Sie sind auf Seite 1von 8

E2K-C

E2K-C

Adjustable Capacitive Prox


Cylindrical Sensor Offers Adjustable Detecting Distance
s Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic s Allows indirect detection of materials inside non-metallic containers s Adjustable detecting distance from 3 to 25 mm s Built-in amplifier accepts wide range of supply voltages and switches up to 200 mA s Mounting bracket included

E2K-C

Ordering Information
s SENSORS
Type Nominal detecting distance Output type Part AC switching type (SCR) number DC switching NPN type PNP Unshielded 3 to 25 mm (0.12 to 0.98 in), adjustable NO NC E2K-C25MY1 E2K-C25MY2 E2K-C25ME1 E2K-C25ME2 E2K-C25MF1 E2K-C25MF2

s REPLACEMENT PARTS
Description Mounting bracket for E2K-C (supplied with sensor) Part number Y92E-A34

E2K-C

E2K-C

Specifications
Part number Sensor type Body Supply voltage Current consumption Detectable object type Sensitivity Effective maximum detecting distance (with standard target) Standard target size (grounded mild steel, L x W x H) Differential travel Control output AC solidstate Type Max. load Min. load Max. off-state leakage current Max. on-state voltage drop Type Size Type E2K-C25M Capacitive 34 mm (1.34 in) diameter Unshielded 10 to 40 VDC, 10% max. permissible ripple peak to peak 10 mA max. at 12 VDC 15 mA max. at 24 VDC Metallic and non-metallic objects Adjustable 3 to 25 mm (0.12 to 0.98 in) 50 x 50 x 1 mm (2.0 x 2.0 x 0.04 in) 15% max. of detecting distance NPN-NO open collector with pull-up NPN-NC open collector with pull-up PNP-NO open collector with pull-down PNP-NC open collector with pull-down 200 mA See Residual Load Voltage graph in Engineering Data 70 Hz Not provided Provided SCR-NO (E2K-C25MY1) SCR-NC (E2K-C25MY2) 200 mA 5 mA See Leakage Current Characteristics graph in Engineering Data 2V max. E2K-C25MY

90 to 250 VAC, 50/60 Hz 1 mA max. at 100 VAC 2 mA max. at 200 VAC

DC solidstate

Max. load Max. on-state voltage drop Response frequency Output shortCircuit circuit protection DC power supply reverse polarity Weld field immunity RFI immunity Indicators Materials Housing Sensing face Cable sheath Prewired

10Hz

Not provided

Mounting Connections Weight with cable Enclosure ratings

UL NEMA IEC 144 Approvals UL CSA Ambient operating temperature Vibration Shock

Not provided Not provided Target Present (red LED) Output Operation (red LED) ABS/PC ABS PVC Bracket Y92E-A34 included Three-conductor cable, 2 m (6.56 ft) length Two-conductor cable, 2 m (6.56 ft) length Approx. 200 g (7.0 oz.) 1 1, 4, 12, 13 IP67 Listed, File Number E76675 Certified, File Number LR45951 25 to 70C (13 to 158F) 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Approx. 50 G's

E2K-C

E2K-C

Operation
s OUTPUT CIRCUIT DIAGRAMS AND TIMING CHARTS DC Switching Types
E2K-C25ME The dotted line shows a transistor circuit load.
22 4.7 K D1 Prox. switch main circuit D2 Black (White) 2.2 ZD Blue (Black) 0V Tr Brown (Red) +V

E2K-C25MF The dotted line shows a transistor circuit load.


Brown (Red) +V ZD Prox. switch main circuit Black (White) D2 22 Blue (Black) 0V 2.2 D 1 Tr

Load

4.7 K

Note: IEC colors are shown in parentheses. E2K-C25ME1 NO


Target Load (between red and white) Present Absent Operates Releases

E2K-C25ME2 NC
Target Present Absent Load (between Operates white and black) Releases Logic (between red and white) Operation indicator H L ON OFF

E2K-C25MF1 NO

Load

E2K-C25MF2 NC

Logic (between H white and black) L ON Operation indicator OFF

AC Switching Types
E2K-C25MY
White (Black) Load NO Prox. switch main circuit Black (Blue) Load NC NO NC Target Present Absent Operates Releases Operates Releases ON OFF ON OFF

Operation indicator

Note: IEC colors are shown in parentheses.

E2K-C

E2K-C

Engineering Data
Operating Range
E2K-C25MY1
Standard X target

Detecting distance X (mm)

Detecting30 head Y 25 20 15 10

Setting distance 25mm 20mm 15mm 10mm

5 5mm 25 20 15 10 5 0 5 10 15 20 25 Y (mm) Detecting head

Detecting Distance vs. Size and Material of Target


Detecting Distances of Common Materials
30

25

Detecting distance X (mm)

20

Detecting distance X (mm)

Detecting distance X

Grounded mild steel t = 1 mm Ungrounded mild steel t = 1 mm

25

20

15

15

10 Phenolic resin plate t = 6 mm

10

5 0

Soft wood (160 x 120 x 15 mm)

Grounded mild steel (50 x 50 x 1 mm)

Milk (500 ml)

Salt

Neoprene rubber (50 x 50 x 5 mm)

10

20

30 40

50

60 70 (mm)

80 90 100

Size of target

Phenolic resin (50 x 50 x 50 mm)

Glass (200 x 50 x 3 mm)

Plastic resin pellets

Sugar

Flour

E2K-C
Residual Load Voltage Characteristics
DC switching types E2K-C25M 24VDC
1 0.5 ON (V2) 100 90 80 70 60 50 40 30 Residual output voltage

