Functional Requirements for Fiscal Metering Systems
Finished by
LGM
Document
Functional Requirements version 1.5 final.doc
Date, version
October 2010, 1.5
Characteristic
LGM 05.008
Status
Final

Functional Requirements
for
Fiscal Metering Systems



GAS TRANSPORT SERVICES
Page 2 of 20

Functional Requirements for Fiscal Metering Systems




General introduction
Natural gas in the Netherlands is transported between entry and exit points. At these points
accountable measurements are needed for billing purposes. There is a set of minimum
requirements that newly build or renovated connections to the GTS network shall comply
with, before the metering system can be used for the purpose of custody transfer of gas.

This document describes the minimum requirements to which the used measuring
equipment, calibration equipment, calibration materials, calibration procedures, and
maintenance procedures shall comply. These requirements include the accompanying
uncertainty and the data handling. The total metering system shall comply with the
international accepted standards and the national legislation for energy determination.
Final details concerning above-mentioned items shall be agreed upon by the Metering
Department of GTS and laid down in the Metering Manual, to be drawn by the operator.



Definition list
Measuring installation: Assembly which comprises the meter(s) and, where
applicable, any additional devices and associated
measuring instruments
Metering system: A metering system encloses all components at the
measuring installation and the corresponding (remote)
data handling systems, needed for the determination of
energy amounts for billing purposes or controlling of
other contract parameters.
Data handling: The data handling is the handling of measuring data
needed for on-line allocation and off-line allocation.
Telemetry data and other operational data is not
included is the above mentioned data handling.
Owner: The Owner is the party to which the metering system
belongs and who is responsible for the metering
system.
Measuring installation operator: Natural or legal person who is responsible for the
operation and maintenance of the measuring
installation. Note: the measuring installation operator is
referred to be the "operator
Accountable data: Accountable data is the approved measuring and
allocation data, which the owner of the metering
system has sent to GTS, after it has been verified
and/or corrected and finally approved.





GAS TRANSPORT SERVICES
Page 3 of 20

Functional Requirements for Fiscal Metering Systems




Contents
General introduction.................................................................................................... 2
Definition list.............................................................................................................. 2
Specifications of the metering system............................................................................ 4
1. Overall metering system................................................................................... 4
2. Flow measurement........................................................................................... 5
3. Volume conversion........................................................................................... 6
4. Flow computer, pressure transmitter and temperature transmitter......................... 6
5. Fuel gas measurement ..................................................................................... 6
6. Gas Chromatograph ......................................................................................... 7
7. Quality Measurement ....................................................................................... 7
8. Data Transmission/Reporting ............................................................................ 8
9. Reference instruments, equipment and materials................................................. 8
10. References to applicable standards..................................................................... 9
APPENDIX 1: Uncertainty Modelling............................................................................. 11
Numerical example ............................................................................................... 17
APPENDIX 2: Long Term Effects, "CUSUM ................................................................... 19




GAS TRANSPORT SERVICES
Page 4 of 20

Functional Requirements for Fiscal Metering Systems




Specifications of the metering system
1. Overall metering system
The Parties with connection to the GTS network shall inform GTS in the design of a newly
build or renovated measuring installation by sending on time the P&IDs (piping and
instrumentation diagrams) and PFDs (Process Flow Diagrams). GTS shall react on these
documents within a month. Only after agreement with GTS the measurement system can be
actually be modified or built.

