Sie sind auf Seite 1von 88

Lowara

4OS-L4C
L6C-L6W
L8W-L10W-L12W
Series
4- 6- 8- 10- 12
Submersible Motors
60 Hz

Lowara

WEB 12-2009

Lowara
CONTENTS

4 submersible motors 4OS series .......................................................................................................

11

4 submersible motors L4C series ...................................................................................................

17

6 submersible motors L6C series ...................................................................................................

23

6 submersible motors L6W series ..................................................................................................

31

8 submersible motors L8W series ..................................................................................................

39

10 submersible motors L10W series .............................................................................................

45

12 submersible motors L12W series .............................................................................................

51

Accessories ......................................................................................................................................

67

Technical appendix ..........................................................................................................................

Lowara

Lowara
4
Submersible
motors

Submersible liquid-cooled motors.


The choice of component materials ensures optimum
operating performances, superior quality, reliability and
ease of installation.

4OS Series
60 Hz

SPECIFICA
TIONS
SPECIFICATIONS
Stainless stell outer sleeve.
Shaft extension and coupling
dimensions to NEMA standards.
Rewindable stator
stator..
Class F insulation
insulation.
Protection class: IP68
IP68.
Internal fluid according to
standards for oils in contact with
foodstuffs (F.D.A. - FOOD AND
DRUG ADMINISTRATION).
Compensating bellows for internal
liquid expansion.
Axial load supported by angular
bearings.
Mechanical seal protected by
sand guard.
Maximum immersion depth
depth:
150 m.
Maximum number of starts per
hour at regular intervals:
30 for direct start;
20 for impedance start.
Maximum supply voltage
variations allowed :
220V -6%; 230V +6%.
380V 10%.

Rewindable
stator
Liquid suitable for
use with foodstuffs
(complies with FDA)
High starting
torque
Power supply
cable with
extractable
connector

Maximum water temperature :


35C.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket of at least 0,08 m/s.
Water pH
pH: 48.
Axial thrust
thrust:
3000 N from 0,37 to 2,2 kW;
6500 N from 3 to 7,5 kW.
Extractable supply cable
fitted with watertight connector.
Versions
ersions:
- Single-phase:
0,37 to 2,2 kW 220-230 V, 60 Hz
- Three-phase:
0,37 to 7,5 kW 220-230 V, 60 Hz
0,37 to 7,5 kW 380 V, 60 Hz.
Horizontal operation up to 2,2 kW.
Inverter applications.

OPTIONAL FEA
TURES
FEATURES

Special voltages.

Lowara
4OS MOTOR SERIES
MOTOR CROS
S SECTION AND T
ABLE OF MA
TERIALS
CROSS
TABLE
MATERIALS
4OS 0,372,2 kW

4OS 37,5 kW

MOTORI SERIE 4OS: TABELLA DEI MATERIALI


REF.

PART

DESIGNATION

MATERIAL

N.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Head
Studs
Filling screw
Sand guard
Connector sleeve
Cable
Outer sleeve
Mechanical seal
Shaft end for P 2.2 kW
Shaft end for 3 P 7.5 kW
Elastomers
Lower bracket
Compensating diaphragm
Lower protection
Snap ring
Screws, nuts, washers
Upper cover
Cooling liquid

Cast iron
Stainless steel
Brass
NBR
Stainless steel
Epdm
Stainless steel
Carbon / Ceramic
Stainless steel
Stainless steel
NBR
Cast iron
NBR
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Non toxic oil

EUROPE

USA

UNI EN 5007 G20


EN 10088-3-X5CrNi18-10 (1.4301)
EN12165-CuZn40Pb2 (CW617N)

ASTM A159-70-G3500
AISI 304

EN 10088-1-X5CrNi18-10 (1.4301)

AISI 304

EN 10088-1-X5CrNi18-10 (1.4301)

AISI 304

EN 10088-3-X8CrNiS18-9 (1.4305)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)

AISI 303
ASTM A 182: F51

UNI EN 5007 G20

ASTM A159-70-G3500

EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-3-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)

AISI 304
AISI 304
AISI 304
AISI 304
4OS-2p50-en_b_tm

Lowara
4OS MOTOR SERIES
IDENTIFICA
TION CODE
IDENTIFICATION
4OS

11

23

/_

VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
M = SINGLE-PHASE
T = THREE-PHASE
RATED POWER IN kW x 10
4OS SERIES NAME
EXAMPLE : 4OS11M236/C
4OS MOTOR :
RATED POWER 1,1 kW; SINGLE-PHASE;
RATED VOLTAGE 230 V; 60 Hz; /C VERSION.

RA
TING PLA
TE
RATING
PLATE
SINGLE-PHASE

THREE-PHASE

LEGEND
1 - Motor type
2 - Code
3 - Maximum water temperature
4 - Minimum water velocity
5 - Insulation class
6 - Protection class

7 - Weight
8 - Maximum immersion depht
9 - Operating characteristics
10 - Capacitor type
11 - Service type
12 - Characteristics at service factor

Lowara
4OS MOTOR SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT

MOTORI SERIE 4OS: DIMENSIONI E PESI - 2 poli 60Hz


RATED POWER

MOTOR
TYPE

kW

4OS03M236-116
4OS03T236-386
4OS05M236-116
4OS05T236-386
4OS07M236-116
4OS07T236-386
4OS11M236-116
4OS11T236-386
4OS15M236
4OS15T236-386
4OS22M236
4OS22T236-386
4OS30T236-386
4OS22T236-386
4OS55T236-386
4OS75T236-386

Max DIMENSIONS mm

HP

0,37

0,5

0,55

0,75

0,75

1,1

1,5

1,5

2,2

3
4
5,5
7,5

4
5,5
7,5
10

WEIGHT

kg

355
334
355
355
380
355
415
380
450
415
500
450
450
570
630
836

7,3
6,8
7,9
7,3
9
7,9
10,9
9
12,5
11,1
14,8
12,6
13,6
17,5
21
28,5
4OS-2p60-en_a_td

4OSM OPERATING CHARACTERISTICS


- 60Hz
SINGLE-PHASE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

TYPE

POWER

VOLTAGE

CAPACITOR OPERATING CHARACTERISTICS

DIRECT ON-LINE

AT RATED POWER

STARTING

SERVICE SERVICE

MAX

CABLE TYPE

FACTOR FACTOR WATER


AMPS

TEMP.

NxA

SFA

mm2

SINGLEPHASE

kW

HP

4OS03M236 0,37 0,5


4OS05M236 0,55 0,75
4OS07M236 0,75

4OS11M236 1,1

1,5

4OS15M236 1,5

4OS22M236 2,2

4OS03M116 0,37 0,5


4OS05M116 0,55 0,75
4OS07M116 0,75

4OS11M116 1,1

1,5

220
230
220
230
220
230
220
230
220
230
220
230
110
115
110
115
110
115
110
115

20

450

25

450

35

450

40

450

50

450

50

450

80

250

100 250
140 250
160 250

rpm

cos

Is/In

Ts/Tn Tmax/Tn

3,40
3,45
4,66
4,73
5,87
6,09
7,61
7,48
10,1
10,1
15,2
15,7
6,81
6,91
9,68
10,2
11,5
11,9
20,1
14,5

3495
3500
3445
3460
3460
3470
3450
3460
3435
3445
3405
3420
3495
3500
3480
3490
3480
3490
3465
3475

49,7
47,4
54,3
52,2
59,8
56,9
66,2
64,4
67,8
66,1
70,5
68,2
49,8
47,5
53,4
49,9
60,7
57,8
69,1
67,3

0,99
0,98
0,99
0,97
0,97
0,94
0,99
0,99
0,99
0,97
0,93
0,90
0,99
0,98
0,98
0,94
0,98
0,95
0,99
0,98

4,00
4,13
3,26
3,36
3,85
3,88
3,64
3,87
3,90
4,08
3,14
3,18
4,00
4,22
3,63
3,54
4,05
4,06
4,05
4,46

1,23
1,35
0,84
0,92
0,74
0,82
0,79
0,87
0,63
0,70
0,50
0,55
1,23
1,36
0,63
0,67
0,56
0,59
0,46
0,49

Ts/Tn = ratio between starting torque and nominal torque.

2,98
3,26
2,26
2,47
2,47
2,72
2,27
2,49
2,26
2,49
1,79
1,97
2,97
3,32
2,72
2,98
2,94
3,02
2,37
2,57

SF

1,6
1,5
1,4
1,3
1,25
1,15
1,6
1,5
1,4
1,3

4,50
4,42
6,23
6,00
7,41
7,36
9,34
9,05
12,2
11,9
17,1
17,1
9,02
8,86
12,3
12,3
14,5
14,3
18,1
17,7

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5 1,75

2,5

4osm-2p60-en_b_te

Tmax/Tn = ratio between maximum torque and nominal torque.

Lowara
4OS
MOTOR SERIES
4OS OPERATING CHARACTERISTICS - 60Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT ON-LINE

SERVICE SERVICE

MAX

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

FACTOR FACTOR

WATER

CABLE TYPE

AMPS

TEMP.

NxA

SFA

mm

THREEPHASE

kW

HP

4OS03T236

0,37

0,5

4OS05T236

0,55 0,75

4OS07T236

0,75

4OS11T236

1,1

1,5

4OS15T236

1,5

4OS22T236

2,2

4OS30T236

40S40T236

5,5

40S55T236

5,5

7,5

4OS75T236

7,5

10

40S03T386
4OS05T386
4OS07T386
4OS11T386
4OS15T386
4OS22T386
4OS30T386
4OS40T386
4OS55T386
4OS75T386

0,37 0,5
0,55 0,75
0,75
1
1,1
1,5
1,5
2
2,2
3
3
4
4
5,5
5,5
7,5
7,5
10

rpm

cos

Is/In

220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
380
380
380
380
380
380
380
380
380
380

2,68
2,93
3,26
3,45
4,54
5,01
5,66
6,06
7,45
7,98
10,8
11,9
13,2
13,8
15,7
15,7
21,4
21,2
33,5
35,4
1,55
1,88
2,62
3,27
4,30
6,25
7,61
9,05
12,3
19,4

3485
3495
3430
3450
3450
3465
3425
3445
3430
3445
3425
3440
3455
3470
3435
3455
3415
3440
3460
3475
3485
3430
3450
3425
3430
3425
3455
3435
3415
3460

58,5
56,4
62,3
61,1
66,3
63,7
71,5
70,1
74,4
72,6
75,7
72,6
76,3
75,7
78,9
78,8
78,6
78,5
78,7
77,6
58,5
62,3
66,3
71,5
74,4
75,7
76,3
78,9
78,6
78,7

0,62
0,56
0,71
0,65
0,66
0,59
0,72
0,65
0,71
0,65
0,71
0,64
0,79
0,72
0,85
0,81
0,86
0,83
0,75
0,68
0,62
0,71
0,66
0,72
0,71
0,71
0,79
0,85
0,86
0,75

6,40
6,19
5,52
5,48
5,58
5,32
5,45
5,37
5,73
5,62
5,53
5,32
5,41
5,46
5,85
6,17
5,48
5,81
6,28
6,26
6,40
5,52
5,58
5,45
5,73
5,53
5,41
5,85
5,48
6,28

Ts/Tn = ratio between starting torque and nominal torque.

Ts/Tn Tmax/Tn

5,71
6,33
4,40
4,91
4,23
4,69
3,80
4,24
3,64
4,05
3,63
4,04
2,44
2,72
1,81
2,02
1,63
1,82
2,53
2,81
5,71
4,40
4,23
3,80
3,64
3,63
2,44
1,81
1,63
2,53

4,73
5,25
3,22
3,59
3,27
3,62
2,89
3,22
3,01
3,35
2,90
3,22
2,79
3,11
2,70
3,01
2,51
2,79
3,41
3,79
4,73
3,22
3,27
2,89
3,01
2,90
2,79
2,70
2,51
3,41

SF

1,6
1,5
1,4
1,3
1,25
1,15
1,15
1,15
1,15
1,15
1,6
1,5
1,4
1,3
1,25
1,15
1,15
1,15
1,15
1,15

3,17
3,31
4,00
4,05
5,21
5,51
6,53
6,70
8,40
8,73
11,6
12,5
14,5
14,8
17,7
17,4
24,4
23,8
36,8
38,1
1,83
2,31
3,01
3,77
4,85
6,69
8,35
10,2
14,1
21,2

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5 1,75

35

4x1.5

2,5

35

4x1,5

2,5

35

4x1.5

2,5

35

4x2.5

2,5

35

4x2.5

35
35
35
35
35
35
35
35
35
35

4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
4x1,5
4x1.5
4x1.5
4x1.5

1,75
1,75
1,75
1,75
1,75
2,5
2,5
2,5
2,5
4

4ost-2p60-en_b_te

Tmax/Tn = ratio between maximum torque and nominal torque.

Lowara

10

Lowara
4
Submersible
motors

Submersible canned motors.


The choice of component materials ensures optimum
operating performances, superior quality, reliability and
ease of installation.

L4C Series
60 Hz

SPECIFICA
TIONS
SPECIFICATIONS
Stainless steel outer sleeve.
Shaft extension and coupling
dimensions to NEMA standards.
Class F insulation
insulation.
Protection class: IP68
IP68.
Compensating bellows for internal
liquid expansion.
Axial load supported by Kingsbury
type thrust bearing.
Lip seal protected by sand guard.
Maximum immersion depth
depth:
300 m.
Maximum number of starts per
hour at regular intervals:
40 for direct start;
20 for impedance start.
Maximum supply voltage
variations allowed : 6%.
Maximum water temperature
temperature:
35C.
Max. temperrature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket of at least 0,3 m/s.

High starting
torque
Power supply
cable with
extractable
connector

11

Axial thrust
thrust:
2000 N from 0,37 to 1,1 kW;
3000 N from 1,5 to 2,2 kW;
6000 N from 3 to 7,5 kW.
Extractable supply cable
fitted with watertight connector.
Versions
ersions:
- Single-phase:
0,37 to 3,7 kW 220-230 V, 60 Hz
0,37 to 0,75 kW 110-115 V, 60 Hz
(0,37 to 0,75 kW with built in
automatic reset overload
protection).
- Three-phase:
0,37 to 5,5 kW 220-230 V, 60 Hz
0,37 to 7,5 kW 380 V, 60 Hz.
Can also operate in horizontal
position, provided that the
associated pump can apply an axial
thrust of at least 100 N on the entire
operating field.

OPTIONAL FEA
TURES
FEATURES

Special voltages.
Inverter applications.

Lowara
L4C MOTOR SERIES
MOTOR CROS
S SECTION AND T
ABLE OF MA
TERIALS
CROSS
TABLE
MATERIALS
L4C 0,372,2 kW

L4C 37,5 kW

TABELLA MATERIALI L4C


REF

PART

DESIGNATION

MATERIAL

1
2
3
4
5
6
7
8
9
10
11
12
13

EUROPE

Inner and outer sleeve


Flange
Shaft extension (up to 2.2 kW)
Shaft extension (from 3 kW)
Upper bracket
Upper cover
Lip seal
Elastomers
Lower cover
Compensating bellows
Bearings
Cable
Fixed sand guard
Removable sand guard
Bolts and screws
Cooling liquid

Stainless steel
EN 10088-1-X2CrNi18-9 (1.4307)
Carbon steel
EN 10025 - S355JR (Fe 510-B)
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Stainless steel
EN 10088-3 1.4460 X3CrNiMoN27
Cast iron
EN-GJL-200
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
NBR
NBR
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
EPDM
Carbon-graphite
EPDM
Nylon
NBR
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Demineralized water + antifreeze

USA

AISI 304L
ASTM A105
AISI 304
AISI 329
Class 25 B
AISI 304

AISI 304

AISI 304
l4c-2p50-en_e_tm

12

Lowara
L4C MOTOR SERIES
IDENTIFICA
TION CODE
IDENTIFICATION
L4C

11

23

/_

VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
M = SINGLE-PHASE
T = THREE-PHASE
RATED POWER IN kW x 10
L4C SERIES NAME
EXAMPLE : L4C11M236
L4C MOTOR :
RATED POWER 1,1 kW; SINGLE-PHASE;
RATED VOLTAGE 230 V; 60 Hz.

RA
TING PLA
TE
RATING
PLATE
SINGLE-PHASE

THREE-PHASE

LEGEND
1 - Motor type
2 - Code
3 - Maximum water temperature
4 - Minimum water velocity
5 - Insulation class
6 - Protection class
7 - Weight

8 - Maximum immersion depht


9 - Operating characteristics
10 - Production date
11 - Serial number
12 - Characteristics at service factor
13 - Service type
14 - Capacitor type

13

Lowara
L4C MOTOR SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT

DIMENSIONI E PESI MOTORI L4C - 2 poli 60Hz


MOTOR
TYPE

L4C03M236-116
L4C03T386
L4C05M236-116
L4C05T386
L4C07M236-116
L4C07T386
L4C11M236
L4C11T386
L4C15M236
L4C15T386
L4C22M236
L4C22T386
L4C30T386
L4C40M236
L4C40T386
L4C55T386
L4C75T386

RATED POWER
kW

DIMENSIONS mm

HP

0,37

0,5

0,55

0,75

0,75

1,1

1,5

1,5

2,2

3
4
4
5,5
7,5

4
5,5
5,5
7,5
10

WEIGHT

kg

266
236
286
266
331
286
391
346
411
391
451
411
544
684
614
684
764

8,6
7,9
9,6
8,7
11,7
9,8
13,9
11,7
15,2
13,9
17,8
14,8
21
27,5
23,7
26,8
30,2
l4c-2p60-en_c_td

L4CM OPERATING CHARACTERISTICS


- 60Hz
SINGLE-PHASE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

SERVICE

TYPE

POWER

FACTOR VOLTAGE

RATED

CAPACITOR OPERATING CHARACTERISTICS


AT FULL (S.F.) POWER

DIRECT

MAX

STARTING

WATER

CABLE TYPE

TEMPERATURE Nc x sec
SINGLE-PHASE

HP

S. F.

L4C03M236 0,37 0,5

1,6

L4C05M236 0,55 0,75

1,5

L4C07M236 0,75

1,4

L4C11M236 1,1

1,5

1,3

L4C15M236 1,5

1,25

L4C22M236 2,2

1,15

5,5

1,15

L4C03M116 0,37 0,5

1,6

L4C05M116 0,55 0,75

1,5

L4C07M116 0,75

1,4

L4C40M236

kW

220
230
220
230
220
230
220
230
220
230
220
230
220
230
110
115
110
115
110
115

20

450

25

450

35

450

40

450

50

450

50

450

75

450

80

450

100

450

140

450

rpm

5,3
5,5
7,0
7,4
8,5
8,9
12,2
12,7
13,1
12,8
17,6
17,1
30,7
29,7
10,6
11,0
14,0
14,8
17,0
17,8

3460
3480
3460
3485
3485
3500
3480
3485
3430
3455
3410
3420
3440
3460
3460
3480
3460
3485
3485
3500

55,0
52,0
60,0
57,0
59,0
57,0
61,0
58,0
65,0
65,0
68,0
67,0
74,0
74,0
55,0
52,0
60,0
57,0
59,0
57,0

* Ts/Tn = ratio between starting torque and nominal torque.

cos Ts/Tn*

Is/In

0,93
0,89
0,89
0,84
0,93
0,89
0,88
0,84
0,98
0,97
0,96
0,96
0,93
0,92
0,93
0,89
0,89
0,84
0,93
0,89

4,00
3,87
3,90
3,70
5,00
4,80
4,30
4,10
4,30
4,60
3,30
3,60
3,80
4,10
4,00
3,87
3,90
3,70
5,00
4,80

0,60
0,65
0,60
0,65
0,60
0,65
0,66
0,72
0,60
0,65
0,44
0,48
0,32
0,34
0,60
0,65
0,60
0,65
0,60
0,65

mm2

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x2

2,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

l4cm-2p60-en_d_te

14

Lowara
L4C MOTOR SERIES
L4CT OPERATING CHARACTERISTICS - 60Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

SERVICE

TYPE

POWER

FACTOR VOLTAGE

RATED

OPERATING CHARACTERISTICS

DIRECT

MAX

AT FULL (S.F.) POWER

STARTING

WATER

CABLE TYPE

TEMPERATURE Nc x sec
THREE-PHASE

kW

HP

S. F.

L4C03T236

0,37

0,5

1,6

L4C05T236

0,55

0,75

1,5

L4C07T236

0,75

1,4

L4C11T236

1,1

1,5

1,3

L4C15T236

1,5

1,25

L4C22T236

2,2

1,15

L4C30T236

1,15

L4C40T236

5,5

1,15

L4C55T236

5,5

7,5

1,15

L4C03T386
L4C05T386
L4C07T386
L4C11T386
L4C15T386
L4C22T386
L4C30T386
L4C40T386
L4C55T386
L4C75T386

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5

0,5
0,75
1
1,5
2
3
4
5,5
7,5
10

1,6
1,5
1,4
1,3
1,25
1,15
1,15
1,15
1,15
1,15

rpm

cos

Ts/Tn*

Is/In

220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
380
380
380
380
380
380
380
380
380
380

3,5
3,8
4,6
4,8
5,3
5,6
7,5
7,8
9,4
9,8
11,5
12
16,5
17,3
18,8
19,2
25,4
26
2,3
2,9
3,4
4,7
5,9
7,2
9,5
11,6
15,7
20

3400
3415
3440
3450
3450
3460
3450
3465
3470
3490
3450
3470
3460
3480
3470
3490
3480
3500
3415
3450
3460
3465
3490
3470
3460
3490
3500
3480

57,0
51,0
58,0
56,0
69,0
65,0
68,0
65,0
73,0
70,0
76,0
72,0
73,0
72,0
82,0
78,0
83,0
80,0
51,0
56,0
65,0
65,0
70,0
72,0
73,0
78,0
80,0
81,0

0,78
0,76
0,82
0,77
0,74
0,72
0,75
0,72
0,71
0,68
0,77
0,75
0,73
0,70
0,80
0,78
0,80
0,78
0,76
0,77
0,72
0,72
0,68
0,75
0,73
0,78
0,78
0,80

3,2
3,4
3,6
4,0
4,2
4,8
4,1
4,5
5,0
5,4
4,8
5,2
4,2
4,4
4,0
4,4
3,8
4,2
3,2
3,6
4,2
4,1
5,0
4,8
4,2
4,0
3,8
3,9

4,6
5,0
5,1
5,4
5,3
5,7
6,0
6,6
6,1
6,7
6,6
7,1
7,2
7,5
6,8
7,4
6,9
7,5
5,2
5,8
5,8
6,6
6,8
7,1
7,2
7,5
7,5
7,1

* Ts/Tn = ratio between starting torque and nominal torque.

mm

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1.5

1,7

35

4x1,5

2,7

35

4x2

2,7

35

4x2

2,7

35
35
35
35
35
35
35
35
35
35

4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
4x1,5
4x1.5
4x1.5
4x2

1,7
1,7
1,7
1,7
1,7
1,7
1,7
2,7
2,7
3,5

l4ct-2p60-en_d_te

15

Lowara

16

Lowara
6
Submersible
motors

Submersible canned motors.


