Sie sind auf Seite 1von 65

www.moeller.co.

uk

Industrial Switchgear Short Form Catalogue 2005/2006

Think future. Switch to green.

Moeller Market leaders in industrial switchgear Moeller has been at the forefront of switching, protecting and controlling motors for over 100 years. Setting standards with DIL contactors and PKZ motor-protective circuit-breakers, and developing innovative automation systems, such as the multi-functional easy intelligent relay, too. From transformers to pushbuttons, the standard versions of most Moeller devices are approved for use throughout the world. Specified and used across a wide variety of industries from food processing to packaging from woodworking to waste disposal Moeller components range from simple pushbuttons to plcs and touch screens communicating via industry-standard open networks. With 350 sales offices in more than 80 countries, Moeller can meet the needs of customers and end users wherever they are. In the UK, Moeller sales engineers support and advise OEMs, panel builders and end users, in partnership with Moellers network of Key Dealers. Their expertise is enhanced by a team of automation and key account engineers, specialising in intelligent process control solutions. Our technical support staff are on hand to help select the right component for an application. In-depth product support is provided by our product management team, working closely with Moeller engineers and factories around the world. Moellers UK distribution centre, in Aylesbury in Buckinghamshire, holds over 4,000 line items in stock. This ensures most commonly used components can be met from stock, achieving more than 98% on-time delivery performance. This catalogue includes Moellers most popular items in the UK market, and represents just a small part of our range. For more technical information on any items, or for details of our complete range of switchgear and automation products, please visit www.moeller.co.uk/online_catalogue.htm or call the Moeller literature line on 01296 310321 and ask for a copy of our Industrial Switchgear (HPL0211-2004/2005) or Industrial Automation and Drives (HPL0213-2004/2005) catalogues. Moeller Electric Ltd. P. O. Box 35 Gatehouse Close Aylesbury Buckinghamshire HP19 8DH Tel 01296 393322 Fax 01296 421854 www.moeller.co.uk Direct Sales Ordering Tel 01296 397400 Fax 01296 392413 Email sales@moeller.co.uk Technical Support Tel 01296 310323 Fax 01296 392413 Email support@moller.co.uk

Industrial Switchgear Short Form Catalogue 2005/2006

Control circuit devices (RMQ-Titan and FAK)

Drives (DF5, DF6)

37

Signal towers (SL)

13

Semiconductor contactors and softstarters (DS4)

40

Position switches (LS-Titan)

16

Insulated enclosures (CI-K)

42

easy control relays and MFD-Titan multi-function display

19

Switch-disconnectors P, rotary switches T

43

Electronic timers & relays (DIL ET, ETR)

24

Motor-protective circuit-breakers (PKZM01, 0, 4)

47

Contactors and overloads (xStart)

25

Miniature circuit-breakers (FAZ, PLSM, PFIM, PKNM, Z-SCH)

53

Enclosed starters

35

Moulded case circuit-breakers (NZM1, 2, 3, 4) Switch-disconnectors (PN, N)

59

Index by part number Rated current of three-phase motors

64 Inside back cover

Control circuit devices System overview


Moeller SK0211-1149GB

Contact blocks 4-way selector switch

Contact blocks

4-way pushbutton

Fixing adaptor

Enclosure

4-way joystick

Emergency-Stop actuator

Contact blocks

Pushbutton actuator

Complete legend plate

Button plate/ button lens Selector switch actuator Telescopic clip

Key-operated actuator

Centring adaptor

Contact block

Indicator light Fixing adaptor Buzzer Acoustic indicator Top-hat rail adaptor

Contact blocks

Acoustic indicator cap

Potentiometer

Front rings

(Titanium appearance standard, black and gold options)

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Control circuit devices RMQ-TITAN

Fixing adaptor

Pushbutton actuators

Moeller SK0211-1149GB

Competitively priced, Moellers RMQ-Titan range comprises pushbuttons, selector switches, joysticks, Emergency-Stop and key-operated actuators. Control circuit devices RMQ-TITAN The system includes a variety of indicator lights and illuminated pushbuttons in white, red, yellow, blue and green. They are available in two voltage ranges 12 30 V AC/DC and 85 - 264 V AC covering all standard applications. Meeting all relevant international standards, this attractive, co-ordinated product range will add significant value to any machine or system. Features and benefits Ergonomic design ensuring ease of operation and bright illumination. IP66 degree of protection as standard (many devices IP67, IP69K) for use in the harshest of industrial environments. Vibration resistant LEDs giving a minimum life of 100,000 hours for improved reliability and high integrity. Fitting in the standard 22.5 mm hole, the snap fitting modular system saves both assembly and fitting time.

Description Pushbutton actuators, IP67, 69K Actuator flush

Button plate

Part number

Spring-return

Without

M22-D-X M22-D-S M22-D-W M22-D-R M22-D-G M22-D-Y M22-D-B M22-D-R-X0 M22-D-G-X1 M22-D-S-X0

Actuator extended

Spring-return

M22-DH-S M22-DH-W M22-DH-R M22-DH-G M22-DH-Y M22-DH-B

Pushbutton actuators, Emergency-Stop actuators

Moeller SK0211-1149GB Description Illuminated pushbutton actuators, IP67, IP69K Actuator flush Spring-return Button plate Part number

M22-DL-R M22-DL-G M22-DL-Y M22-DL-B Actuator extended Spring-return M22-DLH-W M22-DLH-R M22-DLH-G M22-DLH-Y M22-DLH-B Double actuators, IP66 With indicator light, white lens

Spring-return

M22-DDL-GR-X1/X0

M22-DDL-GR-GB1/GB0

M22-DDL-WS-X1/X0

Emergency-Stop actuators, IP66, IP69K Non-illuminated, pull to release Illuminated, pull to release Non-illuminated, twist to release Illuminated, twist to release Key to release Sealable shroud, IP65 Mushroom actuators, IP67, 69K Spring-return M22-DP-S M22-DP-R M22-DP-R-X0 M22-DP-G M22-DP-Y Pushbutton, 4-way, IP66 Use M22-A4 fixing adaptor Transparent M22-PV M22-PVL M22-PVT M22-PVLT M22-PVS M22-PL-PV

Spring-return in all positions, 4 direction arrows

M22-D4-S-X7

Spring-return in all positions, no inscription

M22-D4-S

Control circuit devices RMQ-TITAN

M22-DL-W

Joysticks, selector switch actuators

Moeller SK0211-1149GB Description Joysticks, 4 positions, IP66 Use M22-A4 fixing adaptor Colour Part number

Control circuit devices RMQ-TITAN

Gated spring-return in all positions Gated stay-put in all positions

M22-WJ4 M22-WRJ4

Joystick labels

Blank Arrows in each position

M22-XCK M22-XCK1 M22-W M22-WR

Selector switch actuators, 2 positions, IP66 Rotary button Spring-return Stay-put

Thumb-grip

Spring-return Stay-put

M22-WK M22-WRK

Selector switch actuators, 3 positions, IP66 Rotary button Spring-return Stay-put

M22-W3 M22-WR3

Thumb-grip Key-operated actuators, IP66 2 positions

Spring-return Stay-put Spring-return Stay-put

M22-WK3 M22-WRK3 M22-WS M22-WRS

3 positions Set of coding adapters

Stay-put For converting between stay-put, spring-return and key release function For converting between stay-put and spring-return function

M22-WRS3 M22-XC-R M22-XC-Y

Indicator lights, illuminated selector switches, contact blocks

Moeller SK0211-1149GB Description Indicator lights, IP67, 69K M22-L-R M22-L-G M22-L-Y M22-L-B Extended, conical M22-LH-W M22-LH-R M22-LH-G M22-LH-Y M22-LH-B Illuminated selector switch actuators, thumb-grip, IP66 2 positions Spring-return Colour Part number

M22-WLK-W M22-WLK-R M22-WLK-G M22-WLK-Y M22-WLK-B

Stay-put

M22-WRLK-W M22-WRLK-R M22-WRLK-G M22-WRLK-Y M22-WRLK-B

3 positions Spring-return M22-WLK3-W M22-WLK3-R M22-WLK3-G M22-WLK3-Y M22-WLK3-B Stay-put M22-WRLK3-W M22-WRLK3-R M22-WRLK3-G M22-WRLK3-Y M22-WRLK3-B Fixing adapters Fixing adapter (front fixing) for 3 contact-/LED elements Fixing adapter (front fixing) for 4 contact blocks M22-A M22-A4

Contact blocks Front fixing Base fixing

1 N/O 1 N/C 1 N/O 1 N/C

M22-K10 M22-K01 M22-KC10 M22-KC01

Control circuit devices RMQ-TITAN

Flush

M22-L-W

LED elements, enclosures

Moeller SK0211-1149GB Description LED elements with screw terminals Colour Part number

Control circuit devices RMQ-TITAN

Use a white LED with a yellow indicator. Front fixing 12 30 V AC/DC M22-LED-W M22-LED-R M22-LED-G M22-LED-B 85 264 V AC M22-LED230-W M22-LED230-R M22-LED230-G M22-LED230-B Base fixing 12 30 V AC/DC M22-LEDC-W M22-LEDC-R M22-LEDC-G M22-LEDC-B 85 264 V AC M22-LEDC230-W M22-LEDC230-R M22-LEDC230-G M22-LEDC230-B

Colour Number of ways Surface mounting enclosures, IP67, IP69K With high-grade steel screws Enclosure base: anthracite 1

Part number

M22-IY1

1 2 3 4 6 Flush mounting plates 1 2 3

M22-I1 M22-I2 M22-I3 M22-I4 M22-I6

M22-E1 M22-E2 M22-E3

Foot and palm switches, potentiometers

Moeller SK0211-1149GB Impedance R kO Part number

Description

Colour Enclosure

Button

Pushbutton stations, IP67 Emergency-Stop button with 1 N/O 1N/C contact Key release Emergency-Stop button with 1 N/O 1N/C contact 2-position key switch with 1 N/O 1N/C contact With 1 N/O 1 N/C contact With 1 N/O 1 N/C contact Stop/Start with 2 N/O 2 N/C contacts 3-way with 3 N/O 3 N/C contacts Foot and palm switches, IP67, IP69K Spring-return M22-PV/KC11/IY M22-PVS/KC11/IY M22-WRS/KC11/I M22-D-G-X1/KC11/I M22-D-R-X0/KC11/I M22-I2-M1 M22-I3-M1

1 N/O 1 N/C 1 N/O 1 N/C

FAK-S/KC11/I FAK-R/KC11/I

Stay-put Pull to release Emergency-Stop actuator

1 N/O 1 N/C 1 N/C

FAK-R/V/KC11/IY FAK-R/V/KC01/IY

Potentiometers, IP66 1 4.7 10 47 100 470 M22-R1K M22-R4K7 M22-R10K M22-R47K M22-R100K M22-R470K

Control circuit devices RMQ-TITAN

10

Accessories for control circuit devices

Moeller SK0211-1149GB Description Accessories Combination box spanner For fixing RMQ front elements M22-MS Button plate Part number

Control circuit devices RMQ-TITAN

Blanking plug, IP67, IP69K M22-B

Actuator diaphragms for IP67, IP69K, silicone Additional protection for pushbutton actuators M22-T-D

Additional protection for double pushbutton actuators

M22-T-DD

Telescopic mounting clip For three contact/LED elements with base fixing, including centring adapter M22-TC

Compact acoustic indicator, IP40 Front black, without buzzer, BA 9s socket M22-AMC

Buzzer for acoustic indicator Continuous tone, 18 30 V AC/DC Pulsed tone, 18 30 V DC Top-hat rail adapter Top-hat rail IEC/EN 60715 for use with front fixing components M22-IVS M22-XAM M22-XAMP

Legend holders, legend plates

11

Moeller SK0211-1149GB Inscription Complete legend plates, IP66 START OFF ON RUN FAULT OFF ON MAN. AUTO MAN. 0 AUTO Legend holder without label, IP66 Round, black For actuators, 30 x 50 mm For double actuators, 30 x 75 mm Insert plate for legend holder Emergency-Stop labels, IP66 Lettering black, 30 X 50 mm Blank Emergency-Stop Blank 50 X 50 mm Emergency-Stop in 4 languages Aluminium M22S-ST-GB1 M22S-ST-GB5 M22S-ST-GB6 M22S-ST-GB7 M22S-ST-GB8 M22S-ST-GB10 M22S-ST-GB11 M22S-ST-GB12 Colour Part number

M22S-ST-X M22S-STDD-X M22-XST M22-XZK-GB99 M22-XZK M22-XYK1

Diameter = 90 mm

Emergency-Stop in 4 languages Blank

M22-XAK1 M22-XAK

Diameter = 60 mm

Emergency-Stop in 4 languages

M22-XBK1

Control circuit devices RMQ-TITAN

Round, black, 30 x 50 mm

STOP

M22S-ST-GB0

12

Button plates

Moeller SK0211-1149GB Description Button plates for pushbutton actuators Button plate Part number

Control circuit devices RMQ-TITAN

Flush

M22-XD-S M22-XD-W M22-XD-R M22-XD-G M22-XD-Y M22-XD-B M22-XD-G-X1 M22-XD-R-X0

Extended

M22-XDH-S M22-XDH-W M22-XDH-R M22-XDH-G M22-XDH-Y M22-XDH-B M22-XDH-G-X1 M22-XDH-R-X0

Signal towers System overview


Moeller SK0211-1149GB

13

Continuous light module

Gasket

Caps with grooved lenses for enhanced light distribution Flashing light module Gasket

Strobe light module

Gasket

Acoustic indicator module

Gasket

Gasket Base module

90 metal fixing bracket

Stand with 100 mm spacer

250 mm spacer option

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Signal towers SL

Top cover

14

Signal tower modules

Moeller SK0211-1149GB

Mounted on top of a machine or control panel SL signal towers provide operating staff, working near or at a distance, with information about a machine's operation, stoppage, interruption in material flow or, for example, fault alarms. Consequently any problems or faults can be indicated and resolved quickly. Signal towers SL The user has the choice of four types of indicator: continuous, flashing, or strobe light and/or an audible alarm. Choose between filament bulbs, or LEDs for more critical applications specially shaped lenses ensure excellent visibility from all directions. Features and benefits Individual modules can be combined as required, enabling users to assemble their own combinations. Modules are freely programmable by simply setting jumpers on the module board. Fitting modules together is quick and easy with no tools required simply plug on the bayonet fitting and turn slightly. Rated as standard to IP54, with an IP65 option for use in harsher environments.

