30 AMP
125V
Power Inlet
NOTE: Di erent AMPS icons Stainless steel on di erent layers
Power Inlet
trim white white gray cap & bezel
NOTE: Di erent AMPS icons ABYC shore on di erent layers on cap
steel trim
Item # 301EL-B.w/L
30 AMP
125V
30 AMP
125V
30 AMP
125V
Power Inlet
Stainless steel NOTE: Di erent AMPS icons on di erent layers trim Hole at rear enclosure
Breaker Inlet
NOTE: Di erent AMPS icons Includes cap & on di erent layers breaker plate
bezel and
Item # 301EL-B.FR
10
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
NEMA SS-1
G 50A
Meets or Exceeds
Connect | Inlets
125V Locking
Standards
50 AMP
125V
50 AMP
125V
50 AMP
125V
50 AMP
125V
50 AMP
125V
Power Inlet
Stainless steel trim Without rear safety enclosure Item # 6351EL
Power Inlet
With out stainless steel trim ABYC shore power warning label on cap Item # 6351EL-B
There are two categories of 50A devices: 50A 125V (50A 3-wire) and 50A 125/250V (50A 4-wire). The 4-wire devices have two hot legs, each carrying 50A 125V. These two categories are not interchangeable. A 3-wire plug must never be altered to insert into a 4-wire connector or receptacle.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
11
NEMA X SS-2
W G
Y 50A
Meets or Exceeds
125/250V Locking
Standards
125/250V
50 AMP
125/250V
50 AMP
125/250V
50 AMP
125/250V
50 AMP
125/250V
50 AMP
125/250V
50 AMP
Power Inlet
Stainless steel trim Item # 6353EL-B OEM # 6353EL-B.OEM Cap & Bezel Item # 6353ELCB
125/250V
50 AMP
125/250V
50 AMP
125/250V
50 AMP
Power Inlet
Stainless steel trim Black OEM # 6353EL-B.BLACK.OEM
Power Inlet
Stainless steel trim Gray Item # 6353EL-B.GRAY
Power Inlet
Stainless steel trim Without rear safety enclosure Item # 6353EL
There are two categories of 50A devices: 50A 125V (50A 3-wire) and 50A 125/250V (50A 4-wire). The 4-wire devices have two hot legs, each carrying 50A 125V. These two categories are not interchangeable. A 3-wire plug must never be altered to insert into a 4-wire connector or receptacle.
12
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect | Inlets
ELCI inlets
Marinco's solution to the ABYC E-11 requirement is based on our industry-standard marine inlets. We have taken the best available technology and built it into our inlets to provide boat builders and owners with the safest, best looking and most durable solution possible. We provide two modules in addition to the standard inlet. One houses the ELCI Marine Sensing Module, the other the breaker. Unlike competing systems, our ELCI Marine sensing module has a 3/4" diameter coil that accepts up to three 6 gauge conductors. This sensing module, which also incorporates a test circuit, is compatible with 30A 125V, 50A 125V and 50A 125V/250V systems. There is a different breaker for 30A and 50 systems.
LINE
H N
WHITE BLACK YELLOW (SHUNT)
GROUNDING wIRE
L1 (BLACK) L2 N
BLACK YELLOW (SHUNT)
PANEL BOARD
WHITE
GROUNDING wIRE
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
13
OEM # 303SSBKRPL.OEM
OEM # 304BKRPL.OEM
OEM # 301BKRPL.OEM
14
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect | Inlets
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
Telephone Adapter
Use to hook up telephone to cordset PH6599. No inlet installation required. Item # PH6600
Telephone Adapter
Use to hook up a locking type inlet to a modular telephone connection Item # PH6601
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
15
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
Telephone Cordset
3 conductor #16SJTO vinyl cord provides portable telephone connection for RV's and pleasure boats. 50' Item # PH6599 Item # PH6599-25 25'
CABLE
INTERNET
TV
USB Port
6 ft USB extension cable with weatherproof cap Item # USBA6 OEM # USBA6.OEM
CABLE
INTERNET
TV
CABLE
INTERNET
TV
CABLE
INTERNET
TV
Cable TV Outlet
Spring-loaded lift cover Weatherproof closure Fits FS & FD boxes Item # TV97 OEM # TV97.OEM
Telephone Outlet
Spring-loaded lift cover Weatherproof closure Fits FS & FD boxes Item # PH6597
16
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect: Cordsets
All Marinco cordsets are made of the highest quality, marine-grade construction with features you wont find on other power cords. 1 Watertight molded plug and connector for safety and durability 2 Heavy duty, super flexible marine-grade cable (30 amp 10 gauge, 50 amp 6 gauge) 3 All models include a standard threaded ring for hook-up to ordinary threaded inlets 4 Corrosion resistant, nickel plated contacts 5 Power Indicator Light: Boatside connector features a molded-in LED light. When it glows red, you know you have power to the boat. 6 Contour Grip with Thumbprint Locator: Both plug and connector ends are molded to fit the contour of your hand. When the thumbprint is in the 12 oclock position, the blades line up for easy connection. 7 Marincos Easy Lock system: Quickly locks the cord set to the inlet in just 1/8 of a turn. The exclusive locking tabs engage slots built into all Marinco inlets.
50SPP 1 4 3
Length Color
NEMA L5-30R
G W
Pkg
Item #
12 ft 25 ft 25 ft 35 ft 50 ft 50 ft
yellow sleeve pack 199116 yellow sleeve pack 199117 white sleeve pack yellow sleeve pack yellow sleeve pack 199119 white sleeve pack 199120 6153SPP-25 6153SPP 6153SPPw
7 6
Contoured Grip
NEMA SS-1
W G
75 ft 25 ft 50 ft 50 ft 12 ft 25 ft 25 ft 50 ft 50 ft 55 ft 75 ft
Cordsets (4-wire)
yellow box yellow box white white white white box box box box yellow box
Easy Lock
6153SPPw
6152SPP
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
17
The Marinco Shore Power Adapters give you more power hook-up flexibility and resolve a variety of dockside power center / boat side inlet power incompatibility problems.
Types of Adapters
Straight Adapters are high-quality, one-piece adapters similar in usage to Pigtail Adapters. However, they do not have sealing collars and are not recommended for use in wet locations. Use only in an enclosed, dry location, such as powering your boat from a 15A power receptacle inside your house.
Pigtail Adapters allow you to connect from one dockside receptacle (or other power source receptacle) to one boatside inlet or equipment of dissimilar power configuration. These adapters are fully molded and equipped with Marincos unique sealing collar (where indicated) and covers for use in wet locations.
Y Adapters let you split one dock side receptacle between two boat inlets of similar or dissimilar power configurations. Y adapters are fully molded and equipped with Marincos unique sealing collar and covers (where indicated) for use in wet locations. The Reverse Y Adapter (Item # RY504-2-30) The reverse Y provides 50A 125/250V power when only two 30A 125V receptacles are available.
Choosing the Correct Adapter 1 Boat Side Identify your boat's Inlet Electrical System
The voltage and amperage should be printed on the outside cover of your existing boat inlet(s) Check the blade orientation of the various inlets pictured and compare to your boat inlet(s)
Y G
50A 125V
The voltage and amperage should be printed inside the boat Inlet(s) next to the blades
30A 125V
50A 125/250V
Pay special attention to the differences in the 50A 125V and the 50A 125/250V. The blades look similar, but they are different. The plugs and receptacles for these systems are NOT interchangeable!!
18
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
when using any adapter remember: 1. Outlet and equipment must be of the same voltage rating. 2. Total amperage drawn should not exceed amperage rating of the lowest rated component of the adapter. 3. Polarity and grounding must be maintained both dock side and boat side. 4. A single cordset should only draw power from a single receptacle (exception is the Reverse Y Adapter).
Straight Adapters
Not recommended for use in wet locations. Item #
BOAT SIDE
FEMALE CONNECTOR Attaches to boat inlet or cordset
G
DOCK SIDE
MALE PLUG Attaches to dockside receptacle or cordset
80A
W G
81A
83A
NEMA G L5-30R
84A
NEMA G L5-30R
W G
Pigtail Adapters
These adapters are equipped with covers and sealing collars (where indicated), and are for use in wet locations. Item #
BOAT SIDE
FEMALE CONNECTOR Attaches to boat inlet or cordset
DOCK SIDE
MALE PLUG Attaches to dockside receptacle or cordset
104SPP
104SPP-25.OEM 104SPP-50.OEM
NEMA G L5-30R
105SPP
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
19
Pigtail Adapters
Item #
BOAT SIDE
FEMALE CONNECTOR Attaches to boat inlet or cordset
DOCK SIDE
MALE PLUG Attaches to dockside receptacle or cordset
110A
NEMA G L5-30R
111A
W G
115A
117A
X G
W G
118A
X G
121A
NEMA G L5-30R
Y G
123A
Y G
20
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Y Adapters
These adapters are equipped with covers and sealing collars (where indicated), and are for use in wet locations. Item #
BOAT SIDE
FEMALE CONNECTOR Attaches to boat inlet or cordset
W W
DOCK SIDE
MALE PLUG Attaches to dockside receptacle or cordset
152AY
NEMA G L5-30R
153AY
NEMA G L5-30R
230A 125V
Y
X G
System
Collar
154AY
Y G
157AY
NEMA G L5-30R
W G
162AY
165AY
X G
Y X G
Y G
Reverse Y Adapter
Item #
BOAT SIDE
FEMALE CONNECTOR Attaches to boat inlet or cordset
W
DOCK SIDE
MALE PLUG Attaches to dockside receptacle or cordset
W G G
RY504-2-30
X G
The Reverse Y Adapter has two male plugs with special power isolation circuitry for added safety. When one plug is connected to a receptacle, the circuitry isolates the second plug. The reverse Y provides 50A 125/250V power when only two 30A 125V receptacles are available. Note: Reverse Y will NOT work with 50A, 125V, 3-wire inlets. Power is provided in both circuits to the 4-wire inlet, but the dock side receptacles limit the current in each circuit to 30A. The two 30A 125V receptacles must be supplied from a single power source providing from 208V to 250V between them for proper operation.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
21
BOAT SIDE
FEMALE CONNECTOR Attaches to boat inlet or cordset
W
DOCK SIDE
MALE PLUG Attaches to dockside receptacle or cordset
W G
1RPC
(30 amp)
NEMA G L5-30R
30A 125V
1RPC50
(50 amp)
X G
Y G
BOAT SIDE
FEMALE CONNECTOR Attaches to boat inlet or cordset
W
DOCK SIDE
MALE PLUG Attaches to dockside receptacle or cordset
W G
G30
NEMA G L5-30R
30A 125V
The world's only shore power corrosion detector with reverse polarity indicator. GalvanAlert easily attaches to your existing 30A shore power inlet and cordset to constantly monitor unsafe corrosion activity or a reverse polarity condition. Can save you thousands of dollars in potential corrosive damage to your boat Detects reverse polarity that can create a shock or fire hazard
How does GalvanAlert work? GalvanAlert incorporates sensor-based technology that monitors unsafe galvanic or stray current corrosion flowing through the green ground wire of your shore power system. why GalvanAlert if I have a galvanic isolator? Galvanic isolators only protect against galvanic action. They will not block corrosion currents driven by more than 1.5 volts that can be highly destructive to your boat. GalvanAlert will detect such currents so you can protect your boat in instances where galvanic isolators do not.
BOAT SIDE
FEMALE CONNECTOR Attaches to boat inlet or cordset
G
DOCK SIDE
MALE PLUG Attaches to dockside receptacle or cordset
W
199128
W W W
Provides safer hook-up to 30A dockside power Provides protection against harmful electric shock Reduces the possibility of fire Offers protection for up to 3 attached tools Corrosion resistant and rain-proof rated for outdoor use GFI trip level of 46 mA
Can also be used for other outdoor, harsh environments such as construction sites or wherever ground fault protection is desired. Note: A Ground Fault Circuit Interrupter (GFCI) limits the duration of an electrical shock to a period considered safe for healthy people. It does not prevent electric shock. This device does not protect against electric shock due to contact with both circuit conductors or a fault in any wiring supplying this device.
22
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
30 AMP
125V
30 AMP
125V
30 AMP
125V
Male Plug
NOTE: Di erent AMPS icons Item # on di erent layers 305CRPN
Female Connector
NOTE: Di erent AMPS icons Item # on di erent layers 305CRCN
cover
OEM # 305CRPN.OEM
OEM # 305CRCN.OEM
Item # 305CRPN.VPK
30 AMP
125V
30 AMP
125V
30 AMP
125V
Locking Receptacle
NOTE: Di erent AMPS icons Corrosion on di erent layers
Locking Receptacle
NOTE: Di erent AMPS icons Corrosion on di erent layers
30 AMP
125V
30 AMP
125V
30 AMP
125V
weatherproof Cover
or 205CRPN Item # 102N
30 AMP
125V
30 AMP
125V
30 AMP
125V
Item # 100EL
Item # 100R
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
23
50 AMP
125V
50 AMP
125V
50 AMP
125V
Male Plug
2 pole, 3 wire Item # 6361CRN
Female Connector
2 pole, 3 wire Item # 6360CRN OEM # 6360CRN.OEM
125/250V
50 AMP
125/250V
50 AMP
125/250V
50 AMP
Male Plug
3 pole, 4 wire Item # 6365CRN OEM # 6365CRN.OEM
Female Connector
3 pole, 4 wire Item # 6364CRN OEM # 6364CRN.OEM
weatherproof Cover
Use with 6361CRN or 6365CRN Can be used on both Male & Female ends Item # 7717N OEM # 7717N.OEM Item # 102182 yellow yellow white
24
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
15 AMP
125V
15 AMP
125V
15 AMP
125V
Male Plug
Straight blade Item # 5266CR
Female Connector
Straight blade Item # 5269CR
Male Plug
Locking type Item # 4721CR
15 AMP
125V
15 AMP
125V
15 AMP
125V
Female Connector
Locking type Item # 4731CR
20 AMP
125V
20 AMP
125V
20 AMP
125V
Male Plug
Straight blade Item # 5366CR OEM # 5369CR.OEM
Female Connector
Straight blade OEM # 5369CR.OEM
Male Plug
Locking type Uses weatherproof cover 102N Item # 205CRPN
20 AMP
125V
20 AMP
125V
20 AMP
125V
Female Connector
Locking type Uses weatherproof cover 103RN Item # 205CRCN
Locking Receptacle
Item # 205CRR
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
25
Weatherproof Cover
Use with 5366CR or 5266CR Item # 6017Y
Weatherproof Cover
Use with 5369CR or 5269CR plugs Item # 6018Y
Weatherproof Cover
Can be used on 15 & 20 amp OEM # 1520bI.OEM
15 AMP
125V
Cable Clips
ncludes 6 Cable Clips with I stainless steel mounting screws eeps shore power cable out of K the water olds 10 gauge 30A cable H Easy to install se on deck or edge of dock U O rganize shore power cable Item # CLIP
Organizer Bag
eavy duty nylon zippered bag H with handle deal for storing cordsets I and adapters Item # BAg
26
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
FS Box
Black non-metallic, with two 3/4" K.O. holes Accepts 15A, 20A and 30A receptacles, and 7420CR weatherproof covers Item # 6080
weatherproof Cover
Yellow LEXAN polycarbonate with lift lid Fits 15A, 20A, & 30A single receptacles Item # 7420CR OEM # 7420CR.OEM
weatherproof Cover
Yellow LEXAN polycarbonate with lift lid Fits 50A receptacles 6369CR & 6370CR Item # 7788CR
Replacement Interior
Fits 50A 125/250V Easy Lock 4-wire stainless steel or standard inlets manufactured after 8-1-93 Item # 6373ELMB
Replacement Interior
Fits 303SSEL-B, 303SSI-B & 301EL-B boat inlets Item # 305CRMB
Replacement Interior
Fits 30A standard non-metallic inlets manufactured prior to 1/1/91 Item # 301CRMB
warning Labels
For use on standard inlets For warning label placement use per ABYC standards Item # INLET.LABEL.30A 30A Item # INLET.LABEL.50A 50A
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
27
NEMA L7-15P
G 230V
16A
Meets or Exceeds
Locking
Standards
Standard Inlet
Easy Lock system Glass-filled polyester Watertight Rear safety enclosure with strain relief
Contour Inlet
Easy Lock system Glass-filled polyester Watertight Rear safety enclosure with strain relief
Female Connector
Corrosion resistant contacts and terminals Use with cover 103RN and cap 199109 Item # 305CRCXNPK OEM # 305CRCXN
Connector Kit
Includes female connector, weatherproof cover with threaded ring and watertight cap Item # 199114
28
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
NEMA L11-15P
Z
X 230V
32A
Meets or Exceeds
Connect | International
Locking
Standards
Standard Inlet
Easy Lock system Glass-filled polyester Watertight Rear safety enclosure with strain relief
Contour Inlet
Easy Lock system Glass-filled polyester Watertight Rear safety enclosure with strain relief
OEM # 6351EL-BX
OEM # 6343EL-BX
Female Connector
Corrosion resistant contacts and terminals Use with cover 7715CRN and sealing cap 199110 Item # 6360CRNXPK OEM # 6360CRNX
Connector Kit
Includes female connector, weatherproof cover with treaded ring and watertight cap Item # 199115
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
29
NEMA L9-60P
Y
G 230V
63A
Meets or Exceeds
Locking
Standards
Female Connector
Corrosion resistant contacts and terminals Item # 6401CRCX
Male Connector
Corrosion resistant contacts and terminals Item # 6401CRPX
Item # 6401EL-BX
X G Y
Meets or Exceeds
Standards
Female Connector
Corrosion resistant contacts and terminals Item # 6402CRCX
Male Connector
Corrosion resistant contacts and terminals Item # 6402CRPX
Item # 6402EL-BX
30
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect | International
Adapter
CEE-7/7 connector to CE plug LED power indicator Wear-proof, UV resistant cable Item # 121160900
Adapter
CE connector to CEE-7/7 plug Wear-proof, UV resistant cable Item # 121160910
Splitter
LED power indicator Wear-proof, UV resistant cable Item # 121160920
Practical tips Based on the maximum load for onboard power consumption, choose either a 16A or a 32A connection. For high loads choose multiple parallel connections to shore. Choose the appropriate connection to the shore: Standard is an earthed two-pole plug or the more familiar blue CEE three-pole plug.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
31
Connector Body
Mate with plug on extension cords or adapters. Note: It does not mate with shore power inlet. Item # M4100C12
Dockside Receptacle
Spring loaded cover providing a IP67 watertight rating when tightened. Item # M4100R12
Dockside Receptacle
Spring loaded cover providing a IP67 watertight rating when tightened. Item # M4100R12
Connector Body
Mate with plug on extension cords or adapters. Note: It does not mate with shore power inlet. Item # M5100C9
Dockside Receptacle
Spring loaded cover providing a IP67 watertight rating when tightened. Item # M5100R9
Dockside Receptacle
Spring loaded cover providing a IP67 watertight rating when tightened. Item # M5100B9R
32
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect: DC Connections
Connect | DC Connections
SeaLink 12 Volt
Slide-LocTM Locking Ring Watertight Cap Interchangeable Fuse Cord Seal Panel with 1-1/8" Diameter Opening Internal Strain Relief LED Indicator Light
Plated Brass Electrical Contacts Weather Resistant Cover Internal Strain Relief
SEALINK Receptacle
SEALINK Plug
The SeaLink 12 volt family of products are manufactured from corrosion resistant marine grade materials. Exclusive to SeaLink products is a unique interconnecting system that securely locks the plug into the receptacle resulting in a positive and moisture-proof connection. The plug and receptacle feature optimized metal connection points for maximum conductivity.
The ConnectPro trolling motor plug and receptacle is a revolutionary concept in trolling motor DC connections. The ConnectPro system has superior electric current carrying capacity that eliminates problems that rob motors of power and reduce battery life. The ConnectPro system features locking plug and receptacle and spring clamping connection which provides a secure electrical contact.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
33
Connect: DC Connections
Item # 12VXC
34
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect: DC Connections
Connect | DC Connections
Boot
For use with 12V products Creates a weatherproof seal Item # 300275
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
35
Connect: DC Connections
PATENTED
ConnectPro Receptacle
Universal design for 2 or 3-wire configuration 12, 24, 12/24, 24/36 or 36 volt systems Watertight sealing cap Corrosion resistant, plated brass electrical components Drain holes in receptacle keep water away from electrical components Perma-Lock screw terminals will not loosen under extreme hull vibration Standard 1-1/8" diameter mounting hole Easy to install, with supplied mounting plate for front panel installation, or locking ring for rear access installation Accepts 10 and 8 gauge wire Easily replaces other trolling motor plugs and receptacles Item # 12VBR Item # 12VBR.PG OEM # 12VBR.OEM w/ Old Style Ring Item # 12VBRO w/ gasket
ConnectPro Plug
O-ring seal for waterproof connections Weather resistant plug cover Corrosion resistant, plated brass electrical components Accepts 16 to 8 gauge wire Ergonomic contoured grip for easy hook-up and ground blade alignment Item # 12VBP OEM # 12VBP.OEM
ConnectPro Receptacle
Works with 12, 24, or 36 volt 2-wire systems For front mount panel installations Weather resistant sealing cap Drain holes in receptacle keep water away from electrical components Perma-Lock screw terminals will not loosen under extreme hull vibration Fits standard 1-1/8" diameter mounting hole Accepts up to 10 gauge wire Item # 12VBRS2 OEM # 12VBRS2.OEM
ConnectPro Plug
O-ring seal for waterproof connections Weather resistant plug cover Corrosion resistant, plated brass electrical components Accepts 16 to 8 gauge wire Ergonomic contoured grip for easy hook-up and ground blade alignment Max. rating is 40 amps Item # 12VBPS2 OEM # 12VBPS2.OEM
36
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Connect: DC Connections
Connect | DC Connections
Male Plug
Short housing, black nylon with internal strain relief system and recessed fasteners Item # 305BP OEM # 305BP.OEM
Female Connector
Short housing, black nylon with internal strain relief system and recessed fasteners Item # 305BC
Receptacle
Corrosion resistant reinforced nylon. Accepts 8 gauge stranded wire or up to 6 gauge with ring terminals Item # 305CRRB OEM # 305CRRB.OEM
W
NEMA G L5-30R
Bracket
Spring loaded flip lid cover, without receptacle Item # 2018MB OEM # 2018MB.OEM
Receptacle
Glass-reinforced corrosion resistant nylon. Accepts 8 gauge stranded wire or up to 6 gauge with ring terminals. Item # 2018BR OEM # 2018BR.OEM OEM # 2018BR.OEM.BPS (case pack)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
37
38
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Generate
Hybrid Power ___________________________________________40 Alternators & Charge Regulators __________________________43 Solar ChargeMaster ______________________________________46
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
39
Green at heart
Green at heart and with 10 kW of starting power, the GPX offers 2 kW of continuous power via the Mastervolt batteries. The diesel engine is only activated in case of a continuous load of more than 2 kW. This way the GPX saves fuel, materials, space and weight. Smaller generator required due to auxiliary batteries for peak loads. No inefficient running of the generator, lower fuel consumption. 10 to 20% more efficient conversion of the rotating diesel power via the permanent magnet generator. No power loss due to conversion of generator energy via the batteries to the inverter. Compact size saves space and weight.
40
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Combined power Combines shore power, battery power and generator power in the most economical way.
Perfect AC power The AC output is controlled by power electronics and ensures a perfect AC power. Even while running the generator and turning on and off heavy loads.
State-of-the-art technology Variable speed generator with ultra-efficient permanent magnet alternator.
Total energy system The GPX fits perfectly in an e-propulsion system, thanks to the smart integration of inverter, generator, battery charger and transfer system. To use the Mastervolt GPX in a system, check the Mastervolt Powerbook Systems.
Mastervolt will introduce higher capacities with GPX technology. Keep checking mastervolt.us/gpx for the latest information.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
41
PRELIMINARY SPECS
GPX-6.5 Item # General Specifications Output voltage Peak output (silent) Output power (silent) Propulsion* power (silent) Output power (running) Propulsion* power (running) Dimensions, hxwxd Weight (dry weight) Low Voltage DC Specifications Battery voltage Battery charging current Min. battery capacity Battery type settings Charge characteristic Alternator Specifications Type Cont. rated power Diesel Engine Specifications Number of cylinders Cylinder capacity Engine cooling Governing system Max. current Ground relay Transfer relay & RCD Technical Specifications Temperature range operational Protection degree Relative humidity AC connections DC connections Communication ports MasterBus Connection temperature sensor Options MasterView Easy 77010305 MasterView System 77010400 MasterShunt 77020100 Temperature sensor delivered as standard delivered as standard touch screen to control and monitor all MasterBus compatible products delivered as standard -20C to 40C, >40C derating / -4F to 104F, >104F derating IP23 IP23 IP23 max. 95% non condensing, protected against humidity and condensing air by conformal coating on both sides of all PCBs terminal block screw terminal M10 2x RJ45 1x RJ11 terminal block screw terminal M10 2x RJ45 1x RJ11 terminal block screw terminal M10 2x RJ45 1x RJ11 1 300 cc indirect water cooled electronic 32A yes yes 1 300 cc indirect water cooled electronic 32A yes yes 1 300 cc indirect water cooled electronic 32A yes yes brushless permanent magnet alternator 3000 rpm 4.2 kW 3000 rpm 4.2 kW 3000 rpm 4.2 kW 12/24/48V 120/80/40A 320/160/80 Ah standard Mastervolt 3-step 12/24/48V 120/80/40A 400/200/100 Ah standard Mastervolt 3-step 12/24/48V 120/80/40A 600/320/160 Ah standard Mastervolt 3-step 230V / 50Hz 10 kW (5 seconds) 2.5 kW cont. n.a. 6.5 kW cont. n.a. 27.6"x17.9"x20.7" 700x455x525 mm 176.4 lbs / 80 kg 230V / 50Hz 10 kW (5 seconds) 2.5 kW cont. 4 kW cont. 6.5 kW cont. 8 kW cont. 31.5"x17.9"x20.7" 800x455x525 mm 194 lbs / 88 kg 230V / 50Hz 10 kW (5 seconds) 2.5 kW cont. 8 kW cont. 6.5 kW cont. 12 kW cont. 35.4"x17.9"x20.7" 900x455x525 mm 211.6 lbs / 96 kg GPX-8E* GPX-12E*
--
--
--
optional optional optional color touch screen to control and monitor your complete Mastervolt system provides state of charge information delivered as standard delivered as standard delivered as standard
* The GPX E contains an additional module, which is the controller for the electric motor in an E-propulsion system. Now it is a real one box for all solution; just connect the power cables of your electric motor to the GPX and you can drive the boat. Another advantage of the integrated motor control is the high overall efficiency, by taking the power directly from the source (grid, batteries, or diesel) with minimal conversion steps. A true hybrid power solution saving labor, costs, and energy, resulting in a simple and reliable installation.
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/gpx
42
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Tip: Become independent of shore power and choose a powerful charge system on your main engine.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
43
Fast charging, even at a stationary rpm Standard alternator only supply the specified capacity at a high rpm. The Mastervolt Alpha generator was specifically designed to charge powerfully, even with a low engine rpm.
For all engine types Alpha alternators are equipped with several fixations for customized alternator brackets, available from your installer or engine supplier. Some engine brands come with Mastervolt alternator brackets as an option.
Multi-belt pulley The 12/130 and 24/75 models are also available with a multi-belt pulley.
Performs above 40C Forced cooling via the ventilator action of the pulley provides a lot of power in higher temperatures, even in enclosed engine rooms where the temperature can easily rise above 40C.
Alpha Pro charge regulator: Easy to install The Alpha Pro charge regulator is equipped with a microprocessor for Mastervolts 3-step charging method and fastening connections for the included cable to the alternator. Also included is a telejack plug for the temperature sensor that is to be connected to the largest and warmest battery. The charge regulator has a functional, waterproof design (IP65) and features electronics housed inside synthetic material.
44
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
12/90 Item # Type cabinet Charge current Alpha Pro charge regulator Charge voltage absorption Charge voltage float Cable length regulator/alternator Pulley (double) diameter Belt section Isolated from mass Directions of revolutions Weight Dimensions Mounting 48012090 A 90A standard 14.25V 13.25V 73 mm 2xA yes 2 12.1 lbs 5.5 kg five to six, six oclock & five past six
12/130* 48012130 B 130A standard 14.25V 13.25V 88 mm 2xA yes 2 22.3 lbs 10.1 kg six oclock
24/75* 48024075 B 75A standard 28.5V 26.5V 88 mm 2xA yes 2 22.3 lbs 10.1 kg six oclock
24/95C 46020950 D 95A standard 28.5V 26.5V 76,4 mm 2xA yes 1 (clockwise) 17.4 lbs 7.9 kg five past six
24/110 48024110 B 110A standard 28.5V 26.5V 88 mm 2xA yes 2 22.3 lbs 10.1 kg six oclock
24/150 48024150 C 150A standard 28.5V 26.5V 92 mm 2xA yes 2 28.9 lbs 13.1 kg five to six, six oclock & five past six
1.5 meter / 4.9 ft, oil resistant marine connection cable delivered as standard
Charge regulation
the Alpha Pro regulator is standard with all models, see table hereunder
* Available with multi-belt pulley (12/130 model = 48012131, 24/75 model = 48024076).
Item # Charge voltage bulk/absorption* Charge voltage float* Adjustability bulk Adjustability float Temperature compensation Absorption time Cable length regulator/alternator Connection plug regulator/alternator Cable length temperature sensor Protection degree Dimensions, hxwxd Weight Suitable for alternator type
4 hours, adjustable from 2 minutes to 12 hours 1.5 metre / 4.9 ft, oil resistant marine connection cable delivered as standard Alpha/Mastervolt 19.7' / 6 m IP65 3.5"x3.7"x1.2" 90x95x30 mm 0.9 lbs / 0.4 kg various Alpha/Mastervolt 19.7' / 6 m IP65 3.5"x3.7"x1.2" 90x95x30 mm 0.9 lbs / 0.4 kg various Alpha/Bosch 19.7' / 6 m IP65 3.5"x3.7"x1.2" 90x95x30 mm 0.9 lbs / 0.4 kg Bosch Alpha/Bosch 19.7' / 6 m IP65 3.5"x3.7"x1.2" 90x95x30 mm 0.9 lbs / 0.4 kg Bosch
* Voltage at 25C / 77F (with connected temperature sensor 14.4/28.8V at 20C / 68F). In Q2 2012 also available with MasterBus. Please check the Mastervolt site for the latest information.
For detailed specifications, scale drawings, 3D files, certificates, and manuals see mastervolt.us/alternators.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
45
SCM-N 20 Item # Charge current Max. DC load Solar input voltage window System voltage (battery) No load Functions LCD display Connections Settings Dimensions, hxwxd Protection degree cabinet Weight PC-Link 131802000 20A 20A 1250V DC 12/24V auto detect < 4 mA screw terminal 5.5"x4.1"x1.6" 140x105x41 mm IP20 2 lbs / 189 gr 21730400 option
SCM-N 40 131804000 40A 40A 1250V DC 12/24V auto detect < 4 mA screw terminal 5.5"x4.1"x1.6" 140x105x41 mm IP20 2 lbs / 189 gr 21730400 option
46
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
48
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Convert
Battery Chargers ________________________________________50 ChargeMaster Specifications 12V ________________________52 ChargeMaster Specifications 24V ________________________54 Mass Specifications 12, 24 & 48V ________________________56 ICS Battery Chargers 120V ______________________________58 Charge Pro Chargers___________________________________59 ConnectCharge Inlets & Crusing Series Chargers __________60 Maintainers/Chargers ____________________________________61 Sine Wave Inverters ______________________________________62 AC Master Specifications 230V __________________________64 Mass Sine Specifications 230V / 120V ____________________66 Mass Combi ____________________________________________68 DCDC Converters ______________________________________74 DC Master Specifications _________________________________76 Mac & Magic Specifications_______________________________78 Isolation Transformers ____________________________________80
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
49
50
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
The best battery charger for every application The ChargeMaster can charge multiple battery banks at once, providing the ease and comfort of combined functionalities. The Mass battery charger has one main outlet to optimally charge a battery bank and guarantee a long lifespan for your batteries even with daily and intensive use. The second outlet is used for the maintenance charge of your starter battery.
Charging Lithium Ion batteries Although Lithium Ion batteries are increasingly popular, there can be a lack of clarity when it comes to the charging process. This is not a problem with a Mastervolt system as the Mastervolt battery charger communicates directly with the Li-ion battery.
MasterBus compatible All ChargeMaster & Mass battery chargers can be easily connected to a MasterBus network with only one cable and one connection. Whats more, you have the option for central, local or remote monitoring, configuration and control of your system.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
51
ChargeMaster 12/10-1 Item # General Specifications Nominal output voltage Total charge current Number of battery outlets Charge current second output Charge current third output Recommended battery capacity Nominal input voltage AC connection Supplies your system without battery Display/read-out Dimensions, hxwxd Weight Fastening Approvals Technical Specifications Charge characteristic** Charge voltage Bulk (25C)*** Charge voltage Absorption (25C)*** Charge voltage Float wet (25C)*** Charge voltage Float gel/AGM (25C)*** Temperature compensation Voltage compensation DC consumption Full load consumption (230V AC) Current Control function Cos phi Temperature range (ambient temp.) Cooling Sound level Protection degree Protections MasterBus compatible CSI/DC alarm Options MasterView Read-out 77010050 MasterView Easy 77010305 MasterShunt 77020100 MasterBus USB Interface 77030100 n.a. n.a. n.a. n.a. IUoUo, automatic / 3-step 14.25V (6 hours) 14.25V (6 hours) 13.25V 13.8V no automatic <1 mA 170 W no >0.95 -25C60C, >40C derating -13F140F, >104F derating natural cooling <30 dbA at 1 mtr IP65 no no 12V 10A at 14.25V 1 n.a. n.a. 25100 Ah 230V (180265V) 50/60Hz socket no 1 LED 7.1"x4.8"x2" 180x121x50 mm 1 kg / 2.2 lbs screw CE, E-mark, ABYC A-31 43011000
ChargeMaster 12/15-2 43011500 12V 15A at 14.25V 2 15A n.a. 30150 Ah 230V (180265V) 50/60Hz socket no 1 LED 8.1"x4.8"x2" 206x121x50 mm 1 kg / 2.2 lbs screw CE, E-mark, ABYC A-31 for gel/AGM/wet/Lithium Ion 14.25V (6 hours) 14.25V (6 hours) 13.25V 13.8V no automatic <1 mA 250 W no >0.95 -25C60C, >40C derating -13F140F, >104F derating <52 dBA at 1 mtr IP21 no no n.a. n.a. n.a. n.a.
ChargeMaster 12/25-3 44010250 12V 25A at 13.25V 3 25A 25A 50250 Ah 120/230V (90265V) 50/60Hz 2 mtr AC cable yes LED display 9.2"x5.2"x2.4" 234x132x60 mm 1,8 kg / 4 lbs screw CE, E-mark, ABYC A-31, SAE...
14.4V (8 hours) 14.25V (4 hours) 13.25V 13.8V -30 mV/C or -17 mV/F automatic <2 mA 450 W no 0.98 -25C60C, >25C derating -13F140F, >77F derating <52 dBA at 1 mtr IP23 yes yes, using a... Remote panel for reading the charge status of your battery... Touch screen panel for reading charge status, current fold-back... MasterBus integrated battery monitor, with detailed... Communication port between MasterBus and the USB port of... MasterBus controllable potential-free contact, with...
over temperature, over load, short circuit, high battery, low battery
Multipurpose Contact Output n.a. n.a. 77030500 * At request also available with 90400V DC input voltage. ** The charge characteristic can be set to your requirements. *** The battery charge current can sometimes be specified at 20C/68F, so take temperature compensation into account.
52
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
ChargeMaster 12/35-3 44010350 12V 35A at 14.4V 3 35A 35A 70350 Ah 120/230V (90265V) 50/60Hz connector strips yes LED display 11.5"x8.3"x5.2" 291x210x131 mm 4 kg / 9 lbs J1171/ISO 8846 ignition protected IUoUo, automatic / 3-step 14.4V (8 hours) 14.25V (4 hours) 13.25V 13.8V -30 mV/C or -17 mV/F automatic <5 mA 575 W yes, through MasterBus 0.98 -25C60C, >40C derating -13F140F, >104F derating <52 dBA at 1 mtr IP23 yes
ChargeMaster 12/50-3 44010500 12V 50A at 14.4V 3 50A 50A 100500 Ah 120/230V (90265V) 50/60Hz connector strips yes LED display 11.5"x8.3"x5.2" 291x210x131 mm 4 kg / 9 lbs
ChargeMaster 12/70-3* 44010700 12V 70A at 14.4V 3 10A 10A 140700 Ah 120/230V (90265V) 50/60Hz connector strips yes LCD display 14.3"x11"x5.9" 362x277x150 mm 7 kg / 16 lbs
ChargeMaster 12/100-3* 44011000 12V 100A at 14.4V 3 10A 10A 2001000 Ah 120/230V (90265V) 50/60Hz connector strips yes LCD display 14.3"x11"x5.9" 362x277x150 mm 7 kg / 16 lbs
with the supplied mounting bracket or 4x screw for wall mounting or 4x screw for floor installation
for gel/AGM/wet/Lithium Ion 14.4V (8 hours) 14.25V (4 hours) 13.25V 13.8V -30 mV/C or -17 mV/F automatic <5 mA 825 W yes, through MasterBus 0.98 -25C60C, >40C derating -13F140F, >104F derating <52 dBA at 1 mtr IP23 yes 14.4V (8 hours) 14.25V (4 hours) 13.25V 13.8V -30 mV/C or -17 mV/F automatic <5 mA 1200 W yes, through MasterBus 0.98 -25C60C, >40C derating -13F140F, >104F derating <52 dBA at 1 mtr IP23 yes 14.4V (8 hours) 14.25V (4 hours) 13.25V 13.8V -30 mV/C or -17 mV/F automatic <5 mA 1700 W yes, through MasterBus 0.98 -25C60C, >40C derating -13F140F, >104F derating <52 dBA at 1 mtr IP23 yes
over temperature, over load, short circuit, high battery, low battery Multipurpose Contact Output (Item # 77030500 ) charger, including error notifications. and/or Power Sharing setting. information on the status of your batteries for a optimized charging process, incl. voltage, current, remaining time and consumption capacity in percentage. your PC; makes possible reading and configuration of your MasterBus system on the PC when combined with MasterView System software (free to download). alarm notification on the onboard system (low voltage or no AC), replacement of the CSI alarm contact.
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/chargers.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
53
ChargeMaster 24/6-1 Item # General Specifications Nominal output voltage Total charge current Number of battery outlets Charge current second output Charge current third output Recommended battery capacity Nominal input voltage AC connection Supplies your system without battery Display/read-out Dimensions, hxwxd Weight Fastening Approvals Technical Specifications Charge characteristic** Charge voltage Bulk (25C)*** Charge voltage Absorption (25C)*** Charge voltage Float wet (25C)*** Charge voltage Float gel/AGM (25C)*** Temperature compensation Voltage compensation DC consumption Full load consumption (230V AC) Current Control function Cos phi Temperature range (ambient temp.) Cooling Sound level Protection degree Protections MasterBus compatible CSI/DC alarm 77030500 Options MasterView Read-out 77010050 MasterView Easy 77010305 MasterShunt 77020100 MasterBus USB Interface 77030100 Multipurpose Contact Output 77030500 n.a. n.a. n.a. n.a. n.a. IUoUo, automatic / 3-step 28.5V (6 hours) 28.5V (6 hours) 26.5V 27.6V no automatic <1 mA 210 W no >0.95 24V 6A at 28.5V 1 n.a. n.a. 2570 Ah 230V (180265V) 50/60Hz socket no 1 LED 7.1"x4.8"x2" 180x121x50 mm 1 kg / 2.2 lbs 4x screw CE, E-mark, ABYC A-31 43020600
ChargeMaster 24/12-3 44020120 24V 12A at 26.5V 3 12A 12A 24120 Ah 120/230V (90265V) 50/60Hz 2 mtr AC cable yes LED display 9.2"x5.2"x2.4" 234x132x60 mm 1.8 kg / 4 lbs 4x screw
ChargeMaster 24/20-3 44020200 24V 20A at 28.8V 3 20A 20A 40200 Ah 120/230V (90265V) 50/60Hz connector strips yes LED display 11.5"x8.3"x5.2" 291x210x131 4 kg / 9 lbs 4x screw
ChargeMaster 24/30-3 44020300 24V 30A at 28.8V 3 30A 30A 60300 Ah 120/230V (90265V) 50/60Hz connector strips yes LED display 11.5"x8.3"x5.2" 291x210x131 4 kg / 9 lbs 4x screw
CE, E-mark, ABYC A-31, SAE J1171/ISO 8846 ignition protected for gel/AGM/wet/Lithium Ion 28.8V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F automatic <2 mA 435 W no 0.98 28.8V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F automatic <2.5 mA 660 W yes, through MasterBus 0.98 28.8V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F automatic <2.5 mA 925 W yes, through MasterBus 0.98
-25C60C, >40C derating -25C60C, >25C derating -25C60C, >40C derating -13F140F, >104F derating -13F140F, >77F derating -13F140F, >104F derating natural cooling <30 dbA at 1 mtr IP65 no no -13F140F, >77F derating <52 dBA at 1 mtr IP23 yes <52 dBA at 1 mtr IP23 yes <52 dBA at 1 mtr IP23 yes
over temperature, over load, short circuit, high battery, low battery yes, using a Multipurpose Contact Output
Remote panel for reading the charge status of your battery charger, incl. error notifications. Touch screen panel for reading charge status, current fold-back and/or Power Sharing setting. MasterBus integrated battery monitor, with detailed information on the status of your batteries for a optimized charging process, incl. voltage, current, remaining time... Communication port between MasterBus and the USB port of your PC; makes possible reading and configuration of your MasterBus system on the PC when... MasterBus controllable potential-free contact, with alarm notification on the onboard system (low voltage or no AC), replacement of the CSI alarm contact.
* At request also available with 90400V DC input voltage. ** The charge characteristic can be set to your requirements. *** The battery charge current can sometimes be specified at 20C/68F, so take temperature compensation into account.
54
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
ChargeMaster 24/40-3* 44020400 24V 40A at 28.8V 3 10A 10A 80400 Ah 120/230V (90265V) 50/60Hz connector strips yes LCD display 14.3"x11"x5.9" 362x277x150 7 kg / 16 lbs
ChargeMaster 24/60-3* 44020600 24V 60A at 28.8V 3 10A 10A 120600 Ah 120/230V (90265V) 50/60Hz connector strips yes LCD display 14.3"x11"x5.9" 362x277x150 7 kg / 16 lbs
ChargeMaster 24/80-3* 44020800 24V 80A at 28.8V 3 10A 10A 160800 Ah 120/230V (90265V) 50/60Hz connector strips yes LCD display 17"x11"x5.9" 432x277x150 8 kg / 18 lbs
ChargeMaster 24/100-3* 44021000 24V 100A at 28.8V 3 10A 10A 2001000 Ah 120/230V (90265V) 50/60Hz connector strips yes LCD display 17"x11"x5.9" 432x277x150 8 kg / 18 lbs
with the supplied mounting bracket or 4x screw for wall mounting or 4x screw for floor installation CE, E-mark, ABYC A-31, SAE J1171/ISO 8846 ignition protected IUoUo, automatic / 3-step 28.8V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F automatic <5 mA 1400 W yes, through MasterBus 0.98 for gel/AGM/wet/Lithium Ion 28.8V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F automatic <5 mA 2000 W yes, through MasterBus 0.98 28.8V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F automatic <5 mA 2700 W yes, through MasterBus 0.98 28.8V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F automatic <5 mA 3375 W yes, through MasterBus 0.98
-25C60C, >40C derating -13F140F, >104F derating maintenance free vario fan for optimal cooling <52 dBA at 1 mtr IP23 yes <52 dBA at 1 mtr IP23 yes
-25C60C, >40C derating -13F140F, >104F derating <52 dBA at 1 mtr IP23 yes <52 dBA at 1 mtr IP23 yes
over temperature, over load, short circuit, high battery, low battery yes, using a Multipurpose Contact Output
Remote panel for reading the charge status of your battery charger, incl. error notifications. Touch screen panel for reading charge status, current fold-back and/or Power Sharing setting. and consumption capacity in percentage. combined with MasterView System software (free to download). MasterBus controllable potential-free contact, with alarm notification on the onboard system (low voltage or no AC), replacement of the CSI alarm contact.
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/chargers.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
55
Mass 12/60-2 Item # General Specifications Nominal output voltage Total charge current Number of battery outlets Charge current second output Recommended battery capacity Nominal input voltage Supplies your system without battery Display/read-out Dimensions, hxwxd Weight Approvals** Technical Specifications Charge characteristic*** Charge voltage Bulk (25C)**** Charge voltage Absorption (25C)**** Charge voltage Float wet (25C)**** Charge voltage Float gel/AGM (25C)**** Temperature compensation Voltage compensation DC consumption Full load consumption (230V AC) Cos phi Temperature range (ambient temp.) Cooling Sound level Protection degree Protections MasterBus compatible CSI/DC alarm (Charger Status Interface) GMDSS function Options MasterView Read-out 77010050 MasterView Easy 77010305 MasterShunt 77020100 MasterBus USB Interface 77030100 MasterVision panels IUoUo, automatic / 3-step 14.25V (8 hours) 14.25V (4 hours) 13.25V 13.8V -30 mV/C or -17 mV/F <1 mA 1100 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes 12V 60A at 14.25V 2 3A 120600 Ah yes LED display 13.4"x10.3"x5.1" 340x261x130 mm 4.6 kg / 10.1 lbs 40010606
Mass 12/80-2 40010806 12V 80A at 14.25V 2 3A 160800 Ah yes LED display 13.4"x10.3"x5.1" 340x261x130 mm 4.6 kg / 10.1 lbs
Mass 24/15-2 40020156 24V 15A at 28.5V 2 3A 30150 Ah yes LED display 12.8"x8.7"x4.4" 325x220x111 mm 3.3 kg / 7.3 lbs
Mass 24/25-2 40020256 24V 25A at 28.5V 2 3A 50250 Ah yes LED display 12.8"x8.7"x4.4" 325x220x111 mm 3.3 kg / 7.3 lbs
CE, E-mark, ABYC A-31 / RRR, RS, DNV, Lloyds, Bureau Veritas, Germanischer Lloyds for gel/AGM/wet/Lithium Ion 14.25V (8 hours) 14.25V (4 hours) 13.25V 13.8V -30 mV/C or -17 mV/F <1 mA 1400 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes 28.5V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F <1 mA 550 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes 28.5V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F <1 mA 880 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes
over temperature, over load, short circuit, high battery, low battery integrated in the battery charger as standard GMDSS panel is available for all models Remote panel for reading the charge status of your battery charger, including error notifications. Touch screen panel for reading charge status, current fold-back and/or Power Sharing setting. MasterBus integrated shunt, with detailed information on the status of your batteries for a optimized charging process, incl. voltage, current, remaining time and consumption capacity in percentage. Communication port between MasterBus and the USB port of your PC; makes possible reading and configuration of your MasterBus system on the PC when combined with MasterView System software... Model C3-RS 70403040 Masterlink MICC 70403105
* Available as option: second output 3A (Item # 21711000). ** Check our website for the certificates per model. *** The charge characteristic can be set to your requirements. **** The battery charge current can sometimes be specified at 20C/68F, so take temperature compensation into account.
