Sie sind auf Seite 1von 8

13 34 19/CEC

BuyLine 9109

CE

I L DI NG

SY

R C H I T E C T U R A L

C O

BU

S T E MS

E S O U R C E

Rigid Frame Structural Systems

Metal Roof Panels

Rigid Frame Multi-Span


(with Interior Column)

Endpost
End Frame
(Bearing)
Girts

Purlin

Metal Wall Panels

Rigid Frame Clear Span


(No Interior Column)
Canopy System
Fascia

Rigid Frame Clear Span 20' to 160'


and wider building width, where column-free
floor area is required

Single-Slope Clear Span 20' to 160'


and wider, where column-free floor area and
single-slope is required

Rigid Frame Multi-Span 50' to 500'


and wider, where interior columns do not
impair function of building

Single-Slope Multi-Span 50' to 500'


where interior columns do not impair function
of building and single-slope is required

Flush Wall Clear Span 20' to 70' where


column-free floor area is required in conjunction
with column contained within the girt space

Tapered Beam Straight Column 15'


to 70' used with short-span column-free
interiors where maximum clearance is required

Flush Wall Multi-Span 50' to 250'


where interior columns do not impair function
of building in conjunction with columns
contained within the girt space

Lean-To 10' to 60' an economical way to


increase width of building

Mezzanines and Multistory structural


systems available

Modular Open Web Multi-Span systems


available with open web rafters

13 34 19/CEC
BuyLine 9109

rli

End Frame
(Bearing)

y
ba
ide
W
s
ard
nd stem
Sta Sy

Long B

ay

Pu

Widebay Structural Systems


Support
Column

Endpost

width - length - height - in 1/16'' increments


Roof slope minimum 1/4:12; must utilize
standing seam roof
Bay sizes 30' - 60' and greater
Conventional steel decking can be equally used
as one of Cecos standing seam roof systems
Standing Seam
Roof Panels

Girts

n
atio
plic stem
p
A
y
all ay S
-W
Tilt ideb
to W

Metal
Wall Panels

Open Web Rafter


Lateral Support Beam
(As Required By Design)

Longbay Joist

Fascia

Precast or Tilt-Up
Concrete Panel

Rigid Frame Multi-Span


(with Tapered Column)

Tilt-Wall Systems

Fascia Systems

Any of Cecos frame types can be used with tilt-wall


construction. Each system is designed to ensure structural
integrity and to meet applicable building code criteria.

Ceco buildings are designed to integrate with a wide


variety of fascia treatments.
Cap Flashing

Metal Flashings
Metal Flashing
Scupper

Panel
Gutter

Metal Roof
Insulation

Liner Panel
Face Panel
Scupper

Purlin
Precast
Concrete Panel
Weld
Plate Precast

Inside Closure
Roof Panel
Gutter

Interior Drain
Sheeting Angle
Beam Support

Base Trim

Building Frame

Trim Flashing

Wall Panel
Soffit Panel
Projection

Soffit Trim

Rigid Frame Clear Span


CLEARANCE DIMENSIONS (FEET-INCHES)
CL SYMN.

12
1

E.H.

C*
B

/2 SPAN

*C = Minimum clearance other than at knee (dimension


B). All points where rafter changes shape are checked
and vertical dimension to lowest of these points is given.

REPRESENTATIVE
CLEARANCE DIMENSIONS
1:12 ROOF SLOPE
ROOF SLOPE - 1:12
BAY SPACING - 25 FT
WIND LOAD APPLIED IN
ACCORDANCE WITH ASCE 7-02,
EXPOSURE B

FRAME
20/90
SIZE
A
B
SPAN E.H.
26-11
8-5
10
26-11 12-5
30 14
26-11 14-5
16
26-11 18-5
20
10
36-5
8-2
36-7 12-2
40 14
16
36-7 14-2
20
36-7 18-2
12
45-3 9-11
45-5 13-11
50 16
20
45-5 17-11
24
45-7 21-9
12
53-11
9-2
53-5 13-3
60 16
20
53-5 17-3
24
53-5 21-3
12
72-9
8-6
71-9 12-6
80 16
20
71-9 16-4
24
71-7 20-4
16
91-5 12-0
91-5 16-0
100 20
24
91-5 20-0
30
91-5 26-0
16
111-1 11-8
20
110-11
15-7
120
24
110-5 19-7
30
109-9 25-9

