SMC guide to ATEX compliant products

SMC - provide products c


Outline of ATEX directive
Since 1st July 2003, equipment used in potentially explosive atmospheres within the EU is required to comply with the ATEX directive.
Directive 94/9/EC Equipment and Protective Systems intended for use in potentially Explosive Atmospheres
ATEX,
Directive 94/9/EC, known as ATEX directive, is one of the directives based on the New Approach towards technical harmonization and standardisation. The New Approach is a new regulatory technique and strategy laid down by the European Council Resolution of 1985, in order to allow free movement of goods within the EU market and to prevent barriers to trade. Products in compliance with all provisions of applicable directives (such as Directive 94/9/EC for ATEX) must bear the CE marking. This is an indication that the products comply with the requirements of applicable directives and have been subjected to the conformity assessment procedure provided for in these directives.

ATEX directive

New Approach directives and CE marking

ATEX

Potentially explosive atmospheres are atmospheres likely to become explosive due to local and operational conditions. The ATEX directive regards explosive atmospheres which are defined as mixtures with air, under atmospheric conditions, of flammable substances in the form of gases, vapours, mists or dusts in which, after ignition has occurred, combustion spreads to the entire unburned mixture. (Quotation from Directive 94/9/EC) The following applications are explicitly excluded by the ATEX directive and must comply with other specific standards: medical devices, equipment or safety devices to be used with explosive or chemically unstable substances, equipment for domestic and non-commercial environments with explosive atmosphere generated by leakage of fuel gas, personal protective equipment, offshore vessels, mobile units and means of transport. Certified equipment is designed to prevent the generation of ignition sources as defined by the standard EN1127-1: hot surfaces flames and hot gases Zone 2 Zone 1 mechanically generated sparks Category 3 Category 2 electrical sparks stray electric currents, cathodic corrosion protection static electricity Zone 0 lightning electromagnetic fields Category 1 electromagnetic radiations ionising radiations ultrasonics adiabatic compression shock waves, gas flows chemical reactions

definitions

Classification

Potentially explosive environments are classified into zones in accordance with Directive 1999/92/EC. These are: 0, 1, 2 for gas explosive atmospheres 20, 21, 22 for dust explosive atmospheres

The ATEX directive defines categories of equipment and protective systems, which can be used in the corresponding zones as per the following table. Zone Presence of the explosive Equipment atmosphere category Gas Dust Continuously or for long periods 1 0 20 >1000 hours/year Occasionally 2 1 21 10~1000 hours/year Rarely or for short periods 3 2 22 <10 hours/year

ts compliant to ATEX Directive


New elements at a glance
Previous legislation covered the most obvious sources of ignition generated by electrical devices. The ATEX directive and the corresponding harmonised standards have extended the applicability of legislation to all the equipment that is intended for generation, transfer, storage, measurement, control and conversion of energy. Pneumatic equipment used in potentially explosive atmospheres must, therefore, comply with the new legislation. Products, which do not contain any potential ignition sources, are out of the scope of the directive.

ATEX

label example and explanation


"Do not un-plug when energized"
Group Category

SMC CORPORATION 1-16-4,Shimbashi Minato-ku, Tokyo, Japan

II 3 G / D EEx nA II T6 X
VQCxxx HO Tamb =-10C to +50C IP65 T 80C

II 1 G D G 2 D G 3 D

ATEX compliance

Atmosphere* *G=Gas D=Dust

Category General requlrements all all

Standards Standards for for Electrical Non-electrical product product EN 50014 EN13463-1

Part-number Year Operating temperature IP (only for Dust) T temperature(only for Dust)

Dust protection Types of Protection Constructional safety "c" Max. Surface temperature Types of Protection "n" Increased Safety "e" Encapsulation "m" Flameproof Enclosure "d" Oil lmmersion "o" Pressurized "p" Powder Filling "q" Intrinsically Safety "ia" Intrinsically Safety "ib"

EN 50281-1-1 EN13463-1 EN13463-5 EN50021 EN50019 EN50028 EN50018 EN50015 EN50016 EN50017 EN50020 EN50020

2 3 2 2 2 2 2 2 1 2

T1 T2 T3 T4 T5 T6

450C 300C 200C 135C 100C 85C

EN13463-3 EN13463-7

X = means that special conditions for use are in the operating manual. E.g. ; Not impact proof.

INDEX
Actuator 55-C76 Air Cylinder 55-C85 Air Cylinder 55-C95 Air Cylinder 55-CP95 Air Cylinder 55-CG1 Air Cylinder 55-CS1 Air Cylinder 55-(E)CQ2 Compact Cylinder 55-CXS Dual Rod Cylinder 55-MY1B Mechanically Rodless Cylinder 55-MY1H Mechanically Rodless Cylinder P. 04 P. 06 P. 08 P. 10 P. 12 P. 14 P. 16 P. 18 P. 20 P. 22 Rotary Actuator 55-CRB1 Rotary Actuator 55-CRB2 Rotary Actuator 55-CRBU2 Rotary Actuator 55-C(D)RQ2 Rotary Actuator 56-C(D)RB1 Rotary Actuator 56-C(D)RB2 Rotary Actuator 56-C(D)RBU2 Rotary Actuator Auto Switches Instruments IP5000 Pneumatic Positioner IP6000-X14 Electro Pneumatic Positiner IP8000-X14 Electro Pneumatic Positiner 52-IP8101 Smart Positiner P. 50 P. 51 P. 54 P. 58 P. 24 P. 26 P. 28 P. 30 P. 32 P. 34 P. 36 P. 38 Others 56-PA3000/5000 Process Pump 56-VBA Booster Regulator Directional Valves 52-SY 5 Port Solenoid Valves 56-SV 5 Port Solenoid Valves 56-VQC 5 Port Solenoid Valves 56-VX21/22/23 2 Port Valves 56-EX250 Serial Transmission 56-EX500 Serial Transmission Safety Precautions Safety Instruictions P.125 P. 62 P. 82 P. 94 P.109 P.120 P. 121 P. 60 P. 61

55-MY1M Mechanically Rodless Cylinder P. 21

ATEX Compliant Air cylinder/ Double acting

Series
32, 40

55-C76
How to order

55 - CD76 E 32
ATEX category 2 Built-in magnet
D None Built-in magnet

50 C

Cushion
C Rubber cushion Air cushion (only "E" execution)

Mounting
E Double end type F Front nose type Y Front nose in line type
Except for air cushion type.

Bore size
32 40 32mm 40mm

Standard Stroke
Bore size 32mm 40mm Standard stroke (mm) 10, 25, 40, 50, 80, 100 125, 160, 200, 250, 300 Max. stroke (mm) 1000

Parts No. of Mounting Bracket


Mounting bracket Bore size (mm)

Flange, Foot (1pc.) Flange, Foot Mounting bracket


(2 pcs. with mounting nut 1 pc.)

32 C76F32A C76F32B C76T32 C76C32 KJ10DA GKM10-20A JA25-10-150

40 C76F40A C76F40B C76T40 C76C40 KJ12DA GKM12-24A JA40-12-175

Accessories

Trunnion Clevis Single knuckle joint Double knuckle joint Floating joint

For 55-CD76 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A73(H), A80(H), F7P(V), C73, C80, and H7A2, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Type Model No. Rail mounting D-A73 -588 D-A80 -588 Reed auto switch D-A73H -588 D-A80H -588 Solid state auto switch D-F7PV -588 D-F7P -588 D-C73 -588 D-C80 -588 Band mounting Indicator Electrical entry Wiring (Output) 24V 2-wiring 24V Load voltage DC 12V 48V or less 48V or less IC circuit IC circuit IC circuit solid state auto switch is available after receiving an order. Relay PLC 12V AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Yes Grommet (Perpendicular entry) No Grommet (In-line entry) Yes No

24V or less 48V 24V or less 48V 24V 5V, 12V

Grommet (Perpendicular entry) Yes 3-wiring Grommet (PNP) D-H7A2 -588 (In-line entry)

Lead wire length

0.5m --- Nil (e.g.) D-A73-588 3 m --- L (e.g.) D-A73L-588 5 m --- Z (e.g.) D-A73Z-588

Note 1)

Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, which is the same category as the auto switch.

When ordering a band mounting type auto switch, also order a mounting bracket from the following list at the same time. Auto switch mounting bracket/ Part no. (Band mounting type)

Auto switch Model D-C73 -588 D-C80 -588 D-H7A2 -588

Tube I.D. (mm) 32 40 BM2-032 BM2-040

ATEX Compliant Air Cylinder Standard: Double Acting

Series

55-C76

Specifications
Bore size ATEX category 1) Action Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Operating piston speed Allowable stroke tolerance Cushion Thread tolerance Port size G1/8 32 40

II 2GDc

90C (T5) Ta 10 to 40C 110C (T4) Ta 40 to 60C Air

Double acting 1.5MPa 1.0MPa 0.05MPa 10 to 60C (No freezing) Not required (Non-lube) 50 to 1500 mm/s 0/+1.4 Rubber cushion, Air cushion JIS class 2 G1/4

Symbol
Standard: double action Rubber Cushion Single rod

Mounting

Double end, Front nose, Front nose in line

Note 1) This cylinder can be used in zones 1 and 21 and in zones 2 and 22. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zones 2 and 22 and not in zones 1 and 21.

Air Cushion Single rod

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

ATEX Compliant ISO Cylinder/Standard: Double Acting

Series
Double acting Single rod
ATEX category 2 Magnet
None D Built-in magnet

8, 10, 12, 16, 20, 25

55-C85
How to Order
100 C
Cushion
C

55-C D 85 N 16

Rubber bumper (Standard) Air cushion (only "N" execution, bores 10 to 25mm)

Head cover style


Mounting Symbol Basic integrated clevis N Double end type E Front nose type F Y Front nose in line type
Except for air cushion type

Bore size (mm) Standard stroke (mm) 8 10, 25, 40, 50, 80, 100 10 12 10, 25, 40, 50, 80, 100, 16 125, 160, 200 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 25
Not available with air cushion. Other strokes available on request.

Bore size-Stroke

Max. stroke 400

1000

Mounting Bracket Part No.


Bore (mm) Bracket

10

12

16

20

25

Foot (1 pc.) Foot (2 pcs. with mounting nut 1 pc.) Flange Trunnion Clevis Single knuckle joint Double knuckle joint Floating joint

C85L10A C85L10B C85F10 C85T10 C85C10 KJ4D GKM4-8 JA10-4-070

C85L16A C85L16B C85F16 C85T16 C85C16 KJ6D GKM6-10 JA15-6-100

C85L25A C85L25B C85F25 C85T25 C85C25 KJ8D KJ10D GKM8-16 GKM10-20 JA20 JA30 -8-125 -10-125

Note) Please order mounting brackets separately. For 55-CD85 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A73(H), A80(H), F7P(V), C73, C80, and H7A2, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Type Model No. Rail mounting D-A73 -588 D-A80 -588 Reed auto switch D-A73H -588 D-A80H -588 Solid state auto switch D-F7PV -588 D-F7P -588 D-C73 -588 D-C80 -588 Band mounting Indicator Electrical entry Wiring (Output) 24V 2-wiring 24V Load voltage DC 12V 48V or less 48V or less IC circuit IC circuit IC circuit solid state auto switch is available after receiving an order. Relay PLC 12V AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Yes Grommet (Perpendicular entry) No Grommet (In-line entry) Yes No

24V or less 48V 24V or less 48V 24V 5V, 12V

Grommet (Perpendicular entry) Yes 3-wiring Grommet (PNP) D-H7A2 -588 (In-line entry)

Lead wire length

0.5m --- Nil (e.g.) D-A73-588 3 m --- L (e.g.) D-A73L-588 5 m --- Z (e.g.) D-A73Z-588

Note 1)

Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, which is the same category as the auto switch.

When ordering a band mounting type auto switch, also order a mounting bracket from the following list at the same time. Auto switch mounting bracket/ Part no. (Band mounting type)

Auto switch Model D-C73 -588 D-C80 -588 D-H7A2 -588

10

12

Tube I.D. (mm) 16 20

25

BJ2-008 BJ2-010 BJ2-012 BJ2-016 BM2-020 BM2-025

ATEX Compliant ISO Cylinder/Standard: Double Acting

Series

55-C85
20 25

Specifications
Bore size (mm) Rubber Bumper/Single Rod ATEX category 1) Piston rod dia. (mm) Piston rod thread Ports Action Fluid Air Cushion/Single Rod Proof pressure Max operating pressure Min operating pressure Ambient and fluid temperature Cushion Lubrication Piston speed Allowable kinetic energy Rubber Bumper Air Cushion Rubber bumper Air cushion 0.02J 0.03J 0.17J 0/+1 0.1MPa 0.08MPa 10 to 60C Rubber bumper, Air cushion (Except for 8) Not required. If necessary turbine oil no.1 ISOVG32 is recommended 50 to 1000mm/s 0.04J 0.19J 0.09J 0.4J 0.27J 0.64J 0.4J 0.93J 4 M4 X 0.7 M5 4 M4 X 0.7 M5 8 10 12 16

II 2GDc
6 M6 X 1 M5

90C (T5) Ta 10 to 40C 110C (T4) Ta 40 to 60C 6 M6 X 1 M5 8 G1/8 10 G1/8 M8 X 1.25 M10 X 1.25

Double acting Air 1.5MPa 1.0MPa 0.05MPa

Symbol
Double Acting/Single Rod

Stroke tolerance

0/+1.4

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Note 1) This cylinder can be used in zones 1 and 21 and in zones 2 and 22. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zones 2 and 22 and not in zones 1 and 21.

ATEX compliant ISO Cylinder: Double Acting

Series
ATEX category 2 Piston rod type
S K Standard Non-rotating rod (32~100 only)

32, 40, 50, 63, 80, 100, 125, 160, 200, 250 How to Order 55-C95SD B 32 100 W XC6
Special
XC6 Standard Stainless steel rod and nut

55-C95

Built-in magnet
D None Built-in magnet 32 40 50 63 80 100 125 160 200 250

Bore size Mounting


B L F G C D T Basic/Without bracket Axial foot Front flange Rear flange Single rear clevis Double rear clevis Centre trunnion 32mm 40mm 50mm 63mm 80mm 100mm 125mm 160mm 200mm 250mm

Rod Specifications
Hard chromed rod as standard W Note) Double rod
Note) Double rod is not available for bore size diameter

125, 160, 200, 250 mm.

Stroke (mm)
Refer to standard stroke table

Model Selection
Execution Model

Piston Rod Adjustable Options Stroke End Cushioning Standard Hard Chrome W 32 40 50 63 80 100 125 160 200 250

Bore size

55-C95 SB 55-C95 SDB 55-C95 ST With Mounting Centre Trunnion 55-C95 SDT 55-C95 KB Non-rotating 55-C95 KDB piston rod Standard Type

W = Double Rod Options Standard


Note 3 Note 3

Note1) 55-C95 can be used in zones 1 and 21 and in zones 2 and 22. Note2) If the 55-C95 cylinder is used with SMC category 3 type auto switch, then the 55-C95 cylinder can only be used in zones 2 and 22 and not zones 1 and 21. Note3) Piston rod material is stainless steel.

For 55-C95 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A54, A67, and F5P, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Indicator Type Model No. D-A54 -588 D-A67 -588 D-F5P -588 Grommet Electrical entry Wiring (Output) 2-wiring 3-wiring (PNP) Load voltage DC 24V 12V IC circuit IC circuit solid state auto switch is available after receiving an order. Relay PLC AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Reed auto switch Solid state auto switch

Yes No Yes

24V or less 24V 5V,12V Note 1)

Grommet

Lead wire length

When ordering a tie rod mounting type auto switch, also order a mounting bracket from the following list at the same time. Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, Auto switch mounting bracket/ Part no. (Tie rod mounting) which is the same category as the auto switch. Tube I.D. (mm) Auto switch

0.5m --- Nil (e.g.) D-A54-588 3 m --- L (e.g.) D-A54L-588 5 m --- Z (e.g.) D-A54Z-588

Model D-A54 -588 D-A67 -588 D-F5P -588

32,40 BT-03

50,63 BT-05

80,100 BT-06

125 BT-08

160 BT-16

200 BT-16

250 BT-20

Series
Specifications
Bore size ATEX category Action Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Operating piston speed 32 40 50 63 80

55-C95

100 125 160 200 250 95C (T5) Ta 10 to 40C 115C (T4) Ta 40 to 60C Air

II 2GDc

Double acting 1.5MPa 1.0MPa 0.05MPa 10 to 60C (No freezing) Not required (Non-lube) 50 to 1000 mm/s to 250:
+1.0, 0

ISO Symbol Double acting

50 to 700 mm/s
+1.4 ,1001 0

50 to 500 mm/s

Allowable stroke tolerance Cushion Thread tolerance Port size Mounting G1/8

251 to 1000:

to 1500: +1.8 0

Both ends (Air cushion) JIS class 2 G1/4 G1/4 G3/8 G3/8 G1/2 G1/2 G3/4 G3/4 Basic, axial foot, front flange, rear flange, G1

single rear clevis, double rear clevis, centre trunnion

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Standard Stroke
Bore size (mm) 32 40 50 63 80 100 125 160 200 250 Standard stroke (mm) 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Each stroke will be made to order Each stroke will be made to order Each stroke will be made to order (*) Max. stroke 700 800 1200 1200 1400 1500 1600 1600 2000 2400

Each stroke will be made to order (*) Please consult SMC for longer stroke.

Mounting Bracket, Mounting Accessories


Description

Bore size
(1)

32

40

50

63

80 L5080 F5080 C5080 D5080 DS5080 ES5080 E5080 C95-S06

100 L5100 F5100 C5100 D5100 DS5100 ES5100 E5100 C95-S10

125 L5125 F5125 C5125 D5125

160 L5160 F5160 C5160 D5160

200 L5200 F5200 C5200 D5200

250 L5250 F5250 C5250 D5250

L5040 L5050 Foot L5032 L5063 F5040 F5050 Flange F5063 F5032 C5040 C5050 Single rear clevis C5032 C5063 D5040 D5050 Double rear clevis D5032 D5063 Double rear clevis DS DS5032 DS5040 DS5050 DS5063 (for ES accessory) Angled rear clevis ES ES5032 ES5040 ES5050 ES5063 with ball joint E5040 E5050 Angled rear clevis E E5032 E5063 Trunnion pivot C95-S C95-S03 C95-S04 C95-S04 C95-S06 bracket GKM Rod clevis GKM10-20 GKM12-24 GKM16-32 GKM16-32 Piston rod ball joint KJ10D KJ12D KJ16D KJ KJ16D Floating joint JA JA30-10-125 JA40-12-125 JA50-16-150 JA50-16-150 L F, G C D
Note 1) Two foot brackets required for one cylinder. Note 2) Accessories for each mounting bracket are as follows. Foot, Flange, Single clevis: Mounting bolts Double rear clevis: (D,DS): Clevis pin Note 3) C95-S: Set of 2 pcs. Note 4) GKM according to ISO 8140 Note 5) KJ according to ISO 8139 Note 6) Piston rod nut is standard Note 7) Please consult SMC

Note 7)

GKM20-40 GKM20-40 KJ20D KJ20D JAH50-20-150 JAH50-20-150

ATEX Compliant ISO Cylinder/Standard: Double Acting

Series
ATEX category 2 Built-in magnet
D None Built in magnet

32, 40, 50, 63, 80, 100

55-CP95
How to Order 100 W
Rod Specifications
W

55-CP95SD B 32

Hard chromed rod as standard Double rod

Mounting
B L F G C D Basic/Without bracket Axial foot Front flange Rear flange Single rear clevis Double rear clevis

Stroke (mm) Bore size


32 40 50 63 80 100 32mm 40mm 50mm 63mm 80mm 100mm
Refer to standard stroke table following page

Model Selection
Execution Model Piston Rod Adjustable Options Stroke End Cushioning Standard Hard Chrome W

Standard Type W=Double Rod

55-CP95 SB 55-CP95 SDB


Options Standard

For 55-CP95 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-Z73, Z80, Y7P, and Y7PV, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Indicator Type Reed auto switch Solid state auto switch Model No. D-Z73 -588 D-Z80 -588 D-Y7P -588 D-Y7PV -588 Electrical entry Grommet (in-line) Grommet (in-line) Grommet (Perpendicular) Wiring (Output) 2-wiring Load voltage DC 24V 12V 48V or less IC circuit Relay PLC IC circuit AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Yes No Yes

24V or less 48V

3-wiring (PNP)

24V

5V,12V

Lead wire length

When ordering a direct mounting type auto switch, also order a mounting bracket from the following list at the same time. Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, Auto switch mounting bracket/ Part no. (Direct mounting type) which is the same category as the auto switch. Tube I.D. (mm) Auto switch

0.5m --- Nil (e.g.) D-Z73-588 3 m --- L (e.g.) D-Z73L-588 5 m --- Z (e.g.) D-Z73Z-588

Note 1)

solid state auto switch is available after receiving an order.

Model D-Z73 -588 D-Z80 -588 D-Y7P -588 D-Y7PV -588

32,40,50,63,80,100 BMP1-032

10

Series

55-CP95

Specifications
Bore size ATEX category 1) Action Fluid Proof pressure Max. operating pressure Min. operating pressure Lubrication Ambient and fluid temperature Operating piston speed Allowable stroke tolerance 32 40 50 63 80 100

II 2GDc

95C (T5) Ta 10 to 40C 115C (T4) Ta 40 to 60C

Double acting Air (Non-lube) 1.5MPa 1.0MPa 0.05MPa Not required (Non-lube) 10 to 60C 50 to 1000mm/s to 250:+1.0 , 251 to 1000:+1.4 0 0 Both ends (Air cushion) JIS class 2 G1/8 G1/4 G1/4 G3/8 G3/8 G1/2 Basic, axial foot, front flange, rear flange, single rear clevis, double rear clevis

ISO Symbol Double acting

Cushion Thread tolerance Port size Mounting

Note 1) This cylinder can be used in zones 1 and 21 and in zones 2 and 22. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zones 2 and 22 and not in zones 1 and 21.

Standard Stroke
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
Bore size (mm) 32 40 50 63 80 100 Standard stroke (mm) 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Max. stroke 700 800 1200 1200 1400 1500

Intermediate strokes are available.

Mounting Bracket, Mounting Accessories


Description L F, G C D DS ES E GKM KJ JA Bore size
(1)

32

40 L5040 F5040 C5040 D5040 DS5040 ES5040

50 L5050 F5050 C5050 D5050 DS5050 ES5050

63 L5063 F5063 C5063 D5063 DS5063 ES5063

80 L5080 F5080 C5080 D5080 DS5080 ES5080

100 L5100 F5100 C5100 D5100 DS5100 ES5100

L5032 Foot F5032 Flange C5032 Single rear clevis D5032 Double rear clevis Double rear clevis DS5032 (for ES accessory) Angled rear clevis ES5032 with ball joint E5032 Angled rear clevis Rod clevis GKM10-20 Piston rod ball joint KJ10D Floating joint JA30-10-125

E5100 E5080 E5040 E5050 E5063 GKM20-40 GKM20-40 GKM12-24 GKM16-32 GKM16-32 KJ20D KJ20D KJ12D KJ16D KJ16D JA40-12-125 JA50-16-150 JA50-16-150 JAH50-20-150 JAH50-20-150

Note 1) Two foot brackets required for one cylinder. Note 2) Accessories for each mounting bracket are as follows. Foot, Flange, Single clevis: Mounting bolts Double rear clevis: (D,DS): Clevis pin Note 3) GKM according to ISO 8140 Note 4) KJ according to ISO 8139 Note 5) Piston rod nut is standard

11

ATEX Compliant Air cylinder/ Double acting

Series
Standard With auto switch

20, 25, 32, 40, 50, 63, 80, 100

55-CG1
How to Order

55 - CG1 L N 25 55 - CDG1 L N 25

100 100
Cylinder stroke (mm)
Long Max Bore size Standard stroke (1) stroke (2) stroke (mm) (mm) (mm) (mm) 20 25 32 40 80 100 25, 50, 75, 100, 125, 150, 200 201 to 350 301 to 400 301 to 450

ATEX category 2 With auto switch


(magnet)

Mounting
B L F G U T D Basic Axial foot Front flange Rear flange Front trunnion Rear trunnion Clevis
Not available for bore sizes 80 and 100. Mounting brackets are included, not mounted.

25, 50, 75, 100, 125, 301 to 800 1500 150, 200, 250, 300 301 to 1200 50/63 301 to 1400 301 to 1500
Note 1) Other intermediate strokes can be manufactured upon receipt of order. Spacers are not used for the intermediate strokes. Note 2) Long stroke applies to the axial foot and the front flange style. If other mounting brackets are used or the length exceeds the stroke limit, the stroke should be determined based on the stroke selection table in the technical data.

Cushion
N A Rubber bumper Air cushion

Bore size
20 25 32 40 20mm 25mm 32mm 40mm 50 63 80 100 50mm 63mm 80mm 100mm

12

Series
Specifications
Bore size (mm) ATEX category 1) Action Lubrication Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Piston speed 20 25 32 40 50

55-CG1
63 80 100

II 2GDc

90C (T5) Ta 10 to 40C 110C (T4) Ta 40 to 60C

Double acting/Single rod Non-lube Air 1.5MPa 1.0MPa 0.05MPa Without auto switch: 10 to +70C (No freezing) With auto switch: 10 to +60C (No freezing) 50 to 1000mm/s Up to 1000
+1.4 0 mm,

50 to 700mm/s
+1.8 0 mm

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Stroke tolerance Thread tolerance Cushion

Up to 1200 JIS class 2

Up to 1000 +1.4 mm 0 Up to 1500


+1.8 0 mm

Rubber bumper/Air cushion Basic, Axial foot, Front flange, Rear flange, Front trunnion, Rear trunnion, Clevis (Used for changing the port location by 90 degrees.)

JIS symbol
Double acting

Mounting

Front/Rear trunnion styles are not available for bore sizes 80 and 100.
Note 1) This cylinder can be used in zones 1 and 21 and in zones 2 and 22. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zones 2 and 22 and not in zones 1 and 21.

Accessories
Mounting Standard Rod end nut Clevis pin Basic Axial foot Front flange Rear flange Front Rear trunnion trunnion Clevis

Single knuckle joint Double knuckle joint Option (With pins) Pivot bracket Rod boot

Pivot bracket is not available for bore sizes 80 and 100. Pins and snap rings for double knuckle joint are included, not mounted.

Mounting Bracket Part No.


Mounting bracket Axial foot Flange Trunnion Clevis Pivot bracket 20 25 32 Bore size (mm) 40 50 63 80 100 CG-L020 CG-L025 CG-L032 CG-L040 CG-L050 CG-L063 CG-L080 CG-L100 CG-F020 CG-F025 CG-F032 CG-F040 CG-F050 CG-F063 CG-F080 CG-F100 CG-T020 CG-T025 CG-T032 CG-T040 CG-T050 CG-T063 CG-D020 CG-D025 CG-D032 CG-D040 CG-D050 CG-D063 CG-D080 CG-D100 CG-020-24A CG-025-24A CG-032-24A CG-040-24A CG-050-24A CG-063-24A CG-080-24A CG-100-24A

Order two foot brackets per a cylinder. Clevis pins, snap rings and mounting bolts are attached for the clevis. Mounting bolts are attached for the foot type and the flange type.

13

ATEX Compliant Air Cylinder/Standard

Non-lube: 125, 140, 160, 180, 200, 250, 300 How to Order 55-CDS1
ATEX category 2 Build in magnet
D
125~300 125~200 Without magnet Built in magnet

Series

55-CS1
N 160 300 R
Cushion

Rod boot/Cushion
N R H
No cushion With cushion on rod side With cushion on head side With both sides cushion

Rod type
W
Single rod Double rod

Cylinder stroke (mm)


(Refer to following page for max. stroke table.)

Mounting
B L F G C D T
Basic Foot Front flange Rear flange Single clevis Double clevis Centre trunnion

Bore size Non-lube Tube material


Symbol Bore size Tube material 125 to 160 Aluminum tube 180 to 300 Steel tube 125 to 160 Steel tube

Non-lube

Mounting options for W type: B, L, F, T

125 140 160 180 200 250 300

125mm 140mm 160mm 180mm 200mm 250mm 300mm

Mounting Bracket Part No.


Bore size (mm) Foot Flange Single clevis Double clevis

125
CS1-L12 CS1-F12 CS1-C12 CS1-D12

140
CS1-L14 CS1-F14 CS1-C14 CS1-D14

160
CS1-L16 CS1-F16 CS1-C16 CS1-D16

180
CS1-L18 CS1-F18 CS1-C18 CS1-D18

200
CS1-L20 CS1-F20 CS1-C20 CS1-D20

250
CS1-L25 CS1-F25 CS1-C25 CS1-D25

300
CS1-L30 CS1-F30 CS1-C30 CS1-D30

Order 2 foot brackets for one cylinder. When ordering the double clevis, the clevis pin and the cotter pin (2 pcs.) are attached. For 55-CS1 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A54, A67, and F5P, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Indicator Type Reed auto switch Solid state auto switch Model No. D-A54 -588 D-A67 -588 D-F5P -588 Electrical entry Grommet Grommet Wiring (Output) 2-wiring 3-wiring (PNP) Load voltage DC 24V 12V 24V or less 24V 5V,12V Note 1) AC Lead wire (m) Note1) 0.5 () 3 (L) 5 (Z) Applicable load Relay PLC

Yes No Yes

IC circuit IC circuit

Lead wire length

When ordering a tie rod mounting type auto switch, also order a mounting bracket from the following list at the same time. Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, Auto switch mounting bracket/ Part no. (Tie rod mounting) which is the same category as the auto switch. Tube I.D. (mm) Auto switch

0.5m --- Nil (e.g.) D-A54-588 3 m --- L (e.g.) D-A54L-588 5 m --- Z (e.g.) D-A54Z-588

solid state auto switch is available after receiving an order.

Model D-A54 -588 D-A67 -588 D-F5P -588

125,140 BT-12

160 BT-16

180 BT-18A

200 BT-20

14

ATEX Compliant Air Cylinder/Standard


Specifications
Style ATEX category 1) Fluid Proof pressure 2) Max. operating pressure 2) Min. operating pressure Piston speed Cushion Ambient and fluid temperature Thread tolerance Stroke length tolerance (mm) 250 or less:
+1.0 0,

Series

55-CS1

Non-lube

II 2GDc

95C (T5) Ta 10 to 40C 115C (T4) Ta 40 to 60C

Air (Non-lube) 1.57MPa 0.97MPa 0.05MPa 50 to 500 mm/s None, air cushion 0 to 60C (No freezing) JIS class 2 251 to 1,000:
+2.2 0, +1.4 0,

1,001 to 1,500: +1.8 0


+2.6 0

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

1501 to 2000:

2001 to 2400:

Mounting

Basic, Foot, Front flange, Rear flange, Single clevis, Double clevis, Centre trunnion

Note 1) This cylinder can be used in zones 1 and 21 and in zones 2 and 22. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zones 2 and 22 and not in zones 1 and 21. Note 2) For the CDS1 diameter 180 and 200 the Proof pressure is 1.2MPa and the Max. operating pressure is 0.7MPa.

