All rights reserved. Printed in the United States of America. The information contained in this document is the exclusive property of ERDAS, Inc. This work is protected under United States copyright law and other international copyright treaties and conventions. No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage or retrieval system, except as expressly permitted in writing by ERDAS, Inc. All requests should be sent to the attention of: Manager, Technical Documentation ERDAS, Inc. 5051 Peachtree Corners Circle Suite 100 Norcross, GA 30092-2500 USA. The information contained in this document is subject to change without notice. Government Reserved Rights. MrSID technology incorporated in the Software was developed in part through a project at the Los Alamos National Laboratory, funded by the U.S. Government, managed under contract by the University of California (University), and is under exclusive commercial license to LizardTech, Inc. It is used under license from LizardTech. MrSID is protected by U.S. Patent No. 5,710,835. Foreign patents pending. The U.S. Government and the University have reserved rights in MrSID technology, including without limitation: (a) The U.S. Government has a nonexclusive, nontransferable, irrevocable, paid-up license to practice or have practiced throughout the world, for or on behalf of the United States, inventions covered by U.S. Patent No. 5,710,835 and has other rights under 35 U.S.C. 200-212 and applicable implementing regulations; (b) If LizardTech's rights in the MrSID Technology terminate during the term of this Agreement, you may continue to use the Software. Any provisions of this license which could reasonably be deemed to do so would then protect the University and/or the U.S. Government; and (c) The University has no obligation to furnish any know-how, technical assistance, or technical data to users of MrSID software and makes no warranty or representation as to the validity of U.S. Patent 5,710,835 nor that the MrSID Software will not infringe any patent or other proprietary right. For further information about these provisions, contact LizardTech, 1008 Western Ave., Suite 200, Seattle, WA 98104. ERDAS, ERDAS IMAGINE, Stereo Analyst, IMAGINE Essentials, IMAGINE Advantage, IMAGINE, Professional, IMAGINE VirtualGIS, Mapcomposer, Viewfinder, and Imagizer are registered trademarks of ERDAS, Inc. Other companies and products mentioned herein are trademarks or registered trademarks of their respective owners.

Preface
This document provides important information about ERDAS ER Mapper 2011. High-level requirements (software and hardware) for installation. Summary of new features and improvements. Facts to know, workarounds, helpful hints, and last-minute information we could not include in the documentation.

For more information regarding ERDAS products, visit our web site at http://www.erdas.com.

Preface Preface

1 1

System Requirements
Computer/Processor
32-bit: Intel Pentium 4 or 100% compatible, 2.4 GHz minimum 64-bit: Intel 64 (EM64T), AMD 64, or 100% compatible, 2.4 GHz minimum Dual-core, quad-core, or higher strongly recommended 2 GB minimum, more strongly recommended 700 MB for installing all software 530 MB for installing all example data Customer data disk space requirements depend upon specific project requirements1 Windows Vista x32 SP2 or higher, Business, Enterprise & Ultimate Windows XP Professional x322 and x64 SP3 or higher Windows 7 x32 and x64 Business & Ultimate3 Windows Vista x64 SP2 or higher, Business, Enterprise & Ultimate Windows Server 2008 x32 and x64 SP2 or higher Adobe Acrobat Reader 7 or higher Internet Explorer 6 and higher with JavaScript enabled, or Firefox 2 and higher with JavaScript enabled Java Runtime 1.6.0.6 will be installed with ERDAS ER Mapper 2010 Microsoft DirectX 9c or higher Display resolution of 1024 X 768 X 32 minimum, higher recommended The latest graphics card drivers recommended

Memory (RAM) Disk Space

Operating Systems

Software

Graphics Displays

System Requirements

Peripherals

DVD Drive required for software installation One Microsoft Windows compatible mouse (scroll wheel recommended) Microsoft Windows supported hardcopy devices4 Software security requires one of the following: Ethernet card with TCP/IP configured, or One USB port for hardware key, or One standard (DB25) parallel port for hardware key

1. Typically, disk I/O is the slow point in geospatial data processing. Fast hard disks can help productivity. SCSI hard disks are typically faster than SATA and IDE drives. Solid state disk drives have quick access time, but sustained rates are slower than traditional spindle hard disks. Disk arrays can improve performance, but certain RAID configurations can slow performance. 2. Microsoft Windows XP x32 has limited large output file sizes. The maximum file size depends upon system configuration and rarely exceeds 70GB. All other supported OS versions do not experience this limitation. 3. Support for Microsoft Windows 7 was developed and tested using Microsoft Windows 7 release candidates and Windows 7 RTM. 4. HP-RTL drivers are recommended. If printing from a Windows x64 operating system the print server will require 64bit print drivers.

