Events Triggered by UE: Inter-frequency measurement reporting criteria [25.331, 10.3.7.

19]
The triggering of the event-triggered reporting for an inter-frequency measurements. All events concerning interfrequency measurements are labelled 2x where x is a,b,c, ... Event 2a: Change of best frequency. Event 2b: The estimated quality of the currently used frequency is below a certain threshold and the estimated quality of a non-used frequency is above a certain threshold. Event 2c: The estimated quality of a non-used frequency is above a certain threshold. Event 2d: The estimated quality of the currently used frequency is below a certain threshold. Event 2e: The estimated quality of a non-used frequency is below a certain threshold. Event 2f: The estimated quality of the currently used frequency is above a certain threshold.

Intra-frequency measurement reporting criteria


The triggering of the event-triggered reporting for an intra-frequency measurement. All events concerning intrafrequency measurements are labelled 1x where x is a, b, c. Event 1a: A Primary CPICH enters the Reporting Range (FDD only). Event 1b: A Primary CPICH leaves the Reporting Range (FDD only). Event 1c: A Non-active Primary CPICH becomes better than an active Primary CPICH (FDD only). Event 1d: Change of best cell (FDD only). Event 1e: A Primary CPICH becomes better than an absolute threshold (FDD only). Event 1f: A Primary CPICH becomes worse than an absolute threshold (FDD only). Event 1g: Change of best cell in TDD. Event 1h: Timeslot ISCP below a certain threshold (TDD only). Event 1i: Timeslot ISCP above a certain threshold (TDD only). Event 1j: A Non-active E-DCH but active DCH Primary CPICH becomes better than an active E-DCH Primary CPICH (FDD only).

Inter-RAT measurement reporting criteria


The triggering of the event-triggered reporting for an inter-RAT measurement. All events concerning inter-RAT measurements are labelled 3x where x is a,b,c, ... Event 3a: The estimated quality of the currently used UTRAN frequency is below a certain threshold and the estimated quality of the other system is above a certain threshold. Event 3b: The estimated quality of other system is below a certain threshold. Event 3c: The estimated quality of other system is above a certain threshold. Event 3d: Change of best cell in other system.

UE internal measurement reporting criteria


The triggering of the event-triggered reporting for a UE internal measurement. All events concerning UE internal measurements are labelled 6x where x is a, b, c. In TDD, the events 6a - 6d are measured and reported on timeslot basis. Event 6a: The UE Transmitted Power becomes larger than an absolute threshold Event 6b: The UE Transmitted Power becomes less than an absolute threshold Event 6c: The UE Transmitted Power reaches its minimum value Event 6d: The UE Transmitted Power reaches its maximum value Event 6e: The UE RSSI reaches the UEs dynamic receiver range Event 6f (FDD): The UE Rx-Tx time difference for a RL included in the active set becomes larger than an absolute threshold Event 6f (1.28 Mcps TDD): The time difference indicated by T ADV becomes larger than an absolute threshold Event 6g: The UE Rx-Tx time difference for a RL included in the active set becomes less than an absolute threshold

Quality measurement reporting criteria


Event 5a: Number of bad CRCs on a certain transport channel exceeds a threshold.