Sie sind auf Seite 1von 2

Dimensional drawing

24.6

54

40 50

Adjustments possible WL23-2P2432S02

1 2 3 4 5 6

Optical axis, sender Optical axis, receiver Mounting hole 5.2 mm LED indicator green; power on LED indicator yellow; status of received light beam Sensibility adjustment: single teach button

TEACH 2 ... 6 s
6

TI

Scanning range

0.1 ... 15 m
Photoelectric reflex switch

Connection type WL23-2P2432S02

Plug & play, ready to operate in less time Intensive and visible light spot, therefore faster commissioning Teach-in: easy, fast and reproducible set-up

M12, 4-pin
brn blk wht blu

1 4 2 3

L+ Q Q M

A T A

Photoelectric reflex switch Pin-Point Te c h n o l o g y

45

6 5.2 3

12.2

H E E T

WL23-2 P2432S02

80.6

70

49.4

10

23

WL23-2P2432S02, Photoelectric reflex switch, red light Pin-Point Technology DC


Technical data WL23-2 P2432 S02

Scanning range, typ. max. Operating range, recommended Relating to Sensitivity setting Light source, light type Light spot diameter Angle of dispersion Polarisation filter Supply voltage VS Residual ripple Current consumption Switching outputs Signal voltage PNP HIGH/LOW Output current Iamax Response time Switching frequency Connection type VDE protection class Circuit protection8) Enclosure rating Ambient temperature Weight Housing material
1)

0.1 ... 15 m 0.1 ... 11 m Reflector PL80A Teach-in: single teach button Pin-Point LED, red light1) Approx. 160 mm at 16 m distance Approx. 0.6 10 ... 30 V DC2) 5 VPP3) 35 mA4) PNP, antivalent > VS 2.5 V/approx. 0 V 100 mA 1 ms5) 500 Hz6) Connector, M12, 4-pin

V 7)

A, B, C8) IP 67 Operation 30 C ... +60 C Storage 40 C ... +70 C Approx. 100 g ABS, PMMA
2)

Average service life 100,000 h at Ta = +25 C

3)

Limit values, operation in short-circuit protected network max. 8 A May not exceed or fall short of VS tolerances

4) 5) 6) 7)

Without load Signal transit time with resistive load With light/dark ratio 1:1 Reference voltage 50 V DC

8)

A = VS connections reverse-polarity A = protected B = All outputs short-circuit protected C = Interference pulse suppression

Teach-in function Align the light beam of the reflex switch on the reflector, press Teach-in button (2 ... 6 s); (approx. double reserve over switching threshold); adjustment is completed. Yellow LED lights up and confirms the Teach-in procedure.

Order information Type Order no. 1043566 WL23-2P2432S02

2009-03-24 GO/GO Printed in Germany (2009-04) Subject to change without notice 01 lin en32

Great Britain Phone +44 (0)1727 83 11 21 E-Mail info@sick.co.uk USA Phone +1(952) 941-6780 tollfree +1-800-325-7425 E-Mail info@sickusa.com Australia Phone +61 3 9497 4100 tollfree +1800 33 48 02 E-Mail sales@sick.com.au

More representatives and agencies in all major industrial nations at www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com