38HK18-70

38HK12-70
38HQ18-24
38HQ18-24
Condensing Units - 60Hz
1Cond
to 6 Nominal Tons

Product Data
The 38H Series Energy-Efficient Split condensing units incorporate innovative technology to provide
reliable cooling performance. Built into these units are features most desired by the industry.

Features/Benefits
Designed especially for high ambient
environment.
EER (Energy Efficiency Ratio) ratings
of up to 10.0.
The small footprint coupled with the
horizontal airflow design means that the
38H Series units can be installed within
200 mm (8 in). of an outside wall, on a
roof, balcony, or deck.
Electrical Range
All units are offered in 220-240v single
phase. Three-phase units are available
from 48 through 70 sizes in 220v.
Wide Range of Sizes
The 38H Series is available in 7
nominal sizes from 1.5 through 6 to
meet the needs of residential and light
commercial applications.
Application Versatility
The unit can be combined with a wide
variety of evaporator coils and blower
packages to provide quiet, dependable
comfort. Unit can be installed on a roof or
at ground level.
Easy
access
for
service
and
maintenance
A single panel provides immediate
access to the isolated compressor and
control compartment, allowing a service
technician access to check unit operation
without losing condenser airflow. Coils
can be cleaned quickly from the outside.
Secure operation
If security is an issue, outdoor and
indoor units are connected only by
refrigerant piping and wiring to prevent
intruders
from
crawling
through
ductwork. The 38H Series units can be
installed 8 in. away from outside walls,
protecting coils from vandals and severe
weather.

38HK-04 PD 60HZ 2011

38HK/HQ

Fast installation
Carriers compact systems take
only a few hours to install
only wire and piping need to be
run. The fast and easy
installation ensures minimal
disruption to customers in the
home or workplace. This Carrier
advantage
is
especially
beneficial in retrofit situations.
External Service Valves
Service valves are brass,
front seating type. The 38H
Series has flare connections,

sweat adapter kit is provided


for 7/8 tube size. Valves are
externally
located
so
refrigerant tube connections
can be made quickly and
easily. Each valve has a
service port for ease of
checking operating refrigerant
pressures.
Built-in reliability
Carrier split system outdoor
units are designed to provide
years of trouble-free operation.
The 38H Series condensing

units
are
the
only
dedicated commercial units
with all safety features
standard to ensure high
performance and lasting
reliability under the most
demanding situations. For
example, start capacitors
ensure dependable startups, especially during low
voltage conditions (down to
187 v). High-pressure and
low-pressure
safety
switches are standard

Table of contents
Features/Benefits.
ModelNumber Nomenclature..
Physical Data.
Combination Ratings
Air Deflector Accessory ..
Base Unit Dimensions..
Electrical Data
Detailed Performance Data 42TX Matching.
Detailed Performance Data FB4A Matching
Detailed Performance Data Ceiling Cassette Matching.
Detailed Performance Data Free Stand Matching...
Typical Wiring Schematic.
Application Data
Controls...
Appendix Long Line Guide Line.

Energy Efficiency labels


SASO 2663/2007

Page.
1
3
3
4
5
6-7
8
9,10
11,12
13,14
15
16-19
20
21
22

Model number nomenclature


38

18

- 00

Type
38Air-Cooled
Condenser

Factory Reference

Design Series
Series

38HK/HQ

Voltage
3 220160
5 220360
2 380360

Condenser Type
K-Cool
Q- Heat Pump

Fin Type
S- Standard Bare Fins
P- Pre-Coated Blue Fins

Compressor
C- Reciprocating
R- Rotary - Super Tropical

Application
D: Ducted application
FB4A or 42TX
24 Volt compressor contactor
U: Un Ducted application/Decorative
Ceiling Cassette, Hi wall,--etc.
220 Volt compressor contactor

Nominal Capacity in Tons (kW)


18 - 1.5 Tons (5.3 kW)
24 - 2 Tons (7 kW)
30 - 2.5 Tons (8.8 kW)
36 - 3 Tons (10.6 kW)
48 - 4 Tons (14 kW)
60 - 5 Tons (17.6 kW)
70 - 6 Tons (20.6 kW)

Physical Data
UNIT 38H
NOMINAL CAPACITY (Tons)
OPERATING WEIGHT (lb)
SHIPPING DIMENSIONS (in) (W X H X D)
COMPRESSOR
Cool Only
Heat Bump
REFRIGERANT TYPE
METERING DEVICE
Ducted Application
Un-ducted Application
FINISH
OUTDOOR FAN
RPM/CFM
Diameter, No. Blades
Motor Horsepower,
COIL DATA
Face Area (sq ft)
Tubes
Fins
FPI
REFRIGERANT LINES **
Connection Type
Liquid Line
Vapour Line
Max Length
Max Lift
Max Drop
* Sweat adapter kit is provided for 7/8 tube size.
** For long line application see Appendix.

18
1.5
123

24
30
2
2.5
139
154
37 x 29.7 x 16.1

36
3
161

48
60
70
4.0
5.0
6.0
211
227
253
50.4 X 40.2 X 30

Reciprocating
--

Rotary
R22

Nozzle, in the indoor unit


Nozzle, in the indoor unit
Gray
Propeller Type
1100/2000
860/3,000
18 in, 3
24 in, 3
1/12
1/4

Capillary Tube

6.3
Smooth
15

5/8 in.

12.05

Helical grooved
Aluminium, Double Wavy
17
17
15
12
Flare
3/8 inch
3/4 in.
50 ft
30 ft
30 ft

14

7/8 inch*

Combination ratings
Nominal
Cap.
MBtuh

18

38HK/HQ

24

30

36

48

60
70

Nominal
Cap.
MBtuh
18

24

30

Indoor Type

Indoor Model

Cassette
Console
High Wall
High Wall
High Wall
Ducted Split
Ducted Split
Cassette
Console
High Wall
High Wall
High Wall
Ducted Split
Ducted Split
Cassette
Console
High Wall
Ducted Split
Ducted Split
Cassette
Cassette
Console
High Wall
Free Stand
Free Stand
Ducted Split
Ducted Split
Cassette
Cassette
Free Stand
Ducted Split
Ducted Split
Ducted Split
Free Stand
Ducted Split
Ducted Split
Ducted Split
Ducted Split

40KMC018-3N-IU
42VMC18-3C
42KPL020-3
42KHC018-3
42EGC018-3
FB4ASNF018
42TX-018-301
40KMC024-3N-IU
42VMC24-3C
42KPL025-3
42KHD024-3
42EGC024-3
F4ASNF024
42TX-024-301
40KMC036-3
42VMC30-3C
42XP090C3
42TX-030-301
FB4ASNF030
42KMC-048-3N-IU
40KMC036-3N-IU
42VMC36-3C
42XP100C3
42SD6B
42HD6B
42TX-036-301
FB4ASNF036
40KMC048-3N-IU
40KMC048-3EN-IU
42SD6B
42TX-048-301
42MX-048-301
FB4ASNF048
42SD7B
42TX-060-301
42MX-060-301
FB4ASNF060
FB4ASNF070

Outdoor Model

Cap.
Btu/hr

CFM

Input Watts

E.E.R.

38HKR018US
38HKR018US
38HKR018UP
38HKR018UP
38HKR018US
38HKR018DS
38HKR018DS
38HKC024US
38HKR024US
38HKR024UP
38HKR024UP
38HKR024US
38HKC024DS
38HKC024DS
38HKC030US
38HKC030US
38HKC030US
38HKC030DS
38HKC030DS
38HKC036US
38HKC036US
38HKC036US
38HKC036US
38HKC036US
38HKC036US
38HKC036DS
38HKC036DS
38HKC048US
38HKC036US
38HKC048US
38HKC048DS
38HKC048DS
38HKC048DS
38HKC060US
38HKC060DS
38HKC060DS
38HKC060DS
38HKS070DS

18,000
18,000
19,000
18,000
18,000
19,000
19,000
21,750
21,000
22,500
21,750
21,750
23,000
23,000
27,500
29,000
27,500
30,500
30,500
35,000
35,000
32,500
35,000
35,500
35,500
35,000
35,800
41,000
41,000
44,000
44,000
47,500
46,500
55,000
56,500
58,300
56,800
68,750

425
440
550
550
550
650
650
450
530
650
650
650
650
650
750
675
730
800
1150
975
975
765
830
800
800
1100
1200
975
750
900
1400
1633
1500
1500
1600
1820
1650
1850

2.00
2.10
2.18
2.00
2.00
2.30
2.30
2.40
2.45
2.39
2.40
2.40
2.60
2.60
3.20
3.20
3.20
3.70
3.70
3.80
3.80
3.60
3.80
3.75
3.75
3.65
4.00
4.23
4.23
4.90
4.51
5.00
5.33
5.88
5.8
6.10
6.48
7.2

8.9
8.4
8.7
8.9
8.9
8.1
8.1
8.9
8.5
9.4
8.9
8.9
8.8
8.8
8.8
9.0
8.8
8.2
8.2
9.0
9.0
9.0
9.0
9.5
9.5
9.6
9.0
9.7
9.7
8.9
9.7
9.5
8.8
9.3
9.8
9.6
8.8
9.6

HEAT PUMP*
Indoor Type
Console
High Wall
High Wall
High Wall
Console
High Wall
High Wall
High Wall
Console

Indoor model
42VMC18-3H
42QPL020-3
42QHC018-3
42EGQ018-3
42VMC24-3H
42QPL025-3
42QHD024-3
42EGQ024-3
42VMC30-3H

LEGEND
CFM Cubic Feet Per Minute
EER Energy Efficiency Ratio
* as per SASO 2681/2007 standard

COOLING ONLY*

Outdoor model

CFM

38HQR018US
38HQR018UP
38HQR018UP
38HQR018US
38HQR024US
38HQR024UP
38HQR024UP
38HQR024US
38HQC030US

440
550
550
550
530
650
650
650
680

CAP.
Btu/hr
16,000
18,000
18,000
18,000
21,500
22,000
21,000
21,000
28,000

COOLING MODE
Input
E.E.R.
Watts
1.90
8.3
2.00
8.9
1.90
9.5
1.90
9.5
2.40
8.8
2.24
9.8
2.40
8.7
2.30
9.0
3.10
9.0

HEATING MODE
CAP.
Input
Btu/hr
Watts
4,900
1.70
4,750
1.63
5,100
1.70
5,000
1.70
5,300
1.86
5,700
1.83
5,500
1.86
5,250
1.84
8,500
2.70

COP
2.80
3.00
3.00
2.90
2.85
3.10
2.95
2.85
3.20

NOTES:
Cooling Standard: 80.6F db, 66.2F wb indoor entering-air temperature and 95.0 F
db air entering outdoor unit.
Heating Standard: 68 F db, 59 F wb indoor entering-air temperature and 44.6 F db
air entering outdoor unit.

Optional Deflector Accessory 38HK48-70


Part No. 38HK580622

38HK/HQ

The air deflector accessory converts the


direction of air flow in the side discharge outdoor
condensing units from horizontal direction to vertical
direction to make the unit more flexible and suitable
for top discharge applications.
The air deflector accessory consists of three pieces of
painted galvanized sheet metal parts assembled at
site.

Note:
This accessory is used only with 38HK048-070

38HK/HQ

Base Unit Dimensions 38H 12-36

Base Unit Dimensions 38H 048-070

048-070

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

3-1316

944.6

3-8916

1131.9

1-5116

433.4

1-6716

468.3

2-612

774.7

1-758

498.5

1-758

498.5

2-558

752.5

38HK/HQ

UNIT 38H

NOTES:
1. Required clearances: with coil facing wall
allow 8 in. minimum clearance on coil side and
coil end, and 3 ft minimum clearance on
compressor end and fan side.
2. Dimensions in [ ] are in millimeters.

