Sie sind auf Seite 1von 44

24.

Nurse Call System clino opt 99

clino systems programme

clino phon
Nurse Call System with Two-Way Speech Facility

clino opt
Nurse Call System with Audio-Visual Signalling

clino call
Paging System

clino soft
Software Solutions for the Nursing Staff

clino com
Accounting System for TV and Telephone

clino serv
Maintenance and Service Package

Nurse Call System clino opt 99

Albert Ackermann GmbH + Co. KG D-51641 Gummersbach Tel. (02261) 83-0 Fax 83-539 www.ackermann.com A member of Novar plc

DIN EN ISO 9001 Zertifikat: 09 100 4086

GEPRFTES UMWELTMANAGEMENT REG. NR. D-142-00004

clino opt is a registered trademark of Albert Ackermann GmbH + Co. KG

System overview clino opt 99

Databus terminator and splitter

Call cancel push button to further call push buttons Call push button (bed 1) Electronic module without bed databus Call push button (bathroom/WC)
A ERMANN ACK

Call push button (bed 2)

..........

.. 01....1 ....

. A 00.........
Bed databus

Pull cord (bathroom/WC)

Information display

to further call modules

Display module Electronic module with bed databus

Call module (bed 1)

Call module (bed 2)

Corridor databus

Call push button (bathroom / WC)

Pull cord (bathroom/WC)

Display module Electronic module for duty room


Remind

Service selection module

Duty room unit

Power supply

Power supply

Zone controller (group 1-3) Zone databus

Zone controller (group 4-6) to further zone controllers

Symbols Key / Table of Contents


page

System overview clino opt 99 Symbols key / table of contents System description clino opt 99 Zone controller Configuration module Interface unit Paging interface unit Printer interface PC interface Power supply Cover and mounting kit UPS module 24 V UPS module 230 V Electronic module for patient room Electronic module for duty room Direction lamps Information Display Ceiling mounting set Zone indicator lamp Corridor lamp Databus terminator and splitter Display module Speech module Call module Call module with push button and socket Patient handset Wall interface electronic Headphones Call push button Call push button for doctor call Call push button with socket Call push button with sockets Pull cord Pneumatic call push button Call unit with diagnostic sockets Pear push button, multiple push button Auto-release plug system Noise level sensor Pneumatic pear push button Call/cancel push button Cancel push button Cancel push button Touch-sensitive push button Backbox for touch-sensitive push button Master station Databus connection unit Duty selection module Duty room unit Display module, speech module Mounting frames for cover plates Standard plate Radio unit Programme selection switch Flush mounting backbox Cavity wall backbox Surface mounting socket Additional fastening for top-hat rail mounting Light bulb Part numbers

2 3 4 8 8 8 9 9 9 10 10 11 12 14 15 15 16 16 17 18 18 20 20 20 21 22 23 23 24 24 24 25 25 25 26 27 28 28 28 29 29 30 30 30 32 33 33 33 34 36 36 37 37 38 38 38 39 39 41

Zone controller

Components for power supply

Electronic module

Direction lamps Information display

Display module Call modules


27
PROG

TV R

LICHT

Patient handset

Call push button and call units Pluggable call units

Cancel push button

ACKERMANN clino opt 99


CALL HNO 312 A BATH/WC STA. BATH CALL HNO 355 B AW 1 DUTY

DUTY

Master station Duty selection module

Cover plate

Backboxes with accessories

System description clino opt 99

Nurse call system clino opt 99


General
Ackermanns nurse call system clino opt 99 conforms to the currently valid standards and conditions for call systems, DIN VDE 0834 part 1 and 2 : 2000-04 clino opt 99 is ideally suited to hospitals, nursing homes, residences for handicapped persons, rehabilitation clinics or sanatoria.

System overview
The nurse call system clino opt 99 combines intelligent network users with interactive data communication. The system is able to handle up to 16 zone controllers, each of which can be subdivided into 3 zones. Up to 127 patient rooms (electronic modules) can be controlled via the corridor databus of the zone controller. It should be noted that other direct users, such as interface units or electronic modules with direction lamps, are treated like patient rooms. Up to 255 active units, such as electronic modules, display modules or call modules can be used for each zone. Each active unit represents a network user for the system and can be identified by means of an 8-digit alpha-numeric text.

System characteristics
A distinguishing feature of the system clino opt 99 is its quick and easy installation. It is based on modular technology. The electronic modules can be replaced without entering the patients room. Calls and presences can be displayed in any room, e.g. in the duty and patients room and can also be answered from there with the appropriate equipment. Additionally, a nurse call guide system can be installed by using direction lamps. The system is equipped with two presence circuits. By activating a presence push button the call from the room concerned is cancelled, the call transfer is activated and the emergency call prepared. Calls from other rooms can then be audibly indicated in this room and displayed by using a display module. Calls from other zones can be displayed by means of zone indicator lamps and display modules. Any zone linking occurs by means of an additional duty selection module.

System structure
clino opt 99 system is an integrated system based on a controller unit, electronic modules and room equipment. The wiring consists of the corridor databus and the room databus (ZB-A, ZB-B), whereby the room databus is a twisted pair. A 6-core cable is required for supplying power, the speech and data lines, where as 4-core cable is sufficient for systems without a two-way speech facility. A suitable cable must be used, taking into account the provision of power in conjunction with the length of the cable as well as the number of modules connected. The electronic modules which are mounted outside the rooms also serve as distribution points for the room wiring and as sockets for the printed circuit boards. The power is supplied by a 24V/DC power supply.

System description clino opt 99 Zone controller


The zone controller is the central control unit which monitors and synchronizes the complete databus and at the same time represents a higher-level connection to further zone controllers. It controls the flashing phases of the room and zone signal lamps, as well as the acoustic call signals. In this way doctor, emergency, normal, remind and telephone calls can be distinguished. Each zone controller supports 3 sub-groups and thus has appropriate outputs for zone indicator lamps, telephone lamps as well as a common malfunction message system. Further inputs allow staff, dinner and telephone calls to be coupled.

