Beruflich Dokumente
Kultur Dokumente
38HK12-70
38HQ18-24
38HQ18-24
Condensing Units - 60Hz
1Cond
to 6 Nominal Tons
Product Data
The 38H Series Energy-Efficient Split condensing units incorporate innovative technology to provide
reliable cooling performance. Built into these units are features most desired by the industry.
Features/Benefits
Designed especially for high ambient
environment.
EER (Energy Efficiency Ratio) ratings
of up to 10.0.
The small footprint coupled with the
horizontal airflow design means that the
38H Series units can be installed within
200 mm (8 in). of an outside wall, on a
roof, balcony, or deck.
Electrical Range
All units are offered in 220-240v single
phase. Three-phase units are available
from 48 through 70 sizes in 220v.
Wide Range of Sizes
The 38H Series is available in 7
nominal sizes from 1.5 through 6 to
meet the needs of residential and light
commercial applications.
Application Versatility
The unit can be combined with a wide
variety of evaporator coils and blower
packages to provide quiet, dependable
comfort. Unit can be installed on a roof or
at ground level.
Easy
access
for
service
and
maintenance
A single panel provides immediate
access to the isolated compressor and
control compartment, allowing a service
technician access to check unit operation
without losing condenser airflow. Coils
can be cleaned quickly from the outside.
Secure operation
If security is an issue, outdoor and
indoor units are connected only by
refrigerant piping and wiring to prevent
intruders
from
crawling
through
ductwork. The 38H Series units can be
installed 8 in. away from outside walls,
protecting coils from vandals and severe
weather.
38HK/HQ
Fast installation
Carriers compact systems take
only a few hours to install
only wire and piping need to be
run. The fast and easy
installation ensures minimal
disruption to customers in the
home or workplace. This Carrier
advantage
is
especially
beneficial in retrofit situations.
External Service Valves
Service valves are brass,
front seating type. The 38H
Series has flare connections,
units
are
the
only
dedicated commercial units
with all safety features
standard to ensure high
performance and lasting
reliability under the most
demanding situations. For
example, start capacitors
ensure dependable startups, especially during low
voltage conditions (down to
187 v). High-pressure and
low-pressure
safety
switches are standard
Table of contents
Features/Benefits.
ModelNumber Nomenclature..
Physical Data.
Combination Ratings
Air Deflector Accessory ..
Base Unit Dimensions..
Electrical Data
Detailed Performance Data 42TX Matching.
Detailed Performance Data FB4A Matching
Detailed Performance Data Ceiling Cassette Matching.
Detailed Performance Data Free Stand Matching...
Typical Wiring Schematic.
Application Data
Controls...
Appendix Long Line Guide Line.
Page.
1
3
3
4
5
6-7
8
9,10
11,12
13,14
15
16-19
20
21
22
18
- 00
Type
38Air-Cooled
Condenser
Factory Reference
Design Series
Series
38HK/HQ
Voltage
3 220160
5 220360
2 380360
Condenser Type
K-Cool
Q- Heat Pump
Fin Type
S- Standard Bare Fins
P- Pre-Coated Blue Fins
Compressor
C- Reciprocating
R- Rotary - Super Tropical
Application
D: Ducted application
FB4A or 42TX
24 Volt compressor contactor
U: Un Ducted application/Decorative
Ceiling Cassette, Hi wall,--etc.
220 Volt compressor contactor
Physical Data
UNIT 38H
NOMINAL CAPACITY (Tons)
OPERATING WEIGHT (lb)
SHIPPING DIMENSIONS (in) (W X H X D)
COMPRESSOR
Cool Only
Heat Bump
REFRIGERANT TYPE
METERING DEVICE
Ducted Application
Un-ducted Application
FINISH
OUTDOOR FAN
RPM/CFM
Diameter, No. Blades
Motor Horsepower,
COIL DATA
Face Area (sq ft)
Tubes
Fins
FPI
REFRIGERANT LINES **
Connection Type
Liquid Line
Vapour Line
Max Length
Max Lift
Max Drop
* Sweat adapter kit is provided for 7/8 tube size.
** For long line application see Appendix.
18
1.5
123
24
30
2
2.5
139
154
37 x 29.7 x 16.1
36
3
161
48
60
70
4.0
5.0
6.0
211
227
253
50.4 X 40.2 X 30
Reciprocating
--
Rotary
R22
Capillary Tube
6.3
Smooth
15
5/8 in.
12.05
Helical grooved
Aluminium, Double Wavy
17
17
15
12
Flare
3/8 inch
3/4 in.
50 ft
30 ft
30 ft
14
7/8 inch*
Combination ratings
Nominal
Cap.
MBtuh
18
38HK/HQ
24
30
36
48
60
70
Nominal
Cap.
MBtuh
18
24
30
Indoor Type
Indoor Model
Cassette
Console
High Wall
High Wall
High Wall
Ducted Split
Ducted Split
Cassette
Console
High Wall
High Wall
High Wall
Ducted Split
Ducted Split
Cassette
Console
High Wall
Ducted Split
Ducted Split
Cassette
Cassette
Console
High Wall
Free Stand
Free Stand
Ducted Split
Ducted Split
Cassette
Cassette
Free Stand
Ducted Split
Ducted Split
Ducted Split
Free Stand
Ducted Split
Ducted Split
Ducted Split
Ducted Split
40KMC018-3N-IU
42VMC18-3C
42KPL020-3
42KHC018-3
42EGC018-3
FB4ASNF018
42TX-018-301
40KMC024-3N-IU
42VMC24-3C
42KPL025-3
42KHD024-3
42EGC024-3
F4ASNF024
42TX-024-301
40KMC036-3
42VMC30-3C
42XP090C3
42TX-030-301
FB4ASNF030
42KMC-048-3N-IU
40KMC036-3N-IU
42VMC36-3C
42XP100C3
42SD6B
42HD6B
42TX-036-301
FB4ASNF036
40KMC048-3N-IU
40KMC048-3EN-IU
42SD6B
42TX-048-301
42MX-048-301
FB4ASNF048
42SD7B
42TX-060-301
42MX-060-301
FB4ASNF060
FB4ASNF070
Outdoor Model
Cap.
Btu/hr
CFM
Input Watts
E.E.R.
38HKR018US
38HKR018US
38HKR018UP
38HKR018UP
38HKR018US
38HKR018DS
38HKR018DS
38HKC024US
38HKR024US
38HKR024UP
38HKR024UP
38HKR024US
38HKC024DS
38HKC024DS
38HKC030US
38HKC030US
38HKC030US
38HKC030DS
38HKC030DS
38HKC036US
38HKC036US
38HKC036US
38HKC036US
38HKC036US
38HKC036US
38HKC036DS
38HKC036DS
38HKC048US
38HKC036US
38HKC048US
38HKC048DS
38HKC048DS
38HKC048DS
38HKC060US
38HKC060DS
38HKC060DS
38HKC060DS
38HKS070DS
18,000
18,000
19,000
18,000
18,000
19,000
19,000
21,750
21,000
22,500
21,750
21,750
23,000
23,000
27,500
29,000
27,500
30,500
30,500
35,000
35,000
32,500
35,000
35,500
35,500
35,000
35,800
41,000
41,000
44,000
44,000
47,500
46,500
55,000
56,500
58,300
56,800
68,750
425
440
550
550
550
650
650
450
530
650
650
650
650
650
750
675
730
800
1150
975
975
765
830
800
800
1100
1200
975
750
900
1400
1633
1500
1500
1600
1820
1650
1850
2.00
2.10
2.18
2.00
2.00
2.30
2.30
2.40
2.45
2.39
2.40
2.40
2.60
2.60
3.20
3.20
3.20
3.70
3.70
3.80
3.80
3.60
3.80
3.75
3.75
3.65
4.00
4.23
4.23
4.90
4.51
5.00
5.33
5.88
5.8
6.10
6.48
7.2
8.9
8.4
8.7
8.9
8.9
8.1
8.1
8.9
8.5
9.4
8.9
8.9
8.8
8.8
8.8
9.0
8.8
8.2
8.2
9.0
9.0
9.0
9.0
9.5
9.5
9.6
9.0
9.7
9.7
8.9
9.7
9.5
8.8
9.3
9.8
9.6
8.8
9.6
HEAT PUMP*
Indoor Type
Console
High Wall
High Wall
High Wall
Console
High Wall
High Wall
High Wall
Console
Indoor model
42VMC18-3H
42QPL020-3
42QHC018-3
42EGQ018-3
42VMC24-3H
42QPL025-3
42QHD024-3
42EGQ024-3
42VMC30-3H
LEGEND
CFM Cubic Feet Per Minute
EER Energy Efficiency Ratio
* as per SASO 2681/2007 standard
COOLING ONLY*
Outdoor model
CFM
38HQR018US
38HQR018UP
38HQR018UP
38HQR018US
38HQR024US
38HQR024UP
38HQR024UP
38HQR024US
38HQC030US
440
550
550
550
530
650
650
650
680
CAP.