Electrical Data
Size

18

38HK/HQ

24

30
36

48

60

70

Size
18
24

Cool Only
Power
Voltage
Supply
Min
Max

Compressor
FLA
LRA

220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/3/60
220/1/60
220/3/60
220/1/60
220/3/60
220/1/60
220/3/60
380/3/60
220/3/60
380/3/60

9.6
9.1
9.6
9.6
12.5
10.1
12.5
12.5
13.5
13.5
14.4
14.4
18.5
11.4
18.5
11.4
26.6
15.0
26.6
15.0
10.4
16.0
8.3

Outdoor Model
38HKC018US30
38HKR018US30
38HKC018UP30
38HKC018DS30
38HKC024US30
38HKR024US30
38HKC024UP30
38HKC024DS30
38HKC030US30
38HKC030DS30
38HKC036US30
38HKC036DS30
38HKC048US30
38HKC048US50
38HKC048DS30
38HKC048DS50
38HKC060US30
38HKC060US50
38HKC060DS30
38HKC060DS50
38HKC060DS20
38HKS070DS50
38HKS070DS20

55.0
40.0
55.0
55.0
60.0
53.0
60.0
60.0
82.0
82.0
88.0
88.0
118.0
78.0
118.0
78.0
178.0
114.0
178.0
114.0
55.0
150.0
75.0

0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

Heat Pump
Power
Voltage
Supply
Min
Max

Compressor
FLA
LRA

Fan
FLA

220/1/60
220/1/60
220/1/60
220/1/60

9.1
9.1
10.1
10.1

Outdoor Model
38HQR018US30
38HQR018UP30
38HQR024US30
38HQR024UP30

LEGEND
FLA Full Load Amps
LRA Locked Rotor Amps
RLA Rated Load Amps
MCA Minimum Circuit Amps
MOCP Maximum Over current Protection Amps

198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
342
198
342

198
198
198
198

242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
418
242
418

Fan
FLA

242
242
242
242

40.0
40.0
53.0
53.0

0.9
0.9
0.9
0.9

Detailed Performance Data


Matching 38HK with 42TX

18

24

30

36

CFM EWB
72
Evaporator
67
450 Air
62
57
72
67
550
62
57
72
67
650
62
57
72
67
450
62
57
72
67
550
62
57
72
67
650
62
57
72
67
600
62
57
72
67
700
62
57
72
67
800
62
57
72
67
800
62
57
72
67
950
62
57
72
67
1100
62
57

MBtuh
Sen
22.6 10.9
20.9 13.6
18.9 16.0
Capacity
18.0 16.8
22.9
Tot 11.3
21.3 14.3
19.3 17.1
18.8 17.6
23.1 11.6
21.5 15.0
19.7 18.0
19.5 18.2
26.6 12.5
24.6 15.5
22.3 18.2
21.2 19.2
27.0 12.9
25.1 16.3
22.8 19.5
22.2 20.1
27.2 13.2
25.4 17.1
23.3 20.5
23.0 20.8
34.9 15.4
32.3 19.1
29.2 22.5
27.7 23.7
35.3 15.9
32.9 20.2
29.9 24.0
29.1 24.8
35.6 16.4
33.3 21.1
30.5 25.3
30.1 25.6
40.7 18.6
37.6 23.0
34.0 27.1
32.4 28.5
41.2 19.2
38.3 24.3
34.9 29.0
33.9 29.9
41.6 19.7
38.8 25.5
35.6 30.5
35.1 30.9

85
Tot
Sys
Kw
2.0
2.0
1.9
1.9
2.1
2.0
1.9
1.9
2.1
2.1
2.0
2.0
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.3
2.3
2.2
2.2
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
2.9
2.8
2.8
3.1
3.0
3.0
2.9
3.2
3.1
3.0
3.0
3.3
3.2
3.1
3.1

MBtuh
Tot
Sen
21.8
10.7
19.9
13.2
17.8
15.5
Capacity
17.2
16.1
22.1
11.1
20.3
14.0
18.3
16.6
17.9
16.8
22.3
11.5
20.6
14.8
18.7
17.5
18.6
17.5
25.7
12.2
23.4
15.1
21.0
17.6
20.2
18.3
26.0
12.7
23.9
16.0
21.5
18.9
21.2
19.1
26.3
13.1
24.2
16.8
22.1
20.0
22.0
19.9
33.6
15.0
30.7
18.6
27.5
21.8
26.5
22.6
34.1
15.6
31.3
19.7
28.2
23.3
27.7
23.6
34.4
16.1
31.8
20.8
28.9
24.6
28.8
24.5
39.2
18.1
35.8
22.4
32.0
26.3
30.9
27.3
39.8
18.8
36.5
23.8
32.9
28.1
32.3
28.5
40.2
19.5
37.1
25.1
33.7
29.7
33.6
29.6

95
Tot
Sys
Kw
2.2
2.1
2.0
2.0
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.4
2.3
2.3
2.2
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
3.0
2.9
2.8
2.8
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.4
3.3
3.2
3.1
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

105

Tot
Tot
MBtuh
MBtuh
Sys
Sys
Tot
Sen
Kw
Tot
Sen
Kw
20.7 10.4 2.3 19.7
10.0 2.6
CONDENSER AIR ENTERING Deg. F
18.7 12.8 2.2 17.6
12.3 2.5
16.7 15.0 2.1 15.7
14.4 2.3
Capacity
Capacity
16.3 15.3 2.1 15.5
14.4 2.3
21.1 10.8 2.4 20.1
10.5 2.6
19.1 13.7 2.3 17.9
13.2 2.5
17.1 16.0 2.2 16.2
15.1 2.4
17.0 16.0 2.2 16.2
15.1 2.4
21.3 11.2 2.4 20.3
10.9 2.7
19.0 14.4 2.3 18.2
14.0 2.6
17.7 16.5 2.3 16.8
15.6 2.5
17.7 16.5 2.3 16.8
15.6 2.5
24.4 11.8 2.6 23.5
11.4 2.7
22.0 14.6 2.5 20.9
14.0 2.6
19.7 17.0 2.4 18.6
16.4 2.5
19.2 17.4 2.4 18.5
16.4 2.5
24.8 12.3 2.6 23.9
11.9 2.8
22.5 15.6 2.6 21.4
15.0 2.7
20.2 18.3 2.4 19.3
17.2 2.6
20.1 18.2 2.4 19.3
17.2 2.6
25.1 12.8 2.7 24.2
12.5 2.9
22.9 16.5 2.6 21.7
15.9 2.8
20.8 18.8 2.5 20.0
17.8 2.7
20.8 18.8 2.5 20.0
17.8 2.7
32.0 14.6 3.2 29.1
14.0 3.3
28.9 18.0 3.1 25.9
17.3 3.2
25.7 21.0 3.0 23.1
20.2 3.0
25.2 21.5 3.0 22.9
20.3 3.0
32.5 15.2 3.3 29.7
14.7 3.4
29.5 19.2 3.2 26.5
18.5 3.3
26.4 22.5 3.1 23.9
21.2 3.2
26.3 22.5 3.1 23.9
21.2 3.2
32.9 15.8 3.4 30.0
15.4 3.5
30.0 20.3 3.3 26.9
19.7 3.4
27.3 23.3 3.2 24.8
22.0 3.3
27.3 23.3 3.2 24.8
22.0 3.3
37.4 17.6 3.6 35.3
16.9 3.8
33.7 21.7 3.5 31.4
20.9 3.7
30.0 25.4 3.3 28.0
24.4 3.5
29.3 25.9 3.3 27.8
24.5 3.5
38.0 18.3 3.7 35.9
17.8 3.9
34.4 23.2 3.6 32.1
22.3 3.8
30.8 27.2 3.4 29.0
25.5 3.6
30.7 27.1 3.4 29.0
25.6 3.6
38.4 19.0 3.7 36.4
18.6 4.0
35.0 24.5 3.6 32.6
23.7 3.9
31.8 28.1 3.6 30.0
26.5 3.8
31.8 28.1 3.6 30.0
26.5 3.8

115
MBtuh
Tot
Sen
18.4
9.5
16.3 11.8
14.5 13.5
Capacity
14.5 13.5
18.7 10.1
16.6 12.6
15.2 14.1
15.2 14.1
19.0 10.5
18.0 13.4
15.8 14.7
15.8 14.7
21.9 10.9
19.4 13.5
17.3 15.4
17.3 15.4
22.3 11.5
19.7 14.4
18.1 16.1
18.1 16.1
22.6 12.0
20.0 15.3
18.8 16.7
18.8 16.7
27.2 13.4
24.0 16.6
21.5 19.0
21.5 19.0
27.7 14.1
24.5 17.8
22.5 19.9
22.5 19.9
28.0 14.8
24.8 18.9
23.3 20.6
23.3 20.6
33.0 16.2
29.1 20.0
26.0 22.9
26.0 22.9
33.5 17.1
29.6 21.5
27.2 24.0
27.2 24.0
33.9 17.9
30.0 22.8
28.2 24.9
28.2 24.9

120
Tot
Sys
Kw
2.7
2.6
2.5
2.5
2.8
2.7
2.6
2.6
2.8
2.7
2.6
2.6
2.9
2.8
2.7
2.7
3.0
2.8
2.7
2.7
3.0
2.9
2.8
2.8
3.5
3.3
3.2
3.2
3.7
3.5
3.4
3.4
3.7
3.6
3.5
3.5
4.1
3.9
3.7
3.7
4.2
4.0
3.8
3.8
4.3
4.1
4.0
4.0

MBtuh
Tot
Sen
9.2
4.8
8.1
5.9
7.3
6.8
Capacity
7.3
6.8
9.4
5.0
8.3
6.3
7.6
7.1
7.6
7.1
9.5
5.3
8.4
6.7
7.9
7.3
7.9
7.3
11.0
5.4
9.7
6.7
8.7
7.7
8.7
7.7
11.2
5.7
9.9
7.2
9.1
8.1
9.1
8.1
11.3
6.0
10.0
7.7
9.4
8.4
9.4
8.4
13.6
6.7
12.0
8.3
10.7
9.5
10.7
9.5
13.8
7.1
12.2
8.9
11.2
9.9
11.2
10.0
14.0
7.4
12.4
9.5
11.6
10.3
11.7
10.3
16.5
8.1
14.5
10.0
13.0
11.5
13.0
11.5
16.8
8.5
14.8
10.7
13.6
12.0
13.6
12.0
17.0
8.9
15.0
11.4
14.1
12.4
14.1
12.4

Tot
Sys
Kw
2.8
2.7
2.6
2.6
2.9
2.7
2.6
2.6
2.9
2.8
2.7
2.7
3.0
2.9
2.7
2.7
3.1
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.6
3.4
3.3
3.3
3.8
3.6
3.5
3.5
3.9
3.7
3.6
3.6
4.2
4.0
3.8
3.8
4.3
4.1
4.0
4.0
4.4
4.2
4.1
4.1

38HK/HQ

75

Nom
Cap.
Mbtuh

Detailed Performance Data


Matching 38HK with 42TX

38HK/HQ

Nom
Cap.
Mbtuh

48

60

Evaporator
Air

75

Capacity
MBtuh
CFM EWB
Sen
Tot
72
51.1 24.3
67
47.3 30.1
1100
62
42.8 35.5
57
40.7 37.4
72
51.8 25.1
67
48.2 31.8
1250
62
43.8 37.9
57
42.6 39.1
72
52.3 25.8
67
48.8 33.3
1400
62
44.7 40.0
57
44.1 40.5
72
63.8 30.3
67
59.0 37.6
1300
62
53.4 44.3
57
50.8 46.6
72
64.6 31.3
67
60.1 39.7
1450
62
54.7 47.3
57
53.1 48.8
72
65.2 32.2
67
60.9 41.6
1600
62
55.8 49.8
57
55.0 50.5