Electronic module
The electronics required for call identification as well as the logging of calls are to be found in the electronic module, which is used as the distribution point for the room wiring. Electronic modules with integrated corridor lamp can be used for the whole system. Configuration data is stored in the electronic modules memory module and is, thereby, still available if the electronic module is replaced. For duty rooms, special electronic modules with additional memory for configured zone linking data are used.

Room equipment
Various devices can be installed in the rooms, for example, call modules, call push buttons, pear push buttons and pull cords for making calls, as well as cancel push buttons for cancelling calls. Patient handsets are also an option. In addition to their call function, these also enable patients to listen to radio. The information in the nurse call system can be shown on display modules. Calls are indicated according to their urgency. If there are no calls in the system, then presences are indicated. Use of additional speech modules enables queued calls to be addressed. Calls which have been addressed can be cancelled by remote control. Emergency calls cannot be cancelled by remote control. In the corridors, calls are visually indicated as text on the information displays and optically indicated by the corridor lamps. The following call types are shown. Type of call As per DIN VDE 0834-1 : 2000-04 nurse call (abbr: call) WC call (no information) emergency call alarm call (no information) Visual signals

Patient calls: normal call bathroom/WC call Priority call Staff calls: emergency call doctor call bathroom/WC emergency call Further calls: diagnostic call remind call telephone call fault

permanent light red permanent light red (optional: and permanent light - white -) flashing light - red flashing light red permanent light green and/or yellow quickly flashing light red , permanent light green and/or yellow flashing light red (optional: and flashing light white -), permanent light green and/or yellow flashing light red flashing light green permanent light telephone lamp white permanent light - red 5

diagnostic call (no information) telephone call fault

System description clino opt 99


Calls to the zone signal lamps or equipment with information displays (when connected) are recognisable throughout the zones. In addition to the visual signals, acoustic signals are also sent to all rooms in which presences are set. The nurse call system divides the calls into three categories: category 1 comprises of normal and bathroom/WC calls; category 2 consists of emergency, diagnostic and priority calls, as well as bathroom/WC emergency calls; alarm calls, e.g. doctor calls, belong to category 3. Acoustically-transmitted calls are identified by means of different call rhythms.

Coupling
The clino opt 99 Nurse Call System can be connected to the clino call paging system via the paging interface unit. This transfers existing calls on the nurse call system to the pocket pager of staff via the paging system, indicating type of call, room number and possibly bed identification. Additionally, internal signals, such as fire alarms or technical alarms, can be connected via interface units. It is possible to connect the system to an Instabus EIB (European InstaBus).

Safety
In the case of power failure, calls are stored for approximately 24 hours. As soon as the power is switched on again, presences and calls which were set prior to power failure are indicated. In the case of failure of the zone controller, the system operates in an emergency mode, which involves the functions normal and emergency calls, cancellation, presence indication and call transfer to rooms where presence has been set, as well as the visual indication of the corridor lamps. The zone controller monitors all active units and displays any malfunctions as a collective message or as individual messages on the information display. The lamp outputs of the electronic modules are short-circuit protected. All electronic modules are fitted with a self-healing fuse. This not only protects the electronic modules but also the equipment in the room. An auto-release plug mounted on the pear or multiple push button as well as on the patient handset prevents damage to the cord. The electrical safety and EMV requirements of all the system components are in accordance with the CE directives. The IP protection classes indicated in the catalogue refer to the completely assembled appliance including cover plate and mounting frames.

Maintenance and service


The configuration module is connected via a service socket to the electronic module. This is used to address rooms and, where appropiate, individual beds. In addition, the configuration module can also be used for service purposes. A zone controller can be exchanged without any problem. It gains access to the data stored in the active units and configures itself. Only particular special parameters have to be entered again. The electronic modules can be exchanged at any time without interrupting the operation of the system and, by standard installations, can be installed or exchanged within the entire system.

Central devices Zone controller


for operating up to 127 rooms with a maximum of three subgroups. The zone controller monitors and controls the data communication within the zone and provides for data transfer between zone controllers. In the case of a power failure, calls and presences are stored for 24 hours. Dimensions: Installation: Colour: Protection: H = 182 mm, W = 110 mm, D = 34 mm surface mounting or top-hat rail mounting white RAL 9016 IP 40
TOP OBEN

Order No.

Zone controller without audio appropriate connection board Zone controller with audio appropriate connection board Additional equipment: fastening for top-hat rail mounting (page 39)

72640 72640 72640 72640

A2 Z1 B2 Z2

72640 Z1

88899 A

Configuration module
for easy and quick setting up of the room identification and system parameters. The values are picked off from the documents or from printed room number lists by means of a barcode reading device. The configuration module leads the user through the different menus via the 2x8 digit LC-Display. Dimensions: H = 345 mm, W = 235 mm, D = 55 mm Configuration module English other languages 72649 AA on request

Interface unit
for connection of the clino opt 99 system to an existing clino opt 90 nurse call system or other alarm systems equipped with dry contacts. Dimensions: Installation: Colour: Protection: H = 182 mm, W = 110 mm, D = 34 mm surface mounting or top-hat rail mounting white RAL 9016 IP 40 72641 A2 72641 Z1
72641 Z1

Interface unit appropriate connection board Additional equipment: fastening for top-hat rail mounting (page 39)

TOP

OBEN

88899 A
1 2

Central devices Paging interface unit


to connect the clino opt 99 system to a paging system. Data transmission can be carried out via either an RS 422 or an RS 232C (serial interface). Dimensions: Installation: Colour: Protection: H = 182 mm, W = 110 mm, D = 34 mm surface mounting or top-hat rail mounting white RAL 9016 IP 40 72643 C1 72643 Z1
72643 Z1

Order No.

