technical data

Systems
Different adapters

Different adapters

Different adapters

15

Air-Conditioner Connection Adapters


KRP928A2S - Interface adapter for Split inverter ..........................................................................2 DTA102A52 - Interface Adapter for Sky Air Series (New type) ...........................................3 DTA103A51 - Wiring Adapter for Other Air Conditioners......................................................4 DTA104A6162 External Control Adapter for Outdoor Unit.................................................5 DTA109A51 - DIII-NET Adapter .................................................................................................................6 DTA107A55 Central Control Adapter Kit ...........................................................................................7

Adapters for External Controllers


DCS302A52 Unification Adapter for Computerized Control.................................................8 KRP4A515253 Wiring Adapter for Electrical Appendices (2) ...............................................9 KRP2A6162 Wiring Adapter for Electrical Appendices(1) ....................................................10 KRP1B6123 Wiring adapter......................................................................................................................11

15

Systems Control Systems

Different adapters

Air-Conditioner Connection Adapters

The following Air-conditioning Connection Adapters (Interface adapter for Sky Air Series, Wiring Adapter for other air-conditioners, Interface Adapter for Outdoor unit control and Mix matching Adapter for K indoor unit) are the interface adapters which are required to connect the air-conditioners with D-BACS System or DIII-NET (High speed multiple transmission system).

1-1
1-1-1

KRP928A2S - Interface adapter for Split inverter


View

1-1-2

Outline

This interface adapter allows to link all split inverter units to the DIII net (F1/F2). Lower and upper group number are set by means of DIP switches as well as the choice between auto restart and no auto restart after power failure.

1-1-3

System Configuration
Centralised remote control 220~240 V AC VRV outdoor unit KRP982A2S 200~240 V AC

VRV indoor unit

Room air conditioner

15
1

Systems Control Systems

Different adapters

1
1-2
1-2-1

Air-Conditioner Connection Adapters


DTA102A52 - Interface Adapter for Sky Air Series (New type)
Outline / Features

This is an interface adapter required for all Sky Air for F type to the subsequent models to connect to the central control equipment (Centralised remote control, Unified ON/OFF controller and Schedule timer), and by combining with the central control equipment, you can set the control mode, such as unified ON/OFF control, timer operation, rejection/acceptance by remote controller operation and etc., and also display the operating status.

1-2-2

Applied Model

All the series of Sky Air from F type to the subsequent models and Packaged Air Conditioner FDYB. But, Interface adapter for Sky Air series (old type) is used for Sky Air series C(D) type.

1-2-3

System Configuration
Centralised remote control 220~240V AC VRV outdoor unit DTA102A52 VRV indoor unit Sky Air indoor unit

1-2-4

Description of Functions

A. Control functions By using this adapter, you can control or monitor the following function from the central control equipment. Description of functions 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. ON/OFF operation Operation/malfunction monitoring Cool/heat changeover Temperature setting Control mode setting for remote controller Test operation Malfunction code display and reset Group control Room temperature monitoring Forced thermostat OFF Filter sign display and reset Air flow direction and air flow rate setting Various monitoring function Turns indoor unit ON or OFF. Monitors operation or error status Temperature setting is possible within the temperature setting range of Sky Air (20~35C for cooling and 15~30C for heating). Restricts remote controller operation for ON/OFF control, cool/heat changeover and temperature setting. (Last command priority/Remote Control Rejection and etc.) Operates the indoor units by Forced thermostat ON. Controls up to 16 indoor units simultaneously. Monitors room temperature if connected to the Parallel interface or the Data station. If the central controller is equipped with the forced thermostat OFF function, it switches the Sky Air to FAN operation. Possible to change the setting by the individual setting mode of the centralised remote control. (Note 1) Thermostat status, Compressor operation status, Indoor fan operation status, Auxiliary electric heater operation status. (Note 2)

NOTES

1 2

The central control equipment should be installed in the system This is possible only when connected to the Data station and monitored by central monitoring panel

B. Not controllable functions This adapter is not corresponding to the following functions. Description of functions Set-back the setting temperature by 2C. (thermostat OFF operation) Lowering the operating noise by reducing the capacity Controls the power consumption by reducing the capacity

1. Energy saving command 2. Low operating noise command 3. Demand control

15
1

Systems Control Systems

Different adapters

1
1-3
1-3-1

Air-Conditioner Connection Adapters


DTA103A51 - Wiring Adapter for Other Air Conditioners
Outline / Features

This is a interface adapter required for other equipment, such as room air-conditioner and other air-conditioner or equipment to connect to the central control equipment (Centralised remote control, Unified ON/OFF controller and Schedule timer), and by combining with the central control equipment, you can set the control mode, such as unified ON/OFF control, timer operation, remote controller rejection/acceptance and etc., and also display the operating status. Especially, this adapter is designed with wide usage to be able to connect the air-conditioner of other manufacturer.