56
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Mass 24/50-2 40020506 24V 50A at 28.5V 2 3A 100500 Ah yes LED display 13.4"x10.3"x5.1" 340x261x130 mm 4.6 kg / 10.1 lbs
Mass 24/75 40020756 24V 75A at 28.5V 1 n.a.* 150750 Ah yes LED display 13.4"x10.3"x5.1" 340x261x130 mm 7.7 kg / 17 lbs
Mass 24/100 40021006 24V 100A at 28.5V 1 n.a.* 2001000 Ah yes LED display 13.4"x10.3"x5.1" 340x261x130 mm 7.7 kg / 17 lbs
Mass 24/100-3ph 40031006 24V 100A at 28.5V 1 n.a.* 2001000 Ah 3x400V (360485V) yes LED display 16.5"x12.5"x5.1" 420x318x130 mm 7.7 kg / 17 lbs
Mass 48/25 40040256 48V 25A at 57V 1 n.a. 100500 Ah yes LED display 16.5"x12.5"x5.1" 420x318x130 mm 4.6 kg / 10.1 lbs
Mass 48/50 40040506 48V 50A at 57V 1 n.a. 100500 Ah yes LED display 16.5"x12.5"x5.1" 420x318x130 mm 7.7 kg / 17 lbs
CE, E-mark, ABYC A-31 / RRR, RS, DNV, Lloyds, Bureau Veritas, Germanischer Lloyds IUoUo, automatic / 3-step 28.5V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F <1 mA 1800 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes for gel/AGM/wet/Lithium Ion 28.5V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F <1 mA 2600 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes 28.5V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F <1 mA 3500 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes 28.5V (8 hours) 28.5V (4 hours) 26.5V 27.6V -60 mV/C or -33 mV/F <1 mA 3500 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes 57V (8 hours) 57V (4 hours) 53V 55.2V -120 mV/C or -62 mV/F <1 mA 1800 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes 57V (8 hours) 57V (4 hours) 53V 55.2V -120 mV/C or -62 mV/F <1 mA 3500 W >0.95 vario fan <48 dBA at 1 mtr IP23 yes
over temperature, over load, short circuit, high battery, low battery integrated in the battery charger as standard GMDSS panel is available for all models Remote panel for reading the charge status of your battery charger, including error notifications. Touch screen panel for reading charge status, current fold-back and/or Power Sharing setting. MasterBus integrated shunt, with detailed information on the status of your batteries for a optimized charging process, incl. voltage, current, remaining time and consumption capacity in percentage. (free to download). go to mastervolt.us/chargers for an extended overview of the MasterVision panels.
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/chargers
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
57
6 Amp Single Output Item # Remote Indicator Total Amps Outputs Amps per out Battery System Input Voltage Output Voltage AC DC Dimensions Weight 16061 16001-RI 6 1 6 12V only 95135V AC / 60Hz, 2.5A 12V 6' cord w/ ConnectCharge plug 4' with ring terminals 2.4" x 4.9" x 7.0" 61x124x178 mm 3.0 lbs
12 Amp Dual Output 16102 16003-RI 12 2 6/6 12V+12V or 24V 95135V AC / 60Hz, 3.5A 12V DC 6' cord w/ ConnectCharge plug 4' with ring terminals 3.0" x 7.1" x 6.6" 76x180x168 mm 4.5 lbs
18 Amp Triple Output On-Board Battery Charger 16153 16003-RI 18 3 6/6/6 12V+12V+12V or 12V+24V or 36V 95135V AC/60Hz, 4.5A 12V DC 6' cord w/ ConnectCharge plug 4' with ring terminals 3.0" x 7.1" x 9.8" 76x180x251 mm 6.0 lbs
20 Amp Dual Output On-Board Battery Charger 16202 16003-RI 20 2 10/10 12V, 12V, 12V+12V or 24V 95135V AC, 50/60Hz, 5A 12V DC 6' cord w/ ConnectCharge plug 4' with ring terminals 3.0" x 7.1" x 9.9" 76x180x251 mm 6.75 lbs
Remote Indicator
For use with ICS battery chargers 15' cable included Easy installation - plugs right into ICS battery chargers Item # 16001-RI
Remote Indicator
For use with ICS battery chargers 15' cable included Easy installation - plugs right into ICS battery chargers Item # 16003-RI
58
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
6 Amp Single Output Item # OEM # Total Amps Outputs Amps per out Battery System Input Voltage Output Voltage AC DC Dimensions Weight 2608A 2608A-B 6 1 6 12V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 4' with ring terminals 3.50" x 6.40" x 2.25" 89x163x57 mm 4.0 lbs
6 Amp Dual Output 2607A 2607A-B 6 2 3/3 12V+12V or 24V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 4' with ring terminals 3.50" x 6.40" x 2.25" 89x163x57 mm 4.0 lbs
10 Amp Dual Output 2610A 2610A-B 10 2 5/5 12V+12V 100130V AC / 60Hz 12V Studs Studs 5.50" x 7.75" x 2.42" 140x197x61 mm 5.6 lbs
10 Amp Dual Output 2611A 2611A-B 10 2 5/5 12V+12V or 24V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 4' with ring terminals 5.50" x 7.75" x 2.42" 140x197x61 mm 5.6 lbs
15 Amp Triple Output Item # Total Amps Outputs Amps per out Battery System Input Voltage Output Voltage AC DC Dimensions Weight 2613A 15 3 5/5/5 12V+12V+12V or 24V+12V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 4'/4'/6' with ring terminals 7.0" x 9.60" x 2.60" 178x244x66 mm 8.0 lbs
20 Amp Dual Output 2620A 20 2 10/10 12V+12V or 24V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 6' with ring terminals 7.0" x 9.60" x 2.60" 178x244x66 mm 8.0 lbs
25 Amp Triple Output 2623A 25 3 10/5/10 12V+12V+12V or 24V+12V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 6' with ring terminals 7.0" x 13.0" x 2.60" 178x330x66 mm 13.0 lbs
30 Amp Triple Output 2631A 30 3 10/10/10 12V+12V+12V or 24V+12V or 36V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 6' with ring terminals 7.0" x 13.0" x 2.60" 178x330x66 mm 13.0 lbs
35 Amp Four Output OEM # Total Amps Outputs Amps per out Battery System Input Voltage Output Voltage AC DC Dimensions Weight 2635-B 35 4 5/10/10/10 12V+12V+12V+12V or 24V+12V+12V or 36V+12V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 6' with ring terminals 6.5" x 16.10" x 2.50" 165x409x64 mm 24.0 lbs
10 Amp Single Output 2611A-1-B 10 1 10 12V 100130V AC / 60Hz 12V 6' cord w/ ConnectCharge plug 4' with ring terminals 5.50" x 7.75" x 2.42" 140x197x61 mm 5.6 lbs
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
59
ConnectCharge Inlets
For use with Battery chargers with ConnectCharge Plug only!
Universal Mount
Mount to dash from rear with threaded locking ring or from the front with three screws through the face plate Item # 150CCI
Rear Mount
Mounts to dash from rear with threaded locking ring Eliminates rewiring, plug snaps into Inlet locking tab Watertight lid protects AC plug OEM # 150CCTM.OEM
Front Mount
Mounts to panel from front with three screws through the face plate OEM # 150CC.OEM
Cruising Series
Guest Cruising Chargers are made specifically for a coastal, blue water environment where top quality, rugged equipment is required. They feature individual circuit boards, which provide each battery its own specific charging circuit. The benefit is a well-designed charging system that protects your battery investment. Guest Cruising Chargers also function as a continuous 12 volt power supply to run your DC accessories while at the dock. Dedicated output per battery, each battery receives individual attention Provides different charging amperages as required by each battery
15 Amp Dual Output Item # Total Amps Outputs Amps per out Battery System Input Voltage Output Voltage AC DC Dimensions Weight 2614A 15 2 5/10 12V+12V 100130V AC / 60Hz 12V Studs Studs 2.92" x 9.60" x 9.84" 74x244x250 mm 10.8 lbs / 4.9 kg
20 Amp Dual Output 2622A 20 2 10/10 12V+12V 100130V AC / 60Hz 12V Studs Studs 2.92" x 9.60" x 9.84" 74x244x250 mm 10.8 lbs / 4.9 kg 230V 50/60Hz input model Item # 2622A-230
20 Amp Triple Output 2621A 20 3 5/5/10 12V+12V+12V 100130V AC / 60Hz 12V Studs Studs 2.92" x 9.60" x 9.84" 74x244x250 mm 10.8 lbs / 4.9 kg
30 Amp Triple Output 2632A 30 3 5/5/20 12V+12V+12V 100130V AC / 60Hz 12V Studs Studs 2.92" x 12.96" x 9.84" 74x329x250 mm 15.6 lbs / 7.1 kg 230V 50/60Hz input model Item # 2632A-230
30 Amp Dual Output 2633A 30 2 10/20 12V+12V 100130V AC / 60Hz 12V Studs Studs 2.92" x 12.96" x 9.84" 74x329x250 mm 15.6 lbs / 7.1 kg
60
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Convert: Maintainers/Chargers
Name: Item # Total Amps: Outputs: Amps per out: Battery System: Input Voltage: Output Voltage: AC: DC: Dimensions: Weight:
.5 Amp Battery Maintainer 2602 0.5 1 500mA/250mA 12V 100130V AC/60Hz 12V 6' AC cord with standard plug 4' with battery clips 1.50" x 3.0" x 2.0" 38x76x51 mm 0.5 lbs / 0.2 kg
2 Amp Battery Charger 2602A-12 2 1 2 12V 100130V AC/60Hz 12V 6' cord with ConnectCharge plug 4' with ring terminals 2.75" x 4.50" x 1.50" 70x114x38 mm 2.0 lbs / 0.9 kg
3 Amp Battery Charger 2603 3 1 3 12V 100130V AC/60Hz 12V 6' AC cord with standard plug 4' with battery clips 3.10" x 3.50" x 2.34" 79x89x59 mm 1.0 lbs / 0.5 kg
Name: Item # OEM # Total Amps: Outputs: Amps per out: Battery System: Input Voltage: Output Voltage: AC: DC: Dimensions: Weight:
2 Amp Battery Charger 2602A-24-B 2 1 2 24V 100130V AC / 60Hz 24V 6' AC cord with standard plug 4' with battery clips 2.75" x 4.50" x 1.50" 70x114x38 mm 2.0 lbs / 0.9 kg
6 Amp Battery Charger 2606A 2606A-B 6 1 6 12V 100130V AC / 60Hz 12V 6' AC cord with standard plug 4' with battery clips 5.5" x 5.0" x 2.4" 140x127x61 mm 3.5 lbs / 1.6 kg
10 Amp Battery Charger 2612A 10 1 10 12V 100130V AC / 60Hz 12V 6' AC cord with standard plug 4' with battery clips 7.5" x 5.0" x 2.4" 191x127x61 mm 4.5 lbs / 2 kg
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
61
62
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
An end to humming with HF technology Our use of high-frequency switch technology means you can say goodbye to humming transformers. Mastervolt inverters are also small and lightweight to ensure easy installation. High peak power during start up The Mastervolt sine wave inverter can provide up to 200% capacity to equipment that requires extra power during start up.
Simple and safe to connect The inverters benefit from robust connection technology with internal connections for the larger models and a cable and plug & play inlet for smaller models.
Efficient use of batteries A high degree of efficiency when inverting and the automatic economy mode when there is no consumption gives you longer use of your batteries and more hours on the water.
MasterBus compatible Thanks to the MasterBus Inverter Interface or AC power analyser, every Mass Sine inverter can be easily connected to a MasterBus network with only one cable and one connection. You can also choose for central, local or remote monitoring, configuration and control of your system.
Optimal ease of operation Mastervolts Mass Sine inverters are easy to operate via controls on the device, via a control panel or remote control text messaging. Plus numerous options for central or local control and monitoring via the MasterBus platform.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
63
AC Master 12/300 Item # 230V (universal socket) General Specifications Nominal battery voltage Recommended battery capacity Output voltage ( 5%) Continuous power at 25C, cos phi 1 Continuous power at 40C, cos phi 1 Peak load Output waveform Efficiency Display/read out Dimensions, hxwxd Weight Approvals Technical Specifications Technology Low battery voltage, switches off at Low battery voltage, switches on at High battery voltage, switches off at High battery voltage, switches on at Max. ripple on DC (battery) Input current (nominal load) No load power consumption: on mode (230V) standby (scan mode) Minimal DC fuse (slow blow)** Minimal cable size Harmonic distortion typical Cos Phi Temperature range (ambient temp.) Cooling Sound level Protection degree Protections MasterBus compatible AC connection HF switch mode 10V, 0.5V 11V, 0.5V 16V, 0.5V 14.5V, 0.5V 10% RMS 22.5A 0.58A 7 W 0.33A 4 W 40A included <6% all power factors allowed -25C60C, >25C derating -13F140F, >77F derating natural/forced 53 dBA at 1 mtr IP23 no universal 12V 60 Ah 230V 50Hz ( 0.1%) 300 W 250 W 600 W true sine 90% LED display 8.3"x5.1"x2.4" 210x130x60 mm 1.16 kg / 2.55 lbs CE, E-mark, ABYC A-31 28010300
AC Master 12/500 28010500 12V 100 Ah 230V 50Hz ( 0.1%) 500 W 400 W 800 W true sine 90% LED display 8.3"x5.1"x2.4" 210x130x60 mm 1.22 kg / 2.69 lbs CE, E-mark, ABYC A-31 HF switch mode 10V, 0.5V 11V, 0.5V 16V, 0.5V 14.5V, 0.5V 10% RMS 37.5A 0.58A 7 W 0.33A 4 W 80A included <6% all power factors allowed -25C60C, >25C derating -13F140F, >77F derating natural/forced 53 dBA at 1 mtr IP23 no universal
AC Master 12/750* 27510700 12V 150 Ah 230V 50Hz ( 0.1%) 750 W 600 W 1200 W true sine 90% LED display 10.8"x6.1"x3" 275x155x75 mm 2.7 kg / 5.4 lbs CE, E-mark, ABYC A-31 HF switch mode 10V, 0.5V 12V, 0.5V 15.3V, 0.5V 14.2V, 0.5V 5% RMS 64A 0.75A 9 W 0.37A 4.5 W 100A 25 mm2 <3% all power factors allowed -25C60C, >25C derating -13F140F, >77F derating natural/forced 53 dBA at 1 mtr IP23 no fixed connection
over temperature, over load, short circuit, high battery, low battery
* The AC Master 750 will be available in 2012, untill that date a 700 W version is available. ** DC fuse depends on the cable size.
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/inverters.
64
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
AC Master 24/300 28020300 24V 30 Ah 230V 50Hz ( 0.1%) 300 W 250 W 600 W true sine 91% LED display 8.3"x5.1"x2.4" 210x130x60 mm 1.16 kg / 2.55 lbs CE, E-mark, ABYC A-31 HF switch mode 20V, 0.5V 22V, 0.5V 32V, 0.5V 29V, 0.5V 10% RMS 11A 0.29A 7 W 0.16A 4 W 20A included <6% all power factors allowed -25C60C, >25C derating -13F140F, >77F derating natural/forced 53 dBA at 1 mtr IP23 no universal
AC Master 24/500 28020500 24V 50 Ah 230V 50Hz ( 0.1%) 500 W 400 W 800 W true sine 91% LED display 8.3"x5.1"x2.4" 210x130x60 mm 1.22 kg / 2.69 lbs CE, E-mark, ABYC A-31 HF switch mode 20V, 0.5V 22V, 0.5V 32V, 0.5V 29V, 0.5V 10% RMS 19A 0.29A 7 W 0.16A 4 W 40A included <6% all power factors allowed -25C60C, >25C derating -13F140F, >77F derating natural/forced 53 dBA at 1 mtr IP23 no universal
AC Master 24/750* 27520700 24V 75 Ah 230V 50Hz ( 0.1%) 750 W 600 W 1200 W true sine 90% LED display 10.8"x6.1"x3" 275x155x75 mm 2.7 kg / 5.4 lbs CE, E-mark, ABYC A-31 HF switch mode 21V, 0.5V 25V, 0.5V 30.6V, 0.5V 28.4V, 0.5V 5% RMS 32A 0.38A 9 W 0.19A 4.5 W 50A 10 mm2 <3% all power factors allowed -25C60C, >25C derating -13F140F, >77F derating natural/forced 53 dBA at 1 mtr IP23 no fixed connection
over temperature, over load, short circuit, high battery, low battery
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
65
Mass Sine 12/800 Item # 230V Item # 120V General Specifications Nominal battery voltage Minimum battery capacity Output voltage ( 5%) P30 power at 40C, cos phi 1 Continuous power at 40C, cos phi 1 Peak load Output waveform Efficiency Display/read-out Dimensions, hxwxd Weight Approvals Technical Specification Technology Low battery voltage, switches off at Low battery voltage, switches on at High battery voltage, switches off at High battery voltage, switches on at Max. ripple on DC (battery) Input current (nominal load) No load power consumption: on mode (230V) stand-by (scan mode) Minimal DC fuse (slow blow)* Minimal cable size Harmonic distortion typical Cos Phi Temperature range (ambient temp.) Cooling Sound level Protection degree Protections MasterBus compatible AC connection Options Model C4-RI 70404110 Masterlink/MICC 70403105 MasterBus Inverter Interface 77030700 AC power analyser 77031200 Transfer system * DC fuse depends on the cable size. HF switch mode 10V, 0.5V 11V, 0.5V 15.5V, 0.5V 14.5V, 0.5V 5% RMS 73A 470 mA 5.6 W 65 mA 0.8 W 100A 25 mm2 <5% all power factors allowed 12V >100 Ah 230V 50Hz ( 0 .01Hz) 800 W 650 W 1600 W true sine 92% LED display 12.8"x8.7"x4.4" 325x220x111 mm 3.9 kg / 8.6 lbs CE, E-mark, ABYC A-31 24010800
Mass Sine 12/1200 24011200 12V >150 Ah 230V 50Hz ( 0 .01Hz) 1200 W 1000 W 2400 W true sine 92% LED display 13.4"x10.3"x5.1" 340x261x130 mm 8 kg / 17.4 lbs CE, E-mark, ABYC A-31 HF switch mode 10V, 0.5V 11V, 0.5V 15.5V, 0.5V 14.5V, 0.5V 5% RMS 110A 450 mA 5 W 43 mA 0.5 W 150A 50 mm2 <5% all power factors allowed
Mass Sine 12/2000 24012000 25012000 12V >200 Ah 230V 50Hz ( 0 .01Hz) 2000 W 1800 W 4000 W true sine 92% LED display 16.5"x12.5"x5.4" 420x318x136 mm 14.6 kg / 32.2 lbs CE, E-mark, ABYC A-31 HF switch mode 10V, 0.5V 11V, 0.5V 15.5V, 0.5V 14.5V, 0.5V 5% RMS 183A 480 mA 6 W 50 mA 0.6 W 250A 70 mm2 <5% all power factors allowed
Mass Sine 24/800 24020800 24V >50 Ah 230V 50Hz ( 0 .01Hz) 800 W 650 W 1600 W true sine 92% LED display 12.8"x8.7"x4.4" 325x220x111 mm 3.9 kg / 8.6 lbs CE, E-mark, ABYC A-31 HF switch mode 19V, 0.5V 22V, 0.5V 32V, 0.5V 30V, 0.5V 5% RMS 36A 240 mA 5.6 W 35 mA 0.8 W 63A 16 mm2 <5% all power factors allowed
-25C80C, >40C derating -13F176F, >104F derating natural/forced 48 dBA at 1 mtr IP23 natural/forced 48 dBA at 1 mtr IP23
-25C80C, >40C derating -13F176F, >104F derating natural/forced 48 dBA at 1 mtr IP23 natural/forced 48 dBA at 1 mtr IP23
over temperature, over load, short circuit, high battery, low battery yes, using a MasterBus Inverter Interface or AC power analyser internal internal internal internal
Remote control on/off for the Mass Sine sine wave inverter. Battery consumption meter for 2 batteries, 12/24V DC with LCD read-out, remote control for Mass Sine inverter and Mass battery charger or Mass Combi. Integrates the Mass Sine inverter in a MasterBus network in a MasterBus network. Integrates the Mass Sine inverter in a MasterBus network and measures the AC voltage, current and power. The Masterswitch and Systemswitch can be connected to all inverters.
66
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Mass Sine 24/1500 24021500 24V >150 Ah 230V 50Hz ( 0 .01Hz) 1500 W 1200 W 2900 W true sine 92% LED display 13.4"x10.3"x5.1" 340x261x130 mm 8 kg / 17.4 lbs CE, E-mark, ABYC A-31 HF switch mode 19V, 0.5V 22V, 0.5V 32V, 0.5V 30V, 0.5V 5% RMS 68A 200 mA 5 W 25 mA 0.6 W 100A 25 mm2 <5% all power factors allowed
Mass Sine 24/2500 24022500 25022500 24V >200 Ah 230V 50Hz ( 0 .01Hz) 2500 W 2000 W 5000 W true sine 92% LED display 16.5"x12.5"x5.1" 420x318x130 mm 14.6 kg / 32.2 lbs CE, E-mark, ABYC A-31 HF switch mode 19V, 0.5V 22V, 0.5V 33V, 0.5V 31V, 0.5V 5% RMS 115A 250 mA 6 W 25 mA 0.6 W 160A 50 mm2 <5% all power factors allowed
Mass Sine 24/5000 24095100 24V >400 Ah 230V 50Hz ( 0 .01Hz) 5000 W 4000 W 9000 W true sine 92% LED display 18.5"x12.4"x10" 470x315x254 mm 25 kg / 55.1 lbs CE, E-mark, ABYC A-31 HF switch mode 19V, 0.5V 22V, 0.5V 32V, 0.5V 30V, 0.5V 5% RMS 230A 250 mA 6 W n.a. 1x 250A or 2x 125A 2x 70 mm2 <5% all power factors allowed
Mass Sine 24/10kVA 24026000 24V >500 Ah 230V 50Hz ( 0 .01Hz) 10 kW 8 kW 20 kW true sine 92% LED display 2x 460.5x318x143 + 475.5x318x254 mm 44 kg / 97 lbs CE, ABYC A-31 HF switch mode 19V, 0.5V 22V, 0.5V 32V, 0.5V 31V, 0.5V 5% RMS 4x 120A 180 W <10 W, 412 mA 4x 160A 4x 50 mm2 2,5% all power factors allowed
Mass Sine 24/15kVA 24027000 24V >800 Ah 230V 50Hz ( 0 .01Hz) 15 kW 13 kW 30 kW true sine 92% LED display 3x 460.5x318x143 + 475.5x318x254 mm 55 kg / 121.3 lbs CE, ABYC A-31 HF switch mode 19V, 0.5V 22V, 0.5V 32V, 0.5V 31V, 0.5V 5% RMS 6x 120A 180 W <10 W, 412 mA 6x 160A 6x 50 mm2 2,5% all power factors allowed
-25C80C, >40C derating -13F176F, >104F derating natural/forced 48 dBA at 1 mtr IP23 natural/forced 48 dBA at 1 mtr IP23
-25C80C, >40C derating -13F176F, >104F derating natural/forced 48 dBA at 1 mtr IP23 natural/forced 48 dBA at 1 mtr IP23 natural/forced 48 dBA at 1 mtr IP23
over temperature, over load, short circuit, high battery, low battery yes, using a MasterBus Inverter Interface or AC power analyser internal internal internal internal internal
Remote control on/off for the Mass Sine sine wave inverter. Battery consumption meter for 2 batteries, 12/24V DC with LCD read-out, remote control for Mass Sine inverter and Mass battery charger or Mass Combi. Integrates the Mass Sine inverter in a MasterBus network in a MasterBus network. Integrates the Mass Sine inverter in a MasterBus network and measures the AC voltage, current and power. The Masterswitch and Systemswitch can be connected to all inverters.
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/inverters
toll free 800.307.6702 MASTERVOLT | mastervolt.us MARINCO | marinco.com
67
Combined functionality
Power boost from battery when shore power is limited (shore/ generator support). Charging two individual battery terminals. Invert to 230V/50Hz pure sine wave voltage. Supplies 12, 24 or 48 volt onboard power. Multiple distribution and switching systems. Two Combis parallel switched for more power. The Mass Combi meets the ABYC A-31 guideline.
68
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Save space, weight and battery power With its intelligent design including high frequency switch mode technology and an anodized aluminum housing, the Mass Combi is compact, lightweight and efficient. For instance, the 2500 Watt unit weighs only 24.3 lbs. Designed for the marine environment with multiple safety features, the Mass Combi has a very low amp draw when turned on and no load is present decreasing the drain on the batteries. Connection points are within easy reach and external mounting key hole slots allow speedy installation. Customizing a system is easily accomplished through MasterBus (see Mass Combi in a MasterBus System on the next page). Mass Combi inverter/chargers meet global industry standards including CE, ABYC and UL.
Intuitive operation Each Mass Combi can be operated easily and intuitively. The Mass Combi includes LED indication of charging phase and charge current, the 230/120V system load and 12/24 or 48V system, yes/no availability of 120/230V and failure. It features an on/off switch with a charge only position when the boat is in storage. Mastervolt also offers a complete selection of control panels, ranging from the compact 3.5 inch panel called MasterView Easy (picture) to a large 10.4-inch touchscreen panel. This requires a MasterBus Combi Interface, with the exception of the 2500W and 48V models. Not just any battery charger The built-in battery charger uses Mastervolts proven 3-step charging technology to allow easy charging of all battery types, including Lithium Ions. The battery charger supplies a maximum charge current, even with a higher charge voltage, and speeds up the recharging of your batteries. The Mass Combi also functions as DC supply if there is no battery, allowing you, for instance, to use your lighting when your boat is hauled up for winter.
The Mass Combi for extra power If you require more power than the shore can provide, the Mass Combi will take this from the battery. The Mass Combi also ensures that the battery is recharged once consumption drops.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
69
Mass Combi 12/2500-100 Item # General Specifications Sine Wave Inverter Nominal DC voltage Continuous power at 25C/77F, cos phi 1 Surge capability (5 sec, resistive) Parallel use (to double the power) Output voltage ( 5%) Output waveform Efficiency DC consumption at 230V Search mode consumption General Specifications Battery Charger Nominal input voltage Max. charge current (adjustable) Primary AC consumption (full charge) Charge voltage 25C/77F (absorption/float)* Charge characteristic Second charge output, 3-step Temperature sensor battery General Specifications Display/read-out Dimensions, hxwxd Weight Approvals Technical Specifications Max. current first output Max. current shortbreak / inverter output Transfer time Grounding Temperature range (ambient temp.) Cooling Sound level Protection degree Protections MasterBus compatible Options Remote ICC 70405000 Remote APC 70405050 Masterlink/MICC 70403105 MasterView Easy 77010305 50A 35A 10 ms LED display 19.5x12.5x6.1 inch 496x318x156 mm 11 kg / 24.3 lbs CE, ABYC A-31 120V 4565Hz 100A at 14.25V 1700 W 14.5A 14.25/13.25V IUoUo, automatic / 3-step 5A 12V (1015V) 2500 W - 10.9A 5000 W - 21.8A yes 120V 60Hz, 0,05% true sine 90% <9 W 0.5 W 37012505
Mass Combi 12/4000-200 37014005 12V (1015V) 3750 W - 16.5A 7500 W - 32A no yes 120V 60Hz, 0,05% true sine 90% <18 W 1W 120V 4565Hz 200A at 14.25V 3400 W - 29A 14.25/13.25V for gel/AGM/wet/Lithium Ion 2x 5A
Mass Combi 24/2500-60 37022505 24V (2031V) 2500 W - 10.9A 5000 W - 21.8A yes yes 120V 60Hz, 0,05% true sine 93% <9 W 0.5 W 120V 4565Hz 60A at 28.5V 2000 W - 17A 28.5/26.5V 5A
Mass Combi 24/4000-100 37024005 24V (2031V) 3750 W - 16.5A 7500 W - 32A no yes 120V 60Hz, 0,05% true sine 93% <18 W 1W 120V 4565Hz 100A at 28.5V 3500 W - 29A 28.5/26.5V 2x 5A
delivered as standard with 6 metre cable and telejack plug LED display 19.5x12.5x11 inch 496x318x279 mm 21 kg / 46.3 lbs CE, ABYC A-31 50A 35A 10 ms LED display 19.5x12.5x6.1 inch 496x318x156 mm 11 kg / 24.3 lbs CE, ABYC A-31 50A 35A 10 ms LED display 19.5x12.5x11 inch 496x318x279 mm 21 kg / 46.3 lbs CE, ABYC A-31 50A 35A 10 ms
yes, adjustably by DIP switch maintenance free vario fans 48 dBA at 1 mtr IP23 yes** 48 dBA at 1 mtr IP23 yes**
yes, adjustably by DIP switch maintenance free vario fans 48 dBA at 1 mtr IP23 yes** 48 dBA at 1 mtr IP23 yes**
over temperature, over load, short circuit, high battery, low battery
delivered as standard delivered as standard delivered as standard delivered as standard Indication of DC consumption, charge phase, AC present, failure, with on/off/charger only switch & 6 m cable. option option option option Indication of AC consumption, AC voltage, fuse value of the shore/generator connection, with Power Sharing. option option option option Battery consumption metre for 2 batteries, 12/24V DC with LCD read-out, remote control for Mass Sine inverter and Mass battery charger or Mass Combi option** option** option** option** Touch screen panel for reading charge status, current fold-back and/or Power Sharing setting.
MasterBus Combi Interface option** option** option** option** Integrates the Mass Combi in a MasterBus network. 77030475 * The charge characteristic can be set to your requirements. ** In combination with a MasterBus Combi Interface item # 77030475.
For detailed specifications, scale drawings, 3D files, certificates, manuals and 120V models see mastervolt.us/combis
70
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
1 2 3 4 5 6 7 8 9
3 kW generator MasterView Easy Mass Combi Masterswitch Shore connection AGM starter battery MVG gel battery MasterShunt DC Distribution
3 power output for: boiler washing machine 4 5 short break output for: computer socket socket
7 8
9 grounding
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
71
Mass Combi 12/1200-60 Item # General Specifications (sine wave inverter) Nominal DC voltage Continuous power at 25C/77F, cos phi 1 Surge capability (5 sec, resistive) Parallel use (to double the power) Parallel with shore/generator (for more power) Output voltage ( 5%) Output waveform Efficiency DC consumption at 230V Search mode consumption General Specifications (battery charger) Nominal input voltage Max. charge current (adjustable) Primary AC consumption (full charge) Charge voltage 25C/77F (absorption/float)* Charge characteristic Second charge output, 3-step Temperature sensor battery General Specifications Display/read-out Dimensions, hxwxd Weight Approvals Technical Specifications Max. current first output Max. current shortbreak / inverter output Transfer time Grounding Temperature range (ambient temp.) Cooling Sound level Protection degree Protections MasterBus compatible Options Remote ICC 70405000 Remote APC 70405010 Masterlink/MICC 70403105 MasterView Easy 77010305 MasterBus Combi Interface 77030475 50A 25A 10 ms LED display 14.6"x12.5"x5.6" 371x318x143 mm 7.8 kg / 17.2 lbs CE, E-mark, ABYC A-31 12V (1015V) 1200 W - 5.3A 2400 W - 10.5A no yes true sine 90% <9 W 0.5 W 36011205
Mass Combi 12/2000-100 36012005 12V (1015V) 2000 W - 8.7A 4000 W - 17.5A yes yes true sine 90% <9 W 0.5 W
Mass Combi 12/2500-100 36012505 12V (1015V) 2500 W - 10.9A 5000 W - 21.8A yes yes true sine 90% <9 W 0.5 W
Mass Combi 12/4000-200 36014005 12V (1015V) 3750 W - 16.5A 7500 W - 32A no yes true sine 90% <9 W 1W
230V (180265V) 4565Hz 60A at 14.25V 1035 W - 4.5A 14.25/13.25V IUoUo, automatic / 3-step 5A 100A at 14.25V 1656 W - 7.2A 14.25/13.25V 5A 100A at 14.25V 1656 W 7.2A 14.25/13.25V 5A 200A at 14.25V 3312 W - 14.4A 14.25/13.25V 2x 5A
delivered as standard with 6 metre cable and telejack plug LED display 19.5"x12.5"x6.1" 496x318x156 mm 11 kg / 24.3 lbs CE, E-mark, ABYC A-31 50A 25A (35A at 120V) 10 ms LED display 19.5"x12.5"x6.1" 496x318x156 mm 11 kg / 24.3 lbs CE, E-mark, ABYC A-31 50A 25A 10 ms LED display 19.5"x12.5"x11" 496x318x279 mm 21 kg / 46.3 lbs CE, E-mark, ABYC A-31 50A 25A (35A at 120V) 10 ms
yes, adjustably by DIP switch maintenance free vario fans 48 dBA at 1 mtr IP23 yes** 48 dBA at 1 mtr IP23 yes**
yes, adjustably by DIP switch maintenance free vario fans 48 dBA at 1 mtr IP23 yes** IP23 yes**
over temperature, over load, short circuit, high battery, low battery
option delivered as standard option delivered as standard Indication of DC consumption, charge phase, AC present, failure, with on/off/charger only switch... option option option option Indication of AC consumption, AC voltage, fuse value of the shore/generator connection, with... option option option option Battery consumption metre for 2 batteries, 12/24V DC with LCD read-out, remote control for Mass Sine... option** option** option** option** Touch screen panel for reading charge status, current fold-back and/or Power Sharing setting. option** option** Integrates the Mass Combi in a MasterBus network. delivered as standard option**
* The charge characteristic can be set to your requirements ** In combination with a MasterBus Combi Interface Item # 77030475.
72
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Mass Combi 24/1200-35 36021205 24V (2031V) 1200 W - 5.3A 2400 W - 10.5A no yes true sine 92% <9 W 0.5 W
Mass Combi 24/2000-60 36022005 24V (2031V) 2000 W - 8.7A 4000 W - 17.5A yes yes true sine 93% <9 W 0.5 W
Mass Combi 24/2500-60 36022505 24V (2031V) 2500 W - 10.9A 5000 W - 21.8A yes yes true sine 93% <9 W 0.5 W
Mass Combi 24/4000-120 36024005 24V (2031V) 3750 W - 16.5A 7500 W - 32A no yes true sine 93% <9 W 1W
Mass Combi 48/2500-35 36042505 48V (4062V) 2500 W - 10.9A 5000 W - 21.8A yes yes true sine 93% <9 W 0.5 W
Mass Combi 48/5000-70 36045005 48V (4062V) 5000 W - 21.8A 8000 W - 35A no yes true sine 93% <9 W 1W
230V (180265V) 4565Hz 35A at 28.5V 1170 W - 5.1A 28.5/26.5V IUoUo, automatic / 3-step 5A 60A at 28.5V 1965 W - 8.5A 28.5/26.5V 5A 60A at 28.5V 1965 W - 8.5A 28.5/26.5V 5A 120A at 28.5V 3900 W - 17A 28.5/26.5V 2x 5A 35A at 57V 2295 W - 10A 57/53V n.a. 70A at 57V 4590 W - 20A 57/53V n.a.
delivered as standard with 6 metre cable and telejack plug LED display 14.6"x12.5"x5.6" 371x318x143 mm 7.8 kg / 17.2 lbs CE, E-mark, ABYC A-31 50A 25A 10 ms LED display 19.5"x12.5"x6.1" 496x318x156 mm 11 kg / 24.3 lbs CE, E-mark, ABYC A-31 50A 25A (35A at 120V) 10 ms LED display 19.5"x12.5"x6.1" 496x318x156 mm 11 kg / 24.3 lbs CE, E-mark, ABYC A-31 50A 25A 10 ms LED display 19.5"x12.5"x11" 496x318x279 mm 21 kg / 46.3 lbs CE, E-mark, ABYC A-31 50A 25A (35A at 120V) 10 ms LED display 19.5"x12.5"x6.1" 496x318x156 mm 11 kg / 24.3 lbs CE, E-mark, ABYC A-31 50A 25A 10 ms LED display 19.5"x12.5"x11" 496x318x279 mm 21 kg / 46.3 lbs CE, E-mark, ABYC A-31 50A 25A 10 ms
yes, adjustably by DIP switch maintenance free vario fans 48 dBA at 1 mtr IP23 yes** option & 6 metre cable. option Power Sharing. 48 dBA at 1 mtr IP23 yes** delivered as standard option
yes, adjustably by DIP switch maintenance free vario fans 48 dBA at 1 mtr IP23 yes** option option option option** delivered as standard 48 dBA at 1 mtr IP23 yes** delivered as standard option option option** option**
yes, adjustably by DIP switch maintenance free vario fans 48 dBA at 1 mtr IP23 yes** option option option option** delivered as standard 48 dBA at 1 mtr IP23 yes** option option option option** delivered as standard
over temperature, over load, short circuit, high battery, low battery
option option inverter and Mass battery charger or Mass Combi. option** option** option** option**
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/combis
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
73
Masterstrokes No unnecessary heat development due to the use of smart electronics. Continuous output voltage. Easy to install. Please note: Choose the right input/output voltage. Do you require galvanic isolation? Desired capacity.
74
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Programmable via a desktop or laptop PC Remote control the Mac or Magic via your laptop or PC or configure your personal preferences. The device has a communication port and easy installation with a PC-Link and MasterAdjust software. 3-Step battery charger Connected to the 24V main battery, the converter can also be used as an advanced 3-step chargers for 12/24V gel, AGM, wet or Lithium Ion batteries (Mac & Magic models only).
Energy-saving dimmer function Many standard light dimmers convert part of the energy to heat and also lose unnecessary energy. The Mastervolt Mac & Magic converters regulate the power supply efficiently and without excessive heat build-up, up to 250 Watt for optimal safety (multiple Mac or Magic converters can be used for multiple lamps).
Over 90% efficiency Advanced high-frequency technology with modern microprocessors ensures minimum power loss when switching from 24 to 12V and vice versa. If you have many power-consuming devices on-board, the parallel use of several units allows capacities of 40, 60 or more amps.
Solid connections Chrome-plated brass connection block with screw terminal or chrome-plated fast-on for DC in/out.
CLICK
Complete package DC Master All DC Master converters are delivered with mounting bracket, screws and fasteners.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
75
24/12-3A Item # Input Specifications Nominal input voltage Input range Output Specifications Nominal output voltage Maximum power Nominal power Current max. 2 minutes* / continuous DC consumption General Specifications Dimensions, hxwxd Weight Approvals Galvanic isolation Stabilized Connections input/output Temperature range (ambient temp.) Cooling Sound level Protection degree 2.6"x3.4"x2" 67x87x50 mm 225 gr / 0.5 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53 13.6V 82 W 41 W 6A / 3A <10 mA 24V 2032V DC 81400100
24/12-6A 81400200 24V 2032V DC 13.6V 136 W 82 W 10A / 6A <10 mA 3.5"x3.4"x2" 89x87x50 mm 270 gr / 0.6 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53
24/12-12A 81400300 24V 2032V DC 13.6V 245 W 164 W 18A / 12A <10 mA 5"x3.4"x2" 127x87x50 mm 405 gr / 0.9 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53
24/12-24A 81400330 24V 2032V DC 13.6V 408 W 326 W 30A / 24A <10 mA 5"x3.4"x2" 167x87x50 mm 635 gr / 1.4 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53
12/12-3A Item # Input Specifications Nominal input voltage Input range Output Specifications Nominal output voltage Maximum power Nominal power Current max. 2 minutes* / continuous DC consumption General Specifications Dimensions, hxwxd Weight Approvals Galvanic isolation Stabilized Connections input/output Temperature range (ambient temp.) Cooling Sound level Protection degree 3.5"x3.4"x2" 89x87x50 mm 290 gr / 0.6 lbs CE, E-mark yes yes fast-on natural cooling <30 dBA at 1 mtr IP53 13.6V 54 W 41 W 3A / 4A <100 mA 12V 1015.5V DC 81500600
12/12-6A 81500700 12V 1015.5V DC 13.6V 108 W 81 W 8A / 6A <100 mA 8.5"x3.4"x2" 217x87x50 mm 820 gr / 1.8 lbs CE, E-mark yes yes fast-on natural cooling <30 dBA at 1 mtr IP53
24/12-3A 81500100 24V 2032V DC 13.6V 82 W 41 W 6A / 3A <10 mA 3.5"x3.4"x2" 89x87x50 mm 290 gr / 0.6 lbs CE, E-mark yes yes fast-on natural cooling <30 dBA at 1 mtr IP53
24/12-6A 81500200 24V 2032V DC 13.6V 136 W 82 W 10A / 6A <10 mA 5"x3.4"x2" 127x87x50 mm 410 gr / 0.9 lbs CE, E-mark yes yes fast-on natural cooling <30 dBA at 1 mtr IP53
* More power available for two minute intervals, ideal for active marine telephone use. All DC Master converters come with a mounting bracket, screws and fast-ons.
76
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
no picture available yet 24/12-50A 81400350 24V 2032V DC 13.6V 720 W 500 W 60A / 50A <10 mA 11.8"x3"x4.3" 300x76x110 mm 1.2 kg / 2.6 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53 12/24-3A 81400400 12V 1015.5V DC 27.2V 109 W 82 W 4A / 3A <110 mA 3.5"x3.4"x2" 89x87x50 mm 290 gr / 0.6 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53 12/24-7A 81400500 12V 1015.5V DC 27.2V 245 W 191 W 9A / 7A <120 mA 6.6"x3.4"x2" 167x87x50 mm 610 gr / 1.3 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53 48/12-6A 81400600 48V 4062V DC 13.6V 109 W 82 W 8A / 6A <15 mA 3.5"x3.4"x2" 89x87x50 mm 415 gr / 0.9 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53 48/12-9A 81400700 48V 4062V DC 13.6V 132 W 108 W 11A / 9A <15 mA 5"x3.4"x2" 127x87x50 mm 415 gr / 0.9 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53 48/12-20A 81400800 48V 4062V DC 13.6V 326 W 272 W 24A / 20A <15 mA 5"x3.4"x2" 217x87x50 mm 765 gr / 1.7 lbs CE, E-mark no yes fast-on natural cooling <30 dBA at 1 mtr IP53
24/12-12A 81500300 24V 2032V DC 13.6V 245 W 164 W 18A / 12A <10 mA 6.6"x3.4"x2" 167x87x50 mm 590 gr / 1.3 lbs CE, E-mark yes yes fast-on natural cooling <30 dBA at 1 mtr IP53
24/12-24A 81500350 24V 2032V DC 13.6V 408 W 326 W 24A / 30A <10 mA 8.5"x3.4"x2" 217x87x50 mm 850 gr / 1.9 lbs CE, E-mark yes yes fast-on natural cooling <30 dBA at 1 mtr IP53
24/24-3A 81500400 24V 2032V DC 27.2V 109 W 82 W 4A / 3A <25 mA 5"x3.4"x2" 127x87x50 mm 590 gr / 1.3 lbs CE, E-mark yes yes fast-on natural cooling <30 dBA at 1 mtr IP53
24/24-7A 81500500 24V 2032V DC 27.2V 245 W 191 W 9A / 7A <25 mA 7"x3.4"x2" 185x87x50 mm 820 gr / 1.8 lbs CE, E-mark yes yes fast-on natural cooling <30 dBA at 1 mtr IP53
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/dcdc-converters
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
77
Mac 24/12-20 Item # Specifications Input Nominal input voltage Input range Input range, 3-step charge mode Lower input set point Delay lower input set point Specifications Output Factory setting Voltage adjustable* Output voltage dimmer* Stabilized Ripple Power (max./nominal) Max. current Charge current 3-step mode General Specifications Galvanic isolation Voltage limited Efficiency Protected against over load Protected against over temperature Dimmer function Alarm contact Dimensions, hxwxd Weight Approvals Technical Specifications 3-Step charge option DC consumption Connections input/output Temperature range (ambient temp.) Cooling Sound level Protection degree MasterBus compatible Options PC-Link 21730100 MasterView Easy 77010305 MasterBus Serial Interface 77030450 * Adjustable with MasterAdjust software. yes (DIP switch settings) <30 mA no yes yes yes 13.6V DC* 1015V DC 413V DC max. 1% peak peak 300 / 270 W 20A 16A 24V 2032V DC 2432V DC 20V DC* 30 sec.* 81200100
Magic 24/12-20 81300100 24V 1932V DC 2432V DC 20V DC* 30 sec.* 13.6V DC* 1015V DC 413V DC max. 1% peak peak 300 / 300 W 20A 16A yes yes yes yes
Magic 24/24-20 81300200 24V 1932V DC 2432V DC 20V DC* 30 sec.* 27.2V DC* 2028.5V DC 826V DC max. 1% peak peak 580 / 580 W 20A 16A yes yes yes yes
yes, by external momentary switch via fast-on connection, to be activated by DIP-switch setting no 7.5"x5.1"x2.4" 190x130x61 mm 1.0 kg / 2.2 lbs CE yes (fast-on connector) 8.9"x6.1"x3.2" 227x154x81 mm 1.8 kg / 4 lbs CE yes (DIP switch settings) <115 mA yes (fast-on connector) 8.9"x6.1"x3.2" 227x154x81 mm 1.8 kg / 4 lbs CE yes (DIP switch settings) <115 mA
screw terminals, maximum wire size 16 mm2 / AWG5 -25C80C, >40C derating / -13F176F, >104F derating natural cooling <30 dBA at 1 mtr IP21 maintenance free vario fans <48 dBA at 1 mtr IP21 <48 dBA at 1 mtr IP21
yes, by means of MasterBus Serial Interface (Item # 77030450) Interface between Magic converter and PC, in combination with the MasterAdjust software (free to download). The PC-Link can be directly connected to a computer serial port. Touch screen panel for reading status and dimmer function settings. Integrates the Mac & Magic converters in a MasterBus network.