Paging interface unit for connection to clino call HL appropriate connection board Connection to other paging systems Additional equipment: fastening for top-hat rail mounting (page 39)

TOP

OBEN

on request 88899 A

Printer interface
for connection of the clino opt 99 system to a printer. Data transmission can be carried out via either an RS 422 or an RS 232C (serial interface). Dimensions: Installation: Colour: Protection: H = 182 mm, B = 110 mm, D = 34 mm surface mounting or top-hat rail mounting white RAL 9016 IP 40 72643 I1 72643 Z1
72643 Z1

Printer interface for connection to a printer appropriate connection board Additional equipment: fastening for top-hat rail mounting (page 39)

TOP

OBEN

88899 A
1 2

PC interface
for connection of the clino opt 99 system to a PC for call logging. Data transmission can be carried out via either an RS 422 or an RS 232C (serial interface). Dimensions: Installation: Colour: Protection: H = 182 mm, W = 110 mm, D = 34 mm surface mounting or top-hat rail mounting white RAL 9016 IP 40 72643 H1 72643 Z1
72643 Z1

PC interface appropriate connection board Additional equipment: fastening for top-hat rail mounting (page 39)

TOP

OBEN

88899 A
1 2

Central devices Power supply


for a constant DC supply to nurse call systems. Compact design thanks to modern primary-clocked circuit technology according to EN 61000-3-2; suitable for top-hat rail assembly in the sub-distribution or also outside the sub-distribution by means of the mounting kit. The supply units are idling, overload and short-circuit proof. For uninterruptible power supply according to DIN 19240 at 24 V see UPS module. Temperature range and protection classes: Temperature range: 0 to +60 C, with free convection cooling Protection class: IP 20 Protective low voltage SELV (according to EN 60950, VDE 0100 part 410) PELV (according to VDE 0160) Protection Class 1 (IEC 536) Single-phase power supply 5A Nominal output voltage: 24 V DC +5% -1% Output current: 5A Input voltage: 85 - 132 VA / 176 - 264 VA 115/230 15% VAC reversible Dimensions: W = 65 mm, H = 125 mm, D = 103 mm Single-phase power supply 10A Nominal output voltage: adjustable 24 up to 28 V DC Output current: 10 A Input voltage: 85 - 132 VA / 176 - 264 VA 115/230 15% VAC reversible Dimensions: W = 122 mm, H = 125 mm, D = 103 mm Single-phase power supply 20A Nominal output voltage: adjustable 24 up to 28 V DC Output current: 20 A Input voltage: 85 - 132 VA / 176 - 264 VA 230 15% VAC Dimensions: W = 227 mm, H = 125 mm, D = 103 mm 89954 M1 Order No.

89954 R2

89954 R3

Protective cover and mounting kit


for wall mounting of power supplies outside a sub-distribution. Including top-hat rail. Colour: grey RAL 7035

Protective cover and mounting kit - for 5 A power supply - for 10 A power supply - for 20 A power supply 89954 MA 89954 MB 89954 MC

10

Central devices UPS module 24 V


for uninterruptible power supply according to DIN 19240, compatible with power supplies on Page 10, consisting of control electronics for top-hat rail assembly and separate modular, extendable battery pack for wall mounting. Nominal input voltage: 24 V DC Input voltage range: 22.5 ... 30 V DC Output voltage when battery-driven: typ. 26.5 ... 19.5 V DC Charging time for discharged batteries to 90%: approx. 14 hrs Battery voltage threshold Switching threshold for pre-warming of battery switch-off: typ. 21.5 V Switching threshold for total discharge protection: typ. 19.5 V Protection: IP20 Cooling: free air convection Allowable ambient temperature: 0 ... + 50 C Storage temperature: - 20 ... + 55 C UPS module weight: 2.5 kg UPS module fastening: terminal for top-hat rail assembly UPS module connection: screw terminals Battery connection: screw terminals UPS module 24 V 5.0 A DC Nominal output current Battery capacity: external battery 7 Ah Battery life (by 80% load @ 20 C): approx. 60 minutes Charging current: typ. 0.2 ... 0.5 A switchable in 5 increments Battery fuse internal: T 5 A (5 x 20 mm) Charging fuse internal: T 2 A (5 x 20 mm) UPS module dimensions W x H x D: 70 x 126 x 128.5 mm Battery weight: 5.6 kg Battery dimensions W x H x D: 180 x 159 x 110 mm Battery mounting (dimensions): wall mounting (235 x 131 mm) UPS module 24 V 10.0 A DC Nominal output current Battery capacity: external battery 15 Ah Battery life (by 70% load @ 20 C): approx. 60 minutes Charging current: typ. 0.5 ... 1 A switchable in 5 increments Battery fuse internal: T 10 A (5 x 20 mm) Charging fuse internal: T 4 A (5 x 20 mm) UPS module dimensions W x H x D: 70 x 141 x 151 mm Battery weight: 12.7 kg Battery dimensions W x H x D: 250 x 159 x 175 mm Battery mounting (dimensions): wall mounting (235 x 131 mm) UPS module 24 V 20.0 A DC Nominal output current Battery capacity: external battery 24 Ah Battery life (by 60% load @ 20 C): approx. 60 minutes Charging current: typ. 0.7 ... 2 A switchable in 5 increments Battery fuse internal: T 20 A (5 x 20 mm) FKH Charging fuse internal: T 4 A (5 x 20 mm) UPS module dimensions W x H x D: 86 x 220 x 160 mm Battery weight: 5.6 kg Battery dimensions W x H x D: 405 x 178 x 135 mm Battery mounting (dimensions): wall mounting (386 x 140 mm) Order No.

89954 C6

89954 C7

89954 C8

11

Central devices

UPS module 230 V


for uninterrupted power supply to the server and operating computer in clino systems. Technical data: Output power: 700 VA / 490 Watts Output voltage: 230 V AC 2 %; 50/60 Hz 0.1 % Output current: 3.0 A Supply time: by 100 % load - 10 minutes Input voltage: 230 V AC, 50/60 Hz Input current: 3.5 A Ambient conditions: - Temperature: 0 C - 40 C - Relative humidity: 0 - 95 % non-condensing Types: UPS module 230 V freestanding model Dimensions: W = 140 mm, H = 190 mm, D = 440 mm Weight: 12.5 kg UPS module 230 V 19- mounting Dimensions: 2 HU, D = 390 mm Weight: 16.4 kg

Order No.

