Sie sind auf Seite 1von 2

we ANCHOR industry

DECO HEAV Y- D U T Y A D J U S TABLE ANCHORS

Deco Heavy-Duty Adjustable Anchors durable, heavy-duty anchor studs and couplings are machined from mill-tested, C1144 (A-311) stress-proof, cold-rolled steel having a minimum tensile strength of 115,000 lbs. psi and yield strength of 100,000 lbs. psi. Special orders from alloy steel are available with a yield strength of 130,000 lbs. psi.

eco Heavy-Duty Adjustable Anchors are also available in stainless or galvanized steel for specic industrial applications. To best meet our customers needs, Deco also offers specialty steels and coatings. Multiple anchors may be installed in sole plates to customers specications. Stepped couplings are available for jobs that require fastening studs and lower studs of different diameters. Leveling plates of any size may be specified on Deco Heavy-Duty Adjustable Anchors.

D I M E N S I ON S
Bolt Diameter Threads Per Inch Tube Diameter Fastening Stud Box Height Box Square Plate Thickness B C D E F 114 334
3

8
9

1 8 234

118 7 3

114 7 3

138 6 3

112 6 3

134 5 312

2 412 4

214 412 412

212 4 5

234 4 5

3 4 512

13 2

11 2

10 212

212

B 2xA

with 1 nut and washer

Length to Specifications 114 334


3

112 434
3

112 434
3

134 5 534
3

214 5 534
3

214 5 534
3

214 5 534
3

214 5 534
3

234 534 614


1

234 714
1

314 714
1

334 814
1

334 914
1

434 914
1

3xA

A
As Required Equal to

A F

D E

Page 1

TOLL FREE PHON E FA X

800-637-5861 217-872-6450 217-872-6455

www.DECOanchors.com DECOmfg@aol.com
3268

DECO HEAV Y- D U T Y ADJUSTABLE ANCHORS PERFORMANCE


1 Safe working loads are based on a 4,000 lbs. psi concrete compressive strength at 28 days and a safety factor of 4 against predicted ultimate loads. Safe working loads are for anchors loaded in a static condition. For a dynamic loading condition, reduce loads by a minimum of 50%. 5 Anchor Bolt Combined Stress Interaction Formula: Actual Tension Applied Safe Working Load Allowable Pullout Actual Shear Applied Safe Working Load Allowable Shear

2 Shear safe working loads can only be obtained by fully grouting the annular space of the sleeve tube. 3 Allowable minimum center-to-center spacing of 12 times anchor diameter is permissible using a reduced safe working load of 50%. 6

< 1 =

B Min. Spacing Center/Center A As Required Embedment

4 Reduced minimum free edge distance spacing of 13 of minimum free edge distance C is permissible when shear reinforcement is supplied per ACI-318-95 Section 1 Shear-Friction. 1.7

C Min. Free Edge Distance

ANCHOR SIZE
Pullout Safe Working Load (lbs.) (1) Shear Safe Working Load (lbs.) (1) (2) As Required Embedment (A) (6)

1 17,271 6,897 12 24 16 12 5

118 21,746 8,693 15 27 18 1312 6

114 27,617 11,036 15 30 20 15 612

138 32,918 13,151 18 33 2112 1612 7

112 40,043 16,001 18 37 24 18 8

134 54,122 21,635 24 43 2712 21 9

2 71,193 28,450 24 49 31 24 1012

2 14 92,568 36,986 30 56 35 27 1112

2 12

2 34

4,047 1,616 9 11 8 6 3

6,441 2,576 9 14 10 712 312

9,519 3,808 9 17 12 9 4

13,167 5,259 12 21 14 1012 4 12

113,972 140,619 170,060 45,533 30 62 39 30 13 56,182 36 69 43 33 14 67,949 42 76 48 36 15

Minimum Spacing Center/Center (B) (6) Minimum Free Edge Distance (C) (6)

Minimum Spacing Center/Center w/Reduced Safe Working Load (3) Min. Free Edge Distance w/Shear Reinforcement Per ACI-318 (4)

DECO: THE INDUSTRY STA N DA R D


For more than 50 years, Deco Manufacturing has delivered industrial products that stand the test of time. Our work is rock solid and so is our reputation. When it comes to your manufacturing needs, trust Deco Manufacturing to get the job done.

Call right now and well give you an estimate or place your order in minutes.

Page 2

Das könnte Ihnen auch gefallen