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/dcdc-converters
78
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Magic 12/12-20 81300400 12V 1116V DC 1216V DC 10V DC* 30 sec.* 13.6V DC* 1015V DC 413V DC max. 1% peak peak 300 / 300 W 20A 16A yes yes yes yes
Magic 12/24-10 81300300 12V 1116V DC 1216V DC 10V DC* 30 sec.* 27.2V DC* 2028.5V DC 826V DC max. 1% peak peak 300 / 300 W 10A 8A yes yes yes yes
Magic as power supply The Magic models can be fully used as a stabilised power supply: From 1224V, from 2412V or from 2424V. Inputs and outputs are galvanically isolated.
yes, by external momentary switch via fast-on connection, to be activated by DIP-switch setting yes (fast-on connector) 8.9"x6.1"x3.2" 227x154x81 mm 1.8 kg / 4 lbs CE yes (DIP switch settings) <115 mA yes (fast-on connector) 8.9"x6.1"x3.2" 227x154x81 mm 1.8 kg / 4 lbs CE yes (DIP switch settings) <115 mA
Mac & Magic as battery charger A 12V starter or emergency power battery can be charged as well as maintained by Mac or Magic units. The charging method is identical to the Mass 3-step with voltage levels adjustable by means of MasterBus PC-Link/MasterAdjust software.
screw terminals, maximum wire size 16 mm2 / AWG5 -25C80C, >40C derating / -13F176F, >104F derating maintenance free vario fans <48 dBA at 1 mtr IP21 <48 dBA at 1 mtr IP21
yes, by means of MasterBus Serial Interface (Item # 77030450) Interface between Magic converter and PC, in combination with the MasterAdjust software (free to download). The PC-Link can be directly connected to a computer serial port. Touch screen panel for reading status and dimmer function settings. Integrates the Mac & Magic converters in a MasterBus network.
Mac & Magic as dimmer Light can be dimmed by means of a push button or plus switch, with a maximum load of 250 Watt for the Mac. A second Mac can be installed if there are multiple lamps.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
79
80
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Modern transformer technology: Light, silent, reliable and easy Mastervolts Mass GI offers the latest high-frequency switching technology as well as Soft Start for peak loads when connecting to the shore. Weighing a mere six kilos, LED lights on the casing indicate load and overload. The transformer can be remote controlled via a panel and has the option of automatically starting the generator when there is a shore current overload. Higher capacity via parallel switching Parallel switching of the Mass GI units increases the shore power capacity. Two 16A/3.5 kW units ensures 32A/7 kW, four units give 64A/14 kW. Global solution The IVET-D multi-tap is suitable for 230V/50Hz and 120V/60Hz (American or Caribbean). Install anywhere With its maritime, aluminium casing, this isolation transformer can be fitted in any position on a wall or floor. No rubber mountings are necessary because the unit does not vibrate or hum. The Mass GI also features professional connections with strain relief cable glands.
Practical tips: Determine shore and onboard current: 230V, 120V or both. Determine the capacity. Maximum load with onboard power usage: Amount of amps and kW. Note sizes and weight; the Mass GI is 75% lighter and 60% smaller compared to low frequency transformers. Remember: Detection system for IVET heavy duty automatically supplies onboard system with 230V in case of a 120V/60Hz shore connection (or vice versa). Systemswitch or Masterswitch for integrating shore power, generator and/or inverter. Connects to 12V or 24V system, battery charger or Mass Combi.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
81
Mass GI 3.5 Item # Input Input voltage Input frequency Nominal input current at 230V No load consumption Earth leakage protection Output Output voltage (equal to input) Output frequency (equal to input) Soft Start Switch off behaviour breaker Efficiency General Specifications Power Technology Dimensions, hxwxd Weight Ambient temperature Switch off at Cooling Operating humidity Protection degree MasterBus compatible Optional remote control 77010305 * Up to 4 units parallel (14 kW). 3500 W* high frequency 13.4"x10.3"x5.7" 340x261x144 mm 6 kg / 13.2 lbs 80C / 176F variofan max. 95% IP23 yes yes, MasterView Easy 90255V, 5% 4565Hz yes B-characteristic >93% 90255V 4565Hz 16A 22 W no 88000350
Mass GI 7 88000705 90255V 4565Hz 32A 44 W no 90255V, 5% 4565Hz yes B-characteristic >93% 7000 W high frequency 13.4"x10.3"x9.8" 340x261x250 mm 10 kg / 22 lbs 80C / 176F variofan max. 95% IP23 yes no
IVET-D 16A 3.5 kVA multi tap 86050351 220240V (110120V adjustable) 4565Hz 16A <10 W no 220240V, 5% (110120V adjustable) 4565Hz yes B-characteristic >93% 3500 W torroidal 16"x11.6"x8.7" 407x295x220 mm 23 kg / 50.7 lbs 120C / 248F natural cooling forced cooling >80C / 176F max. 95% IP23 no no
040C, derating with 5% per C (4060C) / 32104F, derating with 5% per F (104140F)
Automatically adjust shore power to the onboard system Mastervolt supplies three automatic switching systems for capacities of 6, 9 and 13 kW that combined with an IVET transformer adjust shore power to the onboard system. As a result a 230V/50Hz system can easily function with an American or Caribbean shore connection. Do ensure that the frequency on board (50 or 60Hz) is the same as the frequency of the shore current.
82
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
IVET 6 85000600 110/220/240V 4565Hz 26A <10 W no 120/220/240V, 5% 4565Hz option n.a. >93% 6000 W E-core 15"x9.5"x8.5" 380x240x215 mm 50 kg / 110.2 lbs n.a. natural cooling max. 95% IP00 no no
IVET 8 85000800 110/220/240V (adjustable) 4565Hz 35A <10 W no 120/220/240V, 5% 4565Hz option n.a. >93% 8000 W E-core 16.9"x11"x8.3" 430x280x210 mm 59 kg / 130 lbs n.a. natural cooling max. 95% IP00 no no
IVET 10 85001000 110/220/240V (adjustable) 4565Hz 44A <10 W no 120/220/240V, 5% 4565Hz option n.a. >93% 10 kW E-core 16.9"x11"x9.5" 430x280x240 mm 75 kg / 165.4 lbs n.a. natural cooling max. 95% IP00 no no
IVET 13 85001300 110/220/240V (adjustable) 4565Hz 57A <10 W no 120/220/240V, 5% 4565Hz option n.a. >93% 13 kW E-core 19.3"x12.6"x9" 490x320x230 mm 90 kg / 198.4 lbs n.a. natural cooling max. 95% IP00 no no
040C, derating with 5% per C (4060C) / 32104F, derating with 5% per F (104140F)
Transfer systems with Soft Start and automatic detection of the input voltage 6 kVA 9 kVA 13 kVA Item # Voltage Power Max. input current Dimensions, hxwxd Weight 55010600 120/230V 6 kW 60A at 120V 30A at 230V 15.7"x11.8"x8.3" 400x300x210 mm 12 kg / 26.5 lbs 55010900 120/230V 9 kW 80A at 120V 40A at 230V 15.7"x11.8"x8.3" 400x300x210 mm 12.5 kg / 27.6 lbs 55011300 120/230V 13 kW 130A at 120V 70A at 230V 15.7"x11.8"x8.3" 400x300x210 mm 13 kg / 28.7 lbs
Soft Start 13 kVA 55003300 230V 2.513 kW n.a. 7.9"x7.1"x4.5" 200x180x115 mm 1.2 kg / 2.6 lbs
Soft Start 22 kVA 55003400 230V 1322 kW n.a. 7.9"x7.1"x4.5" 200x180x115 mm 1.5 kg / 3.3 lbs
For detailed specifications, scale drawings, 3D files, certificates and manuals see mastervolt.us/isolation-transformers
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
83
84
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Store
Batteries ________________________________________________86 AGM Batteries___________________________________________88 Gel Batteries ____________________________________________89 Lithium Ion Batteries _____________________________________91
Mastervolt Exclusive Supplier of Batteries for Camper Emirates Team New Zealand in the Volvo Ocean Race 2011
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
85
Store: Batteries
Reinforced Batteries
All Mastervolt batteries are equipped with shock-proof positive and negative battery plates with rubber separation, while the electrolyte is absorbed in gel or glass fibre (AGM). A high-grade lead/calcium compound guarantees you a constant capacity and minimum self-discharging. Mastervolt has the right battery for every marine application. Mastervolt batteries are: Maintenance-free. Safe; no gas formation. Easy to install. Designed for cyclic use (charge/discharge). Leak-proof. With a two-year warranty. Issues to take into account: Determining the correct battery capacity for your new battery/ batteries is very important. For support and more information see mastervolt.us/batteries. Choosing the right battery charger lengthens the lifespan of your batteries considerably. For more information see mastervolt.us/ chargers. Mastervolts modern 3-step+ charge technology charges your batteries safely and quickly. A control panel is the best way to make the most of your batteries. Go to mastervolt.us/batterymonitor for more information. To choose the right battery, go to the table on the opposite page.
86
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Store: Batteries
Store | Batteries
2
MVG gel semi-traction ++++ +++ ++++ +++ ++++ +++ +++ +++ +++ ++++ +++ ++++ ++++ +++ +++ 2 year ++++ + = inadequate - = poor
3
MVSV 2V gel traction ++++ +++ ++++ ++++ ++++ ++++ ++++ ++++ ++ ++++ ++++ ++++ ++++ ++++ ++++ 7 year ++++
4
MLI Lithium Ion ++++ +++++ +++ +++++ +++++ +++++ ++++ +++++ ++++ ++++ +++++ ++++ ++++ +++ +++++ 2 year ++++
1 AGM battery In AGM batteries, the electrolyte (mixture of water and sulphuric acid) is largely absorbed in glass fibre. This type of battery is entirely maintenance-free and there is no gas formation with normal use. Not requiring any ventilation, these batteries can be installed anywhere. Their construction gives a very fast discharge at very high currents so AGM batteries are ideal for systems that require high currents (for instance when starting an engine). The battery poles can be unscrewed and this type of battery can be combined with every standard battery terminal.
3 Traction batteries This robust gel battery is designed for regular and deep discharging (1000 full cycles), and is ideal for large systems that require intensive use and a very long lifespan.
4 Lithium Ion batteries Lithium ion batteries have a high energy density and are perfect for cyclic applications. They offer savings of up to 70% in volume and weight compared to traditional lead-acid batteries, with three times as many charging cycles (2000 full cycles). Another major benefit of the Mastervolt Li-ion battery is that it is equipped with a Battery Management System (BMS), which automatically compensates for any imbalance between the cells. This guarantees you a constant high capacity and longer battery lifespan.
2 Gel batteries In gel batteries, the electrolyte is absorbed by a gel. This type of battery is entirely maintenance-free and has no gas formation with normal use. As no extra ventilation is required gel batteries can be installed anywhere. They are ideal as service battery and for cyclical use, and can be charged very quickly.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
87
AGM Series
Ideal universal battery. Excellent starter function. Perfect upgrade for wet lead acid batteries. Same initial power surge in an AGM 12/90 Ah as in a 180 Ah wet lead-acid battery. Glass-fibre technology ensures low internal resistance. Use of thicker plates allows deep discharging. Also for cyclic use. Two year warranty
AGM 12/55 Item # Capacity C20* CCA to DIN CCA to SAE Max. outer Dimensions** lxwxh Weight 62000550 55 Ah 300A 480A Nominal voltage 12V
AGM 12/130 62001300 12V 130 Ah 585A 935A 16.1x7x9" 410x177x228 mm 83 lbs / 37.6 kg
AGM 12/160 62001600 12V 160 Ah 630A 1000A 19.1x6.7x9.6" 485x170x245 mm 93 lbs / 42.3 kg
AGM 12/225 62002250 12V 225 Ah 815A 1300A 20.6x9.4x9.5" 522x240x241 mm 140 lbs / 63.5 kg
AGM 12/270 62002700 12V 270 Ah 1000A 1600A 20.6x10.6x9.6" 522x268x243 mm 161 lbs / 73 kg
* C20 = battery capacity at a discharge time of 20 hours, till 1.75V per cell.
AGM-SL 12/115 Item # Nominal voltage Capacity C20* CCA to DIN CCA to SAE Max. outer Dimensions** lxwxh Weight 63001150 12V 115 Ah 545A 910A
AGM-SL 12/200 63001851 12V 200 Ah 750A 1250A Item # Nominal voltage Capacity C20* Max. outer Dimensions** lxwxh Weight
11.6x7.1x11.7 in 11.6x7.1x14.4 in 11.6x7.1x16.9 in 295x180x298 mm 295x180x366 mm 295x180x428 mm 79.3 lbs / 36 kg 107.7 lbs / 48.9 kg 122.7 lbs / 55.7 kg
22x4.3x9.2 in 22x4.3x11 in 22x5x11 in 560x110x233 mm 560x110x280 mm 560x126x280 mm 78 lbs / 35.6 kg 89 lbs / 40.5 kg 119 lbs / 54 kg
* C20 = battery capacity at a discharge time of 20 hours, till 5.25V. **Including terminals and grip handles
* C20 = battery capacity at a discharge time of 20 hours, till 1.75V per cell. **Including terminals and grip handles
88
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Store | Batteries
MVG 12/25 Item # Nominal voltage Capacity C20* CCA to DIN CCA to SAE Max. outer Dimensions** lxwxh Weight 64000250 12V 25 Ah 110A 175A 6.6x6.9x5 in 167x176x126 mm 21.2 lbs / 9.6 kg
MVG 12/55 64000550 12V 55 Ah 230A 380A 10.3x5.4x9 in 261x136x230 mm 41.9 lbs / 19 kg
MVG 12/85 64000850 12V 85 Ah 270A 450A 13x6.7x9.3 in 330x171x236 mm 71.9 lbs / 32.6 kg
MVG 12/120 64001200 12V 120 Ah 450A 760A 20.2x7.4x8.8 in 513x189x223 mm 90.4 lbs / 41 kg
MVG 12/140 64001400 12V 140 Ah 540A 920A 20.2x8.8x8.8 in 513x223x223 mm 108 lbs / 49 kg
MVG 12/200 64002000 12V 200 Ah 630A 1100A 20.4x10.8x9.4 in 518x274x238 mm 154.3 lbs / 70 kg
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
89
MVSV 280 Item # Nominal voltage Capacity C10* Max. outer Dimensions** lxwxh Weight 68000280 2V 280 Ah 4.9"x8.2"x15.8" 125x207x401 mm 22 kg / 48.5 lbs
* C10 = battery capacity at a discharge time of 10 hours, till 1.80V per cell.
MVSV 1250 Item # Nominal voltage Capacity C10* Max. outer Dimensions** lxwxh Weight 68001250 2V 1250 Ah 8.3"x9.2"x27.3" 211x234x693 mm 82 kg / 180.8 lbs
* C10 = battery capacity at a discharge time of 10 hours, till 1.80V per cell.
90
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Store | Batteries
2009
* Battery capacity at a discharge time of 1 till 20 hours. **Including terminals and grip handles
Extensive testing of the Mastervolt Li-ion battery by Team Emirates resulted in Mastervolt becoming their official supplier.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
91
92
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage
Battery Switches _________________________________________94 Battery Distribution Clusters _____________________________ 100 Battery Distribution Panels ______________________________ 104 Traditional Battery Switches _____________________________ 109 Battery Management Panels ____________________________ 112 Battery Isolators & Dynaplates __________________________ 113 Fuses & Fuse Holders __________________________________ 115 Circuit Breakers _______________________________________ 119 DC / AC Circuit Breaker Panels __________________________ 124 LabelsCircuit Breaker Panels ___________________________ 133 Switch Panels & Switches _______________________________ 139 Battery Distribution Accessories _________________________ 145 Transfer Systems ______________________________________ 150 MasterBus ____________________________________________ 154 CZone ______________________________________________ 164 MonitoringDC / AC / Tank / Gas _________________________ 181 Wire & Cable __________________________________________ 193 Terminals & Lugs ______________________________________ 201 Heat Shrink Tubing _____________________________________ 209 Cable Ties & Wire Management _________________________ 211 Kits, Tools & Testers ____________________________________ 217
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
93
701
701S
700
Panel-Mounted Switches
The panel mount range of battery switches are designed specifically for panel mount applications. This range gives a very compact, versatile solution. Compact, lightweight Removable key on 701-PM Countersunk recesses for surface mount application Standard 2-1/16" (52 mm) hole cut out (same as standard gauge hole) Inside: captive inserts for 3/16" (4.8 mm) nuts; full access for cables - no restrictions Standard BEP interchange label system (see 136) Item # 701-PM 701S-PM OEM # 701B-PM 701S-B-PM Specs Same as 701 Same as 701S
701S-PM
701-PM
Mounting Plates
Single recessed. Supplied with all the mounting hardware and come in a matching grey finish. For 701 Item # BSP-1 LxW 3.75"x3.75" / 95x95 mm As shown in Contour Connect panels panel
94
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
720
720-DP
721
BEP Marine Battery Switch Test Procedures (UL 1107) Continuous (1 hour), intermittent (5 minutes) & Cranking (engine starting 10 seconds). The test is to determine the maximum current the switch can handle for the stated time, without the rear terminals exceeding 100C (212F) above the ambient temperature. The continuous and intermittent ratings are tested at 110% of specified ratings. All BEP switches are tested Independently to this specification by a 3rd party laboratory
Specifications - All recessed or surface mount, tin-plated copper studs & nuts, ignition-protected in Item # OEM # LxWxH 700B 2.7"x2.7"x4.3" 700 701B 2.75"x2.75"x3" 701 701S-B 2.75"x2.75"x3" 701S 720B 4"x4"x3.5" 720 720-DP 720-DP/B 4"x4"x3.5" 721B 4"x4"x3.5" 721 Rating (A DC) mm Voltage LxWxH Continuous Intermittent Cranking (V DC) 68x68x110 mm 275 455 1250 48 69x69x75 mm 275 455 1250 48 69x69x75 mm 200 300 1000 48 102x102x90 mm 600 800 2500 48 102x102x90 mm 400 525 1500 48 102x102x90 mm 350 500 1500 48 Operation On/Off On/Off 1-2-Both-Off On/Off On/Off 2 poles 1-2-both-Off Stud size Studs x (in/mm) 2 x (3/8" / 10 mm) 2 x (3/8" / 10 mm) 3 x (5/16" / 8 mm) 2 x (1/2" / 12 mm) 4 x (1/2" / 12 mm) 3 x (3/8" / 10 mm)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
95
include internal optical sensors providing even more operational functionality to this innovative master switch.
Optical sensor benefits (720-MDO only) Can be used to switch in positive or negative lines Low stand by current draw (7mA) (zero if aux control switch used. See instruction sheet) Main contacts isolated from control circuit allowing operation via another battery source
Remote operation Battery switch can be mounted alongside battery, reducing cable lengths and cable sizes to starter motor. (Large cost saving in copper cables) Reduced installation labor, due to shorter battery cable runs Manual override option to meet CE requirements Power Draw: Switch off: 12mA. Switch on: 15mA, switch operating 120mA for 3 seconds @ 12V nominal LED status identification for remote control switch Same capacities/specifications and mounting options as standard BEP battery switches Uses same interchangeable labeling system as BEP battery switches (136)
720-MDO
701-MD
Specifications - All recessed or surface mount, tin-plated copper studs & nuts, ignition-protected Item # 701-MD 720-MDO in LxWxH 2.7"x2.7"x4" 4"x4"x4.33" mm LxWxH 68x68x101 mm 102x102x110 mm Rating (A DC) Voltage Continuous Intermittent Cranking (V DC) 275 455 1250 9.532 500 700 2500 9.532 Stud size Function Studs x (in/mm) On/Off 2 x (3/8" / 10 mm) On/Off 2 x (1/2" / 12 mm)
96
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
720-MDO-EP
80-701-0018-00
Engages Disengages (V DC) (V DC) 13.7 12.213.00 13.7 12.213.00 27.4 24.426.00 27.4 24.426.00 Emergency Parallel Only Emergency Parallel Only
701
80-724-0006-00
OUTPUT INPUT
(ON)/OFF SWITCH
701
IT IS IMPERATIVE THAT THE NEGATIVE (BLACK) FOR THE MD/MDVS IS TAKEN FROM THE SAME BATTERY THAT IT IS ISOLATING. FAILURE TO DO THIS WILL CAUSE THE UNIT TO WORK ERRATICALLY. ONLY ONE NEGATIVE MUST BE SUPPLIED TO EACH UNIT FOR CORRECT OPERATION.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
97
Item # 710-140A
OEM # 710-140A-B
Volts (V) 12 24
Wiring diagrams indicative of installation only, for full instructions see the BEP website: bepmarine.com
98
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Charge Mate
An auxiliary onboard power supply is increasingly common. As a second battery can prevent the main battery from depleting and being unable to start, this seems like a safe and reliable solution. The second battery, however, also has to be charged regularly. Mastervolt has the solution: The Charge Mate connects both batteries with a voltage relay while charging, and keeps them isolated at other times. The Charge Mate is especially practical for small systems.
Item # Battery voltage Continuous power Inrush current (250ms) Switch on voltage Switch on delay Switch off voltage Switch off delay Ambient temperature Dimensions, hxwxd Weight Protection degree Number of modes Power consumption
Charge Mate 1202 83301202 12/24V 120A 2000A 13...15V (12V) 26...30V (24V) 5 sec < 12.75V (12V) < 25.5V (24V) no -4065C 3"x1.8"x1.8" 76x46x46 mm 0.28 lbs / 0.125 kg IP21 n.a. switch open: < 1mA at 12/24V DC
Charge Mate 2505 83302502 12/24V 500A 2000A 13...15V (12V) 26...30V (24V) 30 sec < 12.25... > 15V (12V) < 25.5...> 30V (24V) 3 minutes -4060C 3.5x3.1x3.3" 90x80x85 mm 1.4 lbs / 0.65 kg IP21 on, off, auto, start assist switch open: < 1mA at 12/24V DC
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
99
100
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
716-SQ-140A-DVSR
716-H-140A-DVSR
Dimension guide Clusters are made from uniformly square switches, each side 2.7" (69 mm)
Twin inboard or outboard Twin outboard Twin inboard Triple outboard VSR Charging Current: 150A
Battery (banks) Item # 2 714-140A-DVSR 715-H 715-V 716-SQ-140A-DVSR 716-H-140A-DVSR 2 715-S 3 717-140A-DVSR 3 718-140A-DVSR 4 719-140A-DVSR Battery Switch Rating: 275A
in LxWx3 5.4"x2.75" 8.1"x2.75" 2.75"x8.1" 5.4"x5.4" 10.85"x2.75" 8.1"x2.75" 5.4"x8.1" 8.1"x5.4" 8.1"x 8.1"
mm LxWx75 138x69 207x69 69x207 138x138 276x69 210x69 138x207 207x138 207x207
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
101
102
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
103
80-700-0051-00 Description Single engine remote Twin engine remote Triple engine remote Item # 80-700-0050-00 80-700-0051-00 80-700-0052-00
Triple Engine
Single Engine
80-700-0047-00
80-700-0048-00
80-700-0053-00
80-716-0014-00
80-716-0015-00
80-716-0016-00
104
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
105
Dimensions for Contour Connect Panels Item # CC-801 CC-810 CC-802 CC-803N 80-700-0054-00 80-700-0055-00 *Single hole only. LxWxH in Module 6.5"x4.2"x2.2" 9.2"x4.2"x2.2" 6.5"x8.3"x2.2" 9.2"x8.3"x2.2" 9.2"x4.2"x2.2" 9.2"x8.3"x2.2" Cut-out 5.75"x3.4" 8.5"x3.4" 5.75x7.5"* 8.5"x3.4"* 8.5"x3.4"* 8.5"x3.4"* LxWxH mm Module 166x106x55 mm 233x106x55 mm 166x212x55 mm 223x212x55 mm 223x106x55 mm 223x212x55 mm Cut-out 146x86 mm 213x86 mm 126x192 mm* 213x86 mm* 213x86 mm* 213x86 mm*
Blanking Plate
The CC-BLANK will cover an unused hole in CC-1 and CC-2. Attached from the rear of the panel, it allows for expanding with other options at a later date. Item # CC-BLANK
DC Outlet
The CC-12VRC allows a DC outlet socket to be placed within the Contour Connect panels. It will fit into the CC-1, CC-2 or CC-5 panels. Item # CC-12VRC
CC-810
CC-811PR
CC-811T
CC-801
106
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
8 Way CB Panel
8 Way CB Panel, 4x Toggle, 4x Push Reset 2 x 10A, and 2 x 15A toggle circuit breakers and 2x 10A and 2 x15A push reset circuit breakers Item # CC-807T-PR
5 Way CB Panel
1x Heavy-Duty CB, 1x Toggle, 3x Push Reset Equipped to cover essential circuits requirements (bilge, pumps etc) 50A CB for DC mains or treatment systems 135A 185 Series CB for anchor windlass Compliments the other modules for either single or dual engine installations Item # CC-804
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
107
The Contour Connect Kit set Panels are designed for applications where the OEM or panel builder wishes to construct a custom system. Theyre supplied as empty panels with all necessary mounting hardware, including one CC-joiner. CC-1 CC-5
Flexible Links
Flexible links are supplied pre-connected with spare links for different orientations (horizontal or vertical) of Contour Connect panels. Must be ordered separately when ordering CC Kitset panels. 709-300/BD Link (mm x mm, g) 6x120 mm, 10g 6x150 mm, 10g 6x210 mm, 10g 6x300 mm, 10g 25x150 mm, 4g 25x250 mm, 4g 25x300 mm, 4g 25x150 mm, 4g 25x250 mm, 4g 25x300 mm, 4g Terminals (mm, mm) 6, 10 mm 6, 10 mm 6, 10 mm 6, 10 mm 6, 10 mm 6, 10 mm 6, 10 mm 2 x 10 mm 2 x 10 mm 2 x 10 mm Item # LD-6R-120-CE LD-6R-150-BD LD-6R-210-BD LD-6R-300-BD 709-150/BD 709-250/BD 709-300/BD 709-150/DD 709-250/DD 709-300/DD
Solid Links
708-42.5 Solid terminal links supplied pre-connected with spare links for different orientations (horizontal or vertical) of Contour Connect panels. Must be ordered separately when ordering CC Kitset panels. Item # 708-42.5 708-70.0 708-107
CC-2 Module
Will house the following components: CLB series (push reset) Carling circuit breakers (page 120). Toggle Magnetic Hydraulic Carling circuit breakers (page 119).
708-42.5
Application For horizontal linking of battery switches in the same panel For horizontal linking of battery switches studs between 2 separate panels For vertical linking of battery switches between panels
CC-3 Module
Will house the following components: CLB series (push reset) Carling circuit breakers (page 120). Toggle Magnetic Hydraulic Carling circuit breakers (page 119).
Link Bar
NCB-CC Link bar between circuit breakers. Same bar fits toggle or push reset CBs. Bar can be cut to bring multiple feeds to circuit breakers. Supplied with 800 Series panels or CC-Kitset panel. Item # NCB-CC
Wave Strips
CC-HDBM The Contour Connect panels are supplied standard. Wave strips can be ordered separately and are supplied in pairs of top and bottom strips. Available in single, double, and triple lengths. Item # CC-3WS/CH
108
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Continuous amps: 230 Momentary amps: 345 Item # 2111A OEM # 2111A-B
Continuous amps: 230 Momentary amps: 345 Item # 2110A OEM # 2110A-B
Continuous amps: 230 Momentary amps: 345 Item # 2112A OEM # 2112A-B
Continuous amps: 230 Momentary amps: 345 Item # 2100 OEM # 2100-B
Continuous amps: 230 Momentary amps: 345 Item # 2101 OEM # 2101-B
Continuous amps: 230 Momentary amps: 345 Item # 2102 OEM # 2102-B OEM # 2102-3-B black
Continuous amps: 450 Momentary amps: 800 Item # 2303A OEM # 2303A-B *(black knob)
Continuous amps: 600 Momentary amps: 1000 Item # 2304A OEM # 2304A-B *(black knob)
Continuous amps: 360 Momentary amps: 600 Item # 2300A OEM # 2300A-B *(black knob)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
109
As more and more electronics and electrical accessories are added to your boat (autopilot, refrigeration, etc.) the use of multi-batteries becomes a necessity. Guest components allow you to set up the system (from simple to complex) for your boats application. The following diagrams are for use in identifiying and designing the right system for your boating needs. Detailed installation schematics are available. Request Guest form I-21681.
STARTER
STARTER
1 12 VOLT BATTERY 1 2
ENGINE
ENGINE
12 VOLT BATTERY
ALT
ALT
ON/OFF SWITCH
2 12 VOLT BATTERY
Single battery Installation: To shut off all power at source. Recommended installation by approved authorities.
Two battery with out isolator Installation: To select a starter battery and ship service battery. Manually isolates each battery, parallels both batteries for emergency start, master disconnect, manually selects batteries for charging.
STARTER
1
STARTER
ENGINE
12 VOLT BATTERY
ENGINE
12 VOLT BATTERY
ALT 2
1 2
2
1 2
12 VOLT BATTERY
12 VOLT BATTERY
ISOLATOR
ISOLATOR
Two battery with isolator Installation: Isolator automatically selects lower charged battery to be charged first. Full battery can't discharge to drained battery. Dedicated system, no flexibility, no emergency parallel or disconnect function.
Two battery with emergency parallel Installation: An isolator automatically isolates each battery, lower charged battery will automatically be charged first. Two different size batteries can be used, larger for ship services, smaller for engine cranking. Switch selects usage, master disconnect, emergency parallel function.
110
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
STARTER
ENGINE
1 2
ENGINE
12 VOLT BATTERY
ALT
SELECTOR SW
1 3 2
ISOLATOR
ISOLATOR
One battery selector switch, one On/Off selector switch automatic battery isolation and automatically charges three batteries Installation: Use for sailboats and trawlers. Third battery isolated from other ship circuits. All batteries being automatically charged while running through isolator. To be used for refrigeration or other heavy load devices. Isolator protects other batteries. Switch selector usage: 1. Master disconnect 2. Emergency parallel function
Adding automatic battery charger/converters to system Installation: At dockside multi-bank charger built in isolator which will automatically charge lower battery.
STARTER
ENGINE
1 2
SELECTOR SW
1 3 2
ISOLATOR
Three batteries, one battery selector switch, one On/Off or selector switch, two alternators, one isolator Installation: Isolator separates both alternators so both alternators will charge simultaneously. Automatically charges lowest battery first. All batteries can be used for start, third battery, ships source.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
111
800-MS1 The 800-MS1 panel is designed for power or sail boats between 1012m (32.9-39.5 ft) with single engines. 260x351x75 mm (10.25"x13.8"x2.9")
800-MS2 The 800-MS2 panel is designed for power boats between 1012 m (32.939.5 ft) with twin engines. 281x463x75 mm (11.1"x18.25"x2.9") 800-MS3 The 800-MS3 panel is designed for power boats between 12 16 m (39.5 52.5 ft) with larger diesels. 380x463x95 mm (15"x18.25"x3.75")
Circuit Breakers
800-MS4 The 800-MS4 panel is designed for sail boats up to 14 m (46 ft) and power boats up to 10 m (32.9 ft) with single engine. 160x239x75 mm (6.3"x9.4"x2.9") For treatment systems, davit winches and sub-mains. Item # CBL-50A-SP 50A Item # CBL-75A-SP 75A Item # CBL-100A-SP 100A
112
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
BI Battery Isolators
Mastervolts BI battery isolators are based on conventional diode technology. The diode voltage drop (ca. 0.6V) can be compensated for by adapting the output current of the connected charger. Mastervolt battery chargers and Alpha Pro alternator regulators come as standard with automatic compensation for voltage drops.
Item # Max. output charger Max. output alternator Compensation diode Dimensions, hxwxd Weight # of battery banks
BI 702-S 83007021 25/50A 70A yes 6.2"x5.5"x3.2" 157x140x80 mm 1.3 lbs / 0.58 kg 2
BI 1202-S 83012021 80A 120A yes 8.2"x5.5"x3.2" 207x140x80 mm 2.65 lbs / 1.2 kg 2
BI 1203-S 83012031 80A 120A yes 8.2"x5.5"x3.2" 207x140x80 mm 2.9 lbs / 1.3 kg 3
Battery Mate
The Battery Mate is compatible with any type of alternator/battery charger, in both existing and new systems. As the voltage loss between the alternator and battery is negligible, the Battery Mate performs far better than conventional battery isolators. This ensures fast and complete charging of your batteries without having to make additional adjustments to the alternator.
Item # Max. output charger Max. output alternator Dimensions, hxwxd Weight # of battery banks
Battery Mate IG 1602 83116025 120A 160A 8.2"x5.5"x3.2" 207x140x80 mm 2.2 lbs / 1 kg 2
Battery Mate IG 1603 83116035 120A 160A 8.2"x5.5"x3.2" 207x140x80 mm 2.2 lbs / 1 kg 3
Battery Mate IG 2503 83125035 200A 250A 8.2"x5.5"x3.2" 207x140x80 mm 2.2 lbs / 1 kg 3
Battery Isolators
Optimized heat sink design for maximum performance Minimized voltage drop across isolation barrier using Schottky type diodes Each output individually capable of carrying the full alternator load Fixed cable posts for secure connections Fully potted, marine grade construction Waterproof components for harsh environment performance - year after year NOTE: If used on a 24V system, boat must be equipped with 24V DC alternator
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
113
Battery Watch
The Battery Watch is an essential element of any well-equipped battery system, offering you a 600-gram electronic watchdog that ensures a much longer lifespan for your batteries. The unit switches off loads when batteries are nearly empty, to keep your batteries in optimum condition. LED lights provide a clear read out and the undervoltage can be set using DIP switches. Battery Watch 83200150 150A 8-32V DC 9-12V DC 18-24V DC 6.2"x5.5"x3.2" 157x140x80 mm 1.3 lbs / 0.6 kg
Item # Max. load Input voltage Switch off under voltage 12V Switch off under voltage 24V Dimensions, lxwxh Weight
114
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage: Fuses
Marine Fuses
Fast-acting, corrosion resistant fuses open quickly to protect circuits from overloads and short-circuits. Time-delayed to allow temporary, harmless in-rush currents to pass but open on sustained overloads and short-circuits. Each fuse tested twice to ensure highest quality.
ATM Fuses
Diameter: 5/16" (7.9 mm) Length: 7/16" (11 mm) Maximum voltage: 32V DC Rating (A) 5 10 15 20 30 Kit 1 of ea Qty/ Pkg 2 2 2 2 2 5 Item # 603905 603910 603915 603920 603930 601110
ATO/ATC Fuses
Diameter: 13/16" (21 mm) Length: 3/4" (19 mm) Maximum voltage: 32V DC Rating (A) 3 5 7.5 10 15 20 25 30 Kit 530 Qty/ Pkg 2 2 2 2 2 2 2 2 6 Item # 604003 604005 604007 604010 604015 604020 604025 604030 601114
AGC Fuses
Diameter: 1/4" (6.4 mm) Length: 1-1/4" (32 mm) UL 248-14 Rating Qty/ (A) Pkg 250V AC max 1/2 5 1 5 1.5 5 2 5 2.5 5 3 5 4 5 5 5 7 5 7.5 5 8 5 10 5 32V AC max 15 5 20 5 25 5 30 5 Kits 530 5 130 41 Item # 601005 601010 601015 601020 601025 601030 601040 601050 601070 601075 601080 601100 601150 601200 601250 601300 601300 601300
MDL Fuses
Slow Blow Diameter: 1/4" (6.4 mm) Length: 1-1/4" (32 mm) UL 248-18 Rating Qty/ (A) Pkg 250V AC max 3 2 5 2 6.25 2 7.5 2 10 2 125V AC max 15 2 20 2 25 2 30 2 Item # 602030 602050 602062 602075 602100 602150 602200 602250 602300
GMA Fuses
Diameter: 3/16" (5 mm) Length: 13/16" (20 mm) Maximum voltage: 125V AC UL 248-14 Rating (A) 1 2 3 5 7 10 15 Qty/ Pkg 3 3 3 3 3 3 3 Item # 605010 605020 605030 605050 605070 605100 605150
AGA Fuses
Diameter: 1/4" (6.4 mm) Length: 5/8" (16 mm) Maximum voltage: 32V AC UL 248-14 Rating (A) 20 30 Qty/ Pkg 5 5 Item # 604200 604300
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
115
MasterShunt Fuse
T-fuse 500A / 160V DC, current limiting capability 50 kA Diameter: 1.62" (41 mm) Length: 3.06" (77 mm) Rating Qty/ (A) Pkg 500 1 Item # 77049000
Maxi-Blade Fuses
Fuses available: 30-80A Interrupt capacity: 1000A DC Maximum voltage: 32V DC Rating (A) 30 40 50 60 70 80 Qty/ Pkg 1 1 1 1 1 1 Item # BFHD-30A/DSP BFHD-40A/DSP BFHD-50A/DSP BFHD-60A/DSP BFHD-70A/DSP BFHD-80A/DSP OEM # BFHD-30A BFHD-40A BFHD-50A BFHD-60A BFHD-70A BFHD-80A
116
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
ATC-6W
80-712-0039-00
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
117
Fuse Holders
Figure Letter A Description AWG Wire Item # Panel Mount 607010 Panel Mount Fuse Holder 607011 Cap for 607010 Crimp-On 1218 (38 mm2) AGC & MDL 30 607012 Waterproof In-Line 1218 (38 mm2) AGC & MDL 30 607013 AGU 30 Waterproof In-Line 10 (5 mm2) 607014 AGC & MDL 20 Waterproof In-Line 12 (3 mm2) 607015 AGC & MDL 30 Heavy-duty In-Line 12 (3 mm2) 607016 ATC 30 In-Line 12 3 mm2) 607017 ATO/ATC 30 Waterproof In-Line 12 (3 mm2) 607019 ATM 30 Waterproof In-Line 12 (3 mm2) 607020 ATM 15 Waterproof In-Line 16 (1 mm2) 607021 In-Line ATO/ATC 15 607022 ATO/ATC 30 In-Line 10 (5 mm2) 607023 With weather resistant cap and tinned copper wire for corrosion resistance Rating (Max Fuse Style Amps) AGC & MDL 15
B C D E F G H I J K L
IJ
KL
Item # 607006
118
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
CBS-50A-SP-IG
CBS-50A-DP
Single pole CBS-5A-SP CBS-10A-SP CBS-15A-SP CBS-20A-SP CBS-25A-SP CBS-30A-SP CBS-40A-SP CBS-50A-SP-IG
Triple pole CBS-50A-TP / 50 D / Pole trip coil CBS-15A-DP-TC230 CBS-20A-DP-TC230 CBS-30A-DP-TC230 CBS-50A-DP-TC230
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
119
184150P-01-1
185100F-01-1
OEM # 185050P-01-1 185070P-01-1 185080P-01-1 185100P-01-1 185135P-01-1 185150P-01-1 185050F-01-1 185080F-01-1 185100F-01-1 185150F-01-1 185030F-01-1 185040F-01-1 185040P-01-1 185060P-01-1 185120P-01-1 CLB-BOOT
CLB-20
120
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
121
RCD Panels
We supply two Residual Current Device (RCD) ratings (16 & 32A). Due to the difference in style of the RCDs, these panels are made to be mounted separately from the main ACpanel. Item # 900-RCD-16A 900-RCD-1X16-32A 900-RCD-2X16A 900-RCD-2X32A 900-RCD-32A Rating (A) 16 32 16x2 32x2 16x1, + 32x1 HxWx2.5" 4.5"x5" 4.5"x5" 4.5"x5" 4.5"x5" 4.5x5" HxWx65 mm 115x127 mm 115x127 mm 115x127 mm 115x127 mm 115x127 mm
900-RCD-16A
900-RCD-2X16A
CB Options
Item # RCD16A30MA RCD32A30MA RCD63A30MA MCB16A MCB32A MCB63A 124001000 Rating (A) 16 32 63 16 32 63 16 Type Residual CB Overload Residual CB Overload Residual CB Overload Miniature CB Miniature CB Miniature CB Shore Fix 30 mA
For installations in Australia and New Zealand to comply with AS/NZ3004 an approved double pole mains circuit breaker must be mounted upstream of the BEP Control Panel in the form of a RCD or MCB. The MCB-3WENC is an enclosure with IP65 rating. The enclosure and CB is ordered separately. The Shore Fix is already assembled, no additional item parts need to be ordered.
122
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Panel Plugs
5/8" (15.9 mm) Black Used in electrical control panels Pkg qty 2
Line-to-Line Jumper
Used in terminal blocks with 5/8" (15.9 mm) between holes 100 amps total capacity Pkg qty 5 Item # 553021
Item # 553020
Mounting Screws
Black Nylon 5-32"x 5/16" (4x7.9 mm) Used in mounting circuit breakers to electrical control panel
Handle Lock
Image shows handlelock as used in all our battery management panels for essential CBs to prevent accidental or unintended actuation of essential circuits CBs from either the on or off position. (ordered separately) Item # 121-710-1101/1
Item # 553041
Modular Brackets
Black Item # 554000 Item # 554001 end middle
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
123
DC No Meters
Red systems on LED 12V Marine grade powder coated aluminium ABYC standard voltage indication Green LED backlit labels Stylish clip on contour fascia Label sets and buss bar supplied with panels; for additional labels see page 133134
901V
902NMV
900-DC
901H
904NMV
902NMH
# of Circuits Direction 4 square 8 horizontal vertical 12 horizontal vertical 16 square horizontal 24 square vertical 32 horizontal vertical 36 square
in HxWx2.5 4.5"x5" 4.5"x9.75" 7.9"x5" 4.5"x13.9" 11.25"x5" 7.9"x9.75" 4.5"x18.25" 7.9"x13.9" 11.25"x9.75" 7.9"x18.25" 14.6"x9.75" 11.25"x13.9"
mm HxWx65 115x127 115x239 200x127 115x351 285x127 200x239 115x463 200x351 285x239 200x463 370x239 285x351
Neg 30 Bus 6 way 6 way 6 way 6 way 6 way 12 way 12 way 1 12 way 1 12 way 1 24 way 1 24 way 1 24 way
Item # 900-DC 901H 901V 902NMH 902NMV 904NM 904NMH 905NM 905NMV 906NMH 906NMV NC36NM
Cutout size - 3/8" (10 mm) inside all external edges For more information on circuit breaker panels go to bepmarine.com
124
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
904NM
905NMV
NC36NM
906NMV
Resistors
905NM For changing 12V panels to 24V backlighting # of Circuits 4 way 8 way 12 way 16 way 20 way 24 way 28 way 32 way 36 way 44 way 56 way 906NMH Item # RES-4WAY RES-8WAY RES-12WAY RES-16WAY RES-20WAY RES-24WAY RES-28WAY RES-32WAY RES-36WAY RES-44WAY RES-56WAY
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
125
DC Analog/Digital Meters
Ammeters available in other scales (page 186). All panels are available with either Analog or Digital meters Label set and bus bar supplied with panel; for additional label sets see page 133134
900-AM
901V-DCSM
902V-DCSM
M28-DCSM # of Circuits 4 8 12 16 20 24 32 48 mm HxWx65 200x127 295x127 200x239 380x127 295x239 200x351 295x351 380x239 295x463 455x239 380x463
M28-DCSM in HxWx2.5 7.9x5 11.6x5 7.9x9.75 15x5 11.6x9.75 7.9x9.75 11.6x13.9 15x9.75 11.6x18.25 18x9.75 15x18.25 Label Sheet 1 1 1 1 12 13 13 13 14 14 15
902-AM Digital Item # 900V-DCSM 901V-DCSM 902-DCSM 902V-DCSM 904-DCSM 903-DCSM 905-DCSM 905V-DCSM 906-DCSM 906V-DCSM Analog Item # 900-AM 901V-AM 902-AM 902V-AM 904-AM 903-AM 905-AM 905V-AM 906-AM 906V-AM 907-AM
Direction vertical vertical square vertical vertical horizontal square vertical horizontal vertical square
30 Neg Bus 6 way 6 way 6 way 6 way 12 way 1 12 way 1 12 way 1 12 way 1 24 way 1 12 way 2 2 x 24 way
All analog panels supplied with one shunt, extra shunts ordered separately. Digital panels supplied with 450A-50mV shunt. Cutout size - 10 mm (3/8") inside all external edges All panels available in 12 or 24V configuration. All part numbers shown are 12V backlighting. If 24V is required, please specify when ordering by adding 24V to part number. For more information on circuit breaker panels go to bepmarine.com
126
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
903-DCSM
907-AM
905-AM
906-AM
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
127
Cruiser Series
12V / 24V Mimic panel for quick reference of systems in operation Blank space for addition of extra meter Digital or analog readouts
NC32Y-DCSM # of Circuits 32 36 in HxWx2.5 15x13.9 15x13.9 mm HxWx65 380x351 380x351 Label Sheet 14, 6 14, 6
NC36L-DCSM CBs - Single Pole 5 10 15 20 25 7 11 11 1 1 8 12 12 2 1 Digital Item # NC32Y-DCSM NC36L-DCSM Analog Item # NC32Y-AM NC36L-AM
30 1 1
All analog panels supplied with one shunt, extra shunts ordered separately. Digital panels supplied with 450A 50mV shunt. Cutout size 3/8" (10 mm) inside all external edges All panels available in 12 or 24V configuration. If 24V is required, please specify when ordering by adding 24V to part number.
DP PANEL
128
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Millennium Series
12V / 24V Compact sizing Battery monitoring using BEP multifunction meter (voltage on 3 battery banks, charge, discharge amps and amp-hours remaining on main battery bank
M28-DCSM
M44-DCSM
M56-DCSM
M44H-DCSM
M32-DCSM
# of Circuits 28 32 44 56
30 2 1 2 2 2
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
129
No Meters
Ideal for AC shore power installations and on board inverter installations.