CONDENSER AIR ENTERING Deg. F


95
105

85
Tot
Sys
Kw
3.9
3.8
3.7
3.6
4.0
3.9
3.8
3.7
4.1
4.0
3.9
3.8
5.0
4.9
4.7
4.7
5.1
5.0
4.8
4.8
5.2
5.1
5.0
4.9

Capacity
MBtuh
Tot
Sen
49.3 23.7
45.0 29.4
40.3 34.4
38.9 35.7
50.0 24.7
45.9 31.1
41.4 36.8
40.6 37.3
50.5 25.5
46.6 32.8
42.4 38.9
42.2 38.7
61.5 29.6
56.1 36.6
50.2 42.9
48.5 44.5
62.4 30.8
57.3 38.8
51.6 45.8
50.7 46.5
63.0 31.8
58.1 40.9
52.8 48.5
52.6 48.3

Tot
Sys
Kw
4.2
4.0
3.9
3.9
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
5.4
5.2
5.0
5.0
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

Capacity
MBtuh
Tot
Sen
47.0 23.0
42.3 28.4
37.8 33.2
36.9 33.9
47.7 24.0
43.3 30.3
38.8 35.6
38.6 35.4
48.3 24.9
44.0 32.1
40.0 36.7
40.0 36.7
58.6 28.7
52.8 35.4
47.1 41.4
46.0 42.2
59.5 29.9
54.0 37.8
48.3 44.4
48.2 44.2
60.2 31.1
54.9 40.0
49.9 45.8
49.9 45.8

Tot
Sys
Kw
4.4
4.3
4.1
4.1
4.5
4.4
4.2
4.2
4.6
4.5
4.4
4.4
5.7
5.5
5.3
5.2
5.8
5.7
5.5
5.5
6.0
5.8
5.7
5.7

Capacity
MBtuh
Tot Sen
45.3 22.1
40.4 27.3
36.0 31.9
35.7 32.0
46.2 23.3
41.2 29.2
37.2 33.4
37.2 33.4
46.7 24.3
41.8 31.0
38.6 34.7
38.6 34.7
56.6
27.6
50.5
34.1
45.0
39.8
44.6
40.0
57.7
29.0
51.5
36.5
46.5
41.7
46.5
41.7
58.4
30.3
52.3
38.7
48.2
43.2
48.2 43.2

Tot
Sys
Kw
4.7
4.5
4.3
4.3
4.8
4.6
4.4
4.4
4.9
4.7
4.6
4.6
6.4
6.2
5.9
5.9
6.6
6.4
6.1
6.1
6.7
6.5
6.3
6.3

115
Capacity
MBtuh
Tot
Sen
42.3 21.2
37.4 26.2
33.4 30.0
33.4 30.0
43.0 22.3
38.1 28.1
35.0 31.4
35.0 31.4
43.6 23.4
38.6 29.8
36.2 32.6
36.3 32.6
52.9 26.4
46.7 32.7
41.8 37.4
41.8 37.4
53.8 27.8
47.6 35.0
43.7 39.1
43.7 39.2
54.4 29.2
48.2 37.2
45.3 40.6
45.3 40.6

120
Tot
Sys
Kw
5.0
4.8
4.5
4.5
5.1
4.9
4.7
4.7
5.2
5.0
4.8
4.8
6.9
6.5
6.2
6.2
7.0
6.7
6.4
6.4
7.1
6.9
6.7
6.7

Capacity
MBtuh
Tot Sen
21.2 10.6
18.7 13.1
16.7 15.0
16.7 15.0
21.5 11.2
19.0 14.0
17.5 15.7
17.5 15.7
21.8 11.7
19.3 14.9
18.1 16.3
18.1 16.3
26.5 13.2
23.4 16.3
20.9 18.7
20.9 18.7
26.9 13.9
23.8 17.5
21.8 19.6
21.8 19.6
27.2 14.6
24.1 18.6
22.6 20.3
22.7 20.3

Tot
Sys
Kw
5.2
4.9
4.7
4.7
5.3
5.0
4.8
4.8
5.4
5.1
5.0
5.0
7.1
6.7
6.4
6.4
7.3
6.9
6.7
6.7
7.4
7.1
6.9
6.9

Matching 38HK with 42MX


Nom
Cap.
Mbtuh

48

60

Evaporator
Air

CFM EWB
72
67
1250
62
57
72
67
1440
62
57
72
67
1550
62
57
72
67
1450
62
57
72
67
1600
62
57
72
67
1800
62
57

75

CONDENSER AIR ENTERING Deg. F


95
105

85

Capacity
Tot Capacity
MBtuh
MBtuh
Sys
Tot Sen Kw Tot Sen
52.9 24.3 4.3 51.0 23.7
48.9 30.1 4.2 46.5 29.4
44.2 35.5 4.1 41.6 34.4
42.1 37.4 4.0 40.2 35.7
53.6 25.1 4.4 51.7 24.7
49.8 31.8 4.3 47.5 31.1
45.3 37.9 4.2 42.8 36.8
44.1 39.1 4.1 42.0 37.3
54.1 25.8 4.5 52.2 25.5
50.5 33.3 4.4 48.2 32.8
46.2 40.0 4.3 43.8 38.9
45.6 40.5 4.2 43.6 38.7
67.8 32.6 5.2 65.4 31.9
62.7 40.5 5.1 59.6 39.4
56.7 47.7 5.0 53.4 46.2
53.9 50.2 4.9 51.5 47.9
68.7 33.7 5.4 66.3 33.1
63.9 42.7 5.2 60.8 41.8
58.1 50.9 5.1 54.8 49.4
56.5 52.5 5.0 53.8 50.1
69.3 34.7 5.5 66.9 34.2
64.7 44.8 5.4 61.7 44.1
59.2 53.7 5.2 56.1 52.2
58.4 54.4 5.2 55.9 52.0

Tot
Sys
Kw
4.6
4.5
4.3
4.3
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
5.6
5.5
5.3
5.2
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7

Capacity
MBtuh
Tot Sen
48.6 23.0
43.8 28.4
39.0 33.2
38.1 33.9
49.4 24.0
44.8 30.3
40.1 35.6
39.9 35.4
49.9 24.9
45.5 31.8
41.4 36.7
41.4 36.7
62.2 30.9
56.1 38.1
50.0 44.6
48.9 45.5
63.3 32.3
57.4 40.7
51.4 47.8
51.2 47.6
64.0 33.5
58.3 43.1
53.0 49.3
53.0 49.3

Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.

10

Tot
Sys
Kw
4.9
4.8
4.6
4.5
5.0
4.9
4.7
4.7
5.1
5.0
4.9
4.9
6.0
5.8
5.6
5.5
6.1
6.0
5.7
5.7
6.3
6.1
5.9
5.9

Capacity
MBtuh
Tot
Sen
45.2
22.1
40.2
27.3
35.9
31.9
35.5
32.0
46.0
23.3
41.1
29.2
37.1
33.4
37.1
33.4
46.6
24.3
41.7
31.0
38.5
34.7
38.5
34.7
55.9
29.7
49.8
36.7
44.4
42.8
44.0
43.0
56.9
31.3
50.8
39.3
45.9
44.9
45.9
44.9
57.6
32.6
51.6
41.7
47.6
46.6
47.6
46.6

Tot
Sys
Kw
5.1
4.9
4.7
4.6
5.2
5.0
4.8
4.8
5.3
5.1
5.0
5.0
6.2
6.0
5.7
5.7
6.3
6.2
5.9
5.9
6.5
6.3
6.1
6.1

115
Capacity
MBtuh
Tot Sen
42.2 21.2
37.2 26.2
33.3 30.0
33.3 30.0
42.9 22.3
37.9 28.1
34.8 31.4
34.8 31.4
43.4 23.4
38.5 29.8
36.1 32.6
36.1 32.6
52.2 28.4
46.1 35.2
41.2 40.3
41.2 40.3
53.1 30.0
46.9 37.7
43.1 42.2
43.1 42.2
53.7 31.4
47.6 40.1
44.7 43.7
44.7 43.7

120
Tot
Sys
Kw
5.4
5.2
4.9
4.9
5.5
5.3
5.1
5.1
5.6
5.4
5.3
5.3
6.6
6.3
6.0
6.0
6.7
6.4
6.2
6.2
6.9
6.6
6.4
6.4

Capacity
MBtuh
Tot
Sen
21.1
10.6
18.6
13.1
16.6
15.0
16.7
15.0
21.4
11.2
19.0
14.0
17.4
15.7
17.4
15.7
21.7
11.7
19.2
14.9
18.1
16.3
18.1
16.3
26.1
14.2
23.0
17.6
20.6
20.2
20.6
20.2
26.5
15.0
23.5
18.9
21.5
21.1
21.6
21.1
26.9
15.7
23.8
20.0
22.3
21.9
22.4
21.9

Tot
Sys
Kw
5.6
5.3
5.1
5.1
5.7
5.4
5.2
5.2
5.8
5.6
5.4
5.4
6.9
6.5
6.2
6.2
7.0
6.6
6.4
6.4
7.1
6.8
6.6
6.6

Detailed Performance Data


Matching 38HK with FB4A

75
MBtuh
Sen
22.5 11.6
20.8
14.4
Capacity
18.8 16.9
17.9
Tot 17.8
22.7 12.0
21.2 15.2
19.2 18.1
18.7 18.6
23.0 12.3
21.4 15.9
19.6 19.0
19.4 19.3
27.8 13.4
25.7 16.6
23.2 19.6
22.1 20.6
28.1 13.8
26.2 17.5
23.8 20.9
23.1 21.5
28.4 14.2
26.5 18.3
24.3 22.0
23.9 22.3
36.0 19.1
33.4 23.7
30.1 27.9
28.7 29.3
36.5 19.7
34.0 25.0
30.9 29.8
30.0 30.7
36.8 20.3
34.4 26.2
31.5 31.4
31.1 31.8
42.3 21.2
39.1 26.3
35.4 31.0
33.7 32.7
42.9 21.9
39.9 27.8
36.3 33.1
35.2 34.2
43.2 22.6
40.4 29.1
37.0 34.9
36.5 35.4

85
Tot
Sys
Kw
2.0
2.0
1.9
1.9
2.1
2.0
2.0
2.0
2.1
2.1
2.0
2.0
2.3
2.3
2.2
2.2
2.4
2.3
2.3
2.3
2.4
2.4
2.3
2.3
3.2
3.2
3.1
3.0
3.3
3.2
3.2
3.1
3.4
3.3
3.2
3.2
3.5
3.4
3.3
3.3
3.6
3.5
3.4
3.4
3.7
3.6
3.5
3.5

MBtuh
Tot Sen
21.7 11.3
19.8
14.0
Capacity
17.7 16.4
17.1 17.0
22.0 11.8
20.2 14.8
18.2 17.5
17.8 17.8
22.2 12.1
20.5 15.6
18.6 18.5
18.5 18.5
26.8 13.1
24.4 16.2
21.9 18.9
21.1 19.6
27.2 13.6
24.9 17.2
22.5 20.2
22.1 20.5
27.4 14.0
25.3 18.1
23.0 21.4
22.9 21.3
34.8 18.6
31.7 23.1
28.4 27.0
27.4 28.0
35.3 19.4
32.4 24.5
29.1 28.9
28.6 29.3
35.6 20.0
32.8 25.8
29.9 30.5
29.7 30.4
40.8 20.8
37.2 25.7
33.3 30.1
32.1 31.2
41.4 21.6
38.0 27.2
34.2 32.1
33.6 32.6
41.8 22.3
38.5 28.7
35.0 34.0
34.9 33.9

