Sie sind auf Seite 1von 10

1.

GENERAL SITE INFORMATION


Site Name/ ID(need photo) Site Address Longitude Access to the Site

HIAL AL KAFOF VSAT-GSM

Survey Date Region

04/072012 SHARKIYA 22.99.58.6N L*W*H

58.88.14.7E

Site Type (Multi-choice) (need photo)

Macro / IBS site

Special Permits Required Allow Work in the Night or not Other Information:

Small truck 4x4 Car Truck - 3,5 t Greenfield Greenfield (Other Partner )Remark: Rooftop Rooftop(Other Partner) Remark: Others Macro IBS: BS80 -SIMENNS Yes No
Remarks:

Latitude Dimension of Equipment Room

Indoor Others Outdoor Semi-Indoor

Allowed

Not Allowed

WORK ONLY DAY TIME

2. EXISTING ANTENNA INFORMATION


Tower Type

Self Support Tower Guyed Mast GI Pole Monopole Tower Camouflage tower Others
Sector A 9 M 9 M 900M Sector B Sector C M M M M Sector D M M Sector A M M

Tower height

6M

Radio Antenna (Need Photo) Feeder Routing Antenna height(Ground level) Antenna Azimuth QTY of antenna of each sector Condition of Existing Structure

1800M Sector B Sector C M M M M

Sector D M M

OMNI 2

Good

OK

Height of Existing Structure

Bad
Other Information:

N/A

3. EXISTING EQUIPMENT ROOM/ODU PAD INFORMATION


Equipment Room(need photo) Equipment Room Size The transmission for BTS : Connecter Type(need photo)

shelter Brick room Outdoor Others


L*W*H
Outdoor PAD Size

WALL MOUNT L*W*H

2M
BNC

E1

Ethernet port

VSAT

Others,_________

Space for new BTS cabinet(If required)

Cable tray information

Feeder window information(need photo)

New BTS3900L New BTS3900 Stack New BTS3900E Cold Swap(No space) Board Expansion Others Height: mm Wide: mm Free space description: QTY of free hole : big size___X_____ Small size___X____ AC Power Type 380V 220V Generator : ___ KVA SCOKET :_____ Input Breaker :__100____ A __220____V ACDB Information Spare Circuit Breaker QTY:
______ ,description_________________ (for example16 A 1P, 2x10A 1P, 6A 1P )

Power System information(need photo)

New Breaker required___X___P


Total rectifiers module (Emerson) Module QTY __X___ Spare Breaker( Ampere and Quantity ): Space for new rectifier Yes No availabe( Non Emerson) QTY____N0 Holes can be used_NO BUSBAR______ Available/Working________ Not Available__N0______

__X___ A Total Battery Capacity __X____ Ah

Existing Bus bar(need photo) Existing light system in Equipment room Other information :

4. Existing Site TRX, Combiner and Cabinet Type Sector ID TRX TYPE
Sector A Sector B Sector C Sector D

Combiner Type

Cabinet Type

5. Extension

Alarms
N0 NEED
Type of alarm termination Does all alarm terminate on DDF: Ye/No If No, pls specify: Longest Length_________

External Extension Alarms QTY Alarm Termination(need photo)

Length of Alarm Cable

Use longest distance as guide.

8.Feeder connectivity
2G Feeder connector type(DIN male, DIN female, N male, N female) (need photo) Combiner(need photo) Combiner location

7/8 Feeder 5/4Feeder Jumper connector type DIN Male N Male DIN female 1/2Feeder Nfemale Yes, Quantity_______X________ ,Type/Vendor______X_________ No cable ladder _______________ Other__________________
Input side

DIN Male N Male DIN female N female DIN Male N Male DIN female N female

Combiner connection type

Output side

9.Length Of Cables
Cable type Length of jumper from the existing feeder connector to the proposed BTS.* Length of Tx(E1 or FE cable) Cable from the proposed BTS to Transmission. Lenth

6M 10M

Cable type Length of power cable from the Proposed BTS to existing power system. Length of grounding Cable from the proposed BTS to Bus bar

Lenth

7M 3M

Notes : 10.Autocad Desing output(must provide Autocad design)


1.Existing equipment room/ODU layout(include all the equipment location ,cable route and so on) 2.Layout of the proposed equipment location and cable route

ATTACHMENT:
Site Plan Sketch Drawing Topographical map Photoes of Site View of Site

Please scan and attach it ( According the actual situation) Please scan and attach it ( According the actual situation) 1.Site view (include:Top view sketchElevation view sketchExtra sketch etc.2.View of shelter / tower / antenna locations (please point in photos). Access.obstructions.Existing.Power distribution.other relevant features.3.The sample just show what photos required,the QTY and view of the photos are determined on the site and should show the information required clearly.

Site Photographs Sector shooting Photos

N/A

Sec- A- at x

Sec- B- at x

Sec- C- at x

SecD- at x

Site Photographs Antenna installation photos

N/A

N/A

Sector A

Sector A

Sector C

Sector D

Site Photographs Sector TMA photos

N/A

N/A

N/A

N/A

Sector A

Sector B

Sector C

Sector D

Site Photographs Existing Cabinet Overview

N/A

Cabinet Overview 1

Cabinet Overview 2

Site Photographs TRX overview of each cabinet

N/A

N/A

N/A

N/A

Cabinet 1

Cabinet 2

Cabinet 3

Cabinet 4

Site Photographs TOC Combiner overview of each cabinet

N/A

N/A

N/A

N/A

Cabinet 1

Cabinet 2

Cabinet 3

Cabinet 4

Site Photographs View Existing Structure locations

N/A

Existing Sec-A

Existing Sec- B

Existing Sec- C

Site Photographs View Existing Equipment Room

N/A

N/A

N/A

Overview of Equipment Room

Equipment room (Left Wall)

Equipment room (Right Wall)

N/A

N/A

N/A

Equipment room (Back Wall)

Equipment room (Front Wall)

ACDB

N/A

N/A

N/A

Feeder Window - Indoor

Calbe Ladder Indoor

Huawei NODEB Equipment

N/A

N/A

Transmission side connecter type

Exsiting Rectifier

Exsiting Battery Bank

N/A

N/A

N/A

Exsiting Bus bar

Alam termination

Feeder connector type

N/A

N/A

Combiner type

Proposed rectifier loaciton(if need)

Proposed BTS location