INSTALLATION MANUAL polistream A1000

sales@screen.subtitling.com support@screen.subtitling.com Support direct line: +44 (0)1473 834534

screen subtitling systems

world class subtitling solutions

A1000 Installation manual

Copyright Screen Subtitling Systems Ltd 2002


All rights reserved. Neither the whole nor any part of the information contained in this manual may be adapted or reproduced in any material form except with the prior written permission of Screen Subtitling Systems Ltd.

Issue 1
December 2002 This product was designed and built to satisfy the requirements of ENBS60950 (electrical safety). In order to maintain compliance with the standards EN55022 Class A (emissions) and EN50082-1 (immunity) this unit must be connected using properly earthed and fully screened cables. Screen Subtitling Systems Ltd A1000 Installation manual Page 1 of 9

Introduction
The A1000 belongs to the Polistream product range and is a robust 1U rack mounting, high performance ASI input platform specifically designed for use within a Polistream subtitling system. The A1000 is typically used for the extraction of Program Clock Reference (PCR) values from an incoming ASI stream. These PCR values would then be used to generate the Presentation Time Stamp (PTS) values for the outgoing subtitles. In addition to PCR extraction, the A1000 can filter incoming ASI packets by PID for system monitoring purposes. The A1000 is based on proven and standard PC architecture and operating systems. This ensures the highest performance is achieved with the greatest degree of flexibility in configuration and use. The A1000 is connected to the Polistream system using a standard 10/100baseT Ethernet network. It is recommended that Ethernet switches (not simple Ethernet hubs) are used where required. The A1000 has a rear panel mounted connector for an optional external floppy drive (for configuration purposes). There are no user configurable switches, links or front panel controls (with the exception of a soft power push-button switch), and all A1000 configuration and operation is done (either locally or remotely) via Ethernet from controlling client applications. The front panel of the A1000 is fitted with unit status LED indicators, and Ethernet port status LED indicators are fitted to the rear panel RJ45 connector. This manual covers the installation requirements of the A1000, as well as providing information on unit and system configuration and connection.

Operation
Once an A1000 has been correctly installed with respect to the contents of this installation manual, the operation of the unit is controlled entirely by the various Polistream applications.

Screen Subtitling Systems Ltd

A1000 Installation manual Page 2 of 9

Installation
Siting requirements Physical
Mounting: Standard 480mm (19in) rack bay. The A1000 is secured by four fixing screws through the front panel. It is recommended that the rear of the unit is supported to prevent damage to the front panel fixing lugs. 44mm 1U. No ventilation space is required above or below. The overall depth of the unit is 425mm. Adequate space should be allowed behind the unit for connections to be made without imposing strain on the cables or connectors. Forced air ventilation across the unit from right to left (viewed from front of unit). The ventilation slots on either side and the rear of the chassis, must not be obstructed in any way.

Vertical Space: Rear space:

Air Flow:

Electrical
The A1000 is fitted with an IEC mains connector. Please note: There is no mains power switch fitted to the A1000 with the exception of the front panel mounted soft power push-button switch. The internal power supply is an auto ranging unit, which can accept AC mains input voltages between 100 and 240V (50/60Hz), with no user configuration or adjustment required. The power consumption is 84W (typically). Warning: Do not remove the top cover while the unit is connected to the mains supply. There is a risk of lethal electric shock from internal components.

Environmental
There are no special environmental requirements, but the normal precautions regarding the operation of electrical equipment should be observed. In particular, ensure that the ambient operating temperature is maintained within the limits of 0C to 30C at a relative humidity not exceeding 90% non-condensing.

Unit configuration
All A1000 configuration is done (locally or remotely) via Ethernet using various Polistream applications. There are no user configurable internal switches or links fitted.

Screen Subtitling Systems Ltd

A1000 Installation manual Page 3 of 9

Rear panel
The diagram below illustrates the rear panel connections found on the A1000 ASI input and output platform.
1 2 3 4 5 13 14

AC IN

Mouse

Ethernet Printer MIDI I/O

Floppy Drive

ASI IN

USB 0 KYB 1 COM 1 VGA Sound I/O

COM 2

Power Fail

10

11

12

Figure 1: A1000 rear panel 1. Mains power inlet (IEC320). 2. Mouse port for connection to a standard PS/2 style mouse. 3. Ethernet (RJ45) provides the 10/100 BaseT connection to the Polistream system via an Ethernet switching hub. This Ethernet connection must be made across a dedicated network and should be isolated from heavy traffic networks such as corporate IT systems. Ethernet Link (green) and Activity (orange) LEDs are fitted to this connector. 4. Printer port provides a standard PC parallel printer port for normal / EPP / ECP printers. 5. Midi I/O not currently used on the A1000. 6. Keyboard for connection to a standard PS/2 style keyboard. 7. USB not currently used on the A1000. 8. Com 1 provides a standard PC RS232 serial port. 9. VGA provides a standard PC SVGA monitor output. 10. Sound I/O not currently used on the A1000. 11. Com 2 provides a second RS232 serial port. 12. Power Fail provides contact closure relay signalling in the event of a unit power failure. 13. Floppy Drive provides connection for an external 3.5in floppy disc drive. 14. ASI input provides an ASI input connection (MPEG-2 DVB) on a 75 ohm BNC connector. Once installed, an A1000 will generally require only Power, Ethernet and an ASI input connection. Please note: In order to maintain compliance with standards EN55022 Class A (emissions) and EN50082 1 (immunity), the A1000 must be connected using properly earthed and fully screened cables.

