Sie sind auf Seite 1von 7

VERTICAL

MOTORS

Operating Characteristics - Vertical HOLLOSHAFT Motors


High Thrust - P Base, Three Phase, Weather Protected Type (WPI), Standard Efficient

CONVERSION
CENTER

RPM

% EFFICIENCY

% POWER FACTOR

FULL LOAD

LOCKED

PULLOUT

TORQUE @

(STARTING)

BREAKDOWN

NEMA
CODE

1/2
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

LOCKED
STARTING

FULL LOAD
SPEED

7.5

1200

1175

86.5

87

85.4

78.9

72.3

60.6

10.3

57.7

33.5

188

263

10

1200

1175

87.5

88.7

87.7

80.8

75.2

64.4

13.2

73.1

44.8

188

256

1800

1770

89.5

91.1

90.2

83.9

79.2

69.6

18.7

114

44.5

210

270

1200

1175

88.5

90.2

89.8

81.8

77.5

68.1

19.4

99.9

67

169

234

3600

3540

88.5

89.8

89.1

88.6

87

81.5

23.9

150.4

29.7

169

246

1800

1768

89.5

91.5

91.3

85.6

83

75.8

24.3

135

59.5

194

244

1200

1170

88.5

90.6

90.7

84.1

81.6

74.8

25.2

126

89.6

161

218

3600

3535

89.5

91.1

90.7

87.8

87.3

83.3

29.8

180

37.2

154

225

1800

1765

88.5

90.7

90.6

83.1

79.2

69.8

32

177

74.5

203

249

1200

1175

87.5

89.6

89.5

84.4

82

75.1

32

190.3

111.6

167

220

3600

3525

88.5

91.2

90.9

88.2

86.8

81.8

36

214.2

44.7

168

231

1800

1760

90.2

91.8

91.9

85.3

82.7

75.2

37

204

89.5

197

246

1200

1175

87.5

89.6

90

85.4

83.6

77.6

38

234.3

133.9

178

221

3600

3515

90.2

92.2

92.3

89.5

89.2

86

46

288.4

59.7

178

241

1800

1780

89.5

91.1

90.6

85.7

82.8

75.1

49

267

118.2

163

219

1200

1175

88.5

91

91.4

84.3

82.3

75.5

50

295.9

179.1

179

219

3600

3550

88.5

89.7

88.2

86.7

82.9

76

61

358

74

172

264

1800

1775

90.2

91.4

91

85

81.4

72.8

61

353

147.7

176

233

1200

1175

90.2

92.2

92.6

86.8

85.2

79.4

60

371.8

223.7

193

228

3600

3545

89.5

90.5

89.7

88.7

88.4

85

71

427

88.9

191

266

1800

1775

90.2

92.1

92.1

87.1

85.3

79

71

406

177.5

175

223

1200

1175

89.5

90.9

90.8

86.1

82.9

74.9

73

476.3

268

182

270

3600

3540

89.5

90.9

90.5

88.7

88.4

85

89

541.3

111.2

184

252

1800

1775

91.7

93

93

86.6

84.6

78.3

88

527

222

189

236

1200

1170

89.5

91.2

91.4

88.3

86.8

81.9

89

587.4

336.2

188

273

3600

3535

91

92.5

92.4

89.3

90

88.2

115

663

148.6

184

252

1800

1780

93

93.8

93.5

85

82.6

75.7

119

709.9

295.1

182

216

125

1800

1780

93

93.9

93.8

85.9

83.7

77.1

147

919

369.1

191

221

150

1800

1775

92.4

93.5

93.6

88.9

87.9

83.4

171

1015.6

443.3

163

207

200

1800

1775

94.5

95.4

95.3

88.2

87.2

82.8

225

1219

591.2

150

201

250

1800

1775

94.5

95.2

95.1

87.9

86.8

82.2

282

1725

739.6

153

204

300

1800

1780

94.5

95.5

95.5

89.2

88.9

85.6

333

2200

884.7

0.80

175

350

1800

1780

94.5

95.7

95.8

89.5

89.3

86.2

387

2550