7608903

76089 AC

12

Corridor Electronic module for patient rooms


The electronic module is the central control unit for the patient room; it is available with or without bed databus. In the case of electronic modules without bed databus, passive call push buttons are used. Electronic modules with bed databus enable the additional connection of active units. At the same time the electronic module is used as a corridor lamp. As active units, a display module, a speech module and up to eight call modules can be connected via the bed databus. The active units can be addressed with an eight-digit alpha-numeric text. Room identification and bed identification are defined during commissioning using the configuration module. All electronic modules are equipped with call and cancel circuits for passive circuits. Call circuits: doctor call diagnostic call bathroom/WC call patient call as normal call or as emergency call when presence is set. Cancel circuits: presence green , for the cancellation of all calls and presence 1; presence yellow , for the cancellation of all calls and presence 2; separate bathroom/WC cancellation for bathroom/WC calls in case of appropriate configuration Dimensions: Installation: Colour: Protection: W = 158 mm, D = 87 mm, H = 110 mm surface mounting white lamp cover IP 20 Order No.

Electronic module for patient rooms with corridor lamp (including lamps) without bed databus - without presence 2 - with presence 2 appropriate connection board, grey RAL 7040 appropriate connection board, white RAL 9016 Electronic module for patient rooms with corridor lamp (including lamps) with bed databus and audio - without presence 2 - with presence 2 appropriate connection board, grey RAL 7040 appropriate connection board, white RAL 9016 Electronic module for patient rooms with corridor lamp (including lamps) with bed databus and Radio, audio - without presence 2 - with presence 2 appropriate connection board, grey RAL 7040 appropriate connection board, white RAL 9016 Electronic module for patient rooms without corridor lamp, cover plate white Ral 9016: without bed databus, with presence 2 appropriate connection board, white RAL 9016 Electronic module for patient rooms without corridor lamp, cover plate white Ral 9016: with bed databus, audio and presence 2 appropriate connection board, white RAL 9016 Accessories: Protective hood for electronic module Name plate holder for electronic module 14

72570 C2 72570 D2 72570 Z1 72570 Z2

72571 C2 72571 D2 72571 Z1 72571 Z2

72572 C2 72572 D2 72572 Z1 72572 Z2

72570 A2 72570 Z2

72571 A2 72571 Z2 89870 E1 88886 A

Corridor Electronic module for duty rooms


with additional functions to the electronic module for the patient room. These include the acknowledgement of calls and the possibility of connection to a duty selection module. It is also possible to regulate the sound level of the buzzer, e.g. for night duty. It is used together with the duty room selection module to link zones. Dimensions: W = 158 mm, D = 87 mm, H = 110 mm Installation: surface mounting Colour: white lamp cover Protection: IP 20 Electronic module for duty rooms with corridor lamp (including lamps) with bed databus electronic module without presence 2 electronic module with presence 2 appropriate connection board, grey RAL 7040 appropriate connection board, white RAL 9016 Electronic module for duty rooms without corridor lamp, cover plate white Ral 9016 appropriate connection board, white RAL 9016 Order No.

72573 C2 72573 D2 72571 Z1 72571 Z2 72573 A2 72571 Z2

2-way direction lamp


indicates visually the highest priority calls from the selected section of a zone. The calls on the direction lamp are displayed with different call cycles: the normal call by a steady light and the emergency call by a flashing light. Dimensions: Installation: Colour: Protection: W =158 mm, D = 87 mm, H = 110 mm surface mounting white lamp cover IP 20 72574 C2 72574 Z1 72574 Z2

2-way direction lamp (including lamps) direction lamp right/left appropriate connection board, grey RAL 7040 appropriate connection board, white RAL 9016

Direction lamp with arrow


indicates visually the highest priority calls on the direction lamp from the selected section of a zone. The calls on the direction lamp are displayed with different call cycles: the normal call by a steady light and the emergency call by a flashing light. Dimensions: Installation: Colour: Protection: W = 158 mm, D = 87 mm, H = 110 mm surface mounting white lamp cover IP 20 72574 A2 72574 B2 72574 Z1 72574 Z2

Direction lamp with arrow (including lamps): direction lamp left direction lamp right appropriate connection board, grey RAL 7040 appropriate connection board, white RAL 9016

15

Corridor Information Display


with red LEDs for luminescent, alpha-numerical display, with clear text and integrated buzzer. Functions when connected to system: call indication according to configuration indication of call type: doctor call, diagnostic call, emergency call, bathroom/WC-emergency call, enhanced call, bathroom/WC call, normal call (nurse call) indication of the time in combination with clock module or PC audible call transfer via buzzer if configured Calls are displayed in the following order: The calls are displayed according to their priority (in the order: alarm call, emergency call, call). If more than one call of a particular type exists, these are displayed in rotation, the display changing every 5 seconds. Display: 8-digit LED-display Material: surface mounted aluminium housing, white RAL 9010 Dimensions: for wall mounting: L = 750 mm, H = 103 mm, D = 35 mm for ceiling mounting: L = 750 mm, H = 103 mm, D = 100 mm Information Display single for wall mounting double-sided for ceiling mounting 74652 A2 74653 A2 Order No.

Ceiling mounting set for information display


complete with cover and suspension kit for ceiling mounting of the double-sided information display unit. Quantity: Material: Colour: Dimensions: 2 pieces steel (varnished) white RAL 9010 = 13 mm 89603 B1 89603 B2

Ceiling mounting set L = 300 mm Ceiling mounting set L = 600 mm

16

Corridor Zone indicator lamp


same design as corridor lamp, with one lamp section for each lamp cover. Dimensions: W = 158 mm, D = 87 mm, H = 110 mm each lamp cover Installation: surface mounting Colour: plastic base grey RAL 7040, with white lamp cover Protection: IP 20 Zone indicator lamp (including lamps): 1 neutral 2 neutral 3 neutral 4 neutral lamp lamp lamp lamp cover covers covers covers 72515 72515 72515 72515 A1 B1 C1 D1 Order No.