1-3-2

Applied Model
Remark

1 2 3

Applied model Room air-conditioner Other equipment, such as fan etc. Air-conditioner of other manufacturer

NOTE

The adapter should be installed in the electrical box (local supply), which be installed outside of the indoor unit.

1-3-3

System Configuration
Centralised remote control 220~240 V AC VRV outdoor unit DTA103A51 200~240 V AC

VRV indoor unit

Room air conditioner

1-3-4

Specifications
Specifications 220~240V10% (50Hz), 220VAC10% (60Hz) Max. 2.4W -10 ~ + 50 C 95% RH or less 1,060g Outside of the unit (with box)

Rated voltage Power consumption Operating temperature Humidity Weight Approx. Installation method

NOTE

The electric box (local supply) for the adapter is required for the installation, which should be installed outside of the indoor unit. Size: 230 (W) 230 (D) 60 (H)

1-3-5

Specifications of contacts
Output signal Non-voltage constant normally open contact and instantaneous normally open contact (500ms pulse duration) can be changeover by the switch. Contact rating AC voltage 100~240V ; current 1mA~2A DC voltage 5~24V ; current 1mA~3A

Input signal Normal operation signal and error input signal (Normally open contact) Use a contact for micro-current (Max. 12VDC, 1mA) Voltage and non-voltage can be changeover by switch. In case of voltage: Power supply specifications : DC12~24V, 10mA

1-3-6

Description of Functions

Control functions

15
1

By using this adapter, the following control and monitoring can be carried out from central controllers. 1. Start/Stop operation Outputs a non-voltage contact signal to start or stop other air-conditioner, etc. 2. Operation monitor, error monitor Receives a contact signal and monitors operation and error status. Enables you to select whether voltage/non-voltage and whether start/stop error is detected.

Systems Control Systems

Different adapters

1
1-4
1-4-1

Air-Conditioner Connection Adapters


DTA104A6162 External Control Adapter for Outdoor Unit
Outline / Features

By installing this adapter in the indoor unit of VRV series or BS unit connected to DIII-NET (or outdoor unit in case of VRV plus series or VRV inverter K series), it enables you to have individual/simultaneous cool/heat changeover of several outdoor units connected, demand control and low noise control.

NOTE

Demand control and low noise control is possible only for VRV plus series and VRV inverter K series.

1-4-2

Applied Model

The type of adapter differs depending on the model of indoor unit. Applied adapter DTA104A61 DTA104A62

FXCQ FXKQ FXSQ FXBQ FXMQ FXAQ FXLQ FXNQ FXFQ FXHQ

The adapter can also be installed in the outdoor unit of VRV PLUS series and VRV inverter K series.

1-4-3

System Configuration
Outdoor unit (Up to 10 outdoor units can be controlled individually.) DTA104A6162

VRV series indoor unit

1-4-4

Description of Functions

1. Control functions By using an external control adapter for outdoor units, it enables the following controls. However, these functions are of adapter itself and the type of adapter differs depending on the model of indoor unit and BS unit to be installed. 1 2 3 Unified changeover of Cool/Heat mode To change the cool/heat mode of several outdoor units by one remote controller To changes the cool/heat mode of outdoor units by cool/heat centralised remote control or cool/heat remote controller. Demand control When short circuit between (1) and (C) : Approx. 70% When short circuit between (2) and (C) : Approx. 40% When short circuit between adapter terminals (3) and (C) : Forced fan operation (The percentage indicates the ratio of power consumption.) Low noise control

By controlling the capacity of outdoor unit, it reduces the operating noise by 2~3dB. 2. Instruction for installation For VRV plus series and VRV inverter K series, it is possible to switch cool/heat simultaneously only by remote controller for indoor unit or cool/ heat centralised remote control This adapter enables to have demand control and low noise control only for VRV plus series and VRV inverter K series.