The choice of component materials ensures optimum
operating performances, superior quality, reliability and
ease of installation.

L6C Series
60 Hz

SPECIFICA
TIONS
SPECIFICATIONS

Stainless steel outer sleeve.


Shaft extension and coupling
dimensions to NEMA standards.
Class F insulation
insulation.
Protection class: IP68
IP68.
Compensating bellows for internal
liquid expansion.
Axial load supported by Kingsbury
type thrust bearing.
Mechanical seal protected by
sand guard.
Maximum immersion depth
depth:
250 m.
Maximum number of starts per
hour at regular intervals:
25 for direct start.
Maximum supply voltage
variations allowed: 10%.
Maximum water temperature
temperature:
35C.
Max. temperature applies to motors
working in an installation capable of
delivering a flow of water around the
motor jacket of at least 0,2 m/s.

High starting
torque
Power supply
cable with
extractable
connector

17

Axial thrust
thrust:
16000 N from 4 to 22 kW;
27000 N from 30 to 37 kW.
Extractable supply cable
fitted with watertight connector.
Versions
ersions:
- Three-phase:
4 to 22 kW 230 V, 60 Hz.
4 to 37 kW 380 V, 60 Hz.
4 to 37 kW 460 V, 60 Hz.
Motors with double cable outlet for
star/delta start can be supplied upon
request.
Can also operate in horizontal
position, provided that the associated
pump can apply an axial thrust of at
least 250 N on the entire operating
field.
Screws included.

OPTIONAL FEA
TURES
FEATURES

Silicon Carbide mechanical seal.


Special voltages.
Inverter applications.
Temperature sensor PT 100 / PTC
PTC.

Lowara
L6C MOTOR SERIES
MOTOR CROS
S SECTION AND T
ABLE OF MA
TERIALS
CROSS
TABLE
MATERIALS

TABELLA MATERIALI L6C


REF.

PART

DESIGNATION

MATERIAL

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

EUROPE

Inner and outer sleeve


Flange
Shaft extension
Upper bracket
Intermediate bracket
Mechanical seal
Elastomers
Lower bracket
Compensating bellows
Bearings
Cable
Fixed sand guard
Removable sand guard
Bolts and screws
Lower cover
Mechanical seal spacer
Sand guard gasket
Cooling liquid

Stainless steel
EN 10088-1-X2CrNi18-9 (1.4307)
Carbon steel
EN 10025 - S355JR (Fe 510-B)
Stainless steel (Duplex) EN 10095 X3CrNiMoN27-5-2 (1.4460)
Cast iron
EN-GJL-200
Cast iron
EN-GJL-200
Carbon graphite / Aluminium oxide
NBR
Cast iron
EN-GJL-200
NBR
Carbon-graphite
EPDM
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
NBR
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
A105 nichel plated
CR neoprene
Demineralized water + antifreeze

USA

AISI304L
ASTM A105
AISI329
Class 25 B
Class 25 B

Class 25 B

AISI304
AISI304
AISI304

l6c-2p50-en_d_tm

18

Lowara
L6C MOTOR SERIES
IDENTIFICA
TION CODE
IDENTIFICATION
L6C

110

38

/_

VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L6C SERIES NAME
EXAMPLE : L6C110T386
L6C MOTOR :
RATED POWER 11 kW; THREE-PHASE;
RATED VOLTAGE 380 V; 60 Hz.

RA
TING PLA
TE
RATING
PLATE

LEGEND
1 - Motor type
2 - Code
3 - Maximum water temperature
4 - Minimum water velocity
5 - Insulation class
6 - Protection class
7 - Weight
8 - Maximum immersion depht
9 - Operating characteristics
10 - Production date
11 - Serial number
12 - Characteristics at service factor
13 - Service type

19

Lowara
L6C MOTOR SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT

DIMENSIONI E PESI MOTORI L6C - 2 poli 60Hz


RATED POWER

MOTOR

DIMENSIONS mm

WEIGHT

TYPE

kW

HP

kg

L6C40T236-386-405
L6C55T236-386-405
L6C75T236-386-405
L6C93T236-386-405
L6C110T236-386-405
L6C150T236-386-405
L6C185T236-386-405
L6C220T236-386-405
L6C300T386-405
L6C370T386-405

4
5,5
7,5
9,3
11
15
18,5
22
30
37

5,5
7,5
10
12,5
15
20
25
30
40
50

600
631
660
685
730
785
860
920
1050
1180

39,4
43,2
45,2
48,8
52,8
59
66,4
72,4
85
98
l6c-2p60-en_c_td

20

Lowara
L6C MOTOR SERIES
OPERATING CHARACTERISTICS AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

SERVICE

RATED

OPERATING CHARACTERISTICS

DIRECT

MAX

TYPE

POWER

FACTOR

VOLTAGE

AT FULL (S.F.) POWER

STARTING

WATER

rpm

cos

Ts/Tn*

Is/In

230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
380
460
380
460

19,0
11,5
9,5
26,6
16,1
13,1
33,0
20,0
16,5
41,2
25,0
20,6
46,6
28,2
23,3
61,6
37,3
30,8
80,0
48,4
40
99,6
60,2
49,8
75,0
62,0
90,0
77,0

3470
3470
3470
3450
3450
3450
3440
3440
3440
3450
3450
3450
3465
3465
3465
3440
3440
3440
3440
3440
3440
3440
3440
3440
3440
3440
3440
3440

79,0
79,0
79,0
77,0
77,0
77,0
80,0
80,0
80,0
82,0
82,0
82,0
85,0
85,0
85,0
85,0
85,0
85,0
86,0
86,0
86,0
86,0
86,0
86,0
85,0
85,0
84,0
84,0

0,80
0,80
0,80
0,80
0,80
0,80
0,81
0,81
0,81
0,80
0,80
0,80
0,82
0,82
0,82
0,83
0,83
0,83
0,80
0,80
0,80
0,77
0,77
0,77
0,82
0,82
0,88
0,88

1,7
1,7
1,7
1,8
1,8
1,8
2,0
2,0
2,0
2,1
2,1
2,1
2,2
2,2
2,2
2,4
2,4
2,4
2,5
2,5
2,5
2,6
2,6
2,6
2,6
2,6
2,6
2,6

5,45
5,50
5,54
5,00
5,00
5,00
5,45
5,50
5,50
4,80
4,80
4,80
5,20
5,20
5,20
5,45
5,45
5,45
5,70
5,70
5,70
5,80
5,80
5,80
6,20
6,20
6,20
6,20

CABLE TYPE

TEMPERATURE Nc x sec
THREE-PHASE

L6C40T236
L6C40T386
L6C40T405
L6C55T236
L6C55T386
L6C55T405
L6C75T236
L6C75T386
L6C75T405
L6C93T236
L6C93T386
L6C93T405
L6C110T236
L6C110T386
L6C110T405
L6C150T236
L6C150T386
L6C150T405
L6C185T236
L6C185T386
L6C185T405
L6C220T236
L6C220T386
L6C220T405
L6C300T386
L6C300T405
L6C370T386
L6C370T405

kW

HP

S. F.

5,5

1,15

5,5

7,5

1,15

7,5

10

1,15

9,3

12,5

1,15

11

15

1,15

15

20

1,15

18,5

25

1,15

22

30

1,15

30

40

1,15

37

50

1,15

* Ts/Tn = ratio between starting torque and nominal torque.

35

35

35

35

35

35

35

35
35
35

mm

4x4
4x4
4x4
4x4
4x4
4x4
4x4
4x4
4x4
4x6
4x4
4x4
4x6
4x4
4x4
4x6
4x4
4x4
4x8
4x6
4x6
4x8
4x6
4x6
4x8
4x6
4x8
4x8

L
m

4
4

l6c-2p60-en_e_te

21

Lowara

22

Lowara
6
Submersible
motors
L6W Series
60 Hz

Water filled submersible motors.


The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.

SPECIFICA
TIONS
SPECIFICATIONS

Stainless steel outer sleeve.


Shaft extension and coupling
dimensions to NEMA standards.
Rewindable stator
stator.
Class Y insulation
insulation.
Protection class: IP68
IP68.
Compensating bellows for internal
liquid expansion.
Axial load supported by Kingsbury
type thrust bearing.
Mechanical seal
protected by sand guard.
depth:
Maximum immersion depth
350 m.
Maximum number of starts per
hour at regular intervals: 15.
Maximum supply voltage
variations allowed : 10%.
temperature:
Maximum water temperature
30C.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket as following:
Standard versions 0,2 m/s (49,3 kW),
0,3 m/s (1130 kW) and
0,5 m/s (37 kW).
HT versions 0,2 m/s (5,57,5 kW),
0,3 m/s (9,326 kW) and
0,5 m/s (30 kW).
Axial thrust
thrust:
16000 N from 4 to 22 kW;
30000 N from 26 to 37 kW.
Power supply cable suitable
for drinkable water.
Versions
ersions:
- Three-phase:
4 to 18,5 kW, DOL 230 V, 60 Hz.
4 to 30 kW, Y/D 230 V, 60 Hz.
4 to 37 kW 380 V, 60 Hz.
4 to 37 kW 460 V, 60 Hz.

Rewindable
stator
Thrust bearing
Kingsbury
type
Mechanical
seal

23

Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
pump to the motor.
Flat power supply cable.
Screws included.

SPECIAL VERSIONS
Motors with double cable outlet for
star/delta start.
series: complete range
L6WN series
available realized of AISI 316
stainless steel.
series: complete range
L6WR series
available realized of Duplex
stainless steel.
series: complete range
HT series
available for all the L6W/N/R
construction, realized for applications
in high temperature environments
up to 60C
(up
60C) or under inverter.

OPTIONAL FEA
TURES
FEATURES

Silicon Carbide mechanical seal.


Special voltages.

ACCES
SORIES
ACCESSORIES

Temperature sensor PT 100 / PTC


PTC.

Lowara
L6W - L6WN - L6WR MOTOR SERIES
MOTOR CROS
S SECTION
CROSS

24

Lowara

MOTORI SERIE L6W: TABELLA MATERIALI


L6W T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

PART

DESIGNATION

MATERIAL
EUROPE

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Upper bracket
Spacer
Filling plug + OR
Vent valve
Cable
Cable gland plate
Cable gland
Shaft end
Removable sand guard
Mechanical seal cover
Mechanical seal
Bush bearings
Elastomers
Motor sleeve
Lower bracket
Thrust bearing bracket
Diaphragm
Lower cover
Bolts and screws
Cooling liquid
MOTORI
SERIE L6WN:

USA

Cast iron
EN-GJL-200
Cast iron
EN-GJL-200
Stainless steel+NBR
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EPR
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
EPDM
Stainless steel
EN 10088-1-X20Cr13 (1.4021)
EPDM
Stainless steel
EN 10213-4-GX5CrNi19-10 (1.4308)
Carbon graphite / Aluminium oxide
Carbon graphite
NBR
Stainless steel
EN 10088-1-X2CrNi19-11 (1.4306)
Cast iron
EN-GJL-200
Cast iron
EN-GJL-200
EPDM
Cast iron
EN-GJL-200
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Water + antifreeze
TABELLA
MATERIALI

Class 25 B
Class 25 B
AISI 316
AISI 316
AISI304
AISI420
ASTM CF-8 (AISI 304 cast)

AISI304L
Class 25 B
Class 25 B
Class 25 B
AISI304

L6WN T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

PART

L6w-2p50-en_b_tm

DESIGNATION

MATERIAL
EUROPE

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Upper bracket
Spacer
Filling plug + OR
Vent valve
Cable
Cable gland plate
Cable seal
Shaft end
Removable sand guard
Mechanical seal cover
Mechanical seal
Bush bearings
Elastomers
Motor sleeve
Lower bracket
Thrust bearing bracket
Diaphragm
Lower cover
Bolts and screws
Cooling liquid
MOTORI
SERIE L6WR:

USA

Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel+NBR
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EPR
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EPDM
Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EPDM
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Carbon graphite / Aluminium oxide
Carbon graphite
NBR
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
EPDM
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Water + antifreeze
TABELLA
MATERIALI

ASTM CF-8M (AISI 316 cast)


ASTM CF-8M (AISI 316 cast)
AISI 316
AISI 316
AISI 316
A276/A790-S31803
ASTM CF-8M (AISI 316 cast)

AISI 316L
ASTM CF-8M (AISI 316 cast)
ASTM CF-8M (AISI 316 cast)
ASTM CF-8M (AISI 316 cast)
AISI 316

L6WR T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

PART

L6wn-2p50-en_b_tm

DESIGNATION

MATERIALE
EUROPE

Upper bracket
Spacer
Filling plug + OR
Vent valve
Cable
Cable gland plate
Cable gland
Shaft end
Removable sand guard
Mechanical seal cover
Mechanical seal
Bush bearings
Elastomers
Motor sleeve
Lower bracket
Thrust bearing bracket
Diaphragm
Lower cover
Bolts and screws
Cooling liquid

Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)


Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex s. s.+NBR
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EPR
Stainless steel
EN 10088-1X1NiCrMoCu25-20-5 (1.4539)
EPDM
Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EPDM
Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Carbon graphite / Aluminium oxide
Carbon graphite
NBR
Stainless steel
EN 10088-1X1NiCrMoCu25-20-5 (1.4539)
Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
EPDM
Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Water + antifreeze

USA

A276/A790-S31803
A276/A790-S31803
AISI 904L
A276/A790-S31803
A276/A790-S31803

AISI 904L

A276/A790-S31803
L6wr-2p50-en_b_tm

25

Lowara
L6W MOTOR SERIES
IDENTIFICA
TION CODE
IDENTIFICATION
L6W

110

38

/_

HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L6W (CAST IRON STANDARD VERSION)
L6WN (AISI 316 VERSION)
L6WR (DUPLEX VERSION)

EXAMPLE : L6W110T386/A HT
L6W MOTOR :
RATED POWER 11 kW; THREE-PHASE;
RATED VOLTAGE 380 V; 60 Hz; /A VERSION; HIGH TEMPERATURE

RA
TING PLA
TE
RATING
PLATE

LEGEND
1 - Motor type
2 - Code
3 - Maximum water temperature
4 - Minimum water velocity
5 - Insulation class
6 - Protection class

7 - Weight
8 - Maximum immersion depht
9 - Operating characteristics
10 - Production date
11 - Serial number
12 - Characteristics at service factor

26

Lowara
L6W MOTOR SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT

DIMENSIONI E PESI MOTORI L6W - 2 poli 50 Hz


MOTOR

RATED

TYPE

POWER
kW

DIMENSIONS (mm)
HP

L6W40T236-386-405
4
5,5
583
L6W55T236-386-405
5,5
7,5
613
L6W75T236-386-405
7,5
10
653
L6W93T236-386-405
9,3
12,5
683
L6W110T236-386-405
11
15
723
L6W130T236-386-405
13
17,5
763
L6W150T236-386-405
15
20
833
L6W185T236-386-405
18,5
25
903
L6W220T236-386-405
22
30
943
L6W260T236-386-405
26
35
1071
L6W300T236-386-405
30
40
1151
DIMENSIONI
E PESI MOTORI
L6W
HT - 2 poli
50 Hz
L6W370T236-386-405
37
50
1301

WEIGHT
kg

38
42
46
50
54
58
66
74
77
86
94
108
l6w-2p60_a_td

MOTOR

RATED

TYPE

POWER

L6W40T236-386-405 HT
L6W55T236-386-405 HT
L6W75T236-386-405 HT
L6W93T236-386-405 HT
L6W110T236-386-405 HT
L6W130T236-386-405 HT
L6W150T236-386-405 HT
L6W185T236-386-405 HT
L6W220T236-386-405 HT
L6W260T236-386-405 HT
L6W300T236-386-405 HT

DIMENSIONS (mm)

WEIGHT

kW

HP

kg

4
5,5
7,5
9,3
11
13
15
18,5
22
26
30

5,5
7,5
10
12,5
15
17,5
20
25
30
35
40

613
653
683
723
763
833
903
943
1071
1151
1301

42
46
50
54
58
66
74
77
86
94
108
l6w-ht-2p60_a_td

27

Lowara
L6W MOTOR SERIES
OPERATING CHARACTERISTICS AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT ON-LINE

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

SERVICE SERVICE

MAX

AMPS

TEMP.
Sec. (mm2)

THREE-PHASE
kW

L6W40T236
L6W40T386
L6W40T405
L6W55T236
L6W55T386
L6W55T405
L6W75T236
L6W75T386
L6W75T405
L6W93T236
L6W93T386
L6W93T405
L6W110T236
L6W110T386
L6W110T405
L6W130T236
L6W130T386
L6W130T405
L6W150T236
L6W150T386
L6W150T405
L6W185T236
L6W185T386
L6W185T405
L6W220T236
L6W220T386
L6W220T405
L6W260T236
L6W260T386
L6W260T405
L6W300T236
L6W300T386
L6W300T405
L6W370T386
L6W370T405

CABLE TYPE

FACTOR FACTOR WATER

HP

5,5

5,5

7,5

7,5

10

9,3 12,5

11

15

13

17,5

15

20

18,5

25

22

30

26

35

30

40

37

50

rpm

cos

Is/In

Ts/Tn Tmax/Tn

230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
380
460

17,3
9,94
8,09
24,3
13,7
10,9
30,6
17,4
14,1
37,6
21,3
17,3
43,5
24,7
20,2
52,5
29,5
23,3
56,4
32,5
27,2
71,1
40,4
32,6
82,5
47,5
40,0
107
59,8
47,8
112
64,9
53,9
86,2
68,6

3500
3490
3485
3505
3495
3490
3500
3490
3485
3495
3485
3480
3490
3480
3475
3495
3485
3475
3485
3470
3475
3495
3485
3480
3510
3500
3500
3510
3500
3495
3510
3500
3505
3495
3490

72,8
73,0
73,0
75,4
76,3
76,8
78,2
78,8
78,9
79,4
79,9
80,0
80,3
80,7
80,8
80,5
81,2
81,4
83,1
83,3
83,3
83,4
83,8
83,9
84,8
84,7
84,7
84,4
85,0
85,0
84,4
84,4
84,5
83,4
83,6

0,80
0,84
0,85
0,75
0,80
0,82
0,79
0,83
0,84
0,78
0,83
0,84
0,79
0,84
0,85
0,77
0,82
0,86
0,80
0,84
0,83
0,78
0,83
0,85
0,79
0,83
0,82
0,72
0,78
0,80
0,79
0,83
0,83
0,78
0,81

4,51
4,75
4,82
5,01
5,38
5,59
5,33
5,67
5,78
5,52
5,90
6,00
5,38
5,73
5,79
5,33
5,74
6,00
6,21
6,52
6,44
6,24
6,65
6,81
5,70
5,99
5,88
5,45
5,90
6,10
6,04
6,31
6,28
5,40
5,61

1,28
1,29
1,29
1,59
1,60
1,60
1,69
1,70
1,70
1,84
1,85
1,85
1,52
1,53
1,53
1,66
1,67
1,67
1,93
1,94
1,94
2,39
2,40
2,40
0,98
0,98
0,98
1,17
1,18
1,18
2,49
2,49
2,49
1,32
1,32

Ts/Tn = ratio between starting torque and nominal torque.