1032.7

80

175

400

1800

1785

95.4

96.1

96.0

90.3

90.3

87.8

435

2856

1176.6

101

248

500

1800

1780

95.4

95.9

95.7

88.6

88.4

85.3

554

3625

1474.7

109

235

600

1800

1770

95

95.9

96.0

89.8

89.5

86.4

659

4733

1780.1

60

175

15

20

25

30

40

50

60

75

100

% OF FULL LOAD

Efficiency and power factor values listed above are typical values. For guaranteed and certified values, refer to the Technical Service Group.
The code letter is an indication of the locked rotor K.V.A in accordance with the National Electrical Code.
When performance values have been quoted, they should be shown on the order.
Data subject to change without prior notice.

www.nidec-motor.com
www.usmotors.com

25

DIMENSION
PRINTS

3/4
LOAD

DRIVE COUPLING
PART NUMBERS

FULL
LOAD

DIMENSION
PRINT INDEX

FULL
LOAD

OPERATING
CHARACTERISTICS

NO
LOAD

LONG TERM STORAGE


INFORMATION

HP

TORQUE AT FULL VOLTAGE (FT.ILBS.)

CURRENT (AMPS)
460 VOLTS

RPM

% EFFICIENCY

% POWER FACTOR

HP

TORQUE AT FULL VOLTAGE (FT.ILBS.)

CURRENT (AMPS)
460 VOLTS

FULL LOAD

LOCKED

PULLOUT

TORQUE @

(STARTING)

BREAKDOWN

FULL
LOAD

LOCKED
STARTING

FULL LOAD
SPEED

NEMA
CODE

NO
LOAD

FULL
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

7.5

1800

1765

90.2

91.9

91.3

86.5

83.2

76.1

61

22.3

230

300

10

1800

1760

90.2

92.2

91.9

87.2

83.8

77.1

11.9

77

29.8

220

280

25

1800

1770

92.4

93.5

93.5

84.2

82

75.3

30

175

74.3

234

233

30

1800

1770

92.4

93.8

93.9

84.5

82.8

76.8

36

201

89.1

225

222

40

1800

1780

93.6

94.3

93.6

87.9

86.6

81.5

46

277

118

190

244

50

1800

1780

93.6

94.5

94.1

87.5

86

80.5

57

344

147.6

185

243

60

1800

1780

94.1

94.7

94.5

87.9

86.6

81.6

68

413

177.3

189

244

75

1800

1775

94.1

95

94.9

87.9

86.5

81.3

85

526

221.7

194

249

100

1800

1780

94.5

95.4

95.2

87.5

86.7

82.6

113

687.5

295.1

176

214

125

1800

1785

95

95.7

95.5

87.1

86

81.4

141

886.4

368.2

178

221

150

1800

1785

95.4

95.7

95.1

86.3

83.6

76.4

171

1063

441.7

169

232

200

1800

1780

95.4

96

95.8

87.7

86.1

80.4

224

1347.2

589.7

167

221

% OF FULL LOAD

VERTICAL
MOTORS
DIMENSION
PRINTS

DRIVE COUPLING
PART NUMBERS

DIMENSION
PRINT INDEX

OPERATING
CHARACTERISTICS

LONG TERM STORAGE


INFORMATION

CONVERSION
CENTER

Operating Characteristics - Vertical HOLLOSHAFT Motors


High Thrust - P Base, Three Phase, Weather Protected Type (WPI), Energy Efficient

Efficiency and power factor values listed above are typical values. For guaranteed and certified values, refer to the Technical Service Group.
The code letter is an indication of the locked rotor K.V.A. in accordance with the National Electrical Code.
When performance values have been quoted, they should be shown on the order.
Data subject to change without notice.