Zone indicator lamp


same design as corridor lamp, with one lamp section for each lamp cover. Dimensions: W = 158 mm, D = 87 mm, H = 110 mm each lamp cover Installation: surface mounting Colour: plastic base grey RAL 7040, with white lamp cover Protection: IP 20 Zone indicator lamp (including lamps) 1 lamp 2 lamp 3 lamp 4 lamp cover with the number 1 covers with the numbers 1 and 2 covers with the numbers 1 to 3 covers with the numbers 1 to 4 72515 72515 72515 72515 A2 B2 C2 D2

Zone indicator lamp


same design as corridor lamp, with two lamp sections for each lamp cover. Dimensions: W = 158 mm, D = 87 mm, H = 110 mm each lamp cover Installation: surface mounting Colour: plastic base grey RAL 7040, with white lamp cover Protection: IP 20 Zone indicator lamp (including lamps) 1 2 3 4 lamp lamp lamp lamp cover with the numbers 1 and 2 covers with the numbers 1 to 4 covers with the numbers 1 to 6 covers with the numbers 1 to 8 72515 72515 72515 72515 A3 B3 C3 D3

17

Corridor Corridor lamp


parallel display for the electronic module. Dimensions: Installation: Colour: Protection: W = 158 mm, D = 87 mm, H = 110 mm surface mounting white lamp cover IP 20 72569 C 72569 Z1 72569 Z3 72569 D 72569 Z2 72569 Z4 Order No.

Corridor lamp (including lamps): with 3 lamp sections (white, red, green) appropriate connection board, grey RAL 7040 appropriate connection board, white RAL 9016 Corridor lamp (including lamps): with 4 lamp sections (white, red, green, yellow) appropriate connection board, grey RAL 7040 appropriate connection board, white RAL 9016

Corridor lamp
in LED technology to connect to an electronic module without lamp. Colour: Dimensions Installation: Protection: white RAL 9016 81 mm x 81 mm in flush box, DIN 49073 IP 40

Type (including cover plate and frame): Corridor lamp with LEDs red, green 72555 B1

Corridor lamp with LEDs red, white, green

72555 C1

Databus terminator and splitter


terminates the corridor databus with the appropriate impedance and enables branching and stub cable on the corridor databus. Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 72642 B 88910 A3

Databus terminator and splitter including connection terminals Additional equipment: suitable cover plate, white RAL 9016 suitable mounting frame (page 36)

18

Patients room Display module with call/cancel push button


for connection to the electronic modules with bed databus.for patient and duty room Includes integrated call and cancel push button. In case of set presence,existing calls are acoustically indicated and visually displayed. Equipped with: 2x8-digit alpha-numeric LCD with back light call push button cancel push button buzzer appropriate connection terminals Installation: Colour: Protection: in flush box, DIN 49073 white RAL 9016 IP 40 74910 C2 Order No.

Display module with call/cancel push button Additional equipment: suitable mounting frame (page 36)

Speech module
enables intercom within the clino opt 99 system. Connected to the electronic module with bed databus, the existing calls or presences which are displayed can be answered. A speech push button makes it possible to start and release a conversation and a dual speech push button controls the speech direction. Equipped with: microphone, loudspeaker, answering push button, push button for speech direction Dimensions: Installation: Colour: Protection: H = 140 mm, W = 69 mm, D = 25 mm surface mounting in combination with 2 flush boxes fastening with claws or screws white RAL 9016 IP 40 74912 A4 74912 Z1

Speech module Additional equipment: appropriate connection terminals suitable mounting frame (page 36)

Call module
for connection to the electronic module with bed databus. As an active unit the call module can be addressed with an 8-digit alpha numerical text as bed identification. Released calls can then be displayed by means of this bed identification. Equipped with: 1 LED orientation/reassurance lamp red appropriate connection terminals push button Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73071 F2 88881 K3

Call module with call push button Additional equipment: cover plate white RAL 9016 with 1 call push button red suitable mounting frame (page 36)

20

Patients room Call module with push button and socket


for connection to the electronic module with bed databus. As an active unit the call module can be identified with an 8-digit alpha numeric text as bed identification. Calls can then be displayed by means of this bed identification. Equipped with: 1 LED orientation/reassurance lamp red 1 7-pole socket with call-circuit monitoring appropriate connection terminals push button Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73071 E2 88881 L3 Order No.

Call module with push button and socket Additional equipment: cover plate white RAL 9016 with 1 push button red suitable mounting frame (page 36)

Call module with push button and sockets


for connection to the electronic module with bed databus. As an active unit the call module can be identified with an 8-digit alpha numeric text as bed identification. Released calls can then be displayed by means of this bed identification. Equipped with: 1 LED orientation/reassurance lamp red 1 7-pole socket with call-circuit monitoring 1 6-pole socket for diagnostic equipment with call-circuit monitoring appropiate connection terminals push button Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73071 D2 88881 J3

Call module with push button and sockets Additional equipment: cover plate white RAL 9016 suitable mounting frame (page 36)

21

Patients room Patient handset


Functions*: nurse call call release radio and TV on switch and selection of 8 radio programmes on switch and selection of TV programmes display of the selected programme on LED display push buttons for volume control others digital bi-directional data transmission via highly flexible connecting cable to the wall interface electronics plug-in system, auto-releasing depending on the mechanical load** automatic call release by pulling of the plug from the autorelease plug system on switch for reading light on switch for room light Equipped with: 1 loudspeaker, possibly receiver capsule 1 call push button with orientation light 1 LED reassurance light red 2 light push buttons 1 function selector (see below) 2 programme push buttons ( and ) 2 volume push buttons (+ and ) 1 3.5 mm jack socket for connection of headphones 2 m connection cable with auto-release plug Colour: Material: white RAL 9016 PC + ABS-FR Order No.

