Sie sind auf Seite 1von 16

NetNumen M31V12.11.

40Acceptance Test Record For Viettel


Netnumen M31 Test Record

NetNumen M31V12.11.40Acceptance Test Record For Viettel

Netnumen M31 Test Record For Viettel


Version V1.0 Date 2011-12-20 Author Approved By Remarks Not open to the Third Party

2013 ZTE Corporation. All rights reserved. ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used without the prior written permission of ZTE. Due to update and improvement of ZTE products and technologies, information in this document is subjected to change without notice.

ZTE Confidential Proprietary

2013 ZTE CORPORATION. All rights reserved.

NetNumen M31V12.11.40Acceptance Test Record For Viettel

TABLE OF CONTENTS
1. Topology Management...................................................................................................1 2. Performance Management.............................................................................................2 3. Fault Management..........................................................................................................4 4. Security Management.....................................................................................................6 5. Configuration Management............................................................................................7 6. Software Management....................................................................................................8 7. Log Management..........................................................................................................10 8. System Management....................................................................................................11 9. Acceptance conclusion................................................................................................12 10. Test Conclusion..........................................................................................................13

II

2013ZTE CORPORATION. All rights reserved.

ZTE Confidential Proprietary

NetNumen M31V12.11.40Acceptance Test Record For Viettel

1.

Topology Management
Item No. Test item Result Conclusion Remark NE Agent Management 2.1.1.A 2.1.2.A 2.1.3.A 2.1.4.A 2.1.5.A 2.1.6.A 2.1.7.A Creating an NE Agent Starting the NE Agent Modifying the NE Agent Attribute Deleting the NE Agent Starting the NE Management Stopping the NE Management Force to Upload NE Version Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

Navigation Operation 2.2.1.A Navigating to FM Pass Fail

Topology Tools 2.3.1.A Maintain Status Search and Set Pass Fail

NetNumen M31V12.11.40Acceptance Test Record For Viettel

2.

Performance Management
Item No. Test item Result Conclusion Remark Measurement Task Management 3.1.1.A 3.1.2.A 3.1.3.A Creating Measurement Task Modifying Measurement Task Deleting Measurement Task Pass Fail Pass Fail Pass Fail

Threshold Task Management 3.2.1.A 3.2.2.A 3.2.3.A Creating a Threshold Task Modifying the Threshold Task Deleting the Threshold Task Pass Fail Pass Fail Pass Fail

Counter and Index Management 3.3.1.A 3.3.2.A 3.3.3.A Creating a Customized Index Modifying the Index Deleting the Index Pass Fail Pass Fail Pass Fail

Common Template Management 3.4.1.A 3.4.2.A 3.4.3.A Creating a Common Template Modifying the Common Template Deleting the Common Template Pass Fail Pass Fail Pass Fail

Template Task 3.5.1.A 3.5.2.A Creating Common Template Task Modifying the Template Task Pass Fail Pass Fail

2013ZTE CORPORATION. All rights reserved.

ZTE Confidential Proprietary

NetNumen M31V12.11.40Acceptance Test Record For Viettel

Item No. 3.5.3.A

Test item Deleting the Template Task

Result

Conclusion Pass Fail

Remark

Performance Data Query 3.6.1.A 3.6.2.A 3.6.3.A 3.6.4.A 3.6.5.A Performance Data Query Querying by Template Task Querying PM Data by Task Querying by Template Realtime Data Query Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

NetNumen M31V12.11.40Acceptance Test Record For Viettel

3.

Fault Management
Item no. Current Alarm 4.1.1.A 4.1.2.A 4.1.3.A 4.1.4.A 4.1.5.A Realtime Alarm Monitoring Details of Alarm Acknowledging/Una cknowledging an Alarm Clearing an Current Alarm Locating an Alarm to the Rack Map Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Test item Result Conclusion Remark

History Alarm 4.2.1.A Clearing Current Alarm Pass Fail

Notification Monitoring 4.3.1.A Realtime Notification Monitoring Pass Fail

Alarm Synchronization 4.4.A Alarm Query 4.5.1.A 4.5.2.A Querying Current Alarms Saving the Current Alarm Query Conditions Modifying a Current Alarm Query Condition Deleting a Current Alarm Query Condition Querying History Alarms Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Alarm Synchronization Pass Fail

4.5.3.A

4.5.4.A 4.5.5.A

2013ZTE CORPORATION. All rights reserved.

ZTE Confidential Proprietary

NetNumen M31V12.11.40Acceptance Test Record For Viettel

Item no. 4.5.6.A

Test item Saving the History Alarm Query Conditions Modifying a History Alarm Query Condition Deleting a History Alarm Query Condition Querying Notifications Saving the Notification Query Conditions Modifying a Notification Query Condition Deleting a Notification Query Condition

Result

Conclusion Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

Remark

4.5.7.A

4.5.8.A 4.5.9.A 4.5.10.A

4.5.11.A

4.5.12.A

Setting Alarm Rules 4.6.1.A 4.6.2.A 4.6.3.A 4.6.4.A Creating an Alarm Rule Disabling an Alarm Rule Deleting an Alarm Rule Severity Regarding Setting Pass Fail Pass Fail Pass Fail Pass Fail

NetNumen M31V12.11.40Acceptance Test Record For Viettel

4.