Description Base module, IP54 With screw terminals and top cover

Colour

Part number

SL-B

Continous light modules, IP54 Without filament lamp/LED SL-L-B SL-L-G SL-L-R SL-L-W SL-L-Y Flashing light modules, IP54 24 V AC/DC Without filament lamp/LED SL-BL24-B SL-BL24-G SL-BL24-R SL-BL24-W SL-BL24-Y 230 V AC Without filament lamp/LED SL-BL230-B SL-BL230-G SL-BL230-R SL-BL230-W SL-BL230-Y

Signal tower modules, accessories

15

Moeller SK0211-1149GB Description Strobe light module, IP54 230 V AC With flash tube SL-FL230-R SL-FL230-W SL-FL230-Y Colour Part number

Acoustic indicator modules, IP20 Continuous tone 12 36 V AC/DC 110 230 V AC/DC Pulsed tone 12 36 V AC/DC 110 230 V AC/DC Accessories Stand with spacer SL-A24 SL-A110-230

SL-AP24 SL-AP110-230

100 mm 250 mm

SL-F100 SL-F250

Fixing bracket Filament lamps, BA 15d, 5 7 W

90, metal 24 V DC 110 130 V AC 230 V AC 18 30 V AC/DC

SL-FW SL-L24 SL-L130 SL-L230 SL-LED-B SL-LED-G SL-LED-R SL-LED-W SL-LED-Y

Multiple LED, BA 15d

Set of gaskets

For increasing the degree of protection to IP65 (not for the acoustic indicator), 4 gaskets for use with 3 modules

SL-IP65

Signal towers SL

16

Position switches System overview


Moeller SK0211-1149GB
Basic unit

Position switches LS-Titan

Fixing adaptor for RMQ-Titan control circuit devices

Roller lever

Angled roller lever

Rotary lever

Roller plunger Adjustable roller lever Spring-rod Actuating rod

RMQ-Titan front elements

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Basic units for position switches

17

Moeller SK0211-1149GB

All devices are actuated mechanically and, with their positively opening and interlocked opposing contacts, are suitable for use in safety circuits. A unique feature is the ability to combine LS-Titan with pushbutton actuators, selector switches or Emergency-Stop buttons from the RMQ-Titan range. These can simply be snapped on to act as the operating head of the position switch. The LSE (limit switch electronic) has a freely programmable operating point that can be easily set. Just move the plunger from the original position to the new switching position and press the teach-in button with a screwdriver for 1 second. Once the LED flashes at a higher rate, the new position is accepted and is usable. The switching point is freely adjustable within a range of 0.5 to 5.5 mm. Features and benefits Conform to EN 50047, so ensuring interchangeability Modular range of basic units and operating heads are quickly and easily installed with a bayonet catch, offering flexibility of application. Maintenance free and vibration resistant cage clamp terminals

Description Insulated, enclosed units, IP66, rounded plunger Basic units Standard action contacts Make-before-break contacts Snap-action contacts Standard action contacts

Contacts

Part number

1 N/O, 1 N/C 1 N/O, 1 N/C 1 N/O, 1 N/C 2 N/O

LS-11 LS-11D LS-11S LS-20

Basic units with electronically adjustable operating point Indicator light to show status 1 N/O, 1 N/C 2 N/C LSE-11 LSE-02

Metal, enclosed units, IP66, rounded plunger Basic units Standard action contacts Make-before-break contacts Snap-action contacts Standard action contacts Standard action contacts 1 N/O, 1 N/C 1 N/O, 1 N/C 1 N/O, 1 N/C 2 N/O 2 N/C LSM-11 LSM-11D LSM-11S LSM-20 LSM-02

Accessories Fixing adapter

For operation by RMQ-Titan actuators

M22-LS

Position switches LS-Titan

Moellers LS-Titan position switches are quick and easy to install, highly flexible and safe. Rated to IP66, the LS-Titan range is available in two versions: For normal operating conditions in corrosive environments, or in the food industry, the LS versions have a totally insulated housing, whereas the LSM versions in their robust metal enclosures are suited to mechanically harsher environments.

18

Operating heads for position switches

Moeller SK0211-1149GB Operating heads Spring rod (use with snap-action contact only)

Roller lever

Angled roller lever

Roller plunger

Rotary lever

Adjustable roller lever (D = 18 mm)

Actuating rod (insulated)

Actuating rod (metal)

Position switches LS-Titan

Insulated version LS-XL LS-XLA LS-XP LS-XRL LS-XRLA LS-XRR LS-XRRM LS-XS

Metal version LSM-XL LSM-XLA LSM-XP LSM-XRL LSM-XRLA LSM-XRR LSM-XRRM LSM-XS

easy control relays, MFD-Titan multi-function displays System overview


Moeller SK0211-1149GB

19

Stand-alone units easy512

Expansion unit

Expansion unit

Expandable units easy719/721 Coupling unit

Expansion unit Expandable networkable units easy819/822

DE

OK

EASY-LINK-DS data plug


POWER COM-ERR ADR

Network connection to AS-Interface

MFD-Titan I/O module

Network connection to DP PROFIBUS

POW

BUS

MFD-Titan power supply/ CPU

Network connection to CANopen

ERR

Network connection to DeviceNet MFD-Titan display, with or without keypad

MS

NS

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

easy control relays MFD-Titan multi-function displays

ES C

T AL

ES C

20

Introduction to easy and MFD

Moeller SK0211-1149GB

easy control relays MFD-Titan multi-function displays

easy control relays


Moellers market leading range of easy intelligent relays brings timers, relays, inputs and outputs into one compact device that can be easily configured, providing unprecedented levels of flexibility together with considerable savings in commissioning time. Features and benefits Comprehensive range from stand-alone units with a few timing relays and a time switch to networked applications with hundreds of I/O and connection to the revolutionary MFD IP65 panel display Simple circuit diagram entry on the easy unit itself or via the EASY-SOFT drag and drop software. Program download to plug-in EPROM memory module. Instant programming of other similar applications, or simple, secure back up for critical processes. Expansion and networking link up to eight easy control relays via EASY-NET.

MFD multi-function display


The MFD-Titan offers a 60 x 30 mm LCD display in an IP65 housing, designed to match the styling of the RMQ-Titan control circuit devices. An optional keypad enables control functions to be implemented, recipes selected or set point values to be entered directly into the device. Two LEDs on the front of the unit can also be illuminated or flashed to attract attention or indicate machine status. Features and benefits Back-lit display capable of displaying graphics, text, data, time etc. all with brilliant clarity. Incredibly quick and simple installation mounts easily into two standard 22.5 mm holes saving time, tooling and hassle whilst maintaining IP65 degree of protection. Customised inscription optional on both the function buttons and the display unit itself. Simple control and visualisation set-up utilising all of the function blocks available with the easy800 and the simplicity of EASY-SOFT-PRO.

easy control relays

Inputs Digital

Analog

Outputs Relay (8 amp.)

Transistor

Analog

Additional features Display & Real time keypad clock


Part number Supply

Stand-alone base units (easy500) 8 8 8 8 8 8 8 8 8 8 8 8 4 4 4 4 4 4 4 4 4 4 4 4


2 2 2 2 2

110/240 V AC 110/240 V AC 24 V AC 12 V DC 24 V DC 24 V DC 24 V DC 110/240 V AC 24 V AC 12 V DC 24 V DC 24 V DC

EASY512-AC-R EASY512-AC-RC EASY512-AB-RC EASY512-DA-RC EASY512-DC-R EASY512-DC-RC EASY512-DC-TC EASY512-AC-RCX EASY512-AB-RCX EASY512-DA-RCX EASY512-DC-RCX EASY512-DC-TCX

2 2 2 2

easy control relays

21

Moeller SK0211-1149GB Inputs Digital Expandable base units (easy700) 12 12 12 12 12 4 4 4 4 6 6 6 6 8


Analog

Outputs Relay (8 amp.)

Transistor

Analog

Additional features Display & Real time keypad clock

Part number Supply

110/240 V AC 24 V AC 24 V DC 12 V DC 24 V DC

EASY719-AC-RC EASY719-AB-RC EASY719-DC-RC EASY719-DA-RC EASY721-DC-TC

12 12 12 12 12

4 4 4 4

6 6 6 6 8

110/240 V AC 24 V AC 24 V DC 12 V DC 24 V DC

EASY719-AC-RCX EASY719-AB-RCX EASY719-DC-RCX EASY719-DA-RCX EASY721-DC-TCX

Expandable, networkable base units (easy800) 12 12 12 12 12

4 4 4 4

6 6 6 8 8

1 1

110/240 V AC 24 V DC 24 V DC 24 V DC 24 V DC

EASY819-AC-RC EASY819-DC-RC EASY820-DC-RC EASY821-DC-TC EASY822-DC-TC

12 12 12 12 12

4 4 4 4

6 6 6 8 8

1 1

110/240 V AC 24 V DC 24 V DC 24 V DC 24 V DC

EASY819-AC-RCX EASY819-DC-RCX EASY820-DC-RCX EASY821-DC-TCX EASY822-DC-TCX

Expansion units (for easy700, easy800) 12 12 12

6 6 8

110/240 V AC 24 V DC 24 V DC

EASY618-AC-RE EASY618-DC-RE EASY620-DC-TE

EASY202-RE

easy control relays MFD-Titan multi-function displays

22

MFD-Titan multi-function displays

Moeller SK0211-1149GB

easy control relays MFD-Titan multi-function displays

MFD-Titan multi-function displays Displays

Description

Part number

Display with graphical backlit screen Display with graphical backlit screen and keypad

MFD-80 MFD-80-B

Power supply/CPU 24 V DC, with advanced functions (no EASY-NET) 24 V DC, with advanced functions and EASY-NET 100 240 V AC, with advanced functions (no EASY-NET) 100 240 V AC, with advanced functions and EASY-NET MFD-CP8-ME MFD-CP8-NT MFD-AC-CP8-ME MFD-AC-CP8-NT

Inputs Digital I/O modules 12 12 12 12 12

Analog

Outputs Relay (8 amp.)