The owner of the metering system has the responsibility to make the accountable
measurements compliant with the applicable (legal) requirements and the latest
international standards (CEN, ISO, OIML). See chapter 10 for the applicable
standards. The total metering system shall comply with the requirements and the
recommendations of EN 1776.
The overall uncertainty on energy shall not exceed 0.75%. (For the definition and an
example as used by GTS see APPENDIX 1: Uncertainty Modelling)
The owner of the metering system shall prove that the operational uncertainty is
within limits by using an uncertainty model and ISO 7871. (APPENDIX 2: Long Term
Effects, "CUSUM).
The measuring policy shall assure that systematic errors are actively reduced using
agreed procedures regardless of the sign of the deviation. When afterwards a
systematic error is found in the energy determination over a period of time (e.g.
caused by incorrect settings or deviations of instruments outside the agreed limits),
the system shall be capable to deliver all the required data to calculate the deviating
amount of energy (for the purpose to be presented to GTS and to be settled with the
interested parties).
All parameters of the metering system shall be fully transparent to GTS.
All measurements shall be traceable to international (reference) standards (BIPM;
ISO 17025).
The degree of transparency on data, quality assurance and instrument maintenance
shall be agreed upon and shall be established in a Metering Manual. This Metering
Manual consist among others of:
o The calibration procedures for P, T, flow meter, gas chromatograph and
flow computer, including tolerances and actions.
o The quality control, periodical and overall check, at which all instruments
are calibrated using measuring references, except for the flow meter.
o Used (reference) materials and performance registration (Quality
Assurance).
o The data handling including verifications, corrections and final approval
of the measuring data.
The instruments shall be used within their calibrated range.
The required availability for the measuring installation is 99.9%. This can be
managed by using redundancy in the systems (e.g.: n+1 meter runs, double GC
system, No-break power). Gas shall only flow if the measuring installation is
available and is functioning within specifications.
For large volumes (> 250 million m3 per year per meter run) a double fitted flow
measuring installation in series of different measuring principles shall be used. For
the quality measurement double fitted gas chromatographs shall be used for the
total measurement installation, including separate sample conditioning, carrier gas,


GAS TRANSPORT SERVICES
Page 5 of 20

Functional Requirements for Fiscal Metering Systems




calibration gas and reference gas.
In case of a double fitted flow measuring installation the energy determination shall
be based on the average value of both measurements.
A double fitted measuring installation shall be equipped with on-line comparison
between the GCs (Hs) and flow meters (Vn) with relevant alarms on the calculated
deviations.

2. Flow measurement
The equipment used shall have a formal approved status or dispensation by a
notified body and shall have a MID approval.
Flow meter shall be mounted according to the standards referred to in chapter 10.
An upstream flow conditioner shall be used; the same flow conditioner and the same
upstream pipe of the flow meter shall be used during calibration. The distance
between the flow conditioner and the gasmeter shall be at least 10 diameters. The
manufacturer of the gas meter shall have documented evidence that the gas meter
has a good performance with the flow conditioner at the chosen distance. If a flow
conditioner is not used, the owner has to prove that there is no installation effect on
the flow measurement.
Flow meters shall be protected against pollution or dirt.
Active interpretation of diagnostic data of a flow meter must be used if present, for
example a comparison of Speed of Sound (SOS) when using an US meter: SOS
derived from GC data versus SOS measured by US (additional information can be
obtained from GTS).
The meter run shall be sufficiently thermally insulated from ambient temperature.
Calibration curve correction shall be applied to minimize systematic errors (using the
physical reference points of the calibration).
Recalibration (as found) shall be done at least every 5 years.
Every primary meter shall have an individual calibration certificate and the
calibration shall be performed complying to the following requirements:
o Calibration of the flow meters will be performed at an internationally recognised
calibration site that is accredited by the national councel of accreditation
according to ISO 17025 and holds the Harmonized European Gas Cubic Meter for
natural gas as realized by PTB, NMI-VSL and BNM. Owner will inform GTS at
which facility the flow meters will be calibrated. At least 1 month in advance
owner will inform GTS when the flow meters will be calibrated.
o Using natural gas under operational pressure.
o The conditions at flow calibration shall resemble the conditions during operation.
All parameters that may adversely affect the performance of the meter shall be
considered: wall roughness (coating), temperature, diameters steps, protrusions,
bends, flow conditioners etc. All generally recognized differences between the
conditions at flow calibration and conditions during operation shall be eliminated
if these differences result in a significant shift of (part of) the calibration curve.
Therefore the flow meter, the relevant upstream piping and the flow conditioner
shall be calibrated as a package.
o Calibration at least at 6 flow set points conform the OIML requirements
(R137)(Qmin, 10, 25, 40, 70 and 100% of Qmax).
o Bi-directionally used flow meters are to be calibrated bi-directionally which
results in the appropriate certificates for each direction.
o The flow meters shall be adjusted such that the weighted average deviation is as


GAS TRANSPORT SERVICES
Page 6 of 20

Functional Requirements for Fiscal Metering Systems




close as possible to zero.
o After adjustment, the flow meter deviations at all the calibrated flow points shall
be less than the maximum permissible deviation (MPD) specified in Table 1.
(NB:These deviations are still without curve corrections).
o Linearity and steepness of the curve: The errors in the flow rate range between
0.2Qmax and Qmax shall be within a band of 0.3%.