2,01
2,02
2,02
2,54
2,55
2,55
2,49
2,50
2,50
2,69
2,70
2,70
2,56
2,57
2,57
2,55
2,55
2,56
3,02
3,03
3,03
3,10
3,11
3,11
2,95
2,96
2,96
2,81
2,82
2,82
2,75
2,75
2,75
2,63
2,63

SF

1,15

1,15

1,15

1,15

1,15

1,15

1,15

1,15

1,15

1,15

1,15
1,15

SFA

19,0
11,2
9,16
26,4
15,1
12,2
33,6
19,4
15,8
41,3
23,8
19,5
47,9
27,8
22,8
57,4
32,9
26,4
62,5
36,6
30,5
78,2
45,1
36,7
91,9
53,8
45,0
117
66,5
53,7
126
72,6
61,0
95,9
77,1

DOL

Y/D L (m)

30

30

30

30

6
30

4
6

30

4
10

30

30

30

30

30
30

4
10
4
6
-

6
4

10

10

10

10

6
4

6
4

4
4

l6w-2p60_d_te

Tmax/Tn = ratio between maximum torque and nominal torque.

28

Lowara
L6W HT MOTOR SERIES
OPERATING CHARACTERISTICS L6W HT AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT ON-LINE

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

SERVICE SERVICE

MAX

AMPS

TEMP.
2

THREE-PHASE

Sec. (mm )
kW

L6W40T236 HT
L6W40T386 HT
L6W40T405 HT
L6W55T236 HT
L6W55T386 HT
L6W55T405 HT
L6W75T236 HT
L6W75T386 HT
L6W75T405 HT
L6W93T236 HT
L6W93T386 HT
L6W93T405 HT
L6W110T236 HT
L6W110T386 HT
L6W110T405 HT
L6W130T236 HT
L6W130T386 HT
L6W130T405 HT
L6W150T236 HT
L6W150T386 HT
L6W150T405 HT
L6W185T236 HT
L6W185T386 HT
L6W185T405 HT
L6W220T236 HT
L6W220T386 HT
L6W220T405 HT
L6W260T236 HT
L6W260T386 HT
L6W260T405 HT
L6W300T386 HT
L6W300T405 HT

CABLE TYPE

FACTOR FACTOR WATER

HP

5,5

5,5

7,5

7,5

10

9,3 12,5

11

15

13

17,5

15

20

18,5

25

22

30

26

35

30

40

rpm

cos

Is/In

Ts/Tn Tmax/Tn

230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
380
460

21,3
11,5
9,04
26,2
14,4
11,5
33,5
18,5
14,9
39,5
22,0
17,8
48,2
26,4
20,5
56,5
31,3
24,6
63,3
35,0
28,0
74,1
41,6
35,0
97,7
53,5
42,3
102
57,7
48,0
75,2
58,8

3530
3525
3520
3525
3520
3520
3515
3510
3505
3510
3500
3495
3515
3505
3500
3510
3500
3495
3515
3510
3505
3520
3515
3520
3525
3520
3515
3525
3515
3520
3520
3515

72,3
74,0
74,9
76,1
77,6
78,0
78,2
79,4
79,7
79,8
80,8
81,0
79,9
71,1
81,7
81,9
82,9
83,5
82,7
83,5
83,9
84,6
85,2
85,0
84,0
85,0
85,2
84,4
84,7
84,7
83,7
84,2

0,65
0,71
0,74
0,69
0,75
0,77
0,72
0,78
0,79
0,74
0,80
0,81
0,72
0,78
0,82
0,71
0,76
0,80
0,72
0,78
0,80
0,74
0,79
0,78
0,67
0,73
0,77
0,76
0,81
0,80
0,73
0,76

5,74
6,43
6,76
6,23
6,86
7,10
6,21
6,81
6,98
5,87
6,38
6,51
5,81
6,42
6,83
6,21
6,78
7,13
7,02
7,68
7,93
6,77
7,30
7,17
5,97
6,59
6,89
6,64
7,10
7,05
6,19
6,54

2,21
2,21
2,21
2,34
2,34
2,34
2,30
2,31
2,31
1,81
1,82
1,82
1,98
1,99
1,99
2,24
2,25
2,25
2,98
2,99
2,99
1,94
1,94
1,94
1,40
1,40
1,40
2,89
2,89
2,89
1,64
1,64

Ts/Tn = ratio between starting torque and nominal torque.

3,52
3,52
3,53
3,45
3,45
3,45
3,36
3,37
3,37
3,05
3,06
3,06
3,04
3,05
3,05
3,50
3,51
3,52
3,86
3,86
3,87
3,25
3,25
3,25
3,35
3,36
3,36
3,19
3,19
3,19
3,28
3,28

SF

1,15

1,15

1,15

1,15

1,15

1,15

1,15

1,15

1,15

1,15
1,15

SFA

22,4
12,3
9,74
27,9
15,5
12,5
36,0
20,2
16,4
42,7
24,2
19,7
51,7
28,9
22,8
60,7
34,1
27,1
68,2
38,3
30,9
81,2
46,3
38,8
105
58,6
46,8
112
64,8
53,7
82,1
64,9

DOL

Y/D L (m)

45

45

45

6
45

4
6

45

4
10

45

45

45

45

45
45

4
10
4
6
6
6
10

6
4

10
4

6
-

10

10

10

6
4

4
4

l6w-ht-2p60_b_te

Tmax/Tn = ratio between maximum torque and nominal torque.

29

Lowara

30

Lowara
8
Submersible
motors
L8W Series
60 Hz

Rewindable
stator

Water filled submersible motors.


The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.

SPECIFICA
TIONS
SPECIFICATIONS

SPECIAL VERSIONS

Stainless steel outer sleeve.


Shaft extension and coupling
dimensions to NEMA standards.
Rewindable stator
stator.
Class Y insulation
insulation.
Protection class: IP68
IP68.
Compensating bellows for internal
liquid expansion.
Axial load supported by Kingsbury
type thrust bearing.
Mechanical seal
protected by sand guard.
Maximum immersion depth
depth:
350 m.
Maximum number of starts per
hour at regular intervals: 10.
Maximum supply voltage
variations allowed : 10%.
Maximum water temperature
temperature:
30C.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket of at least 0,5 m/s.
Axial thrust
thrust:
50000 N from 30 to 93 kW.
Power supply cable suitable
for drinkable water.
Versions
ersions:
- Three-phase:
30 to 93 kW 380 V, 60 Hz.
30 to 93 kW 460 V, 60 Hz.
Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
pump to the motor.

Thrust bearing
Kingsbury
type
Mechanical
seal

31

Motors with double cable outlet for


star/delta start.
L8WN series
series: complete range
available realized of AISI 316
stainless steel.
L8WR series
series: complete range
available realized of Duplex
stainless steel.
HT series
series: complete range
available for all the L8W/N/R
construction, realized for applications
in high temperature environments
up to 60C
(up
60C) or under inverter.

OPTIONAL FEA
TURES
FEATURES

Silicon Carbide mechanical seal.


Special voltages.

ACCES
SORIES
ACCESSORIES

Temperature sensor PT 100 / PTC


PTC.

Lowara
L8W - L8WN - L8WR MOTOR SERIES
MOTOR CROS
S SECTION
CROSS

32

Lowara

L8W MOTOR SERIES: TABLE OF MATERIALS


L8W T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

PART

DESIGNATION

MATERIAL
EUROPE

USA

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Upper bracket
Cast iron
EN-GJL-200
Cast iron
EN-GJL-200
Spacer
Stainless steel+NBR
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling plug + OR
Vent valve
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cable
EPR
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Cable gland plate
EPDM
Cable gland
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Shaft end
Duplex stainless steel
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Removable sand guard
Mechanical seal cover
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Mechanical seal
Carbon graphite / Aluminium oxide
Carbon graphite
Bush bearings
Elastomers
NBR
Motor sleeve
Stainless steel
EN 10088-1-X2CrNi19-11 (1.4306)
Lower bracket
Cast iron
EN-GJL-200
Cast iron
EN-GJL-200
Thrust bearing bracket
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling valve
EPDM
Diaphragm
Lower cover
Cast iron
EN-GJL-200
Bolts and screws
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
liquid
WaterTABLE
+ antifreeze
Cooling
L8WN
MOTOR
SERIES:
OF MATERIALS

Class 25 B
Class 25 B
AISI 316
AISI 316
AISI304
A276/A790-S31803
AISI 316L
AISI 316L

AISI304L
Class 25 B
Class 25 B
AISI 316
Class 25 B
AISI304

L8WN T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

PART

L8w-2p50-en_a_tm

DESIGNATION

MATERIAL
EUROPE

USA

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Upper bracket
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Spacer
Stainless steel+NBR
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling plug + OR
Vent valve
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cable
EPR
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cable gland plate
EPDM
Cable gland
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Shaft end
Duplex stainless steel
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Removable sand guard
Mechanical seal cover
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Mechanical seal
Carbon graphite / Aluminium oxide
Carbon graphite
Bush bearings
Elastomers
NBR
Motor sleeve
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Lower bracket
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Thrust bearing bracket
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling valve
EPDM
Diaphragm
Lower cover
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Bolts and screws
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
liquid
WaterTABLE
+ antifreeze
Cooling
L8WR
MOTOR
SERIES:
OF MATERIALS

ASTM CF-8M (AISI 316 cast)


ASTM CF-8M (AISI 316 cast)
AISI 316
AISI 316
AISI 316
A276/A790-S31803
AISI 316L
AISI 316L

AISI 316L
ASTM CF-8M (AISI 316 cast)
ASTM CF-8M (AISI 316 cast)
AISI 316
ASTM CF-8M (AISI 316 cast)
AISI 316

L8WR T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

PART

L8wn-2p50-en_a_tm

DESIGNATION

MATERIAL
EUROPE

Upper bracket
Spacer
Filling plug + OR
Vent valve
Cable
Cable gland plate
Cable gland
Shaft end
Removable sand guard
Mechanical seal cover
Mechanical seal
Bush bearings
Elastomers
Motor sleeve
Lower bracket
Thrust bearing bracket
Filling valve
Diaphragm
Lower cover
Bolts and screws
Cooling liquid

Duplex stainless steel


EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex s. s.+NBR
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
EPR
Stainless steel
EN 10088-1X1NiCrMoCu25-20-5 (1.4539)
EPDM
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Carbon graphite / Aluminium oxide
Carbon graphite
NBR
Stainless steel
EN 10088-1X1NiCrMoCu25-20-5 (1.4539)
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
Duplex stainless steel
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EPDM
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Water + antifreeze

USA

A276/A790-S31803
A276/A790-S31803
AISI 904L
A276/A790-S31803
A276/A790-S31803
A276/A790-S31803

AISI 904L
A276/A790-S31803
A276/A790-S31803
L8wr-2p50-en_a_tm

33

Lowara
L8W MOTOR SERIES
IDENTIFICA
TION CODE
IDENTIFICATION
L8W

550

38

/_

HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L8W (CAST IRON STANDARD VERSION)
L8WN (AISI 316 VERSION)
L8WR (DUPLEX VERSION)

EXAMPLE : L8W550T386/A HT
L8W MOTOR :
RATED POWER 55 kW; THREE-PHASE;
RATED VOLTAGE 380 V; 60 Hz; /A VERSION; HIGH TEMPERATURE

RA
TING PLA
TE
RATING
PLATE

LEGEND
1 - Motor type
2 - Code
3 - Maximum water temperature
4 - Minimum water velocity
5 - Insulation class
6 - Protection class

7 - Weight
8 - Maximum immersion depht
9 - Operating characteristics
10 - Production date
11 - Serial number
12 - Characteristics at service factor

34

Lowara
L8W MOTOR SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT

DIMENSIONI E PESI MOTORI L8W - 2 poli 60 Hz


MOTOR

RATED

TYPE

POWER
kW

DIMENSIONS (mm)
HP

L8W300T386-405
30
40
1015
L8W370T386-405
37
50
1105
L8W450T386-405
45
60
1195
L8W520T386-405
52
70
1285
L8W550T386-405
55
75
1325
L8W600T386-405
60
80
1375
L8W670T386-405
67
90
1465
L8W750T386-405
75
100
1555
L8W830T386-405
83
110
1615
DIMENSIONI
E PESI MOTORI
60 Hz
L8W930T386-405
93 L8W
125HT - 2 poli
1755

WEIGHT
kg

145
162
180
200
206
217
235
252
265
290
l8w-2p60_a_td

MOTOR

RATED

TYPE

POWER

L8W300T386-405 HT
L8W370T386-405 HT
L8W450T386-405 HT
L8W520T386-405 HT
L8W550T386-405 HT
L8W600T386-405 HT
L8W670T386-405 HT
L8W750T386-405 HT
L8W830T386-405 HT

DIMENSIONS (mm)

WEIGHT

kW

HP

kg

30
37
45
52
55
60
67
75
83

40
50
60
70
75
80
90
100
110

1105
1195
1285
1325
1375
1465
1555
1615
1755

162
180
200
206
217
235
252
265
290
l8w-ht-2p60_a_td

35

Lowara
L8W MOTOR SERIES
OPERATING CHARACTERISTICS AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT ON-LINE

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

SERVICE SERVICE

THREE-PHASE
kW

L8W300T386
L8W300T405
L8W370T386
L8W370T405
L8W450T386
L8W450T405
L8W520T386
L8W520T405
L8W550T386
L8W550T405
L8W600T386
L8W600T405
L8W670T386
L8W670T405
L8W750T386
L8W750T405
L8W830T386
L8W830T405
L8W930T386
L8W930T405

HP

30

40

37

50

45

60

52

70

55

75

60

80

67

90

75

100

83

110

93

125

380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460

67,8
56,0
83,5
69,0
99,3
82,0
116
96,0
121
100
130
107
146
121
162
134
179
148
201
166

rpm

cos

Is/In

Ts/Tn Tmax/Tn

SF

3470

81,5 0,83 5,50 1,04

2,22

1,15

3475

81,5 0,83 5,26 1,04

2,23

1,15

3480

83

0,83 4,98 0,98

2,22

1,15

3475

83

0,82 5,56 1,06

2,22

1,15

83,5 0,83 5,44 1,06

2,24

1,15

3475
3480

84

0,84 5,07 1,04

2,23

1,15

3480

84

0,83 5,13 1,03

2,23

1,15

3485

84

0,84 5,04 1,01

2,22

1,15

3485

84

0,84 4,79 0,97

2,28

1,15

3490

84

0,84

2,22

1,15

Ts/Tn = ratio between starting torque and nominal torque.

4,6

1,02

MAX

CABLE TYPE

FACTOR FACTOR WATER


AMPS

TEMP.

SFA

78,0
64,4
96,1
79,4
114
94,3
134
110
139
115
149
123
168
139
187
154
206
170
231
191

30
30
30
30
30
30
30
30
30
30

Sec. (mm2)
DOL

Y/D

10
10
16
10
16
16
25
16
25
16
25
16
35
25
35
25
35
35
50
35

6
4
6
6
10
6
10
10
10
10
16
10
16
10
16
16
16
16
25
16

L (m)

5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5

l8w-2p60_c_te

Tmax/Tn = ratio between maximum torque and nominal torque.

36

Lowara
L8W HT MOTOR SERIES
OPERATING CHARACTERISTICS L8W HT AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT ON-LINE

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

SERVICE SERVICE

THREE-PHASE
kW

L8W300T386 HT
L8W300T405 HT
L8W370T386 HT
L8W370T405 HT
L8W450T386 HT
L8W450T405 HT
L8W520T386 HT
L8W520T405 HT
L8W550T386 HT
L8W550T405 HT
L8W600T386 HT
L8W600T405 HT
L8W670T386 HT
L8W670T405 HT
L8W750T386 HT
L8W750T405 HT
L8W830T386 HT
L8W830T405 HT

HP

30

40

37

50

45

60

52

70

55

75

60

80

67

90

75

100

83

110

380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460

70,5
58,2
81,1
67,0
99,9
82,5
114
94,0
120
99,1
133
110
146
121
161
133
177
146

rpm

cos

Is/In

Ts/Tn Tmax/Tn

SF

3510

83,7 0,79 6,24 1,28

2,75

1,15

3515

84,0 0,80 6,09 1,19

2,70

1,15

3505

84,0 0,79 6,47 1,22

2,57

1,15

3495

84,0 0,83 5,79 1,12

2,37

1,15

3505

84,5 0,82 5,47 1,13

2,43

1,15

3505

85,3 0,81 5,64 1,15

2,49

1,15

3510

85,4 0,82 5,58 1,13

2,49

1,15

3505

83,6 0,83 5,33 1,07

2,52

1,15

3520

85,8 0,82 5,23 1,14

2,49

1,15

Ts/Tn = ratio between starting torque and nominal torque.

MAX

CABLE TYPE

FACTOR FACTOR WATER


AMPS

TEMP.

SFA

78,7
65,0
92,0
76,0
107
88,0
129
106
136
112
149
123
166
137
185
153
197
163

45
45
45
45
45
45
45
45
45

Sec. (mm2)
DOL

Y/D

10
10
16
10
16
16
25
16
25
16
25
16
35
25
35
25
35
35

6
4
6
6
10
6
10
10
10
10
16
10
16
10
16
16
16
16

L (m)

5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5

l8w-ht-2p60_a_te

Tmax/Tn = ratio between maximum torque and nominal torque.

37

Lowara

38

Lowara
10
Submersible
motors
L10W Series
60 Hz

Water filled submersible motors.


The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.

SPECIFICA
TIONS
SPECIFICATIONS

SPECIAL VERSIONS

Stainless steel outer sleeve.


Rewindable stator
stator.
Class Y insulation
insulation.
Protection class: IP68
IP68.
Compensating bellows for internal
liquid expansion.
Axial load supported by Kingsbury
type thrust bearing.
Mechanical seal
protected by sand guard.
Maximum immersion depth
depth:
350 m.
Maximum number of starts per
hour at regular intervals: 8.
Maximum supply voltage
variations allowed : 10%.
Maximum water temperature
temperature:
30C.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket of at least 0,5 m/s.
Axial thrust
thrust:
65000 N from 93 to150 kW.
Power supply cable suitable
for drinkable water.
Versions
ersions:
- Three-phase:
93 to 150 kW 380 V, 60 Hz.
93 to 150 kW 460 V, 60 Hz.
Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
pump to the motor.