Accessories
Mounting Standard Clevis pin, Cotter pin Rod end nut Single knuckle joint Accessory Double knuckle joint (Knuckle pin, Cotter pin) Basic Foot Front flange Rear flange Single clevis Double clevis Centre trunnion

Symbol

Max. Stroke
Tube material Mounting bracket Bore Aluminum alloy Basic Rear flange Single clevis Double clevis Centre trunnion 1000 or less 1000 or less 1200 or less Carbon steel tube Basic Rear flange Single clevis Double clevis 1000 or less 1000 or less 1200 or less 1200 or less 1200 or less 1200 or less 1200 or less With auto switch

(mm)

Foot Front flange 1400 or less 1400 or less 1400 or less

Foot Front flange 1600 or less 1600 or less 1600 or less 2000 or less 2000 or less 2400 or less 2400 or less

B, G, C, D, T

L, F

125 140 160 180 200 250 300

1000 or less 1000 or less 1200 or less 1200 or less 998 or less -

1400 or less 1400 or less 1400 or less 1500 or less 998 or less -

15

ATEX Compliant Compact Cylinder/Standard: Double Acting Single Rod

Series
55ATEX category 2
Port size
M5 (12~25 only)

12, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 140, 160, 180, 200
How to Order

55-CQ2
30 D
Action
D Double acting C M

CDQ2 B 20

Body option
Standard (Rod end female thread) With rubber bumper Rod end male thread

G port (32~200 only)

Built-in magnet
None

Stroke (mm)
Bore size (mm) 12~16

Combination of body option is possible. (CM) Note2) All large bore cylinder 125 to 200 have C (rubber bumper) as standard.

Built-in magnet

Standard stroke (mm) 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300

Mounting
B A L Through -hole (Standard) Both ends tapped Foot F G D Front flange Rear flange Double clevis

20, 25 32~40 50~100 125~200

Only B type (Through-hole and both ends tapped) is available for large bore cylinder 125 to 200.

Bore size
12 16 20 25 32 12mm 16mm 20mm 25mm 32mm 40 50 63 80 100 40mm 50mm 63mm 80mm 100mm 125 140 160 180 200 125mm 140mm 160mm 180mm 200mm

Mounting Bracket Part No.


Bore size (mm) 12 16 20 25 32 40 50 63 80 100 Foot (4) CQ-L012 CQ-L016 CQ-L020 CQ-L025 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 Flange CQ-F012 CQ-F016 CQ-F020 CQ-F025 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-F080 CQ-F100 Double clevis (6) CQ-D012 CQ-D016 CQ-D020 CQ-D025 CQ-D032 CQ-D040 CQ-D050 CQ-D063 CQ-D080 CQ-D100

For 55-CDQ2 When using an Auto switch, select the appropriate switch from the following table and order it separately.

Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A73(H), A80(H), F7P(V), A93(V), A90(V), Z73, Z80, M9P(V) and Y7P(V), please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification. Also for D-M9P(V) type, see D-F9P(V) type specifications) Type Model No. Direct mounting Rail mounting 16 to 160 32 to 100 25 to 200 D-A73 -588 D-A93V -588 Indicator Electrical entry Wiring (Output) 24V 2-wiring 24V Load voltage DC 12V 48V or less 48V or less IC circuit IC circuit IC circuit solid state auto switch is available after receiving an order. Relay PLC 12V AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Note 4) 2 pcs. per cylinder should be ordered when foot brackets are required. Note 5) Each package contains the following parts. Foot, Flange: Body mounting bolt Double clevis: Clevis pin, C shape snap ring for axis, body mounting bolt Note 6) Package for double clevis contains clevis pin and snap ring.

Grommet (Perpendicular entry) D-A80 -588 D-A90V -588 Reed auto switch D-A73H -588 D-A93 -588 D-Z73 -588 Grommet (In-line entry) D-A80H -588 D-A90 -588 D-Z80 -588 Solid state auto switch

Yes No Yes No

24V or less 48V 24V or less 48V 24V 5V, 12V

Grommet D-F7PV -588 D-M9PV -588 D-Y7PV -588 (Perpendicular entry) Yes 3-wiring Grommet (PNP) D-F7P -588 D-M9P -588 D-Y7P -588 (In-line entry) 0.5m --- Nil (e.g.) D-A73-588 3 m --- L (e.g.) D-A73L-588 5 m --- Z (e.g.) D-A73Z-588

Lead wire length

Note 1)

Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, which is the same category as the auto switch.

When ordering a rail mounting type auto switch, also order a mounting bracket from the following list at the same time. Auto switch mounting bracket/ Part no. (Rail mounting type)

16

Auto switch Model D-A73 -588, D-A73H -588 D-A80 -588, D-A80H -588 D-F7P -588, D-F7PV -588

Part no. BQ-2 (32~160) BQ1 (12~25)

ATEX Compliant Compact Cylinder/Standard: Double Acting Single Rod

Series

55-CQ2

Style
Bore size (mm) Mounting
Through-hole (Standard)

12

16

20

25

32

40

50

63

80

100

125

140

160

180

200

Both ends tapped

Built-in magnet Pneumatic Piping Screw-in style M5 M5 M5 M5


M5 G1/8
(1)

G1/8 G1/4 G1/4 G3/8 G3/8 G3/8 G3/8 G3/8 G1/2 G1/2

Rod end male thread With rubber bumper


Note 1) Among those without an auto switch, only the 5mm stroke uses M5 piping.

Specifications
Bore size (mm) ATEX category 1) Style Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Cushion Rod end thread Tolerance of rod end thread Tolerance of stroke length Mounting Piston speed
+1.0 0

12

16

20

25

32

40

50

63

80

100

125

140

160

180

200

II 2GDc

85C (T6) Ta 10 to 40C 105C (T4) Ta 40 to 60C Air

Pneumatic (Non-lube) 1.5MPa 1.0MPa 0.07MPa 0.05MPa 10C to 60C (No freezing) None, rubber bumper Male thread, Female thread JIS class 2
+1.4 0

1.05MPa 0.7MPa

Rubber bumper

Through-hole, Both end tapped, Foot, Front flange, rear flange, Double clevis 50 to 500mm/s

Through-hole both end tapped 20 to 400 mm/s

Note 1) This cylinder can be used in zones 1 and 21 and in zones 2 and 22. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zones 2 and 22 and not in zones 1 and 21.

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

17

ATEX Compliant Dual Rod Cylinder

Series
55-CXS W M 20
ATEX category 2 Dual rod cylinder
W M L 6 6mm 10 10mm

6, 10, 15, 20, 25, 32


100

55-CXS/W
How to Order
Standard Strokes
CXS
Bore size Standard stroke 10, 20, 30, 40, 50 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 75 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 75, 80, 90, 100

(mm)

Available stroke range 60 to 100 80 to 150 110 to 150 110 to 200


(mm)

Type
Single rod Double rod

6 10 15 20 25 32
CXSW
Bore size

Bearing
Slide bearing Ball bushing bearing

Bore size
15 15mm 20 20mm 25 25mm 32 32mm

Standard stroke 10, 20, 30, 40, 50 10, 20, 30, 40, 50

Available stroke range 60 to 100 60 to 150

6 10 15 20 25 32
Bore size 10~20 25~32 25~32

Port thread type


Symbol

TF

Type M thread Rc G

10, 20, 30, 40, 50, 75, 100

110 to 200

CXS Specifications
Bore size (mm) ATEX category 1) Min. operating pressure Max. operating pressure Proof pressure Fluid Ambient and fluid temperature Piston speed Piping port Stroke adjustable range 30 to 300 30 to 800 mm/s mm/s M5 0.15MPa

10

15

20

25

32

II 2GDc
0.1MPa

65C (T6) Ta 10 to 40C 85C (T5) Ta 40 to 60C 0.05MPa 0.7MPa

1.05MPa Air (Non-lube) 10 to 60C (No freezing) 30 to 700 mm/s 30 to 600 mm/s Rc, G1/8

0 to 5 mm to the standard stroke Slide bearing, Ball bushing bearing (Same dimensions) Rubber bumper

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Bearing Cushion

CXSW Specifications
Bore size (mm) ATEX category 1) Fluid Min. operating pressure Max. operating pressure Proof pressure Ambient and fluid temperature Piston speed Piping port Stroke adjustable range Bearing Cushion M5 0.15MPa 0.7MPa 1.05MPa 10 to 60C (No freezing) 50 to 500mm/s Rc, G1/8 0 to 10mm (Extension side: 5mm, Retraction side: 5mm) Slide bearing, Ball bushing (Same dimensions) Rubber bumper

10

15

20

25

32

II 2GDc

65C (T6) Ta 10 to 40C 85C (T5) Ta 40 to 60C 0.1MPa

Air (Non-lube)

18

Note 1) This cylinder can be used in zones 1 and 21 and in zones 2 and 22. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zones 2 and 22 and not in zones 1 and 21.

ATEX Compliant Dual Rod Cylinder

Series

55-CXS

For 55-CXS When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-Z73, Z80, Y7P, and Y7PV, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Indicator Type Model No. D-Z73 -588 D-Z80 -588 D-Y7P -588 D-Y7PV -588 Electrical entry Wiring (Output) 2-wiring Load voltage DC 24V 24V or less 12V 48V 48V or less IC circuit Relay PLC Yes 3-wiring (PNP) 24V 5V,12V IC circuit AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Reed auto switch

Grommet (In-line) Grommet (In-line) Grommet (Perpendicular)

Yes No

Solid state auto switch

Lead wire length

0.5m --- Nil (e.g.) D-Z73-588 3 m --- L (e.g.) D-Z73L-588 5 m --- Z (e.g.) D-Z73Z-588

Note 1)

solid state auto switch is available after receiving an order.

Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, which is the same category as the auto switch.

19

ATEX Compliant Mechanically Jointed Rodless Cylinder

Series
Basic Type
Bore size
10 16 20 25 32 40 50 63 80 100
10mm 16mm 20mm 25mm 32mm 40mm 50mm 63mm 80mm 100mm Symbol

Basic Type/10, 16, 20, 25, 32, 40, 50, 63, 80, 100
How to Order

55-MY1B
300
Stroke
Refer to the standard stroke table below. Bore size 10~20 25~100

55-MY1B 25
Basic type Piping thread
TN TF
Type M thread Rc NPT G

ATEX category 2

Piping
G Standard type Centralized piping type

Standard strokes
Bore size (mm) Standard stroke (mm) 100, 200, 300, 400, 500, 600, 700 800, 900, 1000, 1200, 1400, 1600 1800, 2000

10, 16 20, 25, 32, 40, 50, 63, 80, 100

Specifications
Bore size (mm) ATEX category 1) Fluid Action Operating pressure range Proof pressure Ambient and fluid temperature Cushion Lubricaton 1000 or less+1.8 0 Stroke length tolerance 1001 to 3000+2.8 0 Port size
Rubber bumper
0.2 to 0.8MPa

10

16

20

25

32

40

50

63

80

100

II 2Gc

75C (T6) Ta 5 to 40C 95C (T5) Ta 40 to 60C Air

Double acting 0.1 to 0.8MPa 1.2MPa 5 to 60C Air cushion Non-lube 2700 or less+1.8, 2701 to 5000+2.8 0 0 Rc, NPT, G Rc, NPT, G 1/8 1/4 Rc, NPT, G 3/8 Rc, NPT, G 1/2

Symbol

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Front/Side ports

M5 x 0.8 100 to 500 mm/s

Operating piston speed

100 to 1000 mm/s

Note 1) This cylinder can be used in zone 1 and 2. For 55-MY1B If the cylinder is used with SMC category 3 type auto switch, then the When using an Auto switch, select the appropriate cylinder can only be used in zone 2 and not in zone 1. switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A93(V), A90(V), Z73, Z80, M9P(V) and Y7PV, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification. Also for D-M9P(V) type, see D-F9P(V) type specifications.) Lead wire (m) Load voltage Model No. Wiring Applicable Electrical entry Type 3 5 0.5 load DC AC (Output) (L) (Z) () 10 to 20 25 to 100 Yes 24V 12V D-A93V -588 Grommet (Perpendicular entry) No 24V or less 48V 48V or less D-A90V -588 IC circuit Reed 2-wiring auto switch D-A93 -588 Yes 24V 12V D-Z73 -588 Grommet Relay (In-line entry) No IC circuit 24V or less 48V 48V or less D-A90 -588 D-Z80 -588 PLC Solid state auto switch D-M9PV -588 D-Y7PV -588 D-M9P -588 Grommet (Perpendicular entry) Yes 3-wiring Grommet (PNP) D-Y7P -588 (In-line entry) Indicator 24V 5V, 12V Note 1) IC circuit solid state auto switch is available after receiving an order.

Lead wire length

0.5m --- Nil (e.g.) D-A93-588 3 m --- L (e.g.) D-A93L-588 5 m --- Z (e.g.) D-A93Z-588

Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, which is the same category as the auto switch.

20

ATEX Compliant Mechanically Jointed Rodless Cylinder

Series

Slide Bearing Type/16, 20, 25, 32, 40, 50, 63


How to Order
Slide Bearing Guide Type

55-MY1M
55-MY1M 25
Slide bearing guide type Stroke Piping
G

300
Refer to the standard stroke table below. Standard type Centralized piping type

ATEX category 2

Standard strokes
Bore size (mm) Standard stroke (mm) 100, 200, 300, 400, 500, 600, 700 800, 900, 1000, 1200, 1400, 1600 1800, 2000

Bore size
16 20 25 32 40 50 63
16mm 20mm 25mm 32mm 40mm 50mm 63mm

Piping
Symbol

16 20, 25, 32, 40 50, 63

TN TF

Type M thread Rc NPT G

Bore size 16~20 25~63

Specifications
Bore size (mm) ATEX category 1) Fluid Action Operating pressure range Proof pressure Ambient and fluid temperature Cushion Lubrication

16

20

25

32

40

50

63

II 2Gc

75C (T6) Ta 5 to 40C 95C (T5) Ta 40 to 60C Air Double acting

0.15 to 0.8MPa 1.2MPa 5 to 60C Air cushion Non-lube


1000 or less+1.8 0 1001 to 3000+2.8 0

Symbol

Stroke length tolerance Port size Front/Side ports

2700 or less+1.8, 2701 to 5000+ 2.8 0 0


Rc, NPT, G 1/8 100 to 1000 mm/s Rc, NPT, G 1/4 Rc, NPT, G 3/8

M5 x 0.8

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Operating piston speed

Note 1) This cylinder can be used in zones 1 and 2. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zone 2 and not in zone 1.

For 55-MY1M When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A93(V), A90(V), Z73, Z80, M9P(V) and Y7PV, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification. Also for D-M9P(V) type, see D-F9P(V) type specifications.) Type Model No. 16 to 20 D-A93V -588 D-A90V -588 Reed auto switch D-A93 -588 D-A90 -588 Solid state auto switch D-Z73 -588 D-Z80 -588 25 to 63 Indicator Electrical entry Wiring (Output) 24V 2-wiring 24V Load voltage DC 12V 48V or less 48V or less IC circuit IC circuit IC circuit solid state auto switch is available after receiving an order. Relay PLC 12V AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Yes Grommet (Perpendicular entry) No Grommet (In-line entry) Yes No

24V or less 48V 24V or less 48V 24V 5V, 12V

D-M9PV -588 D-Y7PV -588 D-M9P -588

Grommet (Perpendicular entry) Yes 3-wiring Grommet (PNP) D-Y7P -588 (In-line entry)

Lead wire length

0.5m --- Nil (e.g.) D-A93-588 3 m --- L (e.g.) D-A93L-588 5 m --- Z (e.g.) D-A93Z-588

Note 1)

Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, which is the same category as the auto switch.

21

ATEX Compliant Mechanically Jointed Rodless Cylinder

Series
High Precision Guide Type
ATEX category 2

High Precision Guide Type/10, 16, 20, 25, 32, 40


How to Order

55-MY1H
300
Stroke High precision guide type Bore size Piping
G Refer to the standard stroke table below.

55-MY1H 25

Standard strokes
Bore size (mm) Standard stroke

(mm)

Maximum manufacturable stroke (mm) 1000 1500

10, 16, 20 25, 32, 40

50, 100, 150, 200, 300, 350, 400, 450, 500, 550, 600

10 16 20 25 32 40

10mm 16mm 20mm 25mm 32mm 40mm

Standard type Centralized piping type

Piping
Symbol

TN TF

Type M thread Rc NPT G

Bore size 10~20 25~40

Specifications
Bore size (mm) ATEX category 1) Fluid Action Operating pressure range Proof pressure Ambient and fluid temperature Cushion Lubrication
Rubber bumper
0.2 to 0.8MPa

10

16

20

25

32

40

II 2Gc

75C (T6) Ta 5 to 40C 95C (T5) Ta 40 to 60C Air Double acting 0.1 to 0.8MPa 1.2MPa 5 to 60C Air cushion Non-lube +1.8 0

Symbol

Stroke length tolerance Port size Front/Side ports 100 to 500 mm/s M5 x 0.8

Rc, NPT, G 1/8 100 to 1000 mm/s

Rc, NPT, G 1/4

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Operating piston speed

Note 1) This cylinder can be used in zone 1 and 2. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zone 2 and not in zone 1.

For 55-MY1H When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A93(V), A90(V), Z73, Z80, M9P(V) and Y7PV, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification. Also for D-M9P(V) type, see D-F9P(V) type specifications.) Type Model No. 10 to 20 D-A93V -588 D-A90V -588 Reed auto switch D-A93 -588 D-A90 -588 Solid state auto switch D-Z73 -588 D-Z80 -588 25 to 40 Indicator Electrical entry Wiring (Output) 24V 2-wiring 24V Load voltage DC 12V 48V or less 48V or less IC circuit IC circuit IC circuit solid state auto switch is available after receiving an order. Relay PLC 12V AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Yes Grommet (Perpendicular entry) No Grommet (In-line entry) Yes No

24V or less 48V 24V or less 48V 24V 5V, 12V

D-M9PV -588 D-Y7PV -588 D-M9P -588

Grommet (Perpendicular entry) Yes 3-wiring Grommet (PNP) D-Y7P -588 (In-line entry)

Lead wire length

0.5m --- Nil (e.g.) D-A93-588 3 m --- L (e.g.) D-A93L-588 5 m --- Z (e.g.) D-A93Z-588

Note 1)

Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, which is the same category as the auto switch.

22

23

Series 55-CRB1
Sizes: 50, 63, 80, 100 How to Order

ATEX Compliant Vane Type: Rotary Actuator

55-CRB1 B W 80
ATEX category 2
Size
50 63 80 100

90 S

Mounting
B L Basic type Foot type

Thread Port
Rc(PT)

XF XN

G(PF) NPT

Refer to Table 1 below if only foot assembly is required separately. Foot accesory is shipped together with the actuator but not mounted on it.

Table 1: Foot assembly part no.


Model CRB1LW 50 CRB1LW 63 CRB1LW 80 CRB1LW100 Unit part no. P411020-5 P411030-5 P411040-5 P411050-5

Shaft type
W Double shaft (long shaft key & four chamfers)

Connecting port position Rotation


E Side ports Axial ports
Bolt

Classification

Symbol Single vane 90 90 180 180 270 270 100 100 190 190 280 280 S D

Double vane 90 100

Optional Standard

Vane type
Single vane Double vane

A port

B port

B port

A port

Side ports

Axial ports
Body end of the short-shaft side

24

Rotary Actuator

Vane Type

Series 55-CRB1

Specifications
Radial force Model (Size) Vane type
ATEX category
1)
+4 0 +4 0

CRB1BW50 CRB1BW63 CRB1BW80 CRB1BW100 CRB1BW50 CRB1BW63 CRB1BW80 CRB1BW100


Single vane (S) Double vane (D) 90C (T5) Ta 5 to 40C 110C (T4) Ta 40 to 60C 90 100
+4 0 +4 0

II 2GDc
90 , 180 , 270 +4 100 +4 , 190 0 , 280 +4 0 0
+4 0

Rotation Fluid
Size: 100 Size: 80

Standard Optional

Air (non-lube)
1.5MPa 5 to 60C 1.0MPa 0.15MPa 0.1 to 1 0.082 245 196 0.12 390 340 0.398 490 490 0.6 588 539 0.112 245 196 0.16 390 340 0.54 490 490 0.811 588 539

Proof pressure (MPa) Ambient and fluid temperature

Thr

ust

e orc

Size: 50

Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90)
Allowable kinetic energy (J)

JIS symbol

Allowable Shaft radial load (N) load Allowable thrust load (N) Bearing type Port position Size Side ports Axial ports

Ball bearing

Side ports or axial ports


Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4

Mounting
Note 1) This actuator can be used in zones 1 and 2.

Basic, Foot

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

25

ATEX Compliant Rotary Actuator: Vane Type

Series 55-CRB2
Sizes: 10, 15, 20, 30, 40 How to Order

55-CRB2 B W 10
ATEX category 2
Size
10 15 20 30 40

180 S E
Connecting port position
E Side ports Axial ports Side ports Axial ports

Mounting
Basic type B Flange type F1) When ordering "F" mounting type, flange is shipped together with the actuator, but not mounted. Flange can be mounted at 60 degrees intervals. Note1) Not available for size 40.

Vane type
S D Single vane Double vane Fittings are sold separately.

Standard Shaft type


W Double shaft with single flat (sizes 10 to 30) Long shaft key, Short shaft with single flat (size 40)

Rotation
Vane type Symbol Single vane Double vane
90 180 270 90 100

Rotation
90 180 270 90 100

Flange Assembly Part No.


Model CRB2FW10 CRB2FW15 CRB2FW20 CRB2FW30 Assembly part no. P211070-2 P211090-2 P211060-2 P211080-2

26

Rotary Actuator

Vane Type

Series 55-CRB2

Radial force

Single Vane Specifications


Model (Size) Vane type
ATEX category
1)

CRB2BW10-S CRB2BW15-S CRB2BW20-S CRB2BW30-S CRB2BW40-S Single vane 130C (T4) Ta 5 to 40C

II 2Gc

Thr

ust

e orc

Rotation Fluid Proof pressure (MPa) Ambient and fluid temperature Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90) Note 2) Allowable kinetic energy (J) Shaft Allowable radial load (N) load Allowable thrust load (N) Bearing type Port position Side ports Size Axial ports Shaft type

90, 180 270 90, 180 270 1.05

150C (T3) Ta 40 to 60C 90, 180, 270 Air (non-lube) 1.5

5 to 60C
0.7 0.2 0.03 to 0.3 0.00015 15 10 0.001 15 10 0.003 25 20 1.0 0.15 0.04 to 0.3 0.02 30 25 0.07 to 0.5 0.04 60 40

Ball bearing Side ports or axial ports


M5 M3 M3 M5 M3 M5
Double shaft (Long shaft key & single flat)

M5 Double shaft (with single flat on both shafts)

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Mounting
Note 1) This rotary actuator can be used in zones 1 and 2.

Basic, Flange

Basic

Double Vane Specifications


Model (Size) Vane type
ATEX category
1)

CRB2BW10-D CRB2BW15-D CRB2BW20-D CRB2BW30-D CRB2BW40-D Double vane 130C (T4) Ta 5 to 40C 150C (T3) Ta 40 to 60C 90, 100 1.5

II 2Gc

Rotation

JIS symbol

Fluid Proof pressure (MPa) Ambient and fluid temperature Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90) Note 2) Allowable kinetic energy (J) Shaft Allowable radial load (N) load Allowable thrust load (N) Bearing type Port position Port size (Side ports, Axial ports) Shaft type Mounting
M3 0.0003 15 10 0.2 0.03 to 0.3 0.0012 15 10 0.7 1.05

Air (non-lube) 5 to 60C


1.0 0.15 0.04 to 0.3 0.0033 25 20 Ball bearing 0.02 30 25 0.07 to 0.5 0.04 60 40

Side ports or axial ports


M5

Double shaft (double shaft with single flat on both shafts) Basic, Flange
Basic

The following notes apply to both Single and Double Vane Specification tables above. Note 2) Make sure to operate within the speed regulation range. Exceeding the maximum speed (0.3 sec/90) can cause the unit to stick or not operate.

27

ATEX Compliant Rotary Actuator: Free-Mounting Type

Series

Sizes: 10, 15, 20, 30, 40

55-CRBU2
180 S E
Connecting port position
E Side ports Axial ports Axial ports

How to Order

55-CRBU2 W 10
ATEX category 2
Free-mounting

Side ports

Size
10 15 20 30 40

Shaft type
W Double shaft with single flat (sizes 10 to 30) Long shaft key, Short shaft with single flat (size 40) Single vane Double vane

Vane type
S D Single vane Double vane

Fittings are sold separately.

Rotation
Vane type Symbol Rotation
90 180 270 90 100 90 180 270 90 100

28

Free-Mounting Type

Rotary Actuator

Series 55-CRBU2

Radial force

Single Vane Specifications


Model (Size)
ATEX category
1)

CRBU2W10-S CRBU2W15-S CRBU2W20-S CRBU2W30-S CRBU2W40-S 130C (T4) Ta 5 to 40C

II 2Gc

Rotation
or st f ce

150C (T3) Ta 40 to 60C 90, 180, 270 Air (non-lube) 1.5 5 to 60C 1.0 0.15 0.04 to 0.3 0.003 25 20 Ball bearing 0.02 30 25 0.07 to 0.5 0.04 60 40

Fluid Proof pressure (MPa) Ambient and fluid temperature Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90) Note 2) Allowable kinetic energy (J) Shaft Allowable radial load (N) load Allowable thrust load (N) Bearing type
0.00015 15 10 0.2 0.03 to 0.3 0.001 0.7 1.05

Thr

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Port position Port size Shaft type


Side ports Axial ports

Side ports or axial ports M5


M3 M5 Double shaft (Double shaft with single flat on both shafts)
Double shaft (Long shaft key & Single flat)

Note 1) This rotary actuator can be used in zone 1 and 2.

Double Vane Specifications


Model (Size)
ATEX category
1)

CRBU2W10-D CRBU2W15-D CRBU2W20-D CRBU2W30-D CRBU2W40-D 130C (T4) Ta 5 to 40C

II 2Gc

Rotation Fluid Proof pressure (MPa) Ambient and fluid temperature Max. operating pressure (MPa)
0.7 0.2 0.0003 15 10 0.03 to 0.3 0.0012 1.05

150C (T3) Ta 40 to 60C 90, 100 1.5

Air (non-lube) 5 to 60C 1.0 0.15 0.04 to 0.3 0.0033 25 20 Ball bearing 0.02 30 25 0.07 to 0.5 0.04 60 40

JIS symbol

Min. operating pressure (MPa) Speed regulation range (sec/90) Note 2) Allowable kinetic energy (J) Shaft Allowable radial load (N) load Allowable thrust load (N) Bearing type Port position Port size Shaft type Side ports Axial ports

Side ports or axial ports M5


M3 M5 Double shaft (Double shaft with single flat on both shafts)
Double shaft (Long shaft key & Single flat)

The following notes apply to both Single and Double Vane Specification tables above. Note 2) Make sure to operate within the speed regulation range. Exceeding the maximum speeds can cause the unit to stick or not operate.

29

ATEX Compliant Compact Rotary Actuator Rack-and-Pinion Type

Series
ATEX category 2
Built-in magnet
D

55-CRQ2
How to Order

55-CDRQ2B S 20
None Magnet

90
Air cushion
Air cushion Without 20, 30, 40 Without With C Sizes 10, 15

Shaft type
S W Single shaft with one chamfer Single shaft with key Double shaft with one chamfer Double shaft with key 10, 15 20~40 10, 15 20~40

Size
10 15 20 30 40

Rotation Port thread type


Size 10, 15 20, 30, 40 Port thread M5 Nil Rc1/8 Nil TF G1/8 TN NPT1/8 TT NPTF1/8

90 180

80 to 100 170 to 190

Specifications
Size ATEX category 1) Fluid Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Cushion Angle adjustment Rotation Port size Mounting brackets Output Nm at 0.5 MPa 0.3 0.75 M5 x 0.8 1.8 Rubber bumper 5 80 to 100, 170 to 190 Rc, G, NPT, NPT(F) 1/8 Basic type 3.1 5.3 0.7MPa 0.15MPa 10 15 20 30 40

II 2Gc

70C (T6) Ta 0 to 40C 90C (T5) Ta 40 to 60C 1MPa 0.1MPa

Air (unlubricated)

0 to 60C (with no freezing) None, Air cushion

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Note 1) This cylinder can be used in zones 1 and 2. If the cylinder is used with SMC category 3 type auto switch, then the cylinder can only be used in zone 2 and not in zone 1.

JIS symbol

Allowable Kinetic Energy and Rotation Time Adjustment Range


Allowable kinetic energy Size 10 15 20 30 40 Allowable kinetic energy (J) Without cushion Rubber bumper With air cushion 0.25 x 10- 0.025 0.048 0.081 0.39 x 10- 0.12 0.25 0.40 Cushion angle 40 40 40
Stable operational rotation time adjustment range

Rotation time (s/90) 0.2 to 0.7 0.2 to 0.7 0.2 to 1 0.2 to 1 0.2 to 1

) Allowable kinetic energy with cushion


Maximum energy absorption with optimal adjustment of cushion needle

30

Series 55-CRQ2
For 55-CRQ2 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-A93A, A90, A93V, A90V, M9P, and M9PV, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Indicator Type Model No. D-A93 -588 Reed auto switch D-A90 -588 D-A93V -588 D-A90V -588 Solid state auto switch Lead wire length D-M9P -588 D-M9PV -588 Electrical entry Grommet (In-line) Grommet (Perpendicular) Grommet (In-line) Grommet (Perpendicular) Wiring (Output) 24V 2-wiring 24V Load voltage DC 12V 48V or less 48V or less IC circuit IC circuit IC circuit solid state auto switch is available after receiving an order. Relay PLC 12V AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Yes No Yes No Yes 3-wiring (PNP)

24V or less 48V 24V or less 48V 24V 5V, 12V

0.5m --- Nil (e.g.) D-A93-588 3 m --- L (e.g.) D-A93L-588 5 m --- Z (e.g.) D-A93Z-588

Note 1)

Note 2) When mounting an auto switch on a 55- series (Category 2) Model, the ATEX category of the auto switch cylinder changes to Category 3, which is the same category as the auto switch.

31

Series 56-CRB1
Sizes: 50, 63, 80, 100 How to Order

ATEX Compliant Vane Type: Rotary Actuator

56-CDRB1 B W 80
ATEX category 3
With auto switch unit
D Without switch unit With switch unit

90 S

Size
50 63 80 100

Mounting Table 1: Foot assembly part no.


Model CRB1LW 50 CRB1LW 63 CRB1LW 80 CRB1LW100 Unit part no. P411020-5 P411030-5 P411040-5 P411050-5 B L Basic type Foot type

Thread Port
Rc(PT)

XF XN

G(PF) NPT

Refer to Table 1 below if only foot assembly is required separately. Foot accesory is shipped together with the actuator but not mounted on it.

Connecting port position


E Side ports Axial ports
Bolt

Shaft type
W Double shaft (long shaft key & four chamfers)

Rotation
Classification

Symbol Single vane 90 90 180 180 270 270 100 100 190 190 280 280 S D

Double vane 90 100

Optional Standard

A port

B port

B port

A port

Side ports

Axial ports
Body end of the short-shaft side

Vane type
Single vane Double vane

For 56-CDRB1 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-R73, R80, and S7P, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Indicator Type Model No. D-R73 -588 D-R80 -588 Electrical entry Wiring (Output) 2-wiring Load voltage DC AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Reed auto switch

Grommet (In-line)

Yes No 24V 5V,12V 24V or less IC circuit Relay PLC

Solid state auto switch

D-S7P -588

Grommet (In-line)

Yes

3-wiring (PNP)

24V 5V,12V

IC circuit

Lead wire length

0.5m --- Nil (e.g.) D-R73-588 3 m --- L (e.g.) D-R73L-588 5 m --- Z (e.g.) D-R73Z-588

Note) Refer to the table below for the ATEX temperature class of a rotary actuator (56-CDRB1) with an autoswitch mounted to it.