Part number Transistor Analog Supply

4 4 4 4

4 4 4 4 4

1 1

24 V DC 110/240 V AC 24 V DC 24 V DC 24 V DC

MFD-R16 MFD-AC-R16 MFD-RA17 MFD-T16 MFD-TA17

easy control relays, MFD-Titan multi-function displays Accessories


Moeller SK0211-1149GB Description Communication Coupling unit enabling remote expansion PC connection cable PC connection cable Cable for EASY-NET connection Plug for EASY-NET bus termination Power supplies 24 V DC, 1.25 A Dual output: 24 V DC, 250 mA and 12 V DC, 20 mA EASY400-POW EASY200-POW Part number

23

up to 30 m For easy500/700 For easy800 and MFD units 30 cm 2 required

EASY200-EASY EASY-PC-CAB EASY800-PC-CAB EASY-NT-30 EASY-NT-R

Memory modules For easy500/700 For easy800 Software For easy500/700 For easy500/700/800 and MFD displays Accessories Mounting rail IP65 display repeater IP65 display repeater For MFD expansion For easy500 For easy800 EASY-SOFT-BASIC EASY-SOFT-PRO MFD-TS-144 MFD-CP4-500 MFD-CP4-800 EASY-M-32K EASY-M-256K

Manuals easy500/700 instruction manual easy800 instruction manual MFD instruction manual

AWB2528-1508-GB AWB2528-1423-GB AWB2528-1480GB

easy control relays MFD-Titan multi-function displays

24

Electronic timing relays

Moeller SK0211-1149GB

ETR4 timing relays control machines and systems to an accuracy of a hundredth of a second across a wide range of timing functions. Electronic timing relays DIL ET, ETR4 The relays in the ETR4 range are only 22.5 mm wide. When combined with contactors and contactor relays they offer an ideal space-saving solution for virtually all timing requirements. The DIL ET timing relays are 45 mm wide, so matching the xStart contactors up to DILM12. The ETR4-69 and ETR4-70 are extremely versatile with nine selectable functions and ten timing ranges. Features and benefits Compact design saves panel space. Simple fitting and setting reduce assembly and commissioning time. Extensive time ranges enable use in most processes. Multi-function versions offer adaptability. Clear dial settings and LED status indication provide accurate information. International approvals ensure acceptance.

Time range (See table below) 24 V 240 V AC/DC, 50/60 Hz 45 mm wide A B B

Description

Part number

On-delayed On-delayed Multi-function with connection for remote potentiometer

DILET11-30-A DILET11-M-A DILET70-A

24 V 240 V AC/DC, 50/60 Hz 22.5 mm wide D C D D On-delayed Star-delta Multi-function Multi-function with connection for potentiometer and 2 C/O contacts ETR4-11-A ETR4-51-A ETR4-69-A ETR4-70-A

346 V 440 V, 50/60 Hz 22.5 mm wide D C D On-delayed Star-delta Multi-function ETR4-11-W ETR4-51-W ETR4-69-W

Time range A 1.5 30 s. B 0.05 0.15 0.5 3 0.15 0.5 3 0.15 0.5 3 1 s. 3 s. 10 s. 60 s. 3 min. 10 min. 60 min. 3 hr. 10 hr. 60 hr. C 3 60 s. D 0.05 0.15 0.5 1.5 5 15 1.5 15 1.5 5 1 s. 3 s. 10 s. 30 s. 100 s. 300 s. 30 min. 300 min. 30 hr. 100 hr.

Contactors and overloads System overview


Moeller SK0211-1149GB
Insulated surface mounting enclosure with Emergency-Stop button Insulated flush mounting enclosure

25

Current limiter Pushbutton motor-protective circuit-breaker Shunt + undervoltage trip Top-hat rail adaptor Side-mounted auxiliary contact Busbar adaptor

Early-make auxiliary contact

Front auxiliary contact

Trip-indicating auxiliary contact Motor starter with toolless plug connector technology

Door coupling rotary handle and shaft

Rotary action motorprotective circuit-breaker

Early-make auxiliary contact

Front auxiliary contact

Toolless plug connector (mechanical link)

Connector (electrical link)

Side-mounted auxiliary contact

Toolless plug-in connector

Side-mounted auxiliary contact

Base mounting bracket

Contactor up to 12 A

Contactor up to 32 A

Contactor up to 65 A

Contactor up to 150 A

Overload relay up to 32 A

Overload relay up to 65 A Suppressor Suppressor Overload relay for direct mounting Overload relay for separate mounting

Top-mounted auxiliary contacts

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Contactors and overloads xStart

26

Mini contactor relays

Moeller SK0211-1149GB

Contactors and overloads xStart

With just four frame sizes up to 150 A, the new DILM contactors are significantly more compact than their predecessors, and include an integral auxiliary contact for contactors up to 32 A. They are perfectly complemented by the DILA contactor relays available as basic units with four contact paths, they can be extended to eight contacts by using top mounting auxiliary modules. The motor starter combinations comprise a PKZM0 motor-protective circuit-breaker (see page 49) and xStart contactor. Both devices are mechanically interconnected via a plug-in element. The electrical connection is provided by a plug-in contact element, using the unique toolless plug connection technology. Features and benefits Reduced power consumption coils mean lower heat dissipation and smaller control transformers. Coil terminals on the front face simplify connection. Twin box terminals allow the secure connection of differing cable crosssections and facilitate the 'looping' of cables. Voltage tolerance of the coils exceeds IEC/EN 60947 standard, ensuring effective protection in the event of under and over voltage. Identical frame size for AC and DC devices simplifies engineering. DC devices have integral suppressors and low-consumption coils, that can be operated directly from PLC outputs saving time and expense. Unique toolless plug connection for MSC motor starters significantly reduces installation time.

Contacts Mini contactor relays AC coil 2 N/O + 2 N/C 2 N/O + 2 N/C 2 N/O + 2 N/C 3 N/O + 1 N/C 3 N/O + 1 N/C 3 N/O + 1 N/C 4 N/O 4 N/O 4 N/O DC coil 2 N/O + 2 N/C 3 N/O + 1 N/C 4 N/O Auxiliary contact modules Top mounting 1 N/O + 1 N/C 2 N/O + 2 N/C 3 N/O + 1 N/C

Part number

DILER-22(24V50HZ) DILER-22(110V50HZ) DILER-22(230V50HZ) DILER-31(24V50HZ) DILER-31(110V50HZ) DILER-31(230V50HZ) DILER-40(24V50HZ) DILER-40(110V50HZ) DILER-40(230V50HZ) DILER-22-G(24VDC) DILER-31-G(24VDC) DILER-40-G(24VDC)

11DILE 22DILE 31DILE

Contactor relays

27

Moeller SK0211-1149GB Contacts Contactor relays AC coil 2 N/O + 2 N/C 2 N/O + 2 N/C 2 N/O + 2 N/C 3 N/O + 1 N/C 3 N/O + 1 N/C 3 N/O + 1 N/C 4 N/O 4 N/O 4 N/O DC coil 2 N/O + 2 N/C 3 N/O + 1 N/C 4 N/O Auxiliary contact modules Top mounting 1 N/O + 1 N/C DILA-XHI11 DILA-22(24VDC) DILA-31(24VDC) DILA-40(24VDC) DILA-22(24V50HZ) DILA-22(110V50HZ) DILA-22(230V50HZ) DILA-31(24V50HZ) DILA-31(110V50HZ) DILA-31(230V50HZ) DILA-40(24V50HZ) DILA-40(110V50HZ) DILA-40(230V50HZ) Part number

3 N/O + 1 N/C 2 N/O + 2 N/C 4 N/O

DILA-XHI31 DILA-XHI22 DILA-XHI40

Contactors and overloads xStart

28

Mini contactors

Moeller SK0211-1149GB Contacts For use with Part number

Contactors and overloads xStart

Mini contactors up to 4 kW, 3-pole AC coil 1 N/O 1 N/O 1 N/O 1 N/O 1 N/C 1 N/C 1 N/C 1 N/C DC coil 1 N/O 1 N/C Auxiliary contact modules Top mounting 1 N/O + 1 N/C 2 N/O + 2 N/C DILEM DILEM 11DILEM 22DILEM DILEM-10-G(24VDC) DILEM-01-G(24VDC) DILEM-10(24V50HZ) DILEM-10(110V50HZ) DILEM-10(230V50HZ) DILEM-10(400V50HZ) DILEM-01(24V50HZ) DILEM-01(110V50HZ) DILEM-01(230V50HZ) DILEM-01(400V50HZ)

Accessories Varistor suppressor DILEM AC, 24 48 V DILEM AC, 110 250 V VGDILE48 VGDILE250

Mechanical interlock DILEM MVDILE

RC suppressor DILEM AC, 24 48 V DILEM AC, 110 250 V RCDILE48 RCDILE250

Contactors

29

Moeller SK0211-1149GB Cross reference for new contactors DILM range, established system Basic units Auxiliary Rated contacts operational current Ie, AC-3 400 V A DIL00M-10 DIL00M-01 DIL00AM-10 DIL00AM-01 DIL0M DIL0AM DIL1M DIL1AM DIL2M DIL2AM 1 N/O 1 N/C 1 N/O 1 N/C 0 0 0 0 0 0 8.8 8.8 12 12 15.5 22.5 30 36 43 58

Rating AC-3 400 V

kW 3 4 5.5 7.5 11 15 18.5 22 30

Conventional thermal current Ith = Ie, AC-1 40 C A 22 22 22 22 38 38 60 60 98 98

Rated operational current Ie, AC-3 400 V A 7 7 9 9 12 12 18 18 25 25 32 32 40 50 65

Conventional thermal current Ith = Ie, AC-1 40 C A 22 22 22 22 22 22 40 40 45 45 45 45 60 70 85

DILM7-10 DILM7-01 DILM9-10 DILM9-01 DILM12-10 DILM12-01 DILM17-10 DILM17-01 DILM25-10 DILM25-01 DILM32-10 DILM32-01 DILM40 DILM50 DILM65

1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 1 N/O 1 N/C 0 0 0

kW rating (AC-3, 400 V) Contactors AC coil 3

Auxiliary contacts

Part number

1 N/O 1 N/O 1 N/O 1 N/O 1 N/C

DILM7-10(24V50HZ) DILM7-10(110V50HZ) DILM7-10(230V50HZ) DILM7-10(400V50HZ) DILM7-01(230V50HZ)

DC coil 3 AC coil 4 1 N/O 1 N/O 1 N/O 1 N/O 1 N/C DILM9-10(24V50HZ) DILM9-10(110V50HZ) DILM9-10(230V50HZ) DILM9-10(400V50HZ) DILM9-01(230V50HZ) 1 N/O 1 N/C DILM7-10(24VDC) DILM7-01(24VDC)

DC coil 4 AC coil 5.5 1 N/O 1 N/O 1 N/O 1 N/O 1 N/C DILM12-10(24V50HZ) DILM12-10(110V50HZ) DILM12-10(230V50HZ) DILM12-10(400V50HZ) DILM12-01(230V50HZ) 1 N/O 1 N/C DILM9-10(24VDC) DILM9-01(24VDC)

DC coil 5.5 1 N/O 1 N/C DILM12-10(24VDC) DILM12-01(24VDC)

Contactors and overloads xStart

xStart DILM range, new system Basic units Auxiliary contacts

30

Contactors

Moeller SK0211-1149GB kW rating (AC-3, 400 V) Auxiliary contacts Part number

Contactors and overloads xStart

Contactors AC coil 7.5 1 N/O 1 N/O 1 N/O 1 N/O DILM17-10(24V50HZ) DILM17-10(110V50HZ) DILM17-10(230V50HZ) DILM17-10(400V50HZ)

DC coil 7.5 AC coil 11 1 N/O 1 N/O 1 N/O 1 N/O DILM25-10(24V50HZ) DILM25-10(110V50HZ) DILM25-10(230V50HZ) DILM25-10(400V50HZ) 1 N/O DILM17-10(RDC24)

DC coil 11 1 N/O DILM25-10(RDC24)

Contactor application ratings

DIL Rated operational voltage AC-3 Rated power of three-phase motor 50 60 Hz 380 V 400 V AC-4 Rated power of three-phase motor 50 60 Hz 380 V 400 V AC-1 Rated power with resistive load, 40 C 380 V 400 V Conventional thermal free air current Ith = Ie open at 60 C up to 690 V

M7 kW

M9 kW

M12 kW

5.5

2.2

2.5

14 A 22

14 A 22

14 A 22

Contactors

31

Moeller SK0211-1149GB kW rating (AC-3, 400 V) Contactors AC coil 15 1 N/O 1 N/O 1 N/O 1 N/O DILM32-10(24V50HZ) DILM32-10(110V50HZ) DILM32-10(230V50HZ) DILM32-10(400V50HZ) Auxiliary contacts Part number

DC coil 15 AC coil 18.5 DILM40(24V50HZ) DILM40(110V50HZ) DILM40(230V50HZ) DILM40(400V50HZ) DILM50(24V50HZ) DILM50(110V50HZ) DILM50(230V50HZ) DILM50(400V50HZ) DILM65(24V 50HZ) DILM65(110V50HZ) DILM65(230V50HZ) DILM65(400V50HZ) 1 N/O DILM32-10(RDC24)

22

30

DC coil 18.5 22 30 DILM40(RDC24) DILM50(RDC24) DILM65(RDC24)