900-ACM2W
900-AC1
900-ACCH
900-ACM6W
in Volts HxWx2.5 230 7.9"x5" 110 4.5"x9.75" 230 4.5"x5" 110 4.5"x5" 230 7.9"x5" 110 7.9"x5" 230 7.9"x5" 110 7.9"x5"
CBs CBs Double Pole Label Single Pole Sheet 5 10 15 20 25 30 20 25 30 50 80 Neg Bus 5 2 2 2 IS-6MM-2 5 2 2 2 IS-6MM-2 5 2 1 IS-6MM-2 5 2 1 IS-6MM-2 5 2 3 1 1 IS-6MM-2 5 3 2 1 1 IS-6MM-2 5 2 IS-6MM-2 5 2 IS-6MM-2
130
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Analog/Digital Meters
All available in 110V/60Hz or 230V/50Hz. All supplied with tranducers Reverse polarity indicator Double pole mains input CBs with side lockout Digital meter shows volts, amps and frequency LED wired to indicate live panel with mains breaker either on or off AC source selector ensures no cross over between AC inputs (ship or shore power) AC voltage/frequency label to comply with ABYC Standards
900-ACM2-AM
900-ACM6V-AM
900-AC2V-ACSM 900-AC4-ACSM
900-AC3-ACSM
in Volts HxWx2.5 Analog 230 7.9"x5"x2.5" 110 7.9"x5"x2.5" 230 11.6"x5"x2.5" 110 11.6"x5"x2.5" 230 7.9"x9.75"x2.5" 110 7.9"x9.75"x2.5" 230 15"x5"x2.5" 110 15"x5"x2.5" 230 7.9"x13.9"x2.5" 110 7.9x13.9x2.5" Digital 230 7.9"x9.75"x2.5" 110 7.9"x9.75"x2.5" 230 15"x5"x2.5" 110 15"x5"x2.5" 230 7.9"x13.9"x2.5" 110 7.9x13.9x2.5" 230 7.9x13.9x2.5" 110 7.9x13.9x2.5" mm HxWxL 200x127x65 mm 200x127x65 mm 295x127x65 mm 295x127x65 mm 200x239x65 mm 200x239x65 mm 380x127x65 mm 380x127x65 mm 200x351x65 mm 200x351x65 mm 200x239x65 mm 200x239x65 mm 380x127x65 mm 380x127x65 mm 200x351x65 mm 200x351x65 mm 200x351x65 mm 200x351x65 mm
900-AC2H-AM
CBs CBs Double Pole Label Single Pole Sheet 5 10 15 20 25 30 20 25 30 50 80 Neg Bus 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 2 2 3 3 2 3 2 4 3 3 2 3 2 4 3 5 5 2 3 3 3 3 3 3 5 4 3 3 3 3 5 4 7 8 1 1 1 2 1 2 1 3 1 2 1 2 1 3 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 IS-6MM-2 IS-6MM-2 IS-6MM-2 IS-6MM-2 2x6 way 2x6 way 2x6 way 2x6 way 2x12 way 2x12 way 2x6 way 2x6 way 2x6 way 2x6 way 2x12 way 2x12 way 2x6 way 2x6 way
Item # 900-ACM2-AM 900-ACM2-AM-110 900-ACM6V-AM 900-ACM6V-AM-110 900-AC2H-AM 900-AC2H-AM-110 900-AC2V-AM 900-AC2V-AM-110 900-AC3-AM 900-AC3-AM-110 900-AC2H-ACSM 900-AC2H-ACSM-110 900-AC2V-ACSM 900-AC2V-ACSM-110 900-AC3-ACSM 900-AC3-ASCM-110 900-AC4-ACSM 900-AC4-ACSM-110
1 1 1 1 1 1 1 1 1 1 1 1
1 1 1
1 1 1 1 1
Cutout size 3/8" (10 mm) inside all external edges. All panels available in 12 or 24V backlighting configuration.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
131
Panel Configurator
The BEP Panel Configurator is a software program designed for do-it-yourself creation and modification of standard circuit breaker panels. The user friendly software is available to both account and non-account holders. Designed for the creation and modification of standard panels, the software provides the end user prompt turn around for panel requirements. Additionally, the built-in communication tool allows for customer created drawings to be transferred with ease to BEP customer service for quotation. The use of the software greatly streamlines the entire panel production process reducing design and modification time, decreasing correspondence and cutting lead time. To learn more and to download the software, go to bepmarine.com.
Cover Description 1 column 8-12 CBs + meter 2 column 8-12 CBs + meter 1 column 8-12 CBs 2 column 8-12 CBs 1 column 8-12 CBs + meter 2 column 8-12 CBs + meter
BC-PM1
BC-FM1
BC-FM2
BC-PM2
132
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
ACCESSORIES
12V OUTLETS
AFT LIGHTS
AC MAINS
AC MAINS
SET-1N
Accessories Anchor Light Auto Pilot Bilge Pump Cabin Lights Cabin Lights Cockpit Lights Compass Lights DC Outlets Depthsounder Freezer Freshwater Pump GPS Instruments LPG Control Mast Light Navigation Lights Saltwater Pump Shower Drain Pump Spare Spotlight Spreader Light Steaming Light Stereo Trim Tabs VHF Winch Wiper
SET-2N
Bait Tank Pump Bilge Pump Aft Bilge Pump Forward Bilge Pump Mid Bilge Pump Port Bilge Pump Starboard Blower Boarding Light Cabin Lights Aft Cabin Lights Fwd Cabin Lights Mid Cabin Lights Port Cabin Lights Starboard Deck Wash Pump Electric Toilet Engine Room Lights Fridge Horn Nav Lts Port Nav Lights Starboard Panel Lights Radar Saloon Lights SSB Start Stern Light Stop Tri Light
SET-3N
12V Outlets 24V Outlets Aft Deck Light Bilge Auto Man. Bow Lights Docking Lights Emergency Parallel Engine Alarm Engine Blowers Extraction Fan Flood Lights Fore Deck Light Galley Lt Generator Lights Holding Tank Pump House Batteries Lazerette Light Port Radio Battery Search Light Starboard Start Batteries Step Light Strobe Light Toilet Lt Weather Fax Windex Light Window Washers
SET-4N
Aft Lights Bedroom/Converter Davit Winch Engine Alternator Fire System Fish Finder Fishing Light Galley/Bath House Alternator Intercom Load Locker Light Mid Wiper Mid Lights Mizzen Spreader Light Plotter Port Wiper Preheat Sole Light Heater Fans Starboard Wiper Sub Main Sump Pump Tank Room Lights Toilet Pump Towing Light TV/Stereo Walvac
SET-5N
AC Mains AC Outlets AC Outlets Air Conditioning Battery Charger Cook Top Dishwasher Dive Compressor Dryer Frequency Genset Heater Hotwater Cylinder Ice Maker Inverter Inverter Outlets Microwave Oven Refrigeration Reverse Polarity Ships Power Shore Power Trash Compactor TV Video Washing Machine Waste Master Water Maker
SET-6N
AC Mains Accessories Anchor Wash Automatic Autopilot Auxiliary Bilge Auto Manual Bilge Lights Boom Furl Bridge Lights Burglar Alarm Cabin Fan CB Radio Cell Phone Computer DC Mains Fuel Transfer Galley Fan Hatch Controls Hydraulics Loud Hailer Macerator Manual Night Lights Pelmet Lights Solar Panel Stove TV Antenna
ANCHOR LIGHT
BOILER/HEATER
AIR COMPRESSOR
12-12V REDUCER
SET-7N
Aft Peak Light Deck Flood Lights Fwd Deck Flood Lights Aft Deck Lights Deck Lights Port Deck Lights Starboard Deck Lights Forward Deck Lights Aft Fishing Lights Fishing Lights White Fishing Lights Red Fishing Lights Green Fish Room Lights Fish Room Pump Fore Deck Light Focsle Light Mast Flood Lights Fwd Mast Flood Lights Aft Net Recorder Not Under Command NUC Lights Plotter Port Flood Lights Shower Lights Stbd Flood Lights Toilet Fan Toilet Light Winch Flood Lights
SET-8N
Anchor Light Baragraph Power Cabin Fans Cabin Fans Fwd Cabin Fans Aft Courtesy Lts Courtesy Lts Fwd Courtesy Lts Mid Courtesy Lts Aft Diesel Heater Fire System Fuel Pump Hailer Lectrasan Lectrasan Fwd Lectrasan Stbd Port Engine Controls Port Ignition Sat Com Shower Light Saloon Lights Spare Spare Stabilizer Stbd Engine Controls Stbd Ignition Toilet Light Waste Treatment
SET-9N
Boiler / Heater Bow Thruster DC/DC Converter Deck Lights Forward Deck Lights Aft Deck Lights Mid Deck Lights Upper Defroster Galley Lights Grey Water Pump Guest State Lights Head Pump 1 Head Pump 2 Master State Lights Nav Lights Oil Pump Pilot House Lights Saloon Lights Search Light Spare Spare Stereo Trim Tab Control V-Berth Lights VHF Lower VHF Upper Wash Down Pump Windlass
SET-10N
Air Compressor Air Con Galley Air Con Guest Room Air Con Master State Air Con Pilot House Air Con Salon Air Con Saloon Air Con State Room Air Con V-Berth Air Conditioning Air Conditioning 1 Air Conditioning 2 Air Conditioning 3 Central Vacuum Charger Generator Charger House Charger Inverter Compactor Engine Room Fans Hot Circ Pump Ice Maker Lower Ice Maker Upper Outlets Engine Room Outlets External Outlets Galley Outlets Lower Deck Outlets Upper Deck Water Heater
SET-12N
24-12V Reducer Aerator Ballast Aft Ballast Control Ballast Fwd Black Tank Aft Black Tank Fwd Black Water Pump Boom Light Bridge Lights Bridge Supply Dining Lights Fire Alarm Flow Alarm Interior Lights Luff Light Modem Nav Area Fan Outlets Aft Outlets Fwd Outlets Mid Outlets Port Outlets Stbd Port Engine Stbd Engine Step Lights Strobe Riding Light
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
133
210KHz TX
AC OUTLETS AFT
24 HOUR CIRCUITS
27 MEG
SET-13N
Aft Bilge Alarm Bilge Alarm Bilge Alarm Test Bilge Auto Bilge Lights Bilge Manual Bilge Pump Auto/ Manual Fwd Bilge Alarm High Water Alarm Mid Bilge Alarm Port Aft Bilge Alarm Port Aft Bilge Auto Port Aft Bilge Manual Port Fwd Bilge Alarm Port Fwd Bilge Auto Port Fwd Bilge Manual Port Mid Bilge Alarm Port Mid Bilge Auto Port Mid Bilge Manual Stbd Aft Bilge Alarm Stbd Aft Bilge Auto Stbd Aft Bilge Manual Stbd Fwd Bilge Alarm Stbd Fwd Bilge Auto Stbd Fwd Bilge Manual Stbd Mid Bilge Alarm Stbd Mid Bilge Auto Stbd Mid Bilge Manual
SET-14N
210KHz TX 33KHz TX Aft Hold Light Cockpit Freezer Engine Controls Fridge/Freezer Fire Pump Fluxgate Compass Flybridge Freezer Fuel Gauge Fuel Transfer Port Fuel Transfer Stbd Fwd Hold Light Gantry Lights Holding Tank Port Holding Tank Stbd Masthead Light Pilot Light Red Pilot Light White Port Fuel Filter Rudder Indicator Stbd Fuel Filter Steering Toilet Aft Toilet Fwd Towing Light Amber Towing Light White Tuna Tubes
SET-15N
12v Outlet Flybridge Arch Lights Bilge Pump Clutch Cabin Heater Compass Dry Head Pump Demister Engine Clutch Pump Flybridge Hatch Flybridge Wipers Freezer Clutch Fwd Stateroom Lights Greywater Pump 1 Greywater Pump 2 Guest Cabin Stereo Inmarsat Instrument Lights Instruments Flybridge Instruments Pilothouse Master Head Lights Nav Area Lights Overhead Lights Overhead Saloon Lights Saloon Wipers Security System Underfloor Lights 24v DC Mains Bow Bilge High Water
SET-16N
AC Outlets Aft AC Outlets Aft Cabin AC Outlets Cockpit AC Outlets Deck AC Outlets Fwd AC Outlets Fwd Cabin AC Outlets Galley AC Outlets Guest Cabin AC Outlets Mid AC Outlets Port AC Outlets Salon AC Outlets Saloon AC Outlets Staterooms AC Outlets Stbd AC Outlets Wheelhouse Aircon Aft Aircon Aft Deck Aircon Cabin Aircon Fwd Aircon Fwd Deck Aircon Helm Aircon Pump Aircon Port Aircon Stbd Airhandler Fwd Stateroom Airhandler Mstr Stateroom Airhandler Pilothouse Airhandler Saloon
SET-17N
24 Hour Circuits Aft Bilge Pump Auto / Man Aft Head Alarm Mute Depth / Speed Electronics Engine Alarm Fans Fwd Bilge Pump Auto / Man Fwd Head Galley / Head Vent Galley Fridge Gas Stove Gauges Head Pump Level Indicator Lights Mid Bilge Pump Auto / Man Nav & Inst Lights Oil Pressure Pt Engine Pt Engine Start / Stop Stbd Engine Stbd Engine Start / Stop Sum Log Synchronizer Water Temp Windshield
SET-18N
27 Meg Aft Holding Tank Aft Water Heater Cabin Outlets Cockpit Fridge DC Mains 1 DC Mains 2 Dehumidifier DVD Engine Blower Engine Room Outlets Entertainment Flybridge Main FWD Holding Tank FWD Water Heater Galley Gas Solenoid Generator GFCI Outlet Hatch Lifter Helm Main Hour Meter Laundry LPG/Cooktop Navigation Range TV /DVD UHF
BOILER/HEATER
CABINE AVANT
AUXILIARE 1
SET-19N
12V Battery Charger 24hr Bilge Pump 24V Battery Charger 12V Battery Charger Bilge Pump Port Fwd Bilge Pump Port Mid Bilge Pump Stbd Aft Bilge Pump Stbd Fwd Bilge Pump Stbd Mid Boarding Platform Bulwark Lights Bunk Lights Cable Master Desalinator Dishwasher Electric Windows Engine Controls Macerator Oil Pump Pitch Control Port Air Con Port Engine Sonar Storeroom Lights Spa Stbd Air Con Stbd Engine TV
SET-20N
12V Aux Horn Aft Fridge Alternator Anchor Winch Bathroom Fan Bathroom Outlets Bridge Supply Docking Lights Engine Room Bilge Alarm Fax Fish Finder Holding Tank Gauge Icemaker Inverter/Charger Lake Water Master Head RCD Reset Salon Lights Shaver Outlets Sounder Speed Sum Log Toilet Port Toilet Stbd TV lift Wind Instruments
SET-22N
Alarms CCTV Cockpit Fridge Communications Control Max 2.0 Deck Lights Earth Leakage Lights Emergency Parallel Engine Room Main Equipment Room Flybridge Lights Fresh Water Pump Port Fresh Water Pump Stbd Genset Start Genset Stop Grill Head/Galley Vent HF Radio Ignition Start Mid Hold Lights Radio Light Radios Refrigerator Reverse Polarity Test UHF Radio VHF Radio Wheelhouse Lights Wine Cooler
SET-23N
Air Con Flybridge Air Con Fwd Air Con Port Air Con Stbd Berth Lights Blower Cabin Lights Main Cooling Pump 1 Cooling Pump 2 Discharge Discharge Discharge Discharge Emergency Lights Gallery Fridge Helm Lights Macerator Master Cabin Lights Port Engine Controls Port Engine Controls Port Engine Controls Quartz Lights Stbd Engine Controls Stbd Engine Controls Stbd Engine Controls Stereo Memory Storage Bin Pump Waterblaster
SET-FRENCH
Cabine Avant Cabine Babord Cabine Tribord Dessalinisateur Divers ECL Interieur Essuie-Glace Feu De Hune Feu De Mouillage Feu De Pont Feux De Navigation Flaps Trim Tabs GPS Groupe DEau Guindeau Instruments Pilote Automatique Pompe De Cale Prise 12V Refrigerateur Salle De Bain Salle Machine Sondeur Stereo Table A Carte Timonerie Ventilateur De Cale VHF
SET-FRENCH 2
Auxiliaire 1 Auxiliaire 2 Avertisseur Cabin 2 Cabin 3 Cabin I Centrale Nav Chauffage Chauffe-Eau Confort Congelateur Divers Eclairage Babord Eclairage Carre Eclairage Nacelle Eclairage Tribord Electronique Feu Tricolore Hi-Fi Micro-Ondes Pompe Babord Pompe De Lavage Pompe Douche Pompe Tribord Radar Spots Toilettes Winch
134
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
CSP6
ANCHOR LIGHT
CSP6
ACCESSORIES
900-6WP
NAVIGATION LIGHTS
CMP-6WP
FRESHWATER PUMP
SET-2SP
Anchor Light Bilge Auto Man Boom Light Cabin Light Cockpit Lights Compass Light Deck Lights Depth Sounder E/R Blower Freezer Hot Tub Light Hot Tub Pump Instruments Locker Lights Nav Lights Port Nav Lights Port wiper Shower Drain Pump Spare 1 Spare 2 Spare 3 Stbd Nav Lights Stbd Wiper Steaming Light Stern Light Sumlog Transom Lights Tri Light
SET-1SP/F
<Mouillage Navigation> Accessories Accessories Aerateur Appliques De Cockpit Appliques Interieures Avertisseur Essuie-Glace 1 Essuie-Glace 2 Essuie-Glace 3 Feu De Mouillage Feu De Navigation Frigo GPS Groupe DEau Instruments Lecteurs De Cartes Pilote Automatique Pompe Cale <Auto Manuel> Pompe De Cale Pompe De Lavage Pompe De Vidange Prises De Courant Radio Sondeur Spots Ventilateur Winch
SET- LBL-WP
Accessories Aerator Anchor Lights Autopilot Bait Tank Pump Bilge Pump Blower Cabin Lights Cockpit Lights DC Outlets Deck Wash Depth Sounder Freshwater Pump Fridge GPS Horn Inst. Lights Instruments Log Navigation lights Radar Spare Spot Lights Stereo Stern Light Trim Tabs VHF Wiper
SET- LBL-CMP
Accessories Aerator Anchor Lights Autopilot Bait Tank Pump Bilge Pump Blower Cabin Lights Cockpit Lights DC Outlets Deck Wash Depth Sounder Freshwater Pump Fridge GPS Horn Inst. Lights Instruments Log Navigation lights Radar Spare Spot Lights Stereo Stern Light Trim Tabs VHF Wiper
800-MS1-4
24 HOUR LIGHTS
800-MS1-4
24V HOUSE VOLTMETER FEED
706 - 707
WINCH
SET-MSP3
24 Hour Lights Bow Bilge Pump Bow bilge Override Bow Thruster Cathodic Protection Charts/Sounder Cockpit Main CO Detector Cockpit Fridge Electronics Main Electric Controls Electric Head Genset Battery Charger Hatch Lifter Helm Main Head Macerator Port Battery Charger Port Engine Blower Port Controls Saloon Mains Stbd Controls Stereo Stereo Amplifier Stbd Battery Charger Stbd Engine Blower Wiper Mid Wiper Port Wiper Stbd Accessories Controls
SET-MSP4
24V House Voltmeter Feed Bilge Alarm Bilge Pump 24 hr Bilge Pump Aft High Water Bilge Pump Fwd High Water Bilge Pump Mid High Water Bilge Pumps Bilge Pumps Main Flybridge 12V Mains Flybridge 24V Mains Genset Blower High Water Alarm House Battery Charger House Battery Meter House Main Lower 12V Mains Lower 24V Mains Port Aft Bilge Pump Port Batter Meter Port Fwd Bilge Pump Port Mid Bilge Pump Shower Sump Stbd Aft Bilge Pump Stbd Battery Meter Stbd Fwd Bilge Pump Stbd Mid Bilge Pump Toilet Twin Disk Twin Disk Port Twin Disk Stbd
toll free 800.307.6702
SET-714
Anchor Winch Bilge Pump Aft Bilge Pump Fwd Bilge Pump Mid Bilge Pump Port Bilge Pump Starb Bow Thruster Davit Winch DC Mains 1 DC Mains 2 Halyard Winch Head 1 Head 2 Holding Tank Inverter Memory Circuits Security System Sheet Winch Spare Waste Treatment 1 Waste Treatment 2
NOTE: The complete range of BEP labels are listed in a quick reference table on our website: bepmarine.com
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
135
ELECTRONICS
CATHODIC PROTECTION
ENGINE CONTROLS ENGINE CONTROLS PORT ENGINE CONTROLS STBD ENGINE ROOM LIGHTS
CO DETECTOR
SET-CC-1 labels are supplied standard with any 800 series module containing toggle or push reset circuit breakers.
DAVIT
DC MAIN
DC OUTLETS
FIRE SYSTEM
LECTRASAN
STEREO
FRIDGE
LIGHTS
7
FUEL TRANSFER PUMP PORT BATTERY CHARGER
STEREO MEMORY
SUMP PUMP
SET-715
HIGH WATER
SPARE
TOILET
SPARE
TRIM TABS
SET-715 contains the 3 most commonly requested labels out of set 713 without the need to purchase a full label set.
WINCH
DAVIT
LECTRASAN
DC MAINS
PUMPS
DECK WINCH
SALOON MAINS
SET-CC-A labels are supplied standard with any 800 series module containing the heavy-duty Busman circuit breaker.
DOCKING WINCH
TOILET
FLYBRIDGE MAINS
WINCH
136
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
HT
LTS ST NAV BD
WIPER MID
ACCESSORIES AERATOR ANCHOR LT BAIT TANK BILGE PUMP AUTO B/P MAN BLOWER CABIN LIGHTS COCKPIT LTS DC OUTLETS DECK WASH DN WINCH UP ELECTRONICS ENGROOM LTS FLOOD LIGHTS
FW PUMP FRIDGE GPS HORN INST. LIGHTS INSTRUMENTS NAV LIGHTS RADIO SW PUMP SPOT LIGHTS UP PORT DN UP STBD DN WIPER
B/PUMP PORT B/PUMP STBD B/PUMP FWD B/PUMP MID B/PUMP AFT B/PUMP ENG RM COMPASS LT DECK LTS STEAMING LT NAV LTS PT NAV LTS STBD STEP LTS STERN LT WIPER PT WIPER MID
WIPER STBD WASHERS FREEZER H/TANK PUMP SUMP PUMP LOCKER LTS PANEL LTS TRI LT BOW LTS SHOWER LT SHOWER PUMP SPARE SPARE
LBL-MICSYM SET-1002
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
137
5A 5A 10A 15A
Circle your selections: AC Voltage: 12V Backlighting: Yes Meters: ACSM Digital: (page 181) Meter Position: 1 Anlg Volts DC: Anlg Amps DC: Anlg Volts AC: Anlg Amps AC: 8-16 0- 50 0-150 0-60
12V
24V
110V
230V
600-VM3 3
600-TG 4 1 1 1 1
600-SOM
2 2 2 2
3 3 3 3
4 4 4 4
If the panel involves a total custom layout, as described above, a specific Item # will be applied to that panel and quoted accordingly. If the design is unable to be achieved we will notify the customer. Alternatively a customer may request a standard panel with circuit breakers laid out to their requirements with labels factory fitted. This involves a personalized layout charge with the following part numbers applying, eg: 901V is ordered as NPF-901V. 902A-12V-12V is ordered as NPF-902A-12V-12V When ordering personalized panels see our label selection that starts on page 133. We can also do specific label sets, priced per-job.
METER POSITION 2
METER POSITION 3
METER POSITION 4
CONTROL
CONTROL
CONTROL
CONTROL
138
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Switches 4 6 5
CMP-4WP
CMP-6WP
CMP-5WPS
Waterproof Series
Compact panel size Sprayproof inline fuse holders with fuses included Waterproof power receptacles (16A) in five and three way models Waterproof to IP56 Switches rated at 20A DC LxWxH is 3.75"x4.25"x2.9" (95x107x75 mm) Panel supplied with label LBL-WP
Switches Color 3 black white 4 black white 5 black white 6 black white
900-4WP
900-6WPW
900-5WP
Spare parts for above panels and panels on page 141 Item # SW-32111 SW-32113 SW-32114 SW-32115 SW-32120 SW-32123 SW-M331 12VPG Type Switch Switch Switch Switch Switch Switch Boot Plug Operation on/off on/on on/off/on (on)off/ momentary (on)off(on) momentary on/off/on double pole Splash proof cover 16A
toll free 800.307.6702 MASTERVOLT | mastervolt.us
WAFH-14
MARINCO | marinco.com
139
Contour Generation ll
The Contour Generation II Spray Proof Range offers unique styling using the latest techniques in injection molding. The switch tray is molded plastic with a rubber gasket and seal molded into the plastic. The cover is molded in a clear plastic with a rubber over-mold allowing the flexibility to operate the switches through the front of the panel while providing a clear window for label backlighting. The contour wave strip is interchangeable allowing for custom colors for OEM applications. Standard color supplied is black panel with charcoal strip. G2 can be mounted vertically or horizontally and is available in 2, 4 and 6 way configurations. A joiner (CG2-JB) is available for multiple panel installations. Supplied complete with on/off switches, these can be interchanged with a variety of different switch options. Replaceable clip-on contour wave (customized colors available for OEMs) Mounting screws covered by switch cover Backlit LEDs CG2-2W Flexible overshot cover allows for easy switch operation Ribbed gasket provides watertight seal with switch cover Molded gasket on panel base creates watertight seal against mounting surface Unique design allows labels to be read whether mounted vertically or horizontally. Switches rated at 16A DC Panel supplied standard with label SET-G2-1 (labels SET-G2-2 ordered separately, page 137)
CG2-4W
CG2-JB
Switches 2 2 4 4 6 6 2 2 4 4 6 6
Color Black Black Black Black Black Black White White White White White White
Fuses No 1 No 2 No 3 No 1 No 2 No 3
Label Sheet SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1 SET-G2-1
Item # CG2-2W CG2-2W-F CG2-4W CG2-4W-F CG2-6W CG2-6W-F CG2-2W-W CG2-2W-F-W CG2-4W-W CG2-4W-F-W CG2-6W-W CG2-6W-F-W
SW-CG1 Spare Switches for Contour Generation II Item # SW-CG1 SW-CG2 SW-CG3 SW-CG4 SW-CG5 Switch type On/Off On/Off Momentary On/Off/On Momentary On/Off/ Momentary On On/On
Available upon request: Different custom color combinations for Contour strip and rubber over-mold.
140
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Micro Series
Green LED backlit labels; red when on Full range of text or graphic labels available; mix n match labels and panels to suit Switches rated 20A DC 3.4"x2.3"x1.2" (86x58x28 mm) Waterproof to IP56 Label see LBL-MIC included; additional label sets available (page 137)
900-BA Bilge alarm and bilge pump control panel includes: 1 on/off/on switch for auto manual control; 1 warning light and alarm for high water level alarm. (Float switch ordered separately Item # SB1-FS)
Fuses No 3 No
PTC No No 6 CSP6
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
141
1000-6W
1000-VM-12V Voltmeter
1000-AM50 Ammeter
SW-RVS2 ON/OFF
Description 10A Ammeter (internal shunt) 20A Ammeter (internal shunt) 50A Ammeter (external shunt, supplied) 12 Volt Systems 24 Volt Systems DC Systems Monitor AC Systems Monitor
16mm (.6")
40mm (1.6")
108mm (4.25")
108mm (4.25")
142
MASTERVOLT | mastervolt.us
60mm (2.4")
MARINCO | marinco.com
Replacement and/or different Operational Switch Description On/On (On/Off) On/Off/On On/Off Spring-loaded in on position Item # SW-6064B3P SW-6064C3P SW-6064D3P
UL 1077 Recognized Certified for prolonged submersion under pressure (front panel sealing) and UL Ignition Protected. Certified to IP66/IP68. Withstands extreme temperatures from -40C to + 85C. Endurance: 150,000 cycles minimum. Rating: 20A at 12V, 10A at 250V AC, 15A at 125V AC without Light Description Single Pole Single Throw Function on-off (on)-off Single Pole Double Throw on-off-on (on)-off-(on) Double Pole Single Throw on-off on-on Double Pole Double Throw on-off-on (on)-off-(on) with Light Description Single Pole Single Throw Function on-off (on)-off Single Pole Double Throw (on)-off-on on-off-on (on)-off-(on) Double Pole Single Throw on-off Double Pole Double Throw on-off-on (on)-off-(on) (on) = Momentary
toll free 800.307.6702 MASTERVOLT | mastervolt.us MARINCO | marinco.com
143
UL 1077 Recognized Function on-off (on)-off (on)-off-(on) Item # 556010 556022 556028
Mounting Hole
UL 1077 Recognized Function on-off (on)-off (on)-off-on on-off-on (on)-off-(on) on-off-on Item # 555010 555022 555025 555026 555028 555033
Terminal Type
Mounting Hole
UL 1077
144
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Bus Bars
Now with easy-fit covers to ABYC standards, with polarity ID 5/32" (4 mm) stainless steel screws with shakeproof washers 2 x 1/4" (6 mm) input studs Tin-plated, brass-insulated mounting bases with recessed mounting holes to avoid accidental shorts on aluminum surfaces Supplied standard with all BEP AC & DC control panels Display pack versions supplied with cover
Covers
Flame-resistant flexible plastic Color-coded for polarity Unique push-on fit Supplied standard with bus bars when ordered in display packs (for bulk packaging ordered separately)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
145
703-300A
Distribution Bus
Allows multiple terminations for heavy-duty negative or positive connections. Modular sizing with Contour Lock housing allows easy grouping and meets ABYC standards for exposed terminals. Item # 703-300A
703-500A
Distribution Bus
Designed to take loads from Heavy-duty Starter Circuits. Taller cover allows for more bulky cables and lugs. Item # 703-300A Use the 708-64.5 link (page 148 for 708 link bar reference chart) for optional expansion on either the 703-300A or the 703-500A.
146
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
48.1mm (1 7/8)
IS-6MM-1
IS-6MM-2
IS-10MM-1
35.8mm (1 7/16) 9.2mm (3/8)
IS-10MM-1R
48.1mm (1 7/8)
32mm (1 1/4)
44mm (1 3/4)
29mm (1 1/8)
48.1mm (1 7/8)
32mm (1 1/4)
IS-10MM-2
IS-10MM-2/L
35.8mm (1 7/16) 9.2mm (3/8)
ISC-10R
ISC-6-2
IS-10MM-8MM Designed for Yamaha engine installations where the positive cable is supplied with a 3/8" (10mm) lug and the negative cable is supplied with an 5/16" (8mm) lug.
31mm (1 1/4)
35.8mm (1 7/16) 9.2mm (3/8) 32mm (1 1/4) 18mm (11/16) 44mm (1 3/4)
9.6mm (3/8)
44mm (1 3/4) 23.61mm (15/16) 36mm (1 7/16) 23.61mm (15/16) 36mm (1 7/16)
Studs
9.6mm (3/8)
(1 1/4) Item # OEM # Stud Size Polarity 9.6mm (3/8) Single Studs IS-6MM-1R 1/4" / 6 mm Positive IS-6MM-1R/DSP* IS-6MM-1 1/4" / 6 mm Negative IS-6MM-1/DSP* IS-8MM-1R 5/16" / 8 mm Positive IS-8MM-1R/DSP* IS-8MM-1 5/16" / 8 mm Negative 23.61mm IS-8MM-1/DSP* (15/16) IS-10MM-1R 3/8" / 10 mm Positive IS-10MM-1R/DSP* 36mm IS-10MM-1 3/8" / 10 mm Negative (1 7/16) IS-10MM-1/DSP* Dual Studs IS-10MM-2 2 x [3/8" / 10 mm] IS-10MM-2/DSP* IS-10MM-2/L 2 x [3/8" / 10 mm] linked IS-10MM-2/L/DSP* IS-10MM-8MM 1 x [3/8" / 10 mm], 1 x [5/16" / 8 mm] IS-10MM-8MM/DSP* IS-6MM-2 2 x [1/4" / 6 mm] IS-6MM-2/DSP* *Item #'s come with cover, OEM #'s do not.
31mm
23.61mm Reducing Sleeve (15/16) For 836mm studs, supplied in mm (1 7/16) display packs. Order separately.
Terminal Blocks
Ideal for isolated connections up to 30A. Suitable for connecting tails from AC and DC panels. Base material: Phenolic; Current rating 30A; Max. voltage rating: 300V AC/DC; Screw size: 0.25" (6.3 mm) Item # TB-118-6P Item # TB-118-10P 6 connections 10 connections
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
147
Distribution Stud
The Contour Distribution Stud allows terminating of heavy-duty cables for one or more connections. Contour Lock housing has removable side plates which allows for connections from all sides.
708-42.5
708-62.0
Terminal Links
The 708 links are designed for space saving interconnections of terminals when battery distribution modules are linked together. Four standard solid links are available for interconnection of the 701 battery switch with other Battery Distribution products and two larger links which are intended for the heavy-duty battery switch. Item # 708-42.5 708-54.5 708-64.5 708-68.5 708-62.0 708-102 Distance between centers 1.7" 43 mm 2.2" 55 mm 2.6" 65 mm 2.7" 69 mm 2.45" 62 mm 2.45" 102 mm Hole diameter 3/8" 10 mm 3/8" 10 mm 3/8" 10 mm 3/8" 10 mm 1/2" 12 mm 1/2" 12 mm
702
702-2S
704-4S
Stud Size 10 mm, 3/8" 1 x (8 mm, 5/16") 2 x (10 mm, 3/8") 1 x (8 mm, 5/16") 1 mm x (10 mm, 3/8") 4 x (10 mm, 3/8") 10 mm, 3/8"
The patented Contour Locking System is an innovative feature that allows for multiple battery management components to be connected to each other providing for a clean finished installation. These locking tabs can be found on battery switches, heavy-duty buss bars, fuse holders, distribution studs and breaker modules.
148
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
705
Rating (A) 1 x 50A, 2 x 25A 50 80 100 135 150 1 x 5A, 3 x 15A 2x10A
Stud Size 3/16" 5 mm 1/4" 6 mm 1/4" 6 mm 1/4" 6 mm 1/4" 6 mm 1/4" 6 mm 5/32" 4 mm 5/32" 4 mm
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
149
150
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
LED indications on Systemswitch Read out of the basic functions on the display, including indication of available power source, generator, shore power or inverter and load on inverter function.
Central energy management The MasterView Easy indicates AC current, amperage and frequency including the load on inverter mode. The 12/24V read out shows current, power (charge/discharge) and battery monitoring, and has a start/stop generator.
Suitable for MasterBus As the Mass Systemswitch is suitable for MasterBus, all the information can also be read out on, for instance, a MasterView display, including the status of the charge current and the inverter.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
151
Masterswitch 5 kW Item # Input Nominal input voltage Input voltage range Number of inputs Number of outputs Dimensions, hxwxd Weight Version With automatic circuit breakers Connection for remote control MasterBus compatible LED indication on cabinet Nominal input current generator Nominal input current shore Nominal input current inverter Earth leakage switch Generator input switch Time delay generator input Output Nominal current shortbreak output Nominal current power output Nominal current generator output Automatical circuit breakers Technical Specifications Power consumption (AC all inputs) Power consumption (only inverter power) Temperature range (specified) Temperature range (allowed) Temperature range (storage/non operating) Relative humidity Transfer time Frequency watch Mechanical Cable size Protection degree 0.5-10 mm2/AWG 20-7 IP55 7VA no load consumption -5C to 60C n.a. 20A n.a. no, system dependent no no no no 20A 20A n.a. n.a. no 0-10 sec (adjustable) 230V (50/60Hz) 200-250V AC 2 1 7.9"x4.3"x4.5" 200x110x115 mm 2.6 lbs / 1.2 kg 55006010
Masterswitch 10 kW 55006015 230V (50/60Hz) 200-250V AC 2 1 7.9"x4.3"x4.5" 200x110x115 mm 2.9 lbs / 1.3 kg no no no no 40A 40A n.a. n.a. no 0-10 sec (adjustable) n.a. 40A n.a. no, system dependent 7VA no load consumption -5C to 60C
Masterswitch 25 kW 55003500 230V (50/60Hz) 200-250V AC 2 1 11.5"x9.5"x6.6" 291x241x168 mm 8.4 lbs / 3.8 kg no no no no 125A 125A n.a. n.a. no 0-10 sec (adjustable) n.a. 125A n.a. no, system dependent 26VA no load consumption -5C to 60C
Masterswitch Fuses 5 kW 55006060 230V (50/60Hz) 200-250V AC 2 2 7.9"x10"x4.5" 200x255x115 mm 4.6 lbs / 2.1 kg no no no no 16A 16A 20A yes (1x) no 0-10 sec (adjustable) 6A + 6A + 6A 6A + 10A n.a. yes 7VA no load consumption -5C to 60C
-25C to 70C (may not meet the specified tolerancies) -60C to 80C -60C to 80C -60C to 80C -60C to 80C
maximum 95%, non condensing switch on 12-22 ms / switch off 4-19 ms no no 0.5-10 mm2/AWG 20-7 IP55
maximum 95%, non condensing switch on 12-22 ms / switch off 4-19 ms no 4-50 mm2/AWG 10-1/0 IP55 no 0.5-10 mm2/AWG 20-7 IP55
* Also available in 9 kW, Item # 55106200. Specifications identical to 7 kW, except current is 80A.
For detailed specifications, scale drawings, 3D files, certificates, manuals and 120V models see mastervolt.us/transfer-systems
152
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Mass Systemswitch 6 kW 55008005 230V (50/60Hz) 200-250V AC 3 3 13.4"x10.3"x5.7" 340x261x144 mm 9.7 lbs / 4.4 kg no yes yes
Mass Systemswitch 10 kW 55008105 230V (50/60Hz) 200-250V AC 3 4 13.4"x10.3"x5.7" 340x261x144 mm 10.8 lbs / 4.9 kg no yes yes
Mass Systemswitch 16 kW 55008205 230V (50/60Hz) 200-250V AC 3 4 13.4"x10.3"x5.7" 340x261x144 mm 11 lbs / 5 kg no yes yes
Masterswitch 3 kW 55106000 120V (50/60Hz) 100-125V AC 2 1 7.9"x4.3"x4.5" 200x110x115 mm 2.6 lbs / 1.2 kg no no no no 25A 25A n.a. n.a. no
Masterswitch 7 kW 55106100* 120V (50/60Hz) 100-125V AC 2 1 7.9"x6.1"x5.8" 200x154x148 mm 5.5 lbs / 2.5 kg no no no no 60A 60A n.a. n.a. no 0-10 sec (adjustable) n.a. n.a. 60A no, system dependent 7VA no load -5C to 60C
indication voltage sources present and load on inverter mode 25A 25A 25A no 40A 25A 25A no 63A 40A 25A no
continuous monitoring of voltage and frequency 0-10 sec (adjustable) 25A 25A n.a. no, system dependent 27VA <1VA -5C to 60C 0-10 sec (adjustable) 25A 25A 40A no, system dependent 33VA <1VA -5C to 60C 0-10 sec (adjustable) 25A 40A 63A no, system dependent 33VA <1VA -5C to 60C
0-10 sec (adjustable) n.a. n.a. 25A no, system dependent 7VA no load -5C to 60C
-25C to 70C (may not meet the specified tolerancies) -60C to 80C -60C to 80C -60C to 80C -60C to 80C -60C to 80C
maximum 95%, non condensing switch on 12-22 ms / switch off 4-19 ms yes yes yes
maximum 95%, non condensing switch on 12-22 ms / switch off 4-19 ms no 0.5-10 mm2/AWG 20-7 IP55 no 0.5-10 mm2/AWG 20-7 IP55
0.5-10 mm2/AWG 20-7, remote control: 0.14-2.5 mm2/AWG 26-13 IP23 IP23 IP23
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
153
TM
154
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage | MasterBus
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
155
MasterView System
This full color graphical display helps installers to configure the electrical onboard system, and is extremely easy to reproduce. Configuration, monitoring and operation becomes easier, cheaper, lighter, faster & good looking. The software makes complicated electrical systems understandable for ship owners. Electricity has become fun to operate! Item # Display Dimensions, hxw MasterBus connection Power Power consumption Protection degree Weight Languages 77010400 10.4" colour touch screen 8.7"x10.8" / 222x276 mm by means of System Panel Controller (delivered as standard) by means of System Panel Controller (delivered as standard) 28W IP65 (front) 3.1 lbs / 1.4 kg ENG, NL, DE, SP, IT, FRA, FIN, SWE, DEN, NOR
System overview This screen gives a dynamic graphical overview of your electric system, answering any questions you have in an instant. Incorrect line voltages are shown in red, inactive circuits in grey: It couldnt be easier.
Home screen The home screen provides a status overview of power sources like shore connections, inverters, generators and batteries. A basic form of control is possible, for example turning on and off your inverter.
Digital switching screen This screen shows the layout of your yacht, lights and selected pumps. You manage the loads by clicking the icons. The background image can be uploaded for full customisation. Alarm notifications are shown via eye-catching pop-ups.
Tank level screen Stop guessing and know immediately the contents of up to 20 tanks. You can also install your own warning signals for full or (nearly) empty tanks. All you need to do is connect the MasterBus Tanklevel Interface to the MasterBus system.
Favourites screen The favourites screen can be custom designed to meet your specific needs for information and control. Any information that is available on the MasterBus network can be shown in the most logical way. Multiple pages can display information, for example, one overview page, one or two breaker pages, an engine information page and a NMEA2000 information page.
156
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage | MasterBus
MasterView Easy
Control panel for all MasterBus products This touch screen panel offers excellent readability and easy operation. The grey button allows you to turn the display on and off or (un)lock the touch screen. Further operation is via the touch screen. The first (of three) operation level shows a quick system overview - the information you need on a day-to-day basis. Product overview & configuration offers more detailed information and the option to change settings. As the MasterBus plug & play connection offers both data and power, only one cable is needed to connect the panel. Benefits: Clearly lit display. Push button for on/off and blockade for unwanted operation. Touchscreen operation for all functions. White background lighting - red colour for alarm function or night lights. Buzzer and alarm function. Installation requires only one MasterBus cable for both data and power supply. Low power consumption. Easy to install, the panel can be flush and surface mounted. Item # Display Dimensions, hxw MasterBus connection Powered by Power consumption Protection degree Weight Languages 77010305 3.5" touch screen 4.3"x4.3" / 110x110 mm yes MasterBus 160 mW IP21 0.51 lbs / 230 gr ENG, NL, DE, SP, IT, FRA, FIN, SWE, DEN, NOR
MasterView Read-out
Remote panel for reading the charge status of your battery charger, including error notifications. Item # Display Dimensions, hxw MasterBus connection Powered by Power consumption Protection degree Weight 77010050 7 LEDs 2.4"x2"x6" / 60x65 mm yes MasterBus 144 mW IP21 0.15 lbs / 70 gr
The MasterView series will be expanded in the course of 2011. For more information, see mastervolt.com/masterview.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
157
MasterShunt
This ultra-modern battery monitor provides detailed information on the status of your batteries, including voltage, current, remaining time and used capacity in percentages so no more unpleasant surprises. With an intelligent connection system, the MasterShunt is easily connected to the DC Distribution. The integrated system clock combined with command-based events automates your system according to your needs. A good example of such system automation: The generator should start automatically when the batteries are almost depleted. The MasterShunt also has a built-in robust main fuse that can safely break short-circuit currents of 50,000 amps. MasterShunt 500 77020100 5.9"x5.9"x2.5" / 150x150x65 mm 2.2 lbs / 1 kg gel, AGM, wet, Lithium Ion, spiral 12, 24 or 48V DC 300A continuous / 500A for 5 minutes yes 500A T-fuse (300A continuous at 40 C) alarm, timers, auto start/stop for the generator warning low voltage, warning low state of charge, high voltage IP21 MasterShunt, temperature sensor, MasterBus Terminator, MasterBus cable, cable protections for DC connections
Item # Dimensions, hxwxd Weight Battery types Battery voltage Current MasterBus powering Main fuse System functionality Programmable alarms Protection degree Delivered with
Digital DC 10x10A
As the pinnacle of system intelligence, the Mastervolt Digital DC 10x10A has ten 10A outputs for all functions including lighting, pumps or electronics. It comes standard with intelligent alarm functions and luxury options include: Follow me home (light stays on for a specific time after you leave the vessel). (Delayed) dimming of lights (including ten built-in dimmers). Alarm signal for overload. Every output has a hardware and software fuse. Reset the fuses via the MasterBus network. Possibility of higher currents (up to 100A) with parallel switching of multiple outputs.
Item # Dimensions, hxwxd Weight Battery voltage Current MasterBus powering Standard fuses Spare fuse Alarm Protection degree Delivered with
DC Distribution 500 77020200 5.9"x7.9"x2.5" / 150x216x65 mm 2.6 lbs / 1.2 kg 12, 24 or 48V DC 300A continuous / 500A for 5 minutes yes 80, 80, 125, 160A - ANL type (deviating values can be ordered separately) 125A ANL type fuse monitoring IP21 5 fuses, hex tool, MasterBus Terminator, MasterBus cable, cable protections for DC connections
158
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage | MasterBus
DC Distribution 500
The DC Distribution 500 is the smallest distribution model available. It connects up to four DC devices to the DC groups, such as a battery charger, inverter, alternators and solar panels. With the included plug & play cable it can be easily connected to the MasterBus network. The MasterView panel gives all fuses logical names, for instance, referring to the connected equipment, to ensure you receive understandable error notifications (for example: battery charger fuse defect). Digital DC 10x10A 77020400 yes <2 mA at 12V / <2 mA at 24V (off board situation) IP21 1.7 lbs / 750 gr cable max. 4 mm 10A per channel 15A per channel max. 95 mm or directly connected to MasterShunt or DC Distribution 100A 8-30V DC
Item # MasterBus powering Power consumption Protection degree Weight DC Output Connection Maximum software fuse current Hardware fuse current DC Input Connections Maximum current Supply voltage
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
159
MasterBus Interfaces
The special MasterBus Interfaces increase the versatility of your MasterBus network. Connect multiple components to distribute information to your MasterBus products or connect products that require information from the MasterBus network, such as a NMEA2000 or Modbus network, and vice versa. All interfaces (and modules) can be installed in various ways, from DIN rails to surface mounting. Available in ten languages: English, Dutch, German, French, Spanish, Italian, Norwegian, Swedish, Finnish and Danish.
USB Interface
Allows you to read and configure your MasterBus system from your PC. Item # 77030100
Modbus Interface
The MasterBus Modbus Interface can provide all information from the closed MasterBus network for other monitoring and operating systems by means of the Modbus protocol. Item # 77030800
Inverter Interface
The MasterBus Inverter Interface integrates the Mastervolt Mass Sine inverter in a MasterBus network and allows it to be operated and monitored via MasterView or PC. Item # 77030700
Combi Interface
This interface integrates a Mastervolt Mass Combi in a MasterBus network and allows it to be operated or monitored via a MasterView panel or PC. Item # 77030475
Serial Interface
The MasterBus Serial Interface connects conventional Mastervolt products to the MasterBus. Data becomes permanently available to allow configuration, operation and monitoring via MasterView panels. Item # 77030450
NMEA2000 Interface
The MasterBus NMEA2000 Interface provides the MasterBus network with NMEA2000 information, and vice versa. Item # 77031800
160
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage | MasterBus
GPRS Module
The GPRS module communicates with your vessel via mobile phone, allowing you to monitor current information or operate the system by remote control via a text message or easy shortcuts. Alarm notifications per text message are optional. Item # 77031000
Digital Input
Connect up to four switches to the MasterBus network. Delivery includes cables from interface to switches. Item # 77030900
Digital AC 1x6A
The Digital AC 1x6A switches all AC loads up to 6A directly and higher loads via a relay, anywhere on board. Max. relay current is 6A (230V AC single pole). Item # 77031500
Repeater
Extends the maximum length of your MasterBus network. With integrated isolated power supply to power the MasterBus. Item # 77031100
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
161
AC power analyser
The AC power analyser is a multifunctional measuring device which can visualize the AC current and AC voltage, frequency, Cos Phi and the power of the system. On top of that it features the inverter control and a free programmable potential free contact. Item # 77031200
77031400
no
IP21
162
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage | MasterBus
MasterBus Terminator
The Terminators at both ends of the cable ensure interference-free operation, prevent reflection of data signals and ensure high communication speeds. Item # 77040000
DC Distribution Fuses
The DC Distribution standard comes with four ANL fuses: 80, 80, 125 and 160A, and a spare fuse of 125A. Replacement fuses and other amps: Amps 40 50 60 80 100 125 160 175 200 250 300 400 Item # 77049040 77049050 77049060 77049080 77049100 77049125 77049160 77049175 77049200 77049250 77049300 77049400
MasterShunt Fuse
The robust fuse (500A/160V DC, 50 kA short circuit current) is suitable for high short circuit currents from the batteries. Spare fuse available separately. Item # 77049000
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
163
TM
The CZone digital control & monitoring system is designed for manufacturers and installers of Marine, RV and Specialty Vehicles. It simplifies installation of electrical systems through the replacement of complicated, cumbersome wiring to switch and fuse panels, with state of the art, robust interfaces and light NMEA 2000 network cable. It also provides the end user a sophisticated solution through the automation of complicated control and monitoring issues associated with todays on board systems. Installation Builders recognize an immediate benefit with reductions in cable usage, harness weights and installation times. The CZone system also integrates many stand alone components into one intuitive system. Wiring is dramatically simplified, because the CZone system is designed to remove complex switching clusters and wiring runs. Integrated diagnostics ensures fault finding is simple. The CZone system is the digital networking system that is both cost-effective and scalable. Modules can easily be added into the system to best suit the OEM and end-users needs.