Rewindable
stator
Thrust bearing
Kingsbury
type
Mechanical
seal
39

Motors with double cable outlet for


star/delta start.
L10WN series
series: complete range
available realized of AISI 316
stainless steel.
L10WR series
series: complete range
available realized of Duplex
stainless steel.
HT series
series: complete range
available for all the L10W/N/R
construction, realized for applications
in high temperature environments
up to 60C
(up
60C) or under inverter.

OPTIONAL FEA
TURES
FEATURES

Silicon Carbide mechanical seal.


Special voltages.

ACCES
SORIES
ACCESSORIES

Temperature sensor PT 100 / PTC


PTC.

Lowara
L10W - L10WN - L10WR MOTOR SERIES
MOTOR CROS
S SECTION
CROSS

40

Lowara

L10W MOTOR SERIES: TABLE OF MATERIALS


L10W T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

PART

DESIGNATION

MATERIAL
EUROPE

USA

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Upper bracket
Cast iron
EN-GJL-200
Cast iron
EN-GJL-200
Spacer
Stainless steel+NBR
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling plug + OR
Vent valve
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cable
EPR
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Cable gland plate
EPDM
Cable gland
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Shaft end
Duplex stainless steel
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Removable sand guard
Mechanical seal cover
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Mechanical seal
Carbon graphite / Aluminium oxide
Carbon graphite
Bush bearings
Elastomers
NBR
Motor sleeve
Stainless steel
EN 10088-1-X2CrNi19-11 (1.4306)
Lower bracket
Cast iron
EN-GJL-200
Cast iron
EN-GJL-200
Thrust bearing bracket
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling valve
EPDM
Diaphragm
Lower cover
Cast iron
EN-GJL-200
Bolts and screws
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
liquid
Water +
antifreezeOF MATERIALS
CoolingMOTOR
L10WN
SERIES:
TABLE

Class 25 B
Class 25 B
AISI 316
AISI 316
AISI304
A276/A790-S31803
AISI 316L
AISI 316L

AISI304L
Class 25 B
Class 25 B
AISI 316
Class 25 B
AISI304

L10WN T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

PART

L10w-2p50-en_a_tm

DESIGNATION

MATERIAL
EUROPE

USA

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Upper bracket
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Spacer
Stainless steel+NBR
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling plug + OR
Vent valve
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cable
EPR
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cable gland plate
EPDM
Cable gland
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Shaft end
Duplex stainless steel
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Removable sand guard
Mechanical seal cover
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Mechanical seal
Carbon graphite / Aluminium oxide
Carbon graphite
Bush bearings
Elastomers
NBR
Motor sleeve
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Lower bracket
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Thrust bearing bracket
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling valve
EPDM
Diaphragm
Lower cover
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Bolts and screws
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
liquid
Water +
antifreezeOF MATERIALS
CoolingMOTOR
L10WR
SERIES:
TABLE

ASTM CF-8M (AISI 316 cast)


ASTM CF-8M (AISI 316 cast)
AISI 316
AISI 316
AISI 316
A276/A790-S31803
AISI 316L
AISI 316L

AISI 316L
ASTM CF-8M (AISI 316 cast)
ASTM CF-8M (AISI 316 cast)
AISI 316
ASTM CF-8M (AISI 316 cast)
AISI 316

L10WR T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

PART

L10wn-2p50-en_a_tm

DESIGNATION

MATERIAL
EUROPE

Upper bracket
Spacer
Filling plug + OR
Vent valve
Cable
Cable gland plate
Cable gland
Shaft end
Removable sand guard
Mechanical seal cover
Mechanical seal
Bush bearings
Elastomers
Motor sleeve
Lower bracket
Thrust bearing bracket
Filling valve
Diaphragm
Lower cover
Bolts and screws
Cooling liquid

Duplex stainless steel


EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex s. s.+NBR
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
EPR
Stainless steel
EN 10088-1X1NiCrMoCu25-20-5 (1.4539)
EPDM
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Carbon graphite / Aluminium oxide
Carbon graphite
NBR
Stainless steel
EN 10088-1X1NiCrMoCu25-20-5 (1.4539)
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
Duplex stainless steel
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EPDM
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Water + antifreeze

USA

A276/A790-S31803
A276/A790-S31803
AISI 904L
A276/A790-S31803
A276/A790-S31803
A276/A790-S31803

AISI 904L
A276/A790-S31803
A276/A790-S31803
L10wr-2p50-en_a_tm

41

Lowara
L10W MOTOR SERIES
IDENTIFICA
TION CODE
IDENTIFICATION
L10W

1500

38

/_

HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L10W (CAST IRON STANDARD VERSION)
L10WN (AISI 316 VERSION)
L10WR (DUPLEX VERSION)

EXAMPLE : L10W1500T386/A HT
L10W MOTOR :
RATED POWER 150 kW; THREE-PHASE;
RATED VOLTAGE 380 V; 60 Hz; /A VERSION; HIGH TEMPERATURE

RA
TING PLA
TE
RATING
PLATE

LEGEND
1 - Motor type
2 - Code
3 - Maximum water temperature
4 - Minimum water velocity
5 - Insulation class
6 - Protection class

7 - Weight
8 - Maximum immersion depht
9 - Operating characteristics
10 - Production date
11 - Serial number
12 - Characteristics at service factor

42

Lowara
L10W MOTOR SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT

DIMENSIONI E PESI MOTORI L10W - 2 poli 60 Hz


MOTOR

RATED

TYPE

POWER

L10W930T386-405
L10W1100T386-405
L10W1300T386-405
L10W1500T386-405

DIMENSIONS (mm)

WEIGHT

kW

HP

kg

93
110
130
150

125
150
175
200

1562
1702
1852
1982

360
401
448
487

DIMENSIONI E PESI MOTORI L10W HT - 2 poli 60 Hz l10w-2p60_a_td


MOTOR

RATED

TYPE

POWER

L10W830T386-405 HT
L10W930T386-405 HT
L10W1100T386-405 HT
L10W1300T386-405 HT

DIMENSIONS (mm)

WEIGHT

kW

HP

kg

83
93
110
130

110
125
150
175

1562
1702
1852
1982

360
401
448
487
l10w-ht-2p60_a_td

43

Lowara
L10W MOTOR SERIES
OPERATING CHARACTERISTICS AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT ON-LINE

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

SERVICE SERVICE

THREE-PHASE
kW

HP

L10W930T386
93
L10W930T405
L10W1100T386
110
L10W1100T405
L10W1300T386
130
L10W1300T405
L10W1500T386
150
L10W1500T405

125
150
175
200

380
460
380
460
380
460
380
460

199
164
275
227
286
236
329
272

rpm

cos

Is/In

Ts/Tn Tmax/Tn

MAX

CABLE TYPE

FACTOR FACTOR WATER


SF

3510

85,0 0,84 5,55 1,02

2,22

1,15

3520

85,5 0,82 6,38 1,43

2,19

1,15

3520

85,5 0,81 6,31

1,5

2,22

1,15

3525

85,5 0,81 6,24 1,56

2,22

1,15

AMPS

TEMP.

SFA

228
189
316
261
329
271
379
313

30
30
30
30

Sec. (mm2)
DOL

Y/D

50
35
70
50
70
50
70
70

25
16
25
16
35
25
35
35

Ts/Tn = ratio between starting torque and nominal torque.

L (m)

5
5
5
5

l10w-2p60_b_te

Tmax/Tn = ratio between maximum torque and nominal torque.

L10W HT MOTOR SERIES


OPERATING CHARACTERISTICS L10W HT AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT ON-LINE

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

SERVICE SERVICE

THREE-PHASE
kW

L10W830T386 HT
L10W830T405 HT
L10W930T386 HT
L10W930T405 HT
L10W1100T386 HT
L10W1100T405 HT
L10W1300T386 HT
L10W1300T405 HT

HP

83

110

93

125

110 150
130 175

380
460
380
460
380
460
380
460

180
149
212
175
254
210
298
246

rpm

cos

Is/In

Ts/Tn Tmax/Tn

SF

3530

85,2 0,82 6,11 1,15

2,48

1,15

3545

86,0 0,78 8,27 1,69

2,58

1,15

3545

87,6 0,75 7,09 1,77

2,62

1,15

3550

86,4 0,77 6,90 1,80

2,56

1,15

Ts/Tn = ratio between starting torque and nominal torque.

MAX

CABLE TYPE

FACTOR FACTOR WATER


AMPS

TEMP.

SFA

202
167
236
195
281
232
330
273

45
45
45
45

Sec. (mm2)
DOL

Y/D

50
35
70
50
70
50
70
70

25
16
25
16
35
25
35
35

L (m)

5
5
5
5

l10w-ht-2p60_a_te

Tmax/Tn = ratio between maximum torque and nominal torque.

44

Lowara
12
Submersible
motors
L12W Series
60 Hz

Water filled submersible motors.


The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.

SPECIFICA
TIONS
SPECIFICATIONS

SPECIAL VERSIONS

Stainless steel outer sleeve.


Rewindable stator
stator.
Class Y insulation
insulation.
Protection class: IP68
IP68.
Compensating bellows for internal
liquid expansion.
Axial load supported by Kingsbury
type thrust bearing.
Mechanical seal
protected by sand guard.
Maximum immersion depth
depth:
350 m.
Maximum number of starts per
hour at regular intervals: 4.
Maximum supply voltage
variations allowed : 10%.
Maximum water temperature
temperature:
30C.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket of at least 0,5 m/s.
Axial thrust
thrust:
65000 N from 185 to 300 kW.
Power supply cable suitable
for drinkable water.
Versions
ersions:
- Three-phase:
185 to 300 kW 380 V, 60 Hz.
185 to 300 kW 460 V, 60 Hz.
Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
pump to the motor.

Rewindable
stator
Thrust bearing
Kingsbury
type
Mechanical
seal
45

Motors with double cable outlet for


star/delta start.
L12WN series
series: complete range
available realized of AISI 316
stainless steel.
L12WR series
series: complete range
available realized of Duplex
stainless steel.
HT series
series: complete range
available for all the L12W/N/R
construction, realized for applications
in high temperature environments
up to 60C
(up
60C) or under inverter.

OPTIONAL FEA
TURES
FEATURES

Silicon Carbide mechanical seal.


Special voltages.

ACCES
SORIES
ACCESSORIES

Temperature sensor PT 100 / PTC


PTC.

Lowara
L12W - L12WN - L12WR MOTOR SERIES
MOTOR CROS
S SECTION
CROSS

46

Lowara

L12W MOTOR SERIES: TABLE OF MATERIALS


L12W T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

PART

DESIGNATION

MATERIAL
EUROPE

Upper bracket
Filling plug + OR
Vent valve
Cable
Cable gland plate
Cable gland
Shaft end
Removable sand guard
Mechanical seal cover
Mechanical seal
Bush bearings
Elastomers
Stator flanges
Motor sleeve
Lower bracket
Thrust bearing bracket
Filling valve
Diaphragm
Lower cover
Bolts and screws
Cooling liquid

USA

Cast iron
EN-GJL-200
Stainless steel+NBR
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EPR
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EPDM
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Carbon graphite / Aluminium oxide
Carbon graphite
NBR
Steel
UNI 3158 - Fe 52
Stainless steel
EN 10088-1-X2CrNi19-11 (1.4306)
Cast iron
EN-GJL-200
Cast iron
EN-GJL-200
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EPDM
Cast iron
EN-GJL-200
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Water + antifreeze

Class 25 B
AISI 316
AISI 316
AISI 316
A276/A790-S31803
AISI 316L
AISI 316L

AISI304L
Class 25 B
Class 25 B
AISI 316
Class 25 B
AISI304

L12WN MOTOR SERIES: TABLE OF MATERIALS


ABLE OF MA
TERIALS
TABLE
MATERIALS
L12WN T
REF.
N

PART

L12w-2p50-en_a_tm

DESIGNATION

MATERIAL
EUROPE

USA

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Upper bracket
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Stainless steel+NBR
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling plug + OR
Vent valve
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cable
EPR
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cable gland plate
EPDM
Cable gland
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Shaft end
Duplex stainless steel
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Removable sand guard
Mechanical seal cover
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Mechanical seal
Carbon graphite / Aluminium oxide
Carbon graphite
Bush bearings
Elastomers
NBR
Stator flanges
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Motor sleeve
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Lower bracket
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Thrust bearing bracket
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Filling valve
EPDM
Diaphragm
Lower cover
Stainless steel
EN 10213-4 - GX5CrNiMo19-11-2 (1.4408)
Bolts and screws
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
liquid
Water +
antifreezeOF MATERIALS
CoolingMOTOR
L12WR
SERIES:
TABLE

ASTM CF-8M (AISI 316 cast)


AISI 316
AISI 316
AISI 316
A276/A790-S31803
AISI 316L
AISI 316L

AISI 316
AISI 316L
ASTM CF-8M (AISI 316 cast)
ASTM CF-8M (AISI 316 cast)
AISI 316
ASTM CF-8M (AISI 316 cast)
AISI 316

L12WR T
ABLE OF MA
TERIALS
TABLE
MATERIALS
REF.
N

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

PART

L12wn-2p50-en_a_tm

DESIGNATION

MATERIAL
EUROPE

Upper bracket
Filling plug + OR
Vent valve
Cable
Cable gland plate
Cable gland
Shaft end
Removable sand guard
Mechanical seal cover
Mechanical seal
Bush bearings
Elastomers
Stator flanges
Motor sleeve
Lower bracket
Thrust bearing bracket
Filling valve
Diaphragm
Lower cover
Bolts and screws
Cooling liquid

Duplex stainless steel


EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex s. s.+NBR
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
EPR
Stainless steel
EN 10088-1X1NiCrMoCu25-20-5 (1.4539)
EPDM
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Carbon graphite / Aluminium oxide
Carbon graphite
NBR
Duplex stainless steel
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Stainless steel
EN 10088-1X1NiCrMoCu25-20-5 (1.4539)
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
Duplex stainless steel
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
EPDM
EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)
Duplex stainless steel
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Water + antifreeze

USA

A276/A790-S31803
A276/A790-S31803
AISI 904L
A276/A790-S31803
A276/A790-S31803
A276/A790-S31803

AISI 904L
A276/A790-S31803
A276/A790-S31803
L12wr-2p50-en_a_tm

47

Lowara
L12W MOTOR SERIES
IDENTIFICA
TION CODE
IDENTIFICATION
L12W

3000

38

/_

HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L12W (CAST IRON STANDARD VERSION)
L12WN (AISI 316 VERSION)
L12WR (DUPLEX VERSION)

EXAMPLE : L12W3000T386/A HT
L12W MOTOR :
RATED POWER 300 kW; THREE-PHASE;
RATED VOLTAGE 380 V; 60 Hz; /A VERSION; HIGH TEMPERATURE

RA
TING PLA
TE
RATING
PLATE

LEGEND
1 - Motor type
2 - Code
3 - Maximum water temperature
4 - Minimum water velocity
5 - Insulation class
6 - Protection class

7 - Weight
8 - Maximum immersion depht
9 - Operating characteristics
10 - Production date
11 - Serial number
12 - Characteristics at service factor

48

Lowara
L12W MOTOR SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT

DIMENSIONI E PESI MOTORI L12W - 2 poli 60 Hz


MOTOR

RATED

TYPE

POWER

L12W1850T386-405
L12W2200T386-405
L12W2600T386-405
L12W3000T386-405

DIMENSIONS (mm)

WEIGHT

kW

HP

kg

185
220
260
300

250
300
350
400

1739
1889
2039
2189

552
616
680
745

DIMENSIONI E PESI MOTORI L12W HT - 2 poli 60 Hz


MOTOR

RATED

TYPE

POWER

L12W1500T386-405 HT
L12W1850T386-405 HT
L12W2200T386-405 HT
L12W2600T386-405 HT

DIMENSIONS (mm)

l12w-2p60_a_td

WEIGHT

kW

HP

kg

150
185
220
260

200
250
300
350

1739
1889
2039
2189

552
616
680
745
l12w-ht-2p60_a_td

49

Lowara
L12W MOTOR SERIES
OPERATING CHARACTERISTICS AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

SERVICE SERVICE

THREE-PHASE
kW

L12W1850T386
L12W1850T405
L12W2200T386
L12W2200T405
L12W2600T386
L12W2600T405
L12W3000T386
L12W3000T405

HP

185

250

220

300

260

350

300

400

380
460
380
460
380
460
380
460

387
320
466
385
541
447
620
512

rpm

cos

Is/In

MAX

CABLE TYPE

FACTOR FACTOR WATER

Ts/Tn Tmax/Tn

SF

3515

85,5 0,85 6,59 1,50

2,22

1,15

3515

85,5 0,84 6,66 1,41

2,22

1,15

3515

86,0 0,85 6,05 1,41

2,22

1,15

3515

86,5 0,85 6,43 1,18

2,22

1,15

AMPS

TEMP.

SFA

445
368
536
443
622
514
713
589

30
30
30
30

Sec. (mm2)
DOL

Y/D

95
70
120
95
150
120
2x70

50
35
70
50
70
50
95
70

Ts/Tn = ratio between starting torque and nominal torque.

L (m)

5
5
5
5

l12w-2p60_b_te

Tmax/Tn = ratio between maximum torque and nominal torque.

L12W HT MOTOR SERIES


OPERATING CHARACTERISTICS L12W HT AT 60 Hz
THREE-PHASE OPERA
TING CHARACTERISTIC
S A
T 60 Hz
OPERATING
CHARACTERISTICS
AT
MOTOR

RATED

RATED

OPERATING CHARACTERISTICS

DIRECT

TYPE

POWER

VOLTAGE

AT RATED POWER

STARTING

SERVICE SERVICE

THREE-PHASE
kW

L12W1850T386 HT
L12W1850T405 HT
L12W1850T386 HT
L12W1850T405 HT
L12W2200T386 HT
L12W2200T405 HT
L12W2600T386 HT
L12W2600T405 HT

HP

150 200
185 250
220 300
260 350

380
460
380
460
380
460
380
460

321
265
395
326
448
370
539
445

rpm

cos

Is/In Ts/Tn Tmax/Tn

SF

3545

88,0 0,82 7,96 1,85

2,74

1,15

3540

88,0 0,80 7,86 1,68

2,64

1,15

3535

89,0 0,82 7,31 1,67

2,62

1,15

3525

88,5 0,83 7,40 1,36

2,56

1,15

Ts/Tn = ratio between starting torque and nominal torque.

MAX

CABLE TYPE

FACTOR FACTOR WATER


AMPS

TEMP.

SFA

363
300
442
365
514
425
611
505

45
45
45
45

Sec. (mm2)
DOL

Y/D

95
70
120
95
150
120
2x70

50
35
70
50
70
50
95
70

L (m)

5
5
5
5

l12w-ht-2p60_a_te

Tmax/Tn = ratio between maximum torque and nominal torque.

50

Lowara
ACCES
SORIES
ACCESSORIES

52

Motor - Control Panel Combination Table .......................................................................................

55

Electrical Panels ...............................................................................................................................

63

Level control panel ..........................................................................................................................

64

Level probe module ........................................................................................................................

65

Lightning protection .......................................................................................................................

51

Lowara
4OS
- L4C
MOTORDISERIES
TABELLE
INDICATIVE
ABBINAMENTO MOTORE - QUADRO
MOTOR - CONTROL P
ANEL COMBINA
TION T
ABLE
PANEL
COMBINATION
TABLE
MOTOR TYPE

RATED

CURRENT

4OS - 4"

POWER

AT S.F.

SINGLE-PHASE

220-230 V
kW

TABELLE

PANEL TYPE

CAPACITOR

HP

0,37 0,5
0,55 0,75
0,75
1
1,1
1,5
1,5
2
INDICATIVE
2,2
3

QSC

F / 450 V

4,50
20
6,23
25
7,41
35
9,34
40
12,2
50
DI
ABBINAMENTO
17,1
50

QSCS

036
056
076
116
156
MOTORE
226

036
056
076
116
-156
QUADRO
226

For different voltages, please contact our sales network.

4OSM-2p60-en_b_tc

MOTOR TYPE

RATED

CURRENT

4OS - 4"

POWER

AT S.F.