M17 kW

M25 kW

M32 kW

M40 kW

M50 kW

M65 kW

7.5

11

15

18.5

22

30

4.5

10

12

26 A 40

29 A 45

29 A 45

39 A 60

46 A 70

55 A 85

Contactors and overloads xStart

32

Auxiliary contactors, accessories

Moeller SK0211-1149GB Contacts For use with Part number

Contactors and overloads xStart

Auxiliary contact modules (AC-1, Ith = Ie, 10 A) Top mounting 1 N/O + 1 N/C 2 N/C 2 N/O + 2 N/C 2 N/O 1 N/O + 1 N/C 2 N/C DILM9 DILM32 DILM32-XHI11 DILM32-XHI02 DILM32-XHI22 DILM150-XHI20 DILM150-XHI11 DILM150-XHI02

DILM40 DILM65

4 N/O 3 N/O + 1 N/C 2 N/O + 2 N/C 1 N/O + 3 N/C 4 N/C 2 N/O (1 EM) + 2 N/C (1 LB)

DILM150-XHI40 DILM150-XHI31 DILM150-XHI22 DILM150-XHI13 DILM150-XHI04 DILM150-XHIV22

Side mounting 1 N/O + 1 N/C 1 N/O (1 EM) + 1 N/C (1 LB) 1 N/O + 1 N/C DILM40 DILM65 DILM40 DILM65 DILM40 DILM65 alongside SI module DILM1000-XHI11-SI DILM1000-XHIV11-SI DILM1000-XHI11-SA

Accessories Paralleling links DILM7 DILM12 DILM12-XP1

DILM17 DILM32 DILM40 DILM65

DILM32-XP1 DILM65-XP1

Star-delta wiring links DILM7 DILM12 DILM17 DILM32 Reversing wiring links DILM7 DILM12 DILM17 DILM32 DILM12-XRL DILM32-XRL DILM12-XSL DILM32-XSL

Accessories, toolless plug connectors

33

Moeller SK0211-1149GB For use with Accessories Star points DILM7 DILM12 DILM17 DILM32 DILM40 DILM65 Mechanical interlocks DILM7 DILM12 DILM17 DILM32 DILM40 DILM65 System for direct connection between PKZM0 and DILM contactors DOL toolless plug connection PKZM0 + DILM7/9/12 DILM12-XMV DILM32-XMV DILM65-XMV DILM12-XS1 DILM32-XS1 DILM65-XS1 Part number

PKZM0-XDM12

DOL starter connection kit Reversing toolless plug connection

PKZM0 + DILM17/25/32 PKZM0 + DILM7/9/12-01

PKZM0-XDM32 PKZM0-XRM12

Reversing starter connection kit

PKZM0 + DILM17/25/32

PKZM0-XRM32

Contactors and overloads xStart

34

Overload relays

Moeller SK0211-1149GB Cross reference for new overloads Setting range Ir A 0.1 0.16 0.16 0.24 0.24 0.4 0.4 0.6 0.6 1 1 1.6 1.6 2.4 2.4 4 46 6 10 9 12 10 16 16 24 24 32 6 10 10 16 16 24 24 40 40 57 50 65 Setting range of overload trip

Contactors and overloads xStart

Z00, Z1 range, established system

xStart ZB range, new system

Z00-0,16 Z00-0,24 Z00-0,4 Z00-0,6 Z00-1,0 Z00-1,6 Z00-2,4 Z00-4 Z00-6 Z00-10 Z00-16 Z00-24 Z1-10 Z1-16 Z1-24 Z1-40 Z1-57 Z1-63 For use with contactors

ZB12-0,16 ZB12-0,24 ZB12-0,4 ZB12-0,6 ZB12-1,0 ZB12-1,6 ZB12-2,4 ZB12-4 ZB12-6 ZB12-10 ZB12-12

ZB32-0,16 ZB32-0,24 ZB32-0,4 ZB32-0,6 ZB32-1,0 ZB32-1,6 ZB32-2,4 ZB32-4 ZB32-6 ZB32-10 ZB32-16 ZB32-24 ZB32-32

ZB65-10 ZB65-16 ZB65-24 ZB65-40 ZB65-57 ZB65-63

A Overload relays 0.1 0.16 0.16 0.24 0.24 0.4 0.4 0.6 0.6 1 1 1.6 1.6 2.4 2.4 4 46 69 6 10 9 12 10 16 16 24 24 32 24 40 40 57 57 65

DILEM ZE-0,16 ZE-0,24 ZE-0,4 ZE-0,6 ZE-1,0 ZE-1,6 ZE-2,4 ZE-4 ZE-6 ZE-9

DILM7 DILM12 ZB12-0,16 ZB12-0,24 ZB12-0,4 ZB12-0,6 ZB12-1,0 ZB12-1,6 ZB12-2,4 ZB12-4 ZB12-6 ZB12-10 ZB12-12 ZB12-16

DILM17 DILM32 ZB32-0,16 ZB32-0,24 ZB32-0,4 ZB32-0,6 ZB32-1,0 ZB32-1,6 ZB32-2,4 ZB32-4 ZB32-6 ZB32-10 ZB32-16 ZB32-24 ZB32-32 For use with

DILM40 DILM50 ZB65-10 ZB65-16 ZB65-24 ZB65-40 ZB65-57 ZB65-65 Part number

Free-standing overload relay adaptor Base-mounting bracket ZB32 ZB65 ZB32-XEZ ZB65-XEZ

Enclosed starters

35

Moeller SK0211-1149GB

Moeller's comprehensive range of enclosed starters has been designed to meet the specific needs of the UK market. To satisfy the requirements of most operating environments, they are available in a variety of enclosure sizes and materials: insulated, sheet steel and stainless steel (ideal for the food industry).

Features and benefits IP65 degree of protection for insulated and stainless steel enclosed starters (IP55 for sheet steel enclosed starters), making them suitable for almost every industrial environment. Capable of a high number of operations, the range offers proven reliability plus a long operating life. DOL, reversing DOL and Star Delta versions available as standard All starters are constructed from standard components making them very easy to maintain.
Sheet steel enclosures Part number Stainless steel enclosures Part number

Power rating kW, AC-3, 400 V Compact DOL 4

Overload type

Insulated enclosures Part number

ZE... ZE... ZE...

D4E/I2/3P+N(230V50HZ) D4E/I2/3P+N(400V50HZ) D4E/I2/1P+N(230V50HZ) XDP4/I(230V50HZ) XDP4/I(400V50HZ) XDP5,5/I(230V50HZ) XDP5,5/I(400V50HZ) XDP7,5/I(230V50HZ) XDP7,5/I(400V50HZ) XDP11/I(230V50HZ) XDP11/I(400V50HZ) XDRP4/I(230V50HZ) XDRP4/I(400V50HZ) XDRP5,5/I(230V50HZ) XDRP5,5/I(400V50HZ) XSDP5,5/I/230V50HZ) XSDP5,5/I(400V50HZ) XSDP7,5/I(230V50HZ) XSDP7,5/I(400V50HZ) XSDP11/I(230V50HZ) XSDP11/I(400V50HZ) XSDP15/I(230V50HZ) XSDP15/I(400V50HZ) XDP4/ST(230V50HZ) XDP4/ST(400V50HZ) XDP5,5/ST(230V50HZ) XDP5,5/ST(400V50HZ) XDP7,5/ST(230V50HZ) XDP7,5/ST(400V50HZ) XDP11/ST(230V50HZ) XDP11/ST(400V50HZ) XDRP4/ST(230V50HZ) XDRP4/ST(400V50HZ) XDRP5,5/ST(230V50HZ) XDRP5,5/ST(400V50HZ) XSDP5,5/ST(230V50HZ) XSDP5,5/ST(400V50HZ) XSDP7,5/ST(230V50HZ) XSDP7,5/ST(400V50HZ) XSDP11/ST(230V50HZ) XSDP11/ST(400V50HZ) XSDP15/ST(230V50HZ) XSDP15/ST(400V50HZ) XDP4/SS(230V50HZ) XDP4/SS(400V50HZ) XDP5,5/SS(230V50HZ) XDP5,5/SS(400V50HZ) XDP7,5/SS(230V50HZ) XDP7,5/SS(400V50HZ) XDP11/SS(230V50HZ) XDP11/SS(400V50HZ) XDRP4/SS(230V50HZ) XDRP4/SS(400V50HZ) XDRP5,5/SS(230V50HZ) XDRP5,5/SS(400V50HZ) XSDP5,5/SS(230V50HZ) XSDP5,5/SS(400V50HZ) XSDP7,5/SS(230V50HZ) XSDP7,5/SS(400V50HZ) XSDP11/SS(230V50HZ) XSDP11/SS(400V50HZ) XSDP15/SS(230V50HZ) XSDP15/SS(400V50HZ)

DOL with isolator 4 5.5 7.5 11 DOL reversing with isolator 4 5.5 Star-delta with isolator 5.5 7.5 11 15

ZB12... ZB12... ZB12... ZB12... ZB12... ZB12... ZB32... ZB32... ZB12... ZB12... ZB12... ZB12... ZB12... ZB12... ZB12... ZB12... ZB12... ZB12... ZB32... ZB32...

Enclosed starters

Variable speed drives System overview


Moeller SK0211-1149GB
Radio interference filter

37

Variable speed and vector drives

Remote display unit

POWER

External LCD keypad

ALARM

POWER PRG RUN

Motor choke
RMT READ
COPY

COPY

MNT

PRG

ENTER

FWD REV

Communication module

Braking resistor

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Variable speed drives DF5, DF6

38

Variable speed drives

Moeller SK0211-1149GB

With their innovative modular technology the DF5/6 range combines performance, versatility and economy. Variable speed drives DF5, DF6 These drives offer the latest in functional technology such as automatic voltage monitoring, integral PID control and direct thermistor input, together with the simplicity of an integrated control potentiometer and start/stop buttons. They provide the ideal solution for a wide range of applications, from pumps and fans to conveying and packaging. The drives are supplied with installation diagrams and a CD containing a comprehensive technical manual and Windows based configuration software. Features and benefits Standard items such as conveyor belts, pumps or agitators can be connected and controlled without parameters having to be set. Uniform terminal designations and accessories across the range reduce engineering requirements. Windows based PC software simplifies commissioning.

Rated power of motor kW Variable speed drives DF5, DF6 Single-phase input AC drives, 230 V 0.18 0.37 0.55 0.75 1.1 1.5 2.2

Part number

DF5-322-018 DF5-322-037 DF5-322-055 DF5-322-075 DF5-322-1K1 DF5-322-1K5 DF5-322-2K2

Three-phase AC drives, 400 V 0.37 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 DF5-340-037 DF5-340-075 DF5-340-1K5 DF5-340-2K2 DF5-340-3K0 DF5-340-4K0 DF5-340-5K5 DF5-340-7K5 DF6-340-11K DF6-340-15K DF6-340-18K5 DF6-340-22K

Filters, accessories

39

Moeller SK0211-1149GB For use with AC drives DF5 Rated power of motor kW EMC filters to EN 5081-1, footprint-fitting Single-phase 0.18 0.55 1.1 Three-phase 0.37 2.2 5.5 11 18.5 0.75/1.5 3/4 7.5 15 22 DE5-LZ3-007-V4 DE5-LZ3-011-V4 DE5-LZ3-020-V4 DE6-LZ3-032-V4 DE6-LZ3-064-V4 0.37 0.75 1.5/2.2 DE5-LZ1-007-V2 DE5-LZ1-012-V2 DE5-LZ1-024-V2 Part number DF6 Rated power of motor kW

Accessories PROFIBUS interface DE5-NET-DP Remote display unit 1 metre cable for display unit 2 metre cable for PC connection DE5-KEY-R03 DE5-CBL-1M0-ICL DEX-CBL-2M0-PC

Variable speed drives DF5, DF6

40
Semiconductor contactors, soft starters DS4

Semiconductor contactors, soft starters

Moeller SK0211-1149GB

The DS4 range comprises semiconductor contactors for high switching frequencies and soft starters for applications with normal starting frequencies. Combining compactness with versatility, the range offers condition signalling, a wide variety of voltage inputs in one unit as well as compliance with the latest international safety standards. The single phase versions are designed for resistive loads such as heating and lighting, whilst the three phase versions are suitable for both resistive and inductive loads, including motors. Features and benefits Semiconductor contactors offer silent switching ideal for office environments. wear-free switching, suitable for high frequency switching in temperature critical processes, packaging machines and other high speed applications. Soft starters reduce the starting current, so minimising power costs and avoiding torque shocks in motors. can reduce mechanical stress on shafts, bearings and belts, so extending service intervals and reducing breakages.