95
Tot
Sys
Kw
2.2
2.1
2.0
2.0
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.5
2.5
3.5
3.4
3.3
3.2
3.6
3.5
3.4
3.4
3.6
3.5
3.5
3.5
3.7
3.6
3.5
3.5
3.8
3.7
3.6
3.6
3.9
3.8
3.7
3.7

105

Tot
Tot
MBtuh
MBtuh
Sys
Sys
Tot
Sen
Kw
Tot
Sen
KwF
CONDENSER AIR ENTERING Deg.
20.6
11.0
2.3
20.1 10.6 2.7
18.6
13.5
2.3
18.0
13.0 2.6
Capacity
Capacity
16.6
15.8
2.2
16.0 15.2 2.5
16.2
16.1
2.1
15.9 15.3 2.5
21.0
11.4
3.0
20.5 11.1 2.8
19.0
14.4
2.3
18.3 13.9 2.7
17.0
17.0
2.2
16.6 15.9 2.6
17.0
16.9
2.2
16.5 15.9 2.6
21.2
11.9
2.4
20.8 11.6 2.8
19.3
15.3
2.4
18.6 14.8 2.7
17.6
17.5
2.3
17.2 16.5 2.6
17.6
17.5
2.3
17.1 16.5 2.6
25.5
12.7
2.7
24.1 12.2 2.9
23.0
15.6
2.6
21.5 15.0 2.8
20.5
18.3
2.5
19.1 17.6 2.6
20.0
18.6
2.5
19.0 17.6 2.6
25.9
13.2
2.7
24.5 12.8 2.9
23.5
16.7
2.7
21.9 16.1 2.9
21.0
19.6
2.6
19.8 18.4 2.7
21.0
19.5
2.6
19.8 18.4 2.7
26.2
13.7
2.8
24.8 13.4 3.0
23.9
17.7
2.7
22.2 17.1 2.9
21.7
20.2
2.7
20.5 19.1 2.8
21.7
20.2
2.7
20.5 19.1 2.8
33.1
18.1
3.7
31.2 17.4 3.9
29.8
22.3
3.6
27.8 21.4 3.8
26.6
26.1
3.5
24.8 25.0 3.6
26.0
26.6
3.4
24.6 25.2 3.5
33.6
18.9
3.8
31.8 18.3 4.0
30.5
23.8
3.7
28.4 23.0 3.9
27.3
27.9
3.6
25.7 26.3 3.7
27.2
27.8
3.6
25.7 26.2 3.7
34.0
19.6
3.9
32.2 19.1 4.1
31.0
25.2
3.8
28.8 24.4 3.9
28.2
28.8
3.7
26.6 27.2 3.8
28.2
28.8
3.7
26.6 27.2 3.8
38.9
20.1
4.0
37.9 19.4 4.2
35.0
24.8
3.9
33.7 23.9 4.0
31.2
29.0
3.7
30.1 27.9 3.8
30.5
29.6
3.7
29.8 28.0 3.8
39.5
21.0
4.1
38.6 20.3 4.3
35.8
26.5
4.0
34.4 25.6 4.1
32.1
31.1
3.8
31.1 29.2 3.9
31.9
31.0
3.8
31.1 29.2 3.9
39.9
21.8
4.2
39.1 21.3 4.3
36.4
28.0
4.1
35.0 27.1 4.2
33.1
32.1
4.0
32.3 30.3 4.1
33.1
32.1
4.0
32.2 30.3 4.1

115
MBtuh
Tot
Sen
19.3
10.1
17.1
12.5
Capacity
15.3
14.3
15.3
14.3
19.7
10.6
17.4
13.4
16.0
15.0
16.0
15.0
19.9
11.1
17.6
14.2
16.6
15.5
16.6
15.5
23.4
11.7
20.6
14.4
18.4
16.5
18.4
16.5
23.7
12.3
21.0
15.5
19.3
17.3
19.3
17.3
24.0
12.9
21.3
16.4
20.0
17.9
20.0
17.9
29.2
16.6
25.8
20.6
23.0
23.6
23.0
23.6
29.7
17.5
26.3
22.0
24.1
24.6
24.1
24.6
30.0
18.4
26.6
23.4
25.0
25.6
25.0
25.6
35.4
18.5
31.2
22.9
27.9
26.2
27.9
26.2
36.0
19.5
31.8
24.5
29.2
27.4
29.2
27.4
36.4
20.4
32.3
26.1
30.3
28.5
30.3
28.5

120
Tot
Sys
Kw
2.9
2.8
2.6
2.6
2.9
2.8
2.7
2.7
2.9
2.8
2.7
2.7
3.1
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.2
3.1
3.0
3.0
4.1
3.9
3.8
3.8
4.2
4.0
3.9
3.9
4.3
4.1
4.0
4.0
4.4
4.2
4.0
4.0
4.5
4.3
4.2
4.2
4.6
4.4
4.3
4.3

MBtuh
Tot Sen
18.3 9.7
16.1
12.1
Capacity
14.6 13.6
14.6 13.6
18.6 10.3
16.4 13.0
15.2 14.3
15.2 14.3
18.9 10.8
16.6 13.8
15.8 14.8
15.8 14.8
22.1 11.2
19.4 14.0
17.6 15.8
17.6 15.8
22.5 11.9
19.8 15.0
18.4 16.5
18.4 16.5
22.8 12.5
20.1 16.0
19.1 17.1
19.1 17.1
27.7 16.0
24.3 20.0
22.0 22.5
22.0 22.5
28.1 17.0
24.7 21.4
23.0 23.5
23.0 23.5
28.5 17.8
25.1 22.8
23.8 24.3
23.8 24.3
33.5 17.9
29.4 22.2
26.6 25.0
26.6 25.0
34.1 18.9
30.0 23.8
27.9 26.2
27.9 26.2
34.5 19.9
30.4 25.3
28.9 27.1
28.9 27.1

Tot
Sys
Kw
3.0
2.8
2.7
2.7
3.1
2.9
2.8
2.8
3.0
2.9
2.8
2.8
3.2
3.0
2.9
2.9
3.2
3.1
3.0
3.0
3.3
3.2
3.1
3.1
4.3
4.1
3.9
3.9
4.4
4.2
4.0
4.0
4.5
4.3
4.2
4.2
4.6
4.4
4.2
4.2
4.7
4.5
4.3
4.3
4.8
4.6
4.5
4.5

11

38HK/HQ

to
Nom
Cap.
MBtuh CFM,
BP EWB
Evapora
r Air72
67
525
62
57
72
67
18
600
62
57
72
67
675
62
57
72
67
550
62
57
72
67
24
625
62
57
72
67
700
62
57
72
67
1000
62
57
72
67
30
1150
62
57
72
67
1300
62
57
72
67
1050
62
57
72
67
36
1200
62
57
72
67
1350
62
57

Detailed Performance Data


Matching 38HK with FB4A

38HK/HQ

Nom
Cap.
MBtuh

48

60

Evaporator
Evaporator
AirAir
CFM EWB
72
67
1300
62
57
72
67
1500
62
57
72
67
1700
62
57
72
67
1450
62
57
72
67
1650
62
57
72
67
1850
62
57
1300

70

1500

1700

72
67
62
57
72
67
62
57
72
67
62
57

75
Capacity
Capacity
MBtuh
Tot
Tot Sen
54.9 28.7
50.8 35.6
46.0 42.0
43.7 44.1
55.7 29.7
51.8 37.6
47.1 44.8
45.8 46.2
56.2 30.5
52.4 39.4
48.0 47.2
47.4 47.8
67.1 32.3
62.1 40.1
56.1 47.3
53.4 49.7
68.0 33.4
63.3 42.3
57.5 50.4
55.9 52.1
68.6 34.4
64.0 44.3
58.7 53.2
57.9 53.9

Tot
Sys
Kw
4.6
4.5
4.4
4.3
4.7
4.6
4.5
4.4
4.8
4.7
4.6
4.6
5.7
5.5
5.4
5.3
5.8
5.7
5.5
5.5
5.9
5.8
5.7
5.6

79.2
79.2 37.7
37.76.5
79.2 46.7
37.7 6.5
73.3
73.3 46.76.3
73.3 55.1
46.7 6.3
66.2
66.2 55.16.1
66.2 57.9
55.1 6.1
63.0
63.0 57.96.1
80.2
38.9
80.2 38.96.6
74.6
74.6 49.3
49.36.5
67.9
67.9 58.8
58.86.3
67.9 60.7
58.8 6.3
66.0
66.0 60.76.2
66.0 40.0
60.7 6.2
80.9
80.9 40.06.8
80.9 51.7
40.0 6.8
75.5
75.5 51.76.6
75.5 62.0
51.7 6.6
69.2
69.2 62.06.5
6.5
68.3
68.3 62.8
62.86.4
6.4

85
Capacity
Capacity
MBtuh
Tot
Sen
53.0
28.1
48.4
34.7
43.3
40.6
41.8
42.2
53.8
29.1
49.3
36.8
44.4
43.4
43.7
44.1
54.2
30.1
50.0
38.8
45.5
45.9
45.3
45.8
64.7
31.6
59.1
39.1
52.9
45.8
51.0
47.5
65.7
32.8
60.3
41.5
54.3
48.9
53.3
49.6
66.3
33.9
61.1
43.7
55.6
51.7
55.4
51.6

76.4
76.4
76.4
69.7
69.7
69.7
62.3
62.3
62.3
60.2
60.2
77.4
77.4
71.1
71.1
64.0
64.0
64.0
62.9
62.9
62.9
78.2
78.2
78.2
72.1
72.1
72.1
65.6
65.6
65.6
65.3
5.3
5.3

CONDENSER
AIR
ENTERING
FF
CONDENSER
AIR
ENTERINGDeg.
Deg.
95
105
Capacity
Capacity
Tot
Capacity Tot
Capacity Tot
MBtuh
MBtuh
Sys
Sys
Sys
Kw Tot
Sen
Kw
Tot
Sen Kw
5.0 50.5
27.2
5.3
47.6
26.2 5.4
4.8 45.5
33.6
5.1
42.5
32.3 5.2
4.6 40.6
39.2
4.9
37.8
37.7 4.9
4.6 39.6
40.0
4.9
37.5
37.9 4.9
5.1 51.3
28.4
5.4
48.5
27.5 5.5
35.8
5.3
4.9 46.5
43.3
34.5 5.3
4.8 41.6
42.0
5.1
39.1
39.5 5.1
4.8 41.5
41.9
5.1
39.1
39.5 5.1
5.2 51.9
29.5
5.5
49.1
28.7 5.6
5.0 47.3
37.9
5.4
44.0
36.7 5.4
4.9 43.0
43.4
5.2
40.6
41.0 5.3
4.9 43.0
43.4
5.2
40.5
40.9 5.3
6.1 61.6
30.6
6.5
59.4
29.5 6.6
5.9 55.6
37.8
6.3
52.9
36.4 6.4
5.7 49.6
44.2
6.1
47.1
42.4 6.1
5.7 48.4
45.1
6.0
46.7
42.6 6.1
6.2 62.6
32.0
6.7
60.5
31.0 6.8
40.3
6.5
6.1 56.8
54.0
38.9 6.6
5.9 50.9
47.4
6.2
48.8
44.5 6.3
5.9 50.7
47.2
6.2
48.7
44.5 6.3
6.4 63.3
33.2
6.8
61.2
32.4 6.9
6.2 57.7
42.7
6.6
54.8
41.3 6.7
6.0 52.5
48.9
6.4
50.5
46.1 6.5
6.0 52.5
48.9
6.4
50.5
46.1 6.5