Normal temperature range (5C to 40C) Special temperature range (40C to 60C)

Rotary Actuator T6 T4

Auto switch T5 T5

Rotary actuator with auto switch Equivalent to T5 Equivalent to T4

32

Rotary Actuator

Vane Type

Series 56-CRB1

Specifications
Radial force Model (Size) Vane type
ATEX category
1)
+4 0 +4 0 +4 0

CRB1BW50 CRB1BW63 CRB1BW80 CRB1BW100 CRB1BW50 CRB1BW63 CRB1BW80 CRB1BW100


Single vane (S) Double vane (D) 84C (T6) Ta 5 to 40C 104C (T4) Ta 40 to 60C 90 100
+4 0 +4 0

II 3G
90 , 180 , 270 +4 100 +4 , 190 0 , 280 +4 0 0

Rotation Fluid
Size: 100 Size: 80

Standard Optional

Air (non-lube)
1.5MPa 5 to 60C 1.0MPa 0.15MPa 0.1 to 1 0.082 245 196 0.12 390 340 0.398 490 490 0.6 588 539 0.112 245 196 0.16 390 340 0.54 490 490 0.811 588 539

Proof pressure (MPa) Ambient and fluid temperature

Thr

ust

e orc

Size: 50

Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90)
Allowable kinetic energy (J)

JIS symbol

Allowable Shaft radial load (N) load Allowable thrust load (N) Bearing type Port position Size Side ports Axial ports

Ball bearing

Side ports or axial ports


Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4

Mounting

Basic, Foot

Note 1) This actuator can be used in zone 2 and not in zone 1.

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

33

ATEX Compliant Rotary Actuator: Vane Type

Series 56-CRB2
Sizes: 10, 15, 20, 30, 40 How to Order

56-CDRB2 B W 10
ATEX category 3

180 S
Connecting port position
Body size Axial position E E not possible with switch unit

With auto switch unit


D Without switch unit With switch unit

Size
10 15 20 30 40

Mounting
Basic type B Flange type F1) When ordering "F" mounting type, flange is shipped together with the actuator, but not mounted. Flange can be mounted at 60 degrees intervals. Note1) Not available for size 40.

Vane type
S D Single vane Double vane

Standard Shaft type


W Double shaft with single flat (sizes 10 to 30) Long shaft key, Short shaft with single flat (size 40)

Flange Assembly Part No.


Rotation
Vane type Symbol Single vane Double vane
90 180 270 90 100

Model CRB2FW10 CRB2FW15 CRB2FW20 CRB2FW30

Assembly part no. P211070-2 P211090-2 P211060-2 P211080-2

Rotation
90 180 270 90 100

For 56-CDRB2 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-93A, 90A, S9P, S9PV, R73, R80, and S7P, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Applicable Size Indicator Type Reed auto switch Model No. D-93A -588 D-90A -588 -588 -588 -588 -588 -588 Electrical entry Grommet (In-line) Grommet (In-line) Wiring (Output) 2-wiring 24V 24V Load voltage DC 5V, 12V 24V or less 5V, 12V 5V, 12V 24V or less 5V, 12V IC circuit IC circuit IC circuit IC circuit IC circuit Relay PLC AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Yes No

10, 15

20, 30, 40

Solid state D-S9P auto switch D-S9PV D-R73 Reed auto switch D-R80 Solid state D-S7P auto switch

3-wiring Yes (PNP) Grommet (Perpendicular) Yes Grommet 2-wiring (In-line) No Grommet Yes 3-wiring (In-line) (PNP)

24V

Lead wire length

0.5m --- Nil (e.g.) D-R73-588 3 m --- L (e.g.) D-R73L-588 5 m --- Z (e.g.) D-R73Z-588

Note) Refer to the table below for the ATEX temperature class of a rotary actuator (56-CDRB1) with an autoswitch mounted to it.

Normal temperature range (5C to 40C) Special temperature range (40C to 60C)

Rotary Actuator T5 T4

Auto switch T5 T5

Rotary actuator with auto switch Equivalent to T5 Equivalent to T4

34

Rotary Actuator

Vane Type

Series 56-CRB2

Radial force

Single Vane Specifications


Model (Size) Vane type
ATEX category
1)

CRB2BW10-S CRB2BW15-S CRB2BW20-S CRB2BW30-S CRB2BW40-S Single vane 100C (T5) Ta 5 to 40C

II 3G

Thr

us

rc t fo

Rotation Fluid Proof pressure (MPa) Ambient and fluid temperature Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90) Note 2) Allowable kinetic energy (J) Shaft Allowable radial load (N) load Allowable thrust load (N) Bearing type Port position Side ports Size Axial ports Shaft type

90, 180 270 90, 180 270 1.05

120C (T4) Ta 40 to 60C 90, 180, 270 Air (non-lube) 1.5

5 to 60C
0.7 0.2 0.03 to 0.3 0.00015 15 10 0.001 15 10 0.003 25 20 1.0 0.15 0.04 to 0.3 0.02 30 25 0.07 to 0.5 0.04 60 40

Ball bearing Side ports or axial ports


M5 M3 M3 M5 M3 M5
Double shaft (Long shaft key & single flat)

M5 Double shaft (with single flat on both shafts)

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Mounting Auto switch


Note 1) This rotary actuator can be used in zone 2.

Basic, Flange
Mountable (Side ports only)

Basic

Double Vane Specifications


Model (Size) Vane type
ATEX category
1)

CRB2BW10-D CRB2BW15-D CRB2BW20-D CRB2BW30-D CRB2BW40-D Double vane 100C (T5) Ta 5 to 40C 120C (T4) Ta 40 to 60C 90, 100 1.5

II 3G

Rotation

JIS symbol

Fluid Proof pressure (MPa) Ambient and fluid temperature Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90) Note 2) Allowable kinetic energy (J) Shaft Allowable radial load (N) load Allowable thrust load (N) Bearing type Port position Port size (Side ports, Axial ports) Shaft type Mounting Auto switch
M3 0.0003 15 10 0.2 0.03 to 0.3 0.0012 15 10 0.7 1.05

Air (non-lube) 5 to 60C


1.0 0.15 0.04 to 0.3 0.0033 25 20 Ball bearing 0.02 30 25 0.07 to 0.5 0.04 60 40

Side ports or axial ports


M5

Double shaft (double shaft with single flat on both shafts) Basic, Flange
Mountable (Side ports only) Basic

The following notes apply to both Single and Double Vane Specification tables above. Note 2) Make sure to operate within the speed regulation range. Exceeding the maximum speed (0.3 sec/90) can cause the unit to stick or not operate.

35

ATEX Compliant Rotary Actuator: Free-Mounting Type


Sizes: 10, 15, 20, 30, 40

Series

56-CRBU2
How to Order

56-CDRBU2 W 10
ATEX category 3

180 S
Connecting port position

With auto switch unit


D Without switch unit With switch unit

Size
10 15 20 30 40

Body size Axial position E E not possible with switch unit

Vane type
S D Single vane Double vane

Free-mounting

Shaft type
W Double shaft with single flat (sizes 10 to 30) Long shaft key, Short shaft with single flat (size 40)

Rotation
Vane type Symbol Rotation Single vane Double vane
90 180 270 90 100 90 180 270 90 100

For 56-CDRBU2 When using an Auto switch, select the appropriate switch from the following table and order it separately. Applicable auto switch specifications Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10C Ta +60C IP67) For detailed specifications on the D-93A, 90A, S9P, S9PV, R73, R80, and S7P, please refer to the relevant pages in Best Pneumatics. (Note: Reed auto switches for AC 100V and DC 100V are not within the specification.) Applicable Size Indicator Type Reed auto switch Model No. D-93A -588 D-90A -588 -588 -588 -588 -588 -588 Electrical entry Grommet (In-line) Grommet (In-line) Wiring (Output) 2-wiring 24V 24V 24V 24V Load voltage DC 5V, 12V 24V or less 5V, 12V 5V, 12V 24V or less 5V, 12V IC circuit IC circuit IC circuit IC circuit Relay PLC AC 0.5 () Lead wire (m) 3 (L) 5 (Z) Applicable load

Yes No

10, 15

20, 30, 40

Solid state D-S9P auto switch D-S9PV D-R73 Reed auto switch D-R80 Solid state D-S7P auto switch

3-wiring Yes (PNP) Grommet (Perpendicular) Yes Grommet 2-wiring (In-line) No Grommet 3-wiring Yes (In-line) (PNP)

Lead wire length

0.5m --- Nil (e.g.) D-R73-588 3 m --- L (e.g.) D-R73L-588 5 m --- Z (e.g.) D-R73Z-588

Note) Refer to the table below for the ATEX temperature class of a rotary actuator (56-CDRB1) with an autoswitch mounted to it.

Normal temperature range (5C to 40C) Special temperature range (40C to 60C)

Rotary Actuator T5 T4

Auto switch T5 T5

Rotary actuator with auto switch Equivalent to T5 Equivalent to T4

36

Free-Mounting Type

Rotary Actuator

Series 56-CRBU2

Radial force

Single Vane Specifications


Model (Size)
ATEX category 1) CRBU2W10-S CRBU2W15-S CRBU2W20-S CRBU2W30-S CRBU2W40-S 100C (T5) Ta 5 to 40C

II 3G

Rotation
or st f ce

120C (T4) Ta 40 to 60C 90, 180, 270 Air (non-lube) 1.5 5 to 60C 1.0 0.15 0.04 to 0.3 0.003 25 20 Ball bearing 0.02 30 25 0.07 to 0.5 0.04 60 40

Fluid Proof pressure (MPa) Ambient and fluid temperature Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90) Note 2) Allowable kinetic energy (J) Shaft Allowable radial load (N) load Allowable thrust load (N) Bearing type
0.00015 15 10 0.2 0.03 to 0.3 0.001 0.7 1.05

Thr

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Port position Port size Shaft type


Side ports Axial ports M3

Side ports or axial ports M5


M5
Double shaft (Long shaft key & Single flat)

Double shaft (Double shaft with single flat on both shafts)

Note 1) This rotary actuator can be used in zones 2 and not in zone 1.

Double Vane Specifications


Model (Size)
ATEX category
1)

CRBU2W10-D CRBU2W15-D CRBU2W20-D CRBU2W30-D CRBU2W40-D 100C (T5) Ta 5 to 40C

II 3G

Rotation Fluid Proof pressure (MPa) Ambient and fluid temperature Max. operating pressure (MPa) Min. operating pressure (MPa) Speed regulation range (sec/90) Note 2) Allowable kinetic energy (J) Shaft Allowable radial load (N) load Allowable thrust load (N) Bearing type Port position Port size Shaft type Side ports Axial ports
M3 0.0003 15 10 0.2 0.03 to 0.3 0.0012 1.05

120C (T4) Ta 40 to 60C 90, 100 1.5

Air (non-lube) 5 to 60C 0.7 1.0 0.15 0.04 to 0.3 0.0033 25 20 Ball bearing 0.02 30 25 0.07 to 0.5 0.04 60 40

JIS symbol

Side ports or axial ports M5


M5
Double shaft (Long shaft key & Single flat)

Double shaft (Double shaft with single flat on both shafts)

The following notes apply to both Single and Double Vane Specification tables above. Note 2) Make sure to operate within the speed regulation range. Exceeding the maximum speeds can cause the unit to stick or not operate.

37

ATEX Compliant Solid-state Switch / Direct Mounting

D-M9N(V)-588D-M9P(V)-588D-M9B(V)-588
Auto Switch Specifications
PLC: Programmable Logic Controller

D-M9/D-M9V (With indicator light)


Auto switch part no. Electrical entry direction ATEX Category Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Indicator light NPN

D-M9N
In-line

D-M9NV
Perpendicular

D-M9P
In-line

D-M9PV
Perpendicular

D-M9B
In-line

D-M9BV
Perpendicular

II 3GD EEx nA II T5 X -10CTa+60C IP67


3-wire PNP IC circuit, Relay, PLC 5, 12, 24 VDC (4.5 to 28 VDC) 10 mA or less 28 VDC or less 40 mA or less 0.8 V or less 100 A or less at 24 VDC Red LED illuminates up. 2-wire 24 VDC relay, PLC 24 VDC (10 to 28 VDC) 2.5 to 40 mA 4 V or less 0.8 mA or less

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Lead wire: oil-proof heavy-duty vinyl cord 2.7 x 3.2 elipse, 0.15 mm2, 2 cores (D-M9B), or 3 cores (D-M9N and D-M9P) This category 3 type autoswitch can only be used in zones 2 and 22.

How to Order Internal circuits


D-M9N, D-M9NV
DC (+) Brown

Standard Model Number

D-M9 N V L -588
Series Model Number Suffix for ATEX certified CAT.3 Lead wire length
Nil L Z 0.5m 3m 5m

Switch main circuit

OUT Black

DC () Blue

Wiring and output


N P B
3-wire NPN 3-wire PNP 2-wire

D-M9P, D-M9PV
DC (+) Brown

Electrical entry
Nil V In-line Perpendicular

Switch main circuit

OUT Black DC () Blue

D-M9B, D-M9BV
OUT (+) Brown

Switch main circuit

OUT () Blue

38

ATEX Compliant Reed Switch/Band Mounting

D-C73/D-C80-588
Grommet
Specifications
D-C7 (With indicator light)
Auto switch model number ATEX Category Application Load voltage Max. load current and range Contact protection circuit Internal voltage drop Indicator light

PLC: Programmable Logic Controller

D-C73
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC 24V DC 5 to 40mA None 2.4V ON: When red light emitting diode

D-C8 (Without indicator light)


Auto switch model number ATEX Category Application Load voltage Max. load current Contact protection circuit 24V
AC DC

D-C80
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC/IC circuit or less None
AC 48V DC

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

50mA

40mA

Internal Circuit ( ): If not applicable for IEC Standard


D-C73
LED Brown(Red) Reed switch Resistance Contact protective box CD-P11 Zener diode
Blue(Black) OUT(+) Brown(Red)

1 or less (Including 3m lead wire) Internal resistance This category 3 type autoswitch can only be used in zones 2 and 22.

How to order

CD-P12

OUT() Blue(Black)

D-C80
Reed switch Contact protective box CD-P11 CD-P12
OUT( ) Blue(Black) OUT() Brown(Red)

D-C

-588
Suffix for ATEX certified CAT.3

Note) q In the case operation load is an inductive load. w In the case the wiring length to load is more than 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.

Switch No.
73 80 With indicator lamp Without indicator lamp

Lead wire length


No number L Z 0.5m 3m 5m (Except D-C80)

39

ATEX Compliant Reed Switch/Rail Mounting

D-A73(H)/D-A80(H)-588
Grommet
Specifications D-A7 (With indicator light)
Auto switch model number ATEX Category Application Load voltage Load current range Contact protection circuit Internal voltage drop Indicator light PLC: Programmable Logic Controller

D-A73
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC 24V DC 5 to 40mA None 2.4V ON: When red light emitting diode

D-A8 (Without indicator light)


Auto switch model number ATEX Category Application Load voltage Max. load current Contact protection circuit Internal resistance
Lead wire

D-A80
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/IC circuit/PLC
AC 24V DC or less

48V AC DC 40mA None

50mA

1 or less (Including 3m lead wire)

Oilproof vinyl heavy insulation cable, 3.4, 0.2mm2, 2 cores (Brown, Blue), 0.5m

This category 3 type autoswitch can only be used in zones 2 and 22.

How to order

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

D-A

-588
Suffix for ATEX certified CAT.3

Internal Circuit ( ): If not applicable for IEC Standard


D-A73
LED Brown(Red) Reed switch Resistance Zener diode CD-P11
Blue(Black) OUT(+) Brown(Red) to OUT() Blue(Black)

Switch No.
73 80 With indicator lamp Without indicator lamp

Lead wire length


No number L Z 0.5m 3m 5m (Except A80 )

Electrical Entry
Contact protection box

Perpendicular In-line

CD-P12

D-A80
Reed switch Contact protection box CD-P11 CD-P12
OUT() Brown(Red) to OUT( ) Blue(Black)

Note) qIn the case operation load is an inductive load. wIn the case the wiring length to load is > 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.

40

ATEX Compliant Reed Switch/Tie-rod Mounting

D-A54/D-A67-588
Grommet
Specifications D-A5 (With indicator light)
Auto switch model number ATEX Category Application Load voltage Max. load current and range Contact protection circuit Internal voltage drop Indicator light

PLC: Programmable Logic Controllar

D-A54
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC 24V DC 5 to 50mA Built-in 2.4V ON: When red light emitting diode

D-A6 (Without indicator light)


Auto switch model number

D-A67
II 3GD EEx nA II T5 X -10CTa+60C IP67
PLC/IC circuit MAX. 24V DC 30mA None 1 (Including 3m lead wire)

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

ATEX Category Application Load voltage Max. load current Contact protection circuit Internal resistance
Lead wire

Oilproof vinyl heavy insulation cable, 4, 0.3mm2, 2 cores (Brown, Blue), 0.5m or 4, 0.2mm2, 3 cores (Brown, Black, Blue), 0.5m

This category 3 type autoswitch can only be used in zones 2 and 22.

How to order

D-A
Internal Circuit ( ): If not applicable for IEC Standard
D-A54
OUT() to Blue(Black)

-588
Suffix for ATEX certified CAT.3

Zener diode Choke coil LED Reed switch Resistance


Surge absorber
OUT(+) to Brown(Red)

Switch No.
54 67 With indicator lamp Without indicator lamp

Lead wire length


No number L Z 0.5m 3m 5m

41

ATEX Compliant Reed Switch/Direct Mounting

D-A90/D-A93-588
Grommet
Specifications D-A90 (Without indicator light)
Auto swich modle number ATEX Category Application Load voltage Max. load current Contact protection circuit Internal resistance 24V
AC DC

PLC: Programmable Logic Controller

D-A90
II 3GD EEx nA II T5 X -10CTa+60C IP67
IC circuit/Relay/PLC or less None 1 or less (Including 3m lead wire) 48V
AC DC

or less

50mA

40mA

D-A93 (With indicator light)


Auto switch model number ATEX Category Application Load voltage Max. load current and load current range Contact protection circuit Internal voltage drop Indicator light
Lead wire D-A90/D-A93

D-A93
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC 24V DC 5 to 40mA None 2.4V (up to 20mA)/ 3V (up to 40mA) ON: When red light emitting diode

Oilproof vinyl heavy insulation cable, 2.7, 0.18mm2 X 2cores (Brown, Blue)

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

This category 3 type autoswitch can only be used in zones 2 and 22.

Dimensions

D-A
Internal Circuit ( ): If not applicable for IEC Standard
Reed switch

-588
Suffix for ATEX certified CAT.3 Lead wire length
No number L Z 0.5m 3m 5m (Except D-A90 )

D-A90

Contact protective box CD-P11 CD-P12

OUT() Brown(Red) to OUT( ) Blue(Black)

Switch No.
93 90 With indicator lamp Without indicator lamp

D-A93
LED Reed switch Resistance Zener diode CD-P11 Blue(Black) CD-P12 Brown(Red) Contact protective box OUT(+) Brown(Red) to OUT() Blue(Black)

Electrical entry
No number V In line Perpendicular

Note) qIn the case operation load is an inductive load. wIn the case the wiring length to load is > 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.

42

ATEX Compliant Reed Switch/Direct Mounting

D-90A/D-93A-588
Grommet Lead wire: Heavy insulation cable
Specifications D-90A (Without indicator light)
Auto switch model number ATEX Category Application Load voltage Max. load current Internal resistance

PLC: Programmable Logic Controller

D-90A
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/IC circuit/PLC 24V AC DC 50mA 1 or less (Including 3m lead wire)

D-93A (With indicator light)


Auto switch model number ATEX Category Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type. Application Load voltage Load current range Internal voltage drop Indicator light
Lead wire

D-93A
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC 24V DC 5 to 40mA 2.4V ON: When red light emitting diode

Oilproof vinyl heavy insulation cable, 0.2mm2, 2 cores (Brown, Blue), 0.5m

This category 3 type autoswitch can only be used in zones 2 and 22.

Internal Circuit ( ): If not applicable for IEC Standard


D-90A

How to order
Reed switch Contact protection box CD-P11 CD-P12
OUT() Brown(Red) to OUT( ) Blue(Black)

D-

-588
Suffix for ATEX certified CAT.3

D-93A
Brown (Red) Reed switch Zener diode Resistance LED Blue (Black) Contact protection box CD-P11 CD-P12 OUT(+) Brown(Red) to OUT() Blue(Black)

Switch No.
93 90 With indicator lamp Without indicator lamp

Lead wire length


No number L Z 0.5m 3m 5m

Note) qIn the case operation load is an inductive load. wIn the case the wiring length to load is > 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.

43

ATEX Compliant Reed Switch/Direct Mounting

D-Z73/D-Z80-588
Grommet
Specifications D-Z7 (With indicator light)
Auto swich model number ATEX Category Application Load voltage Max. load current and load current range Contact protection circuit Internal voltage drop Indicator light

PLC: Programmable Logic Controller

D-Z73
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC 24V DC 5 to 40mA None 2.4V (up to 20mA)/ 3V (up to 30mA) ON: When red light emitting diode

D-Z8 (Without indicator light)


Auto switch model number ATEX Category

D-Z80
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC/IC circuit

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Application Load voltage Max. load current Contact protection circuit Internal resistance
Lead wire

24V AC or less DC
50mA None

48V AC or less DC
40mA

1 or less (Including 3m lead wire)

Oilproof vinyl heavy insulation cable, 3.4, 0.2mm2, 3 cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.5m

This category 3 type autoswitch can only be used in zones 2 and 22.

How to order

Internal Circuit ( ): If not applicable for IEC Standard


D-Z73
LED Brown(Red) Reed switch Resistance Zener diode CD-P11
Blue(Black)

D-Z

-588
Suffix for ATEX certified CAT.3

Contact protection box

OUT(+) Brown(Red) to OUT() Blue(Black)

CD-P12

Switch No.
73 80 With indicator lamp Without indicator lamp

Lead wire length


No number L Z 0.5m 3m 5m

D-Z80
Reed switch Contact protection box CD-P11 CD-P12
OUT() Brown(Red) to OUT( ) Blue(Black)

Note) qIn the case operation load is an inductive load. wIn the case the wiring length to > 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.

44

ATEX Compliant Reed Switch/Direct Mounting

D-E73A/D-E80A-588
Grommet
Specifications D-E73A (With indicator light)
Auto swich model number ATEX Category Application Load voltage Max. load current and load current range Contact protection circuit Internal voltage drop Indicator light

PLC: Programmable Logic Controller

D-E73A
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC 24V DC 5 to 40mA None 2.4V ON: When red light emitting diode

D-E80A (Without indicator light)


Auto switch model number ATEX Category Application Load voltage Max. load current

D-E80A
II 3GD EEx nA II T5 X -10CTa+60C IP67
Relay/PLC/IC circuit

24V AC or less DC
50mA None

48V AC DC
40mA

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Contact protection circuit Internal resistance


Lead wire

1 or less (Including 3m lead wire)

Oilproof vinyl heavy insulation cable, 3.4, 0.2mm2, 3 cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.5m

This category 3 type autoswitch can only be used in zones 2 and 22.

Internal Circuit ( ): If not applicable for IEC Standard


D-E73A
LED Reed switch Resistance Zener diode Brown(Red) Contact protection box CD-P11 Blue(Black) CD-P12 OUT(+) Brown(Red) to OUT() Blue(Black)

How to order

D-E

-588
Suffix for ATEX certified CAT.3

D-E80A
Reed switch Contact protection box CD-P11 CD-P12
OUT() Brown(Red) to OUT( ) Blue(Black)

Switch No.
73 80 With indicator lamp Without indicator lamp

Lead wire length


No number L Z 0.5m 3m 5m (Except D-E80A)

Note) qIn the case operation load is an inductive load. wIn the case the wiring length to load is > 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.

45

ATEX Compliant Solid State Switch/Band Mounting

D-H7A2-588
Grommet
ATEX Category Wiring Output Application Power voltage Current consumption Load voltage Load current Internal voltage drop

Specifications D-H7 (With indicator light)


Auto switch model number

PLC: Programmable Logic Controller

D-H7A2 II 3GD EEx nA II T5 X -10CTa+60C IP67


3 wire PNP IC circuit/Relay/PLC 5/12/24V DC (4.5 to 28 VDC) 10mA or less 80mA or less 0.8V or less 100A or less at 24 VDC Red LED lights up

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Current leakage Indicator light


Lead wire

Oilproof heavy-duty vinyl cord, 3.4, 0.2mm2, 3 cores (Brown, Black, Blue)

This category 3 type autoswitch can only be used in zones 2 and 22.

How to order

D-H7A2
Internal Circuit
D-H7A2
DC(+) Brown Main Circuit of switch

-588
Suffix for ATEX certified CAT.3

Switch No.

Lead wire length


No number L Z 0.5m 3m 5m

OUT Black

DC() Blue

46

ATEX Compliant Solid State Switch/Rail Mounting

D-F7P(V)-588
Grommet
Auto switch model number ATEX Category Electrical entry Wiring Output Application Power voltage Current consumption Load voltage Load current Internal voltage drop Current leakage Indicator light
Lead wire

Specifications D-F7P, D-F7PV (With indicator light)

PLC: Programmable Logic Controller

D-F7PV D-F7P II 3GD EEx nA II T5 X -10CTa+60C IP67


3 wire PNP IC circuit/Relay/PLC 5/12/24V DC (4.5 to 28VDC) 10mA or less 80mA or less 0.8V or less 100A or less at 24VDC Red LED lights up

Oilproof heavy-duty vinily cord, 3.4, 0.2mm2, 3 cores (Brown, Black, Blue)

This category 3 type autoswitch can only be used in zones 2 and 22.

How to order
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

D-F7P
Switch No.

-588
Suffix for ATEX certified CAT.3 Lead wire length
No number L Z 0.5m 3m 5m

Internal Circuit
D-F7P, D-F7PV
DC(+) Brown Switch main circuit

Electrical entry
No number V Right arm Perpendicular

OUT Black DC() Blue

47

ATEX Compliant Solid State Switch/Tie-rod Mounting

D-F5P-588
Grommet
Wiring Output Application Power voltage

Specifications D-F5P (With indicator light)


Auto switch model number ATEX Category

PLC: Programmable Logic Controller

D-F5P
II 3GD EEx nA II T5 X -10CTa+60C IP67
3 wire PNP IC circuit/Relay/PLC 5/12/24V DC (4.5 to 28VDC) 10mA or less 80mA or less 0.8V or less 100A at 24VDC Red LED lights up

Current consumption Load voltage Load current Internal voltage drop

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Current leakage Indicator light


Lead wire

Oilproof heavy-duty vinyl cord, 4, 0.3mm2, 3 cores (Brown, Black, Blue)

This category 3 type autoswitch can only be used in zones 2 and 22.

How to order

Internal Circuit
D-F5P
DC(+) Brown Main circuit of switch

D-F5P

-588
Suffix for ATEX certified CAT.3

OUT Black DC() Blue

Switch No.

Lead wire length


No number L Z 0.5m 3m 5m

48

ATEX Compliant Solid State Switch/Direct Mounting

D-Y7P(V)-588
Specifications

PLC: Programmable Logic Controller

Grommet

D-Y7P/D-Y7PV (With indicator light)


Auto switch model number ATEX Category Electrical entry Wiring Output Application Power voltage Current consumption Load voltage Load current Internal voltage drop Current leakage 80mA or less 0.8V or less 100A or less at 24VDC Red LED lights up

D-Y7P D-Y7PV II 3GD EEx nA II T5 X -10CTa+60C IP67


In-line
3 wire PNP IC circuit/Relay/PLC 5/12/24V DC (4.5 to 28VDC) 10mA or less

Perpendicular

Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.

Indicator light
Lead wire

Oilproof heavy-duty vinyl cord, 3.4, 0.15mm2, 3 cores (Brown, Black, Blue)

This category 3 type autoswitch can only be used in zones 2 and 22.

How to order

D-Y7P
Internal Circuit
D-Y7P, D-Y7PV
DC(+) Brown Main circuit of switch

-588
Suffix for ATEX certified CAT.3 Lead wire length
No number L Z 0.5m 3m 5m

Switch No.

Electrical entry
No number V Right arm Perpendicular

OUT Black DC() Blue

49

Pneumatic-Pneumatic Positioner

Series Series

55/56-IP5000 55/56-IP5100
How to Order

(Lever type) (Rotary type)


For more details, other specifications, dimensions, see the specific catalogue.

II 2GDc T4-T6 II 3GDc T4-T6

56 - IP5 000
ATEX category
55 56 2 3

0 1 0
Accessories Note 1)
Nil A B C D E F Without accesory With standard lever (10 to (standard) 85 mm stroke) for 55/56-IP5000 With 0.7 output restrictor Common to 55/56-IP5000 integrated pilot valve and 55/56-IP5100 small With 1.0 output restrictor capacity actuators integrated pilot valve With fork lever type fitting M Only for 55/56-IP5100 With fork lever type fitting S With lever unit for a 35 to 100 mm stroke Only for 55/56-IP5000 Note 2) With lever unit for a 50 to 140 mm stroke

Positioner type
000 100 Lever type Rotary type

Input pressure
0 1 Standard 0.02 to 0.1MPa 1/2 split, 0.02 to 0.06, 0.06 to 0.1MPa

Pressure gauge (SUP, OUT1)


0 1 2 3 Not provided 0.2MPa 0.3MPa 1.0MPa

Indication of opening Note 1)


0 1 Not indicated Indicated

Note 1) If multiple accessories are required, they should be indicated in alphabetical order. Note 2) For ''E'' and ''F'', standard lever is not provided.

Note 1) 55/56-IP5000 is available only with option ''0'' (no indication).

Pressure gauge / Air port


Nil N F Standard Rc NPT G

Ambient temperature
Nil Standard 20 to 80oC; T5 T High temperature 5 to 100oC; T4 L Low temperature 30 to 60oC; T6

Specifications
Classification II 2GD c T4 II 2GD c T5 II 2GD c T6 -30C Ta 60C

Note ) Please refer to page 3.

Ambient temperature range Low temp. model High temp. model Standard model 55-IP500-L- 55-IP500-- 55-IP500-T- -5C Ta 100C -20C Ta 80C -20C Ta 60C -5C Ta 80C -5C Ta 60C

Ambient temperature range Low temp. model High temp. model Standard model Classification 56-IP500-L- 56-IP500-- 56-IP500-T- II 3GD c T4 II 3GD c T5 II 3GD c T6 -30C Ta 60C -20C Ta 80C -20C Ta 60C -5C Ta 100C -5C Ta 80C -5C Ta 60C

Rotary type cam feedback Lever type lever feedback Item Double action Single action Double action Single action 0.14~0.7MPa Supply pressure Input pressure 0.02~0.1MPa Standard stroke 60~100 10~85mm Sensitivity Within 0.1%F.S. Within 0.5%F.S. Linearity Within 1%F.S. Within 2%F.S. Hysteresis Within 0.75%F.S. Within 1%F.S. Repeatability Within 0.5%F.S. Output flow rate 80l/min (ANR) or more (SUP.=0.14MPa) 200l/min (ANR) or more (SUP.=0.4MPa) Within 5l/min (ANR) or more (SUP.=0.14MPa) Air consumption Within 11l/min (ANR) or more (SUP.=0.4MPa) Ambient and using fluid -20C~80C (Standard model) -30C~60C (Low Temp.) -5C~100C (High Temp.) Temperature Within 0.1%F.S./C Thermal coefficient Rc1/4 (Standard) Air connection port Aluminium diecast, Stainless steel, Brass, Nitrile rubber Material Approx. 1.2kg Approx. 1.4kg Mass 118 x 92 x 77.5 (Body) 118 x 102 x 86 (Body) Size
Note) Standard air temperature: 20, Absolute pressure: 101.3KPa. Relative humidity: 65%

Type

55/56-IP5000

55/56-IP5100

50

Electro-Pneumatic Positioner

Series Series

IP6000 (Lever type) IP6100 (Rotary type)


How to Order

II 2G EEx ib IIC T5/T6

For more details, other specifications, dimensions, see the specific catalogue.