C
9-6
13-6
15-6
19-6
9-8
13-8
15-8
19-8
11-10
15-10
19-10
23-8
11-4
15-6
19-6
23-6
11-7
15-8
19-9
23-9
15-9
19-9
23-9
29-8
15-3
19-1
23-1
29-7

A
26-11
26-11
26-11
26-11
36-5
36-7
36-6
36-6
45-3
45-5
45-1
45-7
53-11
53-5
53-5
53-5
72-9
71-9
71-9
71-7
91-5
91-5
91-5
91-5
111-1
110-11
110-5
109-11

LIVE LOAD / WIND LOAD


20/100
25/90
B
C
A
B
8-5
9-6
26-11
8-5
12-5
13-6
26-11 12-5
14-5
15-6
26-11 14-5
18-5
19-6
26-11 18-5
8-2
9-8
35-11
8-2
12-2
13-8
36-0 12-2
14-2
15-8
36-0 14-2
18-2
19-8
36-0 18-2
9-11 11-10
44-9
9-9
13-11 15-10
44-11 13-11
17-11 19-10
44-5 17-10
21-9
23-8
44-11 21-9
9-2
14-4
53-9 8-11
13-3
15-6
52-11 13-0
17-3
19-6
53-5 17-2
21-3
23-6
53-3 21-2
8-6
11-7
72-7
8-3
12-6
16-8
71-7 12-4
16-4
19-9
71-5 16-5
20-4
23-9
71-5 20-5
12-0
15-9
91-5 12-0
16-0
19-9
91-5 16-0
20-0
23-9
91-1 20-0
26-0
29-8
91-1 26-0
11-8
15-3
110-5 11-1
15-7
19-1
109-7 14-11
19-8
23-1
108-9 19-0
25-9
29-7
108-5 24-11

C
9-6
13-6
15-6
19-6
9-8
13-8
15-8
19-8
11-8
15-10
19-8
23-8
11-5
15-6
19-6
23-6
11-8
15-8
19-10
23-10
15-6
19-8
23-7
29-6
15-1
19-6
23-7
29-6

A
26-11
26-11
26-11
26-10
35-7
35-5
35-7
35-9
44-3
43-11
43-7
44-3
53-7
52-5
52-5
52-5
71-11
71-5
71-5
71-5
91-1
90-1
89-11
89-7
110-3
109-7
108-5
108-5

30/90
B
8-5
12-2
14-2
18-1
7-11
11-11
13-11
17-11
9-10
13-10
17-10
21-7
9-0
13-0
17-0
21-0
8-3
12-2
16-1
20-3
11-7
15-8
19-8
25-8
10-9
14-10
18-11
24-11

C
9-6
13-3
15-3
19-3
9-5
13-5
15-5
19-5
11-8
15-8
19-8
23-5
11-5
15-6
19-6
22-6
11-9
15-8
19-8
23-9
15-9
19-10
23-10
29-10
15-1
19-5
23-6
29-6

Notes: 1. Clearances shown are approximate. Actual Clearances may be somewhat


different.
2. Live loads greater than 30 lbs. must be quoted. Please contact the
estimating department at your regional office.
3. Clearances are based on the use of 8.5 in Girts and Purlins.

Rigid Frame Multi-Span

C LEA RA N CE D IMEN SIO N S (FEET-IN C H ES)


LIVE LOAD/WIND LOAD

Frame
Size
CL SYMN.

12

E.H.

C*
A

SPAN

SPAN
1

/2 BAND WIDTH

*C = Minimum clearance other than at knee (dimension


B). All points where rafter change shapes are checked
and vertical dimension to lowest of these points is given.

REPRESENTATIVE
CLEARANCE DIMENSIONS
1:12 ROOF SLOPE
BAY SPACING

25 ft.
ROOF SLOPE

1:12
Wind Load Applied in accordance with
ASCE 7-02, Exposure B

SPAN E.H.
10
2
14
at
40 16
20
10
2
14
at
60 16
20
12
3
16
at
40 20
24
12
3
16
at
60 20
24
12
4
16
at
40 20
24
16
4
20
at
60 24
30
16
5
20
at
60 24
30

A
76-11
76-11
76-11
76-11
112-0
112-4
112-6
113-5
116-11
116-11
116-11
116-6
173-7
173-5
173-5
173-5
156-11
156-11
156-11
156-5
233-5
233-7
233-5
233-5
293-5
293-5
293-5
293-5

