Testing for Z quality steel


Share Share Tweet 0 0

The term Z quality has been used for many years. It is often specified for critical applications in structures such as offshore oil and gas platforms (particularly the node joints), ball mills, heavy flanges and some pressure vessels. These applications endure high levels of stress from loading or from excessive restraint of welded sections, particularly where heavy plate sections are used. what does Z quality actually mean? means a low-sulfur steel with a tested level of ductility through the z axis of the plate, as opposed to the transverse or longitudinal axes. Z quality is determined by through thickness testing, hence Z quality plate is sometimes referred to as through thickness tested plate. Z quality is usually specified where the chief design concern is high loads perpendicular to the plate surface. Plate thicknesses between 16 and 100 mm can be Z tested. applications such as the nodal joints of an offshore structure, Z testing ensures the plate can cope with large through thickness tensile forces. The Z test is a tensile test conducted perpendicular to the surface of the plate. It specifically measures ductility rather than strength. In effect, the test replicates the forces involved in pulling the two faces of a plate apart. Testing Much of the work in Z testing goes into preparing the sample. In the case of BlueScope Steels XLERPLATE steel, for instance, a cylindrical plug of steel is taken from a sample of the steel. Next, in order to provide a test piece long enough to fit the tensile testing machine, stubs are welded to the ends of the cylinder (the former plate surfaces) using flash butt welding. The test piece is then machined into the appropriate for a tensile test. Welding of the stubs onto the test piece limits the thickness of plate that may be Z tested, as the heat from the welds leads to changes in the plate'microstructure. If the plate is too thin, a large proportion of the sample will be s affected and this can impact on the result obtained in the through thickness test. Hence, a minimum plate thickness of 16 mm is set to ensure a valid test result. Z test is carried out in the same manner as a tensile test except that, as already stated, it measures ductility (% reduction in cross-sectional area of the test piece), not strength. In order to ensure consistent Z test performance, it is common to perform a minimum of two tests on each plate. Calculations Z testing, the percentage reduction in cross-sectional area, or RAz, is the required measure. obtain the RAz figure, the cross-sectional area after testing (Rf) is deducted from the cross-section before testing (Ro) and the result is expressed as a percentage of the original cross-section: (RAz = (Ro - Rf) / Ro x 100). Therefore, a higher RAz figure represents a greater percentage reduction in cross-section before failure. This in turn reflects greater ductility of the steel in the Z direction, as the steel will deform to a greater extent prior to failure. Through thickness test requirements are detailed in Australian Standards AS/NZS 3678 and AS 1548. Most specifications for Z grade steel will require a certain minimum RAz figure, generally in the order of 15, 25 or 35%. These figures have been determined from practical experience. The required RAz figures are commonly incorporated into the grade name of through thickness steels, particularly for pressure vessels, such as AS1548-PT460NRZ25. In this example, the specification is calling for AS1548-PT460NR, tested to a minimum requirement of % reduction in area in the through thickness direction. Producing Z quality XLERPLATE steel Clearly, not just any XLERPLATE steel will pass the Z test. The key to producing Z quality plate lies in two factors. Firstly, it must have low sulfur, and secondly, there must be sufficient reduction during the rolling process. Low sulfur ordinary structural steels, the typical sulfur level is enough to form sulfides of a size that can lead to failure when subjected to very high stresses in the Z direction. Hence, it is necessary to restrict the sulfur level where Z quality is required. BlueScope Steel restricts sulfur levels to less than 0.005% for Z quality XLERPLATE steel grades. This requires extra processing during steelmaking, specifically adding calcium which has a particular affinity for sulfur. The resulting sulfides are floated off with the slag. At BlueScope Steel, this process is generally combined with vacuum degassing to ensure the steel is as clean as possible. It is essential that specifiers discuss with steel suppliers the specific requirements of the Z quality steel to be used. Rolling reduction Once a suitable low-sulfur steel has been developed, the other requirement for Z quality is high reduction during rolling, generally a minimum reduction of 3:1. This limits the maximum thickness of Z quality steel to one third of the slab thickness available. High reduction rates ensure that any sulfides present are rolled out to such an extent that they are broken up and as a result do not form the plane of weakness. However, the steel must be suitably low in sulfur for this process to work. With standard slab thickness at 230 mm, this limits the plate thickness to about 75 mm. However, Z quality XLERPLATE steel with thicknesses up to 100 mm is available from 300 mm thick slabs for a limited range of products. John Dryden, National Technical Manager (Uncoated), BlueScope Steel

Related Articles
National OHS harmonisation: will it arrive? GE believes Australian carbon tax ' courageous and gutsy' SA leads the states in wind energy AGL Energy to build gas-fired power plant in Victoria Coal company fined for water pollution twice in three weeks

Recent News
NI and UniMAP collaborate to advance engineering and robotics education ANCA Motion - exporting from Bayswater North to the world Invensys and Valero sign licensing agreement for ACA.HF Solution Cogita sells ANZ ERP business to Epicor CompAir launches dedicated Custom Engineered Products division 2012 Westwick-Farrow Pty Ltd. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Use of this website constitutes acceptance of our Terms and Conditions and Privacy Policy.
Search ...

Network Sites

Topics Tweets

Pneumatics & hydraulics Business Wireless Factory automation Software & IT Industrial networks & buses Process control systems http://www.processonline.com.au/articles/41900-Testing-for-Z-quality-steel Safety

6/1/2012 9:39:36 AM

Das könnte Ihnen auch gefallen