These requirements are subject to change. Please visit our web site at http://www.erdas.com for the latest specifications.
12/8/10

System Requirements

Customer Resolutions
ERDAS ER Mapper
Batch
Fixed the Magnetics function in the Mineral Exploration Wizard. [EMP-5722] "Edit or Create ERS Files in Batch" wizard can now create .ers file for any raster directly-readable by ER Mapper. [EMP-5819] Fixed handling of GDA94/L2SAUST and GDA94/L2_PLSA projections. [EMP-5807] Fixed setting of target compression ratio in Rotate or Resample images in Batch Wizard. [EMP-5806] Fixed reading coordinate system of ASTER L1B HDF data. [EMP5812] Fixed saving of algorithms with vector layers. [EMP-5773] Geocoding Wizard now works with vectors as a base image. [EMP5754] Fixed handling of Lat/Long coordinate systems in the Geocoding Wizard. [EMP-5780] Fixed handling of State Plane NAD83 FIPS zone 5005, Alaska Zone 5 projection. [EMP-5801] ERM Pro gridding on 64bit OS has been fixed. [EMP-5759] Fixed binary BIP and binary BIL import. [EMP-5738] Fixed Surfer 6 GS Binary grid import. [EMP-5752] Fixed Oasis Montaj Binary Grid import crashing. This also fixed many other importer crashes in ER Mapper. [EMP-5772] ER Mapper can now save directly to IMAGINE IMG format. [EMP5635] ER Mapper can now write directly to IMAGINE IMG file format. [EMP-5702] Fixed ER Mapper hanging when opening images with GaussKruger/Hartebeesthoek25 coordinate systems. [EMP-5711] Improved reading of Thematic IMG data. [EMP-5737] Improved roaming of algorithms with vector overlays. [EMP-5746] Fixed the ability to edit ERV files in certain coordinate systems. [EMP-5757]

BMG/GDT Database Compression Dataset Header Editor Exports Geocoding

Gridding Imports

Miscellaneous

Customer Resolutions

Fixed handling of data with lost .aux files. [EMP-5774] ECW report now shows the compression ratio. [EMP-5781] Fixed artifacts in displaying some ECW images. [EMP-5786] ER Mapper will not read .EWW files. [EMP-5810] Customers can now choose to display cell size in either decimal degrees or degrees-minutes-seconds. [EMP-5724] Fixed ER Mapper hanging when roaming over vector data. [EMP5755]

Preferences Zoom

Customer Resolutions

Known Issues
ERDAS ER Mapper
Algorithms
Transform tool may report wrong data range for losslesscompressed JP2 files. However, the data remains identical. [EMP5763] It needs example data to work [EMP-5776] TIFF map object may not display correctly. A work-around is to create an ALG that displays the TIF, and then use an ALGORITHM map composition object instead of IMAGE map object. [EMP-5461] "Batch to ECW" wizard may create incorrect file names for some spatial resolutions. i.e. Compressing test.TIF will produce a test.TIF.ecw instead of test.ecw. [EMP-5433] "Edit or Create ERS Files In Batch" wizard's "Restore" function will not work on .ERS files with a non-EPSG projection. Users have to back up and restore the .AUX files manually. [EMP-5679] "Edit ERS Files in Batch" wizard always assumes that TFW file units are meters and will convert from meters to feet for non-meter projections. [EMP-5700] ER Mapper does not currently support RPC map models for NITF data type. [EMP-5615] Compression Wizard does not suport HSI Algorithms. A workaround is to save the ALG to a VDS and then use the VDS as input for the compression process. [EMP-5356] Using the "current window" in compression input will compress the whole window, including any visible space outside of the actual imagery. Use "Adjust Windows Aspect on Load or Zoom" preference or adjust the window extents to match the image exactly to make sure no extra data is compressed. [EMP-5430] 64-bit ECW Compressor in ER Mapper 7.2.2 may get stuck on launch. The workaround is to use the command line compressor instead. [EMP-5688] Compressing or saving color-draped algorithms to a dataset can produce erroneous results. [EMP-5760] Compressing JP2 mosaics to JP2 may fail. [EMP-5789] Saving a subset from the Image Window to TIFF may result in cell size being off, resulting in a shift by a fraction of a pixel. Users are advised to subset into ERS instead. [EMP-5332]