36.8
36.87.0
36.8 6.8
7.0
45.5
45.5
45.5 6.5
6.8
53.3
53.3
53.3 6.5
6.5
55.3
55.3
38.2
7.1
38.2
48.3
48.36.9
57.0
57.06.7
57.0 6.7
6.7
57.8
57.8
57.8 7.3
6.7
39.5
39.5
39.5 7.1
7.3
50.9
50.9
50.9 6.9
7.1
60.3
60.3
60.3 6.9
6.9
60.1
60.1
60.1 6.9

72.7
72.7
72.7
65.5
65.5
65.5
58.5
58.5
58.5
57.1
57.1
73.9
73.9
73.9
67.0
67.0
60.0
60.0
60.0
59.8
59.8
59.8
74.7
4.7
4.7
68.1
68.1
68.1
61.9
61.9
61.9
61.9

35.7
35.7
35.7
44.0
44.0
44.0
51.5
51.5
51.5
52.5
52.5
37.2
37.2
47.0
47.0
55.2
55.2
55.2
55.0
55.0
55.0
38.7
38.7
38.7
49.8
49.8
49.8
57.0
57.0
57.0
57.0
57.0

Multipliers to Determine the Performance With Other Indoor Coils


Condenser
Evaporator
Cooling Cap.
Power
N. Cap. MBtuh
N. Cap. MBtuh
18
24
1.10
1.07
24
30
1.05
1.05
30
36
1.03
1.05
36
42
1.04
1.05
48
60
1.05
1.05
60
70
1.02
1.03

12

7.4
7.4
7.2
7.2
6.9
6.9
6.8
7.6
7.4
7.4
7.1
7.1
7.1
7.1
7.8
7.8
7.6
7.6
7.4
7.4
7.4

68.6
68.6
68.6
61.2
61.2
61.2
54.5
54.5
54.5
54.0
54.0
69.9
69.9
62.4
56.4
56.4
56.4
56.4
56.4
56.4
70.8
70.8
70.8
63.4
63.4
58.5
58.5
58.4
58.4
58.4

34.3
34.3 8.0
34.3 7.7
8.0
42.4
42.4
42.4 7.3
7.7
49.4
49.4
49.4 7.3
7.3
49.7
49.7
36.1
8.1
36.1
45.3
45.3 7.9
51.9
51.9 7.5
51.9 7.5
7.5
51.8
51.8
51.8 8.3
7.5
37.7
37.7
37.7 8.0
8.3
48.1
48.1
53.8
7.8
53.8
7.8
53.7
53.7 7.8
53.7 7.8

115
Capacity
Capacity
MBtuh
Tot Sen
44.5 25.0
39.3 31.0
35.1 35.5
35.1 35.5
45.2 26.4
39.5 33.2
36.7 37.1
36.7 37.1
45.8 27.6
40.6 35.2
38.1 38.5
38.1 38.5
55.5 28.2
49.0 34.9
43.8 39.9
43.8 40.0
56.4 29.7
49.8 37.4
45.8 41.8
45.8 41.8
57.1 31.1
50.5 39.7
47.5 43.3
47.5 43.3

Tot
Sys
Kw
5.7
5.5
5.2
5.2
5.9
5.6
5.4
5.4
6.0
5.7
5.6
5.6
7.1
6.7
6.4
6.4
7.2
6.9
6.6
6.6
7.4
7.1
6.9
6.9

64.1
64.1 32.9
32.98.5
64.1 40.7
32.9 8.5
56.6
56.6 40.78.1
56.6 46.5
40.7 8.1
50.6
50.6 46.57.7
50.6 46.6
46.5
50.6
50.6 46.67.7
65.2
34.6
65.2 34.68.6
57.6
57.6 43.6
43.68.3
52.9
52.9 48.7
48.78.0
52.9 48.7
48.7 8.0
52.9
52.9 48.78.0
52.9 36.3
48.7 8.0
66.0
66.0 36.38.8
66.0 46.3
36.3 8.8
58.5
58.5 46.38.5
58.5 50.5 8.2
8.5
54.9
54.9 50.5
54.9 50.5
50.5 8.2
54.9
54.9 50.58.2
54.9 50.5 8.2

120
Capacity
Capacity
MBtuh
Tot Sen
42.2 24.1
37.0 30.1
33.5 33.8
33.5 33.8
42.9 25.5
37.7 32.2
35.0 35.4
35.0 35.4
43.4 26.8
38.2 34.2
36.3 36.6
36.3 36.6
52.5 27.2
46.1 33.8
41.8 38.1
41.8 38.1
53.4 28.8
47.0 36.3
43.7 39.9
43.7 39.8
54.1 30.2
47.6 38.6
45.2 41.3
45.2 41.3

60.7
60.7 31.7
31.7
60.7 39.4
31.7
53.3
53.3 39.4
53.3 44.4
39.4
48.3
48.3 44.4
48.3
48.3 44.4
44.4
61.8
61.8 33.5
33.5
54.3
54.3 42.3
42.3
50.5
50.5 46.4
46.4
50.5 46.4
46.4
50.5
50.5 46.4
50.5 35.2
46.4
62.6
62.6 35.2
62.6 45.0
35.2
55.1
55.1 45.0
55.1 48.1
45.0
52.3
52.3 48.1
52.3
52.3 48.1
48.1
52.3

Tot
Sys
Kw
6.0
5.6
5.4
5.4
6.1
5.8
5.6
5.6
6.2
5.9
5.8
5.8
7.3
6.9
6.6
6.6
7.5
7.1
6.9
6.9
7.6
7.3
7.1
7.1

8.8
8.8
8.3
8.3
7.9
8.0
8.9
8.5
8.2
8.2
8.2
8.2
8.2
9.1
9.1
8.7
8.7
8.5
8.5
8.5
8.5

Notes:
1. Net Capacities shown include a deduction for evaporator fan
motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.

Detailed Performance Data

Nom
Cap.
Mbtuh

Evaporator
Air

CFM
300

18

375

425

325

24

400

450

570
36
Evap
Evap &
&
650
30
Cond
750

570
36
Evap
&
36
Cond

650

750

680
48
Evap
&
36
Cond

830

975

75
Capacity
MBtuh
EWB Tot Sen
72 20.9 9.1
67 19.4 11.2
62 17.5 13.2
57 16.6 13.9
72 21.2 9.4
67 19.7 11.9
62 17.9 14.1
57 17.4 14.6
72 21.4 9.6
67 20.0 12.4
62 18.3 14.9
57 18.0 15.1
72 26.7 12.7
67 24.7 15.8
62 22.4 18.6
57 21.3 19.5
72 27.1 13.1
67 25.2 16.6
62 22.9 19.8
57 22.3 20.5
72 27.3 13.5
67 25.5 17.4
62 23.4 20.9
57 23.1 21.2
72 32.0 13.5
67 29.6 16.7
62 26.7 19.7
57 25.4 20.7
72 32.4 13.9
67 30.1 17.6
62 27.4 21.0
57 26.6 21.7
72 32.7 14.3
67 30.5 18.5
62 27.9 22.2
57 27.6 22.4
72 34.9 14.0
67 32.3 17.4
62 29.2 20.5
57 27.7 21.6
72 35.3 14.5
67 32.9 18.4
62 29.9 21.9
57 29.1 22.6
72 35.6 14.9
67 33.3 19.2
62 30.5 23.1
57 30.1 23.4
72 37.2 16.2
67 34.4 20.1
62 31.1 23.7
57 29.6 24.9
72 37.7 16.7
67 35.1 21.2
62 31.9 25.3
57 31.0 26.1
72 38.0 17.2
67 35.5 22.2
62 32.5 26.6
57 32.08 26.99

Tot
Sys
Kw
1.8
1.8
1.7
1.7
1.9
1.8
1.8
1.8
1.9
1.9
1.8
1.8
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.3
2.3
2.2
2.2
2.7
2.7
2.6
2.6
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.1
3.1
3.0
3.0
3.1
3.0
2.9
2.9
3.2
3.1
3.0
3.0
3.2
3.2
3.1
3.06

85
Capacity
MBtuh
Tot Sen
20.2
8.9
18.4 10.9
16.5 12.8
15.9 13.3
20.5
9.2
18.8 11.6
16.9 13.7
16.6 13.9
20.7
9.5
19.1 12.2
17.3 14.5
17.3 14.4
25.8 12.4
23.5 15.4
21.1 18.0
20.3 18.7
26.2 12.9
24.0 16.3
21.6 19.2
21.2 19.5
26.4 13.3
24.4 17.2
22.1 20.3
22.1 20.3
30.8 13.2
28.1 16.3
25.2 19.1
24.3 19.8
31.3 13.7
28.7 17.3
25.8 20.4
25.4 20.7
31.6 14.1
29.1 18.2
26.5 21.6
26.4 21.5
33.6 13.7
30.7 17.0
27.5 19.9
26.5 20.6
34.1 14.2
31.3 18.0
28.2 21.2
27.7 21.5
34.4 14.7
31.8 18.9
28.9 22.5
28.8 22.4
35.9 15.8
32.7 19.6
29.3 22.9
28.3 23.8
36.4 16.4
33.4 20.8
30.1 24.5
29.6 24.9
36.7 17.0
33.9 21.9
30.8 25.9
30.70 25.83

Tot
Sys
Kw
2.0
1.9
1.9
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
2.0
2.4
2.3
2.2
2.2
2.4
2.4
2.3
2.3
2.5
2.4
2.4
2.4
2.9
2.9
2.8
2.7
3.0
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.2
3.1
3.0
3.0
3.3
3.2
3.1
3.1
3.3
3.3
3.2
3.2
3.3
3.2
3.1
3.1
3.4
3.3
3.2
3.2
3.5
3.4
3.3
3.28

