SUBSEA TREE DESIGN DATA (Includes Wellhead/Downhole) No.

System Design Requirements - Open & Shutdown the Production - Control & Monitor the Flow (Speed, Pressure, Temperature, Sand, etc) - Provide Interfaces to Flowline - Inject Chemical Fluids into the Well and/or Flowlines 5 Vertical (Conventional) 30 years 10,000 Psi -29C to 136C - 185 MMSCFD for long term - 250 MMSCFD for less than 1-month 50m/sec at 250 MMSCFD - Tree : 2 x MEG - Wellhead : Not required No No - Tree : 4 x Pressure and Temperature; 1 x Delta Pressure across the Choke; 1 x Acoustic Sand Detector; 1 x Erosion Probe - Wellhead : 1set of DHPTG; Dual PT (Pressure-Temperature) Sensors No 1 2 Yes Yes Yes Yes Yes Yes -1000m Comments

Functionality

As minimum functionality.

Number of Subsea Tree Tree Type Design Life Pressure Rating Min/Max Operating Temperatures Maximum Flowrate Maximum Flow Velocity Injection Point / Well Smart Well Function Fiber Optic Requirements

Fixed. Fixed. +1,000 Psi as maximum SITHP. The materials shall be charpy tested to -46C. Fixed. -

Sensors / Well

Fixed.

Multiphase Flowmeter Number of SCSSV / Well Number of SCSSV Control Line / Well Annulus Vent Interfaces to Flowline Tree Connector TH System ROV Interface Control Junction Design Water Depth Other Design Materials Rigidity & Reliability Operation Cycle Operating Forces / Torque Design Loads Valve Actuator

Production tubing configured to enable installation of SCSSV bu wire-line, Fixed. Fixed. For umbilical control hookup, Fixed. -

Carbon Steel (anti-corrosive overlay) Yes Minimized Maximum 50 lb-ft ? Yes

May require intervention plan. -

DBB Valve System U-Value Tree Piping Tree Cap Tree Guide Frames TFL Wye Spool Tree Running Tools Retrievable Choke Sealing System Storage Temperature Range Tree Guide Frame

Yes 0,7 Refer to ISO 13628-4 Required Required Required Required Yes Metal to Metal -10C to 70C Yes

Providing guidance for installation and intervention.

Mechanical Performance Maximum allowable mate/de-mate force Minimum mate/de-mate cycle life Connector Shear Load Resistance Hydrocarbon Seal Configuration Misalignment Engagement Connector InterChangeability Debris

500N (112lbf) 100 mates in turbid sand, salt and water Maximum 6.75 metric tons Seals of dissimilar designs and materials are required for all pressure boundaries/barriers. Metal seals are preferred for all primary seals. Connectors shall be interchangeable (inter-mateable) between mating halves and shall not be matched sets. The wetmate interface shall be designed to be tolerant of debris present in the interface during normal mating operations.

Electrical Performance Maximum Working Voltage Test Voltage Maximum Working Current Maximum Contact Resistance Insulation Resistance

600 VDC 2400 VDC 5.0 Amp 30 ohm with 2.0 A load (excluding test leads) per contact pair. - Qualification = 10 G @1000 VDC (1minute duration) - During FAT = 10 G @500 VDC (1minute duration)