THREE-PHASE

PANEL TYPE

380 V
kW

HP

0,37 0,5
0,55 0,75
0,75
1
1,1
1,5
1,5
2
2,2
3
3
4
4
5,5
5,5
7,5
7,5
10

QTD/

1,83
2,31
3,01
3,77
4,85
6,69
8,35
10,2
14,1
21,2

05-07
05-07
07-15
07-15
15-22
22-40
22-40
40-75
40-75
-

Q3D/

Q3I/

Q3A/

*Q3Y/

Q3SF/

05-07
05-07
07-15
07-15
15-22
22-40
22-40
40-75 40-75 40-75 40-75
40-75 40-75 40-75 40-75
92-110 92-110 92-110 92-110

PUMP - PANEL COMBINATION TABLES SINGLE PHASE

For different voltages, please contact our sales network.

75
75
150

4OST-2p60-en_b_tc

* require 6-wire suitable motor

MOTOR TYPE

RATED

CURRENT

L4C - 4"

POWER

AT S.F.

SINGLE PHASE

PANEL TYPE

CAPACITOR

220-230 V
kW

HP

0,37 0,5
0,55 0,75
0,75
1
1,1
1,5
1,5
2
2,2
3
3,7
5

F / 450 V

QSC/

QSCS/

5,5
7,4
8,9
12,7
13,1
17,6
30,7

20
25
35
40
50
50
75

036
056A
076
116A
156
226
406

036
056A
076
116A
156
226
(1)

PUMP - PANEL COMBINATION TABLES three phase

(1) Available on request

L4cm-2p60_c_tc

For different voltages please contact our sales network

MOTOR TYPE

RATED

CURRENT

L4C - 4"

POWER

AT S.F.

THREE PHASE

PANEL TYPE

380 V
kW

HP

0,37 0,5
0,55 0,75
0,75
1
1,1
1,5
1,5
2
2,2
3
3
4
4
5,5
5,5
7,5
7,5
10

QTD/

Q3D/

Q3I/

Q3A/

*Q3Y/

Q3SF/

2,3
2,9
3,4
4,7
5,9
7,2
9,5
11,6
15,7
20

05-07
07-15
07-15
15-22
15-22
22-40
22-40
40-75
40-75
-

05-07
07-15
07-15
15-22
15-22
22-40
22-40
40-75
40-75
92-110

40-75
40-75
92-110

40-75
40-75
92-110

40-75
40-75
92-110

75
75
75
150

For different voltages please contact our sales network

L4ct-2p60_b_tc

* Require 6-wire suitable motor

52

Lowara
L6C - L6W MOTOR SERIES
MOTOR - PANEL COMBINATION TABLE
MOTOR - CONTROL P
ANEL COMBINA
TION T
ABLE
PANEL
COMBINATION
TABLE
MOTOR TYPE

RATED

CURRENT

L6C - 6"

POWER

AT S.F.

THREE-PHASE

PANEL TYPE

380 V
kW

HP

4
5,5
5,5
7,5
7,5
10
9,3 12,5
11
15
15
20
18,5 25
22
30
30
40
37
50

QTD/

Q3D/

*Q3Y/

Q3I/

Q3A/

Q3SF/

11,5
16,1
20
25
28,2
37,3
48,4
60,2
75
90

40-75
75-92
-

40-75
75-92
92-110
110-150
110-150
150-185
185-220
220-300
-

40-75
75-92
92-110
110-150
110-150
150-185
185-220
220-300
370-450
450-550

40-75
75-92
92-110
110-150
110-150
150-185
185-220
220-300
370-450
450-550

40-75
75-92
92-110
110-150
110-150
150-185
185-220
220-300
370-450
450-550

75
75
150
150
150
220
300
370
450
550

TABELLE INDICATIVE DI ABBINAMENTO MOTORE - QUADRO

For different voltages please contact our sales network

L6c-2p60_b_tc

* require 6-wire suitable motor

MOTOR TYPE

RATED

CURRENT

L6W - 6"

POWER

AT S.F.

THREE-PHASE

MOTOR TYPE
L6W HT - 6"
THREE-PHASE

PANEL TYPE

380 V
kW

HP

QTD/

Q3D/

Q3I/

Q3A/

Q3Y/

Q3SF/

4
5,5
7,5
9,3
11
13
15
18,5
22
26
30
37
4
5,5
7,5
9,3
11
13
15
18,5
22
26
30

5,5
7,5
10
12,5
15
17,5
20
25
30
35
40
50
5,5
7,5
10
12,5
15
17,5
20
25
30
35
40

11,2
15,1
19,4
23,8
27,8
32,9
36,6
45,1
53,8
66,5
72,6
95,9
12,3
15,5
20,2
24,2
28,9
34,1
38,3
46,3
58,6
64,8
82,1

40-75
40-75
75-92
40-75
40-75
92-110
-

40-75
40-75
75-92
92-110
110-150
150-185
150-185
185-220
220-300
300-370
300-370
40-75
40-75
92-110
92-110
110-150
150-185
150-185
185-220
220-300
300-370
370-450

40-75
40-75
75-92
92-110
110-150
150-185
150-185
185-220
220-300
300-370
300-370
450-550
40-75
40-75
92-110
92-110
110-150
150-185
150-185
185-220
220-300
300-370
370-450

40-75
40-75
75-92
92-110
110-150
150-185
150-185
185-220
220-300
300-370
300-370
450-550
40-75
40-75
92-110
92-110
110-150
150-185
150-185
185-220
220-300
300-370
370-450

40-75
40-75
75-92
92-110
110-150
150-185
150-185
185-220
220-300
300-370
300-370
450-550
40-75
40-75
92-110
92-110
110-150
150-185
150-185
185-220
220-300
300-370
370-450

75
75
150
150
150
220
220
300
300
370
370
550
75
75
150
150
150
220
220
300
300
370
450

For different voltages, please contact our sales network.

L6w-2p60_b_tc

53

Lowara
L8W - L10W - L12W MOTOR SERIES
TABELLA ABBINAMENTO POMPA-QUADRO COMANDO
MOTOR - CONTROL P
ANEL COMBINA
TION T
ABLE
PANEL
COMBINATION
TABLE
MOTOR TYPE

RATED

CURRENT

L8W - 8"

POWER

AT S.F.

THREE-PHASE

MOTOR TYPE
L8W HT - 8"
THREE-PHASE

PANEL TYPE

380 V
kW

HP

Q3I/

Q3A/

Q3SF/

30
37
45
52
55
60
67
75
83
93
30
37
45
52
55
60
67
75
83

40
50
60
70
75
80
90
100
110
125
40
50
60
70
75
80
90
100
110

78,0
96,1
114
134
139
149
168
187
206
231
78,7
92,0
107
129
136
149
166
185
197

370-450
450-550
550-750
550-750
750-900
750-900
750-900
900-1100
900-1100
1100-1320
370-450
450-550
450-550
550-750
550-750
750-900
750-900
900-1100
900-1100

370-450
450-550
550-750
550-750
750-900
750-900
750-900
900-1100
900-1100
1100-1320
370-450
450-550
450-550
550-750
550-750
750-900
750-900
900-1100
900-1100

450
550
590
750
750
900
900
1100
1100
1100
450
550
590
750
750
900
900
900
1100

TABELLA ABBINAMENTO POMPA-QUADRO COMANDO

For different voltages, please contact our sales network.

MOTOR TYPE

RATED

CURRENT

L10W - 10"

POWER

AT S.F.

THREE-PHASE

MOTOR TYPE
L10W HT - 10"
THREE-PHASE

L8w-2p60_c_tc

PANEL TYPE

380 V
kW

HP

Q3I/

Q3A/

Q3SF/

93
110
130
150
83
93
110
130

125
150
175
200
110
125
150
175

228
316
329
379
202
236
281
330

1100-1320
1600-2000
1600-2000
1600-2000
900-1100
1320-1600
1320-1600
1600-2000

1100-1320
1600-2000
1600-2000
1600-2000
900-1100
1320-1600
1320-1600
1600-2000

1100
(1)
(1)
(1)
1100
1100
(1)
(1)

(1) On request.

L10w-2p60_c_tc

TABELLA ABBINAMENTO POMPA-QUADRO COMANDO

For different voltages, please contact our sales network.

MOTOR TYPE

RATED

CURRENT

L12W - 12"

POWER

AT S.F.

THREE-PHASE

MOTOR TYPE
L12W HT - 12"
THREE-PHASE

PANEL TYPE

380 V
kW

HP

Q3I/

Q3A/

Q3SF/

185
220
260
300
150
185
220
260

250
300
350
400
200
250
300
350

445
536
622
713
363
442
514
611

2000-2500
2500-3150
(1)
(1)
1600-2000
2000-2500
2500-3150
(1)

2000-2500
2500-3150
(1)
(1)
1600-2000
2000-2500
2500-3150
(1)

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

(1) On request.

L12w-2p60_c_tc

For different voltages, please contact our sales network.

54

Lowara
Single-phase
Electric
Panel

APPLICA
TIONS
APPLICATIONS

QSC Series
(60 Hz)

SPECIFICA
TIONS
SPECIFICATIONS

Protection and control of a single-phase submersible electric


pump for 4 wells.

Main switch for manual control.


Supply voltage:
1 x 230 V 10%.
Frequency: 60 Hz.
Power: 0,37 to 4 kW.
Direct motor start.
Protection class: IP55.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Plastic enclosure.
Incorporated capacitor.
Main switch with thermal protection.

OPTIONAL
ACCES
SORIES
ACCESSORIES

DPF single-phase module for


overvoltage protection (lightning
protector).

SERIE QSC..6
MODEL

RATED

RATED

RATED

VOLTAGE

POWER

CURRENT

DIMENSIONS
A

WEIGHT

CAPACITOR

kW

HP

mm

mm

mm

Kg

F/450V

QSC/036

1 x 230 V 10 %

0,37

0,5

6,3

280

220

160

20

QSC/056

1 x 230 V 10 %

0,55

0,75

6,3

280

220

160

25

QSC/056A

1 x 230 V 10 %

0,75

6,3

10

280

220

160

25

QSC/076

1 x 230 V 10 %

0,75

6,3

10

280

220

160

35

QSC/116

1 x 230 V 10 %

1,1

1,5

6,3

10

280

220

160

40

QSC/116A

1 x 230 V 10 %

1,5

10

16

280

220

160

40

QSC/156

1 x 230 V 10 %

1,5

10

16

280

220

160

50

QSC/226

1 x 230 V 10 %

2,2

16

20

280

220

160

50

QSC/406

1 x 230 V 10 %

5,5

25

32

280

220

160

75
CB-QSC6-en_a_te

55

Lowara
Single-phase
Electric
Panel

APPLICA
TIONS
APPLICATIONS

QSC
S Series
QSCS
(60 Hz)

SPECIFICA
TIONS
SPECIFICATIONS

Protection and control of a single-phase submersible electric


pump for 4 wells.

Automatic control through an


external enable contact.
Supply voltage:
1 x 230 V 10%.
Frequency: 60 Hz.
Power: 0,37 to 2,2 kW.
Direct motor start.
Protection class: IP55.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Plastic enclosure.
Incorporated capacitor.

Main switch with thermal protection.


Dry running control with float or
minimum pressure switch (available
separately).

OPTIONAL
ACCES
SORIES
ACCESSORIES

DPF single-phase module for


overvoltage protection (lightning
protector).
SLD series 24 V level kit.
Probe module for protection against
dry running (set of three electrodes
included in the supply).

SERIE QSCS..6
MODEL

RATED

RATED

RATED

VOLTAGE

POWER

CURRENT

mm

mm

mm

HP

DIMENSIONS

WEIGHT

CAPACITOR

Kg

F/450V

kW

QSCS/036

1 x 230 V 10 %

0,37

0,5

6,3

280

370

160

20

QSCS/056

1 x 230 V 10 %

0,55

0,75

6,3

280

370

160

25

QSCS/056A

1 x 230 V 10 %

0,75

6,3

10

280

370

160

25

QSCS/076

1 x 230 V 10 %

0,75

6,3

10

280

370

160

35

QSCS/116

1 x 230 V 10 %

1,1

1,5

6,3

10

280

370

160

40

QSCS/116A

1 x 230 V 10 %

1,5

10

16

280

370

160

40

QSCS/156

1 x 230 V 10 %

1,5

10

16

280

370

160

50

QSCS/226

1 x 230 V 10 %

2,2

16

20

280

370

160

50
CB-QSCS6-en_a_te

56

Lowara
Three-phase
Electric
Panel

APPLICA
TIONS
APPLICATIONS

QTD Series

SPECIFICA
TIONS
SPECIFICATIONS

Protection and control of a three-phase surface or


submersible electric pump.

Control through an external


enable contact.
Supply voltage:
3 x 400 V 10%.
Frequency: 50/60 Hz.
Power: 0,25 to 9,2 kW.
Direct motor start.
Short-circuit and overload protection.
Protection class: IP54.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Metal enclosure.
Ready for installation of dry
running control float or pressure
switch (to be ordered separately).
Power and thermal overload
indicator lights.

OPTIONAL
ACCES
SORIES
ACCESSORIES

VR3 three-phase module for


overvoltage protection (lightning
protector).
SLD series 24 V level kit.
Probe module for protection against
dry running (set of three electrodes
included in the supply).

SELECTION

For a suitable choice of control panel,


be sure the electrical input of the
motor (Ampere) is included in the
rated current value mentioned in the
table below.

0
1

LINEA
POWER

TERMICO
OVERLOAD

SERIE QTD
MODEL

RATED

RATED

RATED

VOLTAGE

POWER

CURRENT

DIMENSIONS
A

WEIGHT
C

kW

HP

QTD/02-03

3 x 400 V 10 %

0,25-0,37

0,33-0,50

mm

mm

mm

Kg

0,63

235

265

150

5,8

QTD/03-05

3 x 400 V 10 %

0,37-0,55

QTD/05-07

3 x 400 V 10 %

0,55-0,75

0,55-0,75

1,6

235

265

150

5,8

0,75-1

1,6

2,5

235

265

150

QTD/07-15

3 x 400 V 10 %

0,75-1,5

5,8

1-2

2,5

235

265

150

5,8

QTD/15-22

3 x 400 V 10 %

1,5-2,2

2-3

6,3

235

265

150

5,8

QTD/22-40

3 x 400 V 10 %

2,2-4

3-5,5

6,3

10

235

265

150

5,8

QTD/40-75

3 x 400 V 10 %

4-7,5

5,5-10

10

16

235

265

150

5,8

QTD/75-92

3 x 400 V 10 %

7,5-9,2

10-12,5

16

20

235

265

150

5,8
CB-QTD-en_c_te

57

Lowara
Three-phase
Electric
Panel

APPLICA
TIONS
APPLICATIONS

Q3D Series

SPECIFICA
TIONS
SPECIFICATIONS

Protection and control of a three-phase surface or


submersible electric pump.

Ready for installation of dry running


control float or pressure switch
(to be ordered separately).
Can be equipped with electronic
protection module with electrodes.

Manual control through an


Auto/Man selector switch.
Automatic control through an
external enable contact.
Supply voltage:
3 x 400 V 10%.
Frequency: 50/60 Hz.
24 V AC low voltage auxiliary circuit.
Power: 0,25 to 37 kW.
Direct motor start.
Short-circuit and overload protection.
Protection class: IP54.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Metal enclosure.
Power, pump running, thermal
overload and dry running indicator
lights.

OPTIONAL
ACCES
SORIES
ACCESSORIES

SLD series 24 V level kit.


Probe module for protection against
dry running (set of three electrodes
included in the supply).
Float.
Pressure switch.
VR3/SCA3 three-phase module for
overvoltage protection (lightning
protector).
A

500
300

200
150

L2-L3
L1-L2

L3-L1

50

25

M 0

SERIE Q3D
MODEL

RATED

RATED

RATED

VOLTAGE

POWER

CURRENT

kW

HP

Q3D/02-03

3 x 400 V 10 %

0,25-0,37

0,33-0,50

Q3D/03-05

3 x 400 V 10 %

0,37-0,55

Q3D/05-07

3 x 400 V 10 %

0,55-0,75

Q3D/07-15

3 x 400 V 10 %

0,75-1,5

Q3D/15-22

3 x 400 V 10 %

1,5-2,2

Q3D/22-40

3 x 400 V 10 %

2,2-4

Q3D/40-75

3 x 400 V 10 %

4-7,5

Q3D/75-92

3 x 400 V 10 %

7,5-9,2

Q3D/92-110

3 x 400 V 10 %

9,2-11

Q3D/110-150

3 x 400 V 10 %

Q3D/150-185
Q3D/185-220

DIMENSIONS
A

WEIGHT
C

mm

mm

mm

Kg

0,63

300

400

200

15

0,5-0,75

1,6

300

400

200

15

0,75-1

1,6

2,5

300

400

200

15

1-2

2,5

300

400

200

15

2-3

6,3

300

400

200

15

3-5,5

6,3

10

300

400

200

15

5,5-10

10

16

300

400

200

15

10-12,5

16

20

300

400

200

15

12,5-15

20

25

300

400

200

20

11-15

15-20

22

32

400

500

200

20

3 x 400 V 10 %

15-18,5

20-25

28

40

400

500

200

20

3 x 400 V 10 %

18,5-22

25-30

36

50

400

600

200

27

Q3D/220-300

3 x 400 V 10 %

22-30

30-40

45

63

400

600

200

27

Q3D/300-370

3 x 400 V 10 %

30-37

40-50

57

75

400

600

200

27
CB-Q3D-en_a_te

58

Lowara
Three-phase
Electric
Panel

APPLICA
TIONS
APPLICATIONS

Protection and control of a three-phase surface or


submersible electric pump.

SPECIFICA
TIONS
SPECIFICATIONS

Ready for installation of dry running


control float or pressure switch
(to be ordered separately).
Can be equipped with electronic
protection module with electrodes.

Manual control through an


Auto/Man selector switch.
Automatic control through an
external enable contact.
Supply voltage:
3 x 400 V 10%.
Frequency: 50/60 Hz.
24 V AC low voltage auxiliary circuit.
Power: 4 to 315 kW.
Star-delta starting.
Short-circuit and overload protection.
Protection class: IP54.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Metal enclosure.
Power, pump running, thermal
overload and dry running indicator
lights.

Q3Y Series

OPTIONAL
ACCES
SORIES
ACCESSORIES

SLD series 24 V level kit.


Probe module for protection against
dry running (set of three electrodes
included in the supply).
Float.
Pressure switch.
VR3/SCA3 three-phase module for
overvoltage protection (lightning
protector).
A

500
300

200
150

L2-L3
L1-L2

L3-L1

50

25

M 0

SERIE Q3Y
MODEL

RATED

RATED

RATED

VOLTAGE

POWER

CURRENT

DIMENSIONS

WEIGHT
C

kW

HP

Q3Y/40-75

3 x 400 V 10 %

4-7,5

5,5-10

Q3Y/75-92

3 x 400 V 10 %

7,5-9,2

10-12,5

16

20

400

600

200

23

Q3Y/92-110

3 x 400 V 10 %

9,2-11

12,5-15

20

25

400

600

200

23

Q3Y/110-150

3 x 400 V 10 %

11-15

15-20

22

32

400

600

200

23

Q3Y/150-185

3 x 400 V 10 %

15-18,5

20-25

28

40

400

600

200

23

Q3Y/185-220

3 x 400 V 10 %

18,5-22

25-30

36

50

500

700

200

32

Q3Y/220-300

3 x 400 V 10 %

22-30

30-40

45

63

500

700

200

32

Q3Y/300-370

3 x 400 V 10 %

30-37

40-50

57

75

600

800

250

68

Q3Y/370-450

3 x 400 V 10 %

37-45

50-60

70

90

600

800

250

80

Q3Y/450-550

3 x 400 V 10 %

45-55

60-75

80

108

600

800

250

80

Q3Y/550-750

3 x 400 V 10 %

55-75

75-100

105

138

600

800

250

109

10

16

mm

mm

mm

Kg

400

600

200

23

Q3Y/750-900

3 x 400 V 10 %

75-90

100-125

138

185

600p

1300p

300p

109

Q3Y/900-1100

3 x 400 V 10 %

90-110

125-150

175

210

600p

1500p

300p

120

Q3Y/1100-1320

3 x 400 V 10 %

110-132

150-180

210

260

800p

1700p

400p

130

Q3Y/1320-1600

3 x 400 V 10 %

132-160

180-218

250

305

800p

1700p

400p

130

Q3Y/1600-2000

3 x 400 V 10 %

160-200

218-273

290

400

800p

1900p

400p

140

Q3Y/2000-2500

3 x 400 V 10 %

200-250

273-340

400

460

1000p

1900p

400p

180

Q3Y/2500-3150

3 x 400 V 10 %

250-315

340-430

450

580

1000p

1900p

400p

Dimensions note : P indicates floor mounted control panel.

