1. Requirements
Verify that the systems meet the minimum requirements listed below :

1.1 Hardware

Page 2

PT. NEC Indonesia 2009

NEC Confidential

1.2 Software

Page 3

PT. NEC Indonesia 2009

NEC Confidential

2. CID Installation
2.1 Task Flow The CID is installed according to the following procedure : - Start up CID installation program - Operate with CID installation wizard - Enter user information - Choose destination location - Select components - Select program folder - Finish the installation and restart the computer

Page 4

PT. NEC Indonesia 2009

NEC Confidential

2.2 Procedure
2.2.1 Startup Installation Program 1. Turn on the PC and start up the OS. 2. Close all other application programs. 3. Insert the installation disk (CID CD-ROM) into the CD-ROM drive. The installation wizard automatically starts up. Then go to step 6, if the installation wizard does not starts, perform steps 4 and 5. 4. Click the Start button in the lower left of the window to show the menu, and select Run. A dialog box with an entry fields appears.

Page 5

PT. NEC Indonesia 2009

NEC Confidential

5. Enter the path in which the CID setup program exists (see the following example), then click the OK button.

Page 6

PT. NEC Indonesia 2009

NEC Confidential

6. The Setup dialog box shown in below appears, showing that all data required for CID installation is loaded automatically. After preparation is completed, the Welcome dialog box will appear to start the CID installation wizard.

This step is the end of the procedure.

Page 7

PT. NEC Indonesia 2009

NEC Confidential

2.2.2 Operate with CID Installation Wizard


After all the necessary data has been loaded, the CID installation wizard will start with the Welcome dialog box. 1. Click the Next button on the Welcome dialog box to proceed. The User Information dialog box will be displayed.

Page 8

PT. NEC Indonesia 2009

NEC Confidential

2. In the User Information dialog box, enter users name, company name and the product serial number. Then click the Next button to proceed. The Choose Destination Location dialog box will be displayed. The loading program will record your information.

Page 9

PT. NEC Indonesia 2009

NEC Confidential

3. The Choose Destination Location dialog boxbshows the destination folder to which the CID program is to be installed. The default directory is C:/CID.

Page 10

PT. NEC Indonesia 2009

NEC Confidential

To change the default destination, click the Browse button to open the Choose Folder dialog box. Enter a desired destination location, then click the OK button to go back to the Choose Destination Location dialog box.

Confirm the destination location you have chosen, then click the Next button on the Choose Destination Location dialog box. The Select Components dialog box will be displayed.

Page 11

PT. NEC Indonesia 2009

NEC Confidential

4. In the Select Components dialog box (Figure 3-10), select the be installed by clicking the check box on the left of each component tick). After selecting all components to be installed, then click The Select Program Folder dialog box will be displayed.

Page 12

PT. NEC Indonesia 2009

NEC Confidential

5. In the Select Program Folder dialog box, select the program folder in which the shortcut icon of the CID application software should be created and saved. You can select the default folder (named CID) or another existing program folder. It is also possible to prepare a new program folder by entering a new folder name in the Program Folders field. After selecting (clicking) the program folder, click the Next button. The Setup Complete dialog box will be displayed.

Page 13

PT. NEC Indonesia 2009

NEC Confidential

2.2.3 Finish CID Installation and Restart Computer


Installation program goes to general setting after the replication work of installation disk finished. Some information will automatically appear and disappear on the screen, and when all the settings have been completed, the Setup Complete dialogbox will be displayed.

Click the Finish button to complete the CID installation. This step is the end of the procedure.
Page 14
PT. NEC Indonesia 2009 NEC Confidential

3. Setup CID
3.1 Serial Port Connection (f Interface) Procedure : 1. Connect the RJ-45 interface to f port of C-Node. 2. Connect the serial interface to serial port of PC. 3.2 Ethernet Communication (F Interface) Procedure : 1. Connect the RJ-45 interface to F port of C-Node. 2. Connect the other RJ-45 interface to Ethernet port of PC.