27
PROG

TV R

LICH T

Patient handset - with function selector radio/TV - with function selector radio/external connection Additional equipment: hook for patient handset

74130 A1 74130 B1 74131 A1

* The necessary connection to the nurse call system and the transmission of data, conversations and radio programmes occur via the wall interface electronics. ** In relation with wall interface electronic 73072 A2 or 73072 B2.

22

Patients room Wall interface electronic


for patient handset. Functions: selection of radio and TV channels transmission of data and radio programmes to and from the patient handset/electronic module Equipped with: 1 call push button with LED orientation/reassurance lamp red 1 7-pole socket for connection of a pear push button or multiple push button 1 6-pole socket for connection of diagnostic equipment 1 auto-release plug system for auto-release plug Colour: white RAL 9016 Material: PC + ABS-FR Dimensions of the surface housing: H = 182 mm, W = 110 mm, D = 33 mm Wall interface electronic for surface mounting for bedhead trunking unit 73072 A2 73072 B2 Order No.

Additional equipment: Housing base unit suitable for surface mounting of wall electronic type 73072 A2 for flush mounting for cavity wall mounting Frame for flush or cavity wall mounting Material: insulating material Colour: white RAL 9016

88950 A 88950 B 88956 B

Headphones
for patient handset and radio unit with volume control. Equipped with: 1 adjustable clip 2 ear protection sponges for headphones 3 m connection cable 1 jack plug (3.5 mm) Impedance: 32 Ohm Maximum capacity: 0.1 W Input: 0.05 W Transmission range: 40 Hz 15 kHz Weight: 61 g Headphones 89760 B

23

Patients room Call push button


for normally open and normally closed circuits. Equipped with: 1 LED orientation/reassurance lamp red 1 push button Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73022 A2 88881 G3 Order No.

Call push button Additional equipment: cover plate white RAL 9016 with 1 call push button red suitable mounting frame (page 36)

Call push button for doctor call


for normally open and normally closed circuits. Equipped with: 1 LED orientation/reassurance lamp red 1 push button Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73022 A2

Call push button for doctor call Additional equipment: cover plate white RAL 9016 with 1 doctor call push button blue suitable mounting frame (page 36)

88881 D3

Call push button with socket


for normally closed circuits. Equipped with: 1 LED orientation/reassurance lamp red 1 7-pole socket with call-circuit monitoring 1 push button Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73075 A 88881 L3

Call push button with socket Additional equipment: cover plate white RAL 9016 with 1 call push button red suitable mounting frame (page 36)

24

Patients room Call push button with sockets


for normally closed circuits. Equipped with: 1 LED orientation/reassurance lamp - red 1 7-pole socket with call-circuit monitoring 1 6-pole diagnostic socket with call-circuit monitoring 1 push button Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73075 B 88881 J3 Order No.

Call push button with sockets Additional equipment: cover plate white RAL 9016 with 1 push button - red suitable mounting frame (page 36)

Pull cord
for normally closed circuits with call-circuit monitoring. Equipped with: 2 m PVC cord with red handle 1 LED reassurance lamp red Dimensions: Installation: Protection: Pull cord Additional equipment: cover plate white RAL 9016 suitable mounting frame (page 36) 71 mm x 71 mm in flush box, DIN 49073 IP 54 70045 A3 88880 A3

Pneumatic call push button


for normally closed circuits with call-circuit monitoring. Equipped with: 2 m insulating plastic tube and rubber ball 1 reassurance lamp red Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 54 70006 B

Pneumatic call push button

Additional equipment: cover plate white RAL 9016 suitable mounting frame (page 36)

88880 C3

25

Patients room Call unit with diagnostic sockets


for normally closed circuits. Equipped with: 2 6-pole diagnostic sockets with call-circuit monitoring Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 Order No.

Call unit with diagnostic sockets Additional equipment: cover plate white RAL 9016 suitable mounting frame (page 36)

73075 C

88912 D3

26

Patients room Pear push button


for call-circuit monitoring, with 7-pole plug or auto-release plug, 2 m connection cable2 and drop wire for variable looping and strain relief. Equipped with: 1 call push button red with nursing staff symbol 1 LED reassurance lamp red Dimensions: Colour: W = 40 mm, L = 110 mm, D = 18 mm white RAL 9016 Order No.

Pear push button for call-circuit monitoring with: 7-pole plug auto-release plug1, 3 - auto-release plug A-coded4
1 In connection with wall electronic system or auto-release plug system, page 28. 2 Other lengths on request

74141 A1 74141 A3 74141 A4

Multiple push button


for call-circuit monitoring, with 7-pole plug or auto-release plug, 2 m connection cable2 and drop wire for variable looping and strain relief. Equipped with: 1 call push button red with nursing staff symbol 1 LED reassurance lamp red 1 light push button yellow Dimensions: Colour: W = 40 mm, L = 110 mm, D = 18 mm white RAL 9016

Multiple push button for call-circuit monitoring with: 1 light push button - yellow - 7-pole plug 1 light push button - yellow -auto-release plug, A-coded1, 4 2 light push buttons - yellow - 7-pole plug 2 light push buttons - yellow - auto-release plug, A-coded1, 4 74151 A1 74151 A4 74153 A1 74153 A4

1 In connection with wall electronic system or auto-release plug system, page 28. 2 Other lengths on request

27

Patients room Auto-release plug system - A-coded


for connection of pear push button or multiple push button with auto-release plug, suitable for flush mounting combination boxes and backboxes with 60 mm screw fixing centre. Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 74189 A Order No.

Auto-release plug system -A-coded

Additional equipment: cover plate white RAL 9016 suitable mounting frame (page 36)

88910 N3

Noise level sensor


for normally open and normally closed circuits with adjustable noise detection and time delay facility. Equipped with: 1 microphone 1 call push button red 1 push button for call interlock in order to test the noise wave 2 LED control lights 2 m connection cable with 7-pole diode plug Dimensions: Colour: 155 mm x 95 mm, D = 38 mm black RAL 9011 73300 B7

KE ST TE AC L F GE RU PE IT ZE ST TE F RU

RM AN N

Noise level sensor (English version)

Pneumatic pear push button


for call-circuit monitoring, with 7-pole connection plug. Colour: white Equipped with: 2 m insulating plastic tube with rubber ball and retaining clip Pneumatic pear push button 70007 A

28

Patients room Call/cancel push button


for normally open and normally closed circuits. Equipped with: 1 LED remind lamp green 1 buzzer for call transfer 1 LED orientation/reassurance lamp red Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73642 B2 Order No.