180
CB-Q3Y-en_b_te

59

Lowara
Three-phase
Electric
Panel

APPLICA
TIONS
APPLICATIONS

Protection and control of a three-phase surface or


submersible electric pump.

SPECIFICA
TIONS
SPECIFICATIONS

Ready for installation of dry running


control float or pressure switch
(to be ordered separately).
Can be equipped with electronic
protection module with electrodes.

Manual control through an


Auto/Man selector switch.
Automatic control through an
external enable contact.
Supply voltage:
3 x 400 V 10%.
Frequency: 50/60 Hz.
24 V AC low voltage auxiliary circuit.
Power: 4 to 315 kW.
Impedance start.
Short-circuit and overload protection.
Protection class: IP54.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Metal enclosure.
Power, pump running, thermal
overload and dry running indicator
lights.

Q3I Series

OPTIONAL
ACCES
SORIES
ACCESSORIES

SLD series 24 V level kit.


Probe module for protection against
dry running (set of three electrodes
included in the supply).
Float.
Pressure switch.
VR3/SCA3 three-phase module for
overvoltage protection (lightning
protector).
A

500
300

200
150

L2-L3
L1-L2

L3-L1

50

25

M 0

SERIE Q3I
MODEL

RATED

RATED

RATED

VOLTAGE

POWER

CURRENT

DIMENSIONS

WEIGHT
C

kW

HP

3 x 400 V 10 %

4-7,5

5,5-10

Q3I/75-92

3 x 400 V 10 %

7,5-9,2

10-12,5

16

20

400

600

250

35

Q3I/92-110

3 x 400 V 10 %

9,2-11

12,5-15

20

25

400

600

250

35

Q3I/110-150

3 x 400 V 10 %

11-15

15-20

22

32

500

700

250

50

Q3I/150-185

3 x 400 V 10 %

15-18,5

20-25

28

40

500

700

250

50

Q3I/185-220

3 x 400 V 10 %

18,5-22

25-30

36

50

500

700

250

50

Q3I/220-300

3 x 400 V 10 %

22-30

30-40

45

63

500

700

250

65

Q3I/300-370

3 x 400 V 10 %

30-37

40-50

57

75

500

700

250

65

Q3I/370-450

3 x 400 V 10 %

37-45

50-60

70

90

600

900

250

65

Q3I/450-550

3 x 400 V 10 %

45-55

60-75

80

108

600p

1300p

300p

100

Q3I/550-750

3 x 400 V 10 %

55-75

75-100

105

138

600p

1300p

300p

100

Q3I/750-900

3 x 400 V 10 %

75-90

100-125

138

185

600p

1500p

300p

100

Q3I/40-75

10

16

mm

mm

mm

Kg

400

600

250

35

Q3I/900-1100

3 x 400 V 10 %

90-110

125-150

175

210

600p

1500p

300p

100

Q3I/1100-1320

3 x 400 V 10 %

110-132

150-180

210

260

800p

1700p

400p

150

Q3I/1320-1600

3 x 400 V 10 %

132-160

180-218

250

305

800p

1700p

400p

150

Q3I/1600-2000

3 x 400 V 10 %

160-200

218-273

290

400

800p

1900p

400p

160

Q3I/2000-2500

3 x 400 V 10 %

200-250

273-340

400

460

1000p

1900p

400p

180

Q3I/2500-3150

3 x 400 V 10 %

250-315

340-430

450

580

1000p

1900p

400p

Dimensions note : P indicates floor mounted control panel.

200
CB-Q3I-en_b_te

60

Lowara
Three-phase
Electric
Panel

APPLICA
TIONS
APPLICATIONS

Protection and control of a three-phase surface or


submersible electric pump.

SPECIFICA
TIONS
SPECIFICATIONS

Ready for installation of dry running


control float or pressure switch
(to be ordered separately).
Can be equipped with electronic
protection module with electrodes.

Manual control through an


Auto/Man selector switch.
Automatic control through an
external enable contact.
Supply voltage:
3 x 400 V 10%.
Frequency: 50/60 Hz.
24 V AC low voltage auxiliary circuit.
Power: 4 to 315 kW.
Starting autotransformer.
Short-circuit and overload protection.
Protection class: IP54.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Metal enclosure.
Power, pump running, thermal
overload and dry running indicator
lights.

Q3A Series

OPTIONAL
ACCES
SORIES
ACCESSORIES

SLD series 24 V level kit.


Probe module for protection against
dry running (set of three electrodes
included in the supply).
Float.
Pressure switch.
VR3/SCA3 three-phase module for
overvoltage protection (lightning
protector).
A

500
300

200
150

L2-L3
L1-L2

L3-L1

50

25

M 0

SERIE Q3A
MODEL

RATED

RATED

RATED

VOLTAGE

POWER

CURRENT

DIMENSIONS

WEUGHT
C

kW

HP

Q3A/40-75

3 x 400 V 10 %

4-7,5

5,5-10

Q3A/75-92

3 x 400 V 10 %

7,5-9,2

10-12,5

16

20

500

700

250

50

Q3A/92-110

3 x 400 V 10 %

9,2-11

12,5-15

20

25

500

700

250

50

Q3A/110-150

3 x 400 V 10 %

11-15

15-20

22

32

500

700

250

50

Q3A/150-185

3 x 400 V 10 %

15-18,5

20-25

28

40

500

700

250

50

Q3A/185-220

3 x 400 V 10 %

18,5-22

25-30

36

50

500

700

250

50

Q3A/220-300

3 x 400 V 10 %

22-30

30-40

45

63

600

900

300

80

Q3A/300-370

3 x 400 V 10 %

30-37

40-50

57

75

600

900

300

80

Q3A/370-450

3 x 400 V 10 %

37-45

50-60

70

90

600p

1300p

300p

90

Q3A/450-550

3 x 400 V 10 %

45-55

60-75

80

108

600p

1500p

300p

120

Q3A/550-750

3 x 400 V 10 %

55-75

75-100

105

138

600p

1500p

300p

120

Q3A/750-900

3 x 400 V 10 %

75-90

100-125

138

185

600p

1700p

400p

150

10

16

mm

mm

mm

Kg

500

700

250

50

Q3A/900-1100

3 x 400 V 10 %

90-110

125-150

175

210

600p

1700p

400p

150

Q3A/1100-1320

3 x 400 V 10 %

110-132

150-180

210

260

800p

1900p

400p

200

Q3A/1320-1600

3 x 400 V 10 %

132-160

180-218

250

305

800p

1900p

400p

200

Q3A/1600-2000

3 x 400 V 10 %

160-200

218-273

290

400

800p

1900p

400p

230

Q3A/2000-2500

3 x 400 V 10 %

200-250

273-340

400

460

1000p

1900p

400p

230

Q3A/2500-3150

3 x 400 V 10 %

250-315

340-430

450

580

1000p

1900p

400p

250

Dimensions note : P indicates floor mounted control panel.

CB-Q3A-en_b_te

61

Lowara
Three-phase
Electric
Panel

APPLICA
TIONS
APPLICATIONS

Protection and control of a three-phase surface or


submersible electric pump.

SPECIFICA
TIONS
SPECIFICATIONS

Manual control through an


Auto/Man selector switch.
Automatic control through an
external enable contact.
Supply voltage:
3 x 400 V 10%.
Frequency: 50/60 Hz.
24 V AC low voltage auxiliary circuit.
Power: 5,5 to 110 kW.
Softstart with torque control.
Protection class: IP54.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Metal enclosure.
Dry running indicator light.
Power - pump running - malfunction
LEDs on starter keypanel.
ON/OFF selector switch for activation
of by-pass contactor.
Ready for installation of dry running
control float or pressure switch
(to be ordered separately).
Can be equipped with electronic
protection module with electrodes.

Q3SF Series

Protections against phase failure /


phase sequence / frequency out of
limits on power supply line.
Low-voltage protection on auxiliary
circuits.
Protection against starter
overtemperature / overload /
malfunction.
Protection against overload / locked
rotor / current asymmetry on motor
side.
Short-circuit protection on inputs
and outputs.
RS232 interface for remote control
and RS485 for use of remote
keypanel.
Incorporated by-pass contactor.

OPTIONAL
ACCES
SORIES
ACCESSORIES

SLD series 24 V level kit.


Probe module for protection against
dry running (set of three electrodes
included in the supply).
Float.
Pressure switch.
VR3/SCA3 three-phase module for
overvoltage protection (lightning
protector).
A

ST
ATIC ST
ARTER
STA
STARTER
CHARACTERISTIC
S
CHARACTERISTICS
Static starter for gradual start-up/
shutdown, featuring:
keypanel with liquid crystal display
showing voltage, absorbed current,
cos , operating hours, number of
starts, last twenty messages on
system status (events / alarms).

M 0

SERIE Q3SF
MODEL

RATED

RATED

RATED

VOLTAGE

POWER

CURRENT

DIMENSIONS

WEIGHT
C

kW

HP

Q3SF 75

3 x 400 V 10 %

5,5 - 7,5

7,5 -10

Q3SF 150

3 x 400 V 10 %

9,2 - 15

12,5 - 20

15

30

500

700

250

40

Q3SF 220

3 x 400 V 10 %

18,5 - 22

25 - 30

28

45

500

700

250

40

Q3SF 300

3 x 400 V 10 %

30

40

42

60

600

900

300

90

Q3SF 370

3 x 400 V 10 %

37

50

55

75

600

900

300

90

Q3SF 450

3 x 400 V 10 %

45

60

70

85

600

900

300

90

Q3SF 550

3 x 400 V 10 %

55

75

80

110

600

900

300

90

Q3SF 590

3 x 400 V 10 %

59

80

105

125

600

900

300

90

Q3SF 750

3 x 400 V 10 %

75

100

120

142

600p

1700p

400p

120

Q3SF 900

3 x 400 V 10 %

90

125

135

190

600p

1700p

400p

120

Q3SF 1100

3 x 400 V 10 %

110

150

185

245

600p

1700p

400p

120

8,5

Dimensions note : P indicates floor mounted control panel.

17

mm

mm

mm

Kg

400

600

250

35

CB-Q3SF-en_b_te

62

Lowara
Level
Control
Panel

APPLICA
TIONS
APPLICATIONS

QCL5 Series

SPECIFICA
TIONS
SPECIFICATIONS

Accessory for electric pump control panels, suitable for tank


filling or drainage applications or for activation of audible
or visual alarms.

Automatic control through probes.


Supply voltage:
1 x 230 V 10% or 1 x 24 V 10%.
Frequency: 50/60 Hz.
Voltage to probes:
15 V AC at 0,5 mA max.
Switch contact 48 V AC at 3 A max
(250 W max).
Protection class: IP55.
Ambient temperature: -5 to +40 C
(according to EN 60439-1).
Maximum relative humidity: 50% at
+40C, provided that no condensation
occurs (according to EN 60439-1).
Wall mounted.
Plastic enclosure.
Electrodes suitable for water at a
maximum temperature of 40C.
Set of three electrodes included in
the supply.

OPTIONAL
ACCES
SORIES
ACCESSORIES

Drop cable with circular cross section.


For connection of the electrodes to the
panel
we recommend
TABELLA
CAVI the following
cross sections:
LENGHT

CABLE CROSS SECTION

mm

0
50

50
100

0,5
0,8

100

200

1,0

200

400

2,5

400

>

4,0
CB-CASEL-en_a_te

Three-pole cables can be used for short


lenghts.
Otherwise we recommend the use of
unipolar cables placed at suitable
distance from each other to prevent
the capacitive effect of the cable from
interfering with the proper operation
of the electronic module.

B
Control box

SERIE QCL5
TYPE

CONTACT

POWER SUPPLY
VOLTAGE

FREQUENCY

POWER

Hz

QCL5/24

1 x 24

50/60

QCL5/230

1 x 230

50/60

NO-C-NC

DIMENSIONS
RANGE

TYPE

WEIGHT

AxBxC

mm

Kg

48

90 x 130 x 60

0,5
CB-QCL5-en_a_te

63

Lowara
Level
Probe
Module

APPLICA
TIONS
APPLICATIONS

SLD Series

SPECIFICA
TIONS
SPECIFICATIONS

Accessory for electric panels.

OPTIONAL
ACCES
SORIES
ACCESSORIES

Electronic module forr use of probes


as protection against dry running.
Supply voltage:
1 x 24 V 10% for model SLD/24.
Frequency: 50/60 Hz.
Absorbed power: 2 VA.
Voltage to probes:
15 V AC at 0,5 mA max.
Switch contact 24 V AC at 5 A max
(250 W max).
Designed for installation on Lowara
electric panels featuring DIN bar.
Electrodes suitable for water at a
maximum temperature of 40C.

Drop cable with circular cross section.


For connection of the electrodes to the
panel
we recommend
TABELLA
CAVI the following
cross sections:
LENGHT

CABLE CROSS SECTION

mm

0
50

50
100

0,5
0,8

100

200

1,0

200

400

2,5

400

>

4,0
CB-CASEL-en_a_te

CONSTRUCTION
CHARACTERISTIC
S
CHARACTERISTICS
Module made of plastic material
with DIN bar attachment.
Cables with quick plug-in connectors.
Set of three electrodes included in
the supply.
Electrodes with nylon 6 body,
stainless steel sensitive element
brass washer and nitrile rubber seal.

Three-pole cables can be used for short


lenghts.
Otherwise we recommend the use of
unipolar cables placed at suitable
distance from each other to prevent
the capacitive effect of the cable from
interfering with the proper operation
of the electronic module.

SERIE SLD
POWER SUPPLY

TYPE

KIT SLD/24

1x24

CONTACT

MAIN

POWER

50/60 Hz

N0-C-NC

DIMENSIONS

RANGE

TYPE

WEIGHT

PANELS

AxBxC

mm

Kg

24

90 x 35 x 60

0,5

QMCS-QM-QTD-Q3D-Q3YQ3A-Q3I-Q3SF
CB-SLD-en_a_te

64

Lowara
Lightning
Protection

DPF Series

APPLICA
TIONS
APPLICATIONS

Accessory for electric panels.

SPECIFICA
TIONS
SPECIFICATIONS
Varistor for overvoltage protection of
single-phase lines. To be connected
between the phase and neutral
conductor.
Operating voltage: 460 V AC.
Maximum varistor voltage: 750 V
with 100 A peak current.

VR Series

SPECIFICA
TIONS
SPECIFICATIONS
Varistors for overvoltage protection of
three-phase lines.
To be connected between the phases
(VR3 model).
Operating voltage: 460 V AC.
Maximum varistor voltage: 750 V
with 100 A peak current.
Designed for installation on Lowara
electric panels featuring DIN bar.

SCA3 Series

SPECIFICA
TIONS
SPECIFICATIONS

Lightning arresters for overvoltage


protection of three-phase lines. To
be connected between the phases
and the heart conductor,
Operating voltage: 500 V AC.
Maximum varistor voltage: 2,5 kW
with 40 kA peak current.
Designed for installation on Lowara
electric panels featuring DIN bar.

SERIE VR
TYPE

VOLTAGE

PANELS

DPF

1 x 220-240 50/60 Hz

QSM - QMC - QMCS - QPC

KIT VR1

1 x 220-230 50/60 Hz

QM - QDRM - QDRM2

KIT VR3

3 x 400 50/60 Hz

QTD - QDR - QDR2 - Q3D

KIT SCA 3

3 x 400 50/60 Hz

Q3Y-Q3A-Q3I-Q3SF-Q3D
CB-VR-en_b_te

65

Lowara

66

Lowara

TECHNICAL
APPENDIX

67

Lowara
SUBMERSIBLE ELECTRIC PUMP INST
ALLA
TION DIAGRAM
INSTALLA
ALLATION

1 - Submersible electric pump.


2 - Delivery pipe.
3 - Drop cable.
4 - Control panel.
5 - Non-return valve.
6 - Gauge.
7 - On/off valve.
8 - Level sensors for protection
against dry running.
9 - Cable clamp.
10 - Electric pump
bleed/priming cap.
A - Distance between the clamps
that secure the drop cable
to the delivery pipe.
B - Distance from the bottom of
the well to the electric pump.

COMPONENTS REQUIRED FOR


CORRECT INST
ALLA
TION
INSTALLA
ALLATION
Control panel equipped with a main switch and thermal
relay for overload protection.
Non-return valve at 10 meters distance from the delivery
ports, plus an additional non-return valve every 3050
meters of piping.
Gauge and gate valve at well mouth.
Electronic probes or floats for protection against dry
running.

RECOMMENDA
TIONS
RECOMMENDATIONS

Secure the drop cable to the pipe every 23 meters of


piping.
Make sure the electric pump is installed at a safe
distance from the bottom of the well.
Make sure there is a minimum distance of 3 mm
between the diameter of the pump and the internal
diameter of the well.
During operation, make sure that the water circulation
speed around the motor is at least 8 cm/sec.
Make sure that the minimum dynamic level of the water
in the well is at least 1 m above the pumps delivery port.

TECHNICAL APPENDIX

68

Lowara
EXAMPLE OF INST
ALLA
TION OF A SUBMERSIBLE ELECTRIC
INSTALLA
ALLATION
PUMP CONTROLLED B
Y AN INVERTER (HYDRO
VAR)
BY
(HYDROV

1 - Submersible electric pump.


2 - Cable clamp.
3 - Motor supply electrical cable.
4 - Level sensors for protection against
dry running.
5 - Support bracket.
6 - Check valve.
7 - Gauge.
8 - Pressure transducer.
9 - Gate valve.
10 - Diaphragm tank.
11 - QLC5 level probe control panel.
12 - QHI motor filter panel, required for
cable lenghts exceeding 20 meters.
13 - Hydrovar (Inverter).
14 - Thermal magnetic circuit breaker (QHV).
15 - Delivery pipe.
16 - Electric pump bleed/priming cap.
N.B. For correct Inverter-Motor coupling,
contact our sales network.

69

TECHNICAL APPENDIX

Lowara
4OS SERIES MOTORS

4OS MOTOR SERIES


TABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE
MOTOR

RATED

TEMPERATURE

TYPE

POWER

4OS

kW

30

35

40

45

50

55

all models

0,9

0,8

0,7

0,6

4OS-derating-50-en_a_te

EXAMPLE:
A 2,2 kW 4OS motor is to be used in 50C water.
Motor power at 50 C = 2,2 x 0,7 = 1,54 kW

L4C SERIES MOTORS

L4C MOTOR SERIES


TABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE
MOTOR

RATED

TEMPERATURE

TYPE

POWER

L4C

kW

30

35

40

all models

0,95

45

50

55

0,9

0,85

0,8

L4c-derating-50-en_b_te

EXAMPLE:
A 2,2 kW L4C motor is to be used in 50C water.
Motor power at 50 C = 2,2 x 0,85 = 1,87 kW

L6C SERIES MOTORS

L6C MOTOR SERIES


TABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE
MOTOR

RATED

TEMPERATURE

TYPE

POWER

L6C

kW

35

40

45

all models

0,95

0,8

50

55

60

0,75

0,7

0,6

L6c-derating-50-en_b_te

EXAMPLE:
A 7,5 kW L6C motor is to be used in 45C water.
Motor power at 50 C = 7,5 x 0,8 = 6 kW

MOTORI SERIE L6W - L8W - L10W - L12W

L6W - L8W - L10W - L12W MOTOR SERIES


TABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE
MOTOR

RATED

TEMPERATURE

TYPE

POWER

kW

25

30

35

40

45

50

55

60

STD

all models

0,75

HT

all models

(1) Standard winding for water temperature up to 35 C.

0,85 0,75 0,65


Lw-derating-en_a_te

(2) Special winding for water temperature from 35 C to 60 C.