20/90
B
7-11
11-9
13-9
17-9
6-6
11-1
13-1
17-6
9-11
13-11
17-11
21-11
9-0
13-2
17-3
21-4
19-11
13-11
17-11
21-11
13-3
17-4
21-5
27-7
13-3
17-5
21-5
27-6

C
11-1
14-11
16-11
20-11
11-7
15-6
17-5
21-4
14-9
18-9
22-9
26-9
14-1
18-0
21-11
25-10
16-5
20-5
24-5
28-5
17-10
21-9
25-9
31-8
17-10
21-9
25-9
31-8

A
76-11
76-11
76-11
76-11
112-0
112-4
114-3
113-5
116-11
116-11
116-11
116-7
173-7
173-7
173-5
173-5
156-11
156-11
156-11
156-5
233-5
233-5
233-5
233-3
293-5
293-5
293-5
293-5

20/100
B
7-11
11-9
13-9
17-9
6-6
11-1
13-4
17-6
9-11
13-11
17-11
21-11
9-0
13-1
17-0
21-4
9-11
13-11
17-11
21-11
13-3
17-5
21-5
27-7
13-4
17-5
21-5
27-5

C
11-1
14-11
16-11
20-11
11-7
15-8
17-5
21-4
14-9
18-9
22-9
26-9
14-1
18-0
21-11
25-10
16-5
20-5
24-5
28-5
17-10
21-9
25-9
31-8
17-10
21-9
25-9
31-8

A
76-8
76-11
76-11
76-11
112-2
113-5
113-5
113-5
116-6
116-8
116-11
116-6
173-3
172-7
172-7
173-5
156-8
156-11
156-11
156-7
232-11
233-5
233-5
233-3
292-11
293-5
293-5
293-5

25/90
B
7-6
11-6
13-6
17-6
6-11
11-3
13-1
17-2
9-9
13-9
17-9
21-9
8-9
12-9
17-0
21-4
9-9
13-9
17-9
21-9
13-2
17-4
21-5
27-7
13-2
17-3
21-4
27-8

C
10-8
14-8
16-8
20-8
11-2
15-0
16-11
20-10
14-7
18-7
22-7
26-7
13-10
17-9
21-8
25-7
16-3
20-3
24-3
28-3
17-7
21-5
25-5
31-4
17-6
21-5
25-5
31-5

A
76-2
76-8
76-8
76-11
113-0
112-11
112-5
112-7
116-1
116-6
116-8
116-5
172-11
172-1
172-3
172-3
156-6
156-8
156-11
156-6
232-3
232-5
232-9
232-3
292-5
292-5
292-5
292-5

30/90
B
7-6
11-5
13-5
17-4
6-9
11-0
13-1
17-1
9-9
13-6
17-6
21-6
8-6
12-8
16-9
20-10
9-6
13-6
17-6
21-6
12-10
16-11
21-3
27-1
12-10
16-11
21-0
27-1

Notes: 1. Clearances shown are approximate. Actual clearances may be somewhat


different.
2. Live loads greater than 30 lbs. must be quoted. Please contact the
estimating department at your regional office.
3. Clearances are based on the use of 8.5 in Girts and Purlins.

C
10-8
14-7
16-7
20-7
10-8
14-9
16-9
20-8
14-7
18-4
22-4
26-4
13-7
17-5
21-4
25-3
16-0
20-0
24-0
28-0
17-3
21-3
25-1
31-2
17-1 1
21-1 1
25-1 1
31-1 1

13 34 19/CEC
BuyLine 9109

Single Slope Clear Span


C LEA RA N CE D IMEN SIO N S (FEET-IN C H ES)
12

E.H.

C*

SPAN

*C = Minimum clearance other than at low side knee


(dimension B). All points where rafter changes shape are
checked and vertical dimension to lowest of these points
is given. If entire rafter has parallel flanges C is the vertical
clearance at the high side knee.

REPRESENTATIVE
CLEARANCE DIMENSIONS
1:12 ROOF SLOPE
BAY SPACING

25 ft.
ROOF SLOPE

1:12
WIND LOAD APPLIED IN
ACCORDANCE WITH ASCE 7-02,
EXPOSURE B

Single Slope Multi-Span


12

E.H.

C*

SPAN

SPAN
BLDG. WIDTH

*C = Minimum clearance other than at knee


(dimension B). All points where rafter changes shape are
checked and vertical dimension to lowest of these points
is given.

