Contoh alat pemadam api Fire Extinguishers Dry Chemical Powder The dry chemical powder fire extinguisher

is one of the most versatile fire extinguishers available. This extinguisher is effective on Class A (Carbonaceous material such as paper), Class B (Flammable liquids) & Class C (Flammable gas) fires. Therefore, dry powder is the ideal extinguishant where there is dangerous mixed fire risks. Only fire involving carbon disulphite and flammable metals such as magnesium and sodium should be avoided. Dry chemical powder is a non conductor of electricity and is not dangerous to human beings or animals and it is a free flowing powder with a composition based on ammonium phosphate and sulphate with special additives to improve fluidity and storage.

Dry Chemical Powder Cylinder Data Propellant Code No. Capacity, kg Working pressure, Bar (Psi) Test pressure, Bar (Psi) Discharge time, sec. Overall height, mm Cylinder diameter, mm Overall weight, kg Body material Design Paint finish Carton box size, mm Type of extinguishant Type of fire Stored pressured Type (Nitrogen) FEX132-MS-010-BL FEX132-MS-020-BL FEX132-MS-045-BL FEX132-MS-060-BL 1.0 2.0 4.5 6.0 12 (174) 14 (203) 25 (362.5) 7-14 8-16 12-22 14-24 340.0 390.0 475.0 84.5 109.5 157.0 1.9 3.3 7.8 9.3 Cold Roll Steel Manufactured and approved to MS 1179, 1990, (BS 5423) Blue 110x125x345 130x165x415 185x205x490 ABC Powder (Ammonium Phosphate) A, B, C, E

Foam And Water Foam Fire Extinguisher is suitable for Class A & B fire. It smothers the flame, depriving the fire of oxygen. Water Fire Extinguisher cools the fire by removing the heat needed to sustain burning and prevents glowing embers from re-igniting. It is suitable for Class A fire.

Foam and Water Fire Extinguisher Cylinder Data Type Code No. Capacity, (litre) Propellant Working pressure, Bar (Psi) Test pressure, Bar (Psi) Discharge time, sec. Overall Height, mm Cylinder diameter, mm Full weight (kg) Cartridge size Carton size, mm Design Body material Paint finish Type of extinguishant Class of fire Fire rating Temperature range Foam Fire Extinguisher Pressure Cartridge FEX138-MS-090-PC FEX088-MS-090-PC 9.0 Nitrogen 14 (203) 25 (363) 40 635 181 13.1 205x205x650 BS 5423 Cold Roll Steel Pale Cream AFFF Foam A, B 13A, 55B +1 to 60C 40 635 181 13.5 75 gm 9.0 CO2 14 (203) Water Fire Extinguisher Pressure Cartridge FEX137-MS-090FEX078-MS-090RD RD 9.0 9.0 Nitrogen CO2 14 (203) 14 (203) 25 (363) 65 65 635 635 181 181 13.1 13.5 55 gm 205x205x650 BS 5423 Cold Roll Steel Red Water A 13A +1 to 60C

Carbon Dioxide Carbon dioxide (CO2) is effective on Class B (flammable liquid) and Class C (gas) fires. It is electrically non conductive and does not deposit residue therefore safe for fighting fires in electrical equipment. SRI CO2 fire extinguisher is available in three types of cylinder material: Carbon Steel, Aluminium Alloy and Chromium Molybdenum.

Carbon dioxide (CO2) Cylinder Data Material Code No. Capacity, kg (lb) Working pressure, Bar Overall height, mm Overall diameter, mm Cylinder Test pressure, Bar Discharge time, Sec Full weight, kg Paint finish Test Rating Temperature range Discharge range Carton box size, mm Operating head Type of extinguishant Class of fire Material Code No. Capacity, kg Overall height, mm Overall diameter, mm Full weight, kg FEX139-CS-012-BK 1.25 (2.75) 410 115 7-10 6.1 13B 175x180x510 Carbon Steel FEX139-CS-022-BK FEX139-CS-045-BK 2.2 (5.00) 4.5 (10.00) 60.0 610 610 115 153 250 10-12 12-14 9.8 17 Black 21B 34B -20 to 60C 3 meter 180x195x665 230x230x715 Brass Carbon Dioxide B, C FEX139-CS-070-BK 7.0 (15.00) 850 153 16-20 22 55B 200x225x925

Aluminium Alloy FEX139-LA-020-RD FEX139-LA-050-RD 2.0 560 111 5.5 5.0 700 152 12.5

Chromium Molybdenum FEX139-CM-022FEX139-CM-045BK BK 2.2 4.5 640 700 105 138 8.5 14.0