EXAMPLE:
A 15 kW L6W motor is to be used in 35C water.
Motor power at 35 C = 15 x 0,75 = 11,25 kW

TECHNICAL APPENDIX

70

Lowara
SELECTING CABLE CROS
S-SECTIONS FOR SUBMERSIBLE
CROSS-SECTIONS
MOTORS
To select the cross-section of power cables for submersible pumps, consult the tables shown below. In these tables,
the maximum lenghts of the power cable for each cross-section are shown for each motor and next to the various
input voltage ratings.
Therefore, to find the required cable cross-section, simply read off the maximum permitted lenghts for each crosssection next to the selected motor and required input voltage.
E.g.:
A 100 m long power cable must be matched with a 230V L4C07M236 motor.
To determine the cross-section of the cable, simply move along the row of the 230V motor until you find the maximum
lenght of 100 m or immediately above it and then read off the corresponding cross-section in that column.
In this case, between 73 and 116 metres, the second value corresponding to a 4 mm2 cable is selected.
N.B.: the tables include specific data (current and power factor) for each motor and voltage rating based on a
maximum voltage drop of 4% (HD 384.5), a maximum cable temperature of 80C, water installation similar to air
installation at a temperature of 30C.

TYPE OF CABLES

CABLE TYPES
THREE CORE FLAT
SECTION
mm

4
6
10
16
25
35
50
70
95
120
150
185
240

FOUR CORE FLAT

SINGLE CORE ROUND

FOUR CORE ROUND

Hmin

Lmin

Hmax

Lmax

Weight

Hmin

Lmin

Hmax

Lmax

Weight

Dmin

Dmax

Weight

Dmin

Dmax

Weight

mm

mm

mm

mm

kg/km

mm

mm

mm

mm

kg/km

mm

mm

kg/km

mm

mm

kg/km

8
8
8
-

19,2
19,2
19,2
-

9
9
9
-

20,8
20,8
20,8
-

250
325
535
-

8
8
8
-

25,2
25,2
25,2
-

9
9
9
-

26,8
26,8
26,8
-

395
470
710
-

6,5
7,4
8,6
9,6
11
12,5
15
17,5
20,5
22
25,2
27,6
30,6

7,5
8
10
11
13
14,5
17
19,5
22,5
24,4
28,3
31
34,5

92
118
183
251
362
497
669
901
1141
1435
1795
2156
2760

14
15,7
20,9
23,8
28,9
-

16,1
18
23,9
27,1
32,9
-

360
475
836
1145
1716
-

L-cavi-en_a_td

71

TECHNICAL APPENDIX

Lowara

4OS MONOFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EP

4OS SINGLE-PHASE, 60 Hz: SIZING OF ETHYLENE-PROPILENE


(EPR) CABLES, DOL (DIRECT ON LINE) ST
ARTING
STARTING
Cable cross section: 4G x mm2
MOTOR

RATED

RATED

TYPE

POWER

VOLTAGE

SINGLE-PHASE

Kw

HP

4OS03M236

0,37 0,5

4OS05M236

0,55 0,8

4OS07M236

0,75

4OS11M236

1,1

1,5

4OS15M236

1,5

4OS22M236

2,2

4OS03M116

0,37 0,5

4OS05M116

0,55 0,75

4OS07M116

0,75

4OS11M116

1,1

1,5

Cos

220
230
220
230
220
230
220
230
220
230
220
230
110
115
110
115
110
115
110
115

0,99
0,98
0,99
0,97
0,97
0,94
0,99
0,99
0,99
0,97
0,93
0,90
0,99
0,98
0,98
0,94
0,98
0,95
0,99
0,98

CURRENT

VOLTAGE

mm

AT S.F.

DROP

A max

4,50
4,42
6,23
6,00
7,41
7,36
9,34
9,05
12,2
11,9
17,1
17,1
9,02
8,86
12,3
12,3
14,5
14,3
18,1
17,7

1,5

2,5

10

16

25

35

23

32

42

54

75

100

127

158

Maximum lenght in metres

71

118

191

286

51

85

137

206

356

43

73

117

176

304

33

56

91

137

237

373

25

42

69

104

181

285

441

17

31

51

78

135

212

324

17

29

47

71

123

193

299

418

12

21

35

52

91

143

220

307

10

18

29

44

76

120

186

259

14

23

35

60

96

148

208

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

TECHNICAL APPENDIX

4osm-b_cavi-60_d_te

72

Lowara

4OS TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),

4OS THREE-PHASE, 60 Hz: SIZING OF ETHYLENE-PROPILENE


(EPR) CABLES, DOL (DIRECT ON LINE) ST
ARTING
STARTING
Cable cross section: 4G x mm2
MOTOR

RATED

RATED

TYPE

POWER

VOLTAGE

THREE-PHASE

Kw

HP

4OS03T236

0,37 0,5

4OS05T236

0,55 0,75

4OS07T236

0,75

4OS11T236

1,1

1,5

4OS15T236

1,5

4OS22T236

2,2

4OS30T236

4OS40T236

5,5

4OS55T236

5,5

7,5

4OS75T236

7,5

10

4OS03T386
4OS05T386
4OS07T386
4OS11T386
4OS15T386
4OS22T386
4OS30T386
4OS40T386
4OS55T386
4OS75T386

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5

0,5
0,75
1
1,5
2
3
4
5,5
7,5
10

Cos

220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
380
380
380
380
380
380
380
380
380
380

0,62
0,56
0,71
0,65
0,66
0,59
0,72
0,65
0,71
0,65
0,71
0,64
0,79
0,72
0,85
0,81
0,86
0,83
0,75
0,68
0,62
0,71
0,66
0,72
0,71
0,71
0,79
0,85
0,86
0,75

CURRENT

VOLTAGE

mm

AT S.F.

DROP

A max

3,17
3,31
4,00
4,05
5,21
5,51
6,53
6,70
8,40
8,73
11,6
12,5
14,5
14,8
17,7
17,4
24,4
23,8
36,8
38,1
1,83
2,31
3,01
3,77
4,85
6,69
8,35
10,2
14,1
21,2

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

1,5

2,5

10

16

25

35

23

32

42

54

75

100

127

158

Maximum lenght in metres

184

305

127

212

339

104

174

279

414

76

127

204

304

59

99

160

239

407

41

71

115

172

294

454

29

50

82

124

213

331

21

37

62

94

163

254

386

33

52

78

133

206

312

428

29

47

84

133

201

276

552
382
315
230
180
129
92
69
47
32

522
383
301
217
156
118
82
59

482
349
251
191
135
99

519
376
287
203
150

492
351
261

406
4ost-b_cavi-60_c_te

73

TECHNICAL APPENDIX

Lowara

L4C MONOFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EP

L4C SINGLE-PHASE, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR)


CABLES, DOL (DIRECT ON LINE) ST
ARTING
STARTING
MOTOR
TYPE

RATED
POWER

RATED

Cos

VOLTAGE

CURRENT
AT S.F.

VOLTAGE
DROP

Cable cross section: 4G x mm


mm

A max
SINGLE-PHASE

Kw

HP

L4C03M236

0,37 0,5

L4C05M236

0,55 0,75

L4C07M236

0,75

L4C11M236

1,1

1,5

L4C15M236

1,5

L4C22M236

2,2

L4C40M236

4,0

5,5

L4C03M116

0,37 0,5

L4C05M116

0,55 0,75

L4C07M116

0,75

220
230
220
230
220
230
220
230
220
230
220
230
220
230
110
115
110
115
110
115

0,93
0,89
0,89
0,84
0,93
0,89
0,88
0,84
0,98
0,97
0,96
0,96
0,93
0,92
0,93
0,89
0,89
0,84
0,93
0,89

5,3
5,5
7,0
7,4
8,5
8,9
12,2
12,7
13,1
12,8
17,6
17,1
30,7
29,7
10,6
11,0
14,0
14,8
17,0
17,8

2,5

10

16

25

35

23

32

42

54

75

100

127

158

Maximum lenght in metres

106

171

256

440

49,6 83,4

135

202

346

110

165

284

443

77

116

199

312

65

98

170

267

412

127

201

309

73

116

179

249

110

172

262

364

86

134

205

282

110

168

232

63

40

68

27,5 47,2
23

39

16,3

29

15

15,2

26

12

20

4
48,1 73,2
26

41

42,3 63,6
33

50

9,03 16,1 26,6 40,5 70,2

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

TECHNICAL APPENDIX

1,5

l4cm-cavi-60-en_b_te

74

Lowara

L4C TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),

L4C THREE-PHASE, 60 Hz: SIZING OF ETHYLENE-PROPILENE


(EPR) CABLES, DOL (DIRECT ON LINE) ST
ARTING
STARTING
MOTOR
TYPE

RATED
POWER

RATED

Cos

VOLTAGE

CURRENT
AT S.F.

VOLTAGE
DROP

Cable cross section: 4G x mm


mm

A max
THREE-PHASE

Kw

HP

L4C03T236

0,37 0,5

L4C05T236

0,55 0,75

L4C07T236

0,75

L4C11T236

1,1

1,5

L4C15T236

1,5

L4C22T236

2,2

L4C30T236

L4C40T236

5,5

L4C55T236

5,5

7,5

L4C03T386
L4C05T386
L4C07T386
L4C11T386
L4C15T386
L4C22T386
L4C30T386
L4C40T386
L4C55T386
L4C75T386

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5

0,5
0,75
1
1,5
2
3
4
5,5
7,5
10

220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
380
380
380
380
380
380
380
380
380
380

0,78
0,76
0,82
0,77
0,74
0,72
0,75
0,72
0,71
0,68
0,77
0,75
0,73
0,7
0,8
0,78
0,8
0,78
0,76
0,77
0,72
0,72
0,68
0,75
0,73
0,78
0,78
0,8

3,5
3,8
4,6
4,8
5,3
5,6
7,5
7,8
9,4
9,8
11,5
12
16,5
17,3
18,8
19,2
25,4
26
2,3
2,9
3,4
4,7
5,9
7,2
9,5
11,6
15,7
20

1,5

2,5

10

16

25

35

23

32

42

54

75

100

127

158

Maximum lenght in metres

131

218

95,8

160

257

92,9

155

249

371

63

106

171

255

52,2 88,4

143

213

363

39,5 67,7

110

165

282

438

27,4 48,4 79,8

121

207

321

20,6 36,9 61,3 93,2

161

252

380

25,6 43,6 67,3

118

185

280

359
281
255 425
184 306
154 257 413
114 191 307
86,8 147 238
65,3 112 181
45,8 80,3 132
59,3 98,9

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

458
355
272
199
151

466
343
261

385

408
l4c-cavi-60-en_b_te

75

TECHNICAL APPENDIX

Lowara

L6C TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),

L6C, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES


DOL (DIRECT ON LINE) ST
ARTING
STARTING
2

Cable cross section: 4G x mm


MOTOR

RATED

RATED

TYPE

POWER

VOLTAGE

THREE-PHASE

L6C40T236
L6C40T386
L6C40T405
L6C55T236
L6C55T386
L6C55T405
L6C75T236
L6C75T386
L6C75T405
L6C93T236
L6C93T386
L6C93T405
L6C110T236
L6C110T386
L6C110T405
L6C150T236
L6C150T386
L6C150T405
L6C185T236
L6C185T386
L6C185T405
L6C220T236
L6C220T386
L6C220T405
L6C300T386
L6C300T405
L6C370T386
L6C370T405

Kw

HP

5,5

5,5

7,5

7,5

10

9,3 12,5

11

15

15

20

18,5

25

22

30

30

40

37

50

Cos

230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
380
460
380
460

0,80
0,80
0,80
0,80
0,80
0,80
0,81
0,81
0,81
0,80
0,80
0,80
0,82
0,82
0,82
0,83
0,83
0,83
0,80
0,80
0,80
0,77
0,77
0,77
0,82
0,82
0,88
0,88

CURRENT

VOLTAGE

mm

AT S.F.

DROP

A max

19,0
11,5
9,5
26,6
16,1
13,1
33,0
20,0
16,5
41,2
25,0
20,6
46,6
28,2
23,3
61,6
37,3
30,8
80,0
48,4
40
99,6
60,2
49,8
75,0
62,0
90,0
77,0

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

TECHNICAL APPENDIX

10

16

25

35

50

70

42

54

75

100

127

158

192

246

63
179
264
43
125
189
33
98
146
25
77
116
-

96
268
394
67
189
284
52
149
221
40
118
177
33
101
151
72
109
53
83
65
-

Maximum lenght in metres

167
460

260

393

539

117
327
488
92
258
381
73
207
307
62
178
264
43
130
194
99
150
79
120
55
87
-

184
509
758
146
404
594
116
325
479
99
281
414
72
207
307
54
161
240
42
130
195
94
144
70
104

279

384

527

222

306

421

178
492

245

338

457

153
427

212

294

399

112
317
468
86
248
367
68
202
300
150
225
114
166

157
438

219

299

121
343
506
97
280
414
211
314
164
237

169
474

232

137
387

187
523

296
438
233
335

405
325
463

l6c_cavi-60-en_c_te

76

Lowara

L6C TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),

L6C, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES


/
(ST
AR / DEL
TA) ST
ARTING
/
(STAR
DELT
STARTING
Cable cross section: 4G x mm2 + 3 x mm2
MOTOR

RATED

RATED

TYPE

POWER

VOLTAGE

THREE-PHASE

L6C40T236
L6C40T386
L6C40T405
L6C55T236
L6C55T386
L6C55T405
L6C75T236
L6C75T386
L6C75T405
L6C93T236
L6C93T386
L6C93T405
L6C110T236
L6C110T386
L6C110T405
L6C150T236
L6C150T386
L6C150T405
L6C185T236
L6C185T386
L6C185T405
L6C220T236
L6C220T386
L6C220T405
L6C300T386
L6C300T405
L6C370T386
L6C370T405

Kw

HP

5,5

5,5

7,5

7,5

10

9,3 12,5

11

15

15

20

18,5

25

22

30

30

40

37

50

Cos

230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
380
460
380
460

0,80
0,80
0,80
0,80
0,80
0,80
0,81
0,81
0,81
0,80
0,80
0,80
0,82
0,82
0,82
0,83
0,83
0,83
0,80
0,80
0,80
0,77
0,77
0,77
0,82
0,82
0,88
0,88

RATED

VOLTAGE

mm

CURRENT

DROP

A max*

19,0
11,5
9,5
26,6
16,1
13,1
33,0
20,0
16,5
41,2
25,0
20,6
46,6
28,2
23,3
61,6
37,3
30,8
80,0
48,4
40
99,6
60,2
49,8
75,0
62,0
90,0
77,0

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

10

16

25

35

50

70

73

94

130

173

220

274

333

426

114
314
460
80
223
333
62
176
260
49
141
209
42
121
179
29
88
132
67
102
53
82
58
40

170
468

292

453

120
333
497
95
264
389
76
212
314
65
183
270
46
135
200
34
105
156
84
127
60
93
44
66

207

323

487

164
453

257

388

533

132
365
538
113
316
464
83
234
345
64
184
272
50
150
223
111
166
84
122

207
568

313

430

178
492

271

373

514

132
367
540
103
289
426
83
238
351
178
264
137
197

202
556

278

385

522

158
439

218

301

407

128
361
532
274
404
213
305

178
496

246

332

379
558
299
425

524

Maximum lenght in metres

418

574

l6c_cavi-SD-60_a_te

*A max is the maximum rated current of the motor

77

TECHNICAL APPENDIX

Lowara

L6W TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),

L6W
L6W,, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DOL (DIRECT ON LINE) ST
ARTING
STARTING
Cable cross section: 4G x mm2
MOTOR

RATED

TYPE

POWER

THREE-PHASE

Kw

L6W40T236
4
L6W40T386
L6W40T405
L6W55T236
L6W55T386 5,5
L6W55T405
L6W75T236
L6W75T386 7,5
L6W75T405
L6W93T236
L6W93T386 9,3
L6W93T405
L6W110T236
L6W110T386 11
L6W110T405
L6W130T236
L6W130T386 13
L6W130T405
L6W150T236
L6W150T386 15
L6W150T405
L6W185T236
L6W185T386 18,5
L6W185T405
L6W220T236
L6W220T386 22
L6W220T405
L6W260T236
L6W260T386 26
L6W260T405
L6W300T236
L6W300T386 30
L6W300T405
L6W370T386
37
L6W370T405

RATED

HP

5,5

7,5

10

12,5

15

17,5

20

25

30

35

40
50

Cos

VOLTAGE AT S.F.
V

230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
380
460

0,83
0,87
0,87
0,79
0,84
0,85
0,82
0,86
0,87
0,82
0,86
0,87
0,83
0,87
0,87
0,81
0,85
0,88
0,84
0,87
0,86
0,82
0,86
0,87
0,82
0,85
0,84
0,76
0,81
0,83
0,82
0,86
0,86
0,82
0,84

CURRENT

VOLTAGE

mm2

10

16

25

35

50

70

AT S.F.

DROP

A max

42

54

75

100

127

158

192

246

61
170
253
44
128
192
32
96
143
24
76
114
62
95
52
80
44
68
-

93
255
379
68
194
289
50
146
216
39
117
173
32
97
146
82
123
70
107
55
85
44
68
-

19,0
11,2
9,2
26,4
15,1
12,2
33,6
19,4
15,8
41,3
23,8
19,5
47,9
27,8
22,8
57,4
32,9
26,4
62,5
36,6
30,5
78,2
45,1
36,7
91,9
53,8
45,0
117
66,5
53,7
126
72,6
61,0
95,9
77,1

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

TECHNICAL APPENDIX

Maximum lenght in metres

161
438

252

382

525

120
334
497
89
253
374
71
204
301
59
172
256
48
146
217
42
127
190
101
153
83
125
66
103
55
85
-

188
521

284

390

141
396
585
113
321
472
95
271
403
79
232
343
70
203
301
54
164
245
44
136
202
110
168
94
141
68
108

216

297

411

174
489

241

333

451

147 205
414
614
124 172
354 490
524
109 153
312 433
460
86 122
253 351
376 522
71,1 102
211 295
312 433
56
81
173 243
261 363
47,2 69,7
150 212
221 310
112 160
172 244

284

386

239

325

214

293

171
489

235

144
411
601
115
338
505
100
298
433
226
343

198

159
461
141
410
594
313
471

l6w_cavi-60_b_te

78

Lowara

L6W TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),

L6W
L6W,, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
/
(ST
AR / DEL
TA) ST
ARTING
/
(STAR
DELT
STARTING
2

Cable cross section: 4G x mm + 3 x mm


MOTOR

RATED

TYPE

POWER

THREE-PHASE

Kw

L6W40T236
4
L6W40T386
L6W40T405
L6W55T236
L6W55T386 5,5
L6W55T405
L6W75T236
L6W75T386 7,5
L6W75T405
L6W93T236
L6W93T386 9,3
L6W93T405
L6W110T236
L6W110T386 11
L6W110T405
L6W130T236
L6W130T386 13
L6W130T405
L6W150T236
L6W150T386 15
L6W150T405
L6W185T236
L6W185T386 18,5
L6W185T405
L6W220T236
L6W220T386 22
L6W220T405
L6W260T236
L6W260T386 26
L6W260T405
L6W300T236
L6W300T386 30
L6W300T405
L6W370T386
37
L6W370T405

HP

5,5

7,5

10

12,5

15

17,5

20

25

30

35

40
50

RATED

Cos

VOLTAGE AT S.F.
V

230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
230
380
460
380
460

0,83
0,87
0,87
0,79
0,84
0,85
0,82
0,86
0,87
0,82
0,86
0,87
0,83
0,87
0,87
0,81
0,85
0,88
0,84
0,87
0,86
0,82
0,86
0,87
0,82
0,85
0,84
0,76
0,81
0,83
0,82
0,86
0,86
0,82
0,84

CURRENT

VOLTAGE

mm

AT S.F.

