Basic concept of grounding in the accelerator ring Cabling and grounding in the RCS Cabling and grounding in the main ring Cabling and grounding of injection/extraction pulse power system Grounding and shielding of RF system Ceramic breaks of the main ring Noise immunity reinforcement plan of beam monitors
Neutral point
Magnets
To Chokes
capacitor
Dipole magnet
Ceramics vacuum duct installed in dipole magnet Ceramics duct is installed in every dipole and quadrupole magnets.
GROUNDING CONNECTION OF QUADRUPOLE AND SEXTUPOLE MAGNETS Earth Cable are separately fed by each magnet family and has open end symmetrically.
Q**,S ++
QFP,SDB
Potential 0
Potential 0
BM1
BM
Building D1
BM 6
BM 3
BM 4
Building D2
PULSE MAGNET POWER SUPPLY FOR INJECTION AND EXTRACTION SYSTEM Coils are not grounded in the tunnel but grounded in power supply buildings through power cables. Magnetic core, vacuum duct, and frame are grounded both in the tunnel and buildings. Each grounding points are connected by cables.
Vacuum Chamber
400mm2
400mm2
PULSE MAGNET POWER SUPPLY FOR A KICKER SYSTEM Outer conductor of a coaxial cable is connected to frames at both end. Magnetic core, vacuum chamber, and frame are grounded in a tunnel, also grounded in a building through the coaxial cable.
HV PS
In general, grounding is designed so that drive current must directly return to each corresponding power supply. 1.2MW anode power supplies are switched mode power supply w/ IGBT inverters. Tri-axial cable for tube anode supply is used for shielding high frequency EMI noise. Single point grounding is performed. However, cavity /amplifier chassis are grounded w/ resistor for safety
ARC section (#1,#2, #3): Breaks at an upper stream point of each bending magnet
Example: induced noise on the cable under noisy environment with a switching power supply outer conductor RG58 c/u: copper braid wire ( 5 m) S04272B: longitudinal metal foil ( 4 m )
DC
10MHz
The shielding of coaxial cables are connected to the beam pipe via connectors.
ch.1&2 ch.3&4 Connection to the GND depends on noise observation. noise cut trans.
SUMMARY
EMC program of the accelerator ring is mainly focused on grounding. Two golden rules of grounding are one point grounding and safety. Power supply, beam pipes, vacuum pumps are grounded separately. Grounding of cable rack is under consideration. As to beam monitors, high efficiency shielding cables are selected