Table 1 MPD flow meters
Flow rate MPD
%
Qmin Q <
0.2Qmax
1
0.2Qmax Q
< Qmax
0.5


3. Volume conversion
Volumes at operational conditions shall be converted to volumes at normal conditions
(273.15 K and 1.01325 bara) and to energy. Volume conversion shall be performed
continuously by using live inputs of absolute pressure (P), temperature (T) and
compressibility (Z). Compressibility (Z) shall be calculated by using ISO 12213 with live
inputs of P, T and gas composition. Energy conversion shall be performed by using live input
of the calorific value.

4. Flow computer, pressure transmitter and temperature transmitter
The flow computer, pressure transmitter and temperature transmitter shall have a MID
approval, and mounted according to the relevant standards. Pressure shall be measured with
an absolute pressure transmitter or with a gauge pressure transmitter and an atmospheric
pressure transmitter. Ambient influences such as temperature, pressure, noise, moisture,
pulsations, sunlight etc. must be minimized.

The volume conversion shall meet the following requirements:
Application of Z calculation according to ISO 12213
Full traceability of actions by electronic logging.
Use of transparent logical decisions (alarm handling, low flow).
The inputs shall be digital (serial) to eliminate additional uncertainty by transmission
techniques (like analogue transmission).
Measured volumes shall be registered by using non-volatile counters. Counters shall
be installed for volume at operational conditions, volume corrected for the calibration
curve, volume at normal conditions and energy. Bi-directional systems shall be
equipped with the above mentioned counters for each direction.
Preferably use of one (1) flow computer per primary instrument.

5. Fuel gas measurement
All fuel gas shall be measured correctly with a corresponding flow computer. Attention must
be paid to the position of the fuel gas measurement in relation to the gas chromatograph and
the meter runs and to the state of the measuring installation (stand-by, flow or no flow).


GAS TRANSPORT SERVICES
Page 7 of 20

Functional Requirements for Fiscal Metering Systems






6. Gas Chromatograph
A Gas chromatograph shall comply with the following requirements:
Type approval by authorized body.
Mounted according to relevant standards.
Minimization of ambient influences such as temperature, pressure, noise, moisture,
pulsations, sunlight etc.
Authorized access only.
The gas chromatograph (GC) shall be operated according to the following points:
o The GC shall be used according ISO 6974.
o The calculation of the physical components like calorific value, wobbe,
density and relative density shall be according ISO 6976, table 3, 25C.
o A sampling system shall ensure that gas sample is representative to the
gas in the gas station regarding composition and conditions and time. A
fast loop must be used if the delay time is too long to comply with the
above requirement (See the reference to ISO 10715 in Chapter 10).
o The GC should analyse all components with an influence > 0.01% on the
calorific value.
The use of the pseudo component "C6+ for higher hydrocarbons
(like C6s, C7s, Benzene) is allowed only if the subdivision is
constant in time. This shall be demonstrated by analysing spot
samples.
The use of a fixed component (e.g. Helium if it is used as carrier
gas) is allowed if the concentration is constant in time. This shall
be demonstrated by analysing spot samples.
o The uncertainty of the GC shall be demonstrated according to the
Performance Evaluation ISO 10723. From this evaluation a decision shall
be made, in accordance to the expected gas composition range, if a
multi-level calibration is necessarily.
o The GC shall be periodically tested by analysing a certified natural gas,
which resembles the process gas. Frequency will be agreed between GTS
and the owner and will be established in the Metering Manual.
o It shall be demonstrated that the GC will function within the stated
uncertainty of the Uncertainty Modelling (see Appendix 1) by using a
reference gas (natural gas, monthly basis) and a calibration gas
(synthetic gas) to monitor Hs, density and individual components.
Frequency will be agreed upon between GTS and the owner and will be
established in the Metering Manual.