DROP

A max*

19,0
11,2
9,2
26,4
15,1
12,2
33,6
19,4
15,8
41,3
23,8
19,5
47,9
27,8
22,8
57,4
32,9
26,4
62,5
36,6
30,5
78,2
45,1
36,7
91,9
53,8
45,0
117
66,5
53,7
126
72,6
61,0
95,9
77,1

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

10

16

25

35

50

70

73

94

130

173

220

274

333

426

110
297
441
81
227
338
61
172
254
48
139
204
40
116
174
33
99
147
28
86
129
21
68
104
56
85
44
69
37
57
-

165
445

282

440

123
340
505
92
258
380
74
209
307
62
176
261
51
151
222
45
131
195
35
106
159
28
88
131
71
109
60
90
69

211
582

329

496

160
443

249

378

519

129
360
528
109
304
450
92
261
384
81
229
338
64
186
276
53
155
230
41
128
193
35
110
162
83
127

202
562

307

421

172
476

261

360

496

145
409

221

304

419

567

128
359
529
103
293
434
86
246
362
69
205
305
59
177
258
135
205

197
548

272

377

512

158
447

219

304

412

133
376
552
108
313
464
94
273
396
210
316

185
519

257

350

151
432

209

283

132
379
549
293
438

185
527

253

407

553

Maximum lenght in metres

l6w_cavi-SD-60_b_te

*A max is the maximum rated current of the motor

79

TECHNICAL APPENDIX

Lowara

L8W TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),

L8W
L8W,, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DOL (DIRECT ON LINE) ST
ARTING
STARTING
Cable cross section: 4G x mm2
MOTOR

RATED

TYPE

POWER

THREE-PHASE

L8W300T386
L8W300T405
L8W370T386
L8W370T405
L8W450T386
L8W450T405
L8W520T386
L8W520T405
L8W550T386
L8W550T405
L8W600T386
L8W600T405
L8W670T386
L8W670T405
L8W750T386
L8W750T405
L8W830T386
L8W830T405
L8W930T386
L8W930T405

Kw

HP

30

40

37

50

45

60

52

70

55

75

60

80

67

90

75

100

83

110

93

125

RATED

Cos

VOLTAGE AT S.F.
V

380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460

0,83
0,83
0,83
0,83
0,85
0,85
0,83
0,83
0,85
0,85
0,85
0,85
0,86
0,86
0,85
0,85
0,85
0,85
0,87
0,87

CURRENT VOLTAGE mm2


AT S.F.

DROP

78,0
64,4
96,1
79,4
114
94,3
134
110
139
115
149
123
168
139
187
154
206
170
231
191

10

16

25

35

50

70

95

120

150

75

100

127

158

192

246

298

346

399

Maximum lenght in metres

81
-

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

TECHNICAL APPENDIX

A max

89
136
68
105
52
82
-

142
213
110
168
87
134
112
104
95
-

201
299
158
238
127
193
106
163
99
152
90
140
118
104
-

282
418
224
335
182
273
154
232
144
219
133
202
113
173
99
154
135
114

387 485
310
460
255
379
217
324
205
306
189
284
163
247
145
220
128
196
109
169

391 478
324
479
276
409
262
389
243
362
212
316
189
284
168
254
146
221

398
339
501
323
478
301
446
263
391
235
351
211
315
184
277

442
426
398
352
516
318
465
288
421
257
377

l8w_cavi-60_b_te

80

Lowara

L8W TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),

L8W
L8W,, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
/
(ST
AR / DEL
TA) ST
ARTING
/
(STAR
DELT
STARTING
Cable cross section: 4G x mm2 + 3 x mm2
MOTOR

RATED

TYPE

POWER

THREE-PHASE

L8W300T386
L8W300T405
L8W370T386
L8W370T405
L8W450T386
L8W450T405
L8W520T386
L8W520T405
L8W550T386
L8W550T405
L8W600T386
L8W600T405
L8W670T386
L8W670T405
L8W750T386
L8W750T405
L8W830T386
L8W830T405
L8W930T386
L8W930T405

Kw

HP

30

40

37

50

45

60

52

70

55

75

60

80

67

90

75

100

83

110

93

125

RATED

Cos

VOLTAGE AT S.F.
V

380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460
380
460

0,83
0,83
0,83
0,83
0,85
0,85
0,83
0,83
0,85
0,85
0,85
0,85
0,86
0,86
0,85
0,85
0,85
0,85
0,87
0,87

CURRENT VOLTAGE mm2


AT S.F.

DROP

78,0
64,4
96,1
79,4
114
94,3
134
110
139
115
149
123
168
139
187
154
206
170
231
191

A max*

10

16

25

35

50

70

95

73

94

130

173

220

274

333

426

516

55
-

57
88
67
52
-

Maximum lenght in metres

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

105
158
81
124
64
99
83
77
70
-

169
251
134
201
107
162
90
138
84
128
77
118
64
100
89
77,6
-

260
385
208
309
169
252
143
216
134
203
124
188
106
161
94
144
82
127
69
108

361 500
290
429
237
352
203
303
191
285
177
265
152
229
136
206
121
184
103
158

403
332
491
285
422
269
399
250
372
217
324
195
292
174
261
150
227

456
391
371
345 487
302
447
272
403
244
363
213
318

430
389
352
313
458

l8w_cavi-SD-60_a_te

*A max is the maximum rated current of the motor

81

TECHNICAL APPENDIX

Lowara

L10W TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR

L10W
L10W,, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DOL (DIRECT ON LINE) ST
ARTING
STARTING
Cable cross section: 4G x mm2
MOTOR

RATED

TYPE

POWER

THREE-PHASE

L10W930T386
L10W930T405
L10W1100T386
L10W1100T405
L10W1300T386
L10W1300T405
L10W1500T386
L10W1500T405

Kw

HP

93

125

RATED

Cos

VOLTAGE AT S.F.
V

380
460
380
460
380
460
380
460

110 150
130 175
150 200

0,86
0,86
0,83
0,83
0,82
0,82
0,83
0,83

CURRENT

VOLTAGE

mm2

50

70

95

120

150

185

240

300

AT S.F.

DROP

A max

192

246

298

346

399

456

538

621

318
470
221
329
211
314
180
270

365
538
254
377
242
359
209
311

228
189
316
261
329
271
379
313

Maximum lenght in metres

117
-

112
172
-

148
225
154
147
-

187
281
127
194
121
186
156

225
336
155
234
148
224
124
190

262
390
182
273
174
261
147
223

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

l10w_cavi-60_b_te

L10W TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR

L10W
L10W,, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
/
(ST
AR / DEL
TA) ST
ARTING
/
(STAR
DELT
STARTING
Cable cross section: 4G x mm2 + 3 x mm2
MOTOR

RATED

TYPE

POWER

THREE-PHASE

L10W930T386
L10W930T405
L10W1100T386
L10W1100T405
L10W1300T386
L10W1300T405
L10W1500T386
L10W1500T405

Kw

HP

93

125

RATED

Cos

VOLTAGE AT S.F.

110 150
130 175
150 200

380
460
380
460
380
460
380
460

0,86
0,86
0,83
0,83
0,82
0,82
0,83
0,83

CURRENT

VOLTAGE

mm2

25

35

50

70

95

120

150

185

AT S.F.

DROP

A max*

220

274

333

426

516

599

691

790

405

468

288
426
276
409
236
352

332
490
318
470
274
406

228
189
316
261
329
271
379
313

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

111
-

105
161
109
105
-

153
231
104
161
99
154
127

216
323
151
229
145
220
120
185

277
411
195
293
188
282
158
239

342
506
242
361
233
347
198
296

l10w_cavi-SD-60_a_te

*A max is the maximum rated current of the motor

TECHNICAL APPENDIX

Maximum lenght in metres

82

Lowara

L12W TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR

L12W
L12W,, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DOL (DIRECT ON LINE) ST
ARTING
STARTING
Cable cross section: 4G x mm2
MOTOR

RATED

TYPE

POWER

THREE-PHASE

L12W1850T386
L12W1850T405
L12W2200T386
L12W2200T405
L12W2600T386
L12W2600T405
L12W3000T386
L12W3000T405

Kw

RATED

Cos

VOLTAGE AT S.F.

HP

380
460
380
460
380
460
380
460

185 250
220 300
260 350
300 400

0,86
0,86
0,85
0,85
0,85
0,85
0,88
0,88

CURRENT

VOLTAGE

mm2

50

70

95

120

150

185

240

300

AT S.F.

DROP

A max

192

246

298

346

399

456

538

621

151
228
120
183
153
-

177
266
142
215
181
156

445
368
536
443
622
514
713
589

Maximum lenght in metres

155
-

120
184
146
-

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

l12w_cavi-60_b_te

L12W TRIFASE, 60 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR

L12W
L12W,, 60 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
/
(ST
AR / DEL
TA) ST
ARTING
/
(STAR
DELT
STARTING
Cable cross section: 4G x mm2 + 3 x mm2
MOTOR

RATED

TYPE

POWER

THREE-PHASE

L12W1850T386
L12W1850T405
L12W2200T386
L12W2200T405
L12W2600T386
L12W2600T405
L12W3000T386
L12W3000T405

Kw

RATED

Cos

VOLTAGE AT S.F.

HP

185 250
220 300
260 350
300 400

380
460
380
460
380
460
380
460

0,86
0,86
0,85
0,85
0,85
0,85
0,88
0,88

CURRENT

VOLTAGE

mm2

50

70

95

120

150

185

240

300

AT S.F.

DROP

A max*

333

426

516

599

691

790

932

1076

148
-

280
415
228
339
193
289
167
252

322
476
263
390
224
333
197
295

445
368
536
443
622
514
713
589

Exposed cable laid at a temperature of 30C, maximum conductor temperature of 90C

Maximum lenght in metres

128
196
157
129
-

162
246
129
198
165
138

197
295
158
240
132
201
171

230
343
187
280
157
237
133
204

l12w_cavi-SD-60_a_te

*A max is the maximum rated current of the motor

83

TECHNICAL APPENDIX

Lowara
JOINT
BETWEEN DROP CABLE AND MOTOR CABLE
GIUNZIONE TRA CAVO DI DISCESA E CAVO MOTORE
MOTOR
TYPE

POWER
kW

FOUR-CORE DROP CABLE - SECTION (mm )

TYPE OF JOINT

1,5

2,5

10

16

25

35

50

70

95

GR2 GR2 GR2 GR6 GR6 GR7


GR5 GR5 GR5
Resin-filled method GR2 GR2
GR6 GR6 GR6 GR7 GR7 GR5

4OS
L4C

0,37 - 7,5 Heat-shrink method GT1 GT1 GT2 GT2 GT3 GT4 GT5 GT6
Tape method

4 - 37

POWER
kW

2,5

10

POWER
kW

16

25

35

Heat-shrink method GT1 GT1 GT2 GT2 GT3 GT4 GT5 GT6

50

70

95

120 150 185 240 300


-

2
SINGLE-CORE DROP CABLE - SECTION (mm )

TYPE OF JOINT

Resin-filled method

30 - 300 Heat-shrink method

2,5

10

16

25

35

50

70

95

120 150 185 240 300

GR1 GR1 GR1 GR3 GR3 GR3 GR3 GR3


GR1 GR1 GR1 GR1 GR1
GR4 GR4
GR3 GR3 GR3 GR4 GR4 GR4 GR4 GR4
-

Tape method

Self-vulcanizing tape + PVC tape

(1) Use self-vulcanizing sealing putty to fill in the gaps between the three-conductor cable and the ground cable in the area covered
by the final layer of tape, to restore continuity to the protective sheath.

TECHNICAL APPENDIX

Self-vulcanizing tape + PVC tape

1,5

L8W
L10W
L12W

GR2 GR2 GR2 GR6 GR6 GR7


GR5 GR5
GR6 GR6 GR6 GR7 GR7 GR5

Tape method

MOTOR
TYPE

THREE-CORE DROP CABLE - SECTION (mm2)

TYPE OF JOINT

Resin-filled method GR2 GR2 GR2


4 - 37

Self-vulcanizing tape + self-vulcanizing sealing putty and PVC tape (1)

1,5

L6C
L6W

GR2 GR2 GR2 GR6 GR6 GR7


GR5 GR5 GR5
GR6 GR6 GR6 GR7 GR7 GR5

Heat-shrink method GT1 GT1 GT2 GT2 GT3 GT4 GT5 GT6
Tape method

MOTOR
TYPE

Self-vulcanizing tape + self-vulcanizing sealing putty and PVC tape (1)

Resin-filled method GR2 GR2

L6C
L6W

120 150 185 240 300

84

L-giunzioni-en_c_te

Lowara
CALCULA
TING THE SPEED OF THE FL
UID THA
T FL
OWS
CALCULATING
FLUID
THAT
FLOWS
AROUND A SUBMERGED MOTOR AND SIZING OF THE
COOLING SLEEVE

The following formula is used to verify whether the speed of the fluid that flows around the motor of a submersible pump is high
enough to guarantee the proper cooling of the motor:

v=

Q
2
2

D2 d

(
)
4
4

Where: Q in [m3/s] is the operating flow rate of the electric pump; only half of this flow is taken into account, because the fluid
which is sucked into the area of the filter (2), comes from the motor side (3) as well as from the pump side (1);
D in [m] corresponds to the diameter of the well;
d in [m] corresponds to the diameter of the motor (3);
v in [m/s] is the calculated speed of the fluid that flows around the motor.
Now, compare the speed thus calculated (v) with the minimum speed required for correct cooling of the motor (vm): if v vm it
means that the motor is properly cooled, if v < vm will be necessary to mount a cooling sleeve (4).
Example
Example:
An electric pump OZ630/12 (motor diameter d = 0.144 m) operates in an 8" well (well diameter D = 0.203 m) with flow rate
Q = 20 m3/h = 0.0055 m3/s.
Speed of fluid v = (0.0055/2) / {[(0.203)2/4 (0.144)2/4]} = 0.17 m/s.
The minimum speed required for proper motor cooling is vm = 0.20 m/s.
Because v < vm, it will be necessary to mount a cooling sleeve.
The following formula is used to determine the maximum diameter of a cooling sleeve to be mounted on a submersible motor:

Q
d2

D = 4
+
4
v
Where: Q in [m3/s] is the operating flow rate of the electric pump; the entire flow is taken into account because the fluid comes
from the motor side (3) only;
D in [m] corresponds to the diameter of the cooling sleeve (4);
d in [m] corresponds to the diameter of the motors(3);
vm in [m/s] is the minimum speed of the fluid that flows around the motor.
If the electric pump operates at different flow rate, the minimum flow rate must be taken into account for calculating the diameter
of the cooling sleeve.
Example
Example:
A motor coupled to the electric pump OZ615/24 (motor diameter d = 0.144 m), which operates with flow rate
Q = 15 m3/h = 0.0042 m3/s, requires a minimum speed of the fluid of vm = 0.20 m/s.
Cooling sleeve diameter D = {4[(0.0042/(0.2)+(0.144)2/4] }0.5 = 0.217 m.

85

TECHNICAL APPENDIX

Lowara
ASYNCHRONOUS MOTOR ST
ARTING SYSTEMS
STARTING
Direct
Suitable for low-power motors.
The starting current (Is) is much higher than the rated
current (In).
Starting current Is = In x 4 8
Starting torque Ts = Tn x 2 3

Autotransformer
The pump is started with a voltage which is lower than
the rated one.
The Lowara panels use an autotransformer with a voltage
that is 70% the value of the line voltage.
The switch to the rated voltage occurs without any
interruptions of the power supply.
Rated voltage
Un = 400 V

Indirect
Star/Delta
The starting current (Is) is three times less than the direct
starting current.
Starting current Is = In x 1.3 2.7
Starting torque Ts = Tn x 0.7 1
In the star to delta changeover phase (approx. 70 ms) the
motor is not supplied and tends to reduce its rotation
speed.
In the case of submersible electric pumps with power
above 10 HP, the modest mass of the rotor causes a
slowdown at changeover, so that the initial Star supply
phase is rendered partially useless.
In such cases we recommend using impedance panels or
an autotransformer.

Starting current
Us

Is = In x 48 x

( )
( )

= In x 36

Un

Starting torque

Us

Ts = Tn x 23 x

= Tn x 11,5

Un

DIAGRAM OF STARTING INPUTS


Ia

Impedances
The motor is started with a voltage which is lower than
the rated one, and which is obtained by means of
impedances.
The Lowara panels use impedances which cut down to
70% the starting voltage.
The switch to the rated voltage takes place without any
interruptions of the power supply.
Rated voltage Un = 400 V
Starting voltage Us = Un x 0,7 = 280 V
Starting current

( )
Us

Is = In x 48 x

= In x 36

Un

1
2
3
4

Starting torque

( )
Us

Ts = Tn x 23 x

= Tn x 11,5

Un

TECHNICAL APPENDIX

86

=
=
=
=

Direct
Star-Delta
Impedances
Autotransformer

SPEED

Lowara
ITT Lowara part of ITT Corporation and headquarters of Residential and
Commercial Water - EMEA.
World leading in offering high reliable fluid handling solutions for Building
Services, Irrigation and Industrial applications. We provide a complete range of
high quality pumps, packaged systems and controls and are specialized in
engineering and manufacturing stainless steel products.
ITT Lowara is headquartered in Vicenza, Italy and operates in more than 80
countries across the world with own plants in Italy, Austria, Poland and Hungary.
The company has 1.300 employees and generated 2008 sales exceeding $440
million. ITT Lowara is wholly owned by the ITT Corporation of White Plains, New
York, and is the EMEA headquarter of ITTs Residential and Commercial Water
division. ITT Corporation is a high-technology engineering and manufacturing
company operating on all seven continents in three vital markets: water and fluids
management, global defense and security, motion and flow control. ITT
Corporation generated 2008 sales of $11.7 billion

ITT RESIDENTIAL AND COMMERCIAL WATER DIVISION - EMEA


Headquarters
LOWARA S.r.l. Unipersonale
Via Dott. Lombardi, 14
36075 Montecchio Maggiore
Vicenza - Italy
Tel. (+39) 0444 707111
Fax (+39) 0444 492166
e-mail: lowara.mkt@itt.com
http: //www.lowara.com
AUSTRIA
ITT AUSTRIA GmbH
A-2000 STOCKERAU
Ernst Vogel-Strae 2
Tel. (+43) 02266 604
Fax (+43) 02266 65311
e-mail: info.ittaustria@itt.com
http://www.ittaustria.com
FRANCE
LOWARA FRANCE S.A.S.
BP 57311
37073 Tours Cedex 2
Tel. (+33) 02 47 88 17 17
Fax (+33) 02 47 88 17 00
e-mail: lowarafr.info@itt.com
http://www.lowara.fr
GERMANY
ITT LOWARA DEUTSCHLAND GmbH
Biebigheimer Strae 12
D-63762 Groostheim
Tel. (+49) 0 60 26 9 43 - 0
Fax (+49) 0 60 26 9 43 - 2 10
e-mail: lowarade.info@itt.com
http://www.lowara.de

For additional addresses, please visit


www.lowara.com

cod. 191000001
191014801 PW12/09
12/09

Lowara reserves the right to make modifications


without prior notice.

IRELAND
ITT IRELAND
50 Broomhill Close
Airton Road
Tallaght
DUBLIN 24
Tel. (+353) 01 4524444
Fax (+353) 01 4524795
e-mail: lowara.ireland@itt.com http://www.lowara.ie
NEDERLAND
LOWARA NEDERLAND B.V.
Zandweistraat 22
4181 CG Waardenburg
Tel. (+31) 0418 65 50 60
Fax (+31) 0418 65 50 61
e-mail: sales.nl@itt.com
http://www.lowara.nl
POLAND
LOWARA VOGEL POLSKA Sp. z o.o.
PL 57-100 Strzelin
ul. Kazimierza Wielkiego 5
Tel. (+48) 071 769 3900 - Fax (+48) 071 769 3909
e-mail: info.lowarapl@itt.com http://www.lowara-vogel.pl

PORTUGAL
ITT PORTUGAL, Lda
Praeta da Castanheira, 38
4475-019 Barca
Tel. (+351) 22 9478550
Fax (+351) 22 9478570
e-mail: info.pt@itt.com
http://www.itt.pt
RUSSIA
LOWARA RUSSIA
Kalanchevskaya st. 11 b.2, off. 334
107078 Moscow
Tel. (+7) 495 631 55 15
Fax (+7) 495 631 59 72
info.lowararu@itt.com - www.lowara.ru
UK
LOWARA UK LTD.
Millwey Rise, Industrial Estate
Axminster - Devon EX13 5HU UK
Tel. (+44) 01297 630200
Fax (+44) 01297 630270
e-mail: lowaraukenquiries@itt.com
http://www.lowara.co.uk

Das könnte Ihnen auch gefallen