Sie sind auf Seite 1von 2

MODEL TLL-5902

International size reference: 1/2AA, ER14252

TECHNICAL DATA
(Typical values @+25 C for batteries stored for one year or less)

Nominal capacity @ 1 mA, to 2V 1.1 Ah Rated voltage 3.6 V Maximum recommended continuous current 50 mA Maximum pulse current capability 100 mA Weight 9.6 g (0.339 oz) Volume 4 cc Operating temperature range -55 C to +85 C Li metal content approx. 0.35 g U.L. Component Recognition, MH 12193
Volts
4.0

DISCHARGE CHARACTERISTICS @ +25C

3.5

3.0

2.5

2.0
220 ~14 mA (0.80 Ah) 470 ~7 mA (0.97 Ah) 3.6 k ~1 mA (1.10 Ah) 40 k 220 k 27 k ~0.125 mA ~40 A ~17 A (1.08 Ah) (1.02 Ah) (0.92 Ah)

1.5

TERMINATIONS & ORDERING NO.


SUFFIX- /S STANDARD 15-5902-21530 15-5902-31530 15-5902-41530 15-5902-36530 15-5902-52530 15-5902-53530 SUFFIX- /T SOLDER TABS SUFFIX- /P AXIAL PINS

1.0 1 10 100 1000 10000 100000 Hours

SUFFIX- /PT2 RADIAL PINS SUFFIX- /TP POLARIZED TABS SUFFIX- /PT POLARIZED TABS

Volts
3.7 3.5 3.3 3.1 2.9 2.7 2.5 -50

VOLTAGE VS. TEMPERATURE


4 A 17 A

Ah
1.2
-30 C

CAPACITY VS. CURRENT

1.0
25 C

0.8
0.8 mA

0.6
2 mA

55 C 72 C

0.4
7 mA 14 mA

0.2 -30 -10 10 30 50 70 90 C 0.01 0.1 1 10

mA

iXtra - Long Term High Performance


Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 1501879 Rev. D 11/08 Page 1 of 2

TLL-5902
CELL FEATURES
3.6 V Primary lithium-thionyl chloride (Li-SOCl2) Fast voltage recovery after long term storage and/or usage High energy density High and stable operating voltage Low self discharge rate Bobbin construction Hermetic glass-to-metal-sealing Non-flammable electrolyte

MAIN APPLICATIONS
Utility meters (elect., water & gas) Automatic meter reading RF systems Sensors & monitoring systems Tracking systems Wireless security systems Automotive electronics Industrial electronics Ultra Low Power (ULP)

Volts
3.5 3.4 3.3 3.2 3.1 3.0 2.9 2.8 2.7 0

VOLTAGE RESPONSE AFTER STORAGE


After 1 year After 2 years After 5 years After 10 years

STORAGE CONDITIONS
Cells should be stored in a clean & dry (less than 30 % RH) area

Pulse applied: 10 mA for 1 sec Storage: RT Background current: None

200

400

600

800

1000

1200 msec

For updated information please visit our website www.tadiranbat.com

Volts
3.5

VOLTAGE RESPONSE
After 1 year After 5 years

Volts
3.5

VOLTAGE RESPONSE
After 4 years

3.4

3.4

After 1 year After 7 years

3.3

After 10 years

3.3

After 2 years

3.2

Pulse applied: 10 mA for 100 msec Temperature: RT Background current: 5 A 0 20 40 60 80 100 120 msec

3.2

Pulse applied: 10 mA for 100 msec Temperature: RT Background current: 10 A 0 20 40 60 80 100 120 msec

3.1

3.1

iXtra - Long Term High Performance


Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 1501879 Rev. D 11/08 Page 2 of 2

Das könnte Ihnen auch gefallen