IP6 000

0 1 0

X14
ATEX category 2 Accessories Note 1)
Nil A B Without accesory With standard lever (10 to 85 mm stroke) for IP6000 (standard) With 0.7 output restrictor Common to IP6000 integrated pilot valve and IP6100 small With 1.0 output restrictor capacity actuators integrated pilot valve With fork lever type fitting MX Only for IP6100 With fork lever type fitting SX With lever unit for a 35 to 100 mm stroke Only for IP6000 With lever unit for a 50 to 140 mm stroke With compensation Common to IP6000 spring (A) and IP6100

Positioner type
000 100 Lever type Rotary type

Pressure gauge (SUP, OUT1)


1 2 3 0.2MPa (R1/8) 0.3MPa (R1/8) 1.0MPa (R1/8)

C D E F G

Specifications
Type Item Input current Input resistance Supply air pressure Standard stroke IP6000 IP6100 Rotary type cam Levery type lever Double action Single action Double action Single action 4~20mADC (Standard) Note1 235 15 (4~20mADC) 0.14~0.7Mpa 10~85mm (External lever allowable 60~100 Note2 runout angle 10~30

Note 1) If multiple accessories are required, they should be indicated in alphabetical order.

Sensitivity Within 0.5%F.S. Within 0.1%F.S. Linearity Within 2%F.S. Within 1%F.S. Within 1%F.S. Within 0.75%F.S. Hysteresis Repeatability Within 0.5%F.S. Within 0.1%F.S./C Thermal coefficient 80l/min (ANR) or more (SUP.=0.14MPa) Note3 Output flow rate Within 5l/min (ANR) (SUP.=0.4MPa) Air consumption -20C~80C (T5) Ambient and using fluid -20C~60C (T6) Temperature Explosion protected Intrinsic safety type of explosion protection Construction ( II 2G Eexib II CT5/T6) 0344 Air connection port Electric wiring connection port Material Mass Classification of degree of protection Parameters (Current circuit) Approval No. KEMA No.03 ATEX1119 1/4NPT female screw M20 x 1.5 Aluminium diecast for the body Approx. 2.4kg JISF8007 IP55 (Conform to IEC pub.529) Ui 28V, Ii 125mA, Pi 1.2W, Ci OnF, Li OmH

Note 1) 1/2 split range is possible with the standard type (by adjusting the span). Note 2) The stroke is adjustable in 0~60 and 0~100. Note 3) Standard air (JIS B0120): temp. 20C, absolute press. 760mmHg, ratio humidity 65%.

51

Series IP6000
Dimensions / IP6000

/ 6100

IP6000-00--X14 (lever type)


(OUT2.1/4NPT) Pluged
OUT2
SMC MPa {bar}

40 35

110

M A

SMC MPa {bar}

SPAN

65

Zero adjusting knob Span adjusting knob Two gauge ports are Rc1/8 thread 38 11 OUT1.1/4NPT SUP.1/4NPT 15 15
OUT2

22.5 4xM8x1.25 depth12 Female thread for mounting, backside.


MODEL NO. IP6*00-0*0-*-X14-* SUPPLY 0.14 to 0.7MPa(1.4 to 7bar)

VIEW OF A 2xM8x1.25 depth12 Female thread for mounting, side position

168 B

SMC ELECTRO-PNEUMATIC POSITIONER


Serial No.*****

20** MADE IN JAPAN INPUT 0/4 to 20mADC UI28V II125mA P1.2V CI0nf LI0nH EExIb CT6 Ta60C EExIb CT5 Ta80C SMC Corporation KEMA No.03ATEX1119 1-16-4 Shinbashi Minatoku Tokyo 105-8659 Japan

35

35

130 100

122

20

SMC MPa {bar}

6.1 16

42

SMC MPa {bar}

VIEW OF B

MODEL IP6000

125

At accessory E: 110 At accessory F: 110

} }

At accessory "E":195 150 At accessory "F":275

53

M20X1.5 Porting for electrical connection

125 =180

50

Mark ''M'' means that this port is ''M'' thread

NP

52

14

30

110

46

Electro-Pneumatic Positioner (ATEX directive category 2)

Series IP6000

/ 6100

Dimensions / IP6100

IP6100-00--X14 (rotary type)


Positioner body Hold spring 7 C C 24 View of CC side Lever and pin assembly Fork and shaft assembly Screw thread size M6x1 Main shaft of actuator Dimension of optional ''Fork lever assembly'' ( ) Shows dimension of fork lever assembly type ''SX''
E
SMC MPa {bar}

(OUT2.1/4NPT) Pluged
OUT2 M A

40 35

110

70(46) 63(39)

65

E
SPAN

Zero adjusting knob


SMC ELECTRO-PNEUMATIC POSITIONER
Serial No.*****

OUT1.1/4NPT 38 11 SUP.1/4NPT
20** MADE IN JAPAN INPUT 0/4 to 20mADC UI28V II125mA P1.2V CI0nf LI0nH EExIb CT6 Ta60C EExIb CT5 Ta80C SMC Corporation KEMA No.03ATEX1119 1-16-4 Shinbashi Minatoku Tokyo 105-8659 Japan MODEL NO. IP6*00-0*0-*-X14-* SUPPLY 0.14 to 0.7MPa(1.4 to 7bar)

15 15
SMC MPa {bar}

Two gauge ports are Rc1/8 thread 168 B


OUT2

VIEW OF A 4xM8x1.25 depth12 Female thread for mounting, backside.

35

130 100

35

122

20

42

VIEW OF B

22.5
90o

21

50

SMC MPa {bar}

DA
E P

SMC MPa {bar}

60o 30o

MODEL IP6100

Oo
30o

53

NP

44

116

60o

90o

M20x1.5 Porting for electrical connection Mark ''M'' means that this port is ''M'' thread

125 =180

46 2xM8x1.25 depth12 Female thread for mounting, side position

53

Electro-Pneumatic Positioner

Series Series
IP8 000
Positioner type
000 100 Lever type Rotary type

IP8000 (Lever type) IP8100 (Rotary type)


How to Order

II 2G EEx ib IIC T5/T6

For more details, other specifications, dimensions, see the specific catalogue.

0 0 0

X14

L
Ambient temperature
Nil Standar: 20 to 80C L Low temperature: 40 to 60C

ATEX category 2 Accessories Note 1)


Nil A B Without accesory (standard) With 0.7 output restrictor integrated pilot valve With 1.0 output restrictor integrated pilot valve With fork lever type fitting MX With fork lever type fitting SX With lever unit for a 35 to 100 mm stroke With lever unit for a 50 to 140 mm stroke With compensation spring (A) With external scale plate

With standard lever (10 to 85 mm stroke) for IP8000 Common to IP8000 and IP8100 small capacity actuators Only for IP8100

Pressure gauge (SUP, OUT1)


0 1 2 3 Not provided 0.2MPa (R1/8) 0.3MPa (R1/8) 1.0MPa (R1/8)

C D E F G H

Only for IP8000 Common to IP8000 and IP8100 Only for IP8100

Note 1) If multiple accessories are required, they should be indicated in alphabetical order.

Specifications
Type Item Input current Input resistance Supply air pressure Standard stroke Sensitivity Linearity Hysteresis Repeatability Coefficient of temperature Output flow rate Air consumption Ambient and using fluid temperature Explosion protected construction Air connection port Electrical wiring connection Material Weight Classification of degree of protection Parameters IP8000
Lever type lever feedback

IP8100
Rotary type cam feedback

Single action Double action Single action Double action 4 to 20mADC (standard) Note 1) 23515 (4 to 20mADC) 0.14 to 0.7MPa 10 to 85mm (Deflection angle 10 to 30) Within 0.1%F.S. Within 1%F.S. Within 0.75%F.S. 60 to 100 Note 2) Within 0.5%F.S. Within 2%F.S. Within 1%F.S. Within 0.5%F.S. Within 0.1%F.S. / C 80l/min (ANR) or more (SUP = 0.14MPa) Note 3) Within 5l/min (ANR) or less (SUP = 0.14MPa) Standard type: 20 to 80C (T5) / 20 to 60C (T6) Low temperature type: 40 to 60C (T6) Intrinsic safety type of explosion protection ( 0344 2G EEx ib c T5/T6) Approval no. KEMA 03 ATEX1119 1/4 NPT female screw M20x1.5 Aluminum diecast body Approx. 2.4kg JISF8007, IP65 (conforms to IEC Pub.529) Ui 28 V, li 125 mA, Pi 1.2W, Ci 0nF, Li 0mH

Note 1) 1/2 Split range is possible with the standard type (by adjusting the span). Note 2) The stroke is adjustable in 0 to 60C and 0 to 100 Note 3) Standard air (JIS B0120): temp. 20C, absolute press. 760mmHg, ratio humidity 65%.

54

Series IP8000
Accessory / Option

/ 8100
External feedback lever (IP8000 type)
Different feedback levers are available dependent upon valve strokes. Consult with SMC in case of 10mm or less stroke. Stroke 10 to 85mm (Accessory Nil) 35 to 100mm (Accessory E) 50 to 140mm (Accessory F) Unit number P368010-20 P368010-21 P368010-22 Size M Size N 125 110 110 150 195 275

Pilot valve with output restriction (IP8000, 8100 type)


In general, mounting on a small-size actuator may cause hunting. For prevention, a pilot valve with a built-in output restriction is available. The restriction is removable. (Ambient temperature: Standard) Actuator Capacity Orifice size Part number 90cm3 180cm3 0.7 1 P36801080 P36801081 Pilot unit part number P565010-18 P565010-19

Fork lever joints (IP8100 type)


Two types of the fork lever joints are available dependent upon different mounting dimensions. This is recommended because it can absorb off-centering, compared with direct mounting type. Part name Fork lever assembly MX Fork lever assembly SX Part number P368010-36 P368010-37
L2=31 (MX type: 55) 39 (MX type: 63) 6.1 16

M N

Cable gland (for -X14)


Cable gland
Description Cable gland Part number 07-9534-1M2B
Suited cable outer diameter

63 (SX type: 39) L1=101 (SX type: 77)

M6 x 1 Actuator main shaft

6 to 12

M6 x 1

Actuator main shaft

Side mounting with the fork lever assembly MX

Side mounting with the fork lever assembly SX

M20 x 1.5

Exploded View
Body cover unit (3) Cover seal
E L E C T O R O

P N E U M A T IC

IP 8 0 0 0

(1) Pilot valve unit


M
A

Compensation spring Zero adjusting unit

Feedback spring Mini-terminal unit (No terminal box) Span adjusting unit
SP AN

Torque motor unit Feedback shaft assembly

Terminal joint unit (No terminal box)


SM

C
Pa M

Feedback lever unit


Pa M

C SM
OU

SU P

Body unit

Replacement Parts (Ambient temperature: Standard)


No. 1
(2) Base seal

Description Pilot valve unit Base seal Cover seal

Part no. P565010-7 P56501012-3 P56501013

Note IP8000/8100

2 3

55

Electro-Pneumatic Positioner (ATEX directive category 2)

Series IP8000

/ 8100

Dimensions / IP8000

IP8000-00--X14 (lever type)


40 35 192 110 58

2xM8x1.25 depth12 Female thread for mounting, backside

23.5
OUT2

(OUT2.1/4NPT) Pluged
SMC MPa {bar}
M A

2xM8x1.25 depth12 Female thread for mounting, side position

SMC MPa {bar}

122 65

22.5

SPAN

Zero adjusting knob VIEW OF A OUT1.1/4NPT 38 11 SUP.1/4NPT 9 2 x Rc1/8 23.5 43 B


OUT2

Span adjusting knob

198
20** MADE IN JAPAN INPUT 0/4 to 20mADC UI28V II125mA P1.2V CI0nF LI0nH EExIb CT6 Ta60C EExIb CT5 Ta80C SMC Corporation KEMA No.03ATEX1119 1-16-4 Shinbashi Minatoku Tokyo 105-8659 Japan MODEL NO. IP8*00-0*0-*-X14-* SUPPLY 0.14 to 0.7MPa(1.4 to 7bar)

SMC ELECTRO-PNEUMATIC POSITIONER


Serial No.*****

39

39

SMC MPa {bar}

VIEW OF B 42

147 117

A
1

ELECTORO PNEUMATIC IP8000

50

20

SMC MPa {bar}

110 { At accessory E: 110 } At accessory F:

6.1 16 125

35

NP

56

14

2 30 46

100

M20 x 1.5 Porting for electrical connection Mark ''M'' means that this port is ''M'' thread

125 =199

{ At accessory "E":195 } At accessory "F":275

150

Series IP8000
Dimensions / IP8100

/ 8100

IP8100-00--X14 (rotary type)


(OUT2.1/4NPT) Pluged
OUT2

SMC MPa {bar}

SMC MPa {bar}

20** MADE IN JAPAN INPUT 0/4 to 20mADC UI28V II125mA P1.2V CI0nf LI0nH EExIb CT6 Ta60C EExIb CT5 Ta80C SMC Corporation KEMA No.03ATEX1119 1-16-4 Shinbashi Minatoku Tokyo 105-8659 Japan

MODEL NO. IP6*00-0*0-*-X14-* SUPPLY 0.14 to 0.7MPa(1.4 to 7bar)

SMC ELECTRO-PNEUMATIC POSITIONER


Serial No.*****

E
SPAN

VIEW OF B

Zero adjusting knob OUT1.1/4NPT SUP.1/4NPT 38 11 9


OUT2

2 x Rc1/8 23.5 43

198 B 4xM8x1.25 depth12 Female thread for mounting, side position 42

40 35

192 110

58

23.5

39

147 117

39

SMC MPa {bar}

22.5 2xM8x1.25 depth12 Female thread for mounting, backside.

ELECTORO PNEUMATIC IP8100


1

35

M20 x 1.5 Porting for electrical connection Mark ''M'' means that this Hold spring port is ''M'' thread

125 =199 Mark ''M'' means that this port is ''M'' thread

50

122 65

20

SMC MPa {bar}

Positioner body

VIEW OF A

70(46) 63(39)

24

View of CC side Lever and pin assembly Fork and shaft assembly Screw thread size M6x1 Main shaft of actuator

NP

Dimension of optional ''Fork lever assembly'' ( ) Shows dimension of fork lever assembly type ''SX''

21

15

44 46

100

57

Smart Positioner (Rotary Type)

Series

IP8101

II 1G EEx ia IIC T4

For more details, other specifications, dimensions, see the specific catalogue.

Dual wire input - compatible with conventional facilities


Controllable by a conventional dual wire input signal (4 to 20 mA DC) which does not require a different power supply.

Calibration function integrated


Easier to perform zero/span adjustment than a conventional mechanical positioner.

Integrated parameter function


Numerous parameter setting functions are available. Parameter Settings List
Function Parameter Normal/reverse run setting Split range setting Zero/span adjustment setting Forced fully-closed/fully-open setting Dead band setting Standard functions Valve characteristic settings Linearity chracteristics Equal % characteristics (class 2) Quick open characteristics (class 2) Users point setting PID constant setting Calibration setting Alarm 1 output setting Optional functions Alarm 2 output setting Analog output (4 to 20 mA DC) setting

Output functions
The alarm point output function (2 points) and a continuous analog output (4 to 20 mA DC) function are available.

HART transmission mode


HART transmission mode is available.

ATEX compliant
ATEX intrinsically safe explosion protection type construction is available.

Displayable control condition


The positioning, deviation, input value are displayed on a LCD inside the body cover.

Interchangeable mountings
The dimensions for mounting the main body and the fork lever type fittings are identical to the conventional mechanical type, IP8100 electro-pneumatic positioner.

How to Order
Specifications
4
With intrinsically safe explosion protection construction + Output + HART transmission mode

Electrical connection port Note 2)


M
M20 x 1.5
Note 2) Please contact us if the NPT or G thread is required.

52 IP8101 03 4
ATEX compliant
52
ATEX directive category 1 compliant

M Q
Accessory Note 1)
Symbol

IP8101 03 0
Type
Rotary smart type

101

Pressure gauge
3
1.0 MPa

Specifications
0 2 3
Basic With output (Alarm output x 2 + Analog output (4 to 20 mA DC)) With HART transmission mode

C D H

Description None Fork lever type fitting M Fork lever type fitting S With external scale

Note 1) If two or more accessories are required, the part numbers should be ordered according to alphabetical order. Example: IP8101-030-CH

58

Series IP8101
Specifications
Model Description Input current Voltage between terminals Supply air pressure Applicable actuator rotation angle Air consumption Linearity Note 2) Hysteresis Note 2) Sensitivity Note 2) Enclosure Note 3) Outer sheath protection class Operating temperature range Transmission mode Note 3)

IP8101
Smart positioner (Rotary type) 4 to 20 mA DC 12 V DC (Input resistance equivalent to 600 , at 20 mA DC) 0.3 to 0.7 MPa 60 to 100 11 l/min (ANR) or less (SUP: at 0.4 MPa) Within 1% F.S. Within 0.5% F.S. Within 0.2% F.S. ATEX intrinsically safe explosion protection construction 1G EExia CT4 Ta80C 1D T63C Ta60C JISF8007 IP65 (Conforming to IEC Pub.529) 20 to 80C 20 to 60C (at ATEX/ 1D) HART

Note 1) Values in the specifications are at room temperature (20C). Note 2) Properties related to the precision may differ depending on the combination between a positioner and the loop components such as an actuator. Note 3) It is required to select the model numbers for the intrinsically safe product with explosion protection type construction and the HART transmission mode.

Dimensions

44

View A
192 40 35 110 58 23.5 23.5
SMC

231 198 43 11 38
OUT2

15

46

121

OUT1. Rc1/4 SUP. Rc1/4

42

MPa

39

39

SMC

147

65

20

MPa

25%

122

50

22.5

electro-pneumatic

4 x M8 depth 12 Female thread for bottom mounting 2 x M8 depth 12 Female thread for side mounting

125 229 262 Resin cable gland Applicable cable O.D. 6 to 12 (attached only to the intrinsically safe explosion protection type construction)

23

28

2 x G1/2 (Standard), Electrical connection Note) 2 x M20 x 1.5 (Intrinsically safe explosion protection type construction)

When the external scale is attached. (Accessory: H)


Note) When either 0 or 3 is chosen in the model number, the number of the electrical connection ports will be one.

OUT2. Rc1/4

110

38

59

14

10

0%

75%

50%

DA

109

0%

Process Pump. Automatically operated type Air operated type

Series

Automatically operated type (internal switching type) Air operated type (external switching type)
II 3 GD c T6 Ta 0C to 60C

56-PA3000/5000
How to Order

For more details, other specifications, dimensions, see the specific catalogue.

Automatically operated type (internal switching type)


PA3000

56
PA5000 ATEX category 3
3 5

PA 3 1 1 0
Body size
3/8 standard 1/2 standard

03
Option
Nil N
Body only With silencer
For AIR EXH: AN200-02

Liquid contact body material


1 2
ADC12 (Aluminum) SCS14 (stainless steel)

Connection port size


03 04 06
3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5

Diaphragm material
Symbol
AIR SUP FLUID OUT

1 2

PTFE NBR

Thread type
Nil T F N
Rc NPTF G NPT

Made to Order
X43
Standard No resin cover and no mounting foot: PA3

AIR EXH

FLUID IN

T, F, N are order made Note) Contact SMC for specifications and dimensions. specifications.

Automatically operated type


Automatically operated type

Air operated type (external switching type)


PA3000

56
PA5000 ATEX category 3
3 5

PA 3 1 1 3
Body size
3/8 standard 1/2 standard

03
Connection port size
03 04 06
3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5

Liquid contact body material


1 2
ADC12 (Aluminum) SCS14 (stainless steel)

Thread type
Nil T F N
Rc NPTF G NPT

Symbol

Diaphragm material
P1 P2 FLUID OUT

PTFE

T, F, N are order made specifications.

Air operated type


FLUID IN

Made to Order
X43
Standard No resin cover and no mounting foot: PA3

Air operated type

Note) Contact SMC for specifications and dimensions.

60

Booster Regulator

Series 56-VBA1100 to 4200


II 3 GD c T6 Ta 2C to 50C
For more details, other specifications, dimensions, see the specific catalogue.

How to Order

VBA1000

56
ATEX category 3

VBA 1 1 1 0
Body size
1 1/4

02 GN
Option
G Pressure Gauge (MPa) Silencer N The option is delivered in the same packing but it is not mounted.

Pressure setting
1 Handle operated

Port size
Symbol 02 Port size 1/4

VBA1110-02 VBA1111-02

Pressure class
1 2.0MPa

Thread type Pressure increase ratio


0 1 2 times 4 times

Nil T F N

Rc NPTF G NPT

VBA2000/4000

56 VBA 2 1 0 0
ATEX category 3 Body size
2 4 3/8 1/2

03 GN
Option
Gauge G Silencer N The option is delivered in the same packing but it is not mounted.

Pressure setting
1 2 VBA4100-04 Handle operated style VBA2100-03 Handle operated Air operated

Pressure class
0 1.0MPa

Port size
Symbol

03 04

Port size 3/8 1/2

Applicable series VBA2100, 2200 VBA4100, 4200

Pressure increase ratio


0 2 times

Thread type
Nil T F N
Rc NPTF G NPT

Special request
VBA4200-04 Air operated style

X16
VBA2200-03

Standard Sepecial request for VBA400

61

5 Port Solenoid Valve

Series
52 - SY 5 1 2 0
ATEX category 2 Series
5 7 9 52-SY5000 52-SY7000 52-SY9000

52-SY
II 2G EEx ia IIB T4...T6

For more details, other specifications, dimensions, see the specific catalogue

How to Order

L 3

01 F
Bracket
Nil No bracket F1 With foot bracket* F2 With side bracket** *Foot bracket only available for 2 position single solenoid valve 52-SY5000 and 52-SY7000. **Side bracket only for 52-SY5000 and 52-SY7000. ***No bracket for only body ported type's 52-SY9000.

Type of actuation
1 2 3 4 5 2-position single 2-position double 3-position closed centre 3-position exhaust centre 3-position pressure centre

Thread style
Nil F N T Rc G NPT NPTF

Piping style
2 4 Body ported type Base mounted type Sign 01 C4 C6 C8 N3 N7 N9 02 C8 C10 N9 N11 02 03 C8 C10 C12 N9 N11 Sign 02 02 03 03 04

Type of actuation Pilot


Port size 1/8 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting 5/32" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 1/4 8 One-touch fitting 10 One-touch fitting 5/16" One-touch fitting 3/8" One-touch fitting 1/4 3/8 8 One-touch fitting 10 One-touch fitting 12 One-touch fitting 5/16" One-touch fitting 3/8" One-touch fitting Compatible series

Internal pilot Nil External pilot* R *Only the base mounted type.

52-SY5000

Barrier
Nil A B C D E Without barrier Z728.H MTL728P+ MTL7128P+ MTL5021 KFD2-SD-Ex1.17

52-SY7000

One per solenoid supplied.

52-SY9000

Electrical entry
Plug connector type L LL Plug connector with cover type Terminal type TT

Lead wire length


300 mm 3 600 mm 6 1000 mm 10 1500 mm 15 2000 mm 20 3000 mm 30 100 10000 mm (semi-standard) L type has 300mm and 600mm only.

Port size (Base mounted type) Port size Compatible series No sub-plate 52-SY5000 1/4 1/4 52-SY7000 3/8 3/8 52-SY9000 1/2

Manual override
Non locking push style Nil D Push-turn locking slotted style E Push-turn locking lever style

62

5 Port Solenoid Valve

Series 52-SY
For more details, other specifications, dimensions, see the specific catalogue

Specifications
Series Ambient and fluid Temperature class T6 Temperature class T4, T5 temperature Coil temperature rise Barrier input voltage (non hazardous area) Solenoid valve input voltage (hazardous area) Intrinsically safe Gas group L type plug connector Electrical entry T type terminal box 52-SY5000 52-SY7000 52-SY9000
45C 50C 40C or less (at rated) 24VDC (system rated voltage) at 1.1W 12VDC at 0.52W ia IIB IP30 (LL type : IP40) IP65

Safety Instructions
1) This product is not suitable for Zone 0. The suitable zones are Zones 1 and 2. 2) SMC-TAS and TAU Series, antistatic tubing, is available if required. 3) the solenoid valve has polarity (+ -). Confirm the correct polarity by referring to the colour of the lead wires. If the polarity is reversed, the barrier maybe damaged. 4) Confirm that the solenoid input voltage at the lead wires is DC 10.8V (min). 5) The product must be connected to a certified barrier or certified intrinsically safe circuit with the follow maximum Values: Ui= 28V li= 225mA (resistively limited) Pi= 1W Ci= 0.nF Li= 0 nH Note) The valve is not supplied with barrier.

Note1) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test were performed one time each in the axial and right angle directions of the main valve and armature, in both energised and de-energised states (Valve in the initial stage). Vibration resistance: No malfunction ocurred in a one-sweep test between 8.3 and 2000Hz. The test was performed for both energised and de-energised states in the axial and right angle directions of the main valve and armature (valve in the initial stage).

Response time
Configuration 2-position single 2-position double 3-position Response time (ms) (0.5MPa) 52-SY5000 52-SY7000 52-SY9000 26 or less 38 or less 50 or less 22 or less 30 or less 50 or less 38 or less 56 or less 70 or less

Note1) According to dynamic performance test JIS B8375-1981. Note2) Response time when barriers were combined with a valve. System A: Valve + Z728.H (Pepperl + Fuchs) B: Valve + MTL728P+ C: Valve + MTL7128P+ E: Valve + KFD2-SD-Ex1.17 (Pepperl + Fuchs) Note3) When system D is used, the ON time is delayed 17ms more than response time in table. System D: Valve + MTL5021

Manifold specifications for 20 type


Model Applicable valve Manifold style 1 (SUP)/ 3/5 (EXH) Valve stations 4/2 (A/B) Location 1,3,5 (P,EA,EB) Port Port size 4,2 (A,B) Port SS5Y5-20 52-SY5*20 SS5Y7-20 52-SY7*20

Manifold specifications for 20 type


Model SS5Y5-20 SS5Y7-20 Flow characteristics Port size 1 > 4/2 (P>A/B) 4/2 > 5/3 (A/B > EA/EB) 4,2 1,5,3 b Cv Cv c[dm3/(s.bar)] (P,EA,EB) (A,B) c[dm3/(s.bar)] b 1/4 1/4 C8 C10 1.90 3.60 0.28 0.93 0.48 3.60 2.20 0.93 0.20 0.27 0.53 0.88

Single base/ B mounting Common SUP/ Common EXH 2 to 20 (1) Valve 1/4

Note) Values for 5 stations manifold with a 2 position single type valve.

1/8 1/4 C4 (One-touch fittings for 4mm) C8 (One-touch fittings for 8mm) C6 (One-touch fittings for 6mm) C10 (One-touch fittings for 10mm) C8 (One-touch fittings for 8mm) W=36n+64 Manifold base weight W (g) n: Station W=43n+64
Note1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port on both sides and exhaust from EA/EB port on both side. Note2) 52-SY9*20 valve are not available with manifold as standard. Please contact SMC if you require it: Note3) 52-SY series are not available with resin type manifold (23 type, 20P type and 45 type).

Manifold specifications for 41 and 42 type


Model Applicable valve Manifold style 1 (SUP)/ 3/5 (EXH) Valve stations Location 4/2 (A/B) Porting spec. Direction 1,3,5 (P,EA,EB) Port Port size 4,2 (A,B) Port Manifold base weight W (g) n: Station SS5Y5-41 SS5Y5-42 52-SY5*40
Single base/ B mounting Common SUP/ Common EXH 2 to 20 (1) Base Side 1/4 1/4
1/8 1/4 1/4 C6 (One-touch fittings for 6mm) C6 (One-touch fittings for 6mm) C10 (One-touch fittings C8 (One-touch fittings for 8mm) C8 (One-touch fittings for 8mm) for 10mm)

Manifold specifications for 41 and 42 type


SS5Y7-42 52-SY7*40 Model SS5Y5-41 SS5Y5-42 SS5Y7-42 Flow characteristics Port size 1 > 4/2 (P>A/B) 4/2 > 5/3 (A/B > EA/EB) 4,2 1,5,3 b Cv Cv c[dm3/(s.bar)] (P,EA,EB) (A,B) c[dm3/(s.bar)] b 1/4 1/4 1/4 C8 C8 C10 1.80 1.90 3.00 0.23 0.20 0.25 0.44 0.46 0.75 1.90 1.90 3.00 0.16 0.12 0.12 0.45 0.43 0.66

Note) Values for 5 stations manifold with a 2 position single type valve.

W=61n+101

W=79n+127

W=100n+151

Note1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port on both sides and exhaust from EA/EB port on both side. Note2) 52-SY9*40 valve are not available with manifold as standard. Please contact SMC if you require it: Note3) 52-SY series are not available with resin type manifold (23 type, 20P type and 45 type).

