1 Introduction....................................................................................................................... 3
2 TFT MANAGER APPLICATION ........................................................................................ 4
2.1 GROUPS ..................................................................................................................... 5
2.1.1 ADD GROUP ....................................................................................................... 6
2.1.2 DESCRIPTION .................................................................................................... 7
2.1.3 DELETE GROUP ................................................................................................. 8
2.2 DEVICES..................................................................................................................... 9
2.3 TIMES ....................................................................................................................... 11
2.3.1 GLOBAL DEFINITION ....................................................................................... 12
2.3.2 GROUP TIMES .................................................................................................. 14
2.3.3 DEVICE TIMES .................................................................................................. 15
2.4 LOAD NEW CONFIGURATION ................................................................................ 16
2.5 EMERGENCY ........................................................................................................... 19
2.5.1 - Force immediate switch on for all TFT devices (and disable time rules) ........ 19
2.5.2 - Re-enable time rules ........................................................................................ 19
2.5.3 - Re-start server application (*) .......................................................................... 19
Page 2 of 20
solari udine
1 Introduction
The aim of this document is to provide the guidelines to use the Solari application named
“TFT MANAGER”.
The goal of TFT MANAGER application is to build and manage the time rules necessary to
switch-off and switch-on the lamps of all the TFT devices installed in an I.D.S. (Information
Display System), in order to safeguard the lifetime of each device.
Page 3 of 20
solari udine
The first operation to do for using TFT Manager Application is, obviously, login.
It’s enough to open the browser and point the URL /tftmanager (relative to the lbserver).
Example :
http://lbsrv/tftmanager/
Starting the TFT MANAGER application the main window printed in FIG.1 will be displayed.
At the top of the screen the BUTTON BAR with the following buttons will appear:
- GROUPS
- DEVICES
- TIMES
- LOAD NEW CONFIGURATION
- EMERGENCY
Page 4 of 20
solari udine
2.1 GROUPS
The user has the possibility to create, delete or modify groups, using the GROUP NAME
combo box.
What is a group ?
A group is a logical subdivision for one or more TFT devices with the same switch on-off time
rules. For example in an airport application we can consider all gate TFT devices belonging to
the group GATES, all the check-in TFT devices belonging to the group CHECK-IN etc.
Splitting the TFT devices in different groups can be helpful because the application is
designed to define a single switch on-off time rule that can be automatically assigned to all
TFT devices belonging to the same group (see chapter 2.3.2).
Page 5 of 20
solari udine
Pressing ADD GROUP button the form printed in FIG.3 will be displayed.
To add a new group the fields Group Name and Description must be both meaningful,
otherwise an error message will be displayed.
Press CONFIRM to apply the insertion of the new group or EXIT to abort the operation.
Page 6 of 20
solari udine
2.1.2 DESCRIPTION
Pressing MODIFY DESCRIPTION button the form printed in FIG.4 will be displayed.
Group Name field is protected: the user can only modify the description.
Press CONFIRM to apply the description update or EXIT to abort the operation.
Page 7 of 20
solari udine
Pressing DELETE GROUP button the form printed in FIG.5 will be displayed.
Press CONFIRM to apply the deletion of the selected group or EXIT to abort the
operation.
Page 8 of 20
solari udine
2.2 DEVICES
Getting data (automatically) from the SYSTEM CONFIGURATOR, the complete list of all
system devices (TFTs, LED devices, FLAP devices, etc) will be displayed (columns:
DEVICE and DESCRIPTION).
st
1 STEP
The user must define all TFT devices, checking the column CHECK IF TFT. In this way all
other devices will not be handled by the application.
2nd STEP
The user can create the relationship between TFT and GROUP, using the GROUP combo
box. The fields:
- SWITCH OFF
- SWITCH ON
- WEEKLY FREQUENCY
- ENA / DIS
cannot be modified with this function and could be empty.
Page 9 of 20
solari udine
Press SAVE to apply all the updates or EXIT to abort the operation.
P.S. If ENA / DIS flag is 0 the switch on-off time rules are not handled !!!
If in the peripheral system configuration the number of TFT devices is greater than the
number of other devices the button CHECK ALL AS TFT can be helpful.
Pressing on CHECK ALL AS TFT button all devices will be checked as TFT.
The function of DISPLAY ONLY TFT button is to have a complete list of TFT devices only
(remember: tft device means controller with flag CHECK IF TFT enabled).
Page 10 of 20
solari udine
2.3 TIMES
Through this function the user can define the switch on-off time rules using:
- GLOBAL DEFINITION
- GROUP TIMES
- DEVICE TIMES
Page 11 of 20
solari udine
Pressing GLOBAL DEFINITION button the form printed in FIG.8 will be displayed.
Pressing ASSIGN THE DISPLAYED TIME RULES TO ALL TFT DEVICES button is
possible to assign, automatically, the defined time rules to all devices checked as TFT.
Page 12 of 20
solari udine
Page 13 of 20
solari udine
Pressing GROUP TIMES button the form printed in FIG.10 will be displayed.
After the selection of the GROUP (using the combo box GROUP NAME) the time-rules fields
will be displayed.
For the meaning of each field refer to the table in section 2.3.1.
Pressing ASSIGN THE DISPLAYED TIME RULES TO ALL TFT DEVICES BELONGING TO THE SELECTED
GROUP button is possible to assign, automatically, the defined time rules to all devices related
to the selected group.
Page 14 of 20
solari udine
Pressing DEVICE TIMES button the form printed in FIG.11 will be displayed.
After the selection of the DEVICE (using the combo box DEVICE NAME) the time-rules fields
will be displayed.
For the meaning of each field refer to the table in section 2.3.1.
Pressing CONFIRM button is possible to assign the defined time rules to the selected
devices, overwriting (only for that device) global or group definitions (if present).
Page 15 of 20
solari udine
Pressing LOAD NEW CONFIGURATION button the form printed in FIG.12 will be
displayed.
As shown in the alarm box message this procedure can be very dangerous, because will
delete all the device time-rules previously defined and all the relationship between device and
group.
All groups, global time definition and group time definition WILL NOT BE DELETED.
Page 16 of 20
solari udine
- CHECK IF TFT
- GROUP
- SWITCH OFF
- SWITCH ON
- WEEKLY FREQUENCY
- ENA / DIS
st
- the 1 time (after the installation)
If in the peripheral system configuration the number of TFT devices is greater than the
number of other devices the button CHECK ALL AS TFT can be helpful.
Page 17 of 20
solari udine
Remember!
Page 18 of 20
solari udine
2.5 EMERGENCY
This function, useful in case of emergency conditions, handles the 3 following possibilities:
2.5.1 - Force immediate switch on for all TFT devices (and disable time rules)
Send to all devices checked as TFT the command in order to SWITCH ON IMMEDIATELY
the lamps.
The switch on-off time rules defined for each device will be disabled.
Page 19 of 20
solari udine
Pressing PROCEED button the selected operation will be performed, while pressing EXIT
button the selected operation will be aborted.
(*) After pressing PROCEED button wait some seconds before to see de return message.