AC-51 current rating A Single-phase semiconductor contactors 10 20 30 50

AC-3 motor rating at 400 V kW

Part number

DS4-140-010-H DS4-140-020-H DS4-140-030-H DS4-140-050-H

Three-phase semiconductor contactors and soft starters Without bypass 11 17 22 29 41 2.2 4 5.5 7.5 11 DS4-340-2K2-M DS4-340-4K0-M DS4-340-5K5-M DS4-340-7K5-M DS4-340-11K-M

Semiconductor contactors, soft starters

41
Semiconductor contactors, soft starters DS4

Moeller SK0211-1149GB AC-53 current rating A Three-phase semiconductor contactors and soft starters Reversing, without bypass 6 9 12 16 23 2.2 4 5.5 7.5 11 DS4-340-2K2-MR DS4-340-4K0-MR DS4-340-5K5-MR DS4-340-7K5-MR DS4-340-11K-MR AC-3 motor rating at 400 V kW Part number

Three-phase soft starters With bypass 16 23 31 7.5 11 15 DS4-340-7K5-MX DS4-340-11K-MX DS4-340-15K-MX

Reversing, with bypass 16 23 31 7.5 11 15 DS4-340-7K5-MXR DS4-340-11K-MXR DS4-340-15K-MXR

42

Insulated enclosures

Moeller SK0211-1149GB

Insulated enclosures CI-K

Suitable for housing a wide range of protection and control devices, the robust CI-K enclosures are rated to IP65 degree of protection. Metric cable entry knockouts in the top, bottom and rear of the enclosure make installation easy. A choice of the unique push-through membrane or hard knockout versions provide added flexibility. The units are ideal for housing Moeller products including: T rotary switches, P switch-disconnectors, RMQ-Titan command and signalling devices, xStart contactors, FAZ miniature circuit-breakers, easy control relays, ETR4 timing relays, and PKZ motor-protective circuit-breakers. They also make excellent terminal boxes and can be used to house pneumatic or hydraulic components. Features and benefits Fully insulated with no need to earth, resistant to flaking or rusting which is particularly important for the food industry. Choice of mounting rails and plates, with fixing holes for vertical or horizontal positioning, simplifies mounting. Captive screws, fixing centres printed on the base, rubber feet to compensate for wall unevenness and optional external fixing brackets all simplify installation. Shallow base depth eases connection to devices mounted in the enclosure. Eyelets on the base and cover mean tie wraps can be used as a simple hinge when accessing the contents of the enclosure.

Width mm Insulated enclosures, IP65 Fitted with DIN mounting rail 80 100

Height mm

Depth mm

Metric cable entry

Part number

120 160

95 100 145

Push-through membrane Push-through membrane Hard knockouts Push-through membrane Hard knockouts Hard knockouts Hard knockouts Hard knockouts Hard knockouts Hard knockouts Push-through membrane Hard knockouts Push-through membrane Hard knockouts Hard knockouts Hard knockouts Hard knockouts Hard knockouts Hard knockouts

CI-K1-95-TS CI-K2-100-TS CI-K2H-100-TS CI-K2-145-TS CI-K2H-145-TS CI-K3-125-TS CI-K3-160-TS CI-K4-125-TS CI-K4-160-TS CI-K5-125-TS CI-K2-100-M CI-K2H-100-M CI-K2-145-M CI-K2H-145-M CI-K3-125-M CI-K3-160-M CI-K4-125-M CI-K4-160-M CI-K5-125-M

120 160 200 Fitted with metal mounting plate 100

200 240 280 160

125 160 125 160 125 100 145

120 160 200

200 240 280

125 160 125 160 125

Switch-disconnectors, rotary switches System overview


Moeller SK0211-1149GB

43

Isolators: T0, T3, T5B, T5


Service distribution board mounting Rear mounting

Door mounting Coupling drive Surface mounting

Thumb-grip with front plate Safety switch

Thumb-grip, for use as Emergency-Stop device

Main switch (assembly kit) Main switch (assembly kit), for use as Emergency-Stop device

Control switches: T0, T3, T5B, T5


Service distribution board mounting

Rear mounting

Door mounting Coupling drive Surface mounting

Thumb-grip with front plate

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Switch-disconnectors, rotary switches P, T

44

Switch-disconnectors

Switch-disconnectors, rotary switches P, T

Moeller SK0211-1149GB

The reliable and robust T&P isolators are quick and easy to install and, together with simple selection, offer savings in both time and cost. Current ratings are from 20 A to 100 A with power ratings from 4 kW to 37 kW. They are suitable for main, maintenance and Emergency-Stop switches, being available in their own enclosures or for mounting in control cabinets, either on the door or rear of the panel with cover interlock. The T0 range of control switches is suitable for many different switching and control functions, such as ON/OFF, Hand/Auto and changeover. Manufactured in the UK, this highly flexible system satisfies a wide range of applications, and can be customised to suit specific needs. Features and benefits Isolators All switches to IEC/EN 60204 & IEC/EN 60947. Padlockable in the OFF position (using up to three padlocks) for safe, secure maintenance. Available in insulated, sheet steel or stainless steel enclosures to meet all applications. With a high protection standard of IP65, they can be used in most environments including the food industry. Control switches Sharing the same design criteria as the RMQ-Titan range, T0 switches can be combined with this system to offer even greater functionality. A broad range of mounting and fitting options speeds assembly and meets every operational requirement.

Switch application ratings Three-phase motor ratings Rated operational current AC-23 AC-3 AC-21 AC-15 380 440 V 380 440 V 380 440 V 3~ 220 240 V 380 415 V kW kW A A A A

Rated uninterrupted current (Iu)

Switch size T0 T3 6.5 13 4 12 20 32 6 10 4 6 20 32

T5B 22 22 63 16 6 63

T5 30 30 100 16 6 100

P1 13 7.5 25 25

15 13 32 32

P3 37 30 63 63

50 37 100 100

No. of poles

Rated uninterrupted current (Iu) A

Part number

Isolators, IP65 Insulated, enclosed isolators With metric knockouts, padlockable handle 1 20 32 63 100 20 32 63 100 20 25 32 63 100 20 32 63 100 T0-1-8200/I1/SVB T3-1-8200/I2/SVB T5B-1-8200/I4/SVB T5-1-8200/I5/SVB T0-1-102/I1/SVB T3-1-102/I2/SVB T5B-1-102/I4/SVB T5-1-102/I5/SVB T0-2-1/I1/SVB P1-25/I2H/SVB P1-32/I2H/SVB P3-63/I4/SVB P3-100/I5/SVB T0-3-8342/I1/SVB T3-3-8342/I2/SVB T5B-3-8342/I4/SVB T5-3-8342/I5/SVB

Switch-disconnectors, accessories

45

No. of poles

Rated uninterrupted current (Iu) A

Part number

Stainless steel, enclosed isolators 3 20 25 32 63 100 T0-2-1/SS1/SVB P1-25/SS1/SVB P1-32/SS1/SVB P3-63/SS2/SVB P3-100/SS2/SVB

Sheet steel, enclosed isolators 3 20 25 32 63 85 T0-2-1/ST1/SVB P1-25/ST1/SVB P1-32/ST1/SVB P3-63/ST2/SVB P3-100/ST2/SVB

Rear mount, door interlock, padlockable handle 2 20 32 63 100 20 25 32 63 100 20 32 63 100 20 25 32 63 100 T0-1-102/V/SVB T3-1-102/V/SVB T5B-1-102/V/SVB T5-1-102/V/SVB T0-2-1/V/SVB P1-25/V/SVB P1-32/V/SVB P3-63/V/SVB P3-100/V/SVB T0-1-102/EA/SVB T3-1-102/EA/SVB T5B-1-102/EA/SVB T5-1-102/EA/SVB T0-2-1/EA/SVB P1-25/EA/SVB P1-32/EA/SVB P3-63/EA/SVB P3-100/EA/SVB

Door mount, padlockable handle 2

For use with Accessories Switched neutral poles Door mounting P1 isolators Rear mounting and enclosed P1 isolators Door mounting P3 isolators Rear mounting and enclosed P3 isolators Auxiliary contacts 1 N/O 1 N/C, for door mounting P1/3 isolators 1 N/O 1 N/C, for rear mounting and enclosed P1/3 isolators Plug-in shaft extensions T0 and P1 switches P3 switches Plug-in interlock extensions T0 and P1 switches P3 switches

Part number

N-P1E N-P1Z N-P3E N-P3Z

HI11-P1/P3E HI11-P1/P3Z ZAV-T0 ZAV-P3 ZVV-T0 ZVV-P3

Switch-disconnectors, rotary switches P, T

Moeller SK0211-1149GB

46

Rotary switches

Switch-disconnectors, rotary switches P, T

Moeller SK0211-1149GB No. of poles Description Part number

Control switches, door mounting, IP65 20 A rated uninterrupted current (Iu) With black thumb grip and front plate On-Off

1 2 3

90 switching

T0-1-8200/E T0-1-102/E T0-2-1/E

Changeover with Off

1 2 3

60 switching with centre Off

T0-1-8210/E T0-2-8211/E T0-3-8212/E

Changeover without Off

1 2 3

60 switching 90 switching

T0-1-8220/E T0-2-8221/E T0-3-8222/E

Hand-Auto

1 2 3

90 switching

T0-1-15451/E T0-2-15452/E T0-3-15453/E

Hand-Off-Auto

1 2 3

45 switching with centre Off

T0-1-15431/E T0-2-15432/E T0-3-15433/E

Ammeter switch

90 switching with complete rotation in both directions

T0-3-8048/E

Voltmeter switch

3 x phase-to-phase, 3 x phase-to-N, with Off position

T0-3-8007/E

Motor-protective circuit-breakers System overview


Moeller SK0211-1149GB

47

PKZM01 pushbutton motor-protective circuit-breaker up to 16 A

Voltage trip

PKZM0 motor-protective circuit-breaker up to 32 A

Side mounting auxiliary contacts Door coupling rotary handle IP65

Front fitting auxiliary contact

PKZM4 motor-protective circuit-breaker up to 65 A Current limiter

Clip plate

PKZM0 motor-protective circuit-breaker

Compact starter

High-capacity compact starter

Standard auxiliary contact

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4

48

Motor-protective circuit-breakers

Moeller SK0211-1149GB

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4 Part of the xStart motor protection range (see page 29), PKZ has become a global brand for motor-protective circuit-breakers providing isolation, short-circuit protection and thermal protection in one single component. The range includes both rotary and pushbutton actuated motor-protective circuit-breakers. The rotary handle gives a clear and immediate indication of ON/OFF positions even from a distance, complying as a switch-disconnector in accordance with IEC 947-2/3 and IEC 204-1. The lockable rotary handle and door coupling handle options enable the motor-protective circuit-breakers to be locked in the OFF position for extra safety.

The pushbutton actuation is suited to small machines and applications where pressing or even hitting a button is preferred. A mushroom head is available for installations requiring an Emergency-Stop function. Features and benefits Single range of clip-on accessories across all types makes selection easy and reduces fitting times. With just two rotary handle variants engineering is simplified. Compact width saves valuable space in the control panel. Insulated enclosures enable use in harsh environments.
PKZM4 (Rotary handle type) 10 65 A Rated operational current Ie A 0.21 0.31 0.41 0.6 0.8 1.1 1.5 1.9 2.6 3.6 5 6.6 8.5 11.3 15.2 18.2 21.7 25 29.3 Motor rating P kW Rated operational current Ie A

Range overview Setting range of overload trip Ir Motor data 400 V

PKZM01 (Pushbutton type) 0.1 16 A Motor rating P kW 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 Rated operational current Ie A 0.21 0.31 0.41 0.6 0.8 1.1 1.5 1.9 2.6 3.6 5 6.6 8.5 11.3 15.2

PKZM0 (Rotary handle type, for use with toolless plug connector) 0.1 32 A Motor rating P kW 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9 11 12.5 15

5.5 7.5 9 11 12.5 15 18.5 20 22 30 34

11.3 15.2 18.2 21.7 25 29.3 36 40 41 55 65

Motor-protective circuit-breakers

49

Moeller SK0211-1149GB Overload range A Pushbutton type PKZM01 0.1 0.16 0.16 0.25 0.25 0.4 0.4 0.63 0.63 1 1 1.6 1.6 2.5 2.5 4 4 6.3 6.3 10 8 12 10 16 Accessories for PKZM01 (also see page 50) Insulated enclosures Surface mounting IP40 IP65 IP65 padlockable in Off position IP65 with stay-put Emergency-Stop IP65 with stay-put Emergency-Stop (key release) CI-PKZ01 CI-PKZ01-G CI-PKZ01-SVB CI-PKZ01-PVT CI-PKZ01-PVS PKZM01-0,16 PKZM01-0,25 PKZM01-0,4 PKZM01-0,63 PKZM01-1 PKZM01-1,6 PKZM01-2,5 PKZM01-4 PKZM01-6,3 PKZM01-10 PKZM01-12 PKZM01-16 Description Part number

Flush mounting IP40 IP55 IP55 padlockable in Off position IP55 with stay-put Emergency-Stop IP55 with stay-put Emergency-Stop (key release) E-PKZ01 E-PKZ01-G E-PKZ01-SVB E-PKZ01-PVT E-PKZ01-PVS