63

Series 52-SY
Dimensions

Body ported type Dimensions/ Series 52-SY5000 2-position single Plug connector type (L) 52-SY5120-L-01(-F2)

22.6

21 16.7

In case with foot bracket 52-SY5120-L-01-F1


47 38 4.5

16.6

22 111.8

65 Insulation Black(-) A Insulation Red(+) Manual override 16.2 36 2-3.2 (Mounting holes) 44 (For E type) (37)

2-M3 Threads depth 3.5 (For bracket mounting) 14.7 11.6 40 B 2-3.2 (Mounting holes for manifold) 2-1/8" {4(A),2(B) Port} 2-3.2 (Mounting holes)

14.7

(1.2) (11.7) L (Lead wire length) 109.1

1.55

(32.3) 32.3 1.6

0.8

3-1/8" {1(P),5(EA),3(EB) Ports}

20.5

(36.7)

32.5

(40.2)

40

0.3mm2

15

EA 2-2.2 (Positioning for manifold gasket)

EB

(20)

32.5 27.2 (45)

10.5

Plug connector with cover type (LL) 52-SY5120-LL-01(-F2)


Insulation: red(+) Insulation: black(-)

4.1

0.3mm2 L (Lead wire length)

14.7

104

Terminal type (TT) 52-SY5120-TT-01(-F2)


Lead wire marking No.1(+), No.2(-) 5.9

0.75mm 2 L (Lead wire length) Max.10

12

120.8

64

1.2

29

5 Port Solenoid Valve

Series 52-SY

Dimensions

Body ported type Dimensions/Series 52-SY5000 2-position double Plug connector type (L) 52-SY5220-L-01(-F2)

22.6 16.7 2-M3 Threads depth 3.5 (For bracket mounting) 65.4 B A 16.2 36 37 Manual override 2-3.2 (Mounting holes for manifold) 2-1/8" {4(A),2(B) Port} 2-3.2 (Mounting holes) (40.2) L (Lead wire length) 3-1/8" {1(P),5(EA),3(EB) Ports} 1.6 1.55 153.6 (76.8) 0.8 EA 2-2.2 (Positioning for manifold gasket) P EB 27.2 (45) (88.5) 15 (20) 143.4 14.7 (71.7) 177 12 20.5 32.5 (36.7) 0.3mm 2 44 (For E type) 11.6

Insulation Black(-) Insulation Red(+)

(1.2) (11.7)

Plug connector with cover type (LL) 52-SY5220-LL-01(-F2)


L (Lead wire length)
Insulation: Red(+) Insulation :Black(-) 4.1

0.3mm2

Terminal type (TT) 52-SY5220-TT-01(-F2)


Max.10 L (Lead wire length)
Lead wire marking No.1(+), No.2(-) 5.9

0.75mm2

14.7

40

65

Series 52-SY
Dimensions

Body ported type Dimensions/Series 52-SY5000 3-position closed centre-exhaust centrepressure centre Plug connector type (L) 3 2-M3 threads depth 3.5 52-SY5420-L-01(-F2) (For bracket mounting) 5 32.7
Insulation Black(-) A Insulation Red(+) Manual override

22.6 16.7 (89.4) 45.3 11.6 B 2-3.2 (Mounting holes for manifold) 2-1/8" {4(A),2(B) Port} 2-3.2 (Mounting holes) 16.2 36 (37)

44 (For E type)

0.3mm 2 40

(40.2)

14.7

(1.2)

1.55

L (Lead wire length) 3-1/8" {1(P),5(EA),3(EB) Ports} 1.6

166.2 89.4 0.8

20.5

EA 2-2.2 (Positioning for manifold gasket)

EB

27.2 (45)

Plug connector with cover type (LL) 3 52-SY5420-LL-01(-F2) L 5 (Lead wire length)
Insulation: Red(+) Insulation: Black(-) 4.1

156

0.3mm 2

14.7

84.3

Terminal type (TT) 3 52-SY5420-TT-01(-F2) Max.10 5 L


(Lead wire length) Lead wire marking No.1(+), No.2(-) 5.9

189.6

0.75mm 2

12

101.1

66

(20)

15

32.5

(36.7)

5 Port Solenoid Valve

Series 52-SY

Dimensions

Body ported type Dimensions/Series 52-SY7000 2-position single Plug connector type (L) 52-SY7120-L-02(-F2)
2-M4 threads depth 6.5 (For bracket mounting) 20 29.4 7

In case with foot bracket 52-SY7120-L-02-(F1)

57 46 5.5

19.8 79.2 Insulation Black(-) Insulation Red(+) (14) 1.2 Manual override 13.6 B A 20 42 (52) 40 14.7 2-4.2 (Mounting holes for manifold) 2-1/4" {4(A),2(B) Port} 2-4.2 (Mounting holes) 14.7 24.5 (42.5) 0.3mm 2 40 44 (For E type) 40 (49.5) (39.4) L (Lead wire length) 1/4" {1(P) Port} 123.3 0.9 39.4 2 2-1/8" {5(EA),3(EB) Ports} EA 2-2.2 (Positioning for manifold gasket) 36 (66) P EB (23.9) 18 39.5 13

28 125

Plug connector with cover type (LL) 52-SY7120-LL-02(-F2)


Insulation: Red(+) Insulation: Black(-)

L (Lead wire length)

14.7

0.3mm 2

4.1

118.2

Terminal type (TT) 52-SY7120-TT-02(-F2)


Lead wire marking No.1(+), No.2(-) 5.9

L (Lead wire length)

12

0.75mm 2

135 Max.10

1.2

38

67

Series 52-SY
Dimensions

Body ported type Dimensions/Series 52-SY7000 2-position double Plug connector type (L) 52-SY7220-L-02(-F2)

20

2-M4 threads depth 6.5 (For bracket mounting) 7

79.6 Insulation Black(-) Insulation Red(+) A 20 42 (52) 2-4.2 (Mounting holes) 44 (For E type) 0.3mm 2 40 14.7 B 13.6 Manual override 2-4.2 (Mounting holes for manifold) 2-1/4" {4(A),2(B) Port}

(49.5)

(1.2) (14)

L (Lead wire length)

1.55

167.8 1/4" {1(P) Port} 2 (83.9) 0.9

2-1/8" {5(EA),3(EB) Ports}

EA 36 (66)

EB

18

24.5

2-2.2 (Positioning for manifold gasket)

Plug connector with cover type (LL) 52-SY7220-LL-02(-F2)


L (Lead wire length) Insulation: Red(+) Insulation: Black(-) 157.6

0.3mm 2 (78.8)

Terminal type (TT) 52-SY7220-TT-02(-F2)


Max.10 L (Lead wire length) Lead wire marking No.1(+), No.2(-) 5.9 191.2

0.75mm 2 (95.6)

68

4.1

(23.9)

(42.5)

40

5 Port Solenoid Valve

Series 52-SY

Dimensions

Body ported type Dimensions/Series 52-SY7000 3-position closed centre-exhaust centrepressure centre Plug connector type (L) 3 52-SY7420-L-02(-F2) 5
Insulation Black(-) Insulation Red(+)

20

2-M4 Threads depth 6.5 (For bracket mounting) 7

39.8

52.8 B 13.6

Manual override

A 20 42 (52)

2-4.2 (Mounting holes for manifold) 2-1/4" {4(A),2(B) Port} 2-4.2 (Mounting holes)

(49.5)

14.7

(1.2) (14)

L (Lead wire length)

1.55

180.8 1/4" {1(P) Port} 2 96.9 0.9 EA 36 (66) P EB 91.8 108.6 (23.9) 18

2-1/8" {5(EA),3(EB) Ports}

2-2.2 (Positioning for manifold gasket)

Plug connector with cover type (LL) 3 52-SY7420-LL-02(-F2) L 5 (Lead wire length)
4.1 Insulation: Red(+) Insulation: Black(-)

170.6

0.3mm 2

Terminal type (TT) 3 52-SY7420-TT-02(-F2) Max.10 5 L


(Lead wire length) Lead wire marking No.1(+), No.2(-) 5.9

204.2

0.75mm 2

24.5

(42.5)

0.3mm 2 40

44 (For E type)

40

69

Series 52-SY
Dimensions

Insulation Red(+)

Manual override 33.6 64.2 3-3.2 (Mounting holes of manifold) 2-1/4",3/8" {4(A),2(B) Port}

46 (For E type)

0.3mm2 42

18.4

Body ported type Dimensions/Series 52-SY9000 2-position single Insulation Plug connector type (L) Black(-) 02 52-SY9120-L-03

109.3 6.5 4A 56.3 2B

16.7

1.55

(12) L (Lead wire length)

2-4.4 (Mounting holes) 153.4

24.9

43.85

5EA 49.8

1P

3EB 0.5

Plug connector with cover type (LL) 02 52-SY9120-LL-03

4.1

Insulation: Red(+) Insulation: Black(-)

0.3mm2 L (Lead wire length)

14.7

148.3

Terminal type (TT) 02 52-SY9120-TT-03

Lead wire marking No.1(+), No.2(-)

0.75mm 2 L (Lead wire length) 165.1 Max.10

70

23

0.5

3-1/4" {1(P),3(EB),5(EA) Ports}

56.3

10

36.6

51.5

5 Port Solenoid Valve

Series 52-SY

Dimensions

Body ported type Dimensions/Series 52-SY9000 2-position double Insulation Plug connector type (L) Black(-) 52-SY9220-L-02 03
Insulation Red(+) Manual override

106 18.4 2B 33.6 64.2 3-3.2 (Mounting holes for manifold) 2-1/4",3/8" {4(A),2(B) Port} 24.9 194.2 10 36.6 97.1 0.5 1P 49.8 3EB 0.5 23 5EA 51.5 6.5 4A

16.7

1.55

(12) L (Lead wire length)

2-4.4 (Mounting holes)

3-1/4" {1(P),3(EB),5(EA) Ports}

Plug connector with cover type (LL) 02 52-SY9220-LL-03

4.1

Insulation: Red(+) Insulation: Black(-)

0.3mm 2 L (Lead wire length)

14.7

46 (For E type) 184 217.6

0.3mm2 42

Terminal type (TT) 52-SY9220-TT-02 03

Lead wire marking No.1(+), No.2(-)

0.75mm 2 L (Lead wire length) Max.10

71

Series 52-SY
Dimensions

Body ported type Dimensions/Series 52-SY9000 2-position closed centre - exhaust centre Insulation pressure centre Black(-) Plug connector type (L) 3 02 Manual override 52-SY9420-L-03 Insulation Red(+) 5

123 6.5 4A 2B 18.4 33.6 64.2 3-3.2 (Mounting holes for manifold) 2-1/4",3/8" {4(A),2(B) Port} 24.9 210.7 10 5EA 49.8 1P 3EB 0.5 (108.5) 201 (125.3) 234.1 23 0.5 36.6 51.5 113.6

16.7

1.55

(12) L (Lead wire length)

2-4.4 (Mounting holes)

3-1/4" {1(P),3(EB),5(EA) Ports}

Plug connector with cover type (LL) 3 02 52-SY9420-LL-03 5


Insulation: Red(+) Insulation: Black(-) 0.3mm2 L (Lead wire length) 4.1

Terminal type (TT) 3 52-SY9420-TT-02 03 5


Lead wire marking No.1(+), No.2(-)

0.75mm 2 L (Lead wire length) Max.10

72

14.7

46 (For E type)

0.3mm2 42

5 Port Solenoid Valve

Series 52-SY

Dimensions

Base mounted type Dimensions/Series 52-SY5000 2-position single Plug connector type (L) 52-SY5140(R)-L-02

37.2 15.5 17.5 Insulation Black(-) Insulation Red(+)

A A EA P 56 65 109.1

B 35 B EB 4.3 62.5

2-4.3 (Mounting holes) Manual override

60.3 48 8.3 M5 (External pilot port) 15.5

9.5

18

19

X 17

PE
17 M5 (Pilot EXH. port) <For external pilot type>

1.55

0.3mm2

66.5 (For E type)

L (Lead wire length)

18

18 28

Plug connector with cover type (LL) 52-SY5140(R)-LL-02


Insulation: Red(+) Insulation: Black(-) L (Lead wire length) 104

4.1

0.3mm 2

Terminal type (TT) 52-SY5140(R)-TT-02


L (Lead wire length) Lead wire marking No.1(+), No.2(-)

Max.10 120.8

5.9

0.75mm2

34.5

37.2

9.5

5-1/4" (Piping ports)

22

73

Series 52-SY
Dimensions

Base mounted type Dimensions/Series 52-SY5000 2-position double Plug connector type (L) 52-SY5240(R)-L-02
37.2 15.5 17.5 Insulation Black(-) 2-4.3 (Mounting holes) Manual override A A EA

18

19 9.5

48 B B EB

4 4

M5 (External pilot port)

15.5 17.5 X 17 62.5

PE
17 M5 (Pilot EXH. port) <For external pilot type>

Insulation Red(+)

P 56 65.4 153.6

1.55

0.3mm 2

66.5 (For E type)

L (Lead wire length)

9.5 5-1/4" (Piping ports) (71.7) (88.5)

18

18 28

Plug connector with cover type (LL) 52-SY5240(R)-LL-02


Insulation: Red(+) Insulation: Black(-) L (Lead wire length) 143.4

4.1

0.3mm2

Terminal type (TT) 52-SY5240(R)-TT-02


Max.10 L (Lead wire length) Lead wire marking No.1(+), No.2(-) 177

5.9

0.75mm 2

74

34.5

37.2

22

35

5 Port Solenoid Valve

Series 52-SY

Dimensions

Base mounted type Dimensions/Series 52-SY5000 3-position closed centre - exhaust centre pressure centre Plug connector type (L) 3 52-SY5440(R)-L-02 5
37.2 15.5 17.5 Insulation Black(-) 2-4.3 (Mounting holes) Manual override A A EA

18

19 9.5

48 B B EB

4 4

M5 (External pilot port)

15.5 17.5 X 17 62.5

17 M5 (Pilot EXH. port) <For external pilot type>

Insulation Red(+)

P 56

78 166.2 L (Lead wire length)

1.55

0.3mm2

66.5 (For E type)

5-1/4" (Piping ports)

Plug connector with cover type (LL) 3 52-SY5440(R)-LL-02 L 5


Insulation: Red(+) Insulation: Black(-) 0.3mm2 (Lead wire length)

156

4.1

37.2

84.3

Terminal type (TT) 3 52-SY5440(R)-TT-02 5 L


Lead wire marking No.1(+), No.2(-)

Max.10 189.6

(Lead wire length)

5.9

0.75mm 2

34.5

9.5

18

18 28

89.4

101.1

22

35 44.1

PE

75

Series 52-SY
Dimensions

Base mounted type Dimensions/Series 52-SY7000 2-position single Plug connector type (L) 52-SY7140(R)-L-02

21

22.5 13.5

41.7 21.5 Manual override 23 Insulation Black(-)

79.2 61 2-4.3 (Mounting holes) A A Insulation Red(+) EA P 69 123.3 B 38 B EB 6.4 67.2 21.5 46 10.4 21 M5 (External pilot port) 4

PE

21 M5 (Pilot EXH. port) <For external pilot type> L (Lead wire length) 1.55 0.3mm 2

71.2 (For E type)

11.5

5-3/8",1/4" (Piping ports)

20.5

20.5 33

Plug connector with cover type (LL) 52-SY7140(R)-LL-02


L (Lead wire length) Insulation: Red(+) Insulation: Black(-) 118.2

4.1

0.3mm 2

Terminal type (TT) 52-SY7140(R)-TT-02


Lead wire marking No.1(+), No.2(-)

L (Lead wire length)

Max.10

41.7

135

5.9

0.75mm 2

76

39

13.5

26.5

5 Port Solenoid Valve

Series 52-SY

Dimensions

Base mounted type Dimensions/Series 52-SY7000 2-position double Plug connector type (L) 52-SY7240(R)-L-02

41.7 21.5 Insulation Black(-) Insulation Red(+) 21 M5 (Pilot EXH. port) <For external pilot type> Manual override A A EA

61

13.5 2-4.3 (Mounting holes) 4

21

22.5

21

M5 (External pilot port) 23

23

B 38 X EB 21.5 67.2 (78.8) (95.6) 11.5 13.5 26.5 B P 69 79.6 167.8 46

0.3mm2

71.2 (For E type)

1.55

Plug connector with cover type (LL) 52-SY7240(R)-LL-02


Insulation: Red(+) Insulation: Black(-) L (Lead wire length)

4.1

Terminal type (TT) 52-SY7240(R)-TT-02


Lead wire marking No.1(+), No.2(-) L (Lead wire length)

Max.10 191.2

0.75mm 2

5.9

39

41.7

PE
0.3mm 2

L (Lead wire length)

5-3/8",1/4" (Piping ports)

20.5 20.5 33

157.6

77

Series 52-SY
Dimensions

Base mounted type Dimensions/Series 52-SY7000 3-position closed centre - exhaust centre pressure centre Plug connector type (L) 3 52-SY7440(R)-L-02 5
41.7 21.5 Insulation Black(-) Insulation Red(+) 21 M5 (Pilot EXH. port) <For external pilot type> 71.2 (For E type) L (Lead wire length) 0.3mm 2 1.55 Manual override A A EA

61

13.5 2-4.3 (Mounting holes)

21

22.5

21

M5 (External pilot port) 23

23

B 38 X EB 21.5 44.1 67.2 91.8 11.5 96.9 13.5 108.6 26.5 B P 69 92.6 180.8 46

5-3/8",1/4" (Piping ports)

20.5 20.5 33

Plug connector with cover type (LL) 3 52-SY7440(R)-LL-02 5


Insulation: Red(+) Insulation: Black(-) L (Lead wire length)

170.6

4.1

0.3mm2

Terminal type (TT) 3 52-SY7440(R)-TT-02 5 Lead wire marking


No.1(+), No.2(-)

41.7

Max.10 L (Lead wire length) 204.2

0.75mm 2

5.9

78

39

PE

5 Port Solenoid Valve

Series 52-SY

Dimensions

Base mounted type Dimensions/Series 52-SY9000 2-position single Plug connector type (L) 02 52-SY9140(R)-L-03

29

30 17.5

109.3 51.2 25 Manual override Insulation Black(-) 86.5 2-5.4 (Mounting holes) A4 B2 B 1P 96.5 153.4 3EB 11.8 76.5 25 47 57 16.8 1/8" (External pilot port) 27

28.5

PE

A
Insulation Red(+) 27 1/8" (Pilot EXH. port) <For external pilot type> L (Lead wire length) 0.3mm 2 1.55 80.5 (For E type) 5EA

29.5 5-3/8",1/2" (Piping ports)

29.5 44.5

Plug connector with cover type (LL) 02 52-SY9140(R)-LL-03


L (Lead wire length) Insulation: Red(+) Insulation: Black(-) 148.3

4.1

0.3mm 2

Terminal type (TT) 52-SY9140(R)-TT-02 03


L (Lead wire length) Lead wire marking No.1(+), No.2(-)

Max.10 165.1

5.9

0.75mm 2

48.5

51.2

15.5

17.5

34

79

Series 52-SY
Dimensions

Base mounted type Dimensions/Series 52-SY9000 2-position double Plug connector type (L) 02 52-SY9240(R)-L-03

29

30 17.5

106 51.2 25 Manual override Insulation Black(-) 86.5 2-5.4 (Mounting holes) 4A 2B B 1P 96.5 194.2 76.5 3EB 25 47 57 5

1/8" (External pilot port)

27

28.5

PE

A
Insulation Red(+) 27 1/8" (Pilot EXH. port) <For external pilot type> L (Lead wire length) 0.3mm 2 1.55 80.5 (For E type) 5EA

29.5 5-3/8",1/2" (Piping ports)

29.5 44.5

Plug connector with cover type (LL) 02 52-SY9240(R)-LL-03


Insulation: Red(+) Insulation: Black(-)

L (Lead wire length)

184

4.1

0.3mm 2

51.2

Terminal type (TT) 52-SY9240(R)-TT-02 03


Lead wire marking No.1(+), No.2(-)

Max.10 L (Lead wire length) 217.6

5.9

0.75mm2

48.5

80

15.5 (92) (108.8)

17.5

34

5 Port Solenoid Valve

Series 52-SY

Dimensions

Base mounted type Dimensions/Series 52-SY9000 3-position closed centre exhaust centre - Pressure centre Plug connector type (L) 3 02 52-SY9440(R)-L-03 5
51.2 25 Manual override Insulation Black(-)

29

30 17.5

123 86.5 2-5.4 (Mounting holes) A4 B2 B 1P 96.5 210.7 3EB 69.1 76.5 25 47 57 1/8" (External pilot port) 27

28.5

PE

A
Insulation Red(+) 27 1/8" (Pilot EXH. port) <For external pilot type> 5EA

1.55

0.3mm 2

80.5 (For E type)

L (Lead wire length)

29.5 5-3/8",1/2" (Piping ports)

29.5 44.5

113.6

Plug connector with cover type (LL) 3 02 52-SY9440(R)-LL-03 L (Lead wire length) 5
Insulation: Red(+) Insulation: Black(-)

200

4.1

0.3mm 2

51.2

15.5

17.5

Terminal type (TT) 3 52-SY9440(R)-TT-02 03 5 Lead wire marking


No.1(+), No.2(-) 0.75mm 2

Max.10 L (Lead wire length) 234.1

5.9

48.5

34 108 125.3

81

5 Port Solenoid Valve


(+COM, -COM common)

Series 56-SV
II 3GD EEx nA II T5X T90 IP67
For more details, other specifications, dimensions, see the specific catalogue

How to Order

56 - SV 1 1 0 0
ATEX category 3 Series
1 2 3 4 56-SV1000 56-SV2000 56-SV3000 56-SV4000

5 F Z
Manual override
Nil D Non lock/ Push type Push turn lock type Driver operation type

Indicator light and surge voltage suppressor


S Z With surge voltage suppressor With indicator light/ surge voltage suppressor

Configuration
2-position single solenoid 1 2-position double solenoid 2 3-position closed centre 3 3-position exhaust centre 4 3-position pressure centre 5 4-position dual 3 port valve: N.C./N.C. A 4-position dual 3 port valve: N.O./N.O. B 4-position dual 3 port valve: N.C./N.O. C * 4-position dual 3 port valve is only available in 56-SV1000 and 2000 series.

Rated voltage
24VDC 5 12VDC 6 * Only 24VDC is applicable to the 56-EX500 series.

Back pressure check valve

Not built-in Nil Built-in K Pilot * Backpressure check valve type is only Internal pilot Nil available in the 56-SV1000 series External pilot R * Backpressure check valve is not incorporated * External pilot specification is not in the 3-position closed centre and 3-position available in 4-position dual 3-port valve. pressure center configurations.

Part No. for blanking plate assembly

SV 1 000
Series
1 2 3 4 56-SV1000 56-SV2000 56-SV3000 56-SV4000

67

1A

82

5 Port Solenoid Valve

Series

56-SV
II 3GD EEx nA II T5X T90C IP67

For more details, other specifications, dimensions, see the specific catalogue

How to Order

56 - SS5V 1 W 10 N S A2W D 06 U R
ATEX category 3 Series
1 2 3 4 56-SV1000 56-SV2000 56-SV3000 56-SV4000

Applicable to Serial 56-EX500> Manifold numbering system (Base piping type/ Tie rod base)

C6

Position of P, E port
U D B U side (4 to 10 stations) D side (4 to 10 stations) Both sides (4 to 10 stations)

IP67 specification

SUP/EXH block ass'y specification


Nil R Internal pilot specification External pilot specification

Manifold base common specification


Nil N +COM -COM

A, B port size (mm)


Symbol C3 C4 C6 C4 C6 C8 C6 C8 C10 C8 C10 C12 02 03 02F 03F M Symbol N1 N3 N7 N3 N7 N9 N7 N9 N11 N9 N11 02N 03N 02T 03T M A & B port 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting 8 One-touch fitting 10 One-touch fitting 12 One-touch fitting Rc 1/4 Rc 3/8 G 1/4 G 3/8 Mixture of A and B ports A & B port 1/8" One-touch fitting 5/32" One-touch fitting 1/4" One-touch fitting 5/32" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 3/8" One-touch fitting 5/16" One-touch fitting 3/8" One-touch fitting NPT 1/4 NPT 3/8 NPTF 1/4 NPTF 3/8 Mixture of A and B ports P & E port 8 One-touch fitting 10 One-touch fitting 12 One-touch fitting 12 One-touch fitting Rc 3/8 G 3/8 Series 56-SV1000 series 56-SV2000 series 56-SV3000 series

SI unit
Applicable to Profibus A2W For gateway (+COM) Applicable to Profibus A2WN For gateway (-COM) * Common specification for manifold and SI unit should be identical.

56-SV4000 series

Manifold station
04 06 08 04 06 08 10 4 stations 6 stations 8 stations 4 stations 6 stations 8 stations 10 stations Double wiring
Note1)

A, B port size (inch)


Specified layout (Possible upto 16 solenoids)
Note2)

P & E port

Series

5/16" One-touch 56-SV1000 fitting series 3/8" One-touch fitting 3/8" One-touch fitting 3/8" One-touch fitting NPT 3/8 NPTF 3/8 56-SV4000 series 56-SV2000 series 56-SV3000 series

Only the manifold stations above are available. When a valve number does not correspond to a manifold station, use a blanking plate to match both numbers. Note1) Double wiring specification: single, double, 3-position, and 4-position solenoid valve can be used for all manifold station. When using a single solenoid, some control signals will not be counted. Therefore, specify the signal layout at the time an order is placed. Note2) Layout specification: Please use the Manifold Specification Sheet to provide wiring. (The double solenoid valve and 3-position or 4-position solenoid valve are not available when single wiring is specified. Please note this.)

Note 1: Please complete the Manifold Specification Sheet when specifying the mixture specification (M). Note2: For the external pilot specification (R), the X and PE port size are as follows: - 4mm or 5/32" for the 56-SV1000 and 56-SV2000 series - 6mm or 1/4" for the 56-SV3000 and 56-SV4000 series

83

5 Port Solenoid Valve

Series

56-SV
II 3GD EEx nA II T5X T90 IP67

For more details, other specifications, dimensions, see the specific catalogue

How to Order

56 - SS5V 1 W 10 N CD 06 U R
ATEX category 3 Series
1 2 3 4 56-SV1000 56-SV2000 56-SV3000 56-SV4000

Applicable to multi-connector> Manifold numbering system (Base piping type/ Tie rod base)

C6

Position of P, E port
U D B U side (4 to 10 stations) D side (4 to 10 stations) Both sides (4 to 10 stations)

Voltage specification
Nil 12V 24VDC 12VDC

IP67 specification

SUP/EXH block assembly specification


Nil R Internal pilot specification External pilot specification

* Please pay attention to the polarity because a diode for protecting against miswiring is not incorporated in the 12VDC version.

Manifold base common specification


Nil N +COM -COM

A, B port size (mm)


Symbol C3 C4 C6 C4 C6 C8 C6 C8 C10 C8 C10 C12 02 03 02F 03F M Symbol N1 N3 N7 N3 N7 N9 N7 N9 N11 N9 N11 02N 03N 02T 03T M A & B port 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting 8 One-touch fitting 10 One-touch fitting 12 One-touch fitting Rc 1/4 Rc 3/8 G 1/4 G 3/8 Mixture of A and B ports A & B port 1/8" One-touch fitting 5/32" One-touch fitting 1/4" One-touch fitting 5/32" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 3/8" One-touch fitting 5/16" One-touch fitting 3/8" One-touch fitting NPT 1/4 NPT 3/8 NPTF 1/4 NPTF 3/8 Mixture of A and B ports P & E port 8 One-touch fitting 10 One-touch fitting 12 One-touch fitting 12 One-touch fitting Rc 3/8 G 3/8 Series 56-SV1000 series 56-SV2000 series 56-SV3000 series

56-SV4000 series

Manifold station
04 06 08 10 04 06 08 10 4 stations 6 stations 8 stations 10 stations 4 stations 6 stations 8 stations 10 stations Double wiring
Note1)

A, B port size (inch)


P & E port Series 5/16" One-touch 56-SV1000 fitting series 3/8" One-touch fitting 3/8" One-touch fitting 3/8" One-touch fitting NPT 3/8 NPTF 3/8 56-SV4000 series 56-SV2000 series 56-SV3000 series

Specified layout
Note2)

Only the manifold stations above are available. When a valve number does not correspond to a manifold station, use a blanking plate to match both numbers. Note1) Double wiring specification: single, double, 3-position, and 4-position solenoid valve can be used for all manifold station. When using a single solenoid, some control signals will not be counted. Therefore, specify the signal layout at the time an order is placed. Note2) Layout specification: Please use the Manifold Specification Sheet to provide wiring. (The double solenoid valve and 3-position or 4-position solenoid valve are not available when single wiring is specified. Please note this.)

Note 1: Please complete the Manifold Specification Sheet when specifying the mixture specification (M). Note2: For the external pilot specification (R), the X and PE port size are as follows: - 4mm or 5/32" for the 56-SV1000 and 56-SV2000 series - 6mm or 1/4" for the 56-SV3000 and 56-SV4000 series

84

5 Port Solenoid Valve

Series 56-SV

Dimensions

Conform to ATEX directive Dimensions/ Series 56-SV1000 Circular Connector Tie-rod base manifold: 56-SS5V1-W10CD- Stations

U D B

(R)-

C3,N1 C4,N3 C6,N7

*When P,E port outlets are indicated on the U side or D side, the P,E ports on the opposite side are plugged. *External pilot port positions are the same as P,E port outlet positions.

With external pilot specification 18.3 8.6 (pitch) P=10.5 13.5 60.6 14.1 8.4

24.6 23 10

56.5 43

One-touch fitting [4(A),2(B) port] Applicable tubing O.D.:3.2,1/8" 4, 5/32" 6, 1/4" L1 L2 (C6:3.2) (N7:7) (4.9) 47.8 43.7 D side

U side

One-touch fitting [X:External pilot port] Applicable tubing O.D.:4 5/32"

One-touch fitting [PE:Pilot EXH.port] Applicable tubing O.D.:4 5/32"

Earth terminal (M4)

92.2 83.7 83 10.8

58.9 71.3 92.6

18

19

17

26

20

15

16

25

21

24

14

23

22

13

12

11

10

29.6

4.6 6.2

26.4

4-4.3 (For mounting)

4(A) port side:Orange 2(B) port side:Green

(Press and turn for ) the locking type.

Manual override

27.5 Notch (To align connector position)

(Station n) (Station 1) Light/Surge voltage suppressor (Cable assembly) (Min.bending radius 20mm)

8.9 2.7

L:dimensions n:stations

67.5 59.5 45.5

10

(81) (When circular connector is mounted)

52.2

6 8 10 L n 4 L1 137.3 158.3 179.3 200.3 L2 84 105 126 147

38.4

PE

PE

One-touch fitting [1(P),3/5(E) port] Applicable tubing O.D.:10 5/16"

3 5

4 2

A4 B2

A4 B2

A4 B2

A B

3 5

3/5

4 2
B

A4 B2
B

A4 B2
B

A4 B2
B

A B

3/5 1

85

Series 56-SV
Dimensions

Conform to ATEX directive Dimensions/ Series 56-SV1000 56-EX500 Decentralised Serial Wiring Tie-rod base manifold: 56-SS5V1-W10SAWD- Stations
*When P,E port outlets are indicated on the U side or D side, the P,E ports on the opposite side are plugged. *External pilot port positions are the same as P,E port outlet positions.

U D B

(R)-

C3,N1 C4,N3 C6,N7

With external pilot specification (pitch) P=10.5 18.3 23 9.5


4 A4 A4 A4 A

13.5

46.9 11.8 8.6

14.1

8.4
4 A4 B2 A4 B2 A4 B2 A

19.7 24.6 43.2

56.5

43

One-touch fitting [4(A),2(B) port] Applicable tubing O.D.:3.2,1/8" 4,5/32" 6,1/4" D side L1 L2 (C6:3.2) (N7:7) 34.1 SI unit (4.9) 9.2

U side

Earth terminal (M4)

92.2 83 83.7 29.6 10.8

PWR COM

68.5 92.6 108.5

9.5

4.6

4-4.3 (For mounting)

Manual override Press and turn for the locking type. 4(A) port side:Orange 2(B) port side:Green (Station n) (Station 1)

Light/Surge voltage suppressor L:dimensions n:stations 67.5 59.5 45.5 58.7 65.4
6 8 10 L n 4 L1 123.6 144.6 165.6 186.6 L2 84 105 126 147

86

10

6.2

9.6

3.4

26.4

C1

One-touch fitting [1(P),3/5(E) port] Applicable tubing O.D.:8 5/16"

2-M12

One-touch fitting [X:External pilot port] Applicable tubing O.D.:4 5/32"

One-touch fitting [PE:Pilot EXH.port] Applicable tubing O.D.:4 5/32"

C1

PE

PE

C2

E P

3 5 1 2 B

E P

3 5 1

C2

E P

3 5 1 2
B

B2

B2

B2

E P

3 5 1

5 Port Solenoid Valve

Series 56-SV

Dimensions

Conform to ATEX directive Dimensions/ Series 56-SV2000 Circular Connector Tie-rod base manifold: 56-SS5V2-W10CD- Stations

U D B

(R)-

C4,N3 C6,N7 C8,N9

*When P,E port outlets are indicated on the U side or D side, the P,E ports on the opposite side are plugged. *External pilot port positions are the same as P,E port outlet positions.