CONDENSER AIR ENTERING Deg. F


95
105
115
Capacity
Capacity
Capacity
Tot
Tot
MBtuh
MBtuh
MBtuh
Sys
Sys
Tot
Sen
Kw
Tot
Sen
Kw
Tot Sen
19.2
8.6
2.1
18.4
8.3
2.3 17.2 7.9
17.3
10.6 2.0
16.4
10.2
2.2 15.2 9.8
15.4
12.4 2.0
14.6
11.9
2.1 13.6 11.2
15.1
12.6 1.9
14.5
11.9
2.1 13.6 11.2
19.5
9.0
3.0
18.8
8.7
2.4 17.5 8.3
17.7
11.3 2.1
16.8
10.9
2.3 15.5 10.5
15.9
13.3 2.0
15.1
12.5
2.2 14.2 11.7
15.8
13.2 2.0
15.2
12.5
2.2 14.2 11.7
19.7
9.3
2.2
19.0
9.1
2.4 17.7 8.7
18.0
12.0 2.1
17.0
11.6
2.3 15.7 11.1
16.4
13.7 2.1
15.7
12.9
2.3 14.7 12.1
16.4
13.7 2.1
15.7
12.9
2.3 14.8 12.1
24.6
12.0 2.5
23.2
11.6
2.8 21.7 11.1
22.1
14.9 2.5
20.7
14.3
2.7 19.1 13.7
19.7
17.4 2.4
18.4
16.7
2.6 17.1 15.7
19.3
17.7 2.3
18.3
16.8
2.6 17.1 15.7
25.0
12.6 2.6
23.6
12.2
2.9 22.0 11.7
22.6
15.9 2.5
21.1
15.3
2.8 19.5 14.7
20.3
18.6 2.4
19.0
17.5
2.7 17.9 16.4
20.2
18.5 2.4
19.1
17.5
2.7 17.9 16.4
25.2
13.0 2.7
23.9
12.7
2.9 22.3 12.2
23.0
16.8 2.6
21.4
16.2
2.8 19.7 15.6
20.9
19.2 2.5
19.7
18.1
2.8 18.5 17.0
20.9
19.2 2.5
19.8
18.1
2.8 18.6 17.0
29.4
12.8 3.1
28.0
12.3
3.4 26.1 11.7
26.5
15.7 3.0
24.9
15.1
3.2 23.1 14.5
23.6
18.4 2.9
22.2
17.7
3.1 20.6 16.6
23.1
18.8 2.9
22.0
17.8
3.1 20.6 16.6
29.8
13.3 3.2
28.5
12.9
3.4 26.6 12.4
27.1
16.8 3.1
25.5
16.2
3.3 23.5 15.6
24.2
19.7 3.0
23.0
18.5
3.2 21.6 17.4
24.1
19.7 3.0
23.0
18.5
3.2 21.6 17.4
30.2
13.8 3.3
28.9
13.5
3.5 26.9 13.0
27.5
17.8 3.2
25.8
17.2
3.4 23.8 16.5
25.0
20.4 3.1
23.8
19.2
3.3 22.4 18.1
25.0
20.4 3.1
23.8
19.2
3.3 22.4 18.1
32.0
13.3 3.4
30.5
12.8
3.7 28.5 12.2
28.9
16.4 3.3
27.2
15.8
3.5 25.2 15.1
25.7
19.2 3.2
24.2
18.4
3.4 22.5 17.3
25.2
19.6 3.1
24.0
18.5
3.3 22.5 17.3
32.5
13.9 3.5
31.1
13.4
3.7 29.0 12.9
29.5
17.5 3.4
27.8
16.9
3.6 25.6 16.2
26.4
20.5 3.3
25.1
19.3
3.5 23.5 18.1
26.3
20.5 3.3
25.1
19.3
3.5 23.6 18.1
32.9
14.4 3.6
31.5
14.0
3.8 29.4 13.5
30.0
18.5 3.5
28.2
17.9
3.7 26.0 17.2
27.3
21.2 3.4
26.0
20.0
3.6 24.4 18.8
27.3
21.2 3.4
26.0
20.0
3.6 24.4 18.8
34.2
15.3 3.5
33.2
14.8
3.9 31.0 14.1
30.8
18.9 3.4
29.6
18.2
3.7 27.4 17.5
27.5
22.1 3.3
26.4
21.2
3.5 24.5 20.0
26.8
22.6 3.3
26.2
21.4
3.5 24.5 20.0
34.7
16.0 3.6
33.8
15.5
3.9 31.6 14.9
31.5
20.2 3.5
30.2
19.5
3.8 27.9 18.7
28.2
23.7 3.4
27.3
22.3
3.7 25.6 20.9
28.1
23.6 3.4
27.3
22.3
3.7 25.6 20.9
35.1
16.6 3.7
34.3
16.2
4.0 31.9 15.6
32.0
21.4 3.6
30.7
20.7
3.9 28.3 19.9
29.1
24.5 3.5
28.3
23.1
3.8 26.6 21.7
29.11 24.49 3.51 28.31 23.11 3.78 26.59 21.71

Tot
Sys
Kw
2.5
2.4
2.2
2.2
2.5
2.4
2.3
2.3
2.6
2.4
2.4
2.4
3.0
2.9
2.7
2.7
3.1
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.6
3.4
3.2
3.2
3.6
3.5
3.4
3.4
3.7
3.6
3.5
3.5
3.9
3.7
3.5
3.5
4.0
3.8
3.7
3.7
4.1
3.9
3.8
3.8
4.1
3.9
3.7
3.7
4.2
4.0
3.9
3.9
4.3
4.1
4.0
4.00

120
Capacity
Tot
MBtuh
Sys
Tot Sen
Kw
8.6
3.9
2.6
7.6
4.9
2.4
6.8
5.6
2.3
6.8
5.6
2.3
8.8
4.2
2.6
7.7
5.2
2.5
7.1
5.9
2.4
7.1
5.9
2.4
8.9
4.4
2.7
7.8
5.6
2.5
7.4
6.1
2.5
7.4
6.1
2.5
10.8 5.5
3.1
9.6
6.9
2.9
8.5
7.8
2.8
8.5
7.9
2.8
11.0 5.8
3.2
9.7
7.3
3.0
8.9
8.2
2.9
8.9
8.2
2.9
11.1 6.1
3.2
9.9
7.8
3.1
9.3
8.5
3.0
9.3
8.5
3.0
13.1 5.9
3.7
11.5 7.3
3.5
10.3 8.3
3.3
10.3 8.3
3.4
13.3 6.2
3.8
11.8 7.8
3.6
10.8 8.7
3.5
10.8 8.7
3.5
13.5 6.5
3.9
11.9 8.3
3.7
11.2 9.0
3.6
11.2 9.0
3.6
14.3 6.1
4.0
12.6 7.6
3.8
11.3 8.7
3.7
11.3 8.7
3.7
14.5 6.4
4.1
12.8 8.1
3.9
11.8 9.1
3.8
11.8 9.1
3.8
14.7 6.8
4.2
13.0 8.6
4.0
12.2 9.4
3.9
12.2 9.4
3.9
15.5 7.1
4.3
13.7 8.7
4.0
12.2 10.0
3.9
12.3 10.0
3.9
15.8 7.4
4.3
14.0 9.4
4.1
12.8 10.5
4.0
12.8 10.5
4.0
16.0 7.8
4.4
14.1 9.9
4.2
13.3 10.9
4.1
13.30 10.86 4.13

13

38HK/HQ

Matching 38HK with Ceiling Cassette

Detailed Performance Data

Matching 38HK with Ceiling Cassette

Nom Cap.
Mbtuh

Evaporator
Air
CFM

38HK/HQ

680

48 Evap
&
48
Cond

830

975

EWB
72
67
62
57
72
67
62
57
72
67
62
57

75
Cap.
Tot Sen
47.3 20.8
43.7 25.9
39.5 30.5
37.6 32.1
47.9 21.5
44.5 27.3
40.5 32.5
39.4 33.6
48.3 22.1
45.1 28.6
41.3 34.3
40.8 34.7

Tot
Sys
3.63
3.54
3.44
3.40
3.72
3.63
3.53
3.50
3.81
3.72
3.62
3.60

85
Cap. MBtuh
Tot
Sen
45.6 20.4
41.6 25.2
37.2 29.5
35.9 30.6
46.2 21.2
42.4 26.7
38.2 31.5
37.6 32.0
46.7 21.9
43.1 28.1
39.1 33.4
39.0 33.2

Tot
Sys
3.91
3.80
3.66
3.62
3.98
3.89
3.77
3.75
4.07
3.96
3.86
3.86

CONDENSER AIR ENTERING Deg. F


105
115
95
Tot Cap. MBtuh Tot Cap. MBtuh
Cap. MBtuh
Sys
Tot
Sen
Tot Sen Sys Tot Sen
43.4 19.7 4.17
41.0 19.0 4.46 38.3 18.2
39.1 24.4 4.05
36.5 23.4 4.30 33.8 22.5
34.9 28.5 3.87
32.5 27.4 4.08 30.2 25.7
34.1 29.1 3.83
32.3 27.5 4.07 30.2 25.8
44.1 20.6 4.26
41.7 20.0 4.56 38.9 19.2
40.0 26.0 4.15
37.3 25.1 4.43 34.4 24.1
35.8 30.5 3.98
33.7 28.7 4.22 31.6 26.9
35.7 30.4 3.98
33.7 28.7 4.22 31.6 26.9
42.3 20.9 4.65 39.4 20.1
44.6 21.4 4.35
37.8 26.6 4.50 34.9 25.6
40.7 27.5 4.24
37.0 31.5 4.13
34.9 29.7 4.36 32.8 27.9
37.0 31.5 4.13
34.9 29.8 4.36 32.8 27.9

Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.

14

Tot
Sys
4.76
4.53
4.32
4.32
4.85
4.64
4.46
4.46
4.94
4.75
4.61
4.61

120
Cap.
Tot Sen
36.4 17.3
32.1 21.4
28.7 24.5
28.7 24.5
37.0 18.2
32.7 22.9
30.0 25.6
30.0 25.6
37.4 19.1
33.2 24.3
31.1 26.5
31.2 26.5

Tot
Sys
4.94
4.66
4.45
4.46
5.02
4.76
4.60
4.60
5.12
4.89
4.77
4.77

Detailed Performance Data

Nom
Cap.
Mbtuh

Evaporator
Air
CFM

600

36

700

800

700

48

800

900

1000

60

1250

1500

EWB
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

75
85
Capacity Tot Capacity Tot
MBtuh
MBtuh
Sys
Sys
Tot Sen Kw Tot Sen Kw
41.3 19.4 3.2 39.8 18.9 3.5
38.2 24.0 3.1 36.3 23.4 3.4
34.5 28.3 3.0 32.5 27.4 3.2
32.8 29.8 3.0 31.4 28.5 3.2
41.8 20.0 3.3 40.4 19.7 3.5
38.9 25.4 3.2 37.0 24.9 3.4
35.4 30.2 3.1 33.4 29.3 3.3
34.4 31.2 3.1 32.8 29.8 3.3
42.2 20.6 3.4 40.7 20.3 3.6
39.4 26.6 3.3 37.6 26.2 3.5
36.1 31.9 3.2 34.2 31.0 3.4
35.6 32.3 3.2 34.1 30.9 3.4
50.9 21.5 3.7 49.1 21.0 4.0
47.1 26.7 3.7 44.8 26.0 3.9
42.6 31.4 3.6 40.1 30.4 3.8
40.5 33.0 3.5 38.7 31.6 3.7
51.6 22.2 3.8 49.8 21.8 4.1
48.0 28.1 3.7 45.7 27.6 4.0
43.6 33.5 3.6 41.2 32.5 3.9
42.4 34.6 3.6 40.5 33.0 3.9
52.1 22.8 3.9 50.3 22.5 4.2
48.6 29.5 3.8 46.4 29.0 4.1
44.5 35.4 3.7 42.2 34.4 4.0
43.9 35.8 3.7 42.0 34.3 4.0
63.9 30.6 5.0 61.7 29.9 5.4
59.2 38.0 4.9 56.3 37.0 5.3
53.5 44.8 4.8 50.3 43.3 5.1
50.9 47.1 4.7 48.6 45.0 5.0
64.8 31.7 5.2 62.5 31.1 5.5
60.2 40.1 5.0 57.4 39.3 5.4
54.8 47.8 4.9 51.7 46.3 5.2
53.3 49.3 4.9 50.8 47.0 5.2
65.4 32.5 5.3 63.1 32.1 5.7
61.0 42.0 5.2 58.2 41.4 5.5
55.9 50.4 5.0 52.9 49.0 5.4
55.1 51.0 5.0 52.8 48.8 5.4