Btu/hr
16,000
18,000
18,000
18,000
21,500
22,000
21,000
21,000
28,000
COOLING MODE
Input
E.E.R.
Watts
1.90
8.3
2.00
8.9
1.90
9.5
1.90
9.5
2.40
8.8
2.24
9.8
2.40
8.7
2.30
9.0
3.10
9.0
HEATING MODE
CAP.
Input
Btu/hr
Watts
4,900
1.70
4,750
1.63
5,100
1.70
5,000
1.70
5,300
1.86
5,700
1.83
5,500
1.86
5,250
1.84
8,500
2.70
COP
2.80
3.00
3.00
2.90
2.85
3.10
2.95
2.85
3.20
NOTES:
Cooling Standard: 80.6F db, 66.2F wb indoor entering-air temperature and 95.0 F
db air entering outdoor unit.
Heating Standard: 68 F db, 59 F wb indoor entering-air temperature and 44.6 F db
air entering outdoor unit.
38HK/HQ
Note:
This accessory is used only with 38HK048-070
38HK/HQ
048-070
Ft-in.
mm
Ft-in.
mm
Ft-in.
mm
Ft-in.
mm
Ft-in.
mm
Ft-in.
mm
Ft-in.
mm
Ft-in.
mm
3-1316
944.6
3-8916
1131.9
1-5116
433.4
1-6716
468.3
2-612
774.7
1-758
498.5
1-758
498.5
2-558
752.5
38HK/HQ
UNIT 38H
NOTES:
1. Required clearances: with coil facing wall
allow 8 in. minimum clearance on coil side and
coil end, and 3 ft minimum clearance on
compressor end and fan side.
2. Dimensions in [ ] are in millimeters.
Electrical Data
Size
18
38HK/HQ
24
30
36
48
60
70
Size
18
24
Cool Only
Power
Voltage
Supply
Min
Max
Compressor
FLA
LRA
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/1/60
220/3/60
220/1/60
220/3/60
220/1/60
220/3/60
220/1/60
220/3/60
380/3/60
220/3/60
380/3/60
9.6
9.1
9.6
9.6
12.5
10.1
12.5
12.5
13.5
13.5
14.4
14.4
18.5
11.4
18.5
11.4
26.6
15.0
26.6
15.0
10.4
16.0
8.3
Outdoor Model
38HKC018US30
38HKR018US30
38HKC018UP30
38HKC018DS30
38HKC024US30
38HKR024US30
38HKC024UP30
38HKC024DS30
38HKC030US30
38HKC030DS30
38HKC036US30
38HKC036DS30
38HKC048US30
38HKC048US50
38HKC048DS30
38HKC048DS50
38HKC060US30
38HKC060US50
38HKC060DS30
38HKC060DS50
38HKC060DS20
38HKS070DS50
38HKS070DS20
55.0
40.0
55.0
55.0
60.0
53.0
60.0
60.0
82.0
82.0
88.0
88.0
118.0
78.0
118.0
78.0
178.0
114.0
178.0
114.0
55.0
150.0
75.0
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
Heat Pump
Power
Voltage
Supply
Min
Max
Compressor
FLA
LRA
Fan
FLA
220/1/60
220/1/60
220/1/60
220/1/60
9.1
9.1
10.1
10.1
Outdoor Model
38HQR018US30
38HQR018UP30
38HQR024US30
38HQR024UP30
LEGEND
FLA Full Load Amps
LRA Locked Rotor Amps
RLA Rated Load Amps
MCA Minimum Circuit Amps
MOCP Maximum Over current Protection Amps
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
198
342
198
342
198
198
198
198
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
242
418
242
418
Fan
FLA
242
242
242
242
40.0
40.0
53.0
53.0
0.9
0.9
0.9
0.9
18
24
30
36
CFM EWB
72
Evaporator
67
450 Air
62
57
72
67
550
62
57
72
67
650
62
57
72
67
450
62
57
72
67
550
62
57
72
67
650
62
57
72
67
600
62
57
72
67
700
62
57
72
67
800
62
57
72
67
800
62
57
72
67
950
62
57
72
67
1100
62
57
MBtuh
Sen
22.6 10.9
20.9 13.6
18.9 16.0
Capacity
18.0 16.8
22.9
Tot 11.3
21.3 14.3
19.3 17.1
18.8 17.6
23.1 11.6
21.5 15.0
19.7 18.0
19.5 18.2
26.6 12.5
24.6 15.5
22.3 18.2
21.2 19.2
27.0 12.9
25.1 16.3
22.8 19.5
22.2 20.1
27.2 13.2
25.4 17.1
23.3 20.5
23.0 20.8
34.9 15.4
32.3 19.1
29.2 22.5
27.7 23.7
35.3 15.9
32.9 20.2
29.9 24.0
29.1 24.8
35.6 16.4
33.3 21.1
30.5 25.3
30.1 25.6
40.7 18.6
37.6 23.0
34.0 27.1
32.4 28.5
41.2 19.2
38.3 24.3
34.9 29.0
33.9 29.9
41.6 19.7
38.8 25.5
35.6 30.5
35.1 30.9
85
Tot
Sys
Kw
2.0
2.0
1.9
1.9
2.1
2.0
1.9
1.9
2.1
2.1
2.0
2.0
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.3
2.3
2.2
2.2
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
2.9
2.8
2.8
3.1
3.0
3.0
2.9
3.2
3.1
3.0
3.0
3.3
3.2
3.1
3.1
MBtuh
Tot
Sen
21.8
10.7
19.9
13.2
17.8
15.5
Capacity
17.2
16.1
22.1
11.1
20.3
14.0
18.3
16.6
17.9
16.8
22.3
11.5
20.6
14.8
18.7
17.5
18.6
17.5
25.7
12.2
23.4
15.1
21.0
17.6
20.2
18.3
26.0
12.7
23.9
16.0
21.5
18.9
21.2
19.1
26.3
13.1
24.2
16.8
22.1
20.0
22.0
19.9
33.6
15.0
30.7
18.6
27.5
21.8
26.5
22.6
34.1
15.6
31.3
19.7
28.2
23.3
27.7
23.6
34.4
16.1
31.8
20.8
28.9
24.6
28.8
24.5
39.2
18.1
35.8
22.4
32.0
26.3
30.9
27.3
39.8
18.8
36.5
23.8
32.9
28.1
32.3
28.5
40.2
19.5
37.1
25.1
33.7
29.7
33.6
29.6
95
Tot
Sys
Kw
2.2
2.1
2.0
2.0
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.4
2.3
2.3
2.2
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
3.0
2.9
2.8
2.8
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.4
3.3
3.2
3.1
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
105
Tot
Tot
MBtuh
MBtuh
Sys
Sys
Tot
Sen
Kw
Tot
Sen
Kw
20.7 10.4 2.3 19.7
10.0 2.6
CONDENSER AIR ENTERING Deg. F
18.7 12.8 2.2 17.6
12.3 2.5
16.7 15.0 2.1 15.7
14.4 2.3
Capacity
Capacity
16.3 15.3 2.1 15.5
14.4 2.3
21.1 10.8 2.4 20.1
10.5 2.6
19.1 13.7 2.3 17.9
13.2 2.5
17.1 16.0 2.2 16.2
15.1 2.4
17.0 16.0 2.2 16.2
15.1 2.4
21.3 11.2 2.4 20.3
10.9 2.7
19.0 14.4 2.3 18.2
14.0 2.6
17.7 16.5 2.3 16.8
15.6 2.5
17.7 16.5 2.3 16.8
15.6 2.5
24.4 11.8 2.6 23.5
11.4 2.7
22.0 14.6 2.5 20.9
14.0 2.6
19.7 17.0 2.4 18.6
16.4 2.5
19.2 17.4 2.4 18.5
16.4 2.5
24.8 12.3 2.6 23.9
11.9 2.8
22.5 15.6 2.6 21.4
15.0 2.7
20.2 18.3 2.4 19.3
17.2 2.6
20.1 18.2 2.4 19.3
17.2 2.6
25.1 12.8 2.7 24.2
12.5 2.9
22.9 16.5 2.6 21.7
15.9 2.8
20.8 18.8 2.5 20.0
17.8 2.7
20.8 18.8 2.5 20.0
17.8 2.7
32.0 14.6 3.2 29.1
14.0 3.3
28.9 18.0 3.1 25.9
17.3 3.2
25.7 21.0 3.0 23.1
20.2 3.0
25.2 21.5 3.0 22.9
20.3 3.0
32.5 15.2 3.3 29.7
14.7 3.4
29.5 19.2 3.2 26.5
18.5 3.3
26.4 22.5 3.1 23.9
21.2 3.2
26.3 22.5 3.1 23.9
21.2 3.2
32.9 15.8 3.4 30.0
15.4 3.5
30.0 20.3 3.3 26.9
19.7 3.4
27.3 23.3 3.2 24.8
22.0 3.3
27.3 23.3 3.2 24.8
22.0 3.3
37.4 17.6 3.6 35.3
16.9 3.8