Annotation

Batch

BMG/GDT Database Compression

Exports

Known Issues

Export to EPS does not support algorithms with dynamic links. Use "print to hardcopy" instead. [EMP-5346] Command line exporters will only export a multi-layer .ERS to a 3layer image. The workaround is to create an algorithm with each band in its own surface. [EMP-5368] Importing multi-part line shapefiles is not supported. [EMP-5659] In order to read NAD27(CGQ77) / UTM projections, customers must place their pcgq77-98.gsb into the etc directory. [EMP-5377] The "Geocoding Type" will be reset if it is selected before an input image is specified. [EMP-5678] All raster formats can be used as input for the Gridding Wizard, but not all raster files can be successfully processed. [EMP-5458] Gridding Wizard may fail to read the input data from a UNC path. The workaround is to map a network drive first. [EMP-5653] Gridding Wizard may not work correctly with input images that have a non-EPSG projection. Use data that has an EPSG-compliant projection and use "Find EPSG" to set the correct EPSG code when setting the coordinate system in the Gridding Wizard. [EMP-5830] Importing EROS NLAPS in ER Mapper produces an incorrect result. Use IMAGINE instead. [EMP-5391] Import image files in batch does not currently support IMAGINE IMG format. Use "Import Raster Translated" instead. [EMP-5460] Saving as GeoTIFF may not persist the projection correctly. If such cases occur, ER Mapper will georeference the output as WGS84 Geodetic. [EMP-5532] Batch import in HDF Wizard does not support Level-3 MODIS "Surface Reflectance 8-Day L3 Global 500m" data. The workaround is to use IMAGINE's batch importing capabilities instead. [EMP-5547] ER Mapper Vector layers, as well as any vector import operations only support EPSG projections. [EMP-5712] ER Mapper Professional 7.2 is not officially supported on Windows Vista; however, most of the functions should work normally on Windows Vista Enterprise with User Access Control turned off. [EMP-5331] Instructions to enable dynamic compilation with Visual C++ 2005 Express Edition 1. Download and Install Visual C++ 2005 Express Edition from here: http://www.microsoft.com/express/2005/download/default.aspx

Geocoding

Gridding

Imports

Installation

Miscellaneous

Known Issues

2. Download and Install Windows Platform SDK from here: http://go.microsoft.com/?linkid=7653972 3. Copy C:\Program Files\Microsoft Platform SDK for Windows Server 2003 R2\Lib\Uuid.lib to C:\Program Files\Microsoft Visual Studio 8\VC\lib. (Alternatively, you can obtain the Uuid.lib file from a previous Platform SDK installation). [EMP-5313] Tabular Dataset Wizard fails to display the .tbl files, the workaround is to manually add them as Dynamic Links using the Algorithm Editor tool. [EMP-5463] Cell Values Profile tool may report incorrect values for the upper edge of images. [EMP-5467] Creating FFTs for very large datasets may cause ER Mapper to crash. This issue affects wizards that rely on FFT as well, such as the Desktop Minerals Wizard. [EMP-5495] When compressing images in NITF 2.1 format to ECW using ERDAS ER Mapper, ER Mapper may not correctly read the projection of the NITF data. In this case, use ERDAS IMAGINE to compress the NITF files into ECW. [EMP-5528] Projection/Cellsize Wizard does not work for ERS files with nonEPSG projections. Use the ERS Header Editor instead. [EMP5745] Scattergrams are always printed with a black background. [EMP5454] When printing to a .BMP file, the output will be placed into the TEMP directory. [EMP-5669] When using ERMapper with data registered to EPSG code 2955, you will need to obtain the file que27-98.gsb. This file should be placed in the folder $IMAGINE_HOME/etc for use with ERDAS ERMapper 2010. [EMP-5438] For .ers files with no DATUM field, ER Mapper will show a random EPSG code for image's projection. This case only applies to corrupt ERS files. [EMP-5557] "Edit ERS Files in Batch" wizard cannot set projections without EPSG code. [EMP-5695] Zooming in, zooming out, and roaming while holding the middle mouse button may rarely cause ER Mapper to freeze. [EMP-5269] Saving as .ers may produce files with "metre" as units. This may cause problems with some versions of ArgGIS. The workaround is to edit the ERS file in a text editor and change the unit name to "meters". [EMP-5515]

Printing

Reprojection-on-the-fly

Roaming Save As

Known Issues

Saving datasets with State Plane coordinate systems may occasionally output a different projection into the TIFF. The resulting projection will be equivalent to the input State Plane projection, but will not be identified as such. [EMP-5645] ER Mapper may fail to save large datasets to NITF. [EMP-5657] Save As NITF may fail on very large input data. [EMP-5690] Histogram calculation in the Transform tool cannot be performed if an algorithm contains layers with "Sunshade" turned on. The workaround is to temporarily turn off the "Sunshade", let the Transform tool calculate the histogram, then re-enable "Sunshade". [EMP-5587] BIL/HDR datasets are misregistered by half a pixel. [EMP-5448] If customers previously mosaiced IMG data with ER Mapper, they may notice that if the images had black edges, they are no longer transparent in ER Mapper 2010. To correct this behavior, customers must set the NODATA values in the input IMG files. [EMP-5560]

Transforms

Translator related

Known Issues

10

Das könnte Ihnen auch gefallen