26

www.nidec-motor.com
www.usmotors.com

VERTICAL
MOTORS

Operating Characteristics - Vertical HOLLOSHAFT Motors


High Thrust - P Base, Three Phase, Weather Protected Type (WPI),
Premium Efficient & Premium Efficient/Inverter Duty

CONVERSION
CENTER

RPM

% EFFICIENCY

% POWER FACTOR

FULL LOAD

LOCKED

PULLOUT

TORQUE @

(STARTING)

BREAKDOWN

NEMA
CODE

3/4
LOAD

1/2
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

LOCKED
STARTING

FULL LOAD
SPEED

15

1800

1770

91.7

92

83.4

80.5

72.6

72.6

18.4

108

44.5

227

240

20

1800

1770

92.4

93.3

85.4

84

78.6

78.6

23.7

136

59.4

222

223

25

1800

1765

92.4

93.5

84.6

82.7

76.5

76.5

30

173

74.3

230

230

30

1800

1770

92.4

93.9

84.5

82.8

76.8

76.8

36

201

89.1

224

222

40

1800

1780

94.1

93.6

87.8

86.4

81.3

81.3

45

286

117.9

192

251

50

1800

1780

94.5

94.1

87.7

86.2

80.9

80.9

56

358

147.5

192

252

60

1800

1785

94.5

94.8

87.2

85.9

80.9

80.9

68

434

176.7

200

237

75

1800

1780

95

95.1

85.3

82.9

75.8

75.8

87

539

221.1

200

247

100

1800

1785

95.4

95.1

86.3

84.5

78.4

78.4

114

737.5

294.3

185

230

125

1800

1785

95.4

95.3

86.4

85.2

79.7

79.7

142

924.1

368.1

186

230

150

1800

1785

95.8

95.6

86.3

83.9

77.1

77.1

169

1072.2

441.5

174

235

200

1800

1785

95.8

95.8

85.4

82.4

74.6

74.6

228

1484.2

588.9

186

244

250

1800

1780

95.8

95.6

83.9

80.4

71.8

71.8

292

1794.3

737.1

183

235

300

1800

1785

95.8

96

88.6

88.1

84.4

84.4

331

2200

883.1

80

175

350

1800

1785

95.8

96.5

87.9

87.2

83.2

83.2

389

2550

1031.2

80

175

400

1800

1785

95.8

96.6

96.6

90.2

90.2

87.6

433

2859

1176.6

101

250

450

1800

1785

96.2

96.6

96.3

89.1

88.5

85

491

3250

1323.3

80

250

% OF FULL LOAD

DRIVE COUPLING
PART NUMBERS

FULL
LOAD

DIMENSION
PRINT INDEX

FULL
LOAD

OPERATING
CHARACTERISTICS

NO
LOAD

LONG TERM STORAGE


INFORMATION

HP

TORQUE AT FULL VOLTAGE (FT.ILBS.)

CURRENT (AMPS)
460 VOLTS

DIMENSION
PRINTS

Efficiency and power factor values listed above are typical values. For guaranteed and certified values, refer to the Technical Service Group.
The code letter is an indication of the locked rotor K.V.A in accordance with the National Electrical Code.
When performance values have been quoted, they should be shown on the order.
Data subject to change without prior notice.

www.nidec-motor.com
www.usmotors.com

27

VERTICAL
MOTORS
CONVERSION
CENTER

Operating Characteristics - Vertical HOLLOSHAFT Motors


High Thrust - P Base, Three Phase, Totally Enclosed Fan Cooled (TEFC) Standard Efficient

OPERATING
CHARACTERISTICS

LONG TERM STORAGE


INFORMATION

RPM

DIMENSION
PRINT INDEX

% POWER FACTOR

HP

5
7.5
10
15

NO
LOAD

FULL
LOAD

3600
1800

TORQUE AT FULL VOLTAGE (FT.ILBS.)