15
1

Systems Control Systems

Different adapters

1
1-5
1-5-1

Air-Conditioner Connection Adapters


DTA109A51 - DIII-NET Adapter
Outline / Features

This adapter is intended for increasing the number of indoor units under control. The scalable device helps extend from the existing 128 indoor units up to 1,024 indoor units (in 64 groups under a central controller).

1-5-2

Applied Model

All VRV series models (after Type K)

1-5-3

System Configuration
Outdoor Unit (up to 10 units under control) DTA109A51 Centralised Remote Control

...

Adapter connectable for up to 8 units

Indoor units (up to 128 units under control)

15
1

Systems Control Systems

Different adapters

1
1-6
1-6-1

Air-Conditioner Connection Adapters


DTA107A55 Central Control Adapter Kit
Outline / Features

The DTA107A55 enables packaged units UAT(Y) to be connected to the central control equipment of the VRV system. Functions available include operation setting and monitoring, temperature setting, group control, schedule timer, filter cleaning sign and error alarm.

1-6-2

Applied Model

UAT06 - 21KA and UATY06 21K.

1-6-3

System Configuration

VRV indoor unit Unified on/off control (DCS301B61) Centralised remote control (DCS302B61) Interface adapter for sky air series (DTA102A52) Sky air indoor unit

Schedule timer (DST301B61) Thermistor (Suction air) This adapter is needed for each packaged unit (UAT(Y))

Central control adapter kit (DTA107A55)

Relay circuit

UAT (Y)

15
1

Systems Control Systems

Different adapters

Adapters for External Controllers

The following adapters are interface adapters required for the connection of the central control equipment (Centralised remote control, Unified ON/ OFF controller and Schedule timer) or other external control equipment, such as the central monitoring panel, and enables you to operate ON/OFF or monitor the operating status, malfunction etc. from the central monitoring panel.

2-1
2-1-1

DCS302A52 Unification Adapter for Computerized Control


Outline / Features

This adapter is an interface adapter required to connect the central control equipment (Centralised remote control, Unified ON/OFF controller and Schedule timer) or other external control equipment, such as the central monitoring panel, and enables you to have a unified display (operation/error display) or a unified operation (start/stop command) from the central monitoring panel.

2-1-2

Applied Model

Centralised remote control DCS302B61

2-1-3

System Configuration

1. Unified display Output for display (Monitor output of indoor unit 1-00~4-15) Unification adapter for computerized control DCS302A52 Output for display (Monitor output of indoor unit 5-00~8-15) Unification adapter for computerized control DCS302A52 Centralised remote control No. 1 DCS302B61 (Control of indoor unit 1-00~4-15)

Central monitoring panel

1-00

1-01

8-15

Max. 128 group (Up to 128 units)

Centralised remote (Control of control indoor unit No. 1 5-00~8-15) DCS302B61

Operation and error of all the indoor units controlled by the centralised remote control are output and displayed on the central monitoring panel. 2. Unified control Input for control Output for display (Monitor output Unification adapter for computerized of indoor unit control 1-00~4-15) DCS302A52 Centralised remote control No. 1 DCS302B61 (Control of indoor unit 1-00~4-15)

Central monitoring panel

1-00

1-01

8-15

Max. 128 group (Up to 128 units)

Input for control Output for display Unification adapter Centralised remote (Control of (Monitor output of for computerized control indoor unit indoor unit 5-00~8-15) control No. 1 5-00~8-15) DCS302A52 DCS302B61 Unified display and unified start/stop operation of all the indoor units controlled by the centralised remote control are operative from the central monitoring panel.

15
2

Systems Control Systems

Different adapters

2
2-2
2-2-1

Adapters for External Controllers


KRP4A515253 Wiring Adapter for Electrical Appendices (2)
Outline / Features

This adapter is an interface required to connect the indoor unit with the central monitoring panel. And by installing this adapter in the indoor unit, it enables you to have various remote controls (ON/OFF, temperature setting, operation status display and malfunction display). One adapter can control simultaneously the group of units (Max. 16 units) connected to the remote control wiring line(P1, P2).