ZONE ONE
ZONE TWO
ZONE THREE
SWITCH CONTROL FOR LIGHT ONE DIMMER
ZONE FOUR
SWITCH CLUSTER
ZONE FIVE
LIGHT
LIGHT
TIMER
FAN
WATER PUMP
STEREO
BATTERY BANK
164
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Signal Interface
TM
Manage | CZone
NMEA 2000 Configuration Versatility & Security Network We provide the tools to help you determine the modules needed The CZone system, designed for 9-32V systems, features NMEA 2000 NMEA built-in timers, dimmers (including support for halogen lighting), based on your specific requirements. Then, simply program with Network T-Connector the CZone intuitive configuration tool. alarms, voltage reducers and load shedding. With safety in mind, the CZone system features a manual bypass. Our Integration No-Single-Failure-Point technology ensures a plug-n-play system The CZone system is NMEA 2000 compliant and uses the that is designed to handle mishaps. If a module is damaged, the standard Micro cables and connectors. Being NMEA 2000 system will automatically program the replacement module, compliant you can have trust in the network. This also allows a when it is plugged in. This means any module can be replaced single network backbone to be installed for multiple systems without using high tech service people. Our security features (CZone and other NMEA 2000 devices). Additionally, the allow custom configurations that can be locked. CZone system can share certain monitoring functions with other NMEA 2000 compliant screens.
TM
DC Wiring
The CZone system decentralizes the DC power distribution system, locates circuit control and protection modules closer to loads to shorten cable runs and reduce the size of conductors, significantly decreasing the cost and weight of the electrical wiring harness. The system replaces complex wiring with a single data wire. Complex switch panel wiring removed, replaced with single data cable connection The grouping of multiple loads into common areas (Zones) with Output Interfaces is the key to the system Heavy-duty battery mains cable, replaced by multiple smaller conductors
ZONE ONE
ZONE TWO
ZONE THREE
SWITCH CONTROL FOR LIGHT ONE
ZONE FOUR
SWITCH CLUSTER
ZONE FIVE
LIGHT
LIGHT
SIGNAL INTERFACE
WATER PUMP
STEREO
BATTERY BANK
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
165
TM
3.5" Display Interface 3.5" Transflective QVGA LCD IpX7 water ingress Protection Rotary Knob for easy menu navigation Simple User Interface Power consumption @12V: 180mA (standby 130mA) Dimensions (WxHxD): 4-3/32"x6-7/16"x2-13/32" 105x165x62 mm
3.5" Display
8" Touch Screen Screen size 8.4" (SVGA) IP Level IP64 Touch screen operation Dimensions (WxHxD): 9.212"x7.244"x1.65" 234x184x42 mm Brightness (cd/m2) 450 Input voltage 12V DC Power Consumption 20W 8" Touch Screen
10" Touch Screen Screen size 10.4" (SVGA) IP Level IP64 Dimensions (WxHxD): 10.866"x8.93"x1.99" 276x227x50.7 mm Brightness (cd/m2) 400 Input voltage 12V DC Power Consumption 25W
Description Display Interface, w/power cable, black bezel Display Interface, w/power cable, grey bezel Display Interface only, black Display Interface only, grey CZone 8" Touch Screen CZone 10" Touch Screen
166
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
TM
Manage | CZone
Power Control: Turn circuits on and off including timer and light dimming control Set modes of operation Monitoring: DC Power Meter: Displays voltages of multiple battery banks, includes low and high voltage alarms Displays charge and discharge (amps) of multiple battery banks Displays battery capacity in ampere hours and % charge/discharge, includes low ampere hour alarm Logging of battery minimum and maximum voltage levels Logging of minimum battery capacity level AC Power Meter: Displays multiple line voltages (230 and 110V), includes high and low voltage alarm Displays AC line frequencies, includes high and low frequency alarm and AC power consumption in kW Logging of minimum and maximum voltage and frequency levels Logging of maximum AC Current Tank Levels: View tank level information for multiple tanks and fluid types Data: Displays standard NMEA 2000 information Displays temperature and pressure values Alarms/diagnostics: Logging of circuit run time and on cycles CZone network status reporting Presents alarms for on board faults in audible and visual form (bilge pump running, smoke alarm)
Control: Breaks down the circuits into easy to identify groups for quick control, ie. to turn on fresh water pump open pumps group. User can open pumps group and select fresh water pump. This screen also allows the user to monitor the status of the circuit i.e. on, off, fault and current draw.
Monitoring: Allows user to easily monitor AC and DC power, tanks, data, alarms, and circuit status. Presents data in analog and digital form.
Modes: Key to the ease of operation. With one key press the user can turn on a group of circuits, without having to scroll, search for, and turn on the individual circuits that they need for operation of their vessel/vehicle. When leaving vessel or vehicle, simply press systems off to turn off all nonessential circuits. Entertainment mode allows preset activation of salon lights, music etc... All functions can be controlled remotely with The CZone system remote. Settings: Allows OEM or technician access to the configuration (via password) of a system. No need for computer to set or change configuration settings such as circuit labels, circuit breaker sizes, etc. (DI only)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
167
TM
80-911-0068-00
168
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
TM
Manage | CZone
80-911-0069-00
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
169
170
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
TM
Manage | CZone
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
171
TM
Signal Interface
The Signal Interface (SI) connects the CZone system to your external sensors, alarms and switching devices. The SI allows intelligent, automated operation of circuits depending on the state of the input. For example, the SI can be easily programmed to allow a fluid transfer pump and an alarm to turn on simultaneously when the SI detects that a low tank level has been reached. Connect standard switches to the SI to allow control of the CZone system outputs. The module provides LED status indications for each input. This allows fast diagnostics while providing information back to the CZones Display Interface. Accepts inputs from traditional switch types being used to control outputs Accepts inputs from switches to trigger alarm i.e. high water float switch Accepts inputs from industry standard tank senders (0-5V, 10-180Ohm, 240-33Ohm) Accepts inputs from general voltaic or resistive signals can be used for controlling outputs or to display a physical position i.e. show a hatch is partially open LED status indicators for each input Dimensions (WxHxD): 6-3/32"x3-29/32"x1-5/8" 156x100x42 mm IPX5 water ingress protection Outputs standard NMEA 2000 sentences Resistive input range 01000 Ohms Voltage sensing input range 034VDC
Signal Status Indicator
Terminal Block
172
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
TM
Manage | CZone
Meter Interface
The Meter Interface (MI) accepts inputs from external AC and DC power metering sensors. It then processes and converts the analog signals into digital strings that can then be presented, by the display, to the user, as one of several, easy-to-understand formats such as: AC and DC voltage and amps AC Kilowatts DC battery capacity in amp hours and % remaining All with user definable high and low alarms Intelligence is built into the CZone system. The MI can calculate the battery capacity as ampere hours and/or percentage of charge remaining. Since the CZone system provides both monitoring and control for DC systems, it can be configured to turn off non-essential circuits in the event that the battery is discharged to a low level. This helps to ensure that there is enough charge left in the battery to power safety critical circuits. AC 3 x AC voltage inputs (multi voltage) 2 x AC current inputs Calculates true RMS power DC 3 x DC voltage inputs (multi voltage) 2 x DC current inputs AC Voltage Indicator Calculates battery capacity as ampere hours and percentage charge remaining Resolution for current metering down to 0.1A DC Voltage Indicator General Dimensions (WxHxD): 6-3/32"x3-29/32"x1-5/8" 156x100x42 mm Network IPX5 water ingress protection Status Indicator Outputs standard NMEA 2000 power monitoring sentences Note: High and low alarm levels can be set for all inputs
Terminal Block
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
173
TM
Output Interface
The Output Interface (OI) provides an intelligent replacement for traditional circuit breaker and fuse panels. It has 6x high power, robust output channels which provide the power supply, control and fusing for a circuit as well as integrating many other built in features such as timers and dimmers. The OI is behind the CZone system concept of decentralizing the power distribution, compared to traditional electrical layouts which are typically based around a large, centralised circuit breaker or fuse panel. The OIs allow the installer to move the circuit control and protection closer to the loads which significantly shortens cable runs and reduces the size of the conductors. This equates to a reduction in the cost and weight of the electrical wiring harness, ie. less copper. Connection to the unit is simple: a large 6 way plug allows connections to cables of up to 16mm2 (6AWG) in size, or multiple smaller conductors. No need for specialized crimp terminals and expensive crimp tools to be carried for terminations to CZone, just a blade screwdriver. A protective flexible boot offers protection to the connections from harsh environment conditions. 4 levels of backup fusing including manual override (as required by ABYC) 6 x 20 amp circuits Programmable software fuse sizes Multiple channels can be bridged together to offer higher current switching Small, non metallic, easy to install case IPX5 water ingress protection Dimensions (WxHxD): 7-29/32"x5"x1-3/4" 200x128x45 mm Power consumption @12V: 85mA (standby 60mA)
DC Positive Feed
174
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
TM
Manage | CZone
Description Motor Output Interface w/ connector, boot Motor Output Interface only
Network Status indicator
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
175
TM
176
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
TM
Manage | CZone
Ext. Cable
NMEA 2000 Network Item # Item # Item # Item # 80-911-0024-00 80-911-0025-00 80-911-0026-00 80-911-0027-00 16 ft 32 ft 1.6 ft 6.5 ft 5m 10 m .5 m 2m
Power Cable
NMEA 2000 Network 3.2 ft, 1 meters Item # 80-911-0028-00
90 Elbow Connector
NMEA 2000 Network Item # 80-911-0046-00
Terminating Resistors
NMEA 2000 Network Item # 80-911-0030-00 Female Item # 80-911-0031-00 Male
Banking Caps
NMEA 2000 Network
Male Cap
Item # 80-911-0050-00
Female Cap
Item # 80-911-0051-00
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
177
TM
Item # 80-911-0052-00
178
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
TM
Manage | CZone
80-911-0062-00
80-911-0061-00
Push Buttons
Momentary and latched actuation options available Blue and red circuit status indication LED options 19mm mounting hole IP 67 environmental protection Stainless Steel components For use with CZone systems only Item # Item # Item # Item # 80-911-0060-00 80-911-0063-00 80-911-0062-00 80-911-0061-00 Momentary (ON)OFF Momentary ON/OFF Momentary (ON)OFF Momentary ON/OFF red LED red LED blue LED blue LED
Custom Switches
Item # Item # Item # Item # Item # Item # Red or blue systems in operation and backlighting LEDs red LED 80-911-0037-00 ON/OFF red LED 80-911-0038-00 mom ON/OFF red LED 80-911-0039-00 ON/OFF/ON red LED 80-911-0040-00 mom ON/OFF/mom ON blue LED 80-911-0066-00 mom ON/OFF blue LED 80-911-0071-00 mom ON/OFF/mom ON
DC Current Shunt
450A / 50 mV shunt supplied with 80-600-0021-00 3.25"Lx2.8"Wx2.75"H (83Lx45Wx44H mm) Item # LB-450-50
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
179
TM
AC Transducer
The AC-VSEN-4 includes 3 voltage transformers for up to 3 voltage inputs. Dimensions: 2.75"x5.5"x2" (69x140x50 mm) Item # AC-VSEN-4
Current Transformer
Maximum current 150A AC One CT-10-3 current transformer is supplied with ACSM. If a twin line system is in use, a second CT must be ordered. Dimensions: 1.5"x1.55"x.55" (37.5x39.2x13.7 mm) Hole size: 0.5" (12 mm) Supplied with 80-600-0023-00 Item # CT-10-3
180
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage: MonitoringDC
Manage | Monitoring
80-600-0021-00 (DCSM including 1x shunt and cable) 80-600-0022-00 (DCSM excluding shunt)
DC Power Meter Display Type Displays voltages of multiple Configure the DCSM to show battery banks (0-32V DC) the data in analog, digital and graphic form Displays charge and discharge (amps) of 2 battery banks Displays battery capacity in amp hours High/Low level alarms
Circuit Status View the status of important circuits (on/off) In graphic and numeric form
Tank Level View tank level information for multiple tanks in numeric and graphic forms. Resetable when leaving boat
DC Current Shunt
450A / 50 mV shunt supplied with 80-600-0021-00 3.25"Lx2.8"Wx2.75"H (83Lx45Wx44H mm) Item # LB-450-50
Sprayproof Gasket
When fitted the gasket provides a water ingress protection level of IPX5 (Protection against low pressure jets of water) for the AC and DC systems monitors Item # GAS-SM
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
181
Manage: MonitoringAC
AC Power Meter Displays AC volts, amps frequency and power for two supplies with a third position for monitoring AC volts and frequency of a third supply Displays AC power in kW (true RMS)
Alarms High and low alarms for each input User selectable alarm levels Mutable
AC Transducer
The AC-VSEN-4 includes 3 voltage transformers for up to 3 voltage inputs. Dimensions: 2.75"x5.5"x2" (69x140x50 mm) Item # AC-VSEN-4
Current Transformer
Maximum current 150A AC One CT-10-3 current transformer is supplied with ACSM. If a twin line system is in use, a second CT must be ordered. Dimensions: 1.5"x1.55"x.55" (37.5x39.2x13.7 mm) Hole size: 0.5" (12 mm) Supplied with 80-600-0023-00 Item # CT-10-3
182
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Item # Number of battery sets Max. amp-hour capacity Voltage read-out Current read-out Amp-hours read-out Time remaining indication Battery capacity in % Current consumption (backlight off) Current consumption (backlight on) Supply voltage Voltage range measurement Voltage resolution Voltage deviation Amps measurement range Shunt specification Dimensions instrument, wxh Built-in depth incl./excl. cover box Weight instrument incl. shunt Dimensions shunt, hxwxd
70403163 service (fully), starter & bowthruster 9999Ah yes yes yes yes yes 14 mA/12V - 11 mA/24V 100 mA/12V - 50 mA/24V 9-35V DC 7-35V DC 0.01V 0.6% 1 figure 0-500A (optional 1000A/50mV) 500A / 50mV (included) 4.7"x2.6" / 120x65 mm 2.2"/1.6" / 55/40 mm 2 lbs / 0.9 kg 3.3"x1.7"x1.7" / 84x44x44 mm - M8
Manage | Monitoring
Tank Sender
Suits tanks with maximum depth of 280 mm and a maximum wall thickness of 10 mm, and a maximum hole size of 22 mm. Comes with 5 m cable. Item # RV-TS-5M
Tank Sender
Well nut hole size 3/8" (9 mm). Cable length 5 m. One kit supplied with 600-TG. Item # 600-TGSK
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
183
Manage: MonitoringTank
TS1
the most unique and sophisticated system of any tank monitor tested the ultrasonic technology is extremely accurate. Practical Sailor Magazine, July 2009
95.27 [3 3/4"]
0.5M
BEPs proprietary Windows based software application allows for TS1 senders to be programmed specific to tank shape, size and fluid type via a computers USB port. Programming is a simple process and can be carried out by downloading free software from bepmarine.com and purchasing a programming kit TS1-PK. Once programmed, the specific tank parameters are stored in the non-volatile memory of the TS1. Find more detailed information at bepmarine.com
84.88 [3 5/16"]
184
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Gas Detectors
The BEP Detectors use microprocessor control to ensure correct sensor sensitivity. The Detectors have the capability to control two sensors which detect both LPG and Petrol, with visual and audible alarms. Dual sensors for LPG and Petrol Self-testing Visual and audible alarms; provision Provision of bilge blower for external alarm 2.4"x3.5"x0.7" Automatic shut-off solenoid control (67x88x17 mm) with pulse and hold circuit for low power draw (600-GDL only) 600-GD, 600-GDL, & FD-2 Specifications Voltage (V DC) Current (mA) Alarm Sensitivity Current@Out (mA) Solenoid (mA) 1032 350 max. 20% lower explosive limit 800 max. 700 pulse, 250 hold
Manage | Monitoring
600-GD 600-GD will detect LPG, Petrol and CNG fumes. Supplied with one sensor, with an option for a second sensor, Item # BL-SL-L output for remote alarm and blower unit. 600-GD can be used on 12 or 24V systems.
600-GDL Same features as the 600-GD, with the ability to switch a valve on. It contains a unique Pulse & Hold circuit within the detector. This allows the valve to be pulled in at 12V and then once energized it will step down to hold the valve in place. This reduces power consumption and heat while the gas is turned on.
BL-SL-L One Sensor lead supplied (5 m) with GD & GDL. Second Sensor lead ordered separately
600-LPG 600-LPG is a stand alone gas shut-off system with no gas detection ability. For 12V systems order VR2.2 separately. For 24V systems order VR2.2-24V.
600-GDRV 600-GDRV has the sensor mounted in the front facia creating a stand alone unit. The unit is designed to be surface mounted at the vessels lowest point.
FD-2 FD-2 is designed for an economic in-dash installation. Supplied with sensor (5 m cable) which is capable of detecting combustible gases.
Solenoid Valve
The SA296COMP-12V is suitable for countries where VR2.2 is not approved. The CE approved SA296COMP-12V can be installed by an approved gas installer using approved components from within specific markets. 12V or 24V options available. Uses 1/4" BSP thread. Note: A separate regulator will need to be installed with the SA296 valves. Item # SA296COMP-12 12V Item # SA296COMP-12 24V
MARINCO | marinco.com
MASTERVOLT | mastervolt.us
185
Manage: MonitoringAnalog
Analog
Analog meters as used in BEP Contour circuit breaker panels. All analog meters accurate to within 2.5%
N816DCV
NO300ACV
NO100A
NO60ACT
Label Sheet 1 1 12 12
SOP1
SOP2
186
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
48.30mm (1 7/8)
Division Item # Range Marks 8-16V DC 0.2V N816DCV 0.4V N1632DCV 16-32V DC Volt 10V N0150ACV 0-150V AC (AC) 20V N0300ACV 0-300V AC Amp 0-60A AC 5A N060ACT (AC) 5A N0100ACT 0-100A AC CT-10-AN must be ordered when using N060ACT or N0100ACT. Meters Volt (DC)
48.30mm (1 7/8)
32.20mm (1 1/4)
59.71mm (2 3/8)
Division Item # Range Marks Shunt Type 0-10A DC 0.5A Internal N010A 29.10mm (1 1/8) 0-20A DC 1A Internal N020A 0-50A DC 2A 50A-50mV N050A 0-100A DC 5A 100A-50mV N0100A 0-150A 1A 150A-50mV N0150A When ordering optional external shunt ammeters, shunts must be ordered separately. Meters Amp (DC)
.0 3
1 5
m 0m
) 2 (
Manage | Monitoring
115.55mm (4 9/16)
87.16mm (3 7/16)
80-601-0020-00
80-601-0025-00
Cut-Out Dimensions
47.09mm (1 7/8)
Panel switchable for use on up to 3 different ammeter shunts Supplied with 1 shunt, meter scales available, 0-50A 0-100A 0-150A Item # 80-601-0024-00 80-601-0025-00 80-601-0026-00 Range 050A DC 0100A DC 0150A DC Inputs 3 3 3
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
187
95.00mm (3 3/4)
Can I use regular wire for my boat? The answer to this common question is a qualified yes, if the wire is SAE (Society of Automotive Engineering) J378, J1127 or J1128. These wires are designed for surface vehicles, not for the special requirements of the marine industry, but meet the minimum standards for boats in limited circumstances. Even if tinned copper, they should not be run in bilge spaces or other areas subject to moisture from spray or dripping. They should not be run in engines spaces, unless marked oil resistant and 75C. They should not be used in applications where subjected to vibration or frequent flexing and must never be used for 110 volt applications. For safety, use only wire which is marked with size and type. Most importantly, SAE wire is up to 12% smaller than AWG Boat Cable which means that, in many applications, larger
gauge wire must be used to stay within the voltage drop limits recommended by experts (see Tables C & D). The wire charts found in Chapmans Piloting and other publications are all for AWG wire like Ancor, not SAE type wire. Using the wrong type of wire can cost you more in the long run. Insist on Marine Grade Boat Cable by Ancor. It is UL approved for the corrosive marine environment and charter boat service. Marine Grade Boat Cable is specially designed to exceed all test standards for cold bend, moisture and oil resistance, heat shock and flammability. This ensures the safest, easiest to install, longest lasting and ultimately the least expensive electrical system you can buy. Only Ancor offers a complete line of Marine Grade Boat Cable for every need.
Grey Orange
Pink Purple
Common Feed Fuel Gauge Ignition Instrument Feed Bilge Blowers Starting Circuit Water Temperature Tilt Down and/or Trim In Tilt Up and/or Trim Out
Brown w/ Yellow Stripe Yellow w/ Red Stripe Tan Green/Stripe (G/x) (except G/Y) Blue/Stripe (Bl/x)
188
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
3% Voltage Drop at 12 Volts Length 10' 3 m 15' 5 m 20' 6 m 25' 8 m 30' 9 m 40' 12 m 50' 15 m 60' 18 m 70' 21 m 80' 24 m 90' 27 m 100' 30 m 110' 33 m 120' 36 m 130' 40 m 140' 43 m 150' 46 m 160' 49 m 170' 52 m Current (Amps) 5 10 15 18 14 12 16 12 10 14 10 10 12 10 8 12 10 8 10 8 6 10 6 6 10 6 6 8 6 4 8 6 4 8 4 2 6 4 2 6 4 2 6 4 2 6 2 2 6 2 2 6 2 1 6 2 1 6 2 1 Current (Amps) 5 10 15 18 18 16 18 16 14 18 14 12 16 12 12 16 12 10 14 10 10 12 10 8 12 10 8 12 8 6 10 8 6 10 8 6 10 6 6 10 6 6 10 6 4 8 6 4 8 6 4 8 6 4 8 6 4 8 6 2 Current (Amps) 5 10 15 18 18 16 18 16 14 18 16 12 18 14 12 16 14 10 16 12 10 14 12 8 14 10 8 12 10 6 12 10 6 12 8 6 12 8 6 10 8 6 10 8 6 10 8 6 10 6 6 10 6 6 10 6 4 8 6 4 20 10 10 8 6 6 6 4 4 2 2 2 2 2 1 1 1/0 1/0 1/0 2/0 25 10 8 6 4 6 4 4 2 2 2 1 1 1 1/0 1/0 2/0 2/0 2/0 3/0 30 8 8 6 4 6 4 2 2 1 1 1/0 1/0 1/0 2/0 2/0 3/0 3/0 3/0 3/0 40 6 6 6 4 4 2 2 1 1/0 1/0 2/0 2/0 2/0 3/0 3/0 4/0 4/0 4/0 4/0 50 6 6 4 2 4 2 1 1/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 60 6 4 4 2 2 1 1/0 2/0 3/0 3/0 4/0 4/0 4/0 70 6 4 2 2 2 1/0 2/0 3/0 3/0 4/0 4/0 80 6 4 2 2 2 1/0 3/0 3/0 4/0 4/0 90 4 2 2 1 1 2/0 4/0 4/0 4/0 100 4 2 2 1 1 2/0 4/0 4/0
3% Voltage Drop at 24 Volts Length 10' 3 m 15' 5 m 20' 6 m 25' 8 m 30' 9 m 40' 12 m 50' 15 m 60' 18 m 70' 21 m 80' 24 m 90' 27 m 100' 30 m 110' 33 m 120' 36 m 130' 40 m 140' 43 m 150' 46 m 160' 49 m 170' 52 m 20 14 12 10 10 10 8 6 6 6 6 4 4 4 4 2 2 2 2 2 25 12 12 10 10 8 6 6 6 4 4 4 4 2 2 2 2 2 2 1 30 12 10 10 8 8 6 6 4 4 4 2 2 2 2 2 1 1 1 1 40 10 10 8 6 6 6 4 4 2 2 2 2 1 1 1 1/0 1/0 1/0 2/0 50 10 8 6 6 6 4 4 2 2 2 1 1 1/0 1/0 1/0 2/0 2/0 2/0 3/0 60 10 8 6 6 4 4 2 2 1 1 1/0 1/0 1/0 2/0 2/0 3/0 3/0 3/0 3/0 70 8 6 6 4 4 2 2 1 1 1/0 1/0 2/0 2/0 3/0 3/0 3/0 3/0 4/0 4/0 80 8 6 6 4 4 2 2 1 1/0 1/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 4/0 4/0 90 8 6 4 4 2 2 1 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 4/0 4/0 4/0 100 6 6 4 4 2 2 1 1/0 2/0 2/0 3/0 3/0 4/0 4/0 4/0
3% Voltage Drop at 32 Volts Length 10' 3 m 15' 5 m 20' 6 m 25' 8 m 30' 9 m 40' 12 m 50' 15 m 60' 18 m 70' 21 m 80' 24 m 90' 27 m 100' 30 m 110' 33 m 120' 36 m 130' 40 m 140' 43 m 150' 46 m 160' 49 m 170' 52 m 20 16 14 12 12 10 10 8 8 6 6 6 6 6 4 4 4 4 4 2 25 14 12 12 10 10 8 8 6 6 6 6 4 4 4 4 2 2 2 2 30 14 12 10 10 8 8 6 6 6 4 4 4 4 2 2 2 1 1 1 40 12 10 10 8 8 6 6 4 4 4 2 2 2 2 2 1 1 1 1 50 12 10 8 8 6 6 4 4 2 2 2 2 2 1 1 1/0 1/0 1/0 1/0 60 10 8 8 6 6 4 4 2 2 2 2 1 1 1/0 1/0 1/0 2/0 2/0 2/0 70 10 8 6 6 6 4 2 2 2 1 1 1/0 1/0 1/0 2/0 2/0 2/0 3/0 3/0 80 10 8 6 6 4 4 2 2 1 1 1/0 1/0 1/0 2/0 2/0 3/0 3/0 3/0 3/0 90 8 6 6 6 4 2 2 2 1 0 1/0 2/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 100 8 6 6 4 4 2 2 1 0 0 2/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 4/0
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
189
10% Voltage Drop at 12 Volts Length 10' 3 m 15' 5 m 20' 6 m 25' 8 m 30' 9 m 40' 12 m 50' 15 m 60' 18 m 70' 21 m 80' 24 m 90' 27 m 100' 30 m 110' 33 m 120' 36 m 130' 40 m 140' 43 m 150' 46 m 160' 49 m 170' 52 m Current (Amps) 5 10 15 18 18 18 18 18 16 18 16 14 18 16 14 18 14 12 16 14 12 16 12 10 14 12 10 14 10 8 14 10 8 12 10 8 12 10 8 12 8 8 12 8 6 12 8 6 10 8 6 10 8 6 10 8 6 10 6 6 Current (Amps) 5 10 15 18 18 18 18 18 18 18 18 18 18 18 16 18 18 16 18 16 14 18 16 14 18 14 12 16 14 12 16 14 12 16 12 10 16 12 10 14 12 10 14 12 10 14 12 10 14 10 8 14 10 8 14 10 8 12 10 8 Current (Amps) 5 10 15 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 16 18 16 14 18 16 14 18 14 14 18 14 12 18 14 12 16 14 12 16 14 12 16 12 10 16 12 10 14 12 10 14 12 10 14 12 10 14 12 10 20 16 14 14 12 12 10 10 8 8 8 6 6 6 6 6 6 4 4 4 25 16 14 12 12 10 10 8 8 6 6 6 6 6 4 4 4 4 4 2 30 14 12 12 10 10 8 8 6 6 6 6 4 4 4 4 2 2 2 2 40 14 12 10 10 8 8 6 6 6 4 4 4 2 2 2 2 2 2 2 50 12 10 10 8 8 6 6 4 4 4 2 2 2 2 2 1 1 1 1 60 12 10 8 8 6 6 4 4 2 2 2 2 2 1 1 1 1/0 1/0 1/0 70 10 8 8 6 6 6 4 2 2 2 2 1 1 1 1/0 1/0 1/0 2/0 2/0 80 10 8 8 6 6 4 4 2 2 2 1 1 1/0 1/0 1/0 2/0 2/0 2/0 2/0 90 10 8 6 6 6 4 2 2 2 1 1 1/0 1/0 1/0 2/0 2/0 2/0 3/0 3/0 100 10 8 6 6 4 4 2 2 1 1 1/0 1/0 1/0 2/0 2/0 2/0 3/0 3/0 3/0
10% Voltage Drop at 24 Volts Length 10' 3 m 15' 5 m 20' 6 m 25' 8 m 30' 9 m 40' 12 m 50' 15 m 60' 18 m 70' 21 m 80' 24 m 90' 27 m 100' 30 m 110' 33 m 120' 36 m 130' 40 m 140' 43 m 150' 46 m 160' 49 m 170' 52 m 20 18 18 16 16 14 14 12 12 10 10 10 10 8 8 8 8 8 8 6 25 18 16 16 14 14 12 12 10 10 10 8 8 8 8 8 6 6 6 6 30 18 16 14 14 12 12 10 10 8 8 8 8 8 6 6 6 6 6 6 40 16 14 14 12 12 10 10 8 8 8 6 6 6 6 6 6 4 4 4 50 16 14 12 12 10 10 8 8 6 6 6 6 6 4 4 4 4 4 2 60 14 12 12 10 10 8 8 6 6 6 6 4 4 4 4 2 2 2 2 70 14 12 10 10 8 8 6 6 6 6 4 4 4 2 2 2 2 2 2 80 14 12 10 10 8 8 6 6 6 4 4 4 2 2 2 2 2 2 2 90 12 10 10 8 8 6 6 6 4 4 4 2 2 2 2 2 2 1 1 100 12 10 10 8 8 6 6 4 4 4 2 2 2 2 2 1 1 1 1
10% Voltage Drop at 32 Volts Length 10' 3 m 15' 5 m 20' 6 m 25' 8 m 30' 9 m 40' 12 m 50' 15 m 60' 18 m 70' 21 m 80' 24 m 90' 27 m 100' 30 m 110' 33 m 120' 36 m 130' 40 m 140' 43 m 150' 46 m 160' 49 m 170' 52 m 20 18 18 18 16 16 14 14 12 12 12 10 10 10 10 10 8 8 8 8 25 18 18 16 16 14 14 12 12 10 10 10 10 10 8 8 8 8 8 8 30 18 18 16 14 14 12 12 10 10 10 10 8 8 8 8 8 6 6 6 40 18 16 14 14 12 12 10 10 8 8 8 8 8 6 6 6 6 6 6 50 16 14 14 12 14 10 10 8 8 8 6 6 6 6 6 6 6 4 4 60 16 14 12 12 10 10 8 8 8 6 6 6 6 6 6 4 4 4 4 70 14 14 12 10 10 8 8 8 6 6 6 6 6 4 4 4 4 2 2 80 14 12 12 10 10 8 8 6 6 6 6 4 4 4 4 2 2 2 2 90 14 12 10 10 10 8 6 6 6 6 4 4 4 4 2 2 2 2 2 100 14 12 10 10 8 8 6 6 6 4 4 4 4 2 2 2 2 2 2
ABYC Recommends Conductors used for panelboard or switchboard main feeders, bilge blowers, electronic equipment, navigation lights, and other circuits where voltage drop must be kept to a minimum, shall be sized for a voltage drop not to exceed three percent. Conductors used for lighting, other than navigation lights, and other circuits where voltage drop is not critical, shall be sized for a voltage drop not to exceed 10 percent. 11.16.1.2.7.
190
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
AWG CM area 1,600 2,600 4,100 6,500 10,500 16,800 26,600 42,000 66,500 83,690 105,600 133,100 167,800 211,600
SAE CM area 1,537 2,336 3,702 5,833 9,343 14,810 24,538 37,360 62,450 77,790 98,980 125,100 158,600 205,500
Ampacity Engine Space Outside Inside 20 17 25 21 35 30 45 38 60 51 80 68 120 102 160 136 210 178 245 208 285 242 330 280 385 327 445 378
Ampacity Outside of Engine Space 20 25 35 45 60 80 120 160 180 210 245 285 330 385 445
Ampacity Inside of Engine Space (Note 1) 17 21 30 38 51 68 102 136 153 178 208 242 280 327 378
*De-rating for engine space is 0.85 for 221F (105C) rated wire.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
191
Table F is supplied to eliminate the need for calculating the corrections for multi-conductor cable bundles to Table E. The values are already corrected.
Note: These tables only apply for 221F (105C) wire and other premium wire and should not be used for lesser grades of wire and cable. Reprinted at the courtesy of the United States Coast Guard Electrical System Compliance Guideline. * There is NO LIMIT on conductors in a bundle under 50 volts.
192
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
193
UL 1426 Tinned Boat Cable Spool Color Length 4 AWG (21 mm2) Black 25' 50' 100' 250' 500' Red 25' 50' 100' 250' 500' Yellow 100' 500' 2 AWG (34 mm2) Black 25' 50' 100' 250' 400' Red 25' 50' 100' 250' 400' Yellow 50' 100' 400' 1 AWG (42 mm2) Black 25' 50' 100' 300' Red 25' 50' 100' 300' Item # 113002 113005 113010 113025 113050 113502 113505 113510 113525 113550 113910 113950 114002 114005 114010 114025 114040 114502 114505 114510 114525 114540 114905 114910 114940 115002 115005 115010 115030 115502 115505 115510 115530 Spool Length 25' 50' 100' 300' 1/0 AWG (53 mm2) Black 25' 50' 100' 250' Red 25' 50' 100' 250' Yellow 25' 50' 100' 250' 2/0 AWG (68 mm2) Black 25' 50' 100' 200' Red 25' 50' 100' 200' Yellow 25' 50' 100' 200' Color Yellow Item # 115902 115905 115910 115930 116002 116005 116010 116025 116502 116505 116510 116525 116902 116905 116910 116925 117002 117005 117010 117020 117502 117505 117510 117520 117902 117905 117910 117920 Spool Color Length 3/0 AWG (85 mm2) Black 25' 50' 100' 150' Red 25' 50' 100' 150' Yellow 50' 4/0 AWG (107 mm2) Black 25' 50' 100' Red 25' 50' 100' Yellow 25' 50' 100' Item # 118002 118005 118010 118015 118502 118505 118510 118515 118905 119002 119005 119010 119502 119505 119510 119902 119905 119910
194
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Marine Grade 18 4/0 AWG Wire and Cable Specifications Wire Size 18 AWG .08 mm2 16 AWG 1 mm2 14 AWG 2 mm2 12 AWG 3 mm2 10 AWG 5 mm2 8 AWG 8 mm2 6 AWG 13 mm2 4 AWG 21 mm2 2 AWG 34 mm2 1 AWG 42 mm2 1/0 AWG 53 mm2 2/0 AWG 68 mm2 3/0 AWG 85 mm2 4/0 AWG 107 mm2 Nominal O.D. 7/64" 3 mm 1/8" 3 mm 9/64" 4 mm 5/32" 4 mm 7/32" 6 mm 5/16" 8 mm 11/32" 9 mm 13/32" 10 mm 15/32" 12 mm 17/32" 14 mm 9/16" 14 mm 5/8" 16 mm 11/16" 18 mm 13/16" 21 mm Wt. per 1000' 12 lbs 5.4 kg 16 lbs 7.3 kg 23 lbs 10.4 kg 31 lbs 14 kg 44 lbs 20 kg 86 lbs 39 kg 118 lbs 53.5 kg 178 lbs 81 kg 277 lbs 126 kg 350 lbs 159 kg 437 lbs 198 kg 549 lbs 249 kg 675 lbs 306 kg 837 lbs 380 kg Stranding No. of 30 AWG 16 26 41 65 105 168 266 420 665 836 1064 1330 1665 2109 Cir. Mil Area 1600 2600 4100 6500 10,500 16,800 26,600 42,000 66,500 83,690 105,600 133,000 167,800 211,600 mm2 .0823 1.31 2.08 3.31 5.26 8.37 13.3 21.15 33.62 44.21 53.49 67.43 85.01 107.2 Ohms per 1000' 6.48 4 2.53 1.75 2.98 0.62 0.04 0.24 0.157 0.127 0.099 0.077 0.062 0.049
UL 1426 Tinned Boat Cable Features red and yellow Marine Grade primary conductors in a white common jacket. Spool Length Item # 18/2 AWG (2x0.8 mm2) 100' 124910 250' 124925 500' 124950 1000' 124999 16/2 AWG (2x1 mm2) 100' 124710 250' 124725 500' 124750 1000' 124799 14/2 AWG (2x2 mm2) 25' 124502 100' 124510 250' 124525 500' 124550 1000' 124599 Spool Length Item # 12/2 AWG (2x3 mm2) 100' 124310 250' 124325 500' 124350 10/2 AWG (2x5 mm2) 25' 124102 100' 124110 250' 124125 400' 124140 800' 124180 8/2 AWG (2x8 mm2) 50' 123905 100' 123910 6/2 AWG (2x13 mm2) 50' 123705 100' 123710 Flat Safety Cable Size (AWG) Nominal O.D. 18/2 3/16"x9/32" 5x7 mm 16/2 3/16"x5/16" 5x8 mm 14/2 7/32"x11/32" 6x9 mm 12/2 7/32"x3/8" 6x10 mm 10/2 1/4"x15/32" 6x12 mm 8/2 11/32"x5/8" 9x16 mm 6/2 13/32"x3/4" 10x19 mm
Wt. per 1000' 49 lbs 22.2 kg 51 lbs 23.1 kg 65 lbs 29.5 kg 82 lbs 37.3 kg 128 lbs 58.2 kg 230 lbs 104.5 kg 364 lbs 165.5 kg
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
195
Round Safety Cable Size (AWG) Nominal O.D. 16/2 5/16" 8 mm 14/2 11/32" 9 mm 12/2 13/32" 10 mm Wt. per 1000' 49 lbs 22.2 kg 63 lbs 28.6 kg 80 lbs 36.3 kg
Triplex Cable
Spool Length Item # 16/3 AWG (3x1 mm2) 100' 131710 250' 131725 500' 131750 1000' 131799 14/3 AWG (3x2 mm2) 100' 131510 250' 131525 500' 131550 900' 131590 12/3 AWG (3x3 mm2) 25' 131302 100' 131310 Spool Length Item # 16/3 AWG (3x1 mm2) 100' 133710 250' 133725 14/3 AWG (3x2 mm2) 100' 133510 250' 133525 900' 133590
Flat Cable Cable Size (AWG) Nominal O.D. 16/3 3/16"x15/32" 5x12 mm 14/3 7/32"x1/2" 6x13 mm 12/3 7/32"x17/32" 6x14 mm 10/3 1/4"x21/32" 6x17 mm 8/3 3/8"x1" 10x25 mm 6/3 7/16"x1-3/16" 11x30 mm Round Cable Cable Size (AWG) Nominal O.D. 16/3 11/32" 9 mm 14/3 13/32" 10 mm 12/3 7/16" 11 mm Wt. per 1000' 75 lbs 34 kg 96 lbs 43.6 kg 125 lbs 56.8 kg Wt. per 1000' 75 lbs 34 kg 96 lbs 43.6 kg 125 lbs 56.8 kg 186 lbs 84.5 kg 287 lbs 130.4 kg 470 lbs 213.6 kg
196
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Spool Length Item # 10/3 AWG (3x5 mm2) 500' 131151 Cable Size (AWG) Nominal O.D. Wt. per 1000' 10/3 1/4"x21/32" 186 lbs 6x17 mm 84.5 kg
Conductor Colors 16/4 AWG (3x3 mm2) Yellow, White, Green, Brown
Cable Size (AWG) Nominal O.D. Wt. per 1000' 16/4 3/16"x9/16" 105 lbs 4x14 mm 47.7 kg
Signal Cable
Tinned Boat Cable
Round Signal
100% Mylar Foil Shield and Drain Wire Tinned Boat Cable Conductor Spool Colors Length 20/8 AWG (8x0.5 mm2) Black, Red, Green, 100' Blue, Brown, 250' Orange, Purple, Yellow
Conductor Spool Colors Length 20/2 AWG (2x0.5 mm2) Black, Red 25' 100' 500'
Cable Size (AWG) Nominal O.D. Wt. per 1000' 20/2 5/32"x1/4" 18 lbs 4x6.4 mm 8.1 kg
Cable Size (AWG) Nominal O.D. Wt. per 1000' 20/8 5/16" 63 lbs 7.9 mm 28.6 kg
Spool Length Item # 14/2 AWG (2x2 mm2) 100' 141410 250' 141425 Cable Size (AWG) Nominal O.D. Wt. per 1000' 14/2 .330" 73.2 lbs 8.4 mm 33.3 kg
Conductor Spool Colors Length 20/3 AWG (3x0.5 mm2) Black, Red 100' 500'
Cable Size (AWG) Nominal O.D. Wt. per 1000' 20/3 7/32" 30 lbs 5.6 mm 13.6 kg
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
197
Conductor Spool Colors Length 16/2 AWG (3x3 mm2) Black, Red 100' 500'
Conductor Colors 16/4 AWG (4x1 mm2) Brown, Green, White, Yellow
Cable Size (AWG) Nominal O.D. Wt. per 1000' 16/2 1/8"x1/4" 32 lbs 3.2x6.4 mm 14.5 kg
Cable Size (AWG) Nominal O.D. Wt. per 1000' 16/4 1/8"x1/2" 62 lbs 3.2x12.7 mm 28 kg
Round Mast
UL 1426 Tinned Boat Cable
Conductor Colors 14/5 AWG (5x2 mm2) Black, Blue, Green, Brown, Red
Cable Size (AWG) Nominal O.D. Wt. per 1000' 14/5 1/2" 160 lbs 12.7 mm 79.5 kg
198
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Coaxial Cable
Premium Tinned Copper Features signal loss ratios of up to 50% less than other coaxial cables. Tinned copper center conductor as well as tinned copper outer braid for corrosion resistance and easy soldering. 96% braid for best signal strength and least interference with UV inhibited white jacket for longest life. Spool Length RG 58CU 100' 250' RG 59U 250' 500' Spool Length RG 213 100' 250' 500' RG 8X 100' 250' 500' 1000' Ancor Recommends RG 58CU for interconnecting electronic equipment. RG 59U for TVs and some SAT NAVs. RG 8X for VHF runs less than 50 feet.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
199
UL-1426 Tinned Boat Cable Ancor Marine Grade Standard Battery Cable Assemblies are manufactured with Ancors premium UL1426 tinned copper battery cable. The battery cable is fine stranded to produce maximum conductivity and flexibility. In addition, all Ancor battery cable is flame retarded, UV inhibited, rated to 600V and 105C. The lugs are tinned copper to avoid corrosion and last longer. Each end has a piece of Ancor's adhesive lined 3:1 heatshrink tubing placed over the electrical connection. The heatshrink tubing seals out moisture and other corrosive elements found in the marine environment, and provides strain relief to ensure a longer lasting battery connection. Color Length 4 AWG (21 mm2) Black 18" 45.7 cm 32" 81.2 cm 48" 121.9 cm Red 18" 45.7 cm 32" 81.2 cm 48" 121.9 cm 2 AWG (34 mm2) Black 18" 45.7 cm 32" 81.2 cm 48" 121.9 cm Red 18" 45.7 cm 32" 81.2 cm 48" 121.9 cm Stud Size 5/16" 5/16" 5/16" 3/8" 3/8" 3/8" 5/16" 5/16" 5/16" 3/8" 3/8" 3/8" 7.93 mm 7.93 mm 7.93 mm 9.5 mm 9.5 mm 9.5 mm 7.93 mm 7.93 mm 7.93 mm 9.5 mm 9.5 mm 9.5 mm Item # 189130 189134 189136 189131 189135 189137 189140 189144 189146 189141 189145 189147 For Continuous Current Draws up to: 136 amps 178 amps Use Battery Cable Assemblies 4 AWG 2 AWG
RG8X PVC 1/4" / 6.4 mm 16 19/29 96% 40 lbs / 18.1 kg 50 26.0 pF 2.5db 3.7db 13.5db 78%
RG8U PVC 13/32" / 10.3 mm 13 7/21 96% 110 lbs / 50 kg 52 29.5pF 1.3db 2.2db 8.9db 66%
200
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage: Terminals
Ring Terminals
Nylon Insulated with Insulation Grip Double Crimp, Funnel Entry UL 486C Screw Size Qty/Pkg 22-18 AWG 0.3-0.8 mm2 6" 3.6 mm 6 22 AWG 4 mm2 8" 4 mm 6 25 100 10" 4.8 mm 6 25 100 1/4" 6.4 mm 25 5/16" 7.9 mm 5 3/8" 9.5 mm 5 16-14 AWG 1-2 mm2 6" 3.6 mm 6 25 8" 4 mm 6 25 100 10" 4.8 mm 6 25 100 500 1/4" 6.4 mm 5 25 100 5/16" 7.9 mm 5 25 100 3/8" 9.5 mm 5 25 100 Item # 230201 230202 210202 220202 230203 210203 220203 210204 230205 230206 230211 210211 230212 210212 220212 230213 210213 220213 222213 230214 210214 220214 230215 210215 220215 230216 210216 220216 Screw Size Qty/Pkg Item # 12-10 AWG 3-5 mm2 6" 3.6 mm 5 230221 8" 4 mm 5 25 100 5 25 100 4 25 100 4 25 100 4 25 100 3 25 2 25 2 25 2 25 2 25 1 230222 210222 220222 230223 210223 220223 230224 210224 220224 230225 210225 220225 230226 210226 220226 230227 210227 230233 210233 230234 210234 230235 210235 230236 210236 230237 Screw Size 6 AWG 13 mm2 10" 4.8 mm 1/4" 6.4 mm 5/16" 7.9 mm 3/8" 9.5 mm 4 AWG 21 mm2 1/4" 6.4 mm 5/16" 7.9 mm 1/2" 12.7 mm Qty/Pkg Item # 1 1 1 1 1 1 1 230243 230244 230245 230246 230254 230255 230257
10"
4.8 mm
1/4"
6.4 mm
5/16"
7.9 mm
3/8"
9.5 mm
1/2"
12.7 mm
8 AWG 8 mm2 10" 4.8 mm 1/4" 5/16" 3/8" 1/2" 6.4 mm 7.9 mm 9.5 mm 12.7 mm
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
201
Manage: Terminals
Flanged Spades
Nylon Insulated with Insulation Grip Double Crimp, Funnel Entry UL 486A
Qty/ Screw Size Pkg Item # 2218 AWG 0.30.8 mm2 6" 3.6 mm 6 230301 8" 4 mm 6 230302 25 210302 10" 4.8 mm 6 230303 1614 AWG 12 mm2 6" 3.6 mm 6 230311 8" 4 mm 6 230312 25 210312 100 220312 10" 4.8 mm 6 230313 25 210313 100 220313 1210 AWG 35 mm2 8" 4 mm 5 230322 25 210322 100 220322 10" 4.8 mm 5 230323 25 210323 100 220323
Disconnects
.250 /6.4 mm Tab Size UL 310 Nylon Insulated with Insulation Grip Double Crimp, Funnel Entry
Qty/ Gender Pkg 1614 AWG 12 mm2 Female 5 25 100 Male 5 25 100 1210 AWG 12 mm2 Female 4 25 100 Male 4 25
Item # 230818 210818 220818 230819 210819 220819 230828 210828 220828 230829 210829
Qty/ Gender Pkg Item # 2218 AWG 0.30.8 mm2 Female 4 231408 25 211408 100 221408 Male 4 231409 25 211409 100 221409 1614 AWG 12 mm2 Female 4 231418 25 211418 100 221418 Male 4 231419 25 211419 100 221419 1210 AWG 35 mm2 Female 3 231428 25 211428 100 221428 Male 3 231429 25 211429 100 221429
Amps Volts Gang HxWxL 26 380 4 0.65"x0.83"x1.50" 16.5x21x38 mm 8 0.65"x0.83"x3.07" 16.5x21x78 mm 12 0.65"x0.83"x3.70" 16.5x21x94 mm
202
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage: Terminals
Qty/Pkg Item # 2218 AWG 0.30.8 mm2 7 230100 25 210100 100 220100 1614 AWG 12 mm2 7 230110 25 210110 100 220110 500 222110 1210 AWG 35 mm2 5 230120 25 210120 100 220120
Qty/Pkg Item # 2218 AWG 0.30.8 mm2 25 210161 100 220161 1614 AWG 12 mm2 25 210162 100 220162 500 222162 1210 AWG 35 mm2 25 210163 100 220163
Snap Plugs
Nylon Insulated with Insulation Grip UL 310 Double Crimp, Funnel Entry
Qty/ Gender Pkg Item # 2218 AWG 0.30.8 mm2 Male 4 230708 Female 4 230709 1614 AWG 12 mm2 Male 4 230718 25 210718 Female 4 230719 25 210719 100 220719
Specialty Connectors
3-Way Connector
Nylon Insulated with Insulation Grip Double Crimp, Funnel Entry UL 310
Multi-stack Connector
Nylon Insulated with Insulation Grip Double Crimp, Funnel Entry .250 tab 6.4 mm UL 310
Butt Connectors
Vinyl Insulated UL 486C
Splice Connectors
Qty/Pkg Item # 1614 to 2218 AWG 12 mm2 to 0.30.8 mm2 3 230164 25 210164 1210 to 1614 AWG 35 mm2 to 12 mm2 3 230165 25 210165
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
203
204
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Male
.250
6.4 mm
Pkg/Qty 10
Item # 300000
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
205
Manage: Terminals
DrySeal Connectors
Truly submersible, rated operable from -40F to 221F, under conditions of salt water spray and severe vibration. Sealing integrity is maintained even with exposure to gasoline, diesel fuel, anti-freeze, ozone and ultraviolet light to 3 feet. Seals intact under harsh conditions. Resistant to chemical exposure. One-piece, molded body. Conductor Qty/ Cable Size Description Colors Pkg Item # 14/2 2x2 mm2 Two Conductor Red, Yellow 1 249003
Installation Instructions for Twist-On Connectors To install Ancor twist-on connectors, strip the cable to expose 9/16" of the center conductor. Strip the outer jacket to expose 1/4" of the braid. Make sure that the braided shield does not touch the inner conductor. Insert the cable into the connector until the center conductor protrudes through the center of the connector. Twist the small knurled end while gently pushing the connector onto the cable until resistance is felt. Crimp or solder the center conductor. Cut off any excess. It is strongly recommended that a piece of Ancor 3/4" heat shrink be installed on all exterior UHF connectors to waterproof and relieve strain.