Security Management
Item No. User Management 5.1.1.A 5.1.2.A 5.1.3.A 5.1.4.A Creating a User Modifying a User Disabling a User Deleting a User Pass Fail Pass Fail Pass Fail Pass Fail Test item Result Conclusion Remark

Role Management 5.2.1.A 5.2.2.A 5.2.3.A 5.2.4.A 5.2.5.A 5.2.6.A Creating a Role Modifying a Role Creating a Role Set Modifying a Role Set Deleting a Role Set Deleting a Role Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail

Department Management 5.3.1.A 5.3.2.A 5.3.3.A Creating a SubDepartment Modifying a SubDepartment Deleting a SubDepartment Pass Fail Pass Fail Pass Fail

2013ZTE CORPORATION. All rights reserved.

ZTE Confidential Proprietary

NetNumen M31V12.11.40Acceptance Test Record For Viettel

5.

Configuration Management
Item No. Data Configuration 6.1.1.A Opening the Configuration Management Interface Creating a NE Applying/Releasing Mutex right Creating an RNC Config set Viewing NE information Importing RNC data Modifying NE information Synchronizing all/modified tables Backing up data Deleting an NE Recovering Data Offline reverse of NodeB data Synchronizing all/modified tables of NodeB Exporting NodeB data Switching the config set Comparing data Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Test item Result Conclusion Remark

6.1.2.A 6.1.3.A 6.1.4.A 6.1.5.A 6.1.6.A 6.1.7.A 6.1.8.A 6.1.9.A 6.1.10.A 6.1.11.A 6.1.12.A 6.1.13.A 6.1.14.A 6.1.15.A 6.1.16.A

NetNumen M31V12.11.40Acceptance Test Record For Viettel

Item No.

Test item

Result

Conclusion

Remark

Configuration Management 6.2.1.A 6.2.2.A 6.2.3.A RNC configuration management Nodeb Config Report SDR Data Batch Configure Management Pass Fail Pass Fail Pass Fail

MML Command 6.3.1.A 6.3.2.A


QueryAllMutex SHOW ALLUSER

Pass Fail Pass Fail

6.

Software Management
Item No. Test item Result Conclusion Remark Entering Software Management 7.1.A Entering software management Pass Fail

RNC Software Version Management 7.2.1.A 7.2.2.A 7.2.3.A 7.2.4.A Creating version file Query Version of RNC Downloading version to ROMP Package Activation Pass Fail Pass Fail Pass Fail Pass Fail

Base Station Version Management 7.3.1.A 7.3.2.A 7.3.3.A Creating version package Downloading package Package Activation Pass Fail Pass Fail Pass Fail

2013ZTE CORPORATION. All rights reserved.

ZTE Confidential Proprietary

NetNumen M31V12.11.40Acceptance Test Record For Viettel

Item No. 7.3.4.A

Test item Querying NodeB Version

Result

Conclusion Pass Fail

Remark

NetNumen M31V12.11.40Acceptance Test Record For Viettel

7.

Log Management
Item No. Viewing the Logs 8.1.A Viewing the Logs Pass Fail Test item Result Conclusion Remark

Querying the Operation Log 8.2.A Querying the Operation Log Pass Fail

Querying the System Log 8.3.A Querying the System Log Pass Fail

Querying the Security Log 8.4.A Querying the Security Log Pass Fail

Exporting the Logs 8.5.A Exporting the Logs Pass Fail

10

2013ZTE CORPORATION. All rights reserved.

ZTE Confidential Proprietary

NetNumen M31V12.11.40Acceptance Test Record For Viettel

8.

System Management
Item No. Application Server 9.1.1.A 9.1.2.A 9.1.3.A Showing Device Information Server Performance Configuring Performance Monitor Pass Fail Pass Fail Pass Fail Test item Result Conclusion Remark

Maintaining Database Server 9.2.1.A 9.2.2.A Configuring Database Monitor Viewing Database Resource Pass Fail Pass Fail

NetNumen M31V12.11.40Acceptance Test Record For Viettel

9.

Acceptance conclusion

Users representativ e

Signature:

Date:

ZTE representativ e

Signature:

Date:

Supervisors representativ e

Signature:

Date:

Construction units representativ e

Signature:

Date:

12

2013ZTE CORPORATION. All rights reserved.

ZTE Confidential Proprietary

NetNumen M31V12.11.40Acceptance Test Record For Viettel

10.

Test Conclusion

Test conclusion:

On behalf of Viettel

On behalf of ZTE

Signature:

Signature:

Person in Charge of Test:

Date:

Das könnte Ihnen auch gefallen