CLEARANCE DIMENSIONS
1:12 ROOF SLOPE
BAY SPACING

25 ft.
ROOF SLOPE

1:12
WIND LOAD APPLIED IN
ACCORDANCE WITH ASCE 7-02,
EXPOSURE B

FRAME
SIZE
SPAN E.H.
10
20 12
14
16
10
30 12
14
16
10
40 12
14
16
12
50 14
16
18
12
60 14
16
20
12
80 14
16
20
12
100 14
16
20

LIVE LOAD / WIND LOAD


A
16-11
16-11
16-11
16-11
26-11
26-11
26-11
26-11
36-6
36-6
36-6
36-6
45-6
45-6
45-6
45-6
53-8
53-8
53-8
53-8
72-4
72-2
72-0
71-10
91-9
91-7
91-5
91-3

20/90
B
8-5
10-5
12-5
14-5
8-5
10-5
12-5
14-5
8-2
10-2
12-2
14-2
9-11
11-11
13-11
15-11
9-4
11-4
13-4
17-4
8-8
10-8
12-8
16-8
8-5
10-5
12-5
16-5

C
9-10
11-10
13-10
15-10
10-8
12-8
14-8
16-8
11-2
13-2
15-2
17-2
13-9
15-9
17-9
19-9
11-5
13-5
15-5
19-5
11-4
13-4
15-4
19-4
10-8
12-8
14-8
18-8

A
16-11
16-11
16-11
16-11
26-11
26-11
26-11
26-11
36-6
36-6
36-6
36-6
45-6
45-6
45-6
45-6
53-8
53-8
53-8
53-8
72-4
72-2
72-0
71-10
91-9
91-7
91-5
91-3

20/100
B
8-5
10-5
12-5
14-5
8-5
10-5
12-5
14-5
8-2
10-2
12-2
14-2
9-11
11-11
13-11
15-11
9-4
11-4
13-4
17-4
8-8
10-8
12-8
16-8
8-5
10-5
12-5
16-5

C
9-10
11-10
13-10
15-10
10-8
12-8
14-8
16-8
11-2
13-2
15-2
17-2
13-9
15-9
17-9
19-9
11-5
13-5
15-5
19-5
11-4
13-4
15-4
19-4
10-8
12-8
14-8
18-8

25/90
B
8-5
10-5
12-5
14-5
8-5
10-5
12-5
14-5
8-2
10-2
12-2
14-2
9-11
11-11
13-11
15-11
9-3
11-3
13-3
17-3
8-8
10-8
12-8
16-8
8-0
10-0
12-0
16-0

A
16-11
16-11
16-11
16-11
26-11
26-11
26-11
26-11
36-6
36-6
36-6
36-6
45-2
45-2
45-2
45-2
53-0
53-0
53-0
53-0
72-2
72-0
71-10
71-8
90-6
90-6
90-6
90-6

C
9-10
11-10
13-10
15-10
10-8
12-8
14-8
16-8
11-2
13-2
15-2
17-2
13-8
15-8
17-8
19-8
11-4
13-4
15-4
19-4
11-4
13-4
15-4
19-4
10-8
12-8
14-8
18-8

A
16-11
16-11
16-11
16-11
26-11
26-11
26-11
26-11
35-11
35-11
35-11
35-11
44-6
44-6
44-6
44-6
52-8
52-6
52-4
52-2
71-11
71-9
71-7
71-5
90-1
90-1
90-1
90-1

30/90
B
8-5
10-5
12-5
14-5
8-4
10-4
12-4
14-4
8-2
10-2
12-2
13-11
9-9
11-9
13-9
15-9
9-1
11-1
13-1
17-1
8-6
10-6
12-6
14-6
8-0
10-0
12-0
16-0

C
9-10
11-10
13-10
15-10
10-7
12-7
14-7
16-7
11-2
13-2
15-2
16-11
13-6
15-6
17-6
19-6
11-1
13-1
15-1
19-1
11-4
13-4
15-4
19-4
10-2
12-2
14-2
18-2

Notes: 1. Clearances shown are approximate. Actual Clearances may be somewhat different.
2. Live Loads greater than 30 lbs must be quoted. Please contact the estimating
department at your regional office.
3. Clearances are based on the use of 8.5 in Girts and Purlins.