33.7 21.7 3.5 31.4
20.9 3.7
30.0 25.4 3.3 28.0
24.4 3.5
29.3 25.9 3.3 27.8
24.5 3.5
38.0 18.3 3.7 35.9
17.8 3.9
34.4 23.2 3.6 32.1
22.3 3.8
30.8 27.2 3.4 29.0
25.5 3.6
30.7 27.1 3.4 29.0
25.6 3.6
38.4 19.0 3.7 36.4
18.6 4.0
35.0 24.5 3.6 32.6
23.7 3.9
31.8 28.1 3.6 30.0
26.5 3.8
31.8 28.1 3.6 30.0
26.5 3.8
115
MBtuh
Tot
Sen
18.4
9.5
16.3 11.8
14.5 13.5
Capacity
14.5 13.5
18.7 10.1
16.6 12.6
15.2 14.1
15.2 14.1
19.0 10.5
18.0 13.4
15.8 14.7
15.8 14.7
21.9 10.9
19.4 13.5
17.3 15.4
17.3 15.4
22.3 11.5
19.7 14.4
18.1 16.1
18.1 16.1
22.6 12.0
20.0 15.3
18.8 16.7
18.8 16.7
27.2 13.4
24.0 16.6
21.5 19.0
21.5 19.0
27.7 14.1
24.5 17.8
22.5 19.9
22.5 19.9
28.0 14.8
24.8 18.9
23.3 20.6
23.3 20.6
33.0 16.2
29.1 20.0
26.0 22.9
26.0 22.9
33.5 17.1
29.6 21.5
27.2 24.0
27.2 24.0
33.9 17.9
30.0 22.8
28.2 24.9
28.2 24.9
120
Tot
Sys
Kw
2.7
2.6
2.5
2.5
2.8
2.7
2.6
2.6
2.8
2.7
2.6
2.6
2.9
2.8
2.7
2.7
3.0
2.8
2.7
2.7
3.0
2.9
2.8
2.8
3.5
3.3
3.2
3.2
3.7
3.5
3.4
3.4
3.7
3.6
3.5
3.5
4.1
3.9
3.7
3.7
4.2
4.0
3.8
3.8
4.3
4.1
4.0
4.0
MBtuh
Tot
Sen
9.2
4.8
8.1
5.9
7.3
6.8
Capacity
7.3
6.8
9.4
5.0
8.3
6.3
7.6
7.1
7.6
7.1
9.5
5.3
8.4
6.7
7.9
7.3
7.9
7.3
11.0
5.4
9.7
6.7
8.7
7.7
8.7
7.7
11.2
5.7
9.9
7.2
9.1
8.1
9.1
8.1
11.3
6.0
10.0
7.7
9.4
8.4
9.4
8.4
13.6
6.7
12.0
8.3
10.7
9.5
10.7
9.5
13.8
7.1
12.2
8.9
11.2
9.9
11.2
10.0
14.0
7.4
12.4
9.5
11.6
10.3
11.7
10.3
16.5
8.1
14.5
10.0
13.0
11.5
13.0
11.5
16.8
8.5
14.8
10.7
13.6
12.0
13.6
12.0
17.0
8.9
15.0
11.4
14.1
12.4
14.1
12.4
Tot
Sys
Kw
2.8
2.7
2.6
2.6
2.9
2.7
2.6
2.6
2.9
2.8
2.7
2.7
3.0
2.9
2.7
2.7
3.1
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.6
3.4
3.3
3.3
3.8
3.6
3.5
3.5
3.9
3.7
3.6
3.6
4.2
4.0
3.8
3.8
4.3
4.1
4.0
4.0
4.4
4.2
4.1
4.1
38HK/HQ
75
Nom
Cap.
Mbtuh
38HK/HQ
Nom
Cap.
Mbtuh
48
60
Evaporator
Air
75
Capacity
MBtuh
CFM EWB
Sen
Tot
72
51.1 24.3
67
47.3 30.1
1100
62
42.8 35.5
57
40.7 37.4
72
51.8 25.1
67
48.2 31.8
1250
62
43.8 37.9
57
42.6 39.1
72
52.3 25.8
67
48.8 33.3
1400
62
44.7 40.0
57
44.1 40.5
72
63.8 30.3
67
59.0 37.6
1300
62
53.4 44.3
57
50.8 46.6
72
64.6 31.3
67
60.1 39.7
1450
62
54.7 47.3
57
53.1 48.8
72
65.2 32.2
67
60.9 41.6
1600
62
55.8 49.8
57
55.0 50.5
85
Tot
Sys
Kw
3.9
3.8
3.7
3.6
4.0
3.9
3.8
3.7
4.1
4.0
3.9
3.8
5.0
4.9
4.7
4.7
5.1
5.0
4.8
4.8
5.2
5.1
5.0
4.9
Capacity
MBtuh
Tot
Sen
49.3 23.7
45.0 29.4
40.3 34.4
38.9 35.7
50.0 24.7
45.9 31.1
41.4 36.8
40.6 37.3
50.5 25.5
46.6 32.8
42.4 38.9
42.2 38.7
61.5 29.6
56.1 36.6
50.2 42.9
48.5 44.5
62.4 30.8
57.3 38.8
51.6 45.8
50.7 46.5
63.0 31.8
58.1 40.9
52.8 48.5
52.6 48.3
Tot
Sys
Kw
4.2
4.0
3.9
3.9
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
5.4
5.2
5.0
5.0
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
Capacity
MBtuh
Tot
Sen
47.0 23.0
42.3 28.4
37.8 33.2
36.9 33.9
47.7 24.0
43.3 30.3
38.8 35.6
38.6 35.4
48.3 24.9
44.0 32.1
40.0 36.7
40.0 36.7
58.6 28.7
52.8 35.4
47.1 41.4
46.0 42.2
59.5 29.9
54.0 37.8
48.3 44.4
48.2 44.2
60.2 31.1
54.9 40.0
49.9 45.8
49.9 45.8
Tot
Sys
Kw
4.4
4.3
4.1
4.1
4.5
4.4
4.2
4.2
4.6
4.5
4.4
4.4
5.7
5.5
5.3
5.2
5.8
5.7
5.5
5.5
6.0
5.8
5.7
5.7
Capacity
MBtuh
Tot Sen
45.3 22.1
40.4 27.3
36.0 31.9
35.7 32.0
46.2 23.3
41.2 29.2
37.2 33.4
37.2 33.4
46.7 24.3
41.8 31.0
38.6 34.7
38.6 34.7
56.6
27.6
50.5
34.1
45.0
39.8
44.6
40.0
57.7
29.0
51.5
36.5
46.5
41.7
46.5
41.7
58.4
30.3
52.3
38.7
48.2
43.2
48.2 43.2
Tot
Sys
Kw
4.7
4.5
4.3
4.3
4.8
4.6
4.4
4.4
4.9
4.7
4.6
4.6
6.4
6.2
5.9
5.9
6.6
6.4
6.1
6.1
6.7
6.5
6.3
6.3
115
Capacity
MBtuh
Tot
Sen
42.3 21.2
37.4 26.2
33.4 30.0
33.4 30.0
43.0 22.3
38.1 28.1
35.0 31.4
35.0 31.4
43.6 23.4
38.6 29.8
36.2 32.6
36.3 32.6
52.9 26.4
46.7 32.7
41.8 37.4
41.8 37.4
53.8 27.8
47.6 35.0
43.7 39.1
43.7 39.2
54.4 29.2
48.2 37.2
45.3 40.6
45.3 40.6
120
Tot
Sys
Kw
5.0
4.8
4.5
4.5
5.1
4.9
4.7
4.7
5.2
5.0
4.8
4.8
6.9
6.5
6.2
6.2
7.0
6.7
6.4
6.4
7.1
6.9
6.7
6.7
Capacity
MBtuh
Tot Sen
21.2 10.6
18.7 13.1
16.7 15.0
16.7 15.0
21.5 11.2
19.0 14.0
17.5 15.7
17.5 15.7
21.8 11.7
19.3 14.9
18.1 16.3
18.1 16.3
26.5 13.2
23.4 16.3
20.9 18.7
20.9 18.7
26.9 13.9
23.8 17.5
21.8 19.6
21.8 19.6
27.2 14.6
24.1 18.6
22.6 20.3
22.7 20.3
Tot
Sys
Kw
5.2
4.9
4.7
4.7
5.3
5.0
4.8
4.8
5.4
5.1
5.0
5.0
7.1
6.7
6.4
6.4
7.3
6.9
6.7
6.7
7.4
7.1
6.9
6.9
48
60
Evaporator
Air
CFM EWB
72
67
1250
62
57
72
67
1440
62
57
72
67
1550
62
57
72
67
1450
62
57
72
67
1600
62
57
72
67
1800
62
57
75
85
Capacity
Tot Capacity
MBtuh
MBtuh
Sys
Tot Sen Kw Tot Sen
52.9 24.3 4.3 51.0 23.7
48.9 30.1 4.2 46.5 29.4
44.2 35.5 4.1 41.6 34.4
42.1 37.4 4.0 40.2 35.7
53.6 25.1 4.4 51.7 24.7
49.8 31.8 4.3 47.5 31.1
45.3 37.9 4.2 42.8 36.8
44.1 39.1 4.1 42.0 37.3
54.1 25.8 4.5 52.2 25.5
50.5 33.3 4.4 48.2 32.8
46.2 40.0 4.3 43.8 38.9
45.6 40.5 4.2 43.6 38.7
67.8 32.6 5.2 65.4 31.9
62.7 40.5 5.1 59.6 39.4
56.7 47.7 5.0 53.4 46.2
53.9 50.2 4.9 51.5 47.9
68.7 33.7 5.4 66.3 33.1
63.9 42.7 5.2 60.8 41.8
58.1 50.9 5.1 54.8 49.4
56.5 52.5 5.0 53.8 50.1
69.3 34.7 5.5 66.9 34.2
64.7 44.8 5.4 61.7 44.1
59.2 53.7 5.2 56.1 52.2
58.4 54.4 5.2 55.9 52.0
Tot
Sys
Kw
4.6
4.5
4.3
4.3
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
5.6
5.5
5.3
5.2
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
Capacity
MBtuh
Tot Sen
48.6 23.0
43.8 28.4
39.0 33.2
38.1 33.9
49.4 24.0
44.8 30.3
40.1 35.6
39.9 35.4
49.9 24.9
45.5 31.8
41.4 36.7
41.4 36.7
62.2 30.9
56.1 38.1
50.0 44.6
48.9 45.5
63.3 32.3
57.4 40.7
51.4 47.8
51.2 47.6
64.0 33.5
58.3 43.1
53.0 49.3
53.0 49.3
Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.