Screen Subtitling Systems Ltd

A1000 Installation manual Page 4 of 9

Front panel
The diagram below illustrates the unit status LED indicators and soft power push-button switch fitted to the front panel of the A1000. There are no other front panel controls fitted to the unit.

Power On
Soft Power push-button switch Controls the mains input. Press and hold for 5 seconds for soft power off.

Disk
Figure 2: Front panel LED indicators

The LED indicators display the following unit status: Power On Green LED This LED is on when the A1000 is powered up. Disk Yellow LED This LED is on when the internal HDD is being accessed.

Screen Subtitling Systems Ltd

A1000 Installation manual Page 5 of 9

System configuration
A typical operational configuration for the A1000 ASI input platform within a Polistream system is shown below.

Ethernet Switch

P5000 processing platform ISDN phone line P4000 processing platform Configuration Manager

Automation either Serial or IP

VITC or LTC Timecode

Program Manager Polistream Configurable Software Modules

Workstation

Configuration Client Polistream Monitoring A1000 ASI input platform

ASI I/P

Program Manager Polistream ASI RX Software

Subtitle server
Figure 3: Typical A1000 configuration within a DVB Polistream system The illustration shows a typical Polistream subtitling system with a P5000 central server, a P4000 running various configurable software modules, and an A1000 ASI input platform. The A1000 platform would run the Program Manager application and a Polistream Configurable Software Module such as High Bandwidth ASI RX. The illustration also shows the Configuration Client workstation running a Polistream monitoring application such as MSX. However, Polistream system monitoring can be done either locally, or remotely via a WAN or P5000 ISDN connection.

Screen Subtitling Systems Ltd

A1000 Installation manual Page 6 of 9

Troubleshooting
The A1000 is extremely reliable and stable, and will rarely need attention during its normal service life. However, in the event of an operational problem, it is advisable to check all associated equipment and cabling. It is also worth restarting the unit by closing all open applications and cycling the power to the A1000 using the soft power push-button switch. The following guide may help identify possible causes to operational problems. However, if these measures fail to locate the problem please contact your local dealer or Screen Subtitling Systems support team. Observed problem Power On LED not lit. Possible remedial action Check local power supply voltage and IEC connector at the rear of the A1000 chassis. HDD activity should occur during unit start up, cycle power and observe LED for activity. Check green Link LED to ensure unit is connected to the Ethernet network correctly. Check network connections to and from the Ethernet switch.

HDD activity LED not lighting.

Network activity LED not lighting.

Table 1: Troubleshooting guide

Screen Subtitling Systems Ltd

A1000 Installation manual Page 7 of 9

Signal Specifications
Rear panel connectors (PC99 specification)
1 x RJ45 10/100BaseT 1 x 9 way D type (male) 2 x PS/2 type mini DIN 1 x 15 way Hi-density D type (female) 1 x 15 way D type (female) 1 x 25 way D type (female) 3 x 3.5mm sockets 2 x USB connectors Ethernet RS232 serial (Com 1) Mouse and Keyboard SVGA monitor MIDI I/O (not currently used) Printer (normal/EPP/ECP) Sound I/O (not currently used) USB 0 1 (not currently used)

Additional RS232 serial port


1 x 9 way D type (male) connector (Com 2) Pin 1 2 3 4 5 Function Carrier Detect CD Receive Data RXD Transmit Data TXD Data Terminal ready DTR Signal Ground GND Pin 6 7 8 9 Function Data Set Ready DSR Request To Send RTS Clear To Send CTS Ring Indicator RI

Power fail signalling


1 x 9 way D type (female) connector Pin Function Pin Function 1 NC Contact 1 6 Common Contact 1 2 NO Contact 1 7 NC Contact 2 3 Common Contact 2 8 NO Contact 2 4 Not Used 9 +5V (50mA max) 5 Ground Power fail signalling by contact closure (contact rating 2A@48V DC or AC)

Floppy drive
1 x 37 way D type (female) connector (proprietary pin out)

ASI input
1 x High speed (270Mb/s) DVB MPEG-2 ASI Transport Stream (TS) input on 75 ohm BNC connector.

Screen Subtitling Systems Ltd

A1000 Installation manual Page 8 of 9

Screen Subtitling Systems Ltd The Old Rectory Church Lane Claydon Ipswich Suffolk IP6 0EQ United Kingdom Tel: +44 (0) 1473 831700 Fax: +44 (0) 1473 830078 Email: sales@screen.subtitling.com support @screen.subtitling.com

www.screen.subtitling.com
Screen Subtitling Systems Ltd A1000 Installation manual Page 9 of 9