206
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage: Lugs
Heavy-duty Lugs
Ancor Marine Grade lugs are manufactured from heavy-duty annealed tinned copper, providing for maximum current flow. 100% tin plated copper resists corrosion from salt and moisture. Seamless barrel design allows for maximum strength when crimped. Closed end design seals out moisture so cables stay dry and corrosion free. 100% Tinned Copper UL 486A Screw Size 8 AWG 8 mm2 10" 4.8 mm Qty/Pkg Item # 2 25 100 2 25 100 2 25 100 2 25 100 2 10 2 25 2 25 2 25 100 2 25 100 1/1 252233 242233 244233 252234 242234 244234 252235 242235 244235 252236 242236 244236 252237 242237 252243 242243 252244 242244 252245 242245 244245 252246 242246 244246 252241 Screw Size 2 AWG 34 mm2 1/4" 6.4 mm 5/16" 7.9 mm Qty/Pkg Item # 2 25 2 25 100 2 25 100 2 1/1 252264 242264 252265 242265 244265 252266 242266 244266 252267 252261 Screw Size Qty/Pkg Item # 3/0 AWG 85 mm2 5/16" 7.9 mm 10 242715 3/8" 9.5 mm 2 252716 10 242716 1/2" 12.7 mm 2 252717 4/0 AWG 107 mm2 5/16" 7.9 mm 2 252725 10 242725 100 244725 3/8" 9.5 mm 2 252726 10 242726 100 244726 1/2" 12.7 mm 2 252727 10 242727
1/4"
6.4 mm
3/8"
9.5 mm
5/16"
7.9 mm
3/8"
9.5 mm
1/2"
12.7 mm
1/2" 12.7 mm 5/16" 7.9 & 9.5 & 3/8" mm 1 AWG 42 mm2 1/4" 6.4 mm 5/16" 7.9 mm 3/8" 9.5 mm
3/8"
9.5 mm
5/16" 7.9 & 9.5 & 3/8" mm 4 AWG 21 mm2 10" 4.8 mm 1/4" 6.4 mm
5/16"
7.9 mm
3/8"
9.5 mm
1/2"
12.7 mm
252253 242253 252254 242254 244254 252255 242255 244255 252256 242256 244256 252257 242257 252251
1/2" 12.7 mm 1/0 AWG 53 mm2 1/4" 6.4 mm 2 25 5/16" 7.9 mm 2 25 100 3/8" 9.5 mm 2 25 100 1/2" 12.7 mm 2 2/0 AWG 68 mm2 1/4" 6.4 mm 25 5/16" 7.9 mm 2 25 100 3/8" 9.5 mm 2 25 100 1/2" 12.7 mm 2 10
2 2 25 2 25 2
252274 252275 242275 252276 242276 252277 252284 242284 252285 242285 244285 252286 242286 244286 252287 242294 252295 242295 244295 252296 242296 244296 252297 242297
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
207
plus flat
68060300
68454002
red
min flat
68060400
68453014
black
double plus flat double min flat with bolt M10 plus with bolt M10 min with bolt M12 plus with bolt M12 min
Battery Clips
Color Red/Black Size 10A Qty/Pkg 1/1 Item # 260505
208
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Color Length 1/8" ALT Dia 3.2 mm Black 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm 48" 122 cm 3/16" ALT Dia 4.8 mm Black 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm 48" 122 cm 1/4" ALT Dia 6.4 mm Black 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm 48" 122 cm Clear 3" 7.6 cm Black/Red 3" 7.6 cm Red 48" 122 cm Yellow 48" 122 cm 3/8" ALT Dia 9.5 mm Black 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm 48" 122 cm Clear 3" 7.6 cm Blue 3" 7.6 cm 12" 30.5 cm Black/Red 3" 7.6 cm Red 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm 48" 122 cm 1/2" ALT Dia 12.7 mm Black 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm 48" 122 cm Red 3" 7.6 cm 12" 30.5 cm 48" 122 cm
Item # 301103 301106 301124 301148 302103 302106 302124 302148 303103 303106 303124 303148 303303 303602 303648 303948 304103 304106 304124 304148 304303 304403 304424 304602 304603 304606 304624 304648 305103 305106 305124 305148 305603 305624 305648
Color Length 3/4" ALT Dia 19 mm Black 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm 48" 122 cm Black/Red 3" 7.6 cm Red 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm 48" 122 cm Yellow 48" 122 cm 1" ALT Dia 25.4 mm Black 3" 7.6 cm 12" 30.5 cm 48" 122 cm 48" 122 cm Yellow 48" 122 cm Kits
Item # 306103 306106 306124 306148 306602 306603 306606 306624 306648 306948 307103 307124 307148 307648 307948
Qty/ Color Length Pkg 3/16"3/4" ALT Dia 4.819 mm Black 3" 7.6 cm 8 6" 15.2 cm 8 3/8" ALT Dia 9.5 mm Assorted 3" 30.5 cm 5 6" 122 cm 5 3/4" ALT Dia 19 mm Assorted 3" 7.6 cm 4 6" 4 12" 4
Adhesive Lined Tubing Specifications (3:1 ratio) Size 1/8" 3/16" 1/4" 3/8" 1/2" 3/4" 1" 3.2 mm 4.8 mm 6.4 mm 9.5 mm 12.7 mm 19 mm 25.4 mm Shrinks to 1/32" 0.8 mm 1/16" 1.6 mm 5/64" 2 mm 1/8" 3.2 mm 5/32" 4 mm 1/4" 6.4 mm 5/16" 7.9 mm Wire Range (AWG) <18 < 0.8 mm2 2012 0.5-3 mm2 1610 1-5 mm2 128 3-8 mm2 84 8-19 mm2 82/0 13-62 mm2 24/0 32-103 mm2
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
209
Black/Red Red
1"
Length 3" 7.6 cm 12" 30.5 cm 48" 122 cm 3" 7.6 cm 3" 7.6 cm 12" 30.5 cm 48" 122 cm 12" 30.5 cm 3" 7.6 cm 6" 15.2 cm 12" 30.5 cm
Item # 326103 326124 326148 326202 326603 326624 326648 327124 327202 327606 327624
Wire Range (AWG) 82/0 862 mm2 24/0 32103 mm2 4/0500 MCM 103253 mm2
210
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Cable Ties
Marinco offers a wide variety of materials, styles, and sizing options. A patented, DoubleLock design offers increased tensile strength that is 33% stronger than the industry standard cable tie. With a unique design and high-quality construction, Marinco cable ties provide a great solution for bundling wire, cable, hoses, cords and countless other applications.
TM
33%
ST
GRIP
RONGER
Item # 199200 199201 199202 199203 199246 199247 199248 199249 199204 199205 199206 199207 199254 199208 199209 199210 199211 199212 199213 199214 199215 199256
ST
GRIP
RONGER
no no no no yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes
yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes
Bundle Dia Max 13/16" 13/16" 13/16" 13/16" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 2" 2" 2" 2" 2" 3" 3" 3" 3" 4" 4" 4" 4" 4"
Tensile Strength 18 lbs 18 lbs 18 lbs 18 lbs 45 lbs 45 lbs 45 lbs 45 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs 75 lbs
33%
Item # 199259 199260 199216 199217 199218 199219 199220 199221 199222 199223
ST
GRIP
RONGER
yes yes no no no no no no no no
yes yes yes yes yes yes yes yes yes yes
Bundle Dia Max 4" 4" 4-9/10" 4-9/10" 7" 7" 10-3/10" 10-3/10" 14-3/10" 14-3/10"
Tensile Strength 120 lbs 120 lbs 175 lbs 175 lbs 175 lbs 175 lbs 175 lbs 175 lbs 175 lbs 175 lbs
33%
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
211
ST
GRIP
RONGER
no no no no
33%
Item # 199244 199245 199250 199251 199252 199253 199226 199227 199228 199229 199230 199257 199258
ST
GRIP
RONGER
no no no no no no no no no no no no no
yes yes yes yes yes yes yes yes yes yes yes yes yes
Bundle Dia Max 3/4" 3/4" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 2" 2" 2" 2" 4" 4" 4"
Tensile Strength 18 lbs 18 lbs 30 lbs 30 lbs 30 lbs 30 lbs 50 lbs 50 lbs 50 lbs 50 lbs 50 lbs 50 lbs 50 lbs
33%
ST
GRIP
RONGER
no no no no
yes yes no no
33%
ST
GRIP
RONGER
33%
212
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Mounting Bases
Nominal Diameter 3/16" 5 mm 1/4" 6 mm 5/16" 8 mm 3/8" 10 mm 7/16" 11 mm 1/2" 13 mm 9/16" 14 mm 5/8" 16 mm 3/4" 19 mm
Qty/ Pkg 10 10 10 10 10 10 10 10 10
Item # 403182 403252 403312 403372 403432 403502 403562 403622 403752
Nominal Diameter 7/8" 22 mm 1" 25 mm 1-1/4" 32 mm 1-1/2" 38 mm 1-3/4" 44 mm 2" 51 mm 2-1/2" 64 mm 3" 76 mm
Qty/ Pkg 10 10 10 10 10 10 10 10
Kit Description 1/8"1/2" (312 mm) Natural Nominal Diameter Thickness 3/16" 5 mm 0.04 1/4" 6 mm 0.04 5/16" 8 mm 0.04 3/8" 10 mm 0.04 7/16" 11 mm 0.06 1/2" 13 mm 0.06 5/8" 16 mm 0.06 3/4" 19 mm 0.06 1" 25 mm 0.06 1-1/4" 32 mm 0.06 1-1/2" 38 mm 0.06 1-3/4" 44 mm 0.06 2" 51 mm 0.06 2-1/2" 64 mm 0.06 3" 76 mm 0.06 #8 = 0.167 / #10 = 0.203 Qty/ Pkg 54 Item # 400000 Size #8 #8 #8 #8 #10 #10 #10 #10 #10 #10 #10 #10 #10 #10 #10
5/16" 3/8"
7 mm 9 mm
UV Black Natural UV Black Natural UV Black Natural Natural UV Black Natural UV Black Natural UV Black Natural UV Black Natural Natural
11 mm 12 mm 15 mm 19 mm 25 mm
1-1/4" 32 mm 1-1/2" 38 mm
Screw Width 3/8" 10 mm 3/8" 10 mm 3/8" 10 mm 3/8" 10 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm 1/2" 13 mm
4 mm 4 mm 4 mm 4 mm 5 mm 5 mm 5 mm 5 mm 5 mm 5 mm 5 mm 5 mm 5 mm 5 mm 5 mm
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
213
Cable Wraptor
Simple Design. Endless Solutions. T handle feature allows for easy carrying ropes, cordsets and extension cords. Large hang hole is perfect to store and hang. Stainless steel hinge and spring to prevent rusting. Large teeth design for secure locking system. Easy release trigger. Cable tie looping hole for permanent attachment. Spring-loaded hinge helps close tail.
HOLDS UP TO
HOLDS UP TO
150 lbs
100 lbs
HOLDS UP TO HOLDS UP TO
50 lbs
4"
2"
Medium
25 lbs
3"
Large X-Large
1"
Small
Description Register Pack Cable Wraptor Small Cable Wraptor Medium Cable Wraptor Large Cable Wraptor X-Large 2 Pack Carded Cable Wraptor 2 Medium Cable Wraptor 2 Large Cable Wraptor 1 Medium/1 Large
Qty/ Pkg Item # 50 25 25 20 2 2 2 CW-T1RR50 CW-T2RR25 CW-T3RR25 CW-T4RR20 CW-T2R2 CW-T3R2 CW-T2T3R2
Description Displays Cable Wraptor Desktop Display, Small Cable Wraptor Desktop Display, Medium Cable Wraptor Desktop Display, Large Cable Wraptor Gravity Feed, Medium Cable Wraptor Gravity Feed, Large Cable Wraptor Gravity Feed, X-Large Cable Wraptor Stackout Display, 100 M / 150 L / 40 XL
Qty/ Pkg Item # 50 25 25 75 50 40 290 CW-T1M50 CW-T2M25 CW-T3M25 CW-T2M75 CW-T3M50 CW-T4M20 CW-290
Wire Seals
Made of Nylon 6/6 flame resistant, self extinguishing Buna-N form seal. All seals exceed NEMA 4 x or 6 specs Overlapping clamping spines allow for superior pull-out protection and resistance Strain relief fittings are resistant to salt water, acids, alkalis, alcohol, oils and are non-corrosive for use in the marine environment. Good underwater to 300 feet /91.4 m (150 PSIG) provided there is a liquid tight seal between body and housing. Provide low cost cable entries into panels and junction boxes. UL 94 v-0 Thread Size 3/8" NPT 1/2" NPT 1/2" NPT 3/4" NPT 1" NPT Clearance Hole .68" .83" .83" 1.05" 1.35" Body Length .87" 1.06" 1.10" 1.22" 1.53" Thread Length .59" .51" .51" .51" .75" Qty/ Pkg 1 1 1 1 1
Description Round Cable Round Cable Round or Flat Cable Round Cable Round Cable
For Use with 1810 AWG 201 AWG 41, 14/210/2, 16/312/3 AWG 13/0 AWG 4/0 AWG
Cable Range .08".24" 26 mm .00"-.47" 012 mm .24"-.55" 614 mm .51"-.71" .71"-.98" 1318 mm 1825 mm
214
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
ABYC Recommends: Conductors that may be exposed to physical damage shall be protected by selfdraining; loom, conduit, tape, raceways, or other equivalent protection. 11.16.4.1.8. When AC and DC conductors are run together, the AC conductors shall be sheathed, bundled, or otherwise kept separate from the DC conductors. 11.16.4.1.5. Loom used to cover conductors shall be self-extinguishing. The base product (or resin) shall be classified as V-2 or better, in accordance with UL 94, Tests For Flammability Of Plastic Materials. 11.16.4.1.9. Spiral Wrap Specifications Nominal Diameter 1/4" 6 mm 3/8" 10 mm 1/2" 13 mm 3/4" 19 mm 1" 25 mm Bundle Range Min. Max. 0.188 2.0 4.8 mm 5 cm 0.313 3.0 8 mm 7.6 cm 0.375 4.0 10 mm 10.2 cm 0.750 5.0 19 mm 12.7 cm 1.000 7.0 25 mm 17.8 cm
Grommets
Provide instant abrasion resistance to wires passing through panel holes. Flexible black vinyl makes installation simple. Inside Hole Size Diameter Panel Width 3/8" 10 mm 1/4" 6 mm 3/32" 2 mm 1/2" 13 mm 3/8" 10 mm 1/16" 2 mm 1/43/4" Assortment Combo Pack Qty/ Pkg 5 5 45 Item # 760375 760500 750000
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
215
257 Piece Heat Shrink Connector Kit w/ Crimper & Mini Torch
110 pcs assorted 22-10 heat shrink butt connectors 145 pcs assorted 16-10 ring terminals 1 single crimp ratchet tool 1 mini butane pocket torch Item # 320001
Item # 255001
216
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage: Kits
Item # 220007
225 Piece Twin Kit Electrical Repair Kit with Strip/Crimp Tool
55 pcs assorted butt connectors 95 pcs assorted ring terminals 35 pcs assorted disconnects 35 pcs assorted nylon cable ties Assorted, 10' spools of UL 1426 boat cable 5 pcs (3"x3/8") 3:1 shrink ratio, colored heat shrink tubing Opens both sides
Item # 220020
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
217
Manage: Testers
600V
Patented
218
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage: Testers
Item # HSP5 Specifications DC Voltage: AC Voltage: DC Current: Resistance: Decibels: CAT Rating:
ERTEK INT
CM
C
LISTED
US
300V
CONFORMS TO UL STD. 61010-1 & 61010-031 CERTIFIED TO CAN/CSA STD C22.2 Nos. 61010-1 & 61010-031
Item # DSA540A Specifications DC Voltage AC Voltage DC Current AC Current Resistance Cont Buzzer CAT Rating Range 400/600V 400/600V 40/400 40400 400/4000 0600 Ohms II 600, III 300V AC Accuracy 1.5% 2% 3%8dgt (040A) 4%6dgt (40400A) 3%8dgt (040A) 4%6dgt (40400A) 2% Buzzer Sounds @ 100 Ohms or less Resolution 100mV 100mV 10mA 10mA 100m Overload Protection 720VAC/DC 720VAC/DC 480A 480A 300VAC/DC
600V
300V
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
219
Manage: Testers
Item # DSA1020TRMS Specifications DC Voltage AC Voltage DC Current AC Current Resistance Frequency Diode Test Cont Buzzer Capacitance Temperature CAT Rating Range 600mV/6/60/600V 6/60/600V 600/1000A 600/1000A 600/6K/60K/600K/ 6M/60M 10/100/1000/10K 3 0600 Ohms 40nF4000F 50 to 700C/ 58 to 1292F IV 600 Accuracy 1% 3dgt 1.5% 4dgt 1.5%rdg 5dgt 2%5dgt 1% 5dgt (600~6M) 5% 8dgt (6M~60M) 0.5%5dgt Buzzer Sounds @ 100 Ohms or less 2.5%20dgt (400nF40F) NA (40nF, 40F4000F) C 5/ F9 Resolution 100V 1mV 100mA 100mA 100m Overload Protection 720V AC/DC 720V AC/DC 1200A AC/DC 1200A AC/DC 600V AC/DC
Includes Carrying Case
600V
Range 200mV, 2V, 20V, 200V, 600V 200mV, 2V, 20V, 200V, 500V 200, 2K, 200k, 2M, 20M 1.5V (2V) -40F752F 3 3 III 600V
Accuracy 200mV & 600V (1.0%+5dgt) 2V 20V 200V (0.5%+5dgt) 500V (1.5%+5dgt) 2V 30V 200V (0.8%+5dgt) 200 20M (1.5%+2dgt) 2K 20K 200K 2M (1.0%+2dgt) 8%+5dgt
C
LISTED
US
600V
CONFORMS TO UL STD. 61010-1 & 61010-031 CERTIFIED TO CAN/CSA STD C22.2 Nos. 61010-1 & 61010-031
220
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Item # DM6450 Specifications DC Voltage AC Voltage DC Amps AC Amps Frequency Capacitance Resistance Diode Test Continuity CAT Rating Accuracy 400mV (0.8%+3dgt) 4V 40V 400V (0.8%+1dgt) 1000V (1.0%+3dgt) 4V, 40V, 400V, 750V 4V 40V 400V (1.0%+ 5dgt) 750V (1.2%+5dgt) 400A, 4000A, 40mA, 400A 4000A (1.0%+2dgt) 400mA, 4A, 10A 40mA 400mA (1.2%+3dgt) 4A 10A (1.5%+5dgt) 400uA, 4000uA, 40mA, 400A 4000A (1.2%+2dgt) 400mA, 4A, 10A 40mA 400mA (1.5%+3dgt) 4A 10A (2.0%+3dgt) 10Hz10MHz 0.1% +3dgt 40nF, 400nF, 4F, 40F, 100F 40nF (3%+10dgt) 400nF, 4F, 40F (3%+5dgt) 100F (4%+5dgt) 400, 4K, 40K, 400k, 4M, 40M 400O 4M (1.2%+2dgt) 4K 40K 400K (1.0%+2dgt) 40M (1.5%+2dgt) 3 3 III 600V, II 1000V
C
LISTED
ERTEK INT
CM
US
1000V
600V
CONFORMS TO UL STD. 61010-1 & 61010-031 CERTIFIED TO CAN/CSA STD C22.2 Nos. 61010-1 & 61010-031
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
221
Manage: Tools
Item # 700115
Cut/Strip/Crimp Tool
Precision ground cutters and stripping station, wide crimp range of insulated and non-insulated terminals Box crimp works with Ancor double crimp terminals, marking is embossed and paint filled Capacity: Crimps 2210 AWG / 0.35 mm2 insulated and non-insulated terminals, connectors and spark plug terminals in special cavities Strips insulation from 2210 AWG / 0.35 mm2 solid and stranded wires Cuts (4) 40/2 mm, (6) 32/4 mm, (8) 32/4.8 mm, (10) 32 / 6.4 mm and 1024/6.4 mm bolts Item # 701007
222
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Manage: Tools
Turbo Lite
Child resistant piezo electronic ignition system Powered by butane, inexpensive and readily available Flame temperature up to 2500F (1300C) Windproof and weatherproof flame Flame may be locked in on position Item # 702064
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
223
224
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Propel
Electric Propulsion _____________________________________ 226 Choose your Propulsion Kit & Throttle Control _____________ 227 Propulsion Kits ________________________________________ 228
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
225
226
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
36' / 11 m 6.0 kW
39' / 12 m 12.5 kW 43' / 13 m 10.0 kW 43' / 13 m 2x 5.0 kW 43' / 13 m 15.0 kW 46' / 14 m 12.0 kW 46' / 14 m 2x 6.0 kW 46' / 14 m 20.0 kW 49' / 15 m 15.0 kW 49' / 15 m 2x 7.5 kW
Propulsion kits Mastervolt supplies propulsion systems as kits. A kit includes: Motor and motor controls. Cables between motor and controls. Display/monitor, key, main switch and main fuse. Throttle controls The Mastervolt ControlMaster throttle controls were specifically designed for electric sailing and ensure that the speed of your vessel can be subtly and carefully controlled. Another important issue is an easily identifiable neutral gear. Your choice of throttle controls will depend on your preference. All our throttle controls were developed using corrosion-proof materials and are easily installed. The kits can be equipped with all available throttle controls.
Practical tips: Permanent Magnet (PM) motors are very compact and silent; Asynchronous motors are exceptionally quiet and have a very high torque. To find your most suitable batteries, go to mastervolt.us/ batteries A proper battery charger is essential for the maintenance and lifespan of your batteries. See mastervolt.us/chargers for assistance with your selection. A reliable battery monitor is a must. See mastervolt.us/ batterymonitor The number of sailing hours depends on your battery kit combined with the generated capacity. For six to eight hours sailing, you require 4.6 x kW motor capacity in kWh. Example: 4.6 x 3.5 kW = 16.1 kWh; this is the capacity required for six to eight hours sailing.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
227
DriveMaster
This compact, lightweight and powerful propeller drive is available in 11 models, ranging from 2.5 to 65 kW. Mastervolts DriveMasters can be easily built-in and come standard with all the essential components, with exception of the propeller and propeller shaft. With minimum maintenance and noise, the DriveMaster Ultra with its brushless technology is top of the DriveMaster line. Complete system All motor controllers are micro-processor controlled and secured against short circuiting, overload and incorrect polarity. The controller constantly monitors the entire system and adjusts power where necessary. The display is connected to the controller, and the motor is protected by an aluminium/stainless steel hood with an integrated cooling fan.
Type DriveMaster 2.5 DriveMaster 3.6 DriveMaster 5 DriveMaster 3.5 Ultra** DriveMaster 5 Ultra** DriveMaster 7.5 Ultra** DriveMaster 10 Ultra** DriveMaster 16 Ultra** DriveMaster 20 Ultra**
Capacity* 2.5 kW 3.6 kW 5.0 kW 3.5 kW 5.0 kW 7.5 kW 10.0 kW 16.0 kW 20.0 kW
Motor PM PM PM asynchronous asynchronous asynchronous asynchronous asynchronous asynchronous synchronous synchronous synchronous
Voltage Max. RPM technology regulator 24V 1100 36V 48V 48V 48V 48V 48V 96V 96V 180V 230V 300V 1600 1050 1450 1450 1450 1450 2500 1450 1450 2500 3000
Required battery capacity for 34 hrs 68 hrs sailing sailing 7 kWh 11.5 kWh 10 kWh 14 kWh 9.8 kWh 14 kWh 21 kWh 28 kWh 45 kWh 56 kWh 70 kWh 112 kWh 182 kWh 16.5 kWh 23.0 kWh 16.0 kWh 23.0 kWh 34.5 kWh 46.0 kWh 74.0 kWh 92.0 kWh 115.0 kWh 184.0 kWh 299.0 kWh
Item # 140100250 140100360 140100500 140300350 140300500 140300750 140301000 140301600 140302000
customer-specific product, please contact Mastervolt
* Supplied capacity. ** As an option, the DriveMaster Ultra can also be supplied with an adjustable motor support.
For a complete overview of our propulsion solutions and detailed specifications, see mastervolt.us/e-propulsion
228
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
PodMaster
Mastervolts ideal solution for motor or sailyachts is installed under the hull to save space and minimize sound and vibrations. Enjoy the sound of silence with one of the 12 available PodMasters, ranging from 2 to 10 kW, including seven steerable models and two heavy-duty versions for professional applications. Solid motor for minimal resistance The PodMaster is made of seawater-proof aluminium and given six layers of epoxy coating for extra protection. The heavy duty Professional models have a steel housing for extra durability. Its shape has been designed to ensure minimal resistance and optimize the propeller water flow. Depending on the model, the bulb contains an ultra-modern, sensor-free, 3-phase permanent magnet synchronised motor or a highly efficient permanent magnet DC motor. The motor, bearings and plugs were designed for professional use and guarantee years of sailing enjoyment and minimum maintenance. The PodMaster models are equipped with a suitable propeller, while the Professional models come without a propeller to allow perfect matching with various boat hulls. The shaft and tail fin were develop to minimise resistance and can be used as rudder for the steerable PodMaster models. To allow installation or use in limited drafts, the PodMaster can be fitted with a stainless steel anti-cavitation plate. Its high capacity and exceptional efficiency ensure that virtually PodMaster Professional the entire capacity is transferred to the propeller. PodMaster
PodMaster Steerable
Type PodMaster 2.0* PodMaster 2.5* PodMaster 4.2 PodMaster 6.5 PodMaster 10 PodMaster 2 Steerable** PodMaster 2.5 Steerable** PodMaster 4.2 Steerable** PodMaster 6.5 Steerable** PodMaster 10 Steerable** PodMaster 10 Professional***
Capacity 2.0 kW 2.5 kW 4.2 kW 6.5 kW 10.0 kW 2.0 kW 2.5 kW 4.2 kW 6.5 kW 10.0 kW 10.0 kW
Voltage Max. RPM technology regulator 24V 1800 36V 48V 48V 48V 24V 36V 48V 48V 48V 48V 48V 1800 1500 1500 1800 1800 2000 1500 1500 1800 950 1050
Required battery capacity for 34 hrs 68 hrs sailing sailing 5.6 kWh 9.2 kWh 7.0 kWh 11.8 kWh 18.2 kWh 28.0 kWh 5.6 kWh 7.0 kWh 11.8 kWh 18.2 kWh 28.0 kWh 18.2 kWh 28.0 kWh 11.5 kWh 19.3 kWh 30.0 kWh 46.0 kWh 9.2 kWh 11.5 kWh 19.3 kWh 30.0 kWh 46.0 kWh 30.0 kWh 46.0 kWh
Item # 140600200 140600250 140600420 140600650 140601050 140700200 140700250 140700420 140700650 140701050 141100650 141101000
* Delivered with fixed propeller, also available with folding propeller. ** This PodMaster model is also as Sterndrive available. *** Supplied without propeller.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
229
SailMaster
As the name indicates, this propulsion solution is specifically for sailyachts. The SailMaster asynchronous propulsion systems were developed for application with the standard saildrive propulsions from, for instance, Selva. With a very low resistance, the systems are delivered with a capacity of 5 or 7.5 kW at 48V. The standard delay in the saildrive causes the propeller to run relatively slowly: This allows for a larger propeller with increased thrust and efficiency, while also compensating for any transfer loss and minimizing vibrations. Although the installation inside the vessel means there is some audible sound, it is nothing compared to the noise of a normal diesel engine. Enjoy the peace
Required battery capacity for 34 hrs sailing 68 hrs sailing Item #* 7.0 kWh 14.0 kWh 140500500 9.8 kWh 19.6 kWh 140500750
230
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
HybridMaster
The HybridMaster is Mastervolts solution for hybrid propulsion: combining the advantages of electric propulsion with the sailing radius of a diesel engine. The HybridMaster series has an electric power rating ranging from 3.5 to 10 kW, allowing them to be combined with diesel engines of up to 150 hp. When sailing electrically, the HybridMaster gets its energy from the batteries. When sailing on the motor, the batteries are recharged up to a maximum of 150A. With the Mastervolt HybridMaster you can enjoy the best of both worlds. The HybridMaster is universally applicable and can be installed parallel to the propeller shaft. The gear ratio between the rpm of the electric motor and the propeller shaft can be adapted, which is crucial as it ensures that the electric propulsion is optimally adjusted to the existing propeller and motor. The HybridMaster Ultra is the top end of the line, using completely silent and maintenance-free brushless asynchronous motor technology.
Type HybridMaster 4.8 HybridMaster 9.6 HybridMaster 3.5 Ultra HybridMaster 5 Ultra HybridMaster 7.5 Ultra HybridMaster 10 Ultra
Voltage regulator Item # 48V 140103000 48V 48V 48V 48V 48V 140104000 140320350 140320500 140320750 140321000
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
231
232
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories
Wiper Motors __________________________________________ 234 Wiper Arms ___________________________________________ 241 Wiper Blades__________________________________________ 245 Horns ________________________________________________ 248 Compact Horns _______________________________________ 250 Trumpet Horns ________________________________________ 252 Surface Mount Horns___________________________________ 255 Wireless Remote Spot Light _____________________________ 257 Beamer Remote Control Halogen Spot _________________ 258 Beamer Remote Control Halogen Spot/Flood ____________ 259 Stainless Steel Spot/Floods & Deck Lamps________________ 260 Deck Lamps & Spotlight Accessories ____________________ 261 Lamps _______________________________________________ 262 Ventilation Basics ______________________________________ 268 Solar Vents____________________________________________ 270 Solar & Cowl Vents _____________________________________ 271 Clam Vents & Deck Plates ______________________________ 272 Fans _________________________________________________ 273
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
233
Wiper Motors
The motor choice is based primarily on the size of the windshield and where the motor is to be installed, either in an exterior or interior location. Marinco motors are split into three categories, Standard, Heavy-Duty, and Heavy-Duty Plus, with the categories being defined by the power range of the motors in those categories. Within the three categories, there are motors designed for interior or protected installations, and motors designed for exterior installations. With the addition of the 3.0 motor, we offer wiper motors for all windshield sizes up to 45", which could be covered by a 30" arm and 30" blade combination, driven by a 3.0 motor. The Standard motor category includes the STD, WMW, and 500, which are all designed for light duty use, defined as being able to drive a 14" arm and a 14" blade. The differences in the motors relate to their casings and the appropriate installation applications. The STD is designed to be used in interior or well protected locations. The WMW, with its chrome-plated brass outer housing, provides protection for exterior installations that have some protection. The 500 motor, with its thermoplastic, watertight housing, is ideal for any light-duty, external installation where the motor is constantly exposed to the elements. When coverage of a larger windshield is required, Marinco offers the Heavy-Duty motors, which are capable of driving a wide range of arm and blade sizes, up to a 26" x 26" Deluxe arm and blade combination, which would cover windshields up to 39" with the 2.5 motor. The MRV is built for interior or well-protected locations, and has the power to pull a 22" X 22" Deluxe arm and blade combination. It has two speeds, with adjustable sweep set and adjustable parking. The 1000 motor can pull up to a 16" x 16" Deluxe arm and blade combination. While not as powerful as the MRV, it is waterproof, with the high-density thermoplastic housing offering complete protection from the elements. The 1000 motor is a one-speed motor, with adjustable park and adjustable sweep settings. The third motor in this category, the 1.5 motor has the power to pull a 22" x 22" Deluxe arm and blade combination like the MRV, but is waterproof and built for exposed installations. The 1.5 motor has a powder-coated aluminum base and housing for greater operating efficiency and durability, with two-speed operation, and adjustable park and sweep sets. The fourth motor is the 2.5 motor and has the same features as the 1.5 motor (waterproof, powder-coated aluminum housing, etc.), with the added power to drive a longer (26") Deluxe arm and blade combination. The 3.0 motor is the motor that makes up the Heavy-Duty Plus category. A wiper motor for internal installations, the 3.0 motor has an external linkage shaft drive that gives it the power and torque to drive a 30" Premier pantographic arm and Premier blade combination. See the following catalog pages for a full set of specifications on this, and all of the other wiper motors.
3.0
2.5
1.5
2 speed
1000
single
MRV
12 & 24V
2 speed
500
12V
single
WMW
12V
single
14" Deluxe
2.5"
STD
12V
single
14" Deluxe
2.5" 3.5"
Factory preset: corrosion proof 80 or 110 aluminum alloy Adjustable: 80 or 110 case
234
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
7.79 (197.9mm)
7.79 (197.9mm)
4.60 (117.0mm) .25 (6.5mm)
2.5" Shaft
1.96 (50.0mm)
4.32 (109.9mm)
2.68 (68.3mm)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
235
1.5" Shaft
.53 (13.5mm)
m)
236
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
3.13 (79.6mm)
.26 (6.5mm)
3.13 (79.6mm)
W = 4.25 (108mm)
D = 3.02 (76.8mm)
1.5" Shaft
.53 (13.5mm)
(70.28mm)
W = 3.98 (101.0mm)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
2.87 (73.0mm)
.20 (5mm)
2.87 (73.0mm)
.20 (5mm)
D = 2.77 (70.28mm)
L = 7.76 (197.0mm)
237
1.5" Shaft
m)
W = 3.3 (83.8mm)
238
2.35 (59.69mm)
2.35 (59.69mm)
.20 (5mm)
L = 6.63 (168.4mm)
toll free 800.307.6702
.20 (5mm)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
1.47 (37.38mm)
2.08 (52.8mm)
1.5" Shaft
3.96 (100.8mm)
1.47 (37.38mm)
2.08 (52.8mm)
1.47 (37.38mm)
6.06 (154.0mm)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
239
m)
240
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Wiper Arms
Wiper arms are available in Standard, Deluxe, and Premier styles and the primary construction material in all wiper arms is stainless steel. Standard arms are used with Standard blades and can only be used with the line of Standard motors, while the Deluxe arms are used on Standard and Heavy-Duty motors. When choosing arms (and blades) it is very important to use only the recommended lengths for the motor that you are using. The arms are available in a wide range of sizes, in both black and stainless steel finish, and regular and pantographic models. Pantographic arms use a set of two arms joined together to give a flatter and somewhat wider sweep pattern. The Deluxe arms are offered in either with a polished stainless steel finish or a black powder-coated finish. Premier arms are the top of the line product in this category, utilizing heavy-duty stainless steel tubing and components, and they can only be used with the Heavy Duty and Heavy Duty Plus motors. Premier arms come in adjustable length sizes, ranging from 10" to 30", in both regular and pantographic versions. The longer length Premier arms (25" 30" long) have been designed for added strength and have a tapered wiper shaft fitting made especially to fit the larger, more powerful 3.0 wiper motor. These arms also have a saddle style tip for a stronger connection with the longer length Premier blades (26", 28", and 30" lengths). Premier arms are also available as wet arm versions, with the water hose and sprayer nozzle built into the wiper arm. All that is needed is a water delivery system that the arm can be tied into. For those wanting a windshield washer system for the Deluxe arms, there is a complete washer kit system that is made especially to fit the Deluxe arms.
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
241
Wet/ Length Dry (adjustable) Color dry wet 25"30" 26"30" 25"30" 26"30"
Material Item #
3.0 4 4 4 4
2.5
1.5
1000
MRV 4 4 4 4
max 20"
stainless stainless 33088 stainless stainless 33096 stainless stainless 33088W stainless stainless 33096W
pantographic dry pantographic dry pantographic dry pantographic wet pantographic wet pantographic wet Deluxe Adjustable single single single single single single dry dry dry dry dry dry
4
max 20" 80"
4 4 4 4 4
max 22"
4
max 18" 80 max 16" @ 110
Premier Plus Stainless Steel Adjustable Single and Pantographic Wiper Arm
Heavy-duty component design for use with the 3.0 wiper motor Stainless steel and chrome-plated die cast construction Motor shaft mount with notched teeth and tapered design for secure operation Features Articulating/ Bend Back design that locks arm in upright position for windshield cleaning
pantographic adjusts 26" to 30" Style single Length Wet/Dry (adjustable) dry 25"30" 26"30" Color Material Item # stainless stainless 33088 stainless stainless 33096 OEM # 33188 33196
pantographic dry
242
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Single
Pantographic
Style single
pantographic wet
Pantographic wiper arms will only function properly with wiper motor sweep angles 80 or less
Single
Pantographic Length Wet/Dry (adjustable) dry 10"15" dry dry 15"20" 20"25" 12"17" 17"22" 22"26"
Color Material Item # stainless stainless 33082 stainless stainless 33084 stainless stainless 33086 stainless stainless 33090 stainless stainless 33092 stainless stainless 33094
Pantographic wiper arms will only function properly with wiper motor sweep angles 80 or less
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
243
Color Material Item # stainless stainless 33084W stainless stainless 33086W stainless stainless 33090W stainless stainless 33092W stainless stainless
Pantographic wiper arms will only function properly with wiper motor sweep angles 80 or less
Color Material Item # stainless stainless 33006A stainless stainless 33007A stainless stainless 33010A black black black stainless 33012A stainless 33014A stainless 33070A
Length Style Wet/Dry (adjustable) pantographic dry 12"17" pantographic dry 17"22"
244
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Premier Plus Blades Length 26" OEM # 33126S Premier Plus Wiper Arms Single Arm Wet Pantograph Arm Dry Wet Dry 33088, 33188 33096, 33196 4 33088W, 33188W 4 4 33096W, 33196W 4 4 4 4 4 28"
Premier Blades Color/Material Stainless/Stainless Length 20" Item # 33021S 33022S 33024S 33021B 33022B 33004 OEM # 33121S 33122S 33124S 33121B 33122B 33104 Premier Wiper Arms Single Arm 4 4 4 80 only 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 33084, 33184, 33084W, 33184W 4 33086, 33186, 33086W, 33186W Pantograph Arm 4 33092, 33192, 33092W, 33192W 4 33094, 33194, 33094W, 33194W Deluxe Wiper Arms Single Arm 33007A 33107A 33010A 33110A 33012A 33112A 33014 330114A 33070A 33170A Pantograph Arm 33032A 33132A 33037A 33137A 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 80 only 33006A 33106A 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 80 33090, 33190, 33090W, 33190W only 33082, 33182 4 4 4 4 4 4 4 4 4 80 only 4 4 4 4 4 80 only 4 4 33105 33005 33015 33115 22" 24" 20" 22" 11.5" 14" 16" Black/ Stainless Stainless/Stainless 18" 33016 33116
Deluxe Blades
Standard Blades Black 20" 33017 33117 4 4 4 80 only 4 4 4 4 80 only 4 4 4 4 4 4 4 22" 33022 24" 33023 26" 33024 12" 14" 16"
18"
20"
22"
24"
80 only
80 only
80 only
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
4 4 4 4 4 4 4
4 4 4 4 4 4 4
4 4 4 4 4 4 4
Pantographic wiper arms will only function properly with wiper motor sweep angles 80 or less
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Standard, Premier, and Deluxe wiper blades are offered in different sizes and styles to fit all of the different types of wiper arms. Standard styles have plastic frame construction and marine grade rubber squeegees. Premier and Deluxe styles have stainless steel frame construction and high-end silicone rubber squeegees. These two styles have multiple frame construction, allowing for equal pressure of the entire length of the blade and silicone rubber squeegees that are durable and crate a smoother wiping motion. In addition, longer length Premier blades (26", 28", and 30") are specifically designed with a saddle style attachment for the longer length Premier arms. (25"30"). For maximum performance of all blade styles, replacement of wiper blades is recommended every 6 months.
Color/Material Stainless/Stainless
Black/Stainless
30"
26"
28"
30"
33130S
33126B
245
Wiper Blades
246
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
247
Accessories: Horns
Marinco Horns
Marinco is the leading supplier of horns to the marine industry, with over fifty years of experience in designing and manufacturing sound devices specifically for use in harsh marine environments. Stainless steel is used for all critical components such as trumpets, motor cover, diaphragms, and assembly and mounting hardware. In the case of the XLP trumpet horns, the horn is given extra protection through the complete over-molding of the internal motor cover housing. It is this extra process that provides the added protection needed to back up the five-year warranty. Marinco offers a complete line of marine horn products designed to meet almost any need, including electric and air trumpet horns, compact horns, electric and air below deck horns, and a comprehensive line of drop-in horns with a wide assortment of grill options. After developing the first below deck horn for the marine industry in the late 1980s, the offering of that product line has continued to expand. The latest addition is the H Horn Phase II, which is the loudest drop-in horn available today. Notes: Marinco electric horns meet the American Boat & Yacht Council (ABYC) Regulation #A23 for boats up to 12 meters. All Marinco air horns meet the U.S. Coast Guards C.O.L.R.E.G.S. and U.S. Inland Navigation Rules, Annex III Regulations for boats up to 20 meters. Marinco horns are listed in the National Marine Manufacturers Association (NMMA) Certification Program type accepted list All Marinco horns are listed for boats up to 12 meters and all Marinco air horns are listed for boats up to 20 meters. Horn motors and compressors are 12 volt unless otherwise indicated. Marinco horns are set at a lower frequency to provide greater range as the sound travels across the water. Horns should be mounted facing forward whenever possible. The NMMA Certification Program requires this for boats 39' or longer.
Notice Concerning Marine Horns, CE, and Electromagnetic Interference In order to operate, an electric horn rapidly makes and breaks an electric circuit. This operation creates electromagnetic disturbance, which may cause electrical noise in communications equipment. Because a horn is only used temporarily, any interference in electronic equipment is stopped when the horn is turned off. The International Marine Certification Institute (IMCI), which certifies boats to the European Community Regulations (CE), has determined that boats using electric horns can comply with CE requirements on electromagnetic compatibility provided the above message is given to the boat owners in their manual.
248
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories: Horns
Marinco, the inventor of the first below deck horns, offers a full line of below deck horn products. Concealed horns utilize an upright horn installation and a large grill opening to offer greater sound volume. Drop-In Hidden Horns use a fabric lined grill for water-resistant installations. The concealed trumpet horns are all air horns and provide the maximum amount of sound available in a below deck horn installation. Important: Please note the space requirement dimensions on some of the below deck models to ensure there is adequate room on the interior of the mounting area to house the horn assembly. Concealed horn models require a minimum 45 mounting angle to ensure proper drainage.
Marincos Drop-In Hidden Horns combine a number of desired features into one unit including: Simple, drop-in installation Stylish snap-on grill with water-resistant fabric Authentic marine sound Easy aftermarket retrofit
Accessories | Horns
H Horn Phase II Drop-In Hidden Horn with Black and White Grills
Comes with both white ASA and black ABS screw-in grills Grills have water resistant fabric liners Easy installation: 2.75" diameter hole x 1" deep 12 volt, maximum amp draw: 4 amps New louder dB(A) rating: 111 at one meter Fundamental frequency: 37020Hz Mounts from the outside, grill screws on for easy install Easy retrofit
Item # 10080
11187
11194
11188
11196
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
249
Item # 10082
Item # 10079
OEM # 11095
250
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories | Horns
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
251
OEM # 11050
OEM # 11059
252
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Marincos FullBlast compressor driven air horns are the loudest and most complete line of 12V air horns available. All of our air horns produce sound levels ranging between 120 and 127dB, which means all of our air horns meet the ABYC and NMMA regulations for boats up to 20 meters/66 feet. Both 12 and 24 volt compressors are CE listed.
