Beruflich Dokumente
Kultur Dokumente
Address
01/12/12
Item #
#1
Qty. 1
Description
#2
#3 #4 #5 #6 #7
3 1 1 1 1
Caldero acuatubular de agua caliente Marca Cleaver Brooks Modelo: FLX-700-900-200HW Voltaje (460/3/60) Product Type: Elite Input: 9,000,000 Btu/Hr Output: 7200000 Btu/hr (215 HP) Weight: 8500 lbs. Design Pressure: 200# Hot Water psig Operating Pressure: 72 psig Operating Temperature: 293 Deg. F Return Water Temp: 221 Deg. F Fuel Series: 700 - Natural Gas Gas Pressure: 120 Inches w.c. Voltage: 460/3/60 Standard Main LWCO: Warrick 26/E1 on/off Probe Standard Auxiliary LWCO: None Insurance Requirements: None Selected Configuration Check: Standard Selections Product Pricing Basis: Jun11 Price Book in use based on 01/12/2012 effective date for this product configuration. (1.0208 exchange rate in effect for USD/CAD conversions.) Pricing valid for 30 days. Expiration: 2/11/2012. (5) FLX Installation/FLX 1.5-9.0 BTU/HR/Profire V Series Burners///FARC System Display////CB780E/784E Burner Control & Operating Info// Design Pressure - 200# Hot Water Safety Valve Setting - 100lb HW Hot Water High Temperature Safety Valves Emission Level - 60 ppm NG and/or 140 ppm oil
Rev 9/11 C9-1881A
#8 #9 # 10 # 11 # 12 # 13 # 14 # 15 # 16 # 17 # 18 # 19 # 20 # 21 # 22 # 23 # 24 # 25 # 26 # 27 # 28 # 29 # 30 # 31 # 32 # 33
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Burner Turndown: 8:1 Burner Selection - Standard: CB Profire PF-LNVG-90/F, 10 hp, frame size 3 Gas Valve Description - Dual Motorized with 1 POC 2.5 in. Gas Train Size Selection Regulator Selection: 210G 3 Phase Motor - STD Hot Water Outlet Change - 6"/Flange 150 lb to 8"/Flanged 150lb. F.F. Hot Water Return Connection Change - 6"/Flange 150lb to 8"/Flanged 150lb. F.F. Blowdown/Drain Connection: 2in - NPT Pressure Gauge - 3-1/2" Dial, 0-300 psig Temperature Gauge - 3" Dial, 50-450 Deg F Insulated Downcomer - Standard Combustion Safeguard - CB-780E, UV Scan Note: CB-780E Standard Comb Safeguard Control for Hawk Package - Confirm Selection Parallel Positioning System - FARC System Incl. (Low Nox) - No Hawk FGR Actuator Temperature or Pressure Controler for FARC System: UDC 2500 Temp, panel mounted System Pump Interlock - Relay and Terminals System Flow Switch (Shipped Loose) Burner Hinge - Standard Control Panel Enclosure - NEMA 1A Key Lock Panel - Standard Control Circuit Transformer - Standard Fan Motor Fuse Protection (460/3/60) Submittals - Dimensional Diagram (Model FLX) Submittals - Wiring Diagram (Model FLX) Submittals - Test Fire Report (Model FLX)
Total: $94,790.00
PRECIOS EN DOLARES AMERICANOS NO INCLUYE EL IGV ENTREGA 14 SEMANAS DE COLOCADO EL ADELANTO FORMA DE PAGO 50% CON LA ORDEN DE COMPRA , SALDO CONTRAENTREGA CALDERA PUESTA EN SUS ALMACENES EN LIMA SOBRE PLATAFORMA DEL CAMION.
PRICE ADJUSTMENT all prices in this proposal are subject to price adjustment in accordance with Cleaver-Brooks Price Adjustment Policy
Cleaver-Brooks, Inc. offers to furnish the Equipment described herein for the purchase price noted, exclusive of all taxes. Prices quoted are firm for 30 days from the date of Proposal subject to adjustment as noted. Standard Cleaver-Brooks payment terms are unconditional net 30 from the date of readiness for shipment or unless otherwise specified in this proposal. Cleaver-Brooks will review your order prior to acceptance (and acknowledgment) and order entry. Until acceptance and order entry, the Equipment is subject to prior sale. Incorporation of technical specifications or requirements different from or additional to the Cleaver-Brooks proposal and not previously reviewed by Cleaver-Brooks will extend the order review process and may postpone or prevent acceptance of your order and order entry. Cleaver-Brooks does not agree and will not agree to INCIDENTAL, CONSEQUENTIAL AND LIQUIDATED DAMAGES OR IMPLIED WARRANTIES. Cleaver-Brooks does not agree and will not agree to, unless specifically set forth in an agreement in writing having an authorized Cleaver-Brooks signature: (1) terms and conditions in your order that are different from or additional to those of Cleaver-Brooks' Proposal; (2) technical specifications, technical requirements or descriptions of the goods and services ordered that are different from or additional to those of Cleaver-Brooks' Proposal; or (3) generalized expressions such as "per plans and specs."
THE TERMS AND CONDITIONS OF SALE ON THE REVERSE SIDE ARE PART OF THIS PROPOSAL Rev 9/11 C9-1881A
Please return one signed copy of this proposal, or submit your purchase order addressed to Cleaver-Brooks, Inc., in care of your Cleaver-Brooks Sales Representative referencing this Proposal by number and date.
by one arbitrator in AAAs Case Management Center offices located approximately half way between the home office locations of the parties, unless otherwise agreed, and judgment on the award rendered by the arbitrator may be entered in any court having jurisdiction thereof.