Rotary handle type PKZM0 0.1 0.16 0.16 0.25 0.25 0.4 0.4 0.63 0.63 1 1 1.6 1.6 2.5 2.5 4 4 6.3 6.3 10 8 12 10 16 16 20 20 25 25 32 PKZM0-0,16 PKZM0-0,25 PKZM0-0,4 PKZM0-0,63 PKZM0-1 PKZM0-1,6 PKZM0-2,5 PKZM0-4 PKZM0-6,3 PKZM0-10 PKZM0-12 PKZM0-16 PKZM0-20 PKZM0-25 PKZM0-32

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4

50

Motor-protective circuit-breakers

Moeller SK0211-1149GB

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4

Overload range A Rotary handle type PKZM4 10 16 16 25 25 32 32 40 40 50 50 58 55 65

Description

Part number

PKZM4-16 PKZM4-25 PKZM4-32 PKZM4-40 PKZM4-50 PKZM4-58 PKZM4-63

Accessories for PKZM01, PKZM0 and PKZM4 Auxiliary contacts 1 N/O 1 N/C , side mounting 1 N/O 2 N/C , side mounting 2 N/O 1 N/C , side mounting 1 N/O 1 N/C, front fitting 1 N/O, front fitting NHI11-PKZ0 NHI12-PKZ0 NHI21-PKZ0 NHI-E-11-PKZ0 NHI-E-10-PKZ0

Shunt trips 230 V AC 24 V DC A-PKZ0(230V 50HZ) A-PKZ0(24VDC)

Undervoltage trips 110 V AC 230 V AC 240 V AC 24 V AC 400 V AC U-PKZ0(110V50HZ) U-PKZ0(230V50HZ) U-PKZ0(240V50HZ) U-PKZ0(24V50HZ) U-PKZ0(400V50HZ)

Accessories for PKZM0 and PKZM4 Early-make auxiliary contacts VHI20-PKZ0

Trip-indicating auxiliary contacts 2 N/C 2 N/O AGM2-01-PKZ0 AGM2-10-PKZ0

Motor-protective circuit-breakers

51

Moeller SK0211-1149GB Description Part number

Handles Door coupling rotary handle (red/yellow) Door coupling rotary handle (black) RH-PKZ0 H-PKZ0

Direct mounting, padlockable rotary handle

AK-PKZ0

Accessories for PKZM0 only Insulated enclosures Surface mounting IP40 for vertical mounting IP55 with black/grey handle IP55 with red/yellow handle CI-PKZ0-M CI-PKZ0-GM CI-PKZ0-GRM

System for direct connection between PKZM0 and DILM contactors DOL toolless plug connection PKZM0 + DILM7/9/12

PKZM0-XDM12

DOL starter connection kit Reversing toolless plug connection

PKZM0 + DILM17/25/32 PKZM0 + DILM7/9/12-01

PKZM0-XDM32 PKZM0-XRM12

Reversing starter connection kit Current limiter

PKZM0 + DILM17/25/32 For increasing switching capacity to 150 kA

PKZM0-XRM32 CL-PKZ0

Motor-protective circuit-breakers PKZM01, PKZM0, PKZM4

Miniature circuit-breakers System overview


Moeller SK0211-1149GB

53

Xpole (5 - 15 kA) miniature circuit-breakers


XU A

Range of installation devices

Voltage trip
FA Z

FA

Z-2

XA XA A A

FA

Z-3

Remote switching module


FA

FA Z

Z-3

-2

Auxiliary contact
XF SM

FA Z

-4

Add-on residual current device modules

XR

HI

00

Auxiliary contact

FIL

Combined RCD/MCB devices (RCBO)


S

Residual current devices


XP

M0

Voltage trip

FIP

-2

Auxiliary contact
FIP
AZ XA

-4

Remote switching module


XR HI00 2

AZ

Add-on residual current device module

AZ

-2

XF

SM

AZ

-3

Auxiliary contact
AZ -3N

AZ

FIM -4-1

25

-0,3

AZ (15 - 25 kA) miniature circuit-breakers

AZ XH

I11

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Miniature circuit-breakers

Voltage trip

54

Industrial miniature circuit-breakers

Moeller SK0211-1149GB

The comprehensive range of Xpole miniature circuit-breakers includes 10 and 15 kA switching capacity in single-pole and multi-pole versions. The range offers the following tripping characteristics: Type B for domestic/commercial installations without power surges e.g. filament lamps and wall sockets Type C for commercial/light industrial installations with switching surges such as fluorescent lighting or small motors Type D for abnormally high inrush currents e.g. motors with heavy starting duty Type K to prevent nuisance tripping during starting of three phase loads e.g. motors or transformers, and provide closer protection than B, C or D types Type S for the protection of control circuits with high inrush currents and transformers In addition, the range includes components for residual current protection and modular installation devices for remote switching, timing and signalling. Features and benefits FAZ range offers worldwide approvals and shipping classification. DIN rail clip mounting, and snap-fitting accessories reduce installation time and simplify fitting and removal of components. Single design concept improves panel appearance. Busbar clamps and high-capacity box terminals provide increased connection options.

Miniature circuit-breakers
Rated current In A 15 kA, Type B 3 5 x In response current of short circuit trip 4 6 10 12 16 20 25 32 40 50 63 FAZ-B4/1-HS FAZ-B6/1 FAZ-B10/1 FAZ-B12/1 FAZ-B16/1 FAZ-B20/1 FAZ-B25/1 FAZ-B32/1 FAZ-B40/1 FAZ-B50/1 FAZ-B63/1

Single pole Part number

Double pole Part number

Triple pole Part number

FAZ-B4/2-HS FAZ-B6/2 FAZ-B10/2 FAZ-B12/2 FAZ-B16/2 FAZ-B20/2 FAZ-B25/2 FAZ-B32/2 FAZ-B40/2 FAZ-B50/2 FAZ-B63/2

FAZ-B6/3 FAZ-B10/3 FAZ-B12/3 FAZ-B16/3 FAZ-B20/3 FAZ-B25/3 FAZ-B32/3 FAZ-B40/3 FAZ-B50/3 FAZ-B63/3

Industrial miniature circuit-breakers

55

Moeller SK0211-1149GB Rated current In A 15 kA, Type C 5 10 x In response current of short circuit trip 0.5 1 2 4 6 10 16 20 25 32 40 50 63 15 kA, Type D 10 20 x In response current of short circuit trip 0.5 1 2 4 6 10 16 20 25 32 40 15 kA, Type K 8 12 x In response current of short circuit trip 0.5 1 2 4 6 10 16 20 25 32 40 50 63 10 kA, Type S 13 17 x In response current of short circuit trip 1 2 3 4 6 10 16 20 25 32 40 FAZ-S1/1 FAZ-S2/1 FAZ-S3/1 FAZ-S4/1 FAZ-S6/1 FAZ-S10/1 FAZ-S16/1 FAZ-S20/1 FAZ-S25/1 FAZ-S32/1 FAZ-S40/1 FAZ-S1/2 FAZ-S2/2 FAZ-S3/2 FAZ-S4/2 FAZ-S6/2 FAZ-S10/2 FAZ-S16/2 FAZ-S20/2 FAZ-S25/2 FAZ-S32/2 FAZ-S40/2 FAZ-K0,5/1 FAZ-K1/1 FAZ-K2/1 FAZ-K4/1 FAZ-K6/1 FAZ-K10/1 FAZ-K16/1 FAZ-K20/1 FAZ-K25/1 FAZ-K32/1 FAZ-K40/1 FAZ-K50/1 FAZ-K63/1 FAZ-K0,5/2 FAZ-K1/2 FAZ-K2/2 FAZ-K4/2 FAZ-K6/2 FAZ-K10/2 FAZ-K16/2 FAZ-K20/2 FAZ-K25/2 FAZ-K32/2 FAZ-K40/2 FAZ-K50/2 FAZ-K63/2 FAZ-K0,5/3 FAZ-K1/3 FAZ-K2/3 FAZ-K4/3 FAZ-K6/3 FAZ-K10/3 FAZ-K16/3 FAZ-K20/3 FAZ-K25/3 FAZ-K32/3 FAZ-K40/3 FAZ-K50/3 FAZ-K63/3 FAZ-D0,5/1 FAZ-D1/1 FAZ-D2/1 FAZ-D4/1 FAZ-D6/1 FAZ-D10/1 FAZ-D16/1 FAZ-D20/1 FAZ-D25/1 FAZ-D32/1 FAZ-D40/1 FAZ-D0,5/2 FAZ-D1/2 FAZ-D2/2 FAZ-D4/2 FAZ-D6/2 FAZ-D10/2 FAZ-D16/2 FAZ-D20/2 FAZ-D25/2 FAZ-D32/2 FAZ-D40/2 FAZ-D0,5/3 FAZ-D1/3 FAZ-D2/3 FAZ-D4/3 FAZ-D6/3 FAZ-D10/3 FAZ-D16/3 FAZ-D20/3 FAZ-D25/3 FAZ-D32/3 FAZ-D40/3 FAZ-C0,5/1 FAZ-C1/1 FAZ-C2/1 FAZ-C4/1 FAZ-C6/1 FAZ-C10/1 FAZ-C16/1 FAZ-C20/1 FAZ-C25/1 FAZ-C32/1 FAZ-C40/1 FAZ-C50/1 FAZ-C63/1 FAZ-C0,5/2 FAZ-C1/2 FAZ-C2/2 FAZ-C4/2 FAZ-C6/2 FAZ-C10/2 FAZ-C16/2 FAZ-C20/2 FAZ-C25/2 FAZ-C32/2 FAZ-C40/2 FAZ-C50/2 FAZ-C63/2 FAZ-C0,5/3 FAZ-C1/3 FAZ-C2/3 FAZ-C4/3 FAZ-C6/3 FAZ-C10/3 FAZ-C16/3 FAZ-C20/3 FAZ-C25/3 FAZ-C32/3 FAZ-C40/3 FAZ-C50/3 FAZ-C63/3 Single pole Part number Double pole Part number Triple pole Part number

Miniature circuit-breakers

56

Distribution miniature circuit-breakers

Moeller SK0211-1149GB Rated current In A 10 kA, Type B 3 5 x In response current of short circuit trip 6 10 16 20 25 32 40 50 63 10 kA, Type C 5 10 x In response current of short circuit trip 6 10 16 20 25 32 40 50 63 10 kA, Type D 10 20 x In response current of short circuit trip 6 10 16 20 25 32 40 Notes PLSM-D6 PLSM-D10 PLSM-D16 PLSM-D20 PLSM-D25 PLSM-D32 PLSM-D40 PLSM-D6/2 PLSM-D10/2 PLSM-D16/2 PLSM-D20/2 PLSM-D25/2 PLSM-D32/2 PLSM-D40/2 PLSM-D6/3 PLSM-D10/3 PLSM-D16/3 PLSM-D20/3 PLSM-D25/3 PLSM-D32/3 PLSM-D40/3 PLSM-C6 PLSM-C10 PLSM-C16 PLSM-C20 PLSM-C25 PLSM-C32 PLSM-C40 PLSM-C50 PLSM-C63 PLSM-C6/2 PLSM-C10/2 PLSM-C16/2 PLSM-C20/2 PLSM-C25/2 PLSM-C32/2 PLSM-C40/2 PLSM-C50/2 PLSM-C63/2 PLSM-C6/3 PLSM-C10/3 PLSM-C16/3 PLSM-C20/3 PLSM-C25/3 PLSM-C32/3 PLSM-C40/3 PLSM-C50/3 PLSM-C63/3 PLSM-B6 PLSM-B10 PLSM-B16 PLSM-B20 PLSM-B25 PLSM-B32 PLSM-B40 PLSM-B50 PLSM-B63 PLSM-B6/2 PLSM-B10/2 PLSM-B16/2 PLSM-B20/2 PLSM-B25/2 PLSM-B32/2 PLSM-B40/2 PLSM-B50/2 PLSM-B63/2 PLSM-B6/3 PLSM-B10/3 PLSM-B16/3 PLSM-B20/3 PLSM-B25/3 PLSM-B32/3 PLSM-B40/3 PLSM-B50/3 PLSM-B63/3 Single pole Part number Double pole Part number Triple pole Part number

Miniature circuit-breakers

PLSM circuit-breakers have colour-coded toggle switches, as follows:

2A

4A

6A

10 A 13 A 16 A

20 A 25 A 32 A 40 A 50 A 63 A

Installation devices RCD, RCBO, modular contactors, time switches


Moeller SK0211-1149GB Rated uninterrupted current Iu A Standard AC residual current devices 25 25 40 40 63 63 63 80 80 80 Rated current In A Combined RCD/MCB devices (RCBO), single-phase and neutral 2 4 6 10 13 16 32 40 30 100 30 100 30 100 300 30 100 300 Tripping current mA PFIM-25/2/003 PFIM-25/2/01 PFIM-40/2/003 PFIM-40/2/01 PFIM-63/2/003 PFIM-63/2/01 PFIM-63/2/03 PFIM-80/2/003 PFIM-80/2/01 PFIM-80/2/03 Type B 3 5 x In PFIM-25/4/003 PFIM-25/4/01 PFIM-40/4/003 PFIM-40/4/01 PFIM-63/4/003 PFIM-63/4/01 PFIM-63/4/03 PFIM-80/4/003 PFIM-80/4/01 PFIM-80/4/03 Type C 5 10 x In PKNM-2/1N/C/003 PKNM-4/1N/C/003 PKNM-6/1N/C/003 PKNM-10/1N/C/003 PKNM-13/1N/C/003 PKNM-16/1N/C/003 PKNM-32/1N/C/003 PKNM-40/1N/C/003 Tripping current mA 2-pole 4-pole

57

30 PKNM-6/1N/B/003 PKNM-10/1N/B/003 PKNM-16/1N/B/003 PKNM-32/1N/B/003 PKNM-40/1N/B/003

Rated current In A Modular contactors 25 25 25 25 40 40 40 40 63 63 63 63 25 25 Programme A Time switches, analog Day Day Week Week Day Day & week

Contacts

Actuating voltage

Part number

4 N/O 2 N/O 2 N/C 3 N/O 1 N/C 4 N/C 2 N/O 4 N/O 2 N/O 2 N/C 3 N/O 1 N/C 2 N/O 4 N/O 2 N/O 2 N/C 3 N/O 1 N/C 4 N/O 2 N/O 2 N/C Contacts

230 V AC, 50 Hz coil

Z-SCH230/25-40 Z-SCH230/25-22 Z-SCH230/25-31 Z-SCH230/25-04 Z-SCH230/40-20 Z-SCH230/40-40 Z-SCH230/40-22 Z-SCH230/40-31 Z-SCH230/63-20 Z-SCH230/63-40 Z-SCH230/63-22 Z-SCH230/63-31 Z-SCH24/25-40 Z-SCH24/25-22 Part number

24 V AC, 50 Hz coil

Drive

1 N/O 1 C/O 1 C/O 1 C/O 1 C/O 2 C/O

Quartz Quartz Quartz Synchronous Synchronous Quartz

SU-GQ-TA SU-GQ/1W-TA SU-GQ/1W-WO SU-GS/1W-WO SU-GS/1W-TA SU-GQ/2W-TW

Miniature circuit-breakers

58

Miniature circuit-breakers, accessories

Moeller SK0211-1149GB Poles Rated operational current Ie A No. of 17.5 mm modules Part number

Miniature circuit-breakers

Commoning busbars with fork connectors, closed end 1 1 1 2 2 2 3 3 Busbar combs with fork connectors, open end 1 m length 1 1 3 3 Busbar end caps For use with Z-GV-10... For use with Z-GV-16... Busbar tag shrouds

85 85 85 100 100 100 100 100

2 6 12 4 6 12 6 12

FAZ-XIS1/2 FAZ-XIS1/6 FAZ-XIS1/12 FAZ-XIS2/4 FAZ-XIS2/6 FAZ-XIS2/12 FAZ-XIS3/6 FAZ-XIS3/12

63 80 63 80

57 57 57 57

Z-GV-10/1P-1TE Z-GV-16/1P-1TE Z-GV-10/3P-3TE Z-GV-16/3P-3TE Z-AK-10/2+3P Z-AK-16/2+3P FAZ-XB5

Contacts

For use with

Part number

Accessories Shunt trips All miniature circuit-breakers FAZ-XAA-C-12-110VAC FAZ-XAA-C-110-415VAC

Auxiliary contact, AC-11, 6 A at 230 V 1 N/O 1 N/C All miniature circuit-breakers FAZ-XHI11

Trip-indicating auxiliary contact, AC-11, 6 A at 230 V 2 x C/O All miniature circuit-breakers FAZ-XAM002

Sealing covers Two 17.5 mm units Three 17.5 mm units Modular contactors Z-SCHAK-2TE Z-SCHAK-3TE

Moulded case circuit-breakers, switch-disconnectors System overview


Moeller SK0211-1149GB

59

Tunnel terminals Control circuit terminal

Delay unit for undervoltage tripping

Terminal cover

Plug-in and withdrawable unit IPX2 protection against contact with a finger Early-make auxiliary contact/voltage trip Moulded case circuit-breaker Data management interface EASY-LINK-DS data plug Rear connection Clip plate

PROFIBUS-DP interface Side operator handle

Mounting spacer

Standard auxiliary contact/ trip-indicating auxiliary contact

Toggle lever interlock device

Remote operator Rotary handle Door coupling rotary handle External warning plate/ designation Extension shaft Main switch rotary handle for side panel mounting

Insulating surround

Door coupling rotary handle

For our complete range, and technical details, see our main catalogue or visit www.moeller.co.uk

Moulded case circuit-breakers NZM switch-disconnectors PN, N

60

Moulded case circuit-breakers

Moeller SK0211-1149GB

Moulded case circuit-breakers NZM switch-disconnectors PN, N

Moeller's NZM1, 2, 3 & 4 moulded case circuit-breakers and PN & N main switches have a uniquely uniform approach to mounting, operation and switching, with accessories saving time and money. Available in four frame sizes, with toggle or rotary handle options, the NZM1 4 are suitable for a wide variety of applications. Contacts from the RMQ-Titan range of control circuit devices simply clip in from the front of the circuit-breakers to provide remote status indication. The optional data management interface for the breakers with electronic trips improves diagnostics and allows rapid fault analysis, so minimising downtime. Features and benefits Common base plate on all rotary handles for simplified engineering Compact size saves panel space. Choice of toggle actuator or rotary handle offers adaptability. Identical operation, function, mounting and fitting for every frame size with standard mounting spacers for user-friendly installation. Uniform range of auxiliary contacts and releases with simple screw or spring-loaded connections speeds assembly and reduces inventory costs. Innovative double-break contact system (on sizes 2 and 3) offers enhanced breaking capacity.

Rated uninterrupted current A Thermomagnetic trip for system/cable protection, 3-pole 40 50 63 80 100 125 125 160 200 250

Setting range of overload trip A

Part number 25 kA

Part number 50 kA

32 40 40 50 50 63 63 80 80 100 100 125 100 125 125 160 160 200 200 250

NZMB1-A40 NZMB1-A50 NZMB1-A63 NZMB1-A80 NZMB1-A100 NZMB1-A125 NZMB2-A125 NZMB2-A160 NZMB2-A200 NZMB2-A250

NZMN1-A40 NZMN1-A50 NZMN1-A63 NZMN1-A80 NZMN1-A100 NZMN1-A125 NZMN2-A125 NZMN2-A160 NZMN2-A200 NZMN2-A250

Moulded case circuit-breakers, switch-disconnectors

61

Moeller SK0211-1149GB Rated uninterrupted current A Electronic trip for system, cable & generator protection, 3-pole, 50 kA 100 160 250 Setting range of overload trip A Part number

50 100 80 160 125 250

NZMN2-VE100 NZMN2-VE160 NZMN2-VE250

250 400 630

125 250 200 400 315 630

NZMN3-VE250 NZMN3-VE400 NZMN3-VE630

630 800 1000 1250 1600

315 630 400 800 500 1000 630 1250 800 1600

NZMN4-VE630 NZMN4-VE800 NZMN4-VE1000 NZMN4-VE1250 NZMN4-VE1600

Main switch for manual operation, 3-pole 63 100 125 PN1-63 PN1-100 PN1-125

160 200 250

PN2-160 PN2-200 PN2-250

Main switch for manual operation, 3-pole Remote actuation possible 63 100 125 N1-63 N1-100 N1-125

160 200 250

N2-160 N2-200 N2-250

Moulded case circuit-breakers NZM switch-disconnectors PN, N

62

Moulded case circuit-breakers, switch-disconnectors Accessories


Moeller SK0211-1149GB

Moulded case circuit-breakers NZM switch-disconnectors PN, N

Description

For use with

Part number

Auxiliary Contacts Internal fixing, N/O contact Internal fixing, N/C contact 2 x early-make contacts 2 x early-make contacts 2 x early-make contacts NZM..., PN..., N... NZM..., PN..., N... NZM1, PN1, N1 NZM2, NZM3, PN2, N2 NZM4 M22-K10 M22-K01 NZM1-XHIV NZM2/3-XHIV NZM4-XHIV

Shunt trips 24 V AC/DC 110 130 V AC/DC 208 250 V AC/DC 380 V 440 V AC/DC 24 V AC/DC 110 130 V AC/DC 208 250 V AC/DC 380 V 440 V AC/DC NZM1, N1 NZM1-XA24AC/DC NZM1-XA110-130AC/DC NZM1-XA208-250AC/DC NZM1-XA380-440AC/DC NZM2/3-XA24AC/DC NZM2/3-XA110-130AC/DC NZM2/3-XA208-250AC/DC NZM2/3-XA380-440AC/DC

NZM2, NZM3, N2

24 V AC/DC 110 130 V AC/DC 208 250 V AC/DC 380 V 440 V AC/DC Under voltage trips 24 V AC 110 130 V AC 208 240 V AC 380 V 440 V AC 24 V AC 110 130 V AC 208 240 V AC 380 V 440 V AC

NZM4

NZM4-XA24AC/DC NZM4-XA110-130AC/DC NZM4-XA208-250AC/DC NZM4-XA380-440AC/DC

NZM1, N1

NZM1-XU24AC NZM1-XU110-130AC NZM1-XU208-240AC NZM1-XU380-440AC NZM2/3-XU24AC NZM2/3-XU110-130AC NZM2/3-XU208-240AC NZM2/3-XU380-440AC

NZM2, NZM3, N2

24 V AC 110 130 V AC 208 240 V AC 380 V 440 V AC Handles Rotary handle/drive Black, direct mounting on NZM..., padlockable

NZM4

NZM4-XU24AC NZM4-XU110-130AC NZM4-XU208-240AC NZM4-XU380-440AC

NZM1, PN1, N1 NZM2, PN2, N2 NZM3 NZM4 NZM1, PN1, N1 NZM2, PN2, N2 NZM3 NZM4 NZM1, PN1, N1 NZM2, PN2, N2 NZM3 NZM4

NZM1-XDV NZM2-XDV NZM3-XDV NZM4-XDV NZM1-XTVDV NZM2-XTVDV NZM3-XTVDV NZM4-XTVDV NZM1-XTVDVR NZM2-XTVDVR NZM3-XTVDVR NZM4-XTVDVR

Door coupling handle/drive Black/grey, padlockable

Door coupling handle/drive Red/yellow, padlockable

Moulded case circuit-breakers, switch-disconnectors Accessories, data management interface


Moeller SK0211-1149GB Description For use with Part number

63

Shafts Mounting depth F 400 mm Mounting depth F 600 mm Mounting depth F 400 mm Mounting depth F 600 mm Mounting spacer Grid depth 17.5 mm (pack of 4) NZM1, NZM2, PN1, PN2, N1, N2 NZM1/2-XAB NZM1, NZM2, PN1, PN2, N1, N2 NZM1, NZM2, PN1, PN2, N1, N2 NZM3, NZM4 NZM3, NZM4 NZM1/2-XV4 NZM1/2-XV6 NZM3/4-XV4 NZM3/4-XV6

Clip plate For top-hat DIN rail 35 mm Data management interface (DMI) DMI unit Electronic trip devices only NZM1, PN1, N1 NZM... NZM1-XC35 NZM-XDMI612

Software kit Power supply Cable Terminal covers

To link between DMI and NZM... IP4X, 3-pole

NZM..., DMI DMI NZM..., DMI NZM1, PN1, N1 NZM2, PN2, N2

NZM-XPC-KIT EASY400-POW NZM-XDMI-CAB NZM1-XKSA NZM2-XKSA

Moulded case circuit-breakers NZM switch-disconnectors PN, N

64

Part number list

Moeller SK0211-1149GB Part no.


....DILE...

