PERENNITY DICOM v4.

00 New Features & Improvements

Copyright Perennity sprl-bvba 2004-2011

General Overview

Simplified installation/upgrade procedure

Improved support for Windows 7 & 64-bit platforms

Flexible activity reporting Storage management Data replication Transfer of studies/series to remote AETs Editing of DICOM tags Custom menu Diagnostic reports in PDF Perennity Dicom Server available as an Applet Auto-warming up of Everest printer Worklist filtered on AET Additional languages Improved DICOM Server user interface Improved log display

Copyright Perennity sprl-bvba 2004-2011

Simplified Installation Disc

New simplified Next-Next-Next wizard


Complete installation performed in less than 5 minutes Important required parameters (e.g. storage path) are entered during the installation Automatic configuration of the CD robot (e.g. automatically detects type of printer)

The installation package now includes and installs all required components

JAVA Virtual Machine (JVM)


Perennity requires JVM v6 update 23 or higher If JAVA is already installed the version is check prior to install Perennity

MySQL Database engine Apache Tomcat Web Server Perennity DICOM Sender with one study for test purpose Includes the SDK/APIs toolkit if required (e.g. Epson & Primera robots)

Improved support for Windows 7

All settings are now stored in Documents and Settings folder

Requirement for Windows 7 security

IQ-Lite 2.7 fully supports Windows 7


3

Copyright Perennity sprl-bvba 2004-2011

Simplified Installation Disc

8 different installation CD packages

One installation package per robot vendor


Rimage Epson

Includes the installation of TD-Bridge Checks the version of Epson software

Primera

Includes the Primera SDK Checks the version of Primera software

Perennity DICOM Level 1B


Perennity DICOM Server only No supporting robots

32bit and 64bit packages


Installs the right JAVA Virtual Machine (JVM) Installs the right Apache Web Server
4

Copyright Perennity sprl-bvba 2004-2011

Simplified Installation

Straightforward installation wizard

Copyright Perennity sprl-bvba 2004-2011

Configuration Files
Now located in Document & Settings Required for Windows 7 compatibility

Copyright Perennity sprl-bvba 2004-2011

Reporting

New tool for a Leasing Solution Print or export (PDF, XLS, ) activity reports

List of Patient CDs per day Statistics

Reports can easily be customized

Using user friendly free iReport report design tool

Add you own reports


Create any kind of report using iReport Include parameters (e.g. date range) without writing a line of code

All reports, standard and customized, are available from the Report menu

In the Perennity Dicom Burner Using the Perennity Dicom Burner Applet in a web browser
7

Copyright Perennity sprl-bvba 2004-2011

Reporting

Copyright Perennity sprl-bvba 2004-2011

Storage Management

Pre- PACS Ready Data replication


All DICOM studies sent to Perennity are stored locally A copy can automatically be made to secondary storage

NAS (Network Attached Storage) Silent Cube for long term archiving External cost-effective HDD Network share on a server All we need is a UNC path !

Study deletion is performed by the Dicom Server


You may still decide how many days you want to keep the images Expired images were formerly deleted by the Dicom Burner Makes more sense to delegate deletion process to the Dicom Server

Perennity Level 1B (archive only) does not have the Dicom Burner

History is always kept in the database

Used to be an option

Copyright Perennity sprl-bvba 2004-2011

Data Replication

Copyright Perennity sprl-bvba 2004-2011

10

Transfer Studies to Remote AETs


New button in the Dicom Burner interface Examples

Transfer studies to a Diagnostic Workstation Transfer studies to a central PACS

Copyright Perennity sprl-bvba 2004-2011

11

Editing DICOM Tags


Edit Studies information (e.g. patient name, ID, ) All changes are accurately logged

e.g. Study123: patient name was Smith changed to Johnson Must be activated in the configuration file of the Dicom Burner

Option is disabled by default

Copyright Perennity sprl-bvba 2004-2011

12

Custom Startup Menu on Patient CD


Automatically launched by the autorun Provide the list of the studies contained on the disc Direct link to PDF report Preview of images (JPEG)

Fast access for reviewing the studies

Enable the autorun which is disabled by default in Windows 7

Copyright Perennity sprl-bvba 2004-2011

13

Custom Startup Menu on Patient CD

Very easy to customize

Change the background The size of the image defines the size of the menu window Customize up to three buttons Text Icon Application (e.g. html page, executable, PDF, ) Position & size Position the list of the study anywhere in the window

Simply edit an .ini file

Copyright Perennity sprl-bvba 2004-2011

14

Diagnostic Reports in PDF

Retrieved reports from a RIS/PACS or/and DICOM Structured Report sent to Perennity are now converted to PDF and added to the Patient CDs PDF report is accessible using our custom menu

Copyright Perennity sprl-bvba 2004-2011

15

Perennity Dicom Server Applet

Access the DICOM Server user interface using any web browser

Remote monitoring and configuration of the DICOM Server

Copyright Perennity sprl-bvba 2004-2011

16

Auto Warm-up of Everest

Everest printers are put to sleep after 45 minutes


Save power and improve longevity Warming up process can take up to 5 minutes

Perennity wakes up the printer when receiving a new study


Dramatically improves performance Everest is warming up while images are pre-processed Reduced waiting time for the CD printing any longer Definitely efficient when performing long examinations

e.g. MRI

Copyright Perennity sprl-bvba 2004-2011

17

Improved Support of Worklists

Generate Patient CD on request using the RIS

Perennity is listening to the Worklist of a RIS Filter inputs based on DICOM Burner AET(s) Perennity processes studies that have been added to the Worklist

Retrieve the images belonging to the study Create a Patient disc

Feedback to the RIS once the Patient CD has been produced (MPPS)

Copyright Perennity sprl-bvba 2004-2011

18

Languages

New languages

German

Updates

Brazilian Portuguese Chinese Russian

Language can now be defined when using the Dicom Burner Applet in a web browser

Copyright Perennity sprl-bvba 2004-2011

19

Improved Dicom Server GUI


Password protected New System tab

Shows IP settings

Detailed explanation for each tab

Copyright Perennity sprl-bvba 2004-2011

20

Improve Logs Display


Always displays the last 100 events Does not empty the log window at each restart of the DICOM Burner and Server

Copyright Perennity sprl-bvba 2004-2011

21

Licensing and Downloading

Trial mode

The 2 hours trial mode has been removed You can only send 25 images without a valid activation key (unlimited or demo)

Download of Perennity DICOM has been removed from our web site

We need to know who is downloading what Avoid end-users to upgrade themselves Download links can be requested by email

license@perennitysoft.com

A form will be available soon on our web site

Copyright Perennity sprl-bvba 2004-2011

22

Contact Information

Copyright Perennity sprl-bvba 2004-2011

23