CURRENT (AMPS)
460 VOLTS

FULL LOAD

LOCKED

PULLOUT

TORQUE @

(STARTING)

BREAKDOWN

NEMA
CODE

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

LOCKED
STARTING

FULL LOAD
SPEED

3500

80

78.2

73.4

84.3

81.6

75.2

6.9

39.1

7.5

162

267

1745

82.5

84.4

82.5

82.7

77.6

67.9

6.9

45.9

15

240

300

3600

3490

81.5

81.7

78.4

84.1

81

73.4

10.2

63.4

11.3

147

242

1800

1735

84

86.7

85.8

84.7

80.9

72.6

9.9

62

22.7

254

299

3600

3485

82.5

84.3

81.9

87.3

83.6

76.9

13

80.8

15.1

157

253

1800

1740

85.5

88

87.3

84.2

79.5

71

13

80.8

30.2

230

270

3600

3470

86.5

87.8

86.4

88

87.1

83.1

18.5

108.2

22.7

168

253

G
G

% OF FULL LOAD
G

1800

1765

88.5

89.1

87.8

83.7

79.6

70.4

19

113

44.6

210

270

20

1800

1760

87.5

89.9

89.4

85.6

83.2

76.2

24.7

135

59.7

193

242

25

1800

1760

89.5

90.7

90.2

85.9

83.5

76.6

30

179

74.6

210

250

30

1800

1755

88.5

90.8

90.7

86.2

83.9

77.2

37

212

89.7

200

250

40

1800

1765

90.2

91.4

90.7

87.4

85.7

80

48

264

118.9

179

229

50

1800

1765

91

92.3

91.8

88.1

86.9

82.2

58

335

148.6

188

232

60

1800

1775

91.7

92.3

91.4

86.6

85.4

80.3

71

392.7

177.4

163

200

75

1800

1775

92.4

93

92.3

86.8

85.7

81

88

505.9

221.7

170

205

100

1800

1780

93

93.1

91.6

85.5

82.5

75.1

118

746.8

294.7

171

242

125

1800

1780

92.4

92.3

90.8

88.4

86.8

81.6

143

975.7

369

164

264

DIMENSION
PRINTS

DRIVE COUPLING
PART NUMBERS

% EFFICIENCY

Efficiency and power factor values listed above are typical values. For guaranteed and certified values, refer to the Technical Service Group.
The code letter is an indication of the locked rotor K.V.A in accordance with the National Electrical Code.
When performance values have been quoted, they should be shown on the order.
Data subject to change without prior notice.

28

www.nidec-motor.com
www.usmotors.com

VERTICAL
MOTORS

Operating Characteristics - Vertical HOLLOSHAFT Motors


High Thrust - P Base, Three Phase, Weather Protected Type (WPI), International Duty

CONVERSION
CENTER

RPM

% EFFICIENCY

% POWER FACTOR

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

20

1800

1770

90.2

91.3

90.5

25

1800

1770

89.5

90.1

89.2

30

1800

1765

91

91.8

40

1800

1770

91

50

1800

1775

60

1800

1770

75

1800

1770

100

1800

125

PULLOUT

(STARTING)