20.5 11.9 9.2

(pitch) P=1617.5

60.7

With external pilot specification 15.8 9.5

30.6 25.2

63.5 49.9

One-touch fitting [4(A),2(B) port] Applicable tubing O.D.:4,5/32" 6,1/4" 8,5/16" D side L1 L2 (4.9) (5.3) 46.2 43.7

U side 4-5.3 (For mounting) Earth terminal (M4)

One-touch fitting [PE:Pilot EXH port] Applicable tubing O.D.:4 5/32"

One-touch fitting [X:External pilot port] Applicable tubing O.D.:4 5/32"

115.5 97.5

A
B

A
B

58.9 71.3 102.9 109.4

18

19

17

29.6 12.2

26

20

15

16

25

21

24

14

23

22

13

12

11

10

5.4 6.2

11.4 5.2

26.4

4(A) port side:Orange 2(B) port side:Green

(Press and turn for ) the locking type.

Manual override

29.5 Notch (To align connector position)

(Station n) Light/Surge voltage suppressor

(Station 1) (Cable assembly) (Min.bending radius 20mm)

71.5 63.5 52.5

54.2

L:dimensions n:stations

6 8 10 L n 4 L1 164.2 196.2 228.2 260.2 L2 112 144 176 208

12

(81) (When circular connector is mounted)

40.8

PE

PE

One-touch fitting [1(P),3/5(E) port] Applicable tubing O.D.:10 3/8"

E P

3/5 1 B 2 B 2 B 2 B 2

4 A

4 A

4 A

4 E P 3/5 1

E P P

3/5 1 1 B
B

4 A 2 B
B

4 A 2 B
B

4 A
2 B 2 B
B

4
2 2 P P 1 1

3/5

87

Series 56-SV
Dimensions

Conform to ATEX directive Dimensions/ Series 56-SV2000 56-EX500 Decentralised Serial Wiring Tie-rod base manifold: 56-SS5V2-W10SAWD- Stations
*When P,E port outlets are indicated on the U side or D side, the P,E ports on the opposite side are plugged. *External pilot port positions are the same as P,E port outlet positions.

U D B

(R)-

C4,N3 C6,N7 C8,N9

(pitch) P=1617.5 20.5

46.5 11.8

With external pilot specification 15.8 9.5

30.6 25.2 11.9 9.2

20.6 44.1

63.5 49.9

(4.9)

(5.3)

U side 4-5.3 (For mounting) Earth terminal (M4)

L1 L2

One-touch fitting [4(A),2(B) port] Applicable tubing O.D.:4,5/32" 6,1/4" 8,5/16" D side 9.2 32 SI unit

One-touch fitting [PE:Pilot EXH port] Applicable tubing O.D.:4 5/32"

One-touch fitting [X:External pilot port] Applicable tubing O.D.:4 5/32"

A
B

A
B

29.6 12.2

PWR COM

68.5 102.9 109.4 108.5

115.5 97.5

9.5

10.7

5.4 6.2

4(A) port side:Orange 2(B) port side:Green

(Press and turn for) the locking type.

Manual override

(Station n) Light/Surge voltage suppressor

(Station 1)

4.5

26.4

L:dimensions n:stations

71.5 63.5 52.5

6 8 10 L n 4 L1 150 182 214 246 L2 112 144 176 208

88

12

59.6 66.3

PE

PE

One-touch fitting [1(P),3/5(E) port] Applicable tubing O.D.:10 3/8"

C1

2-M12

C2

E P

3/5 1

A B

4A 2B

4A 2B

4A 2B

4 2

3/5 1

C1

C2

E P

3/5 1

A B
B

4A 2B
B

4A 2B
B

4A 2B
B

4 2

E P

3/5 1

5 Port Solenoid Valve

Series 56-SV

Dimensions

Conform to ATEX directive Dimensions/ Series 56-SV3000 Circular Connector Tie-rod base manifold: 56-SS5V3-W10CD- Stations

U D B

(R)-

C6,N7 C8,N9 C10,N11

*When P,E port outlets are indicated on the U side or D side, the P,E ports on the opposite side are plugged. *External pilot port positions are the same as P,E port outlet positions.

With external pilot specification 23.5 11.6 (pitch) P=20.5 21.3 61.3 18 11

37.6 36.1 13.5

76.8 60.3

One-touch fitting [4(A),2(B) port] Applicable tubing O.D.:6 ,1/4" 8 ,5/16" 10,3/8" D side L2 (5.3) L1 (5.1) 44.3 43.7

U side

One-touch fitting [X:External pilot port] Applicable tubing O.D.:6 1/4"

One-touch fitting [PE:Pilot EXH.port] Applicable tubing O.D.:6 1/4"

Earth terminal (M4)

128.8 115.8 5 83.8 6.2 29.6 14.3

A B

A
B

A
4

58.9 71.3

18

19

17

26

20

15

16

25

21

24

14

23

22

13

12

11

10

10.1 3.9

26.4

4-5.3 (For mounting)

Manual override Press and turn for the locking type. 4(A) port side: Orange 2(B) port side: Green

42.8 Notch (To align connector position)

(Station n) Light/Surge voltage suppressor

(Station 1) (Cable assembly) (Min.bending radius 20mm) L:dimensions n:stations


6 8 10 L n 4 L1 188.8 229.8 270.8 311.8 L2 138 179 220 261

12

88.9 82.7 63.8

(81) (When circular connector is mounted)

39.6

PE

PE

One-touch fitting [1(P),3/5(E) port] Applicable tubing O.D.:12 3/8"

E P

3 5 A 1 B

4 A 2 B

4 A 2 B

4 A 2 B

4 E 2 P

3 5 1

E P

3 5 A 1 B
B

4 A 2 B
B

2 B

4 A
B

4 A 2 B
B

4 E 2 P

3 5 1

89

Series 56-SV
Dimensions

Conform to ATEX directive Dimensions/ Series 56-SV3000 56-EX500 Decentralised Serial Wiring Tie-rod base manifold: 56-SS5V3-W10SAWD- Stations
*When P,E port outlets are indicated on the U side or D side, the P,E ports on the opposite side are plugged. *External pilot port positions are the same as P,E port outlet positions.

U D B

(R)-

C6,N7 C8,N9 C10,N11

23.5

(pitch) P=20.5

With external pilot specification 21.3 48.6 11.8 11.6

18 11

36.1 13.5

36 37.6 59.5

76.8 60.3

One-touch fitting [1(P),3/5(E)port] Applicable tubing O.D.:12 3/8" U side 6.5 Earth terminal (M4) (5.3) L2 L1

2-M12

One-touch fitting [4(A),2(B) port] Applicable tubing O.D.:6 ,1/4" 8 ,5/16" 10,3/8" D side 31.6 (5.1) 9.2

One-touch fitting [X:External pilot O.D.] Applicable tubing O.D.:6 1/4"

One-touch fitting [PE:Pilot EXH port] Applicable tubing O.D.:6 1/4"

SI unit 9.5
B B B
B

128.8 115.8 5 83.8 6.2 29.6 14.3

A B

A
B

PWR

68.5 108.5

COM

4-5.3 (For mounting)

Manual override Press and turn for the locking type. 4(A) port side: Orange 2(B) port side: Green

(Station n) Light/Surge voltage suppressor

(Station 1)

10.1 3.9

88.9 82.7 63.8

L:dimensions n:stations 75 81.7

6 8 10 L n 4 L1 176.1 217.1 258.1 299.1 L2 138 179 220 261

90

12

26.4

C1

C2

E P
PE

3 5 A
X

2 B

4 A

4 A 2 B

4 A 2 B

4 E 2 P
PE

3 5
X

C1

C2

E P

3 5 A 1 B

4 A 2 B

4 A 2 B

4 A 2 B

4 E 2 P

3 5 1

5 Port Solenoid Valve

Series 56-SV

Dimensions

Conform to ATEX directive Dimensions/ Series 56-SV4000 Circular Connector Tie-rod base manifold: 56-SS5V4-W10CD- Stations

U D B

(R)- 03,C10,N9 C12,N11

02,C8,

*When P,E port outlets are indicated on the U side or D side, the P,E ports on the opposite side are plugged. *External pilot port positions are the same as P,E port outlet positions.

25

(pitch) P=24 24

With external pilot specification 65 20 11

35 14.5

13.7 35.8

74.8 58.3

Rc3/8 [1(P),3/5(E) port] Rc1/4,3/8 [4(A),2(B) port]

One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.:8,5/16" 10,3/8" 12 U side 4-6.2 (For mounting) Earth terminal (M4) L1

One-touch fitting [X:External pilot port] Applicable tubing O.D.:6 1/4"

One-touch fitting [PE:Pilot EXH port] Applicable tubing O.D.:6 1/4"

D side

L2 (5.4)

47.3

43.7

13.3 [for Rc1/4,3/8]

164.7 148.2

A
B

A
B

A
4

75

58.9 71.3 81.7

18

29.6 17.5

19

17

26

20

15

16

25

21

24

14

23

22

13

12

11

10

12.2 6

26.4

Manual override Press and turn for the locking type. 4(A) port side: Orange 2(B) port side: Green

33.8 Notch (To align connector position)

6.2

(Station n) Light/Surge voltage suppressor

(Station 1) (Cable assembly) (Min.bending radius 20mm) L:dimensions n:stations


L n

93.5 85.5 61.8

4 6 8 10 L1 210.8 258.8 306.8 354.8 L2 157 205 253 301

16.2

(84.5) (When circular connector is mounted)

58.5

41.6

PE

PE

One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.:12 3/8"

E P

3/5

1 B

4 A 2 B

4 A 2 B

4 A 2 B

4 E 2 P

3/5 1

E P

3/5

1 B

2 B

4 A

4 A 2 B

4 A 2 B

2 P

4 E

3/5 1

91

Series 56-SV
Dimensions

Conform to ATEX directive Dimensions/ Series 56-SV4000 56-EX500 Decentralised Serial Wiring Tie-rod base manifold: 56-SS5V4-W10SAWD- Stations
*When P,E port outlets are indicated on the U side or D side, the P,E ports on the opposite side are plugged. *External pilot port positions are the same as P,E port outlet positions.

U D B

(R)- 03,C10,N9 C12,N11

02,C8,

25

(Pitch) P=24 24

With external pilot specification 48.6 11.8 13.7 35.8 40.4 63.9

20 11
E
C1 C2

35 14.5

74.8 58.3

One-touch fitting [4(A),2(B) port] Applicable tubingO.D.: 8,5/16" 10,3/8" 12 U side L2 L1 (5.4)

2-M12 Rc3/8 [1(P),3/5(E) port] Rc1/4,3/8 [4(A),2(B) port] D side 30.1 9.2

One-touch fitting [X: External pilot port] Applicable tubing O.D.: 6 1/4"

One-touch fitting [PE:Pilot EXH.port] Applicable tubing O.D.:6 1/4"

4-6.2 (For mounting) Earth terminal (M4)

164.7 148.2

29.6 17.5

PWR COM

68.5 102.3 81.7

A
B

A
B

9.5

13.3 [with Rc1/4,3/8] 75

6.2

(Press and turn for ) the locking type.

Manual override

6.2

SI unit

4(A) port side: Orange 3(B) port side: Green

(Station n) Light/Surge voltage suppressor

(Station 1) L:dimensions n:stations

26.4

93.5 85.5 61.8

6 8 10 L n 4 L1 193.6 241.6 289.6 337.6 L2 157 205 253 301

92

16.2

79.4 86.1

PE

PE

C1

One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 12 3/8"

3/5

1 B

4 A 2 B

4 A 2 B

2 B

4 A

2 P

4 E

3/5 1

C2

E P

3/5

1 B

4 A 2 B

4 A 2 B

4 A 2 B

2 P

4 E

3/5 1

93

5-Port Solenoid Valve

Series

56-VQC1000
II 3GD EEx nA II T5X T85C IP67
For more details, other specifications, dimensions, see the specific catalogue.

How to Order Manifolds

56 - VV5QC 1 1 08 C6 TD0 N 56 - VV5QC 1 1 08 C6 SDA2 N


Series ATEX category 3
1 56-VQC1000
Nil

M / T F L S Kit
Options
None

Kit

Manifold model
1
Plug-in unit

B All stations with back pressure check valve D With DIN rail (rail length: standard) D With DIN rail (rail length: special) K N R
Special wiring specifications (except for double wiring) With name plate External pilot

Stations
01
1 station

The maximum number of stations differs depending on the electrical entry (refer to Electrical entry/Cable length).

COM.
N
() COM.

Cylinder port size


C3 C4 C6 M5 CM L3 L4 L6 L5 LM B3 B4 B6 B5 BM
With 3.2 One-touch fitting With 4 One-touch fitting With 6 One-touch fitting M5 thread Mixed sizes and with port plug Top ported elbow Wtih 3.2 One-touch fitting Top ported elbow With 4 One-touch fitting Top ported elbow With 6 One-touch fitting M5 thread Elbow port, mixture sizes Bottom ported elbow With 3.2 One-touch fitting Bottom ported elbow With 4 One-touch fitting Bottom ported elbowWith 6 One-touch fitting M5 thread Elbow for bottom port, mixture sizes

Kit designation/Electrical entry/Cable length

Kit (Multiple connector kit)

Kit (Terminal block box kit)

Kit (Serial output kit)

00 EX5 series

MD0 MD1 MD2 MD3

Multiple connector kit (26P) without cable Multiple connector kit (26P) with 1.5m cable 1 to 12 stations Multiple connector kit (26P) with 3.0m cable (24 stations) TD0 Terminal block box kit Multiple connector kit (26P) with 5.0m cable

1 to 10 stations (20 stations)

SDA2 PROFIBUS-DP

Serial kit for

1 to 8 stations (16 stations)

94

Series 56-VQC

Base-Mounted Type

Plug-in Unit

How to Order Valves

56 - VQC 1 1 0 0
ATEX category 3 Series
1 56-VQC1000

5
Manual override
Nil: Non-locking
push type (Slotted)

Coil voltage
5
24VDC

Type of actuation
1
2-position single (A)(B) 4 2
5 1 3 (R1)(P)(R2)

B: Locking type
(Slotted)

Note)

4-position dual 3-port valve (A) (B) (A) 4 2


5 3 (R1) 1 (R2) (P) N.C N.C 4-position dual 3-port valve (A) (B) (B) 4 2 5 3 (R1) 1 (R2) (P) N.O N.O 4-position dual 3-port valve (A) (B) (C) 4 2 5 (R1) N.C 3 1 (R2) (P) N.O

Function
Nil

Standard type External pilot

2-position double (metal) (A)(B) 4 2


5 1 3 (R1)(P)(R2)

C: Locking type
(Manual)

Note)

2-position double (rubber) (A)(B) 4 2


5 1 3 (R1)(P)(R2) 3-position closed centre (A)(B) 4 2 5 1 3 (R1)(P)(R2) 3-position exhaust centre (A)(B) 4 2 5 1 3 (R1)(P)(R2)

D: Slide locking type


(Manual)

Note)

Seal type
0 1
Metal seal Rubber seal

Note) For rubber seal type only.

Note) ''56-'' solenoid valve should be installed in ''56-VV5QC11'' manifold. Power consumption when starting is 1W, when maintaining 0.35W.

3-position pressure centre (A)(B) 4 2


5 1 3 (R1)(P)(R2)

95

5-Port Solenoid Valve

Series

56-VQC2000
II 3GD EEx nA II T5X T85C IP67
For more details, other specifications, dimensions, see the specific catalogue.

How to Order Manifolds

56 - VV5QC 2 1 08 C8 TD0 N 56 - VV5QC 2 1 08 C8 SDA2 N


Series ATEX category 3
2 56-VQC2000
Nil

M / T F L S Kit
Options
B D D K N R S T

Kit

Manifold model
1
Plug-in unit

Stations
01
1 station

None All stations with back pressure check valve With DIN rail (rail length: standard) With DIN rail (rail length: special) Special wiring specifications (except for double wiring) With name plate External pilot Direct exhaust with built-in silencer Branched P and R ports on U side

The maximum number of stations differs depending on the electrical entry (refer to Electrical entry/Cable length).

COM.
N
() COM.

Cylinder port size


C4 C6 C8 CM L4 L6 L8 LM B4 B6 B8 BM
With 4 One-touch fitting With 6 One-touch fitting With 8 One-touch fitting Mixed sizes and with port plug Top ported elbow With 4 One-touch fitting Top ported elbow With 6 One-touch fitting Top ported elbow With 8 One-touch fitting Elbow port, mixture sizes Bottom ported elbow With 4 One-touch fitting Bottom ported elbow With 6 One-touch fitting Bottom ported elbow With 8 One-touch fitting Elbow for bottom port, mixture sizes

Kit designation/Electrical entry/Cable length

Kit (Multiple connector kit)

Kit (Terminal block box kit)

Kit (Serial output kit)

0 EX50 series

MD0 MD1 MD2 MD3

Multiple connector kit (26P) without cable Multiple connector kit (26P) with 1.5m cable 1 to 12 stations Multiple connector kit (26P) with 3.0m cable (24 stations) TD0 Terminal block box kit Multiple connector kit (26P) with 5.0m cable

1 to 10 stations (20 stations)

SDA2 Serial kit for PROFIBUS-DP

1 to 8 stations (16 stations)

96

Series 56-VQC

Base-Mounted Type

Plug-in Unit

How to Order Valves

56 - VQC 2 1 0 0
ATEX category 3 Series
2
2-position single (A)(B) 4 2
5 1 3 (R1)(P)(R2)

5
Manual override
Nil: Non-locking
push type (Slotted)

Coil voltage
5
24VDC

4.2

56-VQC2000

Type of actuation
1 A
4-position dual 3-port valve (A) (B) (A) 4 2
5 3 (R1) 1 (R2) (P) N.C N.C 4-position dual 3-port valve (A) (B) (B) 4 2 5 3 (R1) 1 (R2) (P) N.O N.O 4-position dual 3-port valve (A) (B) (C) 4 2 5 (R1) N.C 3 1 (R2) (P) N.O

Function
Nil

B: Locking type
(Slotted)
4.2

Note)

Standard type (1W) External pilot

2-position double (metal) (A)(B) 4 2


5 1 3 (R1)(P)(R2)

Note)

C: Locking type
(Manual)
11mm

2-position double (rubber) (A)(B) 4 2


5 1 3 (R1)(P)(R2) 3-position closed centre (A)(B) 4 2 5 1 3 (R1)(P)(R2) 3-position exhaust centre (A)(B) 4 2 5 1 3 (R1)(P)(R2)

Note)

Seal type
0 1
Metal seal Rubber seal

Note) For rubber seal type only.

D: Slide locking type


(Manual)
OFF ON

Note) ''56-'' solenoid valve should be installed in ''56-VV5QC21'' manifold. Power consumption when starting is 1W, when maintaining 0.35W.

3-position pressure centre (A)(B) 4 2


5 1 3 (R1)(P)(R2)

97

5-Port Solenoid Valve

Series

56-VQC4000
II 3GD EEx nA II T5X T85C IP67
For more details, other specifications, dimensions, see the specific catalogue.

How to Order Manifolds

56 - VV5QC 4 1 08 02 56 - VV5QC 4 1 08 02
Series ATEX category 3
4 56-VQC4000

TD0 N SDA2 N
Nil

M / T F L S Kit
Options
K
None Special wiring specifications (except for double wiring) With name plate (T kit only)

Kit

Manifold model
1
Plug-in unit

Stations
01
1 station

COM.
The maximum number of stations differs depending on the electrical entry (refer to Electrical entry/Cable length).

() COM.

Cylinder port size


C8 C10 C12 CM 02 03 B
With 8 One-touch fitting With 10 One-touch fitting With 12 One-touch fitting Mixed sizes and with port plug 1/4 thread 3/8 thread Bottom port 1/4

Thread type
Nil F T
Rc G NPT

Kit designation/Electrical entry/Cable length

Kit (Multiple connector kit)

Kit (Terminal block box kit)

Kit (Serial output kit)

EX500 series

MD0 MD1 MD2 MD3

Multiple connector kit (26P) without cable Multiple connector kit (26P) with 1.5m cable 1 to 12 stations Multiple connector kit (26P) with 3.0m cable (16 stations) TD0 Terminal block box kit Multiple connector kit (26P) with 5.0m cable

Serial kit for gateway (56-EX500)


1 to 10 stations (16 stations)

SDA2 PROFIBUS-DP

Serial kit for

1 to 8 stations (16 stations)

98

Series 56-VQC

Base-Mounted Type

Plug-in Unit

How to Order Valves

56 - VQC 4 1 0 0
ATEX category 3

5
Manual override
Nil: Non-locking
push type (Slotted)

Series
4 56-VQC4000

Type of actuation
1
2-position single (A)(B) 4 2
5 1 3 (R1)(P)(R2)

B: Locking type
(Slotted)

3-position exhaust center (A)(B) 4 2


5 1 3 (R1)(P)(R2)

Coil voltage
5
24VDC

2-position double (metal) (A)(B) 4 2


5 1 3 (R1)(P)(R2) 2-position double (rubber) (A)(B) 4 2 5 1 3 (R1)(P)(R2)

3-position pressure center (A)(B) 4 2


5 1 3 (R1)(P)(R2) 3-position perfect (A)(B) 4 2 5 1 3 (R1)(P)(R2)

Function
Nil R
Standard type (1W) External pilot

3-position closed centre (A)(B) 4 2


5 1 3 (R1)(P)(R2)

Seal type
0 1
Metal seal Rubber seal

Note) ''56-'' solenoid valve should be installed in ''56-VV5QC41'' manifold. Power consumption when starting is 1W, when maintaining 0.35W.

99

56-VQC1000

Kit (Multiple Connector Kit)

56-VV5QC11
(L4) (L3) L2 1.5

(5.25) L1 P=10.5 28 1.5

65 (12) 13

72

Indicator light

Manual override

93.5

(35)

=2 20

(40)

Power saving unit

4xM4 Mounting holes

D SIDE

STATIONS

U SIDE 2xC8:3(R)EXH.port C8:One-touch fitting for 8 DIN rail clamp screw 18.5 (7.5) 40.5 (12) 62.5

60

Multi-connector cable assembly AXT100-MC26-015:1.5m AXT100-MC26-030:3m AXT100-MC26-050:5m

18

2nxC3,C4,C6,M5<4(A),2(B) Port> C3:One-touch fitting for 3.2 C4:One-touch fitting for 4 C6:One-touch fitting for 6 M5:M5 Threads

20.5 P=10.5 34

2xC8:1(P)SUP.port C8:One-touch fitting for 8

Formulas L1 = 10.5n + 45 L2 = 10.5n + 123 (1~12 stations w/1 power saving unit) L2 = 10.5n + 144 (13~24 stations w/2 power saving unit)

n: Stations (Max. 24 stations)

L L1 L2 L3 L4

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 55.5 66 76.5 87 97.5 108 118.5 129 139.5 150 160.5 171 181.5 192 202.5 213 223.5 234 244.5 255 265.5 276 286.5 297 133.5 144 154.5 165 175.5 186 196.5 207 217.5 228 238.5 249 280.5 291 301.5 312 322.5 333 343.5 354 364.5 375 385.5 396 162.5 175 175 187.5 200 212.5 225 237.5 237.5 250 262.5 275 300 312.5 325 337.5 350 362.5 375 375 387.5 400 412.5 425 173 185.5 185.5 198 210.5 223 235.5 248 248 260.5 273 285.5 310.5 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5

100

7.5 9.5

(5.5)

66 75

S
(12) 13

56-VQC1000

Kit (Serial Transmission Kit) Decentralised Serial wiring

56-VV5QC11 SDA2 Kit (Serial Transmission Kit: 56-EX500)


(L4) (L3) L2 1.5 (5.25) L1 P=10.5

65

21

63.5 21

Indicator light

28 1.5

Manual override

PWR

93.5

COM

(35)

(40)

EX500 series

(5.5)

66

=9

SI unit D SIDE C1(M12) C2(M12)


0

Power saving unit STATIONS


1 2 3 4 5 6 7 8 n

4xM4 Mounting holes U SIDE 2xC8:3(R)EXH.port C8:One-touch fitting for 8

DIN rail clamp screw 62.5

60

=2 (12) (7.5) 2nxC3,C4,C6,M5<4(A),2(B) Port> C3:One-touch fitting for 3.2 C4:One-touch fitting for 4 C6:One-touch fitting for 6 M5:M5 Threads 20.5 P=10.5 34 2xC8:1(P)SUP.port C8:One-touch fitting for 8 Formulas L1 = 10.5n + 45 L2 = 10.5n + 114.5 (1~12 stations w/1 power saving unit) L2 = 10.5n + 135.5 (13~16 stations w/2 power saving unit) n: Stations (Max. 16 stations)

75

L L1 L2 L3 L4

1 55.5 125 150 160.5

2 66 135.5 162.5 173

3 76.5 146 175 185.5

4 87 156.5 187.5 198

5 97.5 167 187.5 198

6 108 177.5 200 210.5

7 118.5 188 212.5 223

8 129 198.5 225 235.5

9 139.5 209 237.5 248

10 150 219.5 250 260.5

11 160.5 230 250 260.5

12 171 240.5 262.5 273

13 181.5 272 300 310.5

7.5

9.5

18.5

14 192 282.5 312.5 323

15 202.5 293 312.5 323

25

40.5

16 213 303.5 325 335.5

101

T
(12) 13

56-VQC1000

Kit (Terminal Block Box Kit)


(L4) (L3) L2 21 1.5

56-VV5QC11
(5.25) L1 P=10.5 Indicator light
U side

124 1

28 1.5

Manual override

(59)

Power saving unit 2xM5 Mounting holes 2xG3/4" Conduit port D SIDE STATIONS
1 2 3 4 5 6 7 8 n

4xM4 Mounting holes U SIDE 2xC8:3(R)EXH.port C8:One-touch fitting for 8

77.7

DIN rail clamp screw 18.7 25 40.5 62.5 20.5 34 2xC8:1(P)SUP.port C8:One-touch fitting for 8 n: Stations (Max. 20 stations)

3 X 12 P 1A
A A A A A A A B B B B B B B B

3 X 12 P 1

45.5

(12) (7.5)

35

2nxC3,C4,C6,M5<4(A),2(B) Port> C3:One-touch fitting for 3.2 C4:One-touch fitting for 4 C6:One-touch fitting for 6 M5:M5 Threads

P=10.5

Formulas L1 = 10.5n + 45 L2 = 10.5n + 175.5 (1~12 stations w/1 power saving unit) L2 = 10.5n + 196.5 (13~20 stations w/2 power saving unit)

L L1 L2 L3 L4

1 2 3 4 5 6 7 55.5 66 76.5 87 97.5 108 118.5 186 196.5 207 217.5 228 238.5 249 212.5 225 237.5 237.5 250 262.5 275 223 235.5 248 248 260.5 273 285.5

8 129 259.5 287.5 298

9 139.5 270 300 310.5

10 150 280.5 300 310.5

11 160.5 291 312.5 323

14 13 15 12 171 181.5 192 202.5 301.5 333 343.5 354 325 362.5 375 375 335.5 373 385.5 385.5

16 213 364.5 387.5 398

17 223.5 375 400 410.5

102

7.7 9.5

19 18 20 234 244.5 255 385.5 396 406.5 412.5 425 437.5 423 435.5 448

(40) (5.5)

(35) 66 75 93.5

126 80

A B A B A B A B A B A B A

D side

M
(12) 13

56-VQC2000

Kit (Multiple Connector Kit)

56-VV5QC21
(L4) (L3) L2 68 76.5 21 1 34.5 L1 Indicator light Manual override P=16 38.5 1

127

(5.5) =3.5 (53.5) 80 105.5 =5.5 4xM5 Mounting holes D SIDE 2xC10:3(R)EXH.port C10:One-touch fitting for 10 DIN rail clamp screw STATIONS
1 2 3 4 5 6 7 8 n

Power saving unit

U SIDE

(35)

18

10

(12) (7.5)

2xC10:1(P)SUP.port C10:One-touch fitting for 10 2nxC4,C6,C8<4(A),2(B) Port> C4:One-touch fitting for 4 C6:One-touch fitting for 6 C8:One-touch fitting for 8

25 P=16 45

Formulas L1 = 16n + 57 L2 = 16n + 131.5 (1~12 stations w/1 power saving unit) L2 = 16n + 152.5 (13~24 stations w/2 power saving unit)

n: Stations (Max. 24 stations)

L L1 L2 L3 L4

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 73 89 105 121 137 153 169 185 201 217 233 249 265 281 297 313 329 345 361 377 393 409 425 441 147.5 163.5 179.5 195.5 211.5 227.5 243.5 259.5 275.5 291.5 307.5 323.5 360.5 376.5 392.5 408.5 424.5 440.5 456.5 472.5 488.5 504.5 520.5 536.5 175 187.5 200 225 237.5 250 275 287.5 300 312.5 337.5 350 387.5 400 412.5 437.5 450 462.5 487.5 500 512.5 525 550 562.5 185.5 198 210.5 235.5 248 260.5 285.5 298 310.5 323 348 360.5 398 410.5 423 448 460.5 473 498 510.5 523 535.5 560.5 573

13.5

25

Multi-connector cable assembly AXT100-MC26-015:1.5m AXT100-MC26-030:3m AXT100-MC26-050:5m

60

49.5

76.5

103

S
(12) 13

56-VQC2000

Kit (Serial Transmission Kit) Decentralised Serial wiring

56-VV5QC21 SDA2 Kit (Serial Transmission Kit: 56-EX500)


(L4) (L3) L2

(5.25) P=16 38.5

76.5 21

59.5 21

34.5

L1 Indicator light Manual override

127

PWR

(53.5)

EX500 series

(5.5)

=3.5

SI unit

Power saving unit

4xM5 Mounting holes D SIDE STATIONS


1 2 3 4 5 6 7 8 n

U SIDE

2xC10:3(R)EXH.port C10:One-touch fitting for 10 C1(M12) C2(M12) DIN rail clamp screw 0 76.5 60 49.5 25 P=16 45 Formulas L1 = 16n + 57 L2 = 16n + 123 (1~12 stations w/1 power saving unit) L2 = 16n + 144 (13~16 stations w/2 power saving unit) n: Stations (Max. 16 stations) 1 25 10 30 2xC10:1(P)SUP.port C10:One-touch fitting for 10 2nxC4,C6,C8<4(A),2(B) Port> C4:One-touch fitting for 4 C6:One-touch fitting for 6 C8:One-touch fitting for 8

L L1 L2 L3 L4

1 73 139 162.5 173

2 89 155 175 185.5

3 105 171 200 210.5

(12)

4 121 187 212.5 223

(7.5)

5 137 203 225 235.5

6 153 219 250 260.5

7 169 235 262.5 273

8 185 251 275 285.5

9 201 267 287.5 298

10 217 283 312.5 323

11 233 299 325 335.5

12 249 315 337.5 348

13 265 352 375 385.5

14 281 368 387.5 398

15 297 384 412.5 423

13.5

With signal cut block, L4 is obtained by adding approximately 30 mm to L2.

