Sie sind auf Seite 1von 32

CALGARY 3 APRIL 2012

CONNECTIONS FOR STEEL STRUCTURES


John Mark P.Eng.

Steel Handbook
10th Edition 2010

Connection Reference CSA S16-09

COURSE AGENDA
1. 2. 3. 4. 5. 6. 7. 8. 9. Introduction Bolts and Welds Types of Construction Permitted Economics Types of Connections New Connection Guidelines in CSA S16-09 Connection Comments Summary Q&A

CONNECTIONS FOR STEEL FRAMED STRUCTURES Structural Analysis:

Connection Design & Detailing

CONNECTIONS FOR STEEL FRAMED STRUCTURES

As Built Connection

BOLTS & WELDS

STRUCTURAL BOLTS
A307 A325 A490 Heavy Hex

..and equivalents F 1852 F 2280

A325 A490 Heavy Hex

10

theres a new kid on the block! the SUPER HIGH STRENGTH BOLT
A325 at 830 MPa A490 at 1040 MPa X??? at 1400 MPa

11

threads in the shear plane or not ?

12

Twist - Off Assembly...

as delivered

13

Use of DTI Washers ASTM 959

14

Shop Welding Welding performed under controlled conditions


15

Field Welding Welding performed under varying conditions


16

Weld Metal
Weld electrodes are selected to match or overmatch the specified minimum tensile strength of the base metal (CSA Standard W59). The term Xu is the electrodes tensile strength E49XX electrodes, Xu = 490 MPa.

17

Basic Weld Types

18

Shear strength of welds


Weld resistances use a resistance factor = 0.67, lower than 0.90 that is used for the resistances involving the base metal to preclude the failure of the weld before that of the main material. Weld failures do not involve large deformations. Therefore a higher margin of safety against weld failures has been traditional practice in codes and standards.

19

Factored Resistance of Fillet Welds for Direct shear or Tension/Compression Induced Shear

Where = angle, in degrees, of axis of weld segment with respect to the line of action of the applied force, 00 for longitudinal weld and 900 for a transverse weld. Mw = strength reduction factor for multi-orientation fillet welds

Base metal check is not required for design of fillet welds.


20

Fillet Weld @ 90 Degrees to Force

Vr = 0.67x0.67x4.24x.490x1.5 x1.0 = 1.3995 kN/mm or 1.40 vs (1.21 kN/mm) 16%


21

CSA S16-09 permits three construction types 8.2.2 Rigidly connected and continuous construction

Construction Types

8.2.3 Simple construction

8.2.4 Semi-rigid (partially restrained) construction


22

Economics

23

Economics
Strength, serviceability and overall cost. Fabrication costs are influenced by the amount of: cutting, hole making, fitting, handling, assembly and joining of detail material to main material. (Therefore fabrication costs are directly influenced by the complexity of detail.) Erection costs are influenced by the time to erect, plumb and complete the connections.

24

Economics
Simplified economical cost breakdown of Structural Steel Price: Material: 33%

Fabrication: 33% Erection: 33%

25

Connection Behaviour
Connections permit forces to travel to adjoining members to relieve the effects of local stress concentrations at the member intersections or to stabilize certain compression elements. Complexities of connection behaviour cannot be readily analyzed by conventional means. Based on research, rational models and procedures have been developed for analyzing connections and simple rules have been established for proportioning connection components
26

Connection Design

Should not be approached as an exact science


The designer should carry out a rational analysis to determine a realistic distribution of forces within the connection. Failure modes for the connection must be established and are usually based on a simple concept of force paths The designer must ensure that each component of each force path has sufficient strength and stiffness to transmit the required forces
27

SEVERAL EXAMPLES OF TYPES OF CONNECTIONS

28

SIMPLE SHEAR CONNECTIONS

29

SIMPLE SHEAR CONNECTIONS

30

Shear Tab

31

Bracing Connections

32

Column Connections

33

Moment Connections

34

Truss Connections

35

36

HSS CONNECTIONS

37

CONNECTIONS FOR STEEL FRAMED STRUCTURES

New for CSA S16-09 re: connection design

Clause 27 (Seismic Design) is not covered in this course


38

New clause CSA S16-09, Clause 13.11

Block Shear Strength


Tr = u[UtAnFu+0.6Agv(Fy+Fu)/2]
Ut = efficiency factor per connection type An = net area in tension Agv = gross area in shear
= 0.75

39

Bolts in Bearing & Shear, Clause 13.12.1.2

40

fastener shear strength can only be achieved if sufficient BEARING STRENGTH is there
now we must look at the material of the connected member to provide local strength to develop shear this bearing strength saw major revisions in the 1970s when it was expressed in terms of the Fu of the connected plate

41

The bearing is now linked to tear out


There is no longer a poison bolt Br = n e t Fu Bearing has a higher resistance factor = 0.8 Long slotted holes have a reduced (80 %) bearing strength.. Br = 2.4 n d t Fu Tear out tends to be a small connection problem - make them larger; avoid minimum gage/pitch Many new mechanisms for tear out are now recognized ..but why do new equations for block shear keep appearing?
42

the questions of tear out strength


What does the ultimate state look like? Can tensile and shearing strengths occur simultaneously? If not we need to factor to include the effect.

43

Shear through the threads or not

44

Resistance of M/D fillet welds, Clause 13.13.2.2

45

Example (summary)
Per S16-09
Trans. weld

= .933 x 1.5 x 1.0 x 100


Long. welds

= 140 kN

= .933 x 1.0 x 0.85 x 600 = 476 kN Total = 616 kN Previous method A = 1.21 x 100 + .933 x 600 = 681 kN
(about 11 % higher)

Previous method B = 0.933 x 700


(about 6% higher)

= 653 kN

46

Welds & Bolts in Combination, Clause 13.14

Vr = the largest of:

47

48

Example

Determine Pr = ?

49

Example Solution

50

Bolts in Bending (Fills), Clause 21.8.1.2


In bolted splices the designer can now account for the bending of the bolts

Rv = 1.1 0.0158t
Rv is the bolt reduction factor, t is the thickness of the fillers Valid from t = 6.4 mm up to t = 19 mm

51

Column Splice Fillers

52

Fills with Bolts


Example;
Using 13 mm of loose fills, Rv = 1.1 0.0158 x 13 = 0.895 Therefore 89.5% of the applicable bolt shear is allowed And at 19mm of loose fills, Rv = 1.1 0.0158 x 19 = 0.80 or 80% of the applicable bolt shear value Research on thicker loose fill plates is continuing
53

Shear Resistance of Col. Webs,


Clause 13.4.2 & Clause 21.3

If Vr calculated from Clause 13.4.2

(= 0.8AwFs )

is exceeded, the column section should either be changed to one with a heavier web or appropriate web reinforcement must be designed.

54

CONNECTION COMMENTS

55

CONNECTION COMMENTS

56

CONNECTION COMMENTS

57

Typical Stiffener Details

58

CONNECTION COMMENTS

59

Connection Forces

60

CONNECTION COMMENTS

61

SUMMARY
Dont always stick to least weight design Visualize how pieces can be connected Lines always connect Reduce stiffeners where feasible before tendering Dont have small lightweights resist large reactions Talk to your friendly fabricator