Accessories | Horns
12 Volt 24 Volt
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
253
Air Compressor
Replacement compressor fits all AFI Air Horns Dimensions: 2.625" D x 5" L Includes mounting bracket Maximum amp draw: 20 amps, Produces 911 PSI
254
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories | Horns
Item # 10010
Item # 10011
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
255
Item # 10023
Item # 10036
256
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories | Lighting
Bulb: Power (Input voltage): Current draw (idle/in use): Peak Beam Intensity: Peak Beam Distance: Lux @ 82' (25 m): Coverage at 82' (25 m): Rotation: Tilt: Wireless range: Dimensions: Weight: Housing material: Lens material: operating temp range: IP Rating:
100 Watt, H3 Halogen 12V or 24V 0.03 amps / 7.0 amps 210,000 Cp 3,000 ft (917 m) 226 Lux 180 sq ft (15'H x 12'W) (16.7 sq m [4.6 m x 3.6 m]) 370 (built in limit stops) 120 Tilt (75 up & 45 down) 200 ft (65 m) 7.5"W x 7.5"H x 9.25"D (19cm x19cm x 23.5cm) 3.30 lbs (1.5 kg) UV resistant PC/ASA UV resistant Lexan 5F113F (-15C45C) IP56
Description 12/24 Volt, 100 Watt 12/24 Volt, 100 Watt 12/24 Volt, 100 Watt 12 Volt, 100 Watt 12 Volt, 100 Watt 12 Volt, 100 Watt 24 Volt, 100 Watt 24 Volt, 100 Watt 24 Volt, 100 Watt Replacement Bulbs Description 12 Volt, H3 Halogen 24 Volt, H3 Halogen
Color white black chrome white black chrome white black chrome
Remote Options
Remote Specifications Power Current draw (idle / in use) Wireless range Estimated battery life Dimensions Weight Housing material Button material Operating temp range IP Rating SPRL-2 Included Wireless Bridge Remote 12 or 24 volt (hard wired) negligible 200 ft (65m) 3.5"Wx2.25"Hx.75"D 88x57x19 mm 2.12 oz (60g) UV resistant PC/ASA Silicone (glow in the dark) 5F113F (-15C45C) IP56 SPRL-1 (optional) Hand Held Bridge Remote CR2540 button cell battery negligible 200 ft (65m) > 40 hours (continuous use) 2.0"Wx3.78"Hx1"D 51x96x25 mm 2.82 oz (80g) UV resistant PC/ASA Silicone (glow in the dark) 5F113F (-15C45C) IP56 SPRL-3 (optional) Wired Bridge Remote 12 or 24 volt (hard wired) negligible 3.5"Wx2.25"Hx.75"D 88x57x19 mm 2.12 oz (60g) UV resistant PC/ASA Silicone (glow in the dark) 5F113F (-15C45C) IP56
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
257
Item # 501A
Item # 500A Illuminates objects up to a mile away Marine grade construction One year warranty Light can be directed manually without damaging motors 8 amps, up to 10 on start 12V Halogen Replaceable 100 watt Halogen bulb 10.375" H x 7.375" W x 9.25" D 5.75" W x 6.25" D 3.75 Lbs.
Item # 502-2
Replacement Bulb
12V, 100 Watt Halogen Item # 729493
7-3/8" 187mm
355 Rotation
7-3/8" 187mm
40
5-1/2" 139mm
35
10-3/8" 263mm
5-3/4" 146mm
258
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories | Lighting
Replacement Bulb
12V, Halogen Item # 729494 Illuminates objects up to a mile away Marine grade construction One-year warranty Light can be directed manually without damaging motors 100 watt spotlight with 55 watt floodlight Includes 15 ft. wiring harness 8 amps, up to 10 on start 12V Halogen Replaceable Halogen bulb 10.375" H x 7.375" W x 9.25" D 5.75" W x 6.25" D 3.75 Lbs.
Item # 505
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
259
70
Remote control, joystick operation 316 stainless steel base, 304 stainless steel head One year warranty Dual station option available Light can be directed manually without damaging motors
Replacement Bulb
12V Incandescent Item # 22014-P
Spot kit includes joystick control and 15 wiring cable with easy to install plug ends
Replacement Bulb
12V Incandescent Item # P-14302
260
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories | Lighting
Item # ML-005NWW
Beamer Parts and Accessories Model Number 500, 500A 501, 501A 502, 502A 502-1 502-2 503, 503A 503-1 503-2 Control Panel 729823-P 729825 729827-P U-3605 729489 729829-P U-3606 22208-24 Dual Station Control Kit 729823-P 729825 729828-P 729488 729489 729830-P 729491 729492 Replacement Bulb Kit 729493 729493 729493 729493 729493 729494 729494 729494 Extension Cable Kit 729528 729528 729528 729528 729528 729528 Wires in Cable 1 Wireless 5 5 5 6 6 6
Stainless Steel Spot/Flood Parts and Accessories Model Number 22040A 22041A 22044 22045 Oval Panel 22240 22240 22240 22240 Rectangular Control 22208A 22208A 22208A 22208A Dual Station Control Kit 22218A 22218A 22218A 22218A Replacement Bulb Kit 22014-P 22014-P P-14302 P-14302
M-100 Remote Halogen Spot Parts and Accessories Model Number 22200 22201 Extension Cables Length 25 Ft. 35 Ft. Male to Male 22011A-P 22012A-P Male to Female 22011MA-P 22012MA-P Joystick Control 22209 22209 Dual Station Control Kit 22219A 22219A Replacement Bulb Kit 22230-P 22230-P
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
261
Accessories: Lamps
Lamps
Heavy duty glass envelope for break resistance. Nickel-plated brass bases prevent corrosion while insuring a positive point-of-contact. Filaments, with rough service design, permit hours of reliable burning. Not rated for navigation. A Qty/ Pkg 1 1
1 LED
2 LEDs
262
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories: Lamps
General Lamps
Figure Letter K L System Design Design Design Line # Trade # Volts Volts Amps Watts CP 14 4.80 4.80 .62 3.00 4.06 15 16 17 M N O P Q R S 18 19 20 21 22 23 24 25 26 27 28 29 T 30 31 32 33 34 35 36 U 37 1004 82 68 90 1224 94 1076 1142 1142R 1176 1204 1228 1003 57 1816 1416 906 53 194 168 12.00 12.00 12.00 12.00 12.00 12.00 12 .00 12.00 12.00 12.00 12.00 6.00 12.00 12.00 32.00 12.00 12.00 12.00 12.00 12.00 24.00 32.00 12.00 14.00 14.00 12.80 13.00 14.40 14.00 14.00 13.00 12.80 13.50 12.80 6.50 13.50 13.00 34.00 12.80 12.80 12.80 12.80 12.8/14 28.00 34.00 12.80 .27 .35 1.0 .69 .12 .35 .24 .33 .80 2.08 .94 1.02 .59 .58 .16 1.04 1.80 1.44 1.44 .71 .45 .94 3.80 4.90 12.8 9.00 1.70 5.0 3.40 4.30 10.20 25.00 12.00 6.60 8.00 7.50 5.10 13.30 23.00 18.40 18.40 19.90 15.30 12.00 2.00 3.00 12.00 6.00 1.00 3.0 2.00 3.00 8.00 30.00 15.00 6.00 4.00 6.00 3.80 15.00 32.00 21.00 21.00 21/6 21.00 15.00 15.00 200 500 5000 750 500 700 200 1000 1000 300/1500 400 150 200 500 1000 1000 1000 1000 Life 1500 1500 Qty/ Pkg 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 Item # 521128 520194 520168 520912 520906 520053 521126 520057 521816 521416 521159 521004 520082 520068 520090 521224 520094 521076 521142 521140 521176 521204 521228 521003
Accessories | Lighting
Wedge Base L
Wedge Base M
1.34/.39 17.20
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
263
Accessories: Lamps
General Lamps
Figure Letter V W System Design Design Design Line # Trade # Volts Volts Amps Watts CP 38 97 12.00 13.50 .69 9.30 4.00 39 40 41 42 X Y 43 44 45 46 47 Z 48 67 1383 93 1141 1156 1034 1157 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 24.00 120.00 13.50 13.00 12.80 12.80 12.80 12.8 12.8/14 13.50 24.00 120.00 .59 1.54 1.04 1.44 2.10 1.8 2.1/.59 .83 .41 .25 8.00 20.00 13.30 18.40 26.90 23/8.2 27/8 10.00 10.00 30.00 12.00 12.00 20.00 4.00 300 15.00 21.00 32.00 32/3 700 500 1200 200/5000 200/5000 1000 Life 5000 5000 Qty/ Pkg 2 2 1 2 2 2 2 2 1 1 1 Double Contact Index Base Y Item # 520097 520067 521383 520093 521141 521156 521034 521157 521158 521162 521164 Double Contact Bayonet Base Z Single Contact Bayonet Base V
AA
AB
AC
AD
AE
AF
AG
264
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories: Lamps
Accessories | Lighting
AG
100A17/12 12.00
AH
Navigation Lamps
Figure Letter AJ AK System Design Design Design Line # Volts Volts Amps Watts CP 92 12.00 12.00 2.50 30.00 26.00 93 95 96 97 24.00 12.00 24.00 24.00 24.00 12.00 24.00 24.00 1.67 2.08 1.04 .42 40.00 25.00 25.00 10.00 28.00 24.00 24.00 12.00 Life 1200 1200 1200 1200 1200 Qty/ Pkg Item # 1 529300 1 1 1 1 521166 529340 529341 529344
AI
AJ
Fluorescent Tubes
Figure Letter AL Line # Trade # 98 F8T5/CW 99 100 Volts Watts 13.5 8.00 15.00 13.00 M.O.L. 11.3" 18" 20.86" M.O.D. .5" 1.0" .5" Life 7500 7500 7500 Qty/ Pkg Item # 2 529405 2 2 529406 529407
AL
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
265
Accessories: Lamps
AM
AN
AO
.4"
1.33"
266
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories: Lamps
Accessories | Lighting
This lamp life nomograph shows the Voltage relationship between voltage, current, candle power and life. Each lamp has % of rated a design voltage as well as a nominal Current operating voltage. This allows the % of rated designer of the lamp to tailor the life/ Candle output/current draw to meet specific Power needs, within certain industry standards. We have chosen to emphasize life and % of rated brightness. The rated life is based on the Life average life of 50% of the lamps tested under laboratory conditions no vibration, stable voltage, room temperature, and in a vertical position. Any other condition will adversely affect lamp life. Example: To find the effect of under or over voltage on life, current draw and candle power, read in a horizontal line under % of rated voltage. Thus, a #90 bulb rated at 13V but operating at 14.70v (113% of rated voltage a high charge rate) would have 107% of rated current draw, 155% of rated candle power, but would only last 23% of its rated life.
% of rated
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
267
* For effective maintenance ventilation, one vent assumes there will be access for air to get into the cabin (i.e., cowl vent, clamshell vent or louvered panel)
To Specifically Calculate Your Boats Air Volume, Use This Simple Formula: A x B x C x 70% = Boat Interior Volume A Dimension is the interior length (excluding cockpit) B Dimension is the boat width C Dimension is the average interior height
268
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Installation
All Marinco ventilation products include clear, easy-to-understand installation instructions. These instructions address all of the key factors of a professional installation, such as: Proper hole measurement and cutting procedures Proper deck plate installation Use of sealants to waterproof your vent installation Installing vents in hatches Installing vents in cambered or slightly curved decks Use of interior trim rings to dress up the cabin The high quality level of Marinco Ventilation products must be combined with a sound installation to guarantee that your vent performs in all conditions. Marinco will make sure that your installation will be easy and successful so that you can enjoy the benefits of installation for a long time to come. Marinco Ventilation Installation Systems Snap-In Deck Plate Installation The 12 volt vent, 12 volt combo vent and cowl vents use the Marinco Snap-In deck plate system. The Snap-In system allows the easy exchange of any Snap-In part for upgrading or convenience, as well as the use of a Snap-In cover that completely seals the deck plate making it water tight. Direct-To-Deck Installation The Day/Night Plus, MiniVent 1000 and AirVent 500 are designed to be installed directly to the deck without the requirement for a deck plate. All of these vent systems have built-in shut-off dampers that operate from below.
Accessories | Ventilation
06a-Sanding.ilp
OR
PROCESS RUBINE
DECK PLATE DECK PLASTIC INTERIOR TRIM RING DECORATIVE TEAK TRIM RING
BLUE RED YELLOW PROTECTIVE Snap-In deck plates are used to install the 12 Volt RING Vents, 12 Volt Combo Vents and Cowl Vents only. Models with threaded deck plates have different installation requirements. Please consult installation instructions for these models.
HATCH 109
BLACK
Day/Night Plus
Operation Day
Solar 1.75"
Cubic Feet of Air 1000 ft3/hour 20 m3 24,400 ft3/day Rechargeable 672 m3 Battery Power Night 600 ft3/hour 17 m3 16,800 ft3/day Rechargeable 408 m3 Battery Power 700 ft3/hour 20 m3 5,600 ft3/day 160 m3
Intake
Exhaust
Fan
Fan
3" 76 mm
3-3/4"
None
(Direct to Deck Mounting)
Solar 1"
Fan
MiniVent 1000
3" 76 mm
3-3/4"
None
(Direct to Deck Mounting)
Passive
AirVent 500
3" 76 mm
3-3/4"
None
(Direct to Deck Mounting)
Passive
Cowl Vents
4-3/4"
Snap-In
(6" Outer Diameter)
3-3/4"
Snap-In
(5" Outer Diameter)
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
269
Replacement NiMh Nickel Metal Hybrid Battery for Day/Night Plus Vents
High capacity C-cell battery 1.2 volts, 2.0 amp-hours Replacement battery for current Day/Night Plus vents, as well as, older model PowerVent 3000 and Day/Night 2000 Vents Average life: 35 years Environmentally friendly Item # N20790
270
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories | Ventilation
Cowl Vents
Cowl Vents are available in both low profile and standard height contours. These vents are a perfect air intake supplement to solar ventilation, and are also commonly used as a bilge ventilating system with or without a mechanical blower. Marinco was the first supplier of soft, durable PVC vents that are flexible and safe. For interchangeability, Marinco 4" cowl vent models fit into the same 4" Snap-In deck plates used by the Combo and 12V vents (3" or 4" sizes). Soft and durable PVC construction returns to original shape if stepped on Safer than metal cowl vents prevents injury and resists snagging lines Snap-In vents include deck plate and cover 4" models interchangeable with Marinco Combo and 12V Vent 4" snap-in deck plates Marinco adapter accessories make installing below-deck duct hose easy
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
271
DECK PLATE
BILGE HOSE
272
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Accessories: Fans
Marine Fan
120 adjustable oscillating fan Can be set for stationary operation Mount on wall, ceiling or dash Built-in on/off switch Installation hardware included 12 volt DC operation, 1.2 amp draw Translucent fan blades 7.5" vinyl-coated fan guard Mounting base dimensions: 3.375" L x 1.5" W Stands 8" from mounting surface
Accessories | Ventilation
Item # 900
Folding Fan
Fan folds out of the way when not in use Rotating louver directs air flow Mount on wall, ceiling or dash Built-in on/off switch Installation hardware included 12 volt DC operation, .8 amp draw Dimensions: 6.75" W x 5.06" H x 1.93" D
Item # 902
Personal Fan
180 adjustable swivel fan Mount on wall, ceiling or dash Built-in on/off switch Installation hardware included 12 volt DC operation Compact design installs anywhere Great for windshield defogging Base Dimensions: 3" diameter Stands 5" from mounting surface
Item # 903-5
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
273
Index
100010 ________________ 193 10001 _________________ 256 100050 ________________ 193 1000-6W_______________ 142 1000-ACSM ____________ 142 1000-AM10 ____________ 142 1000-AM20 ____________ 142 1000-AM50 ____________ 142 1000-DCSM ____________ 142 1000-VM-12V __________ 142 1000-VM-24V __________ 142 10010 _________________ 255 100110 ________________ 193 10011 _________________ 255 10017XL _______________ 254 100210 ________________ 193 10023 _________________ 256 10028XLP _____________ 254 10029XLP _____________ 254 100310 ________________ 193 100319 ________________ 199 10031 _________________ 251 100320 ________________ 199 10035 _________________ 255 10036 _________________ 256 100410 ________________ 193 100510 ________________ 193 100610 ________________ 193 100710 ________________ 193 10079 _________________ 250 10080 _________________ 249 100810 ________________ 193 10082 _________________ 250 100850 ________________ 193 100910 ________________ 193 10098 _________________ 255 10099 _________________ 255 100eL __________________ 23 100R ___________________ 23 101010 ________________ 193 10102 _________________ 254 10104 _____________ 253, 254
10105 _________________ 253 10106 _________________ 254 10107 _________________ 253 10108 _________________ 253 10121 _________________ 253 10122 _________________ 254 101910 ________________ 193 102010 ________________ 193 102025 ________________ 193 102050 ________________ 193 102099 ________________ 193 102150 ________________ 193 102164 _________________ 27 102167 _________________ 27 102182 _________________ 24 102210 ________________ 193 10224 _________________ 254 102250 ________________ 193 102310 ________________ 193 102350 ________________ 193 102410 ________________ 193 102510 ________________ 193 102610 ________________ 193 102710 ________________ 193 102810 ________________ 193 102825 ________________ 193 102850 ________________ 193 102899 ________________ 193 102910 ________________ 193 102999 ________________ 193 102N ___________________ 23 103010 ________________ 193 103099 ________________ 193 103910 ________________ 193 103eLN ________________ 23 103RN.oeM ____________ 23 103RNXPk ______________ 28 103RNX ________________ 28 103RN _________________ 23 104010 ________________ 193 104025 ________________ 193 104050 ________________ 193
104099 ________________ 193 104110 ________________ 193 104199 ________________ 193 104210 ________________ 193 104299 ________________ 193 104310 ________________ 193 104350 ________________ 193 104410 ________________ 193 104510 ________________ 193 104610 ________________ 193 104710 ________________ 193 104810 ________________ 193 104825 ________________ 193 104850 ________________ 193 104899 ________________ 193 104910 ________________ 193 104950 ________________ 193 104SPP-25.oeM _________ 19 104SPP-50.oeM _________ 19 104SPP_________________ 19 105010 ________________ 193 105099 ________________ 193 10524 _________________ 253 105SPP_________________ 19 106010 ________________ 193 106025 ________________ 193 106040 ________________ 193 106099 ________________ 193 106110 ________________ 193 106210 ________________ 193 10624 _________________ 254 106310 ________________ 193 106340 ________________ 193 106510 ________________ 193 106610 ________________ 193 106710 ________________ 193 106810 ________________ 193 106825 ________________ 193 106840 ________________ 193 106899 ________________ 193 106910 ________________ 193 106940 ________________ 193
107010 ________________ 193 108002 ________________ 193 108010 ________________ 193 108025 ________________ 193 108050 ________________ 193 108099 ________________ 193 108110 ________________ 193 108150 ________________ 193 108210 ________________ 193 108250 ________________ 193 108310 ________________ 193 108325 ________________ 193 108399 ________________ 193 108425 ________________ 193 108510 ________________ 193 108802 ________________ 193 108810 ________________ 193 108825 ________________ 193 108850 ________________ 193 108899 ________________ 193 108910 ________________ 193 108999 ________________ 193 109010 ________________ 193 109310 ________________ 193 109399 ________________ 193 10MSPPXP______________ 28 10MSPPX _______________ 28 11001 _________________ 256 1100-Bk-TS ____________ 143 1100-Bk _______________ 143 11017XLP _____________ 254 11018XLP _____________ 254 1101-Bk-TS ____________ 143 1101-Bk _______________ 143 11024 _________________ 251 11028XLP _____________ 254 11029XLP _____________ 254 11031 _________________ 251 11034 _________________ 251 11035 _________________ 255 11050 _________________ 252 11058 _________________ 252
274
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Index
11059 _________________ 252 11060 _________________ 252 11064 _________________ 252 11066 _________________ 252 11079 _________________ 250 11080 _________________ 249 11088 _________________ 251 11090 _________________ 251 11091 _________________ 251 11095 _________________ 250 11096 _________________ 249 11098 _________________ 255 11099 _________________ 255 110A ___________________ 20 110R ___________________ 23 111002 ________________ 194 111010 ________________ 194 111025 ________________ 194 111050 ________________ 194 11106 _________________ 254 11107 _________________ 253 111099 ________________ 194 11124 _________________ 251 111310 ________________ 194 111325 ________________ 194 111350 ________________ 194 111502 ________________ 194 111510 ________________ 194 111525 ________________ 194 111550 ________________ 194 111599 ________________ 194 11168 _________________ 251 111710 ________________ 194 111799 ________________ 194 11185 _________________ 250 11187 _________________ 249 11188 _________________ 249 11190 _________________ 251 111910 ________________ 194 11191 _________________ 251 11194 _________________ 249 11196 _________________ 249
111999 ________________ 194 111A ___________________ 20 112002 ________________ 194 112005 ________________ 194 112010 ________________ 194 112025 ________________ 194 112050 ________________ 194 112075 ________________ 194 11225 _________________ 251 11226 _________________ 251 112310 ________________ 194 112375 ________________ 194 112502 ________________ 194 112505 ________________ 194 112510 ________________ 194 112525 ________________ 194 112550 ________________ 194 112575 ________________ 194 112710 ________________ 194 112910 ________________ 194 112975 ________________ 194 113002 ________________ 194 113005 ________________ 194 113010 ________________ 194 113025 ________________ 194 113050 ________________ 194 113502 ________________ 194 113505 ________________ 194 113510 ________________ 194 113525 ________________ 194 113550 ________________ 194 113910 ________________ 194 113950 ________________ 194 114002 ________________ 194 114005 ________________ 194 114010 ________________ 194 114025 ________________ 194 114040 ________________ 194 114502 ________________ 194 114505 ________________ 194 114510 ________________ 194 114525 ________________ 194
114540 ________________ 194 114905 ________________ 194 114910 ________________ 194 114940 ________________ 194 115002 ________________ 194 115005 ________________ 194 115010 ________________ 194 115030 ________________ 194 115502 ________________ 194 115505 ________________ 194 115510 ________________ 194 115530 ________________ 194 115902 ________________ 194 115905 ________________ 194 115910 ________________ 194 115930 ________________ 194 115A ___________________ 20 116002 ________________ 194 116005 ________________ 194 116010 ________________ 194 116025 ________________ 194 116502 ________________ 194 116505 ________________ 194 116510 ________________ 194 116525 ________________ 194 116902 ________________ 194 116905 ________________ 194 116910 ________________ 194 116925 ________________ 194 117002 ________________ 194 117005 ________________ 194 117010 ________________ 194 117020 ________________ 194 117502 ________________ 194 117505 ________________ 194 117510 ________________ 194 117520 ________________ 194 117902 ________________ 194 117905 ________________ 194 117910 ________________ 194 117920 ________________ 194 117A ___________________ 20
Index
118005 ________________ 194 118010 ________________ 194 118015 ________________ 194 118502 ________________ 194 118505 ________________ 194 118510 ________________ 194 118515 ________________ 194 118905 ________________ 194 118A ___________________ 20 119002 ________________ 194 119005 ________________ 194 119010 ________________ 194 119502 ________________ 194 119505 ________________ 194 119510 ________________ 194 119902 ________________ 194 119905 ________________ 194 119910 ________________ 194 120705 ________________ 196 120710 ________________ 196 120905 ________________ 196 120910 ________________ 196 120925 ________________ 196 121110 ________________ 196 121125 ________________ 196 121140 ________________ 196 121160000______________ 31 121160150______________ 31 121160151______________ 31 121160251______________ 31 121160900______________ 31 121160910______________ 31 121160920______________ 31 121180 ________________ 196 121310 ________________ 196 121320000______________ 31 121320250______________ 31 121325 ________________ 196 121350 ________________ 196 121510 ________________ 196 121525 ________________ 196
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
275
Index
121550 ________________ 196 121599 ________________ 196 121710 ________________ 196 121725 ________________ 196 121750 ________________ 196 121799 ________________ 196 121910 ________________ 196 121925 ________________ 196 121950 ________________ 196 121-710-1101/1 ________ 123 121A ___________________ 20 122010 ________________ 197 122050 ________________ 197 123705 ________________ 195 123710 ________________ 195 123905 ________________ 195 123910 ________________ 195 123A ___________________ 20 124001000_____________ 122 124102 ________________ 195 124110 ________________ 195 124125 ________________ 195 124140 ________________ 195 124180 ________________ 195 124310 ________________ 195 124325 ________________ 195 124350 ________________ 195 124502 ________________ 195 124510 ________________ 195 124525 ________________ 195 124550 ________________ 195 124599 ________________ 195 124710 ________________ 195 124725 ________________ 195 124750 ________________ 195 124799 ________________ 195 124910 ________________ 195 124925 ________________ 195 124950 ________________ 195 124999 ________________ 195 126310 ________________ 196 126325 ________________ 196
126350 ________________ 196 126510 ________________ 196 126525 ________________ 196 126550 ________________ 196 126599 ________________ 196 126710 ________________ 196 126725 ________________ 196 126750 ________________ 196 126799 ________________ 196 12BkT__________________ 35 12MP.oeM ______________ 35 12VAD _________________ 34 12VBP.oeM _____________ 36 12VBPS2.oeM __________ 36 12VBPS2 _______________ 36 12VBP__________________ 36 12VBR.oeM ____________ 36 12VBR.PG ______________ 36 12VBRAD.oeM __________ 36 12VBRAD _______________ 36 12VBRo ________________ 36 12VBRS2.oeM __________ 36 12VBRS2 _______________ 36 12VBR _________________ 36 12VCP6 ________________ 36 12VCPS2 _______________ 36 12VCP _________________ 36 12VPG.oeM ____________ 34 12VPG _____________ 34, 139 12VPk__________________ 34 12VPL.oeM _____________ 35 12VRC.oeM ____________ 34 12VRC.PG ______________ 34 12VRCo.PG ____________ 34 12VRCo ________________ 34 12VRCW.oeM ___________ 34 12VRCW________________ 34 12VRCy ________________ 34 12VRC _________________ 34 12VTR __________________ 35 12VXC _________________ 34 12VXT __________________ 34
130705 ________________ 196 130710 ________________ 196 130902 ________________ 196 130905 ________________ 196 130910 ________________ 196 131110 ________________ 196 131130 ________________ 196 131150 ________________ 196 131151 ________________ 197 131302 ________________ 196 131310 ________________ 196 131325 ________________ 196 131370 ________________ 196 131510 ________________ 196 131525 ________________ 196 131550 ________________ 196 131590 ________________ 196 131710 ________________ 196 131725 ________________ 196 131750 ________________ 196 131799 ________________ 196 131802000______________ 46 131804000______________ 46 133310 ________________ 196 133325 ________________ 196 133510 ________________ 196 133525 ________________ 196 133590 ________________ 196 133710 ________________ 196 133725 ________________ 196 140100250_____________ 228 140100360_____________ 228 140100500_____________ 228 140103000_____________ 231 140104000_____________ 231 140300350_____________ 228 140300500_____________ 228 140300750_____________ 228 140301000_____________ 228 140301600_____________ 228 140302000_____________ 228 140320350_____________ 231
140320500_____________ 231 140320750_____________ 231 140321000_____________ 231 140500500_____________ 230 140500750_____________ 230 140600200_____________ 229 140600250_____________ 229 140600420_____________ 229 140600650_____________ 229 140601050_____________ 229 140700200_____________ 229 140700250_____________ 229 140700420_____________ 229 140700650_____________ 229 140701050_____________ 229 141100650_____________ 229 141101000_____________ 229 141410 ________________ 197 141425 ________________ 197 141500010_____________ 227 141500030_____________ 227 141500220_____________ 227 142410 ________________ 199 142425 ________________ 199 142499 ________________ 199 142610 ________________ 199 142625 ________________ 199 142650 ________________ 199 142810 ________________ 199 150510 ________________ 199 150525 ________________ 199 150CC.oeM ____________ 60 150CCI _________________ 60 150CCTM.oeM__________ 60 151025 ________________ 199 151050 ________________ 199 151510 ________________ 199 151525 ________________ 199 151550 ________________ 199 151560 ________________ 199 151710 ________________ 199 151725 ________________ 199
276
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Index
151750 ________________ 199 1520BI.oeM ____________ 26 152Ay __________________ 21 153010 ________________ 197 153050 ________________ 197 153110 ________________ 198 153150 ________________ 198 153530 ________________ 199 153725 ________________ 199 153925 ________________ 199 153Ay __________________ 21 154010 ________________ 197 154030 ________________ 197 154510 ________________ 198 154525 ________________ 198 154Ay __________________ 21 155010 ________________ 198 155050 ________________ 198 156410 ________________ 198 156425 ________________ 198 156450 ________________ 198 156610 ________________ 198 156625 ________________ 198 157Ay __________________ 21 158010 ________________ 197 158025 ________________ 197 1591-fI.GRy.oeM _______ 26 1591-fI.WhT ____________ 26 1591-fI _________________ 26 15M32AXP ______________ 29 15M32AX _______________ 29 15MSPPXP______________ 28 15MSPPX _______________ 28 16001-RI _______________ 58 16003-RI _______________ 58 16061 __________________ 58 16102 __________________ 58 16153 __________________ 58 16202 __________________ 58 162Ay __________________ 21 165Ay __________________ 21 180003 ________________ 193
180503 ________________ 193 180703 ________________ 193 180803 ________________ 193 180903 ________________ 193 182103 ________________ 193 182303 ________________ 193 182503 ________________ 193 182803 ________________ 193 182903 ________________ 193 183003 ________________ 193 184003 ________________ 193 184103 ________________ 193 184150P-01-1 __________ 120 184303 ________________ 193 184503 ________________ 193 184703 ________________ 193 184803 ________________ 193 184903 ________________ 193 185003 ________________ 193 185050f/DSP __________ 120 185080f/DSP __________ 120 185100f-01-1 __________ 120 186003 ________________ 193 186803 ________________ 193 188003 ________________ 193 188803 ________________ 193 189130 ________________ 200 189131 ________________ 200 189134 ________________ 200 189135 ________________ 200 189136 ________________ 200 189137 ________________ 200 189140 ________________ 200 189141 ________________ 200 189144 ________________ 200 189145 ________________ 200 189146 ________________ 200 189147 ________________ 200 189303 ________________ 197 189800 ________________ 200 189849 ________________ 200 199109 _________________ 26
199109Pk ______________ 26 199110 _________________ 26 199110Pk ______________ 26 199114 _________________ 28 199115 _________________ 29 199116 _________________ 17 199117 _________________ 17 199119 _________________ 17 199120 _________________ 17 199128 _________________ 22 199136 _________________ 10 199200 ________________ 211 199201 ________________ 211 199202 ________________ 211 199203 ________________ 211 199204 ________________ 211 199205 ________________ 211 199206 ________________ 211 199207 ________________ 211 199208 ________________ 211 199209 ________________ 211 199210 ________________ 211 199211 ________________ 211 199212 ________________ 211 199213 ________________ 211 199214 ________________ 211 199215 ________________ 211 199216 ________________ 211 199217 ________________ 211 199218 ________________ 211 199219 ________________ 211 199220 ________________ 211 199221 ________________ 211 199222 ________________ 211 199223 ________________ 211 199224 ________________ 212 199225 ________________ 212 199226 ________________ 212 199227 ________________ 212 199228 ________________ 212 199229 ________________ 212 199230 ________________ 212
Index
199232 ________________ 213 199233 ________________ 213 199234 ________________ 213 199235 ________________ 213 199236 ________________ 213 199237 ________________ 212 199238 ________________ 212 199239 ________________ 212 199240 ________________ 212 199241 ________________ 212 199242 ________________ 212 199243 ________________ 212 199244 ________________ 212 199245 ________________ 212 199246 ________________ 211 199247 ________________ 211 199248 ________________ 211 199249 ________________ 211 199250 ________________ 212 199251 ________________ 212 199252 ________________ 212 199253 ________________ 212 199254 ________________ 211 199255 ________________ 212 199256 ________________ 211 199257 ________________ 212 199258 ________________ 212 199259 ________________ 211 199260 ________________ 211 199261 ________________ 212 199262 ________________ 213 199263 ________________ 213 1M32AXP _______________ 29 1MSPPXP _______________ 28 1MSPPX ________________ 28 1RPC50 ________________ 22 1RPC __________________ 22 200250 ________________ 206 200252 ________________ 206 200258 ________________ 206 200259 ________________ 206
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
277
Index
2018BP-12.oeM _________ 37 2018BP-12 ______________ 37 2018BP-24.oeM _________ 37 2018BP-24 ______________ 37 2018BR-MB _____________ 37 2018BR.oeM.BPS _______ 37 2018BR.oeM ___________ 37 2018BR ________________ 37 2018MB.oeM ___________ 37 2018MB ________________ 37 2018PkG _______________ 37 202175 ________________ 206 202176 ________________ 206 202319 ________________ 257 202320 ________________ 257 203100 ________________ 206 205CRCN_______________ 25 205CRPN _______________ 25 205CRR ________________ 25 20MSPPXP______________ 28 20MSPPX _______________ 28 2100-B ________________ 109 2100 __________________ 109 210100 ________________ 203 210110 ________________ 203 210120 ________________ 203 210130 ________________ 203 210140 ________________ 203 210161 ________________ 203 210162 ________________ 203 210163 ________________ 203 210164 ________________ 203 210165 ________________ 203 2101-B ________________ 109 2101 __________________ 109 210202 ________________ 201 210203 ________________ 201 210204 ________________ 201 210211 ________________ 201 210212 ________________ 201 210213 ________________ 201 210214 ________________ 201
210215 ________________ 201 210216 ________________ 201 210222 ________________ 201 210223 ________________ 201 210224 ________________ 201 210225 ________________ 201 210226 ________________ 201 210227 ________________ 201 210233 ________________ 201 210234 ________________ 201 210235 ________________ 201 210236 ________________ 201 2102-3-B ______________ 109 2102-B ________________ 109 2102 __________________ 109 210302 ________________ 202 210312 ________________ 202 210313 ________________ 202 210322 ________________ 202 210323 ________________ 202 210612 ________________ 203 210613 ________________ 203 210718 ________________ 203 210719 ________________ 203 210818 ________________ 202 210819 ________________ 202 210828 ________________ 202 210829 ________________ 202 2110A-B _______________ 109 2110A _________________ 109 2111A-B _______________ 109 2111A _________________ 109 2112A-B _______________ 109 2112A _________________ 109 211408 ________________ 202 211409 ________________ 202 211418 ________________ 202 211419 ________________ 202 211428 ________________ 202 211429 ________________ 202 211480 ________________ 205 211490 ________________ 205
21730100 _______________ 78 21730400 _______________ 46 220002 ________________ 217 220003 ________________ 217 220004 ________________ 217 220007 ________________ 217 220020 ________________ 217 220100 ________________ 203 220110 ________________ 203 22011A-P ______________ 261 22011MA-P ____________ 261 220120 ________________ 203 22012A-P ______________ 261 22012MA-P ____________ 261 22014-P ___________ 260, 261 220161 ________________ 203 220162 ________________ 203 220163 ________________ 203 220202 ________________ 201 220203 ________________ 201 220212 ________________ 201 220213 ________________ 201 220214 ________________ 201 220215 ________________ 201 220216 ________________ 201 220222 ________________ 201 220223 ________________ 201 220224 ________________ 201 220225 ________________ 201 220226 ________________ 201 220312 ________________ 202 220313 ________________ 202 220322 ________________ 202 220323 ________________ 202 22040A ____________ 260, 261 22041A ____________ 260, 261 22044 _____________ 260, 261 22045 _________________ 261 220612 ________________ 203 220615 ________________ 203 220719 ________________ 203 220818 ________________ 202
220819 ________________ 202 220828 ________________ 202 221408 ________________ 202 221409 ________________ 202 221418 ________________ 202 221419 ________________ 202 221428 ________________ 202 221429 ________________ 202 22200 _________________ 261 22201 _________________ 261 22208-24 ______________ 261 22208A ________________ 261 22209 _________________ 261 222110 ________________ 203 222162 ________________ 203 22218A ________________ 261 22219A ________________ 261 222213 ________________ 201 22224 _________________ 254 22230-P _______________ 261 22240 _________________ 261 2300A-B _______________ 109 2300A _________________ 109 230100 ________________ 203 230110 ________________ 203 230120 ________________ 203 230130 ________________ 203 230140 ________________ 203 230150 ________________ 203 230164 ________________ 203 230165 ________________ 203 230201 ________________ 201 230202 ________________ 201 230203 ________________ 201 230205 ________________ 201 230206 ________________ 201 230211 ________________ 201 230212 ________________ 201 230213 ________________ 201 230214 ________________ 201 230215 ________________ 201 230216 ________________ 201
278
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Index
230221 ________________ 201 230222 ________________ 201 230223 ________________ 201 230224 ________________ 201 230225 ________________ 201 230226 ________________ 201 230227 ________________ 201 230233 ________________ 201 230234 ________________ 201 230235 ________________ 201 230236 ________________ 201 230237 ________________ 201 230243 ________________ 201 230244 ________________ 201 230245 ________________ 201 230246 ________________ 201 230254 ________________ 201 230255 ________________ 201 230257 ________________ 201 230301 ________________ 202 230302 ________________ 202 230303 ________________ 202 230311 ________________ 202 230312 ________________ 202 230313 ________________ 202 230322 ________________ 202 230323 ________________ 202 2303A-B _______________ 109 2303A _________________ 109 2304A-B _______________ 109 2304A _________________ 109 230510 ________________ 203 230520 ________________ 203 230612 ________________ 203 230615 ________________ 203 230708 ________________ 203 230709 ________________ 203 230718 ________________ 203 230719 ________________ 203 230818 ________________ 202 230819 ________________ 202 230828 ________________ 202
230829 ________________ 202 231408 ________________ 202 231409 ________________ 202 231418 ________________ 202 231419 ________________ 202 231428 ________________ 202 231429 ________________ 202 24010800 _______________ 66 24011200 _______________ 66 24012000 _______________ 66 24020800 _______________ 66 24021500 _______________ 66 24022500 _______________ 66 24026000 _______________ 66 24027000 _______________ 66 24095100 _______________ 66 242233 ________________ 207 242234 ________________ 207 242235 ________________ 207 242236 ________________ 207 242237 ________________ 207 242243 ________________ 207 242244 ________________ 207 242245 ________________ 207 242246 ________________ 207 242253 ________________ 207 242254 ________________ 207 242255 ________________ 207 242256 ________________ 207 242257 ________________ 207 242264 ________________ 207 242265 ________________ 207 242266 ________________ 207 242275 ________________ 207 242276 ________________ 207 242284 ________________ 207 242285 ________________ 207 242286 ________________ 207 242294 ________________ 207 242295 ________________ 207 242296 ________________ 207 242297 ________________ 207
242715 ________________ 207 242716 ________________ 207 242725 ________________ 207 242726 ________________ 207 242727 ________________ 207 244233 ________________ 207 244234 ________________ 207 244235 ________________ 207 244236 ________________ 207 244245 ________________ 207 244246 ________________ 207 244254 ________________ 207 244255 ________________ 207 244256 ________________ 207 244265 ________________ 207 244266 ________________ 207 244285 ________________ 207 244286 ________________ 207 244295 ________________ 207 244296 ________________ 207 244725 ________________ 207 244726 ________________ 207 249003 ________________ 206 249007 ________________ 206 250001 ________________ 216 25012000 _______________ 66 2501 __________________ 113 25022500 _______________ 66 2502 __________________ 113 2504 __________________ 113 2505 __________________ 113 252130 ________________ 207 252140 ________________ 207 252150 ________________ 207 252160 ________________ 207 252170 ________________ 207 252180 ________________ 207 252190 ________________ 207 252233 ________________ 207 252234 ________________ 207 252235 ________________ 207 252236 ________________ 207
Index
252241 ________________ 207 252243 ________________ 207 252244 ________________ 207 252245 ________________ 207 252246 ________________ 207 252251 ________________ 207 252253 ________________ 207 252254 ________________ 207 252255 ________________ 207 252256 ________________ 207 252257 ________________ 207 252261 ________________ 207 252264 ________________ 207 252265 ________________ 207 252266 ________________ 207 252267 ________________ 207 252274 ________________ 207 252275 ________________ 207 252276 ________________ 207 252277 ________________ 207 252284 ________________ 207 252285 ________________ 207 252286 ________________ 207 252287 ________________ 207 252295 ________________ 207 252296 ________________ 207 252297 ________________ 207 252716 ________________ 207 252717 ________________ 207 252725 ________________ 207 252726 ________________ 207 252727 ________________ 207 2530 __________________ 113 2532 __________________ 113 255001 ________________ 216 25MSPPXP______________ 28 25MSPPX _______________ 28 25SPP.oeM _____________ 17 25SPPW.oeM ___________ 17 25SPPX ________________ 28 260010 ________________ 208
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
279
Index
260012 ________________ 208 260100 ________________ 208 260200 ________________ 208 2602A-12 _______________ 61 2602A-24-B _____________ 61 2602 ___________________ 61 260322 ________________ 208 260325 ________________ 208 260350 ________________ 208 260381 ________________ 208 2603 ___________________ 61 260505 ________________ 208 2606A-B ________________ 61 2606A __________________ 61 2607A-B ________________ 59 2607A __________________ 59 2608A-B ________________ 59 2608A __________________ 59 2610A-B ________________ 59 2610A __________________ 59 2611A-1-B ______________ 59 2611A-B ________________ 59 2611A __________________ 59 2612A __________________ 61 2613A __________________ 59 2614A __________________ 60 2620A __________________ 59 2621A __________________ 60 2622A-230 ______________ 60 2622A __________________ 60 2623A __________________ 59 2631A __________________ 59 2632A-230 ______________ 60 2632A __________________ 60 2633A __________________ 60 2635-B _________________ 59 27510700 _______________ 64 27520700 _______________ 64 28010300 _______________ 64 28010500 _______________ 64 28020300 _______________ 64 28020500 _______________ 64
300000 ________________ 205 30000 _________________ 240 30002 _________________ 240 30004 _________________ 241 30005 _________________ 241 300259 _________________ 35 300275 _________________ 35 301103 ________________ 209 301106 ________________ 209 301124 ________________ 209 301148 ________________ 209 301503 ________________ 209 301506 ________________ 209 301BkRIGN.oeM ________ 14 301BkRPL.oeM _________ 14 301CRMB ______________ 27 301eL-B.fR _____________ 10 301eL-B.GRAy __________ 10 301eL-B.oeM ___________ 10 301eL-B.W/L ____________ 10 301eL-BXPk ____________ 28 301eL-BX _______________ 28 301eL-B ________________ 10 301eLCB _______________ 10 301RCD.oeM ___________ 14 301RCDkITIGN.oeM ____ 14 301RCDPL.oeM _________ 14 302103 ________________ 209 302106 ________________ 209 302124 ________________ 209 302148 ________________ 209 303103 ________________ 209 303106 ________________ 209 303124 ________________ 209 303148 ________________ 209 303303 ________________ 209 303602 ________________ 209 303648 ________________ 209 303948 ________________ 209 303SSBkRIGN.oeM _____ 14 303SSBkRPL.oeM ______ 14 303SSeL-B.oeM ________ 10
303SSeL-BXPk __________ 28 303SSeL-BX ____________ 28 303SSeL-B _____________ 10 303SSo ________________ 10 303SSRCD.oeM_________ 14 303SSRCDkITIGN.oeM __ 14 303SSRCDPL.oeM ______ 14 304103 ________________ 209 304106 ________________ 209 304124 ________________ 209 304148 ________________ 209 304303 ________________ 209 304403 ________________ 209 304424 ________________ 209 304503 ________________ 209 304506 ________________ 209 304602 ________________ 209 304603 ________________ 209 304606 ________________ 209 304624 ________________ 209 304648 ________________ 209 304BkRIGN.oeM ________ 14 304BkRPL.oeM _________ 14 304eL-B.NT _____________ 10 304eL-B.oeM ___________ 10 304eL-BCR.oeM ________ 10 304eL-BCR _____________ 10 304eL-BX.NT____________ 28 304eL-B ________________ 10 304eLCB _______________ 10 304RCD.oeM ___________ 14 304RCDkITIGN.oeM ____ 14 304RCDPL.oeM _________ 14 3050BI _________________ 10 305103 ________________ 209 305106 ________________ 209 305124 ________________ 209 305148 ________________ 209 305603 ________________ 209 305624 ________________ 209 305648 ________________ 209 305BC _________________ 37