104

=5.5

(35) 80 105.5

COM

16 313 400 425 435.5

56-VV5QC21
120 (L4) (L3) L2 1 (5.25) L1 P=16 38.5

56-VQC2000

Kit (Terminal Block Box Kit)

76.5 (12) 13

Indicator light Manual override

U side

D side

132.5 80

(59)

(5.5)

Power saving unit

4xM5 Mounting holes D SIDE STATIONS


1 2 3 4 5 6 7 8 n

U SIDE

2xG3/4 Conduit port

2xC10:3(R)EXH.port C10:One-touch fitting for 10

DIN rail clamp screw 77.5

45.5 25 10

(12) (7.5)

2xC10:1(P)SUP.port C10:One-touch fitting for 10 2nxC4,C6,C8<4(A),2(B) Port> C4:One-touch fitting for 4 C6:One-touch fitting for 6 C8:One-touch fitting for 8

25 P=16 45

Formulas L1 = 16n + 45 L2 = 16n + 184 (1~12 stations w/1 power saving unit) L2 = 16n + 205 (13~20 stations w/2 power saving unit)

n: Stations (Max. 20 stations)

L L1 L2 L3 L4

1 2 3 73 89 105 200 216 232 225 237.5 262.5 235.5 248 273

4 121 248 275 285.5

5 137 264 287.5 298

6 7 153 169 280 296 300 325 310.5 335.5

8 185 312 337.5 348

9 201 328 350 360.5

10 217 344 375 385.5

11 233 360 387.5 398

12 13 249 265 376 413 400 437.5 410.5 448

14 281 429 450 460.5

15 297 445 475 485.5

16 313 461 487.5 498

17 329 477 500 510.5

18 19 345 361 493 509 512.5 537.5 523 548

13.5

30 49.5

=5.5

(35) 80 105.5

20 377 525 550 560.5

105

56-VQC4000

Kit (Multiple Connector Kit)

56-VV5QC41
L2 69 21 L1 Indicator light Manual override (6.5) P=25 65.5

9 143 74.5
B B B B B

Power saving unit

D SIDE

STATIONS

U SIDE 2xRc3/4 3(R)EXH.port 2xRc1/2 1(P)SUP.port

Multi-connector cable assembly AXT100-MC26-015:1.5m AXT100-MC26-030:3m AXT100-MC26-050:5m

SMC

SMC

SMC

SMC

SMC

SMC

SMC

60

42.7

15.7

(6.5)

21.5 38.7

2xRc1/8 Pilot EXH.port 2xRc1/8 External pilot port P=25

21.5 27 31 38.7 65.5

11.5

(6.5)

2n-Rc1/4,3/8,C8,C10,C12<4(A),2(B)Port> Rc1/4:Rc1/4 Thread Rc3/8:Rc3/8 Thread C8 :One-touch fitting for 8 C10:One-touch fitting for 10 C12:One-touch fitting for 12

Formulas L1 = 25n + 106 L2 = 25n + 181.5 (1~12 stations w/1 power saving unit) L2 = 25n + 202.5 (13~16 stations w/2 power saving unit)

n: Stations (Max. 16 stations)

L L1 L2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 131 156 181 206 231 256 281 306 331 356 381 406 431 456 481 506 206.5 231.5 256.5 281.5 306.5 331.5 356.5 381.5 406.5 431.5 456.5 481.5 527.5 552.5 577.5 602.5

106

12 20.5 43.5

18

77.5 95.5 101

10

163

A A

A A

A A

A A

A A

A A

A A

56-VQC4000

Kit (Serial Transmission Kit) Decentralised Serial wiring

56-VV5QC41 SDA2 Kit (Serial Transmission Kit: 56-EX500)


60.5 21 21 L1 Indicator light Manual override L2 6.5

P=25

65.5

PWR COM

EX500 series

SI unit (101) D SIDE Power saving unit

STATIONS

U SIDE 2xRc3/4 3(R)EXH.port 2xRc1/2 1(P)SUP.port

SMC

SMC

SMC

SMC

SMC

SMC

SMC

M12
0
2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B

60 42.7 15.7 12

M12

(6.5)

21.5 38.7

2xRc1/8 Pilot EXH.port 2xRc1/8 External pilot port P=25

21.4 27 31 38.7 65.5

11.5

(6.5)

2n-Rc1/4,3/8,C8,C10,C12<4(A),2(B)Port> Rc1/4:Rc1/4 Thread Rc3/8:Rc3/8 Thread C8 :One-touch fitting for 8 C10:One-touch fitting for 10 C12:One-touch fitting for 12

Formulas L1 = 25n + 106 L2 = 25n + 173 (1~12 stations w/1 power saving unit) L2 = 25n + 194 (13~16 stations w/2 power saving unit)

n: Stations (Max. 16 stations)

L L1 L2

1 131 198

2 156 223

3 181 248

4 206 273

5 231 298

6 256 323

7 281 348

8 306 373

9 331 398

10 356 423

11 381 448

12 406 473

13 431 519

14 456 544

15 481 569

12 20.5 43.5

77.5 95.5 101

10

143 163

9
A A A A A A A

16 506 594

107

56-VQC4000

Kit (Terminal Block Box Kit)

56-VV5QC41
L2 Indicator light 6.5

100.5

L1

P=25

65.5

Manual override
A
B

80

34.5

(101)

Power saving unit

D SIDE

STATIONS

U SIDE

2xG3/4" Conduit port


SMC SMC SMC SMC SMC SMC SMC

2xRc3/4 3(R)EXH.port 2xRc1/2 1(P)SUP.port

77.5 45.5 42.7 15.7 12

11.5

(6.5)

21.5 38.7

2xRc1/8 Pilot EXH.port 2xRc1/8 External pilot port P=25

21.4 27 31 38.7 65.5

(6.5)

2n-Rc1/4,3/8,C8,C10,C12<4(A),2(B)Port> Rc1/4:Rc1/4 Thread Rc3/8:Rc3/8 Thread C8 :One-touch fitting for 8 C10:One-touch fitting for 10 C12:One-touch fitting for 12

Formulas L1 = 25n + 106 L2 = 25n + 213 (1~12 stations w/1 power saving unit) L2 = 25n + 234 (13~16 stations w/2 power saving unit)

n: Stations (Max. 16 stations)

L L1 L2

1 131 238

2 156 263

3 181 288

4 206 313

5 231 338

6 256 363

7 281 388

8 306 413

9 331 438

10 356 463

11 381 488

12 406 513

13 431 559

14 456 584

12 20.5 43.5

15 481 609

108

77.5 95.5 101

10

143 163

9
U side
A A A A A A A

D side

16 506 634

For Air/Single Unit

Direct Operated 2 Port Solenoid Valve

Series
AC DC

56-VX21/22/23
How to Order (Single Unit)

For more details, other specifications, dimensions, see the specific catalogue.

56-VX 21 2 0 56-VX 21 2 0
Model Orifice size
Refer to the table (1) shown below for availability.

01 01

1 G R1 5 G 1
Bracket
-

ATEX category 3
Refer to the table (1) shown below for availability.

None With bracket

Valve/Body configuration
0 2
N.C. / Single unit N.O. / Single unit
Refer to the table (2) shown below for availability.

Port size
Refer to the table (1) shown below for availability.

Built-in full-wave rectifier type

Brackets VX021N-12A and VX022N-12A are packaged together with the valve. Refer to the table (4) if a bracket is ordered separately.

Solenoid valve option Suffix


Oil-free spec. -

Electrical entry Thread type


T F N
Rc NPTF G NPT

G - Grommet GS- With grommet surge


voltage suppressor

C- Conduit

Select "-" because the solenoid valve options V, M are the oil-free treatment.

T - With conduit terminal TS - With conduit terminal and TL - With conduit terminal TZ - With conduit
and light terminal, surge voltage suppressor and light surge voltage suppressor

Connector D - DIN terminal DS - DIN terminal with surge

Rated voltage
1 2 3 4 5
100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC

6 7 8 J

12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz

DL - DIN terminal with light DZ - DIN terminal with

voltage suppressor

surge voltage suppressor and light DO - For DIN terminal (without connector, gasket is included.) DIN type is available with Class B coils only.

Refer to the table (3) shown below for availability.

Table (1) Port/Orifice Size Port Size Normally Closed (N.C.)


Solenoid valve (Port size) Model Orifice symbol (Diameter)

Refer to the table (3) for the available combinations between each electrical option (S, L, Z) and the rated voltage. Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil, as standard.

Table (3) Rated Voltage Electrical Option


Rated voltage AC/ DC Class B

VX21 01 (1/8) 02 (1/4)

VX22

1 2 3 4 5 6 VX23 (2 mm) (3 mm) (4.5 mm) (6 mm) (8 mm) (10 mm)

L
With light

Z
With light and surge voltage suppressor

Port no. (Port size)

02 (1/4) 02 (1/4) 03 (3/8) 03 (3/8) 04 (1/2) 04 (1/2)

AC

Normally Open (N.O.)


Solenoid valve (Port size) Model Orifice symbol (Diameter)

VX21 01 (1/8) 02 (1/4)

VX22

VX23

(2 mm)

(3 mm) (4.5 mm) (6 mm)

DC

With surge Voltage voltage Voltage symbol suppressor 1 100 V 2 200 V 3 110 V 4 220 V 7 240 V 8 48 V J 230 V 5 24 V 6 12 V

Port no. (Port size)

02 (1/4) 03 (3/8)

02 (1/4) 03 (3/8)

Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil, as standard.

Table (4) Bracket Part No.


Model Note Part no. VX021N-12A VX022N-12A VX023N-12A-L

Table (2) Solenoid Valve Option


Option symbol Nil Seal material NBR FKM Body material Brass (C37) Stainless steel Brass (C37) Stainless steel Coil insulation type B

VX21 2 0 VX22 3 0 VX23 3 0


4 2 4 VX22 5 0 6 VX23 5 0 6 3 2

G V M

Non-leak (106 Pam3/sec), Oil-free, Medium vacuum (0.1 Pa.abs)

Please consider the VCA series when using air because it was specifically designed for it. (The VCA series is limited to air to improve its function and service life.)

When the fluid is air.


When you operate the VX series (AC spec.) with air, select the built-in full-wave rectifier type. The special construction of the armature reduces abrasion, resulting in a longer service life. Reduced buzz noise

109

For Air/Manifold

Direct Operated 2 Port Solenoid Valve

Series
AC DC

56-VX21/22/23
Suffix

For more details, other specifications, dimensions, see the specific catalogue.

How to Order (Solenoid Valve for Manifold)

56- VX 21 2 1 56- VX 21 2 1
Model
-

00 1 G R 1 00 5 G 1
Built-in full-wave rectifier type
Z
Oil-free spec.
Select "-" because the solenoid valve options V, R are the oil-free treatment.

ATEX category 3
Refer to the table (1) shown below for availability.

Orifice size
Refer to the table (1) shown below for availability.

Electrical entry
C- Conduit

Valve/Body configuration
1 3
N.C. (For manifold) N.O. (For manifold)

G - Grommet GS- With grommet surge


voltage suppressor

Solenoid valve option Rated voltage


T - With conduit terminal TS - With conduit terminal and TL - With conduit
surge voltage suppressor terminal and light TZ - With conduit terminal, surge voltage suppressor and light

Refer to the table (2) shown below for availability.

D - DIN terminal DS - DIN terminal with surge voltage DL - DIN terminal with light DZ - DIN terminal with surge
suppressor

1 2 3 4 5

100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC

6 7 8 J

12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz

Refer to the table (3) shown below for availability.

voltage suppressor and light DO - For DIN terminal (without connector, gasket is included.) DIN type is available with Class B coils only.

How to Order Manifold Bases

VVX21 VVX22 1 VVX23


Port size (Out port)
1 2
1/8 1/4

Refer to the table (3) for the available combinations between each electrical option (S, L, Z) and the the rated voltage. Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class coil B, as standard.

07 1
Number of manifolds
02
2 stations 10 stations

Table (1) Port/Orifice Size


Solenoid valve Orifice symbol (Diameter) (2 mm)

(3 mm)

(4.5 mm)

(6 mm)

VX21 VX22 VX23

Thread type
-

10

Table (2) Solenoid Valve Option


Option Body, Base symbol material Seal material NBR Aluminum FKM B
Coil insulation type

All IN ports are 3/8.

T F N

Rc NPTF G NPT

Suffix
-

Note Non-leak, Medium vacuum, Oil-free Non-leak, Copper-free, Oil-free Note)

Oil-free spec.

V R

Manifold base `Blanking plate part no. For VX21: VX011-001 For VX22/23: VX011-006

Base
-

Note) The nuts (non-wetted parts), are nickel-plated brass (C37).

Common SUP type Individual SUP type

When the fluid is air.


When you operate the VX series (AC spec.) with air, select the built-in full-wave rectifier type. The special construction of the armature reduces abrasion, resulting in a longer service life. Reduced buzz noise Best suited for medical equipment, low-noise environments, etc.

Seal material
-

NBR FKM

How to Order Manifold Assemblies (Example)


Enter the valve and blanking plate to be mounted under the manifold base part number.
Example VVX211-05-1 ........ 1 set VX2111-00-1G1 ..... 4 sets VX011-001 ........... 1 set
Station
1 2 3 4

Table (3) Rated Voltage Electrical Option


Rated voltage AC/ DC Class B

L
With light

Z
With light and surge voltage suppressor

is the symbol for mounting. Add an in front of the part numbers for solenoid valves, etc. to be mounted.
5 n

Enter the products part number in order, counting from the 1st station on the left in the manifold arrangement, when viewed with the individual ports in front.

AC

DC

With surge Voltage Voltage voltage symbol suppressor 1 100 V 2 200 V 3 110 V 4 220 V 7 240 V 8 48 V J 230 V 5 24 V 6 12 V

Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil, as standard.

110

For Water/Single Unit

Direct Operated 2 Port Solenoid Valve

Series
AC DC
Model
Refer to the table (1) shown below for availability.

56-VX21/22/23
How to Order (Single Unit)

For more details, other specifications, dimensions, see the specific catalogue.

56-VX 21 2 0 56-VX 21 2 0
Orifice size
Refer to the table (1) shown below for availability.

01 01

1 G R1 5 G 1
Bracket
-

ATEX category 3
B

None With bracket

Valve/Body configuration
0 2
N.C. / Single unit N.O. / Single unit

Full-wave rectifier Port size


Refer to the table (1) shown below for availability.

None Built-in full-wave rectifier type (Class B only)

Brackets VX021N-12A and VX022N-12A are packaged together with the valve. Refer to the table (4) if a bracket is ordered separately.

Solenoid valve option


Refer to the table (2) shown below for availability.

Thread type
-

Suffix
-

Oil-free spec.

T F N

Rc NPTF G NPT

Electrical entry
G - Grommet GS- With grommet surge
voltage suppressor

C- Conduit

Select "-" because the solenoid valve option L is the oil-free treatment. AC/Class B oil-free coils are applicable to the full-wave rectifier type only. Select the full-wave rectifier type.

T - With conduit terminal TS - With conduit terminal and

Rated voltage
6 7 8 J
12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz

1 2 3 4 5

100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC

TL - With conduit terminal TZ - With conduit


and light terminal, surge voltage suppressor and light

surge voltage suppressor

Connector D - DIN terminal DS - DIN terminal with surge

DL - DIN terminal with light DZ - DIN terminal with

voltage suppressor

Refer to the table (3) shown below for availability.

surge voltage suppressor and light DO - For DIN terminal (without connector, gasket is included.) DIN type is available with Class B coils only.

Table (1) Port/Orifice Size Port Size Normally Closed (N.C.)


Solenoid valve (Port size) Model Orifice symbol (Diameter)

Refer to the table (3) for the available combinations between each electrical option (S, L, Z) and the rated voltage. Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil (Built-in full-wave rectifier type), as standard.

Table (2) Solenoid Valve Option


5 6
Option symbol Seal Body/Shading Coil Note material coil material insulation type Brass (C37)/Cu NBR B Stainless steel/Ag Brass (C37)/Cu Heated water EPDM H (AC only) Stainless steel/Ag FKM Stainless steel/Ag B High corrosive, Oil-free

VX21 01 (1/8) 02 (1/4)

VX22

VX23 (2 mm) (3 mm) (4.5 mm) (6 mm) (8 mm) (10 mm)

Port no. (Port size)

02 (1/4) 02 (1/4) 03 (3/8) 03 (3/8) 04 (1/2) 04 (1/2)

G E P L

Normally Open (N.O.)


Solenoid valve (Port size) Model Orifice symbol (Diameter)

Table (4) Bracket Part No.


4
Model VX21 2 0 VX22 3 0
3 2 4 2 1

VX21 01 (1/8) 02 (1/4)

VX22

VX23

(2 mm)

(3 mm) (4.5 mm) (6 mm)

Part no. VX021N-12A VX022N-12A VX023N-12A-L

Port no. (Port size)

02 (1/4) 03 (3/8)

02 (1/4) 03 (3/8)

VX23 3 0
4 VX22 5 0 6 VX23 5 0 6

Table (3) Rated Voltage Electrical Option


Rated voltage AC/ DC Class B Class H

L
With light

L
With light

Z
With light/ surge voltage suppressor

AC

DC

With surge Voltage Voltage voltage symbol suppressor 1 100 V 2 200 V 3 110 V 4 220 V 7 240 V 8 48 V J 230 V 5 24 V 6 12 V

With light/ With surge surge voltage voltage suppressor suppressor

DC spec. is not available.

Option S, Z are not available as surge voltage suppressor is integrated into the AC/Class B coil (Built-in full-wave rectifier type), as standard.

111

For Water/Manifold

Direct Operated 2 Port Solenoid Valve

Series
ATEX category 3

56-VX21/22/23
1 G R1 5 G 1

For more details, other specifications, dimensions, see the specific catalogue.

How to Order (Solenoid Valve for Manifold)


Electrical entry
G - Grommet C- Conduit GS-With grommet surge
voltage suppressor

AC DC

56- VX 21 2 1 56- VX 21 2 1
Model Orifice size
Refer to the table (1) shown below for availability.

Refer to the table (1) shown below for availability.

Valve/Body configuration
1 3
N.C. (For manifold) N.O. (For manifold)

T - With conduit TS - With conduit


terminal

Solenoid valve option


Refer to the table (2)-(1) shown below for availability.

Suffix
-

Rated voltage
1 2 3 4 5
100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC

Oil-free spec.

Select "-" because the solenoid valve option L is the oil-free treatment. AC/Class B oil-free coils are applicable to the fullwave rectifier type only. Select the full-wave rectifier type.

6 7 8 J

12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz

surge voltage suppressor DL - DIN terminal with terminal and surge light voltage suppressor DZ - DIN terminal with TL - With conduit surge voltage terminal and light suppressor and TZ - With conduit light terminal, surge DO - For DIN terminal voltage suppressor (without connector, and light gasket is included.)

D - DIN terminal DS - DIN terminal with

Refer to the table (3) shown below for availability.

Full-wave rectifier
Nil None Built-in full-wave rectifier type (Class B only) DIN type is available with Class B coils only. Refer to the table (3) for the available combinations between each electrical option (S, L, Z) and the rated voltage.
Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil (Built-in full-wave rectifier type), as standard.

How to Order Manifold Bases

VVX21 VVX22 1 VVX23


Port size (OUT port)
1 2
1/8 1/4 -

C
Thread type
T F N
Rc NPTF G NPT

07 1
Number of manifolds
02 10
2 stations 10 stations Solenoid valve (2 mm)

Table (1) Port/Orifice Size


Orifice symbol (Diameter)

(2 mm)

(4.5 mm)

(6 mm)

Suffix
-

All IN ports are 3/8.

Oil-free spec.

VX21 VX22 VX23

Manifold base
Blanking

Base, Seal material


Refer to the table (2)-(2).

Table (2) Solenoid Valve Option


Solenoid Base, Seal Body, Base/ valve option material Shading symbol (1) symbol (2) coil material Seal material NBR EPDM FKM Coil insulation type B H B Note Heated water (AC only) High corrosive, Oil-free

plate part no.

For VX21: VVX21-3A For VX22: VVX22-3A For VX23: VVX23-3A Seal material
NBR FKM EPDM

G E P L

C S CE SE SF

Brass (C37)/Cu Stainless steel/Ag Brass (C37)/Cu Stainless steel/Ag Stainless steel/Ag

F E

Table (3) Rated Voltage Electrical Option


Rated voltage AC/ DC

Class B

Class H

How to Order Manifold Assemblies (Example)


Enter the valve and blanking plate to be mounted under the manifold base part number.
Example VVX211C-05-1 ...... 1 set VX2111-1G1 ........ 4 sets VVX21-3A ........... 1 set
Station 1 2 3 4

L
With light

L
With light

Z
With light/ surge voltage suppressor

is the symbol for mounting. Add an in front of the part numbers for solenoid valves, etc. to be mounted.
5 n

AC

Enter the products part number in order, counting from the 1st station on the left in the manifold arrangement, when viewed with the individual ports in front.

DC

With surge Voltage Voltage voltage symbol suppressor 1 100 V 2 200 V 3 110 V 4 220 V 7 240 V 8 48 V J 230 V 5 24 V 6 12 V

With light/ With surge surge voltage voltage suppressor suppressor

DC spec. is not available.

Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil (Built-in full-wave rectifier type), as a standard.

112

For Oil/Single Unit

Direct Operated 2 Port Solenoid Valve

Series
ATEX category 3

56-VX21/22/23
How to Order (Single Unit)

For more details, other specifications, dimensions, see the specific catalogue.

AC DC

56-VX 21 2 0 A 56-VX 21 2 0 A
Model

01 01

1 G R1 5 G 1
Bracket
-

Valve/Body configuration
0 2
N.C. / Single unit N.O. / Single unit

Refer to the table (1) Orifice size shown below for availability. Refer to the table (1) shown below for availability.

None With bracket

Full-wave rectifier
Nil None Built-in full-wave rectifier type (Class B only)

Port size
Refer to the table (1) shown below for availability.

Solenoid valve option


Refer to the table (2) shown below for availability.

Brackets VX021N-12A and VX022N-12A are together with the valve. Refer to the table (4) if a bracket is ordered separately.

Suffix
Oil-free spec.

Thread type
-

AC/Class is oil-free coils are applicable to the full-wave rectifier type only. Select the full-wave rectifier type.

T F N

Rc NPTF G NPT

Electrical entry
G - Grommet GS- With grommet surge
voltage suppressor

C- Conduit

Rated voltage
1 2 3 4 5
100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC

6 7 8 J

12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz

T - With conduit terminal TS - With conduit terminal and TL - With conduit terminal TZ - With conduit
and light terminal, surge voltage suppressor and light surge voltage suppressor

D - DIN terminal Connector DS - DIN terminal with surge DL - DIN terminal with DZ - DIN terminal with
light voltage suppressor

Refer to the table (3) shown below for availability.

surge voltage suppressor and light DO -For DIN terminal (without connector, gasket is included.) DIN type is available with Class B coils only.

Table (1) Port/Orifice Size Normally Closed (N.C.)


Solenoid valve (Port size) Model Orifice symbol (Diameter)

Refer to the table (3) for the available combinations between each electrical option (S, L, Z) and the rated voltage. Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil (built-in full-wave rectifier type), as standard.

VX21 01 (1/8) 02 (1/4)

VX22

3 4 5 6 VX23 (2 mm) (3 mm) (4.5 mm) (6 mm) (8 mm) (10 mm)

Table (2) Solenoid Valve Option


Option symbol Seal material FKM Body/Shading Coil coil material insulation type Brass (C37)/Cu Stainless steel/Ag Brass (C37)/Cu Stainless steel/Ag B H

Port no. (Port size)

02 (1/4) 02 (1/4) 03 (3/8) 03 (3/8) 04 (1/2) 04 (1/2)

A H D N
Orifice symbol (Diameter)

Normally Open (N.O.)


Solenoid valve (Port size) Model Port no. (Port size)

Additives contained in oil are different depending on the type and manufacturer, therefore the durability of the seal materials may vary. For details, please consult with SMC.

VX21 01 (1/8) 02 (1/4)

VX22

VX23

(2 mm)

(3 mm) (4.5 mm) (6 mm)

Table (4) Bracket Part No.


Model Part no. VX021N-12A VX022N-12A VX023N-12A-L VX21 2 0 VX22 3 0 VX23 3 0
4 2 4 VX22 5 0 6 VX23 5 0 6 3 2 1

02 (1/4) 03 (3/8)

02 (1/4) 03 (3/8)

Table (3) Rated Voltage Electrical Option


Rated voltage AC/ DC Class B Class H

L
With light

L
With light

Z
With light/ surge voltage suppressor

AC

DC

With surge Voltage Voltage voltage symbol suppressor 1 100 V 2 200 V 3 110 V 4 220 V 7 240 V 8 48 V J 230 V 5 24 V 6 12 V

With light/ With surge surge voltage voltage suppressor suppressor

DC spec. is not available.

Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil, (built-in full-wave rectifier type), as a standard.

113

For Oil/Manifold

Direct Operated 2 Port Solenoid Valve

Series
ATEX category 3

56-VX21/22/23
1 GR1 5 G 1

For more details, other specifications, dimensions, see the specific catalogue.

How to Order (Solenoid Valve for Manifold)


Electrical entry
G - Grommet C- Conduit GS-With grommet surge
voltage suppressor

AC DC

Model

56- VX 21 2 1 A 56- VX 21 2 1 A
Orifice size
Refer to the table (1) shown below for availability.

Refer to the table (1) shown below for availability.

Valve/Body configuration
1 3
N.C. (For manifold) N.O. (For manifold)

T - With conduit

Solenoid valve option


Refer to the table (2)-(1) shown below for availability.

Suffix
-

Rated voltage
1 2 3 4 5
100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC

Oil-free spec.

AC/Class B oil-free coils are applicable to the fullwave rectifier type only. Select the full-wave rectifier type.

6 7 8 J

12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz

surge voltage terminal suppressor TS - With conduit DL - DIN terminal with terminal and surge light voltage suppressor DZ - DIN terminal with TL - With conduit surge voltage terminal and light suppressor and TZ - With conduit light terminal, surge DO - For DIN terminal voltage suppressor (without connector, and light gasket is included.)

D - DIN terminal DS - DIN terminal with

Refer to the table (3) shown below for availability.

Full-wave rectifier
None Built-in full-wave rectifier type (Class B only) DIN type is available with Class B coils only. Refer to the table (1) for the available combinations between each electrical option (S, L, Z) and the rated voltage.
Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil (Built-in full-wave rectifier type), as standard.

How to Order Manifold Bases

VVX21 VVX22 1 VVX23


Port size (OUT port)
1 2
1/8 1/4

CF

07 1
Number of manifolds
02 10
2 stations 10 stations

Table (1) Port/Orifice Size


Solenoid valve Orifice symbol (Diameter) (2 mm)

(3 mm)

(4.5 mm)

(6 mm)

Thread type
-

VX21 VX22 VX23

All IN ports are 3/8.

T F N

Rc NPTF G NPT

Suffix
-

Oil-free spec.

Table (2) Solenoid Valve Option


Solenoid Base, Seal Body, Base/ valve option material Shading symbol (1) symbol (2) coil material Seal material Coil insulation type B FKM H AC only Note

Base, Seal material


Refer to the table (2)-(2).

Manifold base
Blanking

plate part no.

A H D N

CF SF CF SF

Brass (C37)/Cu Stainless steel/Ag Brass (C37)/Cu Stainless steel/Ag

For VX21: VVX21-3A-F For VX22: VVX22-3A-F For VX23: VVX23-3A-F Seal material: FKM How to Order Manifold Assemblies (Example)
Enter the valve and blanking plate to be mounted under the manifold base part number.
Example VVX211CF-05-1 ..... 1 set VX2111A-1G1 ....... 4 sets VVX21-3A-F ......... 1 set
Station 1 2 3 4

Additives contained in oil are different depending on the type and manufacturer, therefore the durability of the seal materials may vary. For details, please consult with SMC.

Table (3) Rated Voltage Electrical Entry Electrical Option


Rated voltage AC/ DC Class B Class H

L
With light

L
With light

Z
With light/ surge voltage suppressor

is the symbol for mounting. Add an in front of the part numbers for solenoid valves, etc. to be mounted.
5 n

AC

Enter the products part number in order, counting from the 1st station on the left in the manifold arrangement, when viewed with the individual ports in front.

DC

With surge Voltage Voltage voltage symbol suppressor 1 100 V 2 200 V 3 110 V 4 220 V 7 240 V 8 48 V J 230 V 5 24 V 6 12 V

With light/ With surge surge voltage voltage suppressor suppressor

DC spec. is not available.

Option S, Z are not available as a surge voltage suppressor is integrated into the AC/Class B coil (Built-in full-wave rectifier type), as a standard.

114

For Steam/Single Unit

Direct Operated 2 Port Solenoid Valve

Series
ATEX category 3

56-VX21/22/23
How to Order (Single Unit)

For more details, other specifications, dimensions, see the specific catalogue.

AC
Model
Refer to the table (1) shown below for availability.

56- VX 21 2 0 S
Solenoid valve option
Refer to the table (2) shown below for availability.

01

1 G1
Bracket
-

Orifice size
Refer to the table (1) shown below for availability.

None With bracket

Valve/Body configuration
0 2
N.C. / Single unit N.O. / Single unit

Port size
Refer to the table (1) shown below for availability.

Brackets VX021N-12A and VX022N-12A are packaged together with the valve. Refer to the table (4) if a bracket is ordered separately.

Thread type Suffix


Oil-free spec.

T F N

Rc NPTF G NPT

Electrical entry
G - Grommet GS- With grommet surge
voltage suppressor

C- Conduit

Rated voltage
1 2 3 4
100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz

7 8 J

240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz

T - With conduit terminal TS - With conduit terminal and TL - With conduit terminal TZ - With conduit
and light terminal, surge voltage suppressor and light surge voltage suppressor

Refer to the table (3) shown below for availability.

Refer to the table (3) for the available combinations between each electrical option (S, L, Z) and the rated voltage.

Table (1) Port/Orifice Size Normally Closed (N.C.)


Solenoid valve (Port size) Model Orifice symbol (Diameter)

Table (3) Rated Voltage Electrical Option


1 2 3 4 5 6
Rated voltage
AC/ DC

Class H

VX21 01 (1/8) 02 (1/4)

VX22

VX23 (2 mm) (3 mm) (4.5 mm) (6 mm) (8 mm) (10 mm)

Port no. (Port size)

02 (1/4) 02 (1/4) 03 (3/8) 03 (3/8) 04 (1/2) 04 (1/2)

(VX22) AC

Normally Open (N.O.)


Solenoid valve (Port size) Model Orifice symbol (Diameter)

VX21 01 (1/8) 02 (1/4)

VX22

VX23

(2 mm)

(3 mm) (4.5 mm) (6 mm)

DC

With light/ With surge With surge voltage Voltage Voltage voltage light symbol suppressor suppressor 1 100 V 2 200 V 3 110 V 4 220 V 7 240 V 8 48 V J 230 V 5 24 V DC spec. is not available. 6 12 V

Port no. (Port size)

02 (1/4) 03 (3/8)

02 (1/4) 03 (3/8)

Table (4) Bracket Part No.


Model VX21 2 0
Coil insulation type H
1 3 2 4 2

Part no. VX021N-12A VX022N-12A VX023N-12A-L

Table (2) Solenoid Valve Option


Option symbol Seal material PTFE

S Q

Body/Shading coil material Brass (C37)/Cu Stainless steel/Ag

VX22 3 0 VX23 3 0
4 VX22 5 0 6 VX23 5 0 6

Solenoid coil: AC/Class H only

115

For Steam/Manifold

Direct Operated 2 Port Solenoid Valve

Series
ATEX category 3

56-VX21/22/23
1 G1
Orifice size

For more details, other specifications, dimensions, see the specific catalogue.