10
Tot
Sys
Kw
4.9
4.8
4.6
4.5
5.0
4.9
4.7
4.7
5.1
5.0
4.9
4.9
6.0
5.8
5.6
5.5
6.1
6.0
5.7
5.7
6.3
6.1
5.9
5.9
Capacity
MBtuh
Tot
Sen
45.2
22.1
40.2
27.3
35.9
31.9
35.5
32.0
46.0
23.3
41.1
29.2
37.1
33.4
37.1
33.4
46.6
24.3
41.7
31.0
38.5
34.7
38.5
34.7
55.9
29.7
49.8
36.7
44.4
42.8
44.0
43.0
56.9
31.3
50.8
39.3
45.9
44.9
45.9
44.9
57.6
32.6
51.6
41.7
47.6
46.6
47.6
46.6
Tot
Sys
Kw
5.1
4.9
4.7
4.6
5.2
5.0
4.8
4.8
5.3
5.1
5.0
5.0
6.2
6.0
5.7
5.7
6.3
6.2
5.9
5.9
6.5
6.3
6.1
6.1
115
Capacity
MBtuh
Tot Sen
42.2 21.2
37.2 26.2
33.3 30.0
33.3 30.0
42.9 22.3
37.9 28.1
34.8 31.4
34.8 31.4
43.4 23.4
38.5 29.8
36.1 32.6
36.1 32.6
52.2 28.4
46.1 35.2
41.2 40.3
41.2 40.3
53.1 30.0
46.9 37.7
43.1 42.2
43.1 42.2
53.7 31.4
47.6 40.1
44.7 43.7
44.7 43.7
120
Tot
Sys
Kw
5.4
5.2
4.9
4.9
5.5
5.3
5.1
5.1
5.6
5.4
5.3
5.3
6.6
6.3
6.0
6.0
6.7
6.4
6.2
6.2
6.9
6.6
6.4
6.4
Capacity
MBtuh
Tot
Sen
21.1
10.6
18.6
13.1
16.6
15.0
16.7
15.0
21.4
11.2
19.0
14.0
17.4
15.7
17.4
15.7
21.7
11.7
19.2
14.9
18.1
16.3
18.1
16.3
26.1
14.2
23.0
17.6
20.6
20.2
20.6
20.2
26.5
15.0
23.5
18.9
21.5
21.1
21.6
21.1
26.9
15.7
23.8
20.0
22.3
21.9
22.4
21.9
Tot
Sys
Kw
5.6
5.3
5.1
5.1
5.7
5.4
5.2
5.2
5.8
5.6
5.4
5.4
6.9
6.5
6.2
6.2
7.0
6.6
6.4
6.4
7.1
6.8
6.6
6.6
75
MBtuh
Sen
22.5 11.6
20.8
14.4
Capacity
18.8 16.9
17.9
Tot 17.8
22.7 12.0
21.2 15.2
19.2 18.1
18.7 18.6
23.0 12.3
21.4 15.9
19.6 19.0
19.4 19.3
27.8 13.4
25.7 16.6
23.2 19.6
22.1 20.6
28.1 13.8
26.2 17.5
23.8 20.9
23.1 21.5
28.4 14.2
26.5 18.3
24.3 22.0
23.9 22.3
36.0 19.1
33.4 23.7
30.1 27.9
28.7 29.3
36.5 19.7
34.0 25.0
30.9 29.8
30.0 30.7
36.8 20.3
34.4 26.2
31.5 31.4
31.1 31.8
42.3 21.2
39.1 26.3
35.4 31.0
33.7 32.7
42.9 21.9
39.9 27.8
36.3 33.1
35.2 34.2
43.2 22.6
40.4 29.1
37.0 34.9
36.5 35.4
85
Tot
Sys
Kw
2.0
2.0
1.9
1.9
2.1
2.0
2.0
2.0
2.1
2.1
2.0
2.0
2.3
2.3
2.2
2.2
2.4
2.3
2.3
2.3
2.4
2.4
2.3
2.3
3.2
3.2
3.1
3.0
3.3
3.2
3.2
3.1
3.4
3.3
3.2
3.2
3.5
3.4
3.3
3.3
3.6
3.5
3.4
3.4
3.7
3.6
3.5
3.5
MBtuh
Tot Sen
21.7 11.3
19.8
14.0
Capacity
17.7 16.4
17.1 17.0
22.0 11.8
20.2 14.8
18.2 17.5
17.8 17.8
22.2 12.1
20.5 15.6
18.6 18.5
18.5 18.5
26.8 13.1
24.4 16.2
21.9 18.9
21.1 19.6
27.2 13.6
24.9 17.2
22.5 20.2
22.1 20.5
27.4 14.0
25.3 18.1
23.0 21.4
22.9 21.3
34.8 18.6
31.7 23.1
28.4 27.0
27.4 28.0
35.3 19.4
32.4 24.5
29.1 28.9
28.6 29.3
35.6 20.0
32.8 25.8
29.9 30.5
29.7 30.4
40.8 20.8
37.2 25.7
33.3 30.1
32.1 31.2
41.4 21.6
38.0 27.2
34.2 32.1
33.6 32.6
41.8 22.3
38.5 28.7
35.0 34.0
34.9 33.9
95
Tot
Sys
Kw
2.2
2.1
2.0
2.0
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.5
2.5
3.5
3.4
3.3
3.2
3.6
3.5
3.4
3.4
3.6
3.5
3.5
3.5
3.7
3.6
3.5
3.5
3.8
3.7
3.6
3.6
3.9
3.8
3.7
3.7
105
Tot
Tot
MBtuh
MBtuh
Sys
Sys
Tot
Sen
Kw
Tot
Sen
KwF
CONDENSER AIR ENTERING Deg.