IMEN SIO N S (F(FEET-INCHES)


CCLEARANCE
LEA RA N C E DDIMENSIONS
EET-IN C H ES)
LIVE LOAD / WIND LOAD

FRAME
SIZE
SPAN E.H.
12
2
at 14
40 16
20
12
2
at 14
60 16
20
12
3
at 14
40 16
20
12
3
at 14
60 16
20
12
4
at 14
40 16
20
12
4
at 14
60 16
*** 20
12
5
at 14
40 16
20

A
76-11
76-11
76-7
75-4
114-7
114-7
114-7
114-5
116-11
116-7
116-0
114-11
174-7
174-7
174-7
174-1
156-4
156-0
155-1
154-3
234-8
234-5
234-5
232-5
196-2
195-1
194-8
194-2

20/80
B
9-11
11-11
13-11
17-11
10-2
12-2
14-2
17-9
9-11
11-11
13-11
17-9
10-2
12-2
13-9
17-7
9-11
11-11
13-11
17-10
9-11
11-6
13-6
16-10
9-11
11-11
13-10
17-10

C
13-1
15-1
17-1
21-1
13-7
15-6
17-6
21-6
13-1
15-1
17-1
20-11
13-9
15-6
17-6
21-6
13-1
15-1
17-1
20-11
13-4
15-4
17-4
21-4
13-1
15-1
16-11
20-11

A
76-11
76-11
76-7
75-4
114-7
114-7
114-7
114-3
116-11
116-3
115-11
114-7
174-7
174-5
174-5
173-7
156-0
155-9
154-11
154-1
234-8
234-5
234-3
233-0
196-0
195-1
194-6
193-6

20/100
B
9-11
11-11
13-11
17-11
10-2
12-2
14-2
17-9
9-11
11-11
13-9
17-9
10-2
12-2
13-9
17-4
9-9
11-11
13-11
17-10
9-11
11-6
13-6
16-10
9-11
11-11
13-10
17-8

C
13-1
15-1
17-1
21-1
13-7
15-6
17-6
21-6
13-1
15-1
16-11
20-11
13-9
15-4
17-4
21-4
12-11
15-1
17-1
20-11
13-4
15-4
17-4
21-4
13-1
15-1
16-11
20-8

A
76-11
76-11
76-7
75-4
114-2
113-11
113-11
113-11
116-8
116-3
115-11
114-7
173-10
173-5
173-5
172-10
156-0
155-9
154-11
154-1
233-11
233-9
233-2
232-11
196-0
195-1
194-2
193-6

25/90
B
9-9
11-9
13-9
17-9
10-2
12-0
14-0
17-9
9-9
11-9
13-9
17-9
10-2
11-11
13-9
17-4
9-9
11-9
13-6
17-7
9-11
11-6
13-6
16-10
9-9
11-9
13-7
17-7

C
12-11
14-11
16-11
20-11
13-2
15-5
17-2
21-4
12-11
14-11
16-11
20-11
13-3
15-3
17-3
21-3
12-11
14-11
16-8
20-8
13-4
15-4
17-4
21-4
12-11
14-11
16-11
20-8

A
76-9
76-9
76-5
75-2
113-4
113-4
113-4
113-4
116-7
116-3
115-11
114-7
173-3
172-9
172-9
172-6
156-0
155-9
154-11
154-1
233-8
233-3
233-0
232-11
196-0
195-1
194-2
193-6

30/90
B
9-6
11-6
13-6
17-6
10-2
12-0
13-10
17-9
9-9
11-9
13-9
17-9
9-11
11-11
13-9
17-4
9-6
11-6
13-6
17-7
9-11
11-6
13-6
16-10
9-6
11-9
13-7
17-7

C
12-8
14-8
16-8
20-8
13-2
15-5
17-2
21-4
12-11
14-11
16-11
20-11
13-0
15-0
17-0
21-0
12-8
14-8
16-8
20-8
13-4
15-4
17-4
21-4
12-8
14-11
16-8
20-8

*** Roof step should be considered.

Notes: 1. Clearances shown are approximate. Actual Clearances may be somewhat different.
2. Live Loads greater that 30 lbs must be quoted. Please contact the estimating
department at your regional office.
3. Clearances are based on the use of 8.5 in Girts and Purlins.