E2K-C

AC switching types E2K-C25MY 100 VAC 200 VAC

Residual output voltage 200 ON

Load voltage (V)

24 VDC 0.1 0.05 OFF (V1)

Load voltage (V)

Load voltage (V)

ON

150

Load AC 100V

100

Load AC 200V OFF 5 10 50 100 200 Load current (mA)

50 OFF 10 50 100 200 Load current (mA)

0.01

50

100 150 200 Load current (mA)

250

20 Residual 10 load voltage 0 1 5

Residual load voltage

0 1

R< = P i VS

(mW) 10 i R : Power rating of bleeder resistor : Load current (mA) : Supply voltage (V)

VS

(k)

P>

VS 2

Note: When the current rating of the load is less than 10 mA, false operation may occur. This is normal, and the problem can be cured by installing a bleeder resistor in parallel with the load. Use the formulas given here to calculate the power rating and value of the resistor.

Leakage Current Characteristics


AC switching types E2K-C25MY
3.0

2.5

Leakage current (mA)

2.0

1.5

1.0

0.5 OFF state 0 0 80 100 120 140 160 180 200 220 240 260 Supply voltage (V)

Dimensions
Unit: mm (inch)

s SENSORS
E2K-C25M
82 (3.23) 31 (1.22) Cap screw for sensitivity adjustment 6 (0.24) Operation indicator (LED)

20 (0.79) 34 (1.34) dia.

0.15 (0.006)

Cable: 2 m (6.56 ft.) length

Note: Cable may be extended to 200 m (656 ft).

E2K-C
Unit: mm (inch)

E2K-C

s MOUNTING BRACKET
Y92E-A34 (supplied with sensor)
45 (1.77) 5.2 (0.20) 43 (1.69) R2.6 (0.102) 6.3 (0.25) Two elliptic holes for bracket mounting 2 (0.08) 35 (1.38) 23.5 (0.93) 15 (0.59) Two M4 sensor clamping screws Sensor mounting hole E2K-C proximity sensor

42 (1.65) 55 (2.16)

51 (2.01) 30 (1.18) 6 (0.24) 45 (1.77) 58 (2.28) Two 5.5 (0.22) dia. mounting holes 35 (1.38)

14 (0.55)

Precautions
s EFFECTS OF SURROUNDING METALS
When mounting the sensor, be sure to provide the minimum distance shown in the diagram. This prevents the sensor from being affected by metallic objects other than the target. Also, when using the supplied mounting bracket, be sure to allow a distance of 20 mm or more between the detecting face and the mounting bracket.
20 (0.79) 80 (3.15) mm min. mm min.

s MUTUAL INTERFERENCE
To prevent mutual interference, be sure to space the two sensors at a distance greater than that shown in the diagrams. Opposed mounting

Surrounding conductive object Detecting face

100 (3.94) mm min.

Parallel mounting

To ground

Metal 100 (3.94) mm min.

80 (3.15) mm min. 80 (3.15) mm min. 80 (3.15) mm min.

Surrounding conductive object

E2K-C
s SENSITIVITY ADJUSTMENT NO type (E2K-C25M1)
Remove protective rubber plug to gain access to sensitivity adjustment screw. Use the screwdriver provided with each sensor to turn the sensitivity adjustment screw.

E2K-C
s USING METAL CONDUIT
If a high voltage of power line runs near the proximity sensor cable, be sure to wire the sensor cable through a metal conduit to protect the sensor from malfunctioning or damage.

s SURGE PROTECTION
The proximity sensor is provided with a surge suppressor circuit. However, if any large surge generating source (i.e., motor, welding machine, etc.) exists in the vicinity of the proximity sensor, insert a surge suppressor (such as a varistor) into the surge generating source.

1) Remove any targets from in front of the sensor. Turn the sensitivity adjustment screw CLOCKWISE until the sensor turns ON and the indicator illuminates.
Sensitivity adjustment

Stop when the sensor turns ON

2) Place a target in front of the sensor. Turn the sensitivity adjustment screw COUNTERCLOCKWISE until the sensor turns OFF and the indicator goes out. Note the number of revolutions between OFF and ON positions.
Sensitivity adjustment

Stop when the sensor turns OFF

3) If the number of revolutions is greater than one and a half, the sensor will provide stable output. If the number of revolutions is less than one and a half, increase or decrease the distance between the target and the sensing face as necessary to allow at least one and a half revolutions between the ON and OFF positions.
1 ON point

Stable operation if the difference is more than 1.5 turns

4) Now turn the sensitivity adjustment screw CLOCKWISE to the midpoint between the ON and OFF points.
1 ON point Set at midpoint 1 between ON and OFF points 2 OFF point

5) If the distance between the target and the sensor is not constant, perform the first adjustment operation (#1) when the target is at the closest position to the sensor. Then perform the second adjustment operation (#2) when the target is at the farthest position from the sensor.

NC type (E2K-C25M2)
The sensitivity adjustment procedure for NC type proximity sensors is the same as for NO type sensors, with the exception that ON and OFF operations of the proximity sensor and ON and OFF points in the adjustment procedure are exactly reversed.

E2K-C

E2K-C

OMRON ELECTRONICS LLC


One East Commerce Drive Schaumburg, IL 60173

OMRON ON-LINE
Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci

OMRON CANADA, INC.


885 Milner Avenue Scarborough, Ontario M1B 5V8

1-800-55-OMRON
Cat. No. CEDSAX4 11/01

416-286-6465
Printed in the U.S.A.

Specifications subject to change without notice.