20.6
11.0
2.3
20.1 10.6 2.7
18.6
13.5
2.3
18.0
13.0 2.6
Capacity
Capacity
16.6
15.8
2.2
16.0 15.2 2.5
16.2
16.1
2.1
15.9 15.3 2.5
21.0
11.4
3.0
20.5 11.1 2.8
19.0
14.4
2.3
18.3 13.9 2.7
17.0
17.0
2.2
16.6 15.9 2.6
17.0
16.9
2.2
16.5 15.9 2.6
21.2
11.9
2.4
20.8 11.6 2.8
19.3
15.3
2.4
18.6 14.8 2.7
17.6
17.5
2.3
17.2 16.5 2.6
17.6
17.5
2.3
17.1 16.5 2.6
25.5
12.7
2.7
24.1 12.2 2.9
23.0
15.6
2.6
21.5 15.0 2.8
20.5
18.3
2.5
19.1 17.6 2.6
20.0
18.6
2.5
19.0 17.6 2.6
25.9
13.2
2.7
24.5 12.8 2.9
23.5
16.7
2.7
21.9 16.1 2.9
21.0
19.6
2.6
19.8 18.4 2.7
21.0
19.5
2.6
19.8 18.4 2.7
26.2
13.7
2.8
24.8 13.4 3.0
23.9
17.7
2.7
22.2 17.1 2.9
21.7
20.2
2.7
20.5 19.1 2.8
21.7
20.2
2.7
20.5 19.1 2.8
33.1
18.1
3.7
31.2 17.4 3.9
29.8
22.3
3.6
27.8 21.4 3.8
26.6
26.1
3.5
24.8 25.0 3.6
26.0
26.6
3.4
24.6 25.2 3.5
33.6
18.9
3.8
31.8 18.3 4.0
30.5
23.8
3.7
28.4 23.0 3.9
27.3
27.9
3.6
25.7 26.3 3.7
27.2
27.8
3.6
25.7 26.2 3.7
34.0
19.6
3.9
32.2 19.1 4.1
31.0
25.2
3.8
28.8 24.4 3.9
28.2
28.8
3.7
26.6 27.2 3.8
28.2
28.8
3.7
26.6 27.2 3.8
38.9
20.1
4.0
37.9 19.4 4.2
35.0
24.8
3.9
33.7 23.9 4.0
31.2
29.0
3.7
30.1 27.9 3.8
30.5
29.6
3.7
29.8 28.0 3.8
39.5
21.0
4.1
38.6 20.3 4.3
35.8
26.5
4.0
34.4 25.6 4.1
32.1
31.1
3.8
31.1 29.2 3.9
31.9
31.0
3.8
31.1 29.2 3.9
39.9
21.8
4.2
39.1 21.3 4.3
36.4
28.0
4.1
35.0 27.1 4.2
33.1
32.1
4.0
32.3 30.3 4.1
33.1
32.1
4.0
32.2 30.3 4.1
115
MBtuh
Tot
Sen
19.3
10.1
17.1
12.5
Capacity
15.3
14.3
15.3
14.3
19.7
10.6
17.4
13.4
16.0
15.0
16.0
15.0
19.9
11.1
17.6
14.2
16.6
15.5
16.6
15.5
23.4
11.7
20.6
14.4
18.4
16.5
18.4
16.5
23.7
12.3
21.0
15.5
19.3
17.3
19.3
17.3
24.0
12.9
21.3
16.4
20.0
17.9
20.0
17.9
29.2
16.6
25.8
20.6
23.0
23.6
23.0
23.6
29.7
17.5
26.3
22.0
24.1
24.6
24.1
24.6
30.0
18.4
26.6
23.4
25.0
25.6
25.0
25.6
35.4
18.5
31.2
22.9
27.9
26.2
27.9
26.2
36.0
19.5
31.8
24.5
29.2
27.4
29.2
27.4
36.4
20.4
32.3
26.1
30.3
28.5
30.3
28.5
120
Tot
Sys
Kw
2.9
2.8
2.6
2.6
2.9
2.8
2.7
2.7
2.9
2.8
2.7
2.7
3.1
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.2
3.1
3.0
3.0
4.1
3.9
3.8
3.8
4.2
4.0
3.9
3.9
4.3
4.1
4.0
4.0
4.4
4.2
4.0
4.0
4.5
4.3
4.2
4.2
4.6
4.4
4.3
4.3
MBtuh
Tot Sen
18.3 9.7
16.1
12.1
Capacity
14.6 13.6
14.6 13.6
18.6 10.3
16.4 13.0
15.2 14.3
15.2 14.3
18.9 10.8
16.6 13.8
15.8 14.8
15.8 14.8
22.1 11.2
19.4 14.0
17.6 15.8
17.6 15.8
22.5 11.9
19.8 15.0
18.4 16.5
18.4 16.5
22.8 12.5
20.1 16.0
19.1 17.1
19.1 17.1
27.7 16.0
24.3 20.0
22.0 22.5
22.0 22.5
28.1 17.0
24.7 21.4
23.0 23.5
23.0 23.5
28.5 17.8
25.1 22.8
23.8 24.3
23.8 24.3
33.5 17.9
29.4 22.2
26.6 25.0
26.6 25.0
34.1 18.9
30.0 23.8
27.9 26.2
27.9 26.2
34.5 19.9
30.4 25.3
28.9 27.1
28.9 27.1
Tot
Sys
Kw
3.0
2.8
2.7
2.7
3.1
2.9
2.8
2.8
3.0
2.9
2.8
2.8
3.2
3.0
2.9
2.9
3.2
3.1
3.0
3.0
3.3
3.2
3.1
3.1
4.3
4.1
3.9
3.9
4.4
4.2
4.0
4.0
4.5
4.3
4.2
4.2
4.6
4.4
4.2
4.2
4.7
4.5
4.3
4.3
4.8
4.6
4.5
4.5
11
38HK/HQ
to
Nom
Cap.
MBtuh CFM,
BP EWB
Evapora
r Air72
67
525
62
57
72
67
18
600
62
57
72
67
675
62
57
72
67
550
62
57
72
67
24
625
62
57
72
67
700
62
57
72
67
1000
62
57
72
67
30
1150
62
57
72
67
1300
62
57
72
67
1050
62
57
72
67
36
1200
62
57
72
67
1350
62
57
38HK/HQ
Nom
Cap.
MBtuh
48
60
Evaporator
Evaporator
AirAir
CFM EWB
72
67
1300
62
57
72
67
1500
62
57
72
67
1700
62
57
72
67
1450
62
57
72
67
1650
62
57
72
67
1850
62
57
1300
70
1500
1700
72
67
62
57
72
67
62
57
72
67
62
57
75
Capacity
Capacity
MBtuh
Tot
Tot Sen
54.9 28.7
50.8 35.6
46.0 42.0
43.7 44.1
55.7 29.7
51.8 37.6
47.1 44.8
45.8 46.2
56.2 30.5
52.4 39.4
48.0 47.2
47.4 47.8
67.1 32.3
62.1 40.1
56.1 47.3
53.4 49.7
68.0 33.4
63.3 42.3
57.5 50.4
55.9 52.1
68.6 34.4
64.0 44.3
58.7 53.2
57.9 53.9
Tot
Sys
Kw
4.6
4.5
4.4
4.3
4.7
4.6
4.5
4.4
4.8
4.7
4.6
4.6
5.7
5.5
5.4
5.3
5.8
5.7
5.5
5.5
5.9
5.8
5.7
5.6
79.2
79.2 37.7
37.76.5
79.2 46.7
37.7 6.5
73.3
73.3 46.76.3
73.3 55.1
46.7 6.3
66.2
66.2 55.16.1
66.2 57.9
55.1 6.1
63.0
63.0 57.96.1
80.2
38.9
80.2 38.96.6
74.6
74.6 49.3
49.36.5
67.9
67.9 58.8
58.86.3
67.9 60.7
58.8 6.3
66.0
66.0 60.76.2
66.0 40.0
60.7 6.2
80.9
80.9 40.06.8
80.9 51.7
40.0 6.8
75.5
75.5 51.76.6
75.5 62.0
51.7 6.6
69.2
69.2 62.06.5
6.5
68.3
68.3 62.8
62.86.4
6.4
85
Capacity
Capacity
MBtuh
Tot
Sen
53.0
28.1
48.4
34.7
43.3
40.6
41.8
42.2
53.8
29.1
49.3
36.8
44.4
43.4
43.7
44.1
54.2
30.1
50.0
38.8
45.5
45.9
45.3
45.8
64.7
31.6
59.1
39.1
52.9
45.8
51.0
47.5
65.7
32.8
60.3
41.5
54.3
48.9
53.3
49.6
66.3
33.9
61.1
43.7
55.6
51.7
55.4
51.6
76.4
76.4
76.4
69.7
69.7
69.7
62.3
62.3
62.3
60.2
60.2
77.4
77.4
71.1
71.1
64.0
64.0
64.0
62.9
62.9
62.9
78.2
78.2
78.2
72.1
72.1
72.1
65.6
65.6
65.6
65.3
5.3
5.3
CONDENSER
AIR
ENTERING
FF
CONDENSER
AIR
ENTERINGDeg.
Deg.