CONDENSER AIR ENTERING Deg. F


95
105
Capacity
Capacity
Tot
Tot
MBtuh
MBtuh
Sys
Sys
Kw
Kw
Tot
Sen
Tot
Sen
37.9
18.4 3.7
36.4
17.7 3.9
34.2
22.7 3.6
32.4
21.8 3.8
30.5
26.5 3.4
28.9
25.4 3.6
29.8
27.0 3.4
28.7
25.6 3.6
38.5
19.2 3.8
37.1
18.6 4.0
34.9
24.2 3.7
33.1
23.3 3.9
31.3
28.4 3.5
29.9
26.7 3.7
31.2
28.3 3.5
29.9
26.7 3.7
38.9
19.9 3.8
37.5
19.4 4.1
25.6 3.7
35.5
33.6
24.8 4.0
32.3
29.3 3.7
31.0
27.7 3.9
32.3
29.3 3.7
31.0
27.7 3.9
46.8
20.4 4.3
42.4
19.6 4.6
42.1
25.1 4.2
37.8
24.2 4.4
37.6
29.4 4.0
33.7
28.2 4.2
36.7
30.0 3.9
33.4
28.3 4.2
47.5
21.2 4.4
43.2
20.6 4.7
43.1
26.8 4.3
38.6
25.9 4.6
38.6
31.5 4.1
34.8
29.6 4.3
38.4
31.4 4.1
34.8
29.6 4.3
48.0
22.1 4.5
43.7
21.5 4.8
28.4 4.4
43.8
39.1
27.5 4.6
39.8
32.5 4.3
36.1
30.7 4.5
39.8
32.5 4.3
36.1
30.7 4.5
58.7
29.0 5.8
54.1
27.9 6.0
52.9
35.8 5.6
48.2
34.4 5.8
47.2
41.8 5.4
43.0
40.2 5.5
46.1
42.7 5.3
42.6
40.4 5.5
59.7
30.3 5.9
55.1
29.3 6.2
54.1
38.2 5.8
49.2
36.9 6.0
48.4
44.9 5.5
44.5
42.2 5.7
48.3
44.7 5.5
44.5
42.2 5.7
60.3
31.4 6.0
55.8
30.6 6.3
40.4 5.9
55.0
50.0
39.1 6.1
50.0
46.3 5.7
46.1
43.7 5.9
50.0
46.3 5.7
46.1
43.7 5.9

115
Capacity
MBtuh
Tot Sen
34.0 16.9
30.0 20.9
26.8 23.9
26.8 24.0
34.6 17.8
30.6 22.4
28.1 25.1
28.1 25.1
35.0 18.7
31.0 23.8
29.1 26.0
29.1 26.0
39.6 18.7
35.0 23.2
31.3 26.6
31.3 26.6
40.3 19.7
35.6 24.8
32.7 27.8
32.7 27.8
40.8 20.7
36.1 26.4
33.9 28.8
33.9 28.8
50.6 26.7
44.6 33.1
39.9 37.8
39.9 37.8
51.4 28.1
45.5 35.4
41.8 39.6
41.8 39.6
52.0 29.5
46.1 37.6
43.3 41.0
43.3 41.1

Tot
Sys
Kw
4.2
4.0
3.8
3.8
4.3
4.1
3.9
3.9
4.4
4.2
4.1
4.1
4.9
4.7
4.5
4.5
5.0
4.8
4.6
4.6
5.1
4.9
4.8
4.8
6.4
6.1
5.8
5.8
6.6
6.3
6.0
6.0
6.7
6.4
6.2
6.2

120
Capacity
MBtuh
Tot
Sen
17.0
8.5
15.0 10.5
13.4 12.0
13.4 12.0
17.3
8.9
15.3 11.2
14.0 12.5
14.0 12.5
17.5
9.3
15.5 11.9
14.6 13.0
14.6 13.0
19.8
9.4
17.5 11.6
15.6 13.3
15.6 13.3
20.1
9.9
17.8 12.4
16.3 13.9
16.4 13.9
20.4 10.3
18.0 13.2
17.0 14.4
17.0 14.4
25.3 13.4
22.3 16.5
20.0 18.9
20.0 18.9
25.7 14.1
22.7 17.7
20.9 19.8
20.9 19.8
26.0 14.7
23.0 18.8
21.6 20.5
21.7 20.5

Tot
Sys
Kw
4.4
4.1
3.9
3.9
4.4
4.2
4.1
4.1
4.5
4.3
4.2
4.2
5.1
4.8
4.6
4.6
5.2
4.9
4.7
4.7
5.3
5.0
4.9
4.9
6.7
6.3
6.0
6.0
6.8
6.4
6.2
6.2
6.9
6.6
6.4
6.4

Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.

15

38HK/HQ

Matching 38HK with Free Stand

Typical Wiring Schematic 38HK 18-36- 60Hz

38HK/HQ

220-240V/1Ph 24V Control

220-240V/1Ph 220V Control

16

Typical Wiring Schematic 38HK- 48-70- 60Hz

38HK/HQ

220V/1Ph 24V Control

220V/1Ph 220V Control

17

Typical Wiring Schematic 38HK- 48-70- 60Hz Cont

38HK/HQ

220V/3Ph 24V Control

220V/3Ph 220V Control

18

38HK/HQ

Typical Wiring Schematic Heat Pump 38HQ18-24

19

Application data

38HK/HQ

Unit selection
Select equipment to match or be slightly less
than anticipated peak load. This provides better
humidity control, fewer unit cycles, and less
part-load operation.
For units used in spaces with high sensible loads,
base equipment selection on unit sensible load,
not on total anticipated load. Adjust for
anticipated room wet bulb temperature to avoid
under sizing equipment.
When selecting equipment that has outdoor air
introduced into the unit, determine the mix
conditions of room air and outdoor air at design
conditions. The cooling capacity tables in this
literature are based on 80 F edb. To select the
proper equipment, adjust for actual dry-bulb and
wet-bulb conditions with the required outdoor
air.

Unit mounting
Unit leveling For reliable operation, units
should be level in all planes.
Clearance Provide adequate clearance for
airflow. See dimensional drawings for proper
clearances. The condensing units are designed
for free-blow application. Air inlets and outlets
should not be restricted. Outdoor fan external
static pressure available is less than 0.1 in. wg.
Unit location Units may be wall mounted, pad
mounted at ground level, roof mounted, or
mounted on or under a deck or patio. Be sure
that water from roof does not drain directly onto
the unit. If 38 Series condensing units are
mounted near a wall, the condenser air should
discharge away from the wall. This will provide
inherent coil protection and the best possible
sound and airflow performance.
Winter start The use of a winter start control
may extend the operation range (generally to 35
F or 40 F). Winter start bypasses the lowpressure switch for 3 minutes.
Crankcase heater Units with low ambient
control should be equipped with crankcase
heaters to prevent refrigerant migration during
compressor off cycle.

20

Refrigerant lines
General refrigerant line sizing:
1. All charges, line sizing, and capacities are
based on runs of 25 ft. For runs over 25 ft,
consult the appendix A.
NOTE: The minimum line length should be 10 ft.
MAXIMUM LINE LENGTHS
UNIT

MAXIMUM
EQUIVALENT
FT

MAXIMUM LIFT
FAN COIL
BELOW
CONDENSING
UNIT

MAXIMUM LIFT
FAN COIL
ABOVE
CONDENSING
UNIT

38HK

50

30*

30*

*Maximum distance permitted is 30 ft from lowest


system component to highest system component. For
longer line application please refer to appendix A.

2. Refrigerant lines should not be buried in the


ground. If it is necessary to bury the lines, not
more than 36 in. should be buried. Provide a
minimum 6 in. vertical rise to the service valves
to prevent refrigerant migration.
3. The refrigerant lines must be insulated. Use a
minimum of 1/2-in. thick insulation. Closed-cell
insulation is recommended in all applications.
4. Special consideration should be given to
isolating interconnecting tubing from the building
structure. Isolate the tubing so that vibration or
noise is not transmitted into the structure.
5. The 38 Series system charge is based on rated
performance and 25 ft of line.
6. For the supply and return lines, check physical
data.
SYSTEM OPERATING CONDITIONS
OPERATING LIMITS
TEMPERATURE CONDITIONS
Maximum Cooling Ambient (F)
Minimum Cooling Ambient (F) (without
accessory low-ambient kit)
Minimum Cooling ambient (F) (with accessory
low-ambient kit)

LIMITS
125
55
35

Saturated Suction Temperature Range


Minimum (F) Maximum (F)

20 55

Saturated Condensing Temperature Range


Minimum (F) Maximum (F)

60 150

Maximum Compressor Discharge


Temperature (F)
Minimum Discharge Superheat (F)
NOTE: For system controls see Electrical Data.

275
60

Controls
Unit operation
The indoor blower starts according to the
normal fan coil unit sequence of operation.
The control relay (in the outdoor unit) initiates
operation of a cooling cycle for the
compressor. As the set point at the fan coil is
satisfied, its individual signal to the 38HK unit
stops.
38 Series outdoor condensing unit The
outdoor unit is equipped with a control that
monitors the indoor fan coil cooling request.
Unit malfunction Each unit is equipped
with a high-pressure switch (HPS), a low
pressure switch (LPS),
Compressor over current protection is
achieved by an internal line break overload,
which automatically resets when the motor
temperature cools to a satisfactory level.

38HK/HQ

NOTE: AUTO fan mode is used as the unit


operation example for ALL fan coil units in
this section. Contact your local Carrier dealer
for operation information in other fan modes.
Fan coil units Duct free fan coil units have
a self-contained control system that determines
the set point for fan coil operation, fan mode
operation, and heating mode operation (if
provided). The un-ducted fan coil and ducted
fan coil units are equipped with a thermostat.
For ducted fan coils the field installed
thermostat determines the set point for fan
mode operation, and electric heat operation (if
provided).
On a call for cooling operation by a single fan
coil unit, a signal is sent to the 38H outdoor
unit and energizes a control relay.

21

38HK/HQ

Appendix
Long-Line Guideline.

Reference:
Catalog No. 513-868

22

LONG-LINE GUIDELINE

REQUIRED FOR
LOW-AMBIENT APPLICATIONS
(BELOW 55F)

REQUIRED FOR
LONG-LINE
APPLICATIONS*
(OVER 50 FT)

REQUIRED FOR
SEA COAST
APPLICATIONS
(WITHIN 2 MILES)

Yes
Yes
Yes
No

Yes
No
No
No

No
No
No
No

Yes

Yes

No

Low Ambient Controller,


MotorMaster Control,
or
Low-Ambient Pressure Switch

Yes

No

No

Wind Baffle
Coastal Filter
Support Feet

See Low-Ambient Instructions


No
Recommended

No
No
No

No
Yes
Recommended

Liquid-Line Solenoid Valve


or
Hard-Shutoff TXV

No

See Long-Line
Application
Guideline

No

Ball-Bearing Fan Motor


Isolation Relay

Yes
Yes**

No
No

No
No

ACCESSORY

Crankcase Heater
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay

38HK/HQ

Table 1 REQUIRED FIELD INSTALLED


ACCESSORIES FOR AIR CONDITIONERS AND HEAT PUMP

*For tubing line sets between 50 and 175 ft, refer to Residential Split-System Long-Line Application Guideline.
Only when low-pressure switch is used.
Required for Low-Ambient Controller (full modulation feature) and MotorMaster control only.
** Required on Heat Pumps only.