BREAKDOWN

NEMA
CODE

3/4
LOAD

1/2
LOAD

FULL
LOAD

LOCKED
STARTING

FULL LOAD
SPEED

82.9

78

67.7

26.2

175

59.3

230

300

79.5

72.8

60.3

34

221

74.3

233

301

91.3

82.4

77.6

67.1

39

254

89.2

230

290

92

91.2

84.5

81.2

73

51

294

118.6

180

237

91

92.3

91.6

84

78.7

69.1

64

400

148.1

210

266

91.7

92.9

92.5

85.5

82.8

75.3

75

466

177.8

200

256

91

92.9

92.7

84.9

81.4

73.1

95

607

222.4

210

266

1780

93

93.7

93

81.8

77.6

68

129

831.3

295

205

244

1800

1780

93.6

93.9

93.2

80.9

76.1

65.9

162

1143.4

368.5

228

267

150

1800

1780

92.4

93.4

93.2

87.3

84.6

77.4

182

1241.2

442.6

198

239

200

1800

1780

93

93.9

93.8

85.1

81.2

71.9

247

1807.7

589.7

157

281

250

1800

1780

95

95.7

95.7

87.7

85.3

78.8

294

2057.9

738.2

150

271

300

1800

1780

95

95.9

95.8

90.3

89.8

86.9

341

2203

885.9

90

200

% OF FULL LOAD

DIMENSION
PRINT INDEX

FULL
LOAD

LOCKED

TORQUE @

OPERATING
CHARACTERISTICS

NO
LOAD

FULL LOAD

LONG TERM STORAGE


INFORMATION

HP

TORQUE AT FULL VOLTAGE (FT.ILBS.)

CURRENT (AMPS)
460 VOLTS

DRIVE COUPLING
PART NUMBERS
DIMENSION
PRINTS

Efficiency and power factor values listed above are typical values. For guaranteed and certified values, refer to the Technical Service Group.
The code letter is an indication of the locked rotor K.V.A in accordance with the National Electrical Code.
When performance values have been quoted, they should be shown on the order.
Data subject to change without prior notice.

www.nidec-motor.com
www.usmotors.com

29

VERTICAL
MOTORS
CONVERSION
CENTER
LONG TERM STORAGE
INFORMATION
OPERATING
CHARACTERISTICS
DIMENSION
PRINT INDEX
DRIVE COUPLING
PART NUMBERS

Operating Characteristics - Vertical Solid Shaft


Normal Thrust - P Base, Three Phase, WPI & TEFC, Energy Efficient
Energy Efficient
RPM

% EFFICIENCY

% POWER FACTOR

HP
NO
LOAD

FULL
LOAD

FULL
LOAD

1800

1745

82.5

1200

1150

80

3600

3495

82.5

1800

1745

84

1200

1180

85.5

3600

3490

1800

1735

1200
3

1.5

3/4
LOAD

CURRENT (AMPS)
480 VOLTS

CURRENT (AMPS)
FULL LOAD
TORQUE @

LOCKED
(STARTING)

PULLOUT
BREAKDOWN

NEMA
CODE

1/2
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

LOCKED
STARTING

81.9

78.4

76.1

67.5

54.3

1.5

11.3

324

418

82.5

80.4

72

63.4

50.2

1.6

9.3

4.6

250

335

82

78.8

87.6

83

73.6

1.9

16.7

2.3

277

378

84.6

82.2

81.3

74.4

62.2

2.1

17.5

4.5

343

437

86

83.3

64.9

56.1

43.5

2.5

16.5

6.7

221

354

84

84.2

81.9

90.2

86.8

79

2.5

21.9

280

377

84

84.6

82.2

78.7

70.4

57

2.8

23.3

359

445

1180

86.5

87.3

84.7

68.3

59.7

46.7

3.1

21.9

8.9

233

371

1800

1755

87.5

87.5

85.5

78.7

71.6

59.1

4.1

31

284

392

FULL LOAD
SPEED

% OF FULL LOAD

1800

1740

87.5

89.1

88.8

84.3

79.6

69.6

6.3

42

15.1

235

322

7.5

1800

1750

89.5

90.3

89.4

84.6

81.2

73.4

9.3

57

22.5

228

285

30

1800

1765

92.4

93.3

93.1

85.1

83.3

77.2

36

210

89.2

230

228

DIMENSION
PRINTS

Premium Efficient
RPM

% EFFICIENCY

% POWER FACTOR

HP

1.5

CURRENT (AMPS)
480 VOLTS

CURRENT (AMPS)
FULL LOAD
TORQUE @

LOCKED
(STARTING)