Note: Ceco buildings are designed to the specific requirements of the project and are flexible in increments of 1/16'' in length, width, height, and column spacing. These
tables are meant to provide typical rigid frame clearance dimensions expected based on conditions shown. Actual clearance may vary based on the unique requirements of
each job and changes in bay spacing, roof slope or loads will affect clearance dimensions.
Buildings with dimensions exceeding the spans and eave heights shown are available by request. Also buildings with roof loads greater than 30 PSF must be quoted.
Tables providing clearance dimensions for Flush Wall, Tapered Beam and Lean-to types can be found in the Ceco Design Manual or on the Web at
www.cecobuildings.com.

Two Ceco Standing Seam Roofs

24

Z purlin or bar joist


(Z purlin shown with
optional thermal block)

CXP (Standing Seam Roof Panel) is roll-formed 24 inches wide. Each


edge corrugation is one half of a major rib and has a standing leg on top of
the half rib that interlocks with the adjacent panel. Edge corrugation is 2 inches
high (2 7/8 inches including the standing leg). All major ribs taper from 1 inch
at top to 4 1/4 inches at base.
Interlocking standing legs at side laps are field seamed together into a 360
Pittsburgh Double Lock Seam by use of an electric seaming tool. Factory
applied sealant is provided in the overlapping standing seam leg to assure
weathertightness of the seamed joint. Concealed clips, which are seamed into
the panel side lap, are furnished by Ceco to fasten panels to structural
members. Panels are factory prenotched for correct makeup at end laps.
Each panel provides 24 inches of coverage. Panel finish is either acrylic coated
GALVALUME or selected Ceco paint colors.
CXP has achieved UL 90 listing, has certification of the American Society for
Testing and Materials (ASTM) E1592 test and has been approved by Factory
Mutual as a Class 1 panel roof.

CXP
Standing Seam Roof Panel

BattenLok HS is a structural roofing panel which can be installed


directly over purlins or bar joists eliminating a solid substructure for
support. BattenLok HS is a mechanically seamed roof system with panels
available in 12 inch and 16 inch widths. Factory applied mastic inside of
female leg of panel is standard. Recommended for roof slopes of 1/2:12
or greater, BattenLok HS has weathertight and aesthetically pleasing
endlaps which may be accomplished through the use of swaged and
prepunched panels. Ceco provides a prepunched back-up plate at the
endlap for weathertightness. Swaged endlaps require the roof erection
to proceed from right to left as viewed from the eave looking toward the
ridge. Roofs with no endlaps and a roof slope less than 6:12 may be
erected from either direction. Heavier gauges, striations, embossing and
installation over solid deck minimize oil canning. Industry standard is a
minimum of 24 gauge material. Striations are standard to reduce oil
canning. Oil canning is not a cause for rejection. Panels are available with
the option of striations with pencil ribs. Substructure must be on an even
plane from eave to ridge to avoid panel distortion (1/4'' in 20', 3/8''
in 40' tolerance.) All panels require end sealant at eave and valley
conditions.
BattenLok HS Striated Panel

BattenLok HS Pencil Rib Panel

13 34 19/CEC
BuyLine 9109

Ribbed Wall Panels & Ribbed Roof Panel


MVW has 1 1/8 inch deep major ribs
which taper in width from 1 3/4 inches
to 3 1/2 inches and are spaced 12
inches on center. Between each major
MVW
rib are two minor stiffening ribs.
The leading edge rib has a bearing leg. Each panel provides 3 feet
of lateral coverage. Panel finish may be specified as GALVALUME or any one
of the Signature panel colors.

MAP has 1 1/2 inch deep major ribs


which taper in width from 2 inches to
3 15/16 inches and are spaced 12
MAP
inches on center. Between each
major rib are two minor stiffening
ribs and two small pencil ribs. The leading edge rib has a bearing
leg. Each panel provides 3 feet of lateral coverage. Panel finish may be
specified as GALVALUME or any one of the Signature panel colors.

This panel is being replaced by MBCI PBR.


Reference: www.mbci.com

CWP16 is roll-formed with the face


of the panel having an inset portion
CWP16
in the center third of the 16-inch
width. Panel is 3 inches deep at
the high planes and 1 1/2 inches deep at the low plane.
Side laps are of interlocking flange design to form a rigid, permanently
tight joint that wont open up or pull apart. Panels are connected to
supporting structural members with fasteners that are concealed from
exterior view.
Entire face of panel is embossed to add texture, and finish is an
extended life color coating (KYNAR) from selected Signature panel colors.

