Click Apply. Select the NE from the Object Tree in the NE Explore. Choose Configuration > NE Time Synchronization from the Function Tree.
After the synchronization mode and relevant parameters are set, click Apply.
Click New. The system displays the Create IF 1+1 Protection dialog box. Set the parameters of the IF 1+1 protection group. Click OK.
IF 1+1 protection support external switching operation. The external switching priority from the highest to the lowest is clear switching, Lockout switching, forced switching, and manual switching.
Select the NE from the Object Tree in the NE Explore. Choose Configuration > Link Configuration from the Function Tree. Click IF/ODU Configuration. Click an IF board or ODU. Then, the system displays the IF/ODU information of the radio link to which the IF board belongs. Set the corresponding IF information of the radio link. Click Apply. Set the corresponding ODU information of the radio link. Click Apply.
Select the IF board from the Object Tree in the NE Explore. Choose Configuration > IF Interface from the Function Tree. Click the IF Attributes tab. Here can set the working mode, link ID, IF port loopback, 2M bit/s wayside service.
Click the ATPC Attributes tab. Set each parameter for the ATPC attributes. The ATPC Enable status, ATPC Upper Threshold, ATPC Lower Threshold, ATPC Adjustment can be configured here.
Select the ODU from the Object Tree in the NE Explore. Choose Configuration > ODU Interface from the Function Tree. Click the Radio Frequency Attributes tab. Configure the transmit frequency and T/R spacing. Click Apply.
Click the Power Attributes tab. Configure the transmit power of the ODU.
Procedure
Select the NE from the Object Tree in the NE Explore. Choose Configuration > CrossConnection Configuration from the Function Tree. Note: Click Scheme to change the VC-12 timeslot numbering scheme used for
Select the NE from the Object Tree in the NE Explore. Choose Configuration > Order wire from the Function Tree. Click the General tab. Configure the order wire information.
Browse Alarms.
By using the Web LCT, you can browse the current and history alarms, the reporting status of alarms for an NE and boards, and abnormal events.