PULLOUT
BREAKDOWN

NEMA
CODE

NO
LOAD

FULL
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

LOCKED
STARTING

1800

1755

85.5

84.4

80.9

76.8

68.8

56.2

1.4

13.5

412

523

1200

1165

82.5

82.5

76.6

62.7

52.9

40.4

1.8

13

4.5

363

478

3600

3510

84

84

79.9

89.3

85.6

77.7

1.9

18.8

2.2

326

437

1800

1755

86.5

86.5

83.8

81.2

74.2

62.1

19.9

4.5

387

509

1200

1175

87.5

87.5

85.6

71

63.4

50.7

2.3

14.2

6.7

188

317

3600

3505

85.5

85.5

82.6

90.4

87.1

79.8

2.4

25.2

341

446

1800

1750

86.5

86.5

84.9

81.9

75.1

62.8

2.6

25.2

379

488

1200

1175

88.5

88.5

86.4

71.5

63.9

51.1

20

8.9

211

340

FULL LOAD
SPEED

% OF FULL LOAD

Efficiency and power factor values listed above are typical values. For guaranteed and certified values, refer to the Technical Service Group.
The code letter is an indication of the locked rotor K.V.A in accordance with the National Electrical Code.
When performance values have been quoted, they should be shown on the order.
Data subject to change without prior notice.

30

www.nidec-motor.com
www.usmotors.com

VERTICAL
MOTORS

Operating Characteristics - Vertical Solid Shaft


Normal Thrust - P Base, Three Phase, WPI & TEFC, Premium Efficient

CONVERSION
CENTER

% EFFICIENCY

% POWER FACTOR

HP

CURRENT (AMPS)
480 VOLTS

CURRENT (AMPS)
FULL LOAD
TORQUE @

LOCKED
(STARTING)

PULLOUT
BREAKDOWN

NO
LOAD

FULL
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

3/4
LOAD

1/2
LOAD

FULL
LOAD

LOCKED
STARTING

FULL LOAD
SPEED

1800

1755

86.5

87.7

85.6

78.6

71.5

59

4.1

31

284

392

NEMA
CODE

% OF FULL LOAD

LONG TERM STORAGE


INFORMATION

RPM

87.5

89.3

88.9

84.6

80

70.3

6.3

41

15.1

231

317

1750

88.5

90.4

89.5

84.7

81.2

73.4

9.3

57

22.5

228

285

10

1800

1750

89.5

90.9

90.7

85.7

83

76.3

12.2

70

30

211

262

15

1800

1775

91

92.1

91.3

83.3

80.2

72.2

18.4

107

44.4

227

236

20

1800

1770

91

92.4

91.9

82.5

79.4

71.2

25

141

59.4

223

227

25

1800

1770

91.7

93.4

93.2

82.4

79.1

70.7

31

174

74.2

231

234

30

1800

1770

92.4

94.3

94.4

85

83.2

76.9

36

210

89

230

228

40

1800

1780

93

93.7

93.3

84

80.2

71

48

289

118.1

181

251

50

1800

1775

93

94.3

94.2

85.8

83.3

76

59

351.4

147.8

172

234

100

1800

1780

95

95.7

95.8

87.6

86.8

82.7

113

684.4

294.9

174

213

125

1800

1780

94.5

95.9

96

87.4

87.2

83.8

141

878.6

369.3

165

200

DRIVE COUPLING
PART NUMBERS

1740

1800

DIMENSION
PRINT INDEX

1800

OPERATING
CHARACTERISTICS

5
7.5

DIMENSION
PRINTS

Efficiency and power factor values listed above are typical values. For guaranteed and certified values, refer to the Technical Service Group.
The code letter is an indication of the locked rotor K.V.A in accordance with the National Electrical Code.
When performance values have been quoted, they should be shown on the order.
Data subject to change without prior notice.

www.nidec-motor.com
www.usmotors.com

31

Das könnte Ihnen auch gefallen