7. Quality Measurement
The sampling system shall ensure that the gas sample is representative for the gas
in the line considering composition and conditions (ISO 10715).
All measurements shall be traceable to international standards.
Parties shall mutually agree on frequency and method of analysing the following
components and physical properties: Potential Hydrocarbon Liquid Content, Water
Dewpoint, Hydrogen Sulphide, Total Sulphur, Wobbe, Calorific Value, Oxygen,


GAS TRANSPORT SERVICES
Page 8 of 20

Functional Requirements for Fiscal Metering Systems




Carbon dioxide etc.
Parties shall mutually agree on calibration procedures, (reference) materials and
performance registration (Quality Assurance) and will be established in a separate
non-fiscal Measuring Manual


8. Data Transmission/Reporting
The following data and reports shall be provided by the owner of the measuring station:
On-line data: Energy and volume counters (GJ and m3n) at 5 minutes interval using
VPN per meter and flow direction. Data transmission is described in Exhibit D of the
GCA: "NIMBUS-IM XML interface for Gas suppliers and is available at Gas Transport
Services.
Accountable data at monthly basis: hourly values of accountable energy, normal
volume and caloric value per meter run on monthly basis using XML formatted file
transfer over IP. The requirements for sending data are described in Exhibit P of the
GCA: "Requirements for sending data to Gas Transport Services. In the same
Exhibit P the definition of the message is described in "Definition PROD MINFO
envelope. Both documents are available at Gas Transport Services.
On request: all primary, hourly, data relevant to the accountable figures (e.g. Vb,
Vbc, Vn, E, P, T, Hs, per meter) including applied corrections.
Calibration results + agreed annual Performance Overview.

Failures in the on-line data communication (NIMBUS-IM) must be repaired by each party
as soon as possible, with a maximum of 24 hours.

9. Reference instruments, equipment and materials.
Reference materials like test and calibration gasses and calibration equipment (reference
instruments) shall be used to check the gas chromatograph, pressure and temperature
transmitters and flow computers. Reference materials and equipment:
Shall be fit for the purpose (regarding range, uncertainty etc.)
Shall be certified by a notified body or traceable to international standards.
Shall have a valid calibration certificate with stated reference uncertainty and
established deviations.
The recalibration period as established by the notified body will be respected.





GAS TRANSPORT SERVICES
Page 9 of 20

Functional Requirements for Fiscal Metering Systems




10. References to applicable standards

Code Name Date/version
EN1776 Gas supply systems - Natural gas measuring
stations - Functional requirements
DIN EN 1776 (1999-
06)
ISO/TR
7871
Cumulative sum charts - Guidance on quality
control and data analysis using CUSUM
techniques
ISO/TR 7871:1997
ISO
9951
Measurement of gas flow in closed conduits -
Turbine meters
ISO 9951:1993/
Cor 1:1994
NEN EN
12261
Turbine gas meters NEN-EN
12261:2002/A1:2007
ISO
17025
General requirements for the competence of
testing and calibration laboratories
ISO/IEC 17025:2005
Cor 1:2006
ISO
17089
Measurement of fluid flow in closed conduits -
Ultrasonic meters for gas
part 1: Meters for custody transfer and
allocation measurement

Draft version:
25-11-2009
ISO
12213
Natural gas - Calculation of compression factor
-
Part 1: Introduction and guidelines
Part 2: Calculation using molar composition
analysis
Part 3: Calculation using physical properties

