POWR-GARD Fuse Datasheet

Class RK5 IDSR Series indicator fuses


600 V AC/DC Dual Element Time-Delay 1/10 -600 A


Ordering Information
/
1/8
15/100
2/10
1/4
3/10
4/10
1/2

/
8/10
1
1 1/8
1 1/4
1 4/10
1 1/2
1 6/10

1 8/10
2
2 1/4
2 1/2
2 8/10
3
3 2/10
3 1/2

6 10

1 10

Ampere ratings
4
8
4 1/2
9
5
10
5 6/10
12
6
15
6 1/4
17 1/2
7
20
7 1/2
25

30
35
40
45
50
60
70
75

80
90
100
110
125
150
175
200

225
250
300
350
400
450
500
600

Note: All fuses rated 1A and above are Indicator fuses.

series

amperage

IDSR

30

Catalog Number Ordering Number


IDSR030

IDSR030.T

Web Resources
TC Curves, downloadable CAD drawings and other technical
information: www.littelfuse.com/idsr

Description
The IDSR combines a 600 VDC capability with indication to
provide an ideal solution for many DC applications.

Recommended Fuse Holders


LFR60 Series

Applications

Dimensions

DC circuits

Please refer to the Class R dimensions

Solar inverters
Motors

Peak Let-Thru Curve

Transformers
Solenoids

IDSR

Fluorescent lighting

1000000

Features/Benefits
POWR-PRO Performance
Indication

100000

PEAK LET-THRU IN AMPERES

Specifications
Voltage Ratings AC: 600 V
DC: 600 V
Interrupting Ratings AC: 2 00 kA rms symmetrical
300 kA rms symmetrical
(Littelfuse self-certified)

DC: 20 kA
1 /10 600 A
Ampere Range
Approvals Standard 248-12 and UL 198M, Class RK5
UL Listed (File: E81895)
CSA Certified (File: LR29862)

600 A
400 A
200 A
100 A
60 A

10000

30 A
15 A

1000

2000000

AVAILABLE FAULT CURRENT


SYMMETRICAL R.M.S. AMPERES

100000

10000

1000

100

100

Note: For more information, see Peak Let-Thru Table

www.littelfuse.com

1 of 2

2012 Littelfuse POWR-GARD Products

Rev: 100112

POWR-GARD Fuse Datasheet

Class RK5 IDSR Series indicator fuses


Current-Limiting Effects of IDSR (600 V) Fuses
Apparent RMS Symmetrical Current for Various Fuse Ratings

Short Circuit
Current*

15 A
800
1,100
1,300
1,400
1,500
1,600
1,700
1,800
1,900
2,000
2,200
2,300
2,600
2,800

5,000
10,000
15,000
20,000
25,000
30,000
35,000
40,000
50,000
60,000
80,000
100,000
150,000
200,000

30 A
1,100
1,600
1,900
2,200
2,500
2,700
2,900
3,100
3,400
3,600
4,000
4,200
4,500
4,600

60 A
2,100
2,900
3,400
3,800
4,100
4,500
4,700
5,000
5,400
5,800
6,300
6,800
7,700
8,400

100 A
3,200
4,300
5,000
5,600
6,100
6,500
6,800
7,200
7,800
8,300
9,100
9,800
11,200
12,400

200 A
5,000
7,300
8,600
9,500
10,300
11,000
11,600
12,100
13,100
13,900
15,400
16,700
19,300
21,400

400 A
5,000
10,000
13,700
15,500
16,700
17,700
18,600
19,400
20,800
22,000
24,000
25,500
28,100
30,000

600 A
5,000
10,000
15,000
19,000
21,500
23,500
25,200
26,600
29,500
30,600
33,200
35,100
38,000
39,600

*Prospective RMS Symmetrical Amperes Short-Circuit Current


Note: Data Derived from Peak Let-Thru Curves

Dimensions
F
G

K
B

FIG. 1

70-600A

FIG. 2
DIMENSIONS INCHES (mm)

AMPS

FIGURE
NUMBER

SERIES

1 10

/ 30

IDSR

5 (127.0)

35 60

IDSR

70 100

110 200

4 (19.1)

8 (15.9)

13

16 (20.6)

32 (2.4)

51 2 (139.7)

1 (25.4)

8 (15.9)

11 16 (27.0)

32 (2.4)

IDSR

77 8 (200.0)

11 4 (31.8)

11 16 (27.0) 15 16 (33.3)

8 (3.2)

IDSR

9 5 8 (244.5) 13 4 (44.5) 115 32 (37.3) 127 32 (46.8)

225 400

IDSR

115 8 (295.3) 2 1 2 (63.5)

219 32 (65.9)

450 600

IDSR

13 3 8 (339.7)

213 32 (61.1) 3 3 32 (78.6)

www.littelfuse.com

3 (76.2)

2 (50.8)

2 of 2

8 (15.9)

8 (22.2)

16 (4.8)

4 (6.4)

4 (19.1)

4 (6.4)

32 (7.1)

16 (4.8)

11 8 (28.6)

16 (11.1)

32 (7.1)

11

4 (6.4)

15 8 (41.3)

8 (15.9)

13

32 (10.3)

15

4 (6.4)

2 (50.8)

4 (19.1)

17

32 (13.5)

11 8 (28.6)

2 (12.7)
16 (17.5)

16 (23.8)

2012 Littelfuse POWR-GARD Products

Rev: 100112

Das könnte Ihnen auch gefallen