Page 15

PT. NEC Indonesia 2009

NEC Confidential

3.3 Startup CID


The steps to start up CID are exactly same with those of other Windows applications. Procedure : 1. Confirm that the physical connection between the CID port and a port on C-Node equipment is made correctly. 2. Turn on the computer, and wait until Windows is ready. 3. Confirm that all other applications are closed. 4. Double-click the startup icon to start the CID. The Startup Setting dialogue box as shown in the Figure appears:

Page 16

PT. NEC Indonesia 2009

NEC Confidential

5. Select the language to be displayed in the CID by clicking a radio button English or Chinese. This step is the end of procedure. Go to the next procedure to set up communications.
Page 17
PT. NEC Indonesia 2009 NEC Confidential

3.4 Setup Communication Port


The information entered by these procedures is saved to the registry, and need not to be entered again unless a change needs to be made. Methods for CID communication setup differ depending on the connections as shown below: Serial port connection: Communication with f interface. Select COM. Ethernet communication: Communication with F interface. Select IP Address.

Page 18

PT. NEC Indonesia 2009

NEC Confidential

3.4.1 Serial Port Connection (f Interface)


Procedure : 1. Start up CID (see the section 4.2 Startup CID), and open the Startup Setting dialog box. 2. Select the language to be displayed. 3. Click the check box Online (leaving a tick) so that the CID communicate with SDH equipment. NOTE: When this check box is not selected, the CID runs on offline. Even if running on offline, the CID can support the most of the functions. Offline operation should be used for the condition of single machine operation. 4. Click the radio box COM. NOTE: When COM is selected, the text field for IP Address becomes disabled. 5. Enter the corresponding serial port ( COM port number ). NOTE: Only 38400 should be set as baud rate.

Page 19

PT. NEC Indonesia 2009

NEC Confidential

6. Confirm the entered values, then click the Ok button. The NE Login dialog box will be displayed. This step is the end of the procedure. Go to the section 5. Login/Logout/Exit to login.
Page 20
PT. NEC Indonesia 2009 NEC Confidential

3.4.2 Ethernet Communication (F Interface)


When the CID manages the C_NODE via the Ethernet communication, the Ethernet port of equipment, namely F interface, can be connected to PC (including notebook-type PC) directly or through LAN. Refer to the section Connect CID to C-Node Equipment for details. Procedure 1. Start up CID (see the section Startup CID), and open the Startup Setting dialog box. 2. Select the language to be displayed. 3. Click the check box Online (leaving a tick) so that the CID communicate with SDH equipment. NOTE: When this check box is not selected, the CID runs on offline. During running on offline, the CID cannot configure and control the equipment.

Page 21

PT. NEC Indonesia 2009

NEC Confidential

4. Click the radio box IP Address. NOTE: When IP Address is selected, the text field for COM becomes disabled. 5. Enter the corresponding IP address to login. NOTE: IP address here mentioned here is for F interface of C-Node, and not for CID.

6. Confirm the entered values, then click the Ok button. The NE Login dialog box will be displayed. This step is the end of the procedure. Go to the section Login/Logout/Exit to login.
Page 22
PT. NEC Indonesia 2009 NEC Confidential

5. Login/Logout/Exit NE 5.1 Login to Local NE and Remote NE


Procedure 1. Confirm that the proper connection between the CID and NE is made. 2. Start up the CID and open the NE Login dialog box by referring to the section Setup CID. 3. In the NE Login dialog box, enter user ID and password. Then click the OK button.

Page 23

PT. NEC Indonesia 2009

NEC Confidential

The default User ID and password are shown below:

4. Confirm the entered user ID and password, then select Local by clicking the radio button for local NE, or select Remote by clicking the radio button for remote NE. NOTE: When clicking Remote button, the loopback function from CID is rejected. 5. Click the OK button to login. During logging in operation, the following window will be displayed. This window will be disappeared after login is finished completely.

Page 24

PT. NEC Indonesia 2009

NEC Confidential

6. After successful login, CID will collect the NE data and enter network manager interface after collecting completely. This step is the end of the procedure.

Page 25

PT. NEC Indonesia 2009

NEC Confidential

5.2 Logout of NE
To logout the NE, perform the following procedure: Procedure 1. Confirm the modifications that user had done should be set or canceled. 2. Close the window under operation. 3. Logout the NE on CID. 4. Remove the cable between the NE and CID.

Page 26

PT. NEC Indonesia 2009

NEC Confidential

5.3 Exit CID


To close the CID application and to terminate communication between CID and the NE, perform the following procedure: 5.3.1 Exit CID After Logged Out Procedure 1. Confirm the modifications that user had done should be set or canceled. 2. Exit CID. 5.3.2 Exit CID Without Logged Out Procedure 1. Confirm the modifications that user had done should be set or canceled. 2. Remove the cable between NE and CID. 3. Exit CID.