Call/cancel push button Additional equipment: cover plate white RAL 9016 with 1 call push button red , 1 cancel push button green suitable mounting frame (page 36)

88882 A3

Cancel push button, presence 1


for normally open and normally closed circuits. Equipped with: 1 LED remind lamp green 1 buzzer for call transfer Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73642 C 88881 H3

Cancel push button, presence 1 Additional equipment: cover plate white RAL 9016 with 1 cancel push button green suitable mounting frame (page 36)

Cancel push button, presence 2


for normally open and normally closed circuits. Equipped with: 1 LED remind lamp yellow 1 buzzer for call transfer Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73642 D 88881 M3

Cancel push button, presence 2 Additional equipment: cover plate white RAL 9016 with 1 cancel push button yellow suitable mounting frame (page 36)

29

Patients room Cancel push button


for normally open and normally closed circuits. Equipped with: 2 LED remind lamps green and yellow 1 buzzer for call transfer Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 73642 E Order No.

Cancel push button Additional equipment: cover plate white RAL 9016 with 2 cancel push buttons green and yellow suitable mounting frame (page 36)

88882 B3

Touch-sensitive push button


for normally open and normally closed circuits, with 4 mm VA cover plate, 70 mm. Touch-sensitive push button with call sensor and LED orientation/reassurance lamp - red -

71185 E2

Touch-sensitive push button with cancel sensor and LED remind lamp - green -

71185 D2

Backbox for touch-sensitive push button


for flush mounting of touch-sensitive call push button, with back and side entry. Equipped with: 1 metal spacer for plaster tolerance 1 dust cover 1 gasket 1 anchor plate Material: steel, galvanized and chromatized Backbox for touch-sensitive push button 89450 B

30

Duty room Master station


centralized display unit with optional speech facility. Dimensions: Colour: Material: Protection: L = 200 mm, W = 228 mm, H = 65 mm white RAL 9016 ABS, base anodized aluminium IP 20
ACKERMANN clino opt 99
CALL HNO 312 A BATH/WC STA. BATH CALL HNO 355 B AW 1 DUTY

Order No.

Structure: desktop unit with 2 m connection cable and 8-pole plug Functions: call and status identification with following indications: zone, patient room, bed, normal call (nurse call), bathroom/WC calls, emergency call, bathroom/WC emergency call, diagnostic call, doctor call, answered call in remind mode, presence 1, presence 2, malfunction, other calls, conversation, plug release call call activation doctor call activation (types "74420 B1" and "74421 B1") call reminder function and call cancellation (types "74421 A1" and "74421 B1") selection of zone linking call answering nurse-to-nurse communication nurse/patient two-way speech simultaneous display of several calls and presences general address call to all rooms and zones general address call to presence 1 and/or presence 2 function activation (e.g., call answering, zone linking) by just touching the display screen menu index and free allocation of function push buttons ( e.g., day/night switching) Equipped with: 1 loudspeaker 1 microphone 1 call push button red with LED reassurance lamp 1 doctor call push button blue with LED reassurance lamp (types "74420 B1" and "74421 B1") 2 presence push buttons green and yellow with LED remind lamps 1 push button answer/off white with speech indication lamp 1 push button for speech direction brown 1 buzzer for call transfer 1 lit graphic LC display with touch-sensitive surface (touch screen) Master station Desktop unit without speech facility: without doctor call push button with doctor call push button Desktop unit with speech facility: without doctor call push button with doctor call push button

DUTY

74420 A1 74420 B1 74421 A1 74421 B1

32

Duty room Databus connection unit


for connecting master station to electronic module duty room. Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40 Order No.

Equipped with: 1 8-pole data plug databus connection unit Additional equipment: cover plate white RAL 9016 suitable mounting frame (page 36) 73070 A 88911 J3

Duty selection module


for connection to electronic module for duty room. With integrated push button for selection and activation of zone linking. Installation: Colour: Protection: in flush box, DIN 49073 white RAL 9016 IP 40

Equipped with: 2 white push buttons suitable connection terminal Duty selection module Additional equipment: suitable mounting frame (page 36) 74911 B3

Duty room unit


for connection to electronic module for duty room with acknowledgement option for queued calls. Dimensions: Installation: Colour: Protection: 71 mm x 71 mm in flush box, DIN 49073 white RAL 9016 IP 40

Equipped with: 2 LED remind lamp green and red 1 buzzer for call transfer Duty room unit Additional equipment: cover plate white RAL 9016 with 1 presence push button green and 1 acknowledge push button white (English version) suitable mounting frame (page 36) 73642 B 88882 CA

33

Duty room Display module with call/cancel push button


for connection to the electronic modules with bed databus for patient and duty room. Includes integrated call and cancel push button. In the case of set presence, existing calls are acoustically indicated and are shown on the display. Installation: Colour: Protection: in flush box, DIN 49073 white RAL 9016 IP 40 Order No.

Equipped with: 2x8-digit alpha-numeric LCD with back light call push button cancel push button buzzer appropriate connection terminals 1 LED remind lamp - green 1 LED orientation/reassurance lamp - red Display module with call/cancel push button Additional equipment: suitable mounting frame (page 36) 74910 C2

Speech module
enables intercom within the clino opt 99 system. Connected to the electronic module with bed databus, the existing calls or presences which are displayed can be answered. A speech push button makes it possible to start and release a conversation and a dual speech push button controls the speech direction. Dimensions: Installation: Colour: Protection: 140 mm x 69 mm, D = 25 mm surface mounting in combination with 2 flush boxes claw or screw fastening. white RAL 9016 IP 40

Equipped with: microphone, loudspeaker, answering push button, push button for speech direction Speech modul Additional equipment: appropriate connection terminals suitable mounting frame (page 36) 74912 A4 74912 Z1

34

Additional equipment Mounting frames for cover plates


clino opt 99 design. Colour: white RAL 9016 Mounting frames for cover plates - Single (Dimensions: 81 mm x 81 mm) - Double (Dimensions: 81 mm x 152 mm) - Triple (Dimensions: 81 mm x 223 mm) 88914 A3 88914 B3 88914 C3 Order No.