305BP.oeM _____________ 37 305BP __________________ 37 305CRCN.oeM__________ 23 305CRCN.VPk __________ 23 305CRCN_______________ 23 305CRCXNPk ___________ 28 305CRCXN _____________ 28 305CRMB ______________ 27 305CRPN.oeM __________ 23 305CRPN.VPk __________ 23 305CRPN _______________ 23 305CRRB.oeM _______ 23, 37 305CRRB ____________ 23, 37 305CRR ________________ 23 306103 ________________ 209 306106 ________________ 209 306124 ________________ 209 306148 ________________ 209 306503 ________________ 209 306506 ________________ 209 306524 ________________ 209 306602 ________________ 209 306603 ________________ 209 306606 ________________ 209 306624 ________________ 209 306648 ________________ 209 306948 ________________ 209 307103 ________________ 209 307124 ________________ 209 307148 ________________ 209 307648 ________________ 209 307948 ________________ 209 309002 ________________ 205 309003 ________________ 205 309025 ________________ 205 309099 ________________ 205 309102 ________________ 205 309103 ________________ 205 309125 ________________ 205 309199 ________________ 205 309202 ________________ 205 309203 ________________ 205
280
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Index
309225 ________________ 205 309299 ________________ 205 31012B ________________ 247 31014B ________________ 247 31016B ____________ 245, 247 31018B ________________ 247 310203 ________________ 204 31020B ________________ 247 310225 ________________ 204 31022B ________________ 247 31024B ________________ 247 310299 ________________ 204 310303 ________________ 204 310325 ________________ 204 310399 ________________ 204 31112B ____________ 245, 247 31114B ____________ 245, 247 31116B ________________ 247 31118B ____________ 245, 247 311203 ________________ 204 31120B ____________ 245, 247 311225 ________________ 204 31122B ____________ 245, 247 31124B ____________ 245, 247 311299 ________________ 204 311303 ________________ 204 311325 ________________ 204 311399 ________________ 204 311403 ________________ 204 311425 ________________ 204 311499 ________________ 204 311503 ________________ 204 311525 ________________ 204 311599 ________________ 204 311603 ________________ 204 311625 ________________ 204 311699 ________________ 204 312203 ________________ 204 312225 ________________ 204 312299 ________________ 204 312303 ________________ 204 312325 ________________ 204
312399 ________________ 204 312403 ________________ 204 312425 ________________ 204 312499 ________________ 204 312503 ________________ 204 312525 ________________ 204 312599 ________________ 204 312603 ________________ 204 312625 ________________ 204 312699 ________________ 204 314225 ________________ 204 314299 ________________ 204 314325 ________________ 204 314399 ________________ 204 315225 ________________ 204 315299 ________________ 204 315325 ________________ 204 316803 ________________ 205 316825 ________________ 205 316899 ________________ 205 316925 ________________ 205 317803 ________________ 205 317825 ________________ 205 317899 ________________ 205 317903 ________________ 205 317925 ________________ 205 317999 ________________ 205 318825 ________________ 205 318925 ________________ 205 319825 ________________ 205 319899 ________________ 205 319925 ________________ 205 319999 ________________ 205 320001 ________________ 216 32000 _________________ 240 32001 _________________ 240 32002 _________________ 240 326103 ________________ 210 326124 ________________ 210 326148 ________________ 210 326202 ________________ 210 326603 ________________ 210
326624 ________________ 210 326648 ________________ 210 327124 ________________ 210 327202 ________________ 210 327606 ________________ 210 327624 ________________ 210 33004 _________________ 246 33005 _________________ 246 33006A ____________ 242, 244 33007A ____________ 242, 244 33010A ____________ 242, 244 33012A ____________ 242, 244 33014A ____________ 242, 244 33015 _________________ 246 33016 _________________ 246 33017 _________________ 246 33021B ________________ 246 33021S ________________ 246 33022B ________________ 246 33022S ________________ 246 33022 _________________ 246 33023 _________________ 246 33024B ________________ 246 33024S ________________ 246 33024 _________________ 246 33025 _________________ 239 33026B ____________ 245, 246 33026S ____________ 245, 246 33028B ____________ 245, 246 33028S ____________ 245, 246 33030B ____________ 245, 246 33030S ____________ 245, 246 33032A ____________ 242, 244 33037A ____________ 242, 244 33070A ____________ 242, 244 33082 _____________ 242, 243 33084W ___________ 242, 244 33084 _____________ 242, 243 33086W ___________ 242, 244 33086 _____________ 242, 243 33088W ___________ 242, 244 33088 _________________ 242
Index
33090 _____________ 242, 243 33092W ___________ 242, 244 33092 _____________ 242, 243 33094W _______________ 242 33094 _____________ 242, 243 33096W ___________ 242, 243 33096 _________________ 242 33104 _____________ 245, 246 33105 _____________ 245, 246 33106A ________________ 244 33107A ________________ 244 33110A ________________ 244 33112A ________________ 244 33114A ________________ 244 33115 _____________ 245, 246 33116 _____________ 245, 246 33117 _____________ 245, 246 33121B ____________ 245, 246 33121S ____________ 245, 246 33122B ____________ 245, 246 33122S ____________ 245, 246 33124B ________________ 246 33124S ____________ 245, 246 33125 _________________ 239 33126B ____________ 245, 246 33126S ____________ 245, 246 33130S ____________ 245, 246 33132A ________________ 244 33137A ________________ 244 33170A ________________ 244 33182 _________________ 243 33184W _______________ 244 33184 _________________ 243 33186W _______________ 244 33186 _________________ 243 33188W _______________ 243 33188 _________________ 242 33190W _______________ 244 33190 _________________ 243 33192W _______________ 244 33192 _________________ 243
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
281
Index
33194W _______________ 244 33194 _________________ 243 33196W _______________ 243 33196 _________________ 242 33505 _________________ 247 33513 _________________ 247 33514 _________________ 247 33515 _________________ 247 34000 _________________ 239 34001 _________________ 239 34005 _________________ 239 34010 _________________ 239 34011 _________________ 239 34015 _________________ 239 34210 _________________ 239 35010 _________________ 240 35040 _________________ 240 35050 _________________ 240 35SPP.oeM _____________ 17 36011205 _______________ 73 36012005 _______________ 73 36012505 _______________ 73 36014005 _______________ 73 36021205 _______________ 73 36022005 _______________ 73 36022505 _______________ 73 36024005 _______________ 73 36042505 _______________ 73 36045005 _______________ 73 36110 _________________ 238 36111 _________________ 238 36161 _________________ 238 36180 _________________ 238 36181 _________________ 238 37012505 _______________ 70 37014005 _______________ 70 37022505 _______________ 70 37024005 _______________ 70 37100 _________________ 238 37110 _________________ 238 37111 _________________ 238 37161 _________________ 238
37180 _________________ 238 37181 _________________ 238 37200 _________________ 238 38000 _________________ 239 38001 _________________ 239 38005 _________________ 239 38010 _________________ 239 38011 _________________ 239 400000 ________________ 213 40010606 _______________ 57 40010806 _______________ 57 40020156 _______________ 57 40020256 _______________ 57 40020506 _______________ 57 40020756 _______________ 57 40021006 _______________ 57 40031006 _______________ 57 40040256 _______________ 57 40040506 _______________ 57 4006 __________________ 114 4008 __________________ 114 401122 ________________ 213 401182 ________________ 213 401251 ________________ 213 401252 ________________ 213 401255 ________________ 213 4012 __________________ 114 401312 ________________ 213 401372 ________________ 213 401375 ________________ 213 401432 ________________ 213 401502 ________________ 213 401622 ________________ 213 401752 ________________ 213 401892 ________________ 213 4018 __________________ 114 401912 ________________ 213 401932 ________________ 213 402252 ________________ 213 402312 ________________ 213 402372 ________________ 213 402502 ________________ 213
402622 ________________ 213 402752 ________________ 213 402892 ________________ 213 403182 ________________ 213 403252 ________________ 213 403312 ________________ 213 403372 ________________ 213 403432 ________________ 213 403502 ________________ 213 403562 ________________ 213 403622 ________________ 213 403752 ________________ 213 403872 ________________ 213 403892 ________________ 213 403902 ________________ 213 404152 ________________ 213 404172 ________________ 213 404202 ________________ 213 404252 ________________ 213 404302 ________________ 213 43011000 _______________ 52 43011500 _______________ 52 43020600 _______________ 55 44010250 _______________ 52 44010350 _______________ 52 44010500 _______________ 52 44010700 _______________ 52 44011000 _______________ 52 44020120 _______________ 55 44020200 _______________ 55 44020300 _______________ 55 44020400 _______________ 55 44020600 _______________ 55 44020800 _______________ 55 44021000 _______________ 55 452251 ________________ 215 452255 ________________ 215 452381 ________________ 215 452385 ________________ 215 452501 ________________ 215 452505 ________________ 215 452751 ________________ 215
452755 ________________ 215 452900 ________________ 215 452905 ________________ 215 4531001 _______________ 114 4531011 _______________ 114 453382 ________________ 215 453386 ________________ 215 453502 ________________ 215 453752 ________________ 215 453756 ________________ 215 453901 ________________ 215 45511000 _______________ 45 45511200 _______________ 45 45511400 _______________ 45 45511600 _______________ 45 46020950 _______________ 45 4700CR ________________ 25 4721CR ________________ 25 4731CR ________________ 25 48012090 _______________ 45 48012130 _______________ 45 48024075 _______________ 45 48024110 _______________ 45 48024150 _______________ 45 500, 500A _____________ 261 500A __________________ 258 500eL __________________ 24 500R ___________________ 24 501, 501A _____________ 261 501A __________________ 258 502-1 _____________ 258, 261 502-2 _____________ 258, 261 502, 502A _____________ 261 502A __________________ 258 503-1 _____________ 259, 261 503-2 _____________ 259, 261 503, 503A _____________ 261 503A __________________ 259 505 ___________________ 259 50SPP.oeM _____________ 17 50SPPW.oeM ___________ 17 50SPPX ________________ 28
282
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Index
50SPP __________________ 17 510R ___________________ 24 511016 ____________ 265, 267 520053 ____________ 263, 267 520057 ____________ 263, 267 520067 ____________ 264, 267 520068 ____________ 263, 267 520082 ____________ 263, 267 520090 ____________ 263, 267 520093 ____________ 264, 267 520094 ____________ 263, 267 520097 ____________ 264, 267 520168 ____________ 263, 267 520194 ____________ 263, 267 520906 ____________ 263, 267 520912 ____________ 263, 267 521003 ____________ 263, 267 521004 ____________ 263, 267 521034 ____________ 264, 267 521076 ____________ 263, 267 521126 ____________ 263, 267 521128 ____________ 263, 267 521140 ____________ 263, 267 521141 ____________ 264, 267 521142 ____________ 263, 267 521156 ____________ 264, 267 521157 ____________ 264, 267 521158 ____________ 264, 267 521159 ____________ 263, 267 521162 ____________ 264, 267 521164 ____________ 264, 267 521166 ____________ 265, 267 521176 ____________ 263, 267 521204 ____________ 263, 267 521224 ____________ 263, 267 521228 ____________ 263, 267 521383 ____________ 264, 267 521416 ____________ 263, 267 521816 ____________ 263, 267 522112 ____________ 264, 267 522122 ____________ 264, 267 522124 ____________ 264, 267
522126 ____________ 264, 267 522127 ____________ 264, 267 522129 ____________ 264, 267 522131 ____________ 264, 267 5262CRR.GRy __________ 25 5262CRR _______________ 25 5266CR ________________ 25 5269CR ________________ 25 529095 ____________ 264, 267 529102 ____________ 264, 267 529104 ____________ 264, 267 529168 ____________ 266, 267 529200 ____________ 264, 267 529300 ____________ 265, 267 529333 ____________ 264, 267 529337 ____________ 266, 267 529338 ____________ 266, 267 529340 ____________ 265, 267 529341 ____________ 265, 267 529344 ____________ 265, 267 529355 ____________ 266, 267 529361 ____________ 266, 267 529362 ____________ 266, 267 529367 ____________ 266, 267 529368 ____________ 266, 267 529370 ____________ 266, 267 529371 ____________ 266, 267 529381 ____________ 266, 267 529385 ____________ 266, 267 529386 ____________ 266, 267 529405 ____________ 265, 267 529406 ____________ 265, 267 529407 ____________ 265, 267 529410 ____________ 262, 267 529411 ____________ 262, 267 529412 ____________ 262, 267 529413 ____________ 262, 267 529414 ____________ 262, 267 529416 ____________ 262, 267 529417 ____________ 262, 267 529419 ____________ 262, 267 529420 ____________ 262, 267
529421 ____________ 262, 267 529422 ____________ 262, 267 529423 ____________ 262, 267 529424 ____________ 262, 267 531015 ____________ 265, 267 531025 ____________ 265, 267 531050 ____________ 265, 267 531075 ____________ 265, 267 531100 ____________ 265, 267 532025 ____________ 265, 267 533015 ____________ 265, 267 533025 ____________ 265, 267 533050 ____________ 265, 267 533075 ____________ 265, 267 5366CR ________________ 25 5369CR.oeM ___________ 25 55003300 _______________ 83 55003400 _______________ 83 55003500 ______________ 152 55006010 ______________ 152 55006015 ______________ 152 55006060 ______________ 152 55008005 ______________ 152 55008105 ______________ 152 55008205 ______________ 152 55010600 _______________ 83 55010900 _______________ 83 55011300 _______________ 83 55106000 ______________ 152 55106100* _____________ 152 551505 ________________ 121 551510 ________________ 121 551515 ________________ 121 551520 ________________ 121 551525 ________________ 121 551530 ________________ 121 551540 ________________ 121 551550 ________________ 121 551605 ________________ 121 551610 ________________ 121 551615 ________________ 121 551620 ________________ 121
Index
551630 ________________ 121 551640 ________________ 121 551650 ________________ 121 551705 ________________ 121 551710 ________________ 121 551715 ________________ 121 551720 ________________ 121 551725 ________________ 121 551730 ________________ 121 551740 ________________ 121 551750 ________________ 121 552820 ________________ 122 552830 ________________ 122 552850 ________________ 122 553002 ________________ 123 553004 ________________ 123 553005 ________________ 123 553008 ________________ 123 553020 ________________ 123 553021 ________________ 123 553022 ________________ 123 553041 ________________ 123 553091 ________________ 202 553093 ________________ 202 553095 ________________ 202 554000 ________________ 123 554001 ________________ 123 554010 ________________ 143 554011 ________________ 143 554012 ________________ 143 554016 ________________ 143 554022 ________________ 143 554024 ________________ 143 554026 ________________ 143 554027 ________________ 143 554028 ________________ 143 554029 ________________ 143 554030 ________________ 143 554032 ________________ 143 554033 ________________ 143 554035 ________________ 143
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
283
Index
554036 ________________ 143 554038 ________________ 143 555010 ________________ 144 555022 ________________ 144 555025 ________________ 144 555026 ________________ 144 555028 ________________ 144 555033 ________________ 144 555105 ________________ 144 556010 ________________ 144 556022 ________________ 144 556028 ________________ 144 5739CR ________________ 25 600-DCM-10M _________ 181 600-DCM-5M___________ 181 600-GDL ______________ 185 600-GDRV _____________ 185 600-GD________________ 185 600-LPG _______________ 185 600-TGSk _____________ 183 600-TLM-SIf ___________ 183 601005 ________________ 115 601010 ________________ 115 601015 ________________ 115 601020 ________________ 115 601025 ________________ 115 601030 ________________ 115 601040 ________________ 115 601050 ________________ 115 601070 ________________ 115 601075 ________________ 115 601080 ________________ 115 601100 ________________ 115 601110 ________________ 115 601114 ________________ 115 601150 ________________ 115 601200 ________________ 115 601250 ________________ 115 601300 ________________ 115 6017y __________________ 26 6018y __________________ 26 602030 ________________ 115
602050 ________________ 115 602062 ________________ 115 602075 ________________ 115 602100 ________________ 115 602150 ________________ 115 602200 ________________ 115 602250 ________________ 115 602300 ________________ 115 603905 ________________ 115 603910 ________________ 115 603915 ________________ 115 603920 ________________ 115 603930 ________________ 115 604003 ________________ 115 604005 ________________ 115 604007 ________________ 115 604010 ________________ 115 604015 ________________ 115 604020 ________________ 115 604025 ________________ 115 604030 ________________ 115 604200 ________________ 115 604300 ________________ 115 605010 ________________ 115 605020 ________________ 115 605030 ________________ 115 605050 ________________ 115 605070 ________________ 115 605100 ________________ 115 605150 ________________ 115 607006 ________________ 118 607010 ________________ 118 607011 ________________ 118 607012 ________________ 118 607013 ________________ 118 607014 ________________ 118 607015 ________________ 118 607016 ________________ 118 607017 ________________ 118 607019 ________________ 118 607020 ________________ 118 607021 ________________ 118
607022 ________________ 118 607023 ________________ 118 607122 ________________ 117 607123 ________________ 117 6079 ___________________ 27 608001 ________________ 216 6080 ___________________ 27 6083CR ________________ 27 6084CR ________________ 27 61002600 _______________ 88 61003400 _______________ 88 61004000 _______________ 88 6152SPP-12SC __________ 17 6152SPP-25_____________ 17 6152SPPW-25 ___________ 17 6152SPPW-55.P/o _______ 17 6152SPPW-75.P/o _______ 17 6152SPPW ______________ 17 6152SPP _______________ 17 6153SPP-25_____________ 17 6153SPPW ______________ 17 6153SPPX ______________ 29 6153SPP _______________ 17 62000550 _______________ 88 62000700 _______________ 88 62000900 _______________ 88 62001300 _______________ 88 62001600 _______________ 88 62002250 _______________ 88 62002700 _______________ 88 63001150 _______________ 88 63001500 _______________ 88 63001851 _______________ 88 6343eL-BX______________ 29 6343eL-B _______________ 11 6344BkRIGN.oeM_______ 14 6344eL-B.NT ____________ 12 6344eL-B.oeM __________ 12 6344eL-BCR.oeM _______ 12 6344eL-BCR ____________ 12 6344eL-B _______________ 12 6344RCD.oeM __________ 14
6344RCDkITIGN.oeM ___ 14 6351eL-BX______________ 29 6351eL-B _______________ 11 6351eL _________________ 11 6353BkRIGN.oeM_______ 14 6353eL-B.BLACk.oeM ___ 12 6353eL-B.GRAy _________ 12 6353eL-B.oeM __________ 12 6353eL-B _______________ 12 6353eLCB ______________ 12 6353eL _________________ 12 6353RCD.oeM __________ 14 6353RCDkITIGN.oeM ___ 14 6360CRN.oeM __________ 24 6360CRNXPk ___________ 29 6360CRNX ______________ 29 6360CRN _______________ 24 6361CRN _______________ 24 6364CRN.oeM __________ 24 6364CRN _______________ 24 6365CRN.oeM __________ 24 6365CRN _______________ 24 6369CR.oeM ___________ 24 6369CR ________________ 24 6370CR ________________ 24 6371eL-B.oeM __________ 11 6371eL-BX.uk __________ 29 6371eL-B _______________ 11 6371eLX________________ 29 6371eL _________________ 11 6373BkRIGN.oeM_______ 14 6373eL-B.oeM __________ 12 6373eL-B _______________ 12 6373eL.oeM ____________ 12 6373eLMB ______________ 27 6373eL _________________ 12 6373RCD.oeM __________ 14 6373RCDkITIGN.oeM ___ 14 6387000600 ___________ 122 6387001000 ___________ 122 6387001600 ___________ 122 6387002000 ___________ 122
284
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Index
6387002500 ___________ 122 6387003200 ___________ 122 64000250 _______________ 89 64000550 _______________ 89 64000850 _______________ 89 64001200 _______________ 89 64001400 _______________ 89 64002000 _______________ 89 6401CRCX ______________ 30 6401CRPX ______________ 30 6401eL-BX______________ 30 6402CRCX ______________ 30 6402CRPX ______________ 30 6402eL-BX______________ 30 66010320 _______________ 91 66020160 _______________ 91 68000280 _______________ 90 68000420 _______________ 90 68000500 _______________ 90 68000580 _______________ 90 68000750 _______________ 90 68001000 _______________ 90 68001250 _______________ 90 68001500 _______________ 90 68001650 _______________ 90 68002200 _______________ 90 68002700 _______________ 90 68060100 ______________ 208 68060200 ______________ 208 68060300 ______________ 208 68060400 ______________ 208 68060500 ______________ 208 68060600 ______________ 208 68060700 ______________ 208 68060800 ______________ 208 68060900 ______________ 208 68061000 ______________ 208 68451902 ______________ 208 68451914 ______________ 208 68453014 ______________ 208 68454002 ______________ 208 68456902 ______________ 208
68456914 ______________ 208 68457302 ______________ 208 68457314 ______________ 208 700115 ________________ 222 700B ___________________ 95 700 _________________ 94, 95 701007 ________________ 222 701009 ________________ 222 701010 ________________ 222 701030 ________________ 223 701-key-eP _____________ 95 701-key ________________ 95 701-MDVS-24V __________ 97 701-MDVS ______________ 97 701-MD ________________ 96 701-PM _________________ 94 701B ___________________ 95 701S-B _________________ 95 701S-PM _______________ 94 701S ________________ 94, 95 701 _____________ 94, 95,112 702015 ________________ 223 702024 ____________ 210, 223 702027 ____________ 210, 223 702030 ________________ 221 702033 ________________ 223 702040 ________________ 222 702064 ________________ 223 702065 ____________ 194, 221 702-2S/B ______________ 148 702-2S ________________ 148 702-2S ________________ 148 702-8-10-B_____________ 148 702-8-10_______________ 148 702-8-B _______________ 148 702-8 _________________ 148 702-Mfh-B ____________ 116 702-Mfh ______________ 116 702B _________________ 148 702SB _________________ 148 702 ___________________ 148 703-300A/B ____________ 146
703-300A ______________ 146 703-500A/B ____________ 146 703-500A ______________ 146 70403105 _____ 57, 66, 70, 73 70403163 ______________ 183 70404110 _______________ 66 70405000 ____________ 70, 73 70405010 _______________ 73 70405050 _______________ 70 704-4S/B ______________ 148 704-4S ________________ 148 704-4S ________________ 148 704-ANLB _____________ 148 704-ANL _______________ 118 704-ANL ______________ 148 705-100A ______________ 149 705-135A/B ____________ 149 705-135A ______________ 149 705-150A ______________ 149 705-50A/B _____________ 149 705-50A _______________ 149 705-80A/B _____________ 149 705-80A _______________ 149 705 ___________________ 149 706-2W ________________ 149 706-4WB ______________ 149 706-4W ________________ 149 707 ___________________ 149 708-102 _______________ 148 708-107 _______________ 108 708-42.5 ___________ 108, 148 708-54.5 _______________ 148 708-62.0 _______________ 148 708-64.5 _______________ 148 708-68.5 _______________ 148 708-70.0 _______________ 108 709-150/BD ____________ 108 709-150/DD ____________ 108 709-250/BD ____________ 108 709-250/DD ____________ 108 709-300/BD ____________ 108 709-300/DD ____________ 108
Index
71012 _________________ 237 71081 _________________ 237 71082 _________________ 237 710-140A-B _____________ 98 710-140A _______________ 98 71111M _______________ 237 71112 _________________ 237 71113 _________________ 237 71181 _________________ 237 71182 _________________ 237 711L __________________ 146 71212 _________________ 237 71312 _________________ 237 713-BT ________________ 136 713-eP ________________ 136 713-hB ________________ 136 713-MS ________________ 136 713-PS ________________ 136 713-SB ________________ 136 713-SS ________________ 136 713 _______________ 112, 136 714-140A-DVSR-B ______ 100 714-140A-DVSR ____ 100, 101 715-h _________________ 101 715-S _____________ 101, 102 715-V _____________ 100, 101 716-h-140A-DVSR ______ 101 716-SQ-140A-DVSR_____ 101 717-140A-DVSR ____ 101, 102 718-140A-DVSR ____ 101, 102 719-140A-DVSR ____ 101, 102 720-DP/B _______________ 95 720-DP _________________ 95 720-MDo-eP ____________ 97 720-MDo _______________ 96 720-MDVSo-24V ________ 97 720-MDVSo ____________ 97 720B ___________________ 95 720 ____________________ 95 721B ___________________ 95 721 ____________________ 95
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
285
Index
729488 ________________ 261 729489 ________________ 261 729491 ________________ 261 729492 ________________ 261 729493 ____________ 258, 261 729494 ____________ 259, 261 729528 ________________ 261 729823-P ______________ 261 729825 ________________ 261 729827-P ______________ 261 729828-P ______________ 261 729829-P ______________ 261 729830-P ______________ 261 730192 ________________ 259 73112 _________________ 235 73113 _________________ 235 73312 _________________ 235 73313 _________________ 235 7420CR.oeM ___________ 27 7420CR ________________ 27 750000 ________________ 215 75SPP.oeM _____________ 17 76030 _________________ 247 760375 ________________ 215 760500 ________________ 215 76130 _________________ 247 764998 ________________ 214 765000 ________________ 214 765002 ________________ 214 765004 ________________ 214 765006 ________________ 214 77010030 ______________ 157 77010050 ____ 52, 55, 57, 157 77010305 ___________ 42, 52, ___ 55, 57, 70, 73, 78, 82, 157 77010400 ___________ 42, 156 77020100 ___________ 42, 52, _________________55, 57, 158 77020200 ______________ 158 77020400 ______________ 159 77030100 ___________ 52, 55, _______________ 57, 160, 162 77030300 __________ 161, 162
77030450 ______ 78, 160, 162 77030475 ___ 70, 73, 160, 162 77030500 ___________ 52, 53, _______________ 55, 161, 162 77030700 ______ 66, 160, 162 77030800 __________ 160, 162 77030900 __________ 160, 162 77031000 __________ 160, 162 77031100 __________ 160, 162 77031200 ___________ 66, 162 77031300 __________ 160, 162 77031400 __________ 160, 162 77031500 __________ 160, 162 77031700 __________ 160, 162 77031800 __________ 160, 162 77031900 __________ 156, 162 77040000 ______________ 163 77040010 ______________ 163 77040015 ______________ 163 77040020 ______________ 163 77040050 ______________ 163 77040100 ______________ 163 77040300 ______________ 163 77040600 ______________ 163 77041000 ______________ 163 77041500 ______________ 163 77042000 ______________ 163 77042500 ______________ 163 77045000 ______________ 163 77049000 __________ 116, 163 77049040 __________ 116, 163 77049050 __________ 116, 163 77049060 __________ 116, 163 77049080 __________ 116, 163 77049100 __________ 116, 163 77049125 __________ 116, 163 77049160 __________ 116, 163 77049175 __________ 116, 163 77049200 __________ 116, 163 77049250 __________ 116, 163 77049300 __________ 116, 163 77049400 __________ 116, 163 77050000 ______________ 163
7715CRN.oeM __________ 24 7715CRNXPk ________ 29, 30 7715CRNX ___________ 29, 30 7715CRN _______________ 24 7715eLN.oeM __________ 24 7715eLN _______________ 24 7717N.oeM _____________ 24 7717N __________________ 24 7788CR ________________ 27 7879CR-fI.oeM _________ 27 7879CR-fI ______________ 27 7879CR ________________ 27 800-MS1_______________ 112 800-MS2_______________ 112 800-MS3_______________ 112 800-MS4_______________ 112 80-600-0021-00 ________ 181 80-600-0022-00 ________ 181 80-600-0023-00 ________ 182 80-600-0027-00 ________ 187 80-600-0028-00 ________ 187 80-601-0020-00 ________ 187 80-601-0021-00 ________ 187 80-601-0022-00 ________ 187 80-601-0023-00 ________ 187 80-601-0024-00 ________ 187 80-601-0025-00 ________ 187 80-601-0026-00 ________ 187 80-700-0047-00 ________ 104 80-700-0048-00 ________ 104 80-700-0050-00 ________ 104 80-700-0051-00 ________ 104 80-700-0052-00 ________ 104 80-700-0053-00 ________ 104 80-700-0054-00 ________ 106 80-700-0055-00 ________ 106 80-701-0018-00 _________ 97 80-707-00004-00 _______ 180 80-707-00005-00 _______ 180 80-708-0013-00 _________ 96 80-708-0017-00 _________ 96 80-712-0039-00 ________ 117
80-712-0039-01 ________ 117 80-716-0014-00 ________ 104 80-716-0015-00 ________ 104 80-716-0016-00 ________ 104 80-716-0017-00 ________ 103 80-716-0018-00 ________ 103 80-724-0006-00 _________ 96 80-724-0007-00 _________ 97 80-911-0001-00 ________ 166 80-911-0002-00 ________ 166 80-911-0003-00 ________ 166 80-911-0004-00 ________ 166 80-911-0005-00 ________ 173 80-911-0006-00 ________ 173 80-911-0007-00 ________ 175 80-911-0008-00 ________ 175 80-911-0009-00 ________ 174 80-911-0010-00 ________ 174 80-911-0011-00 ________ 171 80-911-0012-00 ________ 171 80-911-0013-00 ________ 172 80-911-0014-00 ________ 172 80-911-0016-00 ________ 178 80-911-0017-00 ________ 178 80-911-0018-00 ________ 179 80-911-0019-00 ________ 179 80-911-0020-00 ________ 179 80-911-0021-00 ________ 179 80-911-0022-00 ________ 179 80-911-0023-00 ________ 179 80-911-0024-00 ________ 177 80-911-0025-00 ________ 177 80-911-0026-00 ________ 177 80-911-0027-00 ________ 177 80-911-0028-00 ________ 177 80-911-0029-00 ________ 177 80-911-0030-00 ________ 177 80-911-0031-00 ________ 177 80-911-0032-00 ________ 177 80-911-0033-00 ________ 178 80-911-0034-00 ________ 178 80-911-0035-00 ________ 178
286
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Index
80-911-0036-00 ________ 178 80-911-0037-00 ________ 179 80-911-0038-00 ________ 179 80-911-0039-00 ________ 179 80-911-0040-00 ________ 179 80-911-0041-00 ________ 178 80-911-0042-00 ________ 178 80-911-0043-00 ________ 178 80-911-0044-00 ________ 179 80-911-0045-00 _____ 96, 179 80-911-0046-00 ________ 177 80-911-0047-00 ________ 177 80-911-0048-00 ________ 177 80-911-0049-00 ________ 177 80-911-0050-00 ________ 177 80-911-0051-00 ________ 177 80-911-0052-00 ________ 178 80-911-0053-00 ________ 178 80-911-0054-00 ________ 178 80-911-0057-00 ________ 180 80-911-0060-00 ________ 179 80-911-0061-00 ________ 179 80-911-0062-00 ________ 179 80-911-0063-00 ________ 179 80-911-0064-00 ________ 166 80-911-0065-00 ________ 166 80-911-0066-00 ________ 179 80-911-0068-00 ________ 168 80-911-0069-00 ________ 169 80-911-0071-00 ________ 179 80-911-0072-00 ________ 180 80A ____________________ 19 81200100 _______________ 78 81300100 _______________ 78 81300200 _______________ 78 81300300 _______________ 78 81300400 _______________ 78 81400100 _______________ 77 81400200 _______________ 77 81400300 _______________ 77 81400330 _______________ 77 81400350 _______________ 77
81400400 _______________ 77 81400500 _______________ 77 81400600 _______________ 77 81400700 _______________ 77 81400800 _______________ 77 81500100 _______________ 76 81500200 _______________ 76 81500300 _______________ 76 81500350 _______________ 76 81500400 _______________ 76 81500500 _______________ 76 81500600 _______________ 76 81500700 _______________ 76 81A ____________________ 19 82011 _________________ 236 82012 _________________ 236 82081 _________________ 236 82082 _________________ 236 82112 _________________ 236 82181 _________________ 236 82182 _________________ 236 82212 _________________ 236 82312 _________________ 236 83007021 ______________ 113 83007030 ______________ 113 83012021 ______________ 113 83012031 ______________ 113 83116025 ______________ 113 83116035 ______________ 113 83125035 ______________ 113 83200150 ______________ 114 83301202 _______________ 99 83302502 _______________ 99 83A ____________________ 19 84A ____________________ 19 85000600 _______________ 82 85000800 _______________ 82 85001000 _______________ 82 85001300 _______________ 82 86050351 _______________ 82 88000350 _______________ 82 88000705 _______________ 82
900-2WPMoM__________ 141 900-2WPofo __________ 141 900-2WP ______________ 141 900-3WPSW ___________ 139 900-3WPS _____________ 139 900-4WPW _____________ 139 900-4WP ______________ 139 900-5WPSW ___________ 139 900-5WPS _____________ 139 900-6WPW _____________ 139 900-6WP ______________ 139 900-AC1-110V _________ 130 900-AC1 _______________ 130 900-AC2h-ACSM-110 ___ 131 900-AC2h-ACSM _______ 131 900-AC2h-AM-110______ 131 900-AC2h-AM__________ 131 900-AC2V-ACSM-110 ___ 131 900-AC2V-ACSM _______ 131 900-AC2V-AM-110 ______ 131 900-AC2V-AM __________ 131 900-AC3-ACSM ________ 131 900-AC3-AM-110 _______ 131 900-AC3-AM ___________ 131 900-AC3-ASCM-110 ____ 131 900-AC4-ACSM-110 ____ 131 900-AC4-ACSM ________ 131 900-ACCh-110V ________ 130 900-ACCh _____________ 130 900-ACM2-AM-110 _____ 131 900-ACM2-AM _____ 130, 131 900-ACM2W-110V ______ 130 900-ACM2W ___________ 130 900-ACM6V-AM-110 ____ 131 900-ACM6V-AM ________ 131 900-ACM6W-110V ______ 130 900-ACM6W ___________ 130 900-AM________________ 126 900-AM _______________ 126 900-BA ________________ 141 900-DC ________________ 124 900-RCD-16A __________ 122
Index
900-RCD-2X16A ________ 122 900-RCD-2X32A ________ 122 900-RCD-32A __________ 122 900-SoP_______________ 141 900V-DCSM ___________ 126 900 ___________________ 273 901h __________________ 124 901V-AM ______________ 126 901V-DCSM ____________ 126 901V __________________ 124 902-AM________________ 126 902-DCSM _____________ 126 902NMh _______________ 124 902NMV _______________ 124 902V-AM ______________ 126 902V-DCSM ____________ 126 902 ___________________ 273 903-5 _________________ 273 903-AM________________ 126 903-DCSM _________ 126, 127 904-AM________________ 126 904-DCSM _____________ 126 904NMh _______________ 124 904NMV _______________ 124 904NM ____________ 124, 125 905-AM____________ 126, 127 905-DCSM _____________ 126 905NMV ___________ 124, 125 905NM ____________ 124, 125 905V-AM ______________ 126 905V-DCSM ____________ 126 906-AM____________ 126, 127 906-DCSM _____________ 126 906NMh ___________ 124, 125 906NMV ___________ 124, 125 906V-AM ______________ 126 906V-DCSM ____________ 126 907-AM____________ 126, 127 AC-VSeN-4 ________ 180, 182 ATC-6W/B _____________ 117 ATC-6WQC/B __________ 117
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
287
Index
ATC-6WQC ____________ 117 ATC-6W _______________ 117 BAG ___________________ 26 BB-12W-2NC/DSP ______ 145 BB-12W-2NC___________ 145 BB-12W-2S/DSP ________ 145 BB-12W-2S ____________ 145 BB-24W-2S/DSP ________ 145 BB-24W-2S ____________ 145 BB-4S-150A/DSP _______ 145 BB-6W-2NC/DSP _______ 145 BB-6W-2NC ____________ 145 BB-6W-2S/DSP _________ 145 BB-6W-2S _____________ 145 BB-6W-2_______________ 146 BB-LINk17MM _________ 117 BBC-12WBk ___________ 145 BBC-12WR ____________ 145 BBC-24WBk ___________ 145 BBC-24WR ____________ 145 BBC-6WBk ____________ 145 BBC-6WR______________ 145 BC-fM1 _______________ 132 BC-fM2 _______________ 132 BC-fM3 _______________ 132 BC-fM4 _______________ 132 BC-PM1 _______________ 132 BC-PM2 _______________ 132 BfhD-30A/DSP_________ 116 BfhD-30A _____________ 116 BfhD-40A/DSP_________ 116 BfhD-40A _____________ 116 BfhD-50A/DSP_________ 116 BfhD-50A _____________ 116 BfhD-60A/DSP_________ 116 BfhD-60A _____________ 116 BfhD-70A/DSP_________ 116 BfhD-70A _____________ 116 BfhD-80A/DSP_________ 116 BfhD-80A _____________ 116 BL-SL-L _______________ 185 CBL-100A-DP __________ 119
CBL-100A-SP ______ 112, 119 CBL-50A-DP ___________ 119 CBL-50A-SP _______ 112, 119 CBL-60A-DP ___________ 119 CBL-60A-SP ___________ 119 CBL-75A-DP ___________ 119 CBL-75A-SP _______ 112, 119 CBS-20A-DP-TC230 ____ 130 CBS-50A-DP ___________ 119 CBS-50A-SP-IG ________ 119 CC-12VRC _____________ 106 CC-1 __________________ 108 CC-3WS/Ch ___________ 108 CC-5 __________________ 108 CC-801 ____________ 105, 106 CC-802 ____________ 105, 106 CC-803N __________ 105, 106 CC-804 ________________ 107 CC-805PR _____________ 107 CC-805T_______________ 107 CC-806PR _____________ 107 CC-807PR _____________ 107 CC-807T-PR____________ 107 CC-807T_______________ 107 CC-810 ____________ 105, 106 CC-811PR _________ 106, 107 CC-811T___________ 106, 107 CC-BLANk ____________ 106 CC-hDBM _____________ 108 CG2-2W-f-W ___________ 140 CG2-2W-f _____________ 140 CG2-2W-W ____________ 140 CG2-2W _______________ 140 CG2-4W-f-W ___________ 140 CG2-4W-f _____________ 140 CG2-4W-W ____________ 140 CG2-4W _______________ 140 CG2-6W-f-W ___________ 140 CG2-6W-f _____________ 140 CG2-6W-W ____________ 140 CG2-6W _______________ 140 CG2-JB _______________ 140
CLB-05/DSP ___________ 120 CLB-05 ________________ 120 CLB-10/DSP ___________ 120 CLB-10 ________________ 120 CLB-15/DSP ___________ 120 CLB-15 ________________ 120 CLB-20 ________________ 120 CLB-25/DSP ___________ 120 CLB-30 ________________ 120 CLB-40/DSP ___________ 120 CLB-40 ________________ 120 CLB-BooT/DSP ________ 120 CLB-BooT ____________ 120 CLIP-01 ________________ 26 CLIP ___________________ 26 CMP-4WP _____________ 139 CMP-5WPS ____________ 139 CMP-6WP _____________ 139 CSP6-f ________________ 141 CSP6-PTC _____________ 141 CSP6__________________ 141 CT-10-3____________ 180, 182 CT-hD _____________ 180, 182 CW-290 _______________ 214 CW-T1M50_____________ 214 CW-T1RR50____________ 214 CW-T2M25_____________ 214 CW-T2M75_____________ 214 CW-T2R2 ______________ 214 CW-T2RR25____________ 214 CW-T2T3R2 ____________ 214 CW-T3M25_____________ 214 CW-T3M50_____________ 214 CW-T3R2 ______________ 214 CW-T3RR25____________ 214 CW-T4M20_____________ 214 CW-T4RR20____________ 214 DM6250 _______________ 220 DM6450 _______________ 221 DP PANeL _____________ 128 DSA1020TRMS _________ 220 DSA540A ______________ 219
eT6207 ________________ 218 eT64220 _______________ 218 fD-2 __________________ 185 G30 ____________________ 22 GAS-SM _______________ 181 hDBfh ________________ 116 hSP5__________________ 219 INLeT.LABeL.30A________ 27 INLeT.LABeL.50A________ 27 IP100/DSP _____________ 116 IP100A ________________ 116 IP150/DSP _____________ 116 IP150A ________________ 116 IP200/DSP _____________ 116 IP200A ________________ 116 IP250/DSP _____________ 116 IP250A ________________ 116 IP300/DSP _____________ 116 IP300A ________________ 116 IP425/DSP _____________ 116 IP425A ________________ 116 IP500/DSP _____________ 116 IP500A ________________ 116 IP80/DSP ______________ 116 IP80A _________________ 116 IS-10MM-1/DSP ________ 147 IS-10MM-1R/DSP _______ 147 IS-10MM-1R ___________ 147 IS-10MM-1 _____________ 147 IS-10MM-2/DSP ________ 147 IS-10MM-2/L/DSP _______ 147 IS-10MM-2/L ___________ 147 IS-10MM-2 _____________ 147 IS-10MM-8MM/DSP _____ 147 IS-10MM-8MM _________ 147 IS-6MM-1/DSP _________ 147 IS-6MM-1R/DSP ________ 147 IS-6MM-1R_____________ 147 IS-6MM-1 ______________ 147 IS-6MM-2/DSP _________ 147 IS-6MM-2 ______________ 147 IS-8MM-1/DSP _________ 147
288
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
Index
IS-8MM-1R/DSP ________ 147 IS-8MM-1R_____________ 147 IS-8MM-1 ______________ 147 ISC-10Bk-S ____________ 147 ISC-10Bk ______________ 147 ISC-10R-S _____________ 147 ISC-10R _______________ 147 ISC-6-2 ________________ 147 J03A __________________ 115 J05A __________________ 115 J10A __________________ 115 J15A __________________ 115 J20A __________________ 115 J25A __________________ 115 J30A __________________ 115 J7.5A _________________ 115 JJ05A _________________ 115 JJ10A _________________ 115 JJ15A _________________ 115 JJ20A _________________ 115 JJ30A _________________ 115 LB-450-50 _________ 179, 181 LBL-MIC1______________ 137 LBL-MICSyM___________ 137 LD-6R-120-Ce__________ 108 LD-6R-150-BD _________ 108 LD-6R-210-BD _________ 108 LD-6R-300-BD _________ 108 M28-DCSM ________ 126, 129 M32-DCSM ____________ 129 M4100C12R ____________ 32 M4100C12 ______________ 32 M4100P12 ______________ 32 M4100R12 ______________ 32 M44-DCSM ____________ 129 M44h-DCSM ___________ 129 M5100B9R ______________ 32 M5100C9R______________ 32 M5100C9 _______________ 32 M5100P9 _______________ 32 M5100R9 _______________ 32 M56-DCSM ____________ 129
MCB16A_______________ 122 MCB32A_______________ 122 MCB63A_______________ 122 MCB-3WeNC __________ 122 ML-005BW-STC ________ 260 ML-005BW/DSP ________ 260 ML-005NWW ___________ 261 ML-005WW-STC ________ 260 ML-005WW/DSP ________ 260 N0100ACT _____________ 186 N0100A _______________ 186 N010A ________________ 186 N0150ACV _____________ 186 N0150A _______________ 186 N020A ________________ 186 N0300ACV _____________ 186 N050A ________________ 186 N060ACT ______________ 186 N10863DW ____________ 272 N10863________________ 271 N10864DW ____________ 272 N10864________________ 271 N10866________________ 272 N10867________________ 272 N10869________________ 272 N10870________________ 272 N10873________________ 272 N10874________________ 272 N10963________________ 271 N10964________________ 271 N1632DCV_____________ 186 N20020________________ 270 N20030________________ 270 N20703S ______________ 270 N20703W ______________ 270 N20704S ______________ 270 N20704W ______________ 270 N20790________________ 270 N28810________________ 271 N28830____________ 270, 271 N816DCV ______________ 186 NC32y-AM _____________ 128
NC32y-DCSM __________ 128 NC36L-AM _____________ 128 NC36L-DCSM __________ 128 NC36NM __________ 124, 125 NCB-CC _______________ 108 No100A _______________ 186 No300ACV ____________ 186 No60ACT _____________ 186 P33307 ________________ 216 P-11D03 _______________ 114 P-11D04 _______________ 114 P-12D34 _______________ 114 P-12D35 _______________ 114 P-12D36 _______________ 114 P-12D37 _______________ 114 P-13A27 _______________ 114 P-13A28 _______________ 114 P-13A29 _______________ 114 P-13A2A _______________ 114 P-14302 ___________ 260, 261 Ph6444TV ______________ 15 Ph6574TV.oeM _________ 15 Ph6574TV.W/L __________ 15 Ph6574TV ______________ 15 Ph6592TV-SS.oeM ______ 15 Ph6592TV-SS ___________ 15 Ph6597TV.oeM _________ 16 Ph6597TV ______________ 16 Ph6597 ________________ 16 Ph6599-25______________ 16 Ph6599 ________________ 16 Ph6600 ________________ 15 Ph6601 ________________ 15 Ph6629 ________________ 15 PhTV6599-25 ___________ 16 PhTV6599 ______________ 16 RCD16A30MA__________ 122 RCD32A30MA__________ 122 RCD63A30MA__________ 122 ReS-12WAy ____________ 125 ReS-16WAy ____________ 125 ReS-20WAy ____________ 125
Index
ReS-28WAy ____________ 125 ReS-32WAy ____________ 125 ReS-36WAy ____________ 125 ReS-44WAy ____________ 125 ReS-4WAy ____________ 125 ReS-56WAy ____________ 125 ReS-8WAy ____________ 125 RV-TG-2T ______________ 183 RV-TG-3T ______________ 183 RV-TG _________________ 183 RV-TS-5M ______________ 183 Ry504-2-30 _____________ 21 SA296CoMP-12 ________ 185 SeT-1001 ______________ 137 SeT-1002 ______________ 137 SeT-10N _______________ 133 SeT-12N _______________ 133 SeT-13N _______________ 134 SeT-14N _______________ 134 SeT-15N _______________ 134 SeT-16N _______________ 134 SeT-17N _______________ 134 SeT-18N _______________ 134 SeT-19N _______________ 134 SeT-1N ________________ 133 SeT-1SP/f _____________ 135 SeT-20N _______________ 134 SeT-22N _______________ 134 SeT-23N _______________ 134 SeT-2N ________________ 133 SeT-2SP _______________ 135 SeT-3N ________________ 133 SeT-4N ________________ 133 SeT-5N ________________ 133 SeT-6N ________________ 133 SeT-714 _______________ 135 SeT-715 _______________ 136 SeT-7N ________________ 133 SeT-8N ________________ 133 SeT-9N ________________ 133 SeT-CC-1 ______________ 136
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
289
Index
SeT-CC-A ______________ 136 SeT-CC-BCC-1 _________ 136 SeT-fReNCh 2 _________ 134 SeT-fReNCh___________ 134 SeT-G2-1 ______________ 137 SeT-G2-2 ______________ 137 SeT-IN_________________ 135 SeT-MSP3 _____________ 135 SeT-MSP4 _____________ 135 SeT- LBL-CMP _________ 135 SeT- LBL-WP ___________ 135 SoP1-AL ______________ 186 SoP1 _________________ 186 SoP2-AL ______________ 186 SoP2 _________________ 186 SPC103 _______________ 199 SPL-12B.oeM __________ 257 SPL-12B _______________ 257 SPL-12C.oeM __________ 257 SPL-12C _______________ 257 SPL-12W.oeM _________ 257 SPL-12W ______________ 257 SPL-24B.oeM __________ 257 SPL-24C.oeM __________ 257 SPL-24W.oeM _________ 257 SPRL-1 ________________ 257 SPRL-2 ________________ 257 SPRL-3 ________________ 257 SW-32111 _____________ 139 SW-32113 _____________ 139 SW-32114 _____________ 139 SW-32115 _____________ 139 SW-32120 _____________ 139 SW-32123 _____________ 139 SW-6064B3P ___________ 143 SW-6064C3P ___________ 143 SW-6064D3P ___________ 143 SW-CG1 _______________ 140 SW-CG2 _______________ 140 SW-CG3 _______________ 140 SW-CG4 _______________ 140 SW-CG5 _______________ 140
SW-M331 ______________ 139 SW-RVS2 ______________ 142 TB-118-10P ____________ 147 TB-118-6P _____________ 147 TS1-Pk ________________ 184 TS1 ___________________ 184 TV6444 _________________ 15 TV6574 _________________ 15 TV6592 _________________ 15 TV97.oeM ______________ 16 TV97 ___________________ 16 TVhD __________________ 16 u-3605 ________________ 261 u-3606 ________________ 261 uSBA6.oeM ____________ 16 uSBA6 _________________ 16 VR2.2 _________________ 185 WAfh-14 ______________ 139 zIP-01 __________________ 26
290
MASTERVOLT | mastervolt.us
MARINCO | marinco.com
55 Paul Matthews Road Albany, Auckland 0632 New Zealand +64 9 415 7261 +64 9 415 9327 fax
Mastervolt International BV Snijdersbergweg 93 1105 AN AMSTERDAM ZO The Netherlands +31(0)20 34 22 100 +31(0)20 69 71 006 fax
N85 W12545 Westbrook Crossing Menomonee Falls, WI 53051 800.307.6702 800.799.3779 fax
Today, Actuant Electrical provides electrical tools, transformers, sockets and switches, wiring devices and other power management products for the professional, retail/do-it-yourself (DIY), harsh environment, marine, and diverse OEM end-market channels. Our focus is to create innovative electrical products using consistent, high quality processes. We deliver these products wherever our customers need them, anywhere in the world. Whether we power life-saving medical machines or alternative energy sources or create electrical products for marine on-board applications or industrial environments, the varied experience behind our products translates into quality for our customers. actuant.com/electrical
MAR_CAT_003_0911