Sie sind auf Seite 1von 2

E

IEEE693

CA-M
CC-M
CX-M

HS

2S

HIGH SEISMIC

036

2 STEP

Battery Rack
ECHS2S

RACK LENGTH
IN INCHES

SUFFIX:
A = 2 Galvanized Rails per Step (Standard)
AP = 2 Painted Rails per Step
A3R = 3 Galvanized Rails per Step
A3RP = 3 Painted Rails per Step

3 FRAME RACK SHOWN

LENGTH
ft
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

in
36
48
60
72
84
96
108
120
132
144
156
168
180
192
204
216
228
240

CATALOG NO.
mm
914
1219
1524
1829
2134
2438
2743
3048
3353
3658
3962
4267
4572
4877
5182
5486
5791
6096

ECHS2S036A
ECHS2S048A
ECHS2S060A
ECHS2S072A
ECHS2S084A
ECHS2S096A
ECHS2S108A
ECHS2S120A
ECHS2S132A
ECHS2S144A
ECHS2S156A
ECHS2S168A
ECHS2S180A
ECHS2S192A
ECHS2S204A
ECHS2S216A
ECHS2S228A
ECHS2S240A

L
in
36.00
48.00
60.00
72.00
84.00
96.00
108.00
120.00
132.00
144.00
156.00
168.00
180.00
192.00
204.00
216.00
228.00
240.00

mm
914.4
1219.2
1524.0
1828.8
2133.6
2438.4
2743.2
3048.0
3352.8
3657.6
3962.4
4267.2
4572.0
4876.8
5181.6
5486.4
5791.2
6096.0

DIMENSIONS
A
in
mm
6.00 152.4
9.00 228.6
12.00 304.8
9.00 228.6
9.00 228.6
15.00 381.0
9.00 228.6
10.50 266.7
12.00 304.8
12.00 304.8
12.00 304.8
12.00 304.8
15.00 381.0
13.50 342.9
12.00 304.8
9.00 228.6
15.00 381.0
12.00 304.8

C
in
24.00
30.00
36.00
27.00
33.00
33.00
30.00
33.00
36.00
30.00
33.00
36.00
30.00
33.00
36.00
33.00
33.00
36.00

mm
609.6
762.0
914.4
685.8
838.2
838.2
762.0
838.2
914.4
762.0
838.2
914.4
762.0
838.2
914.4
838.2
838.2
914.4

UNPACKED
WEIGHT
lbs
kg
237
107.5
256
116.1
273
123.8
385
174.6
403
182.8
420
190.5
532
241.3
551
249.9
570
258.6
682
309.4
699
317.1
719
326.1
830
376.5
847
384.2
867
393.3
978
443.6
995
451.3
1016
460.9

PACKED
WEIGHT
lbs
kg
287 130.2
306 138.8
323 146.5
435 197.3
453 205.5
470 213.2
582 264.0
601 272.6
620 281.2
782 354.7
799 362.4
819 371.5
930 421.8
947 429.6
967 438.6
1078 489.0
1095 496.7
1116 506.2

FRAME
QTY.
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7

RACK SPECIFICATIONS:
FRAMES:
RAILS:
RAIL INSULATION:
HARDWARE:
ANCHOR LOADS:

Steel members covered with ANSI 61 gray acid-resistant polyester powder coating
Galvanized rails are standard, refer to suffix list for available options
Plastic channel fastened with double-sided tape
Zinc-plated steel
Minimum Shear Force: 650 lbf
Minimum Tension Force: 175 lbf

RACK NOTES:
1. Each seismic rack must stand alone with a minimum clearance of 4.0 inches (102 mm) from any other object (walls, other racks, etc.).
2. Racks are shipped unassembled. All necessary assembly hardware is included. Anchor bolts are not supplied. Refer to Installation Manual
included with the rack shipment.
3. Each frame must be anchored to the floor. Holes are provided at the base of each frame. Please refer to anchor location diagram for hole size
and spacing. Design of the anchoring system is the responsibility of the customer.
4. To select the proper rack, refer to the chart on the reverse side of this sheet.

Publication No. US-ECHS2S-RK-01 June 2011

LENGTH
ft

in

mm

3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

36
48
60
72
84
96
108
120
132
144
156
168
180
192
204
216
228
240

914
1219
1524
1829
2134
2438
2743
3048
3353
3658
3962
4267
4572
4877
5182
5486
5791
6096

CA-M, CC-M, CX-M


MAXIMUM NUMBER OF UNITS PER RACK
CA-3M to 5M
CA-7M to 9M
CC-3M to 5M
CC-7M to 9M
CX-5M to 7M
CX-9M to 15M
8
4
12
6
14
8
18
10
22
12
24
14
28
16
30
18
34
20
38
22
40
24
44
26
48
28
50
30
54
32
58
34
60
36
64
38

Publication No. US-ECHS2S-RK-01 June 2011 Subject to revisions without prior notice. E.&O.E.

ECHS2S

ANCHOR LOCATION DIAGRAM, 3 FRAME RACK SHOWN

EnerSys
P.O. Box 14145
Reading, PA 19612-4145
USA
Tel: +1-610-208-1991
+1-800-538-3627
Fax: +1-610-372-8613
www.enersys.com

EnerSys EMEA
Brussels, Belgium
Tel: +32 (0)2 247 94 47

Represented by:

EnerSys Asia
Guangdong, China
Tel: +86 755 2689 3639
Printed in USA
2011 EnerSys. All rights reserved.
Trademarks and logos are the property of
EnerSys and its affiliates except ISO, which is not the
property of EnerSys.

Das könnte Ihnen auch gefallen