How to Order (Solenoid Valve for Manifold)

AC
Model
Refer to the table (1) shown below for availability.

56- VX 21 2 3 S
Refer to the table (1) shown below for availability.

Electrical entry
G - Grommet C- Conduit GS-With grommet surge
voltage suppressor

Valve type
1 3
N.C. N.O.

Solenoid valve option


Refer to the table (2)-(1) shown below for availability.

T - With conduit terminal TS - With conduit terminal and

Rated voltage Suffix


Oil-free spec.

TL - With conduit

surge voltage suppressor terminal and light

1 2 3 4

100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz

7 8 J

240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz

TZ - With conduit terminal,


surge voltage suppressor and light Refer to the table (3) for the available combinations between each electrical option (S, L, Z) and the rated voltage.

Refer to the table (3) shown below for availability.

How to Order Manifold Bases

Table (1) Port/Orifice Size


Solenoid valve Orifice symbol (Diameter) (2 mm)

VVX21 VVX22 1 VVX23


Port size (OUT port)
1 2
1/8 1/4 -

CP
Thread type
T F N
Rc NPTF G NPT

07 1
Number of manifolds
02 10
2 stations 10 stations

(3 mm) (N.O.)

(4.5 mm)

(6 mm)

VX21 VX22 VX23

Table (2) Solenoid Valve Option


Solenoid valve option symbol (1) Base, Seal material symbol (2) Body, Base/ Shading coil material Brass (C37)/Cu Stainless steel/Ag Seal material PTFE Coil insulation type H

Suffix
-

All IN ports are 3/8.

Oil-free spec.

S Q

CP SP

Manifold base
Blanking

Base, Seal material


Refer to the table (2)-(2).

plate part no.

Table (3) Rated Voltage Electrical Option


Rated voltage AC/ DC Class H

For VX21: VVX21-3A-P For VX22: VVX22-3A-P For VX23: VVX23-3A-P Seal material: PTFE How to Order Manifold Assemblies (Example)
Enter the valve and blanking plate to be mounted under the manifold base part number.
Example VVX211CP-05-1..... 1 set VX2111S-1G1 ....... 4 sets VVX21-3A-P ......... 1 set
Station 1 2 3 4

AC

is the symbol for mounting. Add an in front of the part numbers for solenoid valves, etc. to be mounted.
5 n

DC

With surge With light/ With surge voltage Voltage Voltage voltage light symbol suppressor suppressor 1 100 V 2 200 V 3 110 V 4 220 V 7 240 V 8 48 V J 230 V 5 24 V DC spec. is not available. 6 12 V

Enter the products part number in order, counting from the 1st station on the left in the manifold arrangement, when viewed with the individual ports in front.

116

Series 56-VX21/22/23
For Air, Water, Oil, Steam

Dimensions: Single Unit/Body Material: Brass, Stainless Steel


Normally closed (N.C.): 56-VX210/56-VX220/56-VX230 Normally open (N.O.): 56-VX212/56-VX222/56-VX232 Grommet: G
M

Conduit: C
25

2-J, thread depth K 300

2-J, thread depth K

280

G1/2

R C (C)

25

Width across flats H

Width across flats H

2-P Port size

2-P Port size

DIN terminal: D

Conduit terminal: T

2-J, thread depth K G1/2 Cable 6 to 12 G1/2

2-J, thread depth K

Q S

F D

D Q2 F
34

25

Width across flats H

Width across flats H

R C

S2 B
(mm) Bracket mounting

2-P Port size

2-P Port size

Model N.C. N.O.

Orifice size

Port size

A
18 22 30 22 30

B
40 45 50 45 50

C
Note 1)

D
30

H J

K
6 8 8 8 8

M
12.8 19 23 19 23 (mm) Electrical entry (Built-in full-wave rectifier type) Note 2) Grommet Conduit DIN terminal Conduit terminal

VX210 VX212 2, 3, 4.5 1/8, 1/4 VX220 VX222 3, 4.5, 6 1/4, 3/8 8, 10 1/4, 3/8, 1/2 VX220 VX230 VX232 3, 4.5, 6 1/4, 3/8 8, 10 1/4, 3/8, 1/2 VX230

68 (76) 78 (86) 85 85.5 (93) 92

9 19.5 27 10.5 35 22.5 32 14 10.5 25 36 40 14

M4 M5 M5 M5 M5

Model N.C. N.O.

Q R VX210 VX212 2, 3, 4.5 1/8, 1/4 19.5 50 60 VX220 VX222 3, 4.5, 6 1/4, 3/8 22.5 8, 10 1/4, 3/8, 1/2 63 VX220 66 VX230 VX232 3, 4.5, 6 1/4, 3/8 25.5 8, 10 1/4, 3/8, 1/2 69 VX230

Orifice size

Port size

Grommet

Electrical entry Note 2) Conduit DIN terminal Conduit terminal

R
46 56 59 62 65

Q
48.5 51.5 51.5 54 54

R
41 51 54 57 60

Q
65.5 68.5 68.5 71 71

R
42 52 55 58 61

S
53.5 56.5 56.5 59 59

Q
100.5 103.5 103.5 106 106

R
41 51 54 57 60

E S T
69.5 82 72.5 93.5 72.5 100 75 99.5 75 106

40 42.5 58.5 42 46.5 92 42.5 61 83.5 30 52.5 52.5 95 52 33 43 61.5 49.5 95 64 55.5 55.5 101.5 33 55 58.5 58.5 101 58 36 46 98 66.5 64 52 61.5 61 61.5 107.5 36

Note 1) The figures in parentheses are the normally open (N.O.) type dimensions. Note 2) Add 1.5 mm to R and T dimensions for the N.O. spec.

R C

117

Series 56-VVX21/22/23
For Air

Dimensions: Manifold/Base Material: Aluminum


Normally closed (N.C.) : 56-VVX21/56-VVX22/56-VVX23 Normally open (N.O.)

D side

Stations

U side

44

T R Y
72 82 86

F
2-3/8 IN port (Common SUP type) OUT port (Individual SUP type)

H
n-1/8, 1/4 OUT port (Common SUP type) IN port (Individual SUP type)

L2 (N) N K D B (B) C L1 H F K

G1/2 32 25

(mm) Model Dimension 2 86 100 108 126 3 122 136 154 172 4 158 172 200 218 n (Stations) 5 6 7 194 230 266 208 244 280 246 292 338 264 310 356 8 302 316 384 402 9 338 352 430 448 10 374 388 476 494 (mm) Model

VVX21 VVX22 VVX23

L1 L2 L1 L2

A
38 49 49

B
20.5 26.5 26.5

Individual SUP type

(B)

C
10.5 13 13

D
11 13 13

E
25 30 30

F
32 40 40

H
36 46 46

J
12 15 15

K
7 9 9

M
6.5 8.5 8.5

N
Note 1)

VVX21 VVX22 VVX23

17.5 22.5 22.5

57.5 (65.5) 66.5 (74.5) 71.5 (80) (mm) Electrical entry (Built-in full-wave rectifier type) Note 2) Grommet Conduit DIN terminal Conduit terminal

Model

Grommet

Conduit

Electrical entry DIN terminal

Conduit terminal

Q VVX21 VVX22 VVX23


19.5 22.5 25.5

R
48.5 58.5 63

S
40 43 46

T
41 51 55.5

U
46.5 49.5 52

V
58.5 61.5 64

T
40.5 50.5 55

W
61 64 66.5

X
92 95 98

Y
73 83 87.5

Q
30 33 36

R
44.5 54.5 59

S
48.5 51.5 54

T
40 50 54

280

U
53.5 56.5 59

300

V
65.5 68.5 71

T
41 51 55

W
69.5 72.5 75

100.5 103.5 106

Note 1) The figures in parentheses are the normally open (N.O.) type dimensions. Note 2) Add 1.5 mm to R, T and Y dimensions for the N.O. spec.

118

2 x M

Series 56-VVX21/22/23
For Water, Oil, Steam

Dimensions: Manifold/Base Material: Brass, Stainless Steel


Normally closed (N.C.) : 56-VVX21/56-VVX22/56-VVX23 Normally open (N.O.)
D side
Stations 1 2 3 4 5 n

U side

44

T R
(Pitch) L3 L2 L1 2.5 (mm) 9 10 310.5 345 322.5 357 334.5 369 346.5 385 358.5 397 370.5 409 373.5 415 385.5 427 397.5 439 3 stns. x 3 2 stns. x 2 + 3 stns. x 2 (mm)

16

(N) N

2-3/8 IN port

C B

16

G1/2 32 25

n (Stations) 7 8 2 3 4 5 6 L1 69 103.5 138 172.5 207 276 241.5 L2 VVX21 253.5 81 115.5 150 184.5 219 288 L3 265.5 93 127.5 162 196.5 231 300 L1 269.5 77 115.5 154 192.5 231 308 L2 VVX22 281.5 89 127.5 166 204.5 243 320 L3 293.5 139.5 178 216.5 255 332 101 L1 290.5 83 124.5 166 207.5 249 332 L2 VVX23 302.5 95 136.5 178 219.5 261 344 L3 314.5 107 148.5 190 231.5 273 356 Manifold composition 2 stns. x 1 3 stns. x 1 2 stns. x 2 2 stns. + 3 stns. 3 stns. x 2 2 stns. x 2 + 3 stns. 2 stns. + 3 stns. x 2 Model Dimension

Model

A
49 57 57

B
24.5 28.5 28.5

C
20 25.5 25.5

D
28 30 30

E
4.5 5.5 5.5

F
38 42 42

H
17.3 19.3 20.8

J
34.5 38.5 41.5

N
Note 1)

VVX21 VVX22 VVX23

56 (64) 64.5 (72.5) 72.5 (81) (mm) Electrical entry (Built-in full-wave rectifier type) Note 2) Grommet Conduit DIN terminal Conduit terminal

Model

Grommet

Electrical entry Note 2) Conduit DIN terminal

Conduit terminal

Q VVX21 VVX22 VVX23


19.5 22.5 25.5

R
47 56.5 64

S
40 43 46

T
39.5 49 56.5

U
46.5 49.5 52

V
58.5 61.5 64

T
39 48.5 56

W
61 64 66.5

X
92 95 98

Y
71.5 81 88.5

Q
30 33 36

R
43 52.5 60

S
48.5 51.5 54

T
38 47.5 55

280

U
53.5 56.5 59

300

V
65.5 68.5 71

T
39 48.5 56

W
69.5 72.5 75

D F X
100.5 103.5 106

5.5

n-1/4, 1/8 OUT port

21

Y Y
70 80 87
Note 1) The figures in parentheses are the normally open (N.O.) type dimensions. Note 2) Add 1.5 mm to R, T and Y dimensions for the N.O. spec.

119

Decentralised Serial Wiring

Series

56-EX250
How to Order

For more details, other specifications, dimensions, see the specific catalogue.

II 3GD EEx nA II T5 X 5C Ta 45C IP67

Input block SI unit

56 - EX250
ATEX category 3

S PR1
PR1

X42
PROFIBUS-DP

Communication protocol

SI Unit Specifications
Model Applicable PLC/Communication protocol Communication speed Output point Output style Connection load Power supply for block Residual voltage Input point Input style Connection block Power supply for block Current supply for block 56-EX250-SPR1-X42 PROFIBUS-DP (9.6/19.2/45.45/93.75/187.5/500 kbit/sec), (1.5/3/6/12 Mbit/sec) Max. 32 points P-ch MOS-FET open drain type Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surge voltage (made by SMC) 24 VDC + 10%/5% 0.3 VDC or less Max. 32 points TTL 56-EX250-IE2-X43 24 VDC 20% Max. 1 A 0.1A or less (inside o SI unit) IP67 250

Output specifications

Input specifications

Current consumption Protection structure Weight (g)

How to Order
Input block

56 - EX250
Block type
2

IE 2

X43

M12 connector, 4 inputs

ATEX category 3

Input Block Specifications


Model

Applicable sensor Rated voltage Ve Logical ''1'' input voltage VH Logical ''0'' input voltage VL Logical ''1'' input current IH Logical ''0'' input current IL 2 wire type sensor connection Input delay time Sensor supply current Protection structure Weight (g)

56-EX250-IE2-X43 Current source type (PNP output) Current sink type (NPN output) / converted by a switch

24 VDC (Max. 1V of voltage effect against SI unit supply voltage) 16 V to 30 V 0 V to 5 V 5 mA Min. 1.2 mA Max. Possible 3 m sec. Typ. Maximum 30 mA/Sensor IP67 90 g

120

Decentralised Serial Wiring

Series

56-EX500
How to Order

II 3GD EEx nA II T4 X 5C Ta 45C IP65 (Gateway 56-EX500-GPR1A)

For more details, other specifications, dimensions, see the specific catalogue.

II 3GD EEx nA II T5 X 5C Ta 45C IP67 (SI Unit 56-EX500-Q01, 56-EX500-S01) II 3GD EEx nA II T5 X 5C Ta 45C IP65 (Input Unit 56-EX500-IB1, Input Block 56-EX500-IE)

Gateway (GW) Unit

56 - EX500
ATEX category 3

G PR1A
Communication protocol
PR1A PROFIBUS-DP

Input Unit Manifold

Gateway (GW) Unit Specifications


Model Applicable PLC/Communication protocol Communication speed Rated voltage Power supply voltage range Current consumption Inputs/outputs points Input/output branches Branch cable Branch cable length Communication connector Power connector Ambient operating temperature/humidity Protection structure Weight (g) EX500-GPR1A PROFIBUS-DP (EN50170) (9.6/19.2/45.45/93.75/187.5/500 kbit/sec), (1.5/3/6/12 Mbit/sec) 24 VDC Input and control unit power supply: 24 VDC 10% Solenoid valve power supply: 24 VDC + 10%/5% (Warning of voltage drop at approx. 20 V or less) 200 mA or less (single GW unit) Maximum 32 inputs/64 outputs 4 branches (8 inputs/16 outputs per 1 branch) 8 core PVC coated cable 5 m or less (Max. total length: 10 m or less) M12 connector (8 pins, socket) M12 connector (5 pins, plug) +5 to +45C at 35% to 85% RH (without condensation) IP65 470

121

Series 56-EX500
How to Order Input manifold
Example M8 and M12 on a single manifold
Unit side

EEX500
E T M

IB1

E 4

Input unit specification Connector type


M8 connector M12 connector M8 and M12 mixed

Input block 56-EX500-IE1 (2 sets) Input block 56-EX500-IE3 (2 sets)

56

Stations
1 1 station 4 stations

-EX

50

0-I

B1

EEX500-IB1-M4 1 set 56-EX500-IE1 2 sets 56-EX500-IE3 2 sets


End block side

Input block

56 - EX500
Block type
1 2 3 4 5 6

IE 1

When ordering an input block manifold, enter the Input manifold part no. + Input block part no. together. The input block , end block and DIN rail are included in the input manifold. Refer to How to Order below.

ATEX category 3

M8 connector, PNP specification M8 connector, NPN specification M12 connector, PNP specification M12 connector, NPN specification 8-point integrated type, M8 connector, PNP specifications 8-point integrated type, M8 connector, NPN specifications

Input Unit Specifications


Connection block Communication connector Number of connection blocks Block supply voltage Block supply current Current consumption Short circuit protection Enclosure Weight (g)
Note)

Input Block Specifications


Applicable sensor Sensor connector Number of inputs Rated voltage Logical ''1'' input voltage Logical ''0'' input voltage Logical ''1'' input current Logical ''0'' allowable current Input delay Indicator Insulation Sensor supply current
Ambient operating temperature/humidity

Current source type input block (PNP input block) or Current sink type input block (NPN input block) M12 connector (8 pins, plug) Maximum 4 blocks 24 VDC 0.3 A maximum 100 mA or less (at rated voltage) 1A Typ. for each unit (shut off power supply) To restart, remove power to the GW unit once, then reapply it. IP65 100 (Input unit + end block)

Current source type (PNP output)

Current sink type (NPN output)

M8 connector (3 pins) or, M12 connector (4 pins) 2 inputs/8 inputs (M8 only) 24 VDC 15 V to 26.4 V 0 V to 5 V 5 mA Typ. 1.5 mA 0 V to 8 V 19 V to 26.4 V 5 mA Typ. 1.5 mA 1 m sec. or less Green LED Not provided Maximum 30 mA/Sensor
+5 to +45C at 35% to 85% RH (without condensation)

Note) Not including the DIN rail weight.

Enclosure Weight (g)

IP65 [For M8: 20] [For M12: 40] [8 point integrated type, for M8: 55]

122

Series 56-EX500
Dimensions 8 point integrated type Input Block
47 8 31 (Pitch) P=12

21

DIN rail

35

5.5

110 125(Rail mounting pitch:12.5) 135.5

(12.5) 5

44.2

(7.5)

M12 Input Block


47 31 (Pitch) P=20 25 DIN rail

35

5.5

32.2

56-EX500-IB1

39.7
60

L1 L2(Rail mounting pitch:12.5) L3

44.2

Stations

L1 L2 L3

1 2 3 4 82 102 122 142 100 112.5 137.5 162.5 110.5 123 148 173

32.2

56-EX500-IB1

(7.5)

46.9

49

123

Series 56-EX500
Dimensions 8 Input Block
8

47 31

(Pitch) P=12

21

DIN rail

35

5.5

L1 L2(Rail mounting pitch:12.5) L3 5

44.2

(7.5)

56-EX500-IB1

Stations

L1 L2 L3

1 2 3 4 74 86 98 110 87.5 100 112.5 125 98 110.5 123 135.5

M8 and M12 mixed Input Block


47 31 (Pitch) P=12 (Pitch) P=20 25 DIN rail

35

5.5

32.2

39.7

49

60 No. L No. L 0 98 4 148 1 110.5 5 160.5 2 123 6 173 3 135.5 32.2


56-EX500-IB1

Stations

0 1 2 3 4

M8 input block(m) Connector type: For M8 Input 0 1 2 3 4 Block 0 1 2 3 (n=1 to 4) 1 2 3 4 L dimension 2 3 4 4 5 Connector type: For M8 and M12 6
mixed (m+n=2 to 4)

124

M12 Input Block(n)

Connector type: For M12 Input Block (n=1 to 4)

(7.5)

39.7 46.9

44.2

Safety Instructions
The following safety instructions are intended to prevent hazardous situations and/or equipment damage. The instructions indicate the level of potential hazard by labeling "Caution", "Warning", or "Danger". To ensure safety, please observe all safety practices, including ISO 4414 Note 1), JIS B8370 Note 2).

Caution : Operator error could result in injury or equipment damage. Warning : Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possibility of serious injury or loss of life.
Note 1) ISO 4414: Pneumatic fluid power -- Recommendations for the application of equipment to transmission and control systems. Note 2) JIS B 8370: Pneumatic system axion

Warning
1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility with a specific pneumatic system must be based on specifications or post analysis and/or tests to meet a specific requirement.

2.Only trained personnel should operate pneumatically machinery and equipment.


Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators.

3. Do not service machinery/equipment or attempt to remove components until


the safety of the worker is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed after confirming that all safety locked-out control positions are engaged. 2. When equipment is to be removed, confirm that all safety precautions have been followed. Cut the pressure supply for the equipment and exhaust all residual compressed air in the system. 3. Before restarting any machinery/equipment exercise caution to prevent quick extension of a cylinder piston rod, etc. (Bleed air into the system gradually to create back pressure.)

4. Contact SMC if the product will be used in any of the following conditions.
1. Conditions and environments beyond the given specifications or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverage, recreation equipment, emergency stop circuits, press applications or safety equipment. 3. An application which has the possibility of having a negative affect on people, property, or applications with special safety requirements.

125

Common Precautions
Be sure to read before handing. Selection
3. Drain

Warning
1. Confirm specifications.
Products represented in this catalogue are designed for use in compressed air applications only (including vacuum), unless otherwise indicated. Do not use the products outside of their designed parameters. Contact SMC when using the product with fluids other than compressed air (including vacuum).

If condensation in the air filter is not emptied on a regular basis, condensation that flows to the outlet side can cause a malfunction. If it is difficult to check and remove, installation of a filter with an auto-drain function is recommended. Refer to Best Pneumatics for details on compressed air quality. Do not use compressed air which includes chemicals, synthetic oils containing organic solvents, salt, or corrosive gases, etc., as this can cause damage or malfunction.

4. Use clean air

Installation

Environment

Warning
1. Do not install unless the safety instructions have been read and understood.
Keep this catalogue on file for future reference.

Warning
1. Do not use in an environment where the product is directly exposed to corrosive gases, chemicals, sea water, water or steam. 2. In locations which receive direct sunlight, provide a protective cover, etc. 3. Do not operate in locations where vibration or impact occurs. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5. Avoid striking the product with a metallic object. 6. Avoid using this product in a non-explosive environment which can become explosive due to air leakage.

2. Maintenance
When installing the product, allow for maintenance access.

3. Tightening torque

When installing the product, follow the torque specification.

Piping

Caution
1. Before piping
Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. When installing piping or a fitting into a port, make sure that the sealant material does not clog the pressure port. Leave the first 1.5 to 2 thread turns exposed at the end of the pipe/ fitting when using sealant tape.

Maintenance

2. Sealant tape

Warning
1. Maintenance procedures are outlined in the operation manual.
Failure to follow proper procedures can result in product malfunction and or lead to damage to the equipment or machine. If handled improperly, compressed air can be dangerous. Assembly, handling and repair of pneumatic systems should only be performed by qualified personnel. Remove condensation from the filter bowl on a regular basis.

2. Maintenance

Air Supply

Warning
1. Operation fluid
Consult with SMC when using the product in applications which use fluids other than compressed air (including vacuum). Regarding products for general fluids, consult with SMC regarding applicable fluids. Compressed air containing larger mount of drainage can cause malfunction of pneumatic equipment. Please installation of an air dryer and mist separator (Drain Catch) before air filter.

3. Drain

4. Shut down before maintenance

Before attempting any kind of maintenance confirm that the supply pressure is shut off and all residual air pressure is released from the system to be worked on. Apply operating pressure and power to the equipment, then check for proper operation and possible air leaks. If operation is abnormal, verify product set-up parameters.

5. Start-up after maintenance

2. Large amount of drainage.

6. Do not make any modification to the product.

126

SMC product information


Product Hand valve Regulator Manifold regulator Air filter Mist separator Micro mist separator Filter regulator Lubricator Finger valve 3 port residual pressure realase valve Cross interface Speed controller Check valve Shuttle valve Quick exhaust valve Fitting One-touch fittings Series Category

VH200/201/400/401 AR10/20/25/30/40/50/60 ARM2500/3000 AF10/20/30/40/50/60 AFM20/30/40 AFD20/30/40 AW10/20/30/40 AL10/20/30/40/50/60 VHK2/3 VHS20/30/40/50 Y24~54 AS AK,AKH VR12 AQ KQ KA, KAB, KC, KEC, KG, KJ, KM, KP*, KQ*, KR*, KS, KW, KX 1) Out of scope DM*, KDM KF* H, DL, L, LL M, MS KK* T, TS, TU IL100 IL201/211/220 IR1000~3000 IRV1000~3000 IW212~217 CCT ADH4000 AFF2B~AFF75B AM150~850 AMD150~850, AMD800~1000 AME150~850 AMF150~1000 AMG150~850 AMH150~850 AMR3000~6000 AN200-900, AN103
Consult SMC for individual part numbers and details of compliant models.

Others

Multi-connector Insert fittings Self-align fittings Miniature fittings S Couplers Tube Booster relay Lock up valve Precision regulator Vacuum Regulator Filter Regulator Air-hydro Converter Heavy duty Auto Drain Main line Filter Mist Separator Micro mist Separator Super mist Separator Odour Removal Filter Water Separator Micro mist Separator with Prefilter MR unit Silencer

Note 1) An "Out of scope" product is one that can be used without certification in Zone 1, 2 (gas) or Zone 21, 22 (dust).

127

EUROPEAN SUBSIDIARIES:

Austria SMC Pneumatik GmbH (Austria). Girakstrasse 8, A-2100 Korneuburg Phone: +43 2262-62280, Fax: +43 2262-62285 E-mail: office@smc.at http://www.smc.at

France SMC Pneumatique, S.A. 1, Boulevard de Strasbourg, Parc Gustave Eiffel Bussy Saint Georges F-77607 Marne La Vallee Cedex 3 Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010 E-mail: contact@smc-france.fr http://www.smc-france.fr

Netherlands SMC Pneumatics BV De Ruyterkade 120, NL-1011 AB Amsterdam Phone: +31 (0)20-5318888, Fax: +31 (0)20-5318880 E-mail: info@smcpneumatics.nl http://www.smcpneumatics.nl

Spain SMC Espaa, S.A. Zuazobidea 14, 01015 Vitoria Phone: +34 945-184 100, Fax: +34 945-184 124 E-mail: post@smc.smces.es http://www.smces.es

Belgium SMC Pneumatics N.V./S.A. Nijverheidsstraat 20, B-2160 Wommelgem Phone: +32 (0)3-355-1464, Fax: +32 (0)3-355-1466 E-mail: post@smcpneumatics.be http://www.smcpneumatics.be

Germany SMC Pneumatik GmbH Boschring 13-15, D-63329 Egelsbach Phone: +49 (0)6103-4020, Fax: +49 (0)6103-402139 E-mail: info@smc-pneumatik.de http://www.smc-pneumatik.de

Norway SMC Pneumatics Norway A/S Vollsveien 13 C, Granfos Nringspark N-1366 Lysaker Tel: +47 67 12 90 20, Fax: +47 67 12 90 21 E-mail: post@smc-norge.no http://www.smc-norge.no

Sweden SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 71 Huddinge Phone: +46 (0)8-603 12 00, Fax: +46 (0)8-603 12 90 E-mail: post@smcpneumatics.se http://www.smc.nu

Bulgaria SMC Industrial Automation Bulgaria EOOD 16 kliment Ohridski Blvd., fl.13 BG-1756 Sofia Phone:+359 2 9744492, Fax:+359 2 9744519 E-mail: office@smc.bg http://www.smc.bg

Greece S. Parianopoulus S.A. 7, Konstantinoupoleos Street, GR-11855 Athens Phone: +30 (0)1-3426076, Fax: +30 (0)1-3455578 E-mail: parianos@hol.gr http://www.smceu.com

Poland SMC Industrial Automation Polska Sp.z.o.o. ul. Konstruktorska 11A, PL-02-673 Warszawa, Phone: +48 22 548 5085, Fax: +48 22 548 5087 E-mail: office@smc.pl http://www.smc.pl

Switzerland SMC Pneumatik AG Dorfstrasse 7, CH-8484 Weisslingen Phone: +41 (0)52-396-3131, Fax: +41 (0)52-396-3191 E-mail: info@smc.ch http://www.smc.ch

Croatia SMC Industrijska automatika d.o.o. Crnomerec 12, 10000 ZAGREB Phone: +385 1 377 66 74, Fax: +385 1 377 66 74 E-mail: office@smc.hr http://www.smceu.com

Hungary SMC Hungary Ipari Automatizlsi Kft. Budafoki ut 107-113, H-1117 Budapest Phone: +36 1 371 1343, Fax: +36 1 371 1344 E-mail: office@smc-automation.hu http://www.smc-automation.hu

Portugal SMC Sucursal Portugal, S.A. Rua de Eng Ferreira Dias 452, 4100-246 Porto Phone: +351 22-610-89-22, Fax: +351 22-610-89-36 E-mail: postpt@smc.smces.es http://www.smces.es

Turkey Entek Pnmatik San. ve Tic Ltd. Sti. Perpa Tic. Merkezi Kat: 11 No: 1625, TR-80270 Okmeydani Istanbul Phone: +90 (0)212-221-1512, Fax: +90 (0)212-221-1519 E-mail: smc-entek@entek.com.tr http://www.entek.com.tr
DiskArt 1988

Czech Republic SMC Industrial Automation CZ s.r.o. Hudcova 78a, CZ-61200 Brno Phone: +420 5 414 24611, Fax: +420 5 412 18034 E-mail: office@smc.cz http://www.smc.cz

Ireland SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Phone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500 E-mail: sales@smcpneumatics.ie http://www.smcpneumatics.ie

Romania SMC Romania srl Str Frunzei 29, Sector 2, Bucharest Phone: +40 213205111, Fax: +40 213261489 E-mail: smcromania@smcromania.ro http://www.smcromania.ro

UK SMC Pneumatics (UK) Ltd Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN Phone: +44 (0)800 1382930 Fax: +44 (0)1908-555064 E-mail: sales@smcpneumatics.co.uk http://www.smcpneumatics.co.uk
DiskArt

Denmark SMC Pneumatik A/S Knudsminde 4B, DK-8300 Odder Phone: +45 70252900, Fax: +45 70252901 E-mail: smc@smc-pneumatik.dk http://www.smc-pneumatik.com

Italy SMC Italia S.p.A Via Garibaldi 62, I-20061Carugate, (Milano) Phone: +39 (0)2-92711, Fax: +39 (0)2-9271365 E-mail: mailbox@smcitalia.it http://www.smcitalia.it

Russia SMC Pneumatik LLC. Sredny pr. 36/40, St. Petersburg 199004 Phone.:+812 118 5445, Fax:+812 118 5449 E-mail: marketing@smc-pneumatik.ru http://www.smc-pneumatik.ru

Estonia SMC Pneumatics Estonia O Laki 12-101, 106 21 Tallinn Phone: +372 (0)6 593540, Fax: +372 (0)6 593541 E-mail: smc@smcpneumatics.ee http://www.smcpneumatics.ee

Latvia SMC Pneumatics Latvia SIA Smerla 1-705, Riga LV-1006, Latvia Phone: +371 781-77-00, Fax: +371 781-77-01 E-mail: info@smclv.lv http://www.smclv.lv

Slovakia SMC Priemyseln Automatizci, s.r.o. Nmestie Martina Benku 10, SK-81107 Bratislava Phone: +421 2 444 56725, Fax: +421 2 444 56028 E-mail: office@smc.sk http://www.smc.sk

Finland SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02031 ESPOO Phone: +358 207 513513, Fax: +358 207 513595 E-mail: smcfi@smc.fihttp://www.smc.fi

Lithuania SMC Pneumatics Lietuva, UAB Savanoriu pr. 180, LT-01354 Vilnius, Lithuania Phone: +370 5 264 81 26, Fax: +370 5 264 81 26

Slovenia SMC industrijska Avtomatika d.o.o. Grajski trg 15, SLO-8360 Zuzemberk Phone: +386 738 85240 Fax: +386 738 85249 E-mail: office@smc-ind-avtom.si http://www.smc-ind-avtom.si

OTHER SUBSIDIARIES WORLDWIDE: ARGENTINA, AUSTRALIA, BOLIVIA, BRASIL, CANADA, CHILE, CHINA, HONG KONG, INDIA, INDONESIA, MALAYSIA, MEXICO, NEW ZEALAND, PHILIPPINES, SINGAPORE, SOUTH KOREA, TAIWAN, THAILAND, USA, VENEZUELA

http://www.smceu.com http://www.smcworld.com
SMC CORPORATION
1st printing JU printing JU 5 UK Printed in Spain

1-16-4 Shimbashi, Minato-ku, Tokio 105 JAPAN; Phone:03-3502-2740 Fax:03-3508-2480


Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.