501 Insulation Tester

The model 501 can be used for general purpose insulation tests that require voltages from 50V to 1000V only. The Instrument is equipped with AC and DC measuring ranges up to 1000V. This is advantageous for testing for the absence of voltage and the discharge of capacitive devices under test. The 501 features a quick testing signal lamp within the test probe that illuminates the work area. The signal lamp can also be used for quick Pass/Fail evaluations of insulation resistances. Minimum values for insulation resistances are present if the lamp lights up. Comes equipped with built-in test probes, an alligator clip, a leatherette carrying case and batteries. Five Test Voltages: 50, 100, 250, 500, and 1000 VDC Voltage Measurement to 1000 V AC/DC Test Probe Signal Lamp Illuminates Work Area and Indicates Pass/Fail of Insulation Resistance Battery Powered with Battery Test and Battery Charge Indicator Rugged Tester Design for Industrial Applications with Leatherette Carrying Case

Specifications
REFERENCE CONDITIONS Ambient Temperature: 73 F (23 C) 4 F (2 C) Relative Humidity: 45 to 55% Measurement Magnitude Frequency: 45-65 Hz (voltage measurements) Line Voltage Waveform: Sine, deviation between effective and rectified value < .5% Battery Voltage: 9V .5V Operating Position: Horizontal ELECTROMAGNETIC COMPATIBILITY EMC Interference Emission: EN 50081-1: 1992 Interference Immunity: EN 50082-1: 1992 ELECTRICAL SAFETY Designed to IEC 1010-1 Protection Class: II Test Voltage: 5.55Kv Overvoltage Classification: II Pollution Degree: 2 Protection: Housing IP52 AMBIENT CONDITIONS Operating Temp. Range: 32 F (0 C) to 104 F (40 C) Storage Temp. Range: -4 F (-20 C) to 140 F (60 C) (without batteries) Relative Humidity: Max. 45-55%, condensation must be avoided MECHANICAL DESIGN Dimensions: W 6.50 (165mm) x D 4.33 (110mm) x H 4.92 (125mm) Weight: 3.5 lbs. (1.6kg) (with batteries) POWER SUPPLY Standard or Storage Battery: 6 ea. 1.5V D size batteries Working Range: 7V to 10V Battery Service Life: Number of possible measurements with 1 set of D size batteries (with lamp in test prod switched off): at least 3,000 measurements of an insulation resistance of 1M (Nominal Voltage of1000 V, 5 sec. Measurement duration, switched off for 25 sec. etc.)
rev_1 11/2/04

Measuring Ranges
INSULATION RESISTANCE
Measuring Range 050K 20K 1M 200K 20M 0100K 40K 2M 400K 40M 0250K 100K 5M 1M 100M 0500K 200K 10M 2M 200M 01M 400K 20M 4M 400K 04K Lamp in Test Prod 1) Open-Circuit Voltage Uo Internal Resistance R i Lights for Resistance 60V 30K 10K 40K 60K 20K 80K 150K 50K 200K 300K 100K 400K 600K 200K 800K > 100K

> 200K

120V

> 500K

300V

> 1M

600V

> 2M

1200V 9V

(1) Switching Accuracy

DIRECT AND ALTERNATING CURRENT


Measuring Range 0 to 1000V AC/DC Frequency 0 or 40 to 200Hz Internal Resistance 900K Maximam Overload 1200V AC/DC Continuous Intrinsic Error (1) 2.5%
(1) Referring to scale length

Ordering Information
ACCESSORIES 501 Insulation Tester, 1000 V Catalog No. 12501