Elevator Rehabilitation The Way to Safety & Green Otis Elevator Company

Proprietary information, Otis Elevator Company (H.K.) Ltd

United Technologies Corporation (UTC)


Carrier Hamilton Sundstrand

Sikorsky

Otis

Pratt & Whitney

UTC Power

UTC Fire & Security

Proprietary information, Otis Elevator Company (H.K.) Ltd 2

Why Elevator Rehabilitation


Customer Needs

Rehabilitation

Time

Perceived Performance

Proprietary information, Otis Elevator Company (H.K.) Ltd 3

HK Code Evolution
No. of lifts installed in Hong Kong Design Code (2000 Version) Design Code (1993 Version) Design Code Amendments

BS5655

BS2655

1984 1958

1994

2000

Year

Proprietary information, Otis Elevator Company (H.K.) Ltd 4

Rehabilitation Needs SPACE Concept


Safety Machine/ Motor Group Control Drive System Controller Door Operator Buttons/ Indicators Cab Interiors Safety/ Statutory Performance Aesthetics Comfort Reliability Energy Savings

Proprietary information, Otis Elevator Company (H.K.) Ltd 5

Energy Efficiency Rehabilitation contributes to reduce building energy


consumption
Proprietary information, Otis Elevator Company (H.K.) Ltd 6

Elevator Energy Consumption


Elevator energy consumption is:

Transportation
Energy needed to move the car and counterweight Used by drive and machine

Controller power supply


Permanent controller consumption

Car lighting
Only if the elevators is moving

Door operation
Energy needed to open/close doors Used by door operator with VF motors

Controllers are in stand-by Only if passengers use the mode if elevators are not car used (14h/day) Otherwise use of standby Hall Buttons mode

Proprietary information, Otis Elevator Company (H.K.) Ltd 7

Innovations

Flat Belts
Steel cables Polyurethane coating
Improved traction No metal to metal contact No lubrication needed

Anti-corrosion No rope or belt twist

longer expected lifetime


10

Chemically resistant

Pulse System

Monitors variations in electrical resistance Alert to cable wear and breakage Diode indication Otis Line = Pulse + REM = remote monitoring

Safety and reliability


11

Compact Sheaves

Compact diameter Flat contact: Good pressure distribution Sealed bearings lubricated for life

Longevity and relaibility


12

2:1 Roping
Belt termination Gearless machine

Belt termination

Car top sheave

Counterweight sheave

Lower machine power


13

Compact Gearless Machine


Integrated sheave and machine shaft

Disk brake

Synchronous permanent magnet motor

Robust and reliable


14

Green Hoistway

Flat belt

Reduced diameter sheave

2:1 Roping

Compact machine

Lower energy consumption

Higher return on energy usage


15

Benefits
Respecting our environment
Environmentally friendly machine: Sealed bearings lubricated for life Flat belts with no need for lubrication Gearless with low inertia: high efficiency Economical control system: Lower electricity consumption Lower installation power Standby operation
16

Filtered against electromagnetic interference

Flat belts: 2 to 3 times longer life compared to conventional ropes Quiet operation: Low noise and vibration as belt contact is polyurethane to metal Gearless machine: Much longer installation life compared to conventional systems Pulse SystemTM: Monitors belt condition 24 hours a day, 7 days a week

17

Drives

18

ReGen drives
Counterweight helps the machine to move elevators car

50% loaded elevator car

Elevator counterweight

Proprietary information, Otis Elevator Company (H.K.) Ltd 19

ReGen drives

<
Up situations
Less than 50% loaded car going up Counterweight is heavier

>
Down situations
More than 50% loaded car down up Counterweight is lighter

Elevators machine is helped, there is an energy excess


Proprietary information, Otis Elevator Company (H.K.) Ltd 20

Non Regenerative VF drives


Resistances allow to dissipate electrical energy excess Elevators machine

Resistances

Controller with VF

Proprietary information, Otis Elevator Company (H.K.) Ltd 21

ReGen drives

Energy excess is re-directed to the controller

Energy excess is dissipated in form of heat

Standard VF cause energy losses and low efficiency


Proprietary information, Otis Elevator Company (H.K.) Ltd 22

ReGen drives
It works like a double VF

Input power supply current is modulated to feed the machine

Regenerated energy can be used in the building

Machine output power excess goes back to ReGen Drive

Electrical energy excess is remodulated to become identical as imput current

Proprietary information, Otis Elevator Company (H.K.) Ltd 23

Safety Rehabilitation reduces safety hazards and improves passenger and


tenant confidence, resulting in greater peace of mind
Proprietary information, Otis Elevator Company (H.K.) Ltd 24

Safety

Rehabilitating an elevator dramatically reduces safety hazards It also improves passenger and tenant confidence, resulting in greater peace of mind
Proprietary information, Otis Elevator Company (H.K.) Ltd 25

HK Code Evolution
No. of lifts installed in Hong Kong Design Code (2000 Version) Design Code (1993 Version) Design Code Amendments

BS5655

BS2655

1984 1958

1994

2000

Year

Proprietary information, Otis Elevator Company (H.K.) Ltd 26

Safety and Code


Multi-beam Light Ray

CCTV in Lift Car

Obstruction Switch Motor Run Time Limiter

Protection Against Uncontrolled Car Movement

Safety & Code

Car Door Mechanical Lock

Intercom

Out of Service Display in Hall Indicator

Proprietary information, Otis Elevator Company (H.K.) Ltd 27

QUESTION & ANSWER

Proprietary information, Otis Elevator Company (H.K.) Ltd 28