Device
Auxiliary contact modules Trip-indicating auxiliary contacts Padockable rotary handle Shunt trips Instruction manual Insulated enclosures, IP65 Insulated enclosures for PKZM01 Insulated enclosures for PKZM0 Current limiters

Page
26, 28 50 51 50 23 42 49 51 51

Part no.
M22S-ST... M22-TC M22-T... M22-W... M22-WJ... M22-W(R)LK... M22-WRS M22-XAK... M22-XAM... M22-XBK1 M22-XCK... M22-XC... M22-XD... M22-XST M22-X... MFD-80... MFD-AC... MFD-CP4... MFD-CP8... MFD-... MFD-TS-144 MVDILE

Device
Complete legend plates, IP66 Telescopic mounting clip Actuator diaphragms for IP67, IP69K, silicone Selector switch actuators, rotary button, thumb grip Joystick, 4 positions Illuminated selector switch actuators, thumb grip, IP66, spring-return or stay-put Pushbutton stations Diameter = 90 mm Buzzer for acoustic indicator Diameter = 60 mm Joysticks, 4 positions Set of coding adapters Button plates for pushbutton actuators, flush or extended Legend holder without label, IP66 Emergency-Stop labels, IP66 Displays Power supply/CPU IP 65, display repeater Power supply, CPU I/0-modules Mounting rail Mechanical interlocks Main switch for manual operation, 3-pole Auxiliary contacts Neutral poles Mounting spacer Shafts Shunt trips Clip plate Rotary handle/drive Auxiliary contacts Covers Door coupling handle/drive Undervoltage trips Shunt trips Auxiliary contacts Shafts Thermomagnetic trip for system/cable protection Electronic , 3pole, 50kA Data Management Interface (DMI Module) Diagnostics and parameterization software (in situ)

Page
11 10 10 6 6 7 6 11 10 11 6 6 12 11 11 22 22 23 22 22 23 28 61 50 45 63 63 62 63 62 62 63 62 62 62 62 63 60 60 63 63

A
AGM2... A-PKZ0 A-PKZO... AWB2528-...

C
CI-K-... CI-PKZ01... CI-PKZ0... CL-PKZ0

Index

D
D4E... DE5-CBL-1M0-ICL DE5-KEY-RO3 DE5-LZ... DE5-NET-DP DE6-LZ3-... DEX-CBL-2M0-PC DF... DILA-... DILA-XHI... DILEM... DILER-... DILET... DILM...-XHI... DILM12-... DILM...-XMV DILM...-XP1 DILM...-XRL DILM...XS1 DILM12-XSL DILM... DILM...-XMV DE6-LZ3-... DS4...H DS4...M DS4...MX... Compact DOL, insulated enclosures 35 Cable for display unit 39 Remote display unit 39 EMC-filters 39 PROFIBUS interface 39 EMC-filters 39 Cable for PC-connection 39 Variable speed drives, DF5, DF6 38 Contactor relays 27 Auxiliary contact modules 27 Mini contactors 28 Mini contactor relays 26 Electronic timing relays 24 Auxiliary contact modules 32 Contactors 29 Mechanical interlocks 33 Paralleling links 32 Reversing wiring links 32 Star points 33 Star-delta wiring links 32 Contactors 29, 30, 31 Mechanical interlocks 33 Star-delta wiring links 32 Single-phase semiconductor contactors 40 Three-phase semiconductor contactors, soft starters 40 Three-phase soft starters 41 Coupling unit Power supplies Technical data Power supplies Standalone base units (easy 500) Expansion units (for easy 700, easy 800) Expandable base units (easy 700) Expandable, networkable base units (easy800) Memory modules Cable for EASY-NET connnection Plug for EASY-NET bus termination PC connection cable Software Insulated enclosures for PKZM01, 02, 03, 04, 05 Electronic timing relays Foot and palm switches Industrial miniature circuit-breakers Shunt trips Trip-indicating auxiliary contact Busbar tag shrouds Auxiliary contact Commoning busbars with fork connectors 1 make, 1 break Door coupling rotary handle Basic units for position switches IP66; operating point electronically adjustable Basic units for position switches Operating heads for position switches Operating heads for position switches Fixing adapters Compact acoustic indicator Blanking plug Pushbutton, 4-way Pushbutton actuators, flush Double actuators Pushbutton stations Pushbutton actuators, extended Illuminated pushbutton actuators Mushroom actuators Flush mounting plates Surface mounting enclosures Pushbutton stations Top-hat rail adapter Contact blocks Indicator lights, flush LED elements with screw terminals Indicator lights, extended Fixing adapter Combination box spanner Sealable shroud, IP65 Emergency-Stop actuators Pushbutton stations Potentiometers Legend holder without label 23 23 21 23, 63 20 21 21 21, 23 23 23 23 23 23 49 24 9 54, 55 58 58 58 58 58 45 51 17 17 17 18 18 7 10 10 5 4, 9 5 4 4 5 5 8 8 9 10 7, 62 7 8 7 17 10 5 5 9 9 11

N
N... NHI... N-P... NZM1/2-XAB NZM...-XV NZM...-XA... NZM1-XC35 NZM...-XDV NZM...-XHIV NZM...-XKSA NZM...-XTVDV... NZM...-XU... NZM...-XA... NZM...-XHIV NZM...-XV NZMB..., NZMN... NZMN...-VE-... NZM-XDMI... NZM-XPC-KIT

E
EASY200-EASY EASY...-POW EASY202-RE EASY...-POW EASY5... EASY6... EASY7... EASY8... EASY-M... EASY-NT-30 EASY-NT-R EASY...-PC-CAB EASY-SOFT... E-PKZ01... ETR4...

P
P.../EA/SVB P1.../SS.../SVB P.../ST1/SVB P.../V/SVB P.../I.../SVB P3.../SS.../SVB PFIM... PKNM... PKZM0... PKZM01... PKZM0-XD... PKZM4... PLSM... PN... RCDILE... RH-PKZ0 Flush mounting 45 Stainless steel, enclosed isolators 45 Sheet steel, enclosed isolators 45 Rear mount, door interlock, padlockable handle 45 Insulated, enclosed isolators 44 Stainless steel, enclosed isolators 45 Standard AC residual current devices 57 Combined RCD/MCB devices (RCBO), single-phase and neutral 57 Rotary handle type PKZM0 49 Pushbutton type PKZM01 49 Direct connection between PKZM0 and contactors 33, 51 Rotary handle type PKZM4 50 Miniature circuit breakers 56 Main switch for manual operation, 3-pole 61 RC suppressor 28 Door coupling rotary handle 51 Acoustic indicator modules Base module Stand with spacer Strobe light module Fixing bracket Set of gaskets Continuous light modules, filament lamps Multiple LED Time Switches, analog Control switches, door mounting, IP65 Door mount, padlockable handle Insulated, enclosed isolators Rear mount, door interlock, padlockable handle Stainless steel, enclosed isolators Insulated, enclosed isolators Rear mount, door interlock, padlockable handle Undervoltage trips Varistor suppressors Early-make auxiliary contacts Direct-on-line starters (DOL) Star-delta starters Busbar end caps Shaft extensions Overload relays Free-standing overload relay adapter Busbar combs with fork connectors Modular contactors Sealing covers Interlock extensions 15 14 15 15 15 15 14, 15 15 57 46 45 44 45 45 44 45 50 28 50 35 35 58 45 34 34 58 57 58 45

F
FAK-R... FAZ-... FAZ-XAA... FAZ-XAM002 FAZ-XBS FAZ-XHI11 FAZ-XIS... HI11-P1/P3... H-PKZ0

S
SL-A SL-B SL-F... SL-FL... SL-FW SL-IP65 SL-L... SL-LED... SU...

L
LS... LSE-... LSM... LSM-X... LS-X...

T
T0.../E T... T... T...102/V/SVB T0-2-1/SS1/SVB T... T...102/V/SVB

M
M22A... M22-AMC M22-B M22-D4-S M22-D... M22-DDL... M22-D-G-X1... M22-DH... M22-DL... M22-DP... M22-E... M22-I... M22-I...-M... M22-IVS M22-K... M22-L... M22-LED... M22-LH... M22-LS M22-MS M22-PL-PV M22P... M22PV/KC... M22-R... M22S-ST...X

U
U-PKZ0...

V
VGDILE... VHI20-PKZ0

X
XD... XSD...

Z
Z-AK-.../2+3P ZAV... ZB..., ZE... ZB...-XEZ Z-GV... Z-SCH... Z-SCHAK-...TE ZVV...

Technical Data Rated currents of three-phase motors (guidelines for squirrel-cage motors)

Minimum fuse size for the protection of three-phase motors The maximum size is governed by the requirements of the associated switchgear or overload relay

Motor rating

230 V
Rated motor current Fuse Starting direct A 2 2 4 4 4 6 10 10 10 16 20 25 32 32 50 80 100 125 125 200 200 250 250 315 400 500 630 630 800 Y/' A 2 2 2 4 4 4 6 10 10 16 16 25 32 40 63 80 80 100 125 160 200 250 315 400 500 630 630

400 V
Rated motor current A 0.21 0.31 0.41 0.6 0.8 1.1 1.5 1.9 2.6 3.6 5 6.6 8.5 11.3 15.2 21.7 29.3 36 41 55 68 81 99 134 161 196 231 279 349 437 544 683 769 Fuse Starting direct A 2 2 2 2 4 4 4 6 6 6 10 16 20 25 32 40 63 63 80 100 125 160 200 200 250 315 400 400 500 630 800 1000 1000 Y/' A 2 2 2 4 4 4 6 10 10 16 16 25 32 40 50 63 80 100 125 160 200 200 250 315 400 500 630 800 800

500 V
Rated motor current A 0.17 0.25 0.33 0.48 0.7 0.9 1.2 1.5 2.1 2.9 4 5.3 6.8 9 12.1 17.4 23.4 28.9 33 44 54 65 79 107 129 157 184 224 279 349 436 547 615 Fuse Starting direct A 2 2 2 2 2 2 4 4 6 6 10 16 16 20 25 32 50 50 63 80 100 125 160 200 200 250 250 315 400 500 630 800 800 Y/' A 2 2 2 4 4 4 6 10 16 16 20 25 32 32 50 63 80 80 125 160 160 200 250 315 400 500 630 630

690 V
Rated motor current A 0.12 0.18 0.24 0.35 0.5 0.7 0.9 1.1 1.5 2.1 2.9 3.8 4.9 6.5 8.8 12.6 17 20.9 23.8 32 39 47 58 78 93 114 134 162 202 253 316 396 446 491 550 618 Fuse Starting direct A 2 2 2 2 2 2 4 4 4 6 10 10 16 16 20 25 32 32 50 63 80 80 100 160 160 200 250 250 315 400 500 630 630 630 800 800 Y/' A 2 2 2 4 4 4 6 10 10 16 20 25 25 32 50 63 63 100 100 125 160 200 250 315 400 400 630 630 630 630

kW 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 400 450 500 560 630 Notes

cos M 0.7 0.7 0.7 0.7 0.7 0.72 0.75 0.79 0.81 0.81 0.81 0.82 0.82 0.82 0.82 0.84 0.84 0.84 0.84 0.85 0.86 0.86 0.86 0.86 0.86 0.86 0.87 0.87 0.87 0.87 0.87 0.88 0.88 0.88 0.88 0.88

K (%) 58 60 60 62 62 66 69 74 74 74 78 80 83 86 87 87 88 88 92 92 92 93 93 94 94 94 95 95 95 95 96 96 96 97 97 97

A 0.37 0.54 0.72 1.04 1.4 2 2.7 3.2 4.6 6.3 8.7 11.5 14.8 19.6 26.4 38 51 63 71 96 117 141 173 233 279 342 401 486 607

The rated motor currents apply to normal, internally-ventilated and enclosed fan-cooled three-phase motors at 1500 rpm. D.O.L. starting: Maximum starting current 6 u rated motor current. Maximum starting time 5 seconds. Y/'starting: Maximum starting current 2 u rated motor current. Maximum starting time 15 seconds. Set the overload relay in the phase lead to 0.58 u rated motor current.

Rated fuse currents for Y/'starting also apply to three-phase motors with slip-ring rotors. Use a larger fuse if the rated current or starting current is higher and/ or if the starting time is longer. The table applies to slow or gL fuses (VDE 0636) LV h.b.c. fuses with aM characteristics, select fuse size to match rated current.

Still not found what you are looking for? Please visit www.moeller.co.uk or call our literature line on 01296 310321 and ask for one of the following

Moeller Electric Limited P. O. Box 35, Gatehouse Close Aylesbury Buckinghamshire HP19 8DH www.moeller.co.uk
Direct Sales Ordering Tel: 01296 397400 Fax: 01296 392413 Email: sales@moeller.co.uk Technical Support Tel: 01296 310323 Fax: 01296 392413 Email: support@moeller.co.uk

Main Catalogue Industrial Switchgear

Issued by Moeller GmbH Hein-Moeller-Str. 7-11 D-53115 Bonn 2005 by Moeller GmbH Subject to alterations SK0211-1149GB MDS/Doku/DM 05/05 Printed in the Federal Republic of Germany (05/05) Article No.: 100048

Main Catalogue Automation Systems