95
105
Capacity
Capacity
Tot
Capacity Tot
Capacity Tot
MBtuh
MBtuh
Sys
Sys
Sys
Kw Tot
Sen
Kw
Tot
Sen Kw
5.0 50.5
27.2
5.3
47.6
26.2 5.4
4.8 45.5
33.6
5.1
42.5
32.3 5.2
4.6 40.6
39.2
4.9
37.8
37.7 4.9
4.6 39.6
40.0
4.9
37.5
37.9 4.9
5.1 51.3
28.4
5.4
48.5
27.5 5.5
35.8
5.3
4.9 46.5
43.3
34.5 5.3
4.8 41.6
42.0
5.1
39.1
39.5 5.1
4.8 41.5
41.9
5.1
39.1
39.5 5.1
5.2 51.9
29.5
5.5
49.1
28.7 5.6
5.0 47.3
37.9
5.4
44.0
36.7 5.4
4.9 43.0
43.4
5.2
40.6
41.0 5.3
4.9 43.0
43.4
5.2
40.5
40.9 5.3
6.1 61.6
30.6
6.5
59.4
29.5 6.6
5.9 55.6
37.8
6.3
52.9
36.4 6.4
5.7 49.6
44.2
6.1
47.1
42.4 6.1
5.7 48.4
45.1
6.0
46.7
42.6 6.1
6.2 62.6
32.0
6.7
60.5
31.0 6.8
40.3
6.5
6.1 56.8
54.0
38.9 6.6
5.9 50.9
47.4
6.2
48.8
44.5 6.3
5.9 50.7
47.2
6.2
48.7
44.5 6.3
6.4 63.3
33.2
6.8
61.2
32.4 6.9
6.2 57.7
42.7
6.6
54.8
41.3 6.7
6.0 52.5
48.9
6.4
50.5
46.1 6.5
6.0 52.5
48.9
6.4
50.5
46.1 6.5
36.8
36.87.0
36.8 6.8
7.0
45.5
45.5
45.5 6.5
6.8
53.3
53.3
53.3 6.5
6.5
55.3
55.3
38.2
7.1
38.2
48.3
48.36.9
57.0
57.06.7
57.0 6.7
6.7
57.8
57.8
57.8 7.3
6.7
39.5
39.5
39.5 7.1
7.3
50.9
50.9
50.9 6.9
7.1
60.3
60.3
60.3 6.9
6.9
60.1
60.1
60.1 6.9
72.7
72.7
72.7
65.5
65.5
65.5
58.5
58.5
58.5
57.1
57.1
73.9
73.9
73.9
67.0
67.0
60.0
60.0
60.0
59.8
59.8
59.8
74.7
4.7
4.7
68.1
68.1
68.1
61.9
61.9
61.9
61.9
35.7
35.7
35.7
44.0
44.0
44.0
51.5
51.5
51.5
52.5
52.5
37.2
37.2
47.0
47.0
55.2
55.2
55.2
55.0
55.0
55.0
38.7
38.7
38.7
49.8
49.8
49.8
57.0
57.0
57.0
57.0
57.0
12
7.4
7.4
7.2
7.2
6.9
6.9
6.8
7.6
7.4
7.4
7.1
7.1
7.1
7.1
7.8
7.8
7.6
7.6
7.4
7.4
7.4
68.6
68.6
68.6
61.2
61.2
61.2
54.5
54.5
54.5
54.0
54.0
69.9
69.9
62.4
56.4
56.4
56.4
56.4
56.4
56.4
70.8
70.8
70.8
63.4
63.4
58.5
58.5
58.4
58.4
58.4
34.3
34.3 8.0
34.3 7.7
8.0
42.4
42.4
42.4 7.3
7.7
49.4
49.4
49.4 7.3
7.3
49.7
49.7
36.1
8.1
36.1
45.3
45.3 7.9
51.9
51.9 7.5
51.9 7.5
7.5
51.8
51.8
51.8 8.3
7.5
37.7
37.7
37.7 8.0
8.3
48.1
48.1
53.8
7.8
53.8
7.8
53.7
53.7 7.8
53.7 7.8
115
Capacity
Capacity
MBtuh
Tot Sen
44.5 25.0
39.3 31.0
35.1 35.5
35.1 35.5
45.2 26.4
39.5 33.2
36.7 37.1
36.7 37.1
45.8 27.6
40.6 35.2
38.1 38.5
38.1 38.5
55.5 28.2
49.0 34.9
43.8 39.9
43.8 40.0
56.4 29.7
49.8 37.4
45.8 41.8
45.8 41.8
57.1 31.1
50.5 39.7
47.5 43.3
47.5 43.3
Tot
Sys
Kw
5.7
5.5
5.2
5.2
5.9
5.6
5.4
5.4
6.0
5.7
5.6
5.6
7.1
6.7
6.4
6.4
7.2
6.9
6.6
6.6
7.4
7.1
6.9
6.9
64.1
64.1 32.9
32.98.5
64.1 40.7
32.9 8.5
56.6
56.6 40.78.1
56.6 46.5
40.7 8.1
50.6
50.6 46.57.7
50.6 46.6
46.5
50.6
50.6 46.67.7
65.2
34.6
65.2 34.68.6
57.6
57.6 43.6
43.68.3
52.9
52.9 48.7
48.78.0
52.9 48.7
48.7 8.0
52.9
52.9 48.78.0
52.9 36.3
48.7 8.0
66.0
66.0 36.38.8
66.0 46.3
36.3 8.8
58.5
58.5 46.38.5
58.5 50.5 8.2
8.5
54.9
54.9 50.5
54.9 50.5
50.5 8.2
54.9
54.9 50.58.2
54.9 50.5 8.2
120
Capacity
Capacity
MBtuh
Tot Sen
42.2 24.1
37.0 30.1
33.5 33.8
33.5 33.8
42.9 25.5
37.7 32.2
35.0 35.4
35.0 35.4
43.4 26.8
38.2 34.2
36.3 36.6
36.3 36.6
52.5 27.2
46.1 33.8
41.8 38.1
41.8 38.1
53.4 28.8
47.0 36.3
43.7 39.9
43.7 39.8
54.1 30.2
47.6 38.6
45.2 41.3
45.2 41.3
60.7
60.7 31.7
31.7
60.7 39.4
31.7
53.3
53.3 39.4
53.3 44.4
39.4
48.3
48.3 44.4
48.3
48.3 44.4
44.4
61.8
61.8 33.5
33.5
54.3
54.3 42.3
42.3
50.5
50.5 46.4
46.4
50.5 46.4
46.4
50.5
50.5 46.4
50.5 35.2
46.4
62.6
62.6 35.2
62.6 45.0
35.2
55.1
55.1 45.0
55.1 48.1
45.0
52.3
52.3 48.1
52.3
52.3 48.1
48.1
52.3
Tot
Sys
Kw
6.0
5.6
5.4
5.4
6.1
5.8
5.6
5.6
6.2
5.9
5.8
5.8
7.3
6.9
6.6
6.6
7.5
7.1
6.9
6.9
7.6
7.3
7.1
7.1
8.8
8.8
8.3
8.3
7.9
8.0
8.9
8.5
8.2
8.2
8.2
8.2
8.2
9.1
9.1
8.7
8.7
8.5
8.5
8.5
8.5
Notes:
1. Net Capacities shown include a deduction for evaporator fan
motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.
Nom
Cap.