NOTES

1 2

This adapter cannot be used together with central control equipment and data station. The model of adapter differs according to the type of indoor unit to be installed. Applied Model
Remark Applied Model Room Air-Conditioner Other Air-Conditioner HRV Unit Remark BRC1B61, 62 etc. are required. DTA10755 is required. Note

2-2-2
Applied Model

VRV Plus Series VRV Inverter K(A) Series VRV Heat Recovery Series Sky Air Series FD and UAT(Y)

2-2-3

VRV Systems

System Configuration
Outdoor unit

To outdoor unit Indoor unit

Wiring adapter for electrical appendices (2) Central monitoring panel On/off by each remote control

NOTES

1 2 3

Marked shows wiring adapter for electrical appendices. Marked indicates the same control range. The wiring adapter for electrical appendices (2) can control simultaneously the group of the units (Max. 16 units) connected to the remote control wiring line (P1, P2). In other words, all the units connected between P1 and P2 terminal have the same control. Point of wiring Wiring adapter for electrical appendices

Indoor unit PC board

Connect with P1-P2 of indoor unit 's terminal Remote control

15
2

Systems Control Systems

Different adapters

2
2-3
2-3-1

Adapters for External Controllers


KRP2A6162 Wiring Adapter for Electrical Appendices(1)
Outline / Features

This is an interface adapter required if the indoor is connected to the central monitor panel. By installing this adapter in the indoor unit, it enables you have various kind of remote control (ON/OFF control, temperature setting, display of operation/malfunction). However, since this adapter is connected to the central control line, all the indoor units connected to the central control line (F1, F2) have to be controlled simultaneously.

NOTES

1 2 3

This adapter cannot be used in conjunction with the central control equipment or the data station. The model of adapter differs depending on the model of indoor unit. Up to 64 indoor units can be controlled. Applied Model
Applied model VRV plus series Remark Applied model Room air-conditioner Other air-conditioner HRV unit Interface adapter for Sky Air series is required for each indoor unit. ! Remark Wiring adapter for other air-conditioning is required for each indoor unit.

2-3-2

VRV systems

VRV inverter K series VRV Heat recovery series Sky Air series

2-3-3

System Configuration
Outdoor unit

To outdoor unit Indoor unit

Wiring adapter for electrical appendices (1)

Central monitoring panel

NOTES

1 2

15
2

Marked with shows the wiring adapter for electrical appendices (1). This adapter controls collectively all the indoor unit connected to the central control line (F1, F2). In other words, all the indoor unit has the same operation control through this adapter from the central monitoring panel. If you want to have a group control the above indoor units, remove the wiring between the outdoor units and install the wiring adapter for electrical appendices for each group.

Point of wiring Wiring adapter for electrical appendices

Indoor unit PC board

Connect with F1-F2 of indoor unit's terminal Remote control

10

Systems Control Systems

Different adapters

2
2-4
2-4-1

Adapters for External Controllers


KRP1B6123 Wiring adapter
Outline/Features

This adapter is required one for each indoor unit when you install the auxiliary electric heater, the humidifier and the fresh-air intake kit. This adapter also can output the signal of the compressor operation/fan operation.

2-4-2

Applied Model

All the indoor unit of VRV system and Sky Air series. (The type of adapter differs depending on the model of indoor unit. For details, refer to the last item of this section.)

2-4-3

System Configuration
Humidifier Wiring adapter Installed in the indoor unit Auxiliary electric heater

Fan operation signal

Compressor operation signal

2-4-4

Description of Functions

1. Compressor operation signal Outputs the compressor operation/stop signal by detecting the thermostat ON/OFF signal from each indoor unit. (No voltage normally open contact, ON when thermostat is ON.) 2. Fan operation signal Outputs the fan operation/stop signal from each indoor unit. (No voltage normally open contact, ON when fan operates.) 3. Attachment of auxiliary heater and humidifier Requires one adapter for each indoor unit when these options are to be installed.

2-4-5

Operation display signal


Contact to output compressor operation signal. Example H.M.: Hour meter (local supply) Contact to output fan operation signal Example RL: Operation lamp (local supply)

15
2

Systems Control Systems

11

Different adapters

15
2

12

Systems Control Systems

2
Systems
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. VRV products are not within the scope of the Eurovent certification programme.