ISO 12213-1:2006
ISO 12213-2:2006
ISO 12213-3:2006
ISO
6974
Determination of composition with defined
uncertainty by gas chromatography
Part 1: Guidelines for tailored analysis
Part 2: Measuring-system characteristics and
statistics for processing of data
Part 3: Determination of hydrogen, helium,
oxygen, nitrogen, carbon dioxide and
hydrocarbons up to C
8
using two packed
columns
Part 4: Determination of nitrogen, carbon
dioxide and C
1
to C
8
and C
8
+ hydrocarbons
using for a laboratory and on-line measuring
system using two columns
Part 5: Determination of nitrogen, carbon
dioxide and C
1
to C
8
and C
8
+ hydrocarbons
using for a laboratory and on-line measuring
system using three columns
Part 6: Determination of hydrogen, helium,
oxygen, nitrogen, carbon dioxide and C
1
to C
8

hydrocarbons using three capillary columns


ISO 6974-1:2000
ISO 6974-2:2001

ISO 6974-3:2000


ISO 6974-4:2000



ISO 6974-5:2000



ISO 6974-6:2002


ISO
6976
Calculation of calorific values, density, relative
density and Wobbe index from composition
ISO 6976:1995/
Cor 3:1999


GAS TRANSPORT SERVICES
Page 10 of 20

Functional Requirements for Fiscal Metering Systems




ISO
6570
1

Natural gas -- Determination of potential
hydrocarbon liquid content -- Gravimetric
methods
ISO 6570:2001
ISO
6326
(or ISO
19739)



Natural gas -- Determination of sulfur
compounds Part 1: General introduction
Part 3: Determination of hydrogen sulfide,
mercaptan sulfur and carbonyl sulfide sulfur by
potentiometry
Part 5: Lingener combustion method

Natural gas -- Determination of sulfur
compounds using gas chromatography


ISO 6326-1:2007
ISO 6326-3:1989

ISO 6326-5:1989

ISO 19739:2004/Cor
1:2009

ISO
10715
Natural gas -- Sampling guidelines ISO 10715:1997
OIML
R137
Gas meters
Part 1: Requirements
OIML R 137-1
Edition 2006 (E)


1
) An alternative for the measuring method described in ISO 6570 is the use of a chilled mirror hydrocarbon
dew point instrument. However, such a hydrocarbon dew point instrument needs to meet certain requirements and
shall be calibrated periodically using a specific procedure. Both requirements for the hydrocarbon dew point
instrument as well as the calibration procedure are described in ISO TR 12148 `Natural gas - Calibration of chilled
mirror type instruments for hydrocarbon dew point (liquid formation) the requirements


GAS TRANSPORT SERVICES
Page 11 of 20

Functional Requirements for Fiscal Metering Systems




APPENDIX 1: Uncertainty Modelling

Model description

The uncertainty model is based on a number of assumptions and definitions. These will be
given first.

Definitions

The definitions used are in based on the International Vocabulary of Basic and General Terms
in Metrology [2]. The numbers refer to the definition number in this document.
With each term a short clarification or interpretation is given.


Uncertainty Parameter, associated with the result of a measurement, that
characterises the dispersion of the values that could reasonable be
attributed to the measurand (3.9)
For practical purposes, the uncertainty is taken to be twice the
standard deviation of a distribution. Also, the probabilities are assumed
to be normally distributed. This implies that there is a 95% probability
to remain within the uncertainty boundaries and that values are
distributed symmetrically around the expectation value.

True value Value consistent with the definition of a give particular quantity (1.19)
This is the value that is obtained by a perfect measurement. It is not
possible to determine the true value exactly. For this purpose, the
'conventional true value is sometimes introduced, having an accepted
uncertainty.

Error Result of the measurement minus the true value of the measurand
(3.10)
Since the true value is not exactly known, the error can only be
determined within certain confidence limits.

Reference Standard Standard, generally having the highest metrological quality available at
a given location or in a give organisation, from which measurements
are derived (6.6)
The term 'reference will also be used. The reference is taken to be the
instrument or system used for calibration, representing the true value
with specified uncertainty. It is assumed that the reference has zero
systematic error, or that the systematic error is known so it can be
compensated for.

Calibration Set of operations that establish, under specified conditions, the
relationship between values of quantities indicated by a measuring
instrument or measuring system, or values represented by a material
measure or a reference material, and the corresponding values realised
by standards (6.11)
In a calibration the difference between the measured value and the


GAS TRANSPORT SERVICES
Page 12 of 20

Functional Requirements for Fiscal Metering Systems




reading of the reference is determined, within a defined operating
range and under specified conditions. The defined range can be a
single point or a number of points.