Standard plate
as per DIN 49075, suitable for all frame types (see above). Colour: white RAL 9016 Standard plate 88910 B3

36

Additional equipment Radio unit


with volume control and connection to dynamic headphones (page 23). Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 20 Order No.

Equipped with: 1 volume control 1 jack plug socket for the connection of dynamic headphones Radio unit Additional equipment: cover plate white RAL 9016 suitable mounting frame (page 36) 73120 H

88912 K3

Programme selection switch


with mounting plate and expanding retaining clamps suitable for flush mounting in backboxes. Dimensions: Installation: Protection: 71 mm x 71 mm in flush box, DIN 49073 IP 40

Equipped with: 1 programme selection switch for 5 radio programmes Programme selection switch Additional equipment: cover plate white RAL 9016 suitable mounting frame (page 36) 73120 A

88912 H3

37

Additional equipment Flush mounting backbox


as per DIN 49073, for expanding retaining clamps and screw fastening. Dimensions: = 58 mm, D = 40 mm Flush mounting backbox 18971 A Order No.

Cavity wall backbox


for wood, plaster and other cavity walls. Dimensions: = 71 mm, D = 65 mm Material: thermoplastic, flame-retardant Fixing centre: 60 mm Cavity wall backbox 18971 B

Surface mounting socket


Dimensions: Colour: 81 mm x 81 mm, D = 20.2 mm white RAL 9016 88915 A3

Surface mounting socket for flush mounting units, stackable.

Dimensions: Colour:

85 mm x 156 mm, D = 20.1 mm white RAL 9016 88915 C3

Surface mounting socket for the speech module 74912 A4.

38

Additional equipment Additional fastening for top-hat rail mounting


for: Zone controller Paging interface unit for connection to the paging system Interface unit Additional fastening for top-hat rail mounting 88899 A Order No.

Light bulb
for electronic modules, zone indicator lamps and direction lamps. 24 V / 3.5 W Light bulb - clear - red - green - yellow

88894 88894 88894 88894

A B C D

39

40

Part Numbers
Order No. 18971 A 18971 B 70006 B 70007 A 70045 A3 71185 D2 71185 E2 72515 A1 72515 A2 72515 A3 72515 B1 72515 B2 72515 B3 72515 C1 72515 C2 72515 C3 72515 D1 72515 D2 72515 D3 72555 B1 72555 C1 72569 C 72569 D 72569 Z1 72569 Z2 72569 Z3 72569 Z4 72570 A2 72570 C2 72570 D2 72570 Z1 72570 Z2 72571 A2 72571 C2 72571 D2 72571 Z1 72571 Z2 72572 C2 72572 D2 72572 Z1 72572 Z2 72573 A2 72573 C2 72573 D2 72574 A2 72574 B2 72574 C2 72574 Z1 72574 Z2 72640 A2 Page 38 38 25 28 25 72642 B 30 30 17 17 17 17 17 17 17 17 17 17 17 17 18 18 18 18 18 18 18 18 14 14 14 14 14 14 14 14 14, 15 14, 15 14 14 14 14 15 15 15 15 15 15 15 15 8 72643 C1 72643 H1 72643 I1 72643 Z1 72649 AA 73022 A2 73070 A 73071 D2 73071 E2 73071 F2 73072 A2 73072 B2 73075 A 73075 B 73075 C 73120 A 73120 H 73300 B7 73642 B 73642 B2 73642 C 73642 D 73642 E 74130 A1 74130 B1 74131 A1 74141 A1 74141 A3 74141 A4 74151 A1 74151 A4 74153 A1 74153 A4 74189 A 74420 A1 74420 B1 74421 A1 18 74911 B3 9 9 9 9 8 7608903 24 33 21 21 20 23 23 24 25 26 37 37 28 33 29 29 29 30 22 22 22 27 27 27 27 27 27 27 28 32 32 32 88950 A 88950 B 88956 B 23 23 23 41 88880 A3 88880 C3 88881 D3 88881 G3 88881 H3 88881 J3 88881 K3 88881 L3 88881 M3 88882 A3 88882 B3 88882 CA 88886 A 88894 A 88894 B 88894 C 88894 D 88899 A 88910 A3 88910 B3 88910 N3 88911 J3 88912 D3 88912 H3 88912 K3 88914 A3 88914 B3 88914 C3 88915 A3 88915 C3 25 25 24 24 29 21, 25 20 21, 24 29 29 30 33 14 39 39 39 39 8, 9, 39 18 36 28 33 26 37 37 36 36 36 38 38 12 74912 A4 74912 Z1 76089 AC 33 20, 34 20, 34 12 89954 C6 89954 C7 89954 C8 89954 M1 89954 MA 89954 MB 89954 MC 89954 R2 89954 R3 11 11 11 10 10 10 10 10 10 Order No. 72640 B2 72640 Z1 72640 Z2 72641 A2 72641 Z1 Page 8 8 8 8 8 Order No. 74421 B1 74652 A2 74653 A2 74910 C2 Page 32 16 16 89760 B 20, 34 89870 E1 14 23 Order No. 89450 B 89603 B1 89603 B2 Page 30 16 16

Albert Ackermann GmbH + Co. KG D-51641 Gummersbach Telefon (0 22 61) 830 . Fax (0 22 61) 8 35 39 www.ackermann.com A member of Novar plc

24.1 GB / 0503 / 2000 / aD

Ackermann, Gummersbach 2003

Printed on environmentally friendly paper using chlorine free pulps.

Das könnte Ihnen auch gefallen