Beruflich Dokumente
Kultur Dokumente
S
Brief description Quantity
r.N Observation
of equipment required Rate quoted per Rate quoted per
o.
number / set as Cost as per our number / set as Cost as per our
applicable requirement applicable requirement
[Rs.Ps.] [Rs.Ps.]
CIVIL
Los Angeles
Abrasion testing
machine
Sieve
2 Shaker[Gyratory for 1 12500.00 12500.00 12500.00 12500.00
200 mm seives]
Compression Testing
machine, electrcally
operated 200 T
The testing machine
quoted by M/s Imperial
3 1 1.00 120000.00 52000.00 52000.00 Lab Equipments , New
Delhi is of capacity to test
upto 100 T
Concrete hammer is
supplied with calibration
Concrete test
27 2 40000.00 80000.00 60000.00 120000.00 chart .
Rebound hammer Cocrete hammer impact
Energy 2.207 Joule
Analytical weight
box with calibration
cetrtificate having
stainless steel M/s Imperial Lab
weights Equipments , New Delhi
31 3 7000.00 21000.00 Not qouted has not quoted .
500 mg, 200 mg,
100 mg, 50 mg,
20 mg , 10 mg, 5 mg,
2 mg, 1 mg, 50 gm ,
100 gm and 200 gm
Mechanical
Elcometer [Coating
thickness Gauge]
[Digital]-Magnetic /
1 conducive base 2 24500.00 49000.00 Not qouted
model including test
and calibration
certificates
Ultrasonic digital
thickness gauge,
hand held Power supply shall be 1.5
microprocessor V - AA Alkaline cells with
battery life upto 250
2 based,display 4 digit 2 38500.00 77000.00 Not qouted Hours.
LCD,measuring The appartus shall be
range 1.00 mm to portable.
225.00.mm, least
count +/- 0.1 mm.
Vernier caliper, 0
-150 mm with LCD Least count shall be 0.01
4 3 2700.00 8100.00 6000.00 18000.00
Readout with mm
calibration certificate
Vernier caliper, 0
-600 mm, four way Least count shall be 0.02
5 3 3400.00 10200.00 Not qouted
fine adjustment with mm
calibration certificate
Outside micrometer ,
Range shall be upto 25
6 0 – 25 mm, 3 1560.00 4680.00 Not qouted mm
Mitutoyo make
Outside micrometer ,
Range shall be upto 100
7 25 – 100 mm, 3 12500.00 37500.00 Not qouted mm
Mitutoyo make
Outside micrometer ,
Range shall be upto
8 100 – 250 mm, 3 22185.00 66555.00 Not qouted 250mm
Mitutoyo make
Inside micrometer ,
Rate is quoted for 25 - 30
9 0 – 50 mm, 3 11250.00 33750.00 Not qouted mm
Mitutoyo make
Portable Hardness
tester,test tip Equipped with data
tungsten proceessor,accurate
10 carbide,least count 1 78000.00 78000.00 Not qouted values can be obtained
+/-0.80 %,maximum even at angles and up-
hardness upto 980 side down
HV
pH meter,
19 3 4500.00 13500.00
digital meter M/s EIE Instruments Pvt
Limited, Ahmedabad
p H meter Range of pH meter shall
microprocessor 3 11500.00 34500.00 be 0 to 14 pH with
based resolution of 0.01 pH
6000.00 54000.00 having accuracy of + / -
pH meter,
0.01/ 0.20 pH
portable pen Make is not specified by
type,microprocessor 3 4200.00 12600.00 by M/s Imperial Lab
facilty with Equipments , New Delhi
calibration
The apparatus proposed
to be supplied by M/s EIE
Instruments Pvt Limited,
Ahmedabad shall be
Tachometer [Non microprocessor based,
portable and light
20 contact type and 3 4000.00 12000.00 6000.00 18000.00 weight,accuracy shall be
digital] +/- 1 RPM upto 5000 RPM
and +/- 0.05 % for RPM
over 5000 RPM.
Range shall be upto
99999RPM.
The apparatus proposed
TDS Meter [0 – to be supplied by M/s EIE
10000 ppm , portable Instruments Pvt Limited,
pen Ahmedabad shall be
21 3 4200.00 12600.00 6500.00 19500.00 microprocessor based,
type,microprocessor
based with portable and light weight.
Range shall be upto 10 -
calibration facility] 1990 PPM.
Electrical
The apparatus shall be
handheld battery operated
range of 0 to 200 Mv / 2V /
20V / 200 V / 1000V / DC ,
0 to 2/30/200/700 V / AC .
Multimeter
1 3 3200.00 9600.00 Not qouted 0 to 200 uA / 2 uA / 20 uA
[Digital],4.5 digit / 200 uA / 10 A AC , 0 to
200 / 2 K / 20 K / 200 K /
2 M / 20 M / Ohm, 0 to
2000 pF / 20 n F / 2 u F /
20 u F / ,0 to 20 KHz .
Insulation tester
Meggar [Motorized]
Range shall be 0 to 20000
0 / 1 / 2,5/ 5 Kv,
2 4 6000.00 24000.00 Not qouted mega ohms,resolution
4 voltages__ shall be 10 megaohms
500 / 1000 / 2000 /
2500 V
Hygrometer with
7 4 2000.00 8000.00 Not qouted Range shall be 0 to 100 %
calibration
Variac [single
phase ],output 0 - Rate is not quoted by M/s
10 270 voltsAC for 4 5500.00 22000.00 Not qouted Imperial Lab Equipments ,
input of 240 volts,20 New Delhi
amp
Tongtester Range 0
-200/1000 amp AC,
0 to 1000 V DC, 0 Rate is not quoted by M/s
11 to 750 V AC , 0 to 4 2100.00 8400.00 Not qouted Imperial Lab Equipments ,
New Delhi
200 ohms/ 20 k
ohms.
Pitch micro Om
Rate is not quoted by M/s
Meter , 0 – 125 mm
14 4 30000.00 120000.00 Not qouted Imperial Lab Equipments ,
range, Mitutoyo New Delhi
make
Temperature
measurement Rate is not quoted by M/s
16 gun[Digital],infrared 2 5400.00 10800.00 Not qouted Imperial Lab Equipments ,
thermometer,laser New Delhi
sighting
17 Motor checker 3 Not Qouted 0.00
pments for FQA Laboratory Comparitve statement detailing the suitablity of testing equ
Determination of thicknesses
of metallic and non- metallic The FQA requirement shall
Proposed to be
materials and for precise be fulfilled with apparatus
purchased from M/s
measurements on various proposed to be supplied by
EIE Instruments Pvt
types of raw M/s EIE Instruments Pvt
Limited, Ahmedabad
materials,component parts and Limited, Ahmedabad
assembled machinery.
have been called from both the suppliers,M/s EIE Instruments Pvt Limited, Ahmedabad and M/s
Imperial Lab Equipments , New Delhi
Determination of hardness of
all metalsInsitu testing of large
The FQA requirement shall
or/and heavy Proposed to be
be fulfilled with apparatus
components,items installed as purchased from M/s
proposed to be supplied by
parts of machine,in the stores EIE Instruments Pvt
M/s EIE Instruments Pvt
for material identification and Limited, Ahmedabad
Limited, Ahmedabad
in locations with difficult
access or in confined spaces.
have been called from both the suppliers,M/s EIE Instruments Pvt Limited, Ahmedabad and M/s
Imperial Lab Equipments , New Delhi