Deviation Value minus the reference value (3.11)
A deviation is the result of a calibration. The deviation can be
determined exactly, in contrast with the error. The deviation is used to
judge the performance of an instrument.

Adjustment Operation of bringing a measuring instrument into a state of
performance suitable for its use (4.30)
An adjustment should minimise the deviation. A single point
adjustment will reduce the deviation to zero, an operating range
adjustment requires a weighing procedure.

Significance Level (SL) Uncertainty in the - conventional - true value
This term is not included in [2], but plays an important role in the
model. The SL value is based on the uncertainty of the applied
reference only.

Maximum Permissible Error (MPE) Extreme values of an error permitted by
specifications, regulations, etc. for a given measuring
instrument (5.21)
The MPE is mutually agreed between parties, either at component or
overall level. Since the error cannot be determined exactly, additional
agreement is necessary on how to deal with such a value.


Assumptions

Every instrument is checked on a regular basis by comparing its reading with a reference.
The uncertainty of the reference is specified.
Any instrument drift within the checking period will remain within specifications.
The calibration procedure does not introduce significant uncertainties.
Either the reference used has no systematic error, or it has a known systematic error
making it possible to compensate.


Single instrument

A single instrument calibration results in a deviation that requires interpretation. It is
supposed that a Maximum Permissible Error value has been agreed upon, and that the
reference uncertainty is specified.
The interpretation of the reference uncertainty is an important aspect of the model. Its origin
lies in the traceability chain leading from the primary reference (say `Paris) to the specific
reference used. The true value is defined by this primary reference, which means that it is by
definition the only reference with zero error. Every next (traceable) step in producing copies
of the reference leads to an additional uncertainty. The result is that the difference between
any (non-primary) reference and the true value is fixed, but unknown. Therefore it is
described by a probability distribution.


GAS TRANSPORT SERVICES
Page 13 of 20

Functional Requirements for Fiscal Metering Systems





The interpretation of the measured deviation is illustrated with the graph below.

1
0
+ MPE
- MPE
Measurement Uncertainty
SL
DEVIATION
SL
Deviations proven within MPE
< 95% Probability
< 50% Probability
Deviations proven within MPE
Adjustment Level
< 50% Probability
Adjustment Level
< 95% Probability
error
ranges


Any deviation is the centre of a probability range of the actual associated error. This implies
that deviations within the MPE boundaries do not automatically represent acceptable errors.
As long as the absolute deviation value is much smaller than the MPE, sufficient certainty is
given that the error also lies within the MPE. With larger deviation values, this certainty
decreases.
At the value MPE - SL, or its opposite, the confidence level of 95% is lost. (Strictly speaking
97.5% for symmetry reasons.) At this stage the guarantee cannot be given anymore that the
instrument operates within the Maximum Permissible Error. It therefore will have to be
adjusted.
This leads to the following relation between the three (absolute) values:

Adjustment Level = MPE - SL

Going further away from the zero level, the certainty decreases further, passing the 50%
value at the MPE level. It must be stressed that, even in this region, it is still possible that
the instrument operates within requirements, but the probability is small.
If both the adjustment and significance levels are known, as is the case in the present
situation at the export delivery points, the MPE values can be calculated for the individual
components.





GAS TRANSPORT SERVICES
Page 14 of 20

Functional Requirements for Fiscal Metering Systems




Multi component significant level

Every measuring system used for fiscal measuring consists of more components, together
determining the energy throughput.
The overall significance level for the energy measurement can be determined from the
individual SL values.

Since these individual values have been deduced from their own original primary reference,
following different intermediate steps, it is assumed that the possible errors (fixed but
unknown) have probability distributions that are not correlated. Therefore, the SL values
should be added quadratically to obtain the overall value.

Furthermore, it is recognised that the deviations in the measured energy are not always
directly proportional to deviations in certain components. This is due to the applied method
of energy calculation.
A typical example is the effect of calorific value deviations when using pTz volume
conversion. The direct influence is through the multiplication of normal volume and calorific
value. The use of calorific value in the sGERG compressibility calculation introduces an
indirect influence as well. It can be estimated that a 1% calorific value deviation will roughly
lead to a 1.25% energy deviation. This influencing factor is somewhat dependent on the
actual operational situation for pressure, temperature and gas quality.
In the same way there are also influencing factors for other quantities. Gas Transport
Services has investigated these for a wide range of operating situations and compressibility
calculation methods. The table below gives the values for the typical situation at the high
pressure delivery stations.


quantity influe
ncing
factor
pressure 1.13
temperature - 1.55
calorific value 1.25
normal density 0.14
CO
2
concentration 0.004

Table 1: Influencing factors for pTz conversion for sGERG and high pressure


In general the overall significance level can be calculated as follows:


SL
2
system
= ( f
1
. SL
comp 1
)
2
+ ( f
2
. SL
comp 2
)
2
+ . . .


where the f values represent the influencing factors.
Mathematically the influencing factors are nothing else than the partial derivatives of energy
with respect to the individual quantities, calculated at the point of operation.



GAS TRANSPORT SERVICES
Page 15 of 20

Functional Requirements for Fiscal Metering Systems





Relation between individual and overall MPE values

Any overall value for the Maximum Permissible Error should be related to the individual MPE-
values.
Above it was stated that individual significance levels are uncorrelated, and may therefore be
added quadratically. The same argument applies to the measured deviations. Therefore the
overall MPE is chosen to have the same relation to the individual MPE values:


MPE
2
system
= ( f
1
. MPE
comp 1
)
2
+ ( f
2
. MPE
comp 2
)
2
+ . . .


From the above an adjustment level for the multi component system can be calculated in the
same way as for the individual components by subtracting the system SL from the system
MPE.


Requirement for overall MPE

An appropriate value for the maximum permissible error will be agreed between parties. The
requirement then reads

MPE
system
<= MPE
required


When the measurement system is engineered, this will be used as a requirement for the
configuration. The instrument specifications, interpreted as MPE-values, are added up as
above and the resulting system value should remain within the requirement.

Once the system is in operation, the results of periodical checks should prove the system to
be within this requirement. For thus purpose the overall deviation should be calculated from
the individual deviations, again making use of the energy calculation method and the
influencing factors. In contrast with the SL and MPE calculation, deviations add up linearly:

DEV
system
= f
1
. DEV
comp 1
+ f
2
. DEV
comp 2
+ . . .

In order to give sufficient guarantee the MPE requirement is not exceeded, the calculated
system deviation be subject to

| DEV
system
| <= MPE
required
- SL
system


where the vertical bars represent the absolute value. The right hand side acts as the system
adjustment level.
If the system deviation exceeds the given limit, some instruments should be adjusted or
replaced.

Remarks:
Due to the quadratic addition of the MPE values it may happen that no individual component
is outside its tolerance, but the system deviation has exceeded the overall adjustment level.


GAS TRANSPORT SERVICES
Page 16 of 20

Functional Requirements for Fiscal Metering Systems




In the numerical example given below such a case is described. It has to be decided then
which instrument should be adjusted. It is advised to adjust the component with the largest
deviation, but left to the personnel on site to decide what is best.

Changes in MPE values can take place when an improvement of a reference can be achieved.
A smaller SL value will reduce the MPE for this particular instrument, allowing for larger
adjustment levels on other components. In this way investment will reduce maintenance
costs and keep the quality at the same level.
An other case is that performance of a certain instrument is worse than expected. The
adjustment level and thus the MPE should be enlarged, but not without tightening the
tolerance on other components.


GAS TRANSPORT SERVICES
Page 17 of 20

Functional Requirements for Fiscal Metering Systems




Numerical example
For the large delivery stations at the Dutch borders, the table below shows the significance
and adjustment levels that have been agreed upon. In the rightmost column the MPE values
have been added. The system SL values on energy and on energy without the primary
measurement are calculated, making use of the influencing factors.
The MPE values for these two quantities are proposed values. It can be calculated that the
system values remain within this requirement, with respective values 0.73% and 0.61%. The
two system adjustment levels are based on MPE
required
and SL values.

The `energy without base volume is important for the monthly overall check, at which all
instruments are calibrated against their reference, except the turbine/US meter. For this
case the `overall value on energy should be the one where the primary measurement is
excluded.

Measured value
or method
Significan
ce
Level
Adjustme
nt
Level
Maximum
Permissible
Error

Base flow

0.3%

0.0 %
(*)

0.4%

Pressure


0.1%

0.15%

0.25%

Temperature


0.03%
(0.1K)

0.07%
(0.2K)

0.10% (0.3K)

Z/Zn method


0.1 %

-

0.1%

Calorific value (GC)


0.2%

0.2%

0.4%

Normal density (GC)


0.2%

0.2%

0.4%

Energy


0.50%

0.25 %

0.75%

Energy without base
volume


0.30%

0.35 %

0.65%

(*) Turbine meters are always adjusted. Any remaining error is removed by the application
of curve correction.




GAS TRANSPORT SERVICES
Page 18 of 20

Functional Requirements for Fiscal Metering Systems




References Uncertainty Modelling
[1] EN 1776
[2] `International Vocabulary of Basic and General Terms in Metrology, ISBN 92-97-
01075-1, International Organization for Standardization, 1993
[3] ISO 6974 Natural Gas - Determination of composition with defined uncertainty by
gas chromatography-" 2000-Part 1: Guidelines for tailored analysis ; 2001-Part 2:
Measuring system characteristics and statistics for data treatment.
[4] ISO/DIS 17089 deel 1: Measurement of flow in closed conduits - Ultrasonic meters
for gas; meters for custody transfer and allocation measurement
[5] ISO-6976, second edition of 1995 "Natural gas - Calculation of calorific value,
density, relative density and Wobbe index from composition."




GAS TRANSPORT SERVICES
Page 19 of 20

Functional Requirements for Fiscal Metering Systems




APPENDIX 2: Long Term Effects, "CUSUM

Several methods are described to detect long term effects. One of these methods is the cumulative
sum method (CUSUM) (Ref 1,2,3). Gas Transport Services has adopted this method.
This method accumulates the realised deviations between measuring instrument and reference
instrument. The long term effect is shown by a growing CUSUM value. By using an alarm limit this
effect can be stopped. A threshold value is introduced to reduce the influence of random deviations.
Both parameters (threshold and alarm limit) can be calculated as a function of the standard deviation
of the control results

Threshold value:
The threshold value is the lower limit for the absolute value of the deviations which are added in the
cumulative sum. A high value makes the system impassive for real problems; a low value gives to
much fake alarms.
In the literature is often chosen for a value of to times the standard deviation.
Action limit:
This is the value where above the absolute value of the cumulative sum gives an alarm. The time
needed to detect the long term effect is called `average run length (ARL). This value is dependent of
the frequency of the calibration and the time in which a systematic error may exist. In case of
monthly calibrations and an action limit of 5 times the standard deviation is chosen, an error of 1
standard deviation will give an alarm after 10 months.

Two CUSUM quantities will be determined for all measurements of calorific value, line density and
normal density called S
+
(..) and S
-
(..).
S
+
is the cusum quantity for the detection of persistent deviations with a positive sign.
S
-
is the cusum quantity for the detection of persistent deviations with a negative sign.

All CUSUM quantities will be updated every calibration with the latest determined deviations.







where:
S
+
t
is the S
+
cusum quantity at period "t
S
-
t
is the S
-
cusum quantity at period "t
S
-
t-1
is S
-
t
in the period before

t
= the relative deviation of the instrument in period "t, either with a positive sign or with negative
sign.
k= threshold value;

When S
+
or S
-
exceed the limit the instrument will be recalibrated
After recalibration or replacement of the instrument its S
+
and S
-
values will be set to 0.

S S k
t t t
+

+
= + max( , ( )) 0
1

S S k
t t t

= + max( , ( )) 0
1



GAS TRANSPORT SERVICES
Page 20 of 20

Functional Requirements for Fiscal Metering Systems





REFERENCES of Long term effects, Cusum
1. ISO 7871 `Introduction to cumulative sum charts
2. `Statistical methods for quality improvement by Thomas P. Ryan , John Wiley & Sons, 1989,
ISBN 0-471-84337-7
3. `Statistical process control by G. Barrie Wetherill and Don W. Brown, Chapman and Hill,
1991, ISBN 0-412-35700-3