MSP has 1 1/4 inch deep major ribs


which reverse taper in width from 2
3/4 inches to 3/4 inches and are
MSP
spaced 12 inches on center. Between
each major rib, the panel is formed
into a sculptured valley shape with six small pencil ribs in each
valley. Each panel provides 3 feet lateral coverage. Panel finish may
be specified as GALVALUME or any one of the Signature panel colors.
This panel is being replaced by MBCI PBA.
Reference: www.mbci.com

This panel is being replaced by MBCI Shadow Rib.


Reference: www.mbci.com
MIP has 3/4 inch deep ribs which
taper in width from 1 1/8 inches to
2 inches and are spaced 6 inches on
MIP
center. The leading edge rib has a
bearing leg. Each panel provides
3 feet of lateral coverage. Panel finish may be specified as GALVALUME
or any one of the Signature panel colors.

Ribbed Roof Panel


MAP has 1 1/2 inch deep major ribs
which taper in width from 2 inches to
3 15/16 inches and are spaced 12
MAP
inches on center. Between each major
rib are two minor stiffening ribs and two small pencil ribs. The leading
edge rib has a bearing leg. Each panel provides 3 feet of lateral coverage. Panel finish my be specified as GALVALUME or any one of Cecos
Signature panel colors. Note: MAP has achieved UL 90 listing.

This panel is being replaced by MBCI PBU.


Reference: www.mbci.com

3/4''

1'-4'' COVERAGE

CECOROC is an interlocking side rib,


concealed fastener panel manufactured
from 20 gauge hot-dipped G90 galvaCECOROC
nized steel that is coated on the exterior
side with a specially formulated marble crush textured paint finish. The
panel depth is 3/4 inch and each panel provides 16 inches of lateral coverage and is available in lengths up to 20 feet. Panel (not gutter or rake trim)
trim profiles are available in the same finish as the panel. Refer to color
chart for available colors. Special custom colors are available in minimum
quantities.

GALVALUME is a registered trademark of BIEC International, Inc.

KYNAR is a registered trademark of Elf Atochem


Signature 200 is a registered trademark of MBCI
Signature 300 is a registered trademark of MBCI

Cecos Color Selection Chart featuring Signature 200 silicone polyester


colors and Signature 300 Kynar colors can be accessed on its website:
www.cecobuildings.com

Ceco Building Systems

Ceco meets the following standards

Further Design Assistance

AISC-MB Certification
CAN/CSA A660-04
AWS D1.1 Welding Standard
AWS D1.3 Welding Standard
ASTM E1592 Static Pressure Differential Test
Factory Mutual Class 1
Underwriters Laboratories UL 580 Class 90
Member MBMA
Member SBCCI
State of Florida Product Approval #S FL1723, FL1724, FL1726
Miami-Dade County NOA 04-0122.18 expires 7/29/2009;
NOA 04-0122.19 expires 1/27/2010;
NOA 04-0122.20 expires 7/15/2009

To assist architects, engineers, specifiers and other design professionals, Ceco


has the following support available:

Ceco Home Page www.cecobuildings.com To obtain


additional information and locate your local Ceco Sales
Representative and/or Ceco Builder(s)
Ceco Corporate Office Please contact us at 1-800-474-2326
(phone), 662-327-7309 (fax) or marketing@cecobuildings.net.
We would be pleased to assist you with technical questions and/or
send a Product Manual/CD- ROM with specifications and details.

AISI Specification for the Design of Cold-Formed Steel Structural Members


AISC Specification for Structural Steel Buildings
ASTM A36
ASTM A529
ASTM A1011
ASTM A572
ASTM A653
ASTM A755
ASTM A792
ASTM A307
ASTM A325
ASTM A475
ASTM A500

Contact our closest regional office/plant location


and discuss your project with the VP of Sales:
Eastern Region: Tim Schrock: 252-407-1840
Midwest Region: Lynn Chesnut: 319-385-8001, ext. 210
Southern Region: Mike Round: 662-243-2752

Ceco
Locations

State of Florida
Product Approval

8-09

Ceco Building Systems is an NCI Company, which has 40 manufacturing facilities in 18 states
including Arizona, California, Georgia, Illinois, Indiana, Iowa, Kentucky, Michigan, Mississippi, North
Carolina, Nebraska, New York, Oklahoma, Tennessee, Texas, Utah, Virginia, Washington and
one in Mexico. NCI has a sales office in Canada.

Das könnte Ihnen auch gefallen