This Long-Line Application Guideline applies


to all Carrier residential air conditioner and
heat pump split systems that have a nominal
capacity of 18,000 to 60,000 Btuh. This
guideline provides required system changes
and accessories necessary for any residential
product having piping requirements greater
than 50 ft or installations where indoor unit is
located above outdoor unit.
This guideline is intended to cover applications
outside the standard Installation Instructions.
This guideline is for standard, single-speed
products. For applications involving 2-speed
products, refer to Step 6 first.
NOTE: The presale literature for outdoor unit
must be referred to in conjunction with this
guideline.
Step 1Approved Systems
Any
residential
indoor/outdoor
unit
combination listed in the outdoor unit presale
literature is an approved system, EXCEPT the
following:
Indoor coils with capillary-metering devices
All equipment less than nominal 18,000 Btuh

All 1/4-in. and 3/16in. liquid-line


applications
Any indoor furnace coil/fan coil not listed in
outdoor unit presale literature
Any application which has interconnecting
tubing with an equivalent length greater than
175 ft
Step 2Interconnecting Tubing Sizing
Table 2 lists recommended interconnecting
vapor-line diameters for equivalent total-line
lengths. All residential split systems installed
in long-line applications must use only 3/8-in.
liquid lines. Equivalent line length equals the
linear length (measured) of interconnecting
vapor tubing plus losses due to elbows. (See
Table 3 and Fig. 3.) Liquid lines larger than
3/8-in. OD greatly increase charge quantity of
the system. Excessive charge increases risk of
migration and compressor damage. Table 2
provides the estimated percentage of nominal
cooling-capacity losses based on the standard,
required vapor line size versus what is selected
for the long-line application. Since the vapor
line is the discharge line in heating mode,
losses are minimal.

23

38HK/HQ

Calculate the linear length of vapor tube


required, adding any losses for the total
number of elbows for application. (See Table
6.) Using this equivalent length, select desired
vapor-line size from Table 2. Subtract the
nominal percentage loss from outdoor-unit
presale-literature Detailed Cooling Capacities
data for the given indoor/outdoor combination.
Reference all notes of Table 2.
NOTE:
When
specifying
vapor-line
insulation, be aware of the following standard
practice:
All standard accessory-tubing kits are supplied
with 3/8-in. insulation on vapor line.
For minimal capacity loss in long-line
application, 1/2-in. insulation should be
specified.
For reference only, the close cell insulation
material specified for accessory tubing kits is a
compound of vinyl, neoprene, or nitrile blends
of these polymers. Performance requirements
include thermal range of 0 F to 200F (-17.8
C to 93 C) and a maximum thermal
conductivity of 0.28.
NOTE: Special consideration must be given to
isolating interconnecting tubing from building
structure. Isolate tubing so that vibration or
noise is not transmitted into structure.
Step 3Metering Device Sizing
The metering device for a long-line application
must be flexible enough to compensate for
frictional losses due to long refrigerant lines
and installed system design (indoor coil above
or below outdoor unit.) The piston or TXV
provides such flexibility.
The piston should be changed for both indoor
coil and outdoor heat pump unit, depending on
system configuration and line length. Tables 4
and 5 provide necessary changes for a given
application.
Use Tables 4 and 5 when selecting correct
piston size. Outdoor unit presale literature
must be consulted to determine metering
devices specified for standard applications.
After determining standard application piston
size(s), refer to Tables 4 and 5 as they relate to
system design (outdoor unit above or below
indoor unit) per equivalent length of tubing.
NOTE: If total equivalent horizontal length is
100 ft or longer, both indoor and outdoor
pistons must be increased 1 full piston size, in
addition to changes required by Tables 4 and 5.
After finding appropriate change in piston
size, add or subtract the change from original
piston number. If piston size is decreased,
round new piston number down to nearest
common piston number found in Table 6. If
piston size is increased, round new piston

24

number up to nearest common piston number


found in Table 6.
EXAMPLE:
An 042 size heat pump is 75 ft above an 042 size
fan coil. The 042 size heat-pump presale literature
specifies a size 80 indoor piston and size 63 outdoor
piston. To establish correct indoor piston size for a
75 ft vertical separation, refer to Table 4. For a 75 ft
equivalent line length, the piston change is -5.
Therefore subtract 5 from the original indoor piston
size of 80: 80 5 = 75
Table 6 provides common piston sizes. In this
instance, 75 is not listed, therefore round DOWN to
next piston size, which would be 74. To establish
correct outdoor piston size for a 75 ft vertical
separation, refer to Table 5. For a 75 ft equivalent
line length, the piston change is +4. Therefore add 4
to the original outdoor piston size of 63: 63 + 4 = 67
Since 67 is listed in Table 6, that is the piston which
should be used. If a 67 size piston were not listed, it
would be necessary to round UP to next piston size.

Step 4Liquid-Line Solenoid And


Tubing Configuration
There are 2 types of liquid-line solenoids: 1 for
single-flow applications and the other for biflow applications. The purpose of having 2
solenoids is to minimize the valve internalpressure drop in accordance with refrigerant
flow direction and liquid migration to the
compressor. The bi-flow solenoid is designed
to have minimal refrigerant-pressure drop in
either flow direction, which makes it suitable
for heat pump usage. Refer to Table 7 for
liquid-line solenoid kit part numbers.
NOTE: When installing a liquid-line solenoid,
the system may require a minimum 60-va lowvoltage transformer.
Each type of solenoid has an indicator flow
arrow stamped on the valve body. When
solenoid is closed (not energized) and pressure
is applied in direction of flow arrow, complete
shutoff occurs. If pressure is applied against
direction of flow arrow, leakage through valve
occurs. When determining proper installation
of valve within liquid line, 2 considerations
must be made:
1. Direction of flow arrow
2. Where solenoid is installed in system.
TXVs can only be substituted for liquid-line
solenoids in singleflow air conditioning
systems. Bi-flow TXVs allow liquid migration
to coldest point during off cycles, which could
allow liquid into compressor. Fig. 2 through 5
detail proper installation of liquid-line solenoid
and provide applications where TXVs may be
substituted. Reference all notes of the
appropriate figures.

EXAMPLE:
To calculate additional charge required for a 25ft
line set: 25 ft 15 ft
= 10 ft X 0.6 oz/ft = 6 oz of additional charge

The rating-plate charge of a given outdoor unit


is for a standard application of 15 ft of
interconnecting tubing. The rating-plate charge
can be found on outdoor unit-rating plate or in
outdoor unit-presale literature. Long-line
applications do not require additional oil
charge.

38HK/HQ

Step 5Charging Information


Weigh in appropriate refrigerant charge, then
use the standard practices of superheatcharging method for piston applications and
subcooling-charging
method
for TXV
applications to confirm correct charge. The
standard charging methods can be found on
outdoor unit-information plate, in unit
Installation Instructions, or in the Service
Manual. Since total system charge is increased
for long-line applications, it may be necessary
to calculate the additional refrigerant charge.
Since long-line applications only involve 3/8in. liquid lines, the additional refrigerant
charge required is 0.6 oz of Refrigerant 22 (R22) per ft of 3/8-in. liquid line over 15 ft.

Table 2 Estimated Percentage of Nominal Cooling-Capacity Losses*


UNIT NOMINAL
SIZE (BTUH)
18,000
24,000
30,000
36,000
42,000

48,000
60,000

LONG-LINE
VAPOR-LINE
DIAMETER (IN.)**
5/8
3/4
5/8
3/4
5/8
3/4
3/4
7/8
3/4
7/8
1-1/8
3/4
7/8
1-1/8
7/8
1-1/8

EQUIVALENT LINE LENGTH (FT)


50

75

100

125

150

175

5
1
6
0
6
2
7
2
7
3
0
10
4
0
7
1

7
3
9
1
8
3
10
4
10
4
0
14
6
0
9
2

9
4
13
1
10
4
14
6
13
6
1
18
7
1
11
2

12
5
16
2
13
5
17
8
17
7
1
22
9
1
14
3

12
5
19
3
15
6
21
10
20
8
2
NR
11
2
16
3

14
7
22
4
17
7
NR
11
23
10
2
NR
13
2
19
4

*The estimated percentage of cooling capacity that must be subtracted from the Detailed Cooling Capacities data specified in outdoor
unit-presale literature for any given indoor/outdoor combination.
**Vapor-line diameter that may be selected for a long-line application. If smaller vapor lines are selected but not specified within the
table, large capacity losses will occur and defrost capabilities will be reduced. If larger vapor lines are selected but not specified within
the table, refrigerant oil return will be impaired due to velocity losses.
N/RNot recommended due to excessive loss of capacity.

Step 62Speed Applications


Outdoor units may be connected to indoor
section using accessory tubing package or
field-supplied refrigerant grade tubing or
correct size and condition. In long-line
applications, 2speed units are handled
basically the same way as the single-speed
units. There are 2 major differences:
1. For tubing up to 100 ft: Liquid tube
diameters and refrigerant connection diameters
for all sizes are 3/8 in.

Vapor tube diameter for the 036 and 048 is 7/8


in.; 060 is 11/8
Vapor refrigerant connection diameter for all
sizes is 7/8 in.
DO
NOT
INSTALL
EQUIVALENT
INTERCONNECTING TUBING LENGTHS
GREATER THAN 100 FT.
2. Do not increase or decrease tubing sizes.
For other applications see the previous sections
under Long-Line Guidelines.

25

38HK/HQ

90 STD

45 STD

Fig.1Tube Bend Losses


Table 3Fitting Losses in Equivalent Ft
TUBE SIZE OD
(IN.)
5/8
3/4
7/8
1-1/8

26

A
1.6
1.8
2.0
2.6

REFERENCE DIAGRAM IN FIG. 1


B
1.0
1.2
1.4
1.7

C
0.8
0.9
1.0
1.3

Table 4 - Calculation of Indoor Piston No.


OUTDOOR UNIT ABOVE INDOOR
FT
0-25
26-50
51-75
76-100
101-125
126-150

PISTON CHANGE
0
-3
-5
-7
-9
-10

38HK/HQ

OUTDOOR UNIT BELOW INDOOR


FT
0-25
26-50

PISTON CHANGE
0
+4

Table 5 Calculation of Outdoor Piston No.


OUTDOOR UNIT ABOVE INDOOR
FT
0-50
51-75
76-100
101-125
126-150

PISTON CHANGE
0
+4
+6
+8
+10
OUTDOOR UNIT BELOW INDOOR

FT
0-50

PISTON CHANGE
0

Table 6 Common Piston Sizes


ACCURATER

35

38

40

42

46

49
51
52

55
57
59
61

63

CHATLEFF
32
33
35
36
37
38
39
40
41
42
43
45

47
49
51
52
53
55
57
59
61
62
63

ACCURATER
65
67

70

73

76
78
80

82
84
86
88

90

93
96
98
101
104
109

CHATLEFF
65
67
68
70
71
73
74
76
78
80
81
82
84
86
88
89
90
92
93
96
98
101
104

Table 7Liquid-Line Solenoid Kit Part Numbers


TYPE OF VALVE
Single Flow
Bi-Flow

PART NO.
KAALS0101LLS
KHALS0101LLS

27

38HK/HQ

175' MAX.

GROUND LEVEL

Note: For Rotary Compressor,


maximum length is 105'.
BASEMENT

Fig. 2Application with Air Conditioner Installed in a Horizontal Configuration

175' MAX.

GROUND LEVEL

Note: For Rotary Compressor,


maximum length is 105'.
BASEMENT

Fig. 3Application with Heat Pump Installed in a Horizontal Configuration

28

38HK/HQ
TRAP

50' MAX.

HEAT PUMP ONLY

GROUND LEVEL

Note: For Rotary Compressor,


maximum height is 30'.

Fig. 4-Application with Air Conditioner or Heat Pump Installed with Indoor Unit above Outdoor Unit

29

38HK/HQ

HEAT PUMP ONLY

150' MAX.

Note: For Rotary Compressor,


maximum height is 90'.

Fig. 5Application with Air Conditioner or Heat Pump Installed Above Indoor Unit

30

38HK/HQ

Notes

31

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations

2011

38HK-03 PD 60HZ