Mbtuh
Evaporator
Air
CFM
300
18
375
425
325
24
400
450
570
36
Evap
Evap &
&
650
30
Cond
750
570
36
Evap
&
36
Cond
650
750
680
48
Evap
&
36
Cond
830
975
75
Capacity
MBtuh
EWB Tot Sen
72 20.9 9.1
67 19.4 11.2
62 17.5 13.2
57 16.6 13.9
72 21.2 9.4
67 19.7 11.9
62 17.9 14.1
57 17.4 14.6
72 21.4 9.6
67 20.0 12.4
62 18.3 14.9
57 18.0 15.1
72 26.7 12.7
67 24.7 15.8
62 22.4 18.6
57 21.3 19.5
72 27.1 13.1
67 25.2 16.6
62 22.9 19.8
57 22.3 20.5
72 27.3 13.5
67 25.5 17.4
62 23.4 20.9
57 23.1 21.2
72 32.0 13.5
67 29.6 16.7
62 26.7 19.7
57 25.4 20.7
72 32.4 13.9
67 30.1 17.6
62 27.4 21.0
57 26.6 21.7
72 32.7 14.3
67 30.5 18.5
62 27.9 22.2
57 27.6 22.4
72 34.9 14.0
67 32.3 17.4
62 29.2 20.5
57 27.7 21.6
72 35.3 14.5
67 32.9 18.4
62 29.9 21.9
57 29.1 22.6
72 35.6 14.9
67 33.3 19.2
62 30.5 23.1
57 30.1 23.4
72 37.2 16.2
67 34.4 20.1
62 31.1 23.7
57 29.6 24.9
72 37.7 16.7
67 35.1 21.2
62 31.9 25.3
57 31.0 26.1
72 38.0 17.2
67 35.5 22.2
62 32.5 26.6
57 32.08 26.99
Tot
Sys
Kw
1.8
1.8
1.7
1.7
1.9
1.8
1.8
1.8
1.9
1.9
1.8
1.8
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.3
2.3
2.2
2.2
2.7
2.7
2.6
2.6
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.1
3.1
3.0
3.0
3.1
3.0
2.9
2.9
3.2
3.1
3.0
3.0
3.2
3.2
3.1
3.06
85
Capacity
MBtuh
Tot Sen
20.2
8.9
18.4 10.9
16.5 12.8
15.9 13.3
20.5
9.2
18.8 11.6
16.9 13.7
16.6 13.9
20.7
9.5
19.1 12.2
17.3 14.5
17.3 14.4
25.8 12.4
23.5 15.4
21.1 18.0
20.3 18.7
26.2 12.9
24.0 16.3
21.6 19.2
21.2 19.5
26.4 13.3
24.4 17.2
22.1 20.3
22.1 20.3
30.8 13.2
28.1 16.3
25.2 19.1
24.3 19.8
31.3 13.7
28.7 17.3
25.8 20.4
25.4 20.7
31.6 14.1
29.1 18.2
26.5 21.6
26.4 21.5
33.6 13.7
30.7 17.0
27.5 19.9
26.5 20.6
34.1 14.2
31.3 18.0
28.2 21.2
27.7 21.5
34.4 14.7
31.8 18.9
28.9 22.5
28.8 22.4
35.9 15.8
32.7 19.6
29.3 22.9
28.3 23.8
36.4 16.4
33.4 20.8
30.1 24.5
29.6 24.9
36.7 17.0
33.9 21.9
30.8 25.9
30.70 25.83
Tot
Sys
Kw
2.0
1.9
1.9
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
2.0
2.4
2.3
2.2
2.2
2.4
2.4
2.3
2.3
2.5
2.4
2.4
2.4
2.9
2.9
2.8
2.7
3.0
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.2
3.1
3.0
3.0
3.3
3.2
3.1
3.1
3.3
3.3
3.2
3.2
3.3
3.2
3.1
3.1
3.4
3.3
3.2
3.2
3.5
3.4
3.3
3.28
Tot
Sys
Kw
2.5
2.4
2.2
2.2
2.5
2.4
2.3
2.3
2.6
2.4
2.4
2.4
3.0
2.9
2.7
2.7
3.1
2.9
2.8
2.8
3.1
3.0
2.9
2.9
3.6
3.4
3.2
3.2
3.6
3.5
3.4
3.4
3.7
3.6
3.5
3.5
3.9
3.7
3.5
3.5
4.0
3.8
3.7
3.7
4.1
3.9
3.8
3.8
4.1
3.9
3.7
3.7
4.2
4.0
3.9
3.9
4.3
4.1
4.0
4.00
120
Capacity
Tot
MBtuh
Sys
Tot Sen
Kw
8.6
3.9
2.6
7.6
4.9
2.4
6.8
5.6
2.3
6.8
5.6
2.3
8.8
4.2
2.6
7.7
5.2
2.5
7.1
5.9
2.4
7.1
5.9
2.4
8.9
4.4
2.7
7.8
5.6
2.5
7.4
6.1
2.5
7.4
6.1
2.5
10.8 5.5
3.1
9.6
6.9
2.9
8.5
7.8
2.8
8.5
7.9
2.8
11.0 5.8
3.2
9.7
7.3
3.0
8.9
8.2
2.9
8.9
8.2
2.9
11.1 6.1
3.2
9.9
7.8
3.1
9.3
8.5
3.0
9.3
8.5
3.0
13.1 5.9
3.7
11.5 7.3
3.5
10.3 8.3
3.3
10.3 8.3
3.4
13.3 6.2
3.8
11.8 7.8
3.6
10.8 8.7
3.5
10.8 8.7
3.5
13.5 6.5
3.9
11.9 8.3
3.7
11.2 9.0
3.6
11.2 9.0
3.6
14.3 6.1
4.0
12.6 7.6
3.8
11.3 8.7
3.7
11.3 8.7
3.7
14.5 6.4
4.1
12.8 8.1
3.9
11.8 9.1
3.8
11.8 9.1
3.8
14.7 6.8
4.2
13.0 8.6
4.0
12.2 9.4
3.9
12.2 9.4
3.9
15.5 7.1
4.3
13.7 8.7
4.0
12.2 10.0
3.9
12.3 10.0
3.9
15.8 7.4
4.3
14.0 9.4
4.1
12.8 10.5
4.0
12.8 10.5
4.0
16.0 7.8
4.4
14.1 9.9
4.2
13.3 10.9
4.1
13.30 10.86 4.13
13
38HK/HQ
Nom Cap.
Mbtuh
Evaporator
Air
CFM
38HK/HQ
680
48 Evap
&
48
Cond
830
975
EWB
72
67
62
57
72
67
62
57
72
67
62
57
75
Cap.
Tot Sen
47.3 20.8
43.7 25.9
39.5 30.5
37.6 32.1
47.9 21.5
44.5 27.3
40.5 32.5
39.4 33.6
48.3 22.1
45.1 28.6
41.3 34.3
40.8 34.7
Tot
Sys
3.63
3.54
3.44
3.40
3.72
3.63
3.53
3.50
3.81
3.72
3.62
3.60
85
Cap. MBtuh
Tot
Sen
45.6 20.4
41.6 25.2
37.2 29.5
35.9 30.6
46.2 21.2
42.4 26.7
38.2 31.5
37.6 32.0
46.7 21.9
43.1 28.1
39.1 33.4
39.0 33.2
Tot
Sys
3.91
3.80
3.66
3.62
3.98
3.89
3.77
3.75
4.07
3.96
3.86
3.86
Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.
14
Tot
Sys
4.76
4.53
4.32
4.32
4.85
4.64
4.46
4.46
4.94
4.75
4.61
4.61
120
Cap.
Tot Sen
36.4 17.3
32.1 21.4
28.7 24.5
28.7 24.5
37.0 18.2
32.7 22.9
30.0 25.6
30.0 25.6
37.4 19.1
33.2 24.3
31.1 26.5
31.2 26.5
Tot
Sys
4.94
4.66
4.45
4.46
5.02
4.76
4.60
4.60
5.12
4.89
4.77
4.77
Nom
Cap.
Mbtuh
Evaporator
Air
CFM
600
36
700
800
700
48
800
900
1000
60
1250
1500
EWB
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
75
85
Capacity Tot Capacity Tot
MBtuh
MBtuh
Sys
Sys
Tot Sen Kw Tot Sen Kw
41.3 19.4 3.2 39.8 18.9 3.5
38.2 24.0 3.1 36.3 23.4 3.4
34.5 28.3 3.0 32.5 27.4 3.2
32.8 29.8 3.0 31.4 28.5 3.2
41.8 20.0 3.3 40.4 19.7 3.5
38.9 25.4 3.2 37.0 24.9 3.4
35.4 30.2 3.1 33.4 29.3 3.3
34.4 31.2 3.1 32.8 29.8 3.3
42.2 20.6 3.4 40.7 20.3 3.6
39.4 26.6 3.3 37.6 26.2 3.5
36.1 31.9 3.2 34.2 31.0 3.4
35.6 32.3 3.2 34.1 30.9 3.4
50.9 21.5 3.7 49.1 21.0 4.0
47.1 26.7 3.7 44.8 26.0 3.9
42.6 31.4 3.6 40.1 30.4 3.8
40.5 33.0 3.5 38.7 31.6 3.7
51.6 22.2 3.8 49.8 21.8 4.1
48.0 28.1 3.7 45.7 27.6 4.0
43.6 33.5 3.6 41.2 32.5 3.9
42.4 34.6 3.6 40.5 33.0 3.9
52.1 22.8 3.9 50.3 22.5 4.2
48.6 29.5 3.8 46.4 29.0 4.1
44.5 35.4 3.7 42.2 34.4 4.0
43.9 35.8 3.7 42.0 34.3 4.0
63.9 30.6 5.0 61.7 29.9 5.4
59.2 38.0 4.9 56.3 37.0 5.3
53.5 44.8 4.8 50.3 43.3 5.1
50.9 47.1 4.7 48.6 45.0 5.0
64.8 31.7 5.2 62.5 31.1 5.5
60.2 40.1 5.0 57.4 39.3 5.4
54.8 47.8 4.9 51.7 46.3 5.2
53.3 49.3 4.9 50.8 47.0 5.2
65.4 32.5 5.3 63.1 32.1 5.7
61.0 42.0 5.2 58.2 41.4 5.5
55.9 50.4 5.0 52.9 49.0 5.4
55.1 51.0 5.0 52.8 48.8 5.4
115
Capacity
MBtuh
Tot Sen
34.0 16.9
30.0 20.9
26.8 23.9
26.8 24.0
34.6 17.8
30.6 22.4
28.1 25.1
28.1 25.1
35.0 18.7
31.0 23.8
29.1 26.0
29.1 26.0
39.6 18.7
35.0 23.2
31.3 26.6
31.3 26.6
40.3 19.7
35.6 24.8
32.7 27.8
32.7 27.8
40.8 20.7
36.1 26.4
33.9 28.8
33.9 28.8
50.6 26.7
44.6 33.1
39.9 37.8
39.9 37.8
51.4 28.1
45.5 35.4
41.8 39.6
41.8 39.6
52.0 29.5
46.1 37.6
43.3 41.0
43.3 41.1
Tot
Sys
Kw
4.2
4.0
3.8
3.8
4.3
4.1
3.9
3.9
4.4
4.2
4.1
4.1
4.9
4.7
4.5
4.5
5.0
4.8
4.6
4.6
5.1
4.9
4.8
4.8
6.4
6.1
5.8
5.8
6.6
6.3
6.0
6.0
6.7
6.4
6.2
6.2
120
Capacity
MBtuh
Tot
Sen
17.0
8.5
15.0 10.5
13.4 12.0
13.4 12.0
17.3
8.9
15.3 11.2
14.0 12.5
14.0 12.5
17.5
9.3
15.5 11.9
14.6 13.0
14.6 13.0
19.8
9.4
17.5 11.6
15.6 13.3
15.6 13.3
20.1
9.9
17.8 12.4
16.3 13.9
16.4 13.9
20.4 10.3
18.0 13.2
17.0 14.4
17.0 14.4
25.3 13.4
22.3 16.5
20.0 18.9
20.0 18.9
25.7 14.1
22.7 17.7
20.9 19.8
20.9 19.8
26.0 14.7
23.0 18.8
21.6 20.5
21.7 20.5
Tot
Sys
Kw
4.4
4.1
3.9
3.9
4.4
4.2
4.1
4.1
4.5
4.3
4.2
4.2
5.1
4.8
4.6
4.6
5.2
4.9
4.7
4.7
5.3
5.0
4.9
4.9
6.7
6.3
6.0
6.0
6.8
6.4
6.2
6.2
6.9
6.6
6.4
6.4
Notes:
1. Net Capacities shown include a deduction for evaporator fan motor heat.
2. Formulas:
Leaving db= Entering - Sensible Heat Cap./(1.09 x CFM)
Leaving wb= wb corresponding to air leaving coil (hwb)
h wb leaving = hwb entering - Total Cap(Btuh)/(4.5 X CFM)
3. Direct Interpolation Permissible. Do not extrapolate.
15
38HK/HQ
38HK/HQ
16
38HK/HQ
17
38HK/HQ
18
38HK/HQ
19
Application data
38HK/HQ
Unit selection
Select equipment to match or be slightly less
than anticipated peak load. This provides better
humidity control, fewer unit cycles, and less
part-load operation.
For units used in spaces with high sensible loads,
base equipment selection on unit sensible load,
not on total anticipated load. Adjust for
anticipated room wet bulb temperature to avoid
under sizing equipment.
When selecting equipment that has outdoor air
introduced into the unit, determine the mix
conditions of room air and outdoor air at design
conditions. The cooling capacity tables in this
literature are based on 80 F edb. To select the
proper equipment, adjust for actual dry-bulb and
wet-bulb conditions with the required outdoor
air.
Unit mounting
Unit leveling For reliable operation, units
should be level in all planes.
Clearance Provide adequate clearance for
airflow. See dimensional drawings for proper
clearances. The condensing units are designed
for free-blow application. Air inlets and outlets
should not be restricted. Outdoor fan external
static pressure available is less than 0.1 in. wg.
Unit location Units may be wall mounted, pad
mounted at ground level, roof mounted, or
mounted on or under a deck or patio. Be sure
that water from roof does not drain directly onto
the unit. If 38 Series condensing units are
mounted near a wall, the condenser air should
discharge away from the wall. This will provide
inherent coil protection and the best possible
sound and airflow performance.
Winter start The use of a winter start control
may extend the operation range (generally to 35
F or 40 F). Winter start bypasses the lowpressure switch for 3 minutes.
Crankcase heater Units with low ambient
control should be equipped with crankcase
heaters to prevent refrigerant migration during
compressor off cycle.
20
Refrigerant lines
General refrigerant line sizing:
1. All charges, line sizing, and capacities are
based on runs of 25 ft. For runs over 25 ft,
consult the appendix A.
NOTE: The minimum line length should be 10 ft.
MAXIMUM LINE LENGTHS
UNIT
MAXIMUM
EQUIVALENT
FT
MAXIMUM LIFT
FAN COIL
BELOW
CONDENSING
UNIT
MAXIMUM LIFT
FAN COIL
ABOVE
CONDENSING
UNIT
38HK
50
30*
30*
LIMITS
125
55
35
20 55
60 150
275
60
Controls
Unit operation
The indoor blower starts according to the
normal fan coil unit sequence of operation.
The control relay (in the outdoor unit) initiates
operation of a cooling cycle for the
compressor. As the set point at the fan coil is
satisfied, its individual signal to the 38HK unit
stops.
38 Series outdoor condensing unit The
outdoor unit is equipped with a control that
monitors the indoor fan coil cooling request.
Unit malfunction Each unit is equipped
with a high-pressure switch (HPS), a low
pressure switch (LPS),
Compressor over current protection is
achieved by an internal line break overload,
which automatically resets when the motor
temperature cools to a satisfactory level.
38HK/HQ
21
38HK/HQ
Appendix
Long-Line Guideline.
Reference:
Catalog No. 513-868
22
LONG-LINE GUIDELINE
REQUIRED FOR
LOW-AMBIENT APPLICATIONS
(BELOW 55F)
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(OVER 50 FT)
REQUIRED FOR
SEA COAST
APPLICATIONS
(WITHIN 2 MILES)
Yes
Yes
Yes
No
Yes
No
No
No
No
No
No
No
Yes
Yes
No
Yes
No
No
Wind Baffle
Coastal Filter
Support Feet
No
No
No
No
Yes
Recommended
No
See Long-Line
Application
Guideline
No
Yes
Yes**
No
No
No
No
ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay
38HK/HQ
*For tubing line sets between 50 and 175 ft, refer to Residential Split-System Long-Line Application Guideline.
Only when low-pressure switch is used.
Required for Low-Ambient Controller (full modulation feature) and MotorMaster control only.
** Required on Heat Pumps only.
23
38HK/HQ
24
EXAMPLE:
To calculate additional charge required for a 25ft
line set: 25 ft 15 ft
= 10 ft X 0.6 oz/ft = 6 oz of additional charge
38HK/HQ
48,000
60,000
LONG-LINE
VAPOR-LINE
DIAMETER (IN.)**
5/8
3/4
5/8
3/4
5/8
3/4
3/4
7/8
3/4
7/8
1-1/8
3/4
7/8
1-1/8
7/8
1-1/8
75
100
125
150
175
5
1
6
0
6
2
7
2
7
3
0
10
4
0
7
1
7
3
9
1
8
3
10
4
10
4
0
14
6
0
9
2
9
4
13
1
10
4
14
6
13
6
1
18
7
1
11
2
12
5
16
2
13
5
17
8
17
7
1
22
9
1
14
3
12
5
19
3
15
6
21
10
20
8
2
NR
11
2
16
3
14
7
22
4
17
7
NR
11
23
10
2
NR
13
2
19
4
*The estimated percentage of cooling capacity that must be subtracted from the Detailed Cooling Capacities data specified in outdoor
unit-presale literature for any given indoor/outdoor combination.
**Vapor-line diameter that may be selected for a long-line application. If smaller vapor lines are selected but not specified within the
table, large capacity losses will occur and defrost capabilities will be reduced. If larger vapor lines are selected but not specified within
the table, refrigerant oil return will be impaired due to velocity losses.
N/RNot recommended due to excessive loss of capacity.
25
38HK/HQ
90 STD
45 STD
26
A
1.6
1.8
2.0
2.6
C
0.8
0.9
1.0
1.3
PISTON CHANGE
0
-3
-5
-7
-9
-10
38HK/HQ
PISTON CHANGE
0
+4
PISTON CHANGE
0
+4
+6
+8
+10
OUTDOOR UNIT BELOW INDOOR
FT
0-50
PISTON CHANGE
0
35
38
40
42
46
49
51
52
55
57
59
61
63
CHATLEFF
32
33
35
36
37
38
39
40
41
42
43
45
47
49
51
52
53
55
57
59
61
62
63
ACCURATER
65
67
70
73
76
78
80
82
84
86
88
90
93
96
98
101
104
109
CHATLEFF
65
67
68
70
71
73
74
76
78
80
81
82
84
86
88
89
90
92
93
96
98
101
104
PART NO.
KAALS0101LLS
KHALS0101LLS
27
38HK/HQ
175' MAX.
GROUND LEVEL
175' MAX.
GROUND LEVEL
28
38HK/HQ
TRAP
50' MAX.
GROUND LEVEL
Fig. 4-Application with Air Conditioner or Heat Pump Installed with Indoor Unit above Outdoor Unit
29
38HK/HQ
150' MAX.
Fig. 5Application with Air Conditioner or Heat Pump Installed Above Indoor Unit
30
38HK/HQ